Proposal Request (PR)
PROJECT: Estes Valley Community Center PR # : Four (04) Revised
Date: May 1, 2017
Project #: 16003
Rep: RLH Engineering
Chuck Jordan, Project Manager
Architect: Ohlson Lavoie Collaborative
616 E. Speer Blvd.
Denver, Colorado 80203-4213
(303) 294-9244, Tel
(303) 294-9440, Fax
Owner: Estes Valley Recreation and Parks District
Tom Carosello, Executive Director
www.olcdesigns.com
Contractor: Adolfson & Peterson Construction
Chris Cooper, Project Manager
Tom Purcell, Superintendent
Cc:
Please submit an itemized quotation for changes in the Contract Sum and/or Time incidental to proposed modifications to the
Contract Documents described herein. This is not a change order nor a direction to proceed with the work described herein.
DESCRIPTION: (Continued on attached sheets)
1. Demolish existing flat roof systems. Inspect substrate and replace when deteriorated. Perform
structural improvements required in attached structural analysis and described in structural drawings.
Replace with EPDM roofs as described on the attached documents, to include manufacturer-
recommended flashing and fasteners.
2. Existing sloped metal roofs to remain. Perform structural improvements required in attached structural
analysis and drawings. Cover existing metal standing seam roofs with Sika Sarnafil metal retrofit system
and new PVC membrane with Decor system profiles to match that in base scope of work.
3. Identify and repair roof drain leaks. Reseat existing drains within new roofing system. Replace roof
hatch and re-locate roof ladder as indicated.
4. Demolish EIFS cladding system. Inspect substrate and replace when deteriorated. Provide the cladding
described in the attached documents, to include:
1. Polyiso rigid insulation boards with taped seams for air and water barrier in same manner as
base scope of work.
2. Knight Wall Systems Vertical CI-GIRT and proprietary fasteners, fastened through insulation to
existing 2x6 wood studs (or in indicated areas, cmu), 16" on center. Confirm with Knight required
fastener length and spacing to resist 55.2 psf design wind pressure.
3. HardiePlank smooth fiber cement siding, primed and field-painted.
4. Siding accessories to include: easytrim or similar reveals at outside and inside corners, primed
HardieTrim boards at windows, fasteners and all manufacturer-recommended flashing.
5. Metal coping at former EIFS parapets, sized to cover complete wall assembly, with any related
anchors, nailers and fasteners.
5. Provide new glazing for Kalwall skylight; new sealant per Kalwall manufacturer.
5/1/17 @ 16:40 V:\16003\CA\08_PR\PR #004 Existing Building Exterior\Proposal Request
004R.docx by LM
Page 2 of 2
6. Replace four skylights at south elevation with fixed units, to include curb and flashing.
7. Other fenestration to remain unless damaged, in which case replace in kind. Provide new perimeter
sealant at all windows.
8. Replace existing light fixtures with LEDs as described on the attached electrical sheets.
9. Provide ceiling fans CF-4 and CF-5 as described in base scope of work.
10. Replace six (6) deteriorated indoor hollow metal doors with aluminum doors to match those in base
scope of work. Replace two exterior hollow metal doors with new hollow metal doors with a 45 minute
fire resistance rating. Refer to base spec sections 08 1113 and 08 4313.
11. Demolish existing acoustic panels in natatorium. Inspect substrate and replace when deteriorated
(note: interior plywood is structural; replace in kind) and replace with Tectum Kerfed Wall Panels.
12. Repair epoxy coating at pool deck where damaged.
13. Refinish existing glulam beams.
14. Refinish existing bleachers.
15. Re-paint existing ductwork wherever exposed. Refer to Dry Fall paint in base spec 09 91235.
ATTACHMENTS:
1. Estes Park Community Center IEBC Reroofing Roof Diaphragm Evaluation
2. Architectural Drawings:
AX101 - FLOOR AND CEILING PLANS
AX102- ROOF PLANS
AX201 - EXTERIOR ELEVATIONS
AX202 - EXTERIOR ELEVATIONS
AX211 - INTERIOR ELEVATIONS
AX301 - SECTIONS AND DETAILS
AX302 - SECTIONS AND DETAILS
AX303 - SECTIONS AND DETAILS
3. Structural Drawings:
S003 - NOTES
S004 - ROOF PLAN - SOUTH
S108 - ROOF PLAN- EXISTING
S561 - WOOD DETAILS
3. Electrical Drawings:
E0.0 - ELLECTRICAL COVER SHEET
E1.0 - ELLECTRICAL LIGHTING PLAN
E2.0 - ELLECTRICAL DETAILS
E3.0 - ELECTRICAL CODE COMPLIANCE FORMS
4. Additional specifications (refer otherwise to base scope of work):
09 8400 ACOUTSICAL WALL TREATMENTS
April 17, 2017
Robert McDonald
Ohlson Lavoie Collaborative
616 East Speer Boulevard
Denver, Colorado 80203
Re: Estes Park Community Center IEBC Reroofing Roof Diaphragm Evaluation
Martin/Martin, Inc. Project No.: 16.0117.S.02
Mr. McDonald,
Per your request, Martin/Martin, Inc. completed a review of the existing Estes Park Community Center Pool
Building to evaluate the capacity of the roof framing, in order to support gravity load from the new roof and
to verify compliance with the International Existing Building Code (IEBC) 2015 Section 707.3.2. This section
states:
Where roofing materials are removed from more than 50% of the roof diaphragm or section of a
building located where the ultimate design wind speed, Vult, is greater than 115 mph or in a special wind
region, roof diaphragms, connections of the roof diaphragm to roof framing members, and roof-to-wall
connections shall be evaluated for the wind loads specified in the International Building Code, including wind
uplift. If the diaphragms and connections in their current condition are not capable of resisting at least 75%
of those wind loads, they shall be replaced or strengthened in accordance with the loads specified in the
International Building Code.
ASSUMPTIONS:
The following assumptions were made during our review:
A. The as-built construction is in substantial conformance with the original building structural
Construction Documents, entitled Estes Park Swimming Pool, dated August 28, 1985.
B. The as-built construction of structural decking, framing, and connections are not damaged or
deteriorated.
After the existing roofing is removed, the existing decking and plywood should be inspected for damage and
if found, brought to the attention of Martin/Martin, Inc for revised recommendations.
Estes Park Community Center IEBC Reroofing Roof Diaphragm Evaluation
April 17, 2017
P a g e 2 | 4
SUMMARY OF EXISTING CONDITIONS:
Per the Town of Estes Park Building Code requirements, a building in Risk Category III has a wind speed, Vult,
of 190 mph. Because preliminary documents provided by Ohlson Lavoie Collaborative show the roofing and
insulation being replaced on more than 50% of the roof, this analysis is required by the 2015 IEBC.
Under the 2012 International Building Code (IBC), conformance with the IEBC was optional, whereas with
the 2015 IBC, which is currently adopted by the Town of Estes Park, conformance to the 2015 IEBC is
required. The intent of this code provision is that during re-roofing operations, while the roofing is removed,
there is an excellent opportunity to strengthen older roof diaphragms that are less safe than comparable
buildings designed under current building codes. The existing building was designed under the 1982 Uniform
Building Code (UBC) which was released prior to the front range and mountains of Colorado being
designated as special wind regions. The current code wind speeds were adopted based on wind studies
performed by Cermak Peterka Petersen, Inc. in 2013, as recommended by the Structural Engineer’s
Association of Colorado, and significantly increase the design wind load over what was required in the 1982
UBC.
During our review of the existing building, we have verified that the new roofing gravity loads do not
increase the forces in roof framing members by more than 5%. As stipulated in the IEBC, when member
forces are increased by less than 5% by a building alteration, no strengthening of building members is
required.
However, there are several roof diaphragm conditions that were not capable of resisting 75% of the current
wind design loads. The areas that do not meet this criterion are as follows:
Sloped Roofs (Between Grids 5-13/B-C, 1-2/C-G, & 3-13/D-F):
A. Nailing of plywood to roof joists for wind uplift
High Flat Roof (Between Grids 2-13/C-G):
A. Nailing of existing decking to existing glulam beams for wind uplift
B. Existing decking being used as a diaphragm (and diaphragm chord) to resist lateral wind loads
C. Connections of diaphragm to perimeter walls for transfer of lateral wind loads
D. Connections between popped-up center section of roof to remainder of the high flat roof
Lower Flat Roofs (Between Grids 3-13/G-H & 13-14/B-H):
A. Nailing of plywood to joists/trusses for wind uplift at building edges
B. Connections of diaphragms to perimeter walls
C. Existing plywood being used to resist diaphragm chord forces due to lateral wind loads
Each of these items will need to be addressed through a complete set of structural drawings showing the
modifications required to bring these components into compliance with the requirements of the current
building code.
Estes Park Community Center IEBC Reroofing Roof Diaphragm Evaluation
April 17, 2017
P a g e 3 | 4
SUMMARY OF REQUIRED MODIFICATIONS:
Sloped Roofs:
All plywood under the existing standing seam metal roof will require additional nailing to existing framing to
resist wind uplift.
High Flat Roof:
All existing wood roof decking will need to have new wood screws added to provide adequate connection of
the decking to the existing glulam beams to resist wind uplift. New 5/8” plywood sheathing will need to be
placed over the existing decking and fastened with 10d nails at a tight spacing to meet diaphragm
requirements. Care will be required not to over-drive nails, as nails projecting into the building below
decking will not be permitted. Light gauge metal straps will be installed on top of the new plywood along
existing Grids C, D, F, & G to meet diaphragm chord requirements. Additional clips will be needed between
the diaphragm and the perimeter walls, as well as between the diaphragm and the center pop-up roof to
provide adequate lateral load transfer to the perimeter walls.
Lower Flat Roofs:
Based on our knowledge of Adolfson & Peterson’s anticipated construction plan, the existing 5/8” plywood
on the low roof portion north of existing Grid line G will be removed to aid in the existing roof strengthening
required due to new snowdrift loads imposed by the new community center building which is already
included in the current Construction Documents. At these locations, new bolts will need to be drilled
between the existing wood sill and the concrete masonry walls. The removed plywood will be replaced with
new 5/8” plywood sheathing with 32/16 min span rating. Required nailing will be shown on the construction
drawings. Additional clips between the diaphragm and the wood framed wall along existing Grid line G will
be required to provide adequate lateral load transfer to the wall. Light gauge metal straps will need to be
installed on top of the new plywood along existing Grid line G and at masonry control joints along existing
Grid H to meet diaphragm chord requirements.
Based on our review, existing plywood will also need to be removed adjacent to existing Grid line 14 to allow
new bolts to be drilled between the existing wood sills and the concrete masonry walls to provide adequate
lateral load transfer to the perimeter wall. Light gauge metal straps will need to be installed on top of the
new plywood at masonry control joints along existing Grid line 14 as well as on top of the existing plywood
along existing Grid line 13 to meet diaphragm chord requirements. Additional clips between the diaphragm
and the wood framed shear wall along existing Grid line 13 will also be required to provide adequate lateral
load transfer to the wall.
At all low roofs within 7’ of a building edge, additional nails from the plywood to roof framing will be
required to resist wind uplift.
