HomeMy WebLinkAboutPLANS SIgn 420 Steamer Dr 2020-03-0302-03-20
CCL
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 1.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDA
1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Brian P.
Charles L.
1.0 Site Plan
1
1.0
SITE PLAN
SCALE: N.T.S.
AAA
BBB
3294
Alarado Business Park
420 Steamer Dr. Suite 101
Estes Park Health
Estes Park, CO 80517
Rick B.
December 18, 2019
Various wall signs
3294
AAA CHANNEL LETTERS
Quantity (1)
CCC
CHANNEL LETTERS
Quantity (1)
BBB
CHANNEL LETTERS
Quantity (1)
CCC
CHANNEL LETTERS
Quantity (1)
DDD
DDD
CARE
BC0
Shop Drawing for:SD
02-03-20
CCL
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 2.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEA
3294
1
420 Steamer Dr. Suite 101
Estes Park Health
Estes Park, CO 80517
Alarado Business Park
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Rick B.
Charles L.
December 18, 2019
Various wall signs
3294
2.0 Elevations
1
2.0
SOUTH ELEVATION
SCALE: 1/16" = 1'-0"
2
2.0
EAST ELEVATION
SCALE: 1/16" = 1'-0"
NOTE: Verify all dimensions with field survey, prior to fabrication
22'-10"22'-10"22'-10"25'-2"25'-2"25'-2"22'-10"22'-10"22'-10"
2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"1'-5"1'-5"1'-5"
ST-CST-CST-C ST-AST-AST-A ST-BST-BST-BOn estimate #3295On estimate #3295
for Jimmy John'sfor Jimmy John's
On estimate #3295
for Jimmy John's
ST-DST-DST-D
3
2.0
SIGNS ON 3D RENDERING
SCALE: NTS
11'-9 1/2"11'-9 1/2"11'-9 1/2"
Top of "URGENT" will matchTop of "URGENT" will match
PHYSICAL THERAPYPHYSICAL THERAPY
& URGENT CARE on N. Elev.& URGENT CARE on N. Elev.
Top of "URGENT" will match
PHYSICAL THERAPY
& URGENT CARE on N. Elev.
22.43
SQ. FT.
32
SQ. FT.
72.31
SQ. FT.
89.34
SQ. FT.
CARE
B
243.98
SQ. FT. total
C
27.9
SQ. FT.
D0
Shop Drawing for:SD
NOTE: Field verify raceway paint color to building surfacesNOTE: Field verify raceway paint color to building surfacesNOTE: Field verify raceway paint color to building surfaces
3" mounting clips placed as needed on 3" mounting clips placed as needed on
back of racewayback of raceway
3" mounting clips placed as needed on
back of raceway
5'- 0" (2nd Raceway)5'- 0" (2nd Raceway)5'- 0" (2nd Raceway)
C
H
A
N
N
E
L
LE
T
T
E
R
Power InPower InPower In
Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED
.040" Returns.040" Returns.040" Returns
1" Trimcap &1" Trimcap &
Acrylic FaceAcrylic Face
1" Trimcap &
Acrylic Face
LED power supply
Raceway accessRaceway access
SignComp #1976N SignComp #1976N
Raceway access
SignComp #1976N
Bracing bracketsBracing brackets
SignComp #1974N SignComp #1974N
Bracing brackets
SignComp #1974N
3" Raceway large3" Raceway large
mounting clipsmounting clips
SignComp #1988SignComp #1988
3" Raceway large
mounting clips
SignComp #1988
Mounting FastenersMounting Fasteners
as requiredas required
Mounting Fasteners
as required
Extruded RacewayExtruded Raceway
SignComp #1970N SignComp #1970N
Extruded Raceway
SignComp #1970N
¹⁄ " Fastener¹⁄ " Fastener
attachmentsattachments
Letters toLetters to
raceway raceway
¹⁄ " Fastener
attachments
Letters to
raceway
SECTION
N.T.S.
2 P1
5" Narrow5" Narrow
channelchannel
endcapendcap
5" Narrow
channel
endcap
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch
72.31
SQ. FT.
