Loading...
HomeMy WebLinkAboutPLANS 660 Community Dr Electrical 2016-10-31OS S/DS S FAA S V M 6'-8" 5'-4" 6'-0" TO CENTER (SEE NOTE 6) 1'-6" 3'-8" TO BOTTOM OF DEVICE (SEE NOTE 4) TOP OF CABINET CENTER OF CABINET TYPICAL 9'-0" CEILING TYPICAL 8'-0" CEILING 8'-0" 7'-4" TO CENTER TO BOTTOM 5'-0" TO CENTER AC AC AC AC POWER PANEL, FIRE ALARM PANEL, OR MASTER CLOCK 1. WHERE MULTIPLE LINE VOLTAGE DEVICES ARE SHOWN ADJACENT TO EACH OTHER, THEY ARE ALL TO SHARE THE SAME JUNCTION BOX, UP TO FOUR GANGS. 2. WHERE MORE THAN FOUR DEVICES ARE SHOWN ADJACENT TO EACH OTHER, DEVICES ARE TO STACK VERTICALLY ABOVE ONE ANOTHER IN TWO ROWS IN AS SMALL OF GANG BOXES AS POSSIBLE. I.E. SIX DEVICES WILL USE TWO THREE GANG BOXES, FIVE DEVICES WILL USE ONE THREE GANG AND ONE TWO GANG BOX. 3. SEPARATELY GANGED DEVICES ARE NOT ALLOWED TO BE INSTALLED ADJACENT TO ONE ANOTHER HORIZONTALLY WITHIN THE SAME STUD BAY. 4. AUDIBLE/VISUAL FIRE ALARM DEVICES SHOWN ARE TO BE MOUNTED AT 90" OR 6" BELOW CEILING, WHICHEVER IS LOWER. ADA STROBES TO BE MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER. 5. MAXIMUM ELEVATION FOR ALL LOAD CENTER CIRCUIT BREAKERS SHALL NOT EXCEED 48" AFF, WITHIN DWELLING UNITS. 6. THE E.C. SHALL REFER TO ARCHITECTURAL ELEVATIONS TO COORDINATE ALL COUNTER HEIGHTS. ALL "AC" DEVICES SHALL HAVE BOTTOM OF BACK-BOX MOUNTED 4" ABOVE THE BACK/SIDE SPLASH. NOTES: S MDC 3 4 K D DOOR TO WS(x) C S D OS OS OS WOS TC PC HP R J K RA F FS D TS S TS MH S M T M T M V S SYSTEMS DISTRIBUTION AND RACEWAY FIRE ALARM LIGHTING FIXTURES WIRING DEVICES ABBREVIATIONS AND SYMBOLS FACP FA-RPS FAA C A a J J SR x x x x x x x A AMPERE(S) AC ABOVE COUNTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AIC AMPERES INTERRUPTING CAPACITY ATS AUTOMATIC TRANSFER SWITCH BFF BELOW FINISHED FLOOR C CONDUIT CATV CABLE TELEVISION CB CIRCUIT BREAKER CT CURRENT TRANSFORMER DISC DISCONNECT DW DISHWASHER DWG(S) DRAWING(S) (E) EXISTING TO REMAIN EC ELECTRICAL CONTRACTOR EF EXHAUST FAN (ER) EXISTING TO BE RELOCATED EM EMERGENCY EPO EMERGENCY POWER OFF EWC ELECTRIC WATER COOLER (R) EXISTING TO BE REMOVED F FUSE FLA FULL LOAD AMPS FD GARBAGE DISPOSAL G GROUND GC GENERAL CONTRACTOR GFI GROUND FAULT CIRCUIT INTERRUPTER HP HORSEPOWER IDF INTERMEDIATE DISTRIBUTION FACILITY IG ISOLATED GROUND ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE(S) KW KILOWATT(S) LTG LIGHTING MCA MINIMUM CIRCUIT AMPERE(S) MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION CENTER MDF MAIN DISTRIBUTION FACILITY MLO MAIN LUGS ONLY MTS MANUAL TRANSFER SWITCH MW MICROWAVE NC NORMALLY CLOSED NL NIGHT LIGHT - SEE GENERAL NOTES NO NORMALLY OPEN OAE OR APPROVED EQUAL OH OVERHEAD P POLE PART PARTIAL CIRCUIT PH PHASE PNL PANEL RCPT RECEPTACLE REF REFRIGERATOR (RL) RELOCATED SPD SURGE PROTECTION DEVICE UC UNDER COUNTER/CABINET UG UNDERGROUND UON UNLESS OTHERWISE NOTED V VOLT(S) W WATT(S) OR WIRE WG WIRE GUARD WP WEATHERPROOF XFMR TRANSFORMER POOL EQUIPMENT SCHEDULE NOTATION KITCHEN EQUIPMENT SCHEDULE NOTATION MECHANICAL EQUIPMENT SCHEDULE NOTATION DETAIL NOTE DELTA REVISION NOTE ELECTRICAL WIRE SIZE MAIN DISTRIBUTION CENTER (MDC) SURFACE MTD PANELBOARD RECESSED PANELBOARD TRANSFORMER BRANCH CIRCUIT HOMERUN CONDUIT CONCEALED IN FLOOR OR UNDERGROUND CONDUIT EXPOSED OR CONCEALED IN WALL OR CEILING RACEWAY UP RACEWAY DOWN CAPPED CONDUIT CURRENT TRANSFORMER CIRCUIT BREAKER SWITCH FUSED SWITCH GROUNDING ELECTRODE CONDUCTOR METER FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR/GRAPHIC MAP FIRE ALARM REMOTE POWER SUPPLY CONTROL MODULE MONITOR MODULE MANUAL PULLDOWN STATION WALL MOUNTED ADA STROBE ADA HORN OR SPEAKER WITH STROBE MINI HORN / STROBE ELECTROMAGNETIC DOOR HOLD OPEN SPRINKLER FLOW SWITCH SPRINKLER TAMPER SWITCH THERMAL DETECTOR PHOTOELECTRIC SMOKE DETECTOR DUCT SMOKE DETECTOR, SUPPLY OR RETURN REMOTE INDICATING LIGHT (TEST SWITCH) 120V. MOTORIZED SMOKE DAMPER RESCUE ASSISTANCE PHONE FIRE FIGHTERS PHONE JACK TTB, MDF OR IDF SYSTEM BACKBOARD TELECOMMUNICATION OUTLET FLOOR MOUNTED TELECOMMUNICATION OUTLET TELEVISION OUTLET SPEAKER - PAGING AND OR SOUND SYSTEM - INDICATES SPEAKER ZONE MICROPHONE OUTLET VOLUME CONTROL PUSH BUTTON CLOSED CIRCUIT TELEVISION CAMERA CABLE TRAY (LENGTH AS INDICATED ON DRAWINGS) LUMINAIRE TYPE, REFERENCING LUMINAIRE SCHEDULE, TYPICAL ALL FIXTURES. SUBSCRIPT, IF SHOWN, REFERENCES WALL SWITCH. WALL MOUNTED LUMINAIRE SURFACE MOUNTED LUMINAIRE RECESSED LUMINAIRE DOWNLIGHT LUMINAIRE SURFACE CEILING LUMINAIRE PENDANT LUMINAIRE WALLWASH LUMINAIRE STRIP LUMINAIRE SURFACE OR PENDANT TRACK LUMINAIRE LINEAR PENDANT LUMINAIRE (LENGTH AS INDICATED ON DRAWINGS/SCHEDULE) EXIT LUMINAIRE - SHADED INDICATES FACE/ DIRECTIONAL ARROWS AS SHOWN. BATTERY PACK EMERGENCY LUMINAIRE EMERGENCY LUMINAIRE - SHADED PROVIDE WITH INTEGRAL BATTERY BACKUP PORCELAIN LAMP HOLDER STEP LIGHT TYPE LUMINAIRE BOLLARD OR POST TOP LUMINAIRE EXTERIOR AREA LIGHT DUPLEX RECEPTACLE FOUR PLEX RECEPTACLE SINGLE RECEPTACLE COMBO RECEPTACLE/SWITCH SWITCHED DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE FLOOR MOUNTED RECEPTACLE DUPLEX/QUAD SURFACE RACEWAY CLOCK RECEPTACLE JUNCTION BOX WALL MOUNTED J-BOX FLOOR MOUNTED JUNCTION BOX MOLDED CASE CIRCUIT BREAKER IN ENCLOSURE NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MAGNETIC CONTROLLER (STARTER) COMBINATION STARTER/DISCONNECT SWITCH MOTOR RELAY TIME CLOCK PHOTOCELL THERMAL OVERLOAD SWITCH SINGLE POLE SWITCH 3-WAY SWITCH 4-WAY SWITCH KEY OPERATED SWITCH DIMMER SWITCH RECESSED DOOR SWITCH LIGHTING CONTROL SYSTEM LOW VOLTAGE DIGITAL WALL STATION. (X) INDICATES INDIVIDUAL WALL STATION ADDRESS. REFER TO LIGHTING CONTROL ONELINE DRAWING. SINGLE RELAY OCCUPANCY SENSOR/SWITCH. DOUBLE RELAY OCCUPANCY SENSOR/SWITCH. CEILING MOUNTED OCCUPANCY SENSOR. WALL MOUNTED OCCUPANCY SENSOR. S S S S S S S x CONTROL INTENT SCHEDULE NOTATION x LIGHTING CONTROL DEVICE SCHEDULE NOTATION TP TAMPER-PROOF UNDERWATER LIGHT EXISTING STRUCTURAL STEEL POOL SHELL BONDING GRID NEW STRUCTURAL STEEL PERIMETER BONDING GRID POOL BONDING REQUIREMENTS 1. ALL GROUNDING AND BONDING OF ALL METALLIC PARTS ASSOCIATED WITH THE POOL AND WHIRLPOOL ARE TO BE IN COMPLIANCE WITH 2014 NEC SECTION 680. 2. THE POOL CONCRETE REINFORCING STEEL REBAR SHALL BE BONDED WITH STEEL TIE WIRES, OR EQUAL, AND SHALL THEREBY SERVE AS A COMMON BONDING GRID FOR ALL PARTS REQUIRED BY N.E.C. 2011 680.26 TO BE BONDED TOGETHER. BONDING LUGS TO BE SUPPLIED BY ELECTRICAL CONTRACTOR. 3. ISOLATED PARTS THAT ARE NOT MORE THAN 4" IN ANY DIMENSION AND DO NOT GENERATE INTO THE POOL STRUCTURE MORE THAN 1" SHALL NOT REQUIRE BONDING. 4. BONDING CONDUCTORS SHALL BE MINIMUM #8 SOLID COPPER, INSULATED. E.C. SHALL COORDINATE APPROVED CONNECTOR TYPE AND METHOD WITH LOCAL ELECTRICAL AND/OR POOL INSPECTOR. 5. SPECIFIC MANUFACTURER'S INSTRUCTIONS REGARDING BONDING OR GROUNDING OF POOL EQUIPMENT, WHETHER INDICATED HEREIN OR NOT, SHALL BE STRICTLY FOLLOWED. 6. THE COMMON BONDING GRID SHALL NOT BE CONNECTED TO ANY ELECTRICAL DISTRIBUTION EQUIPMENT. 7. ANY PARTS IN ADDITION TO THOSE DESCRIBED HEREIN THAT ARE INDICATED BY POOL CONTRACTOR OR LOCAL INSPECTION AUTHORITY SHALL BE BONDED TO THE COMMON BONDING GRID WITH NO ADDITIONAL COSTS INCURRED BY THE OWNER. 8. THE ELECTRICAL CONTRACTOR SHALL COORDINATE BONDING WITH POOL CONTRACTOR AND GENERAL CONTRACTOR. 9. THE FOLLOWING PARTS SHALL BE BONDED TOGETHER AND CONNECTED TO THE COMMON BONDING GRID (WHERE APPLICABLE OR PROVIDED): A. ALL METALLIC PARTS OF THE POOL STRUCTURE, INCLUDING COPYING STONES, DECK, PERMANENT PLAY STRUCTURES, PERMANENT EXERCISE STRUCTURES. B. ALL METAL FITTINGS WITHIN OR ATTACHED TO THE POOL STRUCTURE. C. METAL PARTS ASSOCIATED WITH THE POOL WATER CIRCULATING SYSTEM, INCLUDING PUMPS, FILTERS, AND HEATERS. D. METAL PARTS ASSOCIATED WITH POOL COVERS. E. METAL SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL PARTS WITHIN 5 FEET HORIZONTALLY OF INSIDE WALLS OF POOL AND WITHIN 12 FEET ABOVE THE MAXIMUM WATER LEVEL OF THE POOL. F. METAL PARTS ASSOCIATED WITH OBSERVATION STANDS, TOWERS, PLATFORMS, AND DIVING STRUCTURES. G. METAL PARTS ASSOCIATED WITH THE POOL SLIDE TOWER, SLIDE STAIRS, AND ASSOCIATED SLIDE STRUCTURE. AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 NTS 10 / 3 1 / 2 0 1 6 1 1 : 1 5 : 4 3 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL COVER SHEET E000 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O COVERSHEET NOTES 1 THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. 2 MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. 3 MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHER RECOGNIZED TESTING LAB. 4 ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS, EXCEPT AS NOTED OTHERWISE. 5 THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. 6 THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENCIES, FOR THEIR APPROVAL. 7 THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. 8 FOR ALL JOBS THAT INCLUDE DEMOLITION WORK BY THE ELECTRICAL CONTRACTOR, DURING AND AFTER DEMOLITION, EC SHALL MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING DEVICES THAT ARE TO REMAIN. EC SHALL REMOVE, RELOCATE, AND/OR REWORK ANY CONDUIT AND WIRING TO FACILITATE THE NEW CONSTRUCTION SCOPE OF WORK. FOR A LUMINAIRES THAT ARE EXISTING TO REMAIN OR EXISTING TO BE RELOCATED, EC SHALL CLEAN LENSES AND REPLACE ALL EXTINGUISHED LAMPS, UON. 9 THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. 10 ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. 11 ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTION OF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE. 12 E.C. IS TO REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL FIRE RATED PENETRATION INSTALLATION REQUIREMENTS. E.C. IS TO NOTIFY ENGINEER AND ARCHITECT PRIOR TO INSTALLING ANY FIXTURES WITHIN A FIRE RATED CEILING OR WALL. FIRE RATING MUST BE MAINTAINED FOR THIS TYPE OF INSTALLATION WITH DRYWALL TENTING. 13 E.C. SHALL PROVIDE COORDINATION STUDY OF NEW AND/OR NEW GEAR COMBINED WITH EXISTING GEAR DURING THE SUBMITTAL PROCESS. 14 SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES, PARTIAL SUBMITTALS WILL NOT BE REVIEWED. 15 PROVIDE THE FOLLOWING INFORMATION, PER IECC 2015 C408.2.5.2 TO THE PARTY RESPONSIBLE FOR PROJECT COMMISSIONING PLAN (COMMISSIONING AGENT/ MECHANICAL ENGINEER) AND ELECTRICAL ENGINEER. A. CUTSHEETS FOR ALL INSTALLED LIGHTING AND LIGHTING CONTROLS. B. OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF INSTALLED LIGHTING, REQUIRED ROUTINE MAINTENANCE ACTIONS, CLEANING AND RECOMMENDED RELAMPING SHALL BE CLEARLY IDENTIFIED. C. SCHEDULE FOR INSPECTING AND RECALIBRATING ALL LIGHTING CONTROLS. INSPECTION OF ALL LIGHTING CONTROLS SHALL BE PERFORMED PRIOR TO ELECTRICAL ENGINEER'S COMMISSIONING SITE VISIT. RECALIBRATION OF LIGHTING CONTROLS SHALL BE PERFORMED FOLLOWING SITE VISIT AND SHALL BE BASED UPON THE RECOMMENDATIONS OF THE ELECTRICAL ENGINEER. 16 ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. 17 CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE ELECTRICAL UTILITY COMPANY WITHIN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THE REVIEW, APPROVAL, ALL ASSOCIATED DOWN TIME, CONSTRUCTION SCHEDULING, DELIVERY, AND INSTALLATION OF THE UTILITY TRANSFORMER. NOTIFY OWNER OF SCHEDULING CONFLICTS. 18 ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED. PANELBOARD SHALL BE MARKED WHERE THE SOURCE OF POWER SUPPLY ORIGINATES, AND IF SERIES COMBINATION SYSTEMS ARE UTILIZED AND THEIR LISTED AMPERE RATING. 19 DO NOT SHARE NEUTRAL CONDUCTORS FOR MULTIWIRE BRANCH CIRCUITS. WHERE THE E.C. PROPOSES THE USE OF SHARED NEUTRAL CONDUCTORS OR SHARED NEUTRAL CONDUCTORS ARE REQUIRED (SUCH AS POWERED FURNITURE SYSTEMS), HANDLE TIES SHALL BE PROVIDED ON THE CIRCUIT BREAKERS, WITH SHARED NEUTRALS, SUCH THAT IT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. ALL HANDLE TIES ARE REQUIRED TO BE INDICATED ON THE PANELBOARD SHOP DRAWINGS. 20 SHOULD ACTUAL FIELD CONDITIONS REQUIRE INDICATED CIRCUIT DESIGNATIONS TO VARY, INDICATE THE CIRCUIT NUMBER USED ON THE "AS-BUILT" DRAWINGS. 21 ALL SERVICE EQUIPMENT (OTHER THAN IN DWELLING UNITS) SHALL BE LEGIBLY MARKED IN THE FIELD BY THE ELECTRICAL CONTRACTOR WITH THE MAXIMUM AVAILABLE FAULT CURRENT AS INDICATED WITHIN THESE DOCUMENTS. THE FIELD MARKING(S) SHALL COMPLY WITH ELECTRICAL SPECIFICATIONS FOR READABILITY AND DURABILITY. 22 ALL NEW CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED. 23 ALL WIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE SHALL BE PLENUM RATED. 24 ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO ENCLOSE RECEPTACLES. 25 IN EXPOSED AND SUSPENDED CEILING APPLICATIONS, ROUTE CONDUIT AS CLOSE TO STRUCTURAL SLAB OR DECK AS POSSIBLE, AND SUPPORT CONDUIT AND JUNCTION BOXES DIRECTLY FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE. 26 ALL EXPOSED CONDUIT SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE, AND SHALL BE INSTALLED PARALLEL AND CLOSE TO STRUCTURAL MEMBERS. GENERAL CONTRACTOR SHALL PAIN CONDUIT TO MATCH ADJACENT FINISHES. 27 WHERE FLOOR FITTINGS REQUIRE PENETRATION OF THE FLOOR SLAB, THEY SHALL BE STANDARD DEVICE LISTED BY UL FOR THE PURPOSE AND HAVE A UL FIRE RATING EQUAL TO THE FLOOR RATING. FLOOR SERVICE BOXES SHALL BE MODULAR, ADJUSTABLE FLUSH TYPE, DUAL SERVICE UNITS SUITABLE FOR WIRING METHOD USED. COMPARTMENT BARRIERS SHALL SEPARATE POWER FROM LOW VOLTAGE CABLING. PROVIDE RECTANGULAR SERVICE PLATE WITH SATIN FINISH. 28 ALL RECEPTACLES SHALL BE SPECIFICATION GRADE NEMA 5-20R, UNLESS OTHERWISE NOTED. 29 ALL LIGHT SWITCHES SHALL BE SPECIFICATION GRADE, QUIET OPERATION RATED 120/277 VOLT, 20 AMPS, UNLESS OTHERWISE NOTED. 30 ALL FACE PLATE AND DEVICE COLORS SHALL BE APPROVED BY ARCHITECT OR OWNER/LEASEE. 31 PROVIDE LUMINAIRES SHOWN AS SHADED WITH EMERGENCY BATTERY BALLASTS. EMERGENCY LUMINAIRES SHALL SENSE UNSWITCHED POWER TO THE SPACE AND OPERATED AUTOMATICALLY UPON LOSS OF NORMAL POWER. ALL SHADED LUMINAIRES WITH 2' AND 4' LAMPS OR LONG BIAX LAMPS SHALL HAVE ONE (1) 90 MINUTE, TWO LAMP, 1400 LUMEN EMERGENCY BALLAST. ALL SHADED LUMINAIRES WITH COMPACT FLUORESCENT LAMPS SHALL HAVE A FACTORY INSTALLED 90 MINUTE EMERGENCY BALLAST. ALL EMERGENCY LUMINAIRES SHALL HAVE REMOTE TEST SWITCHES AND VISIBLE INDICATING LIGHTS. CONNECT THE EMERGENCY BATTERY BALLAST TO THE UN-SWITCHED LEG OF THE LIGHTING CIRCUIT INDICATED. 32 ALL BATTERY BACKUP EMERGENCY LIGHTING AND EXIT LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL SWITCHING, UON. 33 UNLESS OTHERWISE NOTED, LUMINAIRES DESIGNATED AS NIGHT LIGHT (NL) SHALL BE CONNECTED AHEAD OF LOCAL SWITCHING AND REMAIN ON 24 HOURS A DAY. 34 ALL DIMMED LIGHTING CIRCUITS ARE TO RECEIVE DEDICATED NEUTRALS. DO NOT SHARE NEUTRALS ON DIMMED LIGHTING CIRCUITS. 35 WHERE DUAL LEVEL SWITCHING IS INDICATED, THE SWITCH CLOSEST TO THE DOOR SHALL CONTROL ALL OUTER LAMPS IN THE INDICATED LUMINAIRE AND THE ADJACENT SWITCH SHALL CONTROL ALL INNER LAMP(S) IN THE INDICATED LUMINAIRES, UON. 36 PROVIDE OWNER WITH A COMPLETE LISTING OF ALL LAMPS UTILIZED ON THE PROJECT INCLUDING MANUFACTURER AND CATALOG INFORMATION. PROVIDE A SUGGESTED SOURCE, INCLUDING CONTACT NAME AND PHONE NUMBER, FOR REORDERING. 37 THE CONTRACTOR SHALL VERIFY THE CEILING TYPE BEFORE ORDERING LIGHTING. 38 ROUGH-IN FOR MECHANICAL EQUIPMENT SHALL ONLY OCCUR AFTER MECHANICAL EQUIPMENT SUBMITTALS ARE THOROUGHLY REVIEWED FOR CHANGES. NOTIFY ENGINEER OF ANY DISCREPANCIES. 39 FINAL LAYOUT AND QUANTITY OF ALL FIRE ALARM DEVICES SUBJECT TO APPROVAL OF LOCAL AUTHORITY HAVING JURISDICTION. 40 PROVIDE NEMA 3R AND CORROSION RESISTANT ELECTRICAL EQUIPMENT AND WIRING METHODS WITHIN POOL EQUIPMENT, POOL AND WHIRLPOOL AREAS. REFER TO DRAWINGS AND SPECIFICATION. 41 THE POWER AND CONTROL REQUIREMENTS FOR ALL EQUIPMENT CONNECTIONS SHALL BE CONFIRMED WITH APPROVED SHOP DRAWINGS PRIOR TO ELECTRICAL ROUGH-IN. FINAL POWER REQUIREMENTS, DIMENSIONED ROUGH-IN LOCATIONS, LOW VOLTAGE SYSTEM CONNECTIONS, ETC. SHALL BE CONFIRMED AND MODIFIED AS REQUIRED. 42 ALL DEVICES IN OR ABOVE COUNTERS SHALL HAVE LOCATIONS AND MOUNTING HEIGHTS CONFIRMED WITH ARCHITECTURAL ELEVATIONS & OWNER PRIOR TO ROUGH-IN. ANY ADJUSTMENTS TO MOUNTING HEIGHTS REQUIRED BY LACK OF COORDINATION WILL BE AT THE CONTRACTOR'S EXPENSE. 43 ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST. 44 G.C. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. TURN EQUIPMENT OVER TO OWNER AS INDICATED OR RECYCLE/DISCARD ALL EQUIPMENT AS REQUIRED. E.C. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. 45 WHERE EXISTING CEILINGS ARE REVISED FROM ACCESSIBLE TO NON-ACCESSIBLE, CONTRACTOR IS TO INCLUDE IN HIS BID THE COSTS ASSOCIATED WITH RELOCATING ALL ELECTRICAL EQUIPMENT REQUIRING ACCESS ABOVE THE EXISTING CEILING TO A NEW ACCESSIBLE CEILING LOCATION APPROVED BY ARCHITECT AND ENGINEER. THE USE OF ACCESS PANELS IN THE NEW CEILING TO AVOID RELOCATION OF THIS EQUIPMENT IS NOT ACCEPTABLE. 