Loading...
HomeMy WebLinkAboutPLANS PV Solar 800 Big Thompson Ave A 2020-04-21Cover Sheet PV 0 No.Date Description Revision Schedule Building and Code Info: Permitting Jurisdiction: Town of Estes Park Wind Speed: 175 mphVult Roof Snow Load: 66 psf IBC Code Cycle: 2015 IRC Code Cycle: 2015 NEC Code Cycle: 2017 Layout 1: Tilt: o Azimuth:o # of Panels 57 Project Info: System Size:92.84 kW Panel Model:(211) SPR-A21-440-COM Module Dimension:72.2" x 40" x 1.57" Racking Model:Iron Ridge Attachments:ZillaMount Double Stud Inverter Model:(2) SE5000H-US (4) SE10000H-US (2) SE11400H-US Optimizer: (211) P505 Roof Type:Comp Shingle Attic Space:Yes Utility:Estes Park System AC Voltage:120/240 VAC Building Voltage:120/240 VAC Contacts: Customer: Subs: Sheet Index: PV 0 Cover Sheet PV 1 Site Plan PV 2 Attachment Detail PV 3.1 PV Layout 1 PV 3.2 PV Layout 2 PV 3.3 PV Layout 3 PV 4 String Map PV E1.1 Building A Line Diagram PV E1.2 Building B Line Diagram PV E1.3 Building C Line Diagram PV E2.1 Building A Electric Calcs PV E2.2 Building B Electric Calcs PV E2.3 Building C Electric Calcs Notes: Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 Layout 2: Tilt: o Azimuth:o # of Panels 66 Layout 3: Tilt: o Azimuth:o # of Panels 88 Building B Building C Building A Site Plan PV 1 No.Date Description 1 2/24/2020 Revision Schedule Notes: System Size: 92.84 kW Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Site Plan Scale:1 custom 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 12" OSB Decking Asphalt Shingle Roofing Zilla Double Stud Truss Top Chord PV Module IronRidge with UFO Clip L-Foot Connection: 5/16" Stainless Steel Hardware 5 16" x 4" Lag (x2) Attachment Detail PV 2.1 No. Date Description Revision Schedule 1501 Lee Hill Drive #24 Boulder, CO 80304 Phone: (303) 443-0115 Fax: (303) 443-2173 Notes:. -2 screws in rafters Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Attachment Detail Scale:2.1 2 193/256" = 1' 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 168" 168" 154" 154" 1535 8" 1495 8" 97'-6 12" 94'-2 14" 12'-0 12" 3' 4'-10 12" 1'-6" 14' Iron Ridge 17' Iron Ridge Layout 1 PV 3.1 No.Date Description Revision Schedule Notes: -PV Array 1 is on Building A Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Attachment Spans Roof/Wall Zone Length = 3' Zone Half Tributary (in) Full Tributary (in) 1 48 NA 2 48 NA 3 48 NA 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 Layout Scale:3.1 Custom 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 168" 168" 149" 149" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 168" 168" 149" 149" 111' 12'-0 12" 1'-312" 3' 14' Iron Ridge 17' Iron Ridge Layout 2 PV 3.2 No.Date Description Revision Schedule Notes: -PV Array 2 is on Building B Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Attachment Spans Roof/Wall Zone Length = 3' Zone Half Tributary (in) Full Tributary (in) 1 48 NA 2 48 NA 3 48 NA 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 Layout Scale:3.2 0.006191 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 149" 149" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 204" 149" 149" 148'-0 14" 12'-012" 1'-6"6'-9"3' 14' Iron Ridge 17' Iron Ridge Layout 3 PV 3.3 No.Date Description Revision Schedule Notes: -PV Array 3 is on Building C -PV array area is 33% of the building plan area. Per IFC 1204.2.1.3 we are able to have a ridge setback no less than 18 inches Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Attachment Spans Roof/Wall Zone Length = 3' Zone Half