CONSTRUCTION=
MOUNTING=
Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N).
Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia
3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation
Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips.
ACCESS= Removal of Top of raceway
ELECTRICAL
120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave
6'-0" pigtail in seal-tite conduit).
PRIMARY=
12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways
Toggle switch on end of cabinet/raceway.
SECONDARY=
POWER DISCONNECT=
3
02-03-20
CCL
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 3.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDCA
2 1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Brian P.
Charles L.
3.0 EPH Channel Letters
3294
Estes Park Health
Alarado Business Park
420 Steamer Dr. Suite 101
Estes Park, CO 80517
Rick B.
December 18, 2019
Sign Type A
Pan Channel Letters
3294
1
3.0
FRONT ELEVATION
SCALE: 1/2”= 1’-0”
COLOR SPECIFICATIONS
NOTE: Paint all exposed fasteners to match
adjacent finish
1
SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE A
CHANNEL LETTERS
MOUNTING= Mount flush to raceway
TRIMCAP=
LETTER TYPE=
BACKS=
RETURNS=
ILLUMINATION=
1” White Jewelite
Face-Lit pan channel letters
.040" Pre-finished white aluminum
.040" Pre-finished white aluminum (w/ weep holes)
White Sloan Prism Mini LEDs
DEPTH= 4"
FACES= 3/16" White acrylic - #7328 (Digital print graphic on logo face)
2 RACEWAY
20'-0"20'-0"20'-0"
8'-5 3/4"8'-5 3/4"8'-5 3/4"5'-10 3/16"5'-10 3/16"5'-10 3/16"5'-1 1/4"5'-1 1/4"5'-1 1/4"
7'-5 5/8"7'-5 5/8"7'-5 5/8"
1'-3"1'-3"1'-3"
3'-7 3/8"3'-7 3/8"3'-7 3/8"
1
1
DP Digitally printed multicolor gradient graphic on white translucent vinyl
P1 Raceway: P.T.M. Field Verify Mounting Surface
C1 Pantone 7405 - CMYK 3/23/95/0
C2 Pantone 384 - CMYK 29/6/95/26
C3 Pantone 382 - CMYK 50/0/100/0
C4 Pantone 363 - CMYK 80/5/100/30
C5 Pantone 7459 - CMYK 65/12/12/15
BRAND COLORS
P2 Letter Returns: Pre-finished "White"
P21
DP
C1
C2
C3
C4
C5
DP
DP
DP
DP
DP
2
3.0
END VIEW
SCALE: 1/2”= 1’-0”
Power conduit neededPower conduit needed
between racewaysbetween raceways
Power conduit needed
between raceways
2 P1
B
5¹⁄ "5¹⁄ "5¹⁄ "1'-4"1'-4"1'-4"
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch 4"4"4"
3 ¹⁄ "3 ¹⁄ "3 ¹⁄ "
3
3.0
PLAN VIEW
SCALE: 1/2”= 1’-0”
2 P1
11'- 4" (1st Raceway)11'- 4" (1st Raceway)11'- 4" (1st Raceway)
7'- 5" (3rd Raceway beyond)7'- 5" (3rd Raceway beyond)7'- 5" (3rd Raceway beyond)
0
Shop Drawing for:SD
V.I.F.
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 4.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDCA
4 1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Charles L.
4.0 UC North Elev
Channel Letters
3294
Estes Park Health
Estes Park, CO 80517
Alarado Business Park
420 Steamer Dr. Suite 101
Rick B.
