HomeMy WebLinkAboutPLANS 660 Community Dr Community Center 2016-10-17S
J
J
J
SC
J
DRAWINGLIST:
AFC AT FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFP ABOVE FINISHED PLATFORM OR RAISED FLOOR
AS ABOVE SLAB
ATS ABOVE TABLE SURFACE
AV AUDIOVISUAL
CAT-5E TIA/EIA CATEGORY 5E RATED
CAT-6 TIA/EIA CATEGORY 6 RATED
CLG CEILING
EMT
FPD FLAT PANEL DISPLAY
GND GROUND
IDA INSIDE DIAMETER
IDF INTERMEDIATE DISTRIBUTION FRAME
LAN LOCAL AREA NETWORK
MAX MAXIMUM
MDF MAIN DISTRIBUTION FRAME
MIN MINIMUM
MM MULTIMODE
MTD MOUNTED
MTER MAIN TELECOMMUNICATIONS EQUIPMENT ROOM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OFE OWNER FURNISHED EQUIPMENT
OSP OUTSIDE PLANT
PB PULLBOX
SM SINGLE MODE
ST STRAND
STP SHIELDED TWISTED PAIR
TBD TO BE DETERMINED
TEMP TEMPORARY
TGB TELECOMMUNICATIONS GROUND BAR
TR TELECOMMUNICATIONS ROOM
TSER TELECOMMUNICATIONS SERVICE ENTRANCE ROOM
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
VIF VERIFY IN FIELD
VOIP VOICE OVER INTERNET PROTOCOL
WAN WIDE AREA NETWORK
WAP WIRELESS ACCESS POINT
WP WATERPROOF
WW WIREWAY
1.
2.
3.
4.
4.1.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
SCOPE OF WORK PROVIDE FURNISH INSTALL
IN-WALL BLOCKING SUPPORT FOR AV MOUNTS GC GC
MOTORIZED PROJECTION SCREENS GC GC
PROJECTION GLASS GC GC
WALL AND CEILING SPEAKER CUTOUTS GC
FURNITURE CUTOUTS FOR AV EQUIPMENT (UNLESS
PROVIDED BY FURNITURE PROVIDER)GC
MOTORIZED PROJECTION LIFTS AV GC
KINDORF AND/OR BLACK IRON AS REQUIRED FOR CEILING
MOUNTED AV DEVICES GC GC
CABLE CONTAINMENT INCLUDING:EC EC
- CONDUIT WITH MEASURED PULLSTRINGS EC EC
- CABLETRAY, LADDERTRAY, AND WIREWAYS EC EC
- FLOORBOXES EC EC
- JUNCTION BOXES, PULL BOXES, AND BACKBOXES EC EC
POWER OUTLETS EC EC
DEDICATED DISTRIBUTION PANELS, LOAD CENTERS, AND
POWER ISOLATION TRANSFORMERS EC EC
AV CABLING (LOW VOLTAGE)AV AV
AV TERMINATIONS AV AV
CUSTOM ENGRAVED AV COVER PLATES AV AV
J-HOOKS AND OTHER SUPPORTS REQUIRED
FOR OPEN-RUN AV CABLING AV AV
AV DEVICE WALL MOUNTS AV AV
AV DEVICES (AS DESCRIBED IN THE AV BID DOCUMENTS) AV AV
VOICE/DATA NETWORK CABLING (FIBER AND TWISTED PAIR) ST ST
VOICE/DATA COVER PLATES ST ST
CATV CABLING ST ST
LIGHTING & SHADE CONTROL INTERFACE EC EC
MINIMUM ACCEPTABLE DISTANCE BETWEEN PARALLEL AV AND POWER CONDUITS
AV CONDUIT POWER
CONDUIT
COMBINED AMPACITY OF ALL PHASE CONDUCTORS
IN POWER CONDUIT
UNDER 60A 60A 120A 240A 400A
EMT EMT
2 FT. 3 FT. 4 FT. NA NA
EMT RIGID STEEL 4 IN. 8 IN. 1 FT. 2 FT. 4 FT.