Estes Park Community Center IEBC Reroofing Roof Diaphragm Evaluation
April 17, 2017
P a g e 4 | 4
LIMITATIONS:
The recommendations in this report are based on the review of the structural elements that were shown on
the available documents at the time of this report. No invasive testing or inspections were performed.
Martin/Martin, Inc. does not accept responsibility for the structural or material deficiencies not evident
during an observation of this type. No warranty, either express or implied, is given regarding any general or
specific conditions as they may affect Estes Park Swimming Pool Building. Except for the noted items above,
Martin/Martin, Inc. did not perform an in-depth review of the original structural design for code compliance.
Recommendations provided in this report are conceptual in nature and are not intended for construction.
We appreciate this opportunity to be of service. Please call if you have any questions regarding this report or
our recommendations.
Sincerely,
Edward Sabia, PE
Project Manager
Dwight Gilbert, PE
Engineer of Record
G:\PROJECTS\16.0117.S.02-Estes Park Community Center - Existing Building Re-Roofing Evaluation\Word Processing\16_0117S02_Apr_17_2017_R0_Rpt.docx
EF
4
TT
S
S
EF
5
EF
14
OSC
OSC
OSC
OSC
OSC
OSC
OSC
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EB
EC
ED
EE
EF
EG
EH
5
A307 6
A307
AX2112
1
3
4
4
AX302
1
AX301
2
AX301
AX2014
AX201
1
AX2024
AX202
1
1
AX302
2
AX303
1
AX303
3
AX302
2
AX302
3
AX303
W. TEAM LOCKERSW. TEAM LOCKERSW. TEAM LOCKERSW. TEAM LOCKERS
A106
FOYERFOYERFOYERFOYER
A101
EXIST POOL DECKEXIST POOL DECKEXIST POOL DECKEXIST POOL DECK
A109
M. SHOWERSM. SHOWERSM. SHOWERSM. SHOWERS
232
EXIST LAUNDRYEXIST LAUNDRYEXIST LAUNDRYEXIST LAUNDRY
A111
EXIST POOL MECHEXIST POOL MECHEXIST POOL MECHEXIST POOL MECH
A112
EXIST ELECEXIST ELECEXIST ELECEXIST ELEC
A113
EXIST POOL EQUIPEXIST POOL EQUIPEXIST POOL EQUIPEXIST POOL EQUIP
A114
EXIST CHEMEXIST CHEMEXIST CHEMEXIST CHEM
A115
EXIST NATATORIUMEXIST NATATORIUMEXIST NATATORIUMEXIST NATATORIUM
A110
POOL STORAGEPOOL STORAGEPOOL STORAGEPOOL STORAGE
A108
M. TEAM LOCKERM. TEAM LOCKERM. TEAM LOCKERM. TEAM LOCKER
A107
MECHANICALMECHANICALMECHANICALMECHANICAL
A102
STORAGESTORAGESTORAGESTORAGE
A105
M. LOCKERS 2M. LOCKERS 2M. LOCKERS 2M. LOCKERS 2
A103
VESTIBULEVESTIBULEVESTIBULEVESTIBULE
A104
POOL DECK ENTRYPOOL DECK ENTRYPOOL DECK ENTRYPOOL DECK ENTRY
A109A
XA110
A102
A103
A104B A104A
A108
232
289
WORK IN AREA WITHWORK IN AREA WITHWORK IN AREA WITHWORK IN AREA WITH
GRAY HATCH IS COVREDGRAY HATCH IS COVREDGRAY HATCH IS COVREDGRAY HATCH IS COVRED
UNDER THE EXXSITINGUNDER THE EXXSITINGUNDER THE EXXSITINGUNDER THE EXXSITING
SCOPE OF WORKSCOPE OF WORKSCOPE OF WORKSCOPE OF WORK
A111NA112NA114N
A115N
A113N
A105N
X115N
X114N
4,002 SF
EXIST POOL DECKEXIST POOL DECKEXIST POOL DECKEXIST POOL DECK
15 sf/occ
267267267267
599 SF
W. TEAM LOCKERSW. TEAM LOCKERSW. TEAM LOCKERSW. TEAM LOCKERS
50 sf/occ
13131313
249 SF
M. SHOWERSM. SHOWERSM. SHOWERSM. SHOWERS
50 sf/occ
5555
428 SF
EXIST POOL EQUIPEXIST POOL EQUIPEXIST POOL EQUIPEXIST POOL EQUIP
300 sf/occ
2222
346 SF
EXIST POOL MECHEXIST POOL MECHEXIST POOL MECHEXIST POOL MECH
300 sf/occ
2222
185 SF
EXIST LAUNDRYEXIST LAUNDRYEXIST LAUNDRYEXIST LAUNDRY
300 sf/occ
1111
178 SF
MECHANICALMECHANICALMECHANICALMECHANICAL
300 sf/occ
1111
509 SF
M. TEAM LOCKERM. TEAM LOCKERM. TEAM LOCKERM. TEAM LOCKER
50 sf/occ
11111111
595 SF
POOL STORAGEPOOL STORAGEPOOL STORAGEPOOL STORAGE
300 sf/occ
2222
473 SF
M. LOCKERS 2M. LOCKERS 2M. LOCKERS 2M. LOCKERS 2
50 sf/occ
10101010
5,078 SF
EXIST NATATORIUMEXIST NATATORIUMEXIST NATATORIUMEXIST NATATORIUM
50 sf/occ
102102102102
135 ft to Exit
(WATER AREA)(WATER AREA)(WATER AREA)(WATER AREA)
48 SF OPENING WITH48 SF OPENING WITH48 SF OPENING WITH48 SF OPENING WITH
90 MIN RATED FIRE DOOR90 MIN RATED FIRE DOOR90 MIN RATED FIRE DOOR90 MIN RATED FIRE DOOR
2222
11111111
13131313
208208208208
208208208208
16161616
2222 2222 1111
63 SF
STORAGESTORAGESTORAGESTORAGE
300 sf/occ
1111
98 ft to Exit
NEW EXIT DOORNEW EXIT DOORNEW EXIT DOORNEW EXIT DOOR
69" WIDE69" WIDE69" WIDE69" WIDE
CAPACITY 345CAPACITY 345CAPACITY 345CAPACITY 345
EXISTING EXIT DOOREXISTING EXIT DOOREXISTING EXIT DOOREXISTING EXIT DOOR
69" WIDE69" WIDE69" WIDE69" WIDE
CAPACITY 345CAPACITY 345CAPACITY 345CAPACITY 345
NEW 45 MIN RATED DOORSNEW 45 MIN RATED DOORSNEW 45 MIN RATED DOORSNEW 45 MIN RATED DOORS
NEW DOORNEW DOORNEW DOORNEW DOOR
NEW DOORNEW DOORNEW DOORNEW DOOR
NEW DOORNEW DOORNEW DOORNEW DOOR
SEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULE NEW DOORNEW DOORNEW DOORNEW DOOR
NEW DOORNEW DOORNEW DOORNEW DOOR
NEWNEWNEWNEW
DOORDOORDOORDOOR
POOL DECKPOOL DECKPOOL DECKPOOL DECK
EPOXYEPOXYEPOXYEPOXY
COATING TOCOATING TOCOATING TOCOATING TO
BE REPAIREDBE REPAIREDBE REPAIREDBE REPAIRED
POOL DECKPOOL DECKPOOL DECKPOOL DECK
EPOXYEPOXYEPOXYEPOXY
COATING TOCOATING TOCOATING TOCOATING TO
BE REPAIREDBE REPAIREDBE REPAIREDBE REPAIRED
POOL DECKPOOL DECKPOOL DECKPOOL DECK
EPOXYEPOXYEPOXYEPOXY
COATING TOCOATING TOCOATING TOCOATING TO
BE REPAIREDBE REPAIREDBE REPAIREDBE REPAIRED
WORK IN AREA WITHWORK IN AREA WITHWORK IN AREA WITHWORK IN AREA WITH
GRAY HATCH IS COVREDGRAY HATCH IS COVREDGRAY HATCH IS COVREDGRAY HATCH IS COVRED
UNDER THE EXXSITINGUNDER THE EXXSITINGUNDER THE EXXSITINGUNDER THE EXXSITING
SCOPE OF WORKSCOPE OF WORKSCOPE OF WORKSCOPE OF WORK
CEILING FAN CF-4 ASCEILING FAN CF-4 ASCEILING FAN CF-4 ASCEILING FAN CF-4 AS
DESCRIBED IN ORIGINALDESCRIBED IN ORIGINALDESCRIBED IN ORIGINALDESCRIBED IN ORIGINAL
SCOPE OF WORKSCOPE OF WORKSCOPE OF WORKSCOPE OF WORK
CEILING FAN CF-5 ASCEILING FAN CF-5 ASCEILING FAN CF-5 ASCEILING FAN CF-5 AS
DESCRIBED IN ORIGINALDESCRIBED IN ORIGINALDESCRIBED IN ORIGINALDESCRIBED IN ORIGINAL
SCOPE OF WORKSCOPE OF WORKSCOPE OF WORKSCOPE OF WORK
NEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORK
NEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORK
REFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMS
NEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORK
REFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMSREFINISH ALL GLULAM BEAMS
NEW LEDNEW LEDNEW LEDNEW LED
LIGHTS REF:LIGHTS REF:LIGHTS REF:LIGHTS REF:
ELECTRICALELECTRICALELECTRICALELECTRICAL
NEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORKNEW PAINT ON DUCTWORK
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
1/8" = 1'-0"
4/
1
7
/
2
0
1
7
4
:
5
1
:
4
0
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
FLOOR PLAN AND
RCP
AX101
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/8" = 1'-0"1 AQUATIC CENTER RENOVATION - FLOOR PLAN
1/8" = 1'-0"2 AQUATICS CENTER RENOVATION - CEILING PLAN
DOOR SCHEDULE- AQ CENTER
DOOR
NUMBER
DOOR FRAME
FINISH
FIRE
RATING
HDW
GROUP REMARKSTYPE
MATERI
AL FINISH
SIZE
TYPE
MATERI
ALTHK WIDTH HEIGHT
EXISTING FFE
A105N F AL FF 1 3/4" 72" 84" B AL FF STORAGE LOCKSET, GROUP TBD
A111N F AL FF 1 3/4" 72" 84" B AL FF STORAGE LOCKSET, GROUP TBD
A112N F AL FF 1 3/4" 72" 84" B AL FF STORAGE LOCKSET, GROUP TBD
A113N E AL FF 1 3/4" 24" 84" B AL FF STORAGE LOCKSET, GROUP TBD
A114N F AL FF 1 3/4" 72" 84" B AL FF STORAGE LOCKSET, GROUP TBD
A115N E AL FF 1 3/4" 24" 84" B AL FF STORAGE LOCKSET, GROUP TBD
X114N A HM PT05 1 3/4" 36" 84" B HM PT05 45 MIN 33
X115N A HM PT05 1 3/4" 30" 84" B HM PT05 45 MIN 32
IBC NOTE: EGRESS PATHS
AND CAPACITY HAVE NOT
CHANGED MATERIALLY
FROM THE PERMIT SET, BUT
HAVE BEEN RE-STUDIED AND
ARE REPEATED HERE FOR
THOROUGHNESS
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EB
EC
ED
EE
EF
EG
EH
NJ
5
A307 6
A307
4
AX302
1
AX301
2
AX301
AX2014
AX201
1
AX2024
1
AX302
2
AX303
1
AX303
3
AX302
2
AX302
3
AX303
2
2 2
2
1
1
3
3
4
2
2
3
3
5
5
5
5
5
7
9
6
6
6
8
10
8101/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"
1/
2
"
/
1
2
"
1/
2
"
/
1
2
"
1/
2
"
/
1
2
"
1/
2
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
1/
4
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12" / 12"12" / 12"12" / 12"12" / 12"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
12
"
/
1
2
"
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
EB
EC
ED
EE
EF
EG
EH
NJ
2
2 2
2
1
1
3
3
4
2
2
3
3
5
5
5
5
5
7
9
7
7
6
8
6
8
1. EXISTING FLAT ROOF.
DEMOLISH EXISTING MEMBRANE/BALLASTED SYSTEM,
INSULATION, TERMANTIONS AND FLASHING. INSPECT SUBSTRATE
(3X4 DECKING) AND REPAIR/REPLACE AS NECESSARY.