December 18, 2019
Sign Type B
Pan Channel Letters
3294
1
4.0
FRONT ELEVATION
SCALE: 1/2”= 1’-0”
COLOR SPECIFICATIONS
NOTE: Paint all exposed fasteners to match
adjacent finish
1
SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE B
CHANNEL LETTERS
MOUNTING= Mount flush to raceway
TRIMCAP=
LETTER TYPE=
BACKS=
RETURNS=
ILLUMINATION=
1” White Jewelite for letters
Face-Lit pan channel letters
.040" Pre-finished white aluminum
.040" Pre-finished white aluminum (w/ weep holes)
White Sloan Prism Mini LEDs
DEPTH= 4"
FACES= 3/16" White acrylic - #7328
4"4"4"
2 RACEWAY
15'-5 5/8"15'-5 5/8"15'-5 5/8"
8'-10"8'-10"8'-10"
1'-6"1'-6"1'-6"
1
P1
P2 Letter Returns: Pre-finished "White"
P21
2
4.0
END VIEW
SCALE: 1/2”= 1’-0”
5'-0"5'-0"5'-0"
3 ¹⁄ "3 ¹⁄ "3 ¹⁄ "
2 P1
5¹⁄ "5¹⁄ "5¹⁄ "
15'- 4 ³⁄ " (Raceway)15'- 4 ³⁄ " (Raceway)15'- 4 ³⁄ " (Raceway)
PLAN VIEW
SCALE: 1/2”= 1’-0”
3" Mounting clips placed as3" Mounting clips placed as
needed on back of racewayneeded on back of raceway
3" Mounting clips placed as
needed on back of raceway
CH
A
N
N
E
L
L
E
T
T
E
R
Power InPower InPower In
Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED
.040" Returns.040" Returns.040" Returns
1" Trimcap &1" Trimcap &
Acrylic FaceAcrylic Face
1" Trimcap &
Acrylic Face
LED power supply
Raceway accessRaceway access
SignComp #1976N SignComp #1976N
Raceway access
SignComp #1976N
Bracing bracketsBracing brackets
SignComp #1974N SignComp #1974N
Bracing brackets
SignComp #1974N
3" Raceway large3" Raceway large
mounting clipsmounting clips
SignComp #1988SignComp #1988
3" Raceway large
mounting clips
SignComp #1988
Mounting FastenersMounting Fasteners
as requiredas required
Mounting Fasteners
as required
Extruded RacewayExtruded Raceway
SignComp #1970N SignComp #1970N
Extruded Raceway
SignComp #1970N
¹⁄ " Fastener¹⁄ " Fastener
attachmentsattachments
Letters toLetters to
raceway raceway
¹⁄ " Fastener
attachments
Letters to
raceway
SECTION
N.T.S.
2 P1
5" Narrow5" Narrow
channelchannel
endcapendcap
5" Narrow
channel
endcap
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch22.43
SQ. FT.
3
4.0
CONSTRUCTION=
MOUNTING=
Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N).
Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia
3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation
Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips.
ACCESS= Removal of Top of raceway
ELECTRICAL
120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave
6'-0" pigtail in seal-tite conduit).
PRIMARY=
12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways
Toggle switch on end of cabinet/raceway.
SECONDARY=
POWER DISCONNECT=
3
B0
Shop Drawing for:SD
CCL
02-03-20
Brian P.
Raceway: P.T.M. Field Verify Mounting Surface
COLOR SPECIFICATIONS
NOTE: Paint all exposed fasteners to match
adjacent finish
1 CHANNEL LETTERS
MOUNTING= Mount flush to raceway
TRIMCAP=
LETTER TYPE=
BACKS=
RETURNS=
ILLUMINATION=
1” White Jewelite for letters
Face-Lit pan channel letters
.040" Pre-finished white aluminum
.040" Pre-finished white aluminum (w/ weep holes)
White Sloan Prism Mini LEDs
DEPTH= 4"
FACES= 3/16" White acrylic - #7328
4"4"4"
2 RACEWAY
P1
P2 Letter Returns: Pre-finished "White"
P21
3 ¹⁄ "3 ¹⁄ "3 ¹⁄ "
5¹⁄ "5¹⁄ "5¹⁄ "
18'- 6 1/2" (Raceway)18'- 6 1/2" (Raceway)18'- 6 1/2" (Raceway)
PLAN VIEW
SCALE: 1/2”= 1’-0”
CH
A
N
N
E
L
L
E
T
T
E
R
Power InPower InPower In
Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED
.040" Returns.040" Returns.040" Returns
1" Trimcap &1" Trimcap &
Acrylic FaceAcrylic Face
1" Trimcap &
Acrylic Face
LED power supply
Raceway accessRaceway access
SignComp #1976N SignComp #1976N
Raceway access
SignComp #1976N
Bracing bracketsBracing brackets
SignComp #1974N SignComp #1974N
Bracing brackets
SignComp #1974N
3" Raceway large3" Raceway large
mounting clipsmounting clips
SignComp #1988SignComp #1988
3" Raceway large
mounting clips
SignComp #1988
Mounting FastenersMounting Fasteners
as requiredas required
Mounting Fasteners
as required
Extruded RacewayExtruded Raceway
SignComp #1970N SignComp #1970N
Extruded Raceway
SignComp #1970N
¹⁄ " Fastener¹⁄ " Fastener
attachmentsattachments
Letters toLetters to
raceway raceway
¹⁄ " Fastener
attachments
Letters to
raceway
SECTION
N.T.S.
