HomeMy WebLinkAboutPLANS 660 Community dr Mechanical Plumbing 2016-10-31GENERAL LEGEND HVAC LEGEND HVAC LEGEND PLUMBING LEGEND XXX X P/T SECTION/DETAIL IS DRAWN XXX = SHEET NUMBER WHERE X = SECTION/DETAIL NUMBER PRESSURE GAUGE WITH COCK THERMOMETER PRESSURE RELIEF VALVE TEE OFF TOP OF PIPE TEE OFF BOTTOM OF PIPE PRESSURE/TEMPERATURE TEST PLUG PIPE ELBOW UP PIPE ELBOW DOWN AIRFLOW - RETURN/EXHAUST TA RA EA OA SA RETURN AIR EXHAUST AIR TRANSFER AIR AIRFLOW - SUPPLY OUTSIDE AIR SUPPLY AIR MVD RETURN OR EXHAUST REGISTER OR GRILLE STANDARD RADIUS ELBOW NEW RECTANGULAR DUCTWORK - WIDTH x DEPTH EXISTING RECTANGULAR DUCTWORK TO REMAIN EXISTING RECTANGULAR DUCTWORK TO BE REMOVED FLEXIBLE DUCTWORK SLOT DIFFUSER BACKDRAFT DAMPER 10x8 45° TAKEOFF DUCT ELBOW WITH TURNING VANES RETURN/EXHAUST DUCT UP/RETURN/EXHAUST DUCT DOWN SUPPLY DUCT UP/SUPPLY DUCT DOWN MANUAL VOLUME DAMPER CONICAL SPIN-IN FITTING WITH MANUAL VOLUME DAMPER CONICAL SPIN-IN FITTING WITHOUT MANUAL VOLUME DAMPER OFFSET DUCT UP / DOWN IN DIRECTION OF ARROW SQUARE TO ROUND TRANSITION DN UP DI DIGITAL INPUT BV CV AUTOMATIC AIR VENT MANUAL AIR VENT BUTTERFLY VALVE GLOBE VALVE BALL VALVE BALANCING VALVE FLEXIBLE PIPE CONNECTION CONCENTRIC PIPE REDUCER ECCENTRIC PIPE REDUCER STRAINER WITH BLOWDOWN VALVE CHECK VALVE PIPE UNION STRAINER AD/AP (E) N.O. N.C. POINT OF CONNECTION - NEW TO EXISTING DIRECTION OF FLOW IN PIPE PITCH PIPE DOWN IN DIRECTION OF ARROW FLOW METER FITTING ACCESS DOOR/ACCESS PANEL EXISTING (DEMOLITION OR REMOVED) CONTROL WIRING EXISTING NORMALLY OPEN NORMALLY CLOSED F.P.C. A.F.F. N.I.C. K.E.C. T.C.C. M.C. E.C. ABBV. G.C. SYMBOL ELECTRICAL CONTRACTOR ABOVE FINISHED FLOOR MECHANICAL CONTRACTOR TEMPERATURE CONTROL CONTRACTOR FIRE PROTECTION CONTRACTOR KITCHEN EQUIPMENT CONTRACTOR NOT IN CONTRACT GENERAL CONTRACTOR FSD FD TCV MCD COMBINATION MOTORIZED FIRE/SMOKE DAMPER TEMPERATURE SENSOR ANALOG FLOW MEASURING DEVICE VARIABLE FREQUENCY DRIVEVFD AO AI DO MS FMD ANALOG OUTPUT ANALOG INPUT DIGITAL OUTPUT MOTOR STARTER P THERMOSTAT PRESSURE SENSOR FIRE DAMPER COMPOUND PRESSURE GAUGE MOTORIZED CONTROL DAMPER (2 OR 3-WAY) TEMPERATURE CONTROL VALVE P DESCRIPTION HWR HWS ABBV. HEATING WATER SUPPLY HEATING WATER RETURNHWR SYMBOL HWS DESCRIPTION B DSCU P FCU RF BBR UH CUH BOILER PUMP DUCTLESS SPLIT CONDENSING UNIT FAN COIL UNIT CABINET UNIT HEATER UNIT HEATER RETURN FAN BASEBOARD RADIATION SYMBOLABBV. EF SF EXHAUST FAN SUPPLY FAN DESCRIPTION AS ET LVR PDU AIR SEPARATOR EXPANSION TANK LOUVER POOL DEHUMIDIFICATION UNIT ROOFTOP UNITRTU MA MAKE-UP AIR SR ER EXHAUST REGISTER SUPPLY REGISTER SOUND ATTENUATOR SMOKE DETECTOR HUMIDITY SENSOR GAUGE PIPE CAP TG TRANSFER GRILLE DIFFERENTIAL PRESSURE TRANSMITTER STATIC PRESSURE TRANSMITTERSPT DPT ROUND DUCT UP / DOWN DSIU DUCTLESS SPLIT INDOOR UNIT CEILING DIFFUSER (FOUR WAY THROW PATTERN) CEILING DIFFUSER WITH FLOW PATTERN INDICATION (TWO WAY)EQUALS CEILING DIFFUSER WITH FLOW PATTERN INDICATION (TWO WAY)EQUALS CEILING DIFFUSER WITH FLOW PATTERN INDICATION (ONE WAY)EQUALS CEILING DIFFUSER WITH FLOW PATTERN INDICATION (THREE WAY)EQUALS A.F.G.ABOVE FINISHED GRADE B.F.F.BELOW FINISHED FLOOR B.F.G.BELOW FINISHED GRADE MAU MAKE-UP AIR UNIT CD CD CD CD CD SD RG/EG RETURN GRILLE WITH SOUND BOOT VAV TERMINAL UNITVAV 3-WAY MANUAL VALVE RL RS REFRIGERANT SUCTION REFRIGERANT LIQUIDRL RS CARBON DIOXIDE SENSORCO2 SLOT DIFFUSERSD SG SUPPLY GRILLE RG RETURN GRILLE EG EXHAUST GRILLE OS OCCUPANCY SENSOR S M H T T B WALL SWITCH$ WALL SWITCH WITH PILOT LIGHT$PL (E)10x8 10x8 TMV GDU DF SH EWC THERMOSTATIC MIXING VALVE GARBAGE DISPOSAL UNIT ELECTRIC WATER COOLER SHOWER DRINKING FOUNTAIN MSB S L U WC FD RD/OD FS VTR WCO GCO FCO LS D LS D LAVATORY URINAL MOP SERVICE BASIN SINK WATER CLOSET ROOF DRAIN/OVERFLOW DRAIN FLOOR DRAIN FLOOR SINK VENT THRU ROOF WALL CLEANOUT GRADE CLEANOUT FLOOR CLEANOUT LAWN SPRINKLER DRAIN PIPING W RDL SD V W HWC HW CW ABBV. SYMBOL ROOF DRAIN ABOVE FLOOR OR GRADE STORM DRAIN BELOW FLOOR OR GRADE SANITARY WASTE ABOVE FLOOR SANITARY WASTE BELOW FLOOR DOMESTIC HOT WATER CIRCULATING DOMESTIC HOT WATER SANITARY VENT DOMESTIC COLD WATER DESCRIPTION PP PLUMBING CIRC. PUMP SP SUMP PUMP SE SEWAGE EJECTOR PET PLUMBING EXPANSION TANK SHOCK ABSORBER (ELEVATION) PIPE GUIDE QUICK OPENING VALVE FLOW SWITCH HOSE BIBB/WALL HYDRANT PIPE ANCHOR SHOCK ABSORBER (PLAN) PRESSURE REDUCING VALVE HOSE END DRAIN VALVE PLUG VALVE GAS COCK SPLASH BLOCK SPLASH BLOCK WITH DOWNSPOUT NOZZLE OR EEW EMERGENCY EYE WASH ES EMERGENCY SHOWER TP/TS TRAP PRIMER/TRAP SEAL WHA WATER HAMMER ARRESTER SI SOLIDS INTERCEPTOR RPBP REDUCED PRESSURE BACKFLOW PREVENTER DCBP DOUBLE CHECK BACKFLOW PREVENTER GW GREASE WASTEGW DFS DRY FIRE SPRINKLER F FIRE LINE FS FIRE SPRINKLER FSP FIRE STANDPIPE DFS F FS ODL OVERFLOW DRAIN LEADER ABOVE FLOOR OR GRADE RDL ODL OR AD AREA DRAIN HB/WH OR G NATURAL GASG F SA CA COMBUSTION AIR NEW RECTANGULAR INSULATED DUCTWORK NEW ROUND DUCTWORK - DIAMETER10"ø PWR PWR POOL HEATING WATER SUPPLY POOL HEATING WATER RETURN PWSPWS KH KITCHEN HOOD The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 6 : 5 2 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MECHANICAL COVER SHEET - LEGEND, GENERAL NOTES & DRAWING INDEX MP000 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SHEET INDEX SHEET NUMBER MECHANICAL, PLUMBING & FIRE PROTECTION SHEET TITLES SHEET SCALE MP000 MECHANICAL COVER SHEET - LEGEND, GENERAL NOTES & DRAWING INDEX NONE MD104 MAIN LEVEL HVAC DEMOLITION PLAN - SOUTH 1/8"=1'-0" MD105 ROOF HVAC DEMOLITION PLAN 1/8"=1'-0" MD204 MAIN LEVEL HVAC PIPING DEMOLITION PLAN - SOUTH 1/8"=1'-0" M102 LOWER LEVEL HVAC PLAN 1/16"=1'-0" M103 MAIN LEVEL HVAC PLAN - NORTH 1/8"=1'-0" M104 MAIN LEVEL HVAC PLAN - SOUTH 1/8"=1'-0" M105 ROOF HVAC PLAN 1/8"=1'-0" M202 LOWER LEVEL HVAC PIPING PLAN 1/8"=1'-0" M203 MAIN LEVEL HVAC PIPING PLAN - NORTH 1/8"=1'-0" M204 MAIN LEVEL HVAC PIPING PLAN - SOUTH 1/8"=1'-0" M301 HVAC SECTIONS 1/4"=1'-0" M302 HVAC SECTIONS 1/4"=1'-0" M401 ENLARGED MECHANICAL ROOM HVAC PLAN 1/4"=1'-0" M501 HVAC DETAILS NONE M502 HVAC DETAILS NONE M601 HVAC CONTROL DRAWINGS NONE M602 HVAC CONTROL DRAWINGS NONE M603 HVAC CONTROL DRAWINGS & HEATING WATER PIPING SCHEMATIC NONE M701 HVAC SCHEDULES NONE M702 HVAC SCHEDULES NONE M703 HVAC SCHEDULES & OUTSIDE AIR CALCULATIONS NONE M704 HVAC OUTSIDE AIR CALCULATIONS NONE FP101 LOWER LEVEL FIRE PROTECTION PLAN 1/16"=1'-0" FP102 MAIN LEVEL FIRE PROTECTION PLAN 1/16"=1'-0" PD101 PLUMBING DEMOLITION PLANS AS INDICATED P100 PLUMBING SITE PLAN 1"=30'-0" P102 LOWER LEVEL PLUMBING PLAN 1/8"=1'-0" P103 MAIN LEVEL PLUMBING PLAN - NORTH 1/8"=1'-0" P104 MAIN LEVEL PLUMBING PLAN - SOUTH 1/8"=1'-0" P105 ROOF PLUMBING PLAN 1/16"=1'-0" P401 ENLARGED PLUMBING PLANS 1/4"=1'-0" P402 ENLARGED PLUMBING PLANS 1/4"=1'-0" P501 PLUMBING DETAILS NONE P601 PLUMBING ISOMETRICS NONE P602 PLUMBING ISOMETRICS NONE P701 PLUMBING SCHEDULES NONE MECHANICAL DEMOLITION GENERAL NOTES 1. COORDINATE DEMOLITION REQUIREMENTS WITH GENERAL CONTRACTOR. 2. COORDINATE EXTENT OF DEMOLITION WITH NEW CONSTRUCTION AS SHOWN IN THESE DOCUMENTS. 3. EXISTING MECHANICAL WORK IS SHOWN LIGHT. 4. ALL MECHANICAL ITEMS INDICATED TO BE DEMOLISHED SHALL BE INSPECTED FOR SALVAGE BY OWNER. ALL NON-SALVAGEABLE ITEMS SHALL THEN BE IMMEDIATELY REMOVED FROM SITE BY MECHANICAL CONTRACTOR. 5. ALL UNUSED TEMPERATURE CONTROL WIRING, WIRE MOLD, PNEUMATIC TUBING, AND CONTROL COMPONENTS SHALL BE REMOVED. 6. ALL UNUSED HANGERS AND SUPPORTS SHALL BE REMOVED. 7. REMOVAL OR INSTALLATION OF CONTROLS, PIPES, DUCTS, AND EQUIPMENT MAY REQUIRE REMOVAL OF EXISTING WALLS AND CEILINGS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND PAINTING THESE WALLS AND/OR CEILINGS to MATCH EXISTING WHERE NOT REPLACED UNDER ARCHITECTURAL DOCUMENTS. GENERAL CONTRACTOR SHALL REVIEW MECHANICAL DRAWINGS TO IDENTIFY THESE LOCATIONS PRIOR TO BID PRICING. 8. GENERAL CONTRACTOR SHALL PATCH AND PAINT WALL TO MATCH EXISTING AT DEMOLISHED CONTROLS. 9. GENERAL CONTRACTOR SHALL PATCH AND SEAL UNUSED ROOF PENETRATIONS AT DEMOLISHED MECHANICAL TO MATCH EXISTING CONDITIONS. 10. GENERAL CONTRACTOR SHALL PATCH THE CEILING, ROOF AND WALLS TO MATCH EXISTING AT DEMOLISHED HANGERS AND SUPPORTS. 11. GENERAL CONTRACTOR SHALL MAKE REPAIRS TO ALL EXISTING BUILDING COMPONENTS THAT HAVE BEEN AFFECTED BY DEMOLITION OF MECHANICAL SYSTEMS. MECHANICAL GENERAL NOTES 1. MECHANICAL CONTRACTOR SHALL INSPECT SITE TO BECOME FAMILIAR WITH SCOPE OF WORK. THESE DOCUMENTS DO NOT REFLECT AS-BUILT CONDITIONS. ANY DISCREPANCIES BETW EEN THESE DOCUMENTS AND ACTUAL CONDITIONS SHALL BE REPORTED TO ARCHITECT/ENGINEER FOR RESOLUTION PRIOR TO BID PRICING. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. 2. MECHANICAL CONTRACTOR SHALL COORDINATE LOCATION OF ALL ABOVE CEILING EQUIPMENT, DUCTWORK AND CEILING MOUNTED AIR DEVICES WITH EXISTING ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND MECHANICAL CONDITIONS. APPROXIMATE LOCATIONS OF NEW WORK ARE SHOWN AND SHOULD BE FOLLOWED AS CLOSELY AS EXISTING CONDITIONS WILL ALLOW. 3. MECHANICAL WORK SHALL COMPLY WITH ALL APPLICABLE CODES. VERIFY ALL REQUIREMENTS PRIOR TO SUBMITTING BID OR COMMENCING WORK. 4. MECHANICAL SYSTEM SHOWN SHALL BE ROUTED AS HIGH AS POSSIBLE. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING REQUIREMENTS WITH ALL TRADES PRIOR TO CONSTRUCTION. 5. WHERE CEILING SPACE IS TO BE USED AS RETURN AIR PLENUM, COMPLY WITH ALL APPLICABLE CODES. ALL MATERIALS WITHIN CEILING PLENUM SHALL HAVE FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 50. 6. WHERE CEILING SPACE IS TO BE USED AS RETURN AIR PLENUM, GENERAL AND MECHANICAL CONTRACTORS SHALL VERIFY THAT RETURN AIR PATH BACK TO UNIT IS OPEN WITH VELOCITY THROUGH ALL OPENINGS OF 400 FPM OR LESS. 7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING AIR DEVICES AND ACCESS PANELS. OBTAIN CLARIFICATION FROM ARCHITECT, IF EXACT LOCATIONS ARE NOT SHOWN. 8. REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING DETAILS SPECIFIC TO THIS PROJECT. 9. MECHANICAL CONTRACTOR SHALL COORDINATE THERMOSTAT, SENSOR, AND SWITCH LOCATIONS WITH ARCHITECT/ENGINEER PRIOR TO INSTALLATION. ALL THERMOSTATS, SENSORS, AND SWITCHES SHALL BE LOCATED 48" A.F.F. UNLESS INDICATED OTHERWISE. 10. COORDINATE THERMOSTAT, SENSOR, AND SWITCH LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT/ENGINEER PRIOR TO INSTALLATION. WHERE POSSIBLE MATCH LOCATION OF PREVIOUS CONTROLLERS. PROVIDE WIRE MOLD TO CONCEAL EXPOSED CONTROL WIRING. COLOR TO BE SELECTED BY ARCHITECT. 11. BALANCE AIR AND WATER SYSTEMS TO QUANTITIES SHOW N AND SUBMIT BALANCE REPORT(S) TO ARCHITECT/ENGINEER FOR REVIEW. 12. PORTIONS OF THIS BUILDING WILL BE OCCUPIED DURING THIS CONSTRUCTION PROJECT. MECHANICAL CONTRACTOR SHALL COORDINATE SCHEDULING OF THEIR WORK WITH GENERAL CONTRACTOR. CLEAN UP AT END OF EACH DAY. 13. ACCESS DOORS SHALL BE INSTALLED IN ORDER TO PROVIDE ACCESS TO MECHANICAL SYSTEMS LOCATED ABOVE INACCESSIBLE CEILINGS, WHETHER OR NOT SHOWN ON DRAW INGS. ACCESS DOORS SHALL BE FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. PROVIDE 12"x12" ACCESS DOORS FOR HAND ACCESS AND 24"x24" ACCESS DOORS FOR HEAD AND SHOULDER ACCESS. MECHANICAL HVAC NOTES 1. DUCTWORK DIMENSIONS LISTED ON DRAWINGS ARE CLEAR, INSIDE DIMENSIONS. 2. FLEXIBLE DUCTWORK SHALL BE INSULATED AND SHALL BE SAME SIZE AS NECK OF AIR DEVICE. FLEXIBLE DUCTWORK SHALL NOT EXCEED 8'-0" IN LENGTH. PROVIDE WRAPPED RIGID ROUND DUCTWORK FOR TAKEOFFS IN EXCESS OF 8'-0". 3. UNLESS SHOWN OTHERWISE, INLET DUCTWORK VARIABLE AIR VOLUME TERMINALS SHALL BE FULL SIZE OF UNIT CONNECTION. 4. PROVIDE DUCT TRANSITIONS FROM EQUIPMENT CONNECTIONS TO DUCT SIZES, AS SHOWN. 5. PROVIDE FLEXIBLE CONNECTION FOR INTAKE AND DISCHARGE OF ANY MECHANICAL EQUIPMENT HAVING ROTATING PARTS. FLEXIBLE CONNECTION SHALL COMPLY WITH ALL APPLICABLE CODES. 6. ALL DUCTWORK SHALL BE MINIMUM 26 GAUGE SHEETMETAL, OR AS REQUIRED BY ALL APPLICABLE CODES. ALL DUCTWORK CROSSING RATED CORRIDORS SHALL BE MINIMUM 24 GAUGE SHEETMETAL. MEET OR EXCEED S.M.A.C.N.A. STANDARDS. 7. ALL DUCTWORK SHALL BE SEALED AIRTIGHT WITH DUCT SEALANT (S.M.A.C.N.A. SEAL CLASS "A") ALONG ALL SEAMS AND JOINTS. 8. ALL RECTANGULAR SUPPLY, RETURN AND TRANSFER AIR DUCTWORK SHALL BE SHEETMETAL LINED WITH 1" DUCT LINER UNLESS NOTED OTHERWISE OR SERVING AS PART OF THE POOL DEHUMIDIFICATION SYSTEM. 9. ALL EXHAUST AIR DUCTWORK SHALL BE UNLINED SHEETMETAL, UNLESS NOTED OTHERWISE. 10. ALL DUCTWORK SERVING CHEMICAL STORAGE ROOMS SHALL BE CONSTRUCTED OF SCHEDULE 40 CPVC PIPING. CPVC COATED STEEL DUCTWORK IS NOT ACCEPTABLE. 11. ALL EXPOSED SPIRAL ROUND DUCTWORK SHALL BE SHEETMETAL LINED WITH 1" DUCT LINER UNLESS NOTED OTHERWISE OR SERVING AS PART OF THE POOL DEHUMIDIFICATION SYSTEM.. 12. ALL CONCEALED SPIRAL ROUND DUCTWORK SHALL BE SHEETMETAL WRAPPED WITH 2" DUCT WRAP. 13. ALL UNLINED DUCTWORK THAT IS VISIBLE THROUGH THE AIR DEVICE SHALL BE PAINTED FLAT BLACK. 14. MAINTAIN MINIMUM 10'-0" SEPARATION FROM OUTSIDE AIR INTAKES TO EXHAUST TERMINATIONS AND FLUE OUTLETS. 15. MAINTAIN MINIMUM 15'-0" FROM OUTSIDE AIR INTAKES TO PLUMBING VENTS. 16. MAINTAIN MINIMUM 3'-0" SEPARATION FROM EXHAUST TERMINATIONS TO OPERABLE WINDOWS AND DOORS. 17. COORDINATE LOUVER, WALL CAP AND AIR DEVICE PLACEMENT WITH BRICK OR BLOCK COURSING WHERE APPLICABLE. 18. COORDINATE LOCATION AND ELEVATION OF ALL EXPOSED DUCTWORK WITH ARCHITECT AT JOB SITE. 19. ALL EXPOSED DUCTWORK SHALL BE FREE OF IMPERFECTIONS AND DAMAGE. SEAL EXPOSED DUCTWORK IN NEAT WORKMANSHIP LIKE MANNER SUITABLE FOR PAINTING. 20. GENERAL CONTRACTOR SHALL PAINT ALL EXPOSED DUCTW ORK, FITTINGS, ETC. IN ACCORDANCE WITH ARCHITECTURAL SPECIFICATION. 21. ALL EXPOSED DUCTWORK THAT IS SPECIFIED TO BE PAINTED SHALL BE PROVIDED WITH PAINT-LOCK PRIMER TO PREPARE DUCTWORK FOR FIELD PAINTING. 22. CUT ROOFTOP UNIT DUCT OPENINGS THROUGH ROOF 1/2" LARGER THAN OUTSIDE DIMENSION OF SUPPLY AND RETURN AIR DUCTWORK. SEAL OPENINGS AROUND DUCTWORK. 23. COMPLETELY FILL ALL ROOFTOP UNIT ROOF CURBS WITH UNFACED BATT INSULATION. LAYER INSULATION IN NEAT WORKMANSHIP LIKE MANNER. 24. SPIN-IN FITTINGS SERVING GRILLES AND DIFFUSERS SHALL BE CONICAL WITH MANUAL VOLUME DAMPERS, UNLESS AIR DEVICE IS PROVIDED WITH OPPOSED BLADE DAMPER. 25. SPIN-IN FITTINGS SERVING VARIABLE AIR VOLUME TERMINAL UNITS SHALL BE CONICAL WITHOUT MANUAL VOLUME DAMPERS. 26. RECTANGULAR BRANCH DUCTWORK TAKEOFFS SHALL HAVE 45° TAKEOFFS AND ROUND DUCTWORK TAKEOFFS SHALL BE CONICAL. 27. ALL ELBOWS, BOTH HORIZONTAL AND VERTICAL, SHALL BE LONG RADIUS ELBOWS WHEREVER POSSIBLE, OR SHALL HAVE TURNING VANES WHERE SHOWN. 28. 12"x12" ACCESS DOORS SHALL BE PROVIDED FOR ALL MANUAL VOLUME DAMPERS LOCATED ABOVE GYPSUM BOARD CEILINGS. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 29. 24"x24" ACCESS DOORS SHALL BE PROVIDED FOR ALL VARIABLE AIR VOLUME TERMINAL UNITS LOCATED ABOVE GYPSUM BOARD CEILINGS. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 30. ALL JOB SITE DUCTWORK PRIOR TO INSTALLATION SHALL BE COVERED AND PROTECTED FROM DIRT, DUST, AND DAMAGE PER SMACNA STANDARDS. 31. ALL NEW AND REPLACEMENT ROOF MOUNTED EQUIPMENT SHALL BE LOCATED AT LEAST 10'-0" FROM EDGE OF ROOF. GENERAL AND MECHANICAL CONTRACTOR SHALL VERIFY AND CONFIRM ACTUAL INSTALLED LOCATIONS OF ALL NEW AND REPLACEMENT ROOF MOUNTED EQUIPMENT. IF THIS EQUIPMENT IS INSTALLED WITHIN 10'-0" OF ROOF EDGE, GENERAL CONTRACTOR SHALL INSTALL O.S.H.A. APPROVED GUARD RAIL. 34. FLUES FOR BOILERS, WATER HEATERS, AND POOL HEATERS SHALL BE ENGINEERED BY FLUE MANUFACTURER, BASED ON ACTUAL EQUIPMENT, AND SHALL BE SUBMITTED TO ENGINEER FOR APPROVAL. 35. DIVISION 26 SHALL PROVIDE 120 VOLT, 20 AMP CIRCUIT FOR DDC SYSTEM LOCATED IN ROOM HOUSING DDC COMPUTER. DIVISION 26 SHALL PROVIDE MULTIPLE 20 AMP CIRCUITS IN CEILING SPACE TO SERVE TERMINAL UNITS' CONTROL TRANSFORMERS. EXACT CIRCUIT LOCATIONS SHALL BE COORDINATED WITH TEMPERATURE CONTROLS CONTRACTOR. DIVISION 26 SHALL PROVIDE ONE PHONE CONNECTION LOCATED IN ROOM HOUSING DDC COMPUTER. COORDINATE DDC SYSTEM MOUNTING LOCATION WITH OWNER. 36. IN EVENT THAT VARIABLE FREQUENCY DRIVE IS ADDED TO EXISTING PIECE OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING MAG STARTER HAS BEEN REMOVED. MECHANICAL CONTRACTOR SHALL ALSO VERIFY THAT MOTOR IS COMPATIBLE FOR OPERATION WITH VARIABLE FREQUENCY DRIVE. IF THERE IS CONFLICT WITH MOTOR, REPORT MOTOR DEFICIENCY TO GENERAL CONTRACTOR IMMEDIATELY. 37. DRYER EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL NOT LESS THAN 0.0195 INCHES. INSIDE OF DRYER DUCT SHALL BE SMOOTH WITH NO MECHANICAL FASTENERS PENETRATING DUCT. POP RIVETS ARE ACCEPTABLE, VERTICAL RISERS SHALL HAVE ACCESSIBLE CLEANOUT. COMPLY WITH MANUFACTURER'S INSTALLATION REQUIREMENTS AND LOCAL CODES. PLUMBING DEMOLITION GENERAL NOTES 1. COORDINATE DEMOLITION REQUIREMENTS WITH THE GENERAL CONTRACTOR. 2. COORDINATE EXTENT OF DEMOLITION WITH THE NEW CONSTRUCTION AS SHOWN IN THESE DOCUMENTS. 3. EXISTING PLUMBING PIPING, EQUIPMENT ETC IS SHOWN LIGHT. 4. ALL PLUMBING ITEMS INDICATED TO BE DEMOLISHED SHALL BE INSPECTED FOR SALVAGE BY THE OWNER. ALL NON-SALVAGEABLE ITEMS SHALL THEN BE IMMEDIATELY REMOVED FROM THE SITE BY THE PLUMBING CONTRACTOR. 5. ALL UNUSED HANGERS AND SUPPORTS SHALL BE REMOVED. 6. THE REMOVAL OR INSTALLATION OF FIXTURES, PIPES AND EQUIPMENT MAY REQUIRE THE REMOVAL OF EXISTING WALLS AND CEILINGS. THE PLUMBING CONTRACTOR AND GENERAL CONTRACTOR SHALL BE COORDINATE AND RESPONSIBLE FOR REPAIRING AND PAINTING THESE WALLS AND/OR CEILINGS SO THEY MATCH THE EXISTING WHERE NOT REPLACED UNDER THE ARCHITECTURAL DOCUMENTS. THE CONTRACTOR SHALL REVIEW THE PLUMBING DRAWINGS TO IDENTIFY THESE LOCATIONS PRIOR TO BID PRICING. 7. THE GENERAL CONTRACTOR SHALL PATCH AND SEAL UNUSED ROOF PENETRATIONS AT DEMOLISHED PLUMBING TO MATCH EXISTING CONDITIONS. 8. THE GENERAL CONTRACTOR SHALL MAKE REPAIRS TO ALL EXISTING BUILDING COMPONENTS THAT HAVE BEEN AFFECTED BY THE DEMOLITION OF PLUMBING SYSTEMS. PLUMBING GENERAL NOTES 1. FIELD VERIFY EXACT LOCATION OF ALL CONNECTION PRIOR TO CONSTRUCTION. 2. ROUGH-IN AND FINAL CONNECT ALL FIXTURES, EQUIPMENT, ETC. 3. CONTRACTOR SHALL INSPECT SITE TO THOROUGHLY FAMILIARIZE HIMSELF WITH THE AREA OF WORK. ANY DISCREPANCES BETWEEN THESE DOCUMENTS AND ACTUAL CONDITIONS SHALL BE REPORTED TO THE ARCHITECT/ENGINEER FOR RESOLUTION PRIOR TO BID PRICING. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. 4. ALL WORK SHALL BE PER LOCAL BUILDING AND HEALTH DEPARTMENT REQUIREMENTS. 5. PROVIDE BALL VALVES ON ALL BRANCH LINES FOR BUILDING ISOLATION WHETHER SHOWN OR NOT. 6. REFERENCE HVAC DRAWINGS FOR EXACT LOCATION OF ALL HVAC EQUIPMENT REQUIRING PLUMBING CONNECTIONS. COORDINATE WITH HVAC CONTRACTOR EXACT PLUMBING CONNECTION REQUIREMENTS PRIOR TO COMMENCING WORK. 7. ALL STORM DRAINAGE PIPING WITHIN THE BOUNDARIES OF THE BUILDING SHALL BE SLOPED AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. 8. ALL VENTS THROUGH THE ROOF (VTR) SHALL BE POSITIONED A MINIMUM OF 15'-0" FROM ANY OUTSIDE AIR INTAKE. 9. REFERENCE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE RATED WALLS. ALL PIPE PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE SEALED IN ACCORDANCE WITH THE BUILDING CODE. 10. OFFSET ALL PIPING AS REQUIRED TO AVOID STRUCTURAL MEMBERS, CANTS, FLASHING, MECHANICAL, OR ELECTRICAL EQUIPMENT. 11. PROVIDE CHROME PLATED SET SCREW TYPE ESCUTCHEONS AT ALL EXPOSED PIPE PENETRATIONS THROUGH WALLS AND CASEWORK. 12. PROVIDE TRAP PRIMERS TO ALL FLOOR DRAINS & FLOOR SINKS WITH ACCESS THAT HAVE THE POSSIBILITY FOR EVAPORATION PROBLEMS AND AS INDICATED IN THE SPECIFICATION. 13. PROTECT ALL EXISTING EQUIPMENT INDICATED AS REMAINING IN PLACE OR BEING RELOCATED. REPLACE DAMAGED EQUIPMENT IMMEDIATELY WITH EXACT DUPLICATE AT NO ADDITIONAL COST TO THE OWNER. 14. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY LOCATING AND PROTECTING ALL EXISTING PIPING AND UTILITIES FOR THE DURATION OF THE WORK. ANY DAMAGE CAUSED TO EXISTING PIPING OR UTILITIES SHALL BE REPAIRED IMMEDIATELY AT NO ADDITIONAL COST TO THE OWNER. 15. PROVIDE PROSET TRAP GUARDS ON ALL FLOOR DRAINS PER CODE WHERE EVAPORATION OR LOSS OF TRAP SEAL WILL OCCUR. 16. VERIFY AND COORDINATE EXACT SIZE, LOCATION, AND ELEVATION OF KITCHEN PLUMBING ROUGH-INS WITH KITCHEN EQUIPMENT CONTRACTOR PRIOR TO CONSTRUCTION. 17. PROVIDE ACCESSIBLE SHUT-OFF VALVES FOR ALL KITCHEN EQUIPMENT REQUIRING WATER SERVICE. 18. ALL EXPOSED PIPING IN THE KITCHEN AREA TO BE A CLEANABLE SURFACE PER LOCAL HEALTH DEPARTMENT. 19. PLUMBING CONTRACTORS SHALL PROVIDE ALL INDIRECT WASTE PIPING AND MAKE FINAL CONNECTIONS TO SINKS, KITCHEN EQUIPMENT, ETC. VERIFY SIZES AND LOCATIONS WITH KITCHEN EQUIPMENT CONTRACTOR'S SHOP DRAWINGS. 20. COMPLY WITH ALL BUILDING AND HEALTH DEPARTMENT REGULATIONS FOR PLUMBING INSTALLATION. VERIFY ALL REQUIREMENTS PRIOR TO SUBMITTING BID OR COMMENCING WORK. 21. PROVIDE FLEXIBLE CONNECTOR WITH QUICK COUPLER CONNECTION TO ALL MOVEABLE GAS APPLIANCES. 22. PROVIDE INSULATION FOR ALL DRAIN PIPING FROM COOLER-FREEZER EVAPORATOR COILS, REFRIGERATED BASES, AND SIMILAR EQUIPMENT. VERIFY REQUIREMENTS WITH KITCHEN EQUIPMENT CONTRACTOR'S SHOP DRAWINGS. 23. FLUSH MOUNT ALL FLOOR SINKS IN KITCHEN AREA FOR FLOOR DRAINAGE USE. 24. ALL GAS PIPING, VALVES, PRV, ETC. SHALL MEET THE REQUIREMENTS OF THE INTERNATIONAL FUEL GAS CODE. MECHANICAL NATATORIUM NOTES 1 ALL SUPPLY, RETURN & EXHAUST AIR DUCTWORK CONNECTED TO POOL DEHUMIDIFICATION UNIT SHALL BE CONSTRUCTED OF ALUMINUM WITHOUT DUCT LINER. PROVIDE ALUMINUM DUCT HANGERS AND SUPPORTS IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. 2. ALL EXTERIOR AND ROOF MOUNTED EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED OF ALUMINUM WITHOUT DUCT LINER AND WITHOUT DUCT WRAP. PROVIDE DUCT SUPPORTS IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. 3. ALL EXTERIOR AND ROOF MOUNTED SUPPLY AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED OF ALUMINUM WITHOUT DUCT LINER AND WRAPPED WITH 2" DUCT WRAP AND ALUMINUM ALL WEATHER JACKETING. TOP OF DUCTWORK SHALL BE SLOPED FOR DRAINAGE. PROVIDE DUCT SUPPORTS IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. 4. CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC WITH 1" FIBERGLASS PIPE INSULATION. PROVIDE FIRE RATED GYPSUM BOARD ENCLOSURE AROUND ANY PIPING LOCATED WITHIN RETURN AIR PLENUMS ABOVE CEILING. PROVIDE 6" CONDENSATE TRAP AND SLOPE PIPING AT 1/8" PER LINEAR FOOT FOR PROPER DRAINAGE. TERMINATE WITH AIR GAP FITTING AT MINIMUM 8" STANDPIPE OR OTHER CODE APPROVED TERMINATION POINT. REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN PIPING. 5. COORDINATE FINAL LOCATIONS OF POOL DEHUMIDIFICATION UNIT'S TEMPERATURE, HUMIDITY, OUTSIDE AIR TEMPERATURE, AND PRESSURE SENSORS WITH MANUFACTURER'S REPRESENTATIVE. MECHANICAL PIPING NOTES 1. HEATING WATER PIPING AND INSULATION: REFER TO SPECIFICATION SECTIONS 23 05 00 AND 23 07 00 RESPECTIVELY FOR PIPING AND INSULATION REQUIREMENTS. 3. GAS PIPING: REFER TO SPECIFICATION SECTIONS 22 05 00 PIPING REQUIREMENTS. 4. REFRIGERANT PIPING AND INSULATION: REFER TO SPECIFICATION SECTIONS 23 05 00 AND 23 07 00 RESPECTIVELY FOR PIPING AND INSULATION REQUIREMENTS. 5. AIR-COOLED CONDENSING UNIT SUPPLIER SHALL SUBMIT A MANUFACTURER APPROVED REFRIGERANT PIPING DIAGRAM SPECIFIC TO THIS PROJECT. CLEARLY IDENTIFY PIPING LENGTHS, DROPS, RISES, SIZES, VALVES, AND SPECIALTIES. 6. INSTALL ALL VALVES ABOVE ACCESSIBLE CEILINGS. PROVIDE 12"x12" ACCESS DOORS FOR ALL VALVES ABOVE GYPSUM CEILINGS. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT DURING COORDINATED SHOP DRAWING REVIEW. 7. ALL PIPING SHOWN IS CONCEALED ABOVE CEILINGS UNLESS INDICATED OTHERWISE. 8. REFER TO TERMINAL UNIT SCHEDULES FOR COIL DESIGNATIONS REQUIRING 3-WAY VALVES. 9. PROVIDE PIPING SLEEVES AT ALL WALL PENETRATIONS. REFER TO SPECIFICATION FOR EXACT REQUIREMENTS. 10. PROVIDE ISOLATION/SHUT-OFF VALVES AT ALL PIPING BRANCHES THAT HAVE TWO OR MORE HYDRONIC DEVICES. 11. IN ADDITION TO COORDINATED SHOP DRAWINGS, PIPING CONTRACTOR SHALL SUBMIT INDIVIDUAL SHOP DRAWING THAT SHOWS ALL MEANS OF HYDRONIC SYSTEM EXPANSION. CONTRACTOR CAN USE EXPANSION LOOPS, ANCHORS AND ROLLERS; OR EXPANSION COMPENSATORS; OR COMBINATION OF BOTH. HYDRONIC EXPANSION LOCATIONS, METHODS, AND EQUIPMENT SHALL BE APPROVED BY ENGINEER PRIOR TO INSTALLATION. 12. ALL RUN OUT PIPING TO HEATING DEVICES SHALL BE MINIMUM 3/4" UNLESS OTHERWISE NOTED. ALL RUN OUT PIPING TO HEATING DEVICES SHALL BE MINIMUM OF 5'-0" IN LENGTH AND SHALL HAVE MINIMUM OF (5) 90° ELBOWS. WHERE THESE REQUIREMENTS ARE NOT POSSIBLE DUE TO SPACE CONSTRAINTS, FLEXIBLE CONNECTIONS AT DEVICE SHALL BE PROVIDED. MAIN LEVEL HVAC DEMOLITION KEYNOTES: REMOVE EXISTING FAN COIL UNIT AND ALL ASSOCIATED CONTROLS, HANGERS, APPURTENANCES AND ALL ASSOCIATED BRANCH PIPING AND SPECIALTIES AS INDICATED. REFER TO SHEET MD204 FOR EXTENT OF PIPING DEMOLITION. 1 REMOVE EXISTING BASEBOARD RADIATION AND ALL ASSOCIATED CONTROLS, SUPPORTS, APPURTENANCES AND ALL ASSOCIATED BRANCH PIPING AND SPECIALTIES AS INDICATED. TYPICAL. REFER TO SHEET MD204 FOR EXTENT OF PIPING DEMOLITION. 2 REMOVE EXISTING LOUVER, AS INDICATED.3 EXISTING DUCTWORK OF SIZE AND TYPE INDICATED TO REMAIN.4 EXISTING AIR DEVICE TO REMAIN, AS INDICATED.5 REMOVE EXISTING AIR DEVICE, AS INDICATED.6 REMOVE EXISTING DUCTWORK TO EXTENT INDICATED.7 (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) EXISTING DUCTWORK OF SIZE AND TYPE INDICATED THROUGH EXTERIOR WALL PENETRATION. REFER TO SHEET M105 FOR CONTINUATION. 8 REMOVE EXISTING UNIT HEATER AND ALL ASSOCIATED CONTROLS, HANGERS AND APPURTENANCES. ALL ASSOCIATED BRANCH PIPING AND SPECIALTIES SHALL REMAIN, AS INDICATED. REFER TO SHEET MD204 FOR PIPING DEMOLITION REQUIREMENTS. 