Loading...
HomeMy WebLinkAboutPLANS B-11191 JImmy Johns 420 Steamer Dr 100 2019-12-12ABBREVIATIONS:PROJECT INFORMATION:VICINITY MAP:SHEET INDEX: SYMBOL LEGEND: XXXXX XXX X.X XX XX XX XX ROOM NAME (TOP) AND ROOM INTERIOR / EXTERIOR ELEVATION - DETAIL REFERENCE - DETAIL No. (TOP), BUILDING SECTION - SECTION No. (TOP), WALL SECTION - SECTION No. (TOP), BUILDING COLUMN GRID LINE KEYED NOTE - SEE KEYED NOTES EQUIPMENT REFERENCE - SEE EQUIPMENT WALL TYPE & DECOR XX XX XX XX ARCHITECTURAL A-7 A-5 CABINET DETAILS INTERIOR ELEVATIONS T-1 TITLE SHEET A-8 XX XX M-1 MECHANICAL PLAN AND DETAILS MECHANICAL P-1 PLUMBING PLANS PLUMBING E-1 ELECTRICAL E-2 A-3 EQUIPMENT PLAN AND SCHEDULE A-1 FLOOR PLAN AND DETAILS A-9 P-2 PLUMBING SCHEDULE AND DETAILS P-3 PLUMBING ISOMETRICS MEP-1 MEP GENERAL NOTES FLOOR FINISH PLAN AND SCHEDULE INTERIOR ELEVATIONS A-6 M-2 MECHANICAL NOTES AND SCHEDULES MEP-2 MEP SPECIFICATIONS ELECTRICAL POWER PLAN AND SCHEDULES ELECTRICAL LIGHTING PLAN AND SCHEDULES SP-1 SPECIFICATIONS DETAILS A-1.1 FRAMING PLAN AND DETAILS XX COM-1 COMMUNICATIONS / DATA COMMUNICATIONS / DATA PLAN AND DETAILS A-4 RESTROOM PLAN AND ELEVATIONS DOOR TYPE X X X XX EXTERIOR MATERIAL (TOP) AND EXTERIOR INTERIOR FINISHES & DECOR FLOOR FINISHES CEILING FINISHES FINISH (BOTTOM) NUMBER (BOTTOM) ELEVATION No. (TOP), SHEET No. (BOTTOM) SHEET No. (BOTTOM) SHEET No. (BOTTOM) SHEET No. (BOTTOM) COORDINATION SCHEDULE WINDOW TYPEX NORTH A-2 REFLECTED CELING PLAN AND DETAILS A-10 E-3 ELECTRICAL PANELS SCHEDULES INTERIOR ELEVATIONS MEP-3 ALTERNATE WALK-INS SPECIFICATIONS SPECIFICATIONS A-12 ARCHITECTURE SITE PLAN DRIVE-THRU DETAILSA-11 CABINET DETAILSA-9.1 CONTRACTOR NOTE: ALL INFORMATION, DETAILS, AND SPECIFICATIONS AS INCLUDED IN THE JIMMY JOHN'S CONSTRUCTION MANUAL ARE TO BE FULLY REVIEWED AND INCORPORATED INTO THE CONSTRUCTION OF THIS PROJECT. TENANT IMPROVEMENT / STORE # 4040 - SANDWICH FACTORY DESIGN 420 STEAMER DRIVE, SUITE 100 ESTES PARK, COLORADO 80517 PROJECT MANAGER : CHRIS COOPER A.I.A ALARADO ENTERPRISES, LLC 1911 ARROWHEAD DRIVE HOLDREGE, NEBRASKA 68949 CONTACT MR. RYAN WELLS ryan.wells@nutrien.com PHONE E-MAIL 308 . 991 . 3432 - -FAX PROJECT ADDRESS PROJECT DESCRIPTION TENANT IMPROVEMENT OCCUPANCY B OCCUPANT LOAD 37 420 STEAMER DRIVE, SUITE 100 ESTES PARK, COLORADO 80517 AREA CALCULATIONS TOTAL OCCUPANTS RESTAURANT FRONT OF HOUSE : 673 SQ. FT. RESTAURANT BACK OF HOUSE : 586 SQ. FT. COOLER/FREEZER : 78 SQ. FT. TOTAL : 1337 SQ. FT. EXITS (1) EXIT REQUIRED (2) EXITS PROVIDED CONSTRUCTION TYPE TYPE V-B UNCONCENTRATED TABLES AND CHAIRS: 472 S.F./15 = 31.4 KITCHEN AREA : 586 SQ. FT. / 200 = 2.93 : 31 : 37 CONSTRUCTION TYPE FULLY SPRINKLED PROJECT DIRECTORY: BUILDING SAFETY PHONE TOWN OF ESTES PARK FAX 170 MACGREGOR AVENUE ESTES PARK, COLORADO 80517 970 . 577 . 3726 DESIGN CODES : 3 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRICAL CODE 970 . 586 . 0249 OWNER: JIMMY JOHN'S 2202 FOX DRIVE - 217 . 359 . 2956 construction@jimmyjohns.com - PHONE FAX E-MAIL CONTACT CHAMPAIGN, ILLINOIS 61820 217 . 356 . 9900 cooper@arizado.net MR. CHRIS COOPER PHONE FAX E-MAIL CONTACT 480 . 268 . 2900 480 . 268 . 2905 a.d. ArizaDo ARCHITECT: 1255 WEST RIO SALADO PARKWAY SUITE 207 TEMPE, ARIZONA 85281 FRANCHISEE: STANDING/QUEING AREA: 40 / 15 = 2.67 : 3 PLUMBING:MECHANICAL: ELECTRICAL: 1 1 . D E C E M B E R . 2 0 1 9 cooper@arizado.net MR. CHRIS COOPER PHONE FAX E-MAIL CONTACT 480 . 268 . 2900 480 . 268 . 2905 a.d. ArizaDo 1255 WEST RIO SALADO PARKWAY SUITE 207 TEMPE, ARIZONA 85281 cooper@arizado.net MR. CHRIS COOPER PHONE FAX E-MAIL CONTACT 480 . 268 . 2900 480 . 268 . 2905 a.d. ArizaDo 1255 WEST RIO SALADO PARKWAY SUITE 207 TEMPE, ARIZONA 85281 cooper@arizado.net MR. CHRIS COOPER PHONE FAX E-MAIL CONTACT 480 . 268 . 2900 480 . 268 . 2905 a.d. ArizaDo 1255 WEST RIO SALADO PARKWAY SUITE 207 TEMPE, ARIZONA 85281 ENVIRONMENTAL HEALTH PHONE LARIMER COUNTY HEALTH DEPARTMENT 200 W. OAK STREET FORT COLLINS, COLORADO 80521 970 . 498 . 6775 -FAX T-1 TITLE SHEET RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 1 1 Reviewed by SAFEbuilt 12/12/2019 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 12/12/2019 B-11191 SP-1 SPECIFICATIONS RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 S P E C I F I C A T I O N S PROVIDE WRITTEN GUARANTEES FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF INSTRUCTIONS AND GUARANTEES FOR ALL EQUIPMENT AND MATERIALS INSTALLED. INSPECTION. UPON INSPECTION, PROVIDE WRITTEN OPERATION AND MAINTENANCE 26. OF THE WORK OR DAMAGE TO THE ITEMS. REPLACE DAMAGED OR UNFIT MATERIALS, STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS TO AVOID DISRUPTION 25. ACCORDANCE WITH THE MOST CURRENT WRITTEN MANUFACTURER'S INSTRUCTIONS. COMPLY WITH MANUFACTURER'S INSTRUCTIONS, PERFORM THE WORK IN STRICT 24. THROUGHOUT THE PROJECT OR THEY SHALL BE REJECTED. THAT ARE SIMILAR SHALL BE THE SAME TYPE, MODEL AND STYLE FOR THE SAME USE IT IS SPECIFICALLY DESIGNED OR SPECIFIED. ALL MATERIALS AND EQUIPMENT 23. 22. UNAUTHORIZED PERSONNEL UNTIL ACCEPTANCE BY OWNER. PROPERTY FROM THEFT AND VANDALISM AND THE PREMISES FROM ENTRY BY PROTECT THE WORK, STORED PRODUCTS, CONSTRUCTION EQUIPMENT AND OWNER'S 21. CONTRACTOR HAS USED PRODUCTS INCORRECTLY LABELED BY THE MANUFACTURER OR OWNER AND REIMBURSE ALL THE COSTS OF THE TESTING TO THE OWNER, UNLESS THE CONTRACTOR SHALL CORRECT THE DEFICIENCY AT NO ADDITIONAL COSTS TO THE GENERALLY ACCEPTED TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE AT THE OWNER'S COST. IF THE REQUESTED TEST SHOWN NON-CONFORMANCE TO THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL ENLIST A TESTING LABORATORY 20. REPLACE DAMAGED SURFACE AND MATERIALS OF THE PREVIOUSLY INSTALLED WORK BY 19. ACCESSORIES, EQUIPMENT AND FIXTURES INSTALL REQUIRED BLOCKING AT NO 18. ALL WORK BY SKILLED MECHANICS IN ACCORDANCE WITH ESTABLISHED STANDARDS OF THE HIGHEST QUALITY FINISHED PRODUCT, EXPRESSED OR IMPLIED. PERFORM 17. CONDITIONS, THE ONE HAVING THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, CASE OF CONFLICT BETWEEN THE PROJECT REQUIREMENTS AND/OR EXISTING EXISTING CONDITIONS PRIOR TO CONSTRUCTION, FABRICATION, OR PURCHASING. IN 16. OWNER TO MINIMIZE CONFLICT AND FACILITATE THE OWNER'S OPERATION. DURING THE FINAL STAGE OF CONSTRUCTION. COORDINATE AND COOPERATE WITH THE 15. MATERIALS SHALL BE LEFT IN ONE LOCATION UPON OWNER'S REPRESENTATIVE'S B. ONE FULL BOX OF EACH CERAMIC FLOOR TILE FREE FROM NICKS, SCRATCHES OR CRACKS. A. ONE FULL GALLON OF EACH PAINT COLOR IN A CLEAN, TIGHTLY CLOSED CAN, FROM THE SAME MATERIAL, LOT OR RUN USED TO CONSTRUCT AND FINISH THE 14. ITEMS SHALL OPERATE SMOOTHLY WITHOUT STICKING OR BINDING AND WITHOUT F. ALL JOINTS SHALL BE TIGHT, STRAIGHT, EVEN AND SMOOTH. ALL OPERABLE FINAL ACCEPTANCE OF THE WORK. AT NO COST TO THE OWNER. HAS MADE PREVIOUSLY APPROVED CHANGES. OTHER TRADES, INSTALLERS AND SUBCONTRACTORS. ADDITIONAL COST TO THE CONTRACT. WORKMANSHIP IN EACH OF THE VARIOUS TRADES. AS APPROVED BY JIMMY JOHN'S. DIRECTION AND APPROVAL. C. ONE-HALF BAG OF TILE GROUT. AND CLEARLY MARKED. EXCESSIVE "PLAY" OR LOOSENESS. PROJECT: CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 1.0 MIL DRY FILM MATERIALS, PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC 16. WHERE ALUMINUM ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR THICKNESS. E. ALL CORNERS AND EDGES SHALL BE STRAIGHT AND TRUE WITHOUT DENTS, D. WALL AND SOFFIT INTERSECTIONS SHALL BE 90° OR THE EXACT ANGLE C. ALL HORIZONTAL SURFACES SHALL BE LEVEL OR CONSTRUCTED TO THE EXACT MEASURED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE SURFACE HORIZONTAL SURFACES SHALL NOT BE GREATER THAN 1/8" IN 10'-0" AS B. THE MAXIMUM DEVIATION FROM THE TRUE PLANE FOR VERTICAL AND A. ALL VERTICAL SURFACES SHALL BE PLUMB OR CONSTRUCTED TO THE EXACT 13. WAVES OR BULGES OR OTHER BLEMISHES. INDICATED OR INTENDED. ANGLE INDICATED OR INTENDED. SLOPES OR ANGLES INDICATED. FOLLOWING TOLERANCES SHALL APPLY TO ALL WORK: B. REPAIR OR REPLACEMENT OF PROPERTY DAMAGED DURING FINAL COMPLETION OF A. POWER VACUUMING THE ENTIRE SPACE. MATERIALS, UNLESS REQUESTED BY THE OWNER. CLEAN-UP SHALL BE INCLUDED AND NOT THE PREMISES NEAT, CLEAN AND CLEAR OF TOOLS, EQUIPMENT AND SURPLUS 27. THE PROJECT. BE LIMITED TO: THAT DOORS OPEN FREELY WITHOUT BINDING, AND WHEN CLOSED, WILL LATCH OF DOORS AS SPECIFIED WITH 3/32" CLEARANCE AT MEETING EDGES. DEMONSTRATE FOR CARPETING AND MAKE NO JOBSITE FIT IN CUTS UNLESS APPROVED. HANG PAIRS FOR "UNDERCUTS" OR OTHER DEVIATIONS IN FIT. VERIFY CLEARANCES REQUIRED CLEARANCE AT TOPS AND 3/8" CLEARANCE AT BOTTOM, UNLESS SPECIFICALLY NOTED 11. MANUFACTURER AND CONFIRM TYPE, LOCATION, AND SPECIAL REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING. PROPERLY. 10. 9. SHIMS BEFORE FASTENING. LEAVE READY TO RECEIVE SEALANT WHERE INDICATED ON CONSTRUCTION OF ADJACENT WALLS. ADJUST FRAME LOCATIONS AS NECESSARY USING FASTENINGS: ANCHOR TO ADJOINING WALLS WITH SPECIFIED ANCHORS. BRACE FLOOR ANCHORS TO FLOOR CONSTRUCTION WITH APPROVED TYPE MECHANICAL RIGID, PLUMB, LEVEL AND TRUE. ALIGN WITH ADJACENT CONSTRUCTION. SECURE 8. COAT TO ALL EXPOSED SURFACES. LEAVE READY TO RECEIVE FINISH PAINTING. AND IMPERFECTIONS. APPLY UNIFORM COAT OF MANUFACTURER'S STANDARD PRIME 7. REQUIRED FOR A SECURE INSTALLATION AND SHALL BE IN ACCORDANCE WITH TRADE 6. INDICATED ON DRAWINGS; FABRICATE UNITS SQUARE, TRUE AND FREE FROM DEFECTS. 5. PRACTICE AND MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR THE USE INTENDED. QUALITY WORKMANSHIP AND MATERIALS. PROVIDE IN ACCORDANCE WITH BEST TRADE 4. SEAMLESS CONSTRUCTION WITH NO VISIBLE SEAMS OR JOINTS ON FACES OR VERTICAL 3. 2. FREE FROM SCALE AND PITTING AND OTHER SURFACE DEFECTS, UNLESS OTHERWISE 1. 3. JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL FRAMES TO RETAIN POSITION AND CONTINUOUSLY CHECK ALIGNMENT DURING REQUIREMENTS FOR THE SPECIFIED HARDWARE AND INTENDED USE. THE DRAWINGS. DRAWINGS. EDGES; THICKNESSES AS SCHEDULED ON DRAWINGS. D. MINIMUM 16. GA. FOR INTERIOR FRAMES. C. MINIMUM 22 GA. FOR FACE STIFFENERS. B. 16 GA. FOR EDGE CHANNELS. A. MINIMUM 18. GA. FOR FACE SHEETS OF INTERIOR DOORS. DIVISION 8 - WOOD AND HOLLOW METAL DOORS AND FRAMES MANUFACTURER'S WRITTEN INSTRUCTIONS PRIOR TO INSTALLATION. FOLLOWING MATERIAL BE ACCEPTED. NOTED. AND CURTAIN WALLS. 9. ADJUST SUPPORTS, SPANS OR OTHERWISE FOR INSTALLATION WITHIN SPECIFIED APPLICABLE ASTM STANDARDS AS REFERENCED ABOVE, USING A LASER LEVEL. AS INDICATED. TRUE TO LINE, LEVEL AND PLUM, AND IN ACCORDANCE WITH 8. BLOCKING, BRACING, AND ANCHOR STRIPS. LEAVE READY TO RECEIVE FINISH SECURE TO TRACK. INSTALL HEAD TRACK IN ACCORDANCE WITH DETAILS. INSTALL WITH ASTM STANDARDS. ERECT STUDS ON 16" CENTERS AND 7. 6. BETWEEN LINTELS AND HEADERS IN TOP TRACKS. 5. 4. HEMMED EDGES. HOT DIPPED FINISH WHERE NOTED. 3. 2. 20 GAUGE PROVIDE 16 GAUGE AT DOOR JAMBS AND AT STOREFRONT. ASTM C645-00, HOT DIPPED FINISH WHERE EXPOSED TO MOISTURE NOT LESS THAN 1. 2. PRIMER SHALL BE MADE OR RECOMMENDED BY SEALANT MANUFACTURER FOR THE JOINTS AT INNER SECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES RUBBER SEALING COMPOUND WITH MINIMUM 90% SOLIDS. USE AT ALL INTERIOR ACOUSTICAL SEALANT WHICH SHALL BE NON-HARDENING, NON-DRYING SYNTHETIC SPECIFIC CONDITIONS AND SUBSTRATES. SPECIFICATIONS TTS-1543 OR FS TT-S 230 TYPE "II", CLASS "a". PROVIDE 1. DIVISION 7 - SEALANTS AND CAULKING/ ROOF PATCHING MATERIALS. TOLERANCES. EQUIPMENT, INCLUDING DOOR STOPS. METAL SUPPORT SYSTEM (WALL STUDS) DIVISION 9 - FINISHES 4. REQUIRED FOR COMPLETING BUILT UP ROOFING FLASHING AND ASSOCIATED SHEET METAL WORK AND RELATED ITEMS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. (NOTE: REFER TO DRAWINGS FOR ITEMS APPLICABLE TO THE PROJECT) ALL MATERIALS INCLUDING FELTS, COMPOSITION FLASHING, BITUMEN, ROOF INSULATION, VAPOR RETARDER, (IF ANY), AGGREGATE SURFACING OR OTHER COATING, ETC. IS TO BE COMPATIBLE W/EXIST. ROOFING SYSTEM TO COMPLETE THE PATCHING OF THE EXIST. ROOF 2. PROVIDE TYPE "X" FIRE RETARDANT GYPSUM WALL BOARD PANELS 5/8" THICK, TESTED IN LOCATIONS AS RECOMMENDED BY INDUSTRY STANDARDS AND IN COMPLIANCE WITH 5. FOR CONTROL JOINTS, PROVIDE U.S. GYPSUM #093 OR APPROVED EQUAL. INSTALL RATING, TAPERED AND ROUNDED EDGES AND BE INSTALLED IN ALL WET AREAS AS 4. WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK, QUALIFIED FOR 1- HOUR 3. PROVIDE METAL EDGE AND CORNER BEADS AT ENDS, EDGES AND CORNERS. AND QUALIFIED FOR 1-HOUR RATING, TAPERED AND ROUNDED AT EDGES AS INDICATED 1. PROVIDE GYPSUM WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF EGSHELL FOR ALL INTERIOR FINISHES. SUPPLEMENTED HEREINAFTER AND UPON WRITTEN OWNER APPROVAL. IN GENERAL, USE 13. FINISH INTERIOR SURFACES, AS SCHEDULED ON DRAWINGS, EXCEPT AS MODIFIED AND 12. OTHER PAINT MANUFACTURER'S MAY NOT BE SUBSTITUTED WITHOUT APPROVAL OF SURFACES IN GOOD AND CLEAN CONDITION. PROVIDE FOR MULTIPLE SITE VISITS AS 11. AT COMPLETION, TOUCH-UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL HOLES, CRACKS AND OTHER IMPERFECTIONS WITH PUTTY AND SAND SMOOTH. OF TRIM, PRIME BARE WOOD SCHEDULED TO RECEIVE PAINT FINISH; FINISH NAIL OR PUTTY. IF STAIN HAS BEEN USED, TINT CRACK FILLER TO MATCH; PRIME BACKS AFTER STAIN COAT HAS BEEN APPLIED, FILL CRACKS AND HOLES WITH PLASTIC WOOD READY FOR APPLICATION. SANDPAPER SURFACES OF TRIM SMOOTH AND WIPE CLEAN. THOROUGHLY CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND 10. BACK PRIME ALL EXTERIOR AND INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION. COLOR. SAND ALL WOODWORK BETWEEN COATS TO A SMOOTH SURFACE. SURFACE IMPERFECTIONS WITH PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD PRIMING COAT HAS BEEN APPLIED, THOROUGHLY FILL ALL NAIL HOLES AN OTHER 9. SANDPAPER ALL NEW WOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF. AFTER PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO 8. ALL SURFACES TO BE PAINTED SHALL BE THOROUGHLY CLEANED AND PREPARED FOR CONTRACTOR SHALL FOLLOW MANUFACTURER'S INSTRUCTIONS FOR PROPER APPLICATION MANUFACTURER FOR THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING 7. PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE GYPSUM WALL BOARD INDICATED ON DRAWINGS. REQUIRED FOR TOUCH-UP AND REFINISHING. U.S. GYPSUM STANDARDS. ON DRAWINGS. ARCHITECT. ASTM C36/C36M-01. PREVENT BUILD-UP OF FUMES. OF THE PAINT. ALIGN ALL JOINTS AND CORNERS. REPLACE DAMAGED TILE AT NO ADDITIONAL COST TO OWNER. AREA CLOSED UNTIL TILE IS FIRMLY SET. PROTECT FLOORING FROM DAMAGE. 9. CLOSE AREAS IN WHICH TILE IS BEING PLACED TO TRAFFIC AND OTHER WORK. DEEP APPLICABLE. VARY MORTAR THICKNESS, AS NECESSARY, TO ACCOMMODATE VARIATION OF WORK. CUT TILE AT WALL INTERSECTIONS FOR CONCEALMENT BY BASE WHERE BY OWNER. VERIFY LAYOUT AND CUTS WITH PROJECT MANAGER PRIOR TO COMMENCEMENT BUTTED JOINTS, TO PATTERN INDICATED IN THE DRAWINGS, OR AS SPECIFIED 8. INSTALL TILE TO CONCRETE SUBSTRATE PER TCA STANDARD F113-89 WITH TIGHTLY OLD SEALANTS OR GLAZING COMPOUNDS AND PROTECTIVE COATINGS. METAL SHALL BE MATTER AND CONTAMINANTS SUCH AS GREASE, OIL, DUST, WATER, SURFACE DIRT, 7. CLEAN METAL AND WOOD SURFACES AND CONCRETE FLOORS, REMOVING ALL FOREIGN 4. STOREFRONT GLASS SHALL BE AS REQUIRED FOR THE SIZES AND CONDITIONS 3. GENERAL GLASS SHALL BE q3 IN ACCORDANCE WITH FEDERAL SPECIFICATIONS DD-G- 2. ALL GLASS EDGES SHALL BE GROUND SMOOTH AND POLISHED. THICK, UNLESS OTHERWISE NOTED. ALL GLASS TO BE CLEAR GLASS. 1. PROVIDE TEMPERED GLASS, GRAD "B", STYLE #1, TYPE "1", QUALITY 03, 1/2" USING MATERIALS RECOMMENDED FOR THAT PURPOSE BY THE MANUFACTURER. SURFACES, IN ACCORDANCE WITH THE TIMING RECOMMENDED BY THE MANUFACTURER, 5. UPON COMPLETION, IMMEDIATELY REMOVE ALL SURPLUS ADHESIVE FROM ADJACENT 4. CAREFULLY INSPECT ALL SURFACES TO RECEIVE BASE PRIOR TO INSTALLATION. 3. USE ADHESIVES ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO CONDITIONS. 2. PROVIDE JOB MITERED INSIDE AND OUTSIDE CORNERS PER DRAWING DETAILS FOR ALL 1. INSTALL TILE BASE IN TOILETS AS SCHEDULED. VERIFY WITH HEALTH CODE REQUIREMENTS. 12. DAMP CURE PER MORTAR AND GROUT MANUFACTURER'S RECOMMENDATIONS. 11. GROUT FLUSH WITH TILE EDGES. WIPE TILES WITH CHEESE CLOTH INSTEAD OF WITH DOW CORNING 795 SILICONE BUILDING SEALANT. BEADS AT 6" ON CENTER 10. INSTALL TILE TO WOOD SURFACES AND ALUMINUM GLAZING CHANNEL AND METAL BASE 15. UPON COMPLETION, REMOVE ALL EXCESS SEALANT AND MATERIALS FROM SURFACES; SHALL BE LEVEL, FLUSH SQUARE PLUMB AND IN ALIGNMENT WITH OTHER WORK. 14. SET ALL EXTRUSIONS IN CORRECT LOCATIONS AS SHOWN IN THE DETAILS. THEY REQUIRED TO POSITION AGAINST FIXED STOPS AND FRAME BARS. SIDES, INDOORS AND OUT, IN ACCORDANCE WITH FGMA RECOMMENDATIONS. SHIM AS 13. CENTER GLASS IN RABBETS AND POSITION SO AS TO MAINTAIN CLEARANCES ON ALL ARE CLEAN, DRY AND READY TO RECEIVE GLAZING MATERIALS. REMOVE ALL CLEARANCES ARE SUFFICIENT TO PREVENT "POINT LOADING", AND THAT SURFACES 12. VERIFY THAT FRAMES TO RECEIVE GLAZING ARE SQUARE AND TRUE, THAT PERIMETER 11. INSTALL IN ACCORDANCE WITH FGMA RECOMMENDATIONS UNLESS NOTED OTHERWISE. 10. ALL EDGES, DRILLED HOLES AND NOTCHES SHALL BE FACTORY CUT AND/OR FACTORY GLASS SHALL HAVE A 1/4" VERTICAL CLEAR SPACE BETWEEN GLASS PANELS. USE ONLY IF REQUIRED BY LOCAL BUILDING CODES, OTHERWISE ALL STOREFRONT 9. USE SILICONE SEALANT DOW #795 OR GE SILPRUF, CLEAR, OR APPROVED EQUAL. 8. PROVIDE NON-SHRINKING ELASTROMERIC TAPER WHERE REQUIRED. 7. PROVIDE STANDARD PREFORMED GLAZING TAPE, STANLOCKE 400, TRIMCO 440, OR 6. PROVIDE CLIPS ON NON-CORROSIVE METAL WITH ROUNDED EDGES DESIGNED FOR RESILIENT ACCESSORIES DESIGNED FOR POSITIONING GLASS IN RABBETS. 5. PROVIDE RESILIENT NEOPRENE BLOCKS 70 TO 90 SHORE A DUROMETER HARDNESS AND SHALL BE FACTORY MILL FINISH. REFER TO ELEVATION PLAN FOR TYPE OF FINISH DETAILED FRAME SECTION SHALL BE EXPOSED WHERE INDICATED. FRAME FINISH CONTACT BLOCKS, NOT GLASS. WASH AND CLEAN ALL GLASS FRAMING MEMBERS. PROTECTIVE COATING FROM FRAMING SURFACES. FORMED, TOUCH-UP "RAW" EDGES TO MATCH FRAME. APPROVED. COLOR. CLEANED BY MECHANICAL OR SOLVENT PROCEDURES. 451 AND FGMA GLAZING MANUAL. REPAIR DAMAGED SURFACES PRIOR TO INSTALLATION. GLASS AND GLAZING (EXISTING) WHICH IT IS APPLIED. BASE IN THE TILE THICKNESS. MAXIMUM. SPONGE. 10. PROVIDE FINAL FINISH THAT IS SMOOTH, WITHOUT DIVOTS, BUMPS, BOWS OR ANY ANGLES. FIRE TAPE PENETRATIONS AT DEMISING WALLS, CORRIDOR ENVELOPE AND FILLING AND TAPER FLUSH WITH SURFACE; NO SECOND COAT REQUIRED AT INTERIOR COAT. AFTER TAPING AND EMBEDDING COMPOUND IS DRY, APPLY SECOND COAT APPLY EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT; APPLY SKIM 9. APPLY PRE-FILL COMPOUND TO JOINT IN ACCORDANCE WITH INDUSTRY STANDARDS. SULFIDE SEALANT; WHERE UNEXPOSED, PROVIDE ACOUSTIC SEALANT. PROTRUSIONS THROUGH WALL BOARD. WHERE SEALANT IS EXPOSED, PROVIDE POLY- ADJACENT CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER 8. APPLY CONTINUOUS BEAD OF SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING CONSTRUCTION INCLUDING ACCESS DOORS AND PANELS. METHODS REQUIRED FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD 7. PROVIDE ALL INCIDENTAL AND ACCESSORY MATERIALS, TOOLS, EQUIPMENT, AND BOARD TO METAL FRAMING, AND TYPE 'S' PAN HEAD SCREWS FOR ATTACHMENT OF INDICATED, PROVIDE TYPE 'S' BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL 6. PROVIDE FASTENERS IN ACCORDANCE WITH ASTM C1002-01; UNLESS OTHERWISE NOTED OR 6. SET AND GROUT TILE WHEN AMBIENT TEMPERATURE IS AT LEAST 50 AND RISING. TO DETERMINE THE REQUIRED EXTENT OF SUBFLOOR PREPARATION. 4. DO NOT COMMENCE INSTALLATION UNTIL SUBSTRATE HAS BEEN MADE SUITABLE FOR 3. ALL INSTALLATION SHALL CONFORM TO THE LATEST APPLICABLE TILE COUNCIL OF 2. INSTALLERS MUST BE SPECIALISTS WITH A MINIMUM OF TWO (2) YEARS EXPERIENCE. BY MANUFACTURER AND IN ACCORDANCE WITH INDUSTRY STANDARDS. FRAMING TO DOOR FRAMES. OTHER RATED ASSEMBLIES. OTHER SURFACE BLEMISH, READY TO RECEIVE PAINT. AMERICA AND ANSI STANDARDS. 1. INSTALL TILE IN AREAS INDICATED . USE ADHESIVES AND APPLY ONLY AS RECOMMENDED TILE INSTALLATION. TILE 5. PROVIDE "OWENS CORNING" SOUND ATTENUATION BATT INSULATION AT ALL PERIMETER WALLS OR TOILET ROOMS FULL HEIGHT OF WALLS. INSULATION SHALL BE 3 1/2" THICK FRICTION FIT INSTALLATION FOR 16" STUD SPACING. CUT AS REQUIRED FOR UTILITIES IN WALLS. 11. IN ADDTION TO OTHER STIPULATED REQUIREMENTS FOR CLEANING, COMPLETELY REMOVE FINGER PRINTS AND TRACES OF SOIL FROM THE SURFACES OF EXPOSED PORTIONS, USING ONLY THOSE CLEANING MATERIALS RECOMMENDED FOR THE PURPOSE BY THE MANUFACTURER OF THE MATERIAL BEING CLEANED. TOLERANCE OF 1 IN 1000. SUSPENDED CEILING SYSTEM 1. PROVIDE HOLD DOWN CLIPS WITH UL CLASSIFICATION LABEL. 2. WORK INCLUDED: PROVIDE SUSPENDED CEILING SYSTEM WHERE SHOWN ON THE DRAWINGS. 3. USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND 4. DO NOT BEGIN INSTALLATION IN ANY AREA UNTIL SUFFICIENT MATERIALS ARE ON THE 5. PROVIDE THE MANUFACTURER'S HEAVY DUTY SUSPENSION SYSTEM, COMPLYING WITH 6. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE 7. EXAMINE THE AREA AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE 8. EXCEPT AS MODIFIED BY REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, 9. PROVIDE LATERAL BRACING AS REQUIRED BY PERTINENT CODES AND REGULATIONS. SECURE 10. MAKE ALL FINISHED SURFACES LEVEL, OR TRUE TO PLANE WHERE PLANE IS DESIGNED TO REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, AND AS APPROVED AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR SUBJECT TO THE APPROVAL PERFORMED CORRECT CONDITIONS ARE DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. INSTALLATION RECOMMENDATIONS AS APPROVED BY THE ARCHITECT. INSTALL THE WORK OF THIS SECTION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S LATERAL BRACING TO STRUCTURAL MEMBERS. SECURE AT RIGHT ANGLES TO THE DIRECTION OF THE PARTITION AND FOUR-WAYS IN LARGE CEILING AREAS. BE OTHER THAN LEVEL, WITHIN A TOLERANNCE OF 1 IN 1000, AND STRAIGHT WITHIN A INSTALLATION, AS SELECTED OF THE ARCHITECT. BY THE ARCHITECT. AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE JOBSITE TO COMPLETE THE WORK OF THIS SECTION IN THAT AREA. OF THE WORK OF THIS SECTION. SUSPENSION SYSTEM - AS REQUIRED TO SUPPORT GYPSUM BOARD PANELS, FIXTURES AND 12. MATERIALS OTHER COMPONENTS AS INDICATED, INCLUDING ANCHORAGES, HANGERS, RUNNERS, CROSS RUNNERS, SPLINES, CLIPS, MOLDING, FASTENERS AND OTHER MEMBERS, DEVICES AND ACCESSORIES. COMPLY WITH ASTM C635. 2' X 4' GRID/2'X2' GRID. ENAMEL EDGE MOLDING - METAL CHANNEL TYPE WITH SINGLE FLANGE EXPOSED. HUNG OR INDIRECT FROM DUCTS, PIPES OR CONDUIT. EXPOSED FINISH - WHITE BAKED HANGER WIRE - NOT LESS THAN 12 GAUGE (0.106") GALVANIZED STEEL. TYPE - DIRECT GRID SYSTEM "USG" TYPE DX 15/16" EDGE. CEILING PANELS - 2' x 4' VINYL CLAD GYPSUM CEILING TILE(PREP AND RESTROOMS) 1. FIBER REINFORCED PANELS (FRP) CORRODE. PROVIDE ALL TRIM AND ACCESSORIES AS REQUIRED FOR A COMPLETE THAN 25. ALL PANELS SHALL BE MOISTURE RESISTANT AND SHALL NOT RUST OR INSTALLATION AS INDICATED AND SPECIFIED HEREIN. COLOR OF PANELS, TRIM AND ACCESSORIES SHALL BE WHITE. 2. PREFINISHED PANEL AS SCHEDULED. 3. 4. WITH V-NOTCH SPREADER. MITER CUT MOLDINGS AND TRIM PIECES AT CORNERS AND INTERSECTIONS AS REQUIRED TO PROVIDE SMOOTH TRANSITION. 5. IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LEFT FREE FROM DEFECTS, COMPONENTS THAT ARE DAMAGED OR IMPROPERLY INSTALLED SHALL BE REMOVED AND REPLACED WITHOUT ADDITIONAL COST TO THE OWNER. 