5" Narrow5" Narrow
channelchannel
endcapendcap
5" Narrow
channel
endcap
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch27.9
SQ. FT.
CONSTRUCTION=
MOUNTING=
Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N).
Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia
3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation
Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips.
ACCESS= Removal of Top of raceway
ELECTRICAL
120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave
6'-0" pigtail in seal-tite conduit).
PRIMARY=
12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways
Toggle switch on end of cabinet/raceway.
SECONDARY=
POWER DISCONNECT=
3
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 5.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDA
8 1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Charles L.
5.0 RS Channel Letters
3294
Alarado Business Park
Estes Park, CO 80517
Estes Park Health
420 Steamer Dr. Suite 101
Rick B.
December 18, 2019
Pan Channel Letters
Sign Type C
3294
1
5.0
FRONT ELEVATION
SCALE: 1/2”= 1’-0”
2
5.0
END VIEW
SCALE: 1/2”= 1’-0”
B
18'-7 3/16"18'-7 3/16"18'-7 3/16"
7'-4"7'-4"7'-4"
1'-6"1'-6"1'-6"
10'-5 13/16"10'-5 13/16"10'-5 13/16"
3
5.0
SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE C
3" Mounting clips placed as3" Mounting clips placed as
needed on back of racewayneeded on back of raceway
3" Mounting clips placed as
needed on back of raceway
C
2 P1 2 P11
0
Shop Drawing for:SD
02-03-20
CCL
Brian P.
Raceway: P.T.M. Field Verify Mounting Surface
Power conduit neededPower conduit needed
between racewaysbetween raceways
Power conduit needed
between raceways
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 6.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDCA
7 1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Charles L.
6.0 UC East Elev
Channel Letters
3294
Alarado Business Park
Estes Park Health
Estes Park, CO 80517
420 Steamer Dr. Suite 101
Rick B.