2. EXISTING FLAT ROOF.
DEMOLISH EXISTING MEMBRANE/BALLASTED SYSTEM,
INSULATION, TERMINANTIONS AND FLASHING. INSPECT PLYWOOD
SUBSTRATE AND REPAIR/REPLACE AS NECESSARY.
3. EXISTING STANDING SEAM METAL ROOF TO REMAIN.
4. EXISTING KAL WALL
SYSTEM TO REMAIN --GLAZING TO BE REMOVED. ANY ALTERATION OR
DEMOLITION OF KALWALL FASHIGN TO BE COODINATE D WITH MFR OF
ADJACENT ROOF REPLACEMENT SYSTEM.
5. EXISTING EIFS PARAPET
DEMOLISH EIFS. INSPECT UNDERLYING PLYWOOD AND /OR EXTERIOR
GYPSUM SUBSTRATES AND REPLACE WHEN DETERIORATED. D
6. ROOF DRAINS
DRAINS TO REMAIN. INSPECT DRAIN SYSTEM FOR
LEAKS AND REPAIR PRIOR TO ROOF REPLACEMENT.
7. SKYLIGHTS.
DEMOLISH EXISTING SKYLIGHTS, CURBS AND FLASHING. PYRAMID
SKYLIGHT DEMOLITION IN ORIGINAL SCOPE OF WORK
8. ROOF HATCH AND LADDERS.
DEMOLISH ROOF HATCH. NORTHERN LADDER TO BE RELOCATED.
9. HVAC SYSTEMS.
UNITS AND PIPING DEMOLISHED PER MD105 - NO NEW WORK.
1. EPDM ROOF.
ROOF REPLACEMENT AS FOLLOWS:
•FULLY ADHERED EPDM MEMBRANE, FLASHING AND ACCESSORIES PER
SPEC 07 5323
•5 INCHES POLYISO INSULATION*
•VAPOR BARRIER PER SPEC 07 5323 OR FIRESTONE V-FORCE
* R30 REQUIRED. FOR INSULATION INDICATING LESS THAN R6/INCH,
INCREASE SIZE OF ANY LAYER BY AMOUNT REQUIRED TO MEET CODE
EXISTING DECK REINFORCEMENT RE: STRUCTURAL
2. EPDM ROOF.
ROOF REPLACEMENT AS DESCRIBED ABOVE.
3. METAL ROOF RETROFIT
ROOF RETROFIT AS FOLLOWS:
•SIKA DECOR PROFILES
•SIKA DECOR ADHERED PVC MEMBRANE - SPEC 07 5419
•SIKA METAL RETROFIT APPROVED COVERBOARD
•SIKA METAL RETROFIT APPROVED INSULATION BETWEEN EXISTING 'SEAMS"
FASTENERS, FLASHING AND ACCESSORIES PER SIKA RETROFIT/DECOR
4. NEW KALWALL GLAZING AND SEALANT PER KALWALL.
5. FORMER EIFS PARAPETS.
PROVIDE METAL COPING, ANCHOR AND NAILER AS DESCRIBED IN DETAILS.
6. ROOF DRAINS
EXTEND LEADERS AS NECESSARY TO ACCOMODATE INCREASED ROOF
THICKNESS. FLASH PER EPDM ROOFING MFR.
7. SKYLIGHTS.
REPLACE EXISTING SKYLIGHTS WITH FIXED GLAZING OF SIMILAR
DIMENSIONS. REBUILD CURB AS NECESSARY AND FLASH PER METAL
RETROFIT INSTRUCTIONS.
8. ROOF HATCH AND LADDERS.
PROVIDE NEW ROOF HATCH AND LADDER, SPEC 07 7200.
RELOCATE EXISTING LADDER TO NORTH WALL.
9. HVAC SYSTEMS.
NEW UNITS AND PIPING IN ORIGINAL SCOPE OF WORK. SEE M SHEETS.
FLASHING PER EPDM ROOF MFR.
10. ROOF WALKWAY PADS
PROVIDE NEW ROOF WALKWAY PADS PER SPEC 07 5323
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
As indicated
4/
1
7
/
2
0
1
7
4
:
5
1
:
4
5
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION - ROOF
PLAN
AX102
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/8" = 1'-0"1 ROOF REPLACEMENT PLAN
1/8" = 1'-0"2 ROOF DEMOLITION PLAN
1/2" = 1'-0"
ROOF DEMOLITION NOTES
1/2" = 1'-0"
ROOF REPLACEMENT NOTES
EAEBECEDEEEF
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EGEHNJ
22' - 6"22' - 6"22' - 6"22' - 6"
T.O. CMUT.O. CMUT.O. CMUT.O. CMU
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
480 SQ FT480 SQ FT480 SQ FT480 SQ FT
EIFS ON CMUEIFS ON CMUEIFS ON CMUEIFS ON CMU
104 SQ FT104 SQ FT104 SQ FT104 SQ FT
EIFS ON CMUEIFS ON CMUEIFS ON CMUEIFS ON CMU
104 SQ FT104 SQ FT104 SQ FT104 SQ FT
13' - 4"13' - 4"13' - 4"13' - 4"
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
16 SF - SEE NOTE 116 SF - SEE NOTE 116 SF - SEE NOTE 116 SF - SEE NOTE 1
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
60 SQ FT60 SQ FT60 SQ FT60 SQ FT
10'-0"10'-0"10'-0"10'-0"7'-10"7'-10"7'-10"7'-10"22'-6"22'-6"22'-6"22'-6"9'-8"9'-8"9'-8"9'-8"9'-8"9'-8"9'-8"9'-8"22'-6"22'-6"22'-6"22'-6"17'-8 3/8"17'-8 3/8"17'-8 3/8"17'-8 3/8"
METAL ROOF 422 SFMETAL ROOF 422 SFMETAL ROOF 422 SFMETAL ROOF 422 SF
EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
B.O.D.
20' - 10"
UPPER LEVEL
0' - 0"
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
17' - 4"17' - 4"17' - 4"17' - 4"
EIFS ON CMUEIFS ON CMUEIFS ON CMUEIFS ON CMU
754 SQ FT 754 SQ FT 754 SQ FT 754 SQ FT
EIFS ON STUDEIFS ON STUDEIFS ON STUDEIFS ON STUD
458 SQ FT 458 SQ FT 458 SQ FT 458 SQ FT
T.O. CMUT.O. CMUT.O. CMUT.O. CMU
7'-10"7'-10"7'-10"7'-10" 5'-8"5'-8"5'-8"5'-8"28'-0"28'-0"28'-0"28'-0"10'-2"10'-2"10'-2"10'-2" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 11'-0"11'-0"11'-0"11'-0" 10'-9 5/8"10'-9 5/8"10'-9 5/8"10'-9 5/8"
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
47 SQ FT47 SQ FT47 SQ FT47 SQ FT
EIFS ON STUDEIFS ON STUDEIFS ON STUDEIFS ON STUD
15 SQ FT15 SQ FT15 SQ FT15 SQ FT
METAL ROOF 1592 SQ FTMETAL ROOF 1592 SQ FTMETAL ROOF 1592 SQ FTMETAL ROOF 1592 SQ FT
METAL ROOF 1156 SQ FTMETAL ROOF 1156 SQ FTMETAL ROOF 1156 SQ FTMETAL ROOF 1156 SQ FT
EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -
EIFS PARAPETEIFS PARAPETEIFS PARAPETEIFS PARAPET
B.O.D.
20' - 10"
UPPER LEVEL
0' - 0"
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"B.O.D.
20' - 10"
1111
2222
2222 1111
6666
5555
6666
1111
5555
3333
4444
EAEBECEDEEEF
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
EGEH
3333
55556666
3333
2222
5555
2222 2222
4444
5555
5555
1111
2222
PAINT ON 6.25" SMOOTH CEMENT SIDING -
SHERWIN WILLIAMS 6118 LEATHER BOUND*
PAINT ON 6.25" SMOOTH CEMENT SIDING -
SHERWIN WILLIAMS 7730 FOREST WOOD*
PAINT ON 5.5" 4/4 SMOOTH CEMENT TRIM -
SHERWIN WILLIAMS 6118 LEATHER BOUND
PAINT ON 5.5" 4/4 SMOOTH CEMENT TRIM -
SHERWIN WILLIAMS 7730 FOREST WOOD
PRE-FINISHED METAL COPING -
ARCHITECT TO SELECT COLOR FROM MFR'S
STANDARD RANGE
SIKA 'DECOR' PVC ROOF - LEAD GRAY
MASONRY VENEER BLOCK -
COLOR TO MATCH EXISTING
*AT OUTSIDE CORNERS OF SIDING, PROVIDE
METAL TRIM (EZ .31 OR SIM) SEE 1/A403 IN
BASE SET
1
2
3
4
5
6
7
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-24-17 BULLETIN 010
4/24/2017
As indicated
5/
3
/
2
0
1
7
9
:
1
0
:
4
3
A
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
ELEVATIONS
AX201
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/8" = 1'-0"3 AQ CENTER WEST ELEVATION - DEMO
1/8" = 1'-0"2 AQ CENTER SOUTH ELEVATION - DEMO
1/8" = 1'-0"1 AQ CENTER SOUTH ELEVATION - NEW
1/8" = 1'-0"4 AQ CENTER WEST ELEVATION - NEW
1" = 1'-0"
AQUATIC CENTER RENOVATION MATERIALS LEGEND
EA EB EC ED EE EF
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
EG EH NJ
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
857 SQ FT857 SQ FT857 SQ FT857 SQ FT
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
33 SQ FT33 SQ FT33 SQ FT33 SQ FT
SEE NOTE 1SEE NOTE 1SEE NOTE 1SEE NOTE 1
10'-0"10'-0"10'-0"10'-0" 7'-10"7'-10"7'-10"7'-10"22'-6"22'-6"22'-6"22'-6"9'-8"9'-8"9'-8"9'-8" 9'-8"9'-8"9'-8"9'-8"22'-6"22'-6"22'-6"22'-6"17'-8 3/8"17'-8 3/8"17'-8 3/8"17'-8 3/8"
EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -EIFS PARAPETS -
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
60 SQ FT60 SQ FT60 SQ FT60 SQ FT
B.O.D.