2. UPON COMPLETION OF PAINT APPLICATION CAREFULLY REMOVE STENCIL FROM 1. OWNER TO SUPPLY STENCIL FOR SUPER SEAL LOGO. CONTRACTOR TO COORDINATE EXACT PLACEMENT OF LOGO WITH DRAWINGS AND JIMMY JOHN'S CONSTRUCTION MANAGER PRIOR TO APPLICATION. CONTRACTOR TO APPLY STENCIL TO BRICK SURFACE TAKING CARE TO PRESS FIRMLY INTO ANY JOINTS OR TEXTURE SO AS NOT TO ALLOW FOR ANY OVERSPRAY BEHIND STENCIL DURING PAINT APPLICATION. ONCE STENCIL HAS BEEN PLACED CONTRACTOR SHALL APPLY PAINT TO EXTENT INDICATED ON DRAWINGS, 3. IN AN EFFORT TO PROVIDE AN AGED APPEARANCE, CONTRACTOR SHALL WIRE BRUSH ENTIRE SUPER SEAL LOGO BEING CAREFUL NOT TO COMPLETELY REMOVE NEWLY PAINTED FINISH. CONTRACTOR MUST NOTIFY JIMMY JOHN'S CONSTRUCTION MANAGER ONE WEEK PRIOR TO THIS FINAL STEP TO INSURE PROPER APPEARANCE. PAINTING - SPECIALTY (EXTERIOR SUPER SEAL) USING SPRAY EQUIPMENT. THE FOLLOWING MATERIALS SHALL BE LEFT AT JOBSITE. THEY SHALL BE TAKEN THE OWNER OR THE OWNER'S SUBCONTRACTORS MAY OCCUPY PORTIONS OF THE PROJECT ALL DIMENSIONS AND FINISHES SHALL BE VERIFIED AND COORDINATED WITH ALLOWABLE TOLERANCES - UNLESS OTHERWISE NOTED OR INDICATED. THE PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTABLE TRADE PRACTICE TO INSURE COORDINATE BLOCKING REQUIREMENTS WITH ADJACENT OR RELATED TRADES, REPAIR PROPERTY DAMAGE BY THE INSTALLERS TO A LIKE NEW CONDITION OR WHERE REQUESTED BY THE OWNER TO CERTIFY CONFORMANCE TO TRADE STANDARDS OR PROVIDE SECURITY OF THE WORK, INCLUDING TOOLS AND UNINSTALLED MATERIALS. MAINTAIN AN ACTIVE FIRE EXTINGUISHER AT THE PROJECT. DO NOT USE MATERIAL OR EQUIPMENT FOR ANY PURPOSE OTHER THAN THAT FOR WHICH WHEN THE PROJECT REQUIREMENTS REQUIRE THAT THE INSTALLATION OF WORK SHALL ALL PRODUCTS AND EQUIPMENT SHALL BE DELIVERED IN UNDAMAGED CONDITION AND NOTIFY THE OWNER WHEN THE WORK IS SUBSTANTIALLY COMPLETE AND READY FOR PROVIDE FINAL CLEAN-UP AND DAMAGE REPAIR AT THE PROJECT CONCLUSION. LEAVE PROVIDE NON-SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL AND SOUND ATTENUATION BATT INSULATION SOUND ATTENUATION BATT INSULATION ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH PROVIDE BACKING MATERIAL BY DOW "ETHAFOAM" OR APPROVED EQUAL. APPLY FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SCAFFOLDING PROVIDE HOLLOW METAL DOOR AS REQUIRED ON PLANS CONSTRUCTED WITH THE PROVIDE WELDED METAL DOOR FRAMES AT ALL DOORS, AS DETAILED PROVIDE CUSTOM MADE WELDED UNITS WITH INTEGRAL TRIM; SIZES AND SHAPES AS FACE STIFFENERS, EDGES AND HARDWARE REINFORCEMENT SHALL BE THE HIGHEST PROVIDE DOORS OF SIZES AND TYPES INDICATED ON DRAWINGS, FULLY WELDED INSTALL FRAMES IN ACCURATE LOCATIONS AS INDICATED ON DRAWINGS. INSTALL AFTER FABRICATION, DRESS, FILL AND SAND EXPOSED SURFACES, BODY-PUTTY HOLES HARDWARE REINFORCEMENT AND ANCHORS (ERECTION, FLOOR AND JAMB) SHALL BE AS PREPARE DOORS FOR FINISH HARDWARE. OBTAIN TEMPLATES FROM HARDWARE INSTALL WOOD DOORS, FRAMES, AND TRIM. SIZES AND THICKNESS AS SCHEDULED ON HANG DOORS AS SCHEDULED ON DRAWINGS, IN ACCURATE LOCATIONS WITH 1/8" PROVIDE CHANNEL-SHAPED ROLL FORMED SHEET STEEL MEMBERS CONFORMING WITH PROVIDE BLOCKING AND FRAMING FOR ALL WALL MOUNTED FINISH HARDWARE AND PROVIDE JACK STUDS BETWEEN BOTTOM TRACK AND WINDOW AND/OR RELIEF SILLS INTERIOR WALL CONNECTIONS TO EXIST. STRUCTURE ABOVE REFER TO DRAWINGS. PROVIDE ROLL HAT-SHAPED CHANNELS MINIMUM 20 GAUGE, 7/8" DEEP WITH 1/2" PROVIDE COLD, ROLLED STEEL CHANNELS NOT LESS THAN 16 GAUGE. PROVIDE KICK AS SHOWN FOR WALL STUDS,CEILING MEMBER, DRAFT OR SMOKE STOPS ERECT ALL COMPONENTS FOR CEILING AND SOFFIT FRAMING IN ACCURATE LOCATIONS SET FLOOR TRACKS IN ACCURATE LOCATIONS AND SECURELY ANCHOR IN ACCORDANCE ALL PANELS SHALL HAVE A CLASS 1 FLAME - SPREAD CLASSIFICATION INDEX OF LESS FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES FOR ALL PANELS SHALL BE INSTALLED IN A VERTICAL POSITION IN FULL LENGTH UNITS. APPLY RECOMMENDED ADHESIVE TO BACK OF PANEL TO PROVIDE 100% COVERAGE UPON COMPLETION OF WORK, SURFACES OF PANELS AND COMPONENTS SHALL BE CLEANED 1. SQUARE FOOT CALCULATIONS AS NOTED ON THE TITLE SHEET. CONTRACT WILL INCLUDE CONSTRUCTING WALLS AND CEILINGS FINISHES, DETAILS & SPECIFICATIONS. SECURE AND PAY FOR GOVERNMENT FEES, LICENSES AND PERMITS. FOOTAGES. NOTIFY THE OWNER AND ARCHITECT OF COMPLIANCE OR DISCREPANCIES, COMPARING THOSE DISCREPANCIES TO THE NUMBERS ON THE TITLE SHEET. DAMAGE DURING THE CONSTRUCTION PROCESS, AND SHALL CLEAN UP AFTER THEMSELVES AT THE END OF EACH WORKING DAY. DISPOSED OF EACH DAY. NO RUBBISH SHALL BE LEFT IN THE PREMISES AFTER WORK RESPONSIBLE FOR REVIEWING THEIR RESPECTIVE REQUIREMENTS AND COORDINAT- ING THEIR HIDDEN OR EXPOSED WORK WITH OTHER RELATED TRADES. ASSURE EFFICIENT AND ORDERLY INSTALLATION. PROVIDE ACCOMMODATION FOR ITEMS INSTALLED AT A LATER DATE. VERIFY THAT CHARACTERISTICS OF ELEMENTS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK OF VARIOUS SECTIONS WHICH HAVE INTERDEPENDENT RESPONSIBILITIES FOR INSTALL- ING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT.COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK AND FIRE SPRINKLER SYSTEM WHICH ARE INDICATED, DETAILED, OR IMPLIED EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK, INCLUDING PERMITS. UTILITIES SHALL BE PROVIDED BY OWNER. ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD AND THE TENANT. VERIFY AND COORDINATE WITH THE TENANT FOR ANY ADDITIONAL REQUIREMENTS. IMMEDIATELY AFTER RECEIPT OF NOTICE TO PROCEED FOR USE IN CONVENIENCE OF ALL THOSE ENGAGED IN THE PROJECT WORK. SUCH AREAS CLEAN AND FREE OF CONSTRUCTION MATERIALS AND DEBRIS. FAILURE TO MAINTAIN CLEAN STOREFRONT WILL RESULT IN BUILDING MANAGEMENT HAVING SUCH MATERIALS AND DEBRIS REMOVED AND ALL CHARGES FOR MAINTENANCE WILL JOHN'S REVIEWING ALL SCHEDULED ACTIVITIES AT OUTSET OF CONSTRUCTION. THE WORK INCLUDES NEW TENANT IMPROVEMENTS IN AN EXISTING SPACE, PER 2. PRIOR TO BEGINNING THE WORK, VERIFY ALL EXISTING DIMENSIONS AND SQUARE3. CONTRACTORS SHALL TAKE CARE TO PROTECT ADJACENT AREAS FROM DUST AND ALL RUBBISH AND TRASH SHALL BE REMOVED FROM THE PREMISES AND PROPERLY 4. 5. IS COMPLETED EACH DAY. ALL DRAWINGS HEREIN CREATE AN ENTIRE PACKAGE. ALL TRADES SHALL BE6. COORDINATE ALL WORK OF THE VARIOUS TRADES AND SUBCONTRACTORS TO7. UNLESS SPECIFICALLY NOTED, PROVIDE AND PAY FOR LABOR, MATERIALS AND8. DIAGRAMMATICALLY ON DRAWINGS. GENERAL CONTRACTOR SHALL PURCHASE AND MAINTAIN INSURANCE COVERAGE IN9. FURNISH ALL REQUIRED TEMPORARY FACILITIES AND ALL TEMPORARY UTILITIES10. ALL CONTRACTORS MUST STAY BEHIND THE BARRIERS AND MAINTAIN ACCESS TO11. BE BILLED TO GENERAL CONTRACTOR. COORDINATE ALL CONSTRUCTION AND SCHEDULING WITH THE LANDLORD/JIMMY12. DIVISION 1 - GENERAL REQUIREMENTS ALL FIXTURES RECESSED IN THE CONCRETE FLOOR (I.E. GREASE TRAP, FLOOR DRAINS, FLOOR SINKS, ETC.) ARE TO HAVE THEIR FINISHED TOP LEVEL WITH THE TOP OF THE FINISHED FLOORING (I.E. TILE) AND NOT THE CONCRETE SLAB UNLESS OTHERWISE NOTED. ALL CLEANOUTS, WATER LINES, PIPES THRU WALLS, ETC. ARE TO BE A MINIMUM OF 10" TO BOTTOM AFF AND CONSISTENT THROUGHOUT ENTIRE SPACE. ALL GRILLE COLLARS SHALL BE ATTACHED TO DUCTWORK WITH POP RIVETS WITH A FINISHED THE SUPPORTS FROM THE STRUCTURE ARE TO BE A MINIMUM OF 3/8" THREADED ROD ALL THREADED ROD USED TO SUPPORT THE HOOD IS TO BE COVERED WITH PVC (SUPPLIED AND INSTALLED BY SUBCONTRACTOR) TO CREATE A WASHABLE SURFACE ALL DUCT JOINTS SHALL BE SEALED USING DUCT SEAL AS MANUFACTURED BY UNITED SHEET METAL, OR EQUAL. RED DUCT TAPE SHALL NO BE ACCEPTED. ALL EXPOSED SPIRAL DUCT SHALL BE SINGLE WALL UNINSULATED, WITH DUCT BOOTS ATTACHED COVERS ON THE THERMOSTAT ARE TO BE EQUIPPED WITH AND ABLE TO BE LOCKABLE SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS (INCLUDING RESTROOM FIXTURES). BLOCKING IS TO BE FIRE RATED IF REQUIRED THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISIBLE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. THE OUTLET MOUNTED BELOW THE SLICER TABLE MUST BE A LEVITON MODEL BY LOCAL CODES DETAILED SPEC FOUND ON E-3 SHEET - - ELECTRIC: - FILLET OF ELASTOMER SEAL AT JUNCTION AT A 45 DEGREE ANGLE DOWNWARD OFF OF DUCT. - - - - HVAC: - - REPRESENTATIVE OF GC. - - ALL FLOOR DRAINS, FUNNEL DRAINS, CLEAN OUTS, FLOOR SINKS ETC ARE TO BE CAST IRON PROVIDE & INSTALL ALL BLOCKING REQUIRED TO MOUNT SINKS, FAUCETS, ETC. ALL BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. BRASS OR PLASTIC AS SPECIFIED WITHIN THE CONTRACT DOCUMENTS. - PLUMBING: - 4. FINISH WORK SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM CLEAN. WHERE HIGH GLOSS ENAMEL IS USED, LIGHTLY SAND UNDERCOAT TO OBTAIN RUNS. MAKE ENDS OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND APPLY NO FINISH MATERIAL UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE PAINTED OR STAINED IS FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. 3. PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE COMMENCING THE WORK. STORE, CLEAN, AND REPLACE UPON COMPLETION. ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTING, AND FASTENINGS PRIOR TO ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSSERS, GRILLES, WORK. REPAIR ANY DAMAGE CAUSED BY THE WORK OF THIS SECTION. REMOVE 2. PROTECT WORK OF OTHER TRADES FROM DAMAGE AND DEFACEMENT CAUSED BY THIS FINISH, NON-MECHANICAL ROOM SPACES. NO PAINTING IS REQUIRED FOR INSULATED PIPING, EXCEPT WHERE EXPOSED IN ALTERATIONS OCCUR OR WHERE SCHEDULED. PAINT GRILLES AND DIFFUSSERS. STAINLESS STEEL; INTERIOR OR EXTERIOR OF EXISTING BUILDING, EXCEPT WHERE NON-FERROUS METAL UNLESS SPECIFICALLY MENTIONED IN THE FINISH SCHEDULE; AS MAY BE SPECIFIED HEREINAFTER; PUTTY AND/OR SEALANT AT ALUMINUM WINDOWS; DRAWINGS OR AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR 1. PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON PAINTING NO PAINT FINISH IS REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT A SMOOTH FINISH COAT. SATISFACTORY. MANUFACTURER'S LABEL AND SHOWING PAINT TYPE, SHEEN AND COLOR. 6. DELIVER ALL PAINT TO JOBSITE IN UNOPENED CONTAINERS BEARING THE COATS FINAL COLOR COAT TO ACHIEVE UNIFORM FINISH. 5. PROVIDE ALL NEWLY PAINTED SURFACES WITH (1) COAT TINTED PRIMER AND (2) THE JIMMY JOHN'S BUILD OUT MANUAL IS TO BE USED IN CONJUNCTION WITH BLUEPRINT DRAWINGS. ANY DISCREPANCIES MUST BE BROUGHT UP TO THE JIMMY JOHNS CONSTRUCTION DEPARTMENT. JIMMY JOHN'S CORPORATE NOTES: ALL SUPPLY LINES AND DRAINS MUST BE SECURED AND FREE FROM MOVEMENT AT PENETRATIONS - 5. REVIEW ALL AREAS TO RECEIVE TILE FLOORING (PRIOR TO SUBMITTING BID) APPROXIMATELY, 1/2" ABOVE CONCRETE. IF THE FLOOR IS NOT CONCRETE, VERIFY WITH ONSITE COORDINATE THIS WORK WITH OTHER TRADES INVOLVED TO AVOID DELAYS AND TO INSURE A SATISFACTORY AND WATERTIGHT INSTALLATION. INSTALL ALL REQUIRED MATERIALS IN A PROPER MANNER TO INSURE AN AIRTIGHT, WATERTIGHT, AND WEATHERPROOF INSTALLATION. 28.THE CONTRACTOR SHALL OBTAIN ALL BUILDING PERMITS, APPROVALS, CALLS FOR INSPECTIONS, ETC. THE OWNER SHALL REIMBURSE THE CONTRACTOR FOR THE AMOUNT OF FEES PAID FOR THIS. 29.TEMPORARY SERVICES: ANY REQUIRED TEMPORARY ELECTRICAL POWER AND LIGHTING SYSTEMS SHALL BE FURNISHED, INSTALLED AND REMOVED BY THE CONTRACTOR. 30.CONTRACTOR SHALL NOT UNDER ANY CIRCUMSTANCES, ALTER THE CONSTRUCTION DOCUMENTS. IF SITE CONDITIONS REQUIRE MODIFICATIONS TO THE PLANS, ALL MODIFICATIONS SHALL BE SUBMITTED TO THE ARCHITECT AND APPROVED PRIOR TO PROCEEDING WITH THOSE MODIFICATIONS. CONTRACTOR SHALL ASSUME LIABILITY FOR ANY MODIFICATIONS TO PLANS WHICH ARE NOT APPROVED IN WRITTING BY THE ARCHITECT. CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE, ANY ITEMS NECCESSART TO BRING THE STORE INTO COMPLICANCE WITH THE DRAWINGS. MANUFACTURER'S LATEST WRITTEN AND RECOMMENDED DIRECTIONS. SHALL BE TWO PARTS - MORTAR MIX AND LATEX BINDER MIX AND INSTALL PER 2. ANY HOLES GREATER THAN 1/2". AND LEVELING JOINTS AND CRACKS; AND FILLING ABANDONED ELECTRICAL BOXES AND 1. DIVISION 3 - CONCRETE REPAIR AND REPLACEMENT ENCOUNTERED; DISPOSE OF BY SAFE MEANS TO PROTECT HEALTH OF WORKERS AND 11. 10. 9. OF THE BUILDING, IN ACCORDANCE WITH GUIDELINES AND STIPULATIONS OF LOCAL PREVENT WEATHER DAMAGE OR SPREAD OF DUST, FUMES AND SMOKE TO OTHER PARTS 8. ERECT AND MAINTAIN WEATHERPROOF AND DUSTPROOF CLOSURES AND PARTITIONS TO DEMOLISHED IMMEDIATELY FROM THE SITE. STORE IN A SECURE LOCATION. REMOVE DEBRIS, REFUSE AND MATERIALS BEING 7. VALVE AND SMOKE ALARM PRIOR TO COMMENCING WORK; COORDINATE REQUIRED OF DISCONNECTED SERVICES. WHERE APPLICABLE, LOCATE SPRINKLER SHUT-OFF WITHIN AREAS AFFECTED BY DEMOLITION. PLACE MARKERS TO INDICATE LOCATION 6. SUCH MOVEMENT, SETTLEMENT DAMAGE OR INJURY. DETERMINED BY G.C. ENLISTED STRUCTURAL ENGINEER. ASSUME LIABILITY FOR AND SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE, AS 5. 2. PUBLIC. JURISDICTION. 1. DIVISION 2 - DEMOLITION / BUILDING ALTERATIONS C. ALL RUNNING TRIM ONE (1) PIECE UP TO 10' - 0". MATCH GRAIN AND B. MITER CASINGS, MOLDING, BASE AND STOREFRONT LAMINATED OR PAINTED MDF PANELS. 10. 9. 8. 7. A. INSTALL ALL MATERIAL WITH TIGHT JOINTS. CONSIDERATIONS AND REQUIREMENTS: SOLVENT AND CLEANING PROCEDURES. COLOR PIECE-TO PIECE. REPLACE DAMAGED SURFACES. APPLICATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT 5. 4. 3. 2. PRINTED APPLICATION INSTRUCTIONS. 6. NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS. FOR ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS OR FURRING. LOCAL CODE OR APPROVED BY ARCHITECT. CONDITI0N FOR INSTALLATION. DIVISION 6 - WOOD AND PLASTICS DIVISION 4 - UNIT MASONRY AUTHORITIES & LANDLORD. MODIFICATION WITH LANDLORD. 1. MILL NUMBER OR NAME, GRADE OR LUMBER SPECIES OR SPECIES GROUPING B. ALL LUMBER IS TO BE GRADE STAMPED AND IS TO CONTAIN GRADING AGENCY, COMBINATION DESIGNATION, RULES UNDER WHICH GRADED, WHERE APPLICABLE. WITHOUT SPLITTING WOOD, FASTEN PANEL PRODUCTS TO ALLOW FOR EXPANSION SIDE WILL BE EXPOSED TO VIEW OR RECEIVE FINISH MATERIALS. INSTALL FASTENERS USING FASTENERS OF SIZE THAT WILL NOT PENETRATE MEMBERS WHERE OPPOSITE E. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES AND SUPPORTING MEMBERS AT JOINTS UNLESS OTHERWISE INDICATED. ACCESSORIES, AND ELSEWHERE AS REQUIRED. MEMBERS. PROVIDE BLOCKING WHERE REQUIRED FOR ANCHORAGE OF CASE WORK, WOOD BLOCKING NOT LESS THAN 2" THICK, IF NOT BLOCKED BY OTHER FRAMING STRUCTURAL MEMBERS BETWEEN SUPPORTS. FIRESTOP CONCEALED SPACES WITH F. PROVIDE WOOD FRAMING MEMBERS OF SIZE AND SPACING INDICATED. DO NOT SPLICE PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE. PROVIDE AND PLACE BRACING ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES CAREFULLY REMOVE MATERIALS AND EQUIPMENT WHICH ARE INTENDED TO BE REUSED. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING REMOVE FROM SITE CONTAMINATED, VERMIN INFESTED OR DANGEROUS MATERIALS REPAIR ALL DEMOLITION IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER. WORK INCLUDES PATCHED, DEMOLISHED SLAB AND CERAMIC TILE, IF ANY; FILLING USE RAECO-LITH "r-35" AS UNDERLAYMENT FOR PATCHING OR APPROVED EQUAL MIX ROUGH CARPENTRY USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE "S" TRIM HEAD SCREWS PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES AND QUANTITIES REQUIRED BY INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND 1" USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE FOLLOWING FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION. DRAWINGS AND SPECIFICATIONS APPLY TO THIS WORK. 1. RELATED DOCUMENTS PROTECT WOOD FLOOR FROM MOISTURE. 2. JOB CONDITIONS ALL MASONRY UNITS SHALL BE REPAIRED, REPOINTED AND CLEANED BEFORE 3. REPAIR, POINTING AND CLEANING ACCEPTANCE. USE COMMERCIAL CLEANING MATERIAL "SURE KLEAN 600" DETERGENT GENERAL-PURPOSE CLEANER FOR BRICK, APPLY PER MANUFACTURERS PRINTED SPECIFICATIONS. DRY BRUSH AT END OF EACH DAYS WORK. MFG. - GLEN-GERY BRICK CALEDONIA PLANT DRAWINGS AND SPECIFICATIONS APPLY TO THIS WORK. 1. RELATED DOCUMENTS 5692 RINKER ROAD CALEDONIA, OH 43314 P.O. BOX 398 (419) 845-3321 STANDARDS A PAPERCUT FINISH THAT MEETS ASTM C1088, GRADE EXTERIOR, TYPE TBS SIZE - MODULAR (1/2" X 2 1/4" X 7 5/8") STRETCHER AND CORNER UNITS WITH L/360 AND, PREFERABLY, LESS THAN L/600. IF THE WALLS ARE WET, THE THE WALL SYSTEM MUST BE RIGID. DEFLECTION MUST NOT BE GREATER THAN APPLICATION (TCA W242) - ADHESIVE THIN SET AS RECOMMENDED BY SUPPLIER. SHOULD BE SECURELY ANCHORED. REMOVE ALL WALLPAPER, LOOSE PASTE SOURCE OF THE WATER MUST BE DISCOVERED AND ELIMINATED. WALLBOARD WALLS TO REMOVE DIRT AND DUST. REPAIR ANY DAMAGED AREAS. OR PAINT AND LAMINATES. SAND PAINTED OR GLOSSY SURFACES. WASH USED IN 20 TO 30 MINUTES OR WHILE ADHESIVE IS STILL WET AND TACKY. A PUTTY KNIFE. DO NOT APPLY MORE ADHESIVE ON THE WALL THAN CAN BE WITH A 5/32" V-NOTCHED TROWEL. SMOOTH ANY PRONOUNCED RIDGES WITH ADHESIVE AND THE MORTAR FOR MIXING AND CURING TIMES. APPLY ADHESIVE FOLLOW THE DIRECTIONS PROVIDED BY THE MANUFACTURERS OF BOTH THE ALLOW ADHESIVE TO CURE PRIOR TO POINTING THE BRICKS. ADHESIVE SO THAT THERE ARE NO VOIDS BETWEEN THE BRICKS AND THE WALL. BEATING BLOCK OR RUBBER MALLET. ALL EDGES MUST BE SEALED WITH DIRT FROM BRICK FACES. JOINTS MUST BE FREE OF DIRT, DEBRIS OR SPACERS. SPONGE WIPE DUST AND RECOMMENDED CLEANING MANUFACTURER'S INSTRUCTIONS. DO NOT SATURATE THE SURFACE OR SMEAR DUE TO COLOR AND TEXTURE. REMOVE OTHER MORTARS ACCORDING TO CLEANING PROCEDURES AND SOLUTIONS" FOR THIN BRICKS. PROCEDURES VARY REMOVE CEMENTITIOUS MORTARS ACCORDING TO GLEN-GERY'S "RECOMMENDED CLEANING MUCH EASIER. SMEARING GROUT ON THE FACES OF THE THIN BRICKS. CLEANING IS MUCH EASIER IF CARE IS TAKEN DURING APPLICATION TO AVOID THE MORTAR. EXISTING BRICK (NOT USED) REAL BRICK - THIN BRICK SPACE BRICKS 1/4" APART. BEAT THE BRICKS FIRMLY INTO POSITION WITH A FINISHES TO BE FIRE RETARDANT TREATED UNLESS NOTED OTHERWISE. L. K. I. H. F. D. BE USED FOR ALL WOOD FRAMING MEMBERS AND BLOCKING. EXPOSED WOOD FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS. J. G. SINK AND PUTTY IN FINISH WOOD SURFACES. E. WHERE SCREWS DO NOT SHOW. NON-COMB. FIRE TREATED WOOD BEARING FACTORY IMPREGNATED STAMP SHALL INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FINISH EXPOSED SURFACES SMOOTH, FREE FROM TOOL AND MACHINE MARKS. SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR EASE ALL EXPOSED WOOD EDGES 1/8" MINIMUM RADIUS. ALL MEMBERS AND LINES LEVEL AND PLUMB. SET FASTENERS FOR PUTTYING. WHERE SCREW ATTACHMENT REQUIRED, SPACE SCREWS AT EQUAL INTERVALS; ALL MORTAR JOINTS SHOULD BE SPACED AT 1/4". WATER MAY BE USED TO REMOVE MUCH OF THE MORTAR BEFORE IT HAS SET. THE WORK MAY INCLUDE DEMOLITION OF EXISTING CONSTRUCTION, REMOVAL OF VARIOUS ITEMS OF EQUIPMENT AND CONSTRUCTION, AND THE CUTTING OR ALTERATION OF EXISTING CONSTRUCTION AS SHOWN. NOTED OR IMPLIED ON THE DRAWINGS. CONTRACTOR SHALL DETERMINE AND INVENTORY ALL NECESSARY DEMOLITION AND ALTERATION OF ITEMS TO PROVIDE FOR A COMPLETE INSTALLATION OF NEW WORK. ALL COSTS OF REMOVAL REPAIR OR REPLACEMENT SHALL BE INCLUDED IN THE BID. ADDITIONAL COSTS FOR DEMOLITION OF ITEMS HIDDEN OR INACCESSIBLE DURING THE BIDDING PHASE, SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BEGINNING THE WORK. AT ALTERED CONSTRUCTION REPAIR CUT EDGES, REPLACE CONSTRUCTION. AND FIT NEW TO EXISTING CONSTRUCTION TO MATCH EXISTING WORK, MAKE JOINTS OF NEW AND EXISTING PATCHES VERY SMOOTH, EVEN AND PRACTICALLY INVISIBLE. COORDINATE ALL REPLACEMENT AND REPAIR REQUIREMENTS WITH LANDLORD'S CONSTRUCTION CRITERIA AND TENANTS COORDINATOR. SAW-CUT CONCRETE ON GRADE WITH DIAMOND SAW; JACKHAMMERING WILL NOT BE PERMITTED EXCEPT WITH THE EXPRESSED WRITTEN APPROVAL OF THE LANDLORD AND JJ. CUT IN ACCURATELY LOCATED STRAIGHT LINES AND BREAK OUT SECTIONS. FLOOR 4.DOORS AND FRAMES: IF DOORS AND FRAMES ARE TO BE REUSED ON THE WORK, CAREFULLY REMOVE DOOR FROM FRAMES AND REMOVE FRAMES FROM OPENING, TAKING CARE TO AVOID DAMAGE REMOVE HARDWARE, CLEAN REFURBISH, AND STORE FOR REINSTALLATION WHERE INDICATED FOR DOORS AND FRAMES TO BE SALVAGED, CAREFULLY REMOVE FROM OPENING AND DELIVER FOR STORAGE WHERE INDICATED. D. INSTALL ROUGH CARPENTRY WORK TO COMPLY WITH APPLICABLE CODE STANDARDS UNLESS OTHERWISE INDICATED. FOR SHEATHING UNDERLAYMENT AND OTHER PRODUCTS NOT COVERED IN ABOVE STANDARDS, COMPLY WITH RECOMMENDATIONS OR MANUFACTURER OF PRODUCT INVOLVED FOR USE INTENDED. SET CARPENTRY WORK TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB AND TRUE AND CUT TO FIT. C. LUMBER SHALL BE PROTECTED FROM THE ELEMENTS UNTIL SUCH TIME IT IS USED IN CONSTRUCTION. A. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE CONTENT NOT MORE THAN 19%, WITH THE INDICATION OF "S-DRY" ON THE GRADE STAMP. 2.MAY BE CORE DRILLED WHERE APPROPRIATE FOR INSTALLATION OF PIPES AND SIMILAR ITEMS. COORDINATE ALL CORE LOCATIONS AND SLAB MODIFICATIONS WITH LANDLORD'S STRUCTURAL ENGINEER. WHERE EXISTING PIPING AND OTHER SIMILAR ITEMS ARE UNDER EXISTING SLABS, EXERCISE CARE TO PROTECT FROM DAMAGE EXERCISE CARE WHEN CUTTING ADJACENT TO EXISTING WALLS TO AVOID DAMAGE TO WALLS IF DAMAGED, REPAIR AS REQUIRED TO ORIGINAL CONDITION. DO NOT CUT SUSPENDED SLAB EXCEPT AS NOTED ON DRAWINGS. CEILING PANELS - 2' x 2' USG OYMPIA MICRO CLIMA PLUS #4210 CEILING TILE(DINING) E. MINIMUM 14. GA. FOR WATER HEATER PLATFORM FRAMING. C. ONE BOX OF EACH CEILING TILE FREE OF DAMAGED. Reviewed by SAFEbuilt 12/12/2019 NOTE: ALUMINUM 2,4,8,9 D O O R S C H E D U L E D O O R H A R D W A R ED O O R N O T E S ALUMINUMALUM./GLASS HOLLOW METAL FACTORY FINISH FACTORY FINISH 1 2 01 023'-0" x 7'-0" x 1-3/4" EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE W/O THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. PT-2 DOOR TYPES FRAME TYPES HANDICAP TOILET RM SIGNAGE SEE DETAIL 1/A5 FOR SIGNAGE NOTES SEE SCHEDULE A1 S E E S C H E D U L E SEE SCHEDULE S E E S C H E D U L E 3 SEE SCHEDULE S E E S C H E D U L E 5. EXTERIOR SIDE OF DOOR TO BE PAINTED TO MATCH EXISTING ADJACENT SURFACE. 6. PAINT DOOR AND FRAME PT-3 (WHITE DOVE) WHEN IN BACK OF HOUSE & PT-2 (AMHERST GREY) WHEN IN DINING 7. PROVIDE H.C. ACCESSIBLE MEN'S/WOMEN'S SIGNAGE AT WALL OUTSIDE OF DOOR AS REQUIRED BY GOVERNING AUTHORITIES. 8. RE-KEY EXISTING DOOR PER OWNER'S REQUIREMENTS. 9. REFURBISH WEATHERSTRIPPING, DOOR BOTTOM, ETC. TO LIKE NEW CONDITION 2 T 5' - 0 " ST E N C I L SEE SCHEDULE SE E S C H E D U L E (E)3'-0" x 7'-0"(V.I.F.) REMARKS 1. PROVIDE WOOD BLOCKING FOR DOOR STOPS. 2. CLOSER TO BE MOUNTED ON DOOR, NOT FRAME. CLOSER TYPE TO BE 90° OPENING. 3. PAINT DOORS & FRAMES PT-2. TWO COATS MINIMUM 4. CONTRACTOR TO CONFIRM EXISTING DOOR AND DOOR FRAME ARE IN GREAT CONDITION. REPLACE TO MATCH JIMMY JOHN'S SPECIFICATIONS IF NOT. 1. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. EXCEPTIONS : 1. IN GROUP M OCCUPANCIES, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". THE SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH HIGH ON A CONTRASTING BACKGROUND. WHEN UNLOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. 2. ALL FIRE RATED DOORS AND ALL EXTERIOR SWINGING DOORS SHALL HAVE CLOSURES. 3. ALL INTERIOR DOORS TO BE SOLID WOOD CORE, WITH BIRCH VENEER - PAINTED. 4. ALL NEW/REPLACED DOOR HARDWARE SHALL BE BRUSHED ALUMINUM/SATIN CHROME (US 26D FINISH). 5. ENTRY/EXIT DOORS TO HAVE SIGN - " THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED " POSTED. 6. DOOR OPENING FORCE SHALL NOT EXCEED 5 LBS. 7. ALL DOOR OPERATING HARDWARE SHALL BE MOUNTED AT 38" A.F.F. 8. DOOR HARDWARE MUST BE OPERABLE BY A SINGLE HAND WITHOUT TIGHT GRASPING, TIGHT PINCHING OR TWISTING. 9. "T" INDICATES TEMPERED GLASS. 10. HOLLOW METAL FRAMES MUST BE 2" WELDED FRAMES. 11. ALL INTERIOR DOOR CLOSURES MUST NOT BE SEEN FROM DINING SIDE 12. SILENCERS REQUIRED FOR ALL DOORS 2/A-1 1/A-1 1,2,3,7 HOLLOW METAL FACTORY FINISH1 023'-0" x 7'-0" x 1-3/4"PT-2 2/A-1 1/A-1 1,2,3,7HOLLOW METAL HOLLOW METAL PAINTED PAINTED (1 1/2) PAIR HAGER HINGES BB1279, 4 1/2 x 4 1/2 (US26D FIN.) (1) LCN SUPER SMOOTHEE DOOR CLOSER SERIES #4041 (HINGE SIDE MOUNT) (US26D FIN.) (1) IVES DOOR STOP #60 (CAST ALUM. FIN.) ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). (1) AUGUSTA LEVER HANDLE (2) 6"x34"- BALDWIN BRUSHED S/S KICKPLATES (BOTH SIDES) HARDWARE SET NO. 4: 3,4 (1 1/2) PAIR HAGER HINGES BB1279, 4 1/2 x 4 1/2 (US26D FIN.) (1) LCN SUPER SMOOTHEE DOOR CLOSER SERIES #4041 (US26D FIN.) (1) LOCKSET- SINGLE CYLINDER INTEGRAL DEAD BOLT SECURITY LOCK BY U-CHANGE INDUSTRIES DOOR (1) CLOSER- AUTOMATIC CORBIN-RUSSWIN DC2200 SERIES (US26D) HINGES- TOP, BOTTOM & STANDARD INTERMEDIATE OFFSET PIVOTS (EXISTING) (1) PULL- STYLE G2 BLACK FOR KAWNEER DOORS OR SIMILAR (DOOR 1) ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). (2) 6"x34"- BALDWIN BRUSHED S/S KICKPLATES (BOTH SIDES) HARDWARE SET NO. 1: (CONTRACTOR TO V.I.F.) HARDWARE SET NO. 2: (1) AUGUSTA LEVER HANDLE HARDWARE SET NO. 3: HARDWARE SET NO. 2 (CONT.): (1 1/2) PAIR HAGER HINGES BB1279, 4 1/2 x 4 1/2 (US26D FIN.) (1) LCN SUPER SMOOTHEE DOOR CLOSER SERIES #4041 (US26D FIN.) (1) DELTANA DEL-WBC250US26 2 1/2" WALL BUMPER ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). (1) AUGUSTA LEVER HANDLE (1) 6"x34"- BALDWIN BRUSHED S/S KICKPLATES INTERIOR SIDE ONLY) (1) DELTANA DEL-WBC250US26 2 1/2" WALL BUMPER (1) YALE AU4602LN 626 AUGUSTA LEVER HANDLED PRIVACY LOCK (US26D) (E)3'-0" x 7'-0"(V.I.F.) HOLLOW METAL HOLLOW METAL SUBWAY TILE ON GYP. BOARD OVER METAL STUDS - SEE ELEVATIONS FOR FINISHES FRONT PREP BACK-OF-HOUSE FRP 72" POLISHED S.S. CORNER GUARD FROM TOP OF BASE TO 78" A.F.F. - APPLY CONT. BEAD OF SILICONE - INSTALL AFTER FINAL WALL FINISH #4 X 24" AT 16" O.C. DOWELS (TYP.) LINE OF NEW CONC SLAB TO EXISTING CONC SLAB NEW CONCRETE SLAB TO MATCH EXISTING APPLY A CRACK ISOLATION MEMBRANE PRIOR TO TILE INSTALLATION EXISTING CONCRETE SLAB 2" MET STUD BOXED HEADER, (2) METAL STUDS, W/ (2) RUNNERS (COORD W/ PARTITION TYPE) 1/2" COORD W/ JAMB SEE PARTITION TYPE FOR GYP BD THK, LAYERS & MET. STUD SIZE THK + 1" PARTITION 1/2" 2" SEE PARTITION TYPE FOR GYP BD THK, LAYERS & MET. STUD SIZE DOUBLE MTL STUDS HM DOOR FRAME w/ 3 JAMB ANCHORS PER SIDE 1 15/16" DOOR SIDE FIRE SPRINKLER ROOM A-5 A G 16 A-10 B 13 A-9 A 13 A-9.1 SHT A-10 A 1 TYP. 1 TYP. 1 TYP. 2 2 2 3 3 3 3 3 3 4 5 6 6 78 9 104 WOMEN 10 103 MEN 10 102 BACKROOM 10 10 100 DINING TYP. 10 12 12 14 TYP. 14 TYP. 14 TYP. 14 TYP. 17 17 A-1 3 A-1 3 18 15 A-1.1 8 A-10 C 20 EXISTING WALL: PATCH & REPAIR AS REQUIRED, MAINTAIN ANY EXISTING RATINGS NEW WALL: 6" x 20ga METAL STUDS AT 16" O.C. WITH 5 8" GWB ON EACH EXPOSED SIDE(S) BULKHEAD: BOTTOM OF SOFFIT AT 7'-6" A.F.F. ABOVE COUNTER UNLESS OTHERWISE NOTED (U.N.O.) WALL: 3 5 8" x 20ga METAL STUD AT 16" O.C. WITH 5 8" GWB ON EXPOSED SIDE(S) FINISH EDGE OF WAL MOP SINK HALF WALL: 3 5 8" x 14ga METAL STUDS AT 12" O.C. WITH 5 8" GWB ON EACH SIDE - SEE INTERIOR ELEVS FOR HEIGHT GENERAL NOTES: 1. MINIMUM 20ga METAL STUDS REQUIRED (MUST PROVIDE DIAGONAL CROSS BRACING FOR WALLS OVER 16'-0" AT 4'-0" O.C. SECURED TO STRUCTURE ABOVE ON DROP CEILING SIDE). 2. ALL FRAMING TO CONTINUE TO BOTTOM OF ROOF / DECK. MUST BE BRACED TO THE STRUCTURE ABOVE AS REQUIRED BY CODE. 3. USE MOLD RESISTANT GYP BOARD FOR ALL RESTROOM, KITCHEN / BACK-OF-HOUSE, & MOP SINK WALLS. 