December 18, 2019
Pan Channel Letters
Sign Type D
3294
1
6.0
FRONT ELEVATION
SCALE: 1/2”= 1’-0”
SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE D
1'-6"1'-6"1'-6"
CARE P21
2
6.0
END VIEW
SCALE: 1/2”= 1’-0”
8'-10"8'-10"8'-10"
1'-6"1'-6"1'-6"
5'-0"5'-0"5'-0"
1
2 P13'-7 3/8"3'-7 3/8"3'-7 3/8"
B
COLOR SPECIFICATIONS
NOTE: Paint all exposed fasteners to match
adjacent finish
1 CHANNEL LETTERS
MOUNTING= Mount flush to raceway
TRIMCAP=
LETTER TYPE=
BACKS=
RETURNS=
ILLUMINATION=
1” White Jewelite for letters
Face-Lit pan channel letters
.040" Pre-finished white aluminum
.040" Pre-finished white aluminum (w/ weep holes)
White Sloan Prism Mini LEDs
DEPTH= 4"
FACES= 3/16" White acrylic - #7328
2 RACEWAY
P1
P2 Letter Returns: Pre-finished "White"
5¹⁄ "5¹⁄ "5¹⁄ "
8'- 10" (Raceway)8'- 10" (Raceway)8'- 10" (Raceway)
PLAN VIEW
SCALE: 1/2”= 1’-0”
3" Mounting clips placed as3" Mounting clips placed as
needed on back of racewayneeded on back of raceway
3" Mounting clips placed as
needed on back of raceway
CH
A
N
N
E
L
L
E
T
T
E
R
Power InPower InPower In
Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED
.040" Returns.040" Returns.040" Returns
1" Trimcap &1" Trimcap &
Acrylic FaceAcrylic Face
1" Trimcap &
Acrylic Face
LED power supply
Raceway accessRaceway access
SignComp #1976N SignComp #1976N
Raceway access
SignComp #1976N
Bracing bracketsBracing brackets
SignComp #1974N SignComp #1974N
Bracing brackets
SignComp #1974N
3" Raceway large3" Raceway large
mounting clipsmounting clips
SignComp #1988SignComp #1988
3" Raceway large
mounting clips
SignComp #1988
Mounting FastenersMounting Fasteners
as requiredas required
Mounting Fasteners
as required
Extruded RacewayExtruded Raceway
SignComp #1970N SignComp #1970N
Extruded Raceway
SignComp #1970N
¹⁄ " Fastener¹⁄ " Fastener
attachmentsattachments
Letters toLetters to
raceway raceway
¹⁄ " Fastener
attachments
Letters to
raceway
SECTION
N.T.S.
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch 4"4"4"
3 ¹⁄ "3 ¹⁄ "3 ¹⁄ "
5" Narrow5" Narrow
channelchannel
endcapendcap
5" Narrow
channel
endcap
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch32
SQ. FT.
CONSTRUCTION=
MOUNTING=
Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N).
Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia
3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation
Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips.
ACCESS= Removal of Top of raceway
ELECTRICAL
120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave
6'-0" pigtail in seal-tite conduit).
PRIMARY=
12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways
Toggle switch on end of cabinet/raceway.
SECONDARY=
POWER DISCONNECT=
3
3
6.0
2 P1
5'- 8" (2nd Raceway)5'- 8" (2nd Raceway)5'- 8" (2nd Raceway)
02-03-20
CCL
Brian P.
0
Shop Drawing for:SD
Raceway: P.T.M. Field Verify Mounting Surface
TAK
02-18-20
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 1.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 2
Revision Notes:
2
3 TBD
GFEDA
1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Brian P.
Charles L.
1.0 Site Plan
1
1.0
SITE PLAN
SCALE: N.T.S.
AAA
3295
Rick B.
December 19, 2019
Channel Letter wall
sign
3295
AAA CHANNEL LETTERS
Quantity (1)Estes Park, CO 80517
Alarado Business Park
Jimmy John's
420 Steamer Dr. Suite 100
BC
BBB DRIVE THRU DIRECTIONAL
Quantity (1)
CCC EXIT ONLY DIRECTIONAL
Quantity (1)
BBB CCC
0
Shop Drawing for:SD
1 1
02-03-20
CCL
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 2.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEA
3295
1
Alarado Business Park
Estes Park, CO 80517
420 Steamer Dr. Suite 100
Jimmy John's
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Brian P.
Rick B.
Charles L.
December 19, 2019
Channel Letters Wall
Sign
3295
2.0 Elevations
1
2.0
SOUTH ELEVATION
SCALE: 1/16" = 1'-0"
URGENT CARE
NOTE: Verify all dimensions with field survey, prior to fabrication
22'-10"22'-10"22'-10"25'-2"25'-2"25'-2"22'-10"22'-10"22'-10"
On estimate #3294On estimate #3294
for Estes Park Healthfor Estes Park Health
On estimate #3294
for Estes Park HealthST-EST-EST-E
2
2.0
SIGNS ON 3D RENDERING
SCALE: NTS
15'-8³⁄ "15'-8³⁄ "15'-8³⁄ "
On estimate #3294On estimate #3294
for Estes Park Healthfor Estes Park Health
On estimate #3294
for Estes Park Health
On estimate #3294On estimate #3294
for Estes Park Healthfor Estes Park Health
On estimate #3294
for Estes Park Health
38'-0"38'-0"38'-0"
B
89.34
SQ. FT.