Tributary (in) Full Tributary (in) 1 48 NA 2 48 NA 3 48 NA 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 Array 2 10 kW Inverter C (3 strings of 11modules) [7,8,9] 10 kW Inverter D (3 strings of 11 modules) [10,11,12] Array 1 Array 3 5 kW Inverter G (2 strings of 7 modules) [19,20] 5 kW Inverter H (2 strings of 7 modules) [21,22] 10 kW Inverter E (3 strings of 10 modules) [13,14,15] 10 kW Inverter F (3 strings of 10 modules) [16,17,18] 7 8 9 10 11 12 13 14 15 16 17 1819202122 11.4 kW Inverter A (3 string of 9 modules) [1,2,3] 11.4 kW Inverter B (2 string of 9 modules) [4,5] (1 String of 12 modules) [6] 1 2 3 456 54 W Dane St. Unit F Beverly, MA 01915 Phone: (978) 9984079 Fax: (978) 969-3410 Project Information Notes:. -(6) module string minimum -(13) module string maximum Sheet No. Date Drafter Engineer Review Scale 3/12/2020 KRW 1" = 19.7492' String Map PV4 Discovery Lodge 800 Big Thompson Ave. Estes Park, CO 80517 Array 1: 57 Modules 1 Transition Box 1 2 2 5 MHP 3 6 ROOF EXTERIOR WALL BUILDING A 3 1 2 3 60A, 2P 60A, 2P 4 4 3 200A, 2P 1 2 2 5 M 11.4 kW Inverter A: 2 strings of 9 1 string of 12 11.4 kW Inverter B: 3 strings of 9 Line Diagram Building A PV E1.1 No. Date Description Revision Schedule Notes: Design based off of 2017 NEC System Size = 25.08 kW Discovery Lodge 800 Big Thompson Ave Estes Park, CO 80517 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 System Information TAG Equipment Description 1 PV Module (N) x57 SPR-A21-440-COM Vmp 43.4 V, Voc 51.6 V Imp 10.2 A, Isc 10.9 A 2 Optimizer (N) x57 P505 3 Inverter (N) x2 Solar Edge SE14000H-US 500 V DC, 240 V AC 99% CEC, 47.5 FLA 4 Combiner Panel (N) 200 A MLO, 240 VAC 5 AC Disconnect (N)200 A, Fused @ 125A, knife blade, 2P, 240 VAC 6 Main Service Panel (E)200A, 200 A Main, 240 VAC Wire/Conduite Schedule TAG Description Conduit type/size Current carrying conductor type/size Neutral conductor type/size Grounding conductor type/size ~1-w ay length (ft) Notes 1 PV Array to Transition Box NA 12 x #10 PV x 1 x #10 Bare Cu 20 2 Transition Box to Inverter 1" EMT 12 x #12 THWN-2 x 1 x #12 THWN-2 30 3 Inverter to Combiner Panel 3 4" EMT 2 x #6THWN-2 1 x #6 THWN-2 1 x #10 THWN-2 10 4 Combiner Panel to AC Disconnect 1 1/2" EMT 2 x #1THWN-2 1 x #1 THWN-2 1 x #6 THWN-2 10 5 AC Disconnect to MSP 1 1/2" EMT 2 x #1THWN-2 1 x #1 THWN-2 x 10 Array 2: 6 strings of 11 modules 1 Transition Box 1 2 2b 7 M MSP 3 8 BUILDING B ROOF EXTERIOR WALL BUILDING B 3 3 2 1 4 30A, 2P 60A, 2P 5 5 4 200A, 2P 1a 2 2 7 3 2 1 4 4 60A, 2P 6 6 UTILITY PEDESTAL BUILDING C ROOF Array 3: 2 strings of 7 modules 1 Transition Box 1b 2 2 2a 5 kW Inverter G: 2 strings of 7 10 kW Inverter C: 3 strings of 11 10 kW Inverter D: 3 strings of 11 Line Diagram Building B PV E1.2 No. Date Description Revision Schedule Notes: Design based off of 2017 NEC System Size = 35.2 kW Discovery Lodge 800 Big Thompson Ave Estes Park, CO 80517 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 System Information TAG Equipment Description 1 PV Module (N) x80 SPR-A21-440-COM Vmp 43.4 V, Voc 51.6 V Imp 10.2 A, Isc 10.9 A 2 Optimizer (N) x80 P505 3 Inverter (N) x1 Solar Edge SE5000H-US 500 V DC, 240 V AC 99% CEC, 21 FLA 4 Inverter (N) x2 Solar Edge SE10000H-US 500 V DC, 240 V AC 99% CEC, 42 FLA 5 Combiner Panel (N) 200 A MLO, 240 VAC 6 AC Disconnect (N)150 A, Non-Fused, knife blade, 2P, 240 VAC 7 AC Disconnect (N)150 A, Fused @150A, knife blade, 2P, 240 VAC 8 Main Service Panel (E)200 A, 200 A Main, 240 VAC Wire/Conduite Schedule TAG