RIGID STEEL RIGID STEEL
1 IN. 2 IN. 4 IN. 8 IN. 16 IN.
REFER TO AV DETAIL SHEETS FOR ADDITIONAL SCOPE DELINEATION
AND INFORMATION
DEFINITION OF TERMS
LEGEND FOR SCOPE OF WORK BETWEEN TRADES:
GC = GENERAL CONTRACTOR
EC = ELECTRICAL CONTRACTOR
AV = AUDIOVISUAL CONTRACTOR
O = OWNER
ST = STRUCTURED CABLING, OR TELECOMMUNICATIONS CONTRACTOR
ALL AV CABLING THAT IS RUN OPEN-WIRE SHALL BE SUPPORTED
FROM J-HOOKS NO GREATER THAN 3 FEET APART. NO CABLE IS TO
BE UNSUPPORTED OR LAID OVER CEILING TILES, BLACK IRON, OR
OTHER CEILING MEMBERS.
THE METHOD OF INSTALLATION OF BOXES IN WALLS, AND THE
METHOD OF PASSAGE OF CONDUITS AND WIREWAYS THROUGH
ACOUSTICALLY SENSITIVE WALLS SHALL BE COORDINATED WITH
THE ACOUSTICAL CONSULTANT.
INSTALL FIRESTOP TO ALL SLAB AND WALL PENETRATIONS
PROVIDED FOR THE INSTALLATION OF CABLE AND CONDUIT AS
REQUIRED TO MAINTAIN FIRE RATING OF SLAB OR WALL. REVIEW
ARCHITECT'S PLANS FOR PARTITION TYPES.
ALL POWER, WIREWAYS, AND JUNCTION BOXES ARE TO BE
REVIEWED BY ELECTRICAL ENGINEER FOR CODE AND SAFETY
COMPLIANCE.
ALL OVERHEAD RIGGING REQUIREMENTS ARE TO BE REVIEWED AND
STAMPED FOR APPROVAL BY LICENSED STRUCTURAL ENGINEER FOR
CODE AND SAFETY COMPLIANCE.
POWER BREAKER AND DISTRIBUTION PANELS ARE SIZED AND
SPECIFIED BY THE ELECTRICAL ENGINEER.
ALL CABLE TRAY THAT IS SURFACE-MOUNTED ON SLAB BELOW
RAISED FLOOR OR ABOVE EQUIPMENT RACKS SHALL BE SECURELY
FASTENED AND LEFT OPEN FOR CABLE ACCESS.
POWER FOR AV AND RELATED SYSTEMS SHALL USE AN EIA/TIA 607
COMPLIANT GROUNDING SYSTEM, DESIGNED BY THE ELECTRICAL
ENGINEER. REFER TO AV DETAIL SHEETS FOR ADDITIONAL
GROUNDING REQUIREMENTS IF APPLICABLE.
ALL AV-RELATED EMPTY CONDUIT SHALL BE REAMED, CLEANED,
CAPPED (WHERE APPROPRIATE), TAGGED, AND FURNISHED WITH
PULL WIRES.
WHERE EXACT DIMENSIONS ARE NOT INDICATED, THE SCALE OF THIS
DRAWING IS SUFFICIENTLY ACCURATE FOR DETERMINING THE
LOCATION OF EQUIPMENT, JUNCTION BOXES, OUTLET BOXES,
WIREWAYS, PANELS, ETC. WHERE EXACT DIMENSIONS ARE
INDICATED, THE REFERENCE SURFACE SHALL BE THE FINAL
FINISHED SURFACE INCLUDING ANY ACOUSTICAL TREATMENT.
ROOM DIMENSIONS ON THE DRAWINGS HAVE BEEN TAKEN FROM
PRELIMINARY ARCHITECTURAL DRAWINGS. ALL DIMENSIONS MUST
BE VERIFIED AND ANY DEVIATIONS CAUSING CHANGES MUST BE
COORDINATED WITH SHEN MILSOM & WILKE, LLC.
NOTIFY OWNER'S REPRESENTATIVES OF ANY DISCREPANCIES
BETWEEN THE EXISTING CONDITIONS AND THE AV DRAWINGS.
OBTAIN CLARIFICATION BEFORE PROCEEDING WITH WORK.