9 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF EG Eh ALL SUPPLY AND RETURN DUCTWORK, AIR DEVICES, CONTROLS, HANGERS, SUPPORTS AND APPURTANCES ASSOCIATED WITH LOCKER ROOM MAKE-UP AIR UNITS AND ENTRY WAY FAN COIL UNIT SHALL BE REMOVED. EXISTING BOILER AND ASSOCIATED POOL HEATING SYSTEMS TO REMAIN. FCU BBR BBR BBR BBR BBR BBR BBR BBR BBRBBRBBR (E)14x12 EA 12x12 EG TYP. (3) 12x12 EG TYP. (5) 6x6 (E)10x10 EA 8x8 8x8 10x10 TO (E)EF (E)14x16 EA (E)44"ø SA (E)38"ø SA (E)30"ø SA (E)22"ø SA (E)18"ø SA (E)24"ø SA (E)20"ø SA (E)26"ø SA (E)32"ø SA (E)SD (E)SD(E)SD TYP. (4) (E)SD (E)SD (E)SD (E)SD (E)SD 1 2 2 2 2 2 2 2 222 2 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 4 4 6 6 7 7 7 7 7 4 7 7 NJ 10x18 LVR30x24 LVR (E)16"ø OA 88 7 4 7 16"ø 4 8"ø EA4 12x12 6x6 4 44x44 SA 4 48x64 LVR 3 8 48(E)68x56 RA 1 M302 30x24 32x12 CA 32x12 7 9UH 7 M301 7 M301 (E)16x14 EA 5 (E)EG The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 6 : 5 7 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC DEMOLITION PLAN - SOUTH MD104 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC DEMOLITION PLAN - SOUTH E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF EG Eh MAU MAU (E)PDU-1 (E)56x68 RA EF 1 1 2 3 4 4 4 NJ 5 (E)8"ø FLUE (E)44x44 SA 7 M301 7 M301 ROOF HVAC DEMOLITION KEYNOTES: REMOVE EXISTING MAKE-UP AIR UNIT AND ALL ASSOCIATED DUCTWORK, AIR DEVICES, CONTROLS AND APPURTENANCES. 1 EXISTING POOL DEHUMIDIFICATION UNIT TO REMAIN, AS INDICATED.2 REMOVE EXISTING ROOF MOUNTED EXHAUST FAN, AS INDICATED.3 EXISTING POOL DEHUMIDIFICATION UNIT EXTERIOR DUCTWORK TO REMAIN, AS INDICATED.4 (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) EXISTING FLUE TO REMAIN, AS INDICATED.5 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/16" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 6 : 5 9 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 ROOF HVAC DEMOLITION PLAN MD105 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/16" = 1'-0" ROOF HVAC DEMOLITION PLAN E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF EG Eh EXISTING BOILER AND ASSOCIATED POOL HEATING AND DOMESTIC HOT WATER SYSTEMS TO REMAIN. FCU BBR BBR BBR BBR BBR BBR BBR BBR BBRBBR BBR (E)2 1/2"(E)2 1/2" HWR HWS (E)3"(E)3" PWS PWR BBR (E)3"(E)3" 3/4" 1/2" (E)2 1/2" 1/2" 1/2" 3/4" 1/2"HWS HWR 1/2"HWR (E)2 1/2" HWS & HWR UP TO (E)PDU-1 ABOVE (E)3" PWS & PWR UP TO (E)PDU ABOVE 3 2 1 1 3 3 3 1 3 1 (E)1/2" 4 44 HWR HWS (E)2 1/2" W. TEAM LOCKERS A106 EXIST POOL DECK A109 EXIST LAUNDRY A111EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST CHEM A115 EXIST NATATORIUM A110 M. TEAM LOCKER A107 STORAGE A105 PWSPWR (E)1/2"(E)1/2" (E)3/4"7 UH HWR HWS MAIN LEVEL HVAC PIPING DEMOLITION KEYNOTES: EXISTING PIPING OF SIZE AND TYPE INDICATED SHALL REMAIN.1 REMOVE EXISTING FAN COIL UNIT AND BRANCH PIPING, AND PROVIDE CAP AT PIPE MAINS, AS INDICATED.2 3 REMOVE EXISTING BASEBOARD RADIATOR AND BRANCH PIPING, AND PROVIDE CAP AT PIPE MAINS, AS INDICATED. 4 CAP EXISTING BASEBOARD RADIATION BRANCH PIPING AT GRADE. ALL EXISTING HEATING WATER PIPING BELOW GRADE SHALL BE ABANDONED. (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) 5 REMOVE EXISTING HEATING WATER RETURN AND HEATING WATER SUPPLY PIPING, AND PROVIDE CAP AT PIPE MAINS, AS INDICATED. 6 REMOVE EXISTING POOL HEATING WATER RETURN AND HEATING WATER SUPPLY PIPING, AND PROVIDE CAP AT PIPE MAINS, AS INDICATED. 7 REMOVE EXISTING UNIT HEATER. BRANCH PIPING OF SIZE AND TYPE INDICATED SHALL REMAIN FOR REUSE. REFER TO SHEET M204 FOR NEW WORK REQUIREMENTS. E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EB EC EC ED ED EE EE EF EF EG EG Eh Eh REMOVE EXISTING POOL WATER HEATING SYSTEM ASSOCIATED WITH (E)PDU-1 AS PART OF ALTERNATE #2. CAP POOL WATER PIPING AT POOL WATER SUPPLY AND RETURN LINES SERVING EXISTING HEAT EXCHANGER. REMOVE EXISTING PUMP. FCU BBR BBR BBR BBR BBR BBR BBR BBR BBR (E)2 1/2"(E)2 1/2" HWR HWS PWS PWR BBR 3/4" (E)2 1/2" 1/2" 1/2" 3/4" 1/2"HWS HWR 1/2"HWR 2 1/2" HWS & HWR UP TO PDU-1 ABOVE 3" PWS & PWR UP TO PDU ABOVE 6 HWR HWS (E)2 1/2" W. TEAM LOCKERS A106 EXIST POOL DECK A109 EXIST LAUNDRY A111EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST CHEM A115 EXIST NATATORIUM A110 M. TEAM LOCKER A107 STORAGE A105 3"3" PWS PWR 5 6 (E)1/2" (E)1/2"(E)1/2" BBR BBR The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 0 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC PIPING DEMOLITION PLAN - SOUTH MD204 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC PIPING DEMOLITION PLAN - SOUTH SCALE: 1/8" = 1'-0" ADD ALTERNATE #2 MAIN LEVEL HVAC PIPING DEMO PLAN DN A B C DN LOWER LEVEL HVAC PLAN KEYNOTES: (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) 1 VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS, TYPICAL. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. 4 CEILING MOUNTED EXHAUST FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 5 CEILING MOUNTED TRANSFER FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 6 FIRE/SMOKE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE THROUGH TRANSFER AIR GRILLE. REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 7 DUCTWORK OF SIZE AND TYPE INDICATED UP TO MAIN LEVEL. REFER TO SHEET M103 FOR CONTINUATION.8 DUCTWORK OF SIZE AND TYPE INDICATED UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION.9 RETURN AIR OPENING, OF SIZE INDICATED, IN TOP OF DUCTWORK. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR RETURN AIR PATH. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. BALANCE TO AIRFLOW INDICATED. 10 TRANSFER AIR DUCTWORK ABOVE CEILING THROUGH FULL HEIGHT WALL, OF SIZE INDICATED.11 TRANSFER AIR OPENING ABOVE CEILING THROUGH FULL HEIGHT WALL, OF SIZE INDICATED. MULTIPLE OPENINGS ARE ACCEPTABLE IF COMBINED AREAS TOTAL INDICATED AREA. 12 KITCHEN HOOD, AS INDICATED. REFER TO SCHEDULE ON SHEET M703. REFER TO ARCHITECTURAL DRAWINGS FOR REQUIREMENTS. 13 CEILING MOUNTED EXHAUST FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 14 KITCHEN HOOD FAN MOUNTED ON EXTERIOR WALL, AS INDICATED. REFER TO SCHEDULE ON SHEET M701.15 TRANSFER AIR DUCTWORK OF SIZE INDICATED THROUGH FULL HEIGHT WALL. PROVIDE OPEN ENDED MITERED ELBOWS, WITHOUT TURNING VANES ON EACH END OF DUCTWORK FOR SOUND ATTENUTION. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR TRANSFER AIR PATH. 16 14"ø TRANSFER AIR DUCTWORK SHALL ELBOW UP AND TERMINATE OPEN ENDED. PAINT INSIDE OF ELBOW BLACK. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. 17 MOTORIZED DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.18 BACKDRAFT DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.19 TRANSFER GRILLE OVERSIZED TO ACCOMODATE 'OUT OF AIRSTREAM' TYPE FIRE/SMOKE DAMPER, AS INDICATED.20 MP GROUP EX 124 ELEV 117 EMP ENTRY 103 COMMUNITY KITCHEN 142 KITCHEN 112 VEST 101 WOMEN 104 COMMUNITY 141 EXIT STAIR S10 GYM 131 GYM STORAGE 132 STORAGE 143 2 A B 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F G A2 A3 AG AF AA 6.4 CLASSROOM 114 WOMEN 111 STAFF 107 STAIR 120 MEN 110 RECV & STOR 115 STOR 113 STRENGTH 123 MEN 105 GAMES 106 ELEC 109 JR GOLF 121 STORAGE 118 LOUNGE 102 P&R DIRECTOR 108 1VAV-3-10 VAV-3-11 1VAV-3-12 VAV-3-131 VAV-3-171 VAV-3-16 1VAV-3-18 VAV-3-15 VAV-3-14 VAV-3-191 1VAV-3-20 VAV-3-22 VAV-3-21 20x18 SA 46x26 SA 18x16 SA 44x24 SA 12x10 SA 14x12 S A 18x18 S A 20x18 S A 14x14 S A 16"ø SA 44x22 SA 14x12 EA 26x18 44x22 S A 10"ø EG-2 225 CFM TYP.(2) 4x4 SG-2 25 CFM 10"ø CD-1 310 CFM TYP.(2) 2UH-4 8"ø CD-1 150 CFM 6"ø CD-1 50 CFM6"ø CD-1 50 CFM 8"ø CD-1 125 CFM TYP.(2) 8"ø CD-1 135 CFM 12x12 EA TF-26 CUH-33 10"ø CD-1 260 CFM TYP.(2) 8"ø CD-1 175 CFM 8"ø CD-1 200 CFM RG-4 RG-3 RG-1 RG-2 RG-3 2UH-5 CUH-53 32x11210 40x5210 46x26 SA8 46x32 RA8 46 x 3 2 R A 44 x 1 6 10x10 SA 18 x 1 6 S A 10"ø EG-2 225 CFM TYP.(2) 10"ø 10"ø 10"ø EA10"ø EA 16 " ø S A 16 " ø S A 8"ø EG-2 150 CFM 8"ø EG-2 150 CFM 12x12 EA 9 12x12 EG-4 550 CFM 12x14 EA9 10"ø EA9 3CUH-4 HITTING 122 STOR. 180 14x14 S A 6"ø CD-1 40 CFM 16x14 S A 14x12 S A20x18 S A 9 10 L 8 K 7.9 A.1 B.7 H J J.3 10"ø CD-1 350 CFM TYP.(2) 10"ø CD-1 285 CFM TYP.(6) 8"ø CD-1 205 CFM 8"ø CD-1 170 CFM 16x12 SA 36x28 RA DN DN 4 6 x 2 2 R A 16x12 SA 40 x 1 8 S A 4"ø SA 8"ø SA16x16 SA 12x12 EA 14"ø S A 10"ø CD-1 285 CFM TYP.(3) 14"ø SA 12x6 SR-2 285 CFM ANGLE DN. 45° 12"ø SA 12x6 SR-2 285 CFM ANGLE DN. 45° TYP.(2) 10"ø SA 8x8 SA 36x24 13 36x24 TG-136x24 TG-1 36x24 TG-1 6x6 SG-2 100 CFM 12"ø SA 10x6 SR-4 220 CFM HORIZONTAL TYP.(5) 40x18 SA 10"ø CD-1 350 CFM TYP.(2) 10"ø SD-1 235 CFM TYP.(6) 10"ø SD-1 320 CFM TYP.(6) 10"ø SD-1 285 CFM TYP.(6) 10"ø CD-1 235 CFM TYP.(2) RG-2 TYP.(3) RG-2 TYP.(3) RG-2 TYP.(3) 30x24 12 RG-2 68x24 12 RG-4 68x3612 50x50 TG-1 10x10 EA8 6"ø CD-1 100 CFM UP 7 16x16 TA 16x16 16x16 TG-1 16x16 TA 11 125 18x6 SR-2 320 CFM ANGLE DN. 20° TYP.(3) 18x6 SR-2 320 CFM ANGLE DN. 45° TYP.(4) 18x6 SR-2 320 CFM ANGLE DN. 45° 1 M301 1 M301 10"ø CD-1 285 CFM TYP.(2) 10"ø CD-1 350 CFM 46x22 RA UP UPDN 44x24 SA D N DN 46x32 RA 4 M301 8"ø EA9 13KH-1 8"ø EA 14EF-13 10"ø EA EF-1614 8"ø EA 15 16"ø SA 10x10 SG-2 260 CFM 16x16 TG-1 16x16 TA11 48x18 TA 16 48x18 TA 16 48x18 TA16 14"ø TG-3 TYP.(6) 17 17 17 RG-4 RG-4 M M 18 18 B 19 M 18 16x16 TG-1 16x18 TG-1 20 6x4 SG-2 50 CFM 6x4 UP The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 1 4 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 LOWER LEVEL HVAC PLAN M102 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" LOWER LEVEL HVAC PLAN A B C MAIN LEVEL HVAC PLAN KEYNOTES: (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL, TYPICAL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 1 HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. REFER TO PLUMBING PLANS FOR CONDENSATE DRAIN. 4 CEILING MOUNTED EXHAUST FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 5 CEILING MOUNTED TRANSFER FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 6 HIGH VOLUME LOW SPEED CEILING FAN SUPPORTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO SCHEDULE ON SHEET M701. 7 DUCTWORK OF SIZE AND TYPE INDICATED DOWN TO LOWER LEVEL. REFER TO SHEET M102 FOR CONTINUATION. 8 DUCTWORK OF SIZE AND TYPE INDICATED UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION.9 10 RETURN AIR OPENING OF SIZE INDICATED IN TOP OF DUCTWORK. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR RETURN AIR PATH. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. BALANCE TO AIRFLOW INDICATED. 10 DUCTWORK OF SIZE AND TYPE INDICATED THROUGH EXTERIOR WALL PENETRATION. SEAL AIR AND WATER TIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR WALL FLASHING DETAILS. REFER TO SHEET M105 FOR CONTINUATION. 11 POOL SKIN EXHAUST LOUVER, AS INDICATED. LOUVER SHALL BE ALIGNED WITH CMU BLOCK COURSING AND LOCATED MAXIMUM OF 8" ABOVE 12" CMU BLOCK WALL. 12 32"x40" AND 32"x30" SUPPLY AIR DUCTWORK UP IN NESTED FITTING TO 32"x70" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 13 38"x32" AND 46"x32" RETURN AIR DUCTWORK UP IN NESTED FITTING TO 84"x32" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 14 PERFORATED DUCTWORK, AS INDICATED. REFER TO SCHEDULE ON SHEET M702.15 FIRE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM NORTH SIDE OF WALL. REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 16 CONNECT 32"x12" COMBUSTION AIR INTAKE DUCTWORK TO EXISTING 32"x12" DUCTWORK AND ROUTE UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. REFER TO SECTION ON SHEET M301. 17 RETURN AIR LOUVER, AS INDICATED. SET BOTTOM AT 8" A.F.F. REFER TO SECTION ON SHEET M302. REFER TO SCHEDULE ON SHEET M702. 18 ADD ALTERNATE #2 - HIGH VOLUME LOW SPEED CEILING FAN SUPPORTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO SCHEDULE ON SHEET M701. 19 MOTORIZED DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.20 20"x28" AND 20"x24" SUPPLY AIR DUCTWORK UP IN NESTED FITTING TO 20"x52" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 22 12"ø AL29-4C FLUE FROM POOL HEATER UP THROUGH ROOF. FLUE SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. SLOPE FLUE BACK TO POOL HEATER AT 1/4" PER FOOT. DO NOT PROVIDE ANY DUCTWORK THAT IS ANGLED LESS THAN 45 DEGREES FROM HORIZONTAL. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 23 12"ø SINGLE WALL COMBUSTION AIR DUCTWORK FROM POOL HEATER UP THROUGH ROOF. DUCTWORK SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. INSULATE DUCTWORK WITH 1" DUCT WRAP UP TO ROOF DECK. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 24 FIRE/SMOKE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM ROOM '270 STAIR.' REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 25 16"ø EXISTING DRYER OUTSIDE AIR INTAKE DUCTWORK UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 26 6"ø CPVC CHEMICAL EXHAUST PIPING FROM CHEMICAL EXHAUST FAN UP THROUGH ROOF. CHEMICAL EXHAUST FAN IS BY DIVISION 13. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR FAN REQUIREMENTS. 27 TRANSFER AIR OPENING ABOVE CEILING THROUGH FULL HEIGHT WALL, OF SIZE INDICATED. MULTIPLE OPENINGS ARE ACCEPTABLE IF COMBINED AREAS TOTAL INDICATED AREA. 28 TRANSFER AIR OPENING OF SIZE INDICATED IN TOP OF DUCTWORK. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR TRANSFER AIR PATH. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. 29 21 TRANSFER AIR GRILLE MOUNTED APPROXIMATELY 6" BELOW ROOF DECK, AS INDICATED. BACKDRAFT DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.30 14"ø TRANSFER AIR DUCTWORK SHALL ELBOW UP AND TERMINATE OPEN ENDED. PAINT INSIDE OF ELBOW BLACK. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. 31 EXHAUST GRILLE OVERSIZED TO ACCOMODATE 'OUT OF AIRSTREAM' TYPE FIRE/SMOKE DAMPER, AS INDICATED.32 FIRE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM SOUTH SIDE OF WALL. REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 33 REFER TO ROOF HVAC PLAN FOR EQUIPMENT LOCATED ON THIS LOW ROOF AREA. ST. 263 56 SF 2 A B 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F G A2 A3 AG AF AA 6.4 VESTIBULE 201 LOBBY 202 CARDIO 261 MEN 203 WOMEN 204 ADMIN 271 EXEC DIR 281 ASST 279 WATER & FIRE ENTRY 273 IT 274 HR 283 FACILITY DIR 285 FINANCE 287 TEMP 284 COPY 278 LAN 276 MARKET 277 CONFERENCE 275 ELEC 282 DSIU-14 M/P GROUP EX 262 DESK STAFF 272 VAV-3-1 VAV-3-2 VAV-3-3 VAV-3-6 VAV-3-5 VAV-3-41 TF-16 5EF-8 5EF-7 1VAV-3-8 1VAV-3-9 VAV-3-71 38 " ø S A 24"ø SA24"ø SA 32 " ø S A 24"ø SA24"ø SA 24x16 30x32 SA 24x18 SA 16x14 S A 10x12 12x10 SA 12x8 SA 10"ø SA 12x10 SA 12x10 SA 18 " ø S A 38x32 RA 40"ø RA 8"ø CD-1 180 CFM 6"ø CD-1 105 CFM 6"ø CD-1 100 CFM 10"ø CD-1 320 CFM 6"ø CD-1 140 CFM 6"ø CD-1 110 CFM 10"ø CD-1 225 CFM TYP.(2) 4x4 SG-2 35 CFM 6x6 SG-2 75 CFM 4"ø SA 6"ø SA RG-3 RG-4 RG-3 RG-3 RG-3 RG-3 RG-3 8"ø CD-1 135 CFM 6"ø CD-1 60 CFM 12x12 TA 6"ø CD-1 120 CFM 6"ø CD-1 120 CFM 6"ø CD-1 85 CFM 6"ø CD-1 85 CFM RG-4 RG-3 RG-3 10"ø CD-1A 240 CFM 10"ø CD-1A 240 CFM 24x16 RA 46x32 RA 40x32 SA 6x10 SA 34x90 10 20x44 10 EG-1 350 CFM 10x10 EA 8 10x10 EA 9 8x8 EA 9 8x8 EA9 40x40 SA 9 40"ø RA 9 RD-1 13 14 16x14 SA 10x10 EA 15 24 x 1 6 R A 24x16 SA VAV-3-23 14 x 1 4 S A 10x10 SA 9 10 L 8 K 7.9 A.1 B.7 H J J.3 18x12 SR-2 845 CFM ANGLE DN. 45° TYP.(4) 18x12 SR-2 845 CFM ANGLE DN. 45° TYP.(4) 10x4 SR-4 175 CFM ANGLE DN. 45° TYP.(21) 14"ø SA 20 " ø S A 24"ø SA 24 " ø S A 18x12 SR-2 845 CFM ANGLE DN. 45° TYP.(4) 12x6 SR-2 290 CFM ANGLE DN. 30° TYP.(6) 12x6 SR-2 290 CFM ANGLE DN. 30° 20 " ø S A 18 " ø S A 16 " ø S A 12 " ø S A RG-3 46x26 SA 8"ø CD-1 205 CFM TYP.(5) EXIT STAIR S10 STAIR 270 22 " ø S A 38x24 UP 58x42 TA 20"ø SA 8x14 SA VAV-3-24 12x12 EA 9 12x14 EG-1 750 CFM 54x46 29 54x46 29 6"ø CD-1 40 CFM 6"ø CD-2 60 CFM6x6 SA 4x6 ST. 263a EXIT STAIR S20 D N 8"ø CD-1 185 CFM TYP.(3) 10"ø CD-1 335 CFM TYP.(8) RG-2 TYP.(2) RG-2 TYP.(2) 70x36 TG-1 21 70x36 TG-1 212170x36 TG-1 18x12 SR-2 845 CFM ANGLE DN. 45° TYP.(4) 125 CF-27 CF-17 1 M301 1 M301 32"ø SA MATCHLINE M104 M103 12x1225 UH-12 46x26 SA846x32 RA8 M 20 M 20 M 20 M 20 B 30 6 M301 12x12 EA 32 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 2 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC PLAN - NORTH M103 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC PLAN - NORTH MAIN LEVEL HVAC PLAN KEYNOTES: (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL, TYPICAL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 1 HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. REFER TO PLUMBING PLANS FOR CONDENSATE DRAIN. 4 CEILING MOUNTED EXHAUST FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 5 CEILING MOUNTED TRANSFER FAN, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 6 HIGH VOLUME LOW SPEED CEILING FAN SUPPORTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO SCHEDULE ON SHEET M701. 7 DUCTWORK OF SIZE AND TYPE INDICATED DOWN TO LOWER LEVEL. REFER TO SHEET M102 FOR CONTINUATION. 8 DUCTWORK OF SIZE AND TYPE INDICATED UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION.9 10 RETURN AIR OPENING OF SIZE INDICATED IN TOP OF DUCTWORK. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR RETURN AIR PATH. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. BALANCE TO AIRFLOW INDICATED. 10 DUCTWORK OF SIZE AND TYPE INDICATED THROUGH EXTERIOR WALL PENETRATION. SEAL AIR AND WATER TIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR WALL FLASHING DETAILS. REFER TO SHEET M105 FOR CONTINUATION. 11 POOL SKIN EXHAUST LOUVER, AS INDICATED. LOUVER SHALL BE ALIGNED WITH CMU BLOCK COURSING AND LOCATED MAXIMUM OF 8" ABOVE 12" CMU BLOCK WALL. 12 32"x40" AND 32"x30" SUPPLY AIR DUCTWORK UP IN NESTED FITTING TO 32"x70" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 13 38"x32" AND 46"x32" RETURN AIR DUCTWORK UP IN NESTED FITTING TO 84"x32" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 14 PERFORATED DUCTWORK, AS INDICATED. REFER TO SCHEDULE ON SHEET M702.15 FIRE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM NORTH SIDE OF WALL. REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 16 CONNECT 32"x12" COMBUSTION AIR INTAKE DUCTWORK TO EXISTING 32"x12" DUCTWORK AND ROUTE UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. REFER TO SECTION ON SHEET M301. 17 RETURN AIR LOUVER, AS INDICATED. SET BOTTOM AT 8" A.F.F. REFER TO SECTION ON SHEET M302. REFER TO SCHEDULE ON SHEET M702. 18 ADD ALTERNATE #2 - HIGH VOLUME LOW SPEED CEILING FAN SUPPORTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO SCHEDULE ON SHEET M701. 19 MOTORIZED DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.20 20"x28" AND 20"x24" SUPPLY AIR DUCTWORK UP IN NESTED FITTING TO 20"x52" UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 22 12"ø AL29-4C FLUE FROM POOL HEATER UP THROUGH ROOF. FLUE SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. SLOPE FLUE BACK TO POOL HEATER AT 1/4" PER FOOT. DO NOT PROVIDE ANY DUCTWORK THAT IS ANGLED LESS THAN 45 DEGREES FROM HORIZONTAL. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 23 12"ø SINGLE WALL COMBUSTION AIR DUCTWORK FROM POOL HEATER UP THROUGH ROOF. DUCTWORK SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. INSULATE DUCTWORK WITH 1" DUCT WRAP UP TO ROOF DECK. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 24 FIRE/SMOKE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM ROOM '270 STAIR.' REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 25 16"ø EXISTING DRYER OUTSIDE AIR INTAKE DUCTWORK UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 26 6"ø CPVC CHEMICAL EXHAUST PIPING FROM CHEMICAL EXHAUST FAN UP THROUGH ROOF. CHEMICAL EXHAUST FAN IS BY DIVISION 13. REFER TO SHEET M105 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR FAN REQUIREMENTS. 27 TRANSFER AIR OPENING ABOVE CEILING THROUGH FULL HEIGHT WALL, OF SIZE INDICATED. MULTIPLE OPENINGS ARE ACCEPTABLE IF COMBINED AREAS TOTAL INDICATED AREA. 28 TRANSFER AIR OPENING OF SIZE INDICATED IN TOP OF DUCTWORK. ENSURE 10" CLEAR SPACE ABOVE OPENING FOR TRANSFER AIR PATH. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. 29 21 TRANSFER AIR GRILLE MOUNTED APPROXIMATELY 6" BELOW ROOF DECK, AS INDICATED. BACKDRAFT DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.30 14"ø TRANSFER AIR DUCTWORK SHALL ELBOW UP AND TERMINATE OPEN ENDED. PAINT INSIDE OF ELBOW BLACK. PROVIDE 1/2" BIRD SCREEN ACROSS OPENING. 31 EXHAUST GRILLE OVERSIZED TO ACCOMODATE 'OUT OF AIRSTREAM' TYPE FIRE/SMOKE DAMPER, AS INDICATED.32 FIRE DAMPER AT RATED WALL IN DUCTWORK OF SIZE INDICATED. DAMPER ACCESS SHALL BE FROM SOUTH SIDE OF WALL. REFER TO SPECIFICATION SECTION 23 30 00 FOR FURTHER REQUIREMENTS. 33 3CUH-1 7CF-3 (E)26"ø SA (E)24"ø SA (E)22"ø SA (E)18"ø SA CUH-23 2UH-2 ACTIVITY POOL 001 POOL MECH 253 POOL OFFICE 256 W. LOCKERS 221 FAM CHANGING 212 PARTY 211 INDOOR PLAY 205 W. TEAM LOCKERS A106 M. LOCKERS 231 EXIST POOL DECK A109 MATCHLINE M103 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF 2 EG Eh 1 3 4 6 76.4 FOYER A101 W. SHOWERS 222 W. TOILETS 223 M. TOILETS 233 M. SHOWERS 232 JAN 229 ACR2 214 CHG 215 ACR3 216 VESTIBULE 201 EXIST LAUNDRY A111 EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST CHEM A115 EXIST NATATORIUM A110 POOL STORAGE A108 M. TEAM LOCKER A107 MECHANICAL A102 POOL STORAGE 255 CIRC 259 OFFICE 206 KIDS T 207 KID WATCH 288 ELEC 254 ACR1 213 GUARD CHG 257 GUARDS 258 ALT WATER SLIDE 002 VA V - 2 - 4 VAV-2-3 1VAV-2-2 VAV-2-1 1VAV-2-5 VAV-2-6 1VAV-2-7 VAV-2-9 VAV-2-8 36 " ø S A 18x14 SA 14x14 SA 10x12 SA 20x12 SA 10x12 SA 2UH-3 TF-36 EF-35 6"ø CD-1 75 CFM 10"ø CD-1 250 CFM 6"ø CD-1 100 CFM 8"ø SA 6"ø CD-1 50 CFM 6"ø CD-1 50 CFM 10"ø CD-1 250 CFM 6"ø CD-1 50 CFM 26x16 SA 10x8 EA 18 x 1 8 E A 64x72 LVR-2 9,570 CFM 64x72 LVR-3 9,570 CFM 10x10 TA (E)32"ø SA (E)16x14 EA (E)14x12 EA (E)44"ø SA 44x44 SA11 RG-1 8x6 EA 10"ø SD-2 225 CFM 10"ø CD-1 225 CFM 6"ø CD-1 50 CFM 6"ø CD-1 40 CFM 14x12 SA 10x10 SA 8"ø SA8"ø SA 10"ø CD-1 280 CFM TYP.(2) M401 1 6"ø EA 10"ø EA 10"ø EA 10"ø CD-1 250 CFM 44 x 1 8 R A 44x18 RA 52x24 RA 9 (E)14x16 EA 9 6x8 EA9 18x18 EA 9 26x16 SA 9 8x10 EA 9 16x14 EA 9 8"ø EG-2 150 CFM 8"ø EG-2 150 CFM 8"ø EG-2 150 CFM 6"ø EG-2 100 CFM 10"ø EG-2 300 CFM TYP.(2) 10"ø EG-2 250 CFM TYP.(3) STORAGE A105 M. LOCKERS 2 A103 6"ø EG-2 100 CFM 8x6 EG-1 100 CFM 24 x 1 8 S A 16 x 1 4 E A 10"ø EG-2 300 CFM TYP.(2) Q 9 10 L P M 8 M.6 N 7.9 NJ 24x18 SA 20 x 1 6 S A 28x20 SA 18x14 SA 8"ø CD-1 200 CFM TYP.(2) DN 6x8 SA 14"ø SA 10x6 SR-4 225 CFM TYP.(4) 52x24 RA 10x10 8x8 EA 10x12 SA 10"ø CD-1 275 CFM TYP.(2) 10"ø CD-1 325 CFM TYP.(2) 8x8 SG-1 220 CFM TYP.(2) 12x12 EG-1 500 CFM 6"ø CD-1 100 CFM 10"ø CD-1 250 CFM 6"ø CD-1 120 CFM 8"ø CD-1 200 CFM 10"ø CD-1 250 CFM 14 x 1 2 S A 12 x 1 2 S A 10"ø CD-1 300 CFM TYP.(2) 6"ø CD-1 150 CFM 8"ø CD-1 200 CFM 18x50 RA9 8"ø CD-1 150 CFM 8"ø CD-1 150 CFM TYP.(2) 6"ø CD-1 130 CFM 8"ø CD-1 200 CFM 10"ø EG-2 260 CFM TYP.(3) 8"ø EA 10"ø EA 10"ø EA 10"ø EA 24x12 EG-3 1,000 CFM TYP.(2) 10x8 EG-1 300 CFM 10x10 TG-1 450 CFM 42"ø SA 50 x 1 8 R A 32"ø SA 36"ø SA 40x40 SA 11 12"ø24 4"ø 27 24x14 SG-1 1,050 CFM TYP.(2) 4"ø 27 12"ø23 56x48 LVR-4 7,100 CFM 14 " ø S A 1 2 " ø S A 6"ø CD-1 35 CFM LOBBY 202 VESTIBULE A104 10x10 SG-2 480 CFM 8"ø SG-3 240 CFM TYP.(4) 8"ø EG-2 210 CFM TYP.(2) 1168x56 RA (E)8"ø FLUE 9 (E)8"ø FLUE 12 NATORIUM 251 72x104 LVR-1 17,200 CFM 26 x 1 6 S A (E)30"ø SA 30"ø SR-3 500 CFM 6x6 SG-1 125 CFM 6x6 SA 5 2 M302 1 M302 20x10 20x10 SA 24x10 SR-1 980 CFM ANGLE DN. 45° TYP.(4) 64x72 RA UP 22 DN DN (E)16"ø DRYER OA 26 3 M301 M104 32x12 CA 17 18 18 3 M302 DN 10x10 SG-1 400 CFM 8"ø SA 8"ø SA 32"ø SA 24"ø SA RG-2 10x10 SG-1 400 CFM 19CF-4A 19CF-5A 14 x 1 0 E A 18 x 1 6 20x6 EA 10x8 SA 10"ø SA 12"ø SA 8"ø CD-1 200 CFM 8"ø CD-1 200 CFM 8"ø TG-2 200 CFM TYP.(2) 8"ø TA 8"ø SA 8"ø SA 20x14 18x16 EA9 10"ø EG-2 250 CFM TYP.(3) 10"ø SA 10"ø EA 6"ø 18x14 SA 44x18 RA 10"ø EA TYP.(3) 8"ø EA 6"ø 8"ø EA 8"ø 10"ø EA 10"ø EA 10"ø EA (E)10x10 EA B 30 B 30 M 20 B 30 B 30 M 20 12x12 EA 9 B 30 12 x 1 2 S A 12"ø SA 8"ø SA 31 31 14"ø TG-3 14"ø TG-3 20x10 16 10"ø16 20x616 20x6 EA UP10x12 SA 7 M301 20x6 33 DN DN DN DN DN DN UP (E)38"ø SA 24x10 SR-1 980 CFM ANGLE DN. 80° TYP.(4) 24x10 SR-1 980 CFM ANGLE DN. 60° 24x10 SR-1 980 CFM ANGLE DN. 60° TYP.(3) 24x10 SR-1 980 CFM ANGLE DN. 60° 24x10 SR-1 980 CFM ANGLE DN. 60° TYP.(2) (E)EG 200 CFM The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 3 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC PLAN - SOUTH M104 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC PLAN - SOUTH E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF 2 A B EG Eh 1 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F G A2 A3 AG AF AA 6.4 EF-93 DSCU-14 3EF-10 EF-123 EF-63 EF-23EF-13 RTU-31 RTU-11 (E)PDU-1 EF-53 EF-43 EF-113 6MAU-1 7 7 8 (E)44x44 SA (E)56x68 RA Q 9 10 L P M 8 M.6 K N 7.9 NJ A.1 B.7 H J J.3 40x40 SA 9 RTU-21 PDU-22 7 4"ø 16 4"ø 16 12"ø1312"ø 12 40x32 EA 25 17SA-1 4"ø 20 4"ø 21 4"ø 18 4"ø20 4"ø 21 4"ø 19 4"ø20 4"ø21 4"ø184"ø18 4"ø194"ø19 7 22 (E)8"ø FLUE 68x56 RA 16"ø OA 23 EF-1428 3EF-15 125 32x12 CA 26 27 27 27 27 27 27 27 27 27 27 27 27 3EF-17 8x8 EA88x8 EA8 8"ø EA8 10"ø EA8 ROOF HVAC PLAN KEYNOTES: ROOF TOP UNIT MOUNTED ON 6" CONCRETE PAD AND 14" ROOF CURB, AS INDICATED. ROOF CURB TO MATCH ROOF SLOPE. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. (NOTE: ALL KEYNOTES MAY NOT APPLY TO EACH SHEET) 1 POOL DEHUMIDIFICATION UNIT MOUNTED ON 6" CONCRETE PAD AND 14" ROOF CURB, AS INDICATED. ROOF CURB TO MATCH ROOF SLOPE. REFER TO SCHEDULE ON SHEET M701. 2 EXHAUST FAN MOUNTED ON 14" ROOF CURB, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 3 DUCTLESS SPLIT SYSTEM CONDENSING UNIT, AS INDICATED. MOUNT UNIT AND CURB ON 6" CONCRETE PAD. PAD SHALL EXTEND PAST UNIT FOOTPRINT 4" IN ALL DIRECTIONS. REFER TO SCHEDULE ON SHEET M702. 