Loading...
HomeMy WebLinkAboutPLANS SIgn 420 Steamer Dr 2020-03-0302-03-20 CCL Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 1.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDA 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Brian P. Charles L. 1.0 Site Plan 1 1.0 SITE PLAN SCALE: N.T.S. AAA BBB 3294 Alarado Business Park 420 Steamer Dr. Suite 101 Estes Park Health Estes Park, CO 80517 Rick B. December 18, 2019 Various wall signs 3294 AAA CHANNEL LETTERS Quantity (1) CCC CHANNEL LETTERS Quantity (1) BBB CHANNEL LETTERS Quantity (1) CCC CHANNEL LETTERS Quantity (1) DDD DDD CARE BC0 Shop Drawing for:SD 02-03-20 CCL Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 2.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEA 3294 1 420 Steamer Dr. Suite 101 Estes Park Health Estes Park, CO 80517 Alarado Business Park Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Rick B. Charles L. December 18, 2019 Various wall signs 3294 2.0 Elevations 1 2.0 SOUTH ELEVATION SCALE: 1/16" = 1'-0" 2 2.0 EAST ELEVATION SCALE: 1/16" = 1'-0" NOTE: Verify all dimensions with field survey, prior to fabrication 22'-10"22'-10"22'-10"25'-2"25'-2"25'-2"22'-10"22'-10"22'-10" 2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"2'-6 1/2"1'-5"1'-5"1'-5" ST-CST-CST-C ST-AST-AST-A ST-BST-BST-BOn estimate #3295On estimate #3295 for Jimmy John'sfor Jimmy John's On estimate #3295 for Jimmy John's ST-DST-DST-D 3 2.0 SIGNS ON 3D RENDERING SCALE: NTS 11'-9 1/2"11'-9 1/2"11'-9 1/2" Top of "URGENT" will matchTop of "URGENT" will match PHYSICAL THERAPYPHYSICAL THERAPY & URGENT CARE on N. Elev.& URGENT CARE on N. Elev. Top of "URGENT" will match PHYSICAL THERAPY & URGENT CARE on N. Elev. 22.43 SQ. FT. 32 SQ. FT. 72.31 SQ. FT. 89.34 SQ. FT. CARE B 243.98 SQ. FT. total C 27.9 SQ. FT. D0 Shop Drawing for:SD NOTE: Field verify raceway paint color to building surfacesNOTE: Field verify raceway paint color to building surfacesNOTE: Field verify raceway paint color to building surfaces 3" mounting clips placed as needed on 3" mounting clips placed as needed on back of racewayback of raceway 3" mounting clips placed as needed on back of raceway 5'- 0" (2nd Raceway)5'- 0" (2nd Raceway)5'- 0" (2nd Raceway) C H A N N E L LE T T E R Power InPower InPower In Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED .040" Returns.040" Returns.040" Returns 1" Trimcap &1" Trimcap & Acrylic FaceAcrylic Face 1" Trimcap & Acrylic Face LED power supply Raceway accessRaceway access SignComp #1976N SignComp #1976N Raceway access SignComp #1976N Bracing bracketsBracing brackets SignComp #1974N SignComp #1974N Bracing brackets SignComp #1974N 3" Raceway large3" Raceway large mounting clipsmounting clips SignComp #1988SignComp #1988 3" Raceway large mounting clips SignComp #1988 Mounting FastenersMounting Fasteners as requiredas required Mounting Fasteners as required Extruded RacewayExtruded Raceway SignComp #1970N SignComp #1970N Extruded Raceway SignComp #1970N ¹⁄" Fastener¹⁄" Fastener attachmentsattachments Letters toLetters to raceway raceway ¹⁄" Fastener attachments Letters to raceway SECTION N.T.S. 2 P1 5" Narrow5" Narrow channelchannel endcapendcap 5" Narrow channel endcap 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch 72.31 SQ. FT. CONSTRUCTION= MOUNTING= Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N). Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia 3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips. ACCESS= Removal of Top of raceway ELECTRICAL 120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave 6'-0" pigtail in seal-tite conduit). PRIMARY= 12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways Toggle switch on end of cabinet/raceway. SECONDARY= POWER DISCONNECT= 3 02-03-20 CCL Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 3.