20' - 10"
UPPER LEVEL
0' - 0"
E1E2E3E4E5E6E7E8E9E10E11E12E13E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
METAL ROOFMETAL ROOFMETAL ROOFMETAL ROOF
1588 SF1588 SF1588 SF1588 SF
EIFS ON STUDEIFS ON STUDEIFS ON STUDEIFS ON STUD
1756 SQ FT1756 SQ FT1756 SQ FT1756 SQ FT
EIFS ON CMUEIFS ON CMUEIFS ON CMUEIFS ON CMU
68 SQ FT68 SQ FT68 SQ FT68 SQ FT
7'-10"7'-10"7'-10"7'-10"5'-8"5'-8"5'-8"5'-8"28'-0"28'-0"28'-0"28'-0"10'-2"10'-2"10'-2"10'-2"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"11'-0"10'-9 5/8"10'-9 5/8"10'-9 5/8"10'-9 5/8"
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
16 SQ FT - SEE NOTE 116 SQ FT - SEE NOTE 116 SQ FT - SEE NOTE 116 SQ FT - SEE NOTE 1
EIFS ON STUDSEIFS ON STUDSEIFS ON STUDSEIFS ON STUDS
60 SQ FT EA60 SQ FT EA60 SQ FT EA60 SQ FT EA
EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -EIFS PARAPET -
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EFIS PARAPETEFIS PARAPETEFIS PARAPETEFIS PARAPET
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EIFS PARAPETEIFS PARAPETEIFS PARAPETEIFS PARAPET
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
EIFS PARAPETEIFS PARAPETEIFS PARAPETEIFS PARAPET
SEE NOTE 2SEE NOTE 2SEE NOTE 2SEE NOTE 2
B.O.D.
20' - 10"
UPPER LEVEL
0' - 0"
EA EB EC ED EE EF
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
EG EH
3333
5555
3333
2222
1111
5555
5555
1111
6666
1111
7777
UPPER LEVEL
0' - 0"
E1E2E3E4E5E6E7E8E9E10E11E12E13E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
4444
2222
3333
1111
5555
2222
5555
6666
5555
1111
2222 2222
PAINT ON 6.25" SMOOTH CEMENT SIDING -
SHERWIN WILLIAMS 6118 LEATHER BOUND*
PAINT ON 6.25" SMOOTH CEMENT SIDING -
SHERWIN WILLIAMS 7730 FOREST WOOD*
PAINT ON 5.5" 4/4 SMOOTH CEMENT TRIM -
SHERWIN WILLIAMS 6118 LEATHER BOUND
PAINT ON 5.5" 4/4 SMOOTH CEMENT TRIM -
SHERWIN WILLIAMS 7730 FOREST WOOD
PRE-FINISHED METAL COPING -
ARCHITECT TO SELECT COLOR FROM MFR'S
STANDARD RANGE
SIKA 'DECOR' PVC ROOF - LEAD GRAY
MASONRY VENEER BLOCK -
COLOR TO MATCH EXISTING
*AT OUTSIDE CORNERS OF SIDING, PROVIDE
METAL TRIM (EZ .31 OR SIM) SEE 1/A403 IN
BASE SET
1
2
3
4
5
6
7
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
As indicated
4/
1
7
/
2
0
1
7
4
:
5
1
:
5
7
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
ELEVATIONS
AX202
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/8" = 1'-0"3 AQ CENTER EAST ELEVATION - DEMO
1/8" = 1'-0"2 AQ CENTER NORTH ELEVATION - DEMO
1/8" = 1'-0"4 AQ CENTER EAST ELEVATION - NEW
1/8" = 1'-0"1 AQ CENTER NORTH ELEVATION - NEW
1" = 1'-0"
AQUATIC CENTER RENOVATION MATERIALS LEGEND
8' - 8"8' - 8"8' - 8"8' - 8"
12' - 9 1/2"12' - 9 1/2"12' - 9 1/2"12' - 9 1/2"
NEW SCORE FACE CMUNEW SCORE FACE CMUNEW SCORE FACE CMUNEW SCORE FACE CMU
IN ORIGINAL SCOPEIN ORIGINAL SCOPEIN ORIGINAL SCOPEIN ORIGINAL SCOPE
EXISTING SCORING PLATFORMEXISTING SCORING PLATFORMEXISTING SCORING PLATFORMEXISTING SCORING PLATFORM
13' - 4"13' - 4"13' - 4"13' - 4"
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
A114N A112N A111N
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
NEW ACOUSTICNEW ACOUSTICNEW ACOUSTICNEW ACOUSTIC
PANELSPANELSPANELSPANELS
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING 1X6 PLANKSEXISTING 1X6 PLANKSEXISTING 1X6 PLANKSEXISTING 1X6 PLANKS
NO WORKNO WORKNO WORKNO WORK
EXISTING BLEACHERSEXISTING BLEACHERSEXISTING BLEACHERSEXISTING BLEACHERS
REFINISHREFINISHREFINISHREFINISH
EXISTING BLEACHERSEXISTING BLEACHERSEXISTING BLEACHERSEXISTING BLEACHERS
REFINISHREFINISHREFINISHREFINISH
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
EXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMUEXISTING SCORE FACE CMU
NO WORKNO WORKNO WORKNO WORK
EXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORKEXISTING DUCTWORK
NEW PAINTNEW PAINTNEW PAINTNEW PAINT
EXISTING GLULAMEXISTING GLULAMEXISTING GLULAMEXISTING GLULAM
REFINISHREFINISHREFINISHREFINISH
NEW/ RE-BUILT CMU MECHANICAL ENCLOSURENEW/ RE-BUILT CMU MECHANICAL ENCLOSURENEW/ RE-BUILT CMU MECHANICAL ENCLOSURENEW/ RE-BUILT CMU MECHANICAL ENCLOSURE
IN ORIGNAL SCOPE OF WORKIN ORIGNAL SCOPE OF WORKIN ORIGNAL SCOPE OF WORKIN ORIGNAL SCOPE OF WORK
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
A108
NEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELSNEW ACOUSTIC PANELS
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
1/4" = 1'-0"
4/
1
7
/
2
0
1
7
4
:
5
2
:
0
1
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
INTERIOR
ELEVATIONS
AX211
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/4" = 1'-0"4 INTERIOR - NORTH
1/4" = 1'-0"2 INTERIOR - WEST
1/4" = 1'-0"1 INTERIOR - SOUTH
1/4" = 1'-0"3 INTERIOR - EAST
EBEC
EDEE
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
T.O.S
22' - 6"
B.O.D.
20' - 10"
AX301
4
AX301
3
8' - 8"8' - 8"8' - 8"8' - 8"
WALL TYPE AWALL TYPE AWALL TYPE AWALL TYPE A
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFR
3.3.3.3.1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*
5.5.5.5.EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)
6.6.6.6.EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*
7.7.7.7.EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*
8.8.8.8.INTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTED
* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED
U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4
AX302
5
Sim
17' - 4"17' - 4"17' - 4"17' - 4"
EX. 1X 6 PLANKS TO REMAINEX. 1X 6 PLANKS TO REMAINEX. 1X 6 PLANKS TO REMAINEX. 1X 6 PLANKS TO REMAIN
EX. SOFFIT CONSTRUCTIONEX. SOFFIT CONSTRUCTIONEX. SOFFIT CONSTRUCTIONEX. SOFFIT CONSTRUCTION
EX BLOCK AND SILL TO REMAINEX BLOCK AND SILL TO REMAINEX BLOCK AND SILL TO REMAINEX BLOCK AND SILL TO REMAIN
SKYLIGHT TO BE REPLACED WITHSKYLIGHT TO BE REPLACED WITHSKYLIGHT TO BE REPLACED WITHSKYLIGHT TO BE REPLACED WITH
FIXED UNIT - COORD CURB DETAILFIXED UNIT - COORD CURB DETAILFIXED UNIT - COORD CURB DETAILFIXED UNIT - COORD CURB DETAIL
WITH ROOF MFR AND SKYLIGHT MFRWITH ROOF MFR AND SKYLIGHT MFRWITH ROOF MFR AND SKYLIGHT MFRWITH ROOF MFR AND SKYLIGHT MFR
EX. WINDOW TO REMAIN.EX. WINDOW TO REMAIN.EX. WINDOW TO REMAIN.EX. WINDOW TO REMAIN.
PROVIDE NEW SEALANT ATPROVIDE NEW SEALANT ATPROVIDE NEW SEALANT ATPROVIDE NEW SEALANT AT
PERIMETER, TYP.PERIMETER, TYP.PERIMETER, TYP.PERIMETER, TYP.
KAL-WALL - GLAZING REPLACEMENT ONLYKAL-WALL - GLAZING REPLACEMENT ONLYKAL-WALL - GLAZING REPLACEMENT ONLYKAL-WALL - GLAZING REPLACEMENT ONLY
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
EX. 2X12 RAFTERS TO REMAINEX. 2X12 RAFTERS TO REMAINEX. 2X12 RAFTERS TO REMAINEX. 2X12 RAFTERS TO REMAIN
COORDINATE DETAIL WITH KAL-WALL MFRCOORDINATE DETAIL WITH KAL-WALL MFRCOORDINATE DETAIL WITH KAL-WALL MFRCOORDINATE DETAIL WITH KAL-WALL MFR
1X6 WOOD PLANKS TO REMAIN1X6 WOOD PLANKS TO REMAIN1X6 WOOD PLANKS TO REMAIN1X6 WOOD PLANKS TO REMAIN
UPPER LEVEL
0' - 0"
E1
E2
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
T.O.S
22' - 6"
B.O.D.
20' - 10"
AX301
6
AX301
5
AX302
5
Sim
WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFR
3.3.3.3.1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*
5.5.5.5.EX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATT
6.6.6.6.EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*
7.7.7.7.EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*
8.8.8.8.INTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTED
* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED
U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4
WALL TYPE AWALL TYPE AWALL TYPE AWALL TYPE A
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
EX. CMU ANDEX. CMU ANDEX. CMU ANDEX. CMU AND
BLOCK WALL TOBLOCK WALL TOBLOCK WALL TOBLOCK WALL TO
REMAINREMAINREMAINREMAIN
17' - 4"17' - 4"17' - 4"17' - 4"
AX301
3
Sim
PROVIDE NEW MEMBRANE FLASHINGPROVIDE NEW MEMBRANE FLASHINGPROVIDE NEW MEMBRANE FLASHINGPROVIDE NEW MEMBRANE FLASHING
WHERE STUCCO ISI REMOVED FROMWHERE STUCCO ISI REMOVED FROMWHERE STUCCO ISI REMOVED FROMWHERE STUCCO ISI REMOVED FROM
PARAPET - COORIDNATE FLASHINGPARAPET - COORIDNATE FLASHINGPARAPET - COORIDNATE FLASHINGPARAPET - COORIDNATE FLASHING
DETAIL WITH KAL WALL MFRDETAIL WITH KAL WALL MFRDETAIL WITH KAL WALL MFRDETAIL WITH KAL WALL MFR
NEW KEFED ACOUSTIC PANELNEW KEFED ACOUSTIC PANELNEW KEFED ACOUSTIC PANELNEW KEFED ACOUSTIC PANEL
EX. GLULAMEX. GLULAMEX. GLULAMEX. GLULAM
ED
T.O.S
22' - 6"
B.O.D.