46 CONTRACTOR TO CONDUCT FUNCTIONAL TESTING OF LIGHTING CONTROLS EQUIPMENT AS REQUIRED BY IECC 2012/2015, SECTION C408.3. AFTER THIS TESTING IS OBSERVED AND COMPLETED, THE REGISTERED DESIGN PROFESSIONAL OR COMMISSIONING AUTHORITY SHALL PROVIDE DOCUMENTATION TO THE AHJ THAT CERTIFIES THAT THE INSTALLATION MEETS THE DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405. NTS1DEVICE MOUNTING HEIGHT SHEET LIST SHEET NUMBER SHEET NAME E000 ELECTRICAL COVER SHEET E010 ELECTRICAL SITE PLAN E102 ELECTRICAL POWER PLAN - LOWER LEVEL E103 ELECTRICAL POWER PLAN - UPPER LEVEL - NORTH E104 ELECTRICAL POWER PLAN - UPPER LEVEL - SOUTH E105 ELECTRICAL ROOF PLAN E106 ELECTRICAL ENLARGED POWER PLANS E112 ELECTRICAL LIGHTING PLAN - LOWER LEVEL E113 ELECTRICAL LIGHTING PLAN - UPPER LEVEL - NORTH E114 ELECTRICAL LIGHTING PLAN - UPPER LEVEL - SOUTH E400 ELECTRICAL ONE-LINE DIAGRAM E401 ELECTRICAL DIAGRAMS E402 LIGHTING CONTROL SCHEDULES AND DIAGRAMS E403 LIGHTING CONTROL DIAGRAMS E500 ELECTRICAL SCHEDULES E501 ELECTRICAL SCHEDULES E502 ELECTRICAL SCHEDULES E503 ELECTRICAL SCHEDULES E504 ELECTRICAL SCHEDULES E505 ELECTRICAL SCHEDULES NTS4POOL BONDING DETAIL T T T S S S S S S S S S S SS SS SS 868 11 77 8 HC 17 4 12 13 12 9 4 HC 4 15 16 4 HC 16 4 J 1 2 3 4 5 6 7 'MSD' EA1 RP2A-4 EA1 RP2A-4 EA1 RP2A-6 EA2 RP2A-4 EB3 RP2A-8 EB3 RP2A-9 EB4 RP2A-8 EP5 RP2A-5 EA1 RP2A-4 EA1 RP2A-6 EA2 RP2A-4 EA1 RP2A-4 EA1 RP2A-4 EA2 RP2A-6 EA2 RP2A-6 EB3 RP2A-9 EB3 RP2A-8 EB3 RP2A-8 EB3 RP2A-8 EB3 RP2A-9 EB3 RP2A-8 EB3 RP2A-8 EB3 RP2A-8 EB3 RP2A-9 EP5 RP2A-7 EP5 RP2A-5 EP5 RP2A-7 EB4 RP2A-8 EB4 RP2A-8 EB4 RP2A-8 EP5 RP2A-7 EB4 RP2A-8 EB4 RP2A-8 EP5 RP2A-5 8 9 GFI WP GFI WP GFI WP GFI WP GFI WP 10 ESTES VALLEY COMMUNITY CENTER 11 LP2B-82 LP2B-82 LP2B-82 LP2B-83 LP2B-83 LP2B-83 LP2B-83 LP2B-83 GFI WP GFI WP GFI WP GFI WP GFI WP LP2B-82 LP2B-82 LP1B-83 B ATTACH TO REBAR WITH BONDING CLAMP I ANCHOR BOLT ANCHOR BOLT DATA 4-#4 BARS VERTICAL ELEVATION H EA1 KEY POLE 25'0" HEIGHT OVERALL 4" A F G 24" H PER MANUFACTURER B SIZE C D 6" 8'0" E F 10'0" G TOP VIEW 36" I BASE PLATE 1" CHAMFER BASE COVER ATTACH TO BONDING LUG ON POLE D A C HAND HOLE E H BELOW TOP 5" OF FOUNDATION #3 HORIZ. TIES @ 12" O.C. PVC RIGID CONDUIT TYP. FINISH GRADE VARIES 3-#3 HORIZ. TIES WITHIN TOP 5" OF FOUNDATION EA2 25'0"4"24"PER MANUFACTURER 6" 8'0" 10'0" 36" PER MANUFACTUREREP5 15'0"4"24"6" 8'0" 10'0" 36" PER MANUFACTUREREB3/EB4 3'0"4-3/8" AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 As indicated 10 / 3 1 / 2 0 1 6 1 1 : 1 6 : 0 0 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL SITE PLAN E010 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1" = 30'-0"1 ELECTRICAL SITE PLAN NTS2POLE BASE DETAIL GENERAL NOTES A UNLESS OTHERWISE NOTED, ALL CIRCUIT NUMBERS INDICATED ON THIS SHEET SHALL REFER TO CIRCUIT ORIGINATING IN PANELBOARDS BASED UPON THE FOLLOWING CONVENTION, (THIS SHEET ONLY): TBD-# = CIRCUIT TO PANEL 'TBD' B EC SHALL REFER TO SECURITY DRAWINGS AND IRRIGATION DRAWINGS FOR ADDITIONAL CONDUIT, WIRING, AND CIRCUITY TO BE PROVIDED IN ADDITION TO THAT SHOWN ON THE ELECTRICAL DRAWINGS. EC SHALL PROVIDE EXPANSION JOINT FITTINGS FOR ALL CONDUITS AS REQUIRED BY STRUCTURAL DRAWINGS. ALL EXTERIOR LIGHTING CIRCUITS SHALL UTILIZE A MINIMUM WIRE SIZE OF #8AWG COPPER, UNLESS OTHERWISE NOTED. C D KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 EXISTING UTILITY PAD MOUNTED TRANSFORMER TO BE DEMOLISHED. REFER TO ELECTRICAL DEMOLITION ONE-LINE DIAGRAM FOR MORE INFORMATION. 2 APPROXIMATE ROUTING OF EXISTING UTILITY PRIMARY. 3 APPROXIMATE ROUTING OF EXISTING LOW-VOLTAGE/TELEPHONE SERVICE TO EXISTING MTTB IN MAIN ELECTRICAL ROOM. 4 LOCATION OF EXISTING MAIN ELECTRICAL ROOM AND EXISTING ELECTRICAL SERVICE EQUIPMENT. 5 APPROXIMATE LOCATION OF EXISTING UTILITY POLE. 6 APPROXIMATE LOCATION OF EXISTING TELEPHONE SERVICE PEDESTAL. 7 LOCATION OF NEW 480/277V, 3-PHASE, PAD MOUNTED UTILITY TRANSFORMER. ALL PRIMARY TRENCHING/BACKFILLING AND CONDUIT BETWEEN THE UTILITY VAULT AND NEW TRANSFORMER LOCATION SHALL BE PROVIDED/INSTALLED BY UTILITY. PRIMARY LINES SHALL BE 4' DEEP WITH RED WARNING TAPE INSTALLED AT 2' DEPTH. REFER TO UTILITY REQUIREMENTS FOR CONDUIT PRIMARY PIPE RACK AND ADDITIONAL CONDUIT REQUIREMENTS. THE EC SHALL PERFORM ALL TRENCHING/BACKFILLING FOR THE TRANSFORMER SECONDARY FEEDERS, AND PROVIDE/INSTALL ALL SECONDARY CONDUIT. EC SHALL COORDINATE ALL CONDUIT ROUTING IN FIELD AND VERIFY PRIMARY ROUTING TO TRANSFORMER PRIMARY CONNECTION POINT WITH UTILITY PRIOR TO WORK COMMENCE. PRPA SHALL MAKE ALL FINAL CONNECTIONS OF PRIMARY AND SECONDARY FEEDERS REQUIRED AT THE TRANSFORMER LANDINGS. EC SHALL COORDINATE ALL UTILITY TRANSFORMER PAD INSTALLATION REQUIREMENTS, CLEARANCES, PAD ORIENTATION, UTILITY METERING REQUIREMENTS AND INSTALLATION OF METERING EQUIPMENT WITH UTILITY PRIOR TO WORK COMMENCE. 8 APPROXIMATE ROUTING OF TRANSFORMER SECONDARY FEEDER TO MAIN SERVICE DISCONNECT. REFER TO ELECTRICAL ONE-LINE DIAGRAM FOR MORE INFORMATION. 9 APPROXIMATE ROUTING OF NEW LOW-VOLTAGE/TELEPHONE SERVICE FROM NEW TELEPHONE SERVICE PEDESTAL TO NEW LAN LOCATION. EC SHALL COORDINATE EXACT ROUTING AND TERMINATION LOCATIONS PRIOR TO ROUGH-IN. 10 PROVIDE (1) 1" AND (1) 1-1/4" UNDERGROUND CONDUIT FOR 120V, 20-AMP POWER CONNECTION AND DATA CONNECTION TO INTERNALLY ILLUMINATED MONUMENT SIGN. POWER BRANCH CIRCUIT TO BE 2#8, 1#10G (UPSIZED FOR VOLTAGE DROP). COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 11 CONDUIT LOCATION FOR (1) 1-1/2" ORANGE PVC SPARE CONDUIT FROM TRANSFORMER STUBBED INTO BUILDING PROVIDED BY UTILITY AND INSTALLED BY CONTRACTOR. DN DN S J J J J J CLG J CLG T SS J CUH 3 CUH 4UH 5 CUH 5 TF 2 UH 4 J J CLG J CLG J J J J J J J JJ J S S S J S J CLG J CLG J CLG EF 16 J J J ELEV 1 S T SP 1 J J J A B 1 L 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F K A2 A3 AG AF AA A.1 B.7 H H J J J.3 12 5 GFI WP GFI WP GFI WP GFI WP RECV & STOR 115 CLASSROOM 114 MEN 110 WOMEN 111 ELEV 117 GYM 131 P&R DIRECTOR 108 VEST 101 KITCHEN 112 WOMEN 104 EMP ENTRY 103 STORAGE 143 COMMUNITY 141 COMMUNITY KITCHEN 142 STOR 113 STRENGTH 123 MP GROUP EX 124 GYM STORAGE 132 EXIT STAIR S10 STRENGTH 123 STAFF 107 GAMES 106 LOUNGE 102 JR GOLF 121 HITTING 122 MEN 105 ELEC 109 GFI WP GFI WP 3 3 3 3 'LP1B' 'HL1B' 'HM1B' 'RP1B' STORAGE 118 GFI WP +42" GFI +42" GFI AC AC AC AC GFI AC GFI 4 5 3 6 7 8 +72" +72" 9 FAN FAN1010 10 10 11 11 12 13 13 14 13 15 13 4 4 4 4 4 4 16 +72" +72" +72" +72" +72" +72" GFI GFI GFI EWC GFI REF AC GFI AC GFI +60" GFI MW AC GFI 17 GFI EWC CLG CLG CLG CLG 16 9 E102 2 'T1B' WP FS TS FS TS GD 2021 22 22 22 22 RANGE 30A/2P AC GFI AC GFI GFI EWC 3 3 23 23 LP1B-2 LP1B-2 LP1B-2 LP1B-2 LP1B-4 LP1B-4 LP1B-4 LP1B-4 LP1B-4 LP1B-4 LP1B-5 LP1B-9 LP1B-8 LP1B-10 LP1B-5 LP1B-11 LP1B-5 LP1B-9 LP1B-5 LP1B-5 LP1B-8 LP1B-7 LP1B-7 LP1B-6 LP1B-6 LP1B-6 LP1B-6 LP1B-6 LP1B-5 LP1B-12 LP1B-12 LP1B-14 LP1B-15 LP1B-29LP1B-26 LP1B-12 LP1B-12 LP1B-12 LP1B-13 LP1B-12 LP1B-72 LP1B-71 LP1B-70 LP1B-16LP1B-69 LP1B-16 LP1B-16 LP1B-51 LP1B-12 LP1B-12 LP1B-53LP1B-54 LP1B-55 LP1B-56 LP1B-57 LP1B-58 LP1B-59 LP1B-18 LP1B-19 LP1B-19 LP1B-19 LP1B-18 LP1B-18 LP1B-20 LP1B-20 LP1B-20 LP1B-21 LP1B-21 LP1B-21 LP1B-27 LP1B-24 LP1B-25 LP1B-27 LP1B-27LP1B-27 LP1B-25 LP1B-22 LP1B-22 LP1B-23 LP1B-23 LP1B-25 LP1B-25 LP1B-23 LP1B-31 LP1B-28 LP1B-33 LP1B-39LP1B-34 LP1B-32 LP1B-30LP1B-39 LP1B-39 LP1B-36 LP1B-41 LP1B-39 LP1B-39 LP1B-38 LP1B-38LP1B-25 LP1B-35,37 LP1B-40 LP1B-40 LP1B-40 LP1B-40 LP1B-45 LP1B-45 LP1B-27 LP1B-45 LP1B-42 LP1B-45 LP1B-45 LP1B-42 LP1B-64 LP1B-64 LP1B-64 LP1B-64 LP1B-45 LP1B-39 LP1B-44 LP1B-44 LP1B-50 LP1B-50 LP1B-46 LP1B-46 LP1B-46 LP1B-48 LP1B-49 LP1B-61 LP1B-61 LP1B-61 LP1B-61 LP1B-63 LP1B-61 LP1B-60 LP1B-62 LP1B-60 LP1B-60 LP1B-68 LP1B-60 LP1B-60 LP1B-60 12 LP1B-70 LP1B-69 LP1B-70 LP1B-70LP1B-69 LP1B-70 LP1B-66 LP1B-68 LP1B-65 LP1B-67 LP1B-68 LP1B-68 LP1B-69 LP1B-16 LP1B-73 LP1B-73 LP1B-42 LP1B-42 LP1B-64LP1B-64 LP1B-42 LP1B-42 1010 10 10 GFI LP1B-12 E106 2 14 LP1B-68 25 26 LP1B-78 LP1B-79 A4 A5 AH K 2 GFI 18 19 1 GFI WP 24 LP1B-43 LP1B-75 LP1B-80 LP1B-81 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 As indicated 10 / 3 1 / 2 0 1 6 1 1 : 2 8 : 4 0 A M C: \ U s e r s \ k m e n y h a r t \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e nt r a l _ k m e n y h a r t @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL POWER PLAN - LOWER LEVEL E102 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NORTH 1/8" = 1'-0"1 LOWER LEVEL POWER PLAN KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 APPROXIMATE LOCATION OF ELEVATOR MANUFACTURER PROVIDED ELEVATOR POWER CONTROL WITHIN THE PIT. THE ELEVATOR CONTROL PANEL INCLUDES INTEGRAL 80A/3P CIRCUIT BREAKER DISCONNECT WITH SHUNT TRIP COIL FOR CONNECTION TO THE FIRE ALARM SYSTEM. 2 PROVIDE KEYED SWITCH FOR ELEVATOR CAB POWER AND LIGHTING CIRCUIT. 3 PROVIDE FIRE ALARM DEVICE WITH MANUFACTURER'S STANDARD WIRE GAURD PROTECTION. 4 FLOORBOX TO BE HUBBELL RECESSED CONCRETE WITH SMOOTH METALLIC COVER, SIMILAR TO HUBBELL LCFBCXX (OR APPROVED EQUAL) CARPET APPLICATIONS TO BE FLANGE COVERPLATE. ALL COVERPLATES SHALL BE FLUSH WITH FLOOR FINISH TO REDUCE TRIPPING HAZARDS. EC SHALL PROVIDE 1-1/2"C FOR DATA AND 3/4"C FOR POWER ROUTED UP NEAREST WALL THROUGH ACCESSIBLE CEILING. EC TO VERIFY SPECIFICATIONS PRIOR TO ORDERING. EC SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH OW NER/ARCHITECT PRIOR TO ROUGH-IN ARCHITECT SHALL CHOOSE COVER PLATE FINISH. 5 PROVIDE 120V, 30mA GROUND FAULT PROTECTED EQUIPMENT CONNECTION FOR HEAT TRACE. COORDINATE EXACT LOCATION AND HEAT TRACE LENGTH WITH ARCHITECT/OWNER PRIOR TO INSTALLATION. COORDINATE ALL CONTROLLER CONNECTION REQUIREMENTS WITH APPROVED EQUIPMENT SHOP DRAWINGS PRIOR TO INSTALLATION. 6 CEILING MOUNTED JUNCTION BOX FOR 120V POWER CONNECTION TO GOLF SIMULATOR PROJECTOR SYSTEM. 7 CEILING MOUNTED JUNCTION BOX WITH 1"C BACK TO WALL JUNCTION BOX FOR GOLF SIMULATOR PROJECTOR SYSTEM AV CABLING. 8 APPROXIMATE LOCATION OF COMMUNICATIONS CONDUIT, FROM UTILITY CONNECTION CABINET AT PROPERTY LINE, ENTERING BUILDING. EXTEND CONDUIT FROM UNDER SLAB, THROUGH LOWER FLOOR AREA, UP INTO STUB OUT 8" ABOVE UPPER FLOOR IT ROOM. 9 JUNCTION BOX MOUNTED ABOVE CEILING FOR 120V, 20A POWER CONNECTION TO CEILING MOUNTED MOTORIZED PROJECTION SCREEN OPERATOR. EC SHALL COORDINATE EXACT LOCATION/CONTROL/CONNECTION REQUIREMENTS WITH APPROVED AV DRAWINGS PRIOR TO ROUGH IN. 10 RECEPTACLE IS MOUNTED IN MIRROR WALL. COORDINATE FACEPLATE FINISH WITH ARCHITECT. 11 FUTURE SCOREBOARD LOCATION. SURFACE MOUNTED JUNCTION BOX MOUNTED ON GYM SIDE OF TRACK FOR FUTURE MOUNTING OF SCOREBOARD TO TRACK WALL. PROVIDE JUNCTION BOX WITH BLANK FACEPLATE AND 3/4" CONDUIT. CONDUIT FOR FUTURE SCOREBOARD SHALL BE SUNK IN TRACK DECK CONCRETE. 12 SCOREBOARD POWER LOCATION ON FRONT OF TRACK. EC SHALL COORDINATE ELECTRICAL REQUIREMENTS AND EXACT LOCATION/ELEVATION WITH FINAL ARCHITECTURAL DRAWINGS AND APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN. CONDUIT FOR SCOREBOARD SHALL BE SUNK IN TRACK DECK CONCRETE. 13 WALL MOUNTED RECESSED JUNCTION BOX WITH 1"C TO ROOM JOIST SPACE FOR SCOREBOARD COMMUNICATIONS CABLING/RACEWAY. 14 WALL MOUNTED RECESSED JUNCTION BOX WITH 1"C TO ABOVE ACCESSIBLE CEILING FOR SCORERS TABLE COMMUNICATIONS CABLING/RACEWAY. 15 WALL MOUNTED JUNCTION BOXES WITH 3/4"C TO ABOVE ACCESSIBLE CEILING FOR DIVIDER CURTAIN AND BASKET HEIGHT ADJUSTER CONTROLS LOCATION. EXACT LOCATION, QUANTITY, AND CONNECTION REQUIREMENTS TBD. 16 120V DUPLEX AND DATA RECEPTACLES MOUNTED FLUSH IN CEILING FOR PROJECTOR POWER AND LOW VOLTAGE CABLING CONNECTIONS. EC SHALL COORDINATE EXACT REQUIREMENTS WITH APPROVED AV DRAW INGS PRIOR TO ROUGH-IN. 17 120V POWER CONNECTION FOR GAS FIREPLACE IGNITION CIRCUIT UNDER ALTERNATE. EC SHALL COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS. 18 JUNCTION BOX FOR 120V, 20A POWER CONNECTION TO ELEVATOR CAB. EC SHALL COORDINATE JUNCTION BOX LOCATION WITH APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN. 19 JUNCTION BOX AND 3/4" CONDUIT TO ABOVE ADJACENT ACCESSIBLE CEILING FOR ELEVATOR LOW VOLTAGE TELEPHONE CABLING RACEWAY. CONTRACTOR SHALL PROVIDE (1) CAT6 CABLE FROM 110BLOCKS LOCATED WITHIN THE LAN ROOM FOR CONNECTION TO ELEVATOR CONTROL PANEL. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN. 20 JUNCTION BOX FOR 120V POWER CONNECTION TO MOTORIZED AUTOMATED ACCESS DOOR OPERATOR. EC SHALL MAKE ALL NECESSARY INTERCONNECTIONS BETWEEN JUNCTION BOX, SECURITY SYSTEM, OPERATOR MOTOR, AND PUSH PAD LOCATIONS PER MANUFACTURER'S REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH APPROVED EQUIPMENT SHOP DRAWINGS AND SECURITY SYSTEM INSTALLER. 21 JUNCTION BOX FOR 120V POWER CONNECTION TO MOTORIZED AUTOMATED ACCESS DOOR OPERATOR. EC SHALL MAKE ALL NECESSARY INTERCONNECTIONS BETWEEN JUNCTION BOX, OPERATOR MOTOR, AND PUSH PAD LOCATIONS PER MANUFACTURER'S REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH APPROVED EQUIPMENT SHOP DRAWINGS. 22 WALL MOUNTED RECESSED JUNCTION BOX WITH 3/4"C FOR INSTALLATION OF MOTORIZED ASSIST PUSH PAD DEVICE INSTALLATION. COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN. 23 PROVIDE 120V, 10A POWER FOR SECURITY SYSTEM DOOR HOLD. REFER TO SECURITY DRAWINGS FOR ADDITIONAL INFORMATION. 24 PROVIDE 120V, 20-AMP POWER CONNECTION TO ELEVATOR SUMP PUMP CONROL PANEL. COORDINATE EXACT LOCATION IN THE FIELD WITH OTHER EQUIPMENT IN ELEVATOR MACHINE ROOM. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 25 JUNCTION BOX LOCATED ABOVE ACCESSIBLE CEILING PLANE FOR 120V POWER CONNECTION TO VAV CONTROLS TRANSFORMER. EC SHALL COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 26 JUNCTION BOX LOCATED ABOVE ACCESSIBLE CEILING FOR 120V POWER CONNECTION TO FIRE SMOKE DAMPER. EC SHALL COORDINATE EXACT LOCATION AND FIRE ALARM SYSTEM CONNECTION REQUIREMENTS WITH APPROVED MECHANICAL SHOP DRAWINGS PRIOR TO ROUGH-IN. GENERAL NOTES A EC SHALL REFER TO AUDIO VISUAL AND SECURITY SYSTEMS DRAWINGS FOR ADDITIONAL EC PROVIDED AND INSTALLED CONDUIT, WIRING, AND CIRCUITING. 1/4" = 1'-0"2 ELEVATOR MECHANICAL ROOM & PIT ENLARGED POWER PLAN S J J J J EF 7 EF 8 CF 1 UH 1 CF 2 J CLG S S S T S J UH 6 J J J J DSIU 1 T T TF 1 A B L 3 4 6 7 A4 A5 8 AE AD AH C D E F G K A3 AG AF A.1 B.7 H H J J.3 12 12 5 5 DESK STAFF 272 WOMEN 204 MEN 203 WATER & FIRE ENTRY 273 EXEC DIR 281 M/P GROUP EX 262 CARDIO 261 ST. 263 LOBBY 202 FINANCE 287 FACILITY DIR 285 HR 283 ADMIN 271 COPY 278 LAN 276 ELEC 282 IT 274 CONFERENCE 275 MARKET 277 ASST 279 1 1 1 1 AC GFI AC GFI AC GFI AC AC AC AC AC GFI MW GFI REF 2 3 GFI EWC 4 4 AED CLG CLG 5 +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12" +12"+12" +12" +12" +12" 6 7 7 +12" +12"+12" +12" +12"+12" +12" +12"+12" +12" +12"+12" +12"+12" +12"+12" +12" +12"+12" COPIER +12" +12" +12" +12" +12" +12" AC LP2B-32LP2B-27 LP2B-28 LP2B-33 LP2B-34LP2B-29 LP2B-30 LP2B-35 LP2B-31 LP2B-36 LP2B-15 LP2B-16 LP2B-17 LP2B-18 LP2B-19 LP2B-20 LP2B-21 LP2B-22 LP2B-23 LP2B-24 LP2B-25 LP2B-26 LP2B-59 LP2B-60 LP2B-65 LP2B-66 LP2B-64 LP2B-63 LP2B-62 LP2B-67 LP2B-61 LP2B-58 LP2B-58 LP2B-58 LP2B-57 LP2B-57 LP2B-57 LP2B-57 LP2B-56 LP2B-57 LP2B-57 LP2B-53 LP2B-54 LP2B-52 LP2B-55 LP2B-51 LP2B-51 LP2B-51 LP2B-41 LP2B-41 LP2B-41 LP2B-51 LP2B-41 LP2B-45 LP2B-41 LP2B-44 LP2B-42 LP2B-43 LP2B-41 LP2B-40 LP2B-40 LP2B-40 LP2B-40 LP2B-39 LP2B-39 LP2B-39LP2B-38 LP2B-38 LP2B-38 LP2B-38LP2B-37 LP2B-37 LP2B-37LP2B-37 LP2B-47 LP2B-47 LP2B-47 LP2B-49 LP2B-46 LP2B-48 LP2B-49 LP2B-49 LP2B-49 LT2B-1 LT2B-1 LT2B-1 LP2B-50 LP2B-50 LP2B-50 LP2B-51 LP2B-58 LP2B-69 LP2B-69 LP2B-69 LP2B-70 LP2B-71 LP2B-71 E103 2 LP2B-58 LP2B-58 LP2B-58888 LP2B-68 LP2B-72 LP2B-72 LP2B-73 AC LP2B-73 AC LP2B-71 LP2B-71 LP2B-71 LP2B-71 LP2B-71 LP2B-71 E103 3 11 LP2B-85 12 LP2B-86 13 LP2B-87 LT2B-2 LT2B-3 LT2B-7 LT2B-6 LT2B-5 LT2B-4 LT2B-8 LT2B-9 LT2B-10 LT2B-11 LT2B-12 LT2B-13 LT2B-14 LT2B-15 LT2B-16 LT2B-17 LT2B-18 LT2B-19 9 9 9 9 9 9 9 'LT2B' 10 10 10 10 10 LP2B-49 'LP2B' 'HM2B' 'HL2B' 'RP2A' 'T2B' 'TBT' SUSPENDED AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 As indicated 10 / 3 1 / 2 0 1 6 1 1 : 1 6 : 2 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL POWER PLAN - UPPER LEVEL - NORTH E103 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O GENERAL NOTES A NORTH 1/8" = 1'-0"1 UPPER LEVEL POWER PLAN - NORTH KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 PROVIDE 120V, 20A POWER CONNECTION TO FORWARD FOLDING MOTORIZED ADJUSTABLE HEIGHT BASKETBALL GOAL. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATION WITH APPROVED MANUFACTURERS SUBMITTALS PRIOR TO ROUGH-IN. 2 120V, 20A POWER CONNECTION TO GYMNASIUM DIVIDER CURTAIN SYSTEM OPERATOR. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATION WITH APPROVED MANUFACTURERS SUBMITTALS PRIOR TO ROUGH-IN. 3 JUNCTION BOX MOUNTED ABOVE CEILING FOR 120V, 20A POWER CONNECTION TO CEILING MOUNTED MOTORIZED PROJECTION SCREEN OPERATOR. EC SHALL COORDINATE EXACT LOCATION/CONTROL/CONNECTION REQUIREMENTS WITH APPROVED AV DRAWINGS PRIOR TO ROUGH IN. 4 PROVIDE 120V, 20A POWER CONNECTION TO FORWARD FOLDING MOTORIZED BASKETBALL GOAL. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATION WITH APPROVED MANUFACTURERS SUBMITTALS PRIOR TO ROUGH-IN. 5 120V DUPLEX AND DATA RECEPTACLES MOUNTED FLUSH IN CEILING FOR PROJECTOR POWER AND LOW VOLTAGE CABLING CONNECTIONS. EC SHALL COORDINATE EXACT REQUIREMENTS WITH APPROVED AV DRAWINGS PRIOR TO ROUGH-IN. 6 PROVIDE POWER CONNECTION TO LAP TIMER. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATION WITH APPROVED MANUFACTURERS SUBMITTALS PRIOR TO ROUGH-IN. 7 PROVIDE POWER CONNECTION FOR MOTORIZED VOLLEYBALL SLEEVES. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATION WITH APPROVED MANUFACTURERS SUBMITTALS PRIOR TO ROUGH-IN. 8 MOUNT RECEPTACLES HORIZONTALLY UNDER MIRROR. 9 PROVIDE NEMA 5-30R TWISTLOCK RECEPTACLE. SUSPENDED PENDANT MOUNT ABOVE RACK LOCATION ADJACENT TO OVERHEAD CABLE TRAY. FIELD COORDINATE EXACT FINAL LOCATION WITH STRUCTURED CABLING INSTALLER. 10 PROVIDE NEMA 5-20R QUAD RECEPTACLE SUSPENDED PENDANT MOUNT ABOVE RACK LOCATION ADJACENT TO OVERHEAD CABLE TRAY. FIELD COORDINATE EXACT FINAL LOCATION WITH STRUCTURED CABLING INSTALLER. 11 JUNCTION BOX LOCATED ABOVE ACCESSIBLE CEILING PLANE FOR 120V POWER CONNECTION TO VAV CONTROLS TRANSFORMER. EC SHALL COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 12 JUNCTION BOX LOCATED ABOVE ACCESSIBLE CEILING FOR 120V POWER CONNECTION TO FIRE SMOKE DAMPER. EC SHALL COORDINATE EXACT LOCATION AND FIRE ALARM SYSTEM CONNECTION REQUIREMENTS WITH APPROVED MECHANICAL SHOP DRAWINGS PRIOR TO ROUGH-IN. 13 IRRIGATION CONTROLLER, PROVIDE 120V CONNECTION. EC SHALL FIELD COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. EC SHALL REFER TO AUDIO VISUAL AND SECURITY SYSTEMS DRAWINGS FOR ADDITIONAL EC PROVIDED AND INSTALLED CONDUIT, WIRING, AND CIRCUITING. 