CD
Field Verify color matchField Verify color match
to building for raceway paintto building for raceway paint
Field Verify color match
to building for raceway paint
0
Shop Drawing for:SD
CCL
02-03-20
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
AB
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc.Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Prototype Seg. No.0 PT#
Sheet No. 3.0
Rev. No.
Dot No.
W.O. No.
By:
Date:AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
Revision Notes:
2
3 TBD
GFEDA
2,3 1
Design Proposal for:DP
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
Brian P.
Charles L.
3.0 JJ Channel Letters
3295
Rick B.
December 18, 2019
Pan Channel Letters
Sign Type E
3295
1
3.0
FRONT ELEVATION
SCALE: 1/2”= 1’-0”
COLOR SPECIFICATIONS
1
SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN
CHANNEL LETTERS
MOUNTING= Mount flush to raceway
TRIMCAP=
LETTER TYPE=
BACKS=
RETURNS=
ILLUMINATION=
1” Black Jewelite for letters
Face-Lit pan channel letters
.040" Pre-finished White aluminum
.040" Pre-finished Black aluminum (w/ weep holes)
White Sloan Prism Mini LEDs
DEPTH= 5"
FACES= 3/16" White acrylic - #7328 & Vinyl overlay ( logo on disc/drive thru, & a 7/8" border on letter edges)
2 RACEWAY
CONSTRUCTION=
MOUNTING=
Sign Comp 5" (1 piece) narrow channel raceway extruded raceway (#1970N), internal brace (#1974N).
Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia
3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation
Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips.
ACCESS= Hinged lid top or bottom of raceway
ELECTRICAL
120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave
6'-0" pigtail in seal-tite conduit). J-Box TBD
PRIMARY=
12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways
Toggle switch on end of cabinet/raceway.
SECONDARY=
POWER DISCONNECT=
3
V1
P1 Raceway: Field Verify color match for raceway paint
Pantone 186c - 3M 3630-83 "Red"
3M 3630-22 "Black"
Jimmy John's
420 Steamer Dr. Suite 100
Alarado Business Park
Estes Park, CO 80517
3
3.0
PLAN VIEW
SCALE: 1/2”= 1’-0”
V2
P2 Returns: Pre-finished "Black"
2
3.0
END VIEW
SCALE: 1/2”= 1’-0”
B
5"5"5"
3 ¹⁄ "3 ¹⁄ "3 ¹⁄ "
(2)Raceways(2)Raceways
w/ 5" Narroww/ 5" Narrow
channelchannel
endcapendcap
(2)Raceways
w/ 5" Narrow
channel
endcap
2 P1
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch
22'- 5" (Raceway)22'- 5" (Raceway)22'- 5" (Raceway)
C
2'
-
1
0
"
2'
-
1
0
"
2'
-
1
0
"
2'- 10"2'- 10"2'- 10"9'- 2"9'- 2"9'- 2"9'- 5¹⁄ "9'- 5¹⁄ "9'- 5¹⁄ "
5¹⁄ "5¹⁄ "5¹⁄ "
1'- 8³⁄ "1'- 8³⁄ "1'- 8³⁄ "
22'- 11"22'- 11"22'- 11"
On/OffOn/Off
ToggleToggle
switchswitch
On/Off
Toggle
switch
2 P1
1 V2 V1
3" Flange attachment points placed as3" Flange attachment points placed as
needed on back of racewayneeded on back of raceway
3" Flange attachment points placed as
needed on back of raceway
2 P1
89.34
SQ. FT.