20' - 10"
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1
DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.
PROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAIL
PROVIDE NEW 1-1/2" RIGIDPROVIDE NEW 1-1/2" RIGIDPROVIDE NEW 1-1/2" RIGIDPROVIDE NEW 1-1/2" RIGID
INSULATION HERE AND WRAPINSULATION HERE AND WRAPINSULATION HERE AND WRAPINSULATION HERE AND WRAP
EPDM MEBRANE OVER PARAPETEPDM MEBRANE OVER PARAPETEPDM MEBRANE OVER PARAPETEPDM MEBRANE OVER PARAPET
FIRESTONE T-7FIRESTONE T-7FIRESTONE T-7FIRESTONE T-7
PROVIDE COUNTERFLASHING ANDPROVIDE COUNTERFLASHING ANDPROVIDE COUNTERFLASHING ANDPROVIDE COUNTERFLASHING AND
TERMINATION PER T-7 DETAIL -TERMINATION PER T-7 DETAIL -TERMINATION PER T-7 DETAIL -TERMINATION PER T-7 DETAIL -
MODIFY AS REQUIREDMODIFY AS REQUIREDMODIFY AS REQUIREDMODIFY AS REQUIRED
SIKA DS1-9SIKA DS1-9SIKA DS1-9SIKA DS1-9
ROOFING CONTRACTOR TO WORKROOFING CONTRACTOR TO WORKROOFING CONTRACTOR TO WORKROOFING CONTRACTOR TO WORK
WITH ARCHITECT TO MODIFY THISWITH ARCHITECT TO MODIFY THISWITH ARCHITECT TO MODIFY THISWITH ARCHITECT TO MODIFY THIS
DETAIL FOR VERITCAL APPLICATIONDETAIL FOR VERITCAL APPLICATIONDETAIL FOR VERITCAL APPLICATIONDETAIL FOR VERITCAL APPLICATION
EC
B.O.D.
20' - 10"
TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.
CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.
SIKA 3-4SIKA 3-4SIKA 3-4SIKA 3-4
PROVIDE TERMINATION BAR ANDPROVIDE TERMINATION BAR ANDPROVIDE TERMINATION BAR ANDPROVIDE TERMINATION BAR AND
SEALANT PER 3-4 DETAILSEALANT PER 3-4 DETAILSEALANT PER 3-4 DETAILSEALANT PER 3-4 DETAIL
PROVIDE FLASHING, SECUREMENTPROVIDE FLASHING, SECUREMENTPROVIDE FLASHING, SECUREMENTPROVIDE FLASHING, SECUREMENT
AND WELD PER 3-4 DETAILAND WELD PER 3-4 DETAILAND WELD PER 3-4 DETAILAND WELD PER 3-4 DETAIL
FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
CI GIRT AND FASTENERSCI GIRT AND FASTENERSCI GIRT AND FASTENERSCI GIRT AND FASTENERS
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
GALV. MTL Z- FLASHINGGALV. MTL Z- FLASHINGGALV. MTL Z- FLASHINGGALV. MTL Z- FLASHING
EX. 2X12 RAFTERSEX. 2X12 RAFTERSEX. 2X12 RAFTERSEX. 2X12 RAFTERS
E2
CEMENT SIDING ANDCEMENT SIDING ANDCEMENT SIDING ANDCEMENT SIDING AND
STARTER STRIPSTARTER STRIPSTARTER STRIPSTARTER STRIP
CEMENT TRIM BOARD ATCEMENT TRIM BOARD ATCEMENT TRIM BOARD ATCEMENT TRIM BOARD AT
PERIMETERPERIMETERPERIMETERPERIMETER
GALV. MTL Z-FLASHING,GALV. MTL Z-FLASHING,GALV. MTL Z-FLASHING,GALV. MTL Z-FLASHING,
SECURED TO CHANNELSECURED TO CHANNELSECURED TO CHANNELSECURED TO CHANNEL
MORE FLASHING TAPEMORE FLASHING TAPEMORE FLASHING TAPEMORE FLASHING TAPE
OVERLAPS HEAD FLASHINGOVERLAPS HEAD FLASHINGOVERLAPS HEAD FLASHINGOVERLAPS HEAD FLASHING
GALV. MTL Z-FLASHINGGALV. MTL Z-FLASHINGGALV. MTL Z-FLASHINGGALV. MTL Z-FLASHING
FLASHING TAPE WRAPSFLASHING TAPE WRAPSFLASHING TAPE WRAPSFLASHING TAPE WRAPS
INTO OPENINGINTO OPENINGINTO OPENINGINTO OPENING
NEW 2X2 CONT STEEL ANGLE -NEW 2X2 CONT STEEL ANGLE -NEW 2X2 CONT STEEL ANGLE -NEW 2X2 CONT STEEL ANGLE -
FASTEN TO FRAMINGFASTEN TO FRAMINGFASTEN TO FRAMINGFASTEN TO FRAMING
GALV. MTL JAMBGALV. MTL JAMBGALV. MTL JAMBGALV. MTL JAMB
FLASHING, PAINTFLASHING, PAINTFLASHING, PAINTFLASHING, PAINT
EX. 2X6 HEADEREX. 2X6 HEADEREX. 2X6 HEADEREX. 2X6 HEADER
CONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTION
EXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDE
NEW SEALANT AT PERIMETER.NEW SEALANT AT PERIMETER.NEW SEALANT AT PERIMETER.NEW SEALANT AT PERIMETER.
NOTE: USE THIS DETAIL FOR TWO UPPERNOTE: USE THIS DETAIL FOR TWO UPPERNOTE: USE THIS DETAIL FOR TWO UPPERNOTE: USE THIS DETAIL FOR TWO UPPER
SIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOW
E2
T.O.S
22' - 6"
NEW GALV. MTL SILL FLASHINGNEW GALV. MTL SILL FLASHINGNEW GALV. MTL SILL FLASHINGNEW GALV. MTL SILL FLASHING
EXTENSION WITH DRIP EDGEEXTENSION WITH DRIP EDGEEXTENSION WITH DRIP EDGEEXTENSION WITH DRIP EDGE
FLASHING TAPE WRAPS INTOFLASHING TAPE WRAPS INTOFLASHING TAPE WRAPS INTOFLASHING TAPE WRAPS INTO
OPENINGOPENINGOPENINGOPENING
NEW 2X2 STEEL ANGLE ATNEW 2X2 STEEL ANGLE ATNEW 2X2 STEEL ANGLE ATNEW 2X2 STEEL ANGLE AT
PERIMETER, FASTEN TO FAMINGPERIMETER, FASTEN TO FAMINGPERIMETER, FASTEN TO FAMINGPERIMETER, FASTEN TO FAMING
CEMENT TRIM BOARD ATCEMENT TRIM BOARD ATCEMENT TRIM BOARD ATCEMENT TRIM BOARD AT
PERIMETERPERIMETERPERIMETERPERIMETER
EX. 2X6 SILLEX. 2X6 SILLEX. 2X6 SILLEX. 2X6 SILL
CONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTION
EXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDEEXISTING WINDOW. PROVIDE
NEW SELANT AT PERIMETER.NEW SELANT AT PERIMETER.NEW SELANT AT PERIMETER.NEW SELANT AT PERIMETER.
NOTE: USE THIS DETAIL FOR TWO LOWERNOTE: USE THIS DETAIL FOR TWO LOWERNOTE: USE THIS DETAIL FOR TWO LOWERNOTE: USE THIS DETAIL FOR TWO LOWER
SIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOWSIDES OF DIAMOND GABLE WINDOW
CEMENT SIDING - LEAVE 1/4"CEMENT SIDING - LEAVE 1/4"CEMENT SIDING - LEAVE 1/4"CEMENT SIDING - LEAVE 1/4"
GAP AND CAULKGAP AND CAULKGAP AND CAULKGAP AND CAULK
EX. 1X BOARD PANELINGEX. 1X BOARD PANELINGEX. 1X BOARD PANELINGEX. 1X BOARD PANELING
TO REMAINTO REMAINTO REMAINTO REMAIN
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
As indicated
4/
1
7
/
2
0
1
7
4
:
5
2
:
0
4
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
SECTIONS AND
DETAILS
AX301
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/2" = 1'-0"1 Section @ GRID EB THRU EE
1/2" = 1'-0"2 Section @ GRID E1 & E2
1 1/2" = 1'-0"4 FLASHING @ ROOF TRANSITION
1 1/2" = 1'-0"3 FLASHING @ LOWER SLOPED ROOF
1 1/2" = 1'-0"6 WINDOW HEAD, TYP
1 1/2" = 1'-0"5 WINDOW SILL, TYP
DISCLAIMER:
DETAILS DEPICT CONDITIONS AS DESCRIBED
BY RECORD DRAWINGS AND MAY NOT
REFLECT ACTUAL AS-BUILT CONDITIONS.
CONTRACTORS TO TO VERIFY ALL
CONDITIONS IN FIELD.
UPPER LEVEL
0' - 0"
EC
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
T.O.S
22' - 6"
EX. INTERMITTENT FOOTINGEX. INTERMITTENT FOOTINGEX. INTERMITTENT FOOTINGEX. INTERMITTENT FOOTING
EX, GRADE BEAMEX, GRADE BEAMEX, GRADE BEAMEX, GRADE BEAM
AX302
7
B.O.D.
20' - 10"
EXIST POOL DECKEXIST POOL DECKEXIST POOL DECKEXIST POOL DECK
A109
WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFR
3.3.3.3.2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND
AIR BARRIERAIR BARRIERAIR BARRIERAIR BARRIER
4.4.4.4.EX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMU
U FACTOR = .064 PER ASHRAE 90.1 TABLES A3.1C&DU FACTOR = .064 PER ASHRAE 90.1 TABLES A3.1C&DU FACTOR = .064 PER ASHRAE 90.1 TABLES A3.1C&DU FACTOR = .064 PER ASHRAE 90.1 TABLES A3.1C&D
WALL CONSTRUCTION A @ PARAPETWALL CONSTRUCTION A @ PARAPETWALL CONSTRUCTION A @ PARAPETWALL CONSTRUCTION A @ PARAPET
AX302
5
Sim
UPPER LEVEL
0' - 0"
E2
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
T.O.S
22' - 6"
B.O.D.