1/4" = 1'-0"2 ENLARGED LAN ROOM 276 1/4" = 1'-0"3 UPPER LEVEL NORTH ELEC ROOM J J J J J J J J J J J CLG J CLG GWH 1 PP 1 CUH 1 CUH 2 UH 2 CF 3 EF 3 TF 3 UH 3 B 1 B 2 CP 1 CP 2 P 1 P 2 TT J J J J J SS S S S S S S WN A WN A WN A WN A WN A WN A WN A WN A WN A WN A GWH 2 GWH 3 B 3 CP 3 J J CLG JJ ECH 3 WN A WN A S J CF 4A CF 5A J J J J J J J S S S J J J JJ E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EA EB EC ED EE EF 2 Q 9 10 EG EH 1 L P M 3 4 6 7 A4 A5 8 M.6 AH N 7.96.4 NJ 5 GFI +42" GFI +42" GFI AC GFI GFI GFI AC GFI AC GFI AC GFI GFI WP AC GFI GFI AC GFI GFI WP GFI WP GFI WP ACTIVITY POOL 001 POOL MECH 253 POOL STORAGE 255 POOL OFFICE 256 CIRC 259 W. LOCKERS 221 M. LOCKERS 231 JAN 229 ACR3 216 CHG 215ACR2 214 FAM CHANGING 212 ACR1 213 W. TOILETS 223 W. SHOWERS 222 M. TOILETS 233 M. SHOWERS 232 MECHANICAL A102 FOYER A101EXIST LAUNDRY A111 EXIST ELEC A113 EXIST POOL MECH A112 EXIST POOL EQUIP A114 EXIST NATATORIUM A110 POOL STORAGE A108 M. TEAM LOCKER A107 W. TEAM LOCKERS A106 EXIST POOL DECK A109 EXIST POOL DECK A109 PARTY 211 VESTIBULE 201 LOBBY 202 INDOOR PLAY 205 GFI GFI GFI GFIGFI GFI GFI GFI GFI GFI GFIGFI GFI GFI GFI GFI GFI GFI TP TP TP TP TP 'FAA' 1 1 2 3 4 5 5 5 6 TP ELEC 254 KID WATCH 288 KIDS T 207 OFFICE 206 EXIST CHEM A115 ALT WATER SLIDE 002 E106 1 GUARDS 258 GUARD CHG 257+42" GFI GFI WP 'MSD' '(E) L2' '(E) H2' '(E) H1' '(E) L1' '(E) TL1' 'TL2' '(E) BUSSED GUTTER' (E)(E) AC GFI AC GFI AC GFI AC GFI AC GFI GD AC GFI MW AC GFI GFI REF AC GFI TP GFI WP GFI WP GFI WP GFI WP AC GFI 7 5 GFI REF AC GFI MW GFI EWC AC GFI 5 5 AC GFI GFI EWC 4 4 4 TP TP +78" +78" 8 AED WP 9999 10 11 11 11 AMENITY PUMP #1 AMENITY PUMP #2 CURRENT PUMP #1 AND #2 12SLIDE PUMP VESTIBULE A104 STORAGE A105 POOL MECH 253 13 14 15 16 GFI LP2B-70 LP2B-70 LP2A-26 LP2A-26 LP2A-25 LP2A-27 LP2A-28 LP2A-31 LP2A-31 LP2A-29 LP2A-30 LP2A-31 LP2A-31 LP2A-32 LP2A-32 LP2A-32 LP2A-32 LP2B-75 LP2A-36 LP2A-36 LP2A-36 LP2A-32 LP2A-33 LP2A-33 LP2A-33 LP2A-33 LP2A-37 LP2A-37 LP2A-37 LP2A-37 LP2A-37 LP2A-36 LP2A-36 LP2A-37 LP2A-48,50 LP2A-41 LP2A-43 LP2A-43 LP2A-44 LP2A-44 LP2A-45 LP2A-45 LP2A-38,40 LP2A-57 LP2A-45 LP2A-58 LP2A-45 LP2A-45 LP2A-54 LP2A-52 LP2A-55 LP2A-56 LP2A-54 LP2A-47,49 LP2A-56 LP2B-76 LP2B-77 LP2B-77LP2B-78LP2B-77 LP2B-77 LP2B-77 LP2A-56 LP2A-56 LP2A-56 LP2A-63 LP2A-51,53 LP2A-64 LP2A-63 LP2A-61 LP2A-62 LP2A-59 LP2A-59 LP2A-59 LP2A-59 LP2A-59 LP2A-63 LP2A-59 LP2A-64 LP2A-65 LP2A-65 LP2A-65 LP2A-65 LP2A-66 LP2A-66 LP2A-66 LP2A-66 LP2A-66 LP2A-65 1 LP2A-60 10 10 10 10 10 WP WP WP WP WP WP TP LP2A-32 TP LP2A-33 AC GFI TP LP1B-47 LP2B-74 LP2B-74 GFI LP2B-74 GFI LP2B-74 LP2B-75 LP2B-75 LP2B-75 LP2B-75 LP2A-67 GFI LP2A-66 10 LP2A-66 GFI GFI LP2B-74 LP2B-80 LP2B-80 LP2B-79 LP2B-79 LP2B-81 LP2B-80 LP2A-46 LP2A-1217 'VECP' 5 LP2A-39 5 5 18 18 18 19 LP2A-68 LP2A-42 LP2A-70 LP2A-70 LP2A-70 LP2A-72 5 LP2A-74 LP2A-78 20RP2A-13 20 RP2A-13 20 RP2A-13 20 RP2A-13 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 6 : 4 3 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL POWER PLAN - UPPER LEVEL - SOUTH E104 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O GENERAL NOTES A NORTH 1/8" = 1'-0"1 UPPER LEVEL POWER PLAN - SOUTH KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 PROVIDE 120V, 30A/1P RECEPTACLE FOR POOL VACUUM. PROVIDE HINGED WATER-PROOF COVER AND GASKETED FACEPLATE SUITABLE FOR INTENDED USE IN NATATORIUM ENVIRONMENT. CONNECT WITH 2#10, 1#10G, 3/4"C AND PROVIDE GFCI CIRCUIT BREAKER AT PANEL. COORDINATE EXACT CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS AND VERIFY EXACT LOCATION WITH POOL CONTRACTOR AND ARCHITECT PRIOR TO ROUGH-IN. 2 JUNCTION BOX FOR 120V POWER CONNECTION TO MOTORIZED AUTOMATED ACCESS DOOR OPERATOR. EC SHALL MAKE ALL NECESSARY INTERCONNECTIONS BETWEEN JUNCTION BOX, OPERATOR MOTOR, AND PUSH PAD LOCATIONS PER MANUFACTURER'S REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH APPROVED EQUIPMENT SHOP DRAWINGS. 3 JUNCTION BOX FOR 120V POWER CONNECTION TO MOTORIZED AUTOMATED ACCESS DOOR OPERATOR. EC SHALL MAKE ALL NECESSARY INTERCONNECTIONS BETWEEN JUNCTION BOX, SECURITY SYSTEM, OPERATOR MOTOR, AND PUSH PAD LOCATIONS PER MANUFACTURER'S REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH APPROVED EQUIPMENT SHOP DRAWINGS AND SECURITY SYSTEM INSTALLER. 4 WALL MOUNTED JUNCTION BOX FOR 208V, 20A POWER CONNECTION TO HAIR DRYER, COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH-IN. 5 WALL MOUNTED JUNCTION BOX FOR 120V, 20A CONNECTION TO ELECTRIC HAND DRYER. EC SHALL COORDINATE EXACT LOCATION, HEIGHT, AND ELECTRICAL REQUIREMENTS WITH ARCHITECTURAL ELEVATIONS AND APPROVED SHOP DRAWINGS PRIOR TO ROUGH IN. 6 ALL RECEPTACLES LOCATED IN THE CHILDWATCH AREA BELOW 5'-0" SHALL BE TAMPER PROOF. REFER TO DIVISION 26 SPECIFICATIONS FOR MORE INFORMATION. 7 WALL MOUNTED JUNCTION BOX FOR 120V, 20A POWER CONNECTION TO SUIT SPINNER. EC SHALL COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN. 8 LOCATION OF EMERGENCY 'EPO' SWITCHES FOR SHUT DOWN OF POOL PUMP SYSTEMS AS SET FORTH IN POOL ENGINEERING DRAWINGS. 9 WALL MOUNTED RECESSED JUNCTION BOX WITH 3/4"C FOR INSTALLATION OF MOTORIZED ASSIST PUSH PAD DEVICE INSTALLATION. COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN. 10 EC SHALL UTILIZE EXISTING LOCATION FOR NEW SPEAKER STROBE. UTILIZE EXISTING CONDUITS TO AVOID SURFACE MOUNTED CONDUITS. 11 EC SHALL PROVIDE START/STOP SWITCH WITH INTEGRAL INDICATOR LIGHT FOR PUMP INDICATED. DO NOT USE SWITCHES THAT NEED TO BE HELD DOWN TO START THE VFD SLOW START CYCLE; SWITCHES SHOULD OPERATE BY MAKING CONTACT BEFORE THE CYCLE STARTS. ALL FACEPLATES SHALL BE PROVIDED WITH LABEL TO INDICATE THE PUMP CONTROLLED. EC SHALL REFER TO POOL DRAWINGS FOR SCHEMATIC INTERLOCK DIAGRAM. 12 EC SHALL PROVIDE START/STOP SWITCH WITH INTEGRAL INDICATOR LIGHT FOR PUMP INDICATED, PER ALTERNATE #4. ALL FACEPLATES SHALL BE PROVIDED WITH LABEL TO INDICATE THE PUMP CONTROLLED. EC SHALL REFER TO POOL DRAWING 13 PROVIDE 120V, 10A POWER FOR SECURITY SYSTEM DOOR HOLD. REFER TO SECURITY DRAWINGS FOR ADDITIONAL INFORMATION. 14 EPO LOCATION FOR ALTERNATE WATER SLIDE PER ALTERNATE #4. IF ALTERNATE IS ACCEPTED, FIELD COORDIATE EXACT LOCATION. IF ALTERNATE IS NOT ACCECPTED, PROVIDE EMPTY CONDUIT FROM LOCATION INDICATED BACK TO STUB OUT ABOVE ENTRY DOOR WITHIN THE POOL MECHANICAL ROOM. 15 FUTURE SPA EPO LOCATION. PROVIDE JUNCTION BOX AND EMPTY 3/4" CONDUIT FROM LOCATION INDICATED BACK TO STUB OUT ABOVE ENTRY DOOR WITHIN THE POOL MECHANICAL ROOM. 16 FUTURE SPA TIME SWITCH LOCATION. PROVIDE JUNCTION BOX AND EMPTY 3/4" CONDUIT FROM LOCATION INDICATED BACK TO STUB OUT ABOVE ENTRY DOOR WITHIN THE POOL MECHANICAL ROOM. 17 PROVIDE 120V CONNECTION FOR TEMPERATURE CONTROL PANEL. RE: MECHANICAL FOR ADDITIONAL INFORMATION. 18 JUNCTION BOX LOCATED ABOVE CEILING FOR 120V POWER CONNECTION TO FIRE ACCORDIAN DOOR SYSTEM. EC SHALL COORDINATE EXACT LOCATION AND FIRE ALARM SYSTEM CONNECTION REQUIREMENTS WITH APPROVED MANUFACTURER'S SHOP DRAWING PRIOR TO ROUGH-IN. 19 JUNCTION BOX LOCATED ABOVE ACCESSIBLE CEILING PLANE FOR 120V POWER CONNECTION TO VAV CONTROLS TRANSFORMER. EC SHALL COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 20 LOCATION OF FLUSH MOUNTED, CORROSION RESISTANT, JUNCTION BOX LISTED FOR POOL USE, AND LOCATED INSIDE WALL RECESS WITH ACCESS PANEL FOR CONNECTION TO UNDERWATER OF POOL WET NICHE CONDUIT/FIXTURE. JUNCTION BOX SHALL BE LOCATED A MINIMUM OF 18" ABOVE THE ASSOCIATED DECK LEVEL. INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC ARTICLE #680. EC SHALL REFER TO AUDIO VISUAL AND SECURITY SYSTEMS DRAWINGS FOR ADDITIONAL EC PROVIDED AND INSTALLED CONDUIT, WIRING, AND CIRCUITING. EF 9 EF 1 EF 2 EF 4 EF 6 RTU 2 EF 10 EF 12 RTU 1 MAU 1 DSCU 1 RTU 3 PDU 1A EF 5 EF 11 J CLG J CLG J CLG J CLG EF 15 EF 14 PDU 2 EF 17 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EA EB EC ED EE EF 2 A B Q 9 10 EG EH 1 LL P MM 3 4 6 7 A1 A4 AB A5 8 AE AD M.6 AH AC C D E F G K N A2 A3 AG AF AA 6.4 NJ A.1 H J J.3 12 5 5 GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP GFI WP 1 1 GFI WP LP2B-11 2 3 4 5 1 1 LP2B-13 LP2B-12 LP2B-13 LP2B-14 LP2B-13 LP2B-14 LP2B-14 LP2B-14 LP2A-24 LP2A-24 LP2A-22LP2A-24 LP2A-23 LP2A-21 LP2A-23 LP2A-24 LP2A-23LP2A-23 LP2A-24 GFI WP LP2A-24 GFI WP AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/16" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 7 : 0 2 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL ROOF PLAN E105 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NORTH 1/16" = 1'-0"1 ROOF POWER PLAN GENERAL NOTES A EC SHALL REFER TO AUDIO VISUAL AND SECURITY SYSTEMS DRAWINGS FOR ADDITIONAL EC PROVIDED AND INSTALLED CONDUIT, WIRING, AND CIRCUITING. KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 EC SHALL ROUTE HEATTRACE CABLE WITHIN GUTTER FOR LENGTHS AS INDICATED. 2 EC SHALL PROVIDE 120V, 1PH JUNCTION BOX AND HEATTRACE ALONG GUTTER AND DOWNSPPOUTS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS AND LOCATIONS. TOTAL 146 LF RUN INCLUDING DOWNSPOUTS. 1,460 WATTS TOTAL. PROVIDE 2"12, 1#12G, 3/4" C TO JUNCTION BOX. 3 EC SHALL PROVIDE 120V, 1PH JUNCTION BOX AND HEATTRACE ALONG GUTTER AND DOWNSPPOUTS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS AND LOCATIONS. TOTAL 20 LF RUN INCLUDING DOWNSPOUTS. 200 WATTS TOTAL. PROVIDE 2"12, 1#12G, 3/4" C TO JUNCTION BOX. 4 EC SHALL PROVIDE 120V, 1PH JUNCTION BOX AND HEATTRACE ALONG GUTTER AND DOWNSPPOUTS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS AND LOCATIONS. TOTAL 40 LF RUN INCLUDING DOWNSPOUTS. 400 WATTS TOTAL. PROVIDE 2"12, 1#12G, 3/4" C TO JUNCTION BOX. 5 EC SHALL PROVIDE 120V, 1PH JUNCTION BOX AND HEATTRACE ALONG GUTTER AND DOWNSPPOUTS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS AND LOCATIONS. TOTAL 35 LF RUN INCLUDING DOWNSPOUTS. 350 WATTS TOTAL. PROVIDE 2"12, 1#12G, 3/4" C TO JUNCTION BOX. TT SE 1,2 CP 1 CP 2LAP 2 LAP 1 SLCP 1 LCP 1 LH 1 SCP 1 SJP 1SH 1 CCS 2 CCS 1 FC 1 AP 1 CC 2 CH 1 CH 2 J J CC 1 AC 1 SJB 1 FC 2 CCEB 1 CCEB 2 AP 2 J CCBP 1 CCBP 2 T EF 13 KH 1 E3 E4 E5 E6 2 Q EH 1 NJ 'LA2A' 'HA2A' 'HM2A' 'TPA' SUSP 'TAA' PAD MOUNTED 'FACP' 'MDC' GFI POOL MECH 253 ELEC 254 GFI 'MSD' 1 1 GFI GFI GFI 'RP2A' 2 'LP2A' LA2A-14 LA2A-13 LA2A-13 LA2A-13 LA2A-10 LA2A-10 LA2A-13 LA2A-13 LP2A-1LP2A-2 COMMUNITY KITCHEN 142 'T1K' SUSPENDED 'LK1B' LK1B-17 AC GFI LK1B-17 AC GFI LK1B-17 GFI LK1B-16 AC GFI LK1B-15 AC GFI LK1B-14 AC GFI LK1B-13 GFI REF LK1B-12 GFI REFLK1B-11 AC GFI LK1B-8,10 OVEN 30A/2P LK1B-7,9 RANGE 30A/2P LK1B-6 AC GFI LK1B-5 AC GFI LK1B-4 AC GFI MW LK1B-3 AC GFI LK1B-2 DW 30A/1P LK1B-1 AC GFI DED AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/4" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 7 : 0 9 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL ENLARGED POWER PLANS E106 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1/4" = 1'-0"1 UPPER LEVEL ENLARGED POWER PLAN - POOL MECH GENERAL NOTES A KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 PROVIDE 120V, 20-AMP POWER CONNECTION FOR AUTO-FILL CONTROLLER. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH POOL CONTRACTOR PRIOR TO ROUGH-IN. LOW-VOLTAGE WIRING AND CONNECTIONS SHALL BE BY POOL CONTRACTOR. COORDINATE ALL CONDUIT ROUTING AS REQUIRED. 2 PROVIDE 120V CONNECTION FOR SE-1 AND SE-2 CONTROL PANEL. COORDINATE EXACT LOCATION AND POWER REQUIREMENTS WITH APPROVED PLUMBING PLANS. RE: PLUMBING FOR ADDITIONAL INFORMATION. EC SHALL REFER TO AUDIO VISUAL AND SECURITY SYSTEMS DRAWINGS FOR ADDITIONAL EC PROVIDED AND INSTALLED CONDUIT, WIRING, AND CIRCUITING. 1/4" = 1'-0"2 LOWER LEVEl COMMUNITY KITCHEN ENLARGED VIEW DN DN VS S OSC 3 3 VS S OSC 33 VS S VS S D OSC OSC D D D OSC K K OSC OSC VS S 3 VS S VS S WS 2 T RC D D O SC 3 3 3 VS S D RC RC 3 3 OSC RC W S3 WS4 W S5 TS1 TS1 TS1 RC RC RC OSC OSC OSC OSC OS C O SC A B 9 10 L 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K A2 A3 AG AF AA 7.96.4 A.1 B.7 H J J.3 12 5 MP GROUP EX 124 STRENGTH 123 HITTING 122 JR GOLF 121 STAIR 120 RECV & STOR 115 ELEV 117 MEN 110 WOMEN 111 P&R DIRECTOR 108 ELEC 109 STAFF 107 GAMES 106 GYM 131 WOMEN 104 MEN 105 LOUNGE 102 VEST 101 KITCHEN 112 CLASSROOM 114 STOR 113 COMMUNITY 141 STORAGE 143 EMP ENTRY 103 EXIT STAIR S10 GYM STORAGE 132 COMMUNITY KITCHEN 142 STORAGE 118 D1EM D1EM F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 R2 L2 R2 R2 R1 R1 R1 R1 F1 F1 D1 D1EM D1 D1 D1 D1EM D1 D1 F1 F1 F1 F1 F1 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1 RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1EM RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 D1EM RP1B-6 D1 RP1B-6 bD1 bD1 bD1 bD1 aL1A cT1 cT1 aL1B aL1A aL1BaL1B aL1A R22 RP1B-5 R22EM RP1B-5 R22 RP1B-5 R22EM RP1B-5 R22 RP1B-5 P3 RP1B-5 P3 RP1B-5 P3EM RP1B-5 P3 RP1B-5 P3EM RP1B-5 R22EM RP1B-5 R22EM RP1B-5 P3 RP1B-5 P3 RP1B-5 P3EM RP1B-5 P3 RP1B-5 P3 RP1B-5 R9 R9 R9 P1 RP1B-1 P1EM RP1B-1 P1 RP1B-1 P1EM RP1B-1 D1 RP1B-1 D1 RP1B-1 D1EM RP1B-1 D1 RP1B-1 R1 R1R1 R1 R1 W3EM RP2B-12 X1 X1 X2 X2 X1 X1 X1 P1 P1 P1 P1 X1 X2 P5 RP1B-3 P5 RP1B-3 P5 RP1B-3 P5 RP1B-3 P5 RP1B-3 D1 RP1B-1 D1EM RP1B-1 D1 RP1B-1D1 RP1B-1 X1 L2 W1W1 P6 RP1B-1 P6 RP1B-1 P6 RP1B-1 D1 D1 RG1 W2 W2 W2 W2 RG10 RG14 RG8 RG14 R2 R2 P1 P1 P1 P1 P6 RP1B-1 P6 RP1B-1 P6 RP1B-1 P6 RP1B-1 P6 RP1B-1 P1 RP1B-1 P1EM RP1B-1 11'-6" AFF P1 RP1B-1 P1 RP1B-1 P1EM RP1B-1 P1 RP1B-1 P6 RP1B-1 P6 RP1B-1 P1EM RP1B-1 P1 RP1B-1 P1EM RP1B-1 D1 RP1B-1 C1 RP1B-4 C1 RM1 RP1B-2 RM2 RP1B-2 RM2 RP1B-2 RM2 RP1B-2 RM1 RP1B-2 R1 D1 RP1B-1 D1EM RP2B-12 P1 RP2B-12 P1EM RP2B-12 EW3EM RP1B-7 9'-6" EW3EM RP1B-7 9'-6" UC1 D1EM RP1B-1 D1 RP1B-1 D1 RP1B-1 aD1 aD1 aD1 aD1 aD1 bD1 bD1 bD1 bD1 bD1 F1 C2 j C3 f C4 c P8 eD5 d D5EM d D5 d D5 a D5 a D5EM a D5 a D5 a D5 a D5 a D5EM a D5 a D5 a P9 b P9 b D2 d D2 d D2 d D2 a D2 a D2 a D5 g D5EM g D5 g D6 g D6EM g D6 g D6 g D6 g D6 g D2 g D2 g D2 g R9 R9 R9 R9 R9 R9 D1 X1 X1 X1F1 EST1 RP1B-7 EST1 RP1B-7 EST1 RP1B-7 EST1 RP1B-7 EP1 EP1 EP1EM EP1 EP1EM EP1 P1EM RP1B-1 P1EM RP1B-1 L4 RP1B-1 L4 RP1B-1 EW3EM RP1B-7 EW2 RP1B-7 F1 HL1B- 12 a HL1B- 12 bHL1B- 14 a HL1B- 14 b HL1B- 14 c RCD3 a,b,c a,b F1 VSC1 RCD1 VSC2 VSC1 RCD1 VS1 (TYP.) VSC1 OSC2 OSC2 LVKS (TYP.) RCD4 RCD4 RCD4 VSC4 VSC4 VSC4 TS RCD2 VSC1 D1EM RP1B-1 D1EM RP1B-5 D1 RP1B-5 D1 RP1B-5 D1 RP1B-5 P9 h P9 h HL1B- 8 HL1B- 8 HL1B- 8 HL1B- 8 HL1B- 10 HL1B- 10 HL1B- 10 HL1B- 11 HL1B- 11 HL1B- 11 HL1B- 11 HL1B- 11 LP1B- 77 LP1B- 77 LP1B- 77 LP1B- 77 HL1B- 12 HL1B- 12 HL1B- 14 VSC1 VSC1 HL1B- 11 D5 d D5 d D5 d D5 d D5EM d D5 d D5 d D5 g D5 g D5 g D5 g D5EM g D5 g D5 g D6 d D6EM d D6 d D6 d D6 a D6EM a D6 a D6 a D6 a D6 a a,b,c d,e,f g,h,j EW3EM RP1B-7 9'-6" P3 RP1B-5 P3EM RP1B-5 P3 RP1B-5 DAYLIGHT ZONE 63W DAYLIGHT ZONE 63W DAYLIGHT ZONE 42W DAYLIGHT ZONE 42W DAYLIGHT ZONE 132W DAYLIGHT ZONE 111W DAYLIGHT ZONE 30W bD1 D1 D1 VSC2 LP1B- 75 VSC2 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 7 : 2 7 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL LIGHTING PLAN - LOWER LEVEL E112 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O GENERAL NOTES A ALL FIXTURES WITH HATCHING AND/OR DESIGNATED AS 'EM' SHALL BE PROVIDED WITH INTEGRAL BATTERY BACKUP. BATTERY SHALL ENGAGE ONLY AFTER COMPLETE LOSS OF POWER TO THE CIRCUIT. B CIRCUIT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO NEAREST LINE VOLTAGE CIRCUIT, AHEAD OF ALL SWITCH LEGS. UNLESS OTHERWISE NOTED, ALL CIRCUIT NUMBER INDICATED ON THIS SHEET SHALL REFER TO CIRCUIT ORIGINATING IN PANELBOARDS OR RELAY PANELS BASED ON THE FOLLOWING CONVENTION, (THIS SHEET ONLY): TBD-# = CIRCUIT TO 'TBD' C REFER TO LIGHTING CONTROLS SCHEDULES AND DIAGRAMS, SHEET E402 & E403, FOR MORE INFORMATION. D KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1/8" = 1'-0"1 LOWER LEVEL LIGHTING PLAN VS S VS S VS S VS S VS S VS S O SC VS S VS S T DD VS S K K O SC O SC OSC D VS S VS S RC RC WS1 WS6 O SC A B 9 10 L 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K A2 A3 AG AF 7.96.4 A.1 B.7 H J J.3 5 M/P GROUP EX 262 ST. 263 CARDIO 261 LOBBY 202 MEN 203 WOMEN 204 DESK STAFF 272 IT 274 LAN 276 ELEC 282 COPY 278 WATER & FIRE ENTRY 273 CONFERENCE 275 MARKET 277 ASST 279 EXEC DIR 281 HR 283 FACILITY DIR 285 FINANCE 287 TEMP 284 EXIT STAIR S10 bD1 bD1 bD1 aL2 bD1 bD1 bD1 bD1 F1 F1 F1 R1 R1 R1 R1 R9 R9 R1 R1 D4 RP2B-2 D1EM RP2B-2 R2EM RP2B-1 R2 RP2B-1 R2EM RP2B-1 R2 RP2B-1 R2EM RP2B-1 R2 RP2B-1 R2EM RP2B-1 R2 RP2B-1 R2 RP2B-1 D1 D1EM D1 D1EM D1 H1EM RP2B-7 H1 RP2B-6 H1 RP2B-6 H1 RP2B-6 H1 RP2B-6 H1EM RP2B-7 H1 RP2B-6 H1 RP2B-6 H1 RP2B-6 H1EM RP2B-7 H1EM RP2B-9 H1 RP2B-8 H1 RP2B-8 H1EM RP2B-9 H1EM RP2B-9 H1 RP2B-8 H1 RP2B-8 H1 RP2B-8 H1 RP2B-8 H1 RP2B-8 R9 F1 R2 R2 R2 R2 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3EM RP2B-5 P3 RP2B-5 P3 RP2B-5 P3 RP2B-5 W3EM RP2B-12 W3EM RP2B-12 X1 X1 X1 X1 D1 R9 D1 RP2B-2 D1 RP2B-2 D1 RP2B-2 D1EM RP2B-2 D1 RP2B-2 D1 RP2B-2 P1EM RP2B-12 P1 RP2B-12 R20EM RP2B-10 R20 RP2B-10 R20 RP2B-10 RG8 RG8 RG6 RG6 W2 P5 RP2B-3 P5 RP2B-3P5 RP2B-3 C1 P1EM RP2B-2 P1 RP2B-2 P1 RP2B-2 R16A R16A R13A R13A R16A R20 R20 R15A R15EM RP2B-10 W2 UC1 P1 RP2B-5 X1 ST. 263a a b CF1 R13A CF1 CF1 CF1 1 a,b VSC1 RCD1 LVKS (TYP.) RCD2 VSC2 VS1 (TYP.) TS OSC2 OSC2 VSC1 a,bHL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 HL2B- 2 LP2B- 3 LP2B- 3 LVD1 (TYP.) HL2B- 12 HL2B- 12 HL2B- 12 DAYLIGHT ZONE 59W DAYLIGHT ZONE 59W DAYLIGHT ZONE 59W DAYLIGHT ZONE 45W DAYLIGHT ZONE 50W DAYLIGHT ZONE 100W DAYLIGHT ZONE 50W DAYLIGHT ZONE 50W DAYLIGHT ZONE 50W T2 RP2B-13 T2 RP2B-13 LP2B- 5 LP1B-75 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 7 : 4 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL LIGHTING PLAN - UPPER LEVEL - NORTH E113 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1/8" = 1'-0"1 UPPER LEVEL LIGHTING PLAN - NORTH GENERAL NOTES A ALL FIXTURES WITH HATCHING AND/OR DESIGNATED AS 'EM' SHALL BE PROVIDED WITH INTEGRAL BATTERY BACKUP. BATTERY SHALL ENGAGE ONLY AFTER COMPLETE LOSS OF POWER TO THE CIRCUIT. B CIRCUIT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO NEAREST LINE VOLTAGE CIRCUIT, AHEAD OF ALL SWITCH LEGS. UNLESS OTHERWISE NOTED, ALL CIRCUIT NUMBER INDICATED ON THIS SHEET SHALL REFER TO CIRCUIT ORIGINATING IN PANELBOARDS OR RELAY PANELS BASED ON THE FOLLOWING CONVENTION, (THIS SHEET ONLY): TBD-# = CIRCUIT TO 'TBD' C REFER TO LIGHTING CONTROLS SCHEDULES AND DIAGRAMS, SHEET E402 & E403, FOR MORE INFORMATION. D KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 SPEED CONTROL FOR FANS IN LOCATION INDICATED. ALL FANS TO BE CONTROLLED SIMULTANEOUSLY. SPEED WALL CONTROLLER SPECIFICATION HAS BEEN PROVIDED AS PART OF THE LIGHTING FIXTURE SPECIFICATION, REFER THE LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 3 OSC OS S OSC 3 3 3 K K K K OSC 3 3 D OSC K K OSC OSC OSC OSC OSC OSC OSC OSC VSS VS S OSC OSC OSC OSC OSC OSC OSCOSC OSC VS S VS S OSC OSC D D D D RC RC PC PC OSC OSC OSC OSC K K WS6 WS 7 RC PC PC E14 EB EC ED EE EF 2 Q 9 10 10 EH 1 L P M 3 4 6 7 A4 A5 8 M.6 AH N 7.96.4 NJ 5 EW3EM EW3EM EW3EM RP2A-12 EW2 RP2A-11EW3EM RP2A-12 EW3EM RP2A-12 KID WATCH 288 INDOOR PLAY 205 OFFICE 206 KIDS T 207 JAN 229 M. TOILETS 233 W. SHOWERS 222 W. TOILETS 223 ACR3 216CHG 215 ACR2 214 FAM CHANGING 212 ACR1 213 PARTY 211 LOBBY 202 VESTIBULE 201 CIRC 259 W. LOCKERS 221 GUARDS 258 POOL OFFICE 256 GUARD CHG 257POOL STORAGE 255 POOL MECH 253 ELEC 254 EXIST CHEM A115 EXIST POOL EQUIP A114 EXIST POOL MECH A112 EXIST LAUNDRY A111 EXIST ELEC A113 FOYER A101 MECHANICAL A102 M. SHOWERS 232 POOL STORAGE A108 EXIST NATATORIUM A110 EXIST POOL DECK A109 W. TEAM LOCKERS A106 M. TEAM LOCKER A107 ACTIVITY POOL 001 ISLAND 265 ALT WATER SLIDE 002 M. LOCKERS 231 R1 R1 R1 R1D3 D1 D1 W1 W4 RP2A-10 W4 RP2A-10 W4 RP2A-10 F3 bR2 bR2 bR2bR2 bR2 bR2 aP4 aP4 aP4 aP4 aP4 aP4 aP4 aP4 aP4 aP4 R6R8 R5 R3 R4 R7 R4 R6 R5 F1 F1 F1 W4 RP2A-10 W4 RP2A-10 W4 RP2A-10 D3 D3D3D3 H2 b H2EM RP2A-2 H2 RP2A-2 H2 RP2A-2 H2 RP2A-2 H2EM RP2A-2 H2 RP2A-2 H2 RP2A-1 H2 RP2A-1 H2 RP2A-1 H2EM RP2A-1 H2 RP2A-1 H2 RP2A-1H2 a H2 b H2EM RP2A-3 H2 RP2A-3 H2 RP2A-3 H2 a H2 