HomeMy WebLinkAboutPLANS 660 Community Dr Security 2016-10-17Responsibility Matrix
Ge
n
e
r
a
l
C
o
n
t
r
a
c
t
o
r
(E
C
C
)
El
e
c
t
r
i
c
a
l
T
r
a
d
e
B
i
d
(E
C
C
)
Se
c
u
r
i
t
y
I
n
t
e
r
g
r
a
t
o
r
(F
F
&
E
)
Te
l
/
D
a
t
a
I
n
s
t
a
l
l
e
r
(
E
C
C
)
Ow
n
e
r
NA Ge
n
e
r
a
l
C
o
n
t
r
a
c
t
o
r
(E
C
C
)
El
e
c
t
r
i
c
a
l
T
r
a
d
e
B
i
d
(E
C
C
)
Se
c
u
r
i
t
y
I
n
t
e
r
g
r
a
t
o
r
(F
F
&
E
)
Te
l
/
D
a
t
a
I
n
s
t
a
l
l
e
r
(
E
C
C
)
Ow
n
e
r
NA
Specification
Division
Responsibility
Security Requirments SUPPLIED BY: INSTALLED BY:
Hardwired Locks X X
Division 08
Balance of Door hardware
(hinges/operators, etc)X X
Division 08
Security Low Voltage cable X X
Division 28
Patch Cables (Fiber, Network)X X
Division 28
Fiber Cable for Analog Cameras X X
Division 28
Fiber Patch Panel X X
Division 28
Security Data Cable (IP)X X
Division 27
Security Data Outlets (IP)X X
Division 27
Cameras and associated Video
surveillance Devices X X
Division 28
Access control card readers and
associated Devices X X
Division 28
Conduit and Back Boxes X X
Division 16
Power & Power Receptacles X X
Division 16
Network Video Recorders X X
Division 28
Network Switches X X
Owner
Security Low Voltage Power
Supplies X X
Division 28
Door Contacts X X
Division 08
AC-
AC-
DI
DIU
DR-
IC-
LA
MC-
MH
RE-
VI-
ACP
ACS
DVR
HE
K
MON
NVR
RIO
SBP
SR
VE
WS
XLP
XCP
XDP
AN
AP
GB-
IR
KP
MD-
PB-
SI
ST
VBS
X
C-X
CAM-XX-XXX
X
X
X
X
X
X
X
X
X
C-X
C-X
J
J1
J2
J3
J4
J5
A - AMPERES
AC - ABOVE COUNTER
AFF - ABOVE FINISHED FLOOR
AWG - AMERICAN WIRE GAUGE
C - CONDUIT
CAT - CATALOG
CB - CIRCUIT BREAKER
CCTV - CLOSED CIRCUIT TELEVISION
CKT - CIRCUIT
CL - CENTER LINE
CLG - CEILING
COND - CONDUCTOR
CU - COPPER
DVR - DIGITAL VIDEO RECORDER
DWG - DRAWING
EC - EMPTY CONDUIT
EM - EMERGENCY
EX - EXISTING
FA - FIRE ALARM
FACP - FIRE ALARM CONTROL PANEL
G - GROUND
HC - HUNG CEILING
HZ - HERTZ
IDF - INTERMEDIATE DISTRIBUTION FRAME
JB - JUNCTION BOX
LV - LOW VOLTAGE
MAX - MAXIMUM
MDF - MAIN DISTRIBUTION FRAME
MER - MECHANICAL EQUIPMENT ROOM
MIN - MINIMUM
MTD - MOUNTED
MTG - MOUNTING
MTS - MANUAL TRANSFER SWITCH
N - NEUTRAL
NC - NORMALLY CLOSED
NIC - NOT IN CONTRACT
NO - NORMALLY OPEN
No. - NUMBER
NTS - NOT TO SCALE
PA - PUBLIC ADDRESS
PNL - PANEL
POE - POWER OVER ETHERNET
PTZ - PAN/TILT/ZOOM
RM - ROOM
STP - SHIELDED TWISTED PAIR
XFRM - TRANSFORMER
TEL - TELECOMMUNICATIONS
TLR - TIME LAPSE RECORDER
TS - TAMPER SWITCH
TTB - TELECOMMUNICATIONS TERMINAL BOARD
TTC - TELECOMMUNICATIONS TERMINAL CABINET
TV - TELEVISION
TYP - TYPICAL
UON - UNLESS OTHERWISE NOTED
UPS - UNINTERRUPTIBLE POWER SUPPLY
UTP - UNSHIELDED TWISTED PAIR
V - VOLTS
VA - VOLT-AMPERES
VM - VOLTMETER
VP - VAPOR PROOF
W - WATTS
WP - WATERPROOF
WT - WATERTIGHT
1. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING
PURPOSES. THE SECURITY DRAWINGS SHOULD ONLY BE USED FOR SECURITY
SYSTEMS INSTALLATION AND COORDINATION.