Description Conduit type/siz e Current carrying conductor type/size Neutral conductor type/size Grounding conductor type/size ~1-w ay length (ft) Notes 1a PV Array to Transition Box NA 12 x #10 PV x 1 x #10 Bare Cu 20 1b PV Array to Transition Box NA 4 x #10 PV x 1 x #10 Bare Cu 20 2a Transition Box to transition box 3 4" EMT 4 x #12 THWN-2 x 1 x #12 THWN-2 30 2b Transition Box to Inverter 1" EMT 16 x #12 THWN-2 x 1 x #12 THWN-2 30 3 Inverter to Combiner Panel 3 4" EMT 2 x #10THWN-2 1 x #10 THWN-2 1 x #10 THWN-2 10 4 Inverter to Combiner Panel 3 4" EMT 2 x #6THWN-2 1 x #6 THWN-2 1 x #10 THWN-2 10 5 Combiner Panel to AC Disconnect 2" EMT 2 x #1/0THWN-2 1 x #1/0 THWN-2 1 x #6 THWN-2 10 6 AC Disconnect to AC Disconnect 2" PVC 2 x #1/0THWN-2 1 x #1/0 THWN-2 1 x #6 THWN-2 50 7 AC Disconnect to MSP 2" EMT 2 x #1/0THWN-2 1 x #1/0 THWN-2 X 10 Array 3: 6 strings of 10 modules 2 strings of 7 modules 1 Transition Box 1 2 2 7 M MSP 3 8 BUILDING C ROOF EXTERIOR WALL BUILDING B 3 1 2 4 30A, 2P 60A, 2P 5 5 4 200A, 2P 1 2 2 7 1 2 4 4 60A, 2P 6 6 UTILITY PEDESTAL 5 kW Inverter H: 2 strings of 7 10 kW Inverter E: 3 strings of 10 10 kW Inverter F: 3 strings of 10 Line Diagram Building C PV E1.3 No. Date Description Revision Schedule Notes: Design based off of 2017 NEC System Size = 32.56 kW Discovery Lodge 800 Big Thompson Ave Estes Park, CO 80517 1501 Lee Hill Dr. #24 Boulder, CO 80301 Phone: 303.443.0115 Fax: 303.443.2173 System Information TAG Equipment Description 1 PV Module (N) x74 SPR-A21-440-COM Vmp 43.4 V, Voc 51.6 V Imp 10.2 A, Isc 10.9 A 2 Optimizer (N) x74 P505 3 Inverter (N) x1 Solar Edge SE5000H-US 500 V DC, 240 V AC 99% CEC, 41 FLA 4 Inverter (N) x2 Solar Edge SE10000H-US 500 V DC, 240 V AC 99% CEC, 42 FLA 5 Combiner Panel (N) 200 A MLO, 240 VAC 6 AC Disconnect (N)150 A, Non-Fused, knife blade, 2P, 240 VAC 7 AC Disconnect (N)150 A, Fused @150A, knife blade, 2P, 240 VAC 8 Main Service Panel (E)200 A, 200 A Main, 240 VAC Wire/Conduite Schedule TAG Description Conduit type/siz e Current carrying conductor type/size Neutral conductor type/size Grounding conductor type/size ~1-w ay length (ft) Notes 1 PV Array to Transition Box NA 16 x #10 PV x 1 x #10 Bare Cu 20 2 Transition Box to Inverter 1" EMT 16 x #12 THWN-2 x 1 x #12 THWN-2 130 3 Inverter to Combiner Panel 3 4" EMT 2 x #10THWN-2 1 x #10 THWN-2 1 x #10 THWN-2 10 4 Inverter to Combiner Panel 3 4" EMT 2 x #6THWN-2 1 x #6 THWN-2 1 x #10 THWN-2 10 5 Combiner Panel to AC Disconnect 2" EMT 2 x #1/0THWN-2 1 x #1/0 THWN-2 1 x #6 THWN-2 10 6 AC Disconnect to AC Disconnect 2" PVC 2 x #1/0THWN-2 1 x #1/0 THWN-2 1 x #6 THWN-2 50 7 AC Disconnect to MSP 2" EMT 2 x #1/0THWN-2 1 x #1/0 THWN-2 X 10 PV E2 Electrical Calcs Discovery Building A PV System Notes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 2 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 47.5 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer No Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 2 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 47.5 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer No Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes Module Specs SPR A21-440-COM Inverter Specs SE - 11400h-US String Specs 80 15 80 Array Specs 240 3 13.2 Inverter Specs SPR A21-440-COM SE - 11400h-US Module Specs 240 Array SpecsString Specs SE - 11400h-US 15 9 9 3 11.88 27 500 9 30 SE - 11400h-US 9 9 12 500 PV E2 Electrical Calcs PV source Ciruit *AWG #10 PV Listed per NEC 690.31(B) De-rated Ampacity of