ALL AV DEVICES SHALL BE SECURELY MOUNTED PLUMB AND
STRAIGHT TO WALLS, FLOORS, OR RACKS PER THE
MANUFACTURER'S RECOMMENDED MOUNTING PRACTICE.
THE METHOD OF INSTALLATION OF BOXES IN WALLS, AND THE
METHOD OF PASSAGE OF CONDUIT AND WIREWAYS THROUGH
ACOUSTICALLY SENSITIVE WALLS, SHALL BE COORDINATED WITH
THE ACOUSTICAL CONSULTANT OR ARCHITECT.
THERE SHALL BE A MINIMUM OF ONE PULL BOX FOR EVERY 100' OF
STRAIGHT EMPTY AV-RELATED CONDUIT AND ONE PULL BOX WHERE
THERE ARE MORE THAN TWO 90° BENDS OR LESSER BENDS
TOTALING 180° IN A CONDUIT RUN.
MAINTAIN MINIMUM BEND RADIUS OF 10X OD FOR ALL AV-RELATED
CONDUITS.
LIGHTING DESIGNER TO PROVIDE LIGHTING ON A SEPARATE DIMMING
ZONE AT THE SCREEN/DISPLAY DEVICE TO ENSURE GOOD CONTRAST
AND IMAGE SHARPNESS.
AV CONTRACTOR SHALL RESTORE CEILINGS, WALLS AND ANY OTHER
SURFACES AFFECTED BY THEIR WORK PRIOR TO COMPLETION OF
WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION.
REFER TO AV ELECTRICAL PLANS AND/OR RISER DIAGRAMS FOR
EMPTY CONDUIT SIZING.
ALL POWER CIRCUITS INDICATED IN THIS DRAWING SET TO BE
PROVIDED BY DEDICATED BREAKER PANEL(S). NO NON-AV CIRCUITS
TO BE FED FROM DEDICATED AV BREAKER PANEL(S).
POWER AND DATA REQUIREMENTS SHOWN FOR REFERENCE ONLY
AND ARE NOT FOR CONSTRUCTION. COORDINATE WITH ELECTRICAL
ENGINEER, ARCHITECT AND TELECOM DESIGNER DRAWINGS FOR
LOCATION OF ALL OUTLETS IN THIS DRAWING SET.
WHERE POWER CIRCUITS ARE SHOWN TERMINATING IN JUNCTION
BOXES WITHOUT RECEPTACLES, THE WIRES SHALL BE TAPED AND
THE BOXES COVERED. THESE CIRCUITS WILL BE CONNECTED BY
OTHERS DURING INSTALLATION OF THE AV SYSTEMS EQUIPMENT.
EMPTY CONDUIT RUNS ON THESE DRAWINGS SHOW ONLY
INTERCONNECTION BETWEEN TERMINATION POINTS. THE EXACT
PATH OF CONDUIT IS TO BE DETERMINED BY THE COORDINATE
PATHWAYS FOR ALL AV RELATED DEVICES WITH ARCHITECTURAL
AND ELECTRICAL PLANS.
HIGH LEVEL/HIGH CURRENT FEEDS (SUCH AS FOR POWER
DISTRIBUTION PANELS, LIGHTING, AND BRANCH CIRCUITS,) ARE NOT
TO BE RUN PARALLEL WITH AUDIO/VIDEO CONDUITS OR CABLING. IF
HIGH LEVEL/HIGH CURRENT FEEDS MUST RUN PARALLEL TO
AUDIO/VIDEO CONDUITS OR CABLING, MINIMUM SEPARATION MUST
BE MAINTAINED ACCORDING TO THE FOLLOWING TABLE. "NA"
INDICATES THAT THE USE SHOULD BE AVOIDED. SPACINGS ASSUME
THAT POWER CONDUCTORS WILL NOT BE TWISTED PAIRS. CLOSER
SPACINGS CAN BE USED IF POWER CONDUCTORS ARE TWISTED
PAIRS.
NO LARGE POWER TRANSFORMERS OR MOTORS SHOULD BE
LOCATED WITHIN 50 FEET OF AV EQUIPMENT SPACES.