2. ALL MOUNTING SPECIFICS SHALL BE AS INDICATED IN THE LEGEND UNLESS
OTHERWISE NOTED IN THE SECURITY DRAWINGS. MOUNTING CONDITIONS
IDENTIFIED ON THE SECURITY DRAWINGS SHALL TAKE PRECEDENCE OVER THE
LEGEND DESACIPTIONS.
3. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES
PRIOR TO INSTALLATION.
4. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS
OTHERWISE NOTED.
5. THE SECURITY CONTRACTOR SHALL RESTORE CEILINGS AND WALLS AND ANY
OTHER SURFACES AFFECTED BY HIS WORK WITH LIKE MATERIALS TO MATCH
EXISTING CONSTRUCTION UPON COMPLETION OF HIS WORK.
6. FIRE STOPPING OF ALL PENETRATIONS SHALL BE PROVIDED BY THE SECURITY
CONTRACTOR AS REQUIRED BY CODE.
7. ALL DEVICES, WIRING, TERMINATIONS, AND OTHER REQUIRED ROUGH-IN NOT
DESIGNATED "BY OTHERS" ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR.
8. COORDINATE ALL EXTERIOR CAMERA LOCATIONS WITH THE LANDSCAPE TO
ENSURE THAT CAMERA VIEW ARE NOT OBSTRUCTED.
1. ALL CONDUIT AND BACKBOXES SHALL CONFORM TO BUILDING STANDARD
ELECTRICAL SPECIFICATIONS. ALL CABLES SHALL BE PLENUM RATED WHERE
REQUIRED.
2. ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.
3. ALL CONDUIT USED IN POTENTIALLY DAMP OR WET LOCATIONS, EXPOSED
OUTDOORS, OR IN HAZARDOUS AREAS SHALL BE INTERMEDIATE STEEL
CONDUIT (IMC). ALL EXTERIOR CONDUIT IN SLAB SHALL BE PVC. ALL CONDUIT
OTHER THAN SPECIFIED TO BE IMC OR PVC SHALL BE ELECTRICAL METALLIC
TUBING (EMT).
4. ALL CONDUIT SHALL BE ROUTED ABOVE CEILINGS, BELOW FLOORS, OR
WITHIN WALLS. NO CONDUIT SHALL BE EXPOSED UNLESS APPROVED BY THE
ARCHITECT.
5. PROVIDE PULL STRINGS IN ALL CONDUIT AND PULLBOXES AS REQUIRED.
ALL CONDUITS SHALL HAVE PLASTIC BUSHINGS INSTALLED AT OPEN ENDS
PRIOR TO PULLING WIRE.
6. ALL BACKBOXES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED.
7. ALL BACKBOXES MOUNTED WITHIN FIRE RATED PARTITIONS SHALL MEET
THE FIRE RATING OF THE PARTITION AS REQUIRED BY CODE.
8. COORDINATE THE EXACT LOCATION OF ALL PULL AND BACKBOXES WITH
ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.
9. ALL JUNCTION AND PULLBOXES SHALL BE PROVIDED WITH ACCOMPANYING
BLANK COVER PLATE.
10. JUNCTION BOXES LOCATED ABOVE DOORS WITH NO ACCESSIBLE CEILING
SHALL BE SECURED WITH TAMPER PROOF SCREWS.
11. PROVIDE WATERTIGHT SEALING ASSEMBLIES WITH PRESSURE BUSHING AS
REQUIRED FOR EXTERIOR PENETRATIONS.
12. JUNCTION AND PULLBOXES IN EXTERIOR LOCATIONS SHALL BE
WATERPROOF.
13. ALL CABLE RUNS IN CEILING AREAS WHERE CONDUIT OR CABLE TRAY IS
NOT SPECIFIED SHALL BE SUPPORTED WITH SIMILAR SUPPORT OR WITH THE
USE OF J-HOOKS AT 5' INTERVALS ABOVE CEILING TILES.
14. COORDINATE WITH ELECTRICAL CONTRACTOR FOR SECURITY DEVICE AND
CONTROL PANEL POWER REQUIREMENTS.
15. WIRE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION. ALL
TERMINATIONS SHALL MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 0.5" OR
LESS OF FINAL TERMINATION. ALL WIRES SHALL BE LABELED WITHIN 6.5" OF
FINAL TERMINATION. ALL LABELS SHALL BE MACHINE PRINTED OR STENCILED.