the conductor (Amps): DC Circuit 690.8(A)NEC Table 310.15(B)(2)(a) #12 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT Ambient Temp (°F)132-140 Maximum Circuit Current: Single String-PV Source Circuit 690.8(A) (Module Isc)10.9 x (Design factor for environmental condtions)1.25 =13.63 Amps 690.9(B) 690.8(B)(1)13.63 x (Continuous Duty)1.25 =17.03 Amps Fuse (Amps):15 690.8(B)(2)13.63 / (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) 1 /De-rate for ambient Temp:0.71 =19.2 Amps Wire Ampacity per NEC 310.15(B)( 30 Maximum Inverter Output Current: NEC 690.8 Inverter Output 47.5 x 1.25 =59.375 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #6 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)75 x 1 x De-rate for ambient Temp: 0.91 =68.25 Maximum Inverter Output Current: NEC 690.8 Inverter Output 47.5 x 1.25 =59.375 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #6 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)75 x 1 x De-rate for ambient Temp: 0.91 =68.25 Maximum Inverter Output Current: NEC 690.8 Inverter Output 95 x 1.25 =118.75 125 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #1 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)145 x 1 x De-rate for ambient Temp: 0.91 =131.95 (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Ambient Temp (°F) NEC Table 310.15(B)(2)(a) Continuous Duty Breaker/Fuse (Amps) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) PV E2 Electrical Calcs Discovery Building B PV System Notes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 4 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect Yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 21 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer yes Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 2 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 42 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer yes Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes Module Specs SPR A21-440-COM Inverter Specs SE-10000H-US String Specs 80 15 80 Array Specs 240 3 14.52 Inverter Specs SPR A21-440-COM SE - 5000H-US Module Specs 240 Array SpecsString Specs SE - 5000H-US 15 7 7 2 6.16 14 500 0 33 SE-10000H-US 11 11 11 500 PV E2 Electrical Calcs PV source Ciruit *AWG #10 PV Listed per NEC 690.31(B) De-rated Ampacity of the conductor (Amps): DC Circuit 690.8(A)NEC Table 310.15(B)(2)(a) #12 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT Ambient Temp (°F)132-140 Maximum Circuit Current: Single String-PV Source Circuit 690.8(A) (Module Isc)10.9 x (Design factor for environmental condtions)1.25 =13.63 Amps 690.9(B) 690.8(B)(1)13.63 x (Continuous Duty)1.25 =17.03 Amps Fuse (Amps):15 690.8(B)(2)13.63 / (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) 1 /De-rate for ambient Temp:0.71 =19.2 Amps Wire Ampacity per NEC 310.15(B)( 30 Maximum Inverter Output Current: NEC 690.8 Inverter Output 21 x 1.25 =26.25 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #10 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)40 x 1 x De-rate for ambient Temp: 0.91 =36.4 Maximum Inverter Output Current: NEC 690.8 Inverter Output 42 x 1.25 =52.5 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #6 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)75 x 1 x De-rate for ambient Temp: 0.91 =68.25 Maximum Inverter Output Current: NEC 690.8 Inverter Output 105 x 1.25 =131.25 150 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit 1/0 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)170 x 1 x