4. REFER TO SHEET A-3 FOR SCHEDULED FINISHES: 3 16" SUBWAY TILE AND 12" COVE BASE. 5. ALL FRAMING AND GYP BOARD MUST EXTEND TO ROOF / DECK ON EXTERIOR & DEMISING WALLS. 19 15 17 17 18 15 ARCHITECTURAL FLOOR PLAN 1/4" = 1'-0"A F L O O R P L A N NORTH K E Y E D N O T E S S.S. CORNER DTL 3" = 1'-0"3 1 2 3 4 5 6 7 8 9 10 11 12 JOINT DETAIL 1' = 1'-0"4 13 14 EXISTING SHELL BUILDING. EXISTING STOREFRONT WINDOWS & DOORS. EXISTING 5/8" GYP. BD. ON WALL - CONTRACTOR TO PATCH/REPAIR/ EXTEND TO DECK. TAPED AND SAND SMOOTH READY FOR FINISH. SKIM COAT AS NEEDED TO RECEIVE NEW FINISH. APPLY NEW 5/8" GYP. BD. ON STUDS IF NOT EXISTING. CONTRACTOR TO FIELD VERIFY WALL CAN ACCOMMODATE PROPOSED PLUMBING/ELECTRICAL/FRAMED HALF-WALL AS APPLIES. LINE OF SOFFIT ABOVE. ELECTRICAL PANEL(S) - FULLY RECESSED- PANEL DOORS TO BE FLUSH MOUNTED TO FINISHED SURFACE. WALK-IN COOLER/FREEZER. MOP SINK - SEE 5/A-1.1 AND PLUMBING. PLATFORM MOUNTED WATER HEATER - SEE 5/P-2. MANAGER DESK - SEE 4/A-1.1. CLEAN/SCRAPE/INFILL EXISTING CONCRETE SLAB AND PREP AS REQUIRED FOR NEW FINISHES. NOT USED. ALIGN FACE OF SOFFIT AND FACE OF FULL HEIGHT PARTITION. FRAMING OF SOFFIT WALL MUST ALIGN VERTICALLY WITH FRAMING OF CASH COUNTER & KNEEWALL BELOW - SEE A-1.1. FINISH THIS SIDE BY OTHERS CONTRACTOR TO COORDINATE ALL REMOVAL AND PATCH BACK OF ASPHALT AND CONCRETE AS REQUIRED FOR INSTALLATION OF DRIVE THRU ORDER BOX/MENU BOARD/MAGNETIC LOOP - COORDINATE WITH EXISTING FIELD CONDITIONS. NEW DRIVE THRU WINDOW - SEE A-11. NEW PIPE BOLLARD - SEE F/A-11 MAGNETIC LOOP FOR DRIVE THRU COMMUNICATION PANEL - SEE A-11. DRIVE THRU MENU BOARD/ORDER BOX - SEE SHEET A-11. PAINT EXTERIOR SIDE PER LANDLORD REQUIREMENTS. JAMB DETAIL 3" = 1'-0"1 HEAD DETAIL 3" = 1'-0"2 G E N E R A L N O T E S 1. CONTRACTOR TO PROVIDE CIRCUITS FOR STOREFRONT SIGNS - COORDINATE WITH SIGNAGE SHOP DRAWINGS. 2. ALL MODULAR MILLWORK COMPONENTS ARE CONSTRUCTED OFF SITE BY AN APPROVED VENDOR AND ARE INSTALLED BY G.C. SEE MILLWORK SHEETS A-9 & A-10 FOR DETAILS - LOCATE AS INDICATED. 3. SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 4. SPRINKLER DESIGN / F.A. DESIGN SHALL BE REVIEWED AND APPROVED UNDER SEPARATE PERMIT. 5. ALL SIGNAGE SHALL BE REVIEWED AND APPROVED UNDER SEPARATE PERMIT. S Y M B O L S L E G E N D X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X DOORS CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 A-1 AND DETAILS FLOOR PLAN 16 18 19 15 17 SEE SHEET A-12 FOR EXACT LOCATION OF MENU BOARD AND SPEAKER 1 20 1 1 1 1 1 1 2 2 3 3 Reviewed by SAFEbuilt 12/12/2019 6' - 0 " A . F . F . PROVIDE PLATFORM CONSTRUCTION FOR HWH: 14 GA. 3 5/8" METAL STUDS AT 12" O.C. TO 6'-0" A.F.F. & SPAN 14 GA. 6" METAL JOISTS ACROSS WALLS. PROVIDE F.R.P. ON ALL SIDES OF PLATFORM INCLUDING TOP. "LOW BOY" WATER HEATER WEIGHT FULL OF WATER APPROX. 900 POUNDS HOT WATER HEATER PLATFORM ON HALF WALL - PROVIDE F.R.P. UNDERNEATH ON 3/4" PLYWOOD SCREWED TO 6" METAL JOISTS AT 10" O.C. BOLT REAR ANGLES TO WALL MOP HOOKS HALF WALL BEYOND FAUCET MOP SINK EXISTING FLOOR SLAB EXPANSION TANK PROVIDE SOLID 2x FIRE RATED WOOD BLOCKING IN STUD CAVITY FOR ALL WALL MOUNTED SHELVING (NO SHELVING WHEN SOFFIT IS ABOVE) PROVIDE 5/8" PLYWOOD OVER STUDS FOR P.O.S. BRACKETS PROVIDE SOLID 2x FIRE RATED WOOD BLOCKING AT SHELF BRACKETS IN STUD CAVITY - SEE SHEET A4 FOR LOCATIONS B.O. CEILING 2' - 9 1 / 2 " 1' - 5 1 / 2 " 1' - 7 1 / 2 " 2' - 4 " 8' - 2 1 / 2 " 3' - 5 1 / 2 " TO P O F S H E L F 1 1 / 4 " 1' - 1 1 / 4 " 2' - 4 1 / 4 " 5' - 1 0 " 2' - 0 " 8" 1' - 0 " V.I.F. 2' - 1 1 " PROVIDE 5 8" PLYWOOD BLOCKING BEHIND MANAGER'S DESK FIRE SPRINKLER ROOM 4' - 6 " R. O . 24 ' - 3 3 / 4 " 9' - 1 1 1 / 4 " KN E E W A L L - S E E S H E E T A - 9 . 1 ±5 ' - 9 1 / 4 " 7' - 1 0 1 / 2 " 5' - 6 1 / 2 " 6' - 5 " ALIGN ℄ ALIGN 12 ' - 7 " 9'-7 1/4" 1'-0"3'-4" AL I G N 7' - 8 " 8' - 1 0 3 / 4 " 7' - 1 1 1 / 2 " 5' - 7 1 / 4 " 9' - 4 1 / 4 " 5/ 8 " 3 5 / 8 " 9'-4 1/4" 6" 6'-4 1/2" 7'-10 1/4" 3'-3 3/4"CLEAR 8' - 0 3 / 4 " SEE DET. 5/A-1.12'-1 3/4" 2' - 5 " 22 ' - 7 1 / 2 " ±4'-11 1/2" A1.1 1-A A1.1 1 2'-5 3/4" 2'-5 3/4" 2' - 5 3 / 4 " A1.1 1-A 8'-10 3/4"2'-10" V.I.F. 11'-8 3/4" V.I.F. 11'-8 3/4" V.I.F. 6'-4 3/4" 5 1/4" 3'-4" SEE DET.8/A-1.1 FOR COMMUNITY BOARD 3" CAVITY MIN. FOR CONDENSATE LINES 104 WOMEN 103 MEN 102 BACKROOM 101 PREP 100 DINING ℄ 3' - 2 1 / 2 " 6'-0 3/4" 12'-5" 3 4" PLYWOOD BLOCKING (WITHIN STUDS) BOT. OF SOFFIT 3' - 0 " B.O. CEILING PROVIDE 5/8" PLYWOOD BLOCKING ON STUDS SHELVES PROVIDED BY BEVERAGE COMPANY WATER LINE - SEE P-1 DUPLEX OUTLET SEE E-1 W A L L L E G E N D GENERAL NOTES: 1. MIN 20 ga. METAL STUDS REQUIRED (MUST PROVIDE DIAGONAL CROSS BRACING FOR WALLS OVER 16'-0" @ 4'-0" O.C. SECURED TO STRUCTURE ABOVE ON DROP CEILING SIDE) 2. ALL FRAMING TO CONTINUE TO BOTTOM OF ROOF/DECK. MUST BE BRACED TO THE STRUCTURE ABOVE AS REQUIRED BY CODE. 3. USE MOLD RESISTANT GYP. BOARD FOR ALL RESTROOM, KITCHEN/BOH, & MOP SINK WALLS. 4. REFER TO SHEET A-3 FOR SCHEDULED FINISHES: 3 8" PORCELAIN TILE OR 3 16" SUBWAY TILE AND 1 2" COVE BASE OR 1 4" BRICK VENEER OR 1 2" COVE BASE 5. ALL FRAMING AND GYP. BOARD MUST EXTEND TO ROOF/DECK ON EXTERIOR & DEMISING WALLS. EXISTING WALL. PATCH & REPAIR AS REQUIRED. MAINTAIN ANY EXISTING RATINGS. SOFFIT AT 7'-6" A.F.F. ABOVE COUNTER UNLESS OTHERWISE NOTED. WALL 3 5 8" x 20 ga. METAL STUD AT 16" O.C. W/ 5 8" GWB ON EXPOSED SIDE(S). FINISH EDGE OF WALL WALL 6" x 20 ga. METAL STUDS AT 16" O.C. W/ 5/8" GWB ON EACH EXPOSED SIDE(S). MOP SINK HALF WALL: 3 5 8" x 14ga METAL STUDS AT 12" O.C. WITH 5 8" GWB ON EACH SIDE - SEE INTERIOR ELEVS FOR HEIGHT 6" TAPE AND COMPOUND OVER JOINTS AND SCREW HEADS FINISH AS SCHEDULED 2'-7" 5" 1'-3 1/2" DINING PREP TYPE S SELF TAPPING STEEL SCREWS AT 8" O.C. EDGES 3 5/8" 20 GA. CONT. METAL RUNNER PROVIDE KICKERS AS REQUIRED AT 48" O.C. TO STRUCTURE ABOVE 5/8" GYP. BD. (JOINTS ORIENTED VERTICALLY AND STAGGERED FROM OPPOSITE FACE) DOWNLIGHTING (1) 1/2" FLAT WASHERS AND (2) 1/2" NUTS. 4x4 WOOD FRAMING AT SOFFIT DOWNRODS AT 48" O.C. 35 8" 20 GA. METAL STUDS AT 16" O.C. - BETWEEN DOWNROD FRAMING 3/4" PLYWOOD - TOP OF SHELF 5/8" GYP. BD. (JOINTS ORIENTED VERTICALLY AND STAGGERED FROM OPPOSITE FACE). A.C.T. CEILING PROVIDE 12" I.D. PVC PIPE (WHITE) AT THREADED ROD (TYP.) 3 5/8" METAL STUDS AT 16" O.C. 1/2"Ø ALL THREADED ROD AT 48" O.C. MAX. 1-1/2" x 2" CONT. STAINLESS STEEL ANGLE CORNER GUARD BY K.E.C. ELEV. 7'-6" METAL STUD TRACKS 5 8" GYP. BD. RODS MUST BE STRIPPED OF PVC LETTERING AND CAULKED. DO NOT PAINT. CEILING ELEV. 10'-0" A.F.F. POWER SHOT TO CONCRETE DECK STRUCTURE, TYP. (2) 1/2" FLAT WASHERS (2) 1/2" NUTS P3008 CHANNEL NUT POWER SHOT TO ROOF STRUCTURE, TYP. EXISTING STEEL/CONCRETE DECK 6" TAPE AND COMPOUND OVER JOINTS AND SCREW HEADS FINISH AS SCHEDULED 2'-7" 5" 1'-3 1/2" DINING PREP TYPE S SELF TAPPING STEEL SCREWS AT 8" O.C. EDGES 3 5/8" 20 GA. CONT. METAL RUNNER PROVIDE KICKERS AS REQUIRED AT 48" O.C. TO STRUCTURE ABOVE DOWNLIGHTING (1) 1/2" FLAT WASHERS AND (2) 1/2" NUTS. 4x4 WOOD FRAMING AT SOFFIT DOWNRODS AT 48" O.C. 35 8" 20 GA. METAL STUDS AT 16" O.C. - BETWEEN DOWNROD FRAMING 3/4" PLYWOOD - TOP OF SHELF 5/8" GYP. BD. (JOINTS ORIENTED VERTICALLY AND STAGGERED FROM OPPOSITE FACE). A.C.T. CEILING PROVIDE 12" I.D. PVC PIPE (WHITE) AT THREADED ROD (TYP.) 3 5/8" METAL STUDS AT 16" O.C. 1/2"Ø ALL THREADED ROD AT 48" O.C. MAX. 1-1/2" x 2" CONT. STAINLESS STEEL ANGLE CORNER GUARD BY K.E.C. ELEV. 7'-6" METAL STUD TRACKS 5 8" GYP. BD. EXISTING STEEL/CONCRETE DECK 3" CEILING ELEV. 10'-0" A.F.F. RODS MUST BE STRIPPED OF PVC LETTERING AND CAULKED. DO NOT PAINT. POWER SHOT TO CONCRETE DECK STRUCTURE, TYP. (2) 1/2" FLAT WASHERS (2) 1/2" NUTS P3008 CHANNEL NUT POWER SHOT TO ROOF STRUCTURE, TYP. MENU BOARD - G.C. TO INSTALL 3 4" PLYWOOD BLOCKING WITHIN STUDS ACROSS ENTIRE ANGLED MENU SECTION - SEE DETAIL 3/A-1.1 7' - 6 " T O T O P O F B O A R D 3 4" PLYWOOD BLOCKING WITHIN STUDS.4' - 0 " 1' - 6 " 1' - 0 " 1' - 0 " A-1.1 AND DETAILS FRAMING PLAN RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 FRAMING PLAN 1/4" = 1'-0"A NORTH FRONT SOFFIT SECTION 3/4" = 1'-0"1 MOP SINK NTS5 DRIVER'S / WALL SHELVING 1/2" = 1'-0"2 METRO DESK ELEVATION 1/2" = 1'-0"4 1. CONTRACTOR TO SITE VERIFY ALL EXISTING CONDITIONS, CLEAR HEIGHTS, REQUIRED DEMOLITION, AND CONCRETE SLAB PRIOR TO BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR FAILURE TO PROPERLY INCLUDE ALL COSTS / PRICING FOR T.I. SCOPE OF WORK. 2. VERIFY LAYOUT OF ALL INTERIOR PARTITIONS PRIOR TO FRAMING. NOTIFY ARCHITECT IMMEDIATELY FOR ALL DISCREPANCIES. 3. SEE DETAIL 5/A-2 FOR CEILING BRACING AT ALL WALL TYPES. 4. SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 5. CONTRACTOR TO SITE VERIFY EXACT FIELD CONDITIONS. PROVIDE DEMISING WALL/FULL HEIGHT GYP. BD. AS REQUIRED TO COMPLETE TENANT IMPROVEMENT SCOPE OF WORK. 6. CONTRACTOR TO INCLUDE/COORDINATE ALL REQUIRED CONCRETE FLOOR CORING IF REQUIRED FOR NEW EQUIPMENT/PLUMBING INSTALLATIONS - ALL NEW CONCRETE SHALL MATCH EXISTING SLAB/FRAMING, SEE 4/A1. 7. DIMENSIONS TO FRAMING - FRAMING PLAN ONLY. 8. REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS G E N E R A L N O T E S SOFFIT MENU ELEVATION N.T.S.3 SIDE SOFFIT SECTION 3/4" = 1'-0"1-A CARBONATOR SHELVING 1/2" = 1'-0"6 NOTE TO GCs: DIMENSIONS TO KNEEWALL ARE TO FRAMING. IF KNEEWALL IS PROVIDED BY MIDWEST CABINETS, ADJUST DIMENSIONS TO LOCATE PER FRAMING DIMENSIONS GIVEN. COMMUNITY BOARD 1/2" = 1'-0"8 1 Reviewed by SAFEbuilt 12/12/2019 FIRE SPRINKLER ROOM 8'- 0 " 3'-9 " TO COUNTER 2'-4" TO CNT'R 8' - 0 " 8' - 0 " 2'-1"8'-0" 2' - 1 1 / 2 " 2' - 1 0 " 1'-9 1/2"4'-0" 2' - 3 1 / 2 " 8' - 0 " 4'-6" 2' - 0 " 4'-1"8'-0" 3' - 9 " TO C O U N T E R 1'-9"4'-0" ±12'-6" AFF B.O. DECK ±11'-8" AFF B.O. DECK 100 DINING 1 101 PREP 10'-0" A.F.F. C-1 10'-0" A.F.F. C-1 102 BACKROOM 104 WOMEN 103 MEN C-1 8'-0" A.F.F. C-1 8'-0" A.F.F. NOTE: ALL MEASUREMENT ARE TAKEN FROM CENTERS OF LIGHT FIXTURES. G.C. TO COORDINATE PENDANT LIGHTS WITH CENTER OF TABLES AND BOOTHS. A-2 1 2 2 B.O. SOFFIT 7'-6" A.F.F.3 EQ 5'- 0 " EQ 2' - 2 " 2' - 4 " 2' - 4 " EQ EQ EQ EQ 4 4 5 5 66 6 ±10'-6" AFF B.O. JOISTS ±11'-2" AFF B.O. JOISTS ±12'-6" AFF B.O. DECK ±11'-2" AFF B.O. JOISTS ±11'-2" AFF B.O. BEAMS C-2 SUSPENDED ACOUSTICAL CEILING TILE AT SCHEDULED HEIGHT SCHEDULED HOT WATER HEATER ON RAISED SHELF RAISED SUSPENDED ACOUSTICAL CEILING TILE ABOVE WATER HEATER ACOUSTICAL CEILING TILE SET VERTICALLY AT RAISED CEILING JOISTS B.O. OF CEILING EL: AS SCHEDULEDCOOLER AND FREEZER NOTES: NO CEILING TILE ABOVE WALK-IN FREEZER AND COOLER CONFIRM CEILING HEIGHT FOR DIRECT MOUNTED COMPRESSORS TO BE A MINIMUM OF 3'-0" ABOVE WALKINS. (CLEAR SPACE) . CONFIRM CEILING HEIGHT FOR REMOTE MOUNTED COMPRESSORS TO BE A MINIMUM OF 6" ABOVE WALKINS. (CLEAR SPACE). RETURN GRID TO TOP OF BOXES & INSTALL GRID WITH TILES FOR ENCLOSURE PANELS, PROVIDE CLIPS TO HOLD IN PLACE. CAULK BOTTOM EDGE TO FREEZER AT COOLER. INSTALL SUGGESTED MANUFACTURER CLIPS. PROVIDE EGG-CRATE GRILLS OR EQUAL FOR ADEQUATE VENTILATION PER MANUFACTURER SUGGESTED SPECIFICATION. CEILING AS SCHEDULED VERTICAL ATC, PROVIDE HOLD DOWN CLIPS AS REQUIRED COOLER/FREEZER 2 '-0 " 4'-0" 1. METAL SUSPENSION SYSTEM FOR ACOUSTICAL TILE AND LAY-IN PANEL CEILINGS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C635-00 FOR HEAVY DUTY SYSTEMS. 2. INSTALLATION OF METAL CEILING SUSPENSION SYSTEM FOR ACOUSTICAL TILE AND LAY-IN PANELS SHALL CONFORM TO THE REQUIREMENT OF ASTM C636-00. 3. MAIN RUNNERS AT 4'-0" O.C. CROSS RUNNERS AT 2'-0" O.C. 4. VERTICAL HANGERS TO BE MAX. 8" FROM WALLS. NO. 12 ga VERTICAL HANGERS MAIN RUNNER MIN. OF THREE TURNS CROSS RUNNERS 1 1 CONT. 362S162-33 SECURED WITH (2) #10 TEK SCREWS AT EACH STUD MA X . S T U D C L E A R H E I G H T .4 ' - 0 " M A X CONT. 20GA. STUD BRACE AT WALL AND AT 4'-0" O.C. WITH (2) SCREWS EACH CROSSING 362S162-33 MTL. STUD BRACE AT 48" O.C. WITH (2) #10 SCREWS EACH END A-2 5 ONLY APPROVED ABOVE DROP CEILINGS EXISTING STEEL/CONCRETE DECK TO REMAIN 0.145"x1" POWER ACTUATED FASTENER @ 16" O.C. (MAX.) (TYP.) DEFLECTION GAP #8 WAFERHEAD FRAMING SCREWS (TYP.) SLIPTRACK SYSTEMS 5 8" GWB OVER METAL STUDS, REF. TO WALL LEGEND ON FLOOR PLAN NOTE: 1. REF. TO ELEVATIONS FOR WALL FINISHES 2. G.C. TO VERIFY CONSTRUCTION TYPE PRIOR TO START OF NEW WORK. CONTACT ARCHITECT/ENGINEER FOR APPROPRIATE CONSTRUCTION IF EXISTING STRUCTURE DIFFERS FROM THAT SHOWN. 3. REFER TO WALL LEGEND ON FLOOR PLANS FOR INFORMATION ON STUDS AND DRYWALL CONDITIONS. WALL PARALLEL TO DECKWALL PERPENDICULAR / DIAGONAL TO DECK SLIPTRACK SYSTEMSLONG LEG RUNNER 5 8" GWB OVER METAL STUDS, REF. TO WALL LEGEND ON FLOOR PLAN A-2 PLAN AND DETAILS REFLECTED CEILING RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 REFLECTED CEILING PLAN 1/4" = 1'-0"A C E I L I N G P L A N NORTH K E Y E D N O T E S G E N E R A L N O T E S 1. CONTRACTOR TO PROVIDE CIRCUITS FOR STOREFRONT SIGNS - COORDINATE WITH SIGNAGE SHOP DRAWINGS. 2. ALL LIGHTS IN FOOD PREPARATION AREAS, COOLERS, FREEZERS, STORAGE AND BACK ROOMS ARE TO BE SHIELDED. 3. RETURN GRID TO TOP OF BOXES & INSTALL GRID WITH TILES FOR ENCLOSURE PANELS, PROVIDE CLIPS TO HOLD IN PLACE. CAULK BOTTOM EDGE TO FREEZER AND COOLER. INSTALL SUGGESTED MANUFACTURER CLIPS. PROVIDE EGG-CRATE GRILLS OR EQUAL FOR ADEQUATE VENTILATION PER MANUFACTURER SUGGESTED SPECIFICATION. 4. SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 5. DIMENSIONS ARE FROM INTERIOR FACE OF EXISTING FINISHES AT EXISTING WALLS AND FACE OF FINISH MATERIAL AT NEW STUD WALLS. 6. REFERENCE SHEET E-2 FOR REQUIRED LIGHTING FIXTURE SPECS & HEIGHTS. 7. CEILING GRID MUST ATTACH TO WALL TILE AT SPECIFIED HEIGHT PER A-2. 8. SCRIM CEILING (SWA)/EXPOSED INSULATION IS NOT APPROVED S Y M B O L S L E G E N D X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X DOORS CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X EXPOSED TO DECK. ALL EXPOSED STRUCTURE AND OVERHEAD ITEMS TO BE PAINT Pt-2. NO CEILING / TILE ABOVE COOLER / FREEZER- OPEN TO DECK. SUSPENDED CEILING GRID ABOVE SOFFIT - SEE 2/A-2. ALIGN FACE OF SOFFIT AND FACE OF FULL HEIGHT PARTITION. FRAMING OF BULKHEAD WALL MUST ALIGN VERTICALLY WITH FRAMING OF CASH COUNTER & KNEEWALL BELOW - SEE A-1.1. ADD HEADER FROM ABOVE STOREFRONT WINDOW IF BOXES AND CONDUITS CAN'T BE RECESSED IN THE EXISTING WALL. ALL JUNCTION BOXES AND CONDUITS MUST BE WITHIN WALL SO A FLUSH AND SMOOTH DRYWALL FINISH CAN BE ACHIEVED. IF HEADER IS REQUIRED THEN FURR WALL ABOVE EVERY STOREFRONT WINDOW WITH 5/8" GYP. BD. ON 3 5/8" METAL STUDS. BULKHEAD STARTS AT TOP OF WINDOW OPENING. 1 2 3 4 5 6 SUSPENDED CEILING N.T.S.2 CEILING AT TRANSITION 1/4" = 1'-0"1 CEILING ABOVE WATER HEATER 1-1/2" = 1'-0"4 STUD WALL BRACING 1" = 1'-0"3 SLIP TRACK AT DECK 1" = 1'-0"5 Reviewed by SAFEbuilt 12/12/2019 FIRE SPRINKLER ROOM 1 2 3 11 3 11 104 WOMEN 103 MEN 100 DINING7 A-3 D A-3 D A-3 D A-3 D A-3 D A-3 D A-3 DA-3 D A-3 D A-3 D2 A-3 E A-3 E A-3 E A-3 E A-3 A A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G FF-4 FF-3 102 BACKROOM FF-4 FF-3 101 PREP 2 A-7 1 A-7 3 A-7 4 A-7 3 A-6 4 A-6 2 A-6 1 A-6 6 A-6 5 A-6 3 A-8 4 A-8 1 A-8 6 A-7 5 A-7 2 A-8 13 5 A-8 TI L E S T O T H E C E I L I N G I N R E S T R O O M S PORCELAIN TILE - BULLNOSE - INSTALLED ON TOP OF WALL TILE POLISHED SEALED CONCRETE CERAMIC TILE - SEE ELEVATIONS WB-2 SE E E L E V A T I O N S F O R T I L E H E I G H T 5/8" GYP. B.D. (PAINT AS REQUIRED) BULLNOSE TILE AT TOP ROW 5/8" GYP. B.D. CERAMIC COVE BASE (WB-1, PURITAN GRAY) INSTALLED ON TOP OF WALL TILE (INTEGRAL COVE BASE BULLNOSE) 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS. CERAMIC TILE - SEE ELEVATIONS FOR COLORS TI L E T O E X T E N D T O C E I L I N G WB-1 WALL TILE EXTENDS TO CEILING 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS AND RESTROOMS. FRP CERAMIC COVE BASE (WB-1, PURITAN GRAY) (INTEGRAL COVE BASE BULLNOSE) WB-1 POLISHED CONCRETE RESTROOM BASE & WALL TILE E KITCHEN BASE & WALL TILE C 112" = 1'-0" BACKROOM BASE & FRP G 112" = 1'-0" DINING RM WALL TILE D 112" = 1'-0" 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS AND RESTROOMS. WB-2 COVE BASE - ROPPE - #44 FILLET STRIP - COLOR: TOFFEE FF-3 FF-4 FF-3 FF-4 112" = 1'-0" 3 1/2" 4 3 4" 7 3/8" 1 1 / 4 " 1" 3' - 6 " METAL RUNNER CHANNEL ANCHOR TO SLAB 2'-0" O.C. 3 5 8" METAL STUDS METAL RUNNER CHANNEL (TYP. ALL SIDES) SF-1 D D 5/8" GYP. BD. 5/8" GYP. BD. 5/8" GYP. BD. 5/8" GYP. BD. DINING ROOM HALF WALL TILE D1 112" = 1'-0" 35 8" 7 3/8" 1 1 / 4 " 1" 3' - 6 " METAL RUNNER CHANNEL ANCHOR TO SLAB 2'-0" O.C. 3 5 8" METAL STUDS METAL RUNNER CHANNEL SF-1 FRP ON 1/2" PLYWOOD 5/8" DUROCK/ HARDIEBACKER DINING RM / PREP - HALF WALL A 112" = 1'-0" PREP SIDE WT-4 WT-5 DINING SIDE KNEEWALL BRACES FROM "COLUMBIA ARCHITECTURAL PRODUCTS" - INSTALL @ 48" O.C. (MIN.) FF-3 FF-4 KNEEWALL BRACES FROM "COLUMBIA ARCHITECTURAL PRODUCTS" - INSTALL @ 48" O.C. (MIN.) FF-1 FF-1 WB-1 WOOD 2x4 TOP CAP WOOD 2x4 TOP CAP FF-3 FF-3 FF-2 FF-3FF-2 PORCELAIN TILE - BULLNOSE - INSTALLED ON TOP OF WALL TILE POLISHED SEALED CONCRETE CERAMIC TILE - SEE ELEVATIONS WB-2 SE E E L E V A T I O N S F O R T I L E H E I G H T 5/8" GYP. B.D. (PAINT AS REQUIRED) BULLNOSE TILE AT TOP ROW 5/8" GYP. B.D. DINING RM WALL TILE D2 112" = 1'-0" FF-2 BASE TILE CUT TO 1" BEHIND SODA CABINET CERAMIC TILE - SEE ELEVATIONS FOR COLORS - WALL TILE EXTENDS TO CEILING PA I N T LA M I N A T E / GLOSS WHITECERAMIC TILE 3x6 PREP, DINING ROOM - BUTTED TIGHT & GROUTED - CENIT CERAMICAS FL O O R F I N I S H MARK COLORMODEL NO.MATERIAL MANUFACTURER STYLE DESCRIPTION BA S E CE I L I N G FF-3 PL-1 WT-1 PL A S T I C S FRP FIBERGLASS S-100 - S/2/S SMOOTH FINISH WHITE FF-5 WT-7 BRIGHT WHITEWALL GROUT KITCHEN & BATHROOMS - USE WITH WT-1, WT-2, & WT-3UNSANDED GROUT WHITE ICE A P P R O V E D V E N D O R L I S T VENDOR RESPONSIBILITY FLOORING AND WALL TILE THERE WILL BE ABSOLUTELY NO ACCEPTED SUBSTITUTIONS, COLOR MATCHES OR ALTERNATIVES TO THESE PAINT AND FINISH MATERIAL SPECIFICATIONS. ALL PAINT MUST BE PER MANUFACTURER, COLOR, FINISH/SHEEN AS INDICATED IN THESE CONSTRUCTION DOCUMENTS. PLASTIC LAMINATE RED XABIAP-316 CAARBORITE CASHMERE (CA) DINING RM TABLE TOPS MARLITE WT-10 RAVENWALL GROUT EXTERIOR - USE W/ WT-9SANDED GROUT QUARRY TILE 8" X 8" FLOOR TILE WITH 3/16" JOINTS PURITAN GRAY507QUARRY COVE BASE METRO 6" X 8" BULLNOSE INTEGRAL COVE BASE ATWB-1 ALL WALLS & MILLWORK IN PREP - BACKROOM WHITE DOVEREADY MIX PAINT BENJAMIN MOORE EGGSHELL DINING RM WALL PAINT & BULKHEAD - REAR DOOR & FRAME - SATIN (PREP)PT-3 JET BLACKCOUNTER TOP CAESARSTONE 1 1/4" THICK (3cm) SLIGHT EASED EDGESF-1 EQUIPMENT, FURNITURE, PLUMBING FIXTURES, AND LIGHTING FLOORING SURFACES, INC. (NO SUBSTITUTION) CONTACT: GREG BRUNELLE 401 EAST MERCURY CHAMPAIGN, IL 61822 PHONE: 800.682.1990 217.398.1990 FAX: 217.398.9007 E-MAIL: greg@fsi-1.com CAMPBELLSVILLE INDUSTRIES, INC. CONTACT: DAVID ENGLAND 440 TAYLOR BLVD. CAMPBELLSVILLE, KY 42718 PHONE: 270.465.8135 FAX: 270.465.6839 E-MAIL: steeple@cvilleindustries.com EXTERIOR COLUMNS / RAILINGS TRICORN BLACKSW6258SHERWIN WILLIAMS SEMI-GLOSS PT-7 SAFETY RED-PITTSBURGH SEMI-GLOSS EXTERIOR - BOLLARDS & D-T CURB PT-8 REALIST BEIGESW6078SHERWIN WILLIAMS SEMI-GLOSS EXTERIOR - CORNICE E.I.F.S. PT-9 WT-9 BENGALA NEGROPORCELAIN TILE EXTERIOR - UNDER WINDOWS & AREA SURROUNDING D-T WINDOWROCA12x24 BRICK E.I.F.S. BR-1 EIFS-1 BRICK EXTERIOR INSULATION BELDEN BRICK JUMBO ROSEWOOD - BLENDA-06-14 MORTAR TO BE STANDARD GREY FINISHING SYSTEM (E.I.F.S)- - FINE FINISH - EXTERIOR CORNICE PT-2 EGGSHELL AMHERST GRAYHC-167 DINING RM CEILINGS - OVERHEAD ITEMS - - - 3100 SEE DESCR.FF-1 CONSOLIDECK SEE DESCR. CLEAR PURITAN GRAYQUARRY WB-2 PORCELAIN TILE 6 x 36 JJ BARNWOOD BULLNOSEFLOORING SURFACES - - METRO 507 KEC DESIGN (NO SUBSTITUTION) 301 MERCURY DR. SUITE 1 CHAMPAIGN, IL 61822 PHONE: 217.356.1640 FAX: 217.356.1661 E-MAIL: projects@kecdesign.com WA L L T I L E PAINT PAINT PAINT PAINT PAINT 3/16" GROUT JOINTS - PREP FLOOR/BASE - DINING FLOOR WHEN USING FF-5 GRIND/SCRAPE FLOOR CLEAN. APPLY CONSOLIDECK LS DENSIFIER. REINFORCED PLASTIC 3/16" GROUT JOINTS THROUGHOUT DINING AND RESTROOMS C-1 VENDOR RESPONSIBILITY BENJAMIN MOORE CEILING TILE --PREP - 2'x4' GYPSUM BOARD, 1/2" THICK - WHITE - VINYL SURFACE- GLOSS REDCERAMIC TILE 3x6 PREP - BUTTED TIGHT & GROUTEDCENIT CERAMICASWT-2 RED POPPY GLOSS BLACKCERAMIC TILE 3x6 DINING ROOM - BUTTED TIGHT & GROUTEDCENIT CERAMICASWT-3 BLACK BRIGHT RESTROOM DOORS & FRAMES - REAR DOOR & FRAME (WHEN IN DINING) BACK-OF-HOUSE WALLS - PREP SIDE OF MILLWORK WHEN SITE BUILT CONCRETE WALL GROUT FF-4 BOSTIK SANDED GROUT TIMBER 1/8" GROUT JOINTS - HALF WALL- DINING SIDE FLOORING SURFACES 6 x 36 JJ BARNWOODPORCELAIN TILE 1/8" GROUT JOINTS HALF WALL DINING SIDE - 1/3 BOND JOINT PATTERN EXTERIOR - CORNICE E.I.F.S. - WT-4 WT-5 FF-2 METROPOLITANPANARIA CERAMICA 23 3/4 x 23 3/4 INFUSED FLOOR GROUT PORCELAIN TILE DINING & RESTROOMS WHEN CONCRETE SLAB IS NOT USABLE 3/16" JOINTS BOSTIK SANDED GROUT FRENCH GRAY - 3/16" GROUT JOINTS - DINING & RR WALL BASE TILE WB-3 PORCELAIN TILE FLOORING SURFACES JJ BARNWOOD BULLNOSE 3/16" GROUT JOINTS THROUGHOUT RESTROOMS WHEN FF-5 IS USED - SP E C I A L FI N I S H - 6 x 12 COVED BASE- WT-6 GLOSS WHITECERAMIC TILE 6x6CENIT CERAMICAS JJ WHITE RESTROOM - BUTTED TIGHT & GROUTED POLISH CONCRETE TO 800 GRIT LEVEL. APPLY 2 COATS CONSOLIDECK POLISHGUARD. FINAL POLISH W/ 800 GRIT. FILL ALL EXPANSION JOINTS FLOOR GROUT BOSTIK SANDED GROUT TIMBER BOSTIK BOSTIK COUNTERS / MILLWORK MIDWEST CABINET CO., INC. (NO SUBSTITUTION) CONTACT: CHAD GRIFFIN 1674 INDUSTRIAL AVENUE OTTAWA, KS 66067 PHONE: 785.242.8181 EXT. 18 FAX: 785.242.8183 TRICORN BLACKSW6258SHERWIN WILLIAMS FLAT PT-6 PAINT BEHIND MENU BOARD REGAL SELECT REGAL SELECT WT-6A WT-8A WT-8 6x6CUSTOM MEN'S RESTROOM - BUTTED TIGHT & GROUTED - CUSTOM PRINTCERAMIC TILE CENIT CERAMICAS CENIT CERAMICAS CENIT CERAMICAS CERAMIC TILE CERAMIC TILE JJ WHITE JJ RED 3x6 3x6 RESTROOM - BUTTED TIGHT & GROUTED RESTROOM - BUTTED TIGHT & GROUTED GLOSS WHITE GLOSS RED GLOSS WHITE WITH POLYUREA, SEMI-RIGID JOINT FILLING COMPOUND. FOLLOW ALL MFR. QUIDELINES C-2 EXPOSED DINING ROOM PT-2AMHERST GRAYBENJAMIN MOORE EGGSHELLHC-167REGAL SELECT A-3 PLAN AND SCHEDULE FLOOR FINISH RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 FLOOR FINISH PLAN 1/4" = 1'-0"1 NORTH K E Y E D N O T E S S Y M B O L S L E G E N D X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X DOORS CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X G E N E R A L N O T E S 1. ALL FLOORING FINISH MATERIAL SHALL BE INSTALLED AFTER MILLWORK INSTALLATION. 2. COORDINATE WITH PLUMBING DRAWINGS FOR ALL FLOOR DRAINS AND CLEAN OUT LOCATIONS. 3. ALL FLOOR JOINTS AND QUARRY TILE JOINTS SHALL BE 3/16". 4. ALL CABINETS (EXCEPT STAINLESS STEEL SODA CABINET) MUST BE INSTALLED ON SUBSURFACE PRIOR TO TILE. 5. REFERENCE THE INSTRUCTION GIVEN IN THE BUILD-OUT MANUAL WHEN LAYING OUT WALL AND FLOOR TILE. 6. WHEN FLOOR TILE MUST BE INSTALLED ON WOOD SUBSTRATE, INSTALL 1 2" DUROCK, IF NOT PRESENT. IF EXISTING ENSURE IN LIKE NEW CONDITION OTHERWISE REPLACE APPLICABLE SHEETS. 1 2 3 4 5 6 7 START BULLNOSE QUARRY BASE TILE ON BOTH SIDES OF PREP OPENING. CUT FIRST ROW OF QUARRY FLOOR TILE TO WIDTH OF BULLNOSE BASE TILE. NO FLOOR TILE UNDER MOP SINK. PROVIDE (2) COATS UNDER MOP SINK. SEALED CONCRETE UNDER COOLER/ FREEZER. PROVIDE (2) COATS SEALER. OUTLINE OF MILLWORK. (NO FLOOR TILE). NOT USED. GRIND/SCRAPE FLOOR CLEAN. APPLY CONSOLIDECK LS DENSIFIER. POLISH CONCRETE TO 800 GRIT LEVEL. APPLY 2 COATS CONSOLIDECK POLISHGUARD. FINAL POLISH W/ 800 LEVEL GRIT. FOLLOW ALL MFR. GUIDELINES. PROVIDE FLOOR TRANSITION - INSTALL SCHLUTER RENO-RAMP - ALIGN LOW END OF RAMP TO BE FLUSH WITH CABINET -FLOAT AS REQUIRED. CUT WALL BASE TILE (BEHIND SODA CAB'T ONLY) TO 1" TALL TO ALLOW SODA CAB'T TO SIT FLUSH AGAINST WALL TILE. OUTLINE OF THE SODA CABINET. DO NOT INSTALL BASE TILE ON SODA CABINET. PROVIDE FLUSH TRANSITION - FLOAT AS REQUIRED . EXTEND SUBWAY TILE TO 7'-6" BEHIND SODA CABINET- SEE ELEVATIONS FOR FULL EXTENT. NOT USED. SEE SHEET A-10 FOR CORE DRILL LOCATIONS. SUBWAY TILE ABOVE COUNTER ONLY. TILE (WT-4) ON END OF MILLWORK TO BE INSTALLED AFTER CASH COUNTER (ABOVE) AND/OR SODA CAB'T (ABOVE AND BELOW, IF APPLICABLE. INSTALL SHLUTER SHIENE AT VERTICAL TILE TRANSITION KNEEWAL AND FULL HEIGHT WALL. 8 9 10 11 12 13 14 15 16 1 1 Reviewed by SAFEbuilt 12/12/2019 F I X T U R E A N D E Q U I P M E N T S C H E D U L E JJ E Q U I P . N O QU A N T I T Y EQUIPMENT NAME MANUFACTURER FIXTURE & EQUIPMENT PLAN NOTES: FR A N C H I S E E CO N T R A C T O R LA N D L O R D EL E C T . R E Q . PL U M B . R E Q . ME C H . R E Q . 