RP2A-2 H2EM RP2A-2 H2 RP2A-2 H2 RP2A-2 R14 R12 R13EMR13 R14R12 R13R13EM R13EM R12R14 R13 R13EM R11 R12 R13EM R11 R13EM R13EM R11 R11 R11 R2 RP2B-2 R2 RP2B-2 X1 X1 X1 X1 D3 X1 X1 RG10 RG6 RG4 D1 D1 R1 D1EM X1 D1 D1 D1EM D1EM D1 D1EM D1 X1 D3 D3 D3 D3 D3 D3 D3 D3 D1 D1EM D1 RG87RG15 R12 R12EM RG6 RG6 D3 D3 D1 D1EMD1 D3D1 D1EM RG15 D1 D1EM D1 D1 D1 D1EM 1 1 1 1 1 1 1 P7 RP2B-11 P7 RP2B-11 P7 RP2B-11 P1 RP2B-2 19'-6" P1 RP2B-2 22'-0" P1 RP2B-2 22'-0" P1 RP2B-2 22'-0" P1 RP2B-2 22'-0" P1EM RP2B-2 22'-0" P1EM RP2B-2 21'-0" P1 RP2B-2 21'-0" P1 RP2B-2 21'-0"P1 RP2B-2 21'-0" P1EM RP2B-2 19'-6" P1 RP2B-2 19'-6" P1 RP2B-2 19'-6" P1 RP2B-2 22'-0" P1 RP2B-2 22'-0" D1 RP2B-2 D1 RP2B-2 D1 RP2B-2 D1EM RP2B-2 D1 RP2B-2 D1 RP2B-2 R12EM R14 R12EMR11R11R10 R12 R11 R13EM R11 R13 R10 R11 R10 R11 R12 VESTIBULE A104 EXIST POOL DECK A109 M. LOCKERS 2 A103 RG12 D1EM D1 D1EM D1 D1EM D1EMD3 D3 D3 D3 D1EM D1 D1EM D1 D1EM D1 D3D3 D3D3 R15R14R13EM R12 R12 R11 R10 R13EM R11R11 RG8 RG14 F2 F2 F2 F2 P1 RP2A-10 P1EM RP2A-10 P1 RP2A-10 X1 X1D7EM RP2A-10D7 RP2A-10 D7 RP2A-10 X1 F1 F3 F3 F3 R1 R1 F1 F1 W1 D1 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 RG15 W2 W2 W2 R12 R14 R12EM R16 W2 D3 D1EM W1 W1 D1EM D3 D1 D1 D1EM D3 W1 D1 D1 D1 C1 Y1 Y1 D1 H2 RP2A-2 H2 RP2A-1 H2EM RP2A-1 D7 RP2A-2 D7 RP2A-2 HL2B- 13 a HL2B- 13 b HL2B- 13 a HL2B- 13 b a,b RCD2 RCD1 VS1 (TYP.) LVD1 (TYP.) LVKS (TYP.) VSC1 VSC3 OSC3 OSC2 PC1 OSC3 OSC2 OSC2 OSC2 OSC2 OSC2 OSC2 OSC2 OSC2 OSC2 VSC2 OSC2 OSC2 OSC2 OSC3 VSC2 VSC1 D1 RP2B-2 D1 RP2B-2 D1 RP2B-2 HL2B- 13 LP2A- 35 HL2B- 18 LP2A- 35 LP2A- 35LP2A- 77 LP2A- 77 LP2A- 77 LP2A- 77 LP2A- 77 X1 X1 X1 a,b RCD2 HL2B- 17 D1 EW2EM RP2A-11 EW2 RP2A-11 EW3EM DAYLIGHT ZONE 356W DAYLIGHT ZONE 356W DAYLIGHT ZONE 31W DAYLIGHT ZONE 45W DAYLIGHT ZONE 30W Y1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1D1 EW3EM 2 2 LVKS LP2A- 79 LP2A- 79 HL2B- 18HL2B- 18HL2B- 18 HL2B- 18 HL2B- 18 LP2A- 77 F3 F3 F3F3F3F3F3 2 3 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 8 : 5 4 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL LIGHTING PLAN - UPPER LEVEL - SOUTH E114 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1/8" = 1'-0"1 UPPER LEVEL LIGHTING PLAN - SOUTH GENERAL NOTES A ALL FIXTURES WITH HATCHING AND/OR DESIGNATED AS 'EM' SHALL BE PROVIDED WITH INTEGRAL BATTERY BACKUP. BATTERY SHALL ENGAGE ONLY AFTER COMPLETE LOSS OF POWER TO THE CIRCUIT. B CIRCUIT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO NEAREST LINE VOLTAGE CIRCUIT, AHEAD OF ALL SWITCH LEGS. UNLESS OTHERWISE NOTED, ALL CIRCUIT NUMBER INDICATED ON THIS SHEET SHALL REFER TO CIRCUIT ORIGINATING IN PANELBOARDS OR RELAY PANELS BASED ON THE FOLLOWING CONVENTION, (THIS SHEET ONLY): TBD-# = CIRCUIT TO 'TBD' C REFER TO LIGHTING CONTROLS SCHEDULES AND DIAGRAMS, SHEET E402 & E403, FOR MORE INFORMATION. D KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 NO NEW WORK IN THIS AREA. EXISTING LIGHTING AND CONTROLS TO REMAIN. 2 EXISTING LIGHT TO BE REPLACED WITH NEW FIXTURE TYPE INDICATED, UTILIZE EXISTING WIRING AND CONTROLS. 3 LIGHTING ROOM CONTROLLER TO BE NETWORKED TO CENTRAL LIGHTING CONTROL SYSTEM RELAY PANEL TO ALLOW ALL CONTROLLER RELAYS/ZONES TO BE CONTROLLED WITH NATATORIUM LIGHTING (RELAY RP1A-3) VIA WALLSTATION CONTROLS AND AUTOMATIC TIME-CLOCK. POINT F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 F35 F36 F37 F38 F39 F40 LOCATION DESCRIPTION UTILITY XFMR MSD MDC (E)PEU (E)H1 (E)TL1 PRI (E)TL1 SEC (E)L1 (E)H2 (E)TL2 PRI (E)TL2 SEC (E)L2 HA2A TAA PRI TAA SEC LA2A TPA PRI TPA SEC LP2A HM2A HM2B HL2B T2B PRI T2B SEC LP2B TBT PRI TBT SEC LT2B RTU 1 RTU 2 RTU 3 ELEV 1 HM1B HL1B T1B PRI T1B SEC LP1B T1K PRI T1K SEC LK1B LENGTH (L) (ft) 130 15 170 85 5 0 5 85 5 0 5 5 10 0 18 10 0 22 20 260 250 15 0 5 28 0 10 180 160 165 225 285 300 10 0 5 20 0 5 VOLTAGE (EL-L) 480 480 480 480 480 208 208 480 480 208 208 480 480 208 208 480 208 208 480 480 480 480 208 208 480 208 208 480 480 480 480 480 480 480 208 208 480 208 208 VOLTAGE (EL-N) -- 277 277 277 277 277 120 120 277 277 120 120 277 277 120 120 277 120 120 277 277 277 277 120 120 277 120 120 277 277 277 277 277 277 277 120 120 277 120 120 PHASE 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 WIRE SIZE 500 500 2X 2X 6 1 1 1 6 1 1 3X 4 1X 1X 1 250 250 3X 4X 3X 2X 3X 3X 4 1X 1X 1X 2 2X 1X 4X 3X 2X 3X 3X 4 1X 1X CONDUCTOR MATERIAL COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER COPPER CONDUCTOR TYPE THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS THREE SINGLE CONDUCTORS CONDUIT MATERIAL NONMAGNETIC STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL VOLTAGE CLASS 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V C VALUE -- 26706 22185 10755 10755 2425 7292 7292 7292 2425 7292 7292 12843 3806 8924 8924 7292 16483 16483 12843 15082 12843 10755 12843 12843 3806 8924 8924 8924 5906 10755 8924 15082 12843 10755 12843 12843 3806 8924 8924 # OF PARALLEL RUNS -- 7 7 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 2 1 2 2 1 1 1 1 1 1 1 1 2 1 2 2 1 1 1 Isc AVAILABLE UPSTREAM -- 45,200 40,596 40,029 40,029 18,692 16,410 16,410 40,029 14,916 13,426 13,426 40,029 38,935 28,438 28,438 40,029 33,411 33,411 40,029 40,029 40,029 11,470 10,844 10,844 11,470 8,793 8,793 40,029 40,029 40,029 40,029 40,029 40,029 10,733 10,360 10,360 10,733 8,918 8,918 f L-L -- 0.11 0.01 2.28 1.14 0.14 0.00 0.09 1.68 0.11 0.00 0.08 0.03 0.37 0.00 0.48 0.20 0.00 0.37 0.11 2.49 1.41 0.06 0.00 0.02 0.30 0.00 0.08 2.91 3.91 2.22 3.64 2.73 1.69 0.04 0.00 0.02 0.20 0.00 0.04 M L-L -- 0.90 0.99 0.30 0.47 0.88 1.00 0.91 0.37 0.90 1.00 0.93 0.97 0.73 1.00 0.68 0.83 1.00 0.73 0.90 0.29 0.42 0.95 1.00 0.98 0.77 1.00 0.92 0.26 0.20 0.31 0.22 0.27 0.37 0.97 1.00 0.98 0.83 1.00 0.96 Isc AT EQUIP (I3ph) OR (IL-L) 45,200 40,596 40,029 12,193 18,692 16,410 16,410 15,004 14,916 13,426 13,426 12,470 38,935 28,438 28,438 19,245 33,411 33,411 24,364 35,983 11,470 16,639 10,844 10,844 10,656 8,793 8,793 8,126 10,229 8,148 12,447 8,624 10,733 14,898 10,360 10,360 10,189 8,918 8,918 8,562 POINT F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 F35 F36 F37 F38 F39 F40 FAULT CURRENT CALCULATION SCHEDULE T X0 X1 2000N TO UTILITY PLATTE RIVER POWER AUTHORITY (PRPA) PAD MOUNTED UTILITY 2000 KVA TRANSFORMER (ACTUAL SIZE BASED UPON UTILITY DISCRESION) 277/480V, 3 PH, 4W MAIN DISTRIBUTION CENTER (MDC) 2000A, 277/480V, 3PH, 4-WIRE, NEMA 1, 65KAIC RATED M GFP 2000A/3P LSIG RE:2/E400 N G PRPA UTILITY NEMA 3R CONNECTION CT CABINET & MAIN SERVICE DISCONNECT (MSD) 2000NG SPD 10 0 A / 3 P PANEL 'HM2B' 225NG X21 T XFMR XFMR PANEL 'LP2B' 'T2B' 112.5KVA X25 X23 X24 22 5 A / 3 P X2 (E) PANEL 'H1' 17 5 A / 3 P UPPER LEVEL (E) PEU RTU 1 12 5 A / 3 P MECH RTU 2 90 A / 3 P MECH 25 0 A / 3 P SP A C E 10 0 A / 3 P SP A C E EX T E R I O R RE C R E A T I O N B U I L D I N G IN T E R I O R T XFMR XFMR PANEL 'LA2A' 'TAA' 30KVA X15 X13 X14 22 5 A / 3 P SP A R E 1 GRADE PRPA ENERGY METER T (E) (E) (E) PANEL 'L1' 'TL1' 30KVA X7 X5 X6 (E) PANEL 'H2' 10 0 A / 3 P T (E) (E) (E) PANEL 'L2' 'TL2' 30KVA X11 X9 X10 17 5 A / 3 P 175NG 175NG 100NG PANEL 'HA2A' 225NG X12 22 5 A / 3 P PANEL 'HM2A' 225NG X19 22 5 A / 3 P PANEL 'HL2B' 400NG X22 22 5 A / 3 P PANEL 'HM1B' 225NG T XFMR XFMR PANEL 'LP1B' 'T1B' 112.5KVA X37 X35 X36 40 0 A / 3 P 10 0 A / 3 P PANEL 'HL1B' 100NG T XFMR XFMR PANEL 'LK1B' 'T1K' 30KVA X40 X38 X39 LOWER LEVEL T XFMR XFMR PANEL 'LP2A' 12 5 A / 3 P 'TPA' 75KVA X18 X16 X17 1" CONDUIT T XFMR XFMR PANEL 'LT2B' 'TBT' 30KVA X28 X26 X27 2 2 RTU 3 17 5 A / 3 P MECH X3 X4 X8 X29 X30 X31 X33 X34 10 0 A / 3 25 0 A / 3 P SP A C E 10 0 A / 3 P SP A C E ELEV 1 MECH X32 5#1, 2"C FEEDER SCHEDULE KEY/ AMPS SERVICE ENTRANCE FEEDERS 400N 600N 800N 1000N 1200N 1600N 2000N 2500N 3000N 3500N 4000N EQUIPMENT FEEDERS 20NG 30NG 40NG 50NG 60NG 70NG 80NG 90NG 100NG 110NG 125NG 150NG 175NG 200NG 225NG 250NG 300NG 350NG 400NG 450NG 500NG 600NG 700NG 800NG 1000NG 1200NG 1600NG 2000NG GROUNDING CONDUCTORS G8 G6 G4 G2 G10 G20 G30 NOTES: 1. 2. 3. FEEDER CONDUIT AND CONDUCTORS 2[4#3/0, 2"C] 2[4#350, 3"C] 2[4#500, 3-1/2"C] 3[4#400, 3-1/2"C] 4[4#350, 3"C] 5[4#400, 3-1/2"C] 6[4#400, 3-1/2"C] 7[4#500, 3-1/2"C] 8[4#500, 3-1/2"C] 10[4#500, 3-1/2"C] 11[4#500, 3-1/2"C] 4#12, #12G, 3/4"C 4#10, 1#10G, 3/4"C 4#8, 1#10G, 1"C 4#6, 1#10G, 1-1/4"C 4#4, 1#10G, 1-1/4"C 4#4, 1#8G, 1-1/4"C 4#3, 1#8G, 1-1/4"C 4#2, 1#8G, 1-1/2"C 4#1, 1#8G, 1-1/2"C 4#1, 1#6G, 2"C 4#1/0, 1#6G, 2"C 4#1/0, 1#6G, 2"C 4#2/0, 1#6G, 2"C 4#3/0, 1#6G, 2-1/2"C 4#4/0, 1#4G, 2-1/2"C 4#250, 1#4G, 3"C 4#350, 1#4G, 3"C 4#500, 1#3G, 3-1/2"C 2[4#3/0, 1#3G, 2-1/2"C] 2[4#4/0, 1#2G, 2-1/2"C] 2[4#250, 1#2G, 3"C] 2[4#350, 1#1G, 3"C] 2[4#500, 1#1/0G, 3-1/2"C] 2[4#500, 1#1/0G, 3-1/2"C] 3[4#400, 1#2/0G, 3-1/2"C] 4[4#350, 1#3/0G, 3"C] 5[4#400, 1#4/0G, 3-1/2"C] 6[4#400, 1#250G, 3-1/2"C] 1#8, 3/4" C 1#6, 3/4" C 1#4, 3/4" C 1#2, 3/4" C 1-1/0, 3/4" C 1-2/0, 3/4" C 1-3/0, 3/4" C FEEDER FOR SECONDARY OF SEPARATELY DERIVED SYSTEM (SDS). GROUND SIZE PER NEC 250.66. ALL CONDUCTORS ARE SINGLE CONDUCTOR COPPER THWN UNLESS NOTED OTHERWISE. AMPACITY BASED ON NEC TABLE 310.16. ALL CONDUITS ARE EMT UNLESS NOTED OTHERWISE, FILL RATIOS BASED ON NEC ANNEX C TABLE C1. KEY/ AMPS SDS XFMR FEEDERS (NOTE 1) 30S 50S 100S 150S 250S 400S 500S 800S 1000S 1600S 2500S 20G 30G 40G 50G 60G 70G 80G 90G 100G 110G 125G 150G 175G 200G 225G 250G 300G 350G 400G 450G 500G 600G 700G 800G 1000G 1200G 1600G 2000G ABBREVIATIONS MECH XFMR FEEDER CONDUIT AND CONDUCTORS 4#10, 1#8G, 3/4"C 4#6, 1#8G, 1-1/4"C 4#1, 1#6G, 1-1/2"C 4#1/0, 1#6G, 2"C 4#250, 1#2G, 3"C 2[4#3/0, 1#2G, 2"C] 2[4#250, 1#1/0G, 3"C] 2[4#500, 1#2/0G, 3-1/2"C] 3[4#400, 1#4/0G, 3-1/2"C] 5[4#400, 1#350G, 3-1/2"C] 7[4#500, 1#500G, 3-1/2"C] 3#12, #12G, 3/4"C 3#10, 1#10G, 3/4"C 3#8, 1#10G, 1"C 3#6, 1#10G, 1"C 3#4, 1#10G, 1"C 3#4, 1#8G, 1-1/4"C 3#3, 1#8G, 1-1/4"C 3#2, 1#8G, 1-1/4"C 3#1, 1#8G, 1-1/2"C 3#1, 1#6G, 1-1/2"C 3#1/0, 1#6G, 1-1/2"C 3#1/0, 1#6G, 1-1/2"C 3#2/0, 1#6G, 2"C 3#3/0, 1#6G, 2"C 3#4/0, 1#4G, 2"C 3#250, 1#4G, 2-1/2"C 3#350, 1#4G, 2-1/2"C 3#500, 1#3G, 3"C 2[3#3/0, 1#3G, 2"C] 2[3#4/0, 1#2G, 2"C] 2[3#250, 1#2G, 2-1/2"C] 2[3#350, 1#1G, 2-1/2"C] 2[3#500, 1#1/0G, 3"C] 2[3#500, 1#1/0G, 3"C] 3[3#400, 1#2/0G, 3"C] 4[3#350, 1#3/0G, 3"C] 5[3#400, 1#4/0G, 3"C] 6[3#400, 1#250G, 3"C] SEE MECH SCHEDULE SEE XFMR SCHEDULE PANEL HL1A M = MECHANICAL L = LIGHTING P = POWER T = TELECOM A = AQUATICS K = KITCHEN H = 480/277V L = 208/120V A = RISER A B = RISER B # = FLOOR SERVED 1 = LOWER LEVEL 2 = UPPER LEVEL KVA RATING 3 6 9 15 30 45 75 112.5 150 225 300 500 750 PRIMARY FLA 3.6 7.2 10.8 18.1 36.1 54.2 90.3 135.4 180.5 270.8 361.0 601.7 902.5 SECONDARY FLA 8.3 16.7 25.0 41.7 83.3 125.0 208.3 312.5 416.7 625.0 833.3 1388.9 2083.3 PRIMARY PROTECTION 15A/3P 15A/3P 15A/3P 25A/3P 45A/3P 70A/3P 125A/3P 175A/3P 225A/3P 350A/3P 450A/3P 750A/3P 1200A/3P PRIMARY FEEDER 3#12, 1#12G, 3/4"C 3#12, 1#12G, 3/4"C 3#12, 1#12G, 3/4"C 3#10, 1#10G, 3/4"C 3#6, 1#10G, 1"C 3#4, 1#8G, 1-1/4"C 3#1, 1#6G, 1-1/2"C 3#2/0, 1#6G, 2"C 3#4/0, 1#4G, 2"C 3#500MCM, 1#3G, 3"C 2[3#4/0, 1#2G, 2"C] 2[3#500MCM, 1#1/0G, 3"C] 3[3#350MCM, 1#3/0G, 3"C] SECONDARY PROTECTION 15A/3P 20A/3P 30A/3P 50A/3P 100A/3P 150A/3P 250A/3P 400A/3P 500A/3P 800A/3P 1000A/3P 1600A/3P 2500A/3P SECONDARY FEEDER 4#12, 1#8G, 3/4"C 4#12, 1#8G, 3/4"C 4#10, 1#8G, 3/4"C 4#6, 1#8G, 1-1/4"C 4#1, 1#6G, 1-1/2"C 4#1/0, 1#6G, 2"C 4#250MCM, 1#2G, 3"C 2[4#3/0, 1#2G, 2-1/2"C] 2[4#250MCM, 1#1/0G, 3"C] 2[4#500MCM, 1#2/0G, 3-1/2"C] 3[4#400MCM, 1#3/0G, 3-1/2"C] 5[4#400MCM, 1#3/0G, 3-1/2"C] 7[4#500MCM, 1#3/0G, 3-1/2"C] DERIVED GROUND CONDUCTOR 1#8, 3/4"C 1#8, 3/4"C 1#8, 3/4"C 1#8, 3/4"C 1#8, 3/4"C 1#6, 3/4"C 1#2G, 3/4"C 1#1/0G, 3/4"C 1#1/0G, 3/4"C 1#2/0G, 3/4"C 1#3/0G, 3/4" 1#3/0G, 3/4" 1#3/0G, 3/4" APPROX. DIMENSIONS HIGH 15 15 20 28 33 33 37 42 46 48 52 60 74 WIDE 15 15 20 23 24 30 32 36 36 48 48 56 56 DEEP 11 11 15 17 18 20 24 24 24 30 31 36 41 APPROX. WEIGHT 140LBS 145LBS 245LBS 285LBS 369LBS 590LBS 750LBS 1050LBS 1350LBS 2000LBS 2350LBS 3450LBS 3950LBS TRANSFORMER SCHEDULE GROUNDING ELECTRODE SYSTEMS NOTES 1 METAL UNDERGROUND WATER PIPE - MAKE CONNECTION TO METAL UNDERGROUND WATER PIPE INDIRECT CONTRACT WITH THE EARTH FOR 10' OR AND ELECTRICALLY CONTINUOUS TO THE POINTS OF CONNECTION TO THE GROUNDING ELECTRODE CONDUCTOR AND BONDING CONDUCTORS. CONNECTION POINT TO BE AT A MAXIMUM OF 5' OF THE POINT OF ENTRANCE ON THE INTERIOR OF THE BUILDING. 2 BUILDING STEEL - THE METAL FRAME OF THE BUILDING OR STRUCTURE, WHERE ANY OF THE FOLLOWING METHODS ARE USED TO MAKE AN EARTH CONNECTION: A. AT LEAST ONE STRUCTURAL METAL MEMBER THAT IS IN DIRECT CONTACT WITH THE EARTH FOR 10' OR MORE, WITH OR WITHOUT CONCRETE ENCASEMENT. B. HOLD-DOWN BOLTS SECURING THE STRUCTURAL STEEL COLUMN THAT ARE CONNECTED TO A CONCRETE ENCASED ELECTRODE THAT COMPLIES WITH 250.52(A)(3) AND IS LOCATED IN THE SUPPORT FOOTING OR FOUNDATION. THE HOLD-DOWN BOLTS SHALL BE CONNECTED TO THE CONCRETE-ENCASED ELECTRODE BY WELDING, EXOTHERMIC WELDING, THE USUAL STEEL TIE WIRES, OR OTHER APPROVED MEANS. 3 UFER GROUND (CONCRETE-ENCASED ELECTRODE) - AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH EARTH, CONSISTING OF AT LEAST 20' OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2" IN DIAMETER, OR CONSISTING OF AT LEAST 20' OF BARE COPPER CONDUCTOR NOT SMALLER THAN NO. 4 AWG. REINFORCING BARS SHALL BE PERMITTED TO BE BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER EFFECTIVE MEANS. 4 GROUND ROD - ROD IS TO BE 8FT IN LENGTH AND SHALL BE MADE OF IRON OR STEEL AT LEAST 5/8" DIAMETER. INSTALLATION METHODS FOR GROUND ROD SHALL BE IN COMPLIANCE WITH THE NEC SUCH THAT AT LEAST 8' OF LENGTH IS IN CONTACT WITH THE EARTH. GENERAL GROUNDING NOTES 1 ALL CABLES TO BE TERMINATED ONTO BUS BAR WITH TWO HOLE COMPRESSION LUGS AND ATTACHED TO BUS BAR WITH TAB COMPRESSION BELLEVILLE WASHERS AND TORK BOLT ASSEMBLY. 2 ALL GROUND CONNECTORS SHALL BE STRANDED. 3 ALL BUS BARS SHALL BE ATTACHED TO SURFACE WITH NON- CONDUCTIVE STAND-OFFS. 4 GROUND BUS BAR AND GROUNDING SYSTEM SHALL BE UL LISTED AND COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS. PRINCIPAL GROUND POINT (PGP) CU GROUND BAR INTERNAL TO 'MSD' TELECOMMUNICATIONS GROUND BAR ('TMGB-1') IN LAN #276 XFMR INTERNAL GROUND BAR(S) TYPICAL ALL TRANSFORMERS INTERSYSTEM'S BONDING BRIDGE PER NEC 250.94 EXTERNAL TO 'MDC' G20 G20 XFMR G4G30 CWP UFER G30 BLDG STEEL G6 GND ROD AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 NTS 10 / 3 1 / 2 0 1 6 1 1 : 2 5 : 2 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL ONE-LINE DIAGRAM E400 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NTS1ELECTRICAL ONE-LINE DIAGRAM KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 TRANSIENT VOLTAGE SURGE SUPPRESSION UNIT IS TO BE 'LEA INTERNATIONAL' #LSP300-277/480-3Y. REFER TO MANUFACTURER'S SPECIFICATIONS FOR EXACT INSTALLATION INSTRUCTIONS. DO NOT EXCEED MANUFACTURER'S RECOMMENDED LEAD LENGTHS. 2 TRANSFORMER LOCATED REMOTELY FROM PRIMARY DISCONNECTING MEANS. PROVIDE LOCKABLE PRIMARY OVERCURRENT PROTECTION DEVICE AND FIELD MARK LOCATION ON TRANSFORMER PER NEC 450.14. REFER TO UPSTREAM PANEL SCHEDULE FOR MORE INFORMATION. NTS3PANELBOARD NAMING CONVENTION NTS5GROUNDING DIAGRAM (*) EXISTING LOADS TAKEN FROM PREVIOUS ENGINEERING DOCUMENTS DATED 11-2007. THEREFORE THE 2000A SERVICE IS JUSTIFIED. Total Est. Demand:1222 A Total Conn.:1203 A Total Est. Demand:1016 kVA Total Conn. Load:1000 kVA @ 480/277V, 3PH 1203 A TOTAL NEW LOAD 999933 VA FUTURE AQUATICS EQUIP 40 kVA 48 A ELEVATOR 32 kVA 38 A RTU-3 152 kVA 183 A RTU-2 58 kVA 69 A RTU-1 76 kVA 92 A 'HL1B' 7 kVA 9 A 'HM1B' 72 kVA 86 A 'HL2B' 23 kVA 27 A 'HM2B' 92 kVA 111 A 'HM2A' 63 kVA 76 A 'LP2A' (VIA 'TPA') 75 kVA 91 A 'HA2A' 120 kVA 145 A (E) 'H2' (*) 35 kVA 42 A (E) 'H1' (*) 97 kVA 116 A (E) PEU (*) 57 kVA 68 A LOAD DESCRIPTION Load LOAD (AMPS) MAIN DISTIRUBTION CENTER (2500A, 480/277V, 3PH, 4W) LOAD SUMMARY MDC 2ND FLOOR LAN #276 FACP SECURITY FACP ELEV 1 11 KEYNOTE LEGEND 1. NEW (1) 3" PVC CONDUIT ROUTED 30" BELOW GRADE FOR CONNECTION TO SITE TELEPHONE SERVICE POINT. ELECTRICAL CONTRACTOR SHALL VERIFY CONDUIT SIZING AND QUANTITY WITH SERVICE PROVIDER PRIOR TO INSTALLATION. 2. NEW (1) 2" PVC CONDUIT ROUTED 30" BELOW GRADE FOR FUTURE CONNECTION TO SITE FIBER OPTIC SERVICE POINT. ELECTRICAL CONTRACTOR SHALL VERIFY CONDUIT SIZING AND QUANTITY WITH SERVICE PROVIDER PRIOR TO INSTALLATION. 3. NEW (1) 3" PVC CONDUIT ROUTED 30" BELOW GRADE FOR CONNECTION TO SITE CATV SERVICE POINT. ELECTRICAL CONTRACTOR SHALL VERIFY CONDUIT SIZING AND QUANTITY WITH SERVICE PROVIDER PRIOR TO INSTALLATION. 4. MAIN TELEPHONE TERMINAL BOARD 'MTTB' SHALL CONSIST OF 3/4 INCH, FIRE-RETARDANT TREATED PLYWOOD INSTALLED FLOOR TO CEILING IN ROOM, FOR LENGTHS AS INDICATED ON THE PLAN DRAWINGS. ALL RECEPTACLE DEVICES SHOWN IN BACKBOARD ON PLANS SHALL BE FLUSH MOUNT, UON. 5. NEW TYPICAL WORK AREA COMMUNICATIONS OUTLET FOR STRUCTURED CABLE TERMINATIONS. PROVIDE 2-INCH DEEP, 2-GANG BOX WITH 1-GANG PLASTER RING. PROVIDE 1" CONDUIT TO ACCESSIBLE CEILING AND BUSH END. RECEPTACLE FACEPLATE, JACK, CABLING, AND TERMINATIONS BY OTHERS. 6. NEW TYPICAL WORK AREA OUTLET FOR CABLE TV TERMINATION. PROVIDE 2-INCH DEEP, 2-GANG BOX WITH 1-GANG PLASTER RING. PROVIDE 1-1/4" CONDUIT TO ACCESSIBLE CEILING AND BUSH END. CATV RECEPTACLE FACEPLATE, JACK, CABLING, AND TERMINATIONS BY OTHERS. 7. PROVIDE GREEN COPPER GROUNDING CONDUCTOR (TYPICAL) BETWEEN GROUNDING BUSSES AS INDICATED ON GROUNDING DETAIL 5/E400. 8. ROUTE (1) 1/2" CONDUIT FOR FIRE ALARM CONTROL PANEL COMMUNICATIONS CABLING RACEWAY. 9. ROUTE (1) 1/2" CONDUIT FOR SECURITY CONTROL PANEL COMMUNICATIONS CABLING RACEWAY. 10. PROVIDE (1) 3/4"C WITH PULL WIRE TO ELEVATOR CONTROL PANEL FOR ELEVATOR COMMUNICATIONS CABLING RACEWAY. CABLING SHALL BE FURNISHED BY OTHERS. 11. INTERSYSTEM'S GROUNDING BRIDGE (IGB) AS REQUIRED BY NEC 250.94. LOCATED EXTERNAL TO THE MAIN SERVICE GROUND EQUIPMENT. REFER TO 5/E400 FOR GROUNDING ONE-LINE DIAGRAM. 