HomeMy WebLinkAboutPLANS Residential Remodel 575 Audubon St 2023-11-158' 9 1/2" 7' 8" 8' 9 1/2" 7' 8" 6' 11/16" 2' 10 3/4" 6 7/8" 2' 8" 8' 9 1/2" 7' 8" 8' 9 1/2" 7' 8" 6' 1 11/16" 2' 10 1/2" 6 7/8" 2' 8" Existing Bathroom layout in basement Proposed bathroom layout in basement Bedroom area Bedroom area Homeowner: Judy Foley Basement Bath Conversion 575 Audobon Street Estes Park, CO 80517 3038187141 judychang@outlook.com Contractor: Colorado Living LLC 3525 N Cascade Avenue Colorado Springs, CO 80907 719-332-3247 alehr@getcoloradoliving.com Scope of work: In basement bathroom, replace the existing soaker tub with a pre-fabricated shower base The base size will be 30" x 60" x 2", the drain position will remain LH. not built on site. We will remove part of the wall cladding on the wet wall to replace the shower valve with a Lahara valve and trim and replace the wallboard with Hardie board and corrosive resistant connections as per your local jurisdictional requirements. If the wet wall is an outside wall, we will replace the insulation in the wall according to 2021 IECC R503.1.1 exception 2. We will install a 5 foot TEMPERED glass door shower enclosure for the entrance into the shower space. We will then wrap all three shower walls with impervious, acrylic wall sheets. The rest of the bathroom shall remain "as is". No other contractor will be involved in our installation. No framing (already existing) No mechanical ( already existing) No electrical (already existing) CO detectors and SD's shall be in their proper places and in working order at the final inspection. WE WILL DEMO UP TO 32sft so as not to be required to test for asbestos. Drawn by Colorado Living LLC/al alehr@getcoloradoliving.com 1/4" = 1' scale. Exterior walls adjacent to showers and tubs shall provide air barrier & insulated. Provide Anti-Scald Valve on tub/shower Cement based substrate or equal on shower/tub walls The entire building must be provided with Smoke Detectors located as required by code. CO Detectors are Required wihtin 15 ft. of ALL Bedrooms Freeze Protect pipes per P2603.5 See 410.10 (D) for new requirements for where and what type of fixtures can be installed in areas containing bathtubs/showers All work shall be performed by Licensed Contractors OR work shall be performed by the homeowner residing in the dwelling. PE R M I T # 2 3 - E P - 0 0 5 9 9 - - Fi e l d C o p y Pr i n t o u t l e g i b l y & i n c o l o r a n d h a v e o n s i t e f o r i n s p e c t o r RE V I E W E D B Y S A F E b u i l t - P B L A N D DO NOT COVER WORK UNTIL IT HAS BEEN APPROVED BY INSPECTION - IF YOU HAVE FAILED A ROUGH INSPECTION YOU MUST HAVE AN APPROVED REINSPECTION BEFORE YOU COVER THE WORK UP. PLANS AND CONSTRUCTION SHALL MEET THE 2021 IRC AND ALL APPLICABLE MUNICIPAL CODES & ORDINANCES APPROVED by SAFEbuilt; 2021 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 11/15/2023 Glazing in walls containing or facing hot tubs, spas, bathtubs, showers, indoor or outdoor pools where the bottom exposed edge of glazing is less than 60" vertically above any standing or walking surface - shall be safety glazing (R308.4.5) Showers shall be finished 72 inches above the floor with a non-absorbent material. Shower door minimum clear opening width is 24 inches and open outward Follow Manufacturer's installation instructions: Manufacturer's installation instructions, as required by code, shall be available on the job site at the time of inspection. R106.1.2 PE R M I T # 2 3 - E P - 0 0 5 9 9 - - Fi e l d C o p y Pr i n t o u t l e g i b l y & i n c o l o r a n d h a v e o n s i t e f o r i n s p e c t o r RE V I E W E D B Y S A F E b u i l t - P B L A N D PERMIT #23-EP-00599 -- Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEbuilt - PBLAND