1 READY ACCESS 131 DRIVE-UP WINDOW W/ AUTO. ELEC. LIGHT BEAM READY ACCESS SEE DETAIL E/A-11 ● ● ● ● 4 AVAYA 2554 FEATURE PHONE AVAYA REFER TO ELECTRICAL DRAWINGS ● ● 1 DRIVER SHELF MID-WEST PROVIDE SOLID BLOCKING- SEE ELEVATIONS & DETAIL B/A-10 ● ● 7 POS TERMINAL -120V (INSTALL DATA/POWER OUTLETS INSIDE CABINET)● ● ● 2 MOP RACKS KEC -● ● 1 34" HIGH CASH MILLWORK & COUNTER W/ DRAWERS MID-WEST REFER TO CABINET DRAWINGS ● ● 1 42" HIGH HALF WALL MILLWORK MID-WEST / SITE BUILT REFER TO CABINET DRAWINGS ● ● 1 METRO DESK AND SHELVES METRO PROVIDED BY KEC EQUIPMENT - SEE 4/A-1.1 ● ● 1 WATER HEATER - "LOW BOY"A.O. SMITH REFER TO PLUMBING DRAWINGS ● ● ● 1 ICE/BEVERAGE UNIT - COUNTERTOP STYLE -120V - CORD AND PLUG (C&P) (INSTALL OUTLET IN CABINET) REFER TO PLUMBING DRAWINGS ● ● ● 1 FREESTANDING ICE/BEVERAGE UNIT LANCER 2300 120V - (C&P)-(INSTALL OUTLET ON WALL BEHIND ICE MACHINE-12" A.F.F.) COKE TO PROVIDE S/S STAND FOR UNIT ● ● ● 1 RPI AIR MERCHANDISER KEC BELOW FRONT COUNTER - 115V ● ● 1 SNEEZE GUARD CUSTOM 31"-24"-31" CONFIGURATION ● ● 4 CUP DISPENSERS SAN JAMAR -● ● 2 WALL MOUNTED CUP DISPENSERS SAN JAMAR -● ● 2 SIDE LOADING BREAD RACK KEC -● 2 91" REFRIG. PREP TABLE AND 12"x 91" S.S. OVERSHELF KAIRAK 120V-1/2 HP ● ● 2 STAINLESS 24"x30" S.S. TABLE ELKAY -● 1 STAINLESS 48"x24" S.S. TABLE ELKAY -● 1 STAINLESS 60"X30" SLICER TABLE ELKAY -● 1 4 DECK OVEN/PROOFER COMBINATION PIPER PRODUCTS 208V - 3 PH - WIRE TO DISCONNECT ● ● ● 1 BAG-N-BOX CARBONATE STOR.- -● 1 BULK C02 SYSTEM - -● ● 1 SURFACE MOUNT FILL BOX PART # 9722279 STAINLESS STEEL BOX CONSTRUCTION - BRASS FILL FITTING. VERIFY EXACT LOCATION IN FIELD ● ● 2 CARBONATOR COKE SEE DETAILS ON A-1.1 AND P-1 ● ● ● ● 1 ICE MAKER (WATER-COOLED) & ICE STORAGE BIN HOSHIZAKI SEE E-SHEETS FOR POWER REQ'TS 1/2" C.W. - 3/8" COND. DRAIN - 1" BIN DRAIN ● ● ● ● 1 DELFIELD SS SODA CABINET - 71" IN LENGTH (UNFINISHED BACK)DELFIELD 1475723 3/8" COND. DRAIN - 1" BIN DRAIN ● ● ● ● 2 STAINLESS HAND SINK w/ FAUCET UNIVERSAL 1/2" C.W.● ● ● 1 Z1996-24 MOP SINK w/ ZURN Z1996-SF FAUCET ZURN REFER TO PLUMBING DRAWINGS ● ● ● 2 MOP HEAD HOOKS KEC INSTALL BENEATH THE WH SHELF, ABOVE FAUCET - SEE 5/A-1.1 ● ● 1 "L" STAINLESS 3 COMPARTMENT SINK ELKAY 1/2" C.W. - 1/2" H.W. - (3) 1 1/2" DRAIN- (2) 24" WIDE DRAIN BOARDS ● ● ● 1 STAINLESS VEGETABLE PREP SINK WITH SPLASH GUARD ELKAY 1/2" C.W. - 1/2" H.W. - (3) 1 1/2" DRAIN- (1) 18" WIDE DRAIN BOARDS ● ● ● 1 SINK FAUCET (ZURN Z842H1.0002 w/OVERHEAD SPRAYER)ZURN REFER TO PLUMBING DRAWINGS ● ● ● 2 SINK FAUCET (Z842H1-15F)ZURN REFER TO PLUMBING DRAWINGS ● ● ● 1 1 DOOR REACH - IN REFRIGERATOR W/ 10 PANS HOSHIZAKI 115V (RECEPT. @ 72" A.F.F.)● ● 1 5' x 6' x 7'-6" TALL WALK-IN FREEZER W/ ELECTRIC DOOR KOLPAK 208/220V/1PH HP-WIRE TO J-BOX 120V-1P - WIRE TO J-BOX ● ● ● 1 8' x 6' x 7'-6" TALL WALK-IN COOLER W/ ELECTRIC DOOR KOLPAK 208/220V/1PH HP-WIRE TO J-BOX 120V-1P - WIRE TO J-BOX ● ● ● 3 DUNNAGE RACKS FOR FREEZER METRO -● 2 METRO SEAL RACKS FOR COOLER METRO -● 3 14"x42" WIRE SHELVING UNITS QUANTUM -● 1 18"x48" WIRE SHELVING UNITS QUANTUM -● 1 18"x60" WIRE SHELVING UNITS QUANTUM -● 2 DISPLAY WALL SHELVES (14"x42")METRO PROVIDE BLOCKING TO SECURE SHELVING UNITS - SEE DETAIL 2/A-1.1 FOR MOUNTING HEIGHTS ● ● 1 DISPLAY WALL SHELVES (14"x48")METRO PROVIDE BLOCKING TO SECURE SHELVING UNITS - SEE DETAIL 2/A-1.1 FOR MOUNTING HEIGHTS ● ● 1 #GSP-HD ELECTRIC SLICER BIZERBA 120V - 1/2 HP - CORD & PLUG ● ● 2 #T1755TBK PAPER TOWEL DISPENSER SAN JAMAR PROVIDE IN WALL BLOCKING ● ● 2 INTERNATIONAL 32 - BK W/ PUSH BUTTON SOAP DISPENSER UPDATE PROVIDE IN WALL BLOCKING ● ● 1 LOW TABLE FOR 4 (42" x 24")KEC -● 1 ADA LOW TABLE FOR 6 (65" x 24")KEC -● 8 BARSTOOLS (MOVABLE)KEC -● 10 ADA ACCESSIBLE CHAIRS KEC -● 1 CUNO #15 WATER FILTER CUNO ENSURE EASY ACCESS TO THIS FILTER CARTRIDGE MOUNT TO WALL- TOP @ 8'-0" A.F.F.- SEE PLUMBING SHEETS ● ● ● 1 SOFFIT MOUNTED MENU BOARD MODAGRAPHICS SOFFIT MOUNTED - CENTEREDA ● ● 1 2'-0" X 8'-0" X 42" H COMMUNITY TABLE KEC REFER TO CABINET DRAWINGS AND SHEET A-10 ● ● 3 STANDING COUNTER POST KEC CORE DRILLED - SEE SHEET A-10 ● ● 1 UNDER COUNTER TRASH RECEPTACLE KEC -● 1 TRASH RECEPTACLE RUBBERMAID S3ET CLASSICS - OPEN TOP - 94L/25G ● 10 STAINLESS STEEL CORNER GUARDS ELKAY ON OUTSIDE CORNERS OF TILE IN PREP AREA ● ● 2 BATHROOM ACCESSORIES - NEW BOBRICK - ZURN REFER TO PLUMBING DRAWINGS AND SHEET A-5 ● ● 6 HCS-2 COAT HOOKS GAMCO -● ● 1 OUTDOOR DRIVE-THROUGH MENU BOARD -120 VAC, 60 HZ, 2 AMPS - VERIFY EXACT LOCATION -SEE D/A11 ● ● ● 1 OUTDOOR DRIVE-THROUGH SPEAKER POST AND MIC - 120 VAC, 60 HZ, 2 AMPS - VERIFY EXACT LOCATION -SEE B/A11 ● ● ● 1 ICED TEA BREWER BUNN-O-MATIC 120V - CORD AND PLUG (C&P)-(INSTALL OUTLET IN CABINET) 1800 WATTS, 15 AMPS, 5-15 RECEPTACLE ● ● ● ● 4 SEAMLESS STAINLESS STEEL ICED TEA DISPENSER BUNN-O-MATIC -● 4 SPEAKER -MUST BE MOUNTED AT +10'-0" AFF. SEE COM-1.● ● 1 VOLUME CONTROL - MUST BE AT MANAGER'S DESK. SEE COM-1.● ● ● 1 RECEIVER - MUST BE AT MANAGER'S DESK. SEE COM-1.● ● ● 1 PICKUP SHELF 34" x 18"KEC ● 1 COMMUNITY INVOLVEMENT WALL KEC SEE ELEVATIONS FOR EXACT PLACEMENT ● 1 24"x24" DUNNAGE RACK FOR CO2 TANK.METRO WITH 6" HIGH LEGS ● 1A 2 2A 3 4 5 5B 6 7 8 8A 9 10 11 11A 12 13 14A 14E 14.2 15A 16 16A 16B 16D 17 18 19 20 20A 21C 21D 21G 21H 22 23 23A 23C 23D 24D 24E 24G 26A 26B 27 28 29 30.2 30.5 32A 33 34 35 37A 38 39 40 41 42 43 44 45 49 50 53 54 55 58 59 60 FIRE SPRINKLER ROOM 16B6 43 6 54 55 24D 24D 24E24G 17 20 20A 7 4 34 16A 16 16D 7 5 23 23C23C 23C 23A 5 23D23D 29 19 28 3 26B 21D 21H 12 12 4 13 26A 26A 104 WOMEN 42 103 MEN 42 50 8 49 5018 21H21G 21C 27 14A 14A 14E 13 3 8A 3 POS TERMINALS AT DRIVER'S SHELF 3 2 2A 41 11 53 9 35 3 11 41 1A 11A 41 29 19 28 3 53 53 53 53 30.2 30.5 37A 38 58 40 32A 32A 3333 3333 102 BACKROOM 101 PREP 100 DINING 41 41 41 41 59 FE 8 FE 8 1 39 2 60 45 44 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 A-4 AND SCHEDULE EQUIPMENT PLAN EQUIPMENT PLAN 1/4" = 1'-0"A NORTH K E Y E D N O T E S G E N E R A L N O T E S 1. PORTABLE FIRE EXTINGUISHERS SHALL BEAR THE LABEL OF AN APPROVED AGENCY, BE AN APPROVED TYPE, AND BE INSTALLED IN A LOCATION VISIBLE AND ACCESSIBLE TO THE OCCUPANTS. FINAL LOCATION BY FIRE PREVENTION BUREAU. PER I.F.C. 906.1 2. PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 LBS. SHALL BE INSTALLED SO THAT ITS TOP IS NOT MORE THAN 5' ABOVE THE FLOOR. PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT EXCEEDING 40 LBS. SHALL BE INSTALLED SO THAT ITS TOP IS NOT MORE THAN 3.5' ABOVE THE FLOOR. THE CLEARANCE BETWEEN THE FLOOR AND THE BOTTOM OF INSTALLED HAND-HELD EXTINGUISHERS SHALL NOT BE LESS THAN 5". 3. PROVIDE MIN. (2) TYPE 2A 10BC FIRE EXTINGUISHERS WITH MAX TRAVEL DISTANCES OF 75' (150' O.C.) MOUNTED BETWEEN 5" AND 5' AND NOT PROTRUDE MORE THAN 4" INTO A CIRCULATION PATH WHEN LEADING EDGE BETWEEN 27" AND 80" A.F.F. HARDWARE TO F.E.C. SHALL BE AT ACCESSIBLE HEIGHTS / LOCATIONS. REFER TO DETAIL 5/A-1 FOR MOUNTING INFORMATION. 4. THE MODULAR MILLWORK COMPONENTS ARE CONSTRUCTED OFF SITE BY AN APPROVED VENDOR AND ARE INSTALLED BY THE G.C. LOCATE MODULAR COMPONENTS AS INDICATED. 5. TOILETS, URINALS, HAND SINKS, 3-COMPARTMENT & PREP SINKS, MOP BASIN AND PERMENANT COUNTERS AND CABINETS MUST BE SEALED TO FLOORS/ WALLS WITH A SILICONE CAULK SEAL. 6. PROVIDE VAPOR PROOF FLUORESCENT LIGHTING IN COOLER & FREEZER MAINTAIN AIR SPACE PER MFR.'S RECOMMENDATION. 7. IF HAND SINKS HAVE SPRING-LOADED FAUCETS, THEY WILL RUN FOR A MINIMUM OF 15 SECONDS 8. GENERAL CONTRACTOR TO ENSURE THAT ALL CO2 LINES ARE CONCEALED WITHIN WALLS. CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING PRIOR TO BID. 9. ALL OUTSIDE TILE CORNERS IN PREP ARE TO HAVE SS CORNER GUARDS INSTALLED. 10.HOT WATER AND DRAIN PIPES EXPOSED UNDER SINK MUST BE INSULATED TO PROTECT AGAINST CONTACT. S Y M B O L S L E G E N D X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X DOORS CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X NOTE: REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS FIRE EXTINGUISHER 1/2" = 1'-0"1 FULLY RECESSED ELECTRICAL PANELS. A.D.A. ACCESSIBLE SEATING. HAND SINK WITH SOAP AND PAPER TOWEL DISPENSER WITH 6" S/S SPLASHGUARDS EACH SIDE. CONTRACTOR TO PROVIDE S/S CLOSURE PIECES TO SEAL AIR SPACE BETWEEN WALL AND COOLER/FREEZER. PROVIDE CONTINUOUS CLEAR SEALANT. WALK-IN COOLER/FREEZER NOTES: - ALL WALK-IN DOORS WILL HAVE INTERIOR/EXTERIOR 36" HIGH DIAMOND TREAD KICK PLATES. - ALL WALK-INS WITH FLOORS WILL HAVE INTERIOR DOOR RAMPS AT ANY DOORS (OTHER THAN THE FREEZER DOOR IN A SHOTGUN APPLICATION). - THE STAINLESS STEEL FINISH OPTIONAL TO BE DETERMINED BY FRANCHISEE. - ALL LIGHT FIXTURES WILL BE L.E.D. WHEN A SEPARATE CEILING MOUNTED FIXTURE IS REQUIRED, IT TOO WILL BE L.E.D. CO2 FILL STATION ON THE EXTERIOR OF THE BUILDING FOR THE BULK CO2 TANK. PROVIDE EXTERIOR FILL BOX CONNECTION. VERIFY/COORDINATE EXACT LOCATION WITH JIMMY JOHN'S PRIOR TO INSTALLATION. HANG LADDER - VERIFY WITH FRANCHISEE. FIRE EXTINGUISHER SEE 1/A-4. NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. 2 NOTE: 1. HEAVY FLOOR MOUNTED EQUIPMENT SUCH AS REFRIGERATED MAKE TABLE COOLERS, REACH-IN COOLERS AND FREEZERS, AND EQUIPMENT STANDS/TABLES, MUST BE MOUNTED ON CASTERS TO ALLOW FOR MOBILITY AND EASY CLEANING OF THE EQUIPMENT, SURROUNDING SURFACES AND ADJOINING EQUIPMENT. 2. LARGE CO2 TANK AND WATER HEATER MUST BE PROVIDED WITH SIX-INCH LEG KITS TO PERMIT EASY CLEANING. 3. HEAVY COUNTER MOUNTED EQUIPMENT SUCH AS SOFT DRINK CARBONATORS AND ICE BEVERAGE DISPENSERS, MOUNTED ON STANDS, WHICH CANNOT BE EASILY MOVED FOR CLEANING MUST BE INSTALL ON FOUR-INCH SANITARY LOAGS OR NEATLY SEALED TO COUNTERS TO FACILITATE CLEANING. 4. HARD TO CLEAN SPACES OR GAGS AROUND EQUIPMENT, COUNTERS, UTILITIES AND PLUMBING MUST BE ELIMINATED TO PROVIDE FOR EASY CLEANING - ALL EQUIPMENT, CABINETS OR COUNTERS THAT ARE NOT MOUNTED ON CASTER OR ARE NOT EASILY MOVEABLE (CURB MOUNTED OR LEGS) MUST BE: A. NEATLY SEALED TO ADJOINING WALLS, EQUIPMENT, CABINETS, OR COUNTERS B. SPACED IN ACCORDANCE WITH SECTION 4-402.11 OF THE RULES AND REGULATIONS SO THE SURFACES OF THE FLOORS, WALLS AND EXTERIOR SURFACES OF EQUIPMENT AND CABINETS CAN BE EASILY CLEANED, C. NEATLY SEALED TO WALLS, EQUIPMENT, CABINET, OR COUNTERS. 1 1 2 1 2 Reviewed by SAFEbuilt 12/12/2019 NOTES: 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND 2. RAISED CHARACTERS SHALL BE 48" MIN. ABOVE THE FLOOR MEASURED TO THE BASELINE OF THE LOWEST RAISED CHARACTER AND 60" MAXIMUM ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST RAISED CHARACTER. 3. SYMBOLS ARE TO BE DISTINCTLY DIFFERENT FROM THE DOOR IN COLOR AND CONTRAST 4. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN. AND SHALL BE A MIN. OF 5/8" TALL. LETTERS SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE 5. LOCATE RAISED AND BRAILLE CHARACTERS, SIGNS ON THE WALL NEAREST TO THE LATCH SIDE OF THE DOOR CL ADA SIGN ADA ROOM IDENTIFICATION SIGN LATCH SIDE OF DOOR GRADE 2 BRAILLE1/4" THICK SIGNS 2 5 4 3 A-5 1 9 7 6 1 2 8 5 1 5 3 7 6 1 2 9 A-5 2 103 MEN 104 WOMEN 1 58 2 4 3 3 TOILET INTERIOR ELEVATION 6" WT-6 WT-7 8'-0" A.F.F. CEILING HT. TYP. WB-2 FF-2 6X6 WHITE WALL TILE THROUGHOUT THE ENTIRE RR WALLS AND DOWN BEHIND THE BASE TILE, TYPICAL SEE TEMPLATE "E" FOR WALL FINISH 8'-0" A.F.F. CEILING HT. SEE TEMPLATE "E" FOR WALL FINISH 34 " M A X . 15" MIN. 29 " M I N . 27 " C L R . 40 " M A X . TO R E F L E C T I V E SU R F A C E 18" 1'-0" 3'-0" 48 " SI D E A P P R O A C H 9 17 " - 1 9 " SE A T TO P 8'-0" A.F.F. CEILING HT. 3'-6" SEE TEMPLATE "E" FOR WALL FINISH 2' - 9 3 / 4 " 3' - 4 " 18 " 19 " MA X 8 3 3'-6"1'-0" 3'-4" 8'-0" A.F.F. CEILING HT. SEE TEMPLATE "E" FOR WALL FINISH 17 " - 1 9 " SE A T TO P SEE TEMPLATE "E" FOR WALL FINISH 8'-0" A.F.F. CEILING HT. SEE TEMPLATE "E" FOR WALL FINISH 34 " M A X . 15" MIN. 29 " M I N . 27 " C L R . 40 " M A X . TO R E F L E C T I V E SU R F A C E 18" 48 " SI D E A P P R O A C H 9 17 " - 1 9 " SE A T TO P 8'-0" A.F.F. CEILING HT. 4'-0" SEE TEMPLATE "E" FOR WALL FINISH 2' - 9 3 / 4 " 3' - 4 " 18 " 19 " MA X 8 3 3'-6"1'-0" 3'-4" 8'-0" A.F.F. CEILING HT. SEE TEMPLATE "E" FOR WALL FINISH 17 " - 1 9 " SE A T TO P 8'-0" A.F.F. CEILING HT. 8'-0" A.F.F. CEILING HT. 2'-0" 1'-0" 3'-0" 2'-0" A-5 AND ELEVATIONS RESTROOM PLAN RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 K E Y E D N O T E S G E N E R A L N O T E S S Y M B O L S L E G E N D 1 2 3 5'-0" REQUIRED A.D.A. TURNING RADIUS. 30"x48" REQUIRED A.D.A. CLEAR ACCESS. 56"x60" REQUIRED A.D.A. CLEAR ACCESS. X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X DOORS CEILING FINISHES SEE SHEET A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X ENLARGED PLAN 3/8" = 1'-0"A ADA SIGNAGE DETAIL 1/4" = 1'-0"B 1. SEE SHEET A-6 TO A-8 FOR ALL WALL FINISHES. 2. SEE SHEET A-1 FOR WALL LEGEND & NOTES. 3. LAVATORY MIRRORS TO BE MOUNTED SO THAT REFLECTING SURFACE IS 40" MAX. ABOVE THE FLOOR. 4. RESTROOMS SHALL HAVE PERMANENT ROOM IDENTIFICATION ADJACENT TO PULL SIDE OF DOOR 60" A.F.F. TO CENTER OF SIGN. PER A.D.A. REQUIREMENTS. SEE SHEET A-5. 5. PROVIDE FIRE TREATED WOOD BLOCKING AT ALL GRAB BAR AND ACCESSORIES LOCATIONS. 6. WALL TILE TO BE BUTTED TIGHT, THEN GROUTED. 7. REFERENCE THE INSTRUCTIONS GIVEN IN THE JIMMY JOHN'S BUILD OUT MANUAL WHEN LAYING OUT WALL AND FLOOR TILE 8. SILICON THE TOILET TO THE FLOOR. 9. REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS. WOMEN'S TOILET 3/8" = 1'-0"1 MEN'S TOILET 3/8" = 1'-0"2 2740TOILET PAPER DISPENSER BOBRICK COLOR/STYLE T O I L E T A C C E S S O R Y S C H E D U L E MODEL NO.ACCESSORY MANUFACTURER SIZE/REMARKS INTERNATIONAL 32SOAP DISPENSER UPDATE MIRROR AT TOILET LAVATORIES BOBRICK 150 SERIESACCESSIBLE GRAB BARS GAMCO LAVATORY WALL HUNG INSULATION TRUEBRO WHITE WHITEHANDI LAV-GUARD NOTE: ALL TOILET ACCESSORIES SHALL MEET ALL REQUIREMENTS OF THE ANSI 117 ACCESSIBILITY GUIDELINES AND ALL LOCAL CODE REQUIREMENTS. (800) 340-5969 1 1/2"Ø x 42" LONG & 1 1/2"Ø x 36" LONG & LOCATED 35" TO TOP OF GRAB BAR AFF w/ NON-SLIP SURFACE. INSTALL PER PLAN ELEVATIONS. PROVIDE WALL SUPPORT BLOCKING TO ALLOW BARS TO SUPPORT 250 POUNDS OF FORCE APPLIED IN ANY DIRECTION. GRAB BAR MUST BE 1 1/2" CLEAR, FROM FINISHED FLOOR. INSULATE THE P-TRAP AND ANGLE VALVES w/FULLY MOLDED INSULATION KIT PER A.D.A.A.G. REQ'TS 150 SERIESVERTICAL GRAB BAR GAMCO NO SUBSTITUTIONS ON ANY FIXTURES #B-165 1830 18" x 30"- SHIM AS REQUIRED - PROVIDE FULL PERIMETER CAULKING -- --SEE PLUMBING SHEETS 18" VERTICAL - PROVIDE BLOCKING AS REQ'D PROVIDE BLOCKING AS REQ'D WALL MOUNT PROVIDE BLOCKING AS REQ'D BK W/ PUSH BUTTON CHROME TRIM SEAT WHITE WATER CLOSET (TANK TYPE) BOWL, ELONGATED WITH AQUAGUARD TANK LINER Z5955SS (OPEN FRONT CHECK HINGE) SEE PLUMBING SHEETS FOR TOILET INFO SEE PLUMBING SHEETS FOR TOILET INFO SEE PLUMBING SHEETS FOR TOILET INFO SEE PLUMBING SHEETS FOR TOILET INFO PAPER TOWEL DISPENSER T1755TBKSAN JAMAR BK WALL MOUNT PROVIDE BLOCKING AS REQ'D 1 1 Reviewed by SAFEbuilt 12/12/2019 NOTES: 1. DINING ROOM AND KITCHEN WALL TILE TO BE BUTTED TIGHT, THEN GROUTED. 2. REFER TO SHEET A-3 FOR INTERIOR FINISH SCHEDULE. DRYWALL, WALL, FINISHES TO EXTEND TO DECK/CEILING. 3. ALL OUTSIDE CORNERS OF WALL TILE IN CUSTOMER AREA MUST RECEIVE BULLNOSE AND BASE MUST BE A BULLNOSE TILE W/ 45° MITER. 4. MUST FURR OUT AROUND BEAMS AT WALLS TO CREATE A BULKHEAD. DRYWALL MUST EXTEND TO DECK/CEILING. 5. STRUCTURAL MEMBERS INTERSECTING DINING WALLS THAT DO NOT ALLOW DRYWALL/FINISHES TO EXTEND TO DECK MUST BE FURR'D OUT TO ALLOW CONTINUATION OF DRYWALL/FINISHES TO EXTEND TO DECK/CEILING. 6. FULL SHEETS OF FRP ARE TO BE INSTALLED RESULTING IN ONLY VERTICAL SEAMS. HORIZONTAL BREAKS IN FRP ARE NOT APPROVED. GROUT FOR ALL WHITE, RED & BLACK WALL TILE NOTE ON GROUT COLOR: WT-7 WB-2 TYP. FF-2 WT-1 WT-7 PT-3 WB-1 SE E A - 2 SE E A - 2 SE E A - 2 CENTER SOFFIT MENUBOARD WITHIN PAINTED (PT-6) ANGLED BULKHEAD CASH COUNTER WB-1 WT-1 TYP. WT-7 FF-2 WB-2 WB-1 SE E A - 2 FRP - SMOOTH FACE 3/4" PLYWOOD BLOCKING - SEE 3 / A-1.1 (TYP.) PT-3 TYP. BULLNOSE (TYP) WT-7 PT-3 WT-1 WT-1 BULLNOSE TYP. WT-7 WT-1 WT-1 WT-7 BULLNOSE TYP. WT-1 MITER TILE 45° AT ALL OUTSIDE CORNERS (TYP.) WB-2 TYP. FF-2 WT-1 (STACKED BOND TYP.) WT-7 BULLNOSE PT-3 SE E A - 2 5' - 3 " WT-2 WT-7 WT-3 PT-3 FRP WT-4 WT-5 WT-4 WT-5 WT-3 (STACKED BOND TYP.) WT-7 WT-1 WT-3 (STACKED BOND TYP.) BULLNOSE (TYP) EDGE STOREFRONT (TYP. FOR WT-1, WT-2, & WT-3) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) SE E A - 2 PT-2 PAINT LINE TYP. PT-6 FF-3 FF-3 FF-3 **ALL INTERIOR SIGNAGE SHOWN ON ELEVATIONS AND ENTIRE SINTRA SIGN PACKAGE TO BE PROVIDED BY OWNER AND INSTALLED BY G.C. ±11'-8" B.O. DECK ±10'-6" B.O. JOISTS±11'-2" B.O. BEAMS ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS ST O R E F R O N T SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E SEE BACK ROOM ELEVATIONS SEE TEMPLATE "D2" FOR WALL FINISH SS FINISH EXTEND SUBWAY TILE UP TO 7'-6" AFF AS SHOWN PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.) 7' - 6 " 3'-2" CL COMMUNITY WALL 42" X 72" CATERING 26"x36" 7' - 1 0 " CL CL 3'-6" CL 7' - 1 0 " CL EQEQ ±11'-8" B.O. DECK ±10'-6" B.O. JOISTS ±11'-2" B.O. BEAM ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E SEE BACK ROOM ELEVATIONS SEE TEMPLATE "D" FOR WALL FINISH SS FINISH EXTEND SUBWAY TILE UP TO 7'-6" AFF AS SHOWN PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.) ST O R E F R O N T CENTER SOFFIT MENU BOARD PAINT BEHIND MENUBOARD - PT-6 POP 233 4"x 293 4" 3" 3" SEE TEMPLATE "Z" FOR WALL FINISH SEE TEMPLATE "Y" FOR WALL FINISH OBLIQUE VIEW WT-4 WT-5 WT-4 WT-5 WT-4 WT-5 +7'-6" B.O. SOFFIT SEE TEMPLATE "D2" FOR WALL FINISH SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E ±11'-2" B.O. BEAM ST O R E F R O N T ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS CENTER SOFFIT MENU BOARD PAINT BEHIND MENUBOARD - PT-6 POP 233 4"x 293 4" OBLIQUE VIEW SEE TEMPLATE "Z" FOR WALL FINISH SEE TEMPLATE "Y" FOR WALL FINISH EXTEND SUBWAY TILE UP TO 7'-6" AFF AS SHOWN FINISH "D" 3" 3" CL CL "THE ORIGINAL" LOGO - 72"x48" DECAL APPLIED 3 DAYS AFTER FINAL PAINTING (INSTALLED BY GC)EQ 7' - 1 0 " EQ WB-1 WT-4 WT-5 WT-4 WT-5 SS FINISH FINISH "C" +7'-6" B.O. SOFFIT SEE TEMPLATE "D2" FOR WALL FINISH SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.)±12'-6" B.O. DECK ±10-6" B.O. JOISTS BEYOND ±11-8" B.O. DECK BEYOND ±11'-2" B.O. JOISTS ±11'-2" B.O. BEAM ST O R E F R O N T ±11'-2" B.O. BEAM ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS OPEN TO DINING SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E SEE TEMPLATE "D" FOR WALL FINISH SS FINISH EXTEND SUBWAY TILE UP TO 7'-6" AFF AS SHOWN ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS ±11'-2" B.O. BEAM 10 ' - 6 " PA I N T L I N E SEE TEMPLATE "D2" FOR WALL FINISH A-6 ELEVATIONS INTERIOR RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 ELEVATION AT DINING 1/4" = 1'-0"1 ELEVATION AT DINING 1/4" = 1'-0"2 ELEVATION AT DINING 1/4" = 1'-0"4 ELEVATION AT DINING 1/4" = 1'-0"3 ELEVATION AT DINING 1/4" = 1'-0"5 ELEVATION AT DINING 1/4" = 1'-0"6 Reviewed by SAFEbuilt 12/12/2019 NOTES: 1. DINING ROOM AND KITCHEN WALL TILE TO BE BUTTED TIGHT, THEN GROUTED. 2. REFER TO SHEET A-3 FOR INTERIOR FINISH SCHEDULE. DRYWALL, WALL, FINISHES TO EXTEND TO DECK/CEILING. 3. ALL OUTSIDE CORNERS OF WALL TILE IN CUSTOMER AREA MUST RECEIVE BULLNOSE AND BASE MUST BE A BULLNOSE TILE W/ 45° MITER. 4. MUST FURR OUT AROUND BEAMS AT WALLS TO CREATE A BULKHEAD. DRYWALL MUST EXTEND TO DECK/CEILING. 5. STRUCTURAL MEMBERS INTERSECTING DINING WALLS THAT DO NOT ALLOW DRYWALL/FINISHES TO EXTEND TO DECK MUST BE FURR'D OUT TO ALLOW CONTINUATION OF DRYWALL/FINISHES TO EXTEND TO DECK/CEILING. 6. FULL SHEETS OF FRP ARE TO BE INSTALLED RESULTING IN ONLY VERTICAL SEAMS. HORIZONTAL BREAKS IN FRP ARE NOT APPROVED. GROUT FOR ALL WHITE, RED & BLACK WALL TILE NOTE ON GROUT COLOR: WT-7 WB-2 TYP. FF-2 WT-1 WT-7 PT-3 WB-1 SE E A - 2 SE E A - 2 SE E A - 2 CENTER SOFFIT MENUBOARD WITHIN PAINTED (PT-6) ANGLED BULKHEAD CASH COUNTER WB-1 WT-1 TYP. WT-7 FF-2 WB-2 WB-1 SE E A - 2 FRP - SMOOTH FACE 3/4" PLYWOOD BLOCKING - SEE 3 / A-1.1 (TYP.) PT-3 TYP. BULLNOSE (TYP) WT-7 PT-3 WT-1 WT-1 BULLNOSE TYP. WT-7 WT-1 WT-1 WT-7 BULLNOSE TYP. WT-1 MITER TILE 45° AT ALL OUTSIDE CORNERS (TYP.) WB-2 TYP. FF-2 WT-1 (STACKED BOND TYP.) WT-7 BULLNOSE PT-3 SE E A - 2 5' - 3 " WT-2 WT-7 WT-3 PT-3 FRP WT-4 WT-5 WT-4 WT-5 WT-3 (STACKED BOND TYP.) WT-7 WT-1 WT-3 (STACKED BOND TYP.) BULLNOSE (TYP) EDGE STOREFRONT (TYP. FOR WT-1, WT-2, & WT-3) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) SE E A - 2 PT-2 PAINT LINE TYP. PT-6 FF-3 FF-3 FF-3 **ALL INTERIOR SIGNAGE SHOWN ON ELEVATIONS AND ENTIRE SINTRA SIGN PACKAGE TO BE PROVIDED BY OWNER AND INSTALLED BY G.C. ±11'-8" B.O. DECK ±10'-6" B.O. JOISTS B.O. BEAMS ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS ST O R E F R O N T SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.) COMMUNITY WALL 42" X 72" CATERING 26"x36" ±11'-2" WB-1 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "X" FOR WALL FINISH OPEN TO DINING WB-1 WT-4 WT-5 SEE TEMPLATE "C" FOR WALL FINISH SEE TEMPLATE "G" FOR WALL FINISH +7'-6" B.O. SOFFIT ELECTRICAL PANELS BEYOND OBLIQUE VIEW ±11'-8" B.O. DECK ±10'-6" B.O. JOISTS ±11'-2" B.O. BEAM ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.) ST O R E F R O N T SEE TEMPLATE "C" FOR WALL FINISH +7'-6" B.O. SOFFIT 10'-0" ACT CEILING AT PREP & BACK ROOM BLOCKING (TYP.) BLOCKING (TYP.) 3' - 0 " 3' - 0 " ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "C" FOR WALL FINISH BLOCKING (TYP.) SEE TEMPLATE "D" FOR WALL FINISH 10 ' - 6 " PA I N T L I N E PAINT PT-2 ABOVE 10' 6" A.F.F. @ DINING (TYP.) ±11'-2" B.O. BEAM ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS 10'-0" ACT CEILING AT PREP & BACK ROOM +7'-6" B.O. SOFFIT WB-1WB-1WT-4 WT-5 SEE TEMPLATE "X" FOR WALL FINISH OPEN TO PREP ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "G" FOR WALL FINISH FINISH "G" ±12'-6" B.O. DECK ±11'-2" B.O. JOISTS 10'-0" ACT CEILING AT PREP & BACK ROOM BLOCKING (TYP.) SEE TEMPLATE "C" FOR WALL FINISH SEE TEMPLATE "G" FOR WALL FINISH OPEN TO BACK ROOM A-7 ELEVATIONS INTERIOR RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 ELEVATION AT DINING/ PREP 1/4" = 1'-0"1 ELEVATION AT DINING/ PREP 1/4" = 1'-0"3 ELEVATION AT DINING/ PREP 1/4" = 1'-0"2 ELEVATION AT PREP 1/4" = 1'-0"4 ELEVATION AT PREP 1/4" = 1'-0"5 ELEVATION AT PREP 1/4" = 1'-0"6 1 1 Reviewed by SAFEbuilt 12/12/2019 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "G" FOR WALL FINISH 6 COAT HOOKS NOTES: 1. DINING ROOM AND KITCHEN WALL TILE TO BE BUTTED TIGHT, THEN GROUTED. 2. REFER TO SHEET A-3 FOR INTERIOR FINISH SCHEDULE. DRYWALL, WALL, FINISHES TO EXTEND TO DECK/CEILING. 3. ALL OUTSIDE CORNERS OF WALL TILE IN CUSTOMER AREA MUST RECEIVE BULLNOSE AND BASE MUST BE A BULLNOSE TILE W/ 45° MITER. 4. MUST FURR OUT AROUND BEAMS AT WALLS TO CREATE A BULKHEAD. DRYWALL MUST EXTEND TO DECK/CEILING. 5. STRUCTURAL MEMBERS INTERSECTING DINING WALLS THAT DO NOT ALLOW DRYWALL/FINISHES TO EXTEND TO DECK MUST BE FURR'D OUT TO ALLOW CONTINUATION OF DRYWALL/FINISHES TO EXTEND TO DECK/CEILING. 