20' - 10"
AX302
5
Sim
13' - 4"13' - 4"13' - 4"13' - 4"
NEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELS
WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16" OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16" OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16" OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16" OC, FASTENED TO CMU PER MFR
3.3.3.3.2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND2" POLYISO INSULATION, SEAMS TAPED FOR WATER AND
AIR BARRIERAIR BARRIERAIR BARRIERAIR BARRIER
4.4.4.4.EX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMU
5.5.5.5.U-FACTOR = .064 PER ASHRAE 90-1TABLES A3.1C&DU-FACTOR = .064 PER ASHRAE 90-1TABLES A3.1C&DU-FACTOR = .064 PER ASHRAE 90-1TABLES A3.1C&DU-FACTOR = .064 PER ASHRAE 90-1TABLES A3.1C&D
FIBER CEMENT DETAIL ATFIBER CEMENT DETAIL ATFIBER CEMENT DETAIL ATFIBER CEMENT DETAIL AT
EXISTING PENTRATIONS PEREXISTING PENTRATIONS PEREXISTING PENTRATIONS PEREXISTING PENTRATIONS PER
SIDING MFRSIDING MFRSIDING MFRSIDING MFR
AX302
7
Sim
AX303
5
WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFR
3.3.3.3.1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*
5.5.5.5.EX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATT
6.6.6.6.EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*
7.7.7.7.EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*
8.8.8.8.INTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTED
* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED
U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4
UPPER LEVEL
0' - 0"
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
T.O.S
22' - 6"
EG
EXISTNG GLULAMEXISTNG GLULAMEXISTNG GLULAMEXISTNG GLULAM
INFILL CMU WALL (IN BASEINFILL CMU WALL (IN BASEINFILL CMU WALL (IN BASEINFILL CMU WALL (IN BASE
SCOPE OF WORK)SCOPE OF WORK)SCOPE OF WORK)SCOPE OF WORK)
EX. 2X12 JOISTS, LVLEX. 2X12 JOISTS, LVLEX. 2X12 JOISTS, LVLEX. 2X12 JOISTS, LVL
SISTERED REF. STRUCTURALSISTERED REF. STRUCTURALSISTERED REF. STRUCTURALSISTERED REF. STRUCTURAL
ROOF TYPE 1ROOF TYPE 1ROOF TYPE 1ROOF TYPE 1
TERMINATE CLADDING HERE,TERMINATE CLADDING HERE,TERMINATE CLADDING HERE,TERMINATE CLADDING HERE,
INSULAITON CONTINUESINSULAITON CONTINUESINSULAITON CONTINUESINSULAITON CONTINUES
AX302
5
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
AX302
6
NEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELSNEW KERFED ACOUSTIC PANELS
AX302
8
Sim
WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFR
3.3.3.3.1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*
5.5.5.5.EX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATTEX. 2X6 STUDS, 16" OC (VIF) W/ R-11 BATT
6.6.6.6.EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*
7.7.7.7.EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*
8.8.8.8.INTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTEDINTERIOR FINSH AS NOTED
* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED
U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4U FACTOR = .050 PER ASHRAE 90-1 TABLE A3.4
EC
CI GIRTCI GIRTCI GIRTCI GIRT
WATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER AT
TAPED INSULATION SEAMSTAPED INSULATION SEAMSTAPED INSULATION SEAMSTAPED INSULATION SEAMS
MIN CLEARANCE 6" ABOVEMIN CLEARANCE 6" ABOVEMIN CLEARANCE 6" ABOVEMIN CLEARANCE 6" ABOVE
GRADE - 2" ABOVE HARDSCAPEGRADE - 2" ABOVE HARDSCAPEGRADE - 2" ABOVE HARDSCAPEGRADE - 2" ABOVE HARDSCAPE
FLASHING TAPE TOFLASHING TAPE TOFLASHING TAPE TOFLASHING TAPE TO
OVERLAP MTL FLASHINGOVERLAP MTL FLASHINGOVERLAP MTL FLASHINGOVERLAP MTL FLASHING
GALV. MTL Z-FLASHING WITHGALV. MTL Z-FLASHING WITHGALV. MTL Z-FLASHING WITHGALV. MTL Z-FLASHING WITH
KICKKICKKICKKICK
WRAP FLASHING TAPE AROUNDWRAP FLASHING TAPE AROUNDWRAP FLASHING TAPE AROUNDWRAP FLASHING TAPE AROUND
BASE OF INSULATION (AIR BARRIER)BASE OF INSULATION (AIR BARRIER)BASE OF INSULATION (AIR BARRIER)BASE OF INSULATION (AIR BARRIER)
CEMENT SIDING AND STARTERCEMENT SIDING AND STARTERCEMENT SIDING AND STARTERCEMENT SIDING AND STARTER
STRIPSTRIPSTRIPSTRIP
CL
R
CL
R
CL
R
CL
R
EX. XPS FOUNDATION INSULATIONEX. XPS FOUNDATION INSULATIONEX. XPS FOUNDATION INSULATIONEX. XPS FOUNDATION INSULATION
- PROVIDE PROTECTION BOARD- PROVIDE PROTECTION BOARD- PROVIDE PROTECTION BOARD- PROVIDE PROTECTION BOARD
WHERE EXPOSEDWHERE EXPOSEDWHERE EXPOSEDWHERE EXPOSED
T.O.S
22' - 6"
EG
PROVIDE UNDERLAY (IE FLASHINGPROVIDE UNDERLAY (IE FLASHINGPROVIDE UNDERLAY (IE FLASHINGPROVIDE UNDERLAY (IE FLASHING
TAPE) TO ISOLATE FLASHING FROMTAPE) TO ISOLATE FLASHING FROMTAPE) TO ISOLATE FLASHING FROMTAPE) TO ISOLATE FLASHING FROM
CEMENTCEMENTCEMENTCEMENT
AIR WAND WATER BARRIER ATAIR WAND WATER BARRIER ATAIR WAND WATER BARRIER ATAIR WAND WATER BARRIER AT
TAPED INSULATION SEAMS -TAPED INSULATION SEAMS -TAPED INSULATION SEAMS -TAPED INSULATION SEAMS -
WRAP TAPE OVER TOP OFWRAP TAPE OVER TOP OFWRAP TAPE OVER TOP OFWRAP TAPE OVER TOP OF
INSULATIONINSULATIONINSULATIONINSULATION
FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
CI GIRT WITH FASTENERSCI GIRT WITH FASTENERSCI GIRT WITH FASTENERSCI GIRT WITH FASTENERS FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1
DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.
PROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAIL
WRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPET
EX. TOP PLATEEX. TOP PLATEEX. TOP PLATEEX. TOP PLATE
CONTINOUS PLYWOOD NAILERCONTINOUS PLYWOOD NAILERCONTINOUS PLYWOOD NAILERCONTINOUS PLYWOOD NAILER
FIRESTONE T-12FIRESTONE T-12FIRESTONE T-12FIRESTONE T-12
NEW CONTINUOUS METALNEW CONTINUOUS METALNEW CONTINUOUS METALNEW CONTINUOUS METAL
COPING AND ANCHOR CLIP WITHCOPING AND ANCHOR CLIP WITHCOPING AND ANCHOR CLIP WITHCOPING AND ANCHOR CLIP WITH
FASTENERS. SEE T-12 DETAIL.FASTENERS. SEE T-12 DETAIL.FASTENERS. SEE T-12 DETAIL.FASTENERS. SEE T-12 DETAIL.
UPPER LEVEL
0' - 0"
E13
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
T.O.S
22' - 6"
POOL DECK ENTRYPOOL DECK ENTRYPOOL DECK ENTRYPOOL DECK ENTRY
A109A
EXIST POOL DECKEXIST POOL DECKEXIST POOL DECKEXIST POOL DECK
A109
ROOF TYPE 1ROOF TYPE 1ROOF TYPE 1ROOF TYPE 1
EX. GLULAM LEDGEREX. GLULAM LEDGEREX. GLULAM LEDGEREX. GLULAM LEDGER
AX302
8
AX302
6
Sim
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
EX. JOISTSEX. JOISTSEX. JOISTSEX. JOISTS
CEILING AND SOFFITCEILING AND SOFFITCEILING AND SOFFITCEILING AND SOFFIT
WALL IN BASE SCOPEWALL IN BASE SCOPEWALL IN BASE SCOPEWALL IN BASE SCOPE
OF WORKOF WORKOF WORKOF WORK
EX. COLUMN BEYONDEX. COLUMN BEYONDEX. COLUMN BEYONDEX. COLUMN BEYOND
NEW KERFED ACOUSTICNEW KERFED ACOUSTICNEW KERFED ACOUSTICNEW KERFED ACOUSTIC
PANELSPANELSPANELSPANELS
AX302
5
Sim
WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):WALL CONSTRUCTION A (EX. STUD):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO STUDS PER MFR
3.3.3.3.1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER1.5" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*EX. 1/2" EXTERIOR GYP BD SHEATHING*
5.5.5.5.EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)EX. 2X6 STUDS, 16" OC (VIF)
6.6.6.6.EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*EX. 6 MIL VAPOR BARRIER*
7.7.7.7.EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*EX. 1/2" STRUCTURAL PLYWOOD*
8.8.8.8.INTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTEDINTERIOR FINISH AS NOTED
* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED* INSPECT AND REPLACE WHEN DETERIORATED
U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4U-FACTOR = .050 PER ASHRAE 90.1 TABLE A3.4
E13
CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,
SECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOT
CAULKCAULKCAULKCAULK
1/4" GAP - CAULK1/4" GAP - CAULK1/4" GAP - CAULK1/4" GAP - CAULK
FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
WATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER AT
TAPED INSUALTION SEAMSTAPED INSUALTION SEAMSTAPED INSUALTION SEAMSTAPED INSUALTION SEAMS
CI GIRTCI GIRTCI GIRTCI GIRT
5-1/2" X 3/4" CEMENT TRIM5-1/2" X 3/4" CEMENT TRIM5-1/2" X 3/4" CEMENT TRIM5-1/2" X 3/4" CEMENT TRIM
BOARDBOARDBOARDBOARD
ACOUSTIC PANEL KERFEDACOUSTIC PANEL KERFEDACOUSTIC PANEL KERFEDACOUSTIC PANEL KERFED
SPLINE SHOWN HERE. OCCURSSPLINE SHOWN HERE. OCCURSSPLINE SHOWN HERE. OCCURSSPLINE SHOWN HERE. OCCURS
AT OTHER ELEVATIONS.AT OTHER ELEVATIONS.AT OTHER ELEVATIONS.AT OTHER ELEVATIONS.
EX. 2X6 CONSTRUCTIONEX. 2X6 CONSTRUCTIONEX. 2X6 CONSTRUCTIONEX. 2X6 CONSTRUCTION
EX. PLYWOODEX. PLYWOODEX. PLYWOODEX. PLYWOOD
TOP EX
12' - 4"
EG
FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1
DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.
PROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAIL
WRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPETWRAP EPDM MEBRANE OVER PARAPET
TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.TERMINATE CLADDING HERE.
CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.CONTINUE INSULATION TO ROOF.