4 CHEMICAL EXHAUST FAN MOUNTED ON 14" ROOF CURB, AS INDICATED. REFER TO SCHEDULE ON SHEET M701.5 MAKE-UP AIR UNIT MOUNTED ON 14" ROOF CURB, AS INDICATED. REFER TO SCHEDULE ON SHEET M701.6 DASHED LINE REPRESENTS UNITS CLEARANCE REQUIREMENTS, TYPICAL.7 DUCTWORK OF SIZE AND TYPE INDICATED UP THROUGH ROOF SHALL TERMINATE WITH GOOSENECK, AS INDICATED. REFER TO DETAIL ON SHEET M501. 8 DUCTWORK OF SIZE AND TYPE INDICATED THROUGH EXTERIOR WALL PENETRATION. SEAL AIR AND WATER TIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR WALL FLASHING DETAILS. REFER TO SHEET M104 FOR CONTINUATION. 9 DUCTWORK OF SIZE AND TYPE INDICATED DOWN THROUGH ROOF. REFER TO SHEET M104 FOR CONTINUATION. 10 ROOF MOUNTED INSULATED DUCTWORK OF SIZE AND TYPE INDICATED SHALL BE INSTALLED 18" (MINIMUM) ABOVE ROOF ON PRE-FABRICATED PHP ROOF DUCT SUPPORTS THAT ADHERE TO ROOFING SURFACE, PER S.M.A.C.N.A. STANDARDS. WRAP DUCTWORK IN 2" RIGID INSULATION WITH ALUMINUM WEATHER RESISTANT JACKETING. SLOPE TOP OF INSULATION TO PREVENT WATER PONDING. REFER TO DETAIL ON SHEET M501. 11 12"ø AL29-4C FLUE UP FROM POOL HEATER BELOW SHALL TERMINATE WITH BRIEDERT STYLE FLUE CAP PER DETAIL ON SHEET M501. FLUE SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M104 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 12 12"ø SINGLE WALL COMBUSTION AIR DUCTWORK UP FROM POOL HEATER SHALL TERMINATE PER DETAIL ON SHEET M501. DUCTWORK SIZE IS BASED ON 1,440 MBH INPUT POOL HEATER. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M104 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 13 6"ø AL29-4C FLUE UP FROM POOL HEATER SHALL TERMINATE WITH BRIEDERT STYLE FLUE CAP PER DETAIL ON SHEET M501. FLUE SIZE IS BASED ON 650 MBH INPUT POOL HEATER. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M104 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 14 6"ø COMBUSTION AIR DUCTWORK UP FROM POOL HEATER SHALL TERMINATE PER DETAIL ON SHEET M501. DUCT SIZE IS BASED ON 650 MBH INPUT POOL HEATER. VERIFY SIZING, MATERIAL AND ROUTING REQUIREMENTS WITH SUCCESSFUL POOL HEATER MANUFACTURER. PRIOR TO PURCHASE, SUBMIT VENT SYSTEM ROUTING SCHEMATIC BASED ON FIELD CONDITIONS FOR ENGINEER'S REVIEW. REFER TO SHEET M104 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR POOL HEATER REQUIREMENTS. 15 6"ø CPVC CHEMICAL EXHAUST PIPING UP FROM CHEMICAL EXHAUST FAN BELOW. TERMINATE WITH GOOSENECK FITTING 3'-0" ABOVE ROOF SURFACE PER DETAIL ON SHEET M501. REFER TO SHEET M104 FOR CONTINUATION. REFER TO AQUATICS PLANS FOR CHEMICAL EXHAUST FAN REQUIREMENTS. 16 SOUND ATTENUATOR, AS INDICATED. REFER TO SCHEDULE ON SHEET M702.17 FLUE OF SIZE INDICATED UP FROM WATER HEATER BELOW. TERMINATE PER MANUFACTURER'S REQUIREMENTS. REFER TO SHEET M104 FOR CONTINUATION. REFER TO DETAIL ON SHEET M501. 18 COMBUSTION AIR VENT PIPING OF SIZE INDICATED UP THROUGH ROOF FROM WATER HEATER BELOW. TERMINATE PER MANUFACTURER'S REQUIREMENTS. REFER TO SHEET M104 FOR CONTINUATION. REFER TO DETAIL ON SHEET M501. 19 FLUE OF SIZE INDICATED UP THROUGH ROOF FROM BOILER BELOW. TERMINATE PER MANUFACTURER'S REQUIREMENTS. REFER TO SHEET M104 FOR CONTINUATION. REFER TO DETAIL ON SHEET M501. 20 COMBUSTION AIR VENT PIPING OF SIZE INDICATED UP THROUGH ROOF FROM BOILER BELOW. TERMINATE PER MANUFACTURER'S REQUIREMENTS. REFER TO SHEET M104 FOR CONTINUATION. REFER TO DETAIL ON SHEET M501. 21 REFRIGERANT SUCTION & REFRIGERANT LIQUID PIPING UP THROUGH ROOF FROM MAIN LEVEL. REFER TO SHEET M203 FOR CONTINUATION. 22 16"ø DRYER OUTSIDE AIR INTAKE VENT UP FROM BELOW SHALL TERMINATE WITH MANUFACTURER APPROVED ROOF CAP 36" ABOVE FINISHED ROOF, AS INDICATED. 23 DUCTWORK DROP SHALL BE A MINIMUM OF 4'-0" FROM PARAPET WALL TO ALLOW ROOF ACCESS BY WALKING UNDER DUCTWORK. REFER TO SECTION ON SHEET M302. 24 ROOF MOUNTED DUCTWORK OF SIZE AND TYPE INDICATED SHALL BE INSTALLED 18" (MINIMUM) ABOVE ROOF ON PRE- FABRICATED PHP ROOF DUCT SUPPORTS THAT ADHERE TO ROOFING SURFACE, PER S.M.A.C.N.A. STANDARDS. 25 DUCTWORK OF SIZE AND TYPE INDICATED UP THROUGH ROOF SHALL TERMINATE 36" ABOVE FINISHED ROOF WITH GOOSENECK FITTING. REFER TO SHEET M104 FOR CONTINUATION. REFER TO SECTION ON SHEET M301. REFER TO DETAIL ON SHEET M501. 26 ROOF PENETRATION THROUGH EXISTING ROOF. SEAL AIR AND WATER TIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF FLASHING DETAILS. 27 MOUNT EXHAUST FAN ON EXISTING ROOF CURB WITH 14" ADAPTER CURB, AND CONNECT TO EXISTING 14"x16" EXHAUST AIR DUCTWORK DOWN THROUGH ROOF, AS INDICATED. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 28 E10 E11 E12 E13 E14 EB EC ED EE EF EG Eh 6 76.4 Q 9 10 L P M 8 M.6 N 7.9 NJ EF-6 PDU-1 EF-5 EF-4 (E)44x44 SA 56x68 RA 40x40 SA RTU-2 PDU-2 40x32 EA SA-1 4"ø 4"ø 4"ø4"ø 4"ø 4"ø 4"ø 4"ø 4"ø4"ø 4"ø4"ø (E)68x56 RA EF-14 44x44 SA 2PDU-1A 38x38 RA11 36x36 SA 11 REMOVE EXISTING PDU AND ASSOCIATED DUCTWORK AS INDICATED. MAINTAIN EXISTING EXTERIOR DUCTWORK RISE & ENTRY INTO BUILDING. CONNECT NEW DUCTWORK TO BASE OF EXISTING EXTERIOR RISE. 36x36 SA 11 38x38 RA 11 MAINTAIN EXISTING DUCTWORK PENETRATION THROUGH WALL. CONNECT NEW DUCTWORK AS INDICATED. 24 24 EF-17 38x38 RA The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/16" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 4 8 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 ROOF HVAC PLAN M105 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/16" = 1'-0" ROOF HVAC PLAN SCALE: 1/16" = 1'-0" ADD ALTERNATE #2 ROOF HVAC PLAN DN A B C DN 2 A B 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F G A2 A3 AG AF AA 6.4 UH-42 1VAV-3-12 VAV-3-131 VAV-3-141 VAV-3-151 VAV-3-161 1VAV-3-18 1VAV-3-17 1VAV-3-11 1VAV-3-10 1 1/2"1 1/2" H W S H W R MP GROUP EX 124 STAIR 120 ? ? ELEV 117 EMP ENTRY 103 COMMUNITY KITCHEN 142 KITCHEN 112 VEST 101LOUNGE 102 WOMEN 104 COMMUNITY 141 EXIT STAIR S10 GYM 131 GYM STORAGE 132 P&R DIRECTOR 108 STORAGE 143 MEN 110 CLASSROOM 114 RECV & STOR 115 STOR 113 WOMEN 111 STRENGTH 123 MEN 105 GAMES 106 STAFF 107 ELEC 109 JR GOLF 121 HITTING 122 STORAGE 118 VAV-3-191 VAV-3-201 1VAV-3-21 1VAV-3-22 9 108 K 7.9 A.1 B.7 H J J.3 3CUH-3 CUH-43 2UH-5 CUH-53 T T T T T T T T T HW S HW R TO VAV-3-13 TO VAV-3-12 T T TO VAV-3-15 T TO VAV-3-16 T TO VAV-3-17 T T TO VAV-3-21 T TO VAV-3-19 T TO VAV-3-20 T TO VAV-3-22 2"5 2"5 2"2" 1 1/2"1 1/2" 1 1/2"1 1/2" 1 1/4"1 1/4" 1"1" 3/4"3/4" 1"1" 6 6 125 $ TO EF-13 1 1/4"1 1/4" 1"1" 1"1"1 1/4"1 1/4" TO CF-1 $ TO CF-2 $ TO RTU-1 T H 7 H HH H C O2 C O2 C O2 8 8 8 $ TO EF-10 $ TO EF-13 T TO TF-2 LOWER LEVEL HVAC PIPING PLAN KEYNOTES: (NOTE: NOT ALL KEYNOTES APPLY TO EACH SHEET) VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL, TYPICAL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 1 HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. 4 PIPING OF SIZE INDICATED UP TO MAIN LEVEL. REFER TO SHEET M203 FOR CONTINUATION.5 6 PROVIDE UNIT WITH 3-WAY CONTROL VALVE. 7 PROVIDE SENSOR WITH PROTECTIVE WIRE GUARD ENCLOSURE, AS INDICATED. 8 IN EVENT THAT C02 SENSOR IS NOT INTEGRAL TO TEMPERATURE SENSOR, CO2 SENSOR SHALL BE INSTALLED 2" ABOVE TEMPERATURE SENSOR TO PREVENT CO2 SENSOR HEAT FROM AFFECTING TEMPERATURE READING. The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 7 : 5 6 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 LOWER LEVEL HVAC PIPING PLAN M202 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" LOWER LEVEL HVAC PIPING PLAN A B C MAIN LEVEL HVAC PIPING PLAN KEYNOTES: (NOTE: NOT ALL KEYNOTES APPLY TO EACH SHEET) VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL, TYPICAL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 1 HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. 4 PIPING OF SIZE INDICATED DOWN TO LOWER LEVEL.5 REFRIGERANT SUCTION AND REFRIGERANT LIQUID PIPING UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 6 TEMPERATURE SENSOR MOUNTED ON WALL IN ELEVATOR SHAFT APPROXIMATELY 1'-0" BELOW ROOF DECK, AS INDICATED. ENSURE MOUNTING LOCATION DOES NOT INTERFERE WITH ELEVATOR OPERATION. 7 CONNECT TO EXISTING HEATING WATER SUPPLY AND RETURN PIPING. COORDINATE EXISTING HEATING WATER SYSTEM SHUTDOWN WITH OWNER OR PROVIDE HOT TAPS. 8 ADJACENT SPACE PRESSURE SENSOR. SET FLUSH WITH CEILING. T.C.C. TO SET SENSOR AND ROUTE TUBING TO PDU-2. NATATORIUM PRESSURE SENSOR, AS INDICATED. SET ON WALL AS HIGH AS POSSIBLE, APPROXIMATELY 22'-0". T.C.C. SHALL SET SENSOR AND ROUTE TUBING TO PDU-2. 11 PDU-2 REMOTE USER TERMINAL, AS INDICATED.12 PDU-2 PUSH BUTTON PURGE MODE SWITCH WITH PILOT LIGHT, BY T.C.C.13 CONNECT TO EXISTING HEATING WATER SUPPLY AND RETURN PIPING. COORDINATE EXISTING HEATING WATER SYSTEM SHUTDOWN WITH OWNER OR PROVIDE HOT TAPS. 9 10 ADD ALTERNATE #2 - ADJACENT SPACE PRESSURE SENSOR. SET FLUSH WITH CEILING. T.C.C. TO SET SENSOR AND ROUTE TUBING TO PDU-1A. 14 ADD ALTERNATE #2 - NATATORIUM PRESSURE SENSOR, AS INDICATED. SET ON WALL AS HIGH AS POSSIBLE, APPROXIMATELY 20'-0". T.C.C. SHALL SET SENSOR AND ROUTE TUBING TO PDU-1A. 15 ADD ALTERNATE #2 - PDU-1A PUSH BUTTON PURGE MODE SWITCH WITH PILOT LIGHT, BY T.C.C.17 ADD ALTERNATE #2 - PDU-1A REMOTE USER TERMINAL, AS INDICATED.16 IN EVENT THAT C02 SENSOR IS NOT INTEGRAL TO TEMPERATURE SENSOR, CO2 SENSOR SHALL BE INSTALLED 2" ABOVE TEMPERATURE SENSOR TO PREVENT CO2 SENSOR HEAT FROM AFFECTING TEMPERATURE READING. 18 M/P GROUP EX 262 ST. 263 EXIT STAIR S10 MATCH LINE M204 2 A B 3 4 6 7 A1 A4 AB A5 AE AD AH AC C D E F G A2 A3 AG AF AA 6.4 REFER TO ROOF HVAC PLAN FOR EQUIPMENT LOCATED ON THIS LOW ROOF AREA. MEN 203 WOMEN 204 ADMIN 271 DESK STAFF 272 EXEC DIR 281 ASST 279 WATER & FIRE ENTRY 273 IT 274 HR 283 FACILITY DIR 285 FINANCE 287 TEMP 284 COPY 278 LAN 276 MARKET 277 CONFERENCE 275 ELEC 282 2" 2" 3/4"3/4" DSIU-14 9 10 L 8 K 7.9 A.1 B.7 H J J.3 1VAV-3-1 VAV-3-31 VAV-3-41 1VAV-3-5 VAV-3-21 VAV-3-6 1VAV-3-9 2" 52" 5 VAV-3-71 1VAV-3-23 VAV-3-81 T T T T T TO VAV-3-7 T TO VAV-3-8 T T H W RHWS 1 1/4"1 1/4"1"1" 3/4"3/4" 6 T VAV-3-24 T TO EF-15 7 LOBBY 202 NATORIUM 251 CARDIO 261 HWS HWR 2 1/2"2 1/2" 2 1/2"2 1/2" H W RHWS 1 1/2"1 1/2" 125 T TO VAV-3-9 STAIR 270 ST. 263a EXIT STAIR S20 TO VAV-3-24 2"2" 2"2" TO VAV-3-5 TO VAV-3-6 TO VAV-3-4 TO VAV-3-3 TO VAV-3-2TO VAV-3-1 M203 UH-12 H OS TO EF-7 OS TO EF-8 $ TO EF-9 T TO TF-1 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 0 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC PIPING PLAN - NORTH M203 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC PIPING PLAN - NORTH M203 E1 E2 E3 E4 E5 E7 E8 E9 E10 E11 E12 E13 E14 EB EC ED EE EF 2 EG Eh 1 3 4 6 76.4 POOL MECH 253 POOL OFFICE 256 W. LOCKERS 221 FAM CHANGING 212 PARTY 211 INDOOR PLAY 205 W. TEAM LOCKERS A106 M. LOCKERS 231 FOYER A101 EXIST POOL DECK A109 W. SHOWERS 222 W. TOILETS 223 M. TOILETS 233 M. SHOWERS 232 JAN 229 ACR1 213 ACR2 214 CHG 215 ACR3 216 VESTIBULE 201 LOBBY 202 EXIST LAUNDRY A111 EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST CHEM A115 EXIST NATATORIUM A110 POOL STORAGE A108 M. TEAM LOCKER A107 MECHANICAL A102 POOL STORAGE 255 CIRC 259 OFFICE 206 KIDS T 207 KID WATCH 288 ELEC 254 GUARD CHG 257 GUARDS 258 ALT WATER SLIDE 002 (E)2 1/2"(E)2 1/2" HWR HWS PWS PWR (E)3"(E)3" (E)2 1/2"(E)2 1/2" (E)2 1/2" (E)2" CD UP TO (E)PDU ABOVE (E)2 1/2" HWS & HWR UP TO (E)PDU ABOVE (E)3" PWS & PWR UP TO (E)PDU ABOVE (E)3"(E)3" HW R HW S 1VAV-2-7 1VAV-2-9 VAV-2-61 VAV-2-41 1VAV-2-8 1VAV-2-3 1VAV-2-2 VAV-2-51 Q 9 10 L P M 8 M.6 N 7.9 NJ CUH-13 2UH-3 CUH-23 UH-22 VAV-2-11 T TO VAV-2-1 T TO VAV-2-2 T T T PWSPWR HWS HWR TO VAV-2-3 TO VAV-2-5 TO VAV-2-9 T T TT TT T T M401 1 ACTIVITY POOL 001 STORAGE A105 M. LOCKERS 2 A103 VESTIBULE A104 NATORIUM 251 2 1/2"2 1/2" HW R HW S HWR HWS 1"1" 3/4"3/4" 3/4"3/4" 1"1"1"1" 2 1/2"2 1/2" H W RHWS 5 TO VAV-2-4 TO VAV-2-6 TO VAV-2-8 VESTIBULE 201 VESTIBULE 201 TO VAV-3-24 VESTIBULE 201 VESTIBULE 201 VESTIBULE 201 M204 MATCH LINE P TO PDU-2 10 P11 TO PDU-2 12 $PL 13 P 15 TO PDU-1A P 14 TO PDU-1A 16 $PL 17 HWR HWS 3/4"3/4" TO CF-3 $ TO CF-4A $ TO CF-5A $ CO2 CO2 CO2 CO2 CO2 18 18 18 18 18 TO EF-1 T TO EF-2 P OS TO EF-3 TO EF-5 T 2 1/2" TO MAU-1 T 1"1" MAIN LEVEL HVAC PIPING PLAN KEYNOTES: (NOTE: NOT ALL KEYNOTES APPLY TO EACH SHEET) VARIABLE AIR VOLUME TERMINAL UNIT WITH HYDRONIC HEATING COIL, TYPICAL. HATCHED AREA REPRESENTS UNIT'S CLEARANCE REQUIREMENTS. REFER TO DETAIL ON SHEET M501. REFER TO SCHEDULE ON SHEET M701. 1 HYDRONIC UNIT HEATER MOUNTED FROM STRUCTURE ABOVE, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 2 HYDRONIC CABINET UNIT HEATER, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 3 DUCTLESS SPLIT SYSTEM INDOOR UNIT, AS INDICATED. REFER TO SHEET M105 FOR CONDENSING UNIT LOCATION. REFER TO SCHEDULE ON SHEET M702. 4 PIPING OF SIZE INDICATED DOWN TO LOWER LEVEL.5 REFRIGERANT SUCTION AND REFRIGERANT LIQUID PIPING UP THROUGH ROOF. REFER TO SHEET M105 FOR CONTINUATION. 6 TEMPERATURE SENSOR MOUNTED ON WALL IN ELEVATOR SHAFT APPROXIMATELY 1'-0" BELOW ROOF DECK, AS INDICATED. ENSURE MOUNTING LOCATION DOES NOT INTERFERE WITH ELEVATOR OPERATION. 7 CONNECT TO EXISTING HEATING WATER SUPPLY AND RETURN PIPING. COORDINATE EXISTING HEATING WATER SYSTEM SHUTDOWN WITH OWNER OR PROVIDE HOT TAPS. 8 ADJACENT SPACE PRESSURE SENSOR. SET FLUSH WITH CEILING. T.C.C. TO SET SENSOR AND ROUTE TUBING TO PDU-2. NATATORIUM PRESSURE SENSOR, AS INDICATED. SET ON WALL AS HIGH AS POSSIBLE, APPROXIMATELY 22'-0". T.C.C. SHALL SET SENSOR AND ROUTE TUBING TO PDU-2. 11 PDU-2 REMOTE USER TERMINAL, AS INDICATED.12 PDU-2 PUSH BUTTON PURGE MODE SWITCH WITH PILOT LIGHT, BY T.C.C.13 CONNECT TO EXISTING HEATING WATER SUPPLY AND RETURN PIPING. COORDINATE EXISTING HEATING WATER SYSTEM SHUTDOWN WITH OWNER OR PROVIDE HOT TAPS. 9 10 ADD ALTERNATE #2 - ADJACENT SPACE PRESSURE SENSOR. SET FLUSH WITH CEILING. T.C.C. TO SET SENSOR AND ROUTE TUBING TO PDU-1A. 14 ADD ALTERNATE #2 - NATATORIUM PRESSURE SENSOR, AS INDICATED. SET ON WALL AS HIGH AS POSSIBLE, APPROXIMATELY 20'-0". T.C.C. SHALL SET SENSOR AND ROUTE TUBING TO PDU-1A. 15 ADD ALTERNATE #2 - PDU-1A PUSH BUTTON PURGE MODE SWITCH WITH PILOT LIGHT, BY T.C.C.17 ADD ALTERNATE #2 - PDU-1A REMOTE USER TERMINAL, AS INDICATED.16 IN EVENT THAT C02 SENSOR IS NOT INTEGRAL TO TEMPERATURE SENSOR, CO2 SENSOR SHALL BE INSTALLED 2" ABOVE TEMPERATURE SENSOR TO PREVENT CO2 SENSOR HEAT FROM AFFECTING TEMPERATURE READING. 18 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 1 9 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 MAIN LEVEL HVAC PIPING PLAN - SOUTH M204 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL HVAC PIPING PLAN - SOUTH T ectonic Cop yright 2007 T ectonic Cop yright 2007 UPPER LEVEL 0' - 0" GYM FLOOR -16' - 9" GYM ROOF 21' - 0" A B C D E F GA.1 B.7 H J CF-2CF-1 38"ø SA32"ø SA 40"ø RA 40x40 SA 40x40 SA 24"ø SA 18x12 SR-2 845 CFM 18x12 SR-2 845 CFM 24"ø SA 18x12 SR-2 845 CFM 18x12 SR-2 845 CFM RTU-1 MP GROUP EX 124 M/P GROUP EX 262 GYM 131 GYM STORAGE 132 18"ø SA 10x4 SG- 175 CFM UPPER LEVEL 0' - 0" TOP EX 12' - 4" E10 E11 EXISTING FFE 0' - 0" EF-4 4"ø CA 4"ø CA 4"ø CA CP-3CP-2 CP-1 B-2 B-3B-1 16x16 EG-1 500 CFM 16x16 EA P-2 P-1 ET-1 AS-1 4"ø FLUE 4"ø FLUE 4"ø FLUE 2"2" 2"2"2 1/2" 2 1/2"2 1/2" 2 1/2"2 1/2" 3/4" MECHANICAL A102 2 1/2" FOYER A101 M. LOCKERS 2 A103 2"UPPER LEVEL 0' - 0" TOP EX 12' - 4" EGEh EXISTING FFE 0' - 0" LOCKER ROOF 15' - 0" NJ EXIST POOL MECH A112 GUARD CHG 257 12x32 CA (E)12x32 CA 3' - 0" UPPER LEVEL 0' - 0" LOWER LEVEL -15' - 0" REC ROOF 2' - 0" AB ADAC 26x18 SA VAV-3-19 18x18 SA 10"ø SA 10"ø CD-1 235 CFM 30x24 TA OPENING 10"ø SD-1 235 CFM 10"ø SD-1 235 CFM 10"ø SD-1 235 CFM 12x14 SA 18x18 SA LOUNGE 102 COMMUNITY 141 UPPER LEVEL 0' - 0" TOP EX 12' - 4" Eh EXISTING FFE 0' - 0" LOCKER ROOF 15' - 0" NJ ET-1 3/4" AS-1 P-1 P-2 WATER HEATER RE: PLUMBING PLANS 16x16 EG-1 500 CFM EF-4 4"ø CA 4"ø FLUE HWR HW S 2 1/2" 2 1/2" 2 1/2" 2 1/2" 16x16 EA W. LOCKERS 221 MECHANICAL A102 M. LOCKERS 2 A103 UPPER LEVEL 0' - 0" TOP EX 12' - 4" T.O.S 22' - 6" EXISTING FFE 0' - 0" L 70x36 TG-114x14 SA VAV-3-7 8"ø SA 24"ø SA LOBBY 202 14x14 SA 24"ø SA TOP EX 12' - 4" EGEh EXISTING FFE 0' - 0" LOCKER ROOF 15' - 0" NJ FIRE DAMPER FIRE DAMPER 14x16 EA 12x12 SA18x14 SA 6"ø SA 6x20 EA 10"ø EA 10"ø EA 6x20 EA 10"ø EA 10"ø EA The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/4" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 3 0 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC SECTIONS M301 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/4" = 1'-0"M301 1 GYMNASIUM HVAC SECTION SCALE: 1/4" = 1'-0"M301 2 MECHANICAL ROOM HVAC SECTION I SCALE: 1/4" = 1'-0"M301 3 (E)POOL MECHANICAL ROOM HVAC SECTION SCALE: 1/4" = 1'-0"M301 4 COMMUNITY ROOM HVAC SECTION SCALE: 1/4" = 1'-0"M301 5 MECHANICAL ROOM HVAC SECTION II SCALE: 1/4" = 1'-0"M301 6 TRACK/CARDIO TRANSFER AIR SECTION SCALE: 1/4" = 1'-0"M301 7 EF-6 EXHAUST AIR DUCTWORK SECTION T ectonic Cop yright 2007 T ectonic Cop yright 2007 T ectonic Cop yright 2007 T ectonic Cop yright 2007T ectonic Cop yright 2007T ectonic Cop yright 2007T ectonic Cop yright 2007T ectonic Cop yright 2007T ectonic Cop yright 2007 UPPER LEVEL 0' - 0" POOL ROOF 24' - 0" TOP EX 12' - 4" T.O.S 22' - 6" E12E13 EXISTING FFE 0' - 0" 2 M302 72x104 LVR-1 17,200 CFM 32"ø SA 18x72 RA 18x72 RA 56x68 RA 52x72 RA 52x72 RA POOL ROOF 24' - 0" TOP EX 12' - 4" T.O.S 22' - 6" EBECEDEEEF EXISTING FFE 0' - 0" (E)56x36 RA (E)32"ø SA (2)72x18 RA SHALL REPLACE EXISTING DUCTWORK EXISTING DUCTWORK ELBOW TO REMAIN 72x104 LVR-1 17,200 CFM 32"ø SA (E)44"ø SA 12"ø SA 8"ø SA 8"ø SA EXIST POOL DECK A109 STORAGE A105 (E)48" DEEP GLUELAM (E)22" DEEP JOISTS BEYOND WALL. MANUAL VOLUME DAMPER NEW ALUMINUM DUCTWORK. PAINT TO MATCH EXISTING. PENETRATE WALL AT MID POINT OF JOISTS BEYOND (APPROXIMATEL 10'-0" AFF) 0' - 8 " UPPER LEVEL 0' - 0" POOL ROOF 24' - 0" T.O.S 22' - 6" 676.4 EXISTING FFE 0' - 0" LOCKER ROOF 15' - 0" 8 7.9 5 42"ø SA 18x44 RA 52x24 RA 64x72 LVR-2 9,570 CFM 64x72 LVR-3 9,570 CFM ACTIVITY POOL 001W. LOCKERS 221 FAM CHANGING 212 ACR1 213 ALT WATER SLIDE 002 PDU-2 24x52 RA 24x52 RA 18x44 RARETURN AIR PLENUM BOX CF-3 24x10 SR-1 980 CFM 24x10 SR-1 980 CFM 40x32 EA 24x10 SR-1 980 CFM 40x40 SA 36"ø SA 24x52 RA 18x44 RA The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/4" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 3 6 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC SECTIONS M302 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/4" = 1'-0"M302 1 PDU-1A RETURN AIR DUCTWORK SECTION SCALE: 1/4" = 1'-0"M302 2 (E)NATATORIUM RETURN AIR DUCTWORK SECTION SCALE: 1/4" = 1'-0"M302 3 PDU-2 DUCTWORK SECTION E10 E11 Eh P-24 P-14 2ET-1 B-31B-21B-11 CP-3 3AS-1 MECHANICAL A102 EPO CP-2CP-1 16x16 EA 9 8 16x16 EG-1 500 CFM 10 10 10 HWS 2" 2" 2" 2" 2 1/2" 2 1/2" 5 4"ø 6 4"ø7 4"ø 6 4"ø6 4"ø7 4"ø 7 4"ø 6 4"ø 6 4"ø7 4"ø7 4"ø 6 4"ø 7 2 1/2" HWR 2 1/2" 2 1/2" 2 M301 2 1/2"2 1/2" 5 M301 TO EF-4 T B 12 ENLARGED SCALE MECHANICAL ROOM PLAN KEYNOTES: WALL HUNG CONDENSING BOILER WITH ASSOCIATED CIRCULATION PUMP BELOW. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. HYDRONIC EXPANSION TANK SET ON 4" CONCRETE HOUSEKEEPING PAD. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 1 HYDRAULIC/AIR/DIRT SEPARATOR SUPPORTED FROM STRUCTURE ABOVE. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. INLINE SYSTEM PUMPS STACKED ONE ABOVE THE OTHER AND RACKED ON WALL. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. DDC FRONT END CONTROL PANEL, AS INDICATED. CPVC FLUE THROUGH ROOF OF SIZE INDICATED. REFER TO SHEET M105 FOR CONTINUATION. SLOPE FLUE BACK TO BOILER AT 1/4" PER FOOT. PVC COMBUSTION AIR DUCTWORK THROUGH ROOF OF SIZE INDICATED. REFER TO SHEET M105 FOR CONTINUATION. BOILER ROOM EPO SWITCH BY T.C.C., AS INDICATED. EXHAUST DUCTWORK OF SIZE INDICATED UP THROUGH ROOF TO EXHAUST FAN ABOVE. TRANSITION TO UNIT OPENING SIZE. PROVIDE FLEXIBLE CONNECTION. REFER TO SHEET M105 FOR CONTINUATION. GAS FIRED WATER HEATER BY DIVISION 22 SHOWN FOR COORDINATION PURPOSES ONLY. PROVIDE VENTING SYSTEM AS INDICATED. REFER TO PLUMBING DRAWINGS FOR REQUIREMENTS. 2 3 4 5 6 7 8 9 10 HEATING WATER CIRCULATION PUMP, AS INDICATED. REFER TO DETAIL ON SHEET M502. REFER TO SCHEDULE ON SHEET M702. 11 BACKDRAFT DAMPER IN DUCTWORK OF SIZE AND TYPE INDICATED IMMEDIATELY BELOW ROOF DECK.12 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/2" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 3 9 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 ENLARGED MECHANICAL ROOM HVAC PLAN M401 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/2" = 1'-0" ENLARGED SCALE MECHANICAL ROOM PLAN 7 M501 6 M501 8 M501 M501 53 M501 4 M501 14 M501 2 M501 10 M501 12 M501 13 M501 15 M501 M501 1 11 M501 M501 9 16 M501 17 M501 18 M501 19 M501 CEILING DIFFUSER DETAILBRANCH DUCT TAKE-OFF DETAIL DUCT STRAP HANGER DETAIL EXPOSED DUCT SUPPLY REGISTER DETAILEXPOSED ROUND DUCT SUPPORT EXPOSED ROUND DUCT SUPPORT ROOF EXHAUST FAN DETAIL EXPOSED ROUND DUCT SUPPORT INSTALLATION DETAIL-VAV TERMINAL UNIT RETURN AIR GRILLE WITH SOUND BOOT CEILING EXHAUST FAN FIRE DAMPER DETAIL GOOSENECK DETAIL RTU DUCT THROUGH ROOF DETAIL EXPOSED DUCT CURVED SUPPLY GRILLE DETAIL FLUE THRU ROOF DETAIL COMBUSTION AIR ROOF TERMINATION DETAIL ROOF EXHAUST FAN ADAPTER CURB DETAIL L W 45° L=1/4 W (4" MIN.) NOTE: 60" 48" 36" 8'-0" 8'-0" 8'-0" 8'-0"1-1/2" x 1-1/2" x 1/8"1/4" ROUND ROD 2" x 2" x 1/8" 2" x 2" x 1/8" 2" x 2" x 1/8" 5/16" ROUND ROD 1" HANGER STRAPS NO POP RIVETS ALLOWED TOP CORD OF TRUSS 1/4"ø x 1-1/4" HEX HEAD LAG BOLT HANGER SIZES FOR RECTANGULAR DUCT MAX. SIZE HANGER HORIZONTAL SUPPORT ANGLE MAXIMUM SPACING 30" 1" x 18" GAGE STRAP SELF TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW STRAPS TO BE TIGHT AGANIST THE DUCT. NONE REQUIRED 10'-0" 84" 1/4" ROUND ROD ROUND SUPPLY AIR DUCT (TYP.) DIAMETER VARIES, REFER TO PLANS FOR DIMENSION ANGLE AS SHOWN ON PLANS GASKET DRUM PIVOT POINT SPIRAL DUCT MOUNTED DRUM LOUVER DAMPER/ EXTRACTOR EXPOSED SPIRAL ROUND DUCT LOAD RATED FASTENER THREADED ADAPTER PLATE; EYE-END ON ALL-THREAD; OR EQUIVALENT CONNECTOR. ALL-THREAD ROD SIZED PER SMACNA STANDARDS DUCT STRAP SIZED PER SMACNA STANDARDS EXPOSED SPIRAL ROUND DUCT LOAD RATED FASTENER ALL-THREAD ROD SIZED PER SMACNA STANDARDS (TYP.). ANGLE ATTACHMENT DUCT STRAP SIZED PER SMACNA STANDARDS. TOP APPLICABLE SMACNA STANDARDS. 1. SUPPORT SHALL COMPLY WITH ALL NOTE: OF DUCT RUNS FOR ALL DIAMETERS. 2. THIS DETAIL APPLIES TO THE END SHALL BE PROVIDED IN A NEAT AND 3. HANGER ATTACHMENT TO STRUCTURE WORKMAN LIKE MANNER AND SHALL BE COORDINATED WITH THE G.C. FOR APPROVAL. TO PREVENT DUCT MOVEMENT. DUCT MATERIAL. 4. HANGER MATERIALS SHALL MATCH APPLICABLE SMACNA STANDARDS. 1. SUPPORT SHALL COMPLY WITH ALL NOTE: DIAMETERS OF 36" OR LESS. 2. THIS DETAIL APPLIES TO DUCT SHALL BE PROVIDED IN A NEAT AND 3. HANGER ATTACHMENT TO STRUCTURE WORKMAN LIKE MANNER AND SHALL BE COORDINATED WITH THE G.C. FOR APPROVAL. THE DUCT MATERIAL. 4. HANGER MATERIALS SHALL MATCH STRAP IS REQUIRED. ALL-THREAD HANGER.ALL-THREAD HANGER. BEND RADIUS = 1 x DIAMETER OF THE FLEX DUCT, MINIMUM. CEILING DIFFUSER SEE PLANS FOR SIZE AND TYPE. PROVIDE STAINLESS STEEL BRIDGE CLAMP, OR SIMILAR, AROUND INNER HELIX AT THE CONNECTION TO THE DIFFUSER NECK. TAPE INSULATION TO DIFFUSER NECK IN A NEAT, WORKMAN LIKE MANNER. SOUND ATTENUATING FLEXIBLE DUCT. SEE PLANS FOR SIZE. HANGER STRAP TO SUPPORT REQUIRED BEND RADIUS. CEILING ROUTE POWER SUPPLY IN CORNER INSIDE CURB DAMPER BY FAN ROOF CURB AND FULL LENGTH OF PROVIDE NEOPRENE PAD, PERIMETER BETWEEN MANUFACTURER SWITCH UNDER FAN SAFETY DISCONNECT ROOF CURB; ARCH. DWGS. FOR DETAIL ALUMINUM CANVAS PLANS FOR TYPE EXHAUST DUCTWORK. ROOF DECK, REFER TO FAN. REFER CENTRIFUGAL ROOF EXHAUST CURB CAP REFER TO TO SCHEDULE. OF FLASHING. ARCH. DWGS. FLEXIBLE CONNECTION REFER TO SIZES. ROOF CURB SHALL BE MIN. 18" HIGH. COVER BY DIVISION 26 CURB CAP. EXPOSED SPIRAL ROUND DUCT LOAD RATED FASTENER (TYP.). ALL-THREAD HANGER CONNECTED TO STRUCTURE ABOVE. (TYP.) ALL-THREAD ROD SIZED PER SMACNA STANDARDS (TYP.). DUCT STRAP SIZED PER SMACNA STANDARDS. TOP APPLICABLE SMACNA STANDARDS. 1. SUPPORT SHALL COMPLY WITH ALL NOTE: DIAMETERS OF 38" OR GREATER. 2. THIS DETAIL APPLIES TO DUCT SHALL BE PROVIDED IN A NEAT AND 3. HANGER ATTACHMENT TO STRUCTURE WORKMAN LIKE MANNER AND SHALL BE COORDINATED WITH THE G.C. FOR APPROVAL. THE DUCT MATERIAL. 4. HANGER MATERIALS SHALL MATCH STRAP SHALL BE A CONTRACTOR'S OPTION. 3/8" ROUND ROD ON SIDE OF UNIT AS INDICATED ON DRAWINGS. CONTROLLER FOR SERVICE AND ACCESS PROVIDE 24" CLEARANCE IN FRONT OF UNIT MANUFACTURER. MOUNT CONTROLLER CONTROLLER PROVIDED BY CONTROLS MANUFACTURER, MOUNTED BY TERMINAL MAINTAIN 4.0 DIAMETERS OR 30" OF STRAIGHT SHEET METAL DUCT AS INDICATED ON DRAWINGS. AT UNIT INLET PROVIDE CONICAL TAKE OFF FITTING TO VAV INLET SU P P L Y A I R DU C T M A I N HW R HW S HOT WATER HEATING COIL BY UNIT FOR CAPACITY AND FLOOR PLANS MANUFACTURER, REFER TO SCHEDULE FOR LOCATIONS. FLOOR PLANS FOR SIZE DISCHARGE DUCT, REFER TO (APPLICABLE AT TERMINALS WITH TRANSITION IS REQUIRED FOR MIN. 10"x10" ACCESS DOOR DISCHARGE DUCT HEATING COILS) SUPPORT FROM STRUCTURE WITH AIR TERMINAL UNIT, REFER TO 1-1/4" HANGER STRAP SCHEDULE FOR CAPACITIES RETURN PIPING, REFER TO PIPING HOT WATER HEATING SUPPLY AND DETAIL AND FLOOR PLANS FOR LOCATIONS RETURN AIR GRILLE. REFER 1" RIGID FIBERGLASS 18" MIN. DUCT BOARD TO SCHEDULE. 