C
H
A
N
N
E
L
L
E
T
T
E
R
Power InPower InPower In
Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED
.040" Returns.040" Returns.040" Returns
1" Trimcap &1" Trimcap &
Acrylic FaceAcrylic Face
1" Trimcap &
Acrylic Face
LED power supply
Raceway accessRaceway access
SignComp #1976N SignComp #1976N
Raceway access
SignComp #1976N
Bracing bracketsBracing brackets
SignComp #1974N SignComp #1974N
Bracing brackets
SignComp #1974N
3" Raceway large3" Raceway large
mounting clipsmounting clips
SignComp #1988SignComp #1988
3" Raceway large
mounting clips
SignComp #1988
Mounting FastenersMounting Fasteners
as requiredas required
Mounting Fasteners
as required
Extruded RacewayExtruded Raceway
SignComp #1970N SignComp #1970N
Extruded Raceway
SignComp #1970N
¹⁄ " Fastener¹⁄ " Fastener
attachmentsattachments
Letters toLetters to
raceway raceway
¹⁄ " Fastener
attachments
Letters to
raceway
SECTION
N.T.S.
12'- 4" (2nd Raceway- beyond)12'- 4" (2nd Raceway- beyond)12'- 4" (2nd Raceway- beyond)
On/Off toggle switchOn/Off toggle switchOn/Off toggle switch
1'- 1⁵⁄ "1'- 1⁵⁄ "1'- 1⁵⁄ "
12'- 5¹⁄ "12'- 5¹⁄ "12'- 5¹⁄ "
1 V2
(2) Sign Comp(2) Sign Comp
5" One Piece 5" One Piece
narrow raceways narrow raceways
(2) Sign Comp
5" One Piece
narrow raceways
1 V2
1 P2
J-BoxJ-Box
locationlocation
TBDTBD
J-Box
location
TBD
Bottom racewayBottom raceway
lid side down tolid side down to
run conduitrun conduit
between wherebetween where
neededneeded
Bottom raceway
lid side down to
run conduit
between where
needed
NOTE: Paint all exposed fasteners to match
adjacent finish
0
Shop Drawing for:SD
Raceway to be built in two piecesRaceway to be built in two piecesRaceway to be built in two pieces
Prototype Seg. No.0 PT#
AB
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
Sheet No.
Rev. No.
Dot No.
W.O. No.
By:
Date:
Revision Notes:
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc. Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
02-03-20
CCL
4.0
AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
2
3 TBD
GFEDCA
3295
4 1
Design Proposal for:DP
Brian P.
1
4.0
FRONT ELEVATION
SCALE: 1 1/2”= 1’-0”
2
4.0
END VIEW
SCALE: 1 1/2”= 1’-0”
1'
-
4
"
1'
-
4
"
1'
-
4
"
3'- 2"3'- 2"3'- 2"
1 P1
4.22
SQ. FT.
NOTE: Paint all exposed fasteners to match adjacent finish
1
2
3
SPECIFICATIONS FOR (1) S/F ILLUMINATED DIRECTIONAL SIGN
SIGN CABINET= 1” alum. sq. tube frame with 1/8” alum. returns
GRAPHICS= First surface vinyl overlay
MOUNTING= Sign cabinet is internally attached to a 3” schedule 40 steel
pipe (3 1/2” actual O.D.) with caisson
0’-8"0’-8"0’-8"
3 P1
3'-0"3'-0"3'-0"
hardware
3/8" Inset
1'-0"1'-0"1'-0"
1'-0"
Diameter
Concrete
caisson
Steel pipe
Steel angle-
weld to pipe
Cabinet
frame typ.
P1 P.T.M. MP “Black” (Satin)
1'
-
8
"
1'
-
8
"
1'
-
8
"
3'
-
0
"
3'
-
0
"
3'
-
0
"
3” Schedule 40 steel pipe3” Schedule 40 steel pipe
(0’-3 ¹⁄ " actual O.D.)(0’-3 ¹⁄ " actual O.D.)
3” Schedule 40 steel pipe
(0’-3 ¹⁄ " actual O.D.)
Charles L.
4.0 JJ Drive Thru
Directional
Rick B.