12. TELECOMMUNICATIONS MAIN GROUNDING BAR 'TMGB'. KEY VALUE KEYNOTE TEXT GENERAL NOTES 12 A. PROVIDE EMT FOR ALL CABLING ROUTED THROUGH AREAS WITH EXPOSED STRUCTURAL CEILINGS AND THROUGH INACCESSIBLE CEILINGS. COORDINATE CONDUIT SIZE REQUIREMENTS WITH CABLE INSTALLER. B. ALL EXPOSED CONDUIT SHALL BE CONCEALED TO THE EXTENT POSSIBLE, AND SHALL BE INSTALLED PARALLEL AND CLOSE TO STRUCTURAL MEMBERS. PAINT CONDUIT TO MATCH ADJACENT FINISHES. C. PROVIDE PULLCORD FOR ALL CONDUIT INSTALLED FOR CABLE. D. PROVIDE PULLBOXES AS REQUIRED BY CABLE INSTALLER FOR RUNS EXCEEDING MAXIMUM PULL DISTANCE, AS IDENTIFIED BY CABLE INSTALLER. E. PROVIDE SLEEVES AND CONDUIT BETWEEN FLOORS FOR ROUTING OF CABLE. COORDINATE CONDUIT SIZE WITH CABLE INSTALLER. COORDINATE LOCATION OF RACEWAY WITH ARCHITECT AND CABLE INSTALLER. F. ALL CONDUIT AND CABLING IN CRAWL SPACE IS TO BE SUPPORTED BY AND TIGHT TO STRUCTURE ABOVE. WHERE CONDUIT TRANSITIONS FROM BEING SUPPORTED BY STRUCTURE INTO SOIL, ADD LOOP AND/OR FLEXIBLE CONDUIT FOR FLEXIBILITY AND TO ALLOW FOR ANTICIPATED SOIL MOVEMENT. G. REFER TO SPECIFICATIONS FOR FULL CONDUIT REQUIREMENTS. HOWEVER, NOTE THAT ALL UNDERGROUND CONDUIT BENDS ARE TO BE GALVANIZED RIGID CONDUIT. UNDERGROUND CONDUIT EXTENDING ABOVE SLAB IS ALSO TO BE GALVANIZED RIGID CONDUIT. 3 1 56 56 10 7 2 8 94 8 TSTS TS FS FS TSFS FS MAXIMUM 5'-0" CONTROL BY DIV. 26 DUCT DETECTOR REMOTE TEST STATION BY DIV. 26 BY DIV. 26 PANEL BY DIV. 26 ALARM FIRE DAMPERS PRIOR TO BID. ALL MECHANICAL PLANS NOTIFY ENGINEER OF ANY FOR LOCATIONS OF ALL POWERED RESPONSIBLE FOR REVIEWING ELECTRICAL CONTRACTOR IS RELAY BY DIV. 26 NORMALLY CLOSED WIRING BY DIV. 26 120 V. ELECTRIC DAMPER TO 120V POWER SUPPLY BY DIV. 23 SMOKE/FIRE DAMPER ACTUATOR, BY DIV. 23 DUCT CEILING DISCREPANCIES. S T S S FAA DIALER POWER REMOTE SUPPLY TELEPHONE FACP 1. THIS IS A FULLY ADDRESSIBLE VOICE EVACUATION TYPE SYSTEM WITH EACH DEVICE HAVING A DISTINCT 'ADDRESS'. 2. PROVIDE NON-POWER LIMITING, PLENUM RATED WIRING. INSTALL IN EMT WHERE WIRING IS ROUTED THROUGH HAZARDOUS LOCATIONS, EXPOSED STRUCTURAL CEILINGS, INACCESSIBLE CEILINGS, AND BETWEEN AREAS SEPARATED BY MULTI-STORY ATRIUMS. ALL RACEWAY COMPONENTS SHALL BE PAINTED RED. 3. PROVIDE DUCT DETECTION FOR ALL AIR-HANDLING EQUIP- MENT OPERATING WITH A RETURN CAPACITY EXCEEDING 2000CFM, SUPPLY CAPACITY EXCEEDING 15,000CFM WITH COMMON DUCT SERVING MULTIPLE FLOORS, AND ADDITION- ALLY AS REQUIRED BY LOCAL CODES. 4. SPRINKLER SYSTEM IS A DESIGN-BUILD CONTRACT. COORD- INATE WITH SPRINKLER CONTRACTOR FOR QUANTITIES AND LOCATIONS OF ALL FLOW AND TAMPER SWITCHES, AND FOR LOCATION OF FIRE HORN/LIGHT AT EXTERIOR OF BLDG. INSTALL WITH 20% SPARE CAPACITY ON ALL INITIATING AND INDICATING APPLIANCE CIRCUITS. 5. PROVIDE 120V CIRCUIT AND LOW-VOLTAGE FIRE ALARM CONTROL CIRCUIT TO ALL SMOKE DAMPERS. COORDINATE LOCATIONS WITH MECHANICAL CONTRACTOR PRIOR TO BID. 6. COORDINATE ALL SEQUENCING OF OPERATIONS WITH LOCAL FIRE DEPARTMENT. 7. ALL DEVICES INSTALLED IN DAMP, WET OR EXTERIOR LOCATIONS SHALL BE FURNISHED WITH WP HOUSINGS. ALL DEVICES INSTALLED IN GYMNASIUMS SHALL BE FURNISHED WITH MANUFACTURER'S STANDARD WIRE GUARD PROTECTION DEVICES. 8. SYSTEM SHALL TRANSMIT REQUIRED FIRE ALARM SIGNALS TO CENTRAL MONITORING AGENCY (SELECTED BY OWNER) VIA DIALER PROVIDED IN FIRE ALARM CONTROL PANEL. 9. PROVIDE SUFFICIENT SPARE CAPACITY FOR FUTURE TENANT FINISH AREAS. PROVIDE ALL NECESSARY EXPANSION CARDS AND REMOTE POWER SUPPLIES. 10. THE ELECTICAL CONTRACTOR SHALL INCLUDE IN HIS BID AN ADDITIONAL 10% SPARE STROBES AND HORN/STROBES, INCLUDING INSTALLATION, AS MAY BE REQUIRED BY AHJ. GO INTO ALARM, THE RESPECTIVE ELEVATOR WILL RETURN DAMPERS WILL OPERATE WHEN THE FOLLOWING CONDITIONS OCCURS. SUBSEQUENTLY, IF THE THERMAL DETECTOR IN THE ELEVATOR ROOM GOES INTO ALARM, THE POWER TO THE ELEVATOR CONTROLLER WILL BE DISCONNECTED VIA A SHUNT TRIP TO THEIR PRIMARY LEVEL OR SECONDARY LEVEL AND LOCK-OUT; THE LEVEL WILL WHEN THE SMOKE DETECTORS IN THE LOBBIES, ELEVATOR SHAFT OR EQUIPMENT ROOM DEPEND UPON IF THE ELEVATOR LOBBY DETECTOR SENSES ANY SMOKE AT THE THE SUPPLY OR RETURN DUCT DETECTOR OF THE RESPECTIVE AIR HANDLING UNIT GOES INTO ALARM. FIRE/SMOKE DAMPERS SHALL BE CLOSED BY ACTUATION OF A SMOKE DETECTOR INSTALLED IN DUCT WORK WITHIN 5' OR SPOT-TYPE DETECTOR INSTALLED WITHIN 5', REFER TO PLANS TYPE AND LOCATION. BUILDING ENTRY LOCATED AT MAIN GRAPHIC MAP NEXT TO FAA INSTALL A FRAMED, MYLAR SEQUENCE OF OPERATION FOR ELEVATOR RECALL: SEQUENCE OF OPERATION FOR SMOKE DAMPERS: CIRCUIT BREAKER. RESPECTIVE LOBBY. NOTES: 2. 1. 2. 1. LOWER LEVEL ON ALARM CONDITION TO SECURITY PANEL TYPICAL DAMPERS FOR SMOKE COORDINATE EXACT QUANTITY OF ZONES WITH FIRE SPRINKLER CONTRACTOR @ OS&Y WP AT FACP MAIN ZONE 1/2" CONDUIT TO MTTB ZONE ZONE DEDICATED 120V 20A CIRCUIT UPPER LEVEL TYPICAL TO SOUND SYSTEMS FOR MUTING (PAGING SYSTEMS OVERRIDE) 120 VOLT SHUT-DOWN FOR MECH GENERAL FIRE ALARM SYSTEM NOTE: THE FIRE ALARM DEVICES SHOWN ARE FOR GENERAL LAYOUT AND GUIDELINES ONLY. THE AWARDED FIRE ALARM CONTRACTOR IS TO PROVIDE A COMPLETE SET OF SHOP DRAWINGS FOR SUBMITTAL AND APPROVAL BY THE AUTHORITY HAVING JURISDICTION. THESE DOCUMENTS ARE TO INCLUDE THE FOLLOWING INFORMATION: 1. SHOP DRAWINGS MUST BE PREPARED AND SIGNED BY A MINIMUM OF A NICET FIRE ALARM LEVEL III CERTIFIED INDIVIDUAL. 2. COMPLETE RISER DIAGRAM SHOWING ALL DEVICES BY FLOOR/AREA AS CONNECTED TO THE CIRCUIT, DEVICE ADDRESSES, WIRE COLOR CODING SCHEDULE, WIRE COUNT, WIRE TYPE AND CONDUIT FILL WITH CALCULATIONS SHOWN. 3. PROVIDE A SEQUENCE OF OPERATION (INPUT/OUTPUT MATRIX) IN COMPLIANCE WITH THE NFPA 72 ANNEX MATERIAL. THE INFORMATION PROVIDED IN THE SEQUENCE OF OPERATION MUST BE SPECIFIC TO THE PROJECT. GENERIC SEQUENCE OF OPERATIONS WILL NOT BE ACCEPTED. 4. IDENTIFY THE TYPE OF SYSTEM, I.E. CENTRAL, REMOTE, PROPRIETARY, ETC. 5. IDENTIFY THE TYPE OF AUDIBLE NOTIFICATION: TEMPORAL, STEADY, CODED, VOICE, ETC. 6. IDENTIFY THE TYPE OF VISUAL NOTIFICATION: PUBLIC OR PRIVATE MODE. 7. PROVIDE A WIRING LEGEND SPECIFIC TO TYPES USED FOR THE PROJECT. IDENTIFY IF WIRING IS ENCLOSED IN CONDUIT, OPEN WIRING, PLENUM WIRING, POWER LIMITED OR NON-POWER LIMITED 8. PROVIDE AN EQUIPMENT LIST WITH MANUFACTURER, PART NUMBER, BACK BOX AND SYMBOL USED TO IDENTIFY THE COMPONENT. IF THERE IS INSUFFICIENT SPACE FOR WIRING LEGEND, EQUIPMENT LIST AND SYMBOL LEGEND ON THE TITLE SHEET, THAN INSERT AN ADDITIONAL SHEET. 9. COMPLETE RISER DIAGRAM SHOWING ALL DEVICES BY FLOOR/AREA AS CONNECTED TO THE CIRCUIT, DEVICE ADDRESSES, WIRE COLOR CODING SCHEDULE, WIRE COUNT, WIRE TYPE AND CONDUIT FILL WITH CALCULATIONS SHOWN. 10. DETAIL SHEET INCLUDING THE FOLLOWING; CIRCUIT WIRING DIAGRAM, DEVICE/APPLIANCE MOUNTING HEIGHT PROFILE, TYPICAL DEVICE AND ANCILLARY DEVICE WIRING, AND THE INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS. 11. PROVIDE VOLTAGE DROP CALCULATIONS FOR EACH CIRCUIT SHOWING WIRE SIZE, CIRCUIT LOAD AND VOLTAGE DROP. 12. PROVIDE AUDIO CIRCUIT POWER LOSS CALCULATIONS 13. VOLTAGE DROP CALCULATIONS MUST BE PERFORMED USING THE OUTPUT CIRCUIT VOLTAGE WHEN THE INPUT VOLTAGE TO THE CONTROL PANEL IS 85% OF ITS NAME PLATE VOLTAGE. (NFPA 72, 2002 ED., SECTION 4.4.4.1(1)) 14. PROVIDE RESISTANCE VALUES WITH SUPPORTING DATA SHEETS OR PROVIDE NEC VALUES AND REFERENCE. 15. INDICATE METHOD USED AND SHOW ALL FORMULAS/EQUATIONS. 16. PROVIDE STAND-BY BATTERY CALCULATIONS FOR EACH CONTROL PANEL, SUB PANEL, MONITORING STATION TRANSMITTER, POWER SUPPLY OR ANY COMPONENT REQUIRING SECONDARY POWER. 17. SHOW LOCATION OF ALL FIRE ALARM INITIATING DEVICES AND NOTIFICATION APPLIANCES WITH TEMPERATURE, DECIBLE AND CANDELA RATINGS, WHEN APPLICABLE. RECALL FOR ELEVATOR S S POWER REMOTE SUPPLY TYPICAL 120 VOLT SHUTDOWN FOR MECH RECALL FOR ELEVATOR S S MECH T/S ROOF LEVEL TYPICAL. REFER TO PLANS FOR EXACT QUANTITY. S T TYPICAL RECALL FOR ELEVATOR TO (E) FACP EVAC AMP VOICE S VECP VOICE EVAC CONTROL PANEL AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 NTS 10 / 3 1 / 2 0 1 6 1 1 : 3 6 : 0 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL DIAGRAMS E401 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1/8" = 1'-0"1 FIRE SMOKE DAMPER DETAIL NTS2LOW VOLTAGE RISER DIAGRAM NTS3FIRE ALARM RISER DIAGRAM1 DLM Wall Switch LMSW-Series LMRJ Series Pre-Terminated Cables or CAT5e. Free Topology & Splitter Acceptable (As Needed) Lighting Load (a) Lighting Load (b) Yel Red Re d Neutral Wht Neutral Wht Lighting Load (c) *DLM Occupancy Sensor *NOTE: Corner mount Sensor shown with pigtail & supplied coupler. Ceiling mount Sensor has two RJ45 ports. Unswitched Hot Blk 120/277 LMRJ-C8 Coupler LMRC-102 Dual Relay On/Off Room Controller LMRC-101 Single Relay On/Off Room Controller Unswitched Hot Blk 120/277 ADDITIONAL ROOM CONTROLLERS AS REQUIRED PER QUANTITY OF ZONES IN ROOM Red Yel Lighting Load (c) Blu Lighting Load (a) Lighting Load (b) Vi o Gr y Vio Gry Vio Gry Vio Gry Vi o Gr y Vi o Gr y Class 2 0-10 Volt Control Wiring 0-10VDC Dimming Ballast required. LMRJ Series Pre-Terminated Cables or CAT5e. Free Topology & Splitter Acceptable 120/230/277 Hot Blk Neutral Wht LMRC-213 Dimming Room Controller LMLS-500 Photosensor RJ45 Port (Typical) LMDM-101 Dimming Switches with LMSW-103 Scene Switch Red Red Common +24VDC Control Output Hot Neutral Blk Wht 120VAC 277VAC BZ-150 Br o w n Bl a c k Gr e y Or a n g e Re d Bl u e Cap Cap Auto ON Man ON COM SW1 LVSW-101 Low Voltage Switch Input Fixture A Sensor Ceiling/Wall 24VDC Any *To Additional Sensor(s) Any Line Voltage Occupancy Sensor Using Terminals Any Line Voltage Occupancy Sensor Using Terminals Load Load Line Neutral Ground Load Line Neutral GroundNeutral Hot Neutral LOCAL OFF SWITCH QUANTITY AS NECESSARY T 'RP2A'120V WATTSTOPPER MAIN LEVEL ELECTRICAL ROOM EC PROVIDED CAT6 CABLING NOTE: THIS SCHEMATIC SHOWS AN INTENT OF THE EQUIPMENT CONNECTIONS FOR THE OVERALL CONTROL OF THE BUILDING PUBLIC AREA LIGHTING SYSTEMS. IT DOES NOT REPRESENT ACTUAL WIRING DIAGRAMS. THE ELECTRICAL CONTRACTOR MUST COORDINATE WITH THE LIGHTING CONTROL MANUFACTURER AND SUBMIT THE ACTUAL WIRE DIAGRAMS FOR EQUIPMENT INTERCONNECTION AS PART OF THE SUBMITTAL PROCESS. 120V BACNETIP INTEGRATION ADJACENT TO 'RP1' EC PROVIDED CAT6 CABLING 32 RELAY PANEL 'WS6' CARDIO 'WS7' POOL LIFEGUARD 'WS8' XXX 'RP2B' WATTSTOPPER MAIN LEVEL SATELITTE ELEC 32 RELAY PANEL 'RP1B' WATTSTOPPER LOWER LEVEL ELEC ROOM 109 32 RELAY PANEL PC NATATORIUM PHOTOCELL (OPEN LOOP) FOR PRICING ASSUME QUANTITY OF (4) 'WS1' LOBBY RECEPTION DESK 'WS2' LOUNGE RECEPTION DESK 'WS3' FITNESS 'WS4' GYM 'WS5' MAINTENANCE ENTRY AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 9 : 2 0 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 LIGHTING CONTROL SCHEDULES AND DIAGRAMS E402 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 1/8" = 1'-0"1 LIGHTING CONTROL DIAGRAM - CEILING VACANCY SENSOR AND DIMMING 1/8" = 1'-0"2 LIGHTING CONTROL DIAGRAM - DAYLIGHT HARVEST 1/8" = 1'-0"3 LIGHTING CONTROL DIAGRAM - CEILING SENSORS, VACANCY MODE 1/8" = 1'-0"4 LIGHTING CONTROL DIAGRAM - CEILING OCCUPANCY SENSORS 1/8" = 1'-0"5 LIGHTING CONTROL ONE-LINE DIAGRAM & DETAILS LIGHTING CONTROL DEVICES TYPE DESCRIPTION MANUFACTURER CATALOGUE PROGRAMMING REQUIREMENTS NOTES LVD1 LOW-VOLTAGE DIMMING WALL SWITCH (ROOM CONTROLLER CONFIGURATION) WATTSTOPPER LMDM-100 SERIES LVKS LOW-VOLTAGE KEYED SWITCH TBD TBD OSC2 CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WATTSTOPPER DT-300 SERIES AUTO-ON, AUTO-OFF AFTER 30 MINUTES OSC3 CORNER-MOUNT DUAL TECHNOLOGY OCCUPANCY SENSOR WATTSTOPPER DT-200 SERIES AUTO-ON, AUTO-OFF AFTER 30 MINUTES PC1 LOW-VOLTAGE, OPEN-LOOP PHOTOSENSOR WATTSTOPPER LMLS-500 MAINTAIN MINIMUM SETPOINT OF 35 FC AT FINISHED FLOOR. RCD1 SINGLE RELAY ROOM CONTROLLER, 0-10V DIMMING WATTSTOPPER LMRC-211 RE: E402 RCD2 DUAL RELAY ROOM CONTROLLER, 0-10V DIMMING WATTSTOPPER LMRC-212 RE: E402 RCD3 3-RELAY ROOM CONTROLLER, 0-10V DIMMING WATTSTOPPER LMRC-213 RE: E402 RCD4 MULTI-ZONE ROOM CONTROLLER, 0-10V DIMMING (COMMUNITY ROOM) CRESTRON GLPAC8-3OS-TS-X( *)-XX-EXP ZONE RE: E403, PROVIDE EPANSION FOR (1) ADDITIONAL SWITCHED ZONE. (*)EC SHALL COORDINATE SHADE MOTOR TYPE WITH APPROVED MOTORIZED SHADE EQUIPMENT SHOP DRAWINGS PRIOR TO PURCHASE. TS WALL TIMER SWITCH WATTSTOPPER TBD MANUAL ON, AUTO-OFF PER TIMER SELECTION VS1 SINGLE RELAY WALL MOUNTED DUAL TECHNOLOGY VACANCY SENSOR WATTSTOPPER DSW-301 SERIES MANUAL ON, AUTO-OFF AFTER 30 MINUTES VSC1 CEILING MOUNTED DUAL TECHNOLOGY DLM VACANCY SENSOR (ROOM CONTROLLER CONFIGURATION) WATTSTOPPER LMDC-100 SERIES MANUAL ON, AUTO-OFF AFTER 30 MINUTES VSC2 CELING MOUNTED DUAL TECHNOLOGY VACANCY SENSOR WATTSTOPPER DT-300 SERIES MANUAL ON, AUTO-OFF AFTER 30 MINUTES VSC3 CORNER-MOUNT DUAL TECHNOLOGY DLM VACANCY SENSOR WATTSTOPPER LMDX-100 MANUAL ON, AUTO-OFF AFTER 30 MINUTES VSC4 CEILING MOUNTED DUAL TECHNOLOGY VACANCY SENSOR (COMMUNITY ROOM) CRESTRON GLS-ODT-C-2000 MANUAL ON, AUTO-OFF AFTER 30 MINUTES RE: E403 DIN-PWS50 DIN-AP2 Serial RS-232 To Shade Control (if Required) CEN-SW-POE-5 TSW-750TSW-750TSW-750 GLPAC-DIM8 120VAC SUPPLY 120VAC SHADES SWITCHED (UP/DOWN) GLS-PART GLS-PART GLS-SIM GLS-SIM CRESNET CABLE: (1) PAIR # 18AWG, (1) TWISTED PAIR 22AWG (1) SHIELD (TS1) (TS1) (TS1) CRESNET CABLE: (1) PAIR # 18AWG, (1) TWISTED PAIR 22AWG (1) SHIELD DIN-IN-2X18 COMMUNITY ROOMS CAT5 CAT5 COMMUNITY ROOMS: THE INTENT FOR THIS SPACE IS HAVE A FULLY AUTOMATED CONTROL FOR THE FOLLOWING COMPONENTS: PARTITIONS, SHADES AND LIGHTS. A/ V SY S T E M TBD LI G H T I N G SY S T E M S AMBIENT LIGHTING: (3) ZONES OF 0-10V FULLY DIMMABLE FIXTURES. FIXTURES SHALL ACT AS (3) ZONES WHEN PARTITIONS ARE CLOSED, (2) ZONES WHEN A SINGLE PARTITION IS CLOSED, AND (1) ZONE WHEN PARTITIONS ARE OPEN. ACCENT/COVE LIGHTING: (3) ZONES OF 0-10V FULLY DIMMABLE FIXTURES. FIXTURES SHALL ACT AS (3) ZONES WHEN PARTITIONS ARE CLOSED, (2) ZONES WHEN A SINGLE PARTITION IS CLOSED, AND (1) ZONE WHEN PARTITIONS ARE OPEN. WHEN A PARTITION IS OPEN THE SYSTEM SHALL TREAT THE SPACES ADJACENT TO OPEN PARTION AS A SINGLE ROOM (IE WHEN PARTITION IS OPEN ADJACENT ROOM AMBIENT LIGHTING CONTROL SHALL ACT AS A SINGLE ZONE).PA R T I T I O N S DECORATIVE PENDANT LIGHTING: (3) ZONES OF SWITCHED LIGHTING. FIXTURES SHALL ACT AS (3) ZONES WHEN PARTITIONS ARE CLOSED, (2) ZONES WHEN A SINGLE PARTITION IS CLOSED, AND (1) ZONE WHEN PARTITIONS ARE OPEN. CONTROL SYSTEM GENERAL NOTES: 1 ALL EQUIPMENT SHOWN ON THESE DETAILS IS MANUFACTURERED BY CRESTRON. THESE ONE-LINE DIAGRAMS ARE FOR CONCEPT ONLY. THESE ARE NOT INTENDED TO BE USED AS WIRING DIAGRAMS. EC SHALL CONFIRM ALL PARTS & PIECES WITH MANUFACTURER PRIOR TO ORDER TO ENSURE THE FUNCTIONALITY OF THE SYSTEM MATCHES THE ITEMS OUTLINED IN THE "INTENT" PORTION OF THESE NOTES. INTERNAL TIMECLOCK SHALL BE SET TO BE TURNED ON 30 MIN PRIOR TO OPENING UNTIL 1 HOUR AFTER CLOSE, WITH 2 HOUR OVERRIDE OPTIONS FROM THE TOUCHSCREEN PANELS. 2 3 4 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 NTS 10 / 3 1 / 2 0 1 6 1 1 : 3 9 : 3 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 LIGHTING CONTROL DIAGRAMS E403 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NTS1COMMUNITY ROOMS CONTROL SYSTEM DIAGRAM RELAY PANEL - RP1B RELAY SWITCH ID RELAY DESCRIPTION CONT. SEQUENCE RELAY VOLTAGE PANEL CKT # RP1B-1 LOUNGE LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 7 RP1B-2 RECEPTION DESK RECESSED LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 7 RP1B-3 RECEPTION DESK PENDANT LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 7 RP1B-4 RECEPTION DESK COVE LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 9 RP1B-5 STRENGTH/HALL LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 13 RP1B-6 UNDER TRACK LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 15 RP1B-7 EXTERIOR BUILDING LIGHTING - NORTH AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL1B 16 RP1B-8 MONUMENT SIGN AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 120 V LP1B 83 RELAY PANEL - RP2A RELAY SWITCH ID RELAY DESCRIPTION CONT. SEQUENCE RELAY VOLTAGE PANEL CKT # RP2A-1 NATATORIUM LIGHTING - SOUTH AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 16 RP2A-2 NATATORIUM LIGHTING - NORTHEAST AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 15 RP2A-3 NATATORIUM LIGHTING - WEST AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 17 RP2A-4 EXTERIOR SITE POLE LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS 277 V HL2B 22 RP2A-5 EXTERIOR SITE PEDESTRIAN LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS 277 V HL2B 20 RP2A-6 EXTERIOR SITE POLE LIGHTING - SECURITY AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 30 MINUTES AFTER SUNRISE 277 V HL2B 22 RP2A-7 EXTERIOR SITE PEDESTRIAN LIGHTING - SECURITY AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 30 MINUTES AFTER SUNRISE 277 V HL2B 20 RP2A-8 EXTERIOR BOLLARD LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS 277 V HL2B 20 RP2A-9 EXTERIOR BOLLARD LIGHTING - SECURITY AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO SUNSET, AUTO-OFF VIA TIMECLOCK 30 MINUTES AFTER SUNRISE 277 V HL2B 20 RP2A-10 NATATORIUM FOYER & ENTRY CORRIDOR AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HA2A 19 RP2A-11 EXTERIOR BUILDING LIGHTING - EAST AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HA2A 21 RP2A-12 EXTERIOR BUILDING LIGHTING - WEST AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HA2A 21 RP2A-13 POOL LIGHTS AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 120 V LP2A 34 RELAY PANEL - RP2B RELAY SWITCH ID RELAY DESCRIPTION CONT. SEQUENCE RELAY VOLTAGE PANEL CKT # RP2B-1 OFFICE CORRIDOR LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 2 RP2B-2 LOBBY LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 4 RP2B-3 LOBBY RECEPTION DESK LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 4 RP2B-5 ABOVE TRACK LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 7 RP2B-6 NORTH GYM LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 8 RP2B-7 NORTH GYM LIGHTING - EMERGENCY AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 9 RP2B-8 SOUTH GYM LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 10 RP2B-9 SOUTH GYM LIGHTING - EMERGENCY AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 11 RP2B-10 CARDIO LINEAR LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 7 RP2B-11 LOBBY LARGE PENDANT LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 4 RP2B-12 STAIR LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 277 V HL2B 6 RP2B-13 LOBBY RECEPTION DESK LIGHTING AUTO-ON VIA TIMECLOCK 30 MINUTES PRIOR TO START OF BUSINESS, AUTO-OFF VIA TIMECLOCK 1 HOUR AFTER CLOSE OF BUSINESS. 