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDCA 2 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Brian P. Charles L. 3.0 EPH Channel Letters 3294 Estes Park Health Alarado Business Park 420 Steamer Dr. Suite 101 Estes Park, CO 80517 Rick B. December 18, 2019 Sign Type A Pan Channel Letters 3294 1 3.0 FRONT ELEVATION SCALE: 1/2”= 1’-0” COLOR SPECIFICATIONS NOTE: Paint all exposed fasteners to match adjacent finish 1 SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE A CHANNEL LETTERS MOUNTING= Mount flush to raceway TRIMCAP= LETTER TYPE= BACKS= RETURNS= ILLUMINATION= 1” White Jewelite Face-Lit pan channel letters .040" Pre-finished white aluminum .040" Pre-finished white aluminum (w/ weep holes) White Sloan Prism Mini LEDs DEPTH= 4" FACES= 3/16" White acrylic - #7328 (Digital print graphic on logo face) 2 RACEWAY 20'-0"20'-0"20'-0" 8'-5 3/4"8'-5 3/4"8'-5 3/4"5'-10 3/16"5'-10 3/16"5'-10 3/16"5'-1 1/4"5'-1 1/4"5'-1 1/4" 7'-5 5/8"7'-5 5/8"7'-5 5/8" 1'-3"1'-3"1'-3" 3'-7 3/8"3'-7 3/8"3'-7 3/8" 1 1 DP Digitally printed multicolor gradient graphic on white translucent vinyl P1 Raceway: P.T.M. Field Verify Mounting Surface C1 Pantone 7405 - CMYK 3/23/95/0 C2 Pantone 384 - CMYK 29/6/95/26 C3 Pantone 382 - CMYK 50/0/100/0 C4 Pantone 363 - CMYK 80/5/100/30 C5 Pantone 7459 - CMYK 65/12/12/15 BRAND COLORS P2 Letter Returns: Pre-finished "White" P21 DP C1 C2 C3 C4 C5 DP DP DP DP DP 2 3.0 END VIEW SCALE: 1/2”= 1’-0” Power conduit neededPower conduit needed between racewaysbetween raceways Power conduit needed between raceways 2 P1 B 5¹⁄"5¹⁄"5¹⁄"1'-4"1'-4"1'-4" On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch 4"4"4" 3 ¹⁄"3 ¹⁄"3 ¹⁄" 3 3.0 PLAN VIEW SCALE: 1/2”= 1’-0” 2 P1 11'- 4" (1st Raceway)11'- 4" (1st Raceway)11'- 4" (1st Raceway) 7'- 5" (3rd Raceway beyond)7'- 5" (3rd Raceway beyond)7'- 5" (3rd Raceway beyond) 0 Shop Drawing for:SD V.I.F. Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 4.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDCA 4 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Charles L. 4.0 UC North Elev Channel Letters 3294 Estes Park Health Estes Park, CO 80517 Alarado Business Park 420 Steamer Dr. Suite 101 Rick B. December 18, 2019 Sign Type B Pan Channel Letters 3294 1 4.0 FRONT ELEVATION SCALE: 1/2”= 1’-0” COLOR SPECIFICATIONS NOTE: Paint all exposed fasteners to match adjacent finish 1 SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE B CHANNEL LETTERS MOUNTING= Mount flush to raceway TRIMCAP= LETTER TYPE= BACKS= RETURNS= ILLUMINATION= 1” White Jewelite for letters Face-Lit pan channel letters .040" Pre-finished white aluminum .040" Pre-finished white aluminum (w/ weep holes) White Sloan Prism Mini LEDs DEPTH= 4" FACES= 3/16" White acrylic - #7328 4"4"4" 2 RACEWAY 15'-5 5/8"15'-5 5/8"15'-5 5/8" 8'-10"8'-10"8'-10" 1'-6"1'-6"1'-6" 1 P1 P2 Letter Returns: Pre-finished "White" P21 2 4.0 END VIEW SCALE: 1/2”= 1’-0” 5'-0"5'-0"5'-0" 3 ¹⁄"3 ¹⁄"3 ¹⁄" 2 P1 5¹⁄"5¹⁄"5¹⁄" 15'- 4 ³⁄" (Raceway)15'- 4 ³⁄" (Raceway)15'- 4 ³⁄" (Raceway) PLAN VIEW SCALE: 1/2”= 1’-0” 3" Mounting clips placed as3" Mounting clips placed as needed on back of racewayneeded on back of raceway 3" Mounting clips placed as needed on back of raceway CH A N N E L L E T T E R Power InPower InPower In Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED .040" Returns.040" Returns.040" Returns 1" Trimcap &1" Trimcap & Acrylic FaceAcrylic Face 1" Trimcap & Acrylic Face LED power supply Raceway accessRaceway access SignComp #1976N SignComp #1976N Raceway access SignComp #1976N Bracing bracketsBracing brackets SignComp #1974N SignComp #1974N Bracing brackets SignComp #1974N 3" Raceway large3" Raceway large mounting clipsmounting clips SignComp #1988SignComp #1988 3" Raceway large mounting clips SignComp #1988 Mounting FastenersMounting Fasteners as requiredas required Mounting Fasteners as required Extruded RacewayExtruded Raceway SignComp #1970N SignComp #1970N Extruded Raceway SignComp #1970N ¹⁄" Fastener¹⁄" Fastener attachmentsattachments Letters toLetters to raceway raceway ¹⁄" Fastener attachments Letters to raceway SECTION N.T.S. 2 P1 5" Narrow5" Narrow channelchannel endcapendcap 5" Narrow channel endcap 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch22.43 SQ. FT. 3 4.0 CONSTRUCTION= MOUNTING= Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N). Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia 3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips. ACCESS= Removal of Top of raceway ELECTRICAL 120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave 6'-0" pigtail in seal-tite conduit). PRIMARY= 12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways Toggle switch on end of cabinet/raceway. SECONDARY= POWER DISCONNECT= 3 B0 Shop Drawing for:SD CCL 02-03-20 Brian P. Raceway: P.T.M. Field Verify Mounting Surface COLOR SPECIFICATIONS NOTE: Paint all exposed fasteners to match adjacent finish 1 CHANNEL LETTERS MOUNTING= Mount flush to raceway TRIMCAP= LETTER TYPE= BACKS= RETURNS= ILLUMINATION= 1” White Jewelite for letters Face-Lit pan channel letters .040" Pre-finished white aluminum .040" Pre-finished white aluminum (w/ weep holes) White Sloan Prism Mini LEDs DEPTH= 4" FACES= 3/16" White acrylic - #7328 4"4"4" 2 RACEWAY P1 P2 Letter Returns: Pre-finished "White" P21 3 ¹⁄"3 ¹⁄"3 ¹⁄" 5¹⁄"5¹⁄"5¹⁄" 18'- 6 1/2" (Raceway)18'- 6 1/2" (Raceway)18'- 6 1/2" (Raceway) PLAN VIEW SCALE: 1/2”= 1’-0” CH A N N E L L E T T E R Power InPower InPower In Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED .040" Returns.040" Returns.040" Returns 1" Trimcap &1" Trimcap & Acrylic FaceAcrylic Face 1" Trimcap & Acrylic Face LED power supply Raceway accessRaceway access SignComp #1976N SignComp #1976N Raceway access SignComp #1976N Bracing bracketsBracing brackets SignComp #1974N SignComp #1974N Bracing brackets SignComp #1974N 3" Raceway large3" Raceway large mounting clipsmounting clips SignComp #1988SignComp #1988 3" Raceway large mounting clips SignComp #1988 Mounting FastenersMounting Fasteners as requiredas required Mounting Fasteners as required Extruded RacewayExtruded Raceway SignComp #1970N SignComp #1970N Extruded Raceway SignComp #1970N ¹⁄" Fastener¹⁄" Fastener attachmentsattachments Letters toLetters to raceway raceway ¹⁄" Fastener attachments Letters to raceway SECTION N.T.S. 5" Narrow5" Narrow channelchannel endcapendcap 5" Narrow channel endcap 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch27.9 SQ. FT. CONSTRUCTION= MOUNTING= Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N). Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia 3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips. ACCESS= Removal of Top of raceway ELECTRICAL 120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave 6'-0" pigtail in seal-tite conduit). PRIMARY= 12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways Toggle switch on end of cabinet/raceway. SECONDARY= POWER DISCONNECT= 3 Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 5.