Loading...
HomeMy WebLinkAboutPLANS 660 Community Dr Security 2016-10-17Responsibility Matrix Ge n e r a l C o n t r a c t o r (E C C ) El e c t r i c a l T r a d e B i d (E C C ) Se c u r i t y I n t e r g r a t o r (F F & E ) Te l / D a t a I n s t a l l e r ( E C C ) Ow n e r NA Ge n e r a l C o n t r a c t o r (E C C ) El e c t r i c a l T r a d e B i d (E C C ) Se c u r i t y I n t e r g r a t o r (F F & E ) Te l / D a t a I n s t a l l e r ( E C C ) Ow n e r NA Specification Division Responsibility Security Requirments SUPPLIED BY: INSTALLED BY: Hardwired Locks X X Division 08 Balance of Door hardware (hinges/operators, etc)X X Division 08 Security Low Voltage cable X X Division 28 Patch Cables (Fiber, Network)X X Division 28 Fiber Cable for Analog Cameras X X Division 28 Fiber Patch Panel X X Division 28 Security Data Cable (IP)X X Division 27 Security Data Outlets (IP)X X Division 27 Cameras and associated Video surveillance Devices X X Division 28 Access control card readers and associated Devices X X Division 28 Conduit and Back Boxes X X Division 16 Power & Power Receptacles X X Division 16 Network Video Recorders X X Division 28 Network Switches X X Owner Security Low Voltage Power Supplies X X Division 28 Door Contacts X X Division 08 AC- AC- DI DIU DR- IC- LA MC- MH RE- VI- ACP ACS DVR HE K MON NVR RIO SBP SR VE WS XLP XCP XDP AN AP GB- IR KP MD- PB- SI ST VBS X C-X CAM-XX-XXX X X X X X X X X X C-X C-X J J1 J2 J3 J4 J5 A - AMPERES AC - ABOVE COUNTER AFF - ABOVE FINISHED FLOOR AWG - AMERICAN WIRE GAUGE C - CONDUIT CAT - CATALOG CB - CIRCUIT BREAKER CCTV - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CL - CENTER LINE CLG - CEILING COND - CONDUCTOR CU - COPPER DVR - DIGITAL VIDEO RECORDER DWG - DRAWING EC - EMPTY CONDUIT EM - EMERGENCY EX - EXISTING FA - FIRE ALARM FACP - FIRE ALARM CONTROL PANEL G - GROUND HC - HUNG CEILING HZ - HERTZ IDF - INTERMEDIATE DISTRIBUTION FRAME JB - JUNCTION BOX LV - LOW VOLTAGE MAX - MAXIMUM MDF - MAIN DISTRIBUTION FRAME MER - MECHANICAL EQUIPMENT ROOM MIN - MINIMUM MTD - MOUNTED MTG - MOUNTING MTS - MANUAL TRANSFER SWITCH N - NEUTRAL NC - NORMALLY CLOSED NIC - NOT IN CONTRACT NO - NORMALLY OPEN No. - NUMBER NTS - NOT TO SCALE PA - PUBLIC ADDRESS PNL - PANEL POE - POWER OVER ETHERNET PTZ - PAN/TILT/ZOOM RM - ROOM STP - SHIELDED TWISTED PAIR XFRM - TRANSFORMER TEL - TELECOMMUNICATIONS TLR - TIME LAPSE RECORDER TS - TAMPER SWITCH TTB - TELECOMMUNICATIONS TERMINAL BOARD TTC - TELECOMMUNICATIONS TERMINAL CABINET TV - TELEVISION TYP - TYPICAL UON - UNLESS OTHERWISE NOTED UPS - UNINTERRUPTIBLE POWER SUPPLY UTP - UNSHIELDED TWISTED PAIR V - VOLTS VA - VOLT-AMPERES VM - VOLTMETER VP - VAPOR PROOF W - WATTS WP - WATERPROOF WT - WATERTIGHT 1. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING PURPOSES. THE SECURITY DRAWINGS SHOULD ONLY BE USED FOR SECURITY SYSTEMS INSTALLATION AND COORDINATION. 