6"x9" GASKETED ACCESS DOOR WITH QUARTER TURN FASTENERS PROVIDED WITH TERMINAL UNIT BACKDRAFT DAMPER EXHAUST FAN STRUCTURE SUPPORT FROM FLANGE CEILING INTEGRAL GRILLE ADJUSTABLE RUBBER GROMMET DISCHARGE DUCT FLEX CONNECTION ASSEMBLY 90° AND PROVIDE WITH SPRING NEGATOR EXTENSION. VERTICAL TYPE FIRE DAMPER SHOWN. FOR HORIZONTAL TYPE TURN NOTE: LOCAL CODE GAUGE PER STEEL SHEET ACCESS DOOR TYPE "B" DAMPER SLEEVE. BOTH SIDES OF BREAKWAY JOINT, INSTRUCTIONS. ACCORDANCE WITH MFR. MAINTAIN CLEARANCE IN WALL. AROUND BOTH SIDES OF RETAINING ANGLES ALL 1-1/2"x1-1/2"x1/8" FIRE DAMPER COUNTERFLASHING SEE ARCHITECTURAL 6" MINIMUM OVERLAP DUCTWORK DIMENSIONS RE: MECHANICAL DRAWINGS FOR 36 " M I N DWGS. FOR CURB BIRDSCREEN (BY M.C.) 45° FLASHING (BY M.C.) (BY M.C.) WATERTIGHT SCREWS & CAULK WITH SHEETMETAL FLASHING TO DUCT SECURE COUNTER WATERTIGHT CAULK JOINTS DETAIL REFER TO PLAN FOR DUCT SIZE REFER TO STRUCTURAL DRAWINGS FOR SIZES AND LOCATIONS OF STRUCTURAL MEMBERS 6" EXTEND 6" CONCRETE PAD DIRECTIONS. CANT STRIP, BY G.C. 2" RIGID INSULATION, BY G.C. ROOFTOP UNIT DUCTWORK CONNECTION TO FULL SIZE OPENING TRANSITION TO DUCT SIZES SHOWN ON PLANS ROOF OPENING SHALL BE 1" LARGER THAN DUCTWORK - CAULK OPENING ALL AROUND ROOF INSULATION ROOF MEMBRANE, BY G.C. REFER TO STRUCTURAL PLANS. FLEXIBLE DUCT CONNECTOR OF RTU 6" BEYOND RTU IN ALL ROUND SUPPLY AIR DUCT (TYP.) DIAMETER VARIES, REFER TO PLANS FOR DIMENSION ANGLE AS SHOWN ON PLANS GASKET SPIRAL DUCT MOUNTED SUPPLY REGISTER MANUAL VOLUME DAMPER/ AIR EXTRACTOR (SR-6 ONLY) BRIEDERT TYPE DISCHARGE CAP TYPE "B" FLUE MASTIC OR CAULKING COMPOUND FLASHING COLLAR (TYPICAL OF ALL SEALS) THIMBLE STORM COLLAR ROOF TYPE "B" FLUE MAINTAIN MIN. 1" CLEARANCE TO ALL COMBUSTIBLE CONSTRUCTION. FLASH AND COUNTERFLASH2' - 0 " A B O V E R O O F A N D 3 ' - 0 " M I N . AB O V E A N Y C O M B U S T I O N A I R IN T A K E W I T H I N 1 0 ' - 0 . " TO COMBUSTION PIPE WITH CAULK SECURE COUNTERFLASHING FLASHING (BY G.C.) ROOF 2"x12" CURB CANT STRIP (BY M.C.) (BY G.C.) OR APPROVED METHODS AND MAKE WATERTIGHT (BY M.C.) 36" PROVIDE CHICKEN WIRE AT EACH OPENING OF MITERED DUCT END. DO NOT PROVIDE 1/2" BIRD SCREEN AS THE 1/2" MESH SIZE CAN POTENTIALLY FREEZE AND SHUT BOILER SYSTEM DOWN ON LACK OF COMBUSTION AIR. TEE FITTING WITH 45° MITERED DUCT ENDS. TEE ALLOWS WIND TO PASS THROUGH FITTING WITHOUT INFLUENCING PRESSURE OR INTRODUCING FREEZING AIR INTO THE COMBUSTION SYSTEM. COMBUSTION AIR DUCT. CONFIRM SIZE AND TYPE WITH MAKE-UP AIR UNIT MANUFACTURER. REFER TO PLAN VIEW FOR DETAILS. UV RESISTANT SUPPORT BASE. UNISTRUT OR SIMILAR ADJUSTABLE SUPPORT LEGS. 18 " M I N I M U M LAYERED RIGID FOAM INSULATION TO FORM SLOPED TOP. DUCTWORK. REFER TO DRAWINGS FOR SIZE. REFER TO SPECIFICATION FOR MATERIAL AND LINER REQUIREMENTS. MINIMUM R-8 RIGID FIBERGLASS INSULATION. ADJUSTABLE BASE RAIL SECURED TO LEGS WITH FOUR POINTS OF CONNECTION ALUMINUM WEATHER RESISTANT JACKETING. MIN. 0.016" THICK SMOOTH OR EMBOSSED FINISH PER THE SPECIFICATION. EXISTING FAN. REFER CENTRIFUGAL ROOF EXHAUST ROOF CURB. TO SCHEDULE. NEW ALUMINUM ADAPTER CURB. NOTE: REFER TO 'ROOF EXHAUST FAN DETAIL' FOR FURTHER REQUIREMENTS. SWITCH UNDER FAN SAFETY DISCONNECT COVER BY FAN MFR. ALUMINUM CURB CAP. CONNECT TO EXISTING ELECTRICAL WIRING SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONESCALE: NONE NO SCALE SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE (SR-2 )(END OF DUCT RUN)(EXPOSED SPIRAL DUCT - 36"ø OR LESS)(EXPOSED SPIRAL DUCT - 38"ø OR GREATER) SCALE: NONE NO SCALE NO SCALE SCALE: NONE SCALE: NONE SCALE: NONE (SR-6 ) SCALE: NONE SCALE: NONE ROOF MOUNTED DUCT AND SUPPORT DETAIL ROOF The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 4 0 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC DETAILS M501 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: NONE 1 M502 7 M502 9 M502 10 M502 11 M502 2 M502 3 M502 4 M502 8 M502 6 M502 6 M502 12 M502 CONDENSATE DRAIN TRAP EXPANSION TANK AND AIR/DIRT/HYDRAULIC SEPARATOR PIPING DETAIL CABINET UNIT HEATER PIPING DETAIL UNIT HEATER-HOT WATER STRAINER 3-WAY HEATING COIL PIPING DETAIL 2-WAY HEATING COIL PIPING DETAIL IN-LINE PUMP DETAIL WALL HUNG CONDENSING BOILER CABINET UNIT HEATER PIPING DETAILCHEMICAL POT FEEDER DETAIL TYPICAL PIPE HANGER DETAIL FIRE/SMOKE DAMPER INSTALLATION DETAIL 1. H=SUPPLY FAN TOTAL STATIC PRESSURE IN INCHES. NOTES: CAP FLOW H/2 3. TRAPS SHALL BE INSULATED AND PROVIDED WITH HEAT TRACE. H TYP. 2. LOCATE TRAPS TO BE ACCESSIBLE FOR CLEANING. CAP FLOW H H/2 TYP. *POSITIVE PRESSURE TRAP (COOLING COIL) *NEGATIVE PRESSURE TRAP (HEAT EXCHANGER ) PIPE FULL SIZE TO PDU PIPE FULL SIZE TO PDU AIR SEPARATOR DRAIN BOTTOM OF SYSTEM MAIN PIPE EXPANSION LINE OFF AIR/DIRT/HYDRAULIC SEPARATOR OR UNION (TYP.) FLANGED CONNECTION STRUCTURE NEAREST FLOOR DRAIN EXTEND FULL SIZE TO SUPPORT FROM HWS HANGER/SUPPORT ROD (TYP.) PRESSURE GAUGE WITH FLOOR DRAIN FULL SIZE TO PIPE AIR VENT BALL VALVE (TYP.) BALL VALVE (TYP.) HWR MANUAL AIR VENT TO FLOOR DRAIN. AIR VENT. PIPE FULL SIZE REFER TO SCHEDULE FOR PRESSURIZED BLADDER TYPE EXPANSION TANK SIZE (TYP.) AND QUANTITY. FLOOR AIR CHARGING VALVE (TYP.) VALVE WITH BALL DRAIN HOUSEKEEPING PAD 4" CONCRETE SHUT OFF VALVE. REFER TO NOTE 2 BELOW. NOTES: 1. RE: SPECIFICATIONS FOR TYPE OF VALVE (BALL OR BUTTERFLY) BASED ON PIPE SIZE. HOSE END FITTING (TYP.) HWR TO BOILER INLET FROM BOILER DISCHARGE SYSTEM SUPPLY, HWS SYSTEM RETURN HWS NOTE: WHERE POSSIBLE, KEEP VALVES WITHIN CABINET ENCLOSURE. CONTROL VALVE TWO-WAY AUTOMATIC TEMPERATURE HEATING COIL MANUAL AIR VENT METER FITTING AND VENTURI TYPE FLOW UNION (TYP.) P & T TEST PLUG (TYP.) HW R N.O. HWR MAIN HWS MAIN BALL VALVE (TYP.) STRAINER CABINET UNIT HEATER END (TYP.) DRAIN VALVE WITH HOSE BALANCING VALVE WITH ALL-THREAD ROD. P&T TEST PLUG (TYP.) UNION (TYP.) MANUAL AIR VENT SUPPORT FROM STRUCTURE UNIT HEATER REFER TO DRAIN VALVE WITH HOSE END, CAP AND CHAIN HWR BALL VALVE VENTURI TYPE FLOW MAIN HWS SCHEDULE METER FITTING (TYP.) HWR MAIN HWS P & T TEST PLUG (TYP.) CONTROL VALVE 3-WAY TEMPERATURE HEATING COIL MANUAL AIR VENT VENTURI TYPE FLOW METER COMBINATION BALANCING/ SHUT-OFF VALVE AND HWR STRAINER BALL VALVE (TYP.) HWS N.O. UNION (TYP.) FITTING END, CAP AND CHAIN DRAIN VALVE WITH HOSE C. N.C. FOR END OF RUN HEATING BY-PASS LEG BALANCE VALVE. DEVICES, BALANCE TO 50% OF COIL FLOW UNLESS P & T TEST PLUG (TYP.) CONTROL VALVE 2-WAY TEMPERATURE HEATING COIL MANUAL AIR VENT VENTURI TYPE FLOW METER COMBINATION BALANCING/ SHUT-OFF VALVE AND HWR STRAINER BALL VALVE (TYP.) HWS N.O. UNION (TYP.) FITTING END, CAP AND CHAIN DRAIN VALVE WITH HOSE PRESSURE GAUGE FULL SIZE OF P&T (TYP.) CHECK VALVE PRESSURE GAUGE BALANCE VALVE WITH INLINE PUMP. REFER NOTES: 1. ON BOTH SIDES OF PUMP, INSTALL PIPE HANGER. 2. PROVIDE UNIONS ON BOTH SIDES OF PUMP WHERE MANUFACTURER DOES NOT PROVIDE FLANGE. AND SPEC. (TYP.) BALL VALVE PER SIZE BUTTERFLY VALVE OR STRAINER WITH HOSE END DRAIN TO SCHEDULE FOR SIZE AND CAPACITIES. PIPE HANGER, REFER TO SPEC. (TYP.) SEE PLANS & SERVICES FOR PIPE SIZES FLOW METER FITTING, REFER TO SPEC. REQUIRED (TYP.) ECCENTIC REDUCER/ INCREASER AS 3. INSTALL WITH MOTOR IN PROPER POSITION PER MANUFACTURER'S REQUIREMENTS. NOTE: RECESSED WALL TYPE WITH INTEGRAL THERMOSTAT, NOTE: DETAIL APPLIES TO BOTH NEW AND EXISTING UNIT HEATERS. INDICATED OTHERWISE. CEILING MOUNTED TYPE WITH WALL THERMSTAT. N.O. 2-WAY TEMPERATURE CONTROL VALVE FORCED DRAFT UNION, TYP. BALL SHUT OFF VALVE, TYP. BOILER DRAIN FULL SIZE TO FLOOR SINK THERMOMETER, TYP. PRESSURE RELIEF, PIPE FULL SIZE TO FLOOR SINK PVC BOILER COMBUSTION AIR REFER TO PLANS FOR SIZES PVC BOILER FLUE REFER TO PLAN FOR SIZES HWS HWR REFER TO PLAN FOR SIZES, TYP. CONDENSING BOILER (WALL HUNG) FLANGED CONNECTION, TYP. NEUTRALIZATION KIT DRAIN LINE TO NEAREST FLOOR DRAN.NEUTRALIZATION KIT BY BOILER MANUFACTURER. FLEX/PVC CONDENSATE PIPE TO NEUTRALIZATION KIT. HWS CONTROL VALVE THREE-WAY AUTOMATIC TEMPERATURE HEATING COIL MANUAL AIR VENT METER FITTING AND VENTURI TYPE FLOW UNION (TYP.) P & T TEST PLUG (TYP.) HW R HWR MAIN HWS MAIN BALL VALVE (TYP.) STRAINER CABINET UNIT HEATER END (TYP.) DRAIN VALVE WITH HOSE BALANCING VALVE N.O. C. N.C. UNLESS INDICATED OTHERWISE. DEVICES, BALANCE TO FULL FLOW, BY-PASS LEG BALANCE VALVE. FOR END OF RUN HEATING (REFER TO PLUMBING DRAWINGS 1" SYSTEM MAKE UP (DCW) FOR CONTINUATION) TO PUMP SUCTION HIGH CAPACITY AUTOMATIC PUMP DISCHARGE 3/4" 3/4" HOSE END DRAIN VALVE (TYP.) HEADER 5 GAL. CAP. 4" CONCRETE TOP FEED MOUNT FEEDER ON CONCRETE PAD OR RIGIDLY MOUNT TO MECHANICAL ROOM WITH WIDE MOUTH PAD WALL. BALL VALVE (TYP.) CHECK VALVE UNION (TYP.) 3/4" SYSTEM PUMPS SHOT FEEDER, REFER TO PLANS FOR SIZES. PUMP SUCTION HEADER. FOR CLAMP SPACING REFER TO SPECIFICATIONS SPECIFIED INSULATION AS (TYP.) TOP AND BOTTOM NUT AND WASHER STEEL ANGLE HANGER 1-1/2 X 1-1/2 X 1/4 SADDLE (TYP.) INSULATION PROTECTIVE PIPE INSULATION HANGER CLEVIS TYPE HANGER RODS 1/4"ø THREADED (TYP.) (TYP.) (TYP.) DUCTWORK AS INDICATED ON FLOOR PLANS MOUNTING FRAME & FASTENERS OF TYPE, SIZE, NUMBER & SPACING AS REQ'D BY MANUFACTURER NOTE: RUSKIN FSD60 COMBINATION FIRE/SMOKE DAMPER SHOWN. SIZES REFLECT USE OF THE RUSKIN BY SEPARATE CONTRACT. INDICATED PROVIDE SLEEVE LENGTH REQUIRED FOR 24" DAMPER SLEEVE DUCT FLANGE 1%%189" H, TYP BREAK-AWAY BY DIVISION 26. CONTROL PANEL ALARM FIRE MAINTAIN ACCESS FOOTPRINT BELOW DAMPER OPERATOR & ACCESS DOOR OF DAMPER OPERATION. PROVIDE AN FOR ANNUAL TESTING & VERIFICATION CONDUIT SHALL EXTEND BELOW SLEEVE. SLEEVE. NEITHER OPERATOR NOR OPERATOR ON EXTERIOR OF DAMPER DAMPERS LOCATED OVER A GYPSUM CEILING. 18"x18" CEILING ACCESS DOOR FOR ALL OF DAMPER ACCESS DOOR ON OPERATOR SIDE &/OR FIRE STAT SENSOR ONLY ARCHITECTURAL DRAWINGS FOR WALL TYPE. BLADE POSITION INDICATOR ON DAMPERS WHERE REQUIRED DAMPER BLADES & FRAME IN PLANE OF FIRE WALL RATED WALL. REFER TO TS150 FIRESTAT. THE TS150 FIRESTAT IS ONLY REQUIRED ON SYSTEMS UTILIZING A SMOKE CONTROL SYSTEM. EACH INSTALLATION SCALE: NONE SCALE: NONE SCALE: NONE (2-WAY VALVE) SCALE: NONE SCALE: NONE (TERMINAL UNITS) SCALE: NONE (TERMINAL UNITS)SCALE: NONE SCALE: NONE (3-WAY VALVE) SCALE: NONE SCALE: NONE SCALE: NONE The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 4 3 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC DETAILS M502 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: NONE SCALE: NONE SCALE: NONE SINGLE ZONE VAV PACKAGED ROOF TOP UNIT, RETURN FAN - CONTROL DIAGRAM (RTU-1) MULTIPLE ZONE VAV PACKAGED ROOF TOP UNIT, RETURN FAN - CONTROL DIAGRAM (RTU-2) MULTIPLE ZONE VAV PACKAGED ROOF TOP UNIT, RETURN FAN - CONTROL DIAGRAM (RTU-3) BLDG-SP - SPACE SENSOR ATMOSPHERIC SENSING HEAD LOCATE IN A LOW WIND AREA FURNISHED AND WIRED BY TCC FIELD INSTALLED BY TCC FIELD INSTALLED BY TCC SA TO ZONE HEAT PERCENTAGE COOLING PERCENTAGE BUILDING STATIC PRESSURE SUPPLY FAN SPEED DISCHARGE AIR HEATING SETPOINT DISCHARGE AIR COOLING SETPOINT RETURN FAN VFD SPEED ECONOMIZER MINIMUM POSITION UNIT STATUS RETURN FAN STATUS 2 4 3 1 ANALOG INPUT 3 2 1 INPUT DIGITAL RETURN FAN START/STOP 2 4 3 1 ANALOG OUTPUT 3 2 1 OUTPUT DIGITAL POINTS LIST UNIT ENABLE/DISABLE ALARM STATUS DUCT STATIC PRESSURE SETPOINT5ECONOMIZER DAMPER POSITION 5 OUTDOOR AIR TEMPERATURE 6 RETURN AIR TEMPERATURE 7 MIXED AIR TEMPERATURE 8 DISCHARGE AIR TEMPERATURE 9 10 4*RETURN AIR SMOKE DETECTOR* 11 *ZONE TEMPERATURE*12 *ZONE TEMPERATURE ACTIVE SETPOINT*13 6 SUPPLY FAN VFD SPEED7 8 *ZONE HUMIDITY*14 *ZONE HUMIDITY ACTIVE SETPOINT*15 HOT-GAS REHEAT PERCENTAGE 16 OUTSIDE AIR FLOW RATE 12 ZN-T-SET ZN-T 13 14 ZN-H-SET ZN-H 15 5SUPPLY FAN STATUS 4 SUPPLY FAN START/STOP DX STAGE 1 - VARIABLE SPEED COMPRESSOR9 6DX STAGE 2 STATUS 7DX STAGE 3 STATUS 5 DX STAGE 1 START/STOP 6 DX STAGE 2 START/STOP DX STAGE 3 START/STOP GAS HEAT MODULATION COILING COIL LEAVING AIR TEMPERATURE HOT-GAS REHEAT MODULATION RTU-1 LOCATION = GYMNASIUM 131 BUILDING STATIC PRESSURE SETPOINT10 HEAT PERCENTAGE COOLING PERCENTAGE BUILDING STATIC PRESSURE SUPPLY FAN SPEED DISCHARGE AIR HEATING SETPOINT DISCHARGE AIR COOLING SETPOINT RETURN FAN VFD ECONOMIZER MINIMUM POSITION UNIT STATUS RETURN FAN STATUS 2 4 3 1 ANALOG INPUT 3 2 1 INPUT DIGITAL RETURN FAN START/STOP 2 4 3 1 ANALOG OUTPUT 3 2 1 OUTPUT DIGITAL POINTS LIST UNIT ENABLE/DISABLE BUILDING STATIC PRESSURE SETPOINTALARM STATUS DUCT STATIC PRESSURE SETPOINT5ECONOMIZER DAMPER POSITION 5 OUTDOOR AIR TEMPERATURE 6 RETURN AIR TEMPERATURE 7 MIXED AIR TEMPERATURE 8 DISCHARGE AIR TEMPERATURE 9 *OUTSIDE AIR CO2*10 4*RETURN AIR SMOKE DETECTOR* 11 12 13 6 SUPPLY FAN VFD 7 8 DUCT STATIC PRESSURE OUTSIDE AIR FLOW RATE 5SUPPLY FAN STATUS 4 SUPPLY FAN START/STOP 6DX STAGE 2 7DUCT STATIC HIGH LIMIT 5 DX STAGE 1 START/STOP 6 DX STAGE 2 START/STOP GAS HEAT MODULATION COILING COIL LEAVING AIR TEMPERATURE DUCT STATIC PRESSURE SETPOINT BLDG-SP - SPACE SENSOR ATMOSPHERIC SENSING HEAD LOCATE IN A LOW WIND AREA FLOW FIELD INSTALLED BY TCC FIELD INSTALLED BY TCC MA-DPR (By E.C.) RA-SMK EA EA- DPR SA TO TERMINAL UNITS FILTERS C DX GAS-FIRED HEAT EXCHANGER 4 VFD VFD DIRECT EXPANSION COIL RO O F T O P U N I T I N T E G R A L CO N T R O L M O D U L E CO N D E N S I N G S E C T I O N OA RA MODULATION GAS HEAT - - - - -- STAGE 1 DX STAGE 2 DX - - -12 - OA-T - - OA-H - RA-H- RA-T- DA-T - POINTS INTERNAL TO FACTORY CONTROLLER (TYP.) HEAT PERCENTAGE COOLING PERCENTAGE BUILDING STATIC PRESSURE SUPPLY FAN SPEED DISCHARGE AIR HEATING SETPOINT DISCHARGE AIR COOLING SETPOINT RETURN FAN VFD ECONOMIZER MINIMUM POSITION UNIT STATUS RETURN FAN STATUS 2 4 3 1 ANALOG INPUT 3 2 1 INPUT DIGITAL RETURN FAN START/STOP 2 4 3 1 ANALOG OUTPUT 3 2 1 OUTPUT DIGITAL POINTS LIST UNIT ENABLE/DISABLE BUILDING STATIC PRESSURE SETPOINTALARM STATUS DUCT STATIC PRESSURE SETPOINT5ECONOMIZER DAMPER POSITION 5 OUTDOOR AIR TEMPERATURE 6 RETURN AIR TEMPERATURE 7 MIXED AIR TEMPERATURE 8 DISCHARGE AIR TEMPERATURE 9 *OUTSIDE AIR CO2*10 4*RETURN AIR SMOKE DETECTOR* 11 12 13 6 SUPPLY FAN VFD 7 8 DUCT STATIC PRESSURE OUTSIDE AIR FLOW RATE OA-CO2 10 POINTS AND SENSORS BY TCC, TYPICAL. 5SUPPLY FAN STATUS 4 SUPPLY FAN START/STOP STAGE 3 DX - -6DX STAGE 2 7DX STAGE 3 5 DX STAGE 1 START/STOP 6 DX STAGE 2 START/STOP 7 DX STAGE 3 START/STOP GAS HEAT MODULATION CC-LAT - COILING COIL LEAVING AIR TEMPERATURE SA-SP- DUCT STATIC SENSOR 2/3RDS DOWN THE DUCT (SEE PLANS FOR LOCATION) FIELD WIRED BY TCC DUCT STATIC PRESSURE SETPOINT RTU-3 LOCATION = LOUNGE 102OA FILTER S.P. @ 1.0" - COMMUNICATION LINE (BACnet MS/TP) FIELD INSTALLED BY TCC DS-HL - 8DUCT STATIC HIGH LIMIT DX STAGE 1 - VARIABLE SPEED COMPRESSOR9 - - DX STAGE 1 - VARIABLE SPEED COMPRESSOR9 - BLDG-SP - SPACE SENSOR ATMOSPHERIC SENSING HEAD LOCATE IN A LOW WIND AREA FLOW FIELD INSTALLED BY TCC FIELD INSTALLED BY TCC MA-DPR (By E.C.) RA-SMK EA EA- DPR SF SA TO TERMINAL UNITS FILTERS C DX GAS-FIRED HEAT EXCHANGER 4 VFD VFD DIRECT EXPANSION COIL RO O F T O P U N I T I N T E G R A L CO N T R O L M O D U L E CO N D E N S I N G S E C T I O N OA RA MODULATION GAS HEAT - - - - -- STAGE 1 DX STAGE 2 DX - - -12 - OA-T - - OA-H - RA-H- RA-T- RF DA-T - POINTS INTERNAL TO FACTORY CONTROLLER (TYP.) OA-CO2 10 POINTS AND SENSORS BY TCC, TYPICAL. CC-LAT - SA-SP- DUCT STATIC SENSOR 2/3RDS DOWN THE DUCT (SEE PLANS FOR LOCATION) FIELD WIRED BY TCC RTU-2 LOCATION = PARTY 211OA FILTER S.P. @ 1.0" - COMMUNICATION LINE (BACnet MS/TP) FIELD INSTALLED BY TCC DS-HL - - - - SF RF FLOW MA-DPR (By E.C.) RA-SMK EA EA- DPR SF FILTERS C DX GAS-FIRED HEAT EXCHANGER 4 VFD VFD DIRECT EXPANSION COIL RO O F T O P U N I T I N T E G R A L CO N T R O L M O D U L E CO N D E N S I N G S E C T I O N OA RA MODULATION GAS HEAT - - - - -- STAGE 1 DX STAGE 2 DX - - -12 - OA-T - - OA-H - RA-H- RA-T- RF DA-T - POINTS INTERNAL TO FACTORY CONTROLLER (TYP.) CC-LAT - OA FILTER S.P. @ 1.0" - COMMUNICATION LINE (BACnet MS/TP) FIELD INSTALLED BY TCC - -- MODULATION HOT GAS REHEAT- - STAGE 3 DX- - NOTES : 1. REFER TO SPECIFICATION SECTION 230923 FOR SEQUENCE OF OPERATION. 2. *POINTS WITH ASTERISKS ARE BY THE TEMPERATURE CONTROLS CONTRACTOR* 3. ALL OTHER POINTS ARE VIA THE FACTORY PROVIDED BACNET INTERFACE. TEMPERATURE CONTROLS CONTRACTOR SHALL MAP ALL POINTS AND DISPLAY THEM AT THE DDC SYSTEM'S FRONT END. NOTES : 1. REFER TO SPECIFICATION SECTION 230923 FOR SEQUENCE OF OPERATION. 2. *POINTS WITH ASTERISKS ARE BY THE TEMPERATURE CONTROLS CONTRACTOR* 3. ALL OTHER POINTS ARE VIA THE FACTORY PROVIDED BACNET INTERFACE. TEMPERATURE CONTROLS CONTRACTOR SHALL MAP ALL POINTS AND DISPLAY THEM AT THE DDC SYSTEM'S FRONT END. NOTES : 1. REFER TO SPECIFICATION SECTION 230923 FOR SEQUENCE OF OPERATION. 2. *POINTS WITH ASTERISKS ARE BY THE TEMPERATURE CONTROLS CONTRACTOR* 3. ALL OTHER POINTS ARE VIA THE FACTORY PROVIDED BACNET INTERFACE. TEMPERATURE CONTROLS CONTRACTOR SHALL MAP ALL POINTS AND DISPLAY THEM AT THE DDC SYSTEM'S FRONT END. HG RH The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 4 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC CONTROL DRAWINGS M601 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: NONE SCALE: NONE PACKAGED MAKE-UP AIR UNIT CONTROL SCHEMATIC (MAU-1) POOL DEHUMIDIFICATION UNIT CONTROL DIAGRAM (PDU-2) (PDU-1A - ADD ALTERNATE #2) OA-DPR DA-T SF SA GAS-FIRED HEAT EXCHANGER VFD OUTPUTINPUT ANALOGANALOG INPUT OUTPUT DIGITAL DIGITAL MAU STATUS *ZONE TEMPERATURE SETPOINT* OUTSIDE AIR TEMPERATURE DISCHARGE AIR TEMPERATURE MAU ENABLE / DISABLE 1 11 4 3 2 1 *ZONE TEMPERATURE* HEATING MODULATION POINTS LIST MA K E - U P A I R U N I T CO N T R O L M O D U L E OA (S.P.=80°F COOLING) (S.P.=60°F HEATING) DRAIN DCW COOLER DIRECT EVAPORATIVE EVAP PUMP 2SUPPLY FAN STATUS - ZN-T ZN-SET 3 4 - - MODULATION GAS HEAT - OA-T - FILTERS OA FILTER S.P. @ 1.0" - 2 SUPPLY FAN VFD % GAS HEAT ENABLE2 COOLING ENABLE3 - 3FILTER ALARM COMMUNICATION LINE (BACnet MS/TP) FIELD INSTALLED BY TCC FURNISHED AND WIRED BY TCC NOTES : 1. REFER TO SPECIFICATION SECTION 230923 FOR SEQUENCE OF OPERATION. 2. *POINTS WITH ASTERISKS ARE BY THE TEMPERATURE CONTROLS CONTRACTOR* 3. ALL OTHER POINTS ARE VIA THE FACTORY PROVIDED BACNET INTERFACE. TEMPERATURE CONTROLS CONTRACTOR SHALL MAP ALL POINTS AND DISPLAY THEM AT THE DDC SYSTEM'S FRONT END. EA SA SET BY TCC SEE DRAWINGS FOR LOCATION. BY TCC PD U F A C T O R Y M O U N T E D DD C C O N T R O L L E R LOCATE IN A LOW WIND AREA ATMOSPHERIC SENSING HEAD BLDG-SP OUTSIDE AIR TEMPERATURE MIXED AIR HUMIDITY MIXED AIR TEMPERATURE DISCHARGE AIR TEMPERATURE EXHAUST AIR TEMPERATURE NATATORIUM TO ATMOSPHERE DIFFERENTIAL PRESSURE SETPOINT NATATORIUM TO ADJACENT SPACE DIFFERENTIAL PRESSURE SETPOINT RETURN AIR TEMPERATURE SETPOINT RETURN AIR HUMIDITY SETPOINT EXHAUST FAN ALARM RETURN AIR SMOKE DETECTOR PDU STATUS 2 7 6 5 4 3 1 ANALOG INPUT 6 5 4 3 2 1 INPUT DIGITAL PDU START / STOP 2 4 3 1 ANALOG OUTPUT 2 1 OUTPUT DIGITAL POINTS LIST PURGE MODE ENABLE RETURN AIR TEMPERATURE RETURN AIR HUMIDITY SUPPLY FAN ARRAY ALARM OAB-DPR RA-H RA-T EA-T SF-1 MA-T MA-H DA-T11 10 9 MODULATING OUTSIDE AIR - IAQ DAMPER POSITION MINIMUM OUTSIDE AIR - IAQ DAMPER POSITION MODULATING OUTSIDE AIR - IAQ DAMPER AIRFLOW BLDG-SP 1. REFER TO SPECIFICATION SECTION 237301 FOR SEQUENCE OF OPERATION. 2. ALL POINTS LISTED SHALL BE DISPLAYED AT THE DDC SYSTEM'S FRONT END GUI. THE TEMPERATURE CONTROLS CONTRACTOR SHALL BE RESPONSIBLE FOR MAPPING ALL POINTS LISTED. 3. ALL POINTS ARE PULLED FROM THE UNITS FACTORY MOUNTED DDC CONTROLLER. 4. ANALOGUE AND DIGITAL OUTPUTS SHALL BE THE ONLY READ/WRITE POINTS. ALL OTHER POINTS ARE READ ONLY. 5. SPACE PRESSURE SENSORS SHALL BE PROVIDED BY THE PDU MANUFACTURER AND SHIPPED LOOSE FOR INSTALLATION BY THE TEMPERATURE CONTROLS CONTRACTOR. 6. TEMPERATURE CONTROLS CONTRACTOR SHALL INSTALL THE TUBING FROM THE SPACE PRESSURE SENSORS TO THE PRESSURE TRANSDUCERS SET WITHIN THE PDU. 3 VFD VFD OA-IAQ-DPR MINIMUM OA-IAQ-DPR MODULATING 12 MINIMUM OUTSIDE AIR - IAQ DAMPER AIRFLOW 13 OUTSIDE AIR BYPASS DAMPER POSITION RA-DPR 14 RETURN AIR DAMPER POSITION EA FILTER S.P. @ 1.0" OA FILTER S.P. @ 1.0" EA FILTER ALARM OA FILTER ALARM SF-2 OA OA-T OA 15 NATATORIUM TO ATMOSPHERE DIFFERENTIAL PRESSURE 16 NATATORIUM TO ADJACENT SPACE DIFFERENTIAL PRESSURE SEE PLANS FOR LOCATION. ADJACENT SPACE SENSOR SENSOR INSTALLED BY TCC SEE PLANS FOR LOCATION. NATATORIUM SENSOR SENSOR INSTALLED BY TCC 17 EXHAUST FAN SPEED 18SUPPLY FAN ARRAY SPEED EXHAUST FAN AIRFLOW 19 20 SUPPLY FAN #1 AIRFLOW SUPPLY FAN #2 AIRFLOW OCCUPIED / UNOCCUPIED MODE 8 WITH PILOT LIGHT FIELD INSTALLED BY TCC. PUSH BUTTON PURGE MODE ENABLE SEE DRAWINGS FOR LOCATION. H G GAS FIRED HEAT EXCHANGER RA RA-SMK SMOKE DETECTOR BY PDU MANUFACTURER. REMOTE USER TERMINAL 6 CONDUCTOR WIRE - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - EF-1 SF-2 AF SF-1 AF EF-1 AF COMMUNICATION LINE (BACnet MS/TP) - - - - - - The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 4 6 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC CONTROL DRAWINGS M602 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O T SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE HEATING WATER SYSTEM - CONTROL DIAGRAM MISCELLANEOUS DDC CONTROL DIAGRAM CABINET UNIT HEATER CONTROL DIAGRAM UNIT HEATER CONTROL DIAGRAM HEATING WATER SYSTEM - PIPING SCHEMATIC BAS NETWORK DIAGRAM MISCELLANEOUS PLUMBING SYSTEM CONTROL DIAGRAMMISCELLANEOUS FAN CONTROL DIAGRAMS VARIABLE AIR VOLUME TERMINAL UNIT CONTROL DIAGRAM DUCTLESS SPLIT SYSTEM CONTROL DIAGRAM ON OFF 0°F OUTSIDE AIR HWS HWS RESET SCHEDULE AS INDICATED ON HVAC PIPING PLANS (SETPOINT 15 PSID) DIFFERENTIAL PRESSURE TRANSMITTER LOCATED AT LOCATION 5HWS-DPT-1 PRIMARY HWS TEMPERATURE SECONDARY HWR TEMPERATURE SECONDARY HWS TEMPERATURE PRIMARY HWR TEMPERATURE PLUG IN 2 8 7 6 5 4 3 1 ANALOG INPUT 6 5 4 3 2 1 INPUT DIGITAL 120/24 VAC COMMUNICATION BOILER PLANT ENABLE 2 XFMR LINE 1 ANALOG OUTPUT 3 2 1 OUTPUT DIGITAL POINTS LIST OUTSIDE AIR TEMPERATURE BY DIVISION 26 120 VOLT POWER DEVICE ZONE TEMPERATURE ZONE TEMPERATURE SETPOINT MIN. REQUIRED POINTS AT BAS THROUGH MASTER BOILER CONTROLLER OR BOILER BACNET MS/TP COMMUNICATION INTERFACE SHALL INCLUDE THE FOLLOWING. TC CONTRACTOR SHALL PROVIDE ALL GRAPHICS AND REQUIRED INTERFACE FOR THESE POINTS: · BOILER START/STOP (DO, EACH BOILER) · BOILER STATUS (DI, EACH BOILER) · BOILER HWS-TEMPERATURE (AI, EACH BOILER) · BOILER FIRING RATE OVERRIDE (AO, EACH BOILER) · BOILER FIRING RATE (AI, EACH BOILER) · PHWS-TEMPERATURE (AI) · PHWR-TEMPERATURE (AI) · PHWS-TEMPERATURE SETPOINT (AO) HWS HWS HWR HWS 2 SHWR-T SHWS-T 1 3 VFD 2 5 P-2-S 2 VFD 1 4 P-1-S PHWR-T 4 6 OA-T COMMUNICATION LINE (BACnet MS/TP) MODBUS/BACnet GATEWAY BOILER HOT WATER B-1 CONDENSING MS 2 CP-1-S BOILER HOT WATER B-2 CONDENSING MS 3 CP-2-S 1 MASTER FACTORY BOILER CONTROLLER SLAVE FACTORY BOILER CONTROLLER B-1 HWS-T B-2 HWS-T PHWS-T 3 1 TO BUILDING HEATING LOAD TO BUILDING HEATING LOAD BOILER PLANT STATUS/ALARM REFER TO SPECIFICATION SECTION 23 09 23 FOR SEQUENCE OF OPERATION *HWS HWR N O RTU-4 SUPPLY FROM H-VLV NC DPT DPR H 2 1 C ZN-SET ZN-T SA SA-T 4 SUPPLY AIR TEMPERATURE VAV CONTROL DAMPER2 4 3 1 ANALOG INPUT 4 3 2 1 INPUT DIGITAL 2 4 3 1 ANALOG OUTPUT 4 3 2 1 OUTPUT DIGITAL ZONE SETPOINT ZONE TEMPERATURE SEWAGE EJECTOR ALARM MISC. EXHAUST FAN START/STOPMISCELLANEOUS EXHAUST FAN STATUS VAV HEATING COIL CONTROL VALVE AIR FLOW 1 SPARE FAN TERMINAL UNIT FAN START/STOP SPARE SUMP PUMP ALARM 3 2 EA SPACE DIFFERENTIAL PRESSURE SETPOINT EA/TA PLUG IN DEVICE 120/24 VAC COMMUNICATION XFMR LINE BY DIVISION 26 120 VOLT POWER EF-1,4,5 & TF-1, 2TF-3 EXHAUST FAN SPEED SPLIT SYSTEM FAN COIL UNIT ZONE TEMPERATURE 5 DSIU-1 DSCU-1 MANUFACTURER'S WALL MOUNTED THERMOSTAT ZN-T5 TSTAT HTG VLV N C ZONE CO2 LEVEL 6 6 ZN-CO2 TYPICAL OF (3) ZONES REFER TO FLOOR PLANS B-1 HWR HWS ET-1 HWS 399 MBH PIPE RELIEF FULL SIZE TO FLOOR DRAIN B-2 2" 399 MBH 2-1/2" 2-1/2" CP-1CP-2 2-1/2" HWR FROM BUILDING 2-1/2" HWS TO BUILDING P-1 P-2 INLINE PUMP. REFER TO DETAIL, TYP. 3/4" 2" HWR 2" AUTOMATIC AIR VENT THERMOMETER TYP. HWS HWR PIPE FULL SIZE TO FLOOR DRAIN 1" MAKE-UP RE: PLBG POT FEEDER REFER TO DETAIL CONDENSING WALL HUNG BOILER, REFER TO DETAIL TYP. HYDRAULIC SEPARATOR AS-1 2-1/2"2-1/2" TIMER SWITCH EF-9 REVERSE ACTING LINE VOLTAGE THERMOSTAT LIGHT SWITCH BY DIV. 26 EF-3,7,8 EA EF-S 1 EXHAUST FAN EF-2 ECM 4 SPACE-SP 7 POOL MECHANICAL ROOM SENSOR ATMOSPHERIC SENSING HEAD LOCATE IN A LOW WIND AREA 3 COORDINATE WALL CONTROLLER LOCATIONS WITH OWNER POWER BY E.C. LCD MULTIPLE FAN CONTROLLER HVLS CEILING FANS CF-1, 2, 3, 4A & 5A INDICATED POINTS SHALL BE CONNECTED TO THE CLOSETS DDC PANEL (I.E. A VAV TERMINAL CONTROL PANEL). DOMESTIC HOT WATER SEWAGE EJECTOR SEWAGE EJECTOR ELEVATOR SUMP INTEGRAL CONTROL PANEL PP-1-S 7 INTEGRAL CONTROL PANEL SE-1-S 5 SE-2-S 6 3 SE-ALARM 4 SP-ALARM 3 USER INTERFACE REMOTE BROWSER INTERNET LOCAL & ZONE CONTROLLERS BACnet MS/TP COMM BUS BLDG NETWORK CONTROLLER TO ADDITIONAL BACNET LOCAL CONTROLLERS 6 5 7 REFER TO SPECIFICATION SECTION 23 09 23 FOR SEQUENCE OF OPERATION SPACE DIFFERENTIAL PRESSURE 7 POINTS LIST 8FAN TERMINAL UNIT FAN STATUS 150°F 70°F 100°F SEPARATOR AS-1 AIR/DIRT/HYDRAULIC T PUMP SE-2 PUMP SE-1 RECIRC. PUMP PP-1PUMP SP-1 PUMP CP-2 PUMP P-1 PUMP P-2 PUMP CP-1 PUMP P-1 VFD CONTROL PUMP P-2 VFD CONTROL PUMP P-1 START/STOP PUMP P-2 START/STOP DIFFERENTIAL PRESSURE TRANSMITTER DPT-1 PUMP CP-1 STATUS PUMP CP-2 STATUS PUMP P-1 STATUS PUMP P-2 STATUS SEWAGE EJECTOR PUMP SE-1 STATUS SEWAGE EJECTOR PUMP SE-2 STATUS DOMESTIC HOT WATER RECIRC. PUMP PP-1 STATUS DOMESTIC HOT WATER RECIRC. PUMP PP-1 START/STOP HWR HWS HWS BOILER ROOM EPO 6 7 BOILER ROOM EPO SWITCH 8 POOL MECH. ROOM EPO SWITCH BOILER ROOM EPO 6 HARD WIRE INTERFACE TO BOILER SAFETY CIRCUITS POOL MECH. ROOM EPO 7 POOL MECH. ROOM EPO 7 HARD WIRE INTERFACE TO POOL BOILER SAFETY CIRCUITS 2 HOUR ROTARY TIMER SWITCH EF-13 12 HOUR ROTARY MOTORIZED N C DAMPER ELEVATOR SHAFT TEMPERATURE 8 FROM FIRE ALARM CONTROL SYSTEM. REFER TO DIV. 26 ECM CAT 5 CABLE BETWEEN FAN'S RJ45 JACK AND REMOTE USER TERMINAL. 