De-rate for ambient Temp: 0.91 =154.7 (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Ambient Temp (°F) NEC Table 310.15(B)(2)(a) Continuous Duty Breaker/Fuse (Amps) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) PV E2 Electrical Calcs Discovery Building C PV System Notes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 4 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect Yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 21 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer yes Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes SPR-327-WHT E20 Service Voltage(V) Peak Power 440 Input Voltage MPPT Range 0-500 Modules in String 1 # of Strings Vmp 43.4 Inputs 2 Modules in String 2 Peak Power(kW) Imp 10.2 Intigrated DC Disconnect yes Modules in String 3 # of Modules Voc 51.6 Nominal Voltage 240 Maximum System Voltage Isc 10.9 Nominal Output Current 42 Max Output Current Vcoeff 0.1674 Integrated Isolation Transformer yes Max Voc Input Series Fuse 15 Integrated Ground Fault Protection yes 500 30 SE-10000H-US 10 10 10 15 7 7 2 6.16 14 500 0 Inverter Specs SPR A21-440-COM SE - 5000H-US Module Specs 240 Array SpecsString Specs SE - 5000H-US 80 15 80 Array Specs 240 3 13.2 Module Specs SPR A21-440-COM Inverter Specs SE-10000H-US String Specs PV E2 Electrical Calcs PV source Ciruit *AWG #10 PV Listed per NEC 690.31(B) De-rated Ampacity of the conductor (Amps): DC Circuit 690.8(A)NEC Table 310.15(B)(2)(a) #12 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT Ambient Temp (°F)132-140 Maximum Circuit Current: Single String-PV Source Circuit 690.8(A) (Module Isc)10.9 x (Design factor for environmental condtions)1.25 =13.63 Amps 690.9(B) 690.8(B)(1)13.63 x (Continuous Duty)1.25 =17.03 Amps Fuse (Amps):15 690.8(B)(2)13.63 / (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) 1 /De-rate for ambient Temp:0.71 =19.2 Amps Wire Ampacity per NEC 310.15(B)( 30 Maximum Inverter Output Current: NEC 690.8 Inverter Output 21 x 1.25 =26.25 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #10 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)40 x 1 x De-rate for ambient Temp: 0.91 =36.4 Maximum Inverter Output Current: NEC 690.8 Inverter Output 42 x 1.25 =52.5 60 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit #6 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:3/4" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)75 x 1 x De-rate for ambient Temp: 0.91 =68.25 Maximum Inverter Output Current: NEC 690.8 Inverter Output 105 x 1.25 =131.25 150 De-rated Ampacity of the conductor (Amps):Inverter Output Circuit 1/0 THWN-2 at 90° C Number of Current Carrying Conductors:1-3 Conduit Size/Type:1" EMT 96-104 Wire Ampacity per NEC 310.15(B)(16)170 x 1 x De-rate for ambient Temp: 0.91 =154.7(De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) Continuous Duty Breaker/Fuse (Amps) NEC Table 310.15(B)(2)(a) Ambient Temp (°F) (De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)) Ambient Temp (°F) NEC Table 310.15(B)(2)(a) Continuous Duty Breaker/Fuse (Amps) 1501 Lee Hill Dr. Unit 24 Boulder, CO 80304-5602 Phone: (303) 443-0115 Fax: (303) 443-2173 PV System Labeling E3 . 0 0 Additional Notes                                    SUNPOWER MAXEON SOLAR CELL TECHNOLOGY Fundamentally Different. And Better.  Most powerful cell in commercial solar2  Delivers unmatched reliability3  Patented solid metal foundation prevents breakage and corrosion As sustainable as the energy it produces.  