2. ALL MOUNTING SPECIFICS SHALL BE AS INDICATED IN THE LEGEND UNLESS OTHERWISE NOTED IN THE SECURITY DRAWINGS. MOUNTING CONDITIONS IDENTIFIED ON THE SECURITY DRAWINGS SHALL TAKE PRECEDENCE OVER THE LEGEND DESACIPTIONS. 3. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES PRIOR TO INSTALLATION. 4. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED. 5. THE SECURITY CONTRACTOR SHALL RESTORE CEILINGS AND WALLS AND ANY OTHER SURFACES AFFECTED BY HIS WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION UPON COMPLETION OF HIS WORK. 6. FIRE STOPPING OF ALL PENETRATIONS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR AS REQUIRED BY CODE. 7. ALL DEVICES, WIRING, TERMINATIONS, AND OTHER REQUIRED ROUGH-IN NOT DESIGNATED "BY OTHERS" ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR. 8. COORDINATE ALL EXTERIOR CAMERA LOCATIONS WITH THE LANDSCAPE TO ENSURE THAT CAMERA VIEW ARE NOT OBSTRUCTED. 1. ALL CONDUIT AND BACKBOXES SHALL CONFORM TO BUILDING STANDARD ELECTRICAL SPECIFICATIONS. ALL CABLES SHALL BE PLENUM RATED WHERE REQUIRED. 2. ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED. 3. ALL CONDUIT USED IN POTENTIALLY DAMP OR WET LOCATIONS, EXPOSED OUTDOORS, OR IN HAZARDOUS AREAS SHALL BE INTERMEDIATE STEEL CONDUIT (IMC). ALL EXTERIOR CONDUIT IN SLAB SHALL BE PVC. ALL CONDUIT OTHER THAN SPECIFIED TO BE IMC OR PVC SHALL BE ELECTRICAL METALLIC TUBING (EMT). 4. ALL CONDUIT SHALL BE ROUTED ABOVE CEILINGS, BELOW FLOORS, OR WITHIN WALLS. NO CONDUIT SHALL BE EXPOSED UNLESS APPROVED BY THE ARCHITECT. 5. PROVIDE PULL STRINGS IN ALL CONDUIT AND PULLBOXES AS REQUIRED. ALL CONDUITS SHALL HAVE PLASTIC BUSHINGS INSTALLED AT OPEN ENDS PRIOR TO PULLING WIRE. 6. ALL BACKBOXES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED. 7. ALL BACKBOXES MOUNTED WITHIN FIRE RATED PARTITIONS SHALL MEET THE FIRE RATING OF THE PARTITION AS REQUIRED BY CODE. 8. COORDINATE THE EXACT LOCATION OF ALL PULL AND BACKBOXES WITH ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. 9. ALL JUNCTION AND PULLBOXES SHALL BE PROVIDED WITH ACCOMPANYING BLANK COVER PLATE. 10. JUNCTION BOXES LOCATED ABOVE DOORS WITH NO ACCESSIBLE CEILING SHALL BE SECURED WITH TAMPER PROOF SCREWS. 11. PROVIDE WATERTIGHT SEALING ASSEMBLIES WITH PRESSURE BUSHING AS REQUIRED FOR EXTERIOR PENETRATIONS. 12. JUNCTION AND PULLBOXES IN EXTERIOR LOCATIONS SHALL BE WATERPROOF. 13. ALL CABLE RUNS IN CEILING AREAS WHERE CONDUIT OR CABLE TRAY IS NOT SPECIFIED SHALL BE SUPPORTED WITH SIMILAR SUPPORT OR WITH THE USE OF J-HOOKS AT 5' INTERVALS ABOVE CEILING TILES. 14. COORDINATE WITH ELECTRICAL CONTRACTOR FOR SECURITY DEVICE AND CONTROL PANEL POWER REQUIREMENTS. 15. WIRE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION. ALL TERMINATIONS SHALL MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 0.5" OR LESS OF FINAL TERMINATION. ALL WIRES SHALL BE LABELED WITHIN 6.5" OF FINAL TERMINATION. ALL LABELS SHALL BE MACHINE PRINTED OR STENCILED. NO HAND LETTERED LABELS SHALL BE USED. 16. ANY CONDUIT ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO REPRESENT INSTALLED PATHS OR DISTANCES. ACTUAL ROUTING AND BOX LOCATIONS SHALL BE FIELD VERIFIED AND COORDINATED WITH OTHER DISCIPLINES BY THE INSTALLING CONTRACTOR. 