5 CABINET UNIT HEATER START/STOP N C RA C H SA T-STAT STRAP-ON HTG VLV B-3 2" 399 MBH BALL VALVE TYP. CP-3 INLINE CIRCULATION PUMP. REFER TO DETAIL, TYP. BOILER HOT WATER B-3 CONDENSING MS 8 CP-3-S SLAVE FACTORY BOILER CONTROLLER B-3 HWS-T PUMP CP-3 PUMP CP-3 STATUS EF-S 1 EF-S 1 EF-S 1EF-S EF-S 1 EF-S 1 *3-WAY VALVES WILL BE USED WHERE INDICATED ON PLANS 1 1 HWR HWS HWR HWS REFER TO SPECIFICATION SECTION 23 09 23 FOR SEQUENCE OF OPERATION REFER TO SPECIFICATION SECTION 23 09 23 FOR SEQUENCE OF OPERATION EA EF-15 EF-S 1 1 2 1 ZN-SET ZN-T 2-1/2" PROVIDE AN EPO SWITCH AT EVERY DOOR SERVING THE BOILER ROOM. PROVIDE AN EPO SWITCH AT EVERY DOOR SERVING THE BOILER ROOM. 6 CEILING FAN START/STOP 6 PROVIDE 3 CONTROLLERS - (1)CF-1 & CF-2; (2)CF-3; (3- ADD ALT #2)CF-4A & CF-5A MOTORIZED N C DAMPEREF-16 EA EA 1 MOTORIZED N C DAMPER EA EF-S 1 1 EF-6,11,12,14,16,17 EA MOTORIZED N C DAMPER EA TIMER SWITCH EF-10 12 HOUR ROTARY MOTORIZED N C DAMPER EF-S 1 EA The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 4 7 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC CONTROL DRAWINGS & HEATING WATER PIPING SCHEMATIC M603 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O ROOFTOP UNIT SCHEDULE (GAS FIRED HEATING & ELECTRIC DX COOLING - RETURN FAN) PLAN SERVICE MANUFACTURER COOLING CAPACITY HEATING CAPACITY SUPPLY FAN RETURN FAN ELECTRICAL DIMENSIONS (IN) WT. REMARKS CODE & MODEL NUMBER NOMINAL TOTAL SENSIBLE AMBIENT EAT LAT UNIT MBH INPUT MBH OUTPUT TURN EAT LAT CFM CFM CFM MIN. O.A.MOTOR ESP CFM MOTOR ESP V/Φ/Hz COMP. COND. S.F. R.F. MCA MOP EER IEER H L W (LBS) TONS MBH MBH DB DB WB DB WB DAT @ S.L. @ 7,600' DOWN (°F) REQUIRED (COOLING) (MIN) (HEATING) CFM HP @ S.L. HP (IN WC) FLA FLA FLA FLA (A) (A) (°F) (°F) (°F) (°F) (°F) (DB °F) REQUIRED RATIO (°F) (MAX)(IN WC) (A) (A) (A) (A) RTU-1 GYMNASIUM DAIKIN RPS031D 30 338.9 292.6 95.0 80.3 62.3 53.7 52.8 55.0 800 582.9 20:1 42.0 95.0 13,520 6,760 13,520 4,000 20.0 1.5'' 12,170 7.5 1.00'' 460/3/60 NOTEl: 15 (4)@2.1 A 23.5 10.0 104.5 125 10.0 14.4 74'' 312'' 94'' 9,500 NOTE: 1,3,4,5,6,7,8,9,10,11,12,13,14 RTU-2 MAIN-SOUTH VAV DAIKIN RPS020D 20 243.3 176.3 95.0 79.7 64.1 54.2 53.5 55.0 320 170.1 20:1 51.7 89.6 8,500 2,550 5,525 1,400 10.0 2.0'' 7,650 7.5 1.50'' 460/3/60 NOTE: 16 (2)@2.1 A 12.9 10.0 76.8 90 9.9 13.4 74'' 267'' 94'' 9,000 NOTE: 2,4,5,6,7,8,9,10,11,12,13,14 RTU-3 MAIN & LOWER-NORTH VAV DAIKIN RPS074D 70 794.8 576.5 95.0 78.9 63.1 52.6 51.9 55.0 1,000 530.7 20:1 40.2 77.4 27,000 9,450 17,550 7,600 30.0 2.5'' 24,300 15.0 2.00'' 460/3/60 NOTE: 18 (8)@2.1 A 35.0 17.7 197.2 225 9.5 14.7 91'' 442'' 99'' 15,000 NOTE: 2,4,5,6,7,8,9,10,11,12,13,14 NOTES: 1. VAV UNIT WITH VFD ON SUPPLY FAN. CAPACITY CONTROL ON COOLING SYSTEM BY EITHER DIGITAL OR VARIABLE SPEED SCROLL COMPRESSORS.6.PROVIDE UNIT WITH DISCONNECT SWITCH.10.HINGED ACCESS DOORS AND DOOR LATCHES.15. TWO (2) COMPRESSORS @ (1)23.1 A;(2) 30.1 A. 2. SINGLE ZONE VAV SYSTEM WITH VFDS ON SUPPLY FANS, CAPACITY CONTROL ON COOLING SYSTEM BY EITHER DIGITAL OR VARIABLE SPEED SCROLL COMPRESSORS.7.MOUNT UNIT AND CURB ON 6" CONCRETE PAD. PAD SHALL EXTEND PAST UNIT FOOTPRINT 6" IN ALL DIRECTIONS. 11. PROVIDE 100% DRYBULB ECONOMIZER.16. TWO (2) COMPRESSORS @ (1)19.2 A;(2) 22.9 A. 3. PROVIDE UNIT WITH HOT-GAS REHEAT FOR DEHUMIDIFICATION CONTROL.SCHEDULED WEIGHT AND HEIGHT DO NOT INCLUDE CONCRETE PAD.12. PROVIDE A RETURN FAN WITH VFD FOR SPACE PRESSURE CONTROL. 17. THREE (3) COMPRESSORS @ (2)18.6 A; (1) 42.5 A. 4. PROVIDE UNIT WITH FACTORY MOUNTED AND TESTED CONTROLS WITH BACNET INTERFACE TO BUILDING AUTOMATION SYSTEM.8.PROVIDE UNIT WITH FACTORY FABRICATED 18" ROOF CURB. SCHEDULED WEIGHT AND HEIGHT INCLUDE ROOF CURB. 13. PROVIDE UNIT WITH OUTDOOR AIRFLOW MONITORING. 18. FOUR (4) COMPRESSORS @ (3)23.1 A; (1) 45.2 A. 5. PROVIDE UNIT WITH HAIL GUARDS OR MICROCHANNEL CONDENSER COILS.9.PROVIDE UNIT WITH MODULATING GAS HEAT.14. PROVIDE HEATING SECTION WITH STAINLESS STEEL HEAT EXCHANGER. MAKE-UP-AIR UNIT WITH (GAS FIRED HEATING & EVAPORATIVE COOLING) PLAN MANUFACTURER SERVICE LOCATION OUTSIDE AIR GAS HEAT EVAPORATIVE COOLING ELECTRICAL DIMENSIONS (IN) WT. REMARKS CODE MODEL NO.MAXIMUM MINIMUM ESP TSP MBH MBH OUTPUT MODULATION EAT LAT EVAP MEDIA FACE EAT LAT SUPPLY FAN V/Φ/Hz MCA MOP L W H (LBS) AIRFLOW AIRFLOW (IN WC) (IN WC) INPUT @ S.L. @ (7,600') (°F) (°F) EFF. VEL. DB WB DB WB (HP) (CFM) (CFM)REQUIRED (%) (FPM) (°F) (°F) (°F) (°F) MAU-1 GREENHECK IGX-112-H22 POOL MECHANICAL ROOF 3,000 1,500 1.25 1.47 400.0 234.1 8:1 -20.0 76.0 89 CELDEK 500 88.0 60.0 64.0 61.0 2.0 460/3/60 5.3 15 116'' 54'' 64'' 1,500 NOTES: 1,2,3,4,5,6,7,8 NOTES: 1. SINGLE ZONE VARIABLE AIR VOLUME UNIT. 3. MOUNT UNIT AND CURB ON 6" CONCRETE PAD. PAD SHALL EXTEND PAST UNIT FOOTPRINT 6" IN ALL DIRECTIONS. 5. PROVIDE UNIT WITH BACNET INTERFACE FOR CONTROL BY TEMPERATURE CONTROLS CONTRACTOR.7. PROVIDE AUTO DRAIN AND FILL FOR EVAPORATIVE COOLER. 2. 100% OUTSIDE AIR. DISCHARGE FROM END OF UNIT. 4. PROVIDE SUPPLY FAN WITH VFD WITH BACNET INTERFACE.6. HINGED ACCESS DOORS, INLET MOTORIZED DAMPER, DOUBLE WALL INSULATED UNIT CASING.8. PROVIDE UNIT WITH FACTORY FABRICATED 18" ROOF CURB. SCHEDULED WEIGHT AND HEIGHT INCLUDE ROOF CURB. FAN SCHEDULE PLAN MANUFACTURER TYPE SERVICE SONES CFM ESP @ S.L. MOTOR DIMENSIONS (IN) WT CONT. VIB. DAMPER REMARKS CODE & MODEL NO.(IN WC) HP RPM V/Φ/Hz H W L (LBS) ISOL. TYPE EF-1 GREENHECK G-099-VG CENT. ROOF 254 ELEC 10.2 800 0.50'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 7 NONE NOTE: 6 NOTE: 2,8,12 EF-2 GREENHECK G-143-VG CENT. ROOF 253 POOL MECH. 12.5 2,000 0.50'' 1 1,725 208/1/60 42'' 29"ø 70 NOTE: 20 NONE NOTE: 6 NOTE: 2,8,12 EF-3 GREENHECK SP-A290 CEILING 257 GUARD CHG 3.0 150 0.45'' 81 W 1,050 115/1/60 12" 12'' 14'' 25 NOTE: 3 NOTE: 22 NOTE: 18 NOTE: 4,12 EF-4 GREENHECK G-143HP-VG CENT. ROOF A102 MECHANICAL 9.9 500 0.75'' 1/4 1,500 115/1/60 44'' 29"ø 60 NOTE: 7 NONE NOTE:6 NOTE: 2,8,12 EF-5 GREENHECK G-099-VG CENT. ROOF A108 POOL STORAGE 7.9 500 0.50'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 7 NONE NOTE: 18 NOTE: 2,8,12 EF-6 GREENHECK G-143-VG CENT. ROOF EAST LOCKERS 11.0 1,550 0.75'' 1 1,725 208/1/60 42'' 29"ø 110 NOTE: 9 NONE NOTE: 6 NOTE: 2,8,12 EF-7 GREENHECK SP-A390 CEILING 203 MEN 5.5 200 0.75'' 135 W 1,350 115/1/60 12'' 14'' 12'' 25 NOTE: 3 NOTE: 22 NOTE: 18 NOTE: 4,12 EF-8 GREENHECK SP-A390 CEILING 204 WOMEN 5.5 200 0.75'' 135 W 1,350 115/1/60 12'' 14'' 12'' 25 NOTE: 3 NOTE: 22 NOTE: 18 NOTE: 4,12 EF-9 GREENHECK G-103HP-VG CENT. ROOF 275 CONFERENCE 6.8 350 0.50'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 1 NONE NOTE: 18 NOTE: 2,8,12 EF-10 GREENHECK G-143HP-VG CENT. ROOF 112 KITCHEN 10.5 550 0.75'' 1/4 1,725 115/1/60 42'' 29"ø 60 NOTE: 19 NONE NOTE: 18 NOTE: 2,8,12 EF-11 GREENHECK G-103HP-VG CENT ROOF 111 WOMEN/110 MEN 9.6 300 0.75'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 9 NONE NOTE: 6 NOTE: 2,8,12 EF-12 GREENHECK G-103-VG CENT. ROOF 105 MEN/106 WOMEN 8.9 900 0.75'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 9 NONE NOTE: 6 NOTE: 2,8,12 EF-13 GREENHECK SP-A780 CENT. ROOF 142 COM. KITCHEN 7.0 500 0.75'' 350 W 1,725 115/1/60 15'' 15'' 18'' 35 NOTE: 19 NONE NOTE: 18 NOTE: 2,8,12 EF-14 GREENHECK G-133-VG CENT. ROOF A106/A107 LOCKERS 13.2 1,400 0.75'' 3/4 1,725 115/1/60 42'' 29"ø 60 NOTE: 9 NONE NOTE: 6 NOTE: 2,8,12 EF-15 GREENHECK G-099-VG CENT. ROOF ELEVATOR 9.8 750 0.50'' 1/4 1,725 115/1/60 42'' 25"ø 50 NOTE: 14 NONE NOTE: 6 NOTE: 2,8,12 EF-16 GREENHECK SP-B150 CEILING 143 KITCHEN STORAGE 4.5 75 0.75'' 128 W 1,050 115/1/60 7'' 15'' 14'' 15 NOTE: 9 NOTE: 22 NOTE: 18 NOTE: 4,12 EF-17 GREENHECK G-143-VG CENT. ROOF WEST LOCKERS 13.3 1,900 0.75'' 1 1,725 208/1/60 42'' 29"ø 110 NOTE: 9 NONE NOTE: 6 NOTE: 2,8,12 TF-1 GREENHECK SP-A700 CEILING 282 ELEC 6.0 620 0.45'' 350 W 1,100 115/1/60 12'' 12'' 24'' 35 NOTE: 7 NOTE: 22 NOTE: 6 NOTE: 4,12 TF-2 GREENHECK SP-A700 CEILING 109 ELEC 6.0 620 0.45'' 350 W 1,100 115/1/60 12'' 12'' 24'' 35 NOTE: 7 NOTE: 22 NOTE: 6 NOTE: 4,12 TF-3 GREENHECK SP-A700 CEILING 255 POOL STORAGE 4.0 450 0.45'' 350 W 1,100 115/1/60 12'' 12'' 24'' 35 NOTE: 17 NOTE: 22 NOTE: 6 NOTE: 4,12 CF-1 & 2 MACRO AIR AIRVOLUTION D 550 CEILING CIRCULATOR 131 GYM < 53 dBA 158,000 - 1,070 W 90 460/3/60 42'' 16'ø 180 NOTE: 5 NONE NONE NOTE: 10,11,12 CF-3 MACRO AIR AIRVOLUTION D 550 CEILING CIRCULATOR 259 SPORTS POOL < 53 dBA 181,000 - 900 W 74 460/3/60 42'' 18'ø 190 NOTE: 5 NONE NONE NOTE: 10,11,12 CF-4A & 5A MACRO AIR AIRVOLUTION D 550 CEILING CIRCULATOR A110 EXIST NATATORIUM < 59 dBA 84,000 - 850 170 460/3/60 42'' 10'ø 155 NOTE: 5 NONE NONE NOTE: 10,11,12,23 NOTES: 1. FAN SHALL BE CONTROLLED BY 2 HOUR ROTARY TIMER SWITCH, LINE VOLTAGE.14. FAN SHALL BE CONTROLLED BY SPACE TEMPERATURE SENSOR. REFER TO SPECIFICATION SECTION 2. PROVIDE FAN WITH 18" TALL FACTORY FABRICATED ALUMINUM ROOF CURB. (INCLUDED IN FAN HEIGHT SHOWN) 23 09 23 FOR SEQUENCE OF OPERATION. 3. FAN SHALL BE INTERLOCKED WITH LIGHTING OCCUPANCY SENSOR.15. REFER TO DETAIL ON SHEET M700 FOR VIBRATION ISOLATION REQUIREMENTS. 4. PROVIDE FAN WITH SPEED CONTROL SWITCH.16. PROVIDE FAN WITH MANUFACTURER'S PVC "ADJUSTABLE" MANUAL VOLUME DAMPER. 5. PROVIDE BACNETY INTERFACE FOR ON/OFF CONTROL AND MANUFACTURER'S DIGITAL WALL CONTROLLER 17. FAN SHALL OPERATE CONTINUOUSLY, 24/7. WITH ON/OFF OVERRIDE & SPEED CONTROL, PROVIDE MIN. 200' CABLE.18. PROVIDE FAN WITH MOTORIZED DAMPER. 6. PROVIDE FAN WITH GRAVITY BACKDRAFT DAMPER.19. FAN SHALL BE CONTROLLED BY 12 HOUR ROTARY TIMER SWITCH, LINE VOLTAGE, BY T.C.C. 7. FAN CONTROLLED BY LINE VOLTAGE, REVERSE ACTING THERMOSTAT.20. FAN SHALL OPERATE TO CONTROL SPACE PRESSURE. REFER TO 8. PROVIDE FAN WITH EC MOTOR AND UNIT MOUNTED POTENTIOMETER FOR FAN BALANCING.SPECIFICATION SECTION 23 09 23 FOR SEQUENCE OF OPERATION. 9. FAN SHALL BE CONTROLLED BY OCCUPIED/UNOCCUPIED SCHEDULE THROUGH DDC SYSTEM. 21. PROVIDE WITH AIR INTAKE OPENING GUARD. 10. COLOR SELECTION BY ARCHITECT.22. PROVIDE WITH MANUFACTURER'S EXTERNAL ISOLATION HANGER KIT. 11. INTERLOCK FANS WITH FIRE ALARM SYSTEM. PROVIDE HARD WIRED SHUTDOWN CAPABILITY. 23. INCLUDE IN ADD ALTERNATE #2 ONLY. 12. PROVIDE INTEGRAL ELECTRIC DISCONNECT SWITCH. 13. ALL PLASTIC CONSTRUCTION. VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE (HOT WATER COIL) PLAN MANUFACTURER THERMOSTAT INLET AIR QUANTITY (CFM) INLET UNIT COIL SECTION (NOTE: 4) DIMENSIONS (IN) MAX. CONTROL VAV REMARKS CODE & MODEL NUMBER LOCATION SIZE COOLING MIN HEATING S.P.P.D. MBH GPM WPD COIL EWT EAT LAT H L W SOUND (NOTE: 5) ZONE (IN) (MAX) (IN WC) (IN WC) (FT WC) ROWS (°F) (°F) (°F) (dB) EXPOSURE VAV-2-1 TRANE VCWF A106 W. TEAM LOCKER 8 650 195 425 1.0'' 0.30 12.7 1.0 5.0 1 150.0 55.0 90.0 10'' 25'' 12'' 63 DDC PERIMETER NOTE: 1,2,3,4 VAV-2-2 TRANE VCWF A107 M. TEAM LOCKER 10 990 300 645 1.0'' 0.31 19.3 1.5 5.0 1 150.0 55.0 90.0 13'' 25'' 14'' 50 DDC PERIMETER NOTE: 1,2,3,4 VAV-2-3 TRANE VCWF 231 M. LOCKER 12 1,500 450 975 1.0'' 0.56 31.2 2.5 5.0 2 150.0 55.0 92.3 15'' 25'' 16'' 50 DDC PERIMETER NOTE: 1,2,3,4 VAV-2-4 TRANE VCWF 221 W. LOCKER 12 1,500 450 975 1.0'' 0.56 25.1 2.0 5.0 2 150.0 55.0 85.0 15'' 25'' 16'' 50 DDC INTERIOR NOTE: 1,2,3,4 VAV-2-5 TRANE VCWF 258 GUARDS 7 550 165 360 1.0'' 0.47 9.3 1.0 5.0 2 150.0 55.0 85.0 10'' 25'' 12'' 59 DDC INTERIOR NOTE: 1,2,3,4 VAV-2-6 TRANE VCWF 212 FAMILY CHANGING 6 400 120 260 1.0'' 0.30 6.7 0.5 5.0 1 150.0 55.0 85.0 8'' 25'' 12'' 49 DDC INTERIOR NOTE: 1,2,3,4 VAV-2-7 TRANE VCWF 211 PARTY ROOM 8 560 170 365 1.0'' 0.22 9.4 1.0 5.0 1 150.0 55.0 85.0 10'' 25'' 12'' 49 DDC INTERIOR NOTE: 1,2,3,4 VAV-2-8 TRANE VCWF 205 INDOOR PLAY 12 1,440 435 940 1.0'' 0.52 35.0 2.5 5.0 2 150.0 55.0 98.4 15'' 25'' 16'' 50 DDC PERIMETER NOTE: 1,2,3,4 VAV-2-9 TRANE VCWF 202 LOBBY 12 1,440 435 1,440 1.0'' 0.52 51.2 3.5 5.0 2 150.0 55.0 96.5 15'' 25'' 16'' 51 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-1 TRANE VCWF 272 DESK STAFF 8 650 230 425 1.0'' 0.30 10.9 1.0 5.0 1 150.0 55.0 85.0 10'' 25'' 12'' 44 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-2 TRANE VCWF 275 CONFERENCE 8 660 235 430 1.0'' 0.31 12.9 1.0 5.0 1 150.0 55.0 90.0 10'' 25'' 12'' 45 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-3 TRANE VCWF 277 MARKET 6 250 90 165 1.0'' 0.12 4.9 0.5 5.0 1 150.0 55.0 90.0 8'' 25'' 12''47 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-4 TRANE VCWF 281 EXEC. DIR.6 320 115 210 1.0'' 0.19 8.0 1.0 5.0 1 150.0 55.0 99.2 8'' 25'' 12'' 48 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-5 TRANE VCWF 285 FACILITY DIR.6 385 135 255 1.0'' 0.27 7.6 1.0 5.0 1 150.0 55.0 90.0 8'' 25'' 12'' 49 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-6 TRANE VCWF 278 COPY 7 435 155 285 1.0'' 0.18 7.3 0.5 5.0 1 150.0 55.0 85.0 10'' 25'' 12'' 49 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-7 TRANE VCWF 264 TRACK 24x16 3,675 1,290 2,390 1.0'' 0.00 71.7 5.0 5.0 2 150.0 55.0 90.0 18'' 25'' 38'' 50 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-8 TRANE VCWF 261 CARDIO 14 2,030 715 1,525 1.0'' 0.50 56.4 4.0 5.0 2 150.0 55.0 98.1 18'' 29'' 20'' 50 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-9 TRANE VCWF 262 MP GROUP EX.16 2,780 975 1,810 1.0'' 0.60 46.5 3.5 5.0 2 150.0 55.0 85.0 18'' 29'' 24'' 63 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-10 TRANE VCWF 124 MP GROUP EX.16 2,560 900 1,665 1.0'' 0.51 49.9 3.5 5.0 2 150.0 55.0 90.0 18'' 29'' 24'' 63 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-11 TRANE VCWF 123 STRENGTH 12 1,700 595 1,105 1.0'' 0.47 28.4 2.0 5.0 1 150.0 55.0 85.0 15'' 25'' 16'' 50 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-12 TRANE VCWF 123 STRENGTH 12 1,700 595 1,105 1.0'' 0.47 28.4 2.0 5.0 1 150.0 55.0 85.0 15'' 25'' 16'' 59 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-13 TRANE VCWF 121 JR GOLF 6 375 135 245 1.0'' 0.47 6.3 0.5 5.0 1 150.0 55.0 85.0 8'' 25'' 12'' 59 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-14 TRANE VCWF CLASSROOM 10 905 320 905 1.0'' 0.47 23.3 2.0 5.0 1 150.0 55.0 85.0 13'' 25'' 14'' 59 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-15 TRANE VCWF 112 KITCHEN 6 150 55 100 1.0'' 0.47 3.0 0.5 5.0 1 150.0 55.0 90.0 8'' 25'' 12''63 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-16 TRANE VCWF 102 LOUNGE 10 1,100 385 715 1.0'' 0.47 21.4 1.5 5.0 1 150.0 55.0 90.0 13'' 25'' 14'' 63 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-17 TRANE VCWF 108 P&R DIRECTOR 7 485 170 320 1.0'' 0.47 8.2 1.0 5.0 1 150.0 55.0 85.0 10'' 25'' 12'' 63 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-18 TRANE VCWF 106 GAMES 10 1,095 385 715 1.0'' 0.38 18.4 1.5 5.0 1 150.0 55.0 85.0 13'' 25'' 14'' 33 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-19 TRANE VCWF 141 COMMUNITY 14 1,880 660 1,225 1.0'' 0.43 36.7 2.5 5.0 2 150.0 55.0 90.0 18'' 29'' 20'' 34 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-20 TRANE VCWF 141 COMMUNITY 16 2,600 910 1,690 1.0'' 0.53 50.7 3.5 5.0 2 150.0 55.0 90.0 18'' 29'' 24'' 35 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-21 TRANE VCWF 141 COMMUNITY 14 2,280 800 1,485 1.0'' 0.63 44.5 3.0 5.0 2 150.0 55.0 90.0 18'' 29'' 20'' 36 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-22 TRANE VCWF 142 KITCHEN 10 1,100 715 715 1.0'' 0.38 26.1 2.0 5.0 1 150.0 55.0 97.7 13'' 25'' 14'' 37 DDC PERIMETER NOTE: 1,2,3,4 VAV-3-23 TRANE VCWF 261 CARDIO SOUTH 10 1,025 360 720 1.0'' 0.33 27.6 2.0 5.0 1 150.0 55.0 99.8 13'' 25'' 14'' 38 DDC INTERIOR NOTE: 1,2,3,4 VAV-3-24 TRANE VCWF 202 LOBBY 7 550 195 495 2.0'' 0.00 16.6 1.5 5.0 1 150.0 55.0 94.2 10'' 25'' 12'' 39 DDC INTERIOR NOTE: 1,2,3,4 NOTES: 1. MAXIMUM SOUND POWER SCHEDULED IS END DISCHARGE SOUND POWER LEVEL BASED ON MAXIMUM SCHEDULED AIRFLOW 4. HEATING COIL DUTY RATED AT HEATING CFM. AT 1.0" WC INLET PRESSURE AT 500 Hz. OCTAVE BAND. REFER TO SPECIFICATION FOR FURTHER SOUND REQUIREMENTS. 5. UNIT CONTROLS ARE DIRECT DIGITAL CONTROL (DDC), BY T.C.C. 2. MAXIMUM DIFFERENTIAL PRESSURE IS AT MAXIMUM SCHEDULED AIRFLOW WITH REHEAT COIL WHERE INDICATED. 6. PROVIDE COIL WITH 3-WAY VALVE. 3. SELECT HEATING COIL ASSUMING 0% GLYCOL SOLUTION AND ELEVATION OF 7,600' ABOVE SEA LEVEL. NATATORIUM DEHUMIDIFICATION/HEAT RECOVERY UNIT SCHEDULE PLAN MANUFACTURER SERVICE HEAT EXCHANGER DIRECT DRIVE FANS HEATING ELECTRICAL DIMENSIONS (IN) WT. REMARKS CODE & MODEL NO. MODEL MODE CFM EAT LAT APD MODE CFM EAT LAT APD SERVICE TOTAL CFM PER SIZE/ TYPE ESP RPM BHP MHP INPUT OUTPUT EAT LAT V/Φ/Hz DISC. MOP MCA L W H (LB) DB/WB (°F) DB/WB (°F) (IN WC) DB (°F)/%RH DB (°F) (IN WC) CFM FAN NUMBER (IN WC) (MBH) MBH@ALT DB (°F) DB (°F) SIZE PDU-1A INNOVENT NDHU-OU-PL-15700- IF-460 A110 EXIST. NATATORIUM H-1-40C-1350 WINTER OA 7,900 -20.0 43.6/26.8 0.37'' WINTER EA 9,470 86.0/31.0 42.4 0.67'' SUPPLY 15,700 7,850 24"/2 AF-PLN 2.0'' 1,848 (2)@7.5 (2)@10 1,000 580 63 108.2 460/3/60 60 50 39 354'' 100'' 120'' 12,500 NOTE: 1,2,3,4,5,6,7 PURGE OA - - - - PURGE EA - - - - SUMMER OA 7,900 88.0/60.0 86.8/59.6 0.61'' SUMMER EA 9,470 86.0/60.1 86.9 0.79'' EXHAUST 9,470 NA 22"/1 AF-PLN 1.5'' 1,939 7.0 10.0 DEW POINT OA - - - - DEW POINT EA - - - - PDU-2 INNOVENT NDHU-OU-PL-14700- IF-460 251 NATATORIUM H-1-40C-1350 WINTER OA 7,400 -20.0 44.2/27.1 0.37'' WINTER EA 8,870 86.0/31.0 42.1 0.66'' SUPPLY 14,700 7,350 24"/2 AF-PLN 2.0'' 1,809 (2)@7.0 (2)@10 800 464 65.1 103.7 460/3/60 60 45 36.4 300'' 100'' 111'' 11,000 NOTE: 1,2,3,4,5,6 PURGE OA - - - 0.48'' PURGE EA - - - - SUMMER OA 7,400 88.0/60.0 86.8/59.6 0.60'' SUMMER EA 8,870 86.0/60.1 86.9 0.79'' EXHAUST 8,870 NA 22"/1 AF-PLN 1.5'' 1,865 6.3 7.5 DEW POINT OA - - - 0.57'' DEW POINT EA - - - - NOTES: 1. PROVIDE UNIT WITH FACTORY FABRICATED 18" ROOF CURB. SCHEDULED WEIGHT & HEIGHT INCLUDE ROOF CURB. 3. PROVIDE WITH 2" MERV 8 OUTSIDE AIR FILTERS & 2" WASHABLE ALUMINUM RETURN AIR FILTERS. 5. MOUNT UNIT AND CURB ON 6" CONCRETE PAD. PAD SHALL EXTEND PAST UNIT FOOTPRINT 4" IN ALL DIRECTIONS. 6. INTEGRAL CONTROLS WITH BACNET INTERFACE. 2. CAPACITY CONTROL ON COOLING SYSTEM BY DIGITAL SCROLL COMPRESSOR.4. VFD ON SUPPLY AND EXHAUST FAN ARRAYS.SCHEDULED WEIGHT AND HEIGHT DO NOT INCLUDE CONCRETE PAD.7. INCLUDE IN ADD ALTERNATE #2 ONLY. The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 5 0 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC SCHEDULES M701 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O DUCTLESS SPLIT SYSTEM (INDOOR UNIT AND CONDENSING UNIT) SCHEDULE PLAN MANUFACTURER & SERVICE SUPPLY FAN DX COOLING COIL OPER.PLAN MANUFACTURER CAPACITY AMBIENT ELECTRICAL DIMENSIONS (IN) WT. REMARKS CODE MODEL NUMBER CFM ESP POWER V/Φ/Hz TOTAL SENS. EAT (°F)SIZE (IN) WT. CODE & MODEL NO. TONS MBH SEER (°F) MCA MOP V/Φ/Hz H L W (LBS) (IN WC) MBH MBH DB WB H L W (LBS) DSIU-1 DAIKIN FTXS36LVJU 276 LAN 770 - NOTE: 7 230/1/60 36.0 22.9 80.0 67.0 14'' 48'' 10'' 38 DSCU-1 DAIKIN RXS36LVJU 3.0 36.0 17.9 88 19.5 20.0 230/1/60 39'' 37'' 13'' 180 NOTES: 1,2,3,4,5,6,8,9,10 NOTES: 1. PROVIDE WITH FACTORY INSTALLED ELECTRIC DISCONNECT SWITCH. 3. INTEGRAL MICROPROCESSOR CONTROL SYSTEM.5.WASHABLE FILTER. 7. INDOOR UNIT, DSIU-1, IS FED FROM OUTDOOR UNIT, DSCU-1. BOTH UNITS HAVE SAME ELECTRICAL REQUIREMENTS. 9. MOUNT UNIT AND CURB ON 6" CONCRETE PAD. PAD SHALL EXTEND PAST UNIT FOOTPRINT 4" IN ALL DIRECTIONS. 2. LOW AMBIENT CONTROL, CRANKCASE HEATER AND WIND BAFFLE. 4. REFRIGERANT LINE SET - SIZED BY SUPPLIER.6.R-410A REFRIGERANT. 8. PROVIDE WITH MANUFACTURER'S WALL MOUNTED THERMOSTAT.10. PROVIDE UNIT WITH ULTRA LOW AMBIENT COOLING KIT. LOUVER SCHEDULE PLAN MANUFACTURER SERVICE FREE AREA CFM VELOCITY APD MOUNTING MATERIALS DIMENSIONS (IN) REMARKS CODE & MODEL NO.(SF) (FPM) (IN WC) TYPE L H W LVR-1 RUSKIN ELF375DXH PDU-1 RETURN/EXHAUST 29.1 17,200 591 0.07 FLANGED NOTE: 3 72'' 104'' 4'' NOTE: 1,2,4 LVR-2 RUSKIN ELF375DXH PDU-2 RETURN/EXHAUST 17.7 9,570 541 0.06 FLANGED NOTE: 3 64'' 72'' 4" NOTE: 1,2,4 LVR-3 RUSKIN ELF375DXH PDU-2 RETURN/EXHAUST 17.7 9,570 541 0.06 FLANGED NOTE: 3 64'' 72'' 4" NOTE: 1,2,4 LVR-4 RUSKIN ELF375DX RTU-2 RETURN 10.2 7,100 695 0.10 FLANGED NOTE: 3 56'' 48'' 4" NOTE: 1,2 NOTES: 1. PROVIDE LOUVER WITH PRIME COAT FINISH. LOUVER SHALL BE PAINTED IN FIELD. 3. EXTRUDED ALUMINUM. 2. PROVIDE LOUVER WITH 1/2" BIRD SCREEN.4. HEAVY GAUGE CONSTRUCTION. UNIT HEATER SCHEDULE (HOT WATER) PLAN MANUFACTURER LOCATION MBH CFM EAT EWT LWT GPM WPD ELECTRICAL DISCHARGE MOUNTING OPER. CONTROL REMARKS CODE & MODEL NO.(°F) (°F) (°F) (FT) W V/Φ/Hz MCA RPM TYPE HEIGHT (FT) WT (LBS) UH-1 TRANE UHS 018 273 WATER ENTRY 6.0 395 55.0 150.0 130.0 1.3 0.005 16 115/1/60 1 1,550 VERTICAL 8'-0" 40 NOTE: 1 NOTE: 2,3,5 UH-2 TRANE UHS 018 A108 POOL STORAGE 6.0 395 55.0 150.0 130.0 1.3 0.005 16 115/1/60 1 1,550 VERTICAL 8'-0" 40 NOTE: 1 NOTE: 2,3,5 UH-3 TRANE UHS 018 A114 EXIST. POOL EQ. 6.0 395 55.0 150.0 130.0 1.3 0.005 16 115/1/60 1 1,550 VERTICAL 8'-0" 40 NOTE: 1 NOTE: 2,3,5 UH-4 TRANE UHS 018 115 RECEIVING 6.0 395 55.0 150.0 130.0 1.3 0.005 16 115/1/60 1 1,550 VERTICAL 8'-0" 40 NOTE: 1 NOTE: 2,3,5 UH-5 TRANE UHS 018 132 GYM STORAGE 6.0 395 55.0 150.0 130.0 1.3 0.005 16 115/1/60 1 1,550 VERTICAL 8'-0" 40 NOTE: 1 NOTE: 2,3,4,5 NOTES: 1. UNIT MOUNTED THERMOSTAT BY UNIT MANUFACTURER. 3. PROVIDE UNIT WITH MANUFACTURER'S FAN GUARD. 5. PROVIDE UNIT WITH INTEGRAL ELECTRIC DISCONNECT SWITCH & FAN SPEED SWITCH. 2. HOT WATER SYSTEM UTILIZES 0% GLYCOL SOLUTION. 4. PROVIDE COIL WITH 3-WAY CONTROL VALVE. GRILLES, REGISTERS & DIFFUSERS SCHEDULE PLAN MANUFACTURER SERVICE NECK FACE SLOT WIDTH/ VOLUME MATERIAL MOUNTING FINISH REMARKS CODE & MODEL NO. SIZE SIZE NO. OF SLOTS DAMPER TYPE CD-1 PRICE AMD SUPPLY AS NOTED 24"x24" - NO ALUMINUM LAY-IN WHITE NOTE: 5,13 CD-1A PRICE AMD SUPPLY AS NOTED 24"x24" - NO ALUMINUM LAY-IN WHITE NOTE: 3,5,13 CD-2 PRICE AMD SUPPLY AS NOTED 12"x12" - NO ALUMINUM SURFACE WHITE NOTE: 8,12,13 SD-1 PRICE SDB SUPPLY AS NOTED 48"x4.25" 1"/2 NO STEEL LAY-IN WHITE NOTE: 6 SD-2 PRICE SDA SUPPLY AS NOTED 48"x4.25" 1"/2 NOTE: 11 ALUMINUM SURFACE WHITE NOTE: 6,10 SR-1 PRICE AHCD2 SUPPLY AS NOTED NECK + 2.6" - NOTE: 1 ALUMINUM DUCT NOTE: 2,4 NOTE: 14 SR-2 PRICE HCD2 SUPPLY AS NOTED NECK + 2.6" - NOTE: 1 STEEL DUCT NOTE: 2,4 NOTE: 14 SR-3 AIR CONCEPTS RDDW-RD SUPPLY AS NOTED NECK + 1/8" - NOTE: 15 ALUMINUM DUCT END NOTE: 2,16 SR-4 PRICE SDGE SUPPLY AS NOTED NECK + 1.75" - NOTE: 17 ALUMINUM DUCT NOTE: 2,16 SG-1 PRICE 620 SUPPLY AS NOTED NECK + 1.75" - NO ALUMINUM DUCT NOTE: 2,16 SG-2 PRICE 620 SUPPLY AS NOTED NECK + 1.75" - NO ALUMINUM SURFACE WHITE SG-3 PRICE ND SUPPLY AS NOTED NECK + 1/16" - NO ALUMINUM SURFACE WHITE NOTE: 9 EG-1 PRICE 630 EXHAUST AS NOTED NECK + 1.75" - NO ALUMINUM SURFACE WHITE EG-2 PRICE 630 EXHAUST AS NOTED 12"x24" - NO ALUMINUM LAY-IN WHITE EG-3 PRICE 630 EXHAUST AS NOTED NECK + 1.75" - NO ALUMINUM DUCT NOTE: 2,16 EG-4 PRICE 630 EXHAUST AS NOTED 24"x24" - NO ALUMINUM LAY-IN WHITE RG-1 PRICE PFRF RETURN NONE 24"x12" - NO STEEL LAY-IN WHITE RG-2 PRICE PFRF RETURN NONE 24"x24" - NO STEEL LAY-IN WHITE RG-3 PRICE PDDR RETURN 18"x12" 24"x12" - NO ALUMINUM LAY-IN WHITE NOTE: 7 RG-4 PRICE PDDR RETURN 18"x18" 24"x24" - NO ALUMINUM LAY-IN WHITE NOTE: 7 TG-1 PRICE 630 TRANSFER AS NOTED NECK + 1.75" - NO ALUMINUM SURFACE WHITE TG-2 PRICE AMD TRANSFER AS NOTED 24"x24" - NO ALUMINUM LAY-IN WHITE NOTE: 5,13 TG-3 PRICE ND TRANSFER AS NOTED NECK + 1/16" - NO ALUMINUM SURFACE WHITE NOTE: 9 NOTES: 1. PROVIDE AIR DEVICE WITH OPPOSED BLADE MANUAL VOLUME DAMPER. 10. DRYWALL CONTRACTOR TO PLASTER OVER FRAME SO ONLY SLOTS ARE VISIBLE. PROVIDE WITH HARD CEILING BRACKET. 2. AIR DEVICE TO BE FIELD PAINTED TO MATCH DUCTWORK.11. PROVIDE AIR DEVICE WITH FACE ADJUSTABLE QUADRANT DAMPER. 3. PROVIDE AIR DEVICE WITH TWO-WAY OPPOSITE THROW. 12. PROVIDE WITH FULL 9"x9" LOUVERED FACE. 4. PROVIDE AIR DEVICE WITH CLEAR ANODIZED FINISH. 13.REFER TO INSTALLATION DETAIL ON SHEET M501. 5. PROVIDE AIR DEVICE WITH FULL 18"x18" LOUVERED FACE. 14. MOUNT AIR DEVICE ONTO DUCTWORK WITH CURVED PLENUM BOX. REFER TO DETAIL ON SHEET M501. 6. PROVIDE AIR DEVICE WITH INSULATED PLENUM.15. PROVIDE AIR DEVICE WITH RADIAL BLADE MANUAL VOLUME DAMPER. 7. PROVIDE AIR DEVICE WITH SOUND BOOT. REFER TO DETAIL ON SHEET M501. 16. PROVIDE AIR DEVICE WITH PRIME COAT FINISH. 8. PROVIDE AIR DEVICE WITH MANUFACTURER SUPPLIED HARD LID TRIM KIT. 17. PROVIDE AIR DEVICE WITH AIR MANUAL VOLUME DAMPER/AIR EXTRACTOR. 9. PROVIDE AIR DEVICE WITH PRICE SM FRAME. PUMP SCHEDULE PLAN MANUFACTURER TYPE SERVICE IMP. Ø GPM TDH % ELECTRICAL DIMENSIONS (IN) WT. REMARKS CODE & MODEL NO.(IN) (FT WC) EFF. HP N.O.L. HP V/Φ/Hz RPM W H L (LBS) P-1 GRUNDFOS TPE 40-240 INLINE HEATING WATER - 40.0 45.0 49.3 1.5 - 460/3/60 3,450 14'' 18'' 10'' 100 NOTE: 1,2,3 P-2 GRUNDFOS TPE 40-240 INLINE HEATING WATER - 40.0 45.0 49.3 1.5 - 460/3/60 3,450 14'' 18'' 10'' 100 NOTE: 1,2,3 CP-1 GRUNDFOS UPS 43-44 INLINE BOILER B-1 2 20.0 11.0 40.0 1/6 - 115/1/60 - 5'' 7'' 9'' 20 NOTE: 1 CP-2 GRUNDFOS UPS 43-44 INLINE BOILER B-2 2 20.0 11.0 40.0 1/6 - 115/1/60 - 5'' 7'' 9'' 20 NOTE: 1 CP-3 GRUNDFOS UPS 43-44 INLINE BOILER B-3 2 20.0 11.0 40.0 1/6 - 115/1/60 - 5'' 7'' 9'' 20 NOTE: 1 NOTES: 1. HEATING WATER SYSTEM UTILIZES 0% GLYCOL.3. PROVIDE PUMP WITH BACNET CIM MODULE TO INTERFACE WITH DDC SYSTEM. 2. PROVIDE PUMP WITH MOTOR MOUNTED VFD, FACTORY INSTALLED AND WIRED. EXPANSION TANK SCHEDULE PLAN MANUFACTURER SERVICE TANK ACCEPT. SYSTEM FILL AVG. DESIGN MIN. OPER. MAX. OPER. DIMENSIONS (IN) OPER. REMARKS CODE & MODEL NO. VOLUME VOLUME VOLUME TEMP TEMPERATURE PRESSURE PRESSURE ø H WT. (GAL) (GAL) (GAL) (°F) (°F) (PSI) (PSI) (LBS) ET-1 ARMSTRONG-AX-40V HEATING WATER 25.0 20.2 280 40.0 150.0 12.0 27.0 16'' 33'' 255 NOTE: 1,2 NOTES: 1.HOT WATER SYSTEM CONTAINS 0% PROPYLENE GLYCOL. 