NO HAND LETTERED LABELS SHALL BE USED.
16. ANY CONDUIT ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO
REPRESENT INSTALLED PATHS OR DISTANCES. ACTUAL ROUTING AND BOX
LOCATIONS SHALL BE FIELD VERIFIED AND COORDINATED WITH OTHER
DISCIPLINES BY THE INSTALLING CONTRACTOR.
1. ALL DEVICES, WIRING, TERMINATION AND OTHER REQUIRED ROUGH-IN
NOT DESIGNATED "AS BY OTHERS", ARE TO BE PROVIDED BY THE
SECURITY CONTRACTOR.
2. ALL SECURITY DEVICES PROVIDED BY THE SECURITY CONTRACTOR.
NOTES BELOW INDICATE WORK BY THE ELECTRICAL CONTRACTOR.
3. PROVIDE 4" X 4" X 2-1/4" DEEP BOX WITH SINGLE GANG DEVICE RING
JB FLUSH MOUNTED 48" A.F.F WITH 3 /4" CONDUIT STUBUP TO J1 BY
ELECTRICAL CONTRACTOR.
4. STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE
HINGE SIDE OF THE DOOR BACK BOX EL TO JUNCTION BOX J1 LOCATED
ABOVE ACCESSIBLE CEILING, BY ELECTRICAL CONTRACTOR.
5. STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE
STRIKE SIDE OF THE DOOR ES TO JUNCTION BOX J1 LOCATED ABOVE
ACCESSIBLE CEILING, BY ELECTRICAL CONTRACTOR.
DEVICE
DETAIL NUMBER
DETAIL NUMBER
DEVICE TYPE
CAM = CCTV CAMERA
DEVICE TYPELEVEL
DEVICE
RISER POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR TO PROVIDE A
HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO
SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18"
A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS
RISER POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR TO PROVIDE A
HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED
TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18"
A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS.
SECURITY CONTROL/EQUIPMENT ROOM POWER (EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TO SECURITY WITHIN A 4" X 4" BOX
SURFACE MOUNTED BEHIND THE CONSOLE/RACK AT 18" AFF WITH WIRE ENDS
TERMINATED AND INSULATED WITH WIRE NUTS.
MAGNOTOMETER/X-RAY SCANNER POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET CONNECTED TO A
120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL
BE FLUSH MOUNTED IN THE FLOOR.
EXTERIOR CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION
SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING
ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE
NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR
ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH
CAMERA'S ACTUAL LOAD SHALL BE 5A AT 120VAC. FOR EXTERIOR LOCATION
PROVIDE POWER IN 4"X4"OUTDOOR RATED BOX
POLE MOUNTED CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-
EMERGENCY CIRCUIT DEDICATED TO SECURITY PROVIDED WITHIN A NEMA 4X
ENCLOSURE MOUNTED AT THE BASE OF THE POLE WITH WIRE ENDS TERMINATED
AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED
OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 15
CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE 1A AT 120VAC.
ELECTRIC EXIT DEVICE POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR
SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT
DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT DEVICES PROVIDED
WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ADJACENT TO THE DOOR
OR AS SHOWN ON DRAWINGS WITH WIRE ENDS TERMINATED AND INSULATED WITH
WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR
ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL.
EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC.
X-RAY/METAL DETECTOR POWER (EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC
20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE
FLUSH MOUNTED IN FLOOR.
ELEVATOR SECURITY EQUIPMENT POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTIONS TO A 120VAC 20A NON-
EMERGENCY CIRCUIT DEDICATED TO SECURITY IN THE ELEVATOR MACHINE ROOM(S)
AS INDICATED ON THE DRAWINGS. TYPICAL LOAD FOR EACH CIRCUIT SHALL BE 10A.
PROVIDE CONNECTION IN A SURFACE MOUNTED BOX MOUNTED AT 8' A.F.F. WITH WIRE
ENDS TERMINATED AND INSULATED WITH WIRE NUTS
UPS POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE A
HARD WIRED CONNECTION TO A 240VAC 65A EMERGENCY CIRCUIT DEDICATED TO
SECURITY AS INDICATED ON THE DRAWINGS. THE CONNECTION SHALL BE PROVIDED
WITHIN A 4" X 4" BOX SURFACE MOUNTED IN THE BACK OF THE SECURITY EQUIPMENT
RACK, 18" A.F.F. AND SHALL HAVE WIRE ENDS TERMINATED AND INSULATED WITH
WIRE NUTS.