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDA 8 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Charles L. 5.0 RS Channel Letters 3294 Alarado Business Park Estes Park, CO 80517 Estes Park Health 420 Steamer Dr. Suite 101 Rick B. December 18, 2019 Pan Channel Letters Sign Type C 3294 1 5.0 FRONT ELEVATION SCALE: 1/2”= 1’-0” 2 5.0 END VIEW SCALE: 1/2”= 1’-0” B 18'-7 3/16"18'-7 3/16"18'-7 3/16" 7'-4"7'-4"7'-4" 1'-6"1'-6"1'-6" 10'-5 13/16"10'-5 13/16"10'-5 13/16" 3 5.0 SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE C 3" Mounting clips placed as3" Mounting clips placed as needed on back of racewayneeded on back of raceway 3" Mounting clips placed as needed on back of raceway C 2 P1 2 P11 0 Shop Drawing for:SD 02-03-20 CCL Brian P. Raceway: P.T.M. Field Verify Mounting Surface Power conduit neededPower conduit needed between racewaysbetween raceways Power conduit needed between raceways Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 6.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDCA 7 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Charles L. 6.0 UC East Elev Channel Letters 3294 Alarado Business Park Estes Park Health Estes Park, CO 80517 420 Steamer Dr. Suite 101 Rick B. December 18, 2019 Pan Channel Letters Sign Type D 3294 1 6.0 FRONT ELEVATION SCALE: 1/2”= 1’-0” SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN TYPE D 1'-6"1'-6"1'-6" CARE P21 2 6.0 END VIEW SCALE: 1/2”= 1’-0” 8'-10"8'-10"8'-10" 1'-6"1'-6"1'-6" 5'-0"5'-0"5'-0" 1 2 P13'-7 3/8"3'-7 3/8"3'-7 3/8" B COLOR SPECIFICATIONS NOTE: Paint all exposed fasteners to match adjacent finish 1 CHANNEL LETTERS MOUNTING= Mount flush to raceway TRIMCAP= LETTER TYPE= BACKS= RETURNS= ILLUMINATION= 1” White Jewelite for letters Face-Lit pan channel letters .040" Pre-finished white aluminum .040" Pre-finished white aluminum (w/ weep holes) White Sloan Prism Mini LEDs DEPTH= 4" FACES= 3/16" White acrylic - #7328 2 RACEWAY P1 P2 Letter Returns: Pre-finished "White" 5¹⁄"5¹⁄"5¹⁄" 8'- 10" (Raceway)8'- 10" (Raceway)8'- 10" (Raceway) PLAN VIEW SCALE: 1/2”= 1’-0” 3" Mounting clips placed as3" Mounting clips placed as needed on back of racewayneeded on back of raceway 3" Mounting clips placed as needed on back of raceway CH A N N E L L E T T E R Power InPower InPower In Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED .040" Returns.040" Returns.040" Returns 1" Trimcap &1" Trimcap & Acrylic FaceAcrylic Face 1" Trimcap & Acrylic Face LED power supply Raceway accessRaceway access SignComp #1976N SignComp #1976N Raceway access SignComp #1976N Bracing bracketsBracing brackets SignComp #1974N SignComp #1974N Bracing brackets SignComp #1974N 3" Raceway large3" Raceway large mounting clipsmounting clips SignComp #1988SignComp #1988 3" Raceway large mounting clips SignComp #1988 Mounting FastenersMounting Fasteners as requiredas required Mounting Fasteners as required Extruded RacewayExtruded Raceway SignComp #1970N SignComp #1970N Extruded Raceway SignComp #1970N ¹⁄" Fastener¹⁄" Fastener attachmentsattachments Letters toLetters to raceway raceway ¹⁄" Fastener attachments Letters to raceway SECTION N.T.S. 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch 4"4"4" 3 ¹⁄"3 ¹⁄"3 ¹⁄" 5" Narrow5" Narrow channelchannel endcapendcap 5" Narrow channel endcap 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch32 SQ. FT. CONSTRUCTION= MOUNTING= Sign Comp 5" (1 piece) narrow channel extruded raceway (#1970N), internal brace (#1974N). Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia 3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips. ACCESS= Removal of Top of raceway ELECTRICAL 120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave 6'-0" pigtail in seal-tite conduit). PRIMARY= 12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways Toggle switch on end of cabinet/raceway. SECONDARY= POWER DISCONNECT= 3 3 6.0 2 P1 5'- 8" (2nd Raceway)5'- 8" (2nd Raceway)5'- 8" (2nd Raceway) 02-03-20 CCL Brian P. 0 Shop Drawing for:SD Raceway: P.T.M. Field Verify Mounting Surface TAK 02-18-20 Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 1.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 2 Revision Notes: 2 3 TBD GFEDA 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Brian P. Charles L. 1.0 Site Plan 1 1.0 SITE PLAN SCALE: N.T.S. AAA 3295 Rick B. December 19, 2019 Channel Letter wall sign 3295 AAA CHANNEL LETTERS Quantity (1)Estes Park, CO 80517 Alarado Business Park Jimmy John's 420 Steamer Dr. Suite 100 BC BBB DRIVE THRU DIRECTIONAL Quantity (1) CCC EXIT ONLY DIRECTIONAL Quantity (1) BBB CCC 0 Shop Drawing for:SD 1 1 02-03-20 CCL Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 2.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEA 3295 1 Alarado Business Park Estes Park, CO 80517 420 Steamer Dr. Suite 100 Jimmy John's Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Brian P. Rick B. Charles L. December 19, 2019 Channel Letters Wall Sign 3295 2.0 Elevations 1 2.0 SOUTH ELEVATION SCALE: 1/16" = 1'-0" URGENT CARE NOTE: Verify all dimensions with field survey, prior to fabrication 22'-10"22'-10"22'-10"25'-2"25'-2"25'-2"22'-10"22'-10"22'-10" On estimate #3294On estimate #3294 for Estes Park Healthfor Estes Park Health On estimate #3294 for Estes Park HealthST-EST-EST-E 2 2.0 SIGNS ON 3D RENDERING SCALE: NTS 15'-8³⁄"15'-8³⁄"15'-8³⁄" On estimate #3294On estimate #3294 for Estes Park Healthfor Estes Park Health On estimate #3294 for Estes Park Health On estimate #3294On estimate #3294 for Estes Park Healthfor Estes Park Health On estimate #3294 for Estes Park Health 38'-0"38'-0"38'-0" B 89.34 SQ. FT. CD Field Verify color matchField Verify color match to building for raceway paintto building for raceway paint Field Verify color match to building for raceway paint 0 Shop Drawing for:SD CCL 02-03-20 Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval AB Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc.Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Prototype Seg. No.0 PT# Sheet No. 3.0 Rev. No. Dot No. W.O. No. By: Date:AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 Revision Notes: 2 3 TBD GFEDA 2,3 1 Design Proposal for:DP Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: Brian P. Charles L. 3.0 JJ Channel Letters 3295 Rick B. December 18, 2019 Pan Channel Letters Sign Type E 3295 1 3.0 FRONT ELEVATION SCALE: 1/2”= 1’-0” COLOR SPECIFICATIONS 1 SPECIFICATIONS FOR (1) FACE LIT PAN CHANNEL LETTER SIGN CHANNEL LETTERS MOUNTING= Mount flush to raceway TRIMCAP= LETTER TYPE= BACKS= RETURNS= ILLUMINATION= 1” Black Jewelite for letters Face-Lit pan channel letters .040" Pre-finished White aluminum .040" Pre-finished Black aluminum (w/ weep holes) White Sloan Prism Mini LEDs DEPTH= 5" FACES= 3/16" White acrylic - #7328 & Vinyl overlay ( logo on disc/drive thru, & a 7/8" border on letter edges) 2 RACEWAY CONSTRUCTION= MOUNTING= Sign Comp 5" (1 piece) narrow channel raceway extruded raceway (#1970N), internal brace (#1974N). Hinged top opening lid (#1976), & 5" narrow end caps (#5987N-5). Painted to blend in with building fascia 3" large slide in mounting clips (#1988) w/ 1/2" holes for hanging/installation Mount to existing fascia w/ 3/8" fasteners (as req.) through mounting clips. ACCESS= Hinged lid top or bottom of raceway ELECTRICAL 120V electrical to sign & final hook up by others (Install ½" seal-tite fittings in cabinet/raceway back & leave 6'-0" pigtail in seal-tite conduit). J-Box TBD PRIMARY= 12V LED wire leads jumped in cabinets/raceways. 