FURNISH - TO PURCHASE AND DELIVER TO THE PROJECT SITE
COMPLETE WITH EVERY NECESSARY APPURTENANCE AND
SUPPORT. PURCHASING SHALL INCLUDE PAYMENT OF ALL SALES
TAXES AND OTHER SURCHARGES AS MAY BE REQUIRED TO ASSURE
THAT PURCHASED ITEMS ARE FREE OF ALL LIENS. CLAIMS, OR
ENCUMBRANCES.
INSTALL - TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND
PERFORM EVERY OPERATION NECESSARY TO ESTABLISH SECURE
MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN
THE PROJECT, ALL AS PART OF THE WORK.
PROVIDE - TO FURNISH AND INSTALL
ELECTRICAL FLOOR MOUNTED SYMBOLS: ELECTRICAL CEILING MOUNTED SYMBOLS: NOTES:ABBREVIATIONS:
ELECTRICAL WALL MOUNTED SYMBOLS:
SCOPE OF WORK BETWEEN TRADES:
EC
ELECTRICAL METALLIC TUBING (WITH PULL STRING)
EMPTY CONDUIT
22.
JUNCTION BOX, 6" x 6" x 4" DEEP, UON, WITH COVER PLATE FOR AV
RECEPTACLES. FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO
SLAB BELOW RAISED FLOOR.
CUSTOM FLOOR BOX WITH DIVIDED COMPARTMENTS FOR AV, DATA AND POWER.
FLUSH MOUNT IN FINISHED FLOOR WITH HINGED SCRUB WATER RATED COVER
PLATE AND CARPET FLANGE (VERIFY FINISH PLATE COLOR WITH ARCHITECT). FSR
FLOOR BOX MODEL FL-500P (4" DEEP), UON. REFER TO POWER AND DATA SYMBOL
DESCRIPTION FOR RELATED REQUIREMENTS.
(* = NUMBER OF POWER CIRCUITS)
(# = NUMBER OF DATA DROPS)
JUNCTION BOX, 2.5" DEEP, FOR AV RECEPTACLES. SINGLE GANG, UON. MOUNT FLUSH
WITH FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT,
UON.
(* = NUMBER OF GANGS)
CUSTOM FLAT PANEL DISPLAY JUNCTION BOX WITH SEPARATE COMPARTMENTS
FOR AV, DATA AND POWER. FSR INC. WALL BOX MODEL PWB-270 (4.0" DEEP). MOUNT
FLUSH WITH FINISHED WALL TREATMENT AT 58" AFF, UON. REFER TO POWER AND
DATA SYMBOL DESCRIPTION FOR RELATED REQUIREMENTS.
JUNCTION BOX, 2.5" DEEP, FOR AV RECEPTACLES SINGLE GANG, UON. FLUSH
MOUNTED IN FINISHED CEILING.
(* = NUMBER OF GANGS)
JUNCTION BOX, 2.5" DEEP, PROVIDE DOUBLE-GANG BOX, UON, FOR AV
RECEPTACLES. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.
(* = NUMBER OF GANGS)
SCREW COVER BOX FOR AV SIGNAL CABLE AND CONDUIT TERMINATION. SIZED BY
ELECTRICAL ENGINEER. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.
FP
FB
12" x 4", UON, CABLE TRAY. REFER TO AV NOTES FOR ADDITIONAL
INFORMATION.
LVC
LOW VOLTAGE CONTROLLER FOR PROJECTION SCREEN OR SHADE CONTROL.
SUPPLIED WITH SCREEN. SURFACE MOUNTED TO SLAB ABOVE FINISHED
CEILING. ACCESS PANEL TO CONTROLLER MUST BE PROVIDED FOR
MAINTENANCE.
ST CONDUIT STUB-UP INTO FURNITURE.
*
POWER RECEPTACLE, DUPLEX, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW
RAISED FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW RAISED
FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
*
P
JUNCTION BOX FOR POWER, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT BY THE
ELECTRICAL ENGINEER. FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE
MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
DATA OUTLET WITH TWO (2) DATA DROPS, UON. FLUSH MOUNTED IN FINISHED FLOOR
OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
(* = NUMBER OF DATA DROPS)
SC
W2
W1
SCREW COVER BOX FOR AV SIGNAL CABLE AND CONDUIT TERMINATION. SIZED
BY ELECTRICAL ENGINEER. MOUNT FLUSH WITH FINISHED WALL TREATMENT AT
STANDARD BASE OUTLET HEIGHT, UON.