VEHICLE GATE POWER (EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL
PROVIDE A DEDICATED 120V AC HARD WIRED 20AMP CIRCUIT WITHIN THE GATE
HOUSING. THE JUNCTION BOX SHALL BE OUTDOOR RATED. THE ELECTRICAL
CONTRACTOR SHALL PROVIDE SURGE PROTECTION FOR THE CIRCUIT EACH GATE
SHOULD HAVE A DEDICATED CIRCUIT MULTIPLE GATES SHOULD NEVER SHARE
CIRCUIT.
SITE POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL CONTRACTOR SHALL PROVIDE
AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON-EMERGENCY CIRCUIT
DEDICATED TO SECURITY. THE OUTLET SHALL BE WALL MOUNTED 12" AAF.
ELECTRIC EXIT DEVICE POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A UN-
SWITCHED CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT
DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING
ADJACENT TO THE DOOR OR AS SHOWN ON DRAWINGS WITH WIRE ENDS
TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE
BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL
NOT EXCEED 10 CONNECTIONS TOTAL. EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A
AT 120VAC.
SECURITY EMERGENCY CALL STATION POWER (EMERGENCY CIRCUIT) HARD WIRE
TO 120VAC 20A CIRCUIT EMERGENCY CIRCUIT DEDICATED FOR EMERGENCY CALL
STATIONS. MOUNTING HT OF CALL BOX TO BE 36" AFF TO BOTTOM OF UNIT. POWER
TO BE BROUGHT DOWN IN COLUMN TO 4" X 4" BOX TO ALIGN WITH 3/4" KO ON BACK
OF UNIT. 5 UNITS CAN BE POWERED FROM SAME CIRCUIT.
ELEVATOR CAMERA POWER (NON-EMERGENCY CIRCUIT) ELEVATOR CONTRACTOR
SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON-
EMERGENCY CIRCUIT DEDICATED FOR THE SECURITY CAMERA. THE OUTLET SHALL BE
MOUNTED ABOVE THE CAB AND PROVIDE ADEQUATE SPACE FOR A PLUG IN TYPE
TRANSFORMER.
INTERIOR PTZ CAMERA POWER (NON-EMERGENCY CIRCUIT) ELECTRICAL
CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION
SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING
ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE
NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR
ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH
CAMERA POWER SUPPLY ACTUAL LOAD SHALL NOT EXCEED 3A AT 120VAC.
ACCESS CONTROL READER
ACCESS CONTROL PANEL
ACCESS CONTROL SERVER
ANNUNCIATOR
ALARM PANEL
DOOR INTERLOCK
DOOR INTERFACE UNIT
DOOR RELEASE
DIGITAL VIDEO RECORDER
GLASS BREAK SENSOR
HEAD END MONITORING LOCATION
INTERCOM
INFRARED BEAM
ALARM KEYPAD
FIRE RELAY (FOR LOCK RELEASE)
LOCAL ALARM
MAGNETIC CONTACT
MOTION DETECTOR
MAGNETIC HOLD OPEN
VIDEO SURVEILLANCE
NETWORK VIDEO RECORDER
PUSH BUTTON
REQUEST TO EXIT
RELAY IN/OUT
SECURITY BADGE PRINTER
SECURITY RISER LOCATION
SIREN/SOUNDER
STROBE
VIDEO INTERCOM
VIDEO ENCODER
VIBRATION SENSOR
WORKSTATION
LOCK POWER SUPPLY
CAMERA POWER SUPPLY
DEVICE POWER SUPPLY
CCTV CAMERA - FIXED
CCTV CAMERA - PTZ
CCTV CAMERA - CEILING MOUNT
CCTV CAMERA - WALL MOUNT
CCTV CAMERA - CORNER MOUNT
CCTV CAMERA - CORNER MOUNT
PROVIDE 4" X 4" X 2-1/4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE
CEILING UNLESS OTHERWISE NOTED.
PROVIDE 6" X 6" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING
UNLESS OTHERWISE NOTED.
PROVIDE 10" X 10" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING
UNLESS OTHERWISE NOTED.
PROVIDE 12" X 12" X 6" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING
UNLESS OTHERWISE NOTED.
PROVIDE 16" X 16" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING
UNLESS OTHERWISE NOTED.