120 V LP2B 84 WS1 BUTTON CONFIGURATION BUTTON RELAYS CONTROLLED 'LOUNGE' RP1B-1 'RECPT. DESK' RP1B-2,3,4 'STRENGTH' RP1B-6 RP1B-5 'LOWER TRACK' RP2B-6,7,8,9'GYM' TBDSPARE A. B. C. D. E. F. G. H. I. MECHANICAL EQUIPMENT GENERAL NOTES REFER TO MECHANICAL PLANS FOR SPECIFIC EQUIPMENT LOCATIONS AND REQUIREMENTS. PRIOR TO ROUGH-IN, COORDINATE ALL MECHANICAL EQUIPMENT POWER AND CONNECTION REQUIREMENTS WITH MECHANICAL CONTRACTOR'S FINAL SHOP DRAWINGS. PROVIDE ALL 120V CONTROL WIRING, REFER TO SPECIFICATIONS FOR FURTHER CONTROL WIRING CLARIFICATION. FOR ANY VAV SYSTEM COORDINATE POWER REQUIREMENTS WITH MECHANICAL CONTRACTOR AND PROVIDE 120V CONNECTIONS AT EACH VAV BOX, OR AT CENTRAL CONTROL PANEL LOCATION(S) AS REQUIRED. IF EXACT QUANTITIES AND LOCATIONS FOR CONTROL PANELS ARE NOT KNOWN AT BID TIME, E.C. IS TO INCLUDE ONE 120V CONNECTION AT EACH VAV DEVICE IN THE BASE BID PRICE AND PROVIDE A CREDIT DURING CONSTRUCTION IF LESS CONNECTIONS ARE REQUIRED. EXTERIOR DISCONNECT SWITCHES ARE TO BE PROVIDED AS NEMA 3R EQUIPMENT UNLESS OTHERWISE NOTED. PROVIDE WEATHERPROOF 120 VOLT GFCI RECEPTACLES WITHIN 25' OF ALL ROOFTOP HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. CIRCUIT TO SPARE CIRCUIT ON NEAREST 120V PANELBOARD OR AS INDICATED ON PLANS. PROVIDE DUCT DETECTION ON ALL RETURN AIR SYSTEMS OF 2,000 CFM OR GREATER, AND FOR ALL SUPPLY AIR SYSTEMS 15,000 CFM OR GREATER, INCLUDING THOSE SYSTEMS SERVING MULTIPLE FLOORS. PROVIDE ADDITIONAL DUCT DETECTORS AND INSTALL REMOTE INDICATOR LIGHTS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. FOR ANY BOILER MECHANICAL SYSTEM, E.C. IS TO PROVIDE AN EMERGENCY PUSHBUTTON OFF AND ANY CONTROL WIRING REQUIRED. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR AND EQUIPMENT PRIOR TO INSTALLATION. EC TO PROVIDE HAND/OFF/AUTO STARTERS FOR ALL MOTORS WHEN NOT INDICATED AS TO BE PROVIDED BY THE MECHANICAL CONTRACTOR ON THE MECHANICAL PLANS. SIZE OF STARTER TO BE BASED UPON SIZE OF MOTOR HORSEPOWER INDICATED. GENERAL NOTES SPECIFIC NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. UNIT POWERED FROM DSCU-1. TIE INTO LOCAL LIGHTING OCCUPANCY SENSOR SWITCH. PROVIDE SEPERATE PRICING FOR ELECTRICAL CONNECTIONS FOR MECHANICAL ALTERNATE UNIT AS NOTED ON MECHANICAL DRAWINGS, PER ALTERNATE #2. PROVIDE (1) 120V, 20AMP CIRCUIT FOR CONTROL PANEL. EC SHALL PROVIDE ELECTRICAL CONNECTIONS FOR CONTROL PANELS, POOL CONTRACTOR TO PROVIDE WIRING TO PUMPS AS INDICATED ON MECHANICAL DRAWINGS. COORDINATE FAN SPEED SWITCH CONNECTION REQUIREMENTS PRIOR TO ROUGH-IN. EC SHALL PROVIDE FIRE ALARM TIE-IN TO CEILING FAN CONTROLS CONTRACTOR FOR FIRE ALARM SYSTEM SHUT DOWN OF CEILING FAN UPON ACTIVATION OF FIRE ALARM CONDITION. CEILING FAN CONTROLS CONTACTOR SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY EC. COORDINATE EXACT CONNECTION REQUIREMENTS WITH MECHANICAL DRAWINGS PRIOR TO ROUGH-IN. EC SHALL CONFIRM OVERCURRENT PROTECTION FOR ELEVATOR IS COORDINATED WITH MANUFACTURER'S SHOP DRAWING SUBMITTALS, FOR THE ACTUAL EQUIPMENT TO BE INSTALLED. ELEVATOR CONTROLLER LOCATED IN MANUFACTUER POWER CONTROL PANEL WITH 80A/3P SHUNT TRIP CIRCUIT BREAKER. COODRINATE AUXILLARY CONTACTS WITH MANUFACTURER'S APPROVED ELEVATOR SHOP DRAWINGS FOR FIRE ALARM RECALL CAPABILITY. BOILER SHALL BE PROVIDED WITH 'EPO' TYPE SWITCH FOR EMERGENCY SHUT DOWN OF BOILER POWER. EPO SWITCH FURNISHED AND INSTALLED BY TEMPERATURE CONTROLS CONTRACTOR AND WIRED BY EC. COORDINATE EXACT CONNECTION REQUIREMENTS AND MOUNTING LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH-IN. EC SHALL INTERCONNECT SHUNT TRIP BREAKER WITH MECHANICAL EXHAUST HOOD, PROVIDE CONTROLS AS NOTED IN MECHANICAL DRAWINGS. POOL EQUIPMENT NOTES A PROVIDE 120V CONTROL WIRING AS REQUIRED PER POOL EQUIPMENT SCHEDULE ON POOL DRAWINGS. B REFER TO POOL DRAWINGS FOR EQUIPMENT LOCATIONS. C FIELD VERIFY ALL EQUIPMENT LOADS, VOLTAGES, AND RECOMMENDED FUSE SIZING PRIOR TO ENERGIZING CIRCUIT. D THE ELECTRICAL CONTRACTOR SHALL REVIEW ALL AQUATICS PLANS AND PROVIDE ALL WORK AS CALLED OUT TO BE COMPLETED BY THE ELECTRICAL CONTRACTOR. COORDINATE WITH POOL CONTRACTOR. E ALL DISCONNECTS SHALL BE NEMA 3R RATED WITH NON-METALLIC ENCLOSURE AND STAINLESS STEEL HARDWARE FOR CORROSION RESISTANCE. F MOTORS REQUIRING STARTERS SHALL UTILIZE COMBINATION START/DISCONNECT. STARTERS SHALL BE NON-REVERSING WITH NEMA SIZE AS LISTED. ALL STARTERS SHALL UTILIZE CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION. UNITS NOTED TO BE CONTROLLED WITH VFD SHALL BE PROVIDED AS A COMBINATION VFD/DISCONNECT, SPECIFIED IN AQUATICS DRAWINGS. G PROVIDE FLEXIBLE CONDUIT CONNECTION AT ALL PUMP MOTORS, MINIMUM 18" IN LENGTH. H WHERE MOTOR IS WITHIN SIGHT (PER THE DEFINITION OF THE NEC) OF THE MCC, THE INDICATED DISCONNECT SWITCH IS NOT REQUIRED. I ALL MOTORS GREATER THAN 7.5 HORSEPOWER ARE TO BE PROVIDED WITH THREE PHASE PROTECTION. J ELECTRICAL CONTRACTOR SHALL REFERENCE POOL WIRING DIAGRAMS AND SEQUENCE OF OPERATIONS FOR INTERLOCKS PROVIDED ON THE AQUATIC DESIGNERS DRAWINGS. L PROVIDE CLEARLY LABELED EMERGENCY SHUTOFF BUTTONS FOR THE PURPOSE OF STOPPING THE MOTORS THAT PROVIDE POWER TO ALL NON-FILTRATION PUMPS PER POOL ENGINEER. EMERGENCY SHUTOFF BUTTON LOCATIONS SHALL BE COORDINATED WITH THE OWNER OR THE OWNER'S RISK MANAGEMENT CONSULTANT. M EC SHALL REFER TO THE POOL CONSTRUCTION DRAWINGS FOR DELINEATION OF RESPONSIBILITIES BETWEEN POOL AND ELECTRICAL CONTRACTORS FOR WHO FURNISHES AND INSTALLS POOL EQUIPMENT, AS WELL AS WHO PROVIDES LINE, LOW VOLTAGE, AND CONTROL WIRING CONNECTIONS. 1 ANTICIPATED FUTURE INSTALLATION OF EQUIPMENT, PROVIDED FOR APPROXIMATE ELECTRICAL LOAD USAGE TO ACCOMODATE FUTURE LOADS ON NEW SERVICE/PANELS. GENERAL NOTES SPECIFIC NOTES 2 REFER TO PLANS FOR EPO/TIMER JUNCTION BOX LOCATIONS AND CONDUIT REQUIREMENTS FOR FUTURE INSTALLATION PER AQUATICS DRAWINGS. 3 EC SHALL PROVIDE A COMBINATION MOTOR STATER WITH "START-STOP" BUTTONS AND VARIABLE FREQUENCY DRIVE WITH MANUAL BYPASS. 4 WET NICHE POOL LIGHT LOCATION. LIGHT NICHE PROVIDED AND INSTALLED BY POOL CONTRACTOR. NICHE SHALL BE GROUNDED/BONDED BY THE ELECTRICAL CONTRACTOR. WET NICHE LUMINAIRES SHALL BE FURNISHED BY THE POOL CONTRACTOR AND INSTALLED BY THE ELECTRICAL CONTRACTOR. WATERTIGHT CONDUIT, POOL RATED JUNCTION BOXES, CONTROLS, AND GFI PROTECTION SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR IN ACCORDANCE WITH NEC ARTICLE #680. 5 ACID PUMP 1 SHALL BE FED FROM CHEMICAL CONTROLLER 1. CORD PLUGS INTO CHEMICAL CONTROLLER RECEPTACLE. RE: AQUATICS. 6 RE: RELAY PANEL RP2A FOR CIRCUITING INFORMATION AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 As indicated 10 / 3 1 / 2 0 1 6 1 1 : 1 9 : 5 0 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL SCHEDULES E500 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O MECHANICAL SCHEDULE KEY EQUIPMENT DESCRIPTION LOAD ELECTRICAL MOCP FEEDER DISCONNECT PANEL CIRCUIT NOTES B 1 BOILER 12 FLA 120 V/1-1440 VA 15 2#12, #12G, 3/4"C $TO LP2A 4 8 B 2 BOILER 12 FLA 120 V/1-1440 VA 15 2#12, #12G, 3/4"C $TO LP2A 5 8 B 3 BOILER 12 FLA 120 V/1-1440 VA 15 2#12, #12G, 3/4"C $TO LP2A 6 8 CF 1 CEILING FAN 1070 VA 480 V/3-1070 VA 15 3#12, #12G, 3/4"C INTEGRAL HM2B 1,3,5 6 CF 2 CEILING FAN 1070 VA 480 V/3-1070 VA 15 3#12, #12G, 3/4"C INTEGRAL HM2B 1,3,5 6 CF 3 CEILING FAN 900 VA 480 V/3-900 VA 15 3#12, #12G, 3/4"C INTEGRAL HM2A 14,16,18 6 CF 4A CEILING FAN (ALTERNATE) 850 VA 480 V/3-850 VA 15 3#12, #12G, 3/4"C INTEGRAL HM2A 21,23,25 3,6 CF 5A CEILING FAN (ALTERNATE) 850 VA 480 V/3-850 VA 15 3#12, #12G, 3/4"C INTEGRAL HM2A 22,24,26 3,6 CP 1 CIRCULATION PUMP 1/6 HP 120 V/1-528 VA 15 2#12, #12G, 3/4"C 30A/1P LP2A 7 CP 2 CIRCULATION PUMP 1/6 HP 120 V/1-528 VA 15 2#12, #12G, 3/4"C 30A/1P LP2A 8 CP 3 CIRCULATION PUMP 1/6 HP 120 V/1-528 VA 15 2#12, #12G, 3/4"C 30A/1P LP2A 9 CUH 1 CABINET UNIT HEATER 2.24 FLA 120 V/1-269 VA 15 2#12, #12G, 3/4"C $TO LP2A 13 CUH 2 CABINET UNIT HEATER 2.24 FLA 120 V/1-269 VA 15 2#12, #12G, 3/4"C $TO LP2A 13 CUH 3 CABINET UNIT HEATER 2.24 FLA 120 V/1-269 VA 15 2#12, #12G, 3/4"C $TO LP1B 3 CUH 4 CABINET UNIT HEATER 2.24 FLA 120 V/1-269 VA 15 2#12, #12G, 3/4"C $TO LP1B 1 CUH 5 CABINET UNIT HEATER 4.88 FLA 120 V/1-586 VA 15 2#12, #12G, 3/4"C $TO LP1B 1 DSCU 1 DUCTLESS SPLIT SYSTEM CONDENSING UNIT 15.6 FLA 208 V/2-3245 VA 20 2#12, #12G, 3/4"C 30A/2P LP2B 2,4 DSIU 1 DUCTLESS SPLIT SYSTEM INDOOR UNIT -- 208 V/1-0 VA -- -- --1 EF 1 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 15 EF 2 EXHAUST FAN 1 HP 208 V/2-1840 VA 20 2#12, #12G, 3/4"C INTEGRAL LP2A 69,71 EF 3 EXHAUST FAN 81 W 120 V/1-81 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 3 2 EF 4 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 18 EF 5 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 19 EF 6 EXHAUST FAN 1 HP 208 V/2-1664 VA 15 2#10, #10G, 3/4"C INTEGRAL LP2A 14,16 EF 7 EXHAUST FAN 135 W 120 V/1-135 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 1 2 EF 8 EXHAUST FAN 135 W 120 V/1-135 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 1 2 EF 9 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 6 EF 10 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 7 EF 11 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 8 EF 12 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 9 EF 13 EXHAUST FAN 3.3 FLA 120 V/1-348 VA 15 2#12, #12G, 3/4"C INTEGRAL LP1B 76 EF 14 EXHAUST FAN 3/4 HP 120 V/1-1656 VA 25 2#10, #10G, 3/4"C INTEGRAL LP2A 20 EF 15 EXHAUST FAN 1/4 HP 120 V/1-696 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 10 EF 16 EXHAUST FAN 1.1 FLA 120 V/1-128 VA 15 2#12, #12G, 3/4"C INTEGRAL LK1B 19 EF 17 EXHAUST FAN 1 HP 208 V/2-1664 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 73,75 ELEV 1 ELEVATOR 20 HP 480 V/3-31868 VA 100 3#1, 1#6G, 1-1/2"C 100A/3P MDC 15 7 GWH 1 GAS WATER HEATERS 2 A 120 V/1-240 VA 15 2#12, #12G, 3/4"C $TO LP2A 11 GWH 2 GAS WATER HEATERS 2 A 120 V/1-240 VA 15 2#12, #12G, 3/4"C $TO LP2A 11 GWH 3 GAS WATER HEATERS 2 A 120 V/1-240 VA 15 2#12, #12G, 3/4"C $TO LP2A 11 KH 1 KITCHEN HOOD 15 FLA 120 V/1-1800 VA 20 2#12, #12G, 3/4"C INTEGRAL LK1B 21 9 MAU 1 GAS FIRED MAKE-UP-AIR UNIT 4.24 FLA 480 V/3-3525 VA 15 3#12, #12G, 3/4"C 30A/3P HM2A 13,15,17 P 1 PUMP 1.5 HP 480 V/3-2494 VA 15 3#12, #12G, 3/4"C 30A/3P HM2A 1,3,5 P 2 PUMP 1.5 HP 480 V/3-2494 VA 15 3#12, #12G, 3/4"C 30A/3P HM2A 7,9,11 PDU 1A NATATORIUM DEHUMIDIFICATION/HEAT RECOVERY UNIT - ALTERNATE 31.2 FLA 480 V/3-25908 VA 50 3#6, 1#10G, 1"C 60A/3P HM2A 8,10,12 3 PDU 2 NATATORIUM DEHUMIDIFICATION/HEAT RECOVERY UNIT 29.1 FLA 480 V/3-25908 VA 40 3#8, 1#10G, 1"C 60A/3P HM2A 2,4,6 PP 1 IN-LINE PUMP 2/5 HP 120 V/1-1176 VA 20 2#12, #12G, 3/4"C $TO LP2A 10 RTU 1 ROOF TOP UNIT 91.7 FLA 480 V/3-76235 VA 125 4#1/0,1#6G, 1-1/2"C INTEGRAL MDC 12 RTU 2 ROOF TOP UNIT 69.2 FLA 480 V/3-57530 VA 90 4#2, 1#8G, 1-1/2"C INTEGRAL MDC 13 RTU 3 ROOF TOP UNIT 183.3 FLA 480 V/3-152388 VA 225 4#4/0, 1#4G, 2-1/2"C INTEGRAL MDC 14 SE 1,2 SEWAGE EJECTOR PUMP 1/2 HP 120 V/1-1176 VA 20 2#12, #12G, 3/4"C 30A/1P LA2A 2 4 SP 1 SUMP PUMP 1/2 HP 120 V/1-1176 VA 20 2#12, #12G, 3/4"C 30A/1P LP1B 74 4 TF 1 TRANSFER FAN 81 W 120 V/1-350 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2B 1 5 TF 2 TRANSFER FAN 285 W 120 V/1-350 VA 15 2#12, #12G, 3/4"C INTEGRAL LP1B 17 5 TF 3 TRANSFER FAN 350 W 120 V/1-350 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 3 5 UH 1 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 13 5 UH 2 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 13 5 UH 3 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 13 5 UH 4 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP1B 3 5 UH 5 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP1B 1 5 UH 6 UNIT HEATER 0.8 FLA 120 V/1-96 VA 15 2#12, #12G, 3/4"C INTEGRAL LP2A 17 5 POOL EQUIPMENT SCHEDULE KEY # LOAD EQUIPMENT DESCRIPTION ELECTRICAL DATA MOCP FEEDER DISCONNECT STARTER AUX CONTACTS PANEL CIRCUIT NOTES AC 1 15 A DEFENDER FILTER AIR COMPRESSOR 120 V/1-1800 VA 20 2#12, #12G, 3/4"C NEMA 5-20R LA2A 4 AP 1 1/30 HP ACID PUMPS 120 V/1-120 VA 20 PROVIDED CORD/PLUG LA2A 6 5 CC 1 10 A CHEMICAL CONTROLLER 120 V/1-1200 VA 20 2#12, #12G, 3/4"C NEMA 5-20R LA2A 7 CCBP 1 1/2 HP CLEAR COMFORT BOOSTER PUMP 1 120 V/1-1176 VA 20 2#12, #12G, 3/4"C $TO LA2A 1 CCEB 1 1/2 HP CHEMICAL CABINET EXHAUST BLOWER 1 120 V/1-1176 VA 20 2#12, #12G, 3/4"C $TO LA2A 8 CCEB 2 1/2 HP CHEMICAL CABINET EXHAUST BLOWER 2 120 V/1-1176 VA 20 2#12, #12G, 3/4"C $TO LA2A 9 CCS 1 10 A CLEAR COMFORT SUPPLIMENTAL TREATMENT 120 V/1-1200 VA 20 2#12, #12G, 3/4"C $TO LA2A 12 CH 1 15 A PPG CHLORINATOR 120 V/1-1800 VA 20 2#12, #12G, 3/4"C $TO LA2A 11 CP 1 40 HP LEISURE POOL CURRENT PUMP 1 480 V/3-41430 VA 90 3#2, 1#8G, 1-1/4"C 100A/3P NEMA TYPE 3 (1) NC, (1) NO HA2A 8,10,12 3 CP 2 40 HP LEISURE POOL CURRENT PUMP 2 480 V/3-41430 VA 90 3#2, 1#8G, 1-1/4"C 100A/3P NEMA TYPE 3 (1) NC, (1) NO HA2A 13,15,17 3 ECH 3 100 W EXISTING POOL CHLORINATOR 120 V/1-100 VA 20 2#12, #12G, 3/4"C $TO LA2A 15 FC 1 20 A DEFENDER FILTER CONTROLLER 1 120 V/1-1800 VA 20 2#12, #12G, 3/4"C NEMA 5-20R LA2A 3 LAP 1 5 HP LEISURE AMENITY PUMP 1 480 V/3-6057 VA 15 3#12, #12G, 3/4"C 30A/3P NEMA TYPE 0 (1) NC, (1) NO HA2A 1,3,5 3 LAP 2 5 HP LEISURE AMENITY PUMP 2 480 V/3-6057 VA 15 3#12, #12G, 3/4"C 30A/3P NEMA TYPE 0 (1) NC, (1) NO HA2A 2,4,6 3 LCP 1 7.5 HP LEISURE CIRCULATION PUMP 480 V/3-8769 VA 20 3#12, #12G, 3/4"C 30A/3P NEMA TYPE 1 (1) NC, (1) NO HA2A 7,9,11 3 LH 1 15 A LEISURE HEATER 120 V/1-1800 VA 20 2#12, #12G, 3/4"C $TO LA2A 5 WN A 100 W LEISURE POOL WET NICHE LIGHTING 120 V/1-100 VA 20 2#12, #12G, 3/4"C RELAY 4,5 FUTURE POOL EQUIPMENT SCHEDULE KEY # LOAD EQUIPMENT DESCRIPTION ELECTRICAL DATA MOCP FEEDER DISCONNECT NOTES AP 2 1/30 HP ACID PUMPS (FUTURE) 120 V/1-120 VA 20 -- -- 1 CC 2 10 A CHEMICAL CONTROLLER (FUTURE) 120 V/1-1200 VA 20 -- -- 1 CCBP 2 1/2 HP CLEAR COMFORT BOOSTER PUMP 2 (FUTURE) 120 V/1-1176 VA 20 -- -- 1 CCS 2 10 A CLEAR COMFORT SUPPLIMENTAL TREATMENT (FUTURE) 120 V/1-1200 VA 20 -- -- 1 CH 2 15 A PPG CHLORINATOR (FUTURE) 120 V/1-1800 VA 20 ---- 1 FC 2 20 A DEFENDER FILTER CONTROLLER 2 (FUTURE) 120 V/1-1800 VA 20 -- -- 1 SCP 1 3 HP SPA CIRCULATION PUMP (FUTURE) 480 V/3-3828 VA 15 -- -- 1,2 SH 1 15 A SPA HEATER (FUTURE) 120 V/1-1800 VA 20 -- -- 1 SJB 1 3 HP SPA JET AIR BLOWER (FUTURE) 480 V/3-3828 VA 15 -- -- 1 SJP 1 5 HP SPA JET PUMP (FUTURE) 480 V/3-6057 VA 15 -- -- 1,2 SLCP 1 15 HP SLIDE CIRCULATION PUMP (FUTURE) 480 V/3-16737 VA 15 -- -- 1,2 A. B. C. LIGHTING FIXTURE NOTES ALL FLUORESCENT LAMPS TO BE 3500K COLOR TEMPERATURE AND A MINIMUM OF 82CRI, UNLESS NOTED OTHERWISE. ALL REFLECTOR LAMPS TO BE PROVIDED AS WIDE FLOOD DISTRIBUTION, UNLESS NOTED OTHERWISE. ALL FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE-ENDED LAMPS AND CONTAIN BALLASTS THAT CAN BE SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS AS DESCRIBED IN NEC 410.130(G). GENERAL NOTES SPECIFIC NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. COORDINATE EXACT MOUNTING WITH CEILING TYPE AT ALL LOCATIONS. COORDINATE RECESSED FIXTURE DEPTH AND CLEARANCE IN FIELD PRIOR TO PURCHASE. MANUFACTURER SHALL PROVIDE (1) LED BAR ROTATED AND AIMED UPWARD SO THAT CENTER BAR POSITION IS AIMED INDIRECTLY AT CEILING. COORDINATE CUSTOM SPECIFICATION WITH MANUFACTURER PRIOR TO PURCHASE. PROVIDE SORRA 5.6 WATT MR16 GU10 REPLACEMENT LAMP(S) (3000K, 85CRI, 36 DEGREE FLOOD) OR APPROVED EQUAL, AS REQUIRED. PROVIDE 3-BAR FIXTURE WITH (2) HIGH OUTPUT BARS AIMED DIRECTLY DOWN AND TOWARD CENTER OF POOL AND (1) STANDARD OUTPUT BAR AIMED INDIRECTLY. COORDINATE EXACT BAR SPECIFICATION, LOCATIONS AND AIMING WITH MANUFACUTURER AND APPROVED SHOP DRAWINGS PRIOR TO PURCHASE. NOT USED. NOT USED. PROVIDE LIGHTING/MOUNTING DIRECTION #2. DIRECT AWAY FROM WALL AS REQUIRED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. COORDINATE CUSTOM SUSPENDED CABLE/STEM LENGTH AT EACH LOCATION PRIOR TO PURCHASE. COORDINATE EXACT FIXTURE MOUNTING HEIGHT WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT FIXTURE LENGTH WITH PLANS AND VERIFY WITH ARCHITECT PRIOR TO PURCHASE. COORDINATE EXACT DRIVER SPECIFCIATION, QUANTITY AND MAX RUN LENGTH WITH FINAL CONNECTED FIXTURE LENGTH AND POWER REQUIREMENTS. PROVIDE ALL REQUIRED PARTS AND COMPONENTS INCLUDING CONNECTORS AND MOUNTING HARDWARE FOR A FULLY FUNCTIONAL INSTALLED SYSTEM AS INDICATED. PROVIDE BODINE ELIS-100 DIMMING EMERGENCY INVERTER OR APPROVED EQUAL FOR EMERGENCY FIXTURE OPERATION. NATATORIUM LIGHTING FIXTURE AND ALL ASSOCIATED HOUSING, HARDWARE, AND COMPONENTS EXPOSED TO ENVIRONMENT SHALL BE PROVIDED WITH NATATORIUM RATED FINISH SUITABLE FOR INTENDED USE IN CORROSIVE NATATORIUM ENVIRONMENT. MANUFACTURER SHALL PROVIDE 10-YEAR WARRANTY ON ENTIRE FIXTURE INCLUDING LED DRIVER AND BOARDS FOR USE IN NATATORIUM.. AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 1 : 1 9 : 5 9 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R VRP, ESN TPK, KM 10-31-2016 16003 ELECTRICAL SCHEDULES E501 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOGUE NUMBER VOLTAGE LAM P QUA N. LAMP WATTAGE LAMP MAX WATTAGE DIMMING LOCATION BOF/RFD/ OFH NOTES W1 DECORATIVE OIL RUBBED BRONZE VANITY FIXTURE EUROPHASE 23278-011 120V 3 5 W LED 15 VA NA SURFACE WALL W2 DECORATIVE OIL RUBBED BRONZE VANITY FIXTURE EUROPHASE 23277-014 120V 2 5 W LED 10 VA NA SURFACE WALL 3,9 W3EM 4' LINEAR WALL MOUNT D/I LED W/EM BATTERY HE WILLIAMS WMAUD-4-L32-835-AF-EM/1OW-DRV-UNV 277V 1 81 W LED 81 VA NA SURFACE WALL 10'-0"AFG 9 W4 4' LINEAR WALL MOUNT DIRECT/INDIRECT LED ALERA LIGHTING LP7-OA-4-35-ML-40-WM-E-U-MW 277V 1 44 W LED 44 VA NA SURFACE WALL X1 CAST ALUMINUM GREEN LED EXIT SIGN, UNIVERSAL MOUNT HE WILLIAMS EXIT/CA-G-AF-BA-EM-SDT 277V 1 4 W LED 4 VA NA SURFACE X2 CAST ALUMINUM GREEN LED EXIT SIGN, UNIVERSAL MOUNT W/ WIREGUARD HE WILLIAMS EXIT/CA-G-AF-BA-EM-SDT-WG 277V 1 4 W LED 4 VA NA SURFACE Y1 EMERGENCY EGRESS LIGHT HE WILLIAMS EMER/PAR-WHT-WG 277V 2 5 W LED 10 VA NA SURFACE WALL EA1 LED AREA POLE LIGHT, SINGLE HEAD TYPE III KIM LIGHTING 1A-AR3P70-80L4K 277V 1 187 W LED 187 VA POLE GROUND +25'-0" AFG EA2 LED AREA POLE LIGHT, SINGLE HEAD TYPE V KIM LIGHTING 1A-AR5P70-80L4K 277V 1 188 W LED 188 VA POLE GROUND +25'-0" AFG EB3 LED BOLLARD STERNBERG LIGHTING BL4-ML360-SV1-32L45T3R-F-MDL05-UBT 277V 1 39 W LED 39 VA GROUND +4'-0" AFG EB4 LED PIER BASE MOUNT STERNBERG LIGHTING PB-ML360-SV1-32L45T5-F-MDL03-UBT 277V 1 39 W LED 39 VA SURFACE +4'-0" AFG EP1 6" EXTERIOR LED CYLINDER PENDANT DOWNLIGHT CONTECH CYL6-2-35K-MVD-P-X-M-CLR-BZ-CSK12-(BZ) 277V 1 14 W LED 14 VA PENDANT CEILING 8 EP1EM 6" EXTERIOR LED CYLINDER PENDANT DOWNLIGHT W/ EM BATTERY CONTECH CYL6-2-35K-MVD-P-X-M-CLR-BZ-CSK12-(BZ); PROVIDE (1) BODINE ELI-S-100 EM LIGHTING INVERTER 277V 1 14 W LED 14 VA PENDANT CEILING 8 EP5 LED PEDESTRIAN POLE LIGHT, SINGLE HEAD, TYPE V STERNBERG LIGHTING PT-ML660-SV1-60L45T5-MDL03-UBT 277V 1 70 W LED 70 VA POLE GROUND +15'-0" AFG EST1 LED RECESSED STEP-LIGHT BEGA 22272 277V 1 7 W LED 7 VA RECESSED WALL +2' AFG 9 EW1 SMALL LED WALL SCONCE KIM LIGHTING 1W-BNM-18L3KUV-DB 277V 1 20 W LED 20 VA SURFACE WALL +8'-0" AFG 9 EW2 LARGE LED