Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS New SFD 445 Pawnee Dr 2020-01-24
APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 12/18/2018 REVIEWED BY ______________________ CONSTRUCTION TYPE _______________ OCCUPANCY CLASSIFICATION ________ SPRINKLERED ______________________ 01/24/2020 This structure must comply with the requirements of the 2017 National Electrical Code LLV VB R3 NO Reviewed by SAFEbuilt 01/24/2020 General Notes: -All rooms to be AFCI except bath, utility and unfinished rooms -Bath, utility and unfinished rooms to be GFCI -Backwater valves to remain accessible -1/2” dry wall req’d for enclosed usable space under stairs -Float all walls with treated plates -Smoke alarms req’d in each sleeping room -Smoke/CO alarms req’d w/in 15’vicinity of bedroom exteriors -Min 1 emergency escape and rescue opening req’d per bedroom 2015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 Reviewed by SAFEbuilt 01/24/2020 General Notes: -Min (1) emergency escape and rescue opening req’d per bedroom -Glazing to be tempered per R308 -Min (1) programmable thermostat req’d -Smoke alarm req’d in each sleeping room -Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior. -Fireblock/Draftstop all chases and penetrations Tempered Tempered Reviewed by SAFEbuilt 01/24/2020 Reviewed by SAFEbuilt 01/24/2020 General Notes All Elevations: -Asphalt shingles to meet 175 MPH wind-speed -All stone, stucco and siding to have barrier underneath at exterior walls -Ice barrier underlayment required -Sills less than 24” w/72+” of fall req fall protection -Roof ventilation per R806 -All stairs, landings, guards, rails and walking surfaces to comply with R311 and R312 Reviewed by SAFEbuilt 01/24/2020 General Notes All Elevations: -Asphalt shingles to meet 175 MPH wind-speed -All stone, stucco and siding to have barrier underneath at exterior walls -Ice barrier underlayment required -Sills less than 24” w/72+” of fall req fall protection -Roof ventilation per R806 -All stairs, landings, guards, rails and walking surfaces to comply with R311 and R312 Reviewed by SAFEbuilt 01/24/2020 Reviewed by SAFEbuilt 01/24/2020 WALL TYPE TYPE 1 (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 7 16" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 4" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/5D COOLER NAILS, 7" O.C. EDGE, 12" O.C. FIELD TYPE 2 (SHEAR WALL)- (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 7 16" STRUCTURAL PANEL, UN-BLOCKED NAIL W/8D COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/5D COOLER NAILS, 7" O.C. EDGE, 12" O.C. FIELD TYPE 3 (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 1 2" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 3" O.C. EDGE, 3" O.C. FIELD INTERIOR (OPTIONAL)- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/5D COOLER NAILS, 4" O.C. EDGE, 12" O.C. FIELD NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR ALL NON-STRUCTURAL WALL ASSEMBLIES. 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 1 8 DA B MAIN FLOOR BRACED WALL PLAN 0'4'8'2' SCALE: 1/4" = 1'16' 1/6/20 Reviewed by SAFEbuilt 01/24/2020 WALL TYPE TYPE 1 (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 7 16" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 4" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/5D COOLER NAILS, 7" O.C. EDGE, 12" O.C. FIELD TYPE 2 (SHEAR WALL)- (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 7 16" STRUCTURAL PANEL, UN-BLOCKED NAIL W/8D COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/5D COOLER NAILS, 7" O.C. EDGE, 12" O.C. FIELD TYPE 3 (SHEAR WALL)- CONCRETE WALL PER ARCHITECTURAL DRAWINGS NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR ALL NON-STRUCTURAL WALL ASSEMBLIES. 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 1 8 DA B BASEMENT BRACED WALL PLAN 0'4'8'2' SCALE: 1/4" = 1'16' 1/6/20 Reviewed by SAFEbuilt 01/24/2020