2. SYSTEM VOLUME IS TOTAL VOLUME. 3. TANK CONSTRUCTION RATED FOR 125 PSI. CONDENSING WATER BOILER SCHEDULE PLAN MANUFACTURER SERVICE MBH MBH WATER RELIEF OPER. V/Φ/Hz MCA LWT WATER WPD SIZE (IN) OPER. REMARKS CODE & MODEL NO. INPUT OUTPUT VOLUME VALVE PRES. (°F) FLOW (FT WC) L W H WT. @S.L. @7,600' (GAL) (PSI) (PSIG) (GPM) (LBS) B-1 TRIANGLE TUBE PRESTIGE 399 HEATING WATER 399.0 292.3 7.0 30.0 30.0 120/1/60 15 150.0 20.0 4.0 25'' 21'' 38'' 200 NOTE: 1,2,3,4,5,6,7,8 B-2 TRIANGLE TUBE PRESTIGE 399 HEATING WATER 399.0 292.3 7.0 30.0 30.0 120/1/60 15 150.0 20.0 4.0 25'' 21'' 38'' 200 NOTE: 1,2,3,4,5,6,7,8 B-3 TRIANGLE TUBE PRESTIGE 399 HEATING WATER 399.0 292.3 7.0 30.0 30.0 120/1/60 15 150.0 20.0 4.0 25'' 21'' 38'' 200 NOTE: 1,2,3,4,5,6,7,8 NOTES: 1. BOILERS SHALL BE CONTROLLED AND STAGED BY FACTORY SUPPLIED CASCADE BOILER PLANT CONTROL/STAGING PANEL. 6. PROVIDE WITH 30 PSI RELIEF VALVE. 2. PROVIDE CONDENSING BOILER WITH AXIOM NC-1 CONDENSATE NEUTRALIZATION KIT OR EQUIVALENT.7. PROVIDE WITH EXTERNAL LOW WATER CUTOFF, MCDONNELL & MILLER GUARD DOG, MODEL RB-122-E. 3. GAS TRAIN RATED FOR 4" TO 14" GAS INLET PRESSURE.8. FACTORY STARTUP REQUIRED. 4. PROVIDE MANUFACTURER'S WALL HANGING KIT. 5. BOILER SYSTEM UTILIZIES 0% GLYCOL SOLUTION. CABINET UNIT HEATER SCHEDULE (HOT WATER) PLAN MANUFACTURER LOCATION MBH CFM EAT DB EWT LWT FLOW WPD ELECTRICAL DIMENSIONS (IN) OPER. CONTROL REMARKS CODE & MODEL NO. (°F) (°F) (°F) (GPM) (FT WC) W V/Φ/Hz MCA RPM W L H WT. (LBS) CUH-1 TRANE FF 040 201 VESTIBULE 14.2 338 60.0 150.0 110.0 0.8 1.1 58 115/1/60 2.8 1,080 10'' 38'' 30'' 85 NOTE: 12 NOTE: 2,3,4,6,7,8,9 CUH-2 TRANE FF 040 (E) S. VESTIBULE 14.2 338 60.0 150.0 110.0 0.8 1.1 58 115/1/60 2.8 1,080 10'' 38'' 30'' 85 NOTE: 10 NOTE: 2,3,4,6,7,8,9 CUH-3 TRANE FF 040 101 VEST 14.2 338 60.0 150.0 110.0 0.8 1.1 58 115/1/60 2.8 1,080 10'' 66'' 30'' 85 NOTE: 12 NOTE: 2,3,5,6,7,8,9 CUH-4 TRANE FF 040 104 EMP. ENTRY 14.2 338 60.0 150.0 110.0 0.8 1.1 58 115/1/60 2.8 1,080 26'' 38'' 10'' 85 NOTE: 12 NOTE: 2,3,6,7,8,9,13 CUH-5 TRANE FF 120 133 EXIT STAIR 34.9 921 60.0 150.0 110.0 1.8 0.7 160 115/1/60 6.1 NOTE: 1 10'' 76'' 26'' 220 NOTE: 10 NOTE: 2,3,5,6,7,8,9,11 NOTES: 1. (2) MOTORS: (1)@1.3 HP &1,096 RPM, & (1)@0.22 HP &1,092 RPM.8. PROVIDE UNIT WITH THROW AWAY FILTRATION. 2. HOT WATER SYSTEM UTILIZES 0% GLYCOL SOLUTION.9. PROVIDE UNIT WITH 2 ROW COIL. 3. PROVIDE UNIT WITH MANUAL RESET.10. PROVIDE WITH MANUFACTURER'S UNIT MOUNTED THERMOSTAT. 4. HORIZONTAL RECESSED CABINET, BOTTOM STAMPED LOUVER INLET, BOTTOM STAMPED LOUVER OUTLET. 11. PROVIDE COIL WITH 3-WAY CONTROL VALVE. 5. VERTICAL CABINET, FRONT TOE SPACE INLET, FRONT STAMPED LOUVER OUTLET.12. PROVIDE WITH MANUFACTURER'S WALL MOUNTED DDC TEMPERATURE SENSOR. 6. UNIT MOUNTED ELECTRIC DISCONNECT SWITCH AND FAN SPEED SWITCH.13. HORIZONTAL CABINET, BOTTOM STAMPED LOUVER INLET, BOTTOM STAMPED LOUVER OUTLET. 7. SUBMIT COLOR CHARTS FOR STANDARD COLOR SELECTION BY ARCHITECT. PERFORATED DUCT SCHEDULE PLAN MANUFACTURER & SERVICE ø LENGTH CFM FACE VELOCITY (FPM) FREE MAX. PD REMARKS CODE MODEL NO. (IN) (IN) AREA (SF) (IN WC) RD-1 MCGILL AIRFLOW DDF-DSPA RTU-1 RETURN 40 120 13,500 561 24 0.12 NOTE: 1,2,3 NOTES: 1. 360°PERFORATION. 23% MINIMUM FREE AREA 2 DUCT SHALL TERMINATE WITH PERFORATED DUCT CAP. 3. GALVANIZED SPIRAL PERFORATED DUCT. SOUND ATTENUATOR SCHEDULE PLAN MANUFACTURER & SERVICE DIMENSIONS (IN) VELOCITY CFM MAX PD DYNAMIC INSERTION LOSS (DB) REMARKS CODE MODEL NUMBER L W H (FPM) (IN WC) 63 125 250 500 1000 2000 4000 8000 SA-1 VIBRO ACOUSTICS RNM-XV-FX PDU-2 EXHAUST 60'' 40'' 32'' 998 8,870 0.26 6 6 11 16 14 11 9 8 NOTE: 1,2 NOTES: 1. NO-MEDIA SILENCER CONSTRUCTION. FIBROUS MEDIA OR FILM LINED MEDIA PROTECTION NOT ACCEPTABLE. 2. ALUMINUM CONSTRUCTION. The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 5 2 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC SCHEDULES M702 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 2015 IMC MINIMUM OUTDOOR AIR REQUIREMENTS PROJECT NAME: ESTES VALLEY COMMUNITY CENTER DATE:2016-10-31 SYSTEM TAG: RTU-1 PROJECT #: 16023 BY: AB CONDITION ALALYZED: HEATING ROOM NAME ROOM NUMBER ZONE TAG OCCUPANCY CATEGORY FLOOR AREA (SF) DESIGN POPULATION (# OF PEOPLE) OA PER PERSON (CFM/PERSON) (Rp) OA/SF (Ra) AIR DISTRIBUTION TYPE ZONE AIR DISTRIBUTION EFFECTIVENESS (Ez) REQUIRED OA TO ZONE (CFM) (Voz) MAXIMUM PRIMARY AIR TO ROOM (CFM) PERCENTAGE OF PRIMARY AIR TO ROOM AT CONDITION ANALYZED PRIMARY AIR TO ROOM AT CONDITION ANALYZED (CFM) PRIMARY OUTDOOR AIR FRACTION (Zpz) ZONE VENT. EFF. (Evz) GYMNASIUM 131 - GYM, STADIUM (PLAY AREA) 13,000 152 0 0.3 CSCRH 1 3,900 13,520 90% 12168 0.32 1.00 FLOOR AREA SERVED BY SYSTEM (As )13,000 SF ASHRAE 62.1-2013 TABLE 6.2.5.2 POPULATION OF SYSTEM (Ps )152 MAX Zp 0.32 OA REQUIRED PER UNIT AREA FOR SYSTEM (AVG)(Ras )0.30 CFM SYSTEM VENTILATION EFFICIENCY (Ev )0.83 OA REQUIRED PER PERSON FOR SYSTEM AREA (AVG)(Rps )0.00 CFM ASHRAE 62.1-2013 NORMATIVE APPENDIX A: UNCORRECTED OUTDOOR AIR INTAKE (Vou )3,900 CFM AVERAGE OUTDOOR AIR FRACTION (Xs )0.32 DESIGN PRIMARY SUPPLY FAN AIRFLOW (Vps )12,168 CFM SYSTEM VENTILATION EFFICIENCY (Ev )1.00 TOTAL REQUIRED OUTDOOR AIR INTAKE FLOW RATE*(Vot)3,900 CFM *USING SYSTEM VENTILATION EFFICIENCY (Ev) AS CALCULATED BY APPENDIX A TOTAL OUTDOOR AIR PROVIDED 4,000 CFM 2015 IMC MINIMUM OUTDOOR AIR REQUIREMENTS PROJECT NAME: ESTES VALLEY COMMUNITY CENTER DATE:2016-10-31 SYSTEM TAG: RTU-2 PROJECT #: 16023 BY: AB CONDITION ALALYZED: HEATING ROOM NAME ROOM NUMBER ZONE TAG OCCUPANCY CATEGORY FLOOR AREA (SF) DESIGN POPULATION (# OF PEOPLE) OA PER PERSON (CFM/PERSON) (Rp) OA/SF (Ra) AIR DISTRIBUTION TYPE ZONE AIR DISTRIBUTION EFFECTIVENESS (Ez) REQUIRED OA TO ZONE (CFM) (Voz) MAXIMUM PRIMARY AIR TO ROOM (CFM) PERCENTAGE OF PRIMARY AIR TO ROOM AT CONDITION ANALYZED PRIMARY AIR TO ROOM AT CONDITION ANALYZED (CFM) PRIMARY OUTDOOR AIR FRACTION (Zpz) ZONE VENT. EFF. (Evz) W. TEAM LOCKER A106 VAV-2-1 LOCKER/DRESSING ROOMS 607 18 0 0 CSCRH 0.8 0 650 65% 422.50 0.00 1.13 M. TEAM LOCKER A107 VAV-2-2 LOCKER/DRESSING ROOMS 509 16 0 0 CSCRH 0.8 0 550 65% 357.50 0.00 1.13 POOL STORAGE A108 VAV-2-2 STORAGE ROOMS 863 0 0 0.12 CSCRH 0.8 129 440 65% 286.00 0.45 0.68 MENS LOCKER 231 VAV-2-3 LOCKER/DRESSING ROOMS 1,568 48 0 0 CSCRH 0.8 0 1,600 65% 1040.00 0.00 1.13 MENS SHOWERS 232 VAV-2-3 TOILET ROOMS - PUBLIC 214 0 0 0 CSCRH 0.8 0 150 65% 97.50 0.00 1.13 MENS TOILETS 233 VAV-2-3 TOILET ROOMS - PUBLIC 201 0 0 0 CSCRH 0.8 0 150 65% 97.50 0.00 1.13 WOMENS LOCKERS 221 VAV-2-4 LOCKER/DRESSING ROOMS 1,525 48 0 0 CSCRH 0.8 0 1,600 65% 1040.00 0.00 1.13 WOMENS SHOWERS 222 VAV-2-4 TOILET ROOMS - PUBLIC 205 0 0 0 CSCRH 0.8 0 150 65% 97.50 0.00 1.13 WOMENS TOILETS 223 VAV-2-4 TOILET ROOMS - PUBLIC 186 0 0 0 CSCRH 0.8 0 150 65% 97.50 0.00 1.13 POOL OFFICE 256 VAV-2-5 OFFICE SPACE 100 1 5 0.06 CSCRH 0.8 14 100 65% 65.00 0.21 0.92 LIFEGUARD CHANGING 257 VAV-2-5 LOCKER/DRESSING ROOMS 82 0 0 0 CSCRH 0.8 0 75 65% 48.75 0.00 1.13 LIFEGUARDS 258 VAV-2-5 OFFICE SPACE 247 2 5 0.06 CSCRH 0.8 31 250 65% 162.50 0.19 0.94 CIRCULATION 259 VAV-2-5 CORRIDORS 251 0 0 0.06 CSCRH 0.8 19 125 65% 81.25 0.23 0.90 FAMILY CHANGING 212 VAV-2-6 LOCKER/DRESSING ROOMS 248 8 0 0 CSCRH 0.8 0 250 65% 162.50 0.00 1.13 ACR1 213 VAV-2-6 TOILET ROOMS - PUBLIC 75 0 0 0 CSCRH 0.8 0 50 65% 32.50 0.00 1.13 ACR2 214 VAV-2-6 TOILET ROOMS - PUBLIC 69 0 0 0 CSCRH 0.8 0 50 65% 32.50 0.00 1.13 CHG 215 VAV-2-7 TOILET ROOMS - PUBLIC 37 0 0 0 CSCRH 0.8 0 35 65% 22.75 0.00 1.13 ACR3 216 VAV-2-6 TOILET ROOMS - PUBLIC 69 0 0 0 CSCRH 0.8 0 50 65% 32.50 0.00 1.13 PARTY ROOM 211 VAV-2-7 MULTIPURPOSE ASSEMBLY 283 10 5 0.06 CSCRH 0.8 84 560 65% 364.00 0.23 0.90 INDOOR PLAY 205 VAV-2-8 DAYCARE (THROUGH AGE 4) 502 15 10 0.18 CSCRH 0.8 300 900 65% 585.00 0.51 0.62 OFFICE 206 VAV-2-8 OFFICE SPACE 42 1 5 0.06 CSCRH 0.8 9 50 65% 32.50 0.29 0.84 KIDS TOILET 207 VAV-2-8 TOILET ROOMS - PUBLIC 50 0 0 0 CSCRH 0.8 0 40 65% 26.00 0.00 1.13 KID WATCH 288 VAV-2-8 DAYCARE (THROUGH AGE 4) 224 6 10 0.18 CSCRH 0.8 125 450 65% 292.50 0.43 0.70 LOBBY 202 VAV-2-9 LOBBIES 1,764 36 5 0.06 CSCRH 0.8 357 1,440 65% 936.00 0.38 0.75 FLOOR AREA SERVED BY SYSTEM (As )9,921 SF ASHRAE 62.1-2013 TABLE 6.2.5.2 POPULATION OF SYSTEM (Ps )209 MAX Zp 0.51 OA REQUIRED PER UNIT AREA FOR SYSTEM (AVG)(Ras )0.04 CFM SYSTEM VENTILATION EFFICIENCY (Ev )0.64 OA REQUIRED PER PERSON FOR SYSTEM AREA (AVG)(Rps )2.20 CFM ASHRAE 62.1-2013 NORMATIVE APPENDIX A: UNCORRECTED OUTDOOR AIR INTAKE (Vou )855 CFM AVERAGE OUTDOOR AIR FRACTION (Xs )0.13 DESIGN PRIMARY SUPPLY FAN AIRFLOW (Vps )6,412 CFM SYSTEM VENTILATION EFFICIENCY (Ev )0.62 TOTAL REQUIRED OUTDOOR AIR INTAKE FLOW RATE*(Vot)1,344 CFM *USING SYSTEM VENTILATION EFFICIENCY (Ev) AS CALCULATED BY TABLE 6.2.5.2 TOTAL OUTDOOR AIR PROVIDED 1,400 CFM HOOD SCHEDULE PLAN MANUFACTURER TYPE SERVICE CFM ELECTRICAL DUCT MATERIAL FIRE DIMENSIONS REMARKS CODE & MODEL NO.FLA V/Φ/Hz CONN. PROTECTION L W (IN) (IN) (IN) KH-1 GREENHECK - GRRS RES KITCHEN RANGE 500 15.0 120/1/60 8"ø STAINLESS STEEL YES 30'' 19'' NOTE: 1,2,3,4,5 NOTES: 1. RESIDENTIAL STYLE RANGE HOOD WITH INTEGRAL FIRE SUPPRESSION SYSTEM. 4. NFPA 101 - SPECIFICATION COMPLIANT. 2. EXTERNAL WALL MOUNTED FAN.5. INTEGRAL LIGHT WITH LIGHT AND FAN SWITCHES. 3. FINISHED TOP FOR EXPOSED INSTALLATION AND TOP DUCT CONNECTION. The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 5 3 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC SCHEDULES & OUTSIDE AIR CALCULATIONS M703 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O 2015 IMC MINIMUM OUTDOOR AIR REQUIREMENTS PROJECT NAME: ESTES VALLEY COMMUNITY CENTER DATE:2016-10-31 SYSTEM TAG: RTU-3 PROJECT #: 16023 BY: AB CONDITION ALALYZED: HEATING ROOM NAME ROOM NUMBER ZONE TAG OCCUPANCY CATEGORY FLOOR AREA (SF) DESIGN POPULATION (# OF PEOPLE) OA PER PERSON (CFM/PERSON) (Rp) OA/SF (Ra) AIR DISTRIBUTION TYPE ZONE AIR DISTRIBUTION EFFECTIVENESS (Ez) REQUIRED OA TO ZONE (CFM) (Voz) MAXIMUM PRIMARY AIR TO ROOM (CFM) PERCENTAGE OF PRIMARY AIR TO ROOM AT CONDITION ANALYZED PRIMARY AIR TO ROOM AT CONDITION ANALYZED (CFM) PRIMARY OUTDOOR AIR FRACTION (Zpz) ZONE VENT. EFF. (Evz) MENS RR 203 VAV-3-01 TOILET ROOMS - PUBLIC 125 0 0 0 CSCRH 0.8 0 85 65% 55 0.00 1.26 WOMENS RR 204 VAV-3-01 TOILET ROOMS - PUBLIC 128 0 0 0 CSCRH 0.8 0 85 65% 55 0.00 1.26 DESK STAFF 272 VAV-3-01 OFFICE SPACE 112 1 5 0.06 CSCRH 0.8 15 120 65% 78 0.19 1.08 IT 274 VAV-3-01 OFFICE SPACE 119 1 5 0.06 CSCRH 0.8 15 120 65% 78 0.19 1.07 ADMIN 271 VAV-3-01 OFFICE SPACE 479 4 5 0.06 CSCRH 0.8 58 240 65% 156 0.37 0.89 STAIR 120 VAV-3-02 CORRIDORS 135 0 0 0.06 CSCRH 0.8 10 75 65% 49 0.21 1.06 WATER ENTRY 273 VAV-3-02 STORAGE ROOMS 87 0 0 0.12 CSCRH 0.8 13 35 65% 23 0.57 0.69 CONFERENCE 275 VAV-3-02 CONFERENCE/MEETING 271 13 5 0.06 CSCRH 0.8 102 550 65% 358 0.28 0.98 MARKET 277 VAV-3-03 OFFICE SPACE 115 1 5 0.06 CSCRH 0.8 15 110 65% 72 0.21 1.06 ASSISTANT 279 VAV-3-03 OFFICE SPACE 115 1 5 0.06 CSCRH 0.8 15 120 65% 78 0.19 1.07 EXECUTIVE DIRECTOR 281 VAV-3-04 OFFICE SPACE 191 1 5 0.06 CSCRH 0.8 21 320 65% 208 0.10 1.16 HUMAN RESOURCES 283 VAV-3-05 OFFICE SPACE 97 1 5 0.06 CSCRH 0.8 14 100 65% 65 0.21 1.06 FACILITY DIRECTOR 285 VAV-3-05 OFFICE SPACE 105 1 5 0.06 CSCRH 0.8 14 105 65% 68 0.21 1.06 FINANCE 287 VAV-3-05 OFFICE SPACE 170 3 5 0.06 CSCRH 0.8 32 170 65% 111 0.29 0.98 ADMIN 271 VAV-3-06 OFFICE SPACE 422 4 5 0.06 CSCRH 0.8 54 240 65% 156 0.35 0.92 COPY 278 VAV-3-06 OFFICE SPACE 132 1 5 0.06 CSCRH 0.8 16 135 65% 88 0.18 1.08 TEMP 284 VAV-3-06 OFFICE SPACE 58 1 5 0.06 CSCRH 0.8 11 60 65% 39 0.27 0.99 TRACK 264 VAV-3-07 HEALTH CLUB/WEIGHT ROOM 4,696 18 20 0.06 CSCRH 1.0 642 3,675 65% 2,389 0.27 0.99 CARDIO NORTH 261 VAV-3-08 HEALTH CLUB/WEIGHT ROOM 1,940 20 20 0.06 CSCRH 1.0 516 2,030 65% 1,320 0.39 0.87 MP GROUP EX. 262 VAV-3-09 HEALTH CLUB/AEROBICS ROOM 997 6 20 0.06 CSCRH 0.8 225 2,680 65% 1,742 0.13 1.13 STORAGE 263 VAV-3-09 STORAGE ROOMS 56 0 0 0.12 CSCRH 0.8 8 60 65% 39 0.22 1.05 STORAGE 263a VAV-3-09 STORAGE ROOMS 46 0 0 0.12 CSCRH 0.8 7 40 65% 26 0.27 1.00 MP GROUP EX. 124 VAV-3-10 HEALTH CLUB/AEROBICS ROOM 1,581 34 20 0.06 CSCRH 0.8 969 2,560 65% 1,664 0.58 0.68 STRENGTH 123 VAV-3-11&12 HEALTH CLUB/WEIGHT ROOM 3,127 34 20 0.06 CSCRH 0.8 1085 3,400 65% 2,210 0.49 0.77 JR GOLF 121 VAV-3-13 GYM, STADIUM (PLAY AREA) 192 5 0 0.3 CSCRH 0.8 72 205 65% 133 0.54 0.72 HITTING 122 VAV-3-13 HEALTH CLUB/WEIGHT ROOM 211 1 20 0.06 CSCRH 0.8 41 170 65% 111 0.37 0.89 STORAGE 113 VAV-3-14 STORAGE ROOMS 30 0 0 0.12 CSCRH 0.8 5 25 65% 16 0.28 0.99 CLASSROOM 114 VAV-3-14 CLASSROOMS (AGES 9+) 377 14 10 0.12 CSCRH 0.8 232 620 65% 403 0.57 0.69 RECEIVING/STORAGE 115 VAV-3-14 SHIPPING/RECEIVING 418 0 0 0.12 CSCRH 0.8 63 180 65% 117 0.54 0.73 MECH 116 VAV-3-14 MECHANICAL 98 0 0 0 CSCRH 0.8 0 80 65% 52 0.00 1.26 KITCHEN 112 VAV-3-15 KITCHEN (COOKING) 159 2 0 0 CSCRH 0.8 0 150 65% 98 0.00 1.26 LOUNGE 102 VAV-3-16 LOBBIES 1,672 36 5 0.06 CSCRH 0.8 350 1,100 65% 715 0.49 0.77 STAFF 107 VAV-3-17 OFFICE SPACE 233 2 5 0.06 CSCRH 0.8 30 250 65% 163 0.18 1.08 P & R DIRECTOR 108 VAV-3-17 OFFICE SPACE 127 1 5 0.06 CSCRH 0.8 16 135 65% 88 0.18 1.08 MENS RR 110 VAV-3-17 TOILET ROOMS - PUBLIC 55 0 0 0 CSCRH 0.8 0 50 65% 33 0.00 1.26 WOMENS RR 111 VAV-3-17 TOILET ROOMS - PUBLIC 55 0 0 0 CSCRH 0.8 0 50 65% 33 0.00 1.26 GAMES 106 VAV-3-18 GYM, STADIUM (PLAY AREA) 381 8 0 0.3 CSCRH 0.8 143 520 65% 338 0.42 0.84 MENS RR 105 VAV-3-18 TOILET ROOMS - PUBLIC 230 0 0 0 CSCRH 0.8 0 175 65% 114 0.00 1.26 WOMENS RR 104 VAV-3-18 TOILET ROOMS - PUBLIC 241 0 0 0 CSCRH 0.8 0 200 65% 130 0.00 1.26 EMPLOYEE ENTRY 103 VAV-3-18 CORRIDORS 191 0 0 0.06 CSCRH 0.8 14 100 65% 65 0.22 1.04 LOUNGE 102 VAV-3-18 CORRIDORS 150 0 0 0.06 CSCRH 0.8 11 100 65%65 0.17 1.09 COMMUNITY 141 VAV-3-19 MULTIPURPOSE ASSEMBLY 779 40 5 0.06 CSCRH 0.8 308 1,880 65% 1,222 0.25 1.01 COMMUNITY 141 VAV-3-20 MULTIPURPOSE ASSEMBLY 1,132 40 5 0.06 CSCRH 0.8 335 2,560 65% 1,664 0.20 1.06 STORAGE 180 VAV-3-20 STORAGE ROOMS 85 0 0 0.12 CSCRH 0.8 13 40 65% 26 0.49 0.77 COMMUNITY 141 VAV-3-21 MULTIPURPOSE ASSEMBLY 999 40 5 0.06 CSCRH 0.8 325 2,280 65% 1,482 0.22 1.04 KITCHEN 142 VAV-3-22 KITCHEN (COOKING) 522 5 0 0 CSCRH 0.8 0 1,050 65% 683 0.00 1.26 STORAGE 143 VAV-3-22 STORAGE ROOMS 103 0 0 0.12 CSCRH 0.8 15 50 65% 33 0.48 0.79 CARDIO SOUTH 261 VAV-3-23 HEALTH CLUB/WEIGHT ROOM 1,000 10 20 0.06 CSCRH 0.9 289 1,025 65% 666 0.43 0.83 FLOOR AREA SERVED BY SYSTEM (As )24,744 SF ASHRAE 62.1-2013 TABLE 6.2.5.2 POPULATION OF SYSTEM (Ps )348 MAX Zp 0.58 OA REQUIRED PER UNIT AREA FOR SYSTEM (AVG)(Ras )0.06 CFM SYSTEM VENTILATION EFFICIENCY (Ev )0.57 OA REQUIRED PER PERSON FOR SYSTEM AREA (AVG)(Rps )10.21 CFM ASHRAE 62.1-2013 NORMATIVE APPENDIX A: UNCORRECTED OUTDOOR AIR INTAKE (Vou )5,154 CFM AVERAGE OUTDOOR AIR FRACTION (Xs )0.26 DESIGN PRIMARY SUPPLY FAN AIRFLOW (Vps )19,572 CFM SYSTEM VENTILATION EFFICIENCY (Ev )0.68 TOTAL REQUIRED OUTDOOR AIR INTAKE FLOW RATE*(Vot)7,565 CFM *USING SYSTEM VENTILATION EFFICIENCY (Ev) AS CALCULATED BY APPENDIX A TOTAL OUTDOOR AIR PROVIDED 7,600 CFM The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 20 1 6 - 1 0 - 3 1 1 1 : 4 8 : 5 5 C: \ U s e r s \ a b r u e c k \ D o c u m e n t s \ R e v i t \ 1 6 0 2 3 - H V A C - R 1 6 - C e n tr a l _ a b r u e c k @ t h e b a l l a r d g r o u p . c o m . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R PWF AB 9-1-2016 16003 HVAC OUTSIDE AIR CALCULATIONS M704 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O A B C A B L 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K A2 A3 AG AF AA GYM 131 GYM STORAGE 132 EXIT STAIR S10 EMP ENTRY 103 COMMUNITY KITCHEN 142 STORAGE 143 COMMUNITY 141 LOUNGE 102 VEST 101 STOR 113 KITCHEN 112 CLASSROOM 114 RECV & STOR 115 STAIR 120 JR GOLF 121 ELEV 117 MP GROUP EX 124 WOMEN 104 MEN 105 GAMES 106 STAFF 107 P&R DIRECTOR 108 WOMEN 111 MEN 110 NOTE: SEE MAIN LEVEL FOR ZONE THIS AREA 1 1 5 FIRE SPRINKLER ZONES: (APPROX S.F.) FIRE ZONE #1 LOWER LEVEL (24,708 S.F.) FIRE ZONE #2 MAIN LEVEL (27,049 S.F.) FIRE SPRINKLER GENERAL NOTES: 1 NON COMBUSTIBLE CANOPY, NO FIRE SPRINKLER HEADS REQUIRED. PROVIDE CORROSION RESISTANT HANGERS, RODS, ETC. PER SPECIFICATION IN THIS AREA. 2 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 0 : 4 4 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 LOWER LEVEL FIRE PROTECTION PLAN FP101 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/16" = 1'-0" LOWER LEVEL FIRE PROTECTION PLAN EA EB EC ED EE EF E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 2 A B Q 9 101 L P M 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K N A2 A3 AG AF AA NOTE: (E) POOL BUILDING IS NOT CURRENTLY FIRE SPRINKLED AND IS NOT ANTICIPATED TO HAVE FIRE SPRINKLERS PROVIDED 4" FIRE LINE DOWN TO FDC AUDIBLE/VISUAL FIRE ALARM AT 10' MINIMUM ABOVE GRADE 1 1 1 F 6" FIRE ENTRY, SEE DRAWING 2/P402 FOR DETAIL 1 2 2 1 1 5 FIRE SPRINKLER ZONES: (APPROX S.F.) FIRE ZONE #1 LOWER LEVEL (24,708 S.F.) FIRE ZONE #2 MAIN LEVEL (27,049 S.F.) FIRE SPRINKLER GENERAL NOTES: 1 NON COMBUSTIBLE CANOPY, NO FIRE SPRINKLER HEADS REQUIRED. PROVIDE CORROSION RESISTANT HANGERS, RODS, ETC. PER SPECIFICATION IN THIS AREA. 2 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 0 : 5 1 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 MAIN LEVEL FIRE PROTECTION PLAN FP102 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/16" = 1'-0" MAIN LEVEL FIRE PROTECTION PLAN (E)FD (E)LAV (E)WC (E)WC (E)FD(E)FD (E)FD (E)FD (E)UR (E)WC (E)SH (E)FD (E)FD (E)FD (E)SH (E)HB (E)FD (E)LAV (E)SH (E)FD (E)4" (E ) 4 " W (E ) R D L (E ) O D L (E)EWC (E)WC (E)SH (E)LAV (E)FD (E)WC (E)FD (E)2" CW (E)3" W ( E ) 3 " W (E ) R D L (E ) O D L (E)2" ( E) RDL ( E) ODL (E ) 4 " W (E)WCO (E ) 3 " (E ) 8 " (E)RDL (E)ODL (E ) 3 " W (E )3 " W (E)3" RDL AND ODL (E)3" RDL AND ODL (E)5" RDL (E)5" RDL (E ) 3 / 4 " (E ) 8 " (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD EA EB EC ED EE EF E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 (E)SH (E)FD (E)WC (E)SH (E)LAV (E)SH P401 1 (E)RDL UP TO (E)RD W. TEAM LOCKERS A106 9 1 5 7 2 3 9 10 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 5 1 4 88 8 (E)WC 3 8 8 5 3 3 3 3 3 3 4 42 3 1 4 1 4 3 2 FOYER A101 EXIST POOL DECK A109 EXIST LAUNDRY A111 EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST CHEM A115 EXIST NATATORIUM A110 POOL STORAGE A108 M. TEAM LOCKER A107 MECHANICAL A102 CIRC 259 2 1 2 1 REMOVE (E)GAS SERVICE (E)2" GAS RISE REMOVE (E)GAS METER 3 2 1 3 3 14 15 16 16 7 19 19 19 17 20 19 17 18 22 2119 18 17 18 (E)2" CD (E ) 2 " C D (E ) 2 " C D PLUMBING DEMOLITION KEYNOTES: CAP (E) WASTE LINE BELOW FLOOR SLAB. REMOVE OR ABANDON (E) WASTE PIPING. REMOVE (E) PLUMBING FIXTURES AND ALL ASSOCIATED PLUMBING. CAP (E) VENT ABOVE CEILING. CAP (E) WATER PIPING ABOVE CEILING. REMOVE (E) VENT PIPING. REMOVE (E) WATER PIPING. (E) PLUMBING FIXTURE TO REMAIN. ABANDON (E) WATER SERVICE BELOW POOL DECK. REMOVE (E) WATER SERVICE. REMOVE (E) GAS PIPING AND VALVING ON ROOF. CAP (E) GAS ON ROOF. REMOVE (E) GAS PIPING AND VALVING TO MAU. (E) 2" GAS TO BE CAPPED ON WALL FOR RECONNECTION. CAP 8" BACKWASH DRAIN LINE. CAP (E) 5" RDL AND 5" ODL BELOW GRADE. CAP (E) RDL AND ODL PIPING ABOVE CEILING. REMOVE (E) RDL AND ODL PIPING ABOVE CEILING. REMOVE (E) STORM DRAIN BELOW FLOOR/GRADE. REMOVE (E) GCO. REMOVE (E) ODL AND DOWNSPOUT NOZZLE. REMOVE (E) RDL DROP AND OFFSET BELOW FLOOR. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 EA EB EC ED EE EF E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 (E)VTR (E)VTR (E)VTR (E)RD (E)RD (E)OD (E)OD (E)OD (E)RD (E)RD (E)RD (E)OD (E)RD (E)OD (E)RD(E)OD (E)RD (E)OD (E)RD (E)OD (E)RD (E)OD (E)RD (E)OD (E)RD (E)OD (E)VTR (E)RD (E)OD (E)RD (E)OD (E)2"G (E)1 1/2"G (E ) 1 1 / 2 " (E ) 1 1 / 2 " G 13 11 13 12 11 (E)PDU-1 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 3 4 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 PLUMBING DEMOLITION PLANS PD101 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL PLUMBING DEMOLITION PLAN SCALE: 1/16" = 1'-0" ROOF PLUMBING DEMOLITION PLAN F 6" FIRE AND 3" CW SERVICE, SEE CIVIL FOR CONTINUATION 4" GCO (2-WAY) SEE DETAIL 8" WASTE, SEE CIVIL FOR CONTINUATION, I.E. = ±7,557.62' 10 P501 4" GCO (2-WAY) SEE DETAIL 6" WASTE, SEE CIVIL FOR CONTINUATION, I.E. = ±7,543.62' 10 P501 4" FOUNDATION DRAIN, SEE CIVIL FOR CONTINUATION, I.E. = ±7,541.6'4" GCO (2-WAY) 8" RDL, SEE CIVIL FOR CONTINUATION, I.E. = ±7,559.8' (10,858 S.F.) 4" GCO (2-WAY) 6" RDL, SEE CIVIL FOR CONTINUATION, I.E. = ±7,546.0' (5,712 S.F.) 4" GCO (2-WAY) 4" RDL, SEE CIVIL FOR CONTINUATION, I.E. = ±7,546.0' (2,550 S.F.) G COORDINATE NEW GAS LOAD WITH LOCAL GAS COMPANY, SEE GAS LOAD THIS SHEET MAIN LEVEL FINISHED ELEVATION = 7,563.62' LOWER LEVEL FINISHED ELEVATION = 7,548.62' FIRE DEPT. CONNECTION AUDIBLE/VISUAL FIRE ALARM AT 10' ABOVE FINISHED GRADE (MIN.) 4" GW (2)2" VENT 4" WASTE, SEE CIVIL FOR CONTINUATION 4" GCO GREASE INTERCEPTOR 1,000 GALLON, SEE DETAIL 14 P501 1 THRUST BLOCK, SEE DETAIL 1 P501 1 4" GCO (2-WAY) 4" SD, SEE CIVIL FOR CONTINUATION, I.E. = ±7,546.0' (1,806 S.F.) 4" GCO (2-WAY) 4" SD, SEE CIVIL FOR CONTINUATION, I.E. = ±7,546.0' (1,806 S.F.) EXISTING GAS LOAD SCHEDULE: LOAD: 1500.0 MBH 150.0 MBH 150.0 MBH 300.0 MBH 2100.0 MBH INPUT AT S.L., 2.0 PSI GAS REQUIRED, M.C. TO COORDINATE GAS WITH LOCAL GAS COMPANY. APPLIANCE: (E) BOILER (E) MAU (E) MAU (E) CLOTHES WASHER EXISTING TOTAL NEW GAS LOAD SCHEDULE: LOAD: 1500.0 MBH 300.0 MBH 1000.0 MBH 1000.0 MBH 800.0 MBH 320.0 MBH 1000.0 MBH 400.0 MBH 1440.0 MBH 399.0 MBH 399.0 MBH 399.0 MBH 399.0 MBH 399.0 MBH 399.0 MBH 10154.0 MBH INPUT AT S.L., 2.0 PSI GAS REQUIRED, M.C. TO COORDINATE GAS WITH LOCAL GAS COMPANY. APPLIANCE: (E) BOILER (E) CLOTHES WASHER PDU-2 FUTURE PDU-1 RTU-1 RTU-2 RTU-3 MAU-1 POOL BOILER PB-1 (LEISURE) BOILER B-1 BOILER B-2 BOILER B-3 GWH-1 GWH-2 GWH-3 NEW TOTAL PLUMBING KEYNOTES: 1 LOCATE FOUNDATION PENETRATION THRU STEM WALL AT MAX. 1'-8" BELOW ADJACENT FINISHED FLOOR ELEVATION. The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 0 : 5 3 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 PLUMBING SITE PLAN P100 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1" = 30'-0" PLUMBING SITE PLAN DN A B C DN A B L 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K A2 A3 AG AF AA GYM STORAGE 132 EXIT STAIR S10 GYM 131 MP GROUP EX 124 ELEV 117 STAIR 120 P&R DIRECTOR 108 LOUNGE 102 EMP ENTRY 103 COMMUNITY KITCHEN 142 STORAGE 143 COMMUNITY 141 KITCHEN 112 VEST 101 GW 4" GW, SEE P100 FOR CONTINUATION STRENGTH 123 JR GOLF 121 RECV & STOR 115 HITTING 122 STORAGE 118 STRENGTH 123 CLASSROOM 114 STOR 113 WOMEN 111 MEN 110 ELEC 109 STAFF 107 GAMES 106 MEN 105 P402 1 15 15 15 15 2"13 2" 17 4" 16 19 4" WCO 13 2" 2" 4" 14 12 11 SUMP PUMP SP-1, SEE DETAIL 15 P501 F 6" FIRE AND 3" CW SERVICE, SEE P100 FOR CONTINUATION 2" 6 2" WCO 4 7 4 8 3/4" 3/4" 1 1 / 2 " 1" 6" WASTE, SEE P100 FOR CONTINUATION 6" 1" 3/4" 4" 1" 1 1/2" 3/4" L-2 W/ TMV-2 L-2 W/ TMV-2 2" FD-1 W/ TS2" FD-1 W/ TS WC-2 WC-2 5 1 13 3 2 4 P402 3 I.E. = ±7,544.62' 24 4" GCO 3/4" 3/4" 3/4" 4" GCO 24 4" GCO 4" GCO 2 1 / 2 " 1 1 / 4 " 24 4" GCO 24 23 CB-1 6" RDL, SEE P100 FOR CONTINUATION 28 22 26 CB-1 4" RDL, SEE P100 FOR CONTINUATION 6 " 4" GCO 4" GCO24 4" GCO (2-WAY) 8" RDL AND 8" ODL DOWN ON WALL, 8" RDL AND 8" ODL TO (2) 8" DSN AT 18" ABOVE SPLASH BLOCK 24 4" GCO I.E. = ±7,543.25' 4" PERFORATED FOUNDATION DRAIN, SEE P104 FOR CONTINUATION 4" PERFORATED FOUNDATION DRAIN, SEE P104 FOR CONTINUATION 24 SP-1 CONTROL PANEL, COORDINATE LOCATION IN ROOM 28 SEE PLUMBING ISOMETRIC 1 P601 19 4" WCO 16 34 EWC-1 2" WCO 33 30 31 3/4" 2" EWC-1 30 SEE PLUMBING ISOMETRIC 3 P701 2 1 / 2 " 2 1/2" WOMEN 104 4 35 18 4" 36 1" 4" FOUNDATION DRAIN, SEE P100 FOR CONTINUATION 3/4" 7 10 3/4"3/4"3/4" 2" 3/4" WH-1 32 37 IMB-1 38 4 S-2 W/ GDU-1 S-1 2" 4 37 27 4" SD, SEE P100 FOR CONTINUATION (2)2" VENT 27 4" SD, SEE P100 FOR CONTINUATION 4" 21 40 39 39 1 1/2" 2" EWC-1 30 5 4 3" 3" FCO LOWER LEVEL PLUMBING KEYNOTES: 4" WASTE DOWN, 2" VENT RISE, 1" CW TO WC. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. 2" CW, 3/4" HW AND 3/4" HWC DOWN IN WALL AND OFFSET TO FIXTURES. BALL VALVE (FULL SIZE) WITH SERVICE ACCESS. 2" VENT RISE. 2" WASTE STACK RISE AND OFFSET ABOVE CEILING. BALANCING VALVE WITH SERVICE ACCESS (BALANCE TO 1.0 GPM). 2" WASTE, 1/2" HW AND 1/2" CW RISE. 3" VENT RISE. 6" RDL AND 6" ODL RISE. 2" SUMP PUMP DISCHARGE RISE TO FLOOR ABOVE. SP-1 CONTROL WIRING TO CONTROL PANEL. COMBINATION WASTE AND VENT SYSTEM. 2-1/2" CW, 1-1/2" HW AND 1" HWC RISE. 2" WASTE RISE. 4" WASTE AND 2" VENT RISE. 4" WASTE AND 3" WET VENT RISE. 4" WASTE RISE. 4" WASTE STACK RISE AND OFFSET ABOVE CEILING. 3" RDL UP TO 3" RD-1. 4" RDL AND 4" ODL DOWN IN WALL, 4" RDL TO OFFSET BELOW GRADE, 4" ODL TO 4" DSN AT 18" ABOVE CATCH BASIN. 4" RDL UP TO 4" RD-1. 6" RDL AND 6" ODL DOWN IN WALL, 6" RDL TO OFFSET BELOW GRADE, 6" ODL TO 6" DSN AT 18" ABOVE CATCH BASIN. 4" PERFORATED FOUNDATION DRAIN SLOPED AT 1.04%. 3" ODL UP TO 3" OD-1. 4" ODL UP TO 4" OD-1. 4" RDL TO CONNECT TO ARCHITECTURAL GUTTER AND OFFSET INTO COLUMN ENCLOSURE, 4" SD TO OFFSET BELOW GRADE. LOCATE FOUNDATION PENETRATION THRU STEM WALL AT MAX. 1'-8" BELOW ADJACENT FINISHED FLOOR ELEVATION. DISCHARGE GUTTER DOWNSPOUT TO CATCH BASIN AND ROUTE CATCH BASIN 4" PIPING TO RDL. 2" W. DOWN, 1-1/2" V. RISE, 1/2" CW TO EWC. 2" W. STACK. 3/4" CW AND 1/2" HW DOWN IN WALL, 1/2" HW AND 1/2" CW TO SINK, 3/4" CW TO WH. 1/2" CW DOWN. 6" FIRE AND 3" CW SERVICE RISE FOR FLOOR ABOVE. 2" W., 1-1/2" V, AND 1/2" CW RISE. THRUST BLOCK, SEE DETAIL 1/P501. 2" WASTE DOWN, 1-1/2" VENT RISE TO AIR ADMITTANCE VALVE BELOW COUNTER, 1/2" HW AND 1/2" CW TO SINK. 1/2" CW TO IMB. HEAT TRACE TO BE LOCATED IN RD AND PIPING TO 5' OF PIPING BELOW GRADE. SEE P105 FOR CONTINUATION. BALANCING VALVE WITH SERVICE ACCESS, BALANCE TO 0.5 GPM. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 0 : 4 0 : 5 7 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 LOWER LEVEL PLUMBING PLAN P102 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" LOWER LEVEL PLUMBING PLAN A B 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K A2 A3 AG AF AA EXIT STAIR S10 ST. 263 M/P GROUP EX 262 FACILITY DIR 285 FINANCE 287 HR 283 EXEC DIR 281 ASST 279 MARKET 277 CONFERENCE 275 ADMIN 271 LAN 276 COPY 278 ELEC 282 TEMP 284 IT 274 DESK STAFF 272 WOMEN 204 MEN 203 WATER & FIRE ENTRY 273 LOBBY 202 CARDIO 261 11 L-1 W/ TMV-2 3/4" 3/4" 9 15 2" FD-1 W/ TS 2" FD-1 W/ TS 1 1/2" 1 1/2" 11 4" WCO 5 WC-2 WC-2 15 15 2" UR-2 WC-1 12 13 14 9 2-1/2" CW, 1-1/2" HW AND 1" HWC DOWN S-1 25 6 13 16 3" VTR 27 17 27 17 27 17 19 4" OD-1 4" RD-1 (2,550 S.F.) 18 26 18 26 18 26 20 4" GCO I.E.=+/-7,545.0 SEE SHEET P102 FOR CONTINUATION AT LOWER LEVEL 2 1/2" 1" G P402 2 2" 2" 3" 1-1/2" 41 EWC-1 42 44 43 1 1 / 2 " 25 SEE PLUMBING ISOMETRIC 2 P601 SEE PLUMBING ISOMETRIC (SIM.) 2 P601 SEE PLUMBING ISOMETRIC 3 P601 SEE PLUMBING ISOMETRIC 3 P701 ST. 263a CARDIO 261 4" RDL 4" ODL 6" RDL 6" ODL 4" RDL 4" ODL L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 51 51 3/ 4 " 3/ 4 " 3/ 4 " 5 1"3" 2" 52 52C D 3" 1 1/2" 1" 2" GAS RISE 43 6" R D L 6" O D L 8" R D L 8" O D L 8" R D L 8" O D L MAIN LEVEL PLUMBING KEYNOTES: 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. CONNECT 3/4" HW TO (E) HW ABOVE CEILING WITH BALL VALVE AND DOWN IN WALL AND OFFSET TO FIXTURES. 3/4" HW DOWN IN WALL AND OFFSET IN WALL AND CONNECT TO HW AT END LAV. CONNECT 4" WASTE, 2" VENT AND 1" CW TO (E) PLUMBING IN WALL FOR WC. 4" WASTE DOWN, 2" VENT RISE, 1" CW TO WC. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO SINK. 3" VENT UP FROM BELOW. 3" VENT RISE TO 3" VTR. 3/4" HW, 3/4" CW AND 3/4" HWC DOWN IN WALL AND OFFSET TO FIXTURES. CONNECT 3" WASTE TO (E) WASTE BELOW FLOOR. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. 4" WASTE DOWN, 3" WET VENT RISE, 2" VENT RISE, 1" CW TO WC, 3/4" CW TO UR. 2" VENT RISE TO 3" VTR. 2" CW DOWN IN WALL AND OFFSET TO FIXTURES. BALL VALVE (FULL SIZE) WITH SERVICE ACCESS. 2" VENT UP FROM BELOW. 4" RDL UP TO 4" RD-1. 6" RDL UP TO 6" RD-1. 6" RDL AND 6" ODL DOWN IN WALL. 8" RDL AND 8" ODL DOWN ON WALL. 6" RDL DOWN IN WALL AND OFFSET BELOW GRADE. 3/4" CW AND 1/2" HW DOWN IN WALL AND OFFSET BELOW FLOOR. 3/4" CW TO WH-1. COMBINATION WASTE AND VENT SYSTEM. 1-1/2" V. RISE TO 3" VTR. 6" ODL UP TO 6" OD-1. 4" ODL UP TO 4" OD-1. 6" RDL AND 6" ODL DOWN ON WALL, 6" RDL AND 6" ODL TO OFFSET TO 6" DSN AT 18" ABOVE SPLASH BLOCK. 4" PERFORATED FOUNDATION DRAIN SLOPED AT 1.04%. 4" PERFORATED FOUNDATION DRAIN DOWN, SEE P102 FOR CONTINUATION. 3" PLUG VALVE ON HOUSE SIDE OF GAS METER. 3" GAS RISE ON WALL AND OFFSET ON WALL. CONNECT (E) 2" GAS TO (N) 3" GAS LINE. 2-1/2" GAS RISE. 2" G. THRU SIDEWALL ONTO ROOF, SEE DRAWING P102 FOR CONTINUATION. 4" DECK DRAINAGE SLOPED AT 1.04%. LOCATE FOUNDATION PENETRATION THRU STEM WALL AT MAX. 1'-8" BELOW ADJACENT FINISHED FLOOR ELEVATION. COORDINATE POOL FOUNDATION CONNECTION POINT WITH POOL CONTRACTOR. POOL CONTRACTOR WILL PROVIDE BELOW POOL FOUNDATION DRAINAGE AND CONNECT TO THIS LOCATION. 1" CW TO FB-1. 1" CW BELOW POOL DECK. 2" SUMP DISCHARGE RISE AND OFFSET THRU WALL AND AIR GAP TO FLOOR SINK. 1/2" CW UP FROM BELOW TO EWC. 2" W. DOWN, 1-1/2" V. RISE AND 1/2" CW TO EWC. 1-1/2" V. UP FROM BELOW. 2" W. DOWN, 1-1/2" V. RISE TO AIR ADMITTANCE VALVE IN CASEWORK, 1/2" HW AND 1/2" CW TO SINK. SHOCK ABSORBER ABOVE CEILING WITH ACCESS. ARCHITECTURAL DOWNSPOUT TO DISCHARGE ONTO SPLASH BLOCK. CONNECT 4" RDL AND 4" ODL TO (E) ABOVE CEILING. OFFSET 4" ODL THRU WALL TO 4" DSN AS HIGH AS POSSIBLE. 4" RDL DOWN ON WALL AND OFFSET BELOW GRADE. BALANCING VALVE WITH SERVICE ACCESS, BALANCE TO .5 GPM. CONNECT 3/4" CD AND RISE TO ABOVE CEILING, ROUTE DOWN IN WALL AIRGAP TO SINK TAILPIECE. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 0 0 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 MAIN LEVEL PLUMBING PLAN - NORTH P103 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL PLUMBING PLAN - NORTH 2" FD-1 W/ TS (E)RDL (E)ODL (E)3" RDL AND ODL (64 S.F.) (E)3" RDL AND ODL (64 S.F) (E)RDL UP TO (E)RD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)3" W ( E ) 3 " W (E)3" W EA EB EC ED EE EF E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 (E)4" W 4" AD-1 4" FCO 4" FCO 2 Q 9 101 L P M 3 4 6 7 8 N P401 2 P402 4 (E)FD (E)WC (E)WC (E)WC (E)FD (E)FD (E)FD (E)UR WC-1 (E)SH (E)FD (E)FD (E)FD (E)SH (E)HB (E)FD (E)SH (E)RDL (E)ODL (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)SH (E)FD (E)WC (E)LAV 4" AD-1 4" FCO 4" WCO L-1 W/ TMV-2 WC-2 SEE PLUMBING ISOMETRIC 4 P601 1 5 1 4 2 3 ACTIVITY POOL 001 POOL OFFICE 256 W. LOCKERS 221 FAM CHANGING 212 PARTY 211 INDOOR PLAY 205 W. TEAM LOCKERS A106 M. LOCKERS 231 FOYER A101 EXIST POOL DECK A109 W. SHOWERS 222 W. TOILETS 223 M. TOILETS 233 M. SHOWERS 232 JAN 229 ACR2 214 CHG 215 ACR3 216 VESTIBULE 201 EXIST LAUNDRY A111 EXIST POOL MECH A112 EXIST ELEC A113 EXIST POOL EQUIP A114 EXIST NATATORIUM A110 POOL STORAGE A108 M. TEAM LOCKER A107 MECHANICAL A102 POOL STORAGE 255 CIRC 259 OFFICE 206 KIDS T 207 KID WATCH 288 ELEC 254 S-1 ALT WATER SLIDE 002 6 15 36 36 30 18 26 18 26 G G 6" RDL, SEE P100 FOR CONTINUATION 8" WASTE, SEE P100 FOR CONTINUATION 2" FD-1 W/ TS 24 2" 45 28 3/4" WH-1 23 G3" REPLACE (E)GAS SERVICE WITH NEW GAS SERVICE BY LOCAL GAS COMPANY 31 32 33 NEW GAS METER, VALVES, REG, ETC. BY LOCAL GAS COMPANY, SEE GAS LOAD SCHEDULE ON P100. 4" FD-1 W/ TS G G 34 2 1/2" 4" FCO 4" FCO 2929 36 29 4" GCO I.E.=+/-7,545.0 SEE SHEET P102 FOR CONTINUATION AT LOWER LEVEL 1 1 / 2 " 35 G SL O P E W / ST R U C T U R E 24 3" FD-1 W/ TS 24 2" FD-1 W/ TS 36 TRENCH DRAIN (TD-1) 24'-0" TRENCH DRAIN (TD-1) 10'-0" TRENCH DRAIN (TD-1) 4'-0" TRENCH DRAIN (TD-1) 25'-0" 4" 4" TRENCH DRAIN (TD-1) 6'-0" TRENCH DRAIN (TD-1) 8'-0" 36TRENCH DRAIN (TD-1) 40'-0" TRENCH DRAIN (TD-1) 44'-0"36 36 TRENCH DRAIN (TD-1) 56'-0" FB-1 39 40 NOTE: CONNECT 2" DECK DRAINAGE TO TRENCH DRAIN EVERY 20 LF. S-1 3" 2" 36 28 6" R D L 38 22 46 (4,155 S.F) (E)SH 6" O D L NOTE: PROVIDE CORROSION RESISTANT HANGER, ROD AND ACCESSORIES PER SPECIFICATION IN NATARORIUM AND POOL EQUIPMENT ROOM. 6" SD 4" 48 50 49 47 5 L-1 W/ TMV-2 10 I.E. = ±7,562.6' 1/2" 3/4" 3/4" CW AND 1/2" HW UP FROM BELOW FLOOR L-1 W/ TMV-2 2" FD-1 W/ TS 2" FD-1 W/ TS 24 24 ACR1 213 5 1 1 / 2 " 1"3" 2" 25 EWC-1 4" GCO I.E.=+/-7,545.0 4" GCO I.E.=+/-7,545.02" WCO 2" 2" 43 4" FCO MAIN LEVEL PLUMBING KEYNOTES: 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. CONNECT 3/4" HW TO (E) HW ABOVE CEILING WITH BALL VALVE AND DOWN IN WALL AND OFFSET TO FIXTURES. 3/4" HW DOWN IN WALL AND OFFSET IN WALL AND CONNECT TO HW AT END LAV. CONNECT 4" WASTE, 2" VENT AND 1" CW TO (E) PLUMBING IN WALL FOR WC. 4" WASTE DOWN, 2" VENT RISE, 1" CW TO WC. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO SINK. 3" VENT UP FROM BELOW. 3" VENT RISE TO 3" VTR. 3/4" HW, 3/4" CW AND 3/4" HWC DOWN IN WALL AND OFFSET TO FIXTURES. CONNECT 3" WASTE TO (E) WASTE BELOW FLOOR. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. 4" WASTE DOWN, 3" WET VENT RISE, 2" VENT RISE, 1" CW TO WC, 3/4" CW TO UR. 2" VENT RISE TO 3" VTR. 2" CW DOWN IN WALL AND OFFSET TO FIXTURES. BALL VALVE (FULL SIZE) WITH SERVICE ACCESS. 2" VENT UP FROM BELOW. 4" RDL UP TO 4" RD-1. 6" RDL UP TO 6" RD-1. 6" RDL AND 6" ODL DOWN IN WALL. 8" RDL AND 8" ODL DOWN ON WALL. 6" RDL DOWN IN WALL AND OFFSET BELOW GRADE. 3/4" CW AND 1/2" HW DOWN IN WALL AND OFFSET BELOW FLOOR. 3/4" CW TO WH-1. COMBINATION WASTE AND VENT SYSTEM. 1-1/2" V. RISE TO 3" VTR. 6" ODL UP TO 6" OD-1. 4" ODL UP TO 4" OD-1. 6" RDL AND 6" ODL DOWN ON WALL, 6" RDL AND 6" ODL TO OFFSET TO 6" DSN AT 18" ABOVE SPLASH BLOCK. 4" PERFORATED FOUNDATION DRAIN SLOPED AT 1.04%. 4" PERFORATED FOUNDATION DRAIN DOWN, SEE P102 FOR CONTINUATION. 3" PLUG VALVE ON HOUSE SIDE OF GAS METER. 3" GAS RISE ON WALL AND OFFSET ON WALL. CONNECT (E) 2" GAS TO (N) 3" GAS LINE. 2-1/2" GAS RISE. 2" G. THRU SIDEWALL ONTO ROOF, SEE DRAWING P102 FOR CONTINUATION. 4" DECK DRAINAGE SLOPED AT 1.04%. LOCATE FOUNDATION PENETRATION THRU STEM WALL AT MAX. 1'-8" BELOW ADJACENT FINISHED FLOOR ELEVATION. COORDINATE POOL FOUNDATION CONNECTION POINT WITH POOL CONTRACTOR. POOL CONTRACTOR WILL PROVIDE BELOW POOL FOUNDATION DRAINAGE AND CONNECT TO THIS LOCATION. 1" CW TO FB-1. 1" CW BELOW POOL DECK. 2" SUMP DISCHARGE RISE AND OFFSET THRU WALL AND AIR GAP TO FLOOR SINK. 1/2" CW UP FROM BELOW TO EWC. 2" W. DOWN, 1-1/2" V. RISE AND 1/2" CW TO EWC. 1-1/2" V. UP FROM BELOW. 2" W. DOWN, 1-1/2" V. RISE TO AIR ADMITTANCE VALVE IN CASEWORK, 1/2" HW AND 1/2" CW TO SINK. SHOCK ABSORBER ABOVE CEILING WITH ACCESS. ARCHITECTURAL DOWNSPOUT TO DISCHARGE ONTO SPLASH BLOCK. CONNECT 4" RDL AND 4" ODL TO (E) ABOVE CEILING. OFFSET 4" ODL THRU WALL TO 4" DSN AS HIGH AS POSSIBLE. 4" RDL DOWN ON WALL AND OFFSET BELOW GRADE. BALANCING VALVE WITH SERVICE ACCESS, BALANCE TO .5 GPM. CONNECT 3/4" CD AND RISE TO ABOVE CEILING, ROUTE DOWN IN WALL AIRGAP TO SINK TAILPIECE. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 1/8" = 1'-0" 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 0 6 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 MAIN LEVEL PLUMBING PLAN - SOUTH P104 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/8" = 1'-0" MAIN LEVEL PLUMBING PLAN - SOUTH EA EB EC ED EE EF E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 2 A B Q 9 101 L P M 3 4 6 7 A1 A4 AB A5 8 AE AD AH AC C D E F G K N A2 A3 AG AF AA (E)VTR (E)VTR (E)VTR (E)RD (128 S.F.) (E)RD (2,115 S.F.)(E)OD (E)OD (E)OD (E)RD (800 S.F.) (E)RD (2,115 S.F.) (E)RD (672 S.F.) (E)OD (E)RD (1,385 S.F.) (E)OD (E)RD (1,385 S.F.)(E)OD (E)RD (1,385 S.F.)(E)OD (E)RD (950 S.F.) (E)OD (E)RD (950 S.F.) (E)OD (E)RD (950 S.F.) (E)OD (E)RD (450 S.F.) (E)OD (E)VTR (E)RD (64 S.F.) (E)OD (E)RD (64 S.F.) (E)OD 6" OD-1 6" RD-1 (5,040 S.F.) NOTE: SEE P103 FOR ROOF PLUMBING THIS AREA 6" OD-1 6" RD-1 (4,410 S.F.) 6" OD-1 6" RD-1 (4,680 S.F.) 6" OD-1 6" RD-1 (3,100 S.F.) 6" OD-1 6" RD-1 (3,240 S.F.) 4" OD-1 4" RD-1 (1,728 S.F.) RTU-1 4" OD-1 4" RD-1 (2,108 S.F.) 6" OD-1 6" RD-1 (4,216 S.F.) 4" OD-1 4" RD-1 (1,586 S.F.) 3" VTR 4" OD-1 4" RD-1 (1,440 S.F.) 3" VTR 4" OD-1 4" RD-1 (2,686 S.F.) 3" VTR 3" VTR (E)PDU-1 3" VTR 1"1" 1 1/4" 2 1/2" G G G 4 13 5 12 1 2" GAS PRV (TYP.) SEE DETAIL 17 P501 3" VTR 1 1/4"G 6 2 1 1/4"G 6 11 3" VTR 3" VTR 3" VTR MAU-1 3" VTR4" VTR 3" VTR SEE GAS SUPPORT DETAIL 4 P501 1 1 / 4 " G SEE GAS SUPPORT DETAIL 4 P501 7 PDU-2 RTU-2 15 14 1" 3" VTR 16 RTU-3 20 18 19 20 CAP 3/4" GAS WITH GAS COCK 17 20 10 9 10 9 1,806 S.F. 1,806 S.F. REROUTED GAS PRV RELIEF WITH GOOSENECK TO ROOF JUNCTION BOX JUNCTION BOX JUNCTION BOX JUNCTION BOX1,590 S.F.2" 2" CAP 1-1/4" GAS WITH GAS COCK 3" VTR 22 ROOF HYDRANT RH-1 21 5 2" 2" GAS UP FROM BELOW 3" VTR 3" VTR PLUMBING KEYNOTES: GAS PIPING THRU SIDE WALL ONTO ROOF. GAS PRESSURE REGULATING VALVE (PRV) 1000 MBH INPUT AT S.L., 2.O PSI TO 14" WC. GAS PRESSURE REGULATING VALVE (PRV) 600 MBH INPUT AT S.L., 2.O PSI TO 14" WC. 2-1/2" GAS UP FROM BELOW AND OFFSET ON ROOF. CONNECT 1-1/2" GAS TO RTU WITH GAS COCK AND 6" DIRT LEG. CONNECT 2" GAS TO RTU WITH GAS COCK AND 6" DIRT LEG. CONNECT 1-1/2" GAS TO PDU WITH GAS COCK AND 6" DIRT LEG. PDU-1A (ALT #2). 3/4" G. DOWN THRU ROOF. HEAT TRACE, RAYCHEM #GM-X1, 146 L.F. x 10 WATT/L.F. = 1,460 WATTS., 120/60/1. LOCATE IN GUTTER AND DOWN IN DOWNSPOUT. E.C. TO POWER WIRE TO JUNCTION BOX AND P.C. TO WIRE AND INSTALL FROM JUNCTION BOX. CONNECT 4" RDL TO GUTTER AND OFFSET DOWN.. GAS PRESSURE REGULATING VALVE (PRV) 800 MBH INPUT AT S.L., 2.0 PSI TO 14" W.C. GAS PRESSURE REGULATING VALVE (PRV) 320 MBH INPUT AT S.L., 2.0 PSI TO 14" WC. GAS PRESSURE REGULATING VALVE (PRV) 500 MBH INPUT AT S.L., 2.0 PSI TO 14" WC. GAS PRESSURE REGULATING VALVE (PRV) 400 MBH INPUT AT S.L., 2.0 PSI TO 14" WC. 1" G. UP FROM BELOW AND OFFSET ON ROOF. CONNECT 1-1/4" G. TO MAU WITH GAS COCK AND 6" DIRT LEG. HEAT TRACE, RAYCHEM #GM-X1, 20 L.F. x 10 WATT/L.F. = 200 WATTS., 120/60/1. LOCATE IN GUTTER AND DOWN IN DOWNSPOUT. E.C. TO POWER WIRE TO JUNCTION BOX AND P.C. TO WIRE AND INSTALL FROM JUNCTION BOX. HEAT TRACE, RAYCHEM #GM-X1, 35 L.F. x 10 WATT/L.F. = 350 WATTS., 120/60/1. LOCATE IN GUTTER AND DOWN IN DOWNSPOUT. E.C. TO POWER WIRE TO JUNCTION BOX AND P.C. TO WIRE AND INSTALL FROM JUNCTION BOX. HEAT TRACE, RAYCHEM #GM-X1, 40 L.F. x 10 WATT/L.F. = 400 WATTS., 120/60/1. LOCATE IN GUTTER AND DOWN IN DOWNSPOUT. E.C. TO POWER WIRE TO JUNCTION BOX AND P.C. TO WIRE AND INSTALL FROM JUNCTION BOX. ARCHITECTURAL DOWNSPOUT DOWN TO LOWER ROOF / SPLASH BLOCK. 3/4" CW UP TO RH-1. CONNECT (2) 1-1/2" CONDENSATE TO PDU THRU CURB. PDU-1A (ALT #2). (ALT #2) GAS PRESSURE REGULATING VALVE (PRV), 400 MBH INPUT AT S.L., 2.0 PSI TO 14" WC. ROUTE 2" CONDENSATE WITH PDU-2 CONDENSATE ROUTING TO AIRGAP TO 4" FS-1. (ALT #2) CAP (E) CONDENSATE BELOW CEILING. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 EB EC ED EE EF E8 E9 E10 E11 E12 E13 E14 Q 9 10 P 6 7 8 N (E)VTR (E)VTR (E)OD (E)OD (E)RD (800 S.F.) (E)RD (2,115 S.F.) (E)RD (1,385 S.F.)(E)OD (E)RD (950 S.F.) (E)OD (E)RD (950 S.F.) (E)OD (E)RD (950 S.F.) (E)OD (E)RD (450 S.F.) (E)OD (E)VTR 4" OD-1 4" RD-1 (2,108 S.F.) 6" OD-1 6" RD-1 (4,216 S.F.) 3" VTR (E)PDU-1 1" 1" 1 1/4" 2 1/2" G G G 4 13 5 12 1 2" GAS PRV (TYP.) SEE DETAIL 17 P501 3" VTR 3" VTR 3" VTR 3" VTR SEE GAS SUPPORT DETAIL 4 P501 7 PDU-2 RTU-2 1" 20 18 19 20 JUNCTION BOX JUNCTION BOX 1,590 S.F.2" 2" 22 ROOF HYDRANT RH-1 21 PDU-1A 22 24 23 7 ALT #2 3" VTR 25 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 1 2 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 ROOF PLUMBING PLAN P105 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/16" = 1'-0" ROOF PLUMBING PLAN SCALE: 1/16" = 1'-0" ALTERNATE #2 ROOF PLUMBING PLAN PLUMBING KEYNOTES: CONNECT NEW 2" CW TO (E) 2" CW WITH BALL VALVE. CONNECT 8" WASTE / 8" BACKWASH DRAIN TO (E) 8" WASTE BELOW FLOOR. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO SH. 4" WASTE DOWN, 2" VENT RISE, 1" CW TO WC. 2" VENT RISE TO 3" VTR. SHOCK ABSORBER ABOVE CEILING. COMBINATION WASTE AND VENT SYSTEM. CONNECT 4" WASTE TO (E) 4" WASTE. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. CONNECT 1-1/4" CW TO (E) CW AT STRUCTURE. CONNECT 1-1/4" TEPID WATER TO (E) ES/EEW WATER SUPPLY PIPING. 1-1/4" HW AND 1-1/4" CW TO TMV, 1-1/4" TEPID WATER TO ES/EEW. BALL VALVE (FULL SIZE) WITH SERVICE ACCESS. 4" RDL UP TO 4" RD-1. 4" ODL UP TO 4" OD-1. 4" RDL AND 4" ODL DOWN IN WALL, 4" RDL TO OFFSET BELOW GRADE, 4" ODL TO 4" DSN AT 18" ABOVE CATCH BASIN. 8" WASTE DOWN, 4" VENT RISE FOR BACKWASH CATCH BASIN. SEE DETAIL 6/P501. (2)2" PUMP DISCHARGES RISE ON WALL WITH VALVING, CONNECT AND RISE WITH 3" WASTE AND OFFSET AT STRUCTURE WITH 4" WASTE. 4" WASTE DOWN ON WALL AND AIRGAP TO CATCH BASIN. 4" VENT RISE TO 4" VTR. 1-1/2" VENT RISE TO 3" VTR. 2" VENT FROM SUMP PIT AND RISE ON WALL TO 3" VTR. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" CW TO TEST SINK, TEST SINK SUPPLIED BY POOL CONTRACTOR. 3/4" CW DOWN ON WALL TO WH/HB. GAS PRESSURE REGULATING VALVE (PRV), 1440 MBH INPUT AT S.L., 2.0 PSI TO 14" WC. 2" CW DOWN ON WALL TO 2" RP BACKFLOW FOR POOL MAKE-UP AND RISE AND OFFSET AT STRUCTURE. 3/4" HWC DOWN AND CONNECT TO 3/4" HW AT MAXIMUM 2' FROM FAUCET. BALANCING VALVE WITH SERVICE ACCESS, BALANCE TO 1.0 GPM. CONNECT 6" RDL TO (E) 6" RDL AND 6" ODL BELOW GRADE. CONNECT 2" GAS TO POOL BOILER WITH GAS COCK AND 6" DIRT LEG. CONNECT 2" W. TO (E) WASTE BELOW FLOOR. 2" CW MAKE-UP (RP) DOWN AND CONNECT TO POOL AUTO FILLS, SEE AQUATICS DRAWINGS FOR VALVE AND INSTALLATION REQUIREMENTS. 1" CW BELOW POOL DECK, SEE DRAWING P104 FOR CONTINUATION. 1" CW DOWN WITH BALL VALVE AND OFFSET BELOW FLOOR SLAB. 4" W. DOWN, 2" V. RISE FOR FLOOR SINK. 1/2" CW WITH VALVE TO TRAP PRIMER, 1/2" TP TO FLOOR SINK. 1" G. RISE. ROUTE (E) GAS PRV RELIEF THRU ROOF WITH GOOSENECK. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38E4E5E6E7E8E9 2 Q 1 3 4 (E)ES/EEW (E)RDL (E)ODL (E)SINK (E)WCO (E)3/4" (E)2" (E)FD (E)FD (E)FD (E)HB (E)3/4" (E)1-1/2" (E)8" POOL DECK DRAIN (E)LAV (E)RDL (E)ODL (E)TMV (E)PUMP (E)FD (E)STORAGE TANK (E)BOILER (E)AIR SEPERATOR (E)EXPANSION TANK (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD POOL MECH 253 POOL OFFICE 256 1 2 2" 3" 8" 8" WASTE, SEE P104 FOR CONTINUATION POOL STORAGE 255 ELEC 254 EXIST CHEM A115 EXIST POOL EQUIP A114 EXIST ELEC A113 EXIST LAUNDRY A111 16 1514 8" RDL, SEE P104 FOR CONTINUATION CB-1 TMV-3 10 11 13 13 8" L-2 W/ TMV-2 9 4" 4" GUARD CHG 257 GUARDS 258 EXIST POOL MECH A112 SH-2 3 8 4 5 WC-2 6 13 2" FD-1 W/ TS 3"G 3" 7 4" FD-2 W/ TS 4" DROP TO BELOW PIT SEWAGE EJECTOR SE-1 AND SE-2, SEE DETAIL 13 P501 G G 4" FD-2 W/ TS 7 2" 1 1/4" CB-2 4" WCO 17 22 1820 SE-1 AND SE-2 CONTROL PANEL 8" 4" FD-2 W/ TS 7 12 35 23 4" FD-2 W/ TS TMV-4 31 2" W. TO FLOOR DRAIN 2" W. TO FLOOR DRAIN 7 6" 2" FD-1 W/ TS7 3" FD-1 W/ TS 7 3" FD-1 W/ TS7 3" 30 25 2" 4" FD-2 W/ TS 7 32 2" 13 2" 24 13 POOL SINK, PROVIDED BY POOL CONTRACTOR 3/ 4 " 2" 3/4" HB-1 26 26 24 34 3/4" HB-2 33 19 1 1 / 4 " 3" G 37 4" FS-1 W/ TP 36 2" 5 2" 4" SEE PLUMBING ISOMETRIC 5 P601 1 1/4" 3/4" 1/2" 1/2" 3/ 4 " 1/ 2 " 3/4" 1 1/2"8" 2 8" 29 29 6" 8" SD 6" 6" 38 3/4" 28 27 3/4" CW RISE TO RH 13 5 13 1 1/4" 8" 6" 6"6" 4" 4" 13 E4 E5 E6 E7 E8 E9 (E)ES/EEW (E ) R D L (E ) O D L (E)SINK (E)WCO (E)3/4" (E)2" (E)FD (E)FD (E)FD (E)HB (E)3/4" (E ) 1 - 1 / 2 " (E)8" POOL DECK DRAIN (E)LAV (E)2" (E ) R D L (E ) O D L (E)TMV (E)WATER METER (E)PUMP (E)FD (E)STORAGE TANK (E)BOILER (E)AIR SEPERATOR (E)EXPANSION TANK (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD (E)RDL UP TO (E)RD (E)ODL UP TO (E)OD 3 4 2 1 EXIST CHEM A115 EXIST POOL EQUIP A114 EXIST POOL MECH A112 EXIST ELEC A113 EXIST LAUNDRY A111 5 6 7 8 8 9 9 (E)2" CD (E ) 2 " C D PLUMBING DEMOLITION KEYNOTES: CAP (E) WATER LINE FOR RECONNECTION. REMOVE (E) WATER METER AND WATER SERVICE. ABANDON WATER SERVICE BELOW FLOOR. CAP (E) 8" WASTE FOR RECONNECTION. REMOVE (E) 8" WASTE LINE. CAP CW LINE SERVICING (E)ES/EEW. CAP (E) WASTE BELOW FLOOR. CAP (E) BACKWASH DRAIN LINE AND REMOVE DRAIN BOX. CAP (E) 5" RDL AND 5" ODL BELOW FLOOR. REMOVE AND CAP FOR REROUTING (E) GAS PRV RELIEF. 1 2 3 4 5 6 7 8 9 The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 1 4 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 ENLARGED PLUMBING PLANS P401 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/4" = 1'-0"P401 2 ENLARGED POOL MECHANICAL ROOM PLUMBING PLAN SCALE: 1/4" = 1'-0"P401 1 ENLARGED MECHANICAL ROOM DEMOLITION PLUMBING PLAN C PLUMBING KEYNOTES: 3" CW SERVICE ENTRY, SEE DETAIL 16/P501. 4" WASTE DOWN, 2" VENT RISE FOR FLOOR SINK. 3" SUMP PUMP DISCHARGE THRU WALL AND AIRGAP TO F.S. 3" CW RISE AND OFFSET AT STRUCTURE. (3) FIRE SPRINKLER ZONES, SEE FP PLANS FOR ZONE AREAS. 6" FIRE SERVICE ENTRY, SEE DETAIL 2/P501. 4" FIRE LINE RISE, SEE FP PLANS FOR CONTINUATION. 3/4" CW DOWN ON WALL TO 3/4" HB-1. CONNECT 2" WASTE TO (E) WASTE BELOW FLOOR. BALL VALVE (FULL SIZE) WITH SERVICE ACCESS. BALANCING VALVE WITH SERVICE ACCESS (BALANCE TO 2.0 GPM). BALANCING VALVE WITH SERVICE ACCESS (BALANCE TO 1.0 GPM). 2" CW DOWN IN WALL AND OFFSET TO FIXTURES. 4" WASTE DOWN, 2" VENT RISE, 1" CW TO WC. COMBINATION WASTE AND VENT SYSTEM. 3/4" HW, 3/4" CW AND 3/4" HWC DOWN IN WALL AND OFFSET TO FIXTURES. 3" GW DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO 3-COMP. SINK FAUCET/FS. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. 3" VENT RISE TO 3" VTR. 2" WASTE DOWN, 1-1/2" VENT RISE, 3/4" CW TO UR. 6" RDL UP TO 6" RD-1. 6" ODL UP TO 6" OD-1. 4" RDL UP TO 4" RD-1. 4" ODL UP TO 4" OD-1. 1" CW DOWN IN WALL AND OFFSET TO FIXTURES. 1-1/4" CW AND 3/4" HW DOWN IN WALL AND OFFSET TO FIXTURES. GAS PRESSURE REGULATING VALVE (PRV), 399 MBH INPUT AT S.L., 2.0 PSI TO 10" WC. 1-1/4" GAS DOWN AND CONNECT TO GWH/BOILER WITH GAS COCK AND 6" DIRT LEG. 2" CW, 2" HW (140°F), 2" HW (120°F) AND 1-1/4" HWC DOWN TO PP-1 AND TMV-1 MOUNTED ON WALL. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO SHOWER. 4" ODL TO OFFSET TO 4" DSN AS HIGH AS POSSIBLE ABOVE GRADE AND CEILING. 2" VENT RISE TO 3" VTR. 3/4" CW TO HB/WH. 3" W. DOWN, 1-1/2" V. RISE FOR FLOOR DRAIN. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" CW TO DF. 2" CW, 3/4" HW AND 3/4" HWC DOWN IN WALL AND OFFSET TO FIXTURES. 3" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 3/4" CW TO MSB/HB. 2" WASTE DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO LAV/TMV. SHOCK ABSORBER ABOVE CEILING WITH SERVICE ACCESS. CONNECT 4" WASTE TO (E) 4" WASTE. 2" W. DOWN, 1-1/2" V. RISE FOR SUIT MATE. 3/4" CW DOWN IN WALL, 1/2" CW TO DF, 3/4" CW TO HB. (2) 2" VENT RISE AND CONNECT AT 12" ABOVE FINISHED GRADE, 3" VENT RISE. 1/2" HW AND 1/2" CW TO SHOWER. 4" FIRE LINE DOWN TO FDC. U.L. CHECK VALVE WITH AUTO BALL DRIP. CONNECT 3" ODL TO (E) OD AND OFFSET ABOVE CEILING. CONNECT 3" RDL TO (E) RD AND ROUTE ABOVE CEILING AND DROP IN WALL AND OFFSET BELOW GRADE. CONNECT 4" RDL AND 4" ODL TO (E) RD AND OD AND ROUTE ABOVE CEILING AND DROP IN WALL AND OFFSET BELOW GRADE. BALANCING VALVE WITH SERVICE ACCESS, BALANCE TO .5 GPM. 3/4" HWC DOWN IN WALL AND CONNECT TO 1/2" HW WITHIN 2' OF FAUCET. 2" GW DOWN, 1-1/2" VENT RISE, 1/2" HW AND 1/2" CW TO HS/TMV. 4" GW DOWN, 2" VENT RISE FOR FS. 2" PDU CONDENSATE DOWN ON WALL AND AIRGAP TO F.S. CONNECT (2) 1-1/2" CONDENSATE TO PDU. INDIRECT WASTE TO AIRGAP TO FS. 3/4" HW DOWN AND CONNECT TO DISHWASHER. 1" HW AND 1" CW DOWN IN WALL AND OFFSET TO SHOWER. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Q 9 P 7 8 N 7.96.4 FAM CHANGING 212 W. LOCKERS 221 M. LOCKERS 231 W. TOILETS 223 W. SHOWERS 222 M. TOILETS 233 M. SHOWERS 232 JAN 229 CIRC 259 CHG 215 ACR3 216 ACR2 214 ACR1 213 KIDS T 207 OFFICE 206 WC-2 WC-1 WC-1 4" WCO 14 14 3" FD-1 W/ TS 3" FD-1 W/ TS 10 203" FD-1 W/ TS WC-1 WC-1 WC-2 4" WCO 14 18 3" FD-1 W/ TS 2" FD-1 W/ TS DF-1 W/ BF-1 DF-1 W/ BF-1 1010 UR-1 UR-2 UR-1 3" FD-1 W/ TS 10 2" FD-1 W/ TS 10 30 30 30 18 3030 3030 15 15 15 15 15 15 15 15 15 15 3" FD-1 W/ TS 2" FD-1 W/ TS 2" FD-1 W/ TS MSB-1 W/ HB-1 3" FD-1 W/ TS 15 4" WCO 14 WC-2 WC-2 L-2 W/ TMV-2 L-2 W/ TMV-2 WC-2 L-2 W/ TMV-2 4" WCO 10 3" FD-1 W/ TS 2" FD-1 W/ TS 3" FD-1 W/ TS 3" FD-1 W/ TS 3" FD-1 W/ TS 10 MECHANICAL A102 10 10 18 18 20 30 14 18 WC-1 WC-1 WC-1 WC-1 3" FD-1 W/ TS 3" FD-1 W/ TS 3" FD-1 W/ TS 3" FD-1 W/ TS 1414 38 19 14 50 10 10 10 15 15 30 30 38 10 50 50 30 37 14 38 15 15 15 15 21 22 2324 4" O D L 4" R D L 6" O D L 6" R D L 2" B-1 B-2 G 3" FS-1 4" FS-1 G 2" FD-1 W/ TS 2" FD W/ TS 3" FD W/ TS 3/4" HB-1 10 3/4" 3/4" 3/4" L-2 W/ TMV-2 WC-3 1 1/2" 4" WCO32 1 1/2" 1/ 2 " 1/ 2 " 2" 3/4" 3/4" 2" 1" 3/4" 2" 19 3" 1 1/2" 4" SH-2 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 35 3/ 4 " 3/ 4 " 16 40 PP-1 AND TMV-1 MOUNTED ON WALL 29 8 3/4" GWH-1 GWH-2 GWH-3 232 28 27 2" 1" 1" 15 2" 2" 1 1 / 4 " 9 2727 1" 1"27 28 28 GAS WATER HEATERS, SEE DETAIL P501 3" 1 1/2" SH-2 1 1 / 4 " 1 1 / 4 " 6"6"6" 30 35 SH-2 SH-1SH-1SH-1SH-1SH-1 SH-1 1 1 / 2 " 2" 32 2 1 / 2 " 2 1 / 2 " 3/4" 3/4" SH-1 1 1 / 2 " 1/2" 1/2" 3" 1 1/4" 3/4" 10 16 2" 10 36 39 3" FD-1 W/ TS 15 3/4" 38 15 1" 3" 1 1/2" 3/4" 3/4" 3/4" 3" 39 SH-2 39SH-2 3" FD-1 W/ TS 15 3" 3" 15 14 15 3" FD-1 W/ TS 10 2" FD-1 W/ TS 15 13 30 1 1/2" DF-1 SUIT MATE 28 2" FD-1 W/ TS 15 3" FD-1 W/ TS 15 41 35 42 HB-2 3" FD-1 W/ TS 15 15 34 3" FD-1 W/ TS 3" FD-1 W/ TS 15 4" FD-1 W/ TS 2" FD-1 W/ TS 15 2 3" FD-1 W/ TS 15 28 1" 4" WCO 34 3" FD-1 W/ TS 10 1/ 2 " 1/ 2 " SH-1 44 4" AD-1 3/4" HB-2 33 6" 1" 10 3" CW, 1-1/2" HW AND 1" HWC SEE PLUMBING ISOMETRIC 10 P601 SEE PLUMBING ISOMETRIC 5 P602 SEE PLUMBING ISOMETRIC SIM.3 P602 SEE PLUMBING ISOMETRIC 3 P602 SEE PLUMBING ISOMETRIC SIM. 3 P602 SEE PLUMBING ISOMETRIC 4 P602 SEE PLUMBING ISOMETRIC 1 P602 SEE PLUMBING ISOMETRIC 2 P701 SEE PLUMBING ISOMETRIC 7 P602 SEE PLUMBING ISOMETRIC 1 P701 SEE PLUMBING ISOMETRIC 8 P602 SEE PLUMBING ISOMETRIC SIM. 2 P601 SEE PLUMBING ISOMETRIC SIM.6 P602 SEE PLUMBING ISOMETRIC 6 P602 25 3" WCO 4" WCO L-1 W/ TMV-2 3" FD-1 W/ TS 3" FD-1 W/ TS 3" FD-1 W/ TS 1 1/2" 6" 6" 10 3" FD-1 W/ TS 1 1 / 2 " SEE PLUMBING ISOMETRIC 2 P602 34 15 15 15 4" FCO6"6" 1/2"1/2" 3/4"3/4" 1"1"1 1/4"1 1/4" 3/4" 2" 1 1/2" 48 2" 1 1/2" 47 3" ODL 1 1/4" 1 1/4" 1" 1" 3/ 4 " 3/ 4 " 1/ 2 " 1/ 2 " 6" SD 2" 1 1/2"1 1/2" 2" 1 1/4" 1 1/4" 49 6" AT 1.04% 1 1/2" 49 31 51 50 2" FD-1 W/ TS 15 3" FD-1 W/ TS 15 3" 3" FD-1 W/ TS 15 51 51 3" FD W/ TS15 I.E. = ±7,560.9' 51 L-1 W/ TMV-2 50 152" FD-1 W/ TS 50 L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 54 2" CD 1 1/2" CD 55 4" RDL 3" FD W/ TS 15 4" WCO I.E. = ±7,562.3' L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 50 L-1 W/ TMV-2 16 12 50 3" WCO 2" 2" WCO 2" WCO 2" C D 32 58 2" FD-1 W/ TS 15 FOUNDATION WALL PENETRATION B-3 7 8 A2 7.9 WOMEN 104 MEN 105 UR-1 L-1 3" WCO 20 SEE PLUMBING ISOMETRIC 9 P601 18 19 18 3" WCO 6" WASTE, SEE P102 FOR CONTINUATION 3" WASTE, SEE P102 FOR CONTINUATION 3" 10 12 113/ 4 " 1" 1" WC-2 WC-1 WC-1 WC-1 10 13 4" WCO 2 1 / 2 " 1 1 / 4 " 3" FD-1 W/ TS2" FD-1 W/ TS 15 14 14 3/4" 3/4" 3/4" L-1 W/ TMV-2 12 15 3" 1 1/2" 2" SEE PLUMBING ISOMETRIC 7 P601 SEE PLUMBING ISOMETRIC 6 P601 16 18 18 WC-1 SEE PLUMBING ISOMETRIC 8 P601 14 2" 4" 10 13 WC-1 WC-2 14 UR-1 WC-1 4" WCO 1" 2-1/2" 1-1/4" 2" L-1 W/ TMV-2 L-1 W/ TMV-2 L-1 W/ TMV-2 18 L-1 W/ TMV-2 L-1 W/ TMV-2 36 UR-2 AB 87.9 COMMUNITY KITCHEN 142 STORAGE 143 COMMUNITY 1411"1" 3/4" 10 17 3" FS-1 4" FCO 3 " 2" HS-1 W/ TMV-2 1/2" 1/2"1 1/2" 52 2" FD-1 15 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 10 3" 1 1/2" 4" GW, SEE P102 FOR CONTINUATION MSB-1 & HB-1 37 3/4" WH-1 (2) 2" VENT TO GREASE INTERCEPTOR, SEE P102 FOR CONTINUATION 33 43 10 1 1/2" 4" FS-1 3/4" 10 56 57 3253 2" 56 3" WCO S-3 A5 K 3" CW SERVICE AND 2" VENT, SEE P103 FOR CONTINUATION 3 1 4" WCO 3" CW SERVICE, SEE DRAWING P102 FOR CONTINUATION 45 AUDIBLE/VISUAL FIRE ALARM AT 10' ABOVE FINISHED GRADE 6" FIRE, SEE DRAWING P102 FOR CONTINUATION 5 6 46 F 4 2 4" FS-1 IRRIGATION CONTROLLER, COORDINATE LOCATION IN FIELD The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET As indicated 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 2 2 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 ENLARGED PLUMBING PLANS P402 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: 1/4" = 1'-0"P402 4 ENLARGED LOCKER ROOMS PLUMBING PLAN SCALE: 1/4" = 1'-0"P402 1 ENLARGED PLUMBING PLANSCALE: 1/4" = 1'-0"P402 3 ENLARGED ALTERNATE KITCHEN PLUMBING PLAN SCALE: 1/4" = 1'-0"P402 2 ENLARGED MECHANICAL ROOM PLUMBING PLAN ROOF DRAIN INSTALLATION DETAIL 16" 4" 23" 6" 4" 131_ 2" 201_ 2" 6" BACKWASH CATCH BASIN DETAILGAS PRESSURE REGULATING VALVE PIPING DETAIL 6 P501 1 P501 4 P501 2 P501 3 P501 7 P501 8 P501 9 P501 10 P501 14 P501 5 P501 11 P501 12 P501 P501 13 15 P501 16 P501 17 P501 18 P7-01 SCALE: NONE SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE (WATER) SCALE: NONE SCALE: NONE SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE 1000 GALLON CAPACITY SCALE: NONE SCALE: NONE SCALE: NONE (SIDE)SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE THRUST BLOCK SCHEDULE PRV SCHEDULE REQUIRED BEARING AREA (SQ. FT.) PIPE SIZE 90° ELL 45° ELL 22-1/2 ELL TEE OR PLUG PRESS. OUTPRESS. INMANUFACTURERCODE MODEL GPM SIZE FINISHED GRADEFINISHED FLOOR FLOORFLOOR FINISHED GRADEFINISHED GRADE FINISHED FLOOR THRUST BLOCK - CONCRETEGAS PIPING SUPPORT DETAIL FIRE SERVICE ENTRY DETAIL PRESSURE REDUCING STATION DETAIL GAS FIRED WATER HEATER DETAIL CLEANOUT DETAIL (FLOOR) CLEANOUT DETAIL (WALL)CLEANOUT DETAIL (WALL) GRADE CLEANOUT (2-WAY) GREASE INTERCEPTOR DETAIL ROOF DRAIN/DOWNSPOUT DIAGRAMPOOL BACKWASH STANDPIPE DETAIL DUPLEX SEWAGE EJECTOR DETAIL ELEVATOR SUMP PUMP DETAIL DOMESTIC CW ENTRY PIPING DETAIL ROOF/OVERFLOW DRAIN CATCH BASIN DETAIL (TYP.) WCO NO-HUB COUPLING 6" BOTTOM OUTLET UPSIZE TO 8" P-TRAP AND 8" WASTE 24"x24"x24" CATCH BASIN (CB-2) SEE SPECS. AIRGAP BACKWASH DRAIN TO CATCH BASIN. REFER TO AQUATICS 4" 8" 4" VENT LOADS AND PRESSURES, ADJUST AREAS PROPORTIONATELY. THE TABLE NEGLECTS ABOVE TABLE IS BASED ON 1,500 LB/SF BEARING AND 100 P.S.I. FOR OTHER BEARING BEARING AREA PER SCHEDULE-AGAINST UNDISTURBED SOIL CONCRETE THRUST BLOCK CENTRIFUGAL THRUST. NOTE: 6" 8" 4" 2.7 4.7 2.7 1.4 2.6 1.4 0.7 1.3 0.7 1.9 3.4 1.9 BASED ON ROOF AND/OR UNISTRUT PIPE CLAMP A D J U S T A B L E PIPE SLOPE. UNISTRUT (BY M.C.) GAS PIPE ON ROOF, SEE DRAWINGS FOR SIZES GALVANIZED UNISTRUT FRAME AND SUPPORT (BY M.C.) SUPPORT. ADJUSTMENT ADJUSTABLE UNISTRUT GALVANIZED FOR PIPING UP TO 3", 4" AND LARGER SHALL HAVE ROLLERS ADJUSTMENT MIN. 9" FOR RE-ROOFING (12" ABOVE ROOF MIN.) MEMBRANE PAD BY M.C., UNDER SUPPORT HAVE 24"x18" ROOF MEMBRANE ROOF SHALL FOR LAYOUT AND SIZING OF REFERENCE FPC SHOP DRAWINGS (BY E.C.) AND INTERIOR ALARMS, WIRING TO EXTERIOR 2"BACKFLOW PREVENTER DOUBLE CHECK 6" U.L. APPROVED 2" DRAIN VALVE WALL AND TERMINATE WITH 45° EXTEND 2" DRAIN THRU EXTERIOR PRESSURE GAUGE SWITCH WITH EACH 6" FINISHED FLOOR JOINTS AT ELBOW ROD PIPING AND 6" FIRE SERVICECONCRETE THRUST BLOCK FS TO SIAMESE FIRE DEPARTMENT CONNECTION ASSEMBLY 4" U.L. CHECK VALVE WITH AUTOMATIC BALL DRIP ENTRY FLANGE BUILDING FIRE SPRINKLER SYSTEM WATER FLOW SWITCH, 3/4" ELBOW PROVIDE TAMPER O.S.&Y. GATE VALVE U.L. BUTTERFLY VALVE W/ TAMPER SWITCH 6" 75180WATTSPRV-1 LF223S 94 1-1/2" 75180WATTSPRV-2 LF223S 94 1-1/2" PRV-2 PRV-1 BALL VALVE (TYP.) STRAINER (TYP.) UNION (TYP.) PRESSURE GAUGE WITH COCK (TYP.) 3"3" 3" PIPE REDUCER/ INCREASER (TYP.) 2" 2" 2"2" GLOBE VALVE (BRONZE & LEAD-FREE) CHECK VALVE, (TYP.)BALANCING VALVE TIGHT CLOSING THERMOMETER (TYP.) PP-1, SEE SCHEDULE DOMESTIC HOT WATER SEE SCHEDULE GAS FIRED WATER HEATER UNION (TYP.) GAS COCK (TYP.) MIN. 6" DIRT FLUE (TYP.) ASME T&P RELIEF VALVE (TYP.) HOSE END DRAIN VALVE (TYP.) TO FLOOR DRAIN (TYP.). RELIEF VALVE OPENING, AIR GAP RELIEF VALVE DRAIN, FULL SIZE OF (TYP. EACH HW AND CW CONNECTION) BALL VALVE AND DIELECTRIC NIPPLE CONNECT TO WATER HEATER WITH G G G D D D CIRCULATING PUMP PET NOTE: PROVIDE EQUALIZING MANIFOLD OR REVERSE RETURN PIPING. TANK (PET) PLUMBING EXPANSION UNION, (TYP.) 120°F TMV-1 MIXING VALVE BALL VALVE, (TYP.) LEG, (TYP.) FLUE (TYP.) RE: HVAC IS ONLY REQUIRED ON NOTE: VACUUM RELIEF HEATERS NOT PROVIDED WITH DIP TUBES WITH ANTI SYPHON PROTECTION. WATTS #N36-MI VACUUM RELIEF (TYP.) 4" CONCRETE HOUSEKEEPING PAD PLUG (IF END OF LINE) SEE SPECIFICATIONS CLEANOUT PLUG AND BODY, PAD (GRADE C.O.) 18"x18"x6" THICK CONCRETE COVER (GRADE C.O.) HEAVY DUTY CAST IRON TRACTOR PVC 1/8" BEND, FULL MAIN IS OVER 4") REDUCING BRANCH IF PVC WYE (WYE WITH SIZE, 4" MAXIMUM FLOW ADJUSTING COLLAR SEE SPECS. FOR COVER IN FINISHED FLOOR C.I. RISER WALL WALL COVER - SEE SPECS. PLUG WITH WALL FLUSH SHOWN ON DRAWINGS WASTE/SOIL PIPE SIZE AS EXTEND BRONZE CLEANOUT 18 " M A X WALL WALL COVER - SEE SPECS. PLUG WITH WALL FLUSH SHOWN ON DRAWINGS WASTE/SOIL PIPE SIZE AS EXTEND BRONZE CLEANOUT 18 " M A X HEAVY DUTY CAST IRON TRACTOR COVER (GRADE C.O.) 24"x18"x6" THICK CONCRETE PVC CLEANOUT FLOW ADJUSTING PAD (GRADE C.O.) CLEANOUT PLUG AND BODY, SEE SPECS. PVC RISER COLLAR 4" PVC WATER LEVEL BUILDING 4" PVC 2" PVC TO SEALANT W/RAMNECK PRIMER PAINT ENAMEL BASE ASPHALTIC WHERE REQUIRED. CONCRETE RING MIN. 24" DIA. REINF. BLDG. TO VENT 2" PVC THROAT RINGS PRECAST CONCRETE MORTARAND COVER WITH H20 GASTIGHT CAST IRON RING + 2" PIPE O.D. 2. 1. CENTERS WIDTHWAYS, AND NO. 8 REBAR DIAGONALLY AROUND ACCESS HOLES. REINFORCED LONGITUDINALLY WITH NO. 6 REBAR ON 6" CENTERS, NO4 REBAR ON REINFORCED THROUGH OUT WITH 2" x 16", 6/10 REMESH OR HEAVIER. COVERS TO BE ALL CONCRETE TO BE 4000 P.S.I. MIN. STRENGTH TYPE II. WALLS AND BOTTOM TO BE SECONDARY COMPARTMENT TO HAVE VOLUME EQUAL TO 1/3 OF TOTAL CAPACITY. NOTES: 2" VENT IN TOP SLAB INLET OUTLET 4" PVC 4" PVC 60" 12"9"12" 6" 18" ±36" 5'-0" 4'-0" 6" 7'-0" 6"4" 4" PVC 46" 22" 3. ALL PIPE AND FITTINGS TO BE SCHEDULE 40 PVC SOLID CORE. 4. INTERCEPTOR, MANHOLE, AND COVER TO BE H-20 TRAFFIC DUTY RATED. RATING 10" RDL WITH DOWNSPOUT NOZZLE 6" RDL WITH DOWNSPOUT NOZZLE (TYP.) NIPPLE 4" RDL WITH DOWNSPOUT NOZZLE DOWNSPOUT FACE OF WALL EXTERIOR NOZZLE (TYP.) PIPE ELBOW SHORT SWEEP (TYP.) 8" RDL WITH DOWNSPOUT NOZZLE STEP 1: BEFORE INSTALLATION OF ROOF INSULATION STEP 2: AFTER INSTALLATION OF ROOF INSULATION A.) INSTALL THREADED ROD OF LENGTH OF INSULATION DEPTH AND DECK CLAMP CONNECTION (TYP.) B.) SECURE NUT AND FENDER WASHER TO HOLD DRAIN AT PROPOSED INSULATION DEPTH (TYP.) ROOF DECK, CONCRETE & METAL (TYP.) ROOF DRAIN (TYP.) ROOF DRAIN LEADER (TYP.) ROOF INSULATION BY ROOFING CONTRACTOR C.) LOOSEN NUTS AS REQUIRED TO MATCH FIELD HEIGHT OF INSULATION (TYP.) D.) PROVIDE DECK CLAMP AND SECURE INTO PLACE E.) TRIM EXCESS THREADED ROD AS REQUIRED (TYP.) ROOF MEMBRANE BY ROOFING CONTRACTOR INSTALL FLASHING PAN (TYP.) UNISTRUT WITH PIPE CLAMP (TYP.) SIZE PER WASTE/SOIL PIPE, WCO TO WALL (TYP.) 1/2" ROD SECURE 12"∅ 36 " 24 " PER DRAWINGS VENT PIPE, SIZE NO-HUB COUPLING SPECIFICATIONS PVC PER DRAWINGS SCHEDULE (SE-1, SE-2), WITH QUICK REMOVAL REINFORCED FLOOR TYPE II, 4" WALLS, AND 6" 4000 P.S.I. MIN. CONCRETE SUMP, DUPLEX SEWAGE RAIL SYSTEM, SEE EJECTOR PUMP 24 " 7" 4"8" PUMP #1 "OFF" PUMP "ON" 18 " 8" 3" 5' - 0 " PUMP #2 "ON" & DWGS. FOR VENT, SEE SIZE (TYP.) 48" EJECTOR DISCHARGE SWITCH FLOAT BRACKET WALL 4" W. CONTROL WIRING TO CONTROL 2" SEWAGE POWER/ 24"x36" HALLIDAY #HIR2436 H-20 TRAFFIC DUTY BASIN COVER, GAS TIGHT, POWER CONTROL CABLES DISCHARGES COMBINE 2" CHECK VALVE GATE VALVE DISCHARGE (2) 2" PUMP 3" RISE MIN. 24" A.F.F. EQUAL TO DECO #PSC NOTE: APPLY (1) COAT TO INTERIOR WATER-PROOFING PANEL IN CONDUIT PIPING IN SUMP TO BE MADE UP WITH SCHEDULE 40 ±20'-0" DOWN NOTE: STREAM OF PUMP PVC OR DWV COPPER (PRESSURE (FITTINGS) PIPING IN SUMP TO BE MADE UP WITH DWV COPPER NOTE: PUMP (SP-1) SIMPLEX SUMP PUMP ELEVATOR PIT CHECK VALVE GATE VALVE CONCRETE SUMP, OR FIBERGLASS HEAVY DUTY OPEN PIPE AND FITTING PUMP OFF LEVEL PUMP ON LEVEL HIGH WATER ALARM 3" RELAY GFCI HIGH WATER FLOAT MOUNTING BRACKET OIL SMART PUMP SWITCH OIL SMART GFCI ALARM SYSTEM GRATE BY OTHERS IN JANITORS CLOSET ON SUMP BY M.C. 24" DIAMETER 8" 4" 24 " 24" 2" FIRST FLOOR EQUAL TO DECO #PSC NOTE: APPLY (1) COAT TO INTERIOR WATER-PROOFING D 3" CW TO BUILDING FIXTURES AND EQUIPMENT (2) 2" REDUCED PRESSURE BACKFLOW PREVENTER STACKED FOR DOMESTIC COLD WATER (BY P.C.) (TYP.) 12"∅ FUNNEL 3" BALL VALVE FOR SYSTEM SHUT-OFF 3" CW SERVICE FLOOR LINE 2" DRAIN FROM FUNNEL TO AIR GAP TO FLOOR SINK (TYP.) PRESSURE GAUGE WITH COCK 3" STRAINER W/ BLOWDOWN VALVE & PIPED FULLSIZE TO DRAIN (TYP.) FLOOR SINK 2" DRAIN PIPED TO 2" DRAIN VALVE WITH 3" (PARALLEL ARRANGEMENT) 2" CW 3" WATER METER PER WATER DISTRICT REQUIREMENTS TEE FITTING W/MIN.GAS COCK (FULL SIZE) G DOWNSTREAM SIZE 3/4" CAPPED TEE FOR PRESSURE MEASURING EQUIPMENT CONNECTION (TYP. OF 2) UPSTREAM GAS PRESSURE REDUCING VALVE UNION INCREASED/REDUCERS AS CLOSE TO PRV AS POSSIBLE. 3" UNION (TYP.) KEYNOTES: 12"Ø PVC NYOPLAST "IN-LINE" DRAIN. (CATCH BASIN) PVC ROOF DRAIN LEADER. SEE PLUMBING PLANS FOR SIZE, INVERT AND CONTINUATION. SLEEVE THROUGH STEM WALL OR BELOW FOUNDATION PER DRAWINGS. OVERFLOW ROOF DRAIN DOWNSPOUT NOZZLE (DSN). 1 2 3 NOTE : CONTRACTOR TO VERIFY ROOF DRAIN LEADER LOCATION PRIOR TO INSTALLATION OF CATCH BASIN 1 3 FACE OF EXTERIOR WALL 1" MAX RDL ODL W/ DSN CLEANOUT WYE CATCH BASIN 45° SWEEP ELBOW SD MAIN ODL W/ DSN RDL CATCH BASIN WYE CLEANOUT 45° SWEEP ELBOWSD MAIN OFFSET ROOF DRAIN AND OVERFLOW OPTIONS NYLOPLAST GENERAL NOTES : A. GRATES COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. LOCKING DEVICE. B. FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. TYPICAL CATCH BASIN INSTALLATION 8" MIN. GRATE LEVEL WITH CONCRETE 8" CONCRETE COLLAR RDL & ODL W/ DSNCATCH BASIN CLEANOUT 45° FITTING TO RDL BELOW SD MAIN CATCH BASIN 2 ROOF DRAIN LEADER EXTERIOR WALL MIN 18" SLOPE CONCRETE PAN TOWARDS CATCH BASIN (TYP.) 2" THERMOSTATIC 2" 2" 2" 2" 2" 2" 2" 1" HW ALARM 2" 2" 2" 2" 2" 2" PRV STATION, SEE DETAIL 3/P501 FINISHED FLOOR FINISHED FLOOR FINISHED GRADE FINISHED FLOOR FINISHED GRADE FINISHED GRADE FINISHED GRADE FINISHED GRADE FINISHED GRADE FOUNDATION The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 2 2 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 PLUMBING DETAILS P501 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O FD WC EWC 1/2" CW TO EWC 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) LAV W/ TMV 1" CW TO WC, (TYP.) 4" 2" 2" 2" 4" 4" 4" 4" 2" 2" 1 1/2" 1 1 / 2 " 1 1 / 2 " 2" 3/ 4 " 2 1/2" 1 1/4" 2 1/2" 1 1/2" 2" 2" WC LAV W/ TMV FD SHOCK ABSORBER "B" W/ ACCESS PANEL 2" 3/ 4 " CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET LAV W/ TMV 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 3/ 4 " 3/ 4 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 2 "2" 2" 2" 2" 3/4"3/4" 3/4" LAV W/ TMV 3/ 4 " 3/4"3/4" 1/2" CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET WC 4" WCO 2" 2" 2" 2 " 1 1 /2 " 2" 2" 2" 4" 3" 4" 2 " 2" 4" 4" 4"2 " 2"2 " WC WC UR FD FD 3/4" CW TO UR 1" CW TO WC (TYP.) 2 " SHOCK ABSORBER "C" W/ ACCESS PANEL 2" 2" LAV W/ TMV (E)WC WC 4" WCO WC (E ) 4" (E )4 " (E )4 " ( E )3" 4" (E ) 4" 4 " 4" 4" 2" 2 "2" 2 " 2" 2" 3/ 4 " 1 1 / 2 " (E ) 1" 1 " 1 /2 " 1 1 /2 " 1 1 / 2 " 1 1 /2 " 1 1 / 2 " 2" 1" 1 " (E ) 1" (E ) 2" (E )2 " (E ) 2" (E )2 " (E )2 " (E)3/4"(E)3/4" (E)2" 1 1 / 2 " ( E )1 1/2" (E)SHOCK ABSORBER (E )2 " SHOCK ABSORBER "B" W/ ACCESS PANEL 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 3 /4 " 3 /4 " 1" CW TO WC (TYP.) 2 " 2 " 1 1 /2 " 2" 3/ 4 " LAV W/ TMV LAV W/ TMV LAV W/ TMV 2" 2" FD FD CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 2" 2 " 3 " 1 1/2" 3/4" LAV W/ TMV WC SH FD FD 3" 3" 3 " 4 " 6" 6" 4 " 2" 2" 4" 1 1 / 2 " 2" 1 1 / 2 " 3/ 4 " 1/ 2 " SHOCK ABSORBER "A" W/ ACCESS PANEL 1/2" HW & 1/2" CW TO SH 1" CW TO WC 1/2" HW & 1/2" CW TO LAV/TMV 1/ 2 " 1/ 2 " 1/2" 1/2" 1 1/2" 1" 3" 2" FD FOR SH 2" CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 3/ 4 " LAV W/ TMV 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1/2" 1 1/2" 1 1 / 2 " 1 1 /2 " 2" 2" 2" 2" 2" 2" 2 " 3 /4 " 3/ 4 " 3/ 4 " 3/4" 3/4" 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 3/ 4 " LAV W/ TMV LAV W/ TMV 3/4" 1/2"3/4" CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 1" CW TO WC (TYP.) 4" 4 "3" 4" 4" 4" 2" 4" 4 " 4 " 4" 4" 2 " 2" 2" 2" 2" 2" 2" 2" 2 " 2 " 2 " 2 " 3" 1 1/2" FD WC WC WC WC WC WC 4" WCO 2 1 /2 " 1 1 /4 " 1 " 2 " 1 " 3/4" 3/4"3/4" 2" SHOCK ABSORBER "C" W/ ACCESS PANEL 2 " FD 1 1/4" 6" 1" CW TO WC (TYP.) 4" 2" 2" 2" 2" 2" WC WC SHOCK ABSORBER "B" W/ ACCESS PANEL 4" WCO 4 " 4" 4" 2 1/2" 2 1/2" 2" UR 3" WCO 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 3/4" CW TO UR 3" 3" 2" 1 1 / 2 " 1 1/2" 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1/2" 2" 2" 3" 2" 2" 3" 3" 3"3" 3 " 1 1/4" LAV W/ TMV SHOCK ABSORBER "B" W/ ACCESS PANEL 3" WCO UR 1 1 / 2 " 2" UR 1 1/4" LAV W/ TMV LAV W/ TMV CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 3/ 4 " 1 1 / 4 " 3/ 4 " 1/ 2 " 1/ 2 " 1 1 / 2 " 1/ 2 " 2" 3/4"3/4" 3/4" 1" 2"2" 1 1/4" 1" 3/4" CW TO UR 1" CW TO WC (TYP.) 2 " 2" 2" 1 1 / 2 " 2" 2" 2" 2" 4" 2" 4" 4" 4" 4 " 4" 2" 4" WCO 4" WCO FD WC WC WC UR 2" 2" 3" 2" 2" SHOCK ABSORBER "C" W/ ACCESS PANEL 2 " 3" 4" 4" The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 2 7 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 PLUMBING ISOMETRICS P601 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE: NONE PLUMBING ISOMETRIC P601 1 SCALE: NONE PLUMBING ISOMETRIC P601 2 SCALE: NONE PLUMBING ISOMETRIC P601 3 SCALE: NONE PLUMBING ISOMETRIC P601 4 SCALE: NONE PLUMBING ISOMETRIC P601 5 SCALE: NONE PLUMBING ISOMETRIC P601 6 SCALE: NONE PLUMBING ISOMETRIC P601 7 SCALE: NONE PLUMBING ISOMETRIC P601 8 SCALE: NONE PLUMBING ISOMETRIC P601 9 SCALE: NONE PLUMBING ISOMETRIC P601 10 2"2" 2" 2" 2" 1 1/2" 2" 2" 2" 2" 2" 4" 4" 4" 4" FD WC WC 4" WCO SHOCK ABSORBER "B" W/ ACCESS PANEL 1" CW TO WC (TYP.) 4" FD WC 4" WCO SHOCK ABSORBER "C" W/ ACCESS PANEL 1" CW TO WC (TYP.) FD FD WC WC WC WC LAV W/ TMV 4" 4" 4 " 3" 4" 4 " 2" 2" 4" 4" 3" 4" 3" 2 " 2" 3/ 4 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 3/ 4 " 2 " 3/ 4 " 3 "1 1/ 2" 2 " 3" 2" 1 1 / 2 " 1 1 / 2 " 2" 2" 2" 2" 3 /4 " 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 3 " 3 " 2 " 2 " 2 " 2 " LAV W/ TMV 3 /4 " 3/ 4 " 3/ 4 " 4 " CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 1 1 / 2 " 4 " 4 " 2" 4" 4" 4" 2" 3" 3 " 4" 4" 1 1 /2 " 3" 1 1 / 2 " 1/ 2 " 1/ 2 " 1/2"3/4" 3 /4 " 1/ 2 " 1/ 2 " 3 " 3 " 3" 1" 3 /4 " 1 " 1 "3 /4 " 1" SH FD FOR SH FD WC LAV W/ TMV 1/2" HW & 1/2" CW TO LAV/TMV 1" CW TO WC 1/2" HW & 1/2" CW TO SH SHOCK ABSORBER "A" W/ ACCESS PANEL 2" 3/ 4 " CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 2" 4" 2" 1 1/2" 2" 2" 1 1/2" 2" 1 1 / 2 " 2" 3/4"1" 3" 2" 4" 3" 3" 4" 4" 4" 4" 2" 1" 1/ 2 " 3/4" 3/4" 1" WC FD FD FD FD LAV W/ TMV 4" WCO 1/2" HW & 1/2" CW TO LAV/TMV 1" CW TO WC SHOCK ABSORBER "B" W/ ACCESS PANEL 3/ 4 " CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET UR FD 3" 3" 3" 3" 2" 2" 1 1 / 2 " 1 1 /2" 1 1 / 2 " 1 1 / 2 " 2 " 3 " 1" 1" UR 3" WCO SHOCK ABSORBER "A" W/ ACCESS PANEL 3/4" CW TO UR (TYP.)1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 2" 2" 2" 2" 3" 3" 3" 2" SH SH SH SH FD FOR SH FD FOR SH FD FOR SH FD FOR SH 1/2" HW AND 1/2" CW TO SH (TYP.) 1/2"1/2" 3/4"3/4" 1" 1" 1 1/4" 1 1/4" SH 3" 2" 4" 6" 4" 6" 2" 2" 2" 3" 2" 2" 2" 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1/2"1 1/2" 2" 2" 1 1/2" 1 1/2" 3/ 4 " 3/ 4 " 3/4" 3/4" 3/4" FD FD LAV W/ TMV 3" 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) 4" 3/4" 3/4" 3/ 4 " LAV W/ TMV LAV W/ TMV LAV W/ TMV 3/4" 3/4" 1/2" CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET 6" 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 2" 2" 2" 2" 3" 3 " 3" 3" 3" 2" 1 1/2" 1 1 /2 " SH SH SH SH SH FD FOR SH FD FOR SH FD FOR SH FD FOR SH FD FOR SH 1 1 / 2 " 1/2" HW & 1/2" CW TO SH (TYP.) 1 1 /4 " 1 1 /4 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/2" 1/2" 3/4" 3/4" 1"1" 1 1/4" 1 1/4" 2" 3" 2" WCO 3" WCO 2 " The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 3 1 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R Checker Author 10-31-2016 16003 PLUMBING ISOMETRICS P602 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE:P602 1 PLUMBING ISOMETRIC SCALE:P602 2 PLUMBING ISOMETRIC SCALE:P602 3 PLUMBING ISOMETRIC SCALE:P602 4 PLUMBING ISOMETRIC SCALE:P602 5 PLUMBING ISOMETRIC SCALE:P602 6 PLUMBING ISOMETRIC SCALE:P602 7 PLUMBING ISOMETRIC SCALE:P602 8 PLUMBING ISOMETRIC PLUMBING FIXTURE CONNECTION SCHEDULE PIPE SIZE (INCHES, MINIMUM) PLAN FIXTURE WASTE COLD WATER HOT WATER REMARKS CODE TRAP VERT. VENT SUPPLY CONNECTION SUPPLY CONNECTION & ARM DRAIN (MIN.) (MIN.) (ACTUAL) (MIN.)(ACTUAL) WC WATER CLOSET INT. 4" 2" 1" 1" - - UR URINAL INT. 2" 1-1/2" 3/4" 3/4" - - LAV LAVATORY 1-1/2" 2" 1-1/2" 1/2" 3/8" 1/2" 3/8" MIXED HW S SINK 1-1/2" 2" 1-1/2" 1/2" 1/2" 1/2" 1/2" SH SHOWER 2" 2" 1-1/2" 1/2" 1/2" 1/2" 1/2" EWC/DF ELEC. WATER COOLER/DRINKING FOUNT. 1-1/2" 2" 1-1/2" 1/2" 3/8" - - WH/HB WALL HYDRANT - - - 3/4" 3/4" - - ES/EEW EMERGENCY SHOWER/ EYEWASH - - - 1-1/4" - 1-1/4" - TEPID HW MSB MOP SERVICE BASIN 3" 3" 1-1/2" 1/2" 1/2" 1/2" 1/2" WATER HEATER SCHEDULE (GAS-FIRED) PLAN MANUFACTURER STORAGE G.P.H. RECOVERY BTUH INPUT EFF. FLUE TANK SIZE OPER. REMARKS CODE & MODEL NO. GALLONS @ 100' RISE @ SEA LEVEL FACTOR SIZE DIA. HT. WEIGHT GWH-1,2,3 PVI 40-L-130A-GCL 130 699 399,000 97% SEE HVAC 33-3/4" 80-3/4" 3,000 LB NOTES: 1,2,3,4 NOTES: 1. ASME CONSTRUCTION.3. 14" WC GAS PRESSURE MAXIMUM. 2.SET TO 140 °F.4. 120/60/1, CONTROL VOLTAGE. PLUMBING FIXTURE SCHEDULE PLAN DESCRIPTION MANUF. MODEL COLOR FITTINGS MANUF. MODEL COLOR REMARKS CODE FINISH FINISH WC-1 WATER CLOSET AMERICAN 3451.001 WHITE SEAT OLSONITE 95SSCT WHITE NOTES: 2,17 FLOOR MOUNTED - 1.28 GPF AUTO STANDARD FLUSH VALVE SLOAN 8111-1.28 CHROME WC-2 WATER CLOSET (ACCESSIBLE) AMERICAN 3461.001 WHITE SEAT OLSONITE 95SSCT WHITE NOTES: 2,16 FLOOR MOUNTED - 1.28 GPF AUTO STANDARD FLUSH VALVE SLOAN 8111-1.28 CHROME WC-3 WATER CLOSET - PRIMARY AMERICAN 2282.001 WHITE SEAT OLSONITE 126-CC WHITE NOTE: 2 FLOOR MOUNTED - 1.28 GPF STANDARD FLUSH VALVE SLOAN 111-1.28 CHROME UR-1 URINAL AMERICAN 6590.001 WHITE FLUSH VALVE SLOAN 8186-0.125 CHROME NOTES: 2,3,18 WALL HUNG - 0.125 GPF AUTO STANDARD UR-2 URINAL (ACCESSIBLE)AMERICAN 6590.001 WHITE FLUSH VALVE SLOAN 8186-0.125 CHROME NOTES: 2,3,16 WALL HUNG - 0.125 GPF AUTO STANDARD L-1 LAVATORY (ACCESSIBLE) AMERICAN 0497.221 WHITE FAUCET CHICAGO EQ-A11A-41ABCP CHROME NOTES: 1,2,5,6,13,14 UNDERCOUNTER MOUNT - 0.5 GPM AUTO STANDARD L-2 LAVATORY (ACCESSIBLE) AMERICAN 0355.012 WHITE FAUCET CHICAGO EQ-A11A-53ABCP CHROME NOTES: 1,2,4,5,6,13 WALL HUNG - 0.5 GPM AUTO STANDARD S-1 SINK (ACCESSIBLE)ELKAY ELUAD2115-5.5" STAINLESS FAUCET DELTA 2480-DST CHROME NOTES: 1,5,7,12 UNDERCOUNTER MOUNT - 1.5 GPM - MANUAL STEEL LESS SPRAY S-2 SINK (ACCESSIBLE)ELKAY ELUAD2115-5.5" STAINLESS FAUCET DELTA 2480-DST CHROME NOTES: 1,5,7,12 UNDERCOUNTER MOUNT - 1.5 GPM - MANUAL STEEL WITH SPRAY S-3 3-COMP SINK ADVANCE 93-3-54-24-RL 16 GA. FAUCET CHICAGO 640-L12E35-369YAB CHROME NOTE: 20 TABCO S.S. GDU-1 GARBAGE DISPOSAL UNIT IN-SINK-ERATOR BADGER 5 - - -- - NOTE: 11 SH-1 SHOWER BY G.C. - - VALVE BRADLEY 1C-HD-ST-AP-BP (LESS HEAD) CHROME NOTES: 8,12,19 1.5 GPM HEAD MOEN 52716EP15 CHROME SH-2 SHOWER (ACCESSIBLE)BY G.C. - - VALVE WITH BRADLEY 1C-HD-D1-A24-G-DV-ST-AP-BP CHROME NOTES :8,12,19 1.5 GPM DIVERTER (LESS FIXED HEAD) HEAD MOEN 52716EP15 CHROME MSB-1 MOP SERVICE BASIN FIAT MSB2424 MOLDED FAUCET ZURN Z843M1-RC-CS CHROME NOTE: 9 STONE ES/EEW-1 EMERGENCY SHOWER/EMERGENCY EYEWASH HAWS 8317 GALVANIZED LESS BOWL - - - - COMBINATION TOWER UNIT EWC-1 ELECTRIC WATER COOLER (HIGH/LOW) ELKAY EZSTL8WSSK STAINLESS - - - - NOTES: 3,10 W/ BOTTLE FILL STATION (ACCESSIBLE)STEEL DF-1 DRINKING FOUNTAIN (HIGH/LOW) ELKAY EDFP210, STAINLESS - - - - NOTE: 3 W/ BOTTLE FILL STATION (ACCESSIBLE)214 & EMASM STEEL HS-1 HAND SINK ADVANCE 7-PS-75 STAINLESS FAUCET CHICAGO 786-317 CHROME NOTES: 1,4,5,6,13 TABCO STEEL NOTES: 1. 17 GA. P-TRAP, C.P. ANGLE SUPPLIES WITH L.K. STOPS.8.COORDINATE MOUNTING HEIGHTS W/ ARCHITECT. 15. MOUNT ON WALL. COORDINATE BEFORE INSTALLATION. 2.BATTERY OPERATED FLUSH VALVE/FAUCET.9.VACUUM BREAKER, PAIL HOOK, CHECK STOPS. 16. MOUNT AT 17" AFF. 3.PROVIDE FIXTURE CARRIER. COORD. WALL THICKNESS. 10. 1/5 HP, 120/60/1 VOLTAGE.17. MOUNT AT 15" AFF. 4.PROVIDE CONCEALED ARM CARRIER.11. 1/2 HP, 120/60/1 VOLTAGE.18. MOUNT AT 24" AFF. 5.PROVIDE INSULATION KIT FOR SUPPLIES & DRAIN. 12. 1.5 GPM FLOW RESTRICTOR.19. PROVIDE 2" FD-1 FOR SH. 6.GRID DRAIN.13. 0.5 GPM FLOW RESTRICTOR.20. PROVIDE (3) LEVEL OPERATED DRAINS WITH BASKET 7.CHROME CRUMB CUP STRAINER.14. COORD. W/ SOLID SURFACE PUNCH.STRAINERS, STOPS IN FAUCET. PUMP SCHEDULE IMP.ELECTRICAL PLAN MANUFACTURER TYPE SERVICE DIA. GPM HEAD % HP VOLTS PHASE RPM VIBRATION CONTROL WEIGHT REMARKS CODE & MODEL NO. (IN) FT EFF. (BHP) ISOLATION (LBS) PP-1 B&G-55B IN-LINE 120 °F CIRC.- 14.0 39 - 2/5 120 1 3,250 INTEGRAL DDC 13.1 NOTE: 1 SP-1 ZOELLER 940-0007 SUMP ELEVATOR - 50 20 - 1/2 120 1 3,250 INTEGRAL SPCP-1 37 NOTES: 7,8 SE-1 & ZOELLER N4292 SEWAGE POOL DECK - 80 30 - 1/2 120 1 3,250 INTEGRAL SECP-1 93 NOTES: 2,3,4,5,8 SE-2 (DUPLEX) EJECTOR NOTES: 1. MOUNT ON WALL. CONNECTED TO DDC CONTROL, OCCUPIED/UNOCCUPIED. 6. PROVIDE WITH 44 GALLON ACCUMULATOR TANK. 2. PROVIDE (2) 1/2 HP, 120/60/1 CIRCUITS TO PANEL FOR EACH PUMP.7. OIL GUARD PACKAGE, PUMP, ALARM, OIL SWITCH, LIQUID SWITCH. 3. PROVIDE (1) 2 AMP CIRCUIT FOR CONTROL PANEL.8. E.C. TO POWER CONTROL PANEL, P.C. TO WIRE PUMPS. 4. COORDINATE WIRING LENGTHS BEFORE PURCHASE.9. WITH CONTROL PANEL, SKID MOUNTED, 80 PSI OUTLET. 5. PROVIDE MECHANICAL FLOATS, QUICK REMOVAL RAIL SYSTEM, DUPLEX ALARM/CONTROL PANEL, (3) FLOAT SYSTEM. MISCELLANEOUS PLUMBING FIXTURE SCHEDULE PLAN DESCRIPTION MANUFACTURER MODEL FINISH REMARKS CODE FD-1 FLOOR DRAIN SEE SPECS --- FD-2 FLOOR DRAIN SEE SPECS --- AD-1 FLOOR DRAIN SEE SPECS --- CB-1 CATCH BASIN SEE SPECS AND DETAIL 18/P701 --- CB-2 CATCH BASIN ZURN Z-887-GG (24"x24") HDPE NOTE: 13 FS-1 FLOOR SINK SEE SPECS --- RD-1 ROOF DRAIN SEE SPECS --- OD-1 OVERFLOW ROOF DRAIN SEE SPECS --- DSN-1 DOWNSPOUT NOZZLE SEE SPECS --- HB-1 HOSE BIBB SEE SPECS --- HB-2 HOSE BIBB SEE SPECS --- FB-1 FLOOR HYDRANT BOX SEE SPECS --- RH-1 ROOF HYDRANT SEE SPECS --- WH-1 WALL HYDRANT BOX SEE SPECS --- RPBP REDUCED PRESSURE BACKFLOW PREVENTER SEE SPECS --- IMB-1 ICE MAKER BOX SEE SPECS --- PET-1 PLUMBING EXPANSION TANK AMTROL ST-42VC STEEL NOTE: 1 TMV-1 THERMOSTATIC MIXING VALVE POWERS LFSH1434 ROUGH BRASS NOTES: 2,3,12 TMV-2 THERMOSTATIC MIXING VALVE POWERS LFLM-495, -496, 497 ROUGH BRASS NOTES: 4,6,8 TMV-3 & 4 THERMOSTATIC MIXING VALVE POWERS ETV200 ROUGH BRASS NOTES: 5,7 TD-1 TRENCH DRAIN (POOL DECK) ZURN Z880-POG HDPE NOTES: 9,10 NOTES: 1. ASME CONSTRUCTION. 6. INSTALL FULL SIZE PER DRAWINGS.11. STAINLESS STEEL FRAME. 2.SET TO 120 °F. 7. ASSE 1071 RATED VALVE.12. 75 GPM @ 18 PSI LOSS. 3. ASSE 1017 RATED VALVE. 8. SET TO 110 °F.13. CUT FIBERGLASS GRATE TO ALLOW INDIRECT FILTER BACKWASH 4. ASSE 1070 RATED VALVE. 9. PROVIDE SHOP DRAWINGS FOR ARCH/ENGINEER APPROVAL. PIPING FLOW. 5. SET TO 85°F.10. ADA & HEELPROOF GRATE. 2" 2 " 2" 2" 2" 3 " 4" 4" 1 1 / 2 " 1 1 / 2 " 1 1 /2 " 3 /4 " 3 /4 " 1 /2 " 1 /2 " 1/ 2 " 1/ 2 " 1 1/ 2" FD FOR SH FD FOR SH SH SH 1/2" HW & 1/2" CW TO SH (TYP.) 2" WCO 2" 1 1 / 2 " 3/ 4 " 3/ 4 " 3/4" 1 1 / 2 " 3" 4" 4" 3" 2" 2" 2" 1 1 / 2 " LAV W/ TMV FD 1/2" HW & 1/2" CW TO LAV/TMV (TYP.) LAV W/ TMV LAV W/ TMV LAV W/ TMV 3/ 4 " 3/4" 3/4" CONNECT 3/4" HWC TO HW WITHIN 2' OF FAUCET EWC EWC 2" 1 1 / 2 " 2" 2" 1/ 2 " 1/ 2 " 2" 2" WCO 1/2" CW TO EWC (TYP.) 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1 1/2" 2" 2 " The Ballard Group, Inc. Mechanical Consulting Engineers 2525 S. Wadsworth Blvd, Suite 200 Lakewood, CO 80227 (303) 988-4514 SCALE: ISSUE DATE: DRAWN BY: REV'D BY: PROJECT #: 0123456789101112 A B C D E F G H I J O H L S O N L A V O I E C O L L A B O R A T I V E 616 EAST SPEER BOULEVARD DENVER, COLORADO 80203 T: 303.294.9244 F: 303.294.9440 www.olcdesigns.com 0123456789101112 SHEET #: SHEET TITLE: NO. DATE: TITLE/PURPOSE: 6. 5. 4. 3. 2. 1. 7. 8. 9. 10. 11. 12. 10-31-16 PERMIT SET 12" = 1'-0" 10 / 3 1 / 2 0 1 6 1 0 : 4 1 : 3 2 A M C: \ U s e r s \ j b a l l a r d \ D o c u m e n t s \ 1 6 0 2 3 - P L B G - R 1 6 - C e n t r a l _ jb a l l a r d 7 2 M 5 3 . r v t ES T E S V A L L E Y C O M M U N I T Y C E N T E R TRH TRH/JIB 10-31-2016 16003 PLUMBING SCHEDULES P701 66 0 C O M M U N I T Y D R I V E ES T E S P A R K , C O SCALE:P701 1 PLUMBING ISOMETRIC SCALE:P701 2 PLUMBING ISOMETRIC SCALE:P701 3 PLUMBING ISOMETRIC