Loading...
HomeMy WebLinkAboutPLANS New SFD 1945 Gray Hawk Ct 2020-03-272015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 General Residential Electrical Requirements - Smoke detectors required inside and outside all bedrooms. - Min. one smoke detector required on each level. - Carbon monoxide detectors required within 15' of all bedrooms throughout home. - All outlets less than 5'6" AFF to be tamper resistant. - All circuits arc-fault except bathrooms and unfinished areas. - Min. (2) 20A, dedicated, GFCI/AFCI protected, small appliance, countertop circuits required in kitchens. - Min. (1) 20A, dedicated, GFCI protected outlet required within 36" of all lavs. - Garage circuits to be dedicated, 20A, and GFCI protected. - Laundry circuit to be 20A, GFCI protected. - All GFCI devices must be readily accessible. - Crawlspace lighting circuits to be GFCI protected. - Service receptacles required within 25' of all appliances. General Notes: -Min (1) emergency escape and rescue opening req’d per bedroom -Glazing to be tempered per R308 -Min (1) programmable thermostat req’d -Smoke alarm req’d in each sleeping room -Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior. -Fireblock/Draftsto p all chases and penetrations APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 03/27/2020 This structure must comply with the requirements of the 2017 National Electrical Code bas1s.com CD Review Es t e s P a r k , C o l o r a d o 8 0 5 1 7 16 9 2 B i g T h o m p s o n A v e n u e A3 Sheet No: 970.586.9140 Sheet Title:Sheet Title: Date: A R C H I T E C T U R E P. C. Architecture, P.C. Issue: © BASIS Rev. 1/15/2020 Es t e s P a r k , C o l o r a d o 8 0 5 1 7 TB D G r e y H a w k C t ELEVATIONS Ha b i t a t F o r H u m a n i t y 12 5 DECK Main Floor EL: 100' - 0" FIBER CEMENT SIDING 1X12 SKIRT BOARD RIDGE VENT, TYP.RIDGE VENT, TYP. CRAWL SPACE/ MECH RM. ACCESS DOOR 12 5 14 ' - 1 " BU I L D I N G H E I G H T GARAGE ENTRY Main Floor EL: 100' - 0"Garage Slab EL: 99'-5" LINE OF ORIGINAL GRADE, TYP FIBER CEMENT LAP SIDING 1X8 FASCIA, TYP CLASS 'A' ASPHALT SHINGLES, TYP TRUSS PORCH ENTRYINSTALL ICE & WATER SHIELD AT VALLEYS 1X6 CORNERBOARD, TYP CLAD WOOD WINDOWS W/ 1X4 CEDAR TRIM, TYP LINE OF FOUNDATION BEYOND, TYP 1X12 HARDBOARD TRIM RIDGE VENT, TYP. GUARDRAIL MIN. 36" HIGH <4" BETWEEN VERTICALS PORCH STEPS Garage Slab EL: 99'-5" RIDGE VENT, TYP. EXPOSED FOUNDATION WALL 12 5 ELEC. METER GAS METER Garage Slab EL: 99'-5" RIDGE VENT, TYP. 3 1/4" = 1'-0" West Elevation 1 1/4" = 1'-0" South Elevation 4 1/4" = 1'-0" North Elevation 2 1/4" = 1'-0" East Elevation    AArchitecturre, ,P.PP CC.CC 03/06/2020 General Notes All Elevations: -Asphalt shingles to meet 175 MPH wind-speed -All stone, stucco and siding to have barrier underneath at exterior walls -Roof slopes from 2:12 UP to 4:12 req double underlayment -Sills less than 24” w/72+” of fall req fall protection -Roof ventilation per R806 -All stairs, landings, guards, rails and walking surfaces to comply with R311 and R312 Reviewed by SAFEbuilt 03/27/2020 bas1s.com CD Review Es t e s P a r k , C o l o r a d o 8 0 5 1 7 16 9 2 B i g T h o m p s o n A v e n u e A4 Sheet No: 970.586.9140 Sheet Title:Sheet Title: Date: A R C H I T E C T U R E P. C. Architecture, P.C. Issue: © BASIS Rev. 1/15/2020 Es t e s P a r k , C o l o r a d o 8 0 5 1 7 TB D G r e y H a w k C t SECTION Ha b i t a t F o r H u m a n i t y 12 5 POST BEYOND 1/2" GYPSUM WALLBOARD FLOOR BEAM & JOISTS; RE: FLOOR FRAMING PLAN R-27 INSULATION @ RIM BOARD, TYP. PORCH BEAM BEYOND FIBER CEMENT SIDING ATTACHED OVER 1" RIGID INSULATION ON TYVEK HOUSEWRAP (no substitutions) ON 7/16" OSB WALL SHEATHING, TYP PAD FOOTING & POST; RE: FOUNDATION PLAN MECH. BEYONDmin 6mil POLYETHYLENE VAPOR BARRIER IN CRAWL SPACE TAPE + LAP SEAMS 1X4, 3 SIDES 1X12, 3 SIDES, NOTCH AROUND BEAM GUARDRAIL AIR BARRIER BEHIND TUB (THERMO-PLY OR EQ) BATHROOM KITCHEN CRAWL SPACE PROVIDE MECHANICAL VENTILATION FRONT PORCH T.O. Wall EL: 109' - 1 1/8" Main Floor EL: 100' - 0" 12" ENERGY HEEL, TYP 2X OVERFRAME 1X8 FASCIA MIN. R-45 BATT INSULATION @ BOTTOM CHORD OF TRUSS 1" RIGID FOAM OVER OSB PROV. 2" CLOSED CELL SPRAY FOAM IN CAVITY, FILL REMAINING W/ FIBERGLASS TYP. AT WALLS 5/8" GYP BOARD AT ROOF-CEILINGS ENGINEERED TRUSSES; RE: ROOF FRAMING PLAN LINE OF RIDGE IN FRONT R-19 BATT INSULATION w/ VINYL FACED VAPOR BARRIER VENTED HARDI-SOFFIT, TYP FIBER CEMENT ON EQ. SOFFIT BOARD MECHANICAL DISTRIBUTION TO SUPPLY CONDITIONED AIR TO CRAWL W/ RETURN DUCT TO ERV, RE: PLAN/ MANUAL J 12 5 DOOR TO HOUSE +/- 7" STEP 5/8" TYPE 'X' GYP AT HOUSE WALL SLOPE SLAB TO DOOR +/- 2% OVERHEAD DOOR ROLLED SLAB EDGE AT DOOR LINE OF EXISTING GRADE ENGINEERED TRUSSES 2x4 WALLS AT GARAGE HOUSE BEYOND T.O. Wall EL: 108' - 6" Main Floor/T.O. Wall EL: 100' - 0" STEP 2 SELF-ADHERED SILL FLASHING STEP 3 CORNER FLASHING PATCHES AT SILL STEP 4 INSTALL WINDOW PLUMB, LEVEL AND SQUARE SEALANT BEAD AT JAMBS AND HEAD (INSURE SEALANT IS CHEMICALLY COMPATIBLE WITH FOAM AND FLASHING) STEP 5 INSTALL SELF-ADHERED JAMB FLASHING STEP 6 INSTALL DRIP CAP (IF APPLICABLE, RE: DETAILS) INSTALL SELF-ADHERED HEAD FLASHING STEP 8 APPLY CORNER TAPE PATCHES AT HEAD. AIR SEAL WINDOW AROUND ENTIRE PERIMETER ON INTERIOR WITH SEALANT OR NON-EXPANDING FOAM STEP 1 HOUSEWRAP FOLDED IN AT JAMBS AND SILL STEP 7 FOLD DOWN HEAD HOUSEWRAP *HQHUDWHGE\5(6FKHFN:HE6RIWZDUH &RPSOLDQFH&HUWLILFDWH 3URMHFW +DELWDW+RXVH(VWHV3DUN (QHUJ\&RGH,(&& /RFDWLRQ(VWHV3DUN&RORUDGR &RQVWUXFWLRQ7\SH6LQJOHIDPLO\ 3URMHFW7\SH1HZ&RQVWUXFWLRQ &RQGLWLRQHG)ORRU$UHDIW *OD]LQJ$UHD  &OLPDWH=RQH +'' 3HUPLW'DWH &RQVWUXFWLRQ6LWH 7%'*UH\+DZN&W (VWHV3DUN&2 2ZQHU$JHQW 'HVLJQHU&RQWUDFWRU %$66$UFKLWHFWXUH %LJ7KRPSVRQ$YH (VWHV3DUN&2 3HUPLW1XPEHU Compliance: Passes using UA trade-off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ross Section 2 3/8" = 1'-0" Garage Section 5 NTS Window Flashing ROOF VENTING: Roof area is +/- 2,240 sf. Per IBC 1202.2.1 Ex2, ventilation req'd is 1/300 (7.5 sf/ 1,080 sq.in.) if min. 40% & max. 50% of ventilation is provided at ridge. 7.5/2 = 3.75 sf min. ventilation req'd at eave & ridge, each. Installing approx. 45' of ridge vent and 36' vented soffit provides req'd venting. (@ 6 sq.in. per lineal foot of ridge vent & 4.8 sq.in. per lineal foot of soffit vent). Provide 1" air gap at roofline blocking. Maintain 40%-50" of venting via ridge vent with chnages to lin. ft or vent sizes per calculations.    Arrchhiiiittttteeeeeeeeeeeeeeecccccccccccccctttttuuuurre, ,P.PP C.CC © BASIS 03/06/2020 Reviewed by SAFEbuilt 03/27/2020 Reviewed by SAFEbuilt 03/27/2020 Reviewed by SAFEbuilt 03/27/2020 S1.1 DATE REVSIONS: No. Description JOB # SHEET NO. DESIGN BY RA N C H S T Y L E - H A B I T A T H O M E 19 2 5 G R E Y H A W K C T ES T E S P A R K , L A R I M E R C O U N T Y , C O JRW18170 3/9/2020 PERMIT JRW + THB 03.09.2020 On Site Structural Secure ESeal#: JRW18170.20200309 Reviewed by SAFEbuilt 03/27/2020 S1.2 DATE REVSIONS: No. Description JOB # SHEET NO. DESIGN BY RA N C H S T Y L E - H A B I T A T H O M E 19 2 5 G R E Y H A W K C T ES T E S P A R K , L A R I M E R C O U N T Y , C O JRW18170 3/9/2020 PERMIT JRW + THB 03.09.2020 On Site Structural Secure ESeal#: JRW18170.20200309 Reviewed by SAFEbuilt 03/27/2020 S2.1 DATE REVSIONS: No. Description JOB # SHEET NO. DESIGN BY RA N C H S T Y L E - H A B I T A T H O M E 19 2 5 G R E Y H A W K C T ES T E S P A R K , L A R I M E R C O U N T Y , C O JRW18170 3/9/2020 PERMIT JRW + THB 03.09.2020 On Site Structural Secure ESeal#: JRW18170.20200309 Reviewed by SAFEbuilt 03/27/2020