WALL BOX, 6" x 6" x 4" DEEP, FOR AV RECEPTACLES. MOUNT FLUSH WITH
FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON.
WALL BOX, 12" x 12" x 4" DEEP, FOR AV RECEPTACLES. MOUNT FLUSH WITH
FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON.
R/L
WALL SWITCH FOR RAISE/LOWER OF PROJECTION SCREEN AND/OR FOR VIDEO
PROJECTOR LIFT. MOUNT AT STANDARD SWITCH HEIGHT, UON.
*
POWER RECEPTACLE, DUPLEX, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV
NOTES FOR ADDITIONAL INFORMATION.
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT. MOUNT
AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, 208 VAC, SINGLE DEDICATED 30 AMP CIRCUIT. MOUNT AT
BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
P
JUNCTION BOX FOR POWER, 120 VAC, 20 AMP, SIZED BY THE ELECTRICAL
ENGINEER. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON.
REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED CIRCUITS)
*
CP
RS
AN
DATA OUTLET WITH TWO (2) DATA DROPS, UON. MOUNT AT BUILDING STANDARD BASE
ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DATA DROPS)
DATA OUTLET FOR AV CONTROL PANEL. PROVIDE TRIPLE-GANG BOX WITH DOUBLE
GANG REDUCTION RING AND SINGLE POE DATA DROP. MOUNT AT 48" AFF, UON. REFER
TO AV NOTES FOR ADDITIONAL INFORMATION.
DATA OUTLET FOR ROOM SCHEDULING PANEL. PROVIDE DOUBLE-GANG BOX WITH
SINGLE-GANG REDUCTION RING AND SINGLE POE DATA DROP. MOUNT AT 48" AFF,
UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
DATA OUTLET FOR AUDIO NETWORK. PROVIDE TWO (2) DATA DROPS WITH NEUTRIK
ETHERCON CHASSIS CONNECTORS. MOUNT AT BUILDING STANDARD BASE
ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
LS
TV *
RS232 INTERFACE FOR LIGHTING AND SHADES. MOUNT AT BUILDING STANDARD BASE
OUTLET HEIGHT, UON.
CATV OUTLET WITH A SINGLE RF DROP. MOUNT AT BUILDING STANDARD BASE
OUTLET HEIGHT, UON.
(* = NUMBER OF CATV DROPS)
*
*
POWER RECEPTACLE, DUPLEX, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
FLUSH MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL
INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT. FLUSH
MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL
INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, 208 VAC, SINGLE DEDICATED 30 AMP CIRCUIT. FLUSH
MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL
INFORMATION.
*
P
*
POWER RECEPTACLE, DUPLEX, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.
SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR
ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
JUNCTION BOX FOR POWER, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT, SIZED
BY THE ELECTRICAL ENGINEER. SURFACE MOUNTED TO SLAB ABOVE FINISHED
CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DEDICATED POWER CIRCUITS)
*
*
DATA OUTLET WITH TWO (2) DATA DROPS, UON. FLUSH MOUNTED IN FINISHED
CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DATA DROPS)
DATA OUTLET WITH TWO (2) DATA DROPS, UON. SURFACE MOUNTED TO SLAB
ABOVE FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
(* = NUMBER OF DATA DROPS)
S1
ZONE *
LS
TV
*
S2
ZONE *
RS232 INTERFACE FOR LIGHTING AND SHADES. SURFACE MOUNTED TO SLAB
ABOVE FINISHED CEILING.
CATV OUTLET WITH A SINGLE RF DROP. SURFACE MOUNTED TO SLAB ABOVE
FINISHED CEILING.
(* = NUMBER OF CATV DROPS)
SPEAKER LOCATION AND ZONE IDENTIFICATION. SHOWN FOR COORDINATION
PURPOSES ONLY.
(* = SPEAKER ZONE)
CUSTOM SPEAKER BACK BOX. FLUSH MOUNTED IN FINISHED CEILING.
MANUFACTURER BACK BOX MODEL MODEL# (X.X" DEEP). SPEAKER DRIVER TO
BE INSTALLED AT A LATER DATE BY AV CONTRACTOR.