FIRESTONE T-7FIRESTONE T-7FIRESTONE T-7FIRESTONE T-7
PROVIDE TERMINATION PROVIDE TERMINATION PROVIDE TERMINATION PROVIDE TERMINATION
COUNTERFLASHING PER T-7 DETAILCOUNTERFLASHING PER T-7 DETAILCOUNTERFLASHING PER T-7 DETAILCOUNTERFLASHING PER T-7 DETAIL
FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
CI GIRT AND FASTENERSCI GIRT AND FASTENERSCI GIRT AND FASTENERSCI GIRT AND FASTENERS
AIR AND WATER BARRIER AT TAPEDAIR AND WATER BARRIER AT TAPEDAIR AND WATER BARRIER AT TAPEDAIR AND WATER BARRIER AT TAPED
INSULATION SEAMSINSULATION SEAMSINSULATION SEAMSINSULATION SEAMS
PLYWOOD SUBSTRATE EXPECTED ATPLYWOOD SUBSTRATE EXPECTED ATPLYWOOD SUBSTRATE EXPECTED ATPLYWOOD SUBSTRATE EXPECTED AT
GLULAM LOCATIONS - REPLACE IFGLULAM LOCATIONS - REPLACE IFGLULAM LOCATIONS - REPLACE IFGLULAM LOCATIONS - REPLACE IF
DETERIORATEDDETERIORATEDDETERIORATEDDETERIORATED EX. GLULAMEX. GLULAMEX. GLULAMEX. GLULAM
EXISTING 2X6EXISTING 2X6EXISTING 2X6EXISTING 2X6
CONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTION
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
As indicated
4/
1
7
/
2
0
1
7
4
:
5
2
:
1
0
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATIC CENTER
RENOVATION -
SECTIONS AND
DETAILS
AX302
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1/2" = 1'-0"4 Section @ GRID EC
1/2" = 1'-0"3 Section @ GRID E2
1/2" = 1'-0"1 Section @ GRID EG
1 1/2" = 1'-0"7 BASE FLASHING @ CMU WALL
1 1/2" = 1'-0"5 PARAPET AND HIGH ROOF TIE-IN, TYP
1/2" = 1'-0"2 Section @ GRID E13
1 1/2" = 1'-0"8 CLADDING TRIM AND TRANSITION, TYP
1 1/2" = 1'-0"6 FLASHING@ LOW EPDM ROOF, TYP
DISCLAIMER:
DETAILS DEPICT CONDITIONS AS DESCRIBED
BY RECORD DRAWINGS AND MAY NOT
REFLECT ACTUAL AS-BUILT CONDITIONS.
CONTRACTORS TO TO VERIFY ALL
CONDITIONS IN FIELD.
T ectonic Copyrig ht 2007
E14
TOP EX
12' - 4"
FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1FIRESTONE BT-1
DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.DEMO EX. BLOCKING AND FLASHING.
PROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAILPROVIDE BT-1 BASE TIE-IN DETAIL
FIRESTONE T-3FIRESTONE T-3FIRESTONE T-3FIRESTONE T-3
PROVDE REGLET COUNTERFLASHINGPROVDE REGLET COUNTERFLASHINGPROVDE REGLET COUNTERFLASHINGPROVDE REGLET COUNTERFLASHING
AND TERMINATION PER T-3 DETAILAND TERMINATION PER T-3 DETAILAND TERMINATION PER T-3 DETAILAND TERMINATION PER T-3 DETAIL
EXISTING PARAPETEXISTING PARAPETEXISTING PARAPETEXISTING PARAPET
CONSTRUCTION AND CAP TOCONSTRUCTION AND CAP TOCONSTRUCTION AND CAP TOCONSTRUCTION AND CAP TO
REMAINREMAINREMAINREMAIN
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
UPPER LEVEL
0' - 0"
E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
EX. 8" CMUEX. 8" CMUEX. 8" CMUEX. 8" CMU
EX. 2' RIGID INSULATIONEX. 2' RIGID INSULATIONEX. 2' RIGID INSULATIONEX. 2' RIGID INSULATION
EX. AIR GAPEX. AIR GAPEX. AIR GAPEX. AIR GAP
1'-2"1'-2"1'-2"1'-2"
EX. BLOCK VENEEREX. BLOCK VENEEREX. BLOCK VENEEREX. BLOCK VENEER
APPROX. PREVIOUS GRADEAPPROX. PREVIOUS GRADEAPPROX. PREVIOUS GRADEAPPROX. PREVIOUS GRADE
EX. MEMBRANE FLASHINGEX. MEMBRANE FLASHINGEX. MEMBRANE FLASHINGEX. MEMBRANE FLASHING
EX. ROWLOCK SILLEX. ROWLOCK SILLEX. ROWLOCK SILLEX. ROWLOCK SILL
NEW ROWLOCK SILL BLOCKNEW ROWLOCK SILL BLOCKNEW ROWLOCK SILL BLOCKNEW ROWLOCK SILL BLOCK
NEW BLOCK VENEERNEW BLOCK VENEERNEW BLOCK VENEERNEW BLOCK VENEER
3/4" AIR GAP3/4" AIR GAP3/4" AIR GAP3/4" AIR GAP
NEW 1.5" POLYSIO, SEAMS TAPEDNEW 1.5" POLYSIO, SEAMS TAPEDNEW 1.5" POLYSIO, SEAMS TAPEDNEW 1.5" POLYSIO, SEAMS TAPED
WEEPS 24" OC AND BASE FLASHINGWEEPS 24" OC AND BASE FLASHINGWEEPS 24" OC AND BASE FLASHINGWEEPS 24" OC AND BASE FLASHING
IF FOUNDATION MODIFCATION PERIF FOUNDATION MODIFCATION PERIF FOUNDATION MODIFCATION PERIF FOUNDATION MODIFCATION PER
3/S311 IS REQUIRED UPON3/S311 IS REQUIRED UPON3/S311 IS REQUIRED UPON3/S311 IS REQUIRED UPON
INSPECTION OF EXISTING CONDITIONS,INSPECTION OF EXISTING CONDITIONS,INSPECTION OF EXISTING CONDITIONS,INSPECTION OF EXISTING CONDITIONS,
EXTEND CONCRETE UPWARD TOEXTEND CONCRETE UPWARD TOEXTEND CONCRETE UPWARD TOEXTEND CONCRETE UPWARD TO
PROVIDE BRICK LEDGE; OTHERWISEPROVIDE BRICK LEDGE; OTHERWISEPROVIDE BRICK LEDGE; OTHERWISEPROVIDE BRICK LEDGE; OTHERWISE
PROVIDE STEEL SHELF ANGLE; COORDPROVIDE STEEL SHELF ANGLE; COORDPROVIDE STEEL SHELF ANGLE; COORDPROVIDE STEEL SHELF ANGLE; COORD
WITH ARCHWITH ARCHWITH ARCHWITH ARCH
AX303
4
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
2' - 8"2' - 8"2' - 8"2' - 8"
MASONRY TIES, 16" OC VERT ANDMASONRY TIES, 16" OC VERT ANDMASONRY TIES, 16" OC VERT ANDMASONRY TIES, 16" OC VERT AND
32" OC HORZ32" OC HORZ32" OC HORZ32" OC HORZ
UPPER LEVEL
0' - 0"
E14
TOP EX
12' - 4"
EXISTING FFE
0' - 0"
EX. FOUND
-3' - 0"
NEW CONSTRUCTION BEYONDNEW CONSTRUCTION BEYONDNEW CONSTRUCTION BEYONDNEW CONSTRUCTION BEYOND
NEW FIRE WALL PARAPET BEYONDNEW FIRE WALL PARAPET BEYONDNEW FIRE WALL PARAPET BEYONDNEW FIRE WALL PARAPET BEYOND
WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):WALL CONSTRUCTION B (EX. CMU):
1.1.1.1.FIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDINGFIBER CEMENT SIDING
2.2.2.2.KNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFRKNIGHT CI GIRTS, 16"OC, FASTENED TO CMU PER MFR
3.3.3.3.2" POLYISO INSULATION, SEAMS TAPED FOR WATER2" POLYISO INSULATION, SEAMS TAPED FOR WATER2" POLYISO INSULATION, SEAMS TAPED FOR WATER2" POLYISO INSULATION, SEAMS TAPED FOR WATER
AND AIR BARRIERAND AIR BARRIERAND AIR BARRIERAND AIR BARRIER
4.4.4.4.EX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMUEX. 8'' REINFORCED CMU
REBUILD PARAPET THROUGHREBUILD PARAPET THROUGHREBUILD PARAPET THROUGHREBUILD PARAPET THROUGH
THIS INFILL SECTIONTHIS INFILL SECTIONTHIS INFILL SECTIONTHIS INFILL SECTION
COORDINATE NEW PARAPET CAPCOORDINATE NEW PARAPET CAPCOORDINATE NEW PARAPET CAPCOORDINATE NEW PARAPET CAP
WITH ARCHITECTWITH ARCHITECTWITH ARCHITECTWITH ARCHITECT
AX302
7
Sim
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
AX303
4
Sim
E2
TOP EX
12' - 4"
CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,CONT. GALV. MTL Z-FLASHING,
SECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOTSECURED TO GIRTS, DO NOT
CAULKCAULKCAULKCAULK
WATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER ATWATER AND AIR BARRIER AT
TAPED INSUALTION SEAMSTAPED INSUALTION SEAMSTAPED INSUALTION SEAMSTAPED INSUALTION SEAMS
CI GIRT, TERMINATE ATCI GIRT, TERMINATE ATCI GIRT, TERMINATE ATCI GIRT, TERMINATE AT
BASE PLATEBASE PLATEBASE PLATEBASE PLATE
13' - 4"13' - 4"13' - 4"13' - 4"
1.5" POLYISO, SEAMS TAPED1.5" POLYISO, SEAMS TAPED1.5" POLYISO, SEAMS TAPED1.5" POLYISO, SEAMS TAPED
RE-START CI GIRTRE-START CI GIRTRE-START CI GIRTRE-START CI GIRT
2" POLYISO ON CMU, SEAMS2" POLYISO ON CMU, SEAMS2" POLYISO ON CMU, SEAMS2" POLYISO ON CMU, SEAMS
TAPED, TAPE ALSO SEAM ATTAPED, TAPE ALSO SEAM ATTAPED, TAPE ALSO SEAM ATTAPED, TAPE ALSO SEAM AT
TRANSITIONTRANSITIONTRANSITIONTRANSITION
ALTER HEIGHT OF THESE TWOALTER HEIGHT OF THESE TWOALTER HEIGHT OF THESE TWOALTER HEIGHT OF THESE TWO
SIDING PIECES AS NECESSARY TOSIDING PIECES AS NECESSARY TOSIDING PIECES AS NECESSARY TOSIDING PIECES AS NECESSARY TO
MAINTAIN SIDING 'COURSING'MAINTAIN SIDING 'COURSING'MAINTAIN SIDING 'COURSING'MAINTAIN SIDING 'COURSING'
ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3ROOF TYPE 3
ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2ROOF TYPE 2
NO CLADDING BELOW SILL-NO CLADDING BELOW SILL-NO CLADDING BELOW SILL-NO CLADDING BELOW SILL-
PROVIDE1.5" POLYISO AND WRAPPROVIDE1.5" POLYISO AND WRAPPROVIDE1.5" POLYISO AND WRAPPROVIDE1.5" POLYISO AND WRAP
EPDM UP WALL. PROVIDEEPDM UP WALL. PROVIDEEPDM UP WALL. PROVIDEEPDM UP WALL. PROVIDE
TERMINATION PER EPDM MFR.TERMINATION PER EPDM MFR.TERMINATION PER EPDM MFR.TERMINATION PER EPDM MFR.