1. ALL DEVICES, WIRING, TERMINATION AND OTHER REQUIRED ROUGH-IN NOT DESIGNATED "AS BY OTHERS", ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR. 2. ALL SECURITY DEVICES PROVIDED BY THE SECURITY CONTRACTOR. NOTES BELOW INDICATE WORK BY THE ELECTRICAL CONTRACTOR. 3. PROVIDE 4" X 4" X 2-1/4" DEEP BOX WITH SINGLE GANG DEVICE RING JB FLUSH MOUNTED 48" A.F.F WITH 3 /4" CONDUIT STUBUP TO J1 BY ELECTRICAL CONTRACTOR. 4. STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE DOOR BACK BOX EL TO JUNCTION BOX J1 LOCATED ABOVE ACCESSIBLE CEILING, BY ELECTRICAL CONTRACTOR. 5. STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE STRIKE SIDE OF THE DOOR ES TO JUNCTION BOX J1 LOCATED ABOVE ACCESSIBLE CEILING, BY ELECTRICAL CONTRACTOR. DEVICE DETAIL NUMBER DETAIL NUMBER DEVICE TYPE CAM = CCTV CAMERA DEVICE TYPELEVEL DEVICE RISER POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS RISER POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. SECURITY CONTROL/EQUIPMENT ROOM POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TO SECURITY WITHIN A 4" X 4" BOX SURFACE MOUNTED BEHIND THE CONSOLE/RACK AT 18" AFF WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MAGNOTOMETER/X-RAY SCANNER POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET CONNECTED TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE FLUSH MOUNTED IN THE FLOOR. EXTERIOR CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE 5A AT 120VAC. FOR EXTERIOR LOCATION PROVIDE POWER IN 4"X4"OUTDOOR RATED BOX POLE MOUNTED CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON- EMERGENCY CIRCUIT DEDICATED TO SECURITY PROVIDED WITHIN A NEMA 4X ENCLOSURE MOUNTED AT THE BASE OF THE POLE WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 15 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE 1A AT 120VAC. ELECTRIC EXIT DEVICE POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ADJACENT TO THE DOOR OR AS SHOWN ON DRAWINGS WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC. X-RAY/METAL DETECTOR POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE FLUSH MOUNTED IN FLOOR. ELEVATOR SECURITY EQUIPMENT POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTIONS TO A 120VAC 20A NON- EMERGENCY CIRCUIT DEDICATED TO SECURITY IN THE ELEVATOR MACHINE ROOM(S) AS INDICATED ON THE DRAWINGS. TYPICAL LOAD FOR EACH CIRCUIT SHALL BE 10A. PROVIDE CONNECTION IN A SURFACE MOUNTED BOX MOUNTED AT 8' A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS UPS POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 240VAC 65A EMERGENCY CIRCUIT DEDICATED TO SECURITY AS INDICATED ON THE DRAWINGS. THE CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX SURFACE MOUNTED IN THE BACK OF THE SECURITY EQUIPMENT RACK, 18" A.F.F. AND SHALL HAVE WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. VEHICLE GATE POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A DEDICATED 120V