(* = SPEAKER ZONE)
23.
*#
*
*
*
*
*
*
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
12" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
3
4
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
COVER SHEET
TA-000
NUMBER NAME
TA-000 AUDIOVISUAL COVER SHEET
TA-102 AUDIOVISUAL FACILITY OVERALL PLAN -
LOWER LEVEL
TA-103 AUDIOVISUAL FACILITY PART PLAN - UPPER
LEVEL NORTH
TA-104 AUDIOVISUAL FACILITY PART PLAN - UPPER
LEVEL SOUTH
TA-112 AUDIOVISUAL FACILITY OVERALL RCP -
LOWER LEVEL
TA-113 AUDIOVISUAL FACILITY PART RCP - UPPER
LEVEL NORTH
TA-114 AUDIOVISUAL FACILITY PART RCP - UPPER
LEVEL SOUTH
TA-202 AUDIOVISUAL ELETRICAL OVERALL PLAN -
LOWER LEVEL
TA-203 AUDIOVISUAL ELETRICAL PART PLAN -
UPPER LEVEL NORTH
TA-204 AUDIOVISUAL ELETRICAL PART PLAN -
UPPER LEVEL SOUTH
TA-212 AUDIOVISUAL ELETRICAL OVERALL RCP -
LOWER LEVEL
TA-213 AUDIOVISUAL ELECTRICAL PART RCP -
UPPER LEVEL NORTH
TA-214 AUDIOVISUAL ELECTRICAL PART RCP -
UPPER LEVEL SOUTH
DN
A
B
C
DN
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
MEN
110
CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
STORAGE
118
V131
V115
V103
V115
V153
V131
V131
V119
V119
V290
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
3
7
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY OVERALL
PLAN - LOWER
LEVEL
TA-102
1/8" = 1'-0"1 AUDIOVISUAL FACILITY OVERALL PLAN - LOWER LEVEL
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V103 55" WALL MOUNTED FLAT PANEL DISPLAY
V115 AV CONNECTION PANEL
V119 WALL MOUNTED MANUAL PROJECTION SCREEN
V131 AV EQUIPMENT RACK, SMALL
V151 WALL MOUNTED AV CONTROL PANEL, 5"
V153 WALL MOUNTED AV CONTROL PANEL, 10"
V290 POLE MOUNTED VIDEO PROJECTOR
A
B
C
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
?
?
PARTY
211
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
VESTIBULE
201LOBBY
202
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
?
?
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
?
?
V151
V131
V131
V103
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
4
0
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY PART PLAN
- UPPER LEVEL
NORTH
TA-103 1/8" = 1'-0"1 AUDIOVISUAL FACILITY PART PLAN - UPPER LEVEL NORTH
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V103 55" WALL MOUNTED FLAT PANEL DISPLAY
V131 AV EQUIPMENT RACK, SMALL
V151 WALL MOUNTED AV CONTROL PANEL, 5"
3 4 5 6 76.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205M. LOCKERS
231
W. TOILETS
223
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201LOBBY
202
?
?
POOL STORAGE
255 CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARDS
258
?
?
?
?
?
?
M. TEAM LOCKER
A107
W. TEAM
LOCKERS
A106
POOL STORAGE
A108
EXIST
NATATORIUM
A110
EXIST POOL
MECH
A112
EXIST POOL
EQUIP
A114
EXIST LAUNDRY
A111
EXIST ELEC
A113
FOYER
A101
MECHANICAL
A102
?
?