Ranked #1 in Silicon Valley Toxics Coalition 2015 Solar Scorecard4  Contributes to more LEED categories than conventional panels5 A       430-450W Commercial A-Series Panels SunPower®Maxeon®Cell-based Solar Panels SunPower® Maxeon® cell-based panels maximize energy production and savings by combining industry-leading power, efficiency, and durability with the best warranty available in the market.1,2   Highest Power Density Available SunPower’s new Maxeon® Gen 4 cell is 65% larger than prior generations, delivering the most powerful cell and highest efficiency panel in commercial solar. The result is more power per square meter than any commercially available solar.2 A 6”5” ~65% larger Highest Lifetime Energy and Savings Designed to deliver 60% more energy in the same space over 25 years in real-world conditions like partial shade and high temperatures.2 25 - y e a r E n e r g y Y i e l d p e r W a t t Years of Operation Up to 60% More Lifetime Energy 0510152025 150% 140% 130% 120% 110% 100% 90% 80% 70% 60% Conventional Panel SunPower A-Series Panels Best Reliability, Best Warranty SunPower technology is proven to last and we stand behind our panels with the industry’s best 25-year Combined Power, Product and Service Warranty. sunpower.com    Reduced Soiling NEW drainage notch improves performance    Operating Condition And Mechanical Data Temperature −40° F to +185° F (−40° C to +85° C) Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Appearance Class A Solar Cells 72 Monocrystalline IBC cells Tempered Glass High-transmission tempered anti-reflective Junction Box IP-68, MC4 Compatible Weight 40.5 lbs (18.4 kg) Max. Load Wind: 75 psf, 3600 Pa, 367 kg/m² front & back Snow: 125 psf, 6000 Pa, 612 kg/m² front Frame Class 2 silver anodized FRAME PROFILE 4 0 m m [ 1 . 5 7 i n ] (A) Cable Length: 1320 mm [52 in] (B) Long Side: 30 mm [1.2 in] Short Side: 22 mm [0.9 in] 40 mm [1.57 in] B 1999 mm [78.7 in] 1016 mm [40.0 in] (A) Please read the safety and installation guide.                                                                                      Electrical Data SPR-A450-COM SPR-A440-COM SPR-A430-COM Nominal Power (Pnom)6 450 W 440 W 430 W Power Tolerance +5/0% +5/0% +5/0% Panel Efficiency 22.2% 21.7% 21.2% Rated Voltage (Vmpp) 44.0 V 43.4 V 42.7 V Rated Current (Impp) 10.2 A 10.2 A 10.1 A Open-Circuit Voltage (Voc) 51.9 V 51.6 V 51.2 V Short-Circuit Current (Isc) 11.0 A 10.9 A 10.9 A Max. System Voltage 1500 V UL Maximum Series Fuse 20 A Power Temp Coef. −0.26% / o C Voltage Temp Coef. −136 mV / o C Current Temp Coef. 5.7 mA / o C Tests And Certifications - Pending Standard Tests UL1703 Quality Management Certs ISO 9001:2015, ISO 14001:2015 EHS Compliance RoHS, OHSAS 18001:2007, lead free, Recycle Scheme, REACH SVHC-163 Sustainability Cradle to Cradle CertifiedTM Silver. "Declare." listed. Ammonia Test IEC 62716 Desert Test 10.1109/PVSC.2013.6744437 Salt Spray Test IEC 61701 (maximum severity) PID Test 1500 V: IEC 62804, PVEL 600 hr duration Available Listings UL 1 SunPower 450 W, 22.2% efficient, compared to a Conventional Panel on same-sized arrays (310 W, 16% efficient, approx. 2.0 m²), 4.9% more energy per watt (based on PVSyst pan files for avg US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.” PVSC 2018). 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of January 2018. 3 #1 rank in “Fraunhofer PV Durability Initiative for Solar Modules: Part 3”. PVTech Power Magazine, 2015. Campeau, Z. et al. “SunPower Module Degradation Rate,” SunPower white paper, 2013. 