AC HARD WIRED 20AMP CIRCUIT WITHIN THE GATE HOUSING. THE JUNCTION BOX SHALL BE OUTDOOR RATED. THE ELECTRICAL CONTRACTOR SHALL PROVIDE SURGE PROTECTION FOR THE CIRCUIT EACH GATE SHOULD HAVE A DEDICATED CIRCUIT MULTIPLE GATES SHOULD NEVER SHARE CIRCUIT. SITE POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE WALL MOUNTED 12" AAF. ELECTRIC EXIT DEVICE POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A UN- SWITCHED CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ADJACENT TO THE DOOR OR AS SHOWN ON DRAWINGS WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC. SECURITY EMERGENCY CALL STATION POWER (EMERGENCY CIRCUIT) HARD WIRE TO 120VAC 20A CIRCUIT EMERGENCY CIRCUIT DEDICATED FOR EMERGENCY CALL STATIONS. MOUNTING HT OF CALL BOX TO BE 36" AFF TO BOTTOM OF UNIT. POWER TO BE BROUGHT DOWN IN COLUMN TO 4" X 4" BOX TO ALIGN WITH 3/4" KO ON BACK OF UNIT. 5 UNITS CAN BE POWERED FROM SAME CIRCUIT. ELEVATOR CAMERA POWER (NON-EMERGENCY CIRCUIT) ELEVATOR CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON- EMERGENCY CIRCUIT DEDICATED FOR THE SECURITY CAMERA. THE OUTLET SHALL BE MOUNTED ABOVE THE CAB AND PROVIDE ADEQUATE SPACE FOR A PLUG IN TYPE TRANSFORMER. INTERIOR PTZ CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH CAMERA POWER SUPPLY ACTUAL LOAD SHALL NOT EXCEED 3A AT 120VAC. ACCESS CONTROL READER ACCESS CONTROL PANEL ACCESS CONTROL SERVER ANNUNCIATOR ALARM PANEL DOOR INTERLOCK DOOR INTERFACE UNIT DOOR RELEASE DIGITAL VIDEO RECORDER GLASS BREAK SENSOR HEAD END MONITORING LOCATION INTERCOM INFRARED BEAM ALARM KEYPAD FIRE RELAY (FOR LOCK RELEASE) LOCAL ALARM MAGNETIC CONTACT MOTION DETECTOR MAGNETIC HOLD OPEN VIDEO SURVEILLANCE NETWORK VIDEO RECORDER PUSH BUTTON REQUEST TO EXIT RELAY IN/OUT SECURITY BADGE PRINTER SECURITY RISER LOCATION SIREN/SOUNDER STROBE VIDEO INTERCOM VIDEO ENCODER VIBRATION SENSOR WORKSTATION LOCK POWER SUPPLY CAMERA POWER SUPPLY DEVICE POWER SUPPLY CCTV CAMERA - FIXED CCTV CAMERA - PTZ CCTV CAMERA - CEILING MOUNT CCTV CAMERA - WALL MOUNT CCTV CAMERA - CORNER MOUNT CCTV CAMERA - CORNER MOUNT PROVIDE 4" X 4" X 2-1/4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. PROVIDE 6" X 6" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. PROVIDE 10" X 10" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. PROVIDE 12" X 12" X 6" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. PROVIDE 16" X 16" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. PROVIDE 20" X 20" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 XX-XXX DEVICE TYPE AC-X DETAIL NUMBER LEVEL DEVICE NUMBER DRAWING LIST: ABBREVIATIONS: SECURITY ELECTRICAL NOTES: SYMBOLS:GENERAL NOTES: SECURITY CONDUIT AND WIRING NOTES: EQUIPMENT SYMBOL & TAG DEFINITIONS: SECURITY DEVICE NOTES: SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 1 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY COVER SHEET TY-000 NUMBER NAME TY-000 SECURITY COVER SHEET TY-102 SECURITY OVERALL PLAN - LOWER LEVEL TY-103 SECURITY PART PLAN - UPPER LEVEL NORTH TY-104 SECURITY PART PLAN - UPPER LEVEL SOUTH TY-300 SECURITY RISER DIAGRAM TY-400 SECURITY DEVICE DETAILS DN A B C DN C - 3 C - 1 7 C - 1 C - 3 3 4 5 6 7 A1 A B C D E F A2 A3 A4 AB AA A5 AC AD AE AF AG AH H G L MP GROUP EX 124 STAIR 120 ? ? ELEV 117 EMP ENTRY 103 COMMUNITY KITCHEN 142 KITCHEN 112 VEST 101LOUNGE 102 WOMEN 104 COMMUNITY 141 EXIT STAIR S10 GYM 131 GYM STORAGE 132 P&R DIRECTOR 108 STORAGE 143 ? ? CLASSROOM 114 RECV & STOR 115 STOR 113 WOMEN 111 STRENGTH 123 MEN 105 GAMES 106 STAFF 107 ELEC 109 ? ? JR GOLF 121 HITTING 122 ? 132A 132B MC - 2 AC - 71 AC - 71 MC - 1 MC - 1 MD - 4 MC - 1 AC - 72KP-1 MC - 2 MD - 4 KP-1 KP-1 MD - 4 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 2 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY OVERALL PLAN - LOWER LEVEL TY-102 1/8" = 1'-0"1 SECURITY OVERALL PLAN - LOWER LEVEL PARENT A B CC - 1 3 4 5 6 7 A1 A B C D E F A2 A3 A4 AB AA A5 AC AD AE AF AG AH H G M/P GROUP EX 262 ST. 263 EXIT STAIR S10 CARDIO 261 ? ? MEN 203 WOMEN 204 ADMIN 271 DESK STAFF 272 EXEC DIR 281 ASST 279 WATER & FIRE ENTRY 273 ? ? IT 274 HR 283 FACILITY DIR 285 FINANCE 287 TEMP 284 COPY 278 LAN 276 MARKET 277 CONFERENCE 275 ELEC 282 ? ? MC - 1 TT-200 1 TYP W - 1 NVR HE PROVIDE ENCODER FOR DIGITAL SIGNAGE THROUGH VMS, MON BY DIV-27 WS AC - 1 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 4 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY PART PLAN - UPPER LEVEL NORTH TY-103 1/8" = 1'-0"1 SECURITY PART PLAN - UPPER LEVEL NORTH A B CC - 1 C - 1 C - 1 C - 4 C - 4 C - 1 7 3 4 5 6 7 AH 6.9 8 95.4 M L M.6 N P Q EH NJ E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EG EF EE ED EC EB EA 1 2 ? ? POOL MECH 253 POOL OFFICE 256 W. LOCKERS 221 FAM CHANGING 212 PARTY 211 INDOOR PLAY 205M. LOCKERS 231 W. TOILETS 223 JAN 229 ACR1 213 ACR2 214 CHG 215 ACR3 216 VESTIBULE 201 LOBBY 202 ? ? POOL STORAGE 255 CIRC 259 OFFICE 206 KIDS T 207 KID WATCH 288 ELEC 254 GUARDS 258 ? ? ? ? ? ? M. TEAM LOCKER A107 W. TEAM LOCKERS A106 POOL STORAGE A108 EXIST NATATORIUM A110 EXIST POOL MECH A112 EXIST POOL EQUIP A114 EXIST LAUNDRY A111 EXIST ELEC A113 FOYER A101 MECHANICAL A102 ? ? M. SHOWERS 232 M. TOILETS 233 W. LOCKERS 221 EXIST POOL DECK A109 A115A A114A A115B A114B A112 A113 XA110 ? ? 253B 255 ? 256 254B ? MD - 1 MC - 1 MC - 1 MC - 1 MC - 2 AC - 72 MC - 1 MD - 4 KP-1 PROVIDE ENCODER FOR DIGITAL SIGNAGE THROUGH VMS, MON BY DIV-27 MC - 2 WS MC - 1 MC - 2 KP-1 AC - 72MON SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 6 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY PART PLAN - UPPER LEVEL SOUTH TY-104 1/8" = 1'-0"1 SECURITY PART PLAN - UPPER LEVEL SOUTH LAN 276 AC-X AC-X DOOR DOOR ACCESS CONTROL PANEL MC-X DOOR MC-X DOOR MC-X DOOR MC-X DOOR AC-X AC-X DOOR DOOR MC-X DOOR MC-X DOOR MC-X DOOR MC-X DOOR MD-X ROOM MC-X DOOR MD-X ROOM MC-X DOOR LAN 276 INTRUSION DETECTION PANEL LAN 276 NETWORK SWITCH (FBO) KP-X ROOM KP-X ROOM SECURITY CCTV TYPICAL DEVICE RISER DIAGRAM1SCALE: NTS LEVEL 1 H H ACCESS CONTROL TYPICAL DEVICE RISER DIAGRAM3SCALE: NTS LEVEL 2 Y Y A AA A Y Y A AA A LEVEL 1 LEVEL 2 H H INTRUSION DETECTION TYPICAL DEVICE RISER DIAGRAM2SCALE: NTS LEVEL 2 LEVEL 1 B A B A LAN (FBO) INTERFACE TO IDS INTERFACE TO ACS Y-1 Y-1 C-X CAM-01-## C-X CAM-01-## C-X CAM-01-## C-X CAM-01-## WCW#991380-S-PL4-Conductor #16 AWG/STRD/NO SHIELD -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL -PL Y4- Y3- Y2- Y1- WCW#442360-S 2-COND/ 12AWG/STRD 8 COND/ 18AWG/STRD/SHLD w/ DRAIN WCW COMPOSITE CABLE *SPECIFY RISER OR PLENUM 2 COND/ 18 AWG/STRD/TWST/SHLD w/ DRAIN 3 PR/ 18AWG/STRD/TWST/SHLD w/DRAIN Y- N - O - P - Q - 8-Conductor #18 AWG/STRD/SHLD/w/DRAIN 6-Conductor #18 AWG/STRD/NO SHIELD 4-Conductor #22 AWG/STRD/NO SHIELD WCW#762380-S WCW#4150102-S WCW#160100-S WCW#555619-S WCW#659211-S WCW#441367-S WCW#043106AL-S WCW#444351-03S WCW#042003-S WCW#442380-S WCW#444366-S WCW#4160201 WCW#714510-VNQ WCW#002352-S-PL WCW#444381-S-PL WCW#U002391-11S-PL WCW#160100-PL WCW#414104-S CABLE DESCRIPTION PART NUMBER 4 COND/ 18AWG PARALLEL MID-CAP M - L - CABLE TYPES K - I - H - G - F - E - D - C - B - A - J - 2-COND/ 22AWG/STRD/TWST 2 PR/ 22AWG/STRD/TWST/SHLD w/ DRAIN 4 COND/ 18 AWG/STRD/TWST/SHLD w/ DRAIN 2 PAIR EA. PR Shielded 18AWG. CATEGORY 6 LAN CABLE RG-59U COAX 2 COND/ 16 AWG/STRD/TWST 1 PR/ 22 AWG/STRD/TWST/SHLD w/ DRAIN WCW COMPOSITE CABLE PN# CBORD-A-AC-PL-EXT 6 COND/ 22 AWG/STRD/TWST/SHLD w/ DRAIN 2 PR/ 24 AWG/STRD/TWST/SHLD w/ DRAIN 4 COND/ 18 AWG/STRD/TWST 2 COND/ 18 AWG/STRD/TWST SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 3/16" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 6 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY RISER DIAGRAM TY-300 FINISHED FLOOR FINISHED CEILING SECURE SIDE ACCESS CONTROL - SINGLE DOOR - CARD READER, ELECTRIFIED MORTISE LOCK, DOOR POSITION SWITCH 6" CEILING SLAB 7 1 2 3 - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING - DOOR CONTACT (RECESSED) - ELECTRIFIED MORTISE LOCK, FREE EGRESS (INTERGRATED REQUEST TO EXIT) 4 - WIRE TRANSFER HINGE 5 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX 6 - STUB 3/4" CONDUIT WITH DRAG LINE. J1 3'-2" -- DOOR CLOSER AS PART OF DOOR HARDWARE (TYPE NOT SPECIFIED) 8 - 3/4" CONDUIT WITH DRAG LINE TO NEAREST ACCESSIBLE CEILING TO CABLE TRAY TYPICAL PLAN VIEW - ACCESS CONTROL (TYPE?????) PROVIDE SINGLE GANG BACK BOX, MOUNTED 3'-2" AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS AC-1 134 2 5 7 8 6 6 12 4 3 C-1 DETAIL NOTES: 1. FIXED POE DOME CAMERA 2. TELECOM OUTLET 8 PIN JACK INSIDE PLENUM RATED GEM BOX 3. CAMERA PATCH CORD 4. HORIZONTAL 4-PAIR UTP CABLE WITH 20' SLACK 5. J-HOOK 6. 1" DIAMETER HOLE # VIDEO SURVEILLANCE - FIXED IP DOME - FLUSH OR SURFACE - INTERIOR FINISHED CEILING DETAIL NOTES: 1. FIXED POE DOME CAMERA 2. TELECOM OUTLET 8 PIN JACK 3. HORIZONTAL 4-PAIR UTP CABLE 4. 3/4" EMT CONDUIT 5. BACK BOX (J#), BACK BOX TO BE SECURED TO STRUCTURE. # INACCESSIBLE CEILING MOUNTED - INTERIOR DETAIL NOTES: 1. REFER TO SPECIFICATION 28 23 29 FOR CAMERA MODEL REQUIREMENTS. 