PROVIDE NEW FLASHING AT SILL.PROVIDE NEW FLASHING AT SILL.PROVIDE NEW FLASHING AT SILL.PROVIDE NEW FLASHING AT SILL.
AX301
6
Sim
WALL TYPE AWALL TYPE AWALL TYPE AWALL TYPE A
BUTBUTBUTBUT IF CI GIRTS PROVE UNFEASIBLE IN IF CI GIRTS PROVE UNFEASIBLE IN IF CI GIRTS PROVE UNFEASIBLE IN IF CI GIRTS PROVE UNFEASIBLE IN
THIS AREA ONLY, APPLY SIDING ANDTHIS AREA ONLY, APPLY SIDING ANDTHIS AREA ONLY, APPLY SIDING ANDTHIS AREA ONLY, APPLY SIDING AND
TRIM DIRECTLY THRU INSULATION TOTRIM DIRECTLY THRU INSULATION TOTRIM DIRECTLY THRU INSULATION TOTRIM DIRECTLY THRU INSULATION TO
SUBSTRATE. FASTENERS PER SIDINGSUBSTRATE. FASTENERS PER SIDINGSUBSTRATE. FASTENERS PER SIDINGSUBSTRATE. FASTENERS PER SIDING
MFR FOR THIS APPLICATION - COORDMFR FOR THIS APPLICATION - COORDMFR FOR THIS APPLICATION - COORDMFR FOR THIS APPLICATION - COORD
WITH ARCHITECTWITH ARCHITECTWITH ARCHITECTWITH ARCHITECT
EXISTING FRAMINGEXISTING FRAMINGEXISTING FRAMINGEXISTING FRAMING
UNCLEAR BUT TO REMAINUNCLEAR BUT TO REMAINUNCLEAR BUT TO REMAINUNCLEAR BUT TO REMAIN
AX303
6
EXISTING WINDOW TOEXISTING WINDOW TOEXISTING WINDOW TOEXISTING WINDOW TO
REMAIN - PROVIDE NEWREMAIN - PROVIDE NEWREMAIN - PROVIDE NEWREMAIN - PROVIDE NEW
SEALANT AT PERIMETERSEALANT AT PERIMETERSEALANT AT PERIMETERSEALANT AT PERIMETER
SIKA 1-1ASIKA 1-1ASIKA 1-1ASIKA 1-1A
PROVIDE HOOK STRIP, FLASHINGPROVIDE HOOK STRIP, FLASHINGPROVIDE HOOK STRIP, FLASHINGPROVIDE HOOK STRIP, FLASHING
AND WELD PER SIKA DETAIL 1-1AAND WELD PER SIKA DETAIL 1-1AAND WELD PER SIKA DETAIL 1-1AAND WELD PER SIKA DETAIL 1-1A
(OR SIM). PROVIDE ADEQUATE(OR SIM). PROVIDE ADEQUATE(OR SIM). PROVIDE ADEQUATE(OR SIM). PROVIDE ADEQUATE
LENGTH TO COVER FRAMING.LENGTH TO COVER FRAMING.LENGTH TO COVER FRAMING.LENGTH TO COVER FRAMING.
EX FRAMING MEMBERS AT RAKEEX FRAMING MEMBERS AT RAKEEX FRAMING MEMBERS AT RAKEEX FRAMING MEMBERS AT RAKE
NEW NAILERNEW NAILERNEW NAILERNEW NAILER
SCALE:
ISSUE DATE:
DRAWN BY:
REV'D BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
NO. DATE: TITLE/PURPOSE:
6.
1. 10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
7. 01-24-17 BULLETIN 007
8. 03-10-17 BULLETIN 008
9. 04-11-17 BULLETIN 009
10. 04-17-17 PR 004 / ALT 1 PERMIT
As indicated
4/
1
7
/
2
0
1
7
4
:
5
2
:
1
7
P
M
C:
\
U
s
e
r
s
\
l
m
c
l
a
u
g
h
l
i
n
\
D
o
c
u
m
e
n
t
s
\
E
V
C
C
-
c
e
n
t
r
a
l
_
l
m
c
l
a
u
g
hl
i
n
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
16003
AQUATICS CENTER
RENOVATION -
SECTIONS AND
DETAILS
AX303
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
1 1/2" = 1'-0"4 LOW ROOF AT CMU PARAPET
1/2" = 1'-0"1 Section @ GRID E14
1/2" = 1'-0"2 Section @ GRID E14 NORTH
1 1/2" = 1'-0"5 SIDING @ T.O. CMU
1" = 1'-0"3 Partial Section @ TRIANGLE WINDOW NEAR ED & EF
1 1/2" = 1'-0"6 EXPOSED METAL ROOF RAKE
DISCLAIMER:
DETAILS DEPICT CONDITIONS AS DESCRIBED
BY RECORD DRAWINGS AND MAY NOT
REFLECT ACTUAL AS-BUILT CONDITIONS.
CONTRACTORS TO TO VERIFY ALL
CONDITIONS IN FIELD.
1)GENERAL:
1A)ALL WORK SHALL CONFORM WITH ACI 301-10, UNLESS NOTED OTHERWISE IN DRAWINGS OR PROJECT
SPECIFICATIONS.
1B)DETAIL BARS IN ACCORDANCE WITH THE DRAWINGS, PROJECT SPECIFICATIONS, AND ACI PUBLICATION SP-66
(2004): “ACI DETAILING MANUAL”
2)REINFORCING MATERIALS:
2A)SEE ‘REINFORCING MATERIALS TABLE’
3)REINFORCING FABRICATION:
3A)SPLICES:
-NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON DRAWINGS. MAKE BARS CONTINUOUS
AROUND CORNERS WHERE DETAIL NOT PROVIDED. WHERE PERMITTED, SPLICES MAY BE MADE BY CONTACT LAPS
OR MECHANICAL CONNECTORS.
-SEE ‘LAP SPLICE SCHEDULE’, ON FOR LAP LENGTHS.
-SPLICE CONTINUOUS BARS IN WALLS, BEAMS, AND STEM WALLS ‘LTS’ UNLESS NOTED OTHERWISE.
3B)MISCELLANEOUS REINFORCING REQUIREMENTS:
-PROVIDE ADDITIONAL BARS OR STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING CONCRETE
PLACEMENT.
-MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR’S SHOP UNLESS NOTED.
-NO WELDING OF REINFORCING PERMITTED UNLESS NOTED ON DRAWINGS. WHERE PERMITTED, PERFORM
WELDING IN ACCORDANCE WITH AWS D1.4-2011.
-PROVIDE ADDED REINFORCING TO TRIM ALL OPENINGS, NOTCHES, AND REENTRANT CORNERS AS NOTED IN
TYPICAL DETAILS.
4)STRUCTURAL CONCRETE MIX REQUIREMENTS:
4A)SEE ‘CONCRETE MIX TABLE’
5)SLAB-ON-GRADE:
5A)VERIFY ALKALINITY OF CONCRETE SURFACE, SLAB VAPOR TRANSMISSION, AND SLAB FLATNESS/LEVELNESS ARE
COMPATIBLE WITH FLOORING SYSTEM AND ADHESIVES PRIOR TO INSTALLING FLOORING.
5B)TAKE PRECAUTIONS TO MINIMIZE SLAB CURLING. GRIND SLAB OR USE LEVELING COMPOUND IF FLOOR
FLATNESS AND LEVELNESS VALUES ARE NOT ACCEPTABLE TO THE ARCHITECT.
6)NON-SHRINK GROUT:
6A)CONFORM TO ASTM C1107
6B)ACHIEVE 6000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
7)PLACING REINFORCEMENT:
7A)REINFORCEMENT PROTECTION:
-SEE 'REBAR COVER TABLE’ ON
-SEE ACI 117-10 FOR REINFORCEMENT PLACING TOLERANCES
7B)PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AND WELDED WIRE
REINFORCEMENT AT POSITIONS SHOWN ON PLANS. ALL REINFORCING, DOWELS, BOLTS, AND EMBEDDED PLATES
SHALL BE SET AND TIED IN PLACE BEFORE THE CONCRETE IS POURED. “STABBING” INTO PREVIOUSLY PLACED
CONCRETE IS NOT PERMITTED.
8)CONSTRUCTION/CONTROL JOINTS:
8A)SUBMIT DRAWINGS SHOWING CONSTRUCTION AND CONTROL JOINT LOCATIONS ALONG WITH THE SEQUENCE
OF POURS. CONSTRUCTION JOINT LOCATIONS AND CASTING SEQUENCE SHALL BE ARRANGED TO MINIMIZE THE
EFFECTS OF ELASTIC AND LONG-TERM SHORTENING/SHRINKAGE.
8B)CONSTRUCTION JOINTS IN SLABS-ON-DECK, SLABS-ON-GRADE, AND STRUCTURAL SLABS SHALL BE LOCATED TO
ACCOMMODATE THE MAXIMUM LENGTH AND AREA THE CONTRACTOR CAN REASONABLY POUR, FINISH, AND JOINT
IN THE SAME DAY, BUT SHALL NOT EXCEED 150 FEET WITH A MAXIMUM AREA OF 15,000 SQUARE FEET UNLESS
APPROVED BY THE ENGINEER.
8C)CONCRETE CONSTRUCTION JOINT SURFACE SHALL BE CLEANED AND ALL LAITANCE AND LOOSE MATERIAL
REMOVED PRIOR TO SECOND CONCRETE PLACEMENT.
8D)SHEAR FRICTION JOINTS: WHERE CONSTRUCTION JOINTS ARE LABELED OR SHOWN AS “ROUGHENED” ON THE
DRAWINGS, THE ENTIRE JOINT SURFACE SHALL BE MECHANICALLY ROUGHENED TO A 1/4” AMPLITUDE AND
THOROUGHLY CLEANED. EXPOSE THE COARSE AGGREGATE IN THE HARDENED CONCRETE AND REMOVE ALL
LAITANCE AND LOOSE MATERIAL.
9)MEP AND OTHER OPENINGS AND EMBEDMENTS:
9A)PROVIDE SLEEVES AT OPENINGS (SUCH AS THOSE REQUIRED FOR PLUMBING AND ELECTRICAL PENETRATIONS)
BEFORE PLACING CONCRETE. REMOVE METAL DECK AT SLEEVES AFTER CONCRETE HAS CURED. DO NOT CUT
REINFORCING WHICH MAY CONFLICT. CORING OF CONCRETE IS NOT PERMITTED.
9B)REFER TO TYPICAL DETAILS FOR SPACING LIMITS ON SLEEVES AND FOR REQUIREMENTS FOR EMBEDDED
CONDUIT AND PIPE.
CONCRETE NOTES
10/S390
10/S390
1)INSTALLATION REQUIREMENTS:
1A)ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S PRINTED INSTALLATION
INSTRUCTIONS AND PER MANUFACTURER'S ON-SITE TRAINING.
1B)ALL ADHESIVE ANCHORS AND ADHESIVE ANCHORED REINFORCEMENT DESIGNS ARE FOR INSTALLATION IN THE
FOLLOWING CONDITIONS, UNLESS NOTED OTHERWISE. WRITTEN APPROVAL MUST BE RECEIVED FROM ENGