HomeMy WebLinkAboutPLANS 660 Community Dr Telecom Plans 2016-10-171. CABLE ADMINISTRATION:
A. PROPERLY LABEL ALL CABLES, RECEPTACLES, CONNECTION BLOCKS, GROUNDING BARS,
RACKS, CABINETS, OUTLETS AND PATCH PANELS.
B. LABEL EACH CABLE THAT EXCEEDS 250 FT. (75m), THE CABLE SHALL BE CLEARLY MARKED
WITH RED TAPE AT BOTH ENDS OF EACH CABLE INDICATING THE EXACT CABLE LENGTH AND
NOTED IN THE REQUIRED AS-BUILT LABEL REPORT.
C. PRIOR TO SYSTEM ACCEPTANCE, THE CONTRACTOR SHALL SUBMIT AN AS-BUILT LABEL
REPORT PROVIDING THE ROOM NUMBERS AND CABLE LENGTHS FOR EACH OF THE INSTALLED
CABLES.
2. LABEL REQUIREMENTS:
A. PROVIDE WHITE LABEL WITH TYPEWRITTEN LEGIBLE CHARACTERS. PRINTED WITH NON-
SMEAR TYPE INK. HANDWRITTEN LABELS ARE NOT PERMITTED.
B. PROVIDE LABELS WITH A SELF ADHESIVE BACKING.
C. PROVIDE LABELS FOR CABLES WITH PROTECTIVE WRAP-AROUND PLASTIC TRANSPARENT
COVER WHICH WILL SERVE TO PROTECT THE INK FROM SMEARING AND SECURE THE LABEL
TO THE CABLE.
D. PROVIDE LABELS FOR CABLES WIDE ENOUGH FOR 23 CHARACTERS IN A SINGLE ROW.
E. RISER AND TIE CABLES JACKETS SHALL BE LABELED WITHIN EACH TECHNOLOGY ROOM AND
AT 50 FT. (15m) INTERVALS OUTSIDE TECHNOLOGY ROOMS ABOVE CEILINGS.
1. INSTALL FIRESTOP TO ALL SLAB AND WALL PENETRATIONS PROVIDED FOR THE INSTALLATION
OF TELECOMMUNICATIONS CABLE AS REQUIRED TO MAINTAIN FIRE RATING OF SLAB OR WALL.
REVIEW ARCHITECT'S PLANS FOR PARTITION TYPES.
2. CABLE TERMINATION HARDWARE INDICATED ON RACK ELEVATIONS MAY BE APPROXIMATE TO
INDICATE TYPICAL ORGANIZATION OF TERMINATION HARDWARE. CONTRACTOR SHALL
COMPARE THE RACK ELEVATIONS TO THE CABLING REQUIRED BY THE CONTRACT DOCUMENTS
AND FURNISH AND INSTALL TERMINATION HARDWARE IN SUFFICIENT QUANTITIES TO
TERMINATE CABLES.
1. INSTALL TELECOMMUNICATIONS WIRING TO MAINTAIN A MINIMUM OF 5" SEPARATION FROM
FLUORESCENT LIGHTING.
2. PROVIDE DESIGNATION LABELS FOR ALL TERMINATION BLOCKS, PATCH PANELS, AND
WORKSTATION OUTLET FACEPLATES.
3. PROVIDE CABLE STRAPS NO GREATER THAN 5' APART TO SUPPORT CABLES WHERE NO CABLE
TRAYS AND CONDUITS ARE PROVIDED.
4. INSTALL EACH CABLE SET INDICATED BY THE SYMBOLS LIST FROM THE OUTLET LOCATION TO
THE RESPECTIVE SERVING TELECOM ROOM.
5. REPORT TO THE OWNER AND DESIGN TEAM ANY HORIZONTAL CABLE THAT EXCEEDS 250 FT.(75m)
6. DO NOT RUN LOW-VOLTAGE CABLE DIRECTLY PARALLEL TO ELECTRICAL OR GROUND WIRE
SHOULD THIS CONDITION ARISE, REPORT TO THE OWNER AND THE DESIGN TEAM. IF CABLES
MUST CROSS, DO SO AT PERPENDICULAR ANGLES.
1. COORDINATE WALL BOX LOCATIONS AND DIMENSIONS WITH ARCHITECTURAL AND ELECTRICAL
PLANS.
2. COORDINATE WITH ELECTRICAL DRAWINGS FOR LOCATION OF ALL TELECOMMUNICATIONS
OUTLETS.
3. INSTALL CONDUIT AND LADDER RACK FOR TELECOMMUNICATIONS WIRING TO MAINTAIN A
MINIMUM OF 5" SEPARATION FROM FLUORESCENT LIGHTING.
4. COORDINATE INSTALLATION OF CONDUITS AND CABLE TRAYS WITH OTHER COMPONENTS
INSTALLED WITHIN CEILING. PREPARE SHOP DRAWINGS TO DEMONSTRATE AND ENSURE
PROPER INSTALLATION OF ALL COMPONENTS.
5. IF CONFLICTS ARE FOUND BETWEEN THE TELECOMMUNICATIONS DRAWINGS AND ANY OTHER
DRAWINGS ASSOCIATED WITH THE PROJECT, NOTIFY THE ARCHITECT AT ONCE AND HAVE
LOCATION VERIFIED BEFORE OUTLETS ARE INSTALLED. ANY REASONABLE CHANGE IN
LOCATION OF OUTLETS PRIOR TO ROUGHING SHALL NOT INVOLVE ADDITIONAL EXPENSE TO
THE OWNER. THE TERM "REASONABLE" SHALL BE INTERPRETED AS MOVING OUTLET
LOCATIONS A MAXIMUM OF 10' IN ANY DIRECTION FROM THE LOCATION INDICATED ON THE
DRAWINGS.
6. MAINTAIN MINIMUM BEND RADIUS OF 10X O.D. FOR CONDUITS GREATER THAN 2" DIAMETER.
MAINTAIN MINIMUM BEND RADIUS OF 6X O.D. FOR CONDUITS EQUAL TO OR LESS THAN 2"
DIAMETER.
7. PROVIDE PULL BOXES (SIZE AS NOTED) AFTER EVERY 100 FT. (30m) OF RUN OR AFTER EVERY
180-DEGREES OF BEND.
8. DO NOT INSTALL PULL BOXES IN LIEU OF A BEND.
9. REAM AND BUSH THE ENDS OF ALL CONDUITS.
10. PROVIDE AND LEAVE IN PLACE A PULL STRING IN EACH CONDUIT.
11. STUB UP CONDUIT SLEEVES THROUGH SLABS 3" ABOVE FINISHED FLOORS.
12. PROVIDE HANGERS, ANCHORS, MOUNTING HARDWARE, GROUND LUGS AND STRAPS AS
REQUIRED TO ENSURE PROPER INSTALLATION OF PATHWAY COMPONENTS. INSTALL ALL
COMPONENTS AS PER MANUFACTURERS RECOMMENDATIONS AND PER ALL APPLICABLE
CODES.
13. GROUND ALL CONDUITS AND LADDER RACK AS PER MANUFACTURERS' RECOMMENDATIONS
AND PER ALL APPLICABLE CODES.
14. PROVIDE AT ALL LADDER RACK AND CABLE TRAY LOCATIONS: RUNWAY DROPOFFS, SPLICE
HARDWARE, GROUND STRAPS, THERMAL EXPANSION PLATES, TERMINATION KITS, END
SUPPORT KITS AND CEILING SUPPORT HARDWARE.
15. PROVIDE FOR ALL BASKET TYPE CABLE TRAY LOCATIONS; CONNECTION HARDWARE, GROUND
STRAPS, THERMAL EXPANSION PLATES, SUPPORT BRACKETS AND CEILING SUPPORT HARDWARE.
16. REFER TO DISTRIBUTION PLANS FOR REQUIREMENTS FOR JUNCTION BOX AND CONDUITS TO
SUPPORT WORKSTATION OUTLETS.
17. WHERE CABLE IS RUN ABOVE NON-ACCESSIBLE (I.E. GYPSUM BOARD) CEILING CONSTRUCTION,
CONDUIT AND PULLBOXES MUST BE INSTALLED TO PROPERLY ROUTE CABLE.
18. PROVIDE J-HOOKS AND CABLE STRAPS TO SUPPORT CABLE ABOVE ACCESSIBLE CEILING
CONSTRUCTION, EXCEPT IN AREAS WHERE CABLE TRAY OR CONDUIT IS INDICATED.
19. PROVIDE WOVEN FIBER RACEWAY COMPLETE WITH DRAG LINE FOR ALL 2", 3", AND 4" CONDUITS
PER SPECIFICATIONS AND DRAWING DETAILS, UON.
AFF - ABOVE FINISHED FLOOR
AV - AUDIOVISUAL
C - CONDUIT
CAT-3 - TIA CATEGORY 3 RATED
CAT-5E - TIA CATEGORY 5e RATED
CAT-6 - TIA CATEGORY 6 RATED
CAT-6A - TIA/EIA CATEGORY 6A RATED
CLG - CEILING
COAX - COAXIAL CABLE
CP - CONSOLIDATION POINT
FO - FIBER OPTIC
F/UTP - FOILED / UNSHIELDED TWISTED PAIR
GND - GROUND
IC - INTERMEDIATE CROSS-CONNECT
ID - INSIDE DIAMETER
IDF - INTERMEDIATE DISTRIBUTION FRAME
J-BOX - JUNCTION BOX
LAN - LOCAL AREA NETWORK
MC - MAIN CROSS-CONNECT
MDF - MAIN DISTRIBUTION FRAME
MH - MANHOLE
MM - MULTIMODE
MTER - MAIN TELECOMMUNICATIONS EQUIPMENT ROOM
NIC - NOT IN CONTRACT
NID - NETWORK INTERFACE DEVICE
NTS - NOT TO SCALE
OD - OUTSIDE DIAMETER
OFE - OWNER FURNISHED EQUIPMENT
OSP - OUTSIDE PLANT
PP - PATCH PANEL
PR - PAIR
PB - PULLBOX
PBX - PRIVATE BRANCH EXCHANGE
RW - RACEWAY
SM - SINGLE MODE
ST - STRAND
STP - SHIELDED TWISTED PAIR
TEMP - TEMPORARY
TGB - TELECOMMUNICATIONS GROUND BAR
TR - TELECOMMUNICATIONS ROOM
TSER - TELECOMMUNICATIONS SERVICE ENTRANCE ROOM
TYP - TYPICAL
UON - UNLESS OTHERWISE NOTED
UPS - UNINTERRUPTIBLE POWER SUPPLY
UTP - UNSHIELDED TWISTED PAIR
VOIP - VOICE OVER INTERNET PROTOCOL
WAN - WIDE AREA NETWORK
WAP - WIRELESS ACCESS POINT
WMO - WIRE MANAGEMENT
WP - WATERPROOF
WS - WORKSTATION
WW - WIREWAY
DRAWING LIST: ABBREVIATIONS: GENERAL INFORMATION FOR ALL SYMBOLS: ENLARGED PLAN SYMBOLS: GENERAL NOTES:
CABLING NOTES:
PATHWAY NOTES:
IDENTIFICATION:
FLOOR BOX OUTLET
# = QUANTITY OF 4-PAIR HORIZONTAL COPPER CABLES
WIRELESS ACCESS POINT OUTLET
(2) 4-PAIR HORIZONTAL COPPER CABLES
AP TO BE OFCI.
SECURITY SURVEILLANCE CAMERA OUTLET
(1) 4-PAIR HORIZONTAL COPPER CABLES
SPECIALITY SYMBOLS:
2 POST STANDARD 19" IT EQUIPMENT RACK, 7' HIGH UON
REFER TO 27 11 16
4 POST STANDARD 19" IT EQUIPMENT RACK, 7' HIGH UON
REFER TO 27 11 16
DOUBLE SIDED VERTICAL CABLE MANAGEMENT PANEL, HEIGHT TO
MATCH RACK HEIGHT UON REFER TO 27 11 23
SINGLE SIDED VERTICAL CABLE MANAGEMENT PANEL, HEIGHT TO
MATCH RACK HEIGHT UON
REFER TO 27 11 23
WALL SPACE RESERVED FOR DESIGNATED EQUIPMENT WHERE ****
REPRESENTS EQUIPMENT DESIGNATION
VERTICAL CONDUIT DOWN
SIZE AS NOTED
REFER TO 27 05 28.33
VERTICAL CONDUIT UP
SIZE AS NOTED
REFER TO 27 05 28.33
INDICATES CABINET FRONT
RACK/CABINET MOUNTED POWER DISTRIBUTION UNIT
* = LETTER DESIGNATING TYPE
REFER TO 27 11 26
TELECOMMUNICATIONS GROUND BUS BAR
REFER TO 27 05 26
TELECOMMUNICATIONS MAIN GROUND BUS BAR
REFER TO 27 05 26
HORIZONTAL CABLE TRAY
SIZE AND TYPE AS NOTED
REFER TO 27 05 28.36
VERTICAL CABLE TRAY
REFER TO 27 05 28.36
HORIZONTAL CONDUIT
SIZE AS NOTED
REFER TO 27 05 28.33
HORIZONTAL PRE FAB FIRE RATED PATHWAY
REFER TO 27 05 28
VERTICAL PRE FAB FIRERATED PATHWAY
REFER TO 27 05 28
PDU-
TGB #
TMGB
****
*
STANDARD INFORMATION OUTLET
# = QUANTITY OF 4-PAIR HORIZONTAL COPPER CABLES
STANDARD SYMBOLS:
# #
INDICATES THE QUANTITY OF HORIZONTAL COPPER CABLES.
INDICATES THE OUTLET MOUNTING HEIGHT IN INCHES AFF. USE PROJECT
STANDARD MOUNTING HEIGHT IF NOT INDICATED. REFER TO
ARCHITECTURAL DRAWINGS FOR STANDARD MOUNTING HEIGHTS.
4-PAIR HORIZONTAL COPPER CABLES SHALL BE CATEGORY 6A (REFER TO 27 15 13)
FRONT
IT EQUIPMENT CABINET, REFER TO 27 11 16
CABINET DOOR, SINGLE LEAF
CABINET SIDE PANELS
CABINET DOORS, SPLIT LEAF
DOUBLE DUPLEX 110 VOLT 20A CONVENIENCE ELECTRICAL OUTLET
SPECIALTY ELECTRICAL OUTLET
NEMA L6-30r RECEPTACLE ON DEDICATED CIRCUIT
* = UPS SYSTEM FEEDING OUTLET
SPECIALTY ELECTRICAL OUTLET
NEMA L21-30r RECEPTACLE ON DEDICATED CIRCUIT
* = UPS SYSTEM FEEDING OUTLET
DUPLEX 110 VOLT 20A CONVENIENCE ELECTRICAL OUTLET
ELECTRICAL SYMBOLS:
*
*
FOR COORDINATION ONLY, NOT FOR CONSTRUCTION, REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION
TELECOM SYMBOL, VARIES
#
PULL BOX SIZING CHART
LENGTH
(in.)
16
DEPTH
(in.)
3
PULL BOX DIMENSIONS
2
DIMENSION TO INCREASE PULL
BOX WIDTH FOR EACH
ADDITIONAL CONDUIT (in.)
3
DIMENSION TO INCREASE PULL
BOX DEPTH FOR EACH ADDITIONAL
TIER OF CONDUIT (in.)WIDTH
(in.)
4
CONDUIT
TRADE
SIZE (in.)
1
20 3 3 361-1/4
27 4 4 481-1/2
36 5 5 482
42 6 6 5102-1/2
48 6 6 5123
54 6 6 6123-1/2
60 8 8 8124
L
W
D
#
#
AP
CAM
J J
J-HOOK CABLING DISTRIBUTION
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
12" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
4
9
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM COVER
SHEET
TT-000
NUMBER NAME
TT-000 TELECOM COVER SHEET
TT-102 TELECOM OVERALL PLAN - LOWER LEVEL
TT-103 TELECOM PART PLAN - UPPER LEVEL
NORTH
TT-104 TELECOM PART PLAN - UPPER LEVEL
SOUTH
TT-112 TELECOM OVERALL RCP - LOWER LEVEL
TT-113 TELECOM PART RCP - UPPER LEVEL NORTH
TT-114 TELECOM PART RCP - UPPER LEVEL SOUTH
TT-200 TELECOM ENLARGED PLAN
TT-300 TELECOM RISERS
TT-400 TELECOM DETAILS SHEET
TT-401 TELECOM DETAILS SHEET
TT-402 TELECOM DETAILS SHEET
DN
A
B
C
DN 1
1
1
1
1
AP
AP
AP
AP
AP
AP
CAM
CAM
CAM
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
?
?
CLASSROOM
114
RECV & STOR
115
?
?
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
1 1
1
1
TELECOM KEYNOTES:
1. ROUGH IN ONLY. BACKBOX AND CONDUIT TO CEILING SPACE
ABOVE.
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
0
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM OVERALL
PLAN - LOWER
LEVEL
TT-102 1/8" = 1'-0"1 TELECOM OVERALL PLAN - LOWER LEVEL
A
B
C
1
1
1
1
1
1
2
2
1
1
2
2
1
1
AP
AP
AP
AP
AP
AP
CAM
4
22
2
2
2
2
2
2
2
2
2
2
22
2
2
2
2
1 1
4
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
?
?
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
TT-200
1
1
1
1
1
1
TELECOM KEYNOTES:
1. ROUGH IN ONLY. BACKBOX AND CONDUIT TO CEILING SPACE
ABOVE.
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
2
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM PART
PLAN - UPPER
LEVEL NORTH
TT-103
1/8" = 1'-0"1 TELECOM PART PLAN - UPPER LEVEL NORTH
1
2
1 2
2
1
2
AP
AP
AP
AP
AP
CAM
CAM
CAM
CAM
4
2
CAM
2
3 4 5 6 7
A4
A5
6.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13
E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205M. LOCKERS
231
W. TOILETS
223
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201LOBBY
202
?
?
POOL STORAGE
255 CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARDS
258
?
?
?
?
?
?
M. TEAM LOCKER
A107
W. TEAM
LOCKERS
A106
POOL STORAGE
A108
EXIST
NATATORIUM
A110
EXIST POOL
MECH
A112
EXIST POOL
EQUIP
A114
EXIST LAUNDRY
A111
EXIST ELEC
A113
FOYER
A101
MECHANICAL
A102
?
?
M. SHOWERS
232
M. TOILETS
233
W. LOCKERS
221
EXIST POOL DECK
A109
11
1 1
1
TELECOM KEYNOTES:
1. ROUGH IN ONLY. BACKBOX AND CONDUIT TO CEILING SPACE
ABOVE.
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
4
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM PART
PLAN - UPPER
LEVEL SOUTH
TT-104 1/8" = 1'-0"1 TELECOM PART PLAN - UPPER LEVEL SOUTH
A
B
C
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
EXPOSED TO
MEZZANINE
STRUCTURE ABOVE
EXPOSED TO
STRUCTURE ABOVE
SOUND-
ISOLATING G.B.
SOFFITS @
FOLDING
PARTITIONS
EXPOSED TO
STRUCTURE
120
STAIR
E.T.S.
103
EMP ENTRY
PT02
142
COMMUNITY
KITCHEN
112
KITCHEN
E.T.S.
101
VEST
PT02
E.T.S.
102
LOUNGE
PT
104
WOMEN
E.T.S.
S10
EXIT STAIR
PT02
131
GYM
E.T.S.
132
GYM STORAGE
PT02
108
P&R
DIRECTOR
E.T.S.
143
STORAGE
PT01
110
MEN
114
CLASSROOM
E.T.S.
115
RECV & STOR
PT01
113
STOR
111
WOMEN
123
STRENGTH
105
MEN
106
GAMES
107
STAFF
E.T.S.
109
ELEC
PT01
121
JR GOLF
122
HITTING
E.T.S.
118
STORAGE
PT01
LC03
9' - 0"
LC03
9' - 0"
OPEN TO ABOVE
E.T.S.
E.T.S.
GB SOFFIT @
STRUCTURAL
STEP
LAY-IN CEILING
GRID SYSTEM
PAINT UNDERSIDE OF DECK
AND EXPOSED STRUCTURE
PT07
10' - 0"
LC05
9' - 0"
LC05
9' - 0"LC05
9' - 0"
LC05
9' - 0"
LC05
9' - 0"
PT07
10' - 0"
PT07
10' - 0"
LC05
9' - 0"
LC02
10' - 0"
PT03
9' - 10"
ETS
PT01
PT11
12' - 9"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC02
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
PT02
8' - 6"
LC02
11' - 0"
LC02
9' - 8"
LC02
11' - 0"
LC02
11' - 0"
LC02
9' - 0"
LC01
9' - 0"
PT11
9' - 6"
PT11
9' - 6"PT11
9' - 6"
PT11
9' - 6"
PT11
9' - 0"
PT03
10' - 8"
PT11
9' - 0"
PT03
10' - 8"
PT03
10' - 8"
ETS
?