6. FULL SHEETS OF FRP ARE TO BE INSTALLED RESULTING IN ONLY VERTICAL SEAMS. HORIZONTAL BREAKS IN FRP ARE NOT APPROVED. GROUT FOR ALL WHITE, RED & BLACK WALL TILE NOTE ON GROUT COLOR: WT-7 WB-2 TYP. FF-2 WT-1 WT-7 PT-3 WB-1 SE E A - 2 SE E A - 2 SE E A - 2 CENTER SOFFIT MENUBOARD WITHIN PAINTED (PT-6) ANGLED BULKHEAD CASH COUNTER WB-1 WT-1 TYP. WT-7 FF-2 WB-2 WB-1 SE E A - 2 FRP - SMOOTH FACE 3/4" PLYWOOD BLOCKING - SEE 3 / A-1.1 (TYP.) PT-3 TYP. BULLNOSE (TYP) WT-7 PT-3 WT-1 WT-1 BULLNOSE TYP. WT-7 WT-1 WT-1 WT-7 BULLNOSE TYP. WT-1 MITER TILE 45° AT ALL OUTSIDE CORNERS (TYP.) WB-2 TYP. FF-2 WT-1 (STACKED BOND TYP.) WT-7 BULLNOSE PT-3 SE E A - 2 5' - 3 " WT-2 WT-7 WT-3 PT-3 FRP WT-4 WT-5 WT-4 WT-5 WT-3 (STACKED BOND TYP.) WT-7 WT-1 WT-3 (STACKED BOND TYP.) BULLNOSE (TYP) EDGE STOREFRONT (TYP. FOR WT-1, WT-2, & WT-3) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) (1/2 BOND TYP.) SE E A - 2 PT-2 PAINT LINE TYP. PT-6 FF-3 FF-3 FF-3 **ALL INTERIOR SIGNAGE SHOWN ON ELEVATIONS AND ENTIRE SINTRA SIGN PACKAGE TO BE PROVIDED BY OWNER AND INSTALLED BY G.C. 10'-0" ACT CEILING AT PREP & BACK ROOM SEE A-4 T.O. WALK-IN BOX A-2 1 TURN 2'X4' CEILING GRID DOWN TO TOP OF COOLER BELOW - ALIGN WITH FACE OF COOLER, BRACE AS REQUIRED. LAY IN WHITE 2'X4' EGG CRATE PANELS - SECURE WITH HOLD DOWN CLIPS SEE TEMPLATE "G" FOR WALL FINISH SEE TEMPLATE "G" FOR WALL FINISH OPEN TO PREP FINISH "G" LADDER 6' - 0 " 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "G" FOR WALL FINISH LADDER ELECTRICAL PANELS 10'-0" ACT CEILING AT PREP & BACK ROOM SEE TEMPLATE "G" FOR WALL FINISH SEE TEMPLATE "C" FOR WALL FINISH SEE TEMPLATE "G" FOR WALL FINISH FINISH "G" OPEN TO PREP SEE TEMPLATE "G" FOR WALL FINISH 10'-0" ACT CEILING AT PREP & BACK ROOM 8' - 0 " TO P O F F I L T E R 6' - 0 " A-8 ELEVATIONS INTERIOR RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 ELEVATION 4 1/4" = 1'-0" AT BACKROOM ELEVATION 1 1/4" = 1'-0" AT BACKROOM ELEVATION 2 1/4" = 1'-0" AT BACKROOM ELEVATION 5 1/4" = 1'-0" AT BACKROOM ELEVATION 3 1/4" = 1'-0" AT BACKROOM Reviewed by SAFEbuilt 12/12/2019 1" X 1" ALUM ANGLE 26 3/8" 21 3/8" 11 1 / 2 " 5 3/4"5 3/4"5 3/4"5 3/4" 26 3/8" 21 3/8" 11 1 / 2 " 5 3/4"5 3/4"5 3/4"5 3/4" 34 " ADJ. SHELF ADJ. SHELF REMOVEABLE PANEL BASE BY OTHERS PL-3 PL - 3 PL-3 PL - 3 WHITE VENT PL-3 WHITE 3MM ADJ. SHELF ADJ. SHELF REMOVEABLE PANEL BASE BY OTHERS PL-3 PL - 3 PL-3 PL - 3 118 1/8" CAESARSTONE JET BLACK CAESARSTONE JET BLACK 32 3 / 4 " SKEWED 2 9/16" 23" 3 1/2" 24 1/2" 3 1/2" 23" 2 9/16" SKEWED 116" 32 3 / 4 " 118 1/8" 46 15/16"24 1/4" TILE TILE TILE34 " TILE TILE BASE BY OTHERS 46 15/16" CHIP PULLOUT SHELVES TILE CHIP PULLOUT SHELVES 1 8" FLAT ALUMINUM 1 8" FLAT ALUMINUM 5 3/4"5 3/4" BASE BY OTHERS 5 3/4" BASE BY OTHERS 5 3/4" 26 3/8" PL-1 116" 24 1/2"28 7/8" 3 13/16" SKEWEDSKEWED 3 13/16" 28 7/8" 12 " 12" CUTOUT FOR VENT 118 1/8" 33 7/16"33 7/16" 19 1 / 8 " 19 1/8" 24 1/4" 30 1 / 4 " 34 " 32 3 / 4 " 30" 32" 11 1/2" 6 3 / 4 " LOOSE FLOOR CLEAT 1/4" CEMENT BOARD WHITE 3MM WHITE INTERIOR CAESARSTONE JET BLACK TOP BLACK INTERIOR BLACK 3MM 1 8" ALUMINUM TRIM 1 4" BLACK ACRYLIC DIVIDERS KV8900 12" SLIDES 30 1/2" ADJ. SHELVES 9 3 / 8 " 18 " 3 3 / 4 " 29 " 13 1/2" 5 3 / 4 " 2 3/4" 25 3 / 4 " 32" PL-1 3" BLACK GROMMET 1" x 1" ALUMINUM ANGLE ACCESS PANEL 34 " 30 1/2" 9" VENT 6" 2 3/4" SECURE ACCESS PANEL WITH L-BRACKETS PREP SIDE DINING SIDE FRAMING PLAN SECTIONS GROMMET A-9 DETAILS CABINET RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 CUSTOMER ORDER COUNTER 1 1/2" = 1'-0"A NOTE: ALL PLYWOOD AND DUROCK/HARDIEBACKER MUST BE GLUED AND SCREWED TO FRAMING (AT ALL CASH COUNTER AND HALF-WALL FRAMING) Reviewed by SAFEbuilt 12/12/2019 7 3/8" 1 1 / 4 " SF-1 SECTION 6 1 / 4 " 34 1 / 2 " 40 3 / 4 " PREP SIDE METAL RUNNER CHANNEL 42 " DINING SIDE SEE A/A-3 FOR MORE DETAILS A/A-3 12" PLYWOOD WALL TILE ON 5/8" DUROCK/ HARDIEBACKER 35 8" METAL STUDS @ 16" O.C. PROVIDE KNEEWALL BRACES FROM "COLUMBIA ARCHITECTURAL PRODUCTS" - INSTALL @ 48" O.C. (MIN.) 3 5/8" 1"1" A/A-3 5 3/8" WOOD 2x4 TOP CAP COUNTER TOP PLAN 7 3 / 8 " PREP SIDE ELEVATION SNEEZE GUARDS 40 3 / 4 " 42 " 1 1 / 4 " ELECTRICAL BOXES AND CUTOUTS BY EC SF-1 CUSTOMER ORDER COUNTER 16 " 2 3/8" 6 1 / 4 " FRP BASE BY OTHERS SNEEZEGUARD POST PLAN 2 7/8"2"30 1/4"23 1/4"30 1/4" EQ 2" EQ 1"1" 1" 34 1 / 2 " KNEEWALL PLAN 5 3 / 8 " 119 1/4" 119 7/8" 120 3/8" (FRAMING TO FRAMING) (SUBSTRATE TO SUBSTRATE) (TILE TO TILE) FRP INSTALLED ON 1/2" PLYWOOD 3 5/8" METAL STUDS @ 16" O.C. DINING SIDE PREP SIDE PREP SIDE DINING SIDE 2"2"2" DINING SIDE PREP SIDE 119 7/8"(SUBSTRATE TO SUBSTRATE) 121 3/8" 5 3 / 8 " 121 3/8" WT-4 & (WT-5 GROUT) INSTALLED ON 5/8" DUROCK/ HARDIEBACKER VERTICAL GRAIN WT-4 & (WT-5 GROUT) BULLNOSE EACH SIDE - INSTALLED ON DUROCK/ HARDIEBACKER BY G.C. - FROM 34" AFF TO 40 3 /4" AFF) DUROCK/ HARDIEBACKER (FULL HEIGHT) A-9.1 DETAILS CABINET RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 NOTE: TILE ON END OF MILLWORK TO BE INSTALLED AFTER CASH COUNTER (ABOVE) AND/OR SODA CAB'T (ABOVE & BELOW IF APP). NOTE: ALL PLYWOOD AND DUROCK/ HARDIEBACKER MUST BE GLUED AND SCREWED TO FRAMING (AT ALL CASH COUNTER AND HALF-WALL FRAMING) FRONT COUNTER WALL -SECTION 1 1/2" = 1'-0"A FRONT COUNTER WALL 1" = 1'-0"B Reviewed by SAFEbuilt 12/12/2019 1 1 / 4 " 48" 4" 15 1 / 4 " 13" 1 1 / 4 " 41 1 / 2 " SF-1 FRONT ELEVATION B1 SECTION B2 B2 A-10 4" 41 1 / 2 " SF-1 5"5" 24" 10 " 10 " "THE ORIGINAL GRANITE BRACKET" (https://originalgranitebracket.com) - 12"x10"(10" LEG VERTICAL) TABLE / STOOL POST3/16" THICK, 4 1/2" DIA. STEEL COVER PLATE, WELDED TO COLUMN FOR FLOOR FINISHES SEE SHEET A-3 ANCHORING CEMENTCORE DRILL DETAIL CONCRETE SLAB 24" SECTION AT COMMUNITY TABLE 3 1 / 4 " 40 1 / 2 " 1 1 / 4 " 2 1 / 4 " 1 1/2" 42 " 1" PL-1 OR AS NOTED POCKET SCREWS WOOD BLOCKING INTO APRON 2 1 / 4 " 1 1/4" 1 1/2"1" 1/2" SHOP PLYWOOD SUBSTRATE 1-1/4" X 1-1/4" WOOD BLOCKING 1"EASED EDGE BIRCH APRON 3/16 x 3/16 CHAMFER ALL AROUND TOP BALTIC BIRCH TABLE SUPPORT POSTS WITH TOP AND BOTTOM PLATES, EQUAL SPACED - FINISH POWDER COAT (FLAT BLACK), POSTS ARE PROVIDED BY K.E.C. CORE DRILL TO SLAB BY G.C. PL-1 OR AS NOTED C1 SUPPORT POSTS WITH TOP AND BOTTOM PLATES, EQUAL SPACED - FINISH POWDER COAT (FLAT BLACK), POSTS ARE PROVIDED BY K.E.C. CORE DRILL TO SLAB BY G.C. C1 A-10 10 " 14 " PL-1 1" 96" 24 " 24 1 / 2 " 36"36"13"12" 10 " 14 " 14 " 10 " A-10 DETAILS DRINK STATION COUNTER 3/4" = 1'-0"A DRIVERS SHELF 1 1/2" = 1'-0"B RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 COMMUNITY TABLE 3/4" = 1'-0"C Reviewed by SAFEbuilt 12/12/2019 MAGNETIC LOOP BELOW CONCRETE DRIVE - CUT/REPLACE FINISH AS REQUIRED TO MATCH EXISTING MENU BOARD SEE D/A-11 SPEAKER POST SEE B/A-11 PIPE BOLLARD SEE F/ A-11 6 0 ° 3/4" COMMUNICATION CONDUIT TO COMMUNICATION PANEL PIPE BOLLARD SEE F/ A-11 5' - 0 " 1' - 3 " 8" 4'-0" 16'-6" 2' - 8 " SMOOTH SLOPED MORTAR CAP PAINTED PT-9 (2 COATS MIN.) 6" ø STANDARD STL.PIPE FILLED WITH CONCRETE AND PAINTED PT-9 (2 COATS MIN.) EXISTING PAVEMENT 18" ø CONCRETE FOOTING (2) NO. 6 BARS 12" LONG EACH WAY, WELD TO PIPE 1 1 / 2 " 9"9" 3" M I N . 3' - 0 " M I N I M U M 4' - 0 " 1 '-3 " 5 '-0 " MICROPHONE: 22 GA RED & BLACK 2 CONDUCTOR- AUDIO CABLE-OUTDOOR WIRE GROUND WIRE (BLUE OR BLACK) SPEAKER: 22 GA WIRE, COLOR IS GREEN & WHITE 3/4" COMMUNICATION CONDUIT TO RUN TO COMMUNICATION PANEL NOTE: SOLDER & INSULATE BOTH MAGNETIC LOOP CONNECTION FOR DUPLEX OPERATION IMPORTANT: AUDIO CABLE MUST BE SHIELDED, TWISTED PAIR AND THE CABLE FOR THE MICROPHONE MUST IN A SEPARATE CABLE. IF THE MICROPHONE WIRING IS IN A CABLE WITH OTHER PAIRS (BEING USED ELECTRICALLY IN THE SYSTEM), COMMUNICATION PROBLEMS WILL OCCUR. MAGNETIC LOOP (COORDINATE REQ'TS WITH J.J.'S CONSTRUCTION MANAGER) PAINT CURB PT-9 5" 3" 5'-2" 5"4'-4"5" 1' - 2 " 4' - 7 " 10 " 5' - 5 " TOP OF CURB 3/4" CONDUIT FOR 120 VAC POWER PREFABRICATED ANCHOR BOLT CAGE PROVIDED BY G.C. 6" STUB-UP FOR CONDUITS 1'-6" 1'-6" 3' - 0 " CONCRETE FOOTING BY G.C. VERIFY FROST DEPTH PER LOCAL CODE/ADJUST G.C. TO COORDINATE INSTALLATION OF EQUIPMENT PER THE MAIN STREET MENU SYSTEMS REQUIREMENTS (A PRODUCT OF THE HOWARD COMPANY, INC.) 10 1/2" LOOP SUPPORT 3/4" COMMUNICATION CONDUIT FROM COMMUNICATION PANEL MAGNETIC LOOP CONCRETE SPEAKER STAND 3' - 4 " 43 - 3 / 4 " 53-1/2" 7° 24-1/2"14-1/2"14-1/2" 1- 3 / 4 " 1- 7 / 1 6 " 3- 3 / 4 " READY ACCESS 131 GLAZING ROUGH OPENING = 53-3/4" W x 38" H MASONRY ROUGH OPENING = 54" W x 38-1/4" H TWO STANDARD WINDOW HEIGHTS: 37-3/4" H WITH 18"W x 31"H SERVICE OPENING 43-3/4" H WITH 18"W x 37"H SERVICE OPENING 4-13/16" MIN. DISTANCE FROM TOP OF SILL TO FINISHED FLOOR 4" VERIFY ALL SHOWN DIMENSIONS WITH READY ACCESS 131 SERIES WINDOW MANUFACTURER 2' - 1 0 " 3' - 0 " 3' - 8 1 / 4 " R O W O P E N I N G V. I . F . INSTALL TILES ON THE SILL RETURN TO THE WINDOW, SEE TYP. WINDOW ELEVATIONS DETAIL ON SHEET A-6 TILES ON 5/8" GYP. BD. TILES ON 5/8" GYP. BD. S.S. CORNER GUARD AROUND INTERIOR OPENING - SEE A-4 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 DRIVE THRU EQUIPMENT PLAN 1/2" = 1'-0"A DETECTION/SPEAKER ISOMETRIC N.T.S.C SPEAKER POST DETAIL N.T.S.B DRIVE THRU MENU BOARD N.T.S.D PIPE BOLARD 3/4" = 1'-0"F A-11 DETAILS DRIVE THRU DRIVE THRU WINDOW 3/4" = 1'-0"G Reviewed by SAFEbuilt 12/12/2019 STEAMER DRIVE EXISTING 3-STORY BUILDING PROPOSED JIMMY JOHN'S 1,337 S.F. EXISTING STAIRWELL EXISTING FIRE SPRINKLER ROOM DRIVE THRU WINDOW - SEE A-11 NEW MAGNETIC LOOP, TIE TO COMMUNICATION PANEL- SEE COM-1 EXISTING BLDG. OVERHANG EXISTING TRASH ENCLOSURE EXISTING TRASH ENCLOSURE EXISTING PARKING LOT NEW DRIVE THRU MENU,ORDER BOX, AND BOLLARDS, SEE A-11 16'-6" A-12 PLAN SITE NORTH RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 EXISTING SITE PLAN 1/16"=1'-0"A Reviewed by SAFEbuilt 12/12/2019 FIRE SPRINKLER ROOM 101 PREP 102 BACKROOM +10'-0" A.F.F. B.O. CEILING 100 DINING +10'-0" A.F.F. B.O. CEILING 104 WOMAN EF 2 3 1 EF 13 103 MEN 2 2 +8'-0" A.F.F. B.O. CEILING +8'-0" A.F.F. B.O. CEILING ±11'-2" A.F.F. B.O. JOISTS ±12'-6" A.F.F. B.O. DECK RTU 1 5 4 6 T 9 S1 100 8" Ø 87 16 " Ø 12" X 8" TYP. (6) S2 200 10 8 28 " X 1 6 " 26 " X 1 6 " 28"X16" 26"X16" 8" Ø 16"Ø 9S1 100 R2 1500 R2 1500 9 10 " Ø 10"Ø 9 S1 400 9 S1 400 9S1 400 87 11 ±11'-2" A.F.F. B.O. JOISTS ±12'-6" A.F.F. B.O. DECK 10"Ø 46"X10" 9 S1 400 10"Ø 44"X10" 16 " Ø 12 ~~ 2'-0" 6" 2" MANUAL AIR VOLUME DAMPER NEAR MAIN DUCT, TYPICAL DAMPER ARM CONTINUOUS ROD ON ALL DAMPERS OVER 12" DIA. MOUNT BOTTOM OF DUCT AT 10'-14' AFFATTACH RIGID DUCT TO FLEX DUCT WITH STRAP, TYP. BRANCH DUCT FLEXIBLE DUCT, MAX LENGTH 5'-0" TO BE USED IN VERTICAL DROP ONLY 90° BEND MUST BE RIGID ROUND DUCT. SECURE WITH (4) #10 SCREWSDIFFUSER T-RUNNER, TYPICAL ACOUSTIC CEILING TILE/ GRIDFIELD FABRICATED 6" SQUARE TO ROUND ADAPTOR. BRANCH DUCT MAIN DUCT ROUND BRANCH DUCT DUCT UNDER BEAM OR CROSSOVER RECTANGULAR MAIN / ROUND BRANCH DUCT RECTANGULAR BRANCH DUCT "B " 45°FL O W FL O W 45° EXISTING GIRDER OR BEAM RUN EXPOSE DUCT TIGHT TO DECK/UNDER GIRDER MANUAL VOLUME DAMPER ON FITTING, TYPICAL SADDLE TAP OR SPIN-IN FITTING ROUND BRANCH MANUAL VOLUME DAMPER RECTANGULAR MAIN DUCT MAIN DUCT BRANCH DUCT 1/4 OF "B" (TYPICAL) EXHAUST(MEN'S) RUBBER-IN-SHEAR VIBRATION ISOLATORS EXHAUST FAN FLEX. CONN. EXHAUST(WOMEN'S) EXISTING WALL 2ND FLOOR FRAMING SIDEWALL DIFFUSER. (S2) SEE SCHEDULE SHEET METAL BOOT TO MATCH DUCT - 45° ANGLE 24 GAUGE, ROUND SINGLE WALL SPIRAL SEAM DUCT. SEE DWG'S. FOR SIZES. NOTE: MATERIALS AND INSTALLATION SHALL BE PER SMACNA STANDARDSSUPPORT FROM STRUCTURE WITH 1/4" THREADED ROD 1" WIDE 22 GAUGE HANGER BAND MAX 12'-0" SPACING SEAL ALL AROUND WITH ELASTOMER GASKET 5" M-1 PLAN MECHANICAL MECHANICAL PLAN 1/4" = 1'-0"A TYPICAL CEILING DIFUSER 1" = 1'-0"2 DUCT CONNECTION DETAILS 1" = 1'-0"3 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 NORTH DAMPER S-2 R-1 S-1 FLEXIBLE DUCT SUPPLY AIR DIFFUSER SYMBOL DESCRIPTION RETURN AIR GRILLE 24x24 SUPPLY AIR DIFFUSER DUCT SMOKE DETECTOR EXHAUST AIR GRILLE TEMPERATURE SENSORT 1. HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH ALL TRADES. 2. CONTRACTOR TO COORDINATE WITH ARCHITECT FOR EXACT LOCATION OF AHU AND ALL REQUIREMENTS. 3. ALL THREAD FOR DUCT WORK SUPPORTS ARE TO BE FASTENED TO SOLID BLOCKING ABOVE DRYWALL. SD G E N E R A L N O T E S H V A C L E G E N D R O U N D D U C T S P E C I F I C A T I ON ALL EXPOSED DUCTWORK IN DINING AREA MUST BE ROUND SPIRAL. SQUARE DUCT IS NOT APPROVED. ROUND SPIRAL MUST BE 24 GAUGE, SINGLE WALL, GALVANIZED STEEL, SPIRAL LOCK SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT-TO-DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS LATEST EDITION. ALL EXPOSED ROUND DUCTWORK AND FITTINGS IN THE SALES AREA SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ("PAINT GRIP", "ZINC GRIP", OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. K E Y E D N O T E SK E Y E D N O T E S 1 2 3 4 5 6 7 8 9 10 11 PROGRAMMABLE THERMOSTAT WITH CLEAR LOCK BOX - COORDINATE RECESSED "J" BOX WITH ALL FINISH WALL MATERIALS/DEVICES. COORDINATE LOCATION OF CONDENSING UNITS ABOVE FREEZER/COOLER WITH DUCT LAYOUT PRIOR TO ORDERING. ROUTE RESTROOM EXHAUST TO ATMOSPHERE A MINIMUM OF 10'-0" FROM ANY FRESH AIR INTAKE- SEE 4/M-1. EXISTING UNIT INSTALLED ON SECOND LEVEL GROUND TERRACE, CONTRACTOR TO FIELD VERIFY EXACT LOCATION. CONDENSATE PIPING- SEE 7/P-2. ALL LINES MUST BE RUN WITHIN WALLS TO MOP SINK (TYP.). CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING OF PIPING PRIOR TO BID. DUCT SMOKE DETECTOR IN RETURN DUCT. DUCT MOUNTED BY MECHANICAL CONTRACTOR. RECTANGULAR DUCT TO BE RUN AS TIGHT TO BOTTOM CHORD OF JOISTS AS POSSIBLE. MECHANICAL CONTRACTOR TO COORDINATE DUCT INSTALLATION WITH EXISTING CONDITIONS AND OTHER TRADES PRIOR TO INSTALLATION. PROVIDE EXTERNAL MINERAL FIBER INSULATION TO ACHIEVE A MIN. R VALUE AS REQ'D BY CODE AND TO PREVENT CONDENSATION - ONLY APPROVED ABOVE DROPPED CEILING. SECTORIZED DAMPER FOR DIFFUSER- SEE 2/M-1 AND 3/M-1. TAP BOTTOM OF DUCT FOR CONNECTION. EXPOSED SPIRAL DUCT- SEE 1/M-1 - DUCTING TO BE RUN AS TIGHT TO BOTTOM CHORD OF JOISTS AS POSSIBLE. RUN DUCT ABOVE LIGHT FIXTURES BETWEEN SUPPORT CABLES. TRANSITION FROM RECTANGULAR TO SPIRAL DUCT MINIMUM 12" BEHIND FACE OF WALL, AS HIGH AS POSSIBLE. FIRE DAMPER AS REQUIRED. RESTROOM EXHAUST 1/4" = 1'-0"4 NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION.EXPOSED SPIRAL DUCT 1/4" = 1'-0"1 1 122 2 Reviewed by SAFEbuilt 12/12/2019 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 M-2 AND SCHEDULES MECHANICAL NOTES G E N E R A L N O T E S H V A C N O T E S G E N E R A L M E C H A N I C A L C O N D I T I O N SM E C H A N I C A L S P E C I F I C A T I O N S 1. AIR BALANCING A. CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT NEBB OR AABC CERTIFIED AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO P.S.S. PROJECT MANAGER AND LANDLORD OPERATIONS DIRECTOR FOR REVIEW. MIN. OUTDOOR C.F.M. AND INDOOR FAN C.F.M. SHALL BE PROVIDED AS SHOWN ON RTU SCHEDULE. 2. DUCTWORK A. INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WITH RECOMMENDED CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. FLEXIBLE DUCT SHALL NOT EXCEED 5'-0" IN LENGTH. MINIMUM SHEETMETAL THICKNESS SHALL BE 26 GA. B. ALL DUCT JOINTS LONGITUDINAL AND TRANSVERSE ARE TO BE SEALED USING 181A OR 181B LISTED TAPES AND MASTICS. MECHANICAL FASTENERS MUST BE USED TO FASTEN DUCTS. C. STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED FIVE (5) FEET FOR EACH DIFFUSER. SEAL ALL SHEETMETAL SCREW PENETRATIONS. D. PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EQUIPMENT AND CONNECTING DUCTWORK. E. ALL INSULATION, JOINING MATERIALS, SEALER, ETC.. SHALL HAVE A U.L. FLAME SPREAD CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT MORE THAN 50. 3. AIR DEVICES A. SUPPLY DIFFUSERS: (TITUS AS STANDARD) SHALL BE FURNISHED WITH BAKED WHITE ENAMEL FINISH, AND SHALL BE SELECTED FOR NECK VELOCITIES NOT EXCEEDING 800 FPM AND NOISE LEVEL OF NC-35 OR LESS. B. SUPPLY DIFFUSERS SHALL BE ROUND NECK, STEEL, MODEL TMSAA, SIZED USING CRITERIA INDICATED ABOVE FOR LAY-IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL CEILING AS INDICATED ON DWG. DIFFUSERS SHALL BE COMPLETE WITH ADJUSTABLE AIR PATTERNS AND VOLUME CONTROL DAMPERS. C. RETURNS SHALL BE 22 INCH SQUARE NECK ALUM. MODEL 50F AND/OR AS NOTED ON PLANS AND AIR DEVICE SCHEDULE. FACE VELOCITY OF RETURN REGISTERS SHALL NOT EXCEED 500 FPM. VOLUME CONTROL DAMPER NOT REQUIRED FOR RETURN INSTALLATION EXCEPT WHERE NOTED. D. COORDINATE LOCATION OF AIR DEVICES WITH LIGHTS, SPRINKLERS, SPEAKER, SMOKE DETECTORS, ETC. 4. EQUIPMENT A. REFER TO MECHANICAL PLANS FOR SPECIFICATIONS OF HVAC EQUIPMENT. B. ALL NEW EQUIPMENT SHALL BE EQUIVALENT TO THE SPECIFIED ITEM. ANY ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. C. NEW PLATFORM EQUIPMENT SHALL HAVE VIBRATION ISOLATION MOST SUITABLE FOR THE APPLICATION. D. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. E. COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS. F. GAS PIPING SHALL BE SCHEDULE 40 (ASTM-A120) BLACK STEEL WITH 300 lb. MALLEABLE IRON BANDED SCREWED OR WELD PATTERN FITTINGS AS APPLICABLE. G. ALL PIPING AND FITTINGS LOCATED OUTDOORS AND ABOVE GRADE SHALL BE CLEANED FREE OF RUST AND PAINTED. ALL FITTINGS TO BE MADE WITH PIPE JOINT COMPOUND. TEFLON TAPE NOT ALLOWED. H. ROOF CURBS BY CONTRACTOR. 5. CONTROLS A. PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON AN INDIVIDUAL BASIS. B. THE CONTRACTOR SHALL PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, TEST AND START-UP. C. CONTRACTOR SHALL SUPPLY AND PROGRAM CONTROLS TO SATISFY THE ENERGY CODE REQUIRED BY THE LOACAL ENERGY CODE. A 5°F DEADBAND SHALL BE PROGRAMMED WITH CAPABILITY OF 55°F HEATING AND 85° COOLING SETBACK TMEPERATURES. CONTROLS SHALL ALSO HAVE AN ACCESIBLE 2 HOUR OCCUPANT OVERRIDE. D. SCOPE OF WORK A. FURNISH AND INSTALL A COMPLETE BAS FOR ALL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS AND OTHER FACILITY SYSTEMS AS HEREIN DESCRIBED. THE BAS SHALL UTILIZE DIRECT DIGITAL CONTROL (DDC) AND ELECTRONIC ACTUATION. DDC SYSTEM SHALL PERFORM THE SEQUENCES OF OPERATION AND BE PROVIDED WITH THE CONTROL POINTS AS LISTED IN THIS SECTION. THE BASE SYSTEM DESIGN OF THE BAS SHALL INCLUDE THE FOLLOWING: 1. HEATING/COOLING RTU WITH DEMAND CONTROLLED VENTILATION. E. SYSTEM DESIGN A. IT IS THE DESIGN INTENT TO HAVE ONE DIGITAL CONTROLLER FOR EACH SPECIFIED CONTROL SYSTEM. SPLITTING THE CONTROL POINTS ASSOCIATED WITH A PARTICULAR SYSTEM BETWEEN DIGITAL CONTROLLERS SHALL NOT BE ALLOWED, EXCEPT FOR COMMON DATA POINTS SUCH AS OUTDOOR AIR TEMPERATURE. B. ALL DDC CONTROLLERS SHALL BE NETWORKED TOGETHER. C. ALL ROOFTOP UNITS WITH DDC CONTROLLERS TO BE NETWORKED TOGETHER ON A COMMON COMMUNICATION BUS AND SHARE A GLOBAL SCHEDULE. F. USER INTERFACE A. PROVIDE A MAIN LCD USER INTERFACE NETWORKED AND CAPABLE OF VIEWING ALL DDC CONTROLLERS. INTERFACE TO HAVE CAPABILITIES OF CHANGING SETPOINTS, VIEWING CONTROLLER ALARMS, AND SCHEDULING OCCUPANCY. G. RTU WITH DEMAND CONTROLLED VENTILATION A. SYSTEM DESCRIPTION 1. CONSTANT VOLUME ROOFTOP WITH DDC CONTROLLER 2. WALL-MOUNTED TEMPERATURE SENSOR IN THE SPACE 3. COMBINATION CO2 AND TEMPERATURE SENSOR MOUNTED NEAR THE RTU RETURN AND WIRED TO THE RTU CONTROLLER IAQ INPUT FOR DEMAND CONTROLLED VENTILATION OPERATION. B. SEQUENCE OF OPERATION 1. THE RTU CONTROLLER SHALL INCLUDE AN OCCUPANCY SCHEDULE ADJUSTABLE VIA THE WALL-MOUNTED LCD INTERFACE. 2. DEMAND CONTROLLED VENTILATION A. THE SPACE CO2 LEVEL SHALL BE COMPARED TO THE CO2 SETPOINT IN THE RTU CONTROLLER. IF THE READING IS BELOW THE CO2 SETPOINT, THE RTU SHALL MAINTAIN THE BASE VENTILATION RATE. IF THE READING IS AT/ABOVE SETPOINT, THE RTU CONTROLLER SHALL MODULATE THE OUTSIDE AIR DAMPER OPEN TO REDUCE THE CO2 READING IN THE SPACE. B. THE RTU SHALL MODULATE THE PREHEAT CONTROL TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. C. THE RTU'S ECONOMIZER CONTROL DETERMINES IF IT IS BENEFICIAL TO USE OUTSIDE AIR FOR FREE COOLING. THE ECONOMIZER SHALL OVERRIDE THE DEMAND CONTROLLED VENTILATION ALGORITHM TO MODULATE THE DAMPERS TO THEIR MAXIMUM POSITION. 1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. 2. ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3. THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER, SUPPLY DIFFUSERS, RETURN GRILLES, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THE CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS. 4. DRAWINGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAIL. 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 7. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS, LANDLORD'S SPRINKLER PLANS AND ALL OTHER TRADES. 8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT/OWNER. 10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THE CONTRACTOR SHALL BE REMOVED FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA. 11. ALL WORK AND EQUIPMENT SHALL BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE. 12. ALL WORK, INCLUDING INSIDE OF SUPPLY AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYSTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES. 15. ALL DESIGN SHALL INCORPORATE CURRENT ASHRAE METHODS. 16. WHEN EXISTING DUCTWORK IS UTILIZED, SIZES SHALL BE AS SHOWN ON DWGS. AS MINIMUM REQUIREMENT. A. DUCT SIZES SHOWN ARE SHEET METAL DIMENSIONS. NOT DUCT LINER. REFER TO MECHANICAL SPECIFICATIONS FOR DUCT INSULATION REQUIREMENTS. B. PROVIDE SINGLE WALL TURNING VANES @ ALL ELBOWS AND TEES PER SMACNA STANDARDS. C.DO NOT PROVIDE AIR EXTRACTORS OR SPLITTER DAMPERS WHICH PROTRUDE INTO RECTANGULAR TRUNK DUCTS. PROVIDE ROUND SPIN-IN FITTINGS FOR ROUND BRANCH DUCTS. D. ROUND BRANCH DUCTS ARE SAME SIZE AS DIFFUSER WHICH THEY SERVE. E. CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION, AND CONDITION OF ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, ETC. TO BE REUSED, RETAINED OR CONNECTED TO. F. CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. G. MAXIMUM FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 5'-0". REFER TO MECHANICAL SPECIFICATIONS ON SHEET M-2. H. CONTRACTOR SHALL PROCURE THE SERVICES OF A APPROVED NEBB OR AABC CERTIFIED AIR BALANCE & TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO TENANT PROJECT MANAGER AND/OR LANDLORD'S REPRESENTATIVE FOR REVIEW. I. BALANCING OF AIR DEVICES SHALL BE ACCOMPLISHED BY ADJUSTING BRANCH TAKEOFF DAMPER AT MAIN TRUNK DUCT. DAMPERS IN THE NECKS OF AIR DEVICES SHALL BE USED FOR FINAL TRIM ONLY, AND IN NO CASE FOR GREATER THAN 10% IF THE INDICATED VOLUME FOR THE INDIVIDUAL AIR DEVICE. J.DO NOT ATTACH ANYTHING TO THE UNDERSIDE OF THE ROOF DECK. ALL LOADS AND BRACING MUST BE ADEQUATELY SUPPORTED FROM THE BUILDING ROOF STRUCTURE. K. GAS PIPING SHOWN IS FOR LOW PRESSURE GAS IN THE THE BUILDING. CONTRACTOR SHALL VERIFY GAS PRESSURE PRIOR TO CONSTRUCTION. 2 PSIG MAY BE USED IF APPROVED BY AUTHORITIES. AND AS APPROVED BY JIMMY JOHNS. PROVIDE PRESSURE REDUCING VALVES AT EACH APPLIANCE AND VENT AS RECOMMENDED BY MFG. EXTEND NEW GAS LINE BACK TO EXISTING METER. VERIFY METER SIZE WITH UTILITY COMPANY. CONNECT NEW GAS LINE TO EXISTING MANIFOLD. L. ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY. 1. PROVIDE TESTING AND BALANCING FOR ALL AIR SYSTEMS. SUBMIT REPORTS TO ARCHITECT. 2. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL EQUIPMENT PRIOR TO ORDERING. 3. SEE ALL OTHER DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND CLARIFICATIONS OR WORK TO BE PERFORMED. 4. CONDENSATE FROM ROOFTOP EQUIPMENT SHALL DISCHARGE ONTO ROOF VERIFY WITH CITY CODE OFFICIALS. IF OBJECTIONABLE, EXTEND CONDENSATE PIPE TO APPROVED FLOOR RECEPTOR, OR EXTEND TO APPROVED EXTERIOR LOCATION. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES LOCATED IN THE CEILING GRID. 5. SEE ARCHITECTURAL ROOF PLAN AND DETAILS FOR LOCATION OF NEW ROOFTOP EQUIPMENT. 6. INSULATE LAST 5 FEET OF DUCT FROM TOILET ROOM EXHAUST DUCT WITH 1" THICK FIBERGLASS DUCT WRAP. PROVIDE VAPOR BARRIER. 7. DUCTWORK LAYOUT SHOWN IS RECOMMENDED. ADJUST TO COMPLY WITH CITY CODE REQUIREMENTS AND AS BUILT CONDITIONS. COOK GC220 1100 - - 115/1 N/A COOK GC220 1100 - - 115/1 N/A NOTES 1. EXHAUST FAN CONTROLLED BY BATHROOM LIGHT SWITCH (V.I.F.) 1RESTROOM REMARKSDRIVE TYPEELECTRICAL V/P FAN AMPS TOTAL STATIC PRESSURE (IN WC) ACTUAL CFM MANUFACTURER/ MODEL#QNTAREA SERVEDTAG NUMBER 1 E X H A U S T F A N S C H E D U L E RESTROOM EF 1 EF 2 LAY-IN T-BAR DUCT MTD. REMARKS - 3 BORDER ACCESSORIES 26 26 STEEL STEEL MAT'L. ADJ. PATTERN ADJ. S-2 S-1 MARK CEILING SIDE APPLICATION TITUS/TMS TITUS 300RL MFR. / MODEL FINISH RADIAL OPPOSED BLADE DAMPER OPPOSED BLADE DAMPER - DEVICES SHALL BE TITUS OR APPROVED EQUAL. SEE SPECIFICATIONS. - FLEXIBLE OR RIGID RUNOUT DUCT SIZE SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFICALLY SHOWN ON DRAWINGS. - MAXIMUM NC FOR ANY DEVICE WITH SPECIFIED CFM AND WIDE-OPEN DAMPER SHALL BE NO GREATER THAN NC25. - CEILING MODULE SHALL BE 24X24 UNLESS OTHERWISE NOTED. - AIR PATTERN SHALL BE 4-WAY UNLESS SHOWN OTHERWISE ON DRAWINGS. - DUCT MOUNTED AIR DEVICES SHALL BE INSTALLED AS SHOWN ON DETAIL. -26STEEL-R-1 TITUS -SIDEWALLSIDEWALL LAY-IN T-BAR-26STEEL-R-2 CEILING TITUS - D I F F U S E R A N D G R I L L E S C H E D U L E O.S.A. CALCULATIONS ROOM OCCUPANT LOAD PER 1000 S.F. TOTAL SQ. FT. TOTAL OCCUPANTS OUTDOOR AIR-CFM/PER. O.S.A. REQUIRED REMARKS DINING ROOM - PEOPLE 70 547 38 7.5 287.2 1 DINING ROOM - AREA 547 -0.18/SQ. FT.98.5 1 SUB TOTAL DINING 385.6 WITH ZONE AIR DIST. EFFECT (SUBTOTAL / 0.8) =482.0 KITCHEN 664 .7/SQ.FT.464.8 1 TOILET ROOMS 126 2 50 100.0 1 REMARKS 1. TOTAL SQUARE FOOTAGE BASED ON NET FLOOR AREA PER IMC TABLE 403.3 FOOTNOTE a AND IMC CHAPTER 2 DEFINITIONS REQUIRED PROVIDED 1046.8 1047 R O O F T O P H V A C U N I T ( R T U ) S C H E D U L E TAG AREA SERVED COOLING CAPACITY GAS HEATING CAPACITY SUPPLY FAN COMPRESSOR(S)FILTER ELECTRICAL DATA REMARKS TONS TOTAL MBH SENS MBH (S)EER STAGE INPUT MBH OUTPUT MBH AFUE CFM O.S.A. CFM MOTOR (H.P.)TYPE QUANTITY TYPE THICKNESS (IN.)VOLTS PHASE MOCP MCA WEIGHT (LBS.)MANUFACTURER MODEL RTU-1 JIMMY JOHN'S 7.5 97.3 77.1 12.6 2 200 116.8 80 3000 1047 1 SCROLL 1 DISPOSABLE 2 208 3 50 42 1300 TRANE YHC-092 1,2,3,4,5,6 REMARKS: 1. EXISTING UNIT - FIELD VERIFY EXACT LOCATION. 2. PROVIDE WITH SINGLE DRY BULB ECONOMIZER AND BAROMETRIC RELIEF DAMPER. 3.ALL RTUS TO BE FURNISHED HACR CIRCUIT BREAKER, DISCONNECT AND 120V GFCI SERVICE OUTLET. ELECTRICAL CONTRACTOR TO MAKE FIELD CONNECTIONS TO ALL UNITS. 4.ALL RTUS SHALL BE FURNISHED WITH SMOKE DETECTORS; IN RETURN DUCT. 5. FURNISH AND INSTALL REMOTE SENSORS IN RETURN AIR DUCT AND SEVEN DAY PROGRAMMABLE THERMOSTATS FOR EACH RTU IN OFFICE. 6. ALL RTUS SHALL BE INSTALLED WITH FULL SIZE SUPPLY AND RETURN DROPS. Reviewed by SAFEbuilt 12/12/2019 Provide TAB report to the Building Dept. by final inspection. FIRE SPRINKLER ROOM 3412 20 1 LAV 1 WC 1 WH 17 249 8 8 WC 1 LAV 1 3 3 17 14 13 16 19 21C 21D 100 DINING 101 PREP 104 WOMAN 102 BACKROOM 103 MAN TP 14 10 FIRE SPRINKLER ROOM 100 DINING 101 PREP 104 WOMAN 8 102 BACKROOM 17 FS 2 8A FD 2 SQ 21D 20 16 18 6 WC 1 LAV 1 FD 1 SQ FCO SQ 11 1619 TP 14 WC 1 LAV 1 103 MAN 16 FS 121C 18 5 9 5 5 FD 2 RD FS 1 EXST. C.O. 15 16 19 FCO SQ11 5 EXST. C.O. P-1 PLANS PLUMBING DOMESTIC WATER PLAN 1/4" = 1'-0"A SANITARY WASTE PLAN 1/4" = 1'-0"B RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 NORTHNORTH G E N E R A L N O T E S NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. PROVIDE 1/2" CW LINE WITH SHUT-OFF VALVE AT + 81" A.F.F. THRU WALL TO CARBONATOR (MOUNTED ABOVE BAG-AND-BOX). CONNECTIONS TO CARBONATOR TO BE PROVIDED BY BEVERAGE COMPANY. COCA-COLA TO PROVIDE 3/8" SHUTOFF TEE ON NON-CARBONATED WATER LINE WITHIN SODA CABINET. PLUMBER TO CONNECT TEA BREWER TO 3/8" SHUTOFF USING BRAIDED METAL HOSE. WATER LINE TO BE FED THROUGH THE CHASE WITH SYRUP LINES. 