2. REFER TO CONTRACTOR RESPONSIBILITY LEGEND ON TY-000. 3. REFER TO XXXXX FOR CAMERA VIEW TYPE (RECOGNITION/IDENTIFICATION/DETECTION) INSTALLATION DESCRIPTION CAMERA IS INSTALLED ONTO THE BACK BOX VIA CONVERTER PLATE. THE GANG BOX ITSELF IS EITHER ON THE SURFACE OF THE HARD CEILING OR INSIDE THE CEILING. ACCESSIBLE CEILING MOUNTED - INTERIOR FINISHED CEILING CEILING SLAB CEILING SLAB 3 2 5 4 6 1 2 3 5 1 4 # C-17 DETAIL NOTES: 1. PENETRATION IN WALL FILLED WITH APPROVED SEALANT 2. CCTV fIXED CAMERA IN ENVIRONMENTAL HOUSING MOUNTED 16' MINIMUM (INTERIORS), 20' MINIMUM (EXTERIOR) 4. EXTERIOR WALL 5. 6"x6"x4" DEEP BOX BY (BY ELECTRICAL CONTRACTOR). 6. IP JUMPER CABLE BY SECURITY CONTRACTOR. 7. 3/4" CONDUIT TO NEAREST ACCESSIBLE CEILING OR CABLE TRAY (BY ELECTRICAL CONTRACTOR). 3. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR). 6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR). VIDEO SURVEILLANCE - FIXED IP DOME - WALL PENDANT MOUNTED - EXTERIOR 7 3 6 5 4 2 1 AC-71 FINISHED CEILING CEILING SLAB FINISHED FLOOR TO 120VAC PROTECTED SIDE TYPICAL PLAN VIEW FA 6"TYP. 3'-2" J1 1 4 1 9 2 3 - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING. - DOOR CONTACT (RECESSED) 4 - WIRE TRANSFER HINGE (EPT 10) 7 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX 8 - STUB 3/4" CONDUIT WITH DRAG LINE. 5 - REQUEST TO EXIT, PUSH BUTTON 6 - BREAK GLASS UNIT 1 -- DOOR CLOSER AS PART OF IRONMONGERY (TYPE NOT SPECIFIED) - CARD READER (PROXIMITY/SWIPE) PROVIDE SINGLE GANG BACK BOX, MOUNTED 3'-2" AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS - FIRE EXIT HARDWARE (W/REQUEST TO EXIT) 3 4 3 ACCESS CONTROL - SINGLE DOOR - CARD READER, ELECTRIFIED EXIT DEVICE, DOOR POSITION SWITCH 8 2 LPS AC-72 FINISHED CEILING CEILING SLAB FINISHED FLOOR TO 120VAC PROTECTED SIDE TYPICAL PLAN VIEW FA 6"TYP. 3'-2" J1 1 2 4 1 9 2 3 - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING. - DOOR CONTACT (RECESSED) 4 - WIRE TRANSFER HINGE (EPT 10) 7 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX 8 - STUB 3/4" CONDUIT WITH DRAG LINE. 5 - REQUEST TO EXIT, PUSH BUTTON 6 - BREAK GLASS UNIT 1 -- DOOR CLOSER AS PART OF IRONMONGERY (TYPE NOT SPECIFIED) - CARD READER (PROXIMITY/SWIPE) PROVIDE SINGLE GANG BACK BOX, MOUNTED 3'-2" AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS - FIRE EXIT HARDWARE (W/REQUEST TO EXIT) 33 4 4 4 3 3 ACCESS CONTROL - DOUBLE DOOR - CARD READER, ELECTRIFIED EXIT DEVICE, DOOR POSITION SWITCH 8 LPS # C-3 DETAIL NOTES: 1. CAMERA BACK BOX (PROVIDED BY SECURITY CONTRACTOR) 2. TOGGLE BOLTS (AS REQUIRED) 3. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR). 6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR). 4. CEILING SOFFIT 5. CAMERA 6. IP JUMPER CABLE (BY SECURITY CONTRACTOR). 7. 3/4" CONDUIT TO NEAREST ACCESSIBLE CEILING OR CABLE TRAY (BY ELECTRICAL CONTRACTOR). VIDEO SURVEILLANCE - FIXED IP DOME - WALL FLUSH MOUNTED - INTERIOR 5 7 3 4 2 1 6 # C-4 DETAIL NOTES: 1. CAMERA BACK BOX (PROVIDED BY SECURITY CONTRACTOR) 2. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR). 6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR). 3. CEILING 4. CAMERA 5. IP JUMPER CABLE (BY SECURITY CONTRACTOR). 6. 3/4" CONDUIT TO NEAREST ACESSIBLE CEIILING OR CABLE TRAY (BY ELECTRICAL CONTRACTOR). VIDEO SURVEILLANCE - FIXED IP DOME - WALL SURFACE MOUNTED - INTERIOR 4 1 5 6 3 7 FINISHED FLOOR FINISHED CEILING MAGNETIC CONTACT - SINGLE DOOR - FLUSH MOUNTED 6" CEILING SLAB 3 1 - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING. 3 - DOOR CONTACT (RECESSED) 1 2 2 - STUB 3/4" CONDUIT WITH DRAG LINE. 2 J1 4 - STUB 3/4" CONDUIT WITH DRAG LINE TO NEAREST CABLE TRAY OR ACCESSIBLE CEILING. 4 TYPICAL PLAN VIEW SECURE SIDE MC-1 6"TYP. MAGNETIC CONTACT - DOUBLE DOOR - FLUSH MOUNTED J1 4 3 2 2 SECURE SIDE FINISHED FLOOR FINISHED CEILING CEILING SLAB 2 11 3 1 - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING. - DOOR CONTACT (RECESSED) 2 - STUB 3/4" CONDUIT WITH DRAG LINE. 4 - STUB 3/4" CONDUIT WITH DRAG LINE TO NEAREST CABLE TRAY OR ACCESSIBLE CEILING. TYPICAL PLAN VIEW MC-2 KP-1 3 3 4 4 1 2 1 2 4'-6" - PANIC BUTTON (PUSH BUTTON TYPE) DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING. - PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4" - STUB 3/4" CONDUIT WITH DRAG LINE. NOTE: REVIEW KEYPAD LOCATION WITH CONSULTANT AND ARCHITECT PRIOR TO INSTALLATION. - 3/4" CONDUIT WITH DRAG LINE TO NEAREST ACCESSIBLE CEILING TO CABLE TRAY. FINISHED CEILING KEYPAD - WALL MOUNTED - FLUSH FINISHED FLOOR CEILING SLABJ1 MD-1 STRUCTURAL SUPPORT TO BUILDING PER NEC NOTE: REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR EXACT DEVICE LOCATIONS. CONDUIT AND CABLE PER DWGS AND SPECS. TO CABLE TRAY. INFARARED MOTION DETECTOR PER SPECS. GWB OR CEILING PER ROOM FINISH SCHEDULE. MOTION DETECTOR - CEILING MOUNTED - FLUSH STANDARD OCTAGONAL OR 4" SQUARE J-BOX TO MATCH WITH DETECTOR. NOTE: REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR EXACT DEVICE LOCATIONS. WALL PER ROOM FINISH SCHEDULE. MOTION DETECTOR - WALL MOUNTED - SURFACE STANDARD OCTAGONAL OR 4" SQUARE J-BOX TO MATCH WITH DETECTOR. MD-4 CONDUIT AND CABLE PER DWGS AND SPECS. INFARARED MOTION DETECTOR PER SPECS. TO CABLE TRAY. (4') ACCESS CONTROL POWER SUPPLY ACCESS CONTROL PANEL LOCK POWER SUPPLY FLOOR SLAB FLOOR SLAB (8') DUPLEX OUTLET WITH 120VAC 20AMP DEDICATED CIRCUITS ON EMERGENCY POWER. FIRE TREATED PLYWOOD BACKBOARD, SIZED AS NOTED. WIRE TROUGH (TYPICAL FOR 2) POWER STRIP (6 OUTLETS MIN). DETAIL NOTES: CLASS E FIRE RELAY TYPICAL SECURITY WALL FIELD ELEVATION 3 1 2 1 4 2 4 3 1 W-1 ACCESS CONTROL PANEL (AS REQUIRED) INTRUSION DETECTION ALARM PANEL SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 3/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 2 : 1 8 : 0 8 P M C: \ S M W \ R e v i t \ S M W _ 1 6 1 1 6 _ T _ E V C C _ R 1 6 _ s m o e d e . r v t 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ES T E S V A L L E Y C O M M U N I T Y C E N T E R SO NF 10-17-2016 16003 SECURITY DEVICE DETAILS TY-400