PROVIDE 20" X 20" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING
UNLESS OTHERWISE NOTED.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
XX-XXX
DEVICE TYPE
AC-X
DETAIL NUMBER
LEVEL DEVICE NUMBER
DRAWING LIST: ABBREVIATIONS: SECURITY ELECTRICAL NOTES: SYMBOLS:GENERAL NOTES:
SECURITY CONDUIT AND WIRING NOTES:
EQUIPMENT SYMBOL & TAG DEFINITIONS: SECURITY DEVICE NOTES:
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
12" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
1
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY COVER
SHEET
TY-000
NUMBER NAME
TY-000 SECURITY COVER SHEET
TY-102 SECURITY OVERALL PLAN - LOWER LEVEL
TY-103 SECURITY PART PLAN - UPPER LEVEL NORTH
TY-104 SECURITY PART PLAN - UPPER LEVEL SOUTH
TY-300 SECURITY RISER DIAGRAM
TY-400 SECURITY DEVICE DETAILS
DN
A
B
C
DN
C
-
3
C
-
1
7
C - 1
C
-
3
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
?
?
CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
?
132A 132B
MC - 2
AC - 71
AC - 71
MC - 1
MC - 1
MD - 4
MC - 1
AC - 72KP-1
MC - 2
MD - 4
KP-1
KP-1
MD - 4
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
2
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY OVERALL
PLAN - LOWER
LEVEL
TY-102
1/8" = 1'-0"1 SECURITY OVERALL PLAN - LOWER LEVEL PARENT
A
B
CC -
1
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
?
?
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
?
?
MC - 1
TT-200
1
TYP
W - 1
NVR
HE
PROVIDE ENCODER FOR
DIGITAL SIGNAGE THROUGH
VMS, MON BY DIV-27
WS
AC - 1
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
4
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY PART
PLAN - UPPER
LEVEL NORTH
TY-103
1/8" = 1'-0"1 SECURITY PART PLAN - UPPER LEVEL NORTH
A
B
CC -
1
C
-
1
C - 1
C - 4
C - 4
C
-
1
7
3 4 5 6 7
AH
6.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13
E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205M. LOCKERS
231
W. TOILETS
223
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201
LOBBY
202
?
?
POOL STORAGE
255 CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254 GUARDS
258
?
?
?
?
?
?
M. TEAM LOCKER
A107
W. TEAM
LOCKERS
A106
POOL STORAGE
A108
EXIST
NATATORIUM
A110
EXIST POOL
MECH
A112
EXIST POOL
EQUIP
A114
EXIST LAUNDRY
A111
EXIST ELEC
A113
FOYER
A101
MECHANICAL
A102
?
?
M. SHOWERS
232
M. TOILETS
233
W. LOCKERS
221
EXIST POOL DECK
A109
A115A
A114A
A115B
A114B
A112
A113
XA110
?
?
253B 255
?
256
254B
?
MD - 1
MC - 1
MC - 1
MC - 1
MC - 2 AC - 72
MC - 1
MD - 4
KP-1
PROVIDE ENCODER FOR
DIGITAL SIGNAGE THROUGH
VMS, MON BY DIV-27
MC - 2
WS
MC - 1
MC - 2
KP-1
AC - 72MON
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
6
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY PART
PLAN - UPPER
LEVEL SOUTH
TY-104 1/8" = 1'-0"1 SECURITY PART PLAN - UPPER LEVEL SOUTH
LAN 276
AC-X AC-X
DOOR DOOR
ACCESS
CONTROL
PANEL
MC-X
DOOR
MC-X
DOOR
MC-X
DOOR
MC-X
DOOR
AC-X AC-X
DOOR DOOR
MC-X
DOOR
MC-X
DOOR
MC-X
DOOR
MC-X
DOOR
MD-X
ROOM
MC-X
DOOR
MD-X
ROOM
MC-X
DOOR
LAN 276
INTRUSION
DETECTION
PANEL
LAN 276
NETWORK
SWITCH
(FBO)
KP-X
ROOM
KP-X
ROOM
SECURITY CCTV TYPICAL DEVICE RISER DIAGRAM1SCALE: NTS
LEVEL 1
H H
ACCESS CONTROL TYPICAL DEVICE RISER DIAGRAM3SCALE: NTS
LEVEL 2
Y Y A AA A
Y Y A AA A
LEVEL 1
LEVEL 2
H H
INTRUSION DETECTION TYPICAL DEVICE RISER DIAGRAM2SCALE: NTS
LEVEL 2
LEVEL 1
B A
B A
LAN (FBO)
INTERFACE
TO IDS
INTERFACE
TO ACS
Y-1
Y-1
C-X
CAM-01-##
C-X
CAM-01-##
C-X
CAM-01-##
C-X
CAM-01-##
WCW#991380-S-PL4-Conductor #16 AWG/STRD/NO SHIELD
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
-PL
Y4-
Y3-
Y2-
Y1-
WCW#442360-S
2-COND/ 12AWG/STRD
8 COND/ 18AWG/STRD/SHLD w/ DRAIN
WCW COMPOSITE CABLE
*SPECIFY RISER OR PLENUM
2 COND/ 18 AWG/STRD/TWST/SHLD w/ DRAIN
3 PR/ 18AWG/STRD/TWST/SHLD w/DRAIN
Y-
N -
O -
P -
Q -
8-Conductor #18 AWG/STRD/SHLD/w/DRAIN
6-Conductor #18 AWG/STRD/NO SHIELD
4-Conductor #22 AWG/STRD/NO SHIELD
WCW#762380-S
WCW#4150102-S
WCW#160100-S
WCW#555619-S
WCW#659211-S
WCW#441367-S
WCW#043106AL-S
WCW#444351-03S
WCW#042003-S
WCW#442380-S
WCW#444366-S
WCW#4160201
WCW#714510-VNQ
WCW#002352-S-PL
WCW#444381-S-PL
WCW#U002391-11S-PL
WCW#160100-PL
WCW#414104-S
CABLE DESCRIPTION PART NUMBER
4 COND/ 18AWG PARALLEL MID-CAP
M -
L -
CABLE TYPES
K -
I -
H -
G -
F -
E -
D -
C -
B -
A -
J -
2-COND/ 22AWG/STRD/TWST
2 PR/ 22AWG/STRD/TWST/SHLD w/ DRAIN
4 COND/ 18 AWG/STRD/TWST/SHLD w/ DRAIN
2 PAIR EA. PR Shielded 18AWG.
CATEGORY 6 LAN CABLE
RG-59U COAX
2 COND/ 16 AWG/STRD/TWST
1 PR/ 22 AWG/STRD/TWST/SHLD w/ DRAIN
WCW COMPOSITE CABLE
PN# CBORD-A-AC-PL-EXT
6 COND/ 22 AWG/STRD/TWST/SHLD w/ DRAIN
2 PR/ 24 AWG/STRD/TWST/SHLD w/ DRAIN
4 COND/ 18 AWG/STRD/TWST
2 COND/ 18 AWG/STRD/TWST
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
3/16" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
6
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY RISER
DIAGRAM
TY-300
FINISHED FLOOR
FINISHED CEILING
SECURE SIDE
ACCESS CONTROL - SINGLE DOOR - CARD READER,
ELECTRIFIED MORTISE LOCK, DOOR POSITION SWITCH
6"
CEILING SLAB
7
1
2
3
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING
- DOOR CONTACT (RECESSED)
- ELECTRIFIED MORTISE LOCK, FREE EGRESS (INTERGRATED REQUEST TO EXIT)
4 - WIRE TRANSFER HINGE
5 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON
HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX
6 - STUB 3/4" CONDUIT WITH DRAG LINE.
J1
3'-2"
-- DOOR CLOSER AS PART OF DOOR HARDWARE (TYPE NOT SPECIFIED)
8 - 3/4" CONDUIT WITH DRAG LINE TO NEAREST ACCESSIBLE CEILING TO CABLE TRAY
TYPICAL PLAN VIEW
- ACCESS CONTROL (TYPE?????) PROVIDE SINGLE GANG BACK BOX, MOUNTED 3'-2"
AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS
AC-1
134
2
5
7
8
6
6
12
4
3
C-1
DETAIL NOTES:
1. FIXED POE DOME CAMERA
2. TELECOM OUTLET 8 PIN JACK INSIDE PLENUM RATED GEM BOX
3. CAMERA PATCH CORD
4. HORIZONTAL 4-PAIR UTP CABLE WITH 20' SLACK
5. J-HOOK
6. 1" DIAMETER HOLE
#
VIDEO SURVEILLANCE - FIXED IP DOME - FLUSH OR SURFACE - INTERIOR
FINISHED CEILING
DETAIL NOTES:
1. FIXED POE DOME CAMERA
2. TELECOM OUTLET 8 PIN JACK
3. HORIZONTAL 4-PAIR UTP CABLE
4. 3/4" EMT CONDUIT
5. BACK BOX (J#), BACK BOX TO BE SECURED TO STRUCTURE.
#
INACCESSIBLE CEILING MOUNTED - INTERIOR
DETAIL NOTES:
1. REFER TO SPECIFICATION 28 23 29 FOR
CAMERA MODEL REQUIREMENTS.
2. REFER TO CONTRACTOR RESPONSIBILITY
LEGEND ON TY-000.