4 SunPower is rated #1 on Silicon Valley Toxics Coalition’s Solar Scorecard. 5 A-Series panels additionally contribute to LEED Materials and Resources credit categories. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C). NREL calibration Standard: SOMS current, LACCS FF and Voltage. See www.sunpower.com/company for more reference information. For more details, see extended datasheet: www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ©2018 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, and MAXEON are trademarks or registered trademarks of SunPower Corporation. 430-450W Commercial A-Series Panels – Preliminary datasheet   sunpower.com  532365 Rev A / LTR_US 1-800-SUNPOWER PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P370 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA - INDIA © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017 V.02. Subject to change without notice. (2) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (3) It is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string. P300 (for 60-cell mod- ules) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1)300 320 370 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatible MC4 / Amphenol AH4 MC4 Compatible Output Wire Type / Connector Double Insulated; MC4 Compatible Double Insulated; MC4 / Amphenol AH4 Double Insulated; MC4 Compatible Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P370 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)(3) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers)25 25 50 Maximum Power per String 5700 (6000 with SE7600H-US)5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes IN V E R T E R S SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA 12-25 The best choice for SolarEdge enabled systems Specifically designed to work with power optimizers Integrated arc fault protection for NEC 2011 690.11 compliance Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module-level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional – revenue grade data, ANSI C12.1 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A- US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 10000 @240V 11400 VA Max. AC Power Output 3300 4150 5400 @ 208V 5450 @240V 6000 8350 10800 @ 208V 10950 @240V 12000 VA AC Output Voltage Min.-Nom.-Max.(1) 183 - 208 - 229 Vac --3 --3 - AC Output Voltage Min.-Nom.-Max.(1) 211 - 240 - 264 Vac 3 3 3 3 3 3 3 AC Frequency Min.-Nom.-Max.(1) 59.3 - 60 - 60.5 Hz Max. Continuous Output Current 12.5 16 24 @ 208V 21 @ 240V 25 32 48 @ 208V 42 @ 240V 47.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Yes INPUT Maximum DC Power (STC)4050 5100 6750 8100 10250 13500 15350 W Transformer-less, Ungrounded Yes Max. Input Voltage 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc Max. Input Current(2) 9.5 13 16.5 @ 208V 15.5 @ 240V 18 23 33 @ 208V 30.5 @ 240V 34.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % CEC Weighted Efficiency 97.5 98 97 @ 208V 98 @ 240V 97.5 97.5 97 @ 208V 97.5 @ 240V 97.5 % Nighttime Power Consumption < 2.5 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) Revenue Grade Data, ANSI C12.1 Optional(3) Rapid Shutdown – NEC 2014 690.12 Yes STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, UL1998 , CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4” minimum / 16-6 AWG 3/4” minimum / 8-3 AWG DC input conduit size / # of strings / AWG range 3/4” minimum / 1-2 strings / 16-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 30.5 x 12.5 x 7.2 / 775 x 315 x 184 30.5 x 12.5 x 10.5 / 775 x 315 x 260 in / mm Weight with Safety Switch 51.2 / 23.2 54.7 / 24.7 88 .4 / 40.1 lb / kg Cooling Natural Convection Natural convection and internal fan (user replaceable) Fans (user replaceable) Noise < 25 < 50 dBA Min.