January 13, 2019
Sign Type F
Drive Thru Directional
3295
Alarado Business Park
Jimmy John's
420 Steamer Dr. Suite 100
Estes Park, CO 80517
V1
3
4.0
END SECTION
SCALE: 1 1/2”= 1’-0”
B
COLORS AND FINISHES
V1 3M Vinyl #3630-83 "Red" (Pantone 186C)
3M Vinyl #3630-22 "Black" (reverse weed & opaque)V2
1a SIGN FACE= 3/16" White acrylic w/ 1" Black trimcap
2 1a V22
0
Shop Drawing for:SD
Prototype Seg. No.0 PT#
AB
DateProduction Mgr. Approval
DateProject Mgr. Approval
DateAccount Mgr. Approval
DateP&D Mgr. Approval
Sheet No.
Rev. No.
Dot No.
W.O. No.
By:
Date:
Revision Notes:
Client Approval
NOTE: Please ensure all red line changes are noted on
this drawing prior to returning it to ADCON. Subsequent to
ADCON incorporating the red line changes requested on
this drawing, any further changes will result in additional
billing at the rate of $86 per hour.
Approved As Noted
Revise And Resubmit
Approved
Signature
Date
Advertising Concepts Inc.
3725 Canal Drive,
Fort Collins, CO 80524
970 484 3637
www.adconsigns.com
These documents and plans have been created by and
are the exclusive intellectual property of Adcon Inc. Any
unauthorized use, disclosure, dissemination or dupli-
cation of any of the information contained herein may
result in liability under applicable laws.
Drawn by:
Account Manager:
Project Manager:
Date:
Sign Type:
Design/ Quote #:
File Name:
CCL
02-03-20
5.0
AB
AB
12
12
11
11
10
10
9
9
8 8776
6
5
5
4
4
3
3
2 211
2
3 TBD
GFEDCA
3295
4 1
Design Proposal for:DP
Brian P.
1
5.0
FRONT ELEVATION
SCALE: 1 1/2”= 1’-0”
2
5.0
END VIEW
SCALE: 1 1/2”= 1’-0”
1'
-
4
"
1'
-
4
"
1'
-
4
"
3'- 2"3'- 2"3'- 2"4.22
SQ. FT.
0’-8"0’-8"0’-8"
3 P1
3'-0"3'-0"3'-0"
3/8" Inset
hardware
1'-0"1'-0"1'-0"
1'-0"
Diameter
Concrete
caisson
Steel pipe
Steel angle-
weld to pipe
Cabinet
frame typ.
1'
-
8
"
1'
-
8
"
1'
-
8
"
3'
-
0
"
3'
-
0
"
3'
-
0
"
3” Schedule 40 steel pipe3” Schedule 40 steel pipe
(0’-3 ¹⁄ " actual O.D.)(0’-3 ¹⁄ " actual O.D.)
3” Schedule 40 steel pipe
(0’-3 ¹⁄ " actual O.D.)
Charles L.
5.0 JJ Exit Only
Directional
Rick B.
January 13, 2019
Sign Type G
Exit Only Directional
3295
Estes Park, CO 80517
Alarado Business Park
420 Steamer Dr. Suite 100
Jimmy John's
3
5.0
END SECTION
SCALE: 1 1/2”= 1’-0”
B
NOTE: Paint all exposed fasteners to match adjacent finish
1
2
3
SPECIFICATIONS FOR (1) S/F ILLUMINATED DIRECTIONAL SIGN
SIGN CABINET= 1” alum. sq. tube frame with 1/8” alum. returns
GRAPHICS= First surface vinyl overlay
MOUNTING= Sign cabinet is internally attached to a 3” schedule 40 steel
pipe (3 1/2” actual O.D.) with caisson
P1 P.T.M. MP “Black” (Satin)
COLORS AND FINISHES
V1 3M Vinyl #3630-83 "Red" (Pantone 186C)
3M Vinyl #3630-22 "Black" (reverse weed & opaque)V2
1a SIGN FACE= 3/16" White acrylic w/ 1" Black trimcap
1 P1
V12 1a V22
0
Shop Drawing for:SD