12V LED transformers mounted in cabinets/raceways Toggle switch on end of cabinet/raceway. SECONDARY= POWER DISCONNECT= 3 V1 P1 Raceway: Field Verify color match for raceway paint Pantone 186c - 3M 3630-83 "Red" 3M 3630-22 "Black" Jimmy John's 420 Steamer Dr. Suite 100 Alarado Business Park Estes Park, CO 80517 3 3.0 PLAN VIEW SCALE: 1/2”= 1’-0” V2 P2 Returns: Pre-finished "Black" 2 3.0 END VIEW SCALE: 1/2”= 1’-0” B 5"5"5" 3 ¹⁄"3 ¹⁄"3 ¹⁄" (2)Raceways(2)Raceways w/ 5" Narroww/ 5" Narrow channelchannel endcapendcap (2)Raceways w/ 5" Narrow channel endcap 2 P1 On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch 22'- 5" (Raceway)22'- 5" (Raceway)22'- 5" (Raceway) C 2' - 1 0 " 2' - 1 0 " 2' - 1 0 " 2'- 10"2'- 10"2'- 10"9'- 2"9'- 2"9'- 2"9'- 5¹⁄"9'- 5¹⁄"9'- 5¹⁄" 5¹⁄"5¹⁄"5¹⁄" 1'- 8³⁄"1'- 8³⁄"1'- 8³⁄" 22'- 11"22'- 11"22'- 11" On/OffOn/Off ToggleToggle switchswitch On/Off Toggle switch 2 P1 1 V2 V1 3" Flange attachment points placed as3" Flange attachment points placed as needed on back of racewayneeded on back of raceway 3" Flange attachment points placed as needed on back of raceway 2 P1 89.34 SQ. FT. C H A N N E L L E T T E R Power InPower InPower In Sloan Prism Mini LEDSloan Prism Mini LEDSloan Prism Mini LED .040" Returns.040" Returns.040" Returns 1" Trimcap &1" Trimcap & Acrylic FaceAcrylic Face 1" Trimcap & Acrylic Face LED power supply Raceway accessRaceway access SignComp #1976N SignComp #1976N Raceway access SignComp #1976N Bracing bracketsBracing brackets SignComp #1974N SignComp #1974N Bracing brackets SignComp #1974N 3" Raceway large3" Raceway large mounting clipsmounting clips SignComp #1988SignComp #1988 3" Raceway large mounting clips SignComp #1988 Mounting FastenersMounting Fasteners as requiredas required Mounting Fasteners as required Extruded RacewayExtruded Raceway SignComp #1970N SignComp #1970N Extruded Raceway SignComp #1970N ¹⁄" Fastener¹⁄" Fastener attachmentsattachments Letters toLetters to raceway raceway ¹⁄" Fastener attachments Letters to raceway SECTION N.T.S. 12'- 4" (2nd Raceway- beyond)12'- 4" (2nd Raceway- beyond)12'- 4" (2nd Raceway- beyond) On/Off toggle switchOn/Off toggle switchOn/Off toggle switch 1'- 1⁵⁄"1'- 1⁵⁄"1'- 1⁵⁄" 12'- 5¹⁄"12'- 5¹⁄"12'- 5¹⁄" 1 V2 (2) Sign Comp(2) Sign Comp 5" One Piece 5" One Piece narrow raceways narrow raceways (2) Sign Comp 5" One Piece narrow raceways 1 V2 1 P2 J-BoxJ-Box locationlocation TBDTBD J-Box location TBD Bottom racewayBottom raceway lid side down tolid side down to run conduitrun conduit between wherebetween where neededneeded Bottom raceway lid side down to run conduit between where needed NOTE: Paint all exposed fasteners to match adjacent finish 0 Shop Drawing for:SD Raceway to be built in two piecesRaceway to be built in two piecesRaceway to be built in two pieces Prototype Seg. No.0 PT# AB DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval Sheet No. Rev. No. Dot No. W.O. No. By: Date: Revision Notes: Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc. Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: 02-03-20 CCL 4.0 AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 2 3 TBD GFEDCA 3295 4 1 Design Proposal for:DP Brian P. 1 4.0 FRONT ELEVATION SCALE: 1 1/2”= 1’-0” 2 4.0 END VIEW SCALE: 1 1/2”= 1’-0” 1' - 4 " 1' - 4 " 1' - 4 " 3'- 2"3'- 2"3'- 2" 1 P1 4.22 SQ. FT. NOTE: Paint all exposed fasteners to match adjacent finish 1 2 3 SPECIFICATIONS FOR (1) S/F ILLUMINATED DIRECTIONAL SIGN SIGN CABINET= 1” alum. sq. tube frame with 1/8” alum. returns GRAPHICS= First surface vinyl overlay MOUNTING= Sign cabinet is internally attached to a 3” schedule 40 steel pipe (3 1/2” actual O.D.) with caisson 0’-8"0’-8"0’-8" 3 P1 3'-0"3'-0"3'-0" hardware 3/8" Inset 1'-0"1'-0"1'-0" 1'-0" Diameter Concrete caisson Steel pipe Steel angle- weld to pipe Cabinet frame typ. P1 P.T.M. MP “Black” (Satin) 1' - 8 " 1' - 8 " 1' - 8 " 3' - 0 " 3' - 0 " 3' - 0 " 3” Schedule 40 steel pipe3” Schedule 40 steel pipe (0’-3 ¹⁄" actual O.D.)(0’-3 ¹⁄" actual O.D.) 3” Schedule 40 steel pipe (0’-3 ¹⁄" actual O.D.) Charles L. 4.0 JJ Drive Thru Directional Rick B. January 13, 2019 Sign Type F Drive Thru Directional 3295 Alarado Business Park Jimmy John's 420 Steamer Dr. Suite 100 Estes Park, CO 80517 V1 3 4.0 END SECTION SCALE: 1 1/2”= 1’-0” B COLORS AND FINISHES V1 3M Vinyl #3630-83 "Red" (Pantone 186C) 3M Vinyl #3630-22 "Black" (reverse weed & opaque)V2 1a SIGN FACE= 3/16" White acrylic w/ 1" Black trimcap 2 1a V22 0 Shop Drawing for:SD Prototype Seg. No.0 PT# AB DateProduction Mgr. Approval DateProject Mgr. Approval DateAccount Mgr. Approval DateP&D Mgr. Approval Sheet No. Rev. No. Dot No. W.O. No. By: Date: Revision Notes: Client Approval NOTE: Please ensure all red line changes are noted on this drawing prior to returning it to ADCON. Subsequent to ADCON incorporating the red line changes requested on this drawing, any further changes will result in additional billing at the rate of $86 per hour. Approved As Noted Revise And Resubmit Approved Signature Date Advertising Concepts Inc. 3725 Canal Drive, Fort Collins, CO 80524 970 484 3637 www.adconsigns.com These documents and plans have been created by and are the exclusive intellectual property of Adcon Inc. Any unauthorized use, disclosure, dissemination or dupli- cation of any of the information contained herein may result in liability under applicable laws. Drawn by: Account Manager: Project Manager: Date: Sign Type: Design/ Quote #: File Name: CCL 02-03-20 5.0 AB AB 12 12 11 11 10 10 9 9 8 8776 6 5 5 4 4 3 3 2 211 2 3 TBD GFEDCA 3295 4 1 Design Proposal for:DP Brian P. 1 5.0 FRONT ELEVATION SCALE: 1 1/2”= 1’-0” 2 5.0 END VIEW SCALE: 1 1/2”= 1’-0” 1' - 4 " 1' - 4 " 1' - 4 " 3'- 2"3'- 2"3'- 2"4.22 SQ. FT. 0’-8"0’-8"0’-8" 3 P1 3'-0"3'-0"3'-0" 3/8" Inset hardware 1'-0"1'-0"1'-0" 1'-0" Diameter Concrete caisson Steel pipe Steel angle- weld to pipe Cabinet frame typ. 1' - 8 " 1' - 8 " 1' - 8 " 3' - 0 " 3' - 0 " 3' - 0 " 3” Schedule 40 steel pipe3” Schedule 40 steel pipe (0’-3 ¹⁄" actual O.D.)(0’-3 ¹⁄" actual O.D.) 3” Schedule 40 steel pipe (0’-3 ¹⁄" actual O.D.) Charles L. 5.0 JJ Exit Only Directional Rick B. January 13, 2019 Sign Type G Exit Only Directional 3295 Estes Park, CO 80517 Alarado Business Park 420 Steamer Dr. Suite 100 Jimmy John's 3 5.0 END SECTION SCALE: 1 1/2”= 1’-0” B NOTE: Paint all exposed fasteners to match adjacent finish 1 2 3 SPECIFICATIONS FOR (1) S/F ILLUMINATED DIRECTIONAL SIGN SIGN CABINET= 1” alum. sq. tube frame with 1/8” alum. returns GRAPHICS= First surface vinyl overlay MOUNTING= Sign cabinet is internally attached to a 3” schedule 40 steel pipe (3 1/2” actual O.D.) with caisson P1 P.T.M. MP “Black” (Satin) COLORS AND FINISHES V1 3M Vinyl #3630-83 "Red" (Pantone 186C) 3M Vinyl #3630-22 "Black" (reverse weed & opaque)V2 1a SIGN FACE= 3/16" White acrylic w/ 1" Black trimcap 1 P1 V12 1a V22 0 Shop Drawing for:SD