M. SHOWERS
232
M. TOILETS
233
W. LOCKERS
221
EXIST POOL DECK
A109
V103
NOTE:
PROJECTABLE
WALL SURFACE
V131
V131
RELOCATE
EXISTING HEAD
END EQUIPMENT
TO POOL
STORAGE A108
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
4
3
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY PART PLAN
- UPPER LEVEL
SOUTH
TA-104 1/8" = 1'-0"1 AUDIOVISUAL FACILITY PART PLAN - UPPER LEVEL SOUTH
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V103 55" WALL MOUNTED FLAT PANEL DISPLAY
V131 AV EQUIPMENT RACK, SMALL
A
B
C
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
MEN
110 CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
STORAGE
118
V240
V240
V240
V240
V240
V240
V240
V240 V240 V240
V241V241
V240V240 V240
V241V241
V240 V240V240
V290
V202
V119
V119
V240
V240
V240
V240 V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V240
V290
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
4
5
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY OVERALL
RCP - LOWER LEVEL
TA-112
1/8" = 1'-0"1 AUDIOVISUAL FACILITY OVERALL RCP - LOWER LEVEL
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V119 WALL MOUNTED MANUAL PROJECTION SCREEN
V202 46" CEILING POLE MOUNTED FPD
V240 RECESSED CEILING LOUDSPEAKER (TYPE 1)
V241 RECESSED CEILING LOUDSPEAKER (TYPE 2)
V242 CEILING PENDANT SPEAKER
V290 POLE MOUNTED VIDEO PROJECTOR
A
B
C
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
A5
AE
AF
AG
AH
H
G
L
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
VESTIBULE
201
LOBBY
202
V202
V202
V202
V202
V202
V202
V242V242V242
V242V242V242
V242 V242V242
V240
V240
V240
V240
V240
V240
V240
V240 V240
V240 V240
V240
V240
V240
V240
V240 V240
V242V242V242
V241
V240
V240
V240
V240
V240
V240
V241
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
4
8
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY PART RCP -
UPPER LEVEL
NORTH
TA-113
1/8" = 1'-0"1 AUDIOVISUAL FACILITY PART RCP - UPPER LEVEL NORTH
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V202 46" CEILING POLE MOUNTED FPD
V240 RECESSED CEILING LOUDSPEAKER (TYPE 1)
V241 RECESSED CEILING LOUDSPEAKER (TYPE 2)
V242 CEILING PENDANT SPEAKER
3 4 5 6 76.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
INDOOR PLAY
205
W. TEAM
LOCKERS
A106
M. LOCKERS
231
FOYER
A101
EXIST POOL DECK
A109
W. SHOWERS
222
W. TOILETS
223
M. TOILETS
233
M. SHOWERS
232
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201
EXIST LAUNDRY
A111
EXIST POOL
MECH
A112
EXIST ELEC
A113EXIST POOL
EQUIP
A114
EXIST CHEM
A115
EXIST
NATATORIUM
A110
POOL STORAGE
A108
M. TEAM LOCKER
A107
MECHANICAL
A102
POOL STORAGE
255
CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARD CHG
257
GUARDS
258
LOBBY
202
V242
V242 V242
V242 V242
V242
V240
V240
V240
V240 V240
V240
V240
V240
V240
V240
V240V240
V240
V240
V240
V240
V240
V240
V240
V240
V242 V242
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
5
4
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
FACILITY PART RCP -
UPPER LEVEL
SOUTH
TA-114 1/8" = 1'-0"1 AUDIOVISUAL FACILITY PART RCP - UPPER LEVEL SOUTH
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
V240 RECESSED CEILING LOUDSPEAKER (TYPE 1)
V242 CEILING PENDANT SPEAKER
DN
A
B
C
DN
60"
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
MEN
110 CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
STORAGE
118
V301
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
5
6
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELETRICAL
OVERALL PLAN -
LOWER LEVEL
TA-202
1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL OVERALL PLAN - LOWER LEVEL
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION
V301 BACK BOX FOR FPD
A
B
C
60"
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
?
?
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
V301
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
1
:
5
8
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELETRICAL PART
PLAN - UPPER
LEVEL NORTH
TA-203
1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL PART PLAN - UPPER LEVEL NORTH
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION
V301 BACK BOX FOR FPD
60"
3 4 5 6 76.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205M. LOCKERS
231
W. TOILETS
223
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201LOBBY
202
?
?
POOL STORAGE
255 CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARDS
258
?
?
?
?
?
?
M. TEAM LOCKER
A107
W. TEAM
LOCKERS
A106
POOL STORAGE
A108
EXIST
NATATORIUM
A110
EXIST POOL
MECH
A112
EXIST POOL
EQUIP
A114
EXIST LAUNDRY
A111
EXIST ELEC
A113
FOYER
A101
MECHANICAL
A102
?