3. REFER TO XXXXX FOR CAMERA VIEW TYPE
(RECOGNITION/IDENTIFICATION/DETECTION)
INSTALLATION DESCRIPTION
CAMERA IS INSTALLED ONTO THE BACK BOX
VIA CONVERTER PLATE. THE GANG BOX
ITSELF IS EITHER ON THE SURFACE OF THE
HARD CEILING OR INSIDE THE CEILING.
ACCESSIBLE CEILING MOUNTED - INTERIOR
FINISHED CEILING
CEILING SLAB CEILING SLAB
3
2
5
4
6
1
2 3
5
1
4
#
C-17
DETAIL NOTES:
1. PENETRATION IN WALL FILLED WITH APPROVED SEALANT
2. CCTV fIXED CAMERA IN ENVIRONMENTAL HOUSING MOUNTED
16' MINIMUM (INTERIORS),
20' MINIMUM (EXTERIOR)
4. EXTERIOR WALL
5. 6"x6"x4" DEEP BOX BY (BY ELECTRICAL CONTRACTOR).
6. IP JUMPER CABLE BY SECURITY CONTRACTOR.
7. 3/4" CONDUIT TO NEAREST ACCESSIBLE CEILING OR CABLE TRAY (BY
ELECTRICAL CONTRACTOR).
3. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR).
6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR).
VIDEO SURVEILLANCE - FIXED IP DOME - WALL
PENDANT MOUNTED - EXTERIOR
7
3
6
5
4
2
1
AC-71
FINISHED CEILING
CEILING SLAB
FINISHED FLOOR
TO 120VAC
PROTECTED SIDE
TYPICAL PLAN VIEW
FA
6"TYP.
3'-2"
J1
1
4
1
9
2
3
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
- DOOR CONTACT (RECESSED)
4 - WIRE TRANSFER HINGE (EPT 10)
7 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON
HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX
8 - STUB 3/4" CONDUIT WITH DRAG LINE.
5 - REQUEST TO EXIT, PUSH BUTTON
6 - BREAK GLASS UNIT
1
-- DOOR CLOSER AS PART OF IRONMONGERY (TYPE NOT SPECIFIED)
- CARD READER (PROXIMITY/SWIPE) PROVIDE SINGLE GANG BACK BOX,
MOUNTED 3'-2" AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS
- FIRE EXIT HARDWARE (W/REQUEST TO EXIT)
3
4 3
ACCESS CONTROL - SINGLE DOOR - CARD READER,
ELECTRIFIED EXIT DEVICE, DOOR POSITION SWITCH
8
2
LPS
AC-72
FINISHED CEILING
CEILING SLAB
FINISHED FLOOR
TO 120VAC
PROTECTED SIDE
TYPICAL PLAN VIEW
FA
6"TYP.
3'-2"
J1
1
2
4
1
9
2
3
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
- DOOR CONTACT (RECESSED)
4 - WIRE TRANSFER HINGE (EPT 10)
7 - STUB 3/4" CONDUIT OR GREENFIELD WITH DRAG LINE DOWN DOOR FRAME ON
HINGE SIDE OF THE DOOR. BACK BOX TO JUNCTION BOX
8 - STUB 3/4" CONDUIT WITH DRAG LINE.
5 - REQUEST TO EXIT, PUSH BUTTON
6 - BREAK GLASS UNIT
1
-- DOOR CLOSER AS PART OF IRONMONGERY (TYPE NOT SPECIFIED)
- CARD READER (PROXIMITY/SWIPE) PROVIDE SINGLE GANG BACK BOX,
MOUNTED 3'-2" AFF AND 3" TO 12" FROM DOOR FRAME DEPENDING ON FIELD CONDITIONS
- FIRE EXIT HARDWARE (W/REQUEST TO EXIT)
33
4 4
4
3 3
ACCESS CONTROL - DOUBLE DOOR - CARD READER,
ELECTRIFIED EXIT DEVICE, DOOR POSITION SWITCH
8
LPS
#
C-3
DETAIL NOTES:
1. CAMERA BACK BOX (PROVIDED BY SECURITY CONTRACTOR)
2. TOGGLE BOLTS (AS REQUIRED)
3. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR).
6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR).
4. CEILING SOFFIT
5. CAMERA
6. IP JUMPER CABLE (BY SECURITY CONTRACTOR).
7. 3/4" CONDUIT TO NEAREST ACCESSIBLE CEILING OR CABLE TRAY (BY ELECTRICAL
CONTRACTOR).
VIDEO SURVEILLANCE - FIXED IP DOME - WALL
FLUSH MOUNTED - INTERIOR
5
7
3
4
2
1
6
#
C-4
DETAIL NOTES:
1. CAMERA BACK BOX (PROVIDED BY SECURITY CONTRACTOR)
2. IP DATA JACK PROVIDED (BY TELECOM. CONTRACTOR).
6"x6"x4" JUNCTION BOX (BY ELECTRICAL CONTRACTOR).
3. CEILING
4. CAMERA
5. IP JUMPER CABLE (BY SECURITY CONTRACTOR).
6. 3/4" CONDUIT TO NEAREST ACESSIBLE CEIILING OR CABLE TRAY (BY ELECTRICAL
CONTRACTOR).
VIDEO SURVEILLANCE - FIXED IP DOME - WALL
SURFACE MOUNTED - INTERIOR
4
1
5
6
3
7
FINISHED FLOOR
FINISHED CEILING
MAGNETIC CONTACT - SINGLE DOOR - FLUSH MOUNTED
6"
CEILING SLAB
3
1
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
3
- DOOR CONTACT (RECESSED)
1
2
2 - STUB 3/4" CONDUIT WITH DRAG LINE.
2
J1
4 - STUB 3/4" CONDUIT WITH DRAG LINE TO NEAREST CABLE TRAY OR
ACCESSIBLE CEILING.
4
TYPICAL PLAN VIEW
SECURE SIDE
MC-1
6"TYP.
MAGNETIC CONTACT - DOUBLE DOOR - FLUSH
MOUNTED
J1
4
3
2 2
SECURE SIDE
FINISHED FLOOR
FINISHED CEILING
CEILING SLAB
2
11
3
1
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
- DOOR CONTACT (RECESSED)
2 - STUB 3/4" CONDUIT WITH DRAG LINE.
4 - STUB 3/4" CONDUIT WITH DRAG LINE TO NEAREST CABLE TRAY OR
ACCESSIBLE CEILING.
TYPICAL PLAN VIEW
MC-2
KP-1
3
3
4
4
1
2
1
2
4'-6"
- PANIC BUTTON (PUSH BUTTON TYPE)
DEEP BOX MOUNTED ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
- PROVIDE 4" x 4" x 2 1/8" DEEP JUNCTION BOX OR 6"x 6"x 4"
- STUB 3/4" CONDUIT WITH DRAG LINE.
NOTE:
REVIEW KEYPAD LOCATION WITH CONSULTANT AND ARCHITECT PRIOR TO INSTALLATION.
- 3/4" CONDUIT WITH DRAG LINE TO NEAREST ACCESSIBLE CEILING TO CABLE TRAY.
FINISHED CEILING
KEYPAD - WALL MOUNTED - FLUSH
FINISHED FLOOR
CEILING SLABJ1
MD-1
STRUCTURAL SUPPORT TO
BUILDING PER NEC
NOTE:
REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR EXACT DEVICE LOCATIONS.
CONDUIT AND CABLE
PER DWGS AND SPECS.
TO CABLE TRAY.
INFARARED MOTION DETECTOR PER SPECS.
GWB OR CEILING
PER ROOM FINISH
SCHEDULE.
MOTION DETECTOR - CEILING MOUNTED - FLUSH
STANDARD OCTAGONAL OR 4"
SQUARE J-BOX
TO MATCH WITH DETECTOR.
NOTE:
REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR EXACT DEVICE
LOCATIONS.
WALL PER ROOM
FINISH
SCHEDULE.
MOTION DETECTOR - WALL MOUNTED - SURFACE
STANDARD OCTAGONAL OR 4"
SQUARE
J-BOX
TO MATCH WITH DETECTOR.
MD-4
CONDUIT AND CABLE PER DWGS
AND
SPECS.
INFARARED MOTION
DETECTOR PER
SPECS.
TO CABLE TRAY.
(4')
ACCESS
CONTROL
POWER
SUPPLY
ACCESS
CONTROL PANEL
LOCK POWER
SUPPLY
FLOOR SLAB
FLOOR SLAB
(8')
DUPLEX OUTLET WITH 120VAC
20AMP
DEDICATED CIRCUITS ON
EMERGENCY
POWER.
FIRE TREATED PLYWOOD
BACKBOARD, SIZED AS
NOTED.
WIRE TROUGH
(TYPICAL FOR 2)
POWER STRIP (6 OUTLETS MIN).
DETAIL NOTES:
CLASS E
FIRE RELAY
TYPICAL SECURITY WALL FIELD ELEVATION
3
1
2
1
4
2
4
3
1
W-1
ACCESS
CONTROL
PANEL (AS
REQUIRED)
INTRUSION
DETECTION
ALARM
PANEL
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
3/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
2
:
1
8
:
0
8
P
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SO
NF
10-17-2016
16003
SECURITY DEVICE
DETAILS
TY-400