-Max. Operating Temperature Range -13 to +140 / -25 to +60 (-40 to +60 version available(4)) ˚F / ˚C Protection Rating NEMA 3R (1) For other regional settings please contact SolarEdge support. (2) A higher current source may be used; the inverter will limit its input current to the values stated.(3) Revenue grade inverter P/N: SExxxxA-US000NNR2 (for 7600W inverter:SE7600A-US002NNR2).(4) -40 version P/N: SExxxxA-US000NNU4 (for 7600W inverter:SE7600A-US002NNU4). v092917 MADE IN USA MADE WITH RECYCLED MATERIAL © 2017 Zilla Corporation. All rights reserved. 77 Waneka Pkwy • Lafayette, CO 80026 • 720.880.6700 • fax 303.664.1268 • zillarac.com Zilla® So Simple It’s Scary SM One or more patents apply to this product including without limitation: US Pat. 8,448,405; 8,707,654; 8,689,517; 8,707,655; and/or 8,752,338. ZDSFA-15 AL / ZDSFA-15 AL BLK Zilla® Double Stud Flashing Technical Specifications Withdrawal (Pull-Out) Capacities3 (lb./in. of thread penetration) LUMBER SPECIES SPECIFIC GRAVITY 1/4” LAG SCREW 5/16” LAG SCREW 3/8” LAG SCREW Douglas Fir-Larch 0.50 252 lb./in.298 lb./in.342 lb./in. Southern Pine 0.55 291 lb./in.344 lb./in.394 lb./in. Two point installation Zilla® Flashing Zilla® Double Stud (with washer and hex head) Zilla® Base Plate (fastening hardware not included) Zilla® Double Stud Flashing Zilla® Double Stud Flashing is available in Black (ZDSFA-15 AL BLK) or custom colors1 and includes: Double Stud with Encapsulated Gland Washer, Flashing and Base Plate. Zilla® Double Stud is a 3/8”-16 x 1-1/2” stainless steel stud with 3/16” recessed hex and 1-3/8” hex aluminum nut. 1 Flashing available in Mill and custom colors, call for details and availability, minimum orders may apply; 2 Available in Stainless Steel, 10ga., call for details and availability, minimum order may apply; 3 Information for reference only. Refer to Load Data sheet for more detailed specifications. 7/8”1-1/2” 0” PRODUCT DESCRIPTION MATERIALS SIZE COLOR Double Stud Provides mechanical connection directly to Base Plate through Flashing. 3/8”-16 SS hardware and encapsulated gland washer included. Aluminum / SS 1-3/8” Hex x 1.5”Mill Flashing Sits on top of the Base Plate, and is captured by the Double Stud. 26 ga.Aluminum 15” L x 9-7/8” W x 1/2” H Black Mill1 Base Plate Base Plate is attached to the roof with lags. Flashing is attached to the Base Plate using the Double Stud. Galvanized Steel2 3-7/8” L x 3” W x 1/2” H Mill Lags (not included)(2) 3/8” lags (two point installation).Zinc 5/16” hex drive Zinc Mill(custom1)Black Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of marine-grade aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.11 Tech Brief Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 100 120 140 XR10 XR100 XR1000 160 10-20 100 120 140 160 30 100 160 40 100 160 50-70 160 80-90 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8’ spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. • 6’ spanning capability • Moderate load capability • Clear anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans 12 feet or more for commercial applications. • 12’ spanning capability • Extreme load capability • Clear anodized finish • Internal splices available