ETS
?
ETS
?
ETS
?
ETS
?
ETS
?
ETS
?
LC02
9' - 0"
141
COMMUNITY
180
STOR.
E.T.S.
PT08
8' - 11"
2'-8"
2 4'-4 1/4"
4'-2"
1 3'-6 1/2"
19'-9 5/8"
2'-1 1/4"
3 1/4"
1'-11"
17'-8 3/8"
1'-8 1/4"
3 1/8"
2'-4 3/8"
19'-1 3/4"
10'-6 1/8"
4 7/8"
2'-8 5/8"
1'-4 1/4"
2'-4 3/8"
3 0 ' - 6 1 /4 "
1'-8"
2'-2 3/8"
12'-2"2'-2"1'-4"
PT04
8' - 0"
PT08
8' - 6"
5'-2"
7'-
3
1
/
8
"
18
'
-
1
0
7
/
8
"
2'-
3
1
/
8
"
1'-0 3/4"
4'-
0
3
/
8
"
5'-1 3/8"
5'-
4
1
/
4
"
26
'
-
2
"
4'-
0
1
/
8
"
1'-
8
"
8'-1 1/8"
3'-4 1/4"
14'-2"
3'-0 1/4"
14'-2"
16' - 9"
18' - 5"
2
1
'
-
9
3
/
4
"
7' - 11 3/4"
6'-
9
3
/
8
"
3'-5 5/8"
1'-
2
5
/
8
"
10'-6 7/8"
11
'
-
1
1
/
8
"
23'-6 1/2"20'-8 1/2"
9'-
7
1
/
2
"
12
'
-
3
5
/
8
"
1'-7 3/8"
6'-
4
1
/
8
"
SLOPE
TO MACH
STAIR
LC02
9' - 2"
PT04 ON STEEL
BEAMS EXPOSED
CEILING TYP.
PT02 ON EXPOSED
CEILING BETWEEN STEEL
BEAMS
PT02
PT02
8' - 6"
PT04
PT01
PT02
PT11 ON
UNDERSIDE OF
STAIR
ETS
?
PT02
PT02
PT02
PT07
10' - 0"
PT02
PT02
PT02
PT02
PT02
PT02
PAINT EXPOSRED
CEILING, HVAC, AND
STRUCTURE PT02 TYP.
GYP. BD. SOFFIT
PT07
ETS
?
PT02
PT02
ETS
PT01
E.T.S.
124
MP GROUP EX
PT03
PAINT EXPSED CEILING, HVAC,
AND STRUCTURE PT02 TYP.
PT11
14' - 1"
36'-0 1/2"PT02
LC02
SLOPED 3:12
9'-2" START
LC02
SLOPED 3:12
9'-2" START
LC02
SLOPED 3:12
9'-2" START
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
MEN
110
CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
STORAGE
118
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
5
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM OVERALL
RCP - LOWER LEVEL
TT-112
1/8" = 1'-0"1 TELECOM OVERALL RCP - LOWER LEVEL
A
B
C
J JJJJJJJJJ
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
/1 A113/1 A113
E.T.S.
202
LOBBY
PT03
202
LOBBY
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
TT-200
2
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
6
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM PART RCP
- UPPER LEVEL
NORTH
TT-113
1/8" = 1'-0"1 TELECOM PART RCP - UPPER LEVEL NORTH
J
J
J
/1 A113/1 A113
E.T.S.
253
POOL MECH
PT20
256
POOL OFFICE
221
W. LOCKERS
E.T.S.
205
INDOOR PLAY
PT19
A106
W. TEAM
LOCKERS
A109
EXIST POOL
DECK
222
W. SHOWERS
223
W. TOILETS
233
M. TOILETS
232
M. SHOWERS
E.T.S.
229
JAN
A111
EXIST
LAUNDRY
A112
EXIST POOL
MECH
A113
EXIST ELEC
A114
EXIST POOL
EQUIP
A115
EXIST CHEM
A110
EXIST
NATATORIUM
A108
POOL
STORAGE
A107
M. TEAM
LOCKER
E.T.S.
A102
MECHANICAL
E.T.S.
255
POOL STORAGE
PT20
E.T.S.
259
CIRC
206
OFFICE
207
KIDS T
288
KID WATCH
E.T.S.
254
ELEC
-
257
GUARD CHG
258
GUARDS
A105
STORAGE
PT20
10' - 0"
PT02
9' - 0"
LC03
9' - 0"
LC01
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
LC03
9' - 0"
231
M. LOCKERS
LC03
8' - 0"
LC03
7' - 10"
A103
M. LOCKERS
2
LC02
9' - 6"
9' - 0"
19
'
-
5
3
/
8
"
1'-
5
"
GYP./ PT11
8' - 6"GYP./ PT11
8' - 6"
LC01
9' - 0"
LC01
9' - 0"
PT15
8' - 6"
PT15
8' - 6"
9' - 0"
LC03
8' - 0"
LC03
8' - 0"
1
A104
VESTIBULE
LC03
8' - 4"
A109
EXIST POOL
DECK
LC03
7' - 10"
LC03
8' - 10"
A101
FOYER
A109A
POOL DECK
ENTRY
3 4 5 6 76.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13
E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205
W. TEAM
LOCKERS
A106
M. LOCKERS
231
FOYER
A101
EXIST POOL DECK
A109
W. SHOWERS
222
W. TOILETS
223
M. TOILETS
233
M. SHOWERS
232
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201
EXIST LAUNDRY
A111
EXIST POOL
MECH
A112
EXIST ELEC
A113EXIST POOL
EQUIP
A114
EXIST CHEM
A115
EXIST
NATATORIUM
A110
POOL STORAGE
A108
M. TEAM LOCKER
A107
MECHANICAL
A102
POOL STORAGE
255
CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARD CHG
257
GUARDS
258
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
8
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM PART RCP
- UPPER LEVEL
SOUTH
TT-114 1/8" = 1'-0"1 TELECOM PART RCP - UPPER LEVEL SOUTH
2
2
A4
AF
G
TT-200
3
SECURITY EQUIP.
A4
AF
G
REC ROOF
2' - 0"
UPPER LEVEL
0' - 0"
4 RU FIBER PATCH PANEL
FOR BACKBONE CABLING
2 RU CABLE MANAGEMENT PANEL (TYP.)
SPACE RESERVED FOR
NETWORK SWITCHES AND
SERVERS BY OTHERS
48 PORT ANGLED PATCH PANEL FOR
BUILDING OUTLETS
48 PORT ANGLED PATCH PANEL
FOR WIRELESS ACCESS POINTS
48 PORT ANGLED PATCH PANEL
FOR VIDEO SURVEILLANCE
(SECURITY)
12" VERTICAL WIRE MANAGEMENT
10" VERTICAL WIRE MANAGEMENT
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
4
:
5
9
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM
ENLARGED PLAN
TT-200
1/2" = 1'-0"1 ENLARGED PLAN - MDF ROOM
1/2" = 1'-0"2 ENLARGED PLAN RCP - MDF ROOM
1" = 1'-0"3 MDF RACK ELEVATION
LOWER LEVEL
UPPER LEVEL
LAN 276
MANHOLE
1
1
TELECOM BACKBONE CONDUIT KEYNOTES:
SERVICE ENTRANCE CONDUITS
(3) 4" CONDUITS WITH:
(3) 3" 3-CELL MAXCELL INNERDUCT IN EACH CONDUIT
REFER TO CIVIL FOR CONDUIT ROUTING
LOWER LEVEL
UPPER LEVEL
LAN 276
MANHOLE
1
1
TELECOM BACKBONE CABLING KEYNOTES:
ALL CABLES PLACED IN UNDERGROUND CONDUITS SHALL BE INDOOR/OUTDOOR RATED.
INCOMING SERVICES
(1) 24 STRAND SM FIBER
(1) 24 STRAND MM FIBER
(1) 100 PAIR COPPER
(1) COAX
REFER TO CIVIL FOR CONDUIT ROUTING
SHEET NOTES:
1. ALL PATHWAYS ARE DIAGRAMMATIC AND ARE SHOWN FOR REFERENCE ONLY.
2. COORDINATE ROUTING AND INSTALLATION OF TELECOM CONNECTIVITY WITH SITE CONDITIONS
ADHERING TO CONTRACT DOCUMENTS, INDUSTRY STANDARDS, AND BICSI BEST PRACTICES.
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
5
:
0
0
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
TELECOM RISERS
TT-300
1 1/2" = 1'-0"1 TELECOM BACKBONE CONDUIT RISER
1 1/2" = 1'-0"2 TELECOM BACKBONE CABLING RISER
BUILDING
GROUNDING
ELECTRODE SYSTEM
(BY OTHERS)
TO TYPICAL EQUIPMENT
TGB 1 (BY OTHERS)
LEVEL 1 BDF ROOM
EQUIPMENT RACKS LADDER RACK
PANELS
SERVING
TELECOM
ROOMS
ALL
TELECOMM
SLEEVES AND
RACEWAYS
TYPICAL EQUIPMENT
BONDED
TO ALL TGB'S AND TMGB
(TYPICAL FOR ALL FLOORS IN
CONTRACT)
LEVEL 2 TR
GROUNDING CONDUCTOR SIZING
LINEAR LENGTH m (ft) CONDUCTOR SIZE (AWG)
LESS THAN 4 (13) 6
4-6 (14-20) 4
6-8 (21-26) 3
8-10 (27-33) 2
10-13 (34-41) 1
13-16 (42-52) 1/0
16-20 (53-66) 2/0
GREATER THAN 20 (66) 3/0
CABLE TRAY
THIRD FLOOR TR TGB 2
TO TYPICAL
EQUIPMENT
TO FOURTH FLOOR TR
MINIMUM #6 AWG COPPER BONDING
CONDUCTOR IN GREEN INSULATED
JACKET
(TYPICAL FOR ALL - SEE TABLE)
BUILDING POWER
SYSTEM
MAIN GROUND BUS
BONDING
CONDUCTOR FOR
TELECOMMUNICATIO
NS
#3/0 AWG
TELECOMMUNICATIONS MAIN
GROUNDING
BUSBAR (TMGB) LOCATED IN BDF ROOM
TELECOMMUNICATIONS
BONDING
BACKBONE (TBB) #3/0 AWG
H-TAP, CADWELD, OR OTHER
NON-REVERSABLE SPLICE (TYPICAL)
#3/0 AWG TBB
3/0 AWG BARE COPPER
BONDING CONDUCTOR
(TYP.)
THIS CONNECTION IS NOT
REQUIRED
FOR SLEEVES OR RACEWAYS
BONDED TO THE TBB OR GE. SEE
NOTE 3.
CADWELD BUILDING STEEL
(IF
AVAILABLE)
GROUNDING NOTES:
1. ALL BUSBARS SHALL BE 2"X12"X1/4" (UON) PRE-
DRILLED TIN-PLATED COPPER. MOUNT ON WALL
WITH 2" STANDOFF INSULATORS AND
PLEXIGLASS.
2. ALL CABLE CONNECTIONS TO TGB'S ARE TWO
HOLE LONG BARREL COMPRESSION LUGS,
UNLESS OTHERWISE NOTED.
3. BONDING CONDUCTORS SHALL GENERALLY BE
RUN OPEN WITH PLASTIC SUPPORTS. WHERE
RUN IN STEEL CONDUITS LONGER THAN 36", BOND
CONDUIT TO TBB OR GE AT BOTH ENDS.
4. BONDING CONDUCTORS SHALL BE RUN
WITHOUT SPLICES WHEREVER POSSIBLE. ANY
SPLICES MUST BE MADE WITH NON-REVERSABLE
COMPRESSION CONNECTORS OR CADWELD.
5. BONDING CONDUCTORS SHALL BE COPPER
CONDUCTORS WITH GREEN INSULATION OR
DISTINCTIVE GREEN MARKING, UNLESS
OTHERWISE NOTED.
6. THE SIGNAL GROUNDING SYSTEM SHALL BE
TIED TO THE INCOMING BUILDING ELECTRICAL
SAFETY GROUND AT THE PRIMARY
TRANSFORMER NEUTRAL BOND, AND/OR AT THE
NEUTRAL BOND OF ANY SEPERATELY DERIVED
SOURCE IN ACCORDANCE WITH APPLICABLE
CODE. THE SYSTEM GROUND RESISTANCE SHALL
BE LESS THAN 5.0 OHMS. THIS SYSTEM SHALL BE
DESIGNED AND INSTALLED IN ACCORDANCE WITH
THE TIA/EIA ANSI-J-STD-607A, COMMERCIAL
BUILDING GROUNDING (EARTHING) AND BONDING
REQUIREMENTS FOR TELECOMMUNICATIONS.
3 "
1 "
2 "
T Y P .
A S R E Q U I R E D
1"
1 1/8"
2" HIGH RED STENCILED LETTERING
CLEAR 3/8" THICK PLEXIGLASS COVER
5/8"-11 x 1-1/2" CONT. THREADED ROD (TYP)
2-3/4" INSULATOR
9/16" (40) PLACES
5/8-11x1" H.H.C.S.
2-3/4"INSULATOR
7/16" DIA. (20) PLACES
2-3/4"INSULATOR
5/8" DIA.
5/8-11x1" H.H.C.S.
LOCKWASHER
5/8"DIA. (TYP.)
T B B
MIN 6"
MIN 12"
NOTE: CONTRACTOR TO INSTALL CONDUIT STUB WITH NO MORETHAN (2) 90° BENDS OTHERWISE SHOP DRAWINGS MUSTBE SUBMITTED AND APPROVED PRIOR TO INSTALLATION
LINEAR FOOTAGE OF TELECOMMUNICATIONS CABLING
BETWEEN CONDUIT STUB BUSHING AND APPROVED
HORIZONTAL CABLE SUPPORT SYSTEM NOT TO EXCEED
STUD WALL ASSEMBLY
FIRE STOP AS REQUIRED BY AHJ FOR MEMBRANE
PENETRATION WHEN CONDUIT STUB IS INSTALLED
WITHIN RATED WALLS
PLASTIC CONDUIT BUSHING
RATED FOR INSTALLATION
PLENUM SPACES
EMT CONDUIT, REFER TO
TELECOM SYMBOL
LEGEND FOR EXACT SIZE
MIN. 12" RADIUS CONDUIT BEND
LAY IN ACOUSTICAL TILE CEILING
OUTLET BACK BOX.
REFER TO TELECOM SYMBOL LEGEND FOR EXACT
SIZES. REFER TO ARCHITECTURAL DRAWINGS FOR
EXACT MOUNTING HEIGHT.
WRAP EXTERIOR OF BACK BOX WITH FIRE STOP
PADS AS REQUIRED BY AHJ WHEN BACK BOX IS
INSTALLED WITHIN RATED WALLS
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
5
:
0
0
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
NF
NF
10-17-2016
16003
TELECOM DETAILS
SHEET
TT-400
1/4" = 1'-0"1 Building Grounding System
1/4" = 1'-0"2 Ground Bar TBB
1/2" = 1'-0"3 Wall Outlet Stub Up 1
(3) 3" CELL
ASSEMBLY
WITH BLACK
TRACE
(3) 3" CELL
ASSEMBLY
WITH BLUE
TRACE
(3) 3" CELL
ASSEMBLY
WITH RED
TRACE
4" CONDUIT
NOTE:
1. PULLING TAPE NOT SHOWN
INTENTIONALLY
COLOR CODED PULL TAPE
3 INCH INNERDUCT CELLS
COLOR TRACE STITCHED
INTO THE ASSEMBLY
WOVEN FABRIC
INNERDUCT ASSEMBLY
1000 f
t
1000 ft 1
00
0
ft
30AMP 208V (L6-30R), WITH
TWIST-LOCK RECEPTACLE
POWER STRIP
CIRCUITS TO BE INSTALLED AT
THE FOOTER OF THE RACK IN
J-BOX ON THE WALL. CAP WIRES
IN J-BOX.