1/2" WATER LINE STUB OUT AT +12" A.F.F. 1/2" SOFT ANNEALED COPPER FROM TRAP PRIMER ABOVE CEILING DOWN IN WALL U/G TO F.D. CONNECT TO EXISTING VENT STACK. WHEN TWO OR MORE VENT PIPES CONVERGE, EVERY DRY VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6 INCHES ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. CONNECT TO EXISTING 4" KITCHEN WASTE LINE AT 1/8" PITCH MIN. , V.I.F. EXACT LOCATION. PLATFORM MOUNTED WATER HEATER WITH DRAIN PAN - SEE DETAIL 5/P-2. CONNECT TO EXISTING 1-1/2" WATER SERVICE STUB, VERIFY EXACT LOCATION. ALL EQUIPMENT TO BE INSTALLED ABOVE NEW HUNG CEILING TO CONCEAL EQUIPMENT. PROVIDE 6" PVC UNDER THE SLAB FOR SODA DISPENSER FROM BAG-N-BOX. VERIFY LOCATION IN ORDER FOR THE SODA LINES TO RUN TO DESIGNATED LOCATION WITHIN SODA CABINET AND BAG-N-BOX. COORDINATE WITH SODA VENDOR AND ALL WASTE LINES. SEE 11/P-2 FOR TERMINATION DETAIL. ROUTING OF HOT AND COLD WATER LINES TO BE COORDINATED WITH MECHANICAL. F.C.O. - COORDINATE WITH NEW FLOOR FINISHES. CONTRACTOR TO FIELD VERIFY CORRECT CONNECTION (3" OR 4") AND ORDER APPROPRIATE MODEL. WATER FILTER TO BE MOUNTED ON WALL AT 8'-0" A.F.F. PROVIDE SHUT OFF VALVE AT EACH SIDE OF FILTER. RECESS ALL SUPPLY LINES.10/P-2 STUB UNFILTERED CW LINE FROM WALL AT +67" A.F.F. - PROVIDE METAL BRAIDED HOSE CONNECTING THE WATER SHUT OFF VALVE TO THE ICE MACHINE FOR COOLING UNIT WITH BACK FLOW PREVENTER. PROVIDE IN-LINE ASSE 1022. FILTERED WATER LINE TO BE STUBBED OUT AT +67" A.F.F. TO SHUT OFF VALVE AND CONNECTED WITH A BRAIDED METAL HOSE, RUN WATER LINE IN WALL. CONNECT TO EXISTING 4" GREASE WASTE LINE AT 1/8" PITCH MIN. , V.I.F. EXACT LOCATION. INSTALL WALL CLEAN-OUT 12" A.F.F. CENTERED. NOT USED. 2" HORIZONTAL VENT LINE. REVERSE GRADE TO FIXTURE SERVED. PROVIDE DRAINAGE PATTERN FITTINGS AT HORIZONTAL VENTS AS REQUIRED. 2 3 4 5 6 7 8 9 10 14 12 11 13 15 K E Y E D N O T E S 1 16 17 18 1. ALL FLOOR SINKS, FLOOR DRAINS, FLOOR CLEANOUTS, AND GREASE TRAP SHALL BE INSTALLED SO THAT TOPS ARE FLUSH WITH FLOOR FINISH TILE. 2. CONTRACTOR TO COORDINATE / VERIFY EXACT LOCATIONS FOR ALL FLOOR FIXTURES PRIOR TO SAWCUTTING. 3. COORDINATE WATER LINES WITH ELECTRICAL CONTRACTOR PIPING SHALL NOT BE ROUTED OVER ELECTRICAL PANEL OR EQUIPMENT. 4. ALL BACKFLOW PREVENTERS SHOULD BE INSTALLED ABOVE THE KITCHEN OR RESTROOM DROP CEILING. IF BFP CANNOT BE INSTALLED ABOVE CEILING, IT MUST BE INSTALLED ABOVE THE MOP SINK, UNDER THE WATER HEATER PLATFORM. BFP SHOULD NOT INTERFERE IN ANY WAY WITH THE OPERATION OF THE KITCHEN. IF AN EXISTING BACKFLOW PREVENTER IS IN A LOCATION OTHER THAN WHAT IS SHOWN ON THESE DRAWINGS, CONTACT THE JIMMY JOHN'S CONSTRUCTION DEPARTMENT IMMEDIATELY FOR DIRECTION ON HOW TO PROCEED 5. ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. NO WATER LINES MAY RUN ALONG WALL. ALL EXISTING MUST BE MOVED 12" OFF OF WALL. IF CANNOT BE MOVED, LINE MUST BE FRAMED AROUND AND FINISHED PER WALL STYLE. ANY APPROVED EXPOSED DRAIN LINES MUST BE COPPER. 6. NOT USED. 7. G.C. TO CONFIRM FLOOR DRAIN AND PVC CHASE INSIDE SODA CABINET ARE UNDER COKE MACHINE. 8. IF REQUIRED, GREASE TRAP RELIEF VALVE ACCESS MUST BE SQUARE SHAPED DIAMOND METAL PLATED LID PAINTED - TGIC POWDER COAT - COLOR: ANSI 61 GREY. 9. IF A FLOW CONTROL DEVICE IS REQUIRED AT GREASE TRAP, IT MUST BE INSTALLED UNDERGROUND WITH AN ACCESS PANEL FLUSH WITH FINISHED FLOOR. LID MUST BE A METAL DIAMOND TREAD PLATE PAINTED (TGIC POWDER COAT- ANSI 61 GREY) TO MATCH GREASE TRAP. 2 2 PROVIDE BACKFLOW DEVICES FOR ALL SUBMERGED INLETS SOFT DRINKS CARBONATORS, WATER SOFTENERS, AND BEVERAGE DISPENSERS. BACKFLOW DEVICES ON WATERLINES SUBJECT TO BACK PRESSURE OR CONTINUOUS PRESSURE MUST BE EQUIPPED WITH BACKFLOW PREVENTERS THAT ARE DESIGNED FOR CONTINUOUS PRESSURE. 2 2 2 Reviewed by SAFEbuilt 12/12/2019 8' - 0 " A . F . F . FILTERED WATER-OUTLET WATER SUPPLY-INLET 8' - 3 / 4 " A . F . F . ROOFING FLASHING ROOFING 5'-0" MIN. FROM INSIDE WALL NOTE: ALL PIPES FULL SIZE OF UNIT OUTLET TO APPROVED RECEPTACLE PIPE SIZE SAME AS UNIT CONDENSATE DRAIN OPEN PIPE TO ATMOSPHERE B. 0.5 X STATIC PRESSURE IN PAN (INCHES). A. STATIC PRESSURE IN PAN (INCHES) UNIT AC CONDENSATE DRAIN B A 6" VENT PITCH AT 1/8"/FT FLOOR DRAIN 4" TRAP SEDIMENT BUCKET CONNECT TO TRAP PRIMER VENT TO SAN. WASTE MAIN 1" MIN AIR GAP OR AIR BREAK ICE MAKER DEEP SEAL TRAP DRAIN FROM COOLING UNIT FLOOR DRAIN FOR ICE BIN FLOOR DRAIN WITH FUNNEL 4" HIGH 18" RUBBER MEMBRANE NICKEL BRONZE GRATE AIR GAP 1" MIN. CONNECT TO TRAP PRIMER (AT CONDENSATE LINE DRAIN ONLY) 1. SPACE BLOCKING STANDS AT 6'-0" INTERVALS ON ROOF. 2. FOLD UP END OF SLIP SHEET AND NAIL TO BLOCK CONDENSATE PIPE NOTE: 4x6 "WOLMANIZED" BLOCKING - MASTIC TO ADDITIONAL ROOFING SHEET METAL STRAP WITH 1/4" DIA. x 2" LAG EACH SIDE, ALLOW FOR MOVEMENT RESTROOM LAV HAND SINKWALL HUNG LAV [110° F] TEMPERED WATER 1/2" THERMOSTATIC TEMPERING VALVE SEE SPECIFICATIONS 1/2" HW [140° F] SUPPLY FINISHED FLOORFINISHED FLOOR 1 1/4" O.D. TAILPIECE 1 1/4" O.D. WASTE 1/2" CW SUPPLY NOTE: APPLICABLE TO ALL LAVS/HAND SINKS [110° F] TEMPERED WATER 1/2" THERMOSTATIC TEMPERING VALVE SEE SPECIFICATIONS 1/2" HW [140° F] SUPPLY 1 1/4" O.D. TAILPIECE 1 1/4" O.D. WASTE 1/2" CW SUPPLY FINISHED FLOOR 2" FLOOR SINK TO GREASE LINE MIN. 2" AIR GAP RIGID CONNECTION CW HW STAINLESS STEEL DRAIN PAN, 1 1/2" DEEP WITH A 1" MINIMUM DRAIN PRESSURE TEMP. RELIEF VALVE DISCHARGE TO MOP SINK DRAIN VALVE CODE APPROVED VACUUM BREAKER REQUIRED AT ALL ELEVATED W.H. CONNECT TO SIDE OF MAIN. DO NOT CONNECT FROM TOP OR BOTTOM WATER HEATER NO VALVES OR DEVICES TO BE INSTALLED BETWEEN EXPANSION TANK AND THE WATER HEATER AS PER CODE. PROVIDE INTEGRAL HEAT TRAPS ALL DRAIN LINES AND PRESSURE RELIEF LINES TO BE RECESSED IN WALL AND STUBBED OUT DIRECTLY ABOVE MOP SINK. INSTALL THERMAL EXPANSION TANK 1" PIPE INDIRECTLY WASTED TO MOP SINK DROP CEILING 8 18 16 3" HOLE PVC CAP - CUT 1" TALL TIGHT TO TILE/CONCRETE 6" PVC PIPE STUBBING 3/4" ABOVE FINISH FLOOR6" PVC CHASE CONC. SLAB SYRUP LINES FIGURE 1.0 FILL IN HOLE WITH FOAM & WHITE SILICONE AROUND SYRUP LINES SEE FIGURE 1.0 POLISHED CONC. SLAB 1"90° ANGLE TILE FLOOR P-2 AND SCHEDULES PLUMBING DETAILS RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 (3) COMPARTMENT SINK DETAIL N.T.S.1 TYPICAL VENT THRU ROOF N.T.S.6 FLOOR DRAIN DETAIL N.T.S.2 TYPICAL UNIT CONDENSATE PIPING N.T.S.7 ICE MAKER DRAINAGE PIPING DETAIL N.T.S.3 FLOOR DRAIN WITH FUNNEL DETAIL N.T.S.4 CONDENSATE SUPPORT SIMILAR N.T.S.8 LOCAL MIXING VALVE DETAIL N.T.S.9 WATER FILTER DETAIL N.T.S.10 PLUMBING FIXTURE SUPPLIER KEC DESIGN 301 MERCURY DRIVE SUITE 1 CHAMPAIGN, IL 61822 PHONE: 217.356.1640 FAX: 217.356.1661 EMAIL: projects@kecdesign.com WATER HEATER DETAIL N.T.S.5 - -- -SIOUX CHIEF - 8706/ 870-B/ 874-4C WALL CLEANOUTWCO SMOOTH, STAINLESS STEEL ACCESS COVER FLOOR SIOUX CHIEF - 834-4HNQ -- -- WATER FILTER 3M - BREW125-MS -- -1/2" FAUCET 140°2"3/4" 3"3/4" UNIVERSAL STAINLESS - CHF-04FAUCET GOOSENECK FAUCET. UNIVERSAL STAINLESS - EHS-1 110°HAND SINK 1-1/2"1/2" 1-1/2"1/2" TEMP REMARKS VTW UTILITIES CW HW MANUFACTURER - MODEL NOITEMMARK 110° FLOOR DRAIN SIOUX CHIEF- 832-4DHNR 2"-4"- ZURN - Z5354 OR EQUAL 1-1/2"1/2" 1-1/2"1/2" CANPLAS - FLANGELESS FLOOR SINK - 394708 2"-3"-FLOOR SINK PPP - P1-500 W/ADAPTER OR EQUAL 2"-3"1/2"TRAP PRIMER FLOOR DRAIN IS TO BE FLUSH WITH FINISH FLOOR.SIOUX CHIEF - 832 - 4DHNR - 863 - FN 2"-3"- CANPLAS - FLANGELESS FLOOR SINK - 394723 2"-3"-FLOOR SINK FLOOR DRAIN ZURN - Z1996-SF CLEANOUT NOTE: THERE WILL BE ABSOLUTELY NO SUBSTITUTIONS ALLOWED FOR ANY PLUMBING PRODUCTS AS SPECIFIED. THIS INCLUDES ALL ZURN PRODUCTS. P L U M B I N G F I X T U R E S C H E D U L E POLISHED NICKEL BRONZE TOP, TOP TO BE INSTALLED FLUSH WITH FINISHED FLOOR. FIELD VERIFY CORRECT CONNECTION (3" OR 4") AND ORDER APPROPRIATE MODEL. 834-3PF (3") ICED TEA BREWER MOP BASIN ZURN - Z1996-24 SEE NOTE 2 FOR THERMOSTATIC MIXING VALVES REQUIREMENTS. FURNISH W/ZURN Z812B1 FAUCET WITH VANDAL RESISTANT AERATOR AND GRID DRAIN. PROVIDE TRU-BRO LAV GUARD. SEE NOTE 2 FOR THERMOSTATIC MIXING VALVES REQUIREMENTS. INTEGRAL BFP AND VACUUM BREAKER MOUNT ABOVE CEILING FCO SQ FD 2 RD FD 2 SQ LAV 1 WC 1 FS 1 FS 2 TP 1 17 19 20 34 49 WALL-MOUNT WITH 1/2" IPS FLANGED FEMALE INLET, VACUUM BREAKER SPOUT, PAIL HOOK, 3/4" HOSE THREAD, LEVER HANDLES AND ROUGH CHROME FINISH. PROVIDE HOSE BIB VACUUM BREAKER FOR SPRAYER. VERIFY INDIRECT WASTE AND GREASE TRAP - SEE 1/P2. FAUCET MUST BE INSTALLED AT 3'-0" AFF AND CENTERED ON MOP SINK. 9"x9" FLOOR SINK,3" OUTLET. A.R.E. BUCKET, BOTTOM DOME STRAINER. - TOP OF FLOOR SINK IS TO BE FLUSH WITH TOP OF FLOOR TILE. 12"x12" FLOOR SINK, 3" OUTLET. THREE QTR FLOOR GRATE, A.R.E. BUCKET, BOTTOM DOME STRAINER. - TOP OF FLOOR SINK IS TO BE FLUSH WITH TOP OF FLOOR TILE. TYPE "N" STAINER. PROVIDE WITH COMPLETE BODY ASSEMBLY WITH TRAP PRIMER CONNECTION - SEE 2/P2. TOP TO BE INSTALLED FLUSH WITH FINISHED FLOOR HANDICAP WALL HUNG LAVATORY SEE DETAIL 10/P-2 CANPLAS - THREE QTR FLOOR GRATE - 394712B 834-4PF (4") FLOOR SIOUX CHIEF - 834-4HNR -- -- CLEANOUT POLISHED NICKEL BRONZE TOP, TOP TO BE INSTALLED FLUSH WITH FINISHED FLOOR. FIELD VERIFY CORRECT CONNECTION (3" OR 4") AND ORDER APPROPRIATE MODEL.834-3PF (3") FCO RD 834-4PF (4") SQUARE ROUND FLOOR DRAIN SIOUX CHIEF- 832-4DHNQ 2"-4"- FD 1 RD FD 1 SQ. TYPE "N" STAINER. PROVIDE WITH COMPLETE BODY ASSEMBLY WITH TRAP PRIMER CONNECTION - SEE 2/P2. TOP TO BE INSTALLED FLUSH WITH FINISHED FLOOR FLOOR DRAIN IS TO BE FLUSH WITH FINISH FLOOR.SIOUX CHIEF- 832 - 4DHNQ - 863 - FN 2"-3"-FLOOR DRAIN SQUARE ROUND SQUARE ROUND -CARBONATOR --1/2"COCA COLA16D 2"-4" FURNISH WITH ZURN OPEN FRONT SEAT MODEL Z5955SS STOP VALVE HANDICAP ZURN Z5560 1/2"WATER CLOSET 21C -ICE-MAKER -- -(2) 1/2"HOSHIZAKI -F-1002MWJ-C -- -3/8"BUNN-O-MATIC - TB6Q-0301 WATER COOLED ICE MAKER. PROVIDE W/ HOSHIZAKI B-300PF BIN - SEE 3/P2. TEE OFF ICE/BEVERAGE UNIT WATER SUPPLY WITH SHUT-OFF VALVE 140°VEGETABLE PREP SINK W/ 1- 18" DRAIN BOARD ELKAY - 14-1C16x20-L-18x VERIFY INDIRECT WASTE FS -1/2" INTO1/2" MIXING FAUCET WITH 12" NOZZLEFAUCET ZURN - Z842H1-15F 21D NOTES 1. ALL PLUMBING FIXTURES TO BE FULLY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES ACT OF 1990. FIXTURES AND THEIR INSTALLATION SHALL ALSO COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) PUBLICATION A117.1 - PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE AND/OR GOVERNING CODES. - ALL PLUMBING FIXTURES EQUIPMENT, TRIM, & FITTINGS SHALL COMPLY WITH CITY REQUIREMENTS, AND FEDERAL REGULATIONS AND CODES, INCLUDING, BUT NOT LIMITED TO, WATER AND ENERGY CONSERVATION CODES. THE SCHEDULED AND/OR SPECIFIED PLUMBING FIXTURES AND EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT DO NOT COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR SHALL PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTINGS. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTOR'S BID INCLUDES ALL COSTS NECESSARY TO MEET ALL REGULATIONS & CODES. 2. PROVIDE THERMOSTATIC MIXING VALVE AT ALL LAVATORIES AND HAND SINKS. PROVIDE ZURN TMV-1, 1 TO 15 GPM, NOT TO EXCEED 3 PSI, W/ UNION STOP CHECK INLETS, AND REMOVABLE STAINLESS STEEL STRAINERS, DIAL THERMOMETER AND DISCHARGE VALVE. SUPPLIES 110^F. 3. ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY. 4. REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS SODA CHASE TRMINATION DETAIL N.T.S.11 140°-1/2"1/2" FAUCET ZURN - Z842H1.0002 FAUCET ZURN - Z842H1-15F 3 COMPARTMENT SINK W/ 2- 24" DRAIN BOARDS INDIRECT REMARKS LWTSTORAGE EWTMANUFACTURER AND MODEL NO. WH-1 MARK DEG. (GALLONS) CAPACITY DEG. F F ELECTRIC ELEMENT KW GPH REC. VOLT STAGESPH A.O.SMITH 50 140 74 20812.0 13 DEL-50D 40 (1) 18 KW PROVIDE INTEGRAL HEAT TRAPS - SEE 5/P-2 E L E C T R I C W A T E R H E A T E R S C H E D U L E "LOW BOY" ELKAY - 3C18x18-2-24x-L TO FS 1 Reviewed by SAFEbuilt 12/12/2019 WATER FILTER MOP SINK ICE MACHINE CARBONATOR MOP SINK FD 1 SQ 3 COMP SINK FS 2 ICE MAKER WCO TP 1 HAND SINK FCO SQ WCO WC 1 WCO WH 1 CONNECT TO EXISTING WATER LINE AND METER, UPGRADE IF NECESSARY,V.I.F. WC 1 WC 1 LAV 1 LAV 1 3/4" DRINK MACHINE FD 2 SQ LAV 1 WC 1 LAV 1 WCO CONNECT TO EXISTING WASTE LINE V.I.F. HAND SINK WCO VEGGIE SINK 3 COMP SINK FS 1 HAND SINK F VEGGIE SINK 1/2" 1/2" 1/2" 1/2" 1/2" 1-1/4" TP 1 FS 1 1/2"1/2" 1" 1/2" 1/2" 1/2" 1/2"1/2" 1/2" 1/2" 1/2" 1/2" 1-1/4" 1/2" 1-1/4" 1/2" 1" 1/2"1/2" G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G WL G W L G W L G WL G WL G WL G WL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL GWL FCO SQ FD 2 RD CONNECT TO EXISTING GREASE LINE V.I.F. 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" CONNECT VENT LINES TO EXISTING VENT STUB-UP, V.I.F. CONNECT TO VENT STACK. COORDINATE WITH SHELL DRAWINGS FOR EXACT LOCATION. HAND SINK 1/2" HAND SINK WCO 1. SEE RESTAURANT EQUIPMENT SCHEDULE ON THE ARCHITECTURAL PLANS FOR EQUIPMENT PROVIDED BY OTHERS. THIS CONTRACTOR SHALL CONNECT WASTE, VENT, AND WATER TO EQUIPMENT FURNISHED BY OTHERS AND THIS CONTRACTOR SHALL INSTALL FAUCETS AND MISC. FITTINGS FOR A COMPLETE INSTALLATION. 2. ALL PLUMBING LINES MUST BE RECESSED WITHIN WALL CAVITIES UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. 3. CONNECT NEW DOMESTIC WATER TO EXISTING LINE. INSTALL BALL VALVE AS SHOWN. 4. EXTEND PLUMBING VENT UP THRU ROOF TO APPROVED VENT TERMINATION. LOCATE MINIMUM OF 15 FEET FROM ANY O.A. INTAKE AT THE CONDENSER UNITS. 5. ALL EXPOSED PIPING TO PLUMBING FIXTURES SHALL BE CHROME PLATED. STOPS SHALL BE PROVIDED WITH REMOVABLE TYPE HANDLES. S A N I T A R Y W A S T E I S O M E T R I C N.T.S.B D O M E S T I C W A T E R I S O M E T R I C N.T.S.A P-3 ISOMETRICS PLUMBING RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 G E N E R A L N O T E S 1 Reviewed by SAFEbuilt 12/12/2019 MEP-1 GENERAL NOTES MECH./ELEC./PLUMB. RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 1. THE M/E/P CONTRACTORS SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL ARCHITECTURAL, ALL STRUCTURAL, ALL MECHANICAL, ALL ELECTRICAL, ALL PLUMBING, AND ENTIRE PROJECT MANUAL. ELECTRICAL CONTRACTOR SHALL ACKNOWLEDGE AND INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS PERTINENT TO THE COMPLETION OF THE ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE ELECTRICAL WORK WITH THE INSTALLATION OF WORK BY ALL OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE ELECTRICAL INSTALLATION. ALL OF THE ABOVE SHALL BE INCLUDED IN THE SCOPE OF WORK AT NO ADDITIONAL COST TO THE OWNER. 2. THE M/E/P CONTRACTORS SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS, VISIT THE SITE OF THE WORK, AND FULLY INFORM HIMSELF AS TO ALL CONDITIONS AND MATTERS THAT CAN, IN ANY WAY, AFFECT THE WORK OR THE COST THEREOF, SHOULD THIS CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS OR BE IN DOUBT AS TO THEIR MEANING, NOTIFY THE ARCHITECT/ENGINEER AT ONCE, IN WRITING, OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN ELECTRICAL WORK AND THE WORK OF OTHER TRADES PRIOR AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BID. LACK OF SUCH NOTIFICATION SHALL BE CONSTRUED TO INDICATE NO DISCREPANCIES OR CONFLICTING EXIST. ADDITIONAL COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO COMPLY WITH THESE REQUIREMENTS. 3. THE DRAWINGS INDICATE THE DIAGRAMMATIC INTENT, GENERAL CHARACTER, REQUIREMENTS AND LOCATION OF THE WORK SHOWN AND INCLUDED. THE WORK INDICATED BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 4. THE CONTRACTOR IS REQUIRED TO BID, AS SPECIFIED, ON THE DRAWINGS WITHOUT DEVIATION. THIS CONTRACTOR IS INVITED TO SUBMIT SUBSTITUTIONS FROM THE BASE BID, ONLY IF THE SUBSTITUTIONS ARE APPROVED BY THE OWNER AND ENGINEER/ARCHITECT PRIOR TO SUBMITTING THE BID. 5. IT IS THE INTENT OF THESE DOCUMENTS THAT THE M/E/P CONTRACTOR PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS FOR THE COMPLETE INSTALLATION OF ALL WORK SHOWN ON THE PLANS AND/OR DESCRIBED HEREIN, INCLUDING ALL DEVICES, CONTROLS AND APPURTENANCES REQUIRED TO SET NEW SYSTEMS INTO OPERATION. 6. THE CONTRACTOR SHALL VERIFY ALL MOUNTING, ALL ARRANGEMENTS, HEIGHTS AND LOCATIONS PRIOR TO ROUGH-IN. ANY MENTION OF A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT FURNISHED OR THE OTHER TRADES WORKING IN THE SAME AREA. NO ADDITIONS TO THE CONTRACT SUM WILL BE PERMITTED FOR ITEMS INSTALLED IN WRONG LOCATIONS, IN CONFLICT WITH OTHER WORK, ETC. 7. SHOULD CONDITIONS NECESSITATE ANY REARRANGEMENTS, OR IF DUCTWORK CAN BE RUN TO BETTER ADVANTAGE, PREPARE AND SUBMIT SHOP DRAWINGS SHOWING THE CHANGES BEFORE PROCEEDING WITH THE WORK. IF SUCH CHANGES ARE APPROVED BY ARCHITECT/ENGINEER, THEY SHALL BECOME A PART OF THE CONTRACT AFTER THEIR APPROVAL. 8. UPON COMPLETION OF THE WORK, THE CONTRACTORS SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, CLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. THE CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC. FOR EQUIPMENT INSTALLED BY THE CONTRACTOR INCLUDING EQUIPMENT FURNISHED BY THE OWNER. THE ABOVE SHALL ALSO APPLY TO ALL EQUIPMENT FURNISHED BY OTHERS AND UNPACKED OR REMOVED FROM CARTON, BY THE CONTRACTORS. 9. THE M.E.P. CONTRACTORS IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNPACKING STORING SETTING IN PLACE, AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR. 10. THE M.E.P. CONTRACTORS SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, INSPECTIONS AND TAXES APPLICABLE TO THIS DIVISION AND SHALL BE INCLUDED IN THE BASE BID AS PART OF THIS CONTRACT. 11. THE M.E.P. CONTRACTORS SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE FULL YEAR AFTER FINAL ACCEPTANCE BY THE ARCHITECT/ENGINEER AND OWNER. 12. M.E.P. CONTRACTORS SHALL FURNISH CONTRACT RECORD DOCUMENTS TO THE ARCHITECT/ ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE CONTRACT RECORD DOCUMENTS SHALL INDICATE THE DIAGRAMMATIC INSTALLED CONDITION AND BE IN REPRODUCIBLE DRAWING FORM. 13. THE WORK INSTALLED SHALL BE IN ACCORDANCE WITH ALL CITY CODES AND THE LOCAL UTILITY COMPANY'S REQUIREMENTS. 14. ALL EQUIPMENT/DEVICES SHALL BE NEW AND/OR FIRST QUALITY AND IS TO BEAR THE APPROPRIATE UL OR CSA APPROVED LABELS FOR SPECIFIC PURPOSE. 15. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM AS REQUIRED. 16. ALL THERMOSTATS SHALL BE MOUNTED AT +60" ABOVE FINISHED FLOOR (UNLESS OTHERWISE SPECIFIED). THERMOSTATS SHALL NOT INTERFERE WITH SHELVING, VENDING MACHINES, OTHER FIXTURES OR CONTROLS. 17. THE CONTRACTOR SHALL BE LICENSED, BONDED, INSURED AND CAPABLE OF PERFORMING QUALITY WORKMANSHIP. THIS CONTRACTOR GUARANTEES ALL OF HIS WORK AND MATERIALS FOR A PERIOD OF ONE (1) FULL YEAR AND FINAL ACCEPTANCE BY THE OWNER AND ENGINEER. 18. THE MECH & PLMG CONTRS SHALL SUBMIT SHOP DRAWINGS PRIOR TO THE START OF INSTALLATION FOR OWNER/ARCHITECT/ENGINEER APPROVAL. 19. THE M/E/P CONTRACTORS SHALL FURNISH AS-BUILT DRAWINGS TO THE OWNER/ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE AS-BUILT DRAWINGS SHALL BE SUBMITTED IN REPRODUCIBLE FORM. 20. THE M/E/P CONTRACTORS SHALL BE RESPONSIBLE FOR THE STARTUP OF ALL HEATING, VENTING, AND AIR-CONDITIONING EQUIPMENT. 21. THE M/E/P CONTRACTORS SHALL PROVIDE A COMPETENT OPERATING TECHNICIAN TO INSTRUCT THE OWNER IN THE OPERATION AND MAINTENANCE OF THE NEW EQUIPMENT. 22. DO ALL CUTTING AND PATCHING (TO ORIGINAL STATE) OF BUILDING MATERIALS AS REQUIRED FOR INSTALLATION OF A COMPLETE WORKABLE SYSTEM. 23. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. 24. PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL EXISTING SANITARY, STORM AND WATER SUPPLY ON THE SITE PRIOR TO THE PERFORMANCE OF ANY WORK. 25. PLUMBER SHALL PROVIDE SERVICE VALVES AT ALL BRANCH SUPPLY PIPING. SUCH SERVICE VALVES SHALL BE LOCATED ACCESSIBLY ABOVE THE CEILING. 26. PLUMBER SHALL BEFORE PLACING WATER SYSTEM IN OPERATION, CHLORINATE ENTIRE SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY PLUMBING CODES SUPPLY CERTIFICATE OF COMPLIANCE. 27. ALL NEW SANITARY PIPING SHALL BE GIVEN A FULL STATIC PRESSURE TEST. METHOD OF TEST AND REQUIREMENTS TO BE MET SHALL BE AS PER THE CITY. 28. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE PUMPING AND DRAINING OF TRENCHES OR PITS NECESSARY FOR THE INSTALLATION OF HIS WORK. 29. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 30. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE CITY AUTHORITIES AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 31. CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. 32. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. 33. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. 34. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE-BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 35. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 36. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. 37.GUARANTEE CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE OTHER THAN ORDINARY WEAR AND TEAR. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. 38. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE COMPLETED. 39. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS, PRIOR COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACT0R. 40. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 41.SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM COMPLETE UTILITY MOTOR WIRING SYSTEMS (EXCEPT AS NOTED) COMPLETE LIGHTING FIXTURE INSTALLATION COMPLETE TELEPHONE CONDUIT SYSTEM. CONDUIT FROM POINT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER PROVISIONS FOR FIRE ALARM/SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORD'S SYSTEM TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATED OF PROJECT CLOSE-OUT 42.ELECTRICAL SERVICE PROVIDE ELECTRICAL AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF METERING. 43. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. PROVIDE INTERIOR TYPE 4-D PLYWOOD O SERVE AS TELEPHONE TERMINAL BOARD - VERIFY EXACT LOCATION WITH JIMMY JOHN'S. 44. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 44.1 THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 44.2 MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. 44.3 EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND THE CITY CODES. 45. CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY OWNER'S REPRESENTATIVE. 46. RACEWAYS SHALL BE SURFACE METAL TYPE OF THE SIZE AND CHANNEL REQUIRED FOR SERVICE, CONSTRUCTED OF GALVANIZED STEEL WITH SNAP-ON COVERS, WITH 1/8" MOUNTING SCREW KNOCKOUTS IN BASE APPROXIMATELY 8" O.C. PROVIDE FITTINGS INDICATED WHICH MATCH AND MATE WITH RACEWAY. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING SUITABLE FOR PAINTING. 47. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 47.1 #10 AND SMALLER - SOLID WITH SINGLE BRAID OR STRANDED # 8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 47.2 ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 47.3 GENERAL WIRING SHALL HAVE THW, THHN OR THWN INSULATION. 47.4 ALUMINUM CONDUCTORS ARE NOT PERMITTED FOR BRANCH CIRCUIT WIRING. 47.5 WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS 48. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, KNOCK-OUT TYPE W/FIXTURE STUDS AS REQ. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. 49.WIRING DEVICES WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120/277V, WITH SCREW TERMINALS: MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2-POLE, 3-WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-20R UNLESS OTHERWISE INDICATED. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED-THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL-RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID-STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND-FAULT TRIP LEVEL; IN NEMA 5-15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2-POLE, 4-WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG-5362. ANY RECEPTACLE THAT IS INSTALLED AT OR BELOW 37 INCHES SHALL BE INSTALLED GROUND UP AND ANY RECEPTACLE THAT IS INSTALLED AT OR ABOVE 38 INCHES SHALL BE INSTALLED GROUND DOWN. 50. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL THE REQUIRED CITY CODES, NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CITY CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250, TABLE 250-66 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO GROUND WIRE FROM DAMAGE TO AN AREA 6 FT. ABOVE FLOOR. PROTECT MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LINE. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON-METALLIC CONDUIT. 51. LIGHTING PANEL BOARD SHALL BE 3-PHASE, 4-WIRE DISTRIBUTED PHASE TYPE WITH SOLID NEUTRAL GROUND LUG, GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOWN ON THE PANEL SCHEDULE. BUSWAYS SHALL BE HARD DRAWN COPPER. CABINET SHALL BE CONSTRUCTED OF CODE GAUGE STEEL WITH HINGED DOOR HAVING DIRECTORY CARD, NEATLY AND PROPERLY INSCRIBED AND SET IN FRAME WITH TRANSPARENT COVER. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. PANELBOARDS AND BREAKERS SHALL BE AS MANUFACTURED BY SQUARE-D OR EQUAL. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. 52. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON-FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY THE CITY. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE-D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FURNISH AND INSTALL DUAL ELEMENT CURRENT LIMITING FUSES OF TYPE AND AMPACITY DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE SHORT CIRCUIT FAULT CURRENT. 53. IF REQUIRED: PROVIDE DRY-TYPE TRANSFORMER WHICH SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWING AS MANUFACTURED BY SQUARE-D. TRANSFORMER SHALL HAVE A MINIMUM OF CLASS 155 INSULATION SYSTEM, AND A MINIMUM OF (4) 2-1/2 % TAPS BELOW AND (2) 2-1/2 % TAPS ABOVE RATED PRIMARY VOLTAGE. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. 54.LIGHTING FIXTURES THE CONTRACTOR SHALL PROVIDE A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. 55. PAINTING OF ELECTRICAL CONDUITS, ETC. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 56. RECEPTACLES, SWITCHES, AND COVER PLATES IN CUSTOMER AREAS ARE TO MATCH THE SURROUNDING WALL COLOR. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS ARE TO BE WHITE. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 57. FINALLY IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. 58. NO ROMEX OR BX WILL BE PERMITTED. 59. ALL WIRE SHALL BE INSTALLED IN THIN WALL (E.M.T.) CONDUIT UNLESS OTHERWISE NOTED. MINIMUM SIZE SHALL BE 3/4" EXCEPT FOR DROPS FOR DEVICES, SWITCH LEGS, TEMPERATURE CONTROL CONDUITS, WHERE INDICATED OR AS CALLED FOR ON DRAWINGS. 60. ALL THIN WALL FITTINGS SHALL BE OF THE STEEL COMPRESSION GLAND TYPE. 61. ALL UNDER FLOOR, UNDERGROUND OR EXPOSED-TO-WEATHER CONDUIT SHALL BE HEAVY WALL GALVANIZED RIGID STEEL. (G.R.S.), MINIMUM 3/4". 62. ALL CONDUITS 2" OR LARGER SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT (I.M.C.). 63. ELECTRICAL CONTRACTOR SHALL INSTALL SIZE OF CONDUIT SHOWN AND AS SCHEDULED ABOVE AND SHALL NOT REDUCE SIZING OF CONDUITS TO SUIT WIRE FILL CAPACITY. 64. ALL CONDUIT FASTENERS, STRAPS, SUPPORTS ETC. MUST BE "BOLT-ON" GALVANIZED STEEL ON EXPOSED CONSTRUCTION AND IN WET AREAS. ABOVE SUSPENDED CEILINGS WILL BE PERMITTED. ALL FASTENERS, SNAP-ON BLACK METAL "CADDY" CLIPS IN METAL PARTITION WALLS AND STRAPS, CLIPS, ETC. SHALL BE UL LISTED FOR THEIR USE. 65. NO CONDUITS SHALL BE ROUTED THROUGH HVAC AIR DUCTS. 66. ALL CONDUIT RACEWAYS SHALL BE CONCEALED IN OR WITHIN: WALLS, CEILING CAVITY, ROOF CONSTRUCTION (WHERE APPROVED), SLAB, GRADE, ETC. UNLESS OTHERWISE NOTED. ANY RACEWAY THAT IS TO BE ROUTED EXPOSED SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. ALL CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS WITH 90° F BENDS WHERE REQUIRED AND SHALL BE RACKED. PULL AND JUNCTION BOXES SHALL BE HELD TO A MINIMUM. 67. NO WIREWAY, THROUGH OR JUNCTION SHALL BE UTILIZED WHERE MORE THAN 8 CONDUITS ARE ENTERING OR LEAVING. MULTIPLE WIREWAYS, TROUGHS OR JUNCTIONS SHALL BE UTILIZED. IN NO CASE SHALL FEED OR CONDUIT OR CABLING BE MIXED WITH BRANCH CONDUIT. 68. NO CONDUITS SHALL BE ROUTED ON ROOF. ELECTRICAL CONTRACTOR SHALL COORDINATE ROOF PENETRATIONS WITH MECHANICAL PIPE CURBS. WHERE CONDUIT MUST BE RUN ON ROOF, IT SHALL BE RACKED WITH OTHER TRADES WHERE POSSIBLE OR PROVIDED WITH ITS OWN ROOF RACK SUPPORT SYSTEM WITH PROPER ROOF PLATE SO AS NOT TO CAUSE DAMAGE TO ROOF COVERING. 69. ELECTRICAL CONTRACTOR SHALL FIREPROOF ALL CONDUIT OPENINGS BETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION BLOCK WALLS WITH AN ENGINEER APPROVED UL LISTED FIRE RETARDANT MATERIAL. 70. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. ELECTRICAL CONTRACTOR SHALL WEATHERPROOF ALL PENETRATIONS THRU FOUNDATION AND EXTERIOR WALLS. 71. FINAL EQUIPMENT CONNECTION TO PILOT CONTROL DEVICES SHALL BE MADE WITH 1'-0" MINIMUM LENGTH OF FLEXIBLE CONDUIT CONNECTION (IE. SOLENOID VALVES, MOTORIZED DAMPERS, ETC.). 72. ELECTRICAL CONTRACTOR SHALL PROVIDE LOCAL LOW VOLTAGE SWITCHING IN LIEU OF LINE VOLTAGE SWITCHING FOR 277 CIRCUITS IF REQUIRED BY LOCAL CODE. ELECTRICAL CONTRACTOR SHALL PROVIDE BARRIERS TO SEPARATE DIFFERENT PHASES IN 277 VOLT GANGED SWITCH BOXES. M E C H A N I C A L , E L E C T R I C A L , P L U M B I N G G E N E R A L N O T E S Reviewed by SAFEbuilt 12/12/2019 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 MEP-2 SPECIFICATIONS MECH./ELEC./PLUMB. DUPLEX RECEPTACLE, 208V, 20 AMP RATED 18" A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. DESCRIPTIONSYMBOL J J SYMBOL DESCRIPTIONMATERIALS: 1. ALL MATERIALS SHALL BE NEW, OF FIRST QUALITY AND UL LISTED FOR THE SPECIFIC DESIGN PURPOSE. 2. SANITARY, VENT AND STORM LINES SHALL BE CAST IRON AND AS PERMITTED BY THE CITY AUTHORITIES. PVC NOT PERMITTED WHERE DISCHARGE EXCEEDS 90°F 3. ALL WATER AND WASTE PIPING TO BE RUN ON WARM SIDE OF INSULATION. 4. DOMESTIC SUPPLY PIPING LOCATED ABOVE THE FINISHED FLOOR SHALL BE TYPE "L" COPPER. UNDERGROUND DOMESTIC SUPPLY PIPING SHALL BE TYPE "K" COPPER. 5. THREADED FITTINGS ON GALVANIZED STEEL PIPING SHALL BE 150# CLASS GALVANIZED MALLEABLE IRON FITTING CONFORMING TO ASTM A-197 SPECIFICATION. 6. FURNISH AND INSTALL UNIONS WHERE INDICATED OR NECESSARY FOR REPAIR OR SERVICE. UNIONS 2" AND SMALLER SHALL BE STANDARD GROUND JOINT BRASS TO IRON SEAT, MALLEABLE IRON, SCREWED. UNIONS 2-1/2" AND LARGER SHALL BE STANDARD CAST IRON FLANGED UNIONS 125# CLASS. 7. VALVES SHALL BE MANUFACTURED BY CRANE, STOCKHAM. 8. DOMESTIC HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH ONE OF THE FOLLOWING: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1" THICK PREFORMED FIBERGLASS WITH "K" FACTOR OF 0.23 MAXIMUM AT 75°F. MEAN TEMPERATURE. JACKET TO BE FACTORY APPLIED KRAFT PAPER WITH VAPOR BARRIER. B. 1" THICK MOLDED RIGID PHENOLIC FOAM WITH "K" FACTOR OF 0.23 MAXIMUM AT 78°F MEAN TEMPERATURE WITH FACTORY APPLIED LAMINATED ALUMINUM FOIL AND WHITE KRAFT PAPER VAPOR BARRIER JACKET. 9. DOMESTIC COLD WATER PIPING AND SUSPENDED HORIZONTAL STORM SEWERS AND ALL FITTINGS SHALL BE INSULATED WITH: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1/2" THICK INSULATION W/ FRK WRAP FOR PIPING UP TO 1-1/4" DIAMETER. B. 1" THICK AT STORM C. SEAL BUTT & LONGITUDIAL JOINTS W/ WATERPROOF SEALANT. 10. PIPE INSULATION AT ALL PIPE HANGERS SHALL CONSIST OF INSUL-SHIELD FIBERGLASS PIPE SUPPORTS AS MANUFACTURED BY INSUL-COUSTIC OR ARCHITECT/ENGINEER APPROVED EQUAL. 11. HANGERS SHALL BE OF STANDARD WEIGHT STEEL OR IRON ROD AND RING OR CLEVIS TYPE. PROCEDURES: 1. ALL SUSPENDED HORIZONTAL PIPING SHALL BE SUPPORTED BY HANGERS SPACED NO FURTHER THAN 8' - 0" APART (4' -0" APART FOR PVC PIPING). NO PIPING SHALL BE SELF-SUPPORTING NOR BE SUPPORTED FROM EQUIPMENT CONNECTIONS AND PER U.P.C. TABLE 3-2. 2. ALL PARALLEL PIPES [TWO (2) OR MORE] SHALL BE SUPPORTED ON A CHANNEL TYPE TRAPEZE HANGER. 3. SUPPORTS AND HANGERS SHALL BE INSTALLED TO PERMIT FREE EXPANSION AND CONTRACTION IN PIPING SYSTEMS UNLESS PIPE REQUIRES FIRM ANCHOR CONTROL. 4. HORIZONTAL SOIL OR WASTE LINES SHALL BE AT A SLOPE OF NOT LESS THAN AS NOTED IN NOTE #(17) BELOW AND SHALL BE HELD CLOSE TO THE CONSTRUCTION TO MAINTAIN A MAXIMUM OF HEAD ROOM. ALL CHANGES OF DIRECTION AND JUNCTIONS SHALL BE MADE WITH "Y" FITTINGS AND 1/8" BENDS. NO LINES OF ANY KIND SHALL BE LOCATED BELOW FREEZERS. ALL DRAIN LINES SHALL BE PROTECTED FROM FREEZING. 5. HOT AND COLD WATER PIPING SHALL BE PROPERLY PITCHED TO LOW POINTS IN THE SYSTEM WHERE DRAINS SHALL BE INSTALLED. 6. CLEANOUTS SHALL BE PLACED AT ALL DEAD ENDS, AT CHANGES OF DIRECTION, AT 50'-0" INTERVALS ON HORIZONTAL RUNS, OUT OF HIGH TRAFFIC AREAS, (NOT UNDER CASES) ETC. WHERE CLEANOUTS OCCUR IN CONCEALED SPACES, THEY SHALL BE PROVIDED WITH EXTENSIONS TO FLOOR ABOVE OR TO WALLS. A HAND-HOLE TEST TEE SHALL BE PLACED AT THE BASE OF EACH STACK. 7. VENT STACKS EXTENDING UP THROUGH THE ROOF SHALL BE FLASHED WITH SIX POUND SHEET LEAD. FLASHING SHALL EXTEND 12" IN ALL DIRECTIONS FROM THE VENT, CARRIED OVER AND TURNED DOWN THE INSIDE OF THE VENT. ALL SEAMS AND JOINTS OF FLASHING SHALL BE SOLDERED AND PROVEN WEATHERTIGHT. EXTEND VENTS A MIN. OF 12" ABOVE ROOF, AND 30" AWAY FROM PARAPET. 8. ALL SUPPLY PIPING TO BE RUN OVERHEAD, UNLESS NOTED OTHERWISE. 9. ALL SUPPLY PIPING TO BE A MINIMUM OF 1/2" DIA. 10. EACH FIXTURE WILL HAVE A 3/4" X 12" AIR CHAMBER. 11. PROVIDE SERVICE VALVE AT BRANCHES AND AT ALL APPLIANCES. 12. ALL FIXTURES WILL BE FURNISHED WITH INTEGRAL STOPS. 13. BURIED SANITARY AND WASTE LINES WILL BE AS NOTED ON PLUMBING PLAN.. 14. ALL FLOOR DRAINS AND FIXTURES TO BE VENTED IN ACCORDANCE WITH LOCAL CODES. 15. ALL HORIZONTAL VENT PIPING SHALL BE RUN ABOVE FINISHED CEILINGS AND SLOPED UP TOWARD MAIN STACK. 16. THE PLUMBING CONTRACTOR WILL NOT INSTALL COMBUSTIBLE PIPING MATERIAL IN OR THROUGH FIRE RATED ASSEMBLIES. 17. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" DIA. AND UNDER. 18. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THEN 1/4" PER FOOT FOR PIPING 4" DIA. AND OVER. 19. ALL EQUIPMENT DEVICES SHALL BE INSTALLED WITH UNIONS IN SUCH A MANNER TO FACILITATE EASY REMOVAL AND MAINTENANCE OF EQUIPMENT WITHOUT DISRUPTING SERVICE AND CAUSING MAJOR PIPING REVISIONS. 20. ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS OR COUPLINGS. 21. JOINTS IN COPPER TIUBING SHALL BE MADE BY THE APPROPRIATE USE OF APPROVED COPPER OR COPPER ALLOYFITTINGS. SURFACES TO BE JOINED BY SOLDERING SHALL BE CLEANED BRIGHT BY MANUAL OR MECHANICAL MEANS. THE JOINTS SHALL BE PROPERLY FLUXED WITH AN APPROVED TYPE-FLUXAND MADE UP WITH APPROVED SOLDE. SOLDER AND FLUXES SHALL BE MANUFACTURED TO APPROVED STANDARDS. SOLDER AND FLUXES WITH A LEAD CONTENT THAT EXCEEDS TWO-TENTHS (.20) OF 1 PERCENT SHALL BE PROHIBITED IN PIPING SYSTEMS USED TO CONVET POTABLE WATER. NOTE: 1. RECEPTACLES, SWITCHES, AND COVER PLATES IN DINING ROOM ARE TO MATCH THE SURROUNDING WALL FINISHES. 2. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS NEED TO BE WHITE. 3. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 4. ON ALL CONDUIT RUNS: A. ARROW INDICATE HOME RUN TO PANEL. B. SLASHES INDICATE QUANTITY OF WIRES. 1. SHORT SLASHES INDICATE PHASE AND SWITCH LEGS. 2. LONG SLASHES INDICATE NEUTRAL CONDUCTORS. 3. LONG SLASHES WITH DOT INDICATE GREEN GROUND CONDUCTORS. 5. DOTTED SYMBOL ON PLAN INDICATES EXISTING FIXTURE, DEVICE OR EQUIPMENT. REFER TO DEMOLITION NOTES AND SYMBOLS FOR FIXTURE INFORMATION. GROUND INDICATES GREEN GROUND CONDUCTOR CONNECTED TO EQUIPMENT AND PANEL GROUND FAULT INTERRUPTER FURNISHED AND INSTALLED FURNISHED BY OTHERS INDICATES FIXTURE CONNECTED TO EMERGENCY SERVICE ELECTRICAL CONTRACTOR ABOVE FINISHED FLOORA.F.F. E.C. EM F.B.O. F & I GFI GRND NL WP NIGHT LIGHT, 24 HOUR OPERATION SINGLE GANG OUTLET, STUB EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE FOR CRT CABLES. CABLES F.B.O. UNLESS NOTED OTHERWISE. MECHANICAL EQUIPMENT TAG-SEE MECHANICAL EQUIPMENT SCHEDULE NON-FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWING FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWINGS ELECTRICAL PANEL MOTOR CONNECTION SINGLE GANG TELEPHONE OUTLET, STUB "EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE JUNCTION BOX WALL MOUNTED JUNCTION BOX CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE, 120V, 20 AMP RATED 18" A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. DUPLEX RECEPTACLE, 120 VOLT, 20 AMPERE RATED. UNLESS NOTED OTHERWISE. HUBBELL OR LEVITON #5362-I. SUBSCRIPT: "GFI" - DENOTES GROUND FAULT INTERRUPTER TYPE RECEPTACLE "IG" - DENOTES ISOLATED GROUND TYPE RECEPTACLE HUBBELL OR LEVITON #IG-5362 INDICATES "GREEN" GROUND CONDUCTOR, SIZED AS NOTED ON DRAWINGS CONDUIT RUN ROUTED CONCEALED IN/BELOW CONCRETE SLAB OR BELOW GRADE. CONDUIT RUN ROUTED CONCEALED IN WALLS OR ABOVE CEILING IN FINISHED AREAS. CONDUIT EXPOSED IN UNFINISHED AREAS THERMAL OVERLOAD TOGGLE SWITCH WITH PROPERLY SIZED HEATER ELEMENTS, 48" A.F.F. UNLESS EQUIPMENT MOUNTED SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED OTHERWISE. SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH CONTROL "3" - DENOTES THREE WAY TOGGLE SWITCH "2P" - DENOTES TWO POLE TOGGLE SWITCH "P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LIGHT IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING "4" - DENOTES FOUR WAY TOGGLE SWITCH WEATHERPROOF RETURN DUCT UP THRU FLOOR/ ROOF MANUAL VOLUME DAMPER THERMOSTAT EQUIPMENT TAG GAS PIPING GAS COCK REDUCER SUPPLY DUCT UP THRU FLOOR/ ROOF UNDERCUT DOOR ROOFTOP UNIT OUTSIDE AIR INTAKE NECK MANUAL VOLUME DAMPER GRILLE FURNISHED BY OTHERS EXTERNAL STATIC PRESSURE EXHAUST FAN EACH DIFFUSER CUBIC FEET OF AIR PER MINUTECFM DIFF EA EF-# ESP FBO GR MVD NK OAI RTU-# U-CUT 1. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS TO VERIFY THE EXTENT OF THE DEMOLITION AND REMODELING WORK. ELECTRICAL CONTRACTOR SHALL SURVEY EXISTING SITE AND DETERMINE EXTENT OF NECESSARY REALLOCATIONS. REMOVALS AND REPAIRS TO EXISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM CITY AND STATE CODE REQUIREMENTS. ALL ELECTRICAL OUTLETS, FIXTURES RECEPTACLES, DEVICES, ETC. NOT BEING REUSED SHALL BE REMOVED AND OUTLETS ARE TO BE CAPPED ACCORDING TO NOTE #7: CONDUIT TO BE ABANDONED IN PLACE: AND ALL WIRING SHALL BE DISCONNECTED AT SOURCE AND REMOVED COMPLETELY. NO EXISTING JUNCTIONS OR CONDUIT COVERS SHALL BE BURIED IN NEW WALLS. ELECTRICAL CONTRACTOR TO RELOCATE SAME AS REQUIRED. A FIELD SURVEY VERIFICATION IS MANDATORY IN ORDER TO SUBMIT AN ELECTRICAL BID, FAILURE TO DO SO SHALL NOT RELIEVE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTRACT. 2. EXISTING CONDUIT CAN BE REUSED PROVIDING IT IS CHECKED FOR CONTINUITY OF GROUND, BLOWN FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 3. ALL CUTTING AND PATCHING OF EXISTING PLASTER, DRYWALL, WOOD, CONCRETE ETC., FOR THE ELECTRICAL INSTALLATION IS BY THE ELECTRICAL CONTRACTOR. BEFORE ANY CUTTING, APPROVAL FROM THE ARCHITECT IS NECESSARY. CARE IS TO BE TAKEN AND ALL CUTS OR CORING ARE TO BE SQUARE - NO CHOPPING! 4. ALL EXISTING EQUIPMENT IS TO REMAIN OPERATIONAL DURING THE CONSTRUCTION PERIOD. ANY TEMPORARY WIRING OR REROUTING OF CIRCUITRY TO ACHIEVE THIS IS BY THE ELECTRICAL CONTRACTOR. SHUTDOWN OF EXISTING SERVICES SHALL ONLY BE PERMITTED UPON WRITTEN APPROVAL FROM THE OWNER AND THEN ONLY FOR THE DATE AND DURATION AGREED UPON. INCLUDE ALL PREMIUM TIME CHARGES IN THE BASE BID. 5. UNLESS INDICATED OTHERWISE, ALL LIGHTING FIXTURES, ELECTRICAL DEVICES AND ALL ITEMS OF THE EXISTING HVAC SYSTEM SHALL REMAIN UNLESS IN CONFLICT WITH REMODELING. 6. ALL LIGHTING FIXTURES REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE OWNER. IF THE OWNER ELECTS NOT TO RETAIN FIXTURES, ELECTRICAL CONTRACTOR SHALL REMOVE FIXTURES FROM JOB SITE AND DISPOSE OF PROPERLY. 7. ELECTRICAL CONTRACTOR SHALL BLANK WITH PROPER FINISH PLATE IF FLUSH OUTLET EXISTS FOR ITEMS TO BE REMOVED. ANY INTERRUPTION OF CIRCUITING TO AREAS NOT BEING REMODELED SHALL BE INTERCEPTED AT A LOCATION THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION. HOMERUN CIRCUITING FOR THESE INTERRUPTED CIRCUITS IS TO BE NEW WIRING. AFTER REMOVAL, ALL CONTINUITY IS TO BE CHECKED FOR ALL OUTLETS IN THE AREAS NOT BEING REMODELED TO INSURE PROPER FUNCTIONING. 8. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT (FOR EXAMPLE: LIGHTING FIXTURES, RECEPTACLES, DEVICES, CONDUIT AND WIRING) THAT WILL BE ABANDONED OR IN CONFLICT WITH NEW CONSTRUCTION. NO ADDITIONAL COST WILL BE PERMITTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF REMODELING. 9. ALL CONDUIT, DEVICES, FIXTURES, ETC. SHOWN IN THE DEMOLITION DRAWINGS TO BE REMOVED OR RELOCATED ARE ONLY FOR THE CONVENIENCE OF THE BIDDERS. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL ITEMS PRIOR TO SUBMITTING A BID. 10. NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE. EACH CONTRACTOR SHALL ADJUST HIS WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES, CONDUITS AND BEAM NOT SHOWN ON PLANS. EACH CONTRACTOR SHALL ADAPT HIS WORK TO MEET ALL ACTUAL CONDITIONS ON THE EXISTING PREMISES. 1. ALL EQUIPMENT/DEVICES SHALL BE NEW AND OF FIRST RATE QUALITY (UNLESS OTHERWISE SPECIFIED) AND IS TO BEAR THE APPROPRIATE AGA, CSA OR UL APPROVED LABELS, LISTINGS, AND CERTIFICATIONS FOR THE SPECIFIC DESIGN PURPOSE. 2. ALL EQUIPMENT SOUND LEVELS SHALL NOT EXCEED 50 DB AT PROPERTY LINE. 3. ALL INTERCONNECTING WIRING AT UNIT SHALL BE FACTORY PREWIRED AND REQUIRE ONLY ONE (1) POWER CONNECTION TO THE UNIT BY THE ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL FURNISH COMBINATION MAGNETIC STARTER-DISCONNECT SWITCHES AS REQUIRED (WEATHERPROOF FOR EQUIPMENT LOCATED OUTSIDE OF BUILDING). THE ELECTRICAL CONTRACTOR WILL INSTALL. 5. SUBMIT EIGHT (8) COPIES OF EACH CATALOG CUT, FOR THE EQUIPMENT SPECIFIED, TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUCTION. THIS CONTRACTOR SHALL ALSO ASSEMBLE PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED AND BIND TOGETHER WITH EQUIPMENT CUTS AND CONTROL WIRING DIAGRAMS. SUBMIT EIGHT (8) COPIES TO THE OWNER/ARCHITECT/ENGINEER. 6. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL NEW STRUCTURAL STEEL MEMBERS, SLEEVES, AND SHIMS REQUIRED TO LEVEL AND SUPPORT EQUIPMENT, ROOF CURBS AND EQUIPMENT SUPPORTS. DUCTWORK: 1. ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED METAL IN ACCORDANCE WITH SMACNA STANDARDS FOR LOW AND MEDIUM PRESSURE DUCT CONSTRUCTION, DUCT SIZES SHOWN INDICATE INSIDE DIMENSIONS. 2. ALL DUCTWORK ACCESS DOORS SHALL BE OF SUFFICIENT SIZE TO PERMIT EASY ACCESS AND THE SERVICING OF DAMPERS, CONTROLS, DEVICES, ETC. ACCESS DOORS SHALL BE VENTLOK COMPLETE WITH #50 HINGES WITH BRASS PINS, #100 LATCHES, DOOR GASKETS, ETC. DOORS LOCATED IN INSULATED DUCTWORK SHALL HAVE 1/2" THICK FIBERGLASS INSULATION BETWEEN TWO THICKNESS OF SHEET METAL. 3. DUCTWORK SHALL COMPLY WITH ALL REGULATIONS REGARDING FIRE STOPPING, PROOFING AND DAMPERING. ACCESS DOORS OF SUFFICIENT SIZE FOR EASY ACCESS AND SERVICING SHALL BE PROVIDED AT ALL FIRE DAMPERS. 4. AIR VELOCITY IN LOW PRESSURE MAIN SUPPLY TRUNKS SHALL NOT EXCEED 1500 FPM, IN SUPPLY BRANCHES VELOCITY SHALL NOT EXCEED 1200 FPM, AND IN RETURN AIR DUCT VELOCITY SHALL NOT EXCEED 1200 FPM. DUCT INSULATION: 1. ALL SUPPLY DUCTWORK FROM HEATING/COOLING UNITS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 2. ALL RETURN DUCTWORK WITHIN 10'-0" OF HEATING/COOLING UNITS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 3. ALL EXHAUST DUCTWORK ON THE SUCTION SIDE OF EXHAUST FANS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER, FOR A MINIMUM DISTANCE OF 10'-0". 4. ALL DUCT INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED RATING OF NOT MORE THAN 50. 5. EXPOSED SPIRAL DUCT SHALL BE UN-INSULATED. PROVIDE INSULATION ONLY IF REQUIRED BY GOVERNING AGENCIES. DUCT SMOKE DETECTOR : 1. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AND RETURN DUCTS ON ALL A/C EQUIPMENT 2000 CFM OR LARGER. ELECTRICAL CONTRACTOR TO SUPPLY AND WIRE DETECTOR. MECHANICAL CONTRACTOR TO DUCT MOUNT DETECTOR. ELECTRICAL AND MECHANICAL CONTRACTORS TO COORDINATE SIZES AND TYPES FOR INSTALLATION. GAS PIPING: (IF APPLICABLE) 1. THIS CONTRACTOR SHALL CONTACT LOCAL GAS COMPANY TO COORDINATE: NEW GAS LOAD EXISTING, METER LOCATION, AND PRESSURE REGULATOR ASSEMBLY. 2. GAS PIPING SHALL BE SCHED. 40 BLACK CARBON STEEL, WITH MALLEABLE IRON 150 LB. FITTINGS. GAS PIPING LARGER THAN 2" SHALL BE WELDED, PIPING UNDER 2" SHALL BE THREADED CONNECTIONS - PAINT TO MATCH. 3. GAS COCKS (CRANE #254 WITH CHECK OR EQUAL), AND DIRT LEGS (MIN. 6") SHALL BE INSTALLED IN THE PIPING TO EACH PIECE OF GAS FIRED EQUIPMENT. 4. BEFORE FINAL EQUIPMENT CONNECTIONS ARE MADE, PNEUMATICALLY TEST GAS PIPING AT 15 PSIG AIR PRESSURE. THE PRESSURE TEST SHALL BE DEEMED ACCEPTABLE IF THE PIPING SYSTEM HOLDS THE PRESSURE FOR FOUR (4) HOURS. TESTING SHALL BE WITNESSED BY OWNER. E L E C T R I C A L S Y M B O L S L I S TP L U M B I N G M A T E R I A L & P R O C E D U R E N O T E S M E C H A N I C A L S Y M B O L S L I S TM E C H A N I C A L E Q U I P M E N T N O T E S E L E C T R I C A L S Y M B O L S N O T E S M E C H A N I C A L M A T E R I A L A N D P R O C E D U R E N O T E S E L E C T R I C A L D E M O L I T I O N N O T E S Reviewed by SAFEbuilt 12/12/2019 PLUMBING:ELECTRICAL: SHEET A-4 ADD NOTE STATING: KOLPAK DUO-PACK WALK-IN FREEZER/COOLER WITH REMOTE MOUNTED COMPRESSORS UNIT. COMPRESSOR SHALL BE MOUNTED ON THE ROOF ON ONE BASE. CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH JIMMY JOHN'S EQUIPMENT SUPPLIER. 35/2 FREEZER 3270 3270 20/1 COOLER 1286 ALTERNATE FREEZER/COOLER POWER PLAN 1/2" = 1'-0"C ALTERNATE MECHANICAL CONNECTIONS FOR THE REMOTE SPLIT SYSTEM COMPRESSOR FOR THE WALK-IN COOLERS CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECT MOUNTED. CONTACT JUSTIN CHAPMAN WITH KEC DESIGN AT 217-356-1640. ARCHITECTURAL: SHEET E-1 DISCONNECT SWITCH FOR SINGLE POINT CONNECTION TO CONDENSING UNIT. FUSE PER UNIT NAME PLATE. CONTRACTOR TO INSTALL CONTROL WIRING BETWEEN THE EVAPORATOR UNIT AND CONDENSING UNIT AND INSTALL DRAINLINE HEAT TAPE PER MANUFACTURERS RECOMMENDATIONS. SHEET E-3 2 1 ALTERNATE FREEZER/COOLER PLUMBING PLAN 1/2" = 1'-0"B 1 MECHANICAL: SHEET M-1 NEW ROOF MOUNTED REMOTE CONDENSING UNIT PROVIDED BY OWNER, INSTALLED BY REFRIGERATION CONTRACTOR. ROUTE LIQUID/SUCTION REFRIGERANT LINES THRU ROOF TO COOLER/FREEZER EVAPORATORS. ALTERNATE FREEZER/COOLER MECHANICAL PLAN 1/2" = 1'-0"A 1 SHEET P-1 CONDENSATE LINES MUST STUB OUT DIRECTLY FROM WALKINS 20" BELOW CEILING OF WALK-INS, CENTERED ON BACK PANEL OF EACH BOX. MUST NEVER HAVE EXPOSED LINES ON INSIDE OF WALK-INS. ROUTE 1" CONDENSATE LINES FROM COOLER/FREEZER EVAPORATORS IN CAVITY/FURR WALL AS SHOWN. MUST RUN 1'-0" PER 1/2" DROP. MUST STUB OUT AT 12" ABOVE FLOOR DRAIN AND TERMINATE WITH AIR GAP. HEAT TRACE CONDENSATE LINE INSIDE FREEZER. WRAP ARMAFLEX AROUND THE CONDENSATE LINES IN THE WALK-IN FREEZER AND INSULATE LINES IN THE COOLER. 2 T J A-19 WP A-9,11 A-13 WALK-IN FREEZER EVAP./ KOLPAK DUO-PAK UNIT WALK-IN COOLER EVAPORATOR 10.72A 35A/2P DISCONNECT 2P, 35A23 23A 20A/1P DISCONNECT -VERIFY 1P, 20A INTERLOCK WITH FREEZER EVAPORATOR120V/1 Ø 208V/1 Ø 3 #8, 1 #10 GRD., 1" C.ON ROOF POWER FOR FREEZER / DUO-PACK LOCATED ON ROOF AT DUO-PACK 2 #12, 1 #12 GRD., 3/4"C. E Q U I P M E N T P O W E R S C H E D U L E X F I X T U R E A N D E Q U I P M E N T S C H E D U L E 1 1 5' x 6' x 7'-6" TALL WALK-IN FREEZER 8' x 6' x 7'-6" TALL WALK-IN COOLER 23 23A KOLPAK DUO-PAK 208V-1P-WIRE TO J-BOX 120V-1P-1WIRE TO J-BOXKOLPAK DUO-PAK 1 23A 23 FD 2 SQ J P A-17 1 23A 23 1 23A 23J P A-17 1 RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 MEP-3 SPECIFICATIONS ALT. WALK-INS Reviewed by SAFEbuilt 12/12/2019 FIRE SPRINKLER ROOM 102 BACKROOM 100 DINING 101 PREP A-3,5 +72" 17 A-25 +12" 22 A-36 +72" A-34 +81" 16D 6 23A 4 A-18I.G. GFI 1 8 A-32 A-30 49 WH 1 A-20 A-20 A-20 23 A-13,15 11 104 WOMEN 13 12 B-5 +108" A-9,11 T B-13 2 #12, 3/4"C B-11 2 #12, 3/4"C 5 WP JJ MOUNT IN CABINET A-29 +60"15A 1413 3A A-33 +12" 16 J J P 13 A-27 +12" A-3129 A-26 3 A-1 I.G. GFI A-1 I.G. GFI A-26 A-28 10 103 MEN T A-17 8A B-9 +12" 9 B-7 B-3 3 A-2-k A-2-k 27 A-7 +44" A-2-k A-12-k 3 A-12-kA-2-k 3 A-12-k 3 A-12-k J P A-17 B-14,16,18 +84" J J 5 WP B-15 2 #12, 3/4"C B-17 2 #12, 3/4"C 15 B-1 2 #12, 1 #12 GRD., 3/4"C WP J 7RTU 1 B-2,4,6 E-1 POWER PLAN ELECTRICAL RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 NORTH ELECTRICAL POWER PLAN 1/4" = 1'-0"A GENERAL REQUIREMENTS A. E.C. SHALL COORDINATE FULLY WITH OTHER CONTRACTORS ASSOCIATED WITH THIS PROJECT TO VERIFY ALL EQUIPMENT LOCATIONS, CONNECTION REQUIREMENTS, ELEVATIONS AND LOCATIONS OF PIPES, CONDUITS AND DUCTS TO PREVENT CONFLICTS DURING CONSTRUCTION. ANY RELOCATION OR REROUTING OF EQUIPMENT, PIPES, CONDUITS, DUCTS OR MATERIALS RESULTING FROM A LACK OF COORDINATION BETWEEN CONTRACTORS WILL BE AT THE CONTRACTORS EXPENSE. B. EQUIPMENT ROUGH-INS SHOWN ARE ACCURATE TO THE BEST OF DESIGNER'S KNOWLEDGE. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN. THEREFORE,THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE E.C. TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR. C. E.C. SHALL FURNISH AND INSTALL ALL REQUIRED DISCONNECT SWITCHES AND MOTOR STARTERS TO ALL EQUIPMENT. D. E.C. SHALL REVIEW WITH OWNER AND SIGNAGE MANUFACTURER, REQUIREMENTS AND LOCATION OF BUILDING SIGNAGE PRIOR TO CONSTRUCTION AND PROVIDE 120VAC CONNECTION AS REQUIRED. E. E.C. SHALL PROVIDE AS-BUILT DRAWINGS AT JOB COMPLETION TO ARCHITECT. F. ALL WORK SHALL BE INSTALLED PER ALL GOVERNING CODES. G. SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS INCLUDING RESTROOM FIXTURES. BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. H. SUBCONTRACTOR IS TO SUPPLY AND INSTALL UNISTRUT AND 3/8" THREADED ROD TO HANG/SUPPORT LIGHTING. RACEWAY SYSTEMS A. ALL BRANCH CIRCUIT WIRING SHALL BE ROUTED IN EMT, RIGID OR ELECTRICAL METALLIC TUBING. USE STEEL SET SCREW TYPE FITTINGS ON ALL EMT. B. CONDUIT SHALL BE SUPPORTED AT INTERVALS PER NEC REQUIREMENTS AND SHALL BE SECURELY FASTENED TO BUILDING WITH AN APPROVED FASTENING SYSTEM. C. ALL NEW CONDUIT TO BE CONCEALED IN WALLS. PATCH/PAINT IF NECESSARY. WIRING, WIRING DEVICES, PLATES AND GROUNDING A. ALL WIRING SHALL CONSIST OF COPPER CONDUCTORS WITH THERMOPLASTIC INSULATION RATED FOR SIX HUNDRED (600) VOLTS. ALL WIRING INSULATION SHALL BE HEAT AND MOISTURE RESISTANT TYPES THW, THWN, OR THHN FOR INTERNAL AND DRIVE LOCATIONS. B. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG FOR ALL BRANCH CIRCUITS (I.E. RECEPTACLES, LIGHTING, EQUIPMENT POWER, ETC.). MINIMUM CONDUCTOR SIZE SHALL BE NO. 10 AWG FOR ALL FEEDER CIRCUITS TO MECHANICAL EQUIPMENT (I.E U-1, CONDENSERS, ETC.) C. ALL SPLICED OR CONNECTIONS SHALL BE MADE IN OUTLET BOXES, JUNCTION BOXES OR EQUIPMENT WHERE ACCESSIBLE. D. CONDUCTORS SHALL BE PULLED WITHOUT THE USE OF OIL OR GREASE. WIRE PULLING LUBRICANTS WHICH ARE APPROVED FOR USE WITH CONDUCTOR INSULATION MAY BE USED. CARE SHALL BE TAKEN IN PULLING WIRE TO ASSURE THAT MAXIMUM ALLOWABLE PULLING TENSION OF WIRE IS NOT EXCEEDED. WIRING WITH DAMAGED CONDUCTORS OR INSULATION WILL NOT BE ACCEPTED. E. ALL PLUG-IN DEVICES SHALL BE GROUNDED TYPE. A GROUNDING JUMPER FROM RECEPTACLE TO OUTLET BOX SHALL BE INSTALLED WHERE CONDUIT SYSTEM IS USED FOR GROUND. F. INSTALL INSULATED GREEN GROUNDING CONDUCTOR (NO. 12 AWG MINIMUM) IN RACEWAYS AS INDICATED ON DRAWINGS AND IN ALL NON-METALLIC RACEWAYS PER NEC. G. SWITCHES FOR LIGHTING CONTROL SHALL BE INDUSTRIAL GRADE. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS PLATES IN THE KITCHEN AND RESTROOMS. SIDE WIRED ONLY, TWENTY (20) AMP, ONE HUNDRED TWENTY/TWO HUNDRED SEVENTY-SEVEN (120/277) VOLT. H. DUPLEX RECEPTACLES SHALL BE INDUSTRIAL GRADE, THREE (3) WIRE GROUNDING, WHITE COLOR, FINDER GROOVE, TWENTY (20) AMP, NEMA 5-20R 125 VAC. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS STEEL PLATES IN THE KITCHEN AND RESTROOMS. I. PLATES SHALL BE FURNISHED AND INSTALLED FOR ALL WIRING DEVICES, TELEPHONE OUTLETS, JUNCTION BOXES, ETC. J. PLATES FOR FLUSH MOUNTED DEVICES SHALL MATCH THE SURROUNDING FINISH, EXCEPT IN THE KITCHEN/PREP AREA AND RESTROOMS WHERE THEY SHALL BE STAINLESS STEEL SURFACE MOUNTED BOXES SHALL BE GALVANIZED STEEL. K. E.C. SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM; REGARDLESS OF CIRCUITING INDICATED. L. ALL DUPLEX RECEPTACLES INSTALLED IN KITCHEN AND PREPERATION AREA ARE TO BE GFCI RATED, WHERE NOT PROTECTED BY A GFCI CIRCUIT BREAKER. M. THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISBILE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. G E N E R A L R E Q U I R E M E N T S G E N E R A L N O T E S MOUNT THE NETWORK CABINET (OR APPROVED EQUIVALENT) ON THE WALL BELOW AND TIGHT TO THE DROP CEILING NEAR DESK SHELVES - PROVIDE DUPLEX RECEPTACLE AND DSL LINE IN THE NETWORK CABINET, SEE COM1 FOR MORE INFORMATION. PROVIDE ONE (1) 3/4" CONDUIT STUBBED UP INTO ACCESIBLE CEILING. VERIFY LOCATION IN FIELD FOR ALL VOICE AND DATA LOCATIONS. SEE ELECTRICAL/DATA PHONE BANK DETAIL ON SHEET COM-1. FLUSH MOUNTED RECEPTACLE CENTERED ABOVE EVERY WINDOW AND DOOR TRANSOM FOR NEON SIGNS ,VERIFY LOCATION - FULLY RECESSED ON SOFFIT FACE 6" ABOVE STOREFRONT V.I.F. ELECTRICAL PANELS - FULLY RECESSED- PANEL DOORS TO BE FLUSH MOUNTED TO FINISHED SURFACE. STORE FRONT SIGN CONTROLLED BY TIME SWITCH LOCATED NEAR NETWORK CAB'T, TIGHT TO THE CEILING. ELECTRICAL CONTRACTOR TO VERIFY LOCATION OF SIGN JUNCTION BOX WITH SIGN CONTRACTOR AND ARCHITECT. PROGRAMMABLE THERMOSTAT WITH CLEAR LOCK BOX (AT 48" A.F.F. MAX.) - COORDINATE RECESSED "J" BOX WITH ALL FINISH WALL MATERIALS/DEVICES. ELECTRICAL CONTRACTOR TO FURNISH AND PROVIDE POWER FOR DUCT SMOKE DETECTOR. INSTALLED BY MECHANICAL CONTRACTOR. NOT USED. DRIVERS SHELF QUAD OUTLETS TO BE ORIENTED HORIZONTALLY- SEE 1/COM-1 FOR MOUNTING HEIGHTS AND LOCATIONS. DUPLEX OUTLET AT +63.5" TO ALIGN VERTICALLY WITH DATA OUTLET BELOW.SEE ELECTRICAL/DATA PHONE BANK DETAIL 1/COM-1. REFERENCE DETAIL 2/COM-1. COMMUNICATION PANEL (HME) FOR DRIVE THRU SERVICE TO BE MOUNTED ON WING WALL SEE 4/COM-1. DUPLEX OUTLET AT +63.5" TO ALIGN VERTICALLY WITH DATA OUTLET BELOW - SEE ELECTRICAL/DATA DETAIL 3/COM-1. BOTH ELECTRICAL AND DATA BOXES MUST BE PLACED 10" FROM CENTER LINE OF THE DEPTH OF THE CABINET OPPOSITE THE DRIVE THRU WINDOW SIDE. DRIVE THRU TIMER - SEE ELECTRICAL/DATA DETAIL 3/COM-1. 3/4" COMMUNICATION CONDUIT FROM DRIVE THRU ORDER BOX TO COMMUNICATION PANEL. TRENCH UNDER GROUND AS REQUIRED TO INSIDE OF BUILDING, BRING UP IN FURRED WALL AND ROUTE TO COMMUNICATION PANEL - VERIFY EXACT LOCATION. DUPLEX OUTLET TO BE USED FOR CO2 SENSOR POWER, ALL WIRES FROM THE SENSOR TO THE ALARM ( INSTALLED TIGHT TO THE BOTTOM OF THE CEILING ABOVE) ARE TO BE RECESSED IN THE WALL. 1 2 3 4 5 6 7 8 9 10 K E Y E D N O T E S 11 1. RUN WIRING TO P.O.S. AND PREPARATION TABLES THRU WIRING CHASE PROVIDED IN THE CABINETS. CONCEAL CONDUIT RISER TO CEILING BEHIND WALL. ARRANGE CONDUIT SO DATA WIRING CAN BE DAISY CHAINED ONE OUTLET TO THE NEXT. 2. ALL 120V RECEPTACLES IN PREP AREA ARE TO BE GFI PROTECED. ANY OTHER RECEPTACLES IDENTIFIED AS GFI PROTECTED SHALL BE GFI DEVICES, OR CONNECTED TO GFI CIRCUIT BREAKER OR CONNECTED DOWNSTREAM OF AND PROTECTED BY A GFI DEVICE. 3. PROVIDE (2) PULL STRINGS IN EACH EMPTY CONDUIT FOR DATA/PHONE LINES. 4. ALL CONDUITS MUST NOT BE MOUNTED ON WALL SURFACES ANYWHERE IN EXPOSED AREAS. ALL CONDUITS SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN WALLS. 5. ALL COVER PLATES IN PREP AREA, BACKROOM AND RESTROOMS ARE STAINLESS STEEL WITH WHITE DEVICES. IN DINING AREA DEVICES AND COVER PLATES ARE TO MATCH COLOR OF SURROUNDING SURFACES. 6. TELEPHONE BOARD/PUNCHDOWN BLOCK IS TO BE MOUNTED ABOVE THE CEILING AT THE MANAGERS DESK IN BACK PREP AREA, NOT EXPOSED TO PUBLIC. 7. COORDINATE ALL LINES TO RUN CONCEALED. PUNCH DOWN BLOCK SHOULD BE ABOVE DROP CEILING. 8. SEE ELECTRICAL/DATA PHONE BANK DETAIL ON SHEET COM-1 FOR INSTALLATION OF PHONE/DATA EQUIPMENT. 9. ALL DATA CABLES TO TERMINATE ON RJ45 CATEGORY 5e JACKS AND WIRE TO EIA/TIA 568-B.1 STANDARDS. 10. ALL DATA CABLES TO HOMERUN AND TERMINATE ON CATEGORY 5e EIA/TIA 568-B RJ45 PATCH PANELS THE NETWORK CABINET. 11. ALL CABLES TO BE CONTINUITY TESTED FOR POLARITY AND CORRECT PIN CONFIGURATION AND MACHINE LABELED. 12. NOT USED 13. ANY EXPOSED CONDUIT IN DINING ROOM MUST BE RIGID CONDUIT AND SPACED NO LOWER THAN 1 1 2" BELOW THE DECK. IF TRUSSES, JOISTS, OR BEAMS ARE PRESENT WHICH PROHIBIT CONDUIT RUNNING TIGHT TO DECK THAN THE CONDUIT MUST RUN TIGHT TO BOTTOM OF TOP CORD OF STRUCTURAL MEMBER. 14. ANY PRE-EXISTING MC CABLE EXPOSED MUST BE REPLACED WITH RIGID CONDUIT. CONDUIT AND J-BOXES MUST NOT BE MOUNTED ON WALL SURFACES ANYWHERE IN EXPOSED AREAS. ALL CONDUIT AND J-BOXES SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN WALLS. 15. REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS 12 13 14 15 (FLA)BREAKER REMARKSWIRE & CONNECTION TYPE OF NO. CIRCUITLOAD PANEL FROM CONDUITDESCRIPTIONTAG E Q U I P M E N T P O W E R S C H E D U L E PHASE VOLTAGE MOUNTING HEIGHT 1. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION, HEIGHT AND ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT PRIOR TO ROUGH-IN WITH KITCHEN EQUIPMENT SUPPLIER, AND KITCHEN ROUGH-IN DRAWINGS. 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED LOCAL DISCONNECTS AND SPECIAL ENCLOSURES (I.E., NEMA 3R, STAINLESS STEEL, ETC.) PER LOCAL CODE. 3. ELECTRICAL CONTRACTOR SHALL CHECK ROTATION OF ALL THREE PHASE MOTORS AND CORRECT ROTATION IF REVERSED. 4. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CIRCUIT BREAKER LOCK-ON DEVICES FOR ALL BRANCH CIRCUITS SERVING REFRIGERATION EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL EQUIPMENT POWER AND CONTROL TERMINATIONS. 6. ELECTRICAL COMPONENTS FURNISHED LOOSE BY KITCHEN EQUIPMENT SUPPLIER (OR BY THE ELECTRICAL CONTRACTOR AS NOTED) SHALL BE MOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR. 7. ALL FLEXIBLE CONDUIT EQUIPMENT CONNECTIONS SHALL BE: "SEAL TIGHT". P.O.S. SYSTEM ICE/DRINK DISPENSER REFRIGERATED PREP TABLE (2) SLICER 120V/1 Ø 120V/1 Ø 4.1A 4A 13.29A A A 1 25 & 27 2 #12, 3/4"C 2 #12, 3/4"C 2 #12, 3/4"C 1 #12 GRD QUAD I.G. RECEPTACLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE 12" A.F.F. IN CASEWORK IN CASEWORK 1P, 20A 1P, 20A 1P, 20A GFCI BREAKER LOCATE RECEPTACLE WITHIN CASEWORK 120V/1 Ø 3 8 13 17 27 X 6.0A A 7 2 #12, 3/4"C120V/1 Ø ICE MAKER (WATER COOLED)11.5A A 3,5 2 #12, 1 #12 GRD., 3/4"C.72" A.F.F.2P, 20A 1P, 20AGFCI RECEPTACLE2 #12, 3/4"CA36115V/1 Ø22REACH-IN REFRIGIRATOR 5A 72" A.F.F. PROVIDE LOCAL DISCONNECT FOR EVAPORATOR WALK-IN FREEZER LIGHTS (2), EVAPORATOR, DOOR HTR.2.3A A 17 2 #12, 3/4"C J-BOX VERIFY 1P, 20A120V/1 Ø 5-15 RECEPTACLE LOCATE RECEPTACLE WITHIN CASEWORK IN CASEWORK 1P, 20AGFCI RECEPTACLE A 32120V/1 Ø49TEA BREWER 15A GFCI RECEPTACLE 1P, 20A A 30 OVEN/PROOFER15A A 37,39,41 2 #12, 1 #12 GRD., 3/4"C. 8A 1P, 20AGFCI RECEPTACLE2 #12, 3/4"CB 9120V/1 ØICE/DRINK DISPENSER 4A DRIVE THRU P.O.S. SYSTEM 120V/1 Ø 4.1A 2 #12, 3/4"C 1 #12 GRD QUAD I.G. RECEPTACLE 28" A.F.F.1P, 20AB 3 3A 115V/1 Ø 12" A.F.F. GFCI RECEPTACLE 23 23A INTERLOCK WITH FREEZER EVAPORATORWALK-IN FREEZER COMPRESSOR WALK-IN COOLER COMPRESSOR 10.72A A 9,11 20A/2P DISCONNECT VERIFY 2P, 20A 20A/2P DISCONNECT208/230V/1 Ø -VERIFY 2P, 20AA13,15 208/230V/1 Ø E.C TO FIELD VERIFY BUILDING ELECTRICAL SERVICE (VOLTS,PHASE,AMPS) PRIOR TO BID. IF THERE IS ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND FIELD CONDITIONS, E.C. IS TO NOTIFY FRANCHISEE, ARCHITECT AND ENGINEER IMMEDIATELY. ELECTRICAL NOTE: ELECTRICAL CONTRACTOR TO COORDINATE ALL CONDUIT LOCATIONS WITH THE COMMUNICATIONS/DATA SUB-CONTRACTOR. E.C. SHALL F & I T.T. SWITCH AT UNIT AND WIRE COMPLETE. FAN INTERLOCKED THRU LOCAL LIGHT SWITCH0.8 FLA KW/HP/FLA REMARKSVOLTAGE/ PHASE 115/1 ØEXHAUST FAN DESCRIPTIONTAG EF-1 M E C H A N I C A L E Q U I P M E N T P O W E R S C H E D U L E 1. ELECTRICAL CONTRACTOR SHALL REFER TO ALL MECHANICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT LISTED BELOW. ANY MODIFICATION AND/OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID. 2. ELECTRICAL CONTRACTOR SHALL CHECK THE ROTATION OF ALL THREE PHASE MOTORS AND CORRECT THE ROTATION IF REVERSED. 3. ALL TEMPERATURE CONTROL AND INTERLOCK WIRING SHALL BE BY HVAC CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ALL SCHEDULED EQUIPMENT FURNISHED BY THIS CONTRACTOR FOR ARCHITECT/ENGINEER REVIEW. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF POWER WIRING TO ROOF-MOUNTED EQUIPMENT WITH MECHANICAL PIPE CURB ASSEMBLY. NO SEPARATE ROOF PENETRATIONS WILL BE PERMITTED. 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND WIRE DUCT SMOKE DETECTORS IN THE RETURN AIR PLENUM AND A FAN SHUT DOWN RELAY FOR ALL AIR SUPPLY UNITS. DETECTORS TO BE INSTALLED BY MECH. CONTR. 7. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A WEATHER PROOF, GROUND FAULT INTERRUPTER TYPE RECEPTACLE, AT AN ACCESSIBLE LOCATION FOR SERVICING ON ROOFTOP HEATING AND AIR CONDITIONING EQUIPMENT. THIS RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET AND AT THE SAME LEVEL OF THIS EQUIPMENT. M E C H A N I C A L E Q U I P M E N T P O W E R S C H E D U L E N O T E S NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. 16 WH-1 WATER HEATER "LOW BOY"REF. ELECTRICAL AND PLUMBING PLANS18KVA 208/3 ØRTU-1 RTU UNIT (EXISTING)REF. MECHANICAL PLANS LOCATE IN CASEWORK GFCI RECEPTACLE 3 #12, 1 #12 GRD., 3/4"C. 3 #12, 1 #12 GRD., 3/4"C. A 34 2 #12, 3/4"C GFCI RECEPTACLE 81" AFFCARBONATOR CENTERED ABOVE BAG N BOX16D1P, 20A120V/1 Ø 7A 115/1 Ø E.C. SHALL F & I T.T. SWITCH AT UNIT AND WIRE COMPLETE. FAN INTERLOCKED THRU LOCAL LIGHT SWITCH0.8 FLAEXHAUST FANEF-2 9 RPI AIR MERCHANDISER 115V/1 Ø 15A A 31 2 #12, 3/4"C GFCI RECEPTACLE IN CASEWORK 1P, 20A LOCATE IN CASEWORK 208V/3 Ø 28A 4 #8, 1 #10, GRD., 1" C. 50A/3P DISCONNECT 18" AFF 3P, 50A (4) WIRES PLUS A GROUND 44" A.F.F. 208/3 Ø 1 Electrical not reviewed or approved. All electrical is subject to State inspections and approvals. NOTE: UNISTRUT IS TO STOP SHORT EXACTLY 6" FROM END OF TRACK. ALL JOINTS IN UNISTRUT ARE TO BE SECURELY FASTENED - USE HEAVY DUTY JOINING PLATES. 1-1/2" DEEP P1000 UNISTRUT 3/8" ALL-THREAD ROD SPACED HORIZONTALLY AT 5'-0" O.C. MAX. LIGHTING TRACK 1-1/2" DEEP P1000 UNISTRUT SPRING NUT FLAT WASHER (2) NUTS (2) NUTS FLAT WASHER SPRING NUT METAL DECK METAL DECK3B VA R I E S FINISHED FLOOR NOTE: ALL COVER PLATES IN PREP AREA/ BACKROOM AND RESTROOMS ARE STAINLESS STEEL WITH WHITE DEVICES. IN DINING AREA DEVICES AND COVER PLATES ARE TO MATCH COLOR OF SURROUNDING SURFACES. 48 " ELECTRICIAN TO CONFIRM THAT FLOOD FIXTURES SHINE DOWNWARD OR ON WALLS UNOBSTRUCTED BY ANY STRUCTURAL OR MECHANICAL COMPONENTS. GC TO CONTACT JJ'S CONSTRUCTION DEPT. FOR DIRECTION ON HOW TO PROCEED IF LIGHTING WILL BE OBSTRUCTED. 10 ' - 6 " PR E P A R E A - C K T # A - 4 ( a ) BA C K R O O M - C K T # A - 6 ( c ) WI N D O W S I G N S CK T # A - 2 ( k ) WI N D O W S I G N S CK T # A - 1 2 ( k ) DI N I N G - C K T # A - 1 0 ( d ) ME N U S O F F I T - C K T # A - 8 ( b ) FIRE SPRINKLER ROOM 103 MEN 101 PREP 102 BACKROOM f A1 A-16f 100 DINING EXIT SIGNS ARE SUPPLIED BY TWO CIRCUITS. ONE FROM A-14 FOR NORMAL AND ONE FROM EMERGENCY CIRCUIT THAT IS 90 MIN. BATTERY BACKUP BATTERY. A-16fEF 1 abcdk I-2 A-14 A1 A-6c H A-14 A1 A-6c A-E A-14 104 WOMAN g A1 A-16g A-16gEF 2 I-2 A-14 A A-6c H A-14 EXIT SIGNS ARE SUPPLIED BY TWO CIRCUITS. ONE FROM A-14 FOR NORMAL AND ONE FROM EMERGENCY CIRCUIT THAT IS 90 MIN. BATTERY BACKUP BATTERY. A-E A-14 J A-8b J A-8b J A-8b J A-8b J A-8b A A-6c A A-4a A A-4a A A-4a A A-4a A A-4a K1 A-10d K1 A-10d K1 A-10d K1 A-10d K1 A-10d K1 A-10d K1 A-10d K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K I-2 A-14 K RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 ELECTRICAL LIGHTING PLAN 1/4" = 1'-0"A F I X T U R E S C H E D U L E N O T E S E.C TO FIELD VERIFY BUILDING ELECTRICAL SERVICE (VOLTS,PHASE,AMPS) PRIOR TO BID. IF THERE IS ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND FIELD CONDITIONS, E.C. IS TO NOTIFY FRANCHISEE, ARCHITECT AND ENGINEER IMMEDIATELY. ELECTRICAL NOTE: ELECTRICAL CONTRACTOR TO COORDINATE ALL CONDUIT LOCATIONS WITH THE COMMUNICATIONS/DATA SUB-CONTRACTOR. R E F L. C E I L I N G N O T E S 1. REFER TO MECHANICAL FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2. REFER TO ELECTRICAL FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3. G.C. WILL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 4. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES BY G.C. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR, TO CENTER OF SWITCHES AND 6" FROM DOOR FRAME U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GAINED TOGETHER AND FINISHED WITH ONE COVER PLATE. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 8. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 9. FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC (UL) LABELED DEVICES THROUGHOUT. 10. G.C. TO INSURE THAT EXIT SIGNS & EMERGENCY LIGHTING TO MEET ADA/TITLE 24 REQUIREMENTS. 1. EXHAUST FAN IN RESTROOM TO BE LIGHT ACTIVATED. 2. ALL ACRYLIC LENS SHALL BE 100% VIRGIN ACRYLIC. 3. ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TRIM LINE T8 WARM WHITE F32T8/SP35/RS 4. ALL BALLASTS SHALL BE RAPID START ELECTRONIC ENERGY SAVING TYPE. 5. ALL EXIT SIGNS AND EMERGENCY LIGHT FIXTURES ARE TO BE STRICT ACCORDANCE WITH THE LOCAL FIRE PREVENTION CODE AUTHORITY. ANY MODIFICATIONS TO UPGRADE SYSTEM SHALL BE INCLUDED IN THE BASE BID. ALL EXIT SIGNS ARE TO BE INSTALLED IN A VISIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WHERE NECESSARY TO DROP A SIGN BELOW AN OBSTRUCTION 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY CLIPS, SCREWS, RIVETS, ETC., TO SECURELY FASTEN RECESSED LAY-IN LIGHTING FIXTURES TO CEILING FRAMING GRID WORK. 7. ALL LIGHTING FIXTURES SHALL BEAR THE APPROPRIATE UL LABEL FOR THE APPLICATION AND UNION LABEL WHERE REQUIRED. 8. ALL LIGHTING FIXTURES SHALL BE SHATTER PROOF OR COMPLETELY SHIELDED/COVERED. 9. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS, EQUIPMENT, S.E.S., AND EXTENT OF ELECTRICAL ITEMS. PROVIDE AND INCLUDE IN BID ALL REQUIRED ITEMS TO ENSURE PROPER SCOPE OF WORK. NORTH TYPICAL MOUNTING HEIGHTS 1/4" = 1'-0"1 SWITCH BANK DETAIL 2 E-2 LIGHTING PLAN ELECTRICAL J 120 CENTERED IN WIDTHRECESSEDRECESSED LED DOWNLIGHT WITH 5" ROUND LENSED PHILIPS LIGHTOLIER LYTECASTER LED 5", ROUND LENSED FRESNEL LENSLITE (1) 20W LED---- L I G H T I N G F I X T U R E S C H E D U L EL I G H T I N G F I X T U R E S C H E D U L E DESCRIPTIONFIXTURE TYPE TYPE LAMPMANUFACTURER'S KEC STOCK/ITEM # CAT. NO. VOLTAGE BALLAST TYPE MOUNTINGLENS MOUNTING HEIGHT REMARKS NOTES: NO SUBSTITUTIONS ON ANY FIXTURES.1. ALL LIGHT FIXTURES, LAMPS AND CEILING FANS ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTRACTOR. CONTACT KEC DESIGN, 301 MERCURY DRIVE, CHAMPAIGN, IL. 61822. PH: (217) 356-1640. W/RED LETTERS CLEAR ACRYLIC UNIVERSALSURFACE CLEAR ACRYLIC W/RED LETTERS I-2 I-3 H K FLOOD LIGHT LIGHTOLIER # LT08RWF830BK 8.9 W 3000K LINE VOLTAGE LED TRACKHEAD TO ACCENT GLASS GUARD AT COUNTER AND CHIP / COOKIE DISPLAY AND DINING AREA K1 CIRCUIT TRACK LIGHTOLIER: 600*NBK *CONTRACTOR TO VERIFY LENGTHS PRIOR TO ORDERING 1- CIRCUIT LINE VOLTAGE TRACK MOUNT HEIGHT - ( 10'-6" ) -- -- -- -- -- ------ -- -- -- -- UNIVERSAL UNIVERSAL SURFACE SURFACE CIRCUIT TRACK MOUNT HEIGHT - ( 10'-6" ) LTC -- -- --SURFACE 365 DAYS PROGRAMMABLE-- --LIGHTING TIME CLOCK KLITE #1481A 2'X4' LAY-IN LAMP RECESSED FLUORESCENT FIXTURE WITH ONE BALLAST PHILIPS DAY-BRITE # 2TG8432-01-UNV-1/4-EB A1 2'X2' LAY-IN LAMP RECESSED FLUORESCENT FIXTURE WITH ONE BALLAST KLITE #1241 120 ELECTRONIC CEILINGACRYLIC RECESSED KLITE #1482A-E 2'X4' LAY-IN LAMP RECESSED FLUOR. FIXTURE WITH ONE BALLAST - WITH EMERGENCY BATTERY BACK-UP PHILIPS DAY-BRITE # 2TG8432-01-UNV-1/4-EB E1 120 ELECTRONIC ACRYLIC RECESSED 120 ELECTRONIC ACRYLIC RECESSED COORDINATE EMERGENCY FIXTURES TO BE NIGHT LIGHTS (KEEP ON SEPARATE CIRCUIT FROM TYP. PREP LIGHTS) CEILING CEILING(4) 32W T8 (4) 32W T8 PHILIPS DAY-BRITE # 2TG8231U6R-01-UNV-1/2-EB (2) 32W T8 LOCATE DIRECTLY NEXT TO NETWORK CABINET ABOVE MANAGERS DESK KLITE #2114 KLITE #2115 KLITE #2112 3.6V EMERGENCY LIGHTING 0.6W (120V) WITH BATTERY BACK-UP COMBO EXIT SIGN AND EMERGENCY LIGHT 3W WITH BATTERY BACK-UP WITH (1) 2W REMOTE CAPACITY PHILIPS CHLORIDE # VLLCR PHILIPS CHLORIDE # VLLU PHILIPS CHLORIDE # VLLCR2R (2) 1W LED (2) 1W LED COMBO EXIT SIGN AND EMERGENCY LIGHT 3W WITH BATTERY BACK-UP 3.6V (2) 1W LED 3.6V INTERMATIC-T101 SINGLE LINE DIAGRAM N.T.S.A CONTRACTOR TO SITE VERIFY ALL EXISTING CONDITIONS PRIOR TO BID AND MAKE ALL ALLOWANCES IN BID NECESSARY FOR COMPLETE INSTALLATION OF ELECTRICAL SERVICE. JIMMY JOHNS INTERIOR BUILDING SERVICE NEW PANEL "A" 120/208V 3PH/4W 200 AMPS RELOCATED PANEL U100 "B" 120/208V 3PH/4W 400 AMPS EXTEND EXISTING (2) SETS OF 3 # 3/0, 1 # 3/0 NEUTRAL 1 # 2 GROUND 2" CONDUIT 4 # 3/0, 1 # 6 GND. 2" CONDUIT EXISTING 1600A MAIN SWITCH BOARD (MSB) 208/120V, 3PH, 4W, 65K AIC, NEMA 3R M E-3 PANELS SCHEDULES ELECTRICAL G E N E R A L R E Q U I R E M E N T S RCHITECTURE ESIGN CC VB AS NOTED 11.DECEMBER.2019 A19167 ES T E S P A R K , C O L O R A D O 8 0 5 1 7 42 0 S T E A M E R D R I V E , S U I T E 1 0 0 ST O R E # 4 0 4 0 JI M M Y J O H N ' S 11 . D E C E M B E R . 2 0 1 9 3 C I T Y C O M M E N T 9. D E C . 2 0 1 9 2 O W N E R R E V I E W 13 . N O V . 2 0 1 9 1 C I T Y / H E A L T H C O M M E N T S 305645 JOHN CHRISTOPHER COOPER EXP. DATE: 10-31-2021 GENERAL REQUIREMENTS A. E.C. SHALL COORDINATE FULLY WITH OTHER CONTRACTORS ASSOCIATED WITH THIS PROJECT TO VERIFY ALL EQUIPMENT LOCATIONS, CONNECTION REQUIREMENTS, ELEVATIONS AND LOCATIONS OF PIPES, CONDUITS AND DUCTS TO PREVENT CONFLICTS DURING CONSTRUCTION. ANY RELOCATION OR REROUTING OF EQUIPMENT, PIPES, CONDUITS, DUCTS OR MATERIALS RESULTING FROM A LACK OF COORDINATION BETWEEN CONTRACTORS WILL BE AT THE CONTRACTORS EXPENSE. B. EQUIPMENT ROUGH-INS SHOWN ARE ACCURATE TO THE BEST OF DESIGNER'S KNOWLEDGE. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN. THEREFORE,THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE E.C. TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR. C. E.C. SHALL FURNISH AND INSTALL ALL REQUIRED DISCONNECT SWITCHES AND MOTOR STARTERS TO ALL EQUIPMENT. D. E.C. SHALL REVIEW WITH OWNER AND SIGNAGE MANUFACTURER, REQUIREMENTS AND LOCATION OF BUILDING SIGNAGE PRIOR TO CONSTRUCTION AND PROVIDE 120VAC CONNECTION AS REQUIRED. E. E.C. SHALL PROVIDE AS-BUILT DRAWINGS AT JOB COMPLETION TO ARCHITECT. F. ALL WORK SHALL BE INSTALLED PER ALL GOVERNING CODES. G. SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS INCLUDING RESTROOM FIXTURES. BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. H. SUBCONTRACTOR IS TO SUPPLY AND INSTALL UNISTRUT AND 3/8" THREADED ROD TO HANG/SUPPORT LIGHTING. RACEWAY SYSTEMS A. ALL BRANCH CIRCUIT WIRING SHALL BE ROUTED IN EMT, RIGID OR ELECTRICAL METALLIC TUBING. USE STEEL SET SCREW TYPE FITTINGS ON ALL EMT. B. CONDUIT SHALL BE SUPPORTED AT INTERVALS PER NEC REQUIREMENTS AND SHALL BE SECURELY FASTENED TO BUILDING WITH AN APPROVED FASTENING SYSTEM. C. ALL NEW CONDUIT TO BE CONCEALED IN WALLS. PATCH/PAINT IF NECESSARY. WIRING, WIRING DEVICES, PLATES AND GROUNDING A. ALL WIRING SHALL CONSIST OF COPPER CONDUCTORS WITH THERMOPLASTIC INSULATION RATED FOR SIX HUNDRED (600) VOLTS. ALL WIRING INSULATION SHALL BE HEAT AND MOISTURE RESISTANT TYPES THW, THWN, OR THHN FOR INTERNAL AND DRIVE LOCATIONS. B. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG FOR ALL BRANCH CIRCUITS (I.E. RECEPTACLES, LIGHTING, EQUIPMENT POWER, ETC.). MINIMUM CONDUCTOR SIZE SHALL BE NO. 10 AWG FOR ALL FEEDER CIRCUITS TO MECHANICAL EQUIPMENT (I.E U-1, CONDENSERS, ETC.) C. ALL SPLICED OR CONNECTIONS SHALL BE MADE IN OUTLET BOXES, JUNCTION BOXES OR EQUIPMENT WHERE ACCESSIBLE. D. CONDUCTORS SHALL BE PULLED WITHOUT THE USE OF OIL OR GREASE. WIRE PULLING LUBRICANTS WHICH ARE APPROVED FOR USE WITH CONDUCTOR INSULATION MAY BE USED. CARE SHALL BE TAKEN IN PULLING WIRE TO ASSURE THAT MAXIMUM ALLOWABLE PULLING TENSION OF WIRE IS NOT EXCEEDED. WIRING WITH DAMAGED CONDUCTORS OR INSULATION WILL NOT BE ACCEPTED. E. ALL PLUG-IN DEVICES SHALL BE GROUNDED TYPE. A GROUNDING JUMPER FROM RECEPTACLE TO OUTLET BOX SHALL BE INSTALLED WHERE CONDUIT SYSTEM IS USED FOR GROUND. F. INSTALL INSULATED GREEN GROUNDING CONDUCTOR (NO. 12 AWG MINIMUM) IN RACEWAYS AS INDICATED ON DRAWINGS AND IN ALL NON-METALLIC RACEWAYS PER NEC. G. SWITCHES FOR LIGHTING CONTROL SHALL BE INDUSTRIAL GRADE. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS PLATES IN THE KITCHEN AND RESTROOMS. SIDE WIRED ONLY, TWENTY (20) AMP, ONE HUNDRED TWENTY/TWO HUNDRED SEVENTY-SEVEN (120/277) VOLT. H. DUPLEX RECEPTACLES SHALL BE INDUSTRIAL GRADE, THREE (3) WIRE GROUNDING, WHITE COLOR, FINDER GROOVE, TWENTY (20) AMP, NEMA 5-20R 125 VAC. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS STEEL PLATES IN THE KITCHEN AND RESTROOMS. I. PLATES SHALL BE FURNISHED AND INSTALLED FOR ALL WIRING DEVICES, TELEPHONE OUTLETS, JUNCTION BOXES, ETC. J. PLATES FOR FLUSH MOUNTED DEVICES SHALL MATCH THE SURROUNDING FINISH, EXCEPT IN THE KITCHEN/PREP AREA AND RESTROOMS WHERE THEY SHALL BE STAINLESS STEEL SURFACE MOUNTED BOXES SHALL BE GALVANIZED STEEL. K. E.C. SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM; REGARDLESS OF CIRCUITING INDICATED. L. ALL DUPLEX RECEPTACLES INSTALLED IN KITCHEN AND PREPERATION AREA ARE TO BE GFCI RATED, WHERE NOT PROTECTED BY A GFCI CIRCUIT BREAKER. M. THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISBILE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. DENOTES GFCI BREAKERS DENOTES HACR CIRCUIT BREAKER DENOTES LOCK ON CIRCUIT BREAKER FED FROM METER BUS SIZE: 40 AMP ph A ph B ph C MAINS: 400 AMP MLO 26585 VA MOUNTING: RECESSED 24740 VA A.I.C. RATING:22,000 A.I.C.22055 VA GROUND BUS: YES ISO GRD. BUS: YES 73380 VA VOLTAGE:120 / 208V, 3ph, 4W 204 A VOLT AMPS VOLT AMPS CCT BRKR ID DESCRIPTION A ph B ph C ph A ph B ph C ph DESCRIPTION ID BRKR CCT 1 20/1 DRIVE THRU MENU 500 3600 RTU-1 (EXISTING)50/3 2 3 20/1 DRIVE THRU P.O.S. 500 3600 4 5 20/1 DRIVE THRU COMM. 500 3600 6 7 20/1 DRIVE THRU TIMER 500 1500 UH-2 (EXISTING)30/2 8 9 20/1 DRINK DISPENSER 500 1500 10 11 20/1 EXTERIOR SIGN 600 0 SPARE 20/1 12 13 20/1 EXTERIOR SIGN 600 6000 WATER HEATER 60/3 14 15 20/1 EXTERIOR SIGN 600 6000 16 17 20/1 EXTERIOR SIGN 600 6000 18 19 20/1 SPARE 0 0 SPARE 20/1 20 21 20/1 SPARE 0 0 SPARE 20/1 22 23 20/1 SPARE 0 0 SPARE 20/1 24 25 20/1 SPARE 0 0 SPARE 20/1 26 27 20/1 SPARE 0 0 SPARE 20/1 28 29 20/1 SPARE 0 0 SPARE 20/1 30 31 20/1 SPARE 0 0 SPARE 20/1 32 33 20/1 SPARE 0 0 SPARE 20/1 34 35 20/1 SPARE 0 0 SPARE 20/1 36 37 200/3 PANEL "A" 13885 0 SPARE 20/1 38 39 12040 0 SPARE 20/1 40 41 10755 0 SPARE 20/1 42 TOTALS:15485 13640 12455 11100 11100 9600 P A N E L S C H E D U L E U 1 0 0 " B " ( R E - W O R K ) FED FROM PANEL U100 "B" BUS SIZE: 200 AMP ph A ph B ph C MAINS: 200 AMP M.C.B. 13885 VA MOUNTING: RECESSED 12050 VA A.I.C. RATING:22,000 A.I.C.10755 VA GROUND BUS: YES ISO GRD. BUS: YES 36690 VA VOLTAGE:120 / 208V, 3ph, 4W 102 A VOLT AMPS VOLT AMPS CCT BRKR ID DESCRIPTION A ph B ph C ph A ph B ph C ph DESCRIPTION ID BRKR CCT 1 20/1 P.O.S.492 600 NEON SIGNS 20/1 2 3 20/2 ICE MAKER 1200 896 PREP LIGHTING 20/1 4 5 1200 448 BACKROOM LIGHTING 20/1 6 7 20/1 SLICER 700 100 MENU SOFFIT 20/1 8 9 20/2 FREEZER EVAP. 1286 370 DINING LIGHTING 20/1 10 11 1286 600 NEON SIGNS 20/1 12 13 20/2 COOLER EVAP. 1286 273 EM & NIGHT LIGHTS 20/1 14 15 1286 456 RESTROOM LIGHTS 20/1 16 17 20/1 FRZR / LTS / EVAP 473 500 NETWORK CABINET 20/1 18 19 20/1 WP HEAT TAPE 500 720 OFFICE RECEPT. 20/1 20 21 20/1 SPARE 0 200 SMOKE DETECTOR 20/1 22 23 20/1 SPARE 0 500 TIME CLOCK 20/1 24 25 20/1 PREP TABLE 1508 558 DRIVERS BOX 20/1 26 27 20/1 PREP TABLE 1508 500 DRIVERS P.O.S. 20/1 28 29 20/1 PREP AREA 500 1000 DRINK DISPENSER 20/1 30 31 20/1 RPI AIR MERCH.1800 1800 TEA BREWER 20/1 32 33 20/1 CO2 SENSOR 400 400 CARBONATOR 20/1 34 35 20/1 SPARE 0 700 REFRIGERATOR 20/1 36 37 50/3 OVEN/PROOFER 3548 0 SPARE 20/1 38 39 3548 0 SPARE 20/1 40 41 3548 0 SPARE 20/1 42 TOTALS: 9834 9228 7007 4051 2822 3748 P A N E L S C H E D U L E " A " ( N E W ) DENOTES GFCI BREAKERS DENOTES HACR CIRCUIT BREAKER DENOTES LOCK ON CIRCUIT BREAKER