?
M. SHOWERS
232
M. TOILETS
233
W. LOCKERS
221
EXIST POOL DECK
A109
V301
V320
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
2
:
0
1
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELETRICAL PART
PLAN - UPPER
LEVEL SOUTH
TA-204 1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL PART PLAN - UPPER LEVEL SOUTH
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION
V301 BACK BOX FOR FPD
V320 AV FLOOR BOX
A
B
C
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
AB
AA
A5
AC
AD
AE
AF
AG
AH
H
G
L
MP GROUP EX
124
STAIR
120
?
?
ELEV
117
EMP ENTRY
103
COMMUNITY
KITCHEN
142
KITCHEN
112
VEST
101
LOUNGE
102
WOMEN
104
COMMUNITY
141
EXIT STAIR
S10
GYM
131
GYM STORAGE
132
P&R DIRECTOR
108
STORAGE
143
MEN
110
CLASSROOM
114
RECV & STOR
115
STOR
113
WOMEN
111
STRENGTH
123
MEN
105
GAMES
106
STAFF
107
ELEC
109
?
?
JR GOLF
121
HITTING
122
STORAGE
118
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
2
:
0
3
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELETRICAL
OVERALL RCP -
LOWER LEVEL
TA-212
1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL OVERALL RCP - LOWER LEVEL
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION
A
B
C
60"
3 4 5 6 7
A1
A
B
C
D
E
F
A2
A3
A4
A5
AE
AF
AG
AH
H
G
M/P GROUP EX
262
ST.
263
EXIT STAIR
S10
CARDIO
261
?
?
MEN
203
WOMEN
204
ADMIN
271
DESK STAFF
272
EXEC DIR
281
ASST
279
WATER & FIRE
ENTRY
273
IT
274
HR
283
FACILITY DIR
285
FINANCE
287
TEMP
284
COPY
278
LAN
276
MARKET
277
CONFERENCE
275
ELEC
282
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
2
:
0
5
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELECTRICAL PART
RCP - UPPER LEVEL
NORTH
TA-213
1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL PART RCP - UPPER LEVEL NORTH
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION
3 4 5 6 76.9 8 95.4
M
L
M.6
N
P
Q
EH
NJ
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13
E14
EG
EF
EE
ED
EC
EB
EA
1 2
?
?
POOL MECH
253
POOL OFFICE
256
W. LOCKERS
221
FAM CHANGING
212
PARTY
211
INDOOR PLAY
205
W. TEAM
LOCKERS
A106
M. LOCKERS
231
FOYER
A101
EXIST POOL DECK
A109
W. SHOWERS
222
W. TOILETS
223
M. TOILETS
233
M. SHOWERS
232
JAN
229
ACR1
213
ACR2
214
CHG
215
ACR3
216
VESTIBULE
201
EXIST LAUNDRY
A111
EXIST POOL
MECH
A112
EXIST ELEC
A113EXIST POOL
EQUIP
A114
EXIST CHEM
A115
EXIST
NATATORIUM
A110
POOL STORAGE
A108
M. TEAM LOCKER
A107
MECHANICAL
A102
POOL STORAGE
255
CIRC
259
OFFICE
206
KIDS T
207
KID WATCH
288
ELEC
254
GUARD CHG
257
GUARDS
258
?
?
LOBBY
202
?
?
?
?
?
?
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
5.
4.
3.
2.
1.
7.
8.
9.
10.
11.
12.
10-31-16 PERMIT SET
1/8" = 1'-0"
10
/
3
1
/
2
0
1
6
1
1
:
3
2
:
1
0
A
M
C:
\
S
M
W
\
R
e
v
i
t
\
S
M
W
_
1
6
1
1
6
_
T
_
E
V
C
C
_
R
1
6
_
s
m
o
e
d
e
.
r
v
t
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-17-2016
16003
AUDIOVISUAL
ELECTRICAL PART
RCP - UPPER LEVEL
SOUTH
TA-214 1/8" = 1'-0"1 AUDIOVISUAL ELECTRICAL PART RCP - UPPER LEVEL SOUTH
AUDIOVISUAL ELECTRICAL KEYNOTE LEGEND
NUMBER DESCRIPTION