LADDER TYPE
CABLETRAY
7"
"B" 4" LOOP
"D"
"C"
FIG. "A"
"A" & "B"
"E"
"F"
CAT425A6
PART NO.
FIG. "A"
FIG NO.
9 1/2"
"A" 6" LOOP
13/16"
"F"
7 1/8"
"D"
5"
"C" "E"
1 3/8" 9/32"
"G" "H"
25/64"
NOTE: LOAD FOR EACH CAT 425A6 NOT TO EXCEED 100 lbs
MAXIMUM 250 UTP CABLES
LATCH WHERE STRAP
MAY BE RELEASED
NEED HAND ACCESS
TO THIS POINT
"H"
"G"
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
As indicated
10
/
3
1
/
2
0
1
6
1
1
:
5
5
:
0
1
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
TELECOM DETAILS
SHEET
TT-401
6" = 1'-0"1 Fabric Innerduct 4 in Cross-Section
6" = 1'-0"2 Fabric Innerduct
1/2" = 1'-0"3 4-Post Rack Ladder Rack Plugstrip ISO
6" = 1'-0"4 Cable Support Strap
1-GANG FACEPLATE
8-PIN MODULAR IDC JACKS,
REFER TO SECTION 27 15 43,
JACK COLOR TO MATCH
FACEPLATE U.O.N
LABELING WINDOW
NOTE:
COLORS TO BE
VERIFIED THROUGH
SUBMITTAL PROCESS
MINIMUM 4" SQUARE METAL BACK BOX
WITH WITH SINGLE GANG DEVICE RING
MINIMUM 1" CONDUIT FROM BACK BOX
TO ACCESSIBLE CEILING
SHEATH COLOR
BACK BOX:CONDUIT STUB:SYMBOL:
CABLE TYPEQUANTITY
CABLE DETAILS:
2 4-PAIR UTP CAT 6A CABLES CABLE NO. 1: BLUE
CABLE NO. 2: BLUE
2
(1) 8 PIN MODULAR JACKS
LABEL WITH PLASTIC SHIELD
PLENUM RATED OUTLET BOX
(1) BLANK MODULE
NOT APPLICABLENOT APPLICABLE
SHEATH COLOR
BACK BOX:CONDUIT STUB:SYMBOL:
CABLE TYPEQUANTITY
CABLE DETAILS:
1 4-PAIR UTP CAT 6A CABLES CABLE NO. 1: BLUE
NOTE:
REFER TO ABOVE CEILING GENERAL
DETAILS FOR INFORMATION ON
SLACK AND OUTLET POSITIONING
CAM
FLOOR BOX; COORDINATE BOX TYPE
AND INSTALLATION WITH ELECTRICAL
& AUDIOVISUAL CONTRACTORS
2-PORT FACEPLATES;
COORDINATE WITH FLOOR BOX.
NOT APPLICABLENOT APPLICABLE
SHEATH COLOR
BACK BOX:CONDUIT STUB:SYMBOL:
CABLE TYPEQUANTITY
CABLE DETAILS:
4 4-PAIR UTP CAT 6A CABLES CABLE NO. 1: BLUE
CABLE NO. 2: BLUE
CABLE NO. 3: BLUE
CABLE NO. 4: BLUE
8-PIN MODULAR IDC JACKS, REFER
TO SECTION 27 15 43.
4
(2) 8 PIN MODULAR JACKS
LABEL WITH PLASTIC SHIELD
PLENUM RATED OUTLET BOX
NOT APPLICABLENOT APPLICABLE
SHEATH COLOR
BACK BOX:CONDUIT STUB:SYMBOL:
CABLE TYPEQUANTITY
CABLE DETAILS:
2 4-PAIR UTP CAT 6A CABLES CABLE NO. 1: BLUE
CABLE NO. 2: BLUE
AP
NOTE:
REFER TO ABOVE CEILING GENERAL
DETAILS FOR INFORMATION ON
SLACK AND OUTLET POSITIONING
1-GANG FACEPLATE
8-PIN MODULAR IDC JACKS,
REFER TO SECTION 27 15 43,
JACK COLOR TO MATCH
FACEPLATE U.O.N
LABELING WINDOW
NOTE:
COLORS TO BE
VERIFIED THROUGH
SUBMITTAL PROCESS
MINIMUM 4" SQUARE METAL BACK BOX
WITH WITH SINGLE GANG DEVICE RING
MINIMUM 3/4" CONDUIT FROM BACK BOX
TO ACCESSIBLE CEILING
SHEATH COLOR
BACK BOX:CONDUIT STUB:SYMBOL:
CABLE TYPEQUANTITY
CABLE DETAILS:
1 4-PAIR UTP CAT 6A CABLES CABLE NO. 1: BLUE
1
BLANK MODULE
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
12" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
5
5
:
0
2
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
n
f
r
a
n
k
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
TELECOM DETAILS
SHEET
TT-402