DECORATIVE WALL SCONCE KIM LIGHTING 1W-BNS1-H3-E35-60L-3K-277-DB 277V 1 64 W LED 64 VA SURFACE WALL +15'-0" AFG 9 EW2EM LARGE LED DECORATIVE WALL SCONCE KIM LIGHTING 1W -BNS1-H3-E35-60L-3K-277-DB; PROVIDE (1) BODINE ELI-S-100 EM LIGHTING INVERTER 277V 1 64 W LED 64 VA SURFACE WALL +15'-0" AFG EW3EM EXTERIOR LED WALLPACK HE WILLIAMS VWPV-L30-730-T3-DBZ-SDGL-EM/4W-DIM-UNV UNIV 1 37 W LED 37 VA SURFACE WALL +10'-0" AFG 9 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOGUE NUMBER VOLTAGE LAM P QUA N. LAMP WATTAGE LAMP MAX WATTAGE DIMMING LOCATION BOF/RFD/ OFH NOTES C1 LED TAPELIGHT & DRIVER(S) CONTECH TLT-12-2-35-XX; (2)TLP12VH60277 277V -- 2 W LED 84 VA TBD SURFACE 10 C2 LED COVE TAPELIGHT - COMMUNITY ROOM CONTECH TLT-12-2-35-XX; (1)TLP12VH60277; TLPDIM10V 277V -- 2 W LED 40 VA 0-10V SURFACE 10 C3 LED COVE TAPELIGHT - COMMUNITY ROOM CONTECH TLT-12-2-35-XX; (1)TLP12VH60277; TLPDIM10V 277V -- 2 W LED 36 VA 0-10V SURFACE 10 C4 LED COVE TAPELIGHT - COMMUNITY ROOM CONTECH TLT-12-2-35-XX; (1)TLP12VH60277; TLPDIM10V 277V -- 2 W LED 40 VA 0-10V SURFACE 10 CF1 52" BLADE FAN MODERN FAN CO FLO-XX-52-XX-NL-009B 120V -- 76 W -- 76 VA -- PENDANT CEILING 9'-11" BOF D1 6" LED DOWNLIGHT PRESCOLITE LBP6-6LBP-11L-35-WH UNIV 1 12 W LED 12 VA 0-10V RECESSED CEILING D1EM 6" LED DOWNLIGHT WITH REMOTE EMERGENCY BATTERY INVERTER PRESCOLITE LBP6-6LBP-11L-35-WH; PROVIDE ADDITIONAL $100 PER FIXTURE MATERIAL PRICING ALLOWANCE FOR EMERGENCY LIGHTING INVERTER UNIV 1 12 W LED 12 VA 0-10V RECESSED CEILING D2 4" LED DOWNLIGHT PRESCOLITE LF4LEDG4-4LFLED5G4-35K-WT-B24 277V 1 15 W LED 15 VA 0-10V RECESSED CEILING 1 D3 4" LED DOWNLIGHT WET LISTED WILA LIGHTING 621-4-XTM19-10LM-35K-83-DA60-120-10V-NC-WETD 120V 1 15 W LED 15 VA 0-10V RECESSED CEILING D4 6" LED RECESSED WALLWASHER DOWNLIGHT PRESCOLITE LBP6-6LBP-11L-35-WH-WW 277V 1 12 W LED 12 VA 0-10V RECESSED CEILING D5 6" LED RECESSED DOWNLIGHT, ADJUSTABLE SLOPED CEILING, 3500K PRESCOLITE LFA6LEDG4-6LFALED6G4-35K-WFL45-6C3-SS-WT-B 24 277V 1 21 W LED 21 VA 0-10V RECESSED CEILING 7-5/8" RFD D5EM 6" LED RECESSED DOWNLIGHT, ADJUSTABLE SLOPED CEILING, 3500K, EM INVERTER PRESCOLITE LFA6LEDG4-6LFALED6G4-35K-WFL45-6C3-SS-WT-B 24-LPS SERIES; PROVIDE ADDITIONAL $100 PER FIXTURE MATERIAL PRICING ALLOWANCE FOR EMERGENCY LIGHTING INVERTER 277V 1 21 W LED 21 VA 0-10V RECESSED CEILING 7-5/8" RFD 11 D6 6" LED DOWNLIGHT, LEVEL GRID CEILING PRESCOLITE LF6LEDG4-6LFLED5G4-35K-WT-B24 277V 1 21 W LED 21 VA 0-10V RECESSED CEILING 7-5/8" RFD D6EM 6" LED DOWNLIGHT, LEVEL GRID CEILING, INTEGRAL EM BATTERY PRESCOLITE LF6LEDG4-6LFLED5G4-35K-WT-B24-EM 277V 1 21 W LED 21 VA 0-10V RECESSED CEILING 7-5/8" RFD 11 D7 6" HIGH-ABUSE LED DOWNLIGHT FOR NATATORIUM APPLICATION KENALL HRDL6L-19L-35K8-DV-DCC-FW-CSS-TTG UNIV 1 19 W LED 19 VA 0-10V RECESSED CEILING 6.95" RFD D7EM 6" HIGH-ABUSE LED DOWNLIGHT FOR NATATORIUM APPLICATION W/ EM BATTERY KENALL HRDL6L-19L-35K8-DV-DCC-FW-CSS-TTG-LEL UNIV 1 19 W LED 19 VA 0-10V RECESSED CEILING 6.95" RFD F1 4'-0" LED LENSED STRIPLIGHT COLUMBIA LIGHTING LCL-4-35-ML-E-U-S18 UNIV 1 53 W LED 53 VA NA PENDANT CEILING F2 8'-0" LED LENSED STRIPLIGHT COLUMBIA LIGHTING LCL-8-35-ML-E-U-S18 UNIV 1 106 W LED 106 VA NA PENDANT CEILING F3 4'-0" LED ENCLOSED & GASKETED STRIP COLUMBIA LIGHTING LXEN-4-35-LW-RFA-E-U-XEHC UNIV 1 37 W LED 37 VA NA PENDANT CEILING H1 LED GYM HIGH-BAY LUX DYNAMICS LED-GYM-4-UNV-835-HO-LPDW-4'-CUSTOM 277V 1 356 W LED 356 VA 0-10V PENDANT CEILING 2,8 H1EM LED GYM HIGH-BAY, EMERGENCY BATTERY LUX DYNAMICS LED-GYM-4-UNV-835-HO-EM-LPDW-4'-CUSTOM 277V 1 356 W LED 356 VA 0-10V PENDANT CEILING 2,8 H2 LED NATATORIUM ARCHITECTURAL HIGH-BAY LUX DYNAMICS LED-WAVE-3-UNV-TOP-835-(2)HO-(1)SO-H4P10-LA DW-4'-NAT 277V 1 226 W LED 226 VA 0-10V PENDANT CEILING 4,8 H2EM LED NATATORIUM ARCHITECTURAL HIGH-BAY, EMERGENCY LUX DYNAMICS LED-WAVE-3-UNV-TOP-835-(2)HO-(1)SO-EM-H4P10- LADW-4'-NAT 277V 1 226 W LED 226 VA 0-10V PENDANT CEILING 4,8 L1A LED SUSPENDED LINEAR WAVE CONVEX BARBICAN 19-4W-3H-CC-16-144R-LF-221-ACW-MFM-SDL-WHT- 6WLF-277V-3500K-80CRI-DB0-10V 277V 1 75 W LED 75 VA 0-10V SUSPENDED CEILING 12'-0" AFF L1B LED SUSPENDED LINEAR WAVE CONCAVE BARBICAN 19-4W-3H-CV-16-144R-LF-221-ACW-MFM-SDL-WHT- 6WLF-277V-3500K-80CRI-DB0-10V 277V 1 75 W LED 75 VA 0-10V SUSPENDED CEILING 12'-0" AFF L2 LED SUSPENDED LINEAR D/I ALERA LIGHTING LP7-OA-12-35-ML-40-CM-24-ED-U-ZT 277V 1 132 W LED 132 VA 0-10V SUSPENDED CEILING L4 4' LED WALL-GRAZE, CABLE MOUNT SUSPENSION AIMED DOWNWARD TOWARD WALL INSIGHT LIGHTING MC-6-35K-15-D-PNS-X-48"-REM-NO-BL; C1/100/PWR/277 277V 1 36 W LED 36 VA NA SUSPENDED CEILING 9 P1 6" LED CYLINDER PENDANT DOWNLIGHT CONTECH CYL6-2-35K-MVD-CF-P-CLR 277V 1 14 W LED 14 VA 0-10V PENDANT CEILING 8 P1EM 6" LED CYLINDER PENDANT DOWNLIGHT, W/ INTEGRAL EM BATTERY CONTECH CYL6-2-35K-MVD-CF-P-CLR; PROVIDE (3) BODINE ELI-S-100 EM INVERTERS 277V 1 14 W LED 14 VA 0-10V PENDANT CEILING 8 P3 17" LED PENDANT, FROSTED LENS LOWBAY DELRAY LIGHTING IL7800-750-W35-2 277V 1 50 W LED 50 VA 0-10V PENDANT CEILING P3EM 17" LED PENDANT, FROSTED LENS LOWBAY, W/ EM BATTERY PACK DELRAY LIGHTING IL7800-750-W35-2-EM 277V 1 50 W LED 50 VA 0-10V PENDANT CEILING P4 6" LED CYLINDER PENDANT DOWNLIGHT, CUSTOM COLOR FINISH CONTECH CYL6-2-35K-MVD-CF-P-CLR-CUSTOM COLOR 277V 1 14 W LED 14 VA 0-10V PENDANT CEILING 13'-0" BOF 8 P5 DECORATIVE INDUSTRIAL PENDANT HUBBARDTON FORGE 161065-82-ZM349 12V 1 50 W T4 INC 50 VA NA PENDANT CEILING P6 DECORATIVE INDUSTRIAL RLM PENDANT BARN LIGHT ELECTRIC C-WHS18-PC-615-SBK-100-WG-615-LED-1250D-300 0K-120V-277V-0-10V 277V 1 48 W LED 48 VA 0-10V PENDANT CEILING P7 LARGE SCALE DECORATIVE LOBBY PENDANT EVERGREEN DBL-CYLP35X24-2MED-9-HO-MSH 277V 1 120 W TBD 120 VA TBD PENDANT CEILING P8 LARGE 5' DECORATIVE DRUM PENDANT LUMETTA P56017-F3-D865-LED6-277-CXX3 277V 6 19 W LED 113 VA 0-10V PENDANT CEILING 8 P9 SMALL 3' DECORATIVE DRUM PENDANT LUMETTA P53414-F3-D865-LED3-277-CXX3 277V 3 19 W LED 57 VA 0-10V PENDANT CEILING 8 R1 2X4 LED D/I TROFFER HE WILLIAMS AT1-24-L55-835-D-DRV-UNV 277V 1 59 W LED 59 VA NA RECESSED CEILING R2 2X2 LED D/I TROFFER HE WILLIAMS AT1-22-L30-835-D-DRV-UNV 277V 1 31 W LED 31 VA NA RECESSED CEILING R2EM 2X2 LED D/I TROFFER W/ INTEGRAL EM BATTERY HE WILLIAMS AT1-22-L30-835-D-EM/10W-DRV-UNV 277V 1 31 W LED 31 VA NA RECESSED CEILING R3 2x2 RECESSED 1" DROP LENS FIXTURE 3G LIGHTING 3G-RKU2401-L2-30K-277-DIM-GC1-DD1 277V 1 31 W LED 28 VA 0-10V RECESSED CEILING R4 2x2 RECESSED 2" DROP LENS FIXTURE 3G LIGHTING 3G-RKU2401-L2-30K-277-DIM-GC1-DD2 277V 1 28 W LED 28 VA 0-10V RECESSED CEILING R5 2x2 RECESSED 3" DROP LENS FIXTURE 3G LIGHTING 3G-RKU2401-L2-30K-277-DIM-GC1-DD3 277V 1 28 W LED 28 VA 0-10V RECESSED CEILING R6 2X2 RECESSED 4" DROP LENS FIXTURE 3G LIGHTING 3G-RKU2401-L2-30K-277-DIM-GC1-DD4 277V 1 28 W LED 28 VA 0-10V RECESSED CEILING R7 2X2 RECESSED 5" DROP LENS FIXTURE 3G LIGHTING 3G-RKU2401-L2-30K-277-DIM-GC1-DD5 277V 1 28 W LED 28 VA 0-10V RECESSED CEILING R8 2x2 FLUSH LENS FIXTURE FOCAL POINT 3G-RKU2401-L2-30K-277-DIM-GC1-FL 277V 1 31 W LED 31 VA 0-10V RECESSED CEILING R9 2'x4' LENSED LED TROFFER, WET RATED, GASKETED HE WILLIAMS 50G-S24-L35/835-F-AF12125-DRV-277 277V 1 34 W LED 34 VA 0-10V RECESSED CEILING R10 2' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-2'-B-8-35-F-120V-SC-C1 120V 1 9 W LED 9 VA 0-10V RECESSED CEILING R11 4' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-4'-B-8-35-F-120V-SC-C1 120V 1 18 W LED 18 VA 0-10V RECESSED CEILING R12 6' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-6'-B-8-35-F-120V-SC-C1 120V 1 28 W LED 28 VA 0-10V RECESSED CEILING R12EM 6' LINEAR RECESSED LED SLOT FIXTURE, W/ EM BATTERY FINELITE HP-4-R-6'-B-8-35-F-120V-SC-C1-EM BATTERY 120V 1 28 W LED 28 VA 0-10V RECESSED CEILING R13 8' LINEAR RECESSED LED SLOT FIXTURE (120V) FINELITE HP-4-R-8'-B-8-35-F-120V-SC-C18 120V 1 37 W LED 37 VA 0-10V RECESSED CEILING R13A 8' LINEAR RECESSED LED SLOT FIXTURE (277V) FINELITE HP-4-R-8'-B-8-35-F-277V-SC-C18 277V 1 37 W LED 37 VA 0-10V RECESSED CEILING R13EM 8' LINEAR RECESSED LED SLOT FIXTURE, W/ EM BATTERY FINELITE HP-4-R-8'-B-8-35-F-120V-SC-C1-EM BATTERY 120V 1 37 W LED 37 VA 0-10V RECESSED CEILING R14 10' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-10'-B-8-35-F-120V-SC-C1 120V 1 46 W LED 46 VA 0-10V RECESSED CEILING R15 15' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-15'-B-8-35-F-120V-SC-C1 120V 1 69 W LED 69 VA 0-10V RECESSED CEILING R15A 15' LINEAR RECESSED LED SLOT FIXTURE (277V) FINELITE HP-4-R-15'-B-8-35-F-277V-SC-C1 277V 1 69 W LED 69 VA 0-10V RECESSED CEILING R15EM 15' LINEAR RECESSED LED SLOT FIXTURE, W/ EM BATTERY FINELITE HP-4-R-15'-B-8-35-F-120V-SC-C1-EM BATTERY 120V 1 69 W LED 69 VA 0-10V RECESSED CEILING R16 16' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-16'-B-8-35-F-120V-SC-C1 120V 1 74 W LED 74 VA 0-10V RECESSED CEILING R16A 16' LINEAR RECESSED LED SLOT FIXTURE (277V) FINELITE HP-4-R-16'-B-8-35-F-277V-SC-C1 277V 1 74 W LED 74 VA 0-10V RECESSED CEILING R20 20' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-20'-B-8-35-F-277V-SC-C1 277V 1 92 W LED 92 VA 0-10V RECESSED CEILING R20EM 20' LINEAR RECESSED LED SLOT FIXTURE, W/ EM BATTERY FINELITE HP-4-R-20'-B-8-35-F-277V-SC-C1-EM BATTERY 277V 1 92 W LED 92 VA 0-10V RECESSED CEILING R22 22' LINEAR RECESSED LED SLOT FIXTURE FINELITE HP-4-R-22'-B-8-35-F-277V-SC-C1 277V 1 101 W LED 101 VA 0-10V RECESSED CEILING R22EM 22' LINEAR RECESSED LED SLOT FIXTURE, W/ EM BATTERY FINELITE HP-4-R-22'-B-8-35-F-277V-SC-C1-EM BATTERY 277V 1 101 W LED 101 VA 0-10V RECESSED CEILING RG1 11' CONTINOUS RECESSED LINEAR LED SLOT FIXTURE W/ MITERED CORNER FINELITE HP-4-R-11'-B-8-35-F-120V-FA-SC-C4 120V 1 51 W LED 51 VA 0-10V RECESSED CEILING RG4 4' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-4'-B-8-35-F-120V-C1 120V 1 18 W LED 18 VA 0-10V RECESSED CEILING RG6 6' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-6'-B-8-35-F-120V-C1 120V 1 28 W LED 28 VA 0-10V RECESSED CEILING RG8 8' LED RECESSED LINEAR REGRESSED LENS FINELITE HP-4-RG-8'-B-8-35-F-120V-C1 120V 1 37 W LED 37 VA 0-10V RECESSED CEILING RG10 10' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-10'-B-8-35-F-120V-C1 120V 1 46 W LED 46 VA 0-10V RECESSED CEILING RG12 12' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-12'-B-8-35-F-120V-C1 120V 1 55 W LED 55 VA 0-10V RECESSED CEILING RG14 14' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-14'-B-8-35-F-120V-C1 120V 1 64 W LED 64 VA 0-10V RECESSED CEILING RG15 15' LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-15'-B-8-35-F-120V-C1 120V 1 69 W LED 69 VA 0-10V RECESSED CEILING RG87 8'-7" LED RECESSED LINEAR, REGRESSED LENS FINELITE HP-4-RG-8'-7"-B-8-35-F-120V-C1 120V 1 41 W LED 41 VA 0-10V RECESSED CEILING RM1 RECESSED MULTIPLE, SINGLE HEAD LED 3G LIGHTING 3G-RC2LED-10-S-30K-40D-277V-DIM-BT-BG-BK 277V 1 10 W LED 10 VA 0-10V RECESSED CEILING RM2 RECESSED MULTIPLE, DOUBLE HEAD LED 3G LIGHTING 3G-RC1LED-10-S-30K-40D-277V-DIM-BT-BG-BK 277V 2 10 W LED 20 VA 0-10V RECESSED CEILING T1 6'-0" LED TRACK CONTECH CTL-8070-F-35-D-P; LT-6-P 120V 4 9 W LED 36 VA MLV SUSPENDED CEILING 12'-0" BOF 9 T2 6'-0" LED TRACK CONTECH CTL-8070-F-35-D-P; LT-6-P 120V 4 9 W LED 36 VA MLV SUSPENDED CEILING UC1 UNDERCABINET LED TAPELIGHT PRIMUS LIGHTING ALX4-SP-LED-35K-12-R-IM-W-X' 120V 1 3 W LED NA SURFACE 10 AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 10 / 3 1 / 2 0 1 6 1 1 : 2 0 : 0 6 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 ELECTRICAL SCHEDULES E502 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NOTES: KITCH EQUIP:TOTAL EST. DEMAND:158 A EQUIPMENT:10020 VA 10020 VA TOTAL CONN.:145 A MOTOR:108447 VA 118805 VA TOTAL EST. LOAD:131001 VA RECEPTACLE:1080 VA 1080 VA TOTAL CONN. LOAD:120424 VA LIGHTING:877 VA 1096 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:148 A 145 A 143 A Total Load:40813 VA 40071 VA 39501 VA 41 -- BUSSED SPACE -- --0 4920 -- -- ---- 42 39 -- BUSSED SPACE -- -- 0 5076 -- -- ---- 40 37 -- BUSSED SPACE -- -- 0 5908 3 45 PANEL 'LA2A' VIA TAA L; E; ... 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 26 23 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 24 21 L L 20 1 414 0 -- -- BUSSED SPACE -- 22 19 L NATATORIUM FOYER AND ENTRY LIGHTING 20 1 324 0 -- -- BUSSED SPACE -- 20 17 -- ---- --13810 0 1 20 SPARE -- 18 15 -- ---- -- 13810 0 1 20 SPARE -- 16 13 M LEISURE CURRENT PUMP #2 (CP-2) 90 3 13810 0 1 20 SPARE -- 14 11 -- ---- --2923 13810 -- -- ---- 12 9 -- ---- -- 2923 13810 -- -- ---- 10 7 M LEISURE CIRCULATION PUMP (LCP-1) 20 3 2923 13810 3 90 LEISURE CURRENT PUMP #1 (CP-1) M 8 5 -- ---- --2019 2019 -- -- ---- 6 3 -- ---- -- 2019 2019 -- -- ---- 4 1 M LEISURE AMENITY PUMP #1 (LAP-1) 15 3 2019 2019 3 15 LEISURE AMENITY PUMP #2 (LAP-2) M 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 254 VOLTS:480/277 Wye A.I.C. RATING:42,000 AIC PANEL: HA2A NOTES: KITCH EQUIP:TOTAL EST. DEMAND:45 A EQUIPMENT:10020 VA 10020 VA TOTAL CONN.:44 A MOTOR:4704 VA 4998 VA TOTAL EST. LOAD:16223 VA RECEPTACLE:1080 VA 1080 VA TOTAL CONN. LOAD:15904 VA LIGHTING:100 VA 125 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:49 A 43 A 41 A Total Load:5908 VA 5076 VA 4920 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 26 23 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 24 21 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 22 19 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 20 17 -- SPARE 20 1 0 0 1 20 SPARE -- 18 15 L CHLORINATOR - EXISTING POOL (ECH-3) 20 1 100 0 1 20 SPARE -- 16 13 R RECPTS - POOL MECH RM 20 1 1080 100 1 20 SE-1 AND SE-2 CONTROL PANEL E 14 11 E PPG CHLORINATOR (CH-1) 20 1 1800 1200 1 20 CLEAR COMFORT SUPP TREATMENT (CCS-1) E 12 9 M CHEM CAB EXHAUST BLOWER #2 (CCEB-2) 20 1 1176 200 1 20 AUTO FILL CONTROLLERS E 10 7 E CHEMICAL CONTROLLER (CC-1) 20 1 1200 1176 1 20 CHEM CAB EXHAUST BLOWER #1 (CCEB-1) M 8 5 E LEISURE POOL HEATER (LH-1) 20 1 1800 120 1 20 ACID PUMP (AP-1) E 6 3 E DEFENDER FILTER CONTROLLER (FC-1) 20 1 1800 1800 1 20 DEFENDER FILTER AIR COMPRESSOR (AC-1) E 4 1 M CLEAR COMFORT BOOSTER PUMP #1... 20 1 1176 1176 1 20 SEWAGE EJECTOR PUMP (SE-1,2) M 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:100 A MOUNTING:SURFACE WIRES:4 MAINS RATING:100 A SUPPLY FROM:TAA PHASES:3 MAINS TYPE:MCB LOCATION:ELEC 254 VOLTS:120/208 Wye A.I.C. RATING:22,000 AIC PANEL: LA2A (*) PROVIDE GFCI PROTECTED CIRCUIT BREAKER. NOTES: KITCH EQUIP:TOTAL EST. DEMAND:205 A EQUIPMENT:16716 VA 16716 VA TOTAL CONN.:206 A MOTOR:37995 VA 38715 VA TOTAL EST. LOAD:73866 VA RECEPTACLE:14760 VA 12380 VA TOTAL CONN. LOAD:74315 VA LIGHTING:4844 VA 6055 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:195 A 210 A 227 A Total Load:23388 VA 24945 VA 26982 VA 83 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 84 81 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 82 79 L LIGHTING RESTROOMS 20 1 734 0 -- -- BUSSED SPACE -- 80 77 L (*)LIGHTING WOMENS LOCK. & FAM.... 20 1 1559 1000 1 20 HAND DRYER - FAM CHANGING M 78 75 -- ---- -- 832 1000 1 20 HAND DRYER - FAM CHANGING M 76 73 M EF-17 15 2 832 1000 1 20 HAND DRYER - W TOILET 223 M 74 71 -- ---- --920 1000 1 20 HAND DRYER - M TOILETS 233 M 72 69 M EF-2 30 2 920 1500 1 20 FIRE ACCORDIAN DOOR SYSTEM M 70 67 E (*) POOL VACUUM 30 1 1400 500 1 20 VAV CONTROLS TRANSFORMER E 68 65 R RECPTS - POOL AREA, EXTERIOR 20 1 900 1260 1 20 RECPTS - POOL AREA, EXTERIOR R 66 63 R RECPTS - CIRC, FOYER, CUARD CHG 20 1 540 720 1 20 RECPTS - POOL OFFICE R 64 61 E MICROWAVE - GUARDS ROOM 20 1 1000 1000 1 20 REFRIGERATOR - GUARDS ROOM E 62 59 R RECPTS - GUARDS ROOM 20 1 1440 1400 1 30 (*) POOL VACUUM E 60 57 M (*) SUIT SPINNER 20 1 1600 1600 1 30 (*) POOL VACUUM E 58 55 E EWC - MENS LOCKER 20 1 500 900 1 20 RECPTS - MENS LOCKER, MECH A102 R 56 53 -- ---- --1440 360 1 20 AC RECPTS - MENS LOCKER R 54 51 M HAIR DRYER - MENS LOCKER 20 2 1440 1000 1 20 HAND DRYER - MENS LOCKER M 52 49 -- ---- -- 1440 1440 -- -- ---- 50 47 M HAIR DRYER - MENS LOCKER 20 2 1440 1440 2 20 HAIR DRYER - WOMENS LOCKER M 48 45 R RECPTS - WOMENS LOCKER 20 1 900 500 1 20 EWC - WOMENS LOCKER E 46 43 R AC RECPTS - WOMENS LOCKER 20 1 360 360 1 20 AC RECPTS - WOMENS LOCKER R 44 41 M HAND DRYER - WOMENS LOCKER 30 1 1000 1000 1 30 HAND DRYER - WOMENS LOCKER M 42 39 M HAND DRYER - MENS LOCKER 30 1 1000 1440 -- -- ---- 40 37 R RECPTS - FAMILY CHANGING 20 1 1080 1440 2 20 HAIR DRYER - WOMENS LOCKER M 38 35 L (*)LIGHTING MENS LOCKERS 231 20 1 1351 1080 1 20 RECPTS - ROOM 206, 207, 229 R 36 33 R RECPTS - KID WATCH 20 1 900 1200 1 20 (*) POOL LIGHTS L 34 31 R RECEPTS - ROOM 202, 211, 201 20 1 720 1080 1 20 RECPTS - INDOOR PLAY R 32 29 M MOTORIZED DOOR OPENER - VESTIBULE 201 30 1 1000 1000 1 20 MOTORIZED DOOR OPENER - VESTIBULE 201 M 30 27 E MICROWAVE - PARTY ROOM 20 1 1000 1000 1 20 REFRIGERATOR - PARTY ROOM E 28 25 M DISPOSAL - PARTY ROOM 20 1 1176 360 1 20 AC RECPTS - PARTY ROOM R 26 23 R RECPTS - ROOF 20 1 720 1080 1 20 RECPTS - ROOF R 24 21 E HEAT TRACE 20 1 400 350 1 20 HEAT TRACE E 22 19 M EF-5 15 1 696 1656 1 25 EF-14 M 20 17 E UH-6 20 1 96 696 1 15 EF-4 M 18 15 M EF-1 15 1 696 832 -- -- ---- 16 13 E; M UH-1, UH-2, UH-3, CUH-1, CUH-2 15 1 826 832 2 25 EF-6 M 14 11 E GWH-1, GWH-2, GWH-3 15 1 720 200 1 20 TEMPERATURE CONTROL PANEL E 12 9 M CP-3 15 1 528 1176 1 20 PP-1 M 10 7 M CP-1 15 1 528 528 1 15 CP-2 M 8 5 E B-2 15 1 1440 1440 1 20 B-3 E 6 3 M EF-3, TF-3 15 1 431 1440 1 15 B-1 E 4 1 E RP2A 20 1 500 500 1 20 FACP E 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:250 A MOUNTING:SURFACE WIRES:4 MAINS RATING:400 A SUPPLY FROM:TPA PHASES:3 MAINS TYPE:MCB LOCATION:ELEC 254 VOLTS:120/208 Wye A.I.C. RATING:42,000 AIC PANEL: LP2A (*) ELECTRICAL EQUIPMENT INDICATED AND ASSOCIATED W ITH THIS SCOPE OF WORK SHALL BE SEPERATELY PRICED AS PART OF ALTERNATE #2. NOTES: KITCH EQUIP:TOTAL EST. DEMAND:83 A EQUIPMENT:TOTAL CONN.:76 A MOTOR:62930 VA 69407 VA TOTAL EST. LOAD:69407 VA RECEPTACLE:TOTAL CONN. LOAD:62930 VA LIGHTING: CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:76 A 76 A 76 A Total Load:20977 VA 20977 VA 20977 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- CF-4A SHUNT TRIP -- -- 0 0 -- -- CF-5A SHUNT TRIP -- 28 25 -- ---- -- 283 283 -- -- ---- 26 23 -- ---- --283 283 -- -- ---- 24 21 M CF-4A 15 3 283 283 3 15 CF-5A M 22 19 -- SPARE 20 1 0 0 -- -- CF-3 SHUNT TRIP -- 20 17 -- ---- --1175 300 -- -- ---- 18 15 -- ---- -- 1175 300 -- -- ---- 16 13 M MAU-1 15 3 1175 300 3 15 CF-3 M 14 11 -- ---- --831 8636 -- -- ---- 12 9 -- ---- -- 831 8636 -- -- ---- 10 7 M P-2 15 3 831 8636 3 50 PDU-1A (*)M 8 5 -- ---- --831 8636 -- -- ---- 6 3 -- ---- -- 831 8636 -- -- ---- 4 1 M P-1 20 3 831 8636 3 40 PDU-2 M 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 254 VOLTS:480/277 Wye A.I.C. RATING:42,000 AIC PANEL: HM2A AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 10 / 3 1 / 2 0 1 6 1 1 : 2 0 : 1 2 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 ELECTRICAL SCHEDULES E503 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NOTES: KITCH EQUIP:TOTAL EST. DEMAND:101 A EQUIPMENT:48305 VA 48305 VA TOTAL CONN.:111 A MOTOR:16940 VA 17208 VA TOTAL EST. LOAD:84185 VA RECEPTACLE:26640 VA 18320 VA TOTAL CONN. LOAD:92167 VA LIGHTING:282 VA 353 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:115 A 112 A 107 A Total Load:31738 VA 30928 VA 29501 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 26 23 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 24 21 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 22 19 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 20 17 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 18 15 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 16 13 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 14 11 -- SPARE 20 1 0 6440 -- -- ---- 12 9 -- SPARE 20 1 0 6440 -- -- ---- 10 7 -- CF-1, CF-2 SHUNT TRIP -- -- 0 9120 3 45 TBT E; R 8 5 -- ---- --713 22348 -- -- ---- 6 3 -- ---- -- 713 23775 -- -- ---- 4 1 M CF-1, CF-2 15 3 713 21905 3 175 T2B L; E; ... 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 282 VOLTS:480/277 Wye A.I.C. RATING:65,000 AIC PANEL: HM2B NOTES: KITCH EQUIP:TOTAL EST. DEMAND:173 A EQUIPMENT:30805 VA 30805 VA TOTAL CONN.:189 A MOTOR:14800 VA 15050 VA TOTAL EST. LOAD:62278 VA RECEPTACLE:22140 VA 16070 VA TOTAL CONN. LOAD:68027 VA LIGHTING:282 VA 353 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:183 A 199 A 187 A Total Load:21905 VA 23775 VA 22348 VA 125 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 126 123 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 124 121 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 122 119 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 120 117 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 118 115 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 116 113 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 114 111 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 112 109 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 110 107 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 108 105 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 106 103 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 104 101 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 102 99 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 100 97 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 98 95 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 96 93 -- SPARE 20 1 0 0 1 20 SPARE -- 94 91 -- SPARE 20 1 0 0 1 20 SPARE -- 92 89 -- SPARE 20 1 0 0 1 20 SPARE -- 90 87 E IRRIGATION CONTROLLER 20 1 500 0 1 20 SPARE -- 88 85 E VAV CONTROLS TRANSFORMER 20 1 500 500 1 20 FIRE SMOKE DAMPER E 86 83 R RECPTS - EXTERIOR SERPENTINE WALL 20 1 900 72 1 20 LOBBY LIGHTING L 84 81 M HAND DRYER - W TEAM LOCKER 20 1 1000 900 1 20 RECPTS - PARKING LOT R 82 79 R RECPTS - W TEAM LOCKER 20 1 360 540 1 20 RECPTS - W TEAM LOCKER, EXTERIOR R 80 77 R RECPTS - POOL STORAGE, M TEAM LOCKER 20 1 900 1000 1 20 HAND DRYER - M TEAM LOCKER M 78 75 R RECEPTS - LOBBY 20 1 900 200 1 20 DOOR HOLD - VESTIBULE A104 E 76 73 R AC RECPTS - COPY 278 20 1 540 900 1 20 RECEPTS - POOL, PARTY ROOM R 74 71 R RECPTS - LAP TRACK 20 1 1440 360 1 20 RECPTS - TRACK R 72 69 R RECPTS - LOBBY FRONT DESK 20 1 1080 540 1 20 RECPTS - ROOM 123, 202 R 70 67 M GYM DIVIDER CURTAIN 20 1 800 200 1 20 LAP TIMER E 68 65 M VOLLEYBALL SLEEVE NORTH 20 1 800 800 1 20 VOLLEYBALL SLEEVE SOUTH M 66 63 M BASKETBALL LIFT SOUTH 20 1 800 800 1 20 BASKETBAL LIFT SOUTHWEST M 64 61 M BASKETBALL LIFT NORTHEAST 20 1 800 800 1 20 BASKETBALL LIFT SOUTHEAST M 62 59 M BASKETBALL LIFT NORTHWEST 20 1 800 800 1 20 BASKETBALL LIFT NORTH M 60 57 R RECPTS - CARDIO, GROUP EX 20 1 1080 1260 1 20 RECPTS - GROUP EX R 58 55 E FLOOR BOX - CARDIO 20 1 750 500 1 20 EWC - CARDIO E 56 53 E FLOOR BOX - CARDIO 20 1 750 750 1 20 FLOOR BOX - CARDIO E 54 51 R RECPTS - ROOM 203, 204, 273, LOBBY 20 1 900 750 1 20 FLOOR BOX - CARDIO E 52 49 R RECPTS - ROOM 278, 282 20 1 1080 540 1 20 RECPTS - DESK STAFF R 50 47 R AC RECPTS - ADMIN 271 20 1 540 1000 1 20 COPIER - ROOM 278 E 48 45 E PROJECTOR - CONFERENCE 275 20 1 1000 500 1 20 MOTORIZED SCREEN - CONFERENCE 275 M 46 43 E MICROWAVE - CONFERENCE 275 20 1 1000 180 1 20 AC RECPT - CONFERENCE 275 R 44 41 R RECPTS - CONFERENCE 275 20 1 1080 1000 1 20 REFRIGERATOR - CONFERENCE 275 E 42 39 R RECPTS - EXEC DIR 281 20 1 1260 1080 1 20 RECPTS - ROOM 279, 277 R 40 37 R RECPTS - FINANCE 287 20 1 1080 1440 1 20 RECPTS - ROOM 285, 283 R 38 35 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 36 33 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 34 31 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 32 29 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 30 27 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 28 25 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 26 23 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 24 21 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 22 19 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 20 17 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 18 15 E FITNESS EQUIPMENT 20 1 750 750 1 20 FITNESS EQUIPMENT E 16 13 R RECPTS - ROOF 20 1 540 720 1 20 RECPTS - ROOF R 14 11 E HEAT TRACE 20 1 1460 200 1 20 HEAT TRACE E 12 9 M EF-12 15 1 696 696 1 15 EF-15 M 10 7 M EF-10 15 1 696 696 1 15 EF-11 M 8 5 M CEILING FANS M/P GROUP EX 262 20 1 1000 696 1 15 EF-9 M 6 3 L LIGHTING RESTROOMS 203, 204 20 1 210 1623 -- -- ---- 4 1 M EF-7, EF-8, TF-1 15 1 620 1623 2 20 DSCU-1 E 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:400 A MOUNTING:SURFACE WIRES:4 MAINS RATING:400 A SUPPLY FROM:T2B PHASES:3 MAINS TYPE:MCB LOCATION:ELEC 282 VOLTS:120/208 Wye A.I.C. RATING:22,000 AIC PANEL: LP2B NOTES: KITCH EQUIP:TOTAL EST. DEMAND:37 A EQUIPMENT:TOTAL CONN.:30 A MOTOR:TOTAL EST. LOAD:31005 VA RECEPTACLE:TOTAL CONN. LOAD:24804 VA LIGHTING:24804 VA 31005 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:31 A 41 A 18 A Total Load:8186 VA 10822 VA 5084 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- SPARE 20 1 0 0 1 20 SPARE -- 30 27 -- SPARE 20 1 0 0 1 20 SPARE -- 28 25 -- SPARE 20 1 0 0 1 20 SPARE -- 26 23 -- SPARE 20 1 0 53 1 20 LIGHTING ELEVATOR SHAFT L 24 21 -- SPARE 20 1 0 2061 1 20 LIGHTING EXTERIOR SITE AREA L 22 19 -- SPARE 20 1 0 1083 1 20 LIGHTING EXTERIOR PEDESTRIAN &... L 20 17 L LIGHTING NATATORIUM EAST 20 1 1582 1437 1 20 LIGHTING EQUIP RMS, GUARDS L 18 15 L LIGHTING NATATORIUM NORTHEAST 20 1 2524 1808 1 20 LIGHTING NATATORIUM SOUTH L 16 13 L LIGHTING INDOOR PLAY 20 1 534 0 1 20 SPARE -- 14 11 L LIGHTING SOUTH GYM EMERGENCY 20 1 1068 683 1 20 LIGHTING M/P GROUP EX 262 L 12 9 L LIGHTING NORTH GYM 131 20 1 1068 2492 1 20 LIGHTING SOUTH GYM L 10 7 L LIGHTING ABOVE TRACK 20 1 1945 2492 1 20 LIGHTING NORTH GYM 131 L 8 5 -- SPARE 20 1 0 261 1 20 LIGHTING EXIT STAIR 133 L 6 3 -- SPARE 20 1 0 869 1 20 LIGHTING LOBBY L 4 1 -- SPARE 20 1 0 2133 1 20 LIGHTING CONFERENCE/OFFICES L 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 282 VOLTS:480/277 Wye A.I.C. RATING:22,000 AIC PANEL: HL2B AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 10 / 3 1 / 2 0 1 6 1 1 : 2 0 : 1 8 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 ELECTRICAL SCHEDULES E504 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NOTES: KITCH EQUIP:TOTAL EST. DEMAND:74 A EQUIPMENT:27411 VA 27411 VA TOTAL CONN.:86 A MOTOR:11682 VA 12270 VA TOTAL EST. LOAD:61421 VA RECEPTACLE:32040 VA 21020 VA TOTAL CONN. LOAD:71709 VA LIGHTING:576 VA 720 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:97 A 85 A 79 A Total Load:26762 VA 23189 VA 21758 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 26 23 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 24 21 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 22 19 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 20 17 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 18 15 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 16 13 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 14 11 -- SPARE 20 1 0 0 1 20 SPARE -- 12 9 -- SPARE 20 1 0 0 1 20 SPARE -- 10 7 -- SPARE 20 1 0 0 1 20 SPARE -- 8 5 -- ---- --19678 2080 -- -- ---- 6 3 -- ---- -- 17849 5340 -- -- ---- 4 1 L; E; ... T1B 175 3 20598 6164 3 45 T1K E; R; M 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 109 VOLTS:480/277 Wye A.I.C. RATING:65,000 AIC PANEL: HM1B NOTES: KITCH EQUIP:TOTAL EST. DEMAND:12 A EQUIPMENT:TOTAL CONN.:10 A MOTOR:TOTAL EST. LOAD:10240 VA RECEPTACLE:TOTAL CONN. LOAD:8192 VA LIGHTING:8192 VA 10240 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:16 A 4 A 8 A Total Load:4316 VA 978 VA 2135 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- SPARE 20 1 0 0 1 20 SPARE -- 26 23 -- SPARE 20 1 0 0 1 20 SPARE -- 24 21 -- SPARE 20 1 0 0 1 20 SPARE -- 22 19 -- SPARE 20 1 0 0 1 20 SPARE -- 20 17 -- SPARE 20 1 0 0 1 20 SPARE -- 18 15 L LIGHTING GYM 131 20 1 300 252 1 20 LIGHTING L 16 13 L LIGHTING STRENGTH 20 1 1034 585 1 20 LIGHTING HP GROUP EX 124 L 14 11 L LIGHTING ROOMS 107, 111, 109, 105, 104, 106 20 1 1125 1010 1 20 LIGHTING RM 115, 116, 118, 113, 112, 122, 121 L 12 9 L LIGHTING RECEPTION DESK LOUNGE 102 20 1 84 342 1 20 LIGHTING COMMUNITY KITCHEN L 10 7 L LIGHTING LOUNGE 102 20 1 1075 1623 1 20 LIGHTING COMMUNITY ROOMS L 8 5 -- SPARE 20 1 0 0 1 20 SPARE -- 6 3 -- SPARE 20 1 0 0 1 20 SPARE -- 4 1 -- SPARE 20 1 0 0 1 20 SPARE -- 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING: MOUNTING:SURFACE WIRES:4 MAINS RATING:100 A SUPPLY FROM:MDC PHASES:3 MAINS TYPE:MLO LOCATION:ELEC 109 VOLTS:480/277 Wye A.I.C. RATING:22,000 AIC PANEL: HL1B NOTES: KITCH EQUIP:TOTAL EST. DEMAND:136 A EQUIPMENT:17915 VA 17915 VA TOTAL CONN.:161 A MOTOR:9754 VA 10342 VA TOTAL EST. LOAD:48917 VA RECEPTACLE:29880 VA 19940 VA TOTAL CONN. LOAD:58125 VA LIGHTING:576 VA 720 VA CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:174 A 149 A 166 A Total Load:20598 VA 17849 VA 19678 VA 125 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 126 123 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 124 121 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 122 119 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 120 117 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 118 115 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 116 113 -- SPARE 20 1 0 0 1 20 SPARE -- 114 111 -- SPARE 20 1 0 0 1 20 SPARE -- 112 109 -- SPARE 20 1 0 0 1 20 SPARE -- 110 107 -- SPARE 20 1 0 0 1 20 SPARE -- 108 105 -- SPARE 20 1 0 0 1 20 SPARE -- 106 103 -- SPARE 20 1 0 0 1 20 SPARE -- 104 101 -- SPARE 20 1 0 0 1 20 SPARE -- 102 99 -- SPARE 20 1 0 0 1 20 SPARE -- 100 97 -- SPARE 20 1 0 0 1 20 SPARE -- 98 95 -- SPARE 20 1 0 0 1 20 SPARE -- 96 93 -- SPARE 20 1 0 0 1 20 SPARE -- 94 91 -- SPARE 20 1 0 0 1 20 SPARE -- 92 89 -- SPARE 20 1 0 0 1 20 SPARE -- 90 87 -- SPARE 20 1 0 0 1 20 SPARE -- 88 85 -- SPARE 20 1 0 0 1 20 SPARE -- 86 83 L LTG - MONUMENT SIGN 20 1 100 0 1 20 SPARE -- 84 81 R RECPT - ELEV MECH 118 20 1 180 0 1 20 SPARE -- 82 79 E VAV CONTROLS TRANSFORMER 20 1 500 600 1 20 ELEVATOR CAB E 80 77 L L MEN 105 20 1 476 500 1 20 FIRE SMOKE DAMPER E 78 75 L; R RECPTS - ELEVATOR PIT 20 1 180 348 1 20 EF-13 M 76 73 E CONTROL PANEL - GYM DIVIDER, HOOP ADJ 20 1 400 1176 1 20 SP-1 M 74 71 E DOOR HOLD - EXIT STAIR S10 20 1 200 200 1 20 DOOR HOLD - EMPLOYEE ENTRANCE E 72 69 R RECPTS - GYM NORTH 20 1 720 1260 1 20 RECPTS - GYM STORAGE, EXTERIOR R 70 67 E RECPT - GYM SCOREBOARD 20 1 500 1540 1 20 RECPTS - GYM SOUTH E; R 68 65 E GYM SCOREBOARD 20 1 500 180 1 20 RECPT - GYM SCOREBOARD R 66 63 M RECPT - MP GROUP EX FAN 20 1 500 1080 1 20 RECPTS - STRENGTH 123 R 64 61 R RECPTS - MP GROUP EX 20 1 900 500 1 20 RECPT - MP GROUP EX FAN M 62 59 R DED RECPT - GAMES 20 1 180 1080 1 20 RECPTS - MP GROUP EX R 60 57 R DED RECPT - GAMES 20 1 180 180 1 20 DED RECPT - GAMES R 58 55 R DED RECPT - GAMES 20 1 180 180 1 20 DED RECPT - GAMES R 56 53 R DED RECPT - GAMES 20 1 180 180 1 20 DED RECPT - GAMES R 54 51 R DED RECPT - GAMES 20 1 180 1000 1 20 PROJECTOR - JR GOLF E 52 49 E EWC - STRENGTH 20 1 500 360 1 20 RECPTS - JR GOLF R 50 47 R AC RECPT - KID WATCH 288 20 1 180 1000 1 20 PROJECTOR - GOLF SIMULATOR E 48 45 R RECPTS - MECH 116, STRENGTH 20 1 1080 540 1 20 RECPTS - JR GOLF R 46 43 E SUMP PUMP CONTROL PANEL 20 1 200 360 1 20 RECPTS - JR GOLF R 44 41 M MOTORIZED SCREEN - CLASSROOM 114 20 1 500 1080 1 20 RECPTS - STRENGTH 123 R 42 39 R RECPTS - KITCHEN 112, CLASSROOM 20 1 1440 900 1 20 RECPTS - RECV/STOR, MECH R 40 37 -- ---- -- 2500 360 1 20 AC RECPT - CLASSROOM 114 R 38 35 E RANGE - KITCHEN 112 30 2 2500 1000 1 20 PROJECTOR - CLASSROOM 114 E 36 33 M DISPOSAL - KITCHEN 112 20 1 1176 180 1 20 AC RECPT - KITCHEN 112 R 34 31 E REFRIGERATOR - KITCHEN 112 20 1 1000 180 1 20 MICROWAVE - KITCHEN 112 R 32 29 M MOTORIZED DOOR OPENER - VESTIBULE 101 20 1 2352 180 1 20 AC RECPT - KITCHEN 112 R 30 27 R RECPTS - STRENGTH 20 1 900 180 1 20 AC RECPT - KITCHEN 112 R 28 25 R RECPTS - LOUNGE, ELEC 109 20 1 900 2352 1 20 MOTORIZED DOOR OPENER - VESTIBULE 101 M 26 23 R RECPTS - LOUNGE DESK 20 1 1080 500 1 20 EWC - STRENGTH E 24 21 R RECPTS - STAFF ROOM 107 20 1 900 720 1 20 RECPTS - LOUNGE DESK R 22 19 R RECPTS - STAFF ROOM 107 20 1 1080 900 1 20 RECPTS - P&R DIRECTOR R 20 17 M TF-2 15 1 350 900 1 20 RECPTS - STAFF ROOM 107 R 18 15 E FIREPLACE IGNITION SWITCH 20 1 500 720 1 20 RECPTS - RESTROOMS 104, 105 R 16 13 E EWC - LOUNGE 20 1 500 180 1 20 FLOOR BOX - LOUNGE R 14 11 M MOTORIZED SCREEN - COMMUNITY ROOM 20 1 500 1620 1 20 RECPTS - LOUNGE R 12 9 R FLOOR BOXES - COMMUNITY ROOM 20 1 360 1000 1 20 PROJECTOR - COMMUNITY ROOM E 10 7 R FLOOR BOXES - COMMUNITY ROOM 20 1 360 360 1 20 FLOOR BOXES - COMMUNITY ROOM R 8 5 R RECPTS - COMMUNITY ROOM 20 1 1080 1080 1 20 RECPTS - COMMUNITY ROOM R 6 3 E CUH-3, UH-4 15 1 365 1080 1 20 RECPTS - COMMUNITY ROOM, EXTERIO R 4 1 E CUH-4, CUH-5, UH-5 15 1 950 1080 1 20 RECPTS - COMMUNITY ROOM R 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:400 A MOUNTING:SURFACE WIRES:4 MAINS RATING:400 A SUPPLY FROM:T1B PHASES:3 MAINS TYPE:MCB LOCATION:ELEC 109 VOLTS:120/208 Wye A.I.C. RATING:14,000 AIC PANEL: LP1B AE DESIGN Integrated Lighting and Electrical Solutions 1900 Wazee Street #350 Denver, CO 80202 303.296.3034 aedesign-inc.com SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET Project #: 3256.00 10-31-2016 10 / 3 1 / 2 0 1 6 1 1 : 2 0 : 1 9 A M C: \ U s e r s \ t k i e l t y \ D o c u m e n t s \ 3 2 5 6 . 0 0 - E V C C E l e c C e n t ra l _ t k i e l t y @ a e d e s i g n - i n c . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 ELECTRICAL SCHEDULES E505 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O NOTES: KITCH EQUIP:TOTAL EST. DEMAND:39 A EQUIPMENT:9496 VA 9496 VA TOTAL CONN.:38 A MOTOR:1928 VA 2378 VA TOTAL EST. LOAD:14034 VA RECEPTACLE:2160 VA 2160 VA TOTAL CONN. LOAD:13584 VA LIGHTING: CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:56 A 49 A 17 A Total Load:6164 VA 5340 VA 2080 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 30 27 -- SPARE 20 1 0 0 -- -- BUSSED SPACE -- 28 25 -- SPARE 20 1 0 0 1 20 SPARE -- 26 23 -- KH-1 SHUNT TRIP SPACE -- --0 0 1 20 SPARE -- 24 21 M KH-1 20 1 1800 0 1 20 SPARE -- 22 19 M EF-16 15 1 128 0 1 20 SPARE -- 20 17 R AC RECPT - COMMUNITY KITCHEN 20 1 540 0 1 20 SPARE -- 18 15 R AC RECPT - COMMUNITY KITCHEN 20 1 180 180 1 20 AC RECPT - COMMUNITY KITCHEN R 16 13 E REFRIGERATOR - COMMUNITY KITCHEN 20 1 1000 360 1 20 AC RECPT - COMMUNITY KITCHEN R 14 11 R AC RECPT - COMMUNITY KITCHEN 20 1 180 1000 1 20 REFRIGERATOR - COMMUNITY KITCHEN E 12 9 -- ---- -- 1000 1000 -- -- ---- 10 7 E OVEN - COMMUNITY KITCHEN 30 2 1000 1000 2 30 OVEN - COMMUNITY KITCHEN E 8 5 R AC RECPT - COMMUNITY KITCHEN 20 1 180 180 1 20 AC RECPT - COMMUNITY KITCHEN R 6 3 R AC RECPT - COMMUNITY KITCHEN 20 1 180 1000 1 20 MICROWAVE - COMMUNITY KITCHEN E 4 1 R AC RECPT - COMMUNITY KITCHEN 20 1 180 2496 1 30 DISHWASHER - COMMUNITY KITCHEN E 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:100 A MOUNTING:SURFACE WIRES:4 MAINS RATING:100 A SUPPLY FROM:T1K PHASES:3 MAINS TYPE:MCB LOCATION:ALT KITCHEN 142 VOLTS:120/208 Wye A.I.C. RATING:22,000 AIC PANEL: LK1B NOTES: KITCH EQUIP:TOTAL EST. DEMAND:61 A EQUIPMENT:17500 VA 17500 VA TOTAL CONN.:61 A MOTOR:TOTAL EST. LOAD:22000 VA RECEPTACLE:4500 VA 4500 VA TOTAL CONN. LOAD:22000 VA LIGHTING: CCT TYPE:LOAD DEMAND LOAD PANEL TOTALS LEGEND Total Amps:76 A 54 A 54 A Total Load:9120 VA 6440 VA 6440 VA 41 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 42 39 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 40 37 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 38 35 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 36 33 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 34 31 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 32 29 -- BUSSED SPACE -- --0 0 -- -- BUSSED SPACE -- 30 27 -- BUSSED SPACE -- -- 0 0 -- -- BUSSED SPACE -- 28 25 -- SPARE 20 1 0 0 1 20 SPARE -- 26 23 -- SPARE 20 1 0 0 1 20 SPARE -- 24 21 -- SPARE 20 1 0 0 1 20 SPARE -- 22 19 E TWISTLOCK RECPT - LAN IT RACK 30 1 2500 0 1 20 SPARE -- 20 17 E TWISTLOCK RECPT - LAN IT RACK 30 1 2500 2500 1 30 TWISTLOCK RECPT - LAN IT RACK E 18 15 E TWISTLOCK RECPT - LAN IT RACK 30 1 2500 2500 1 30 TWISTLOCK RECPT - LAN IT RACK E 16 13 E TWISTLOCK RECPT - LAN IT RACK 30 1 2500 2500 1 30 TWISTLOCK RECPT - LAN IT RACK E 14 11 R QUAD RECPT - LAN IT RACK 20 1 360 360 1 20 QUAD RECPT - LAN IT RACK R 12 9 R QUAD RECPT - LAN IT RACK 20 1 360 360 1 20 QUAD RECPT - LAN IT RACK R 10 7 R QUAD RECPT - LAN 20 1 360 360 1 20 QUAD RECPT - LAN IT RACK R 8 5 R QUAD RECPT - LAN 20 1 360 360 1 20 QUAD RECPT - LAN R 6 3 R QUAD RECPT - LAN 20 1 360 360 1 20 QUAD RECPT - LAN R 4 1 R RECPTS - IT ROOM 20 1 540 360 1 20 QUAD RECPT - LAN R 2 CKT CCT TYPE LOAD DESCRIPTION TRIP POLES A B C POLES TRIP LOAD DESCRIPTION CCT TYPE CKT Notes: ENCLOSURE:TYPE 1 MCB RATING:100 A MOUNTING:SURFACE WIRES:4 MAINS RATING:100 A SUPPLY FROM:TBT PHASES:3 MAINS TYPE:MCB LOCATION:LAN 276 VOLTS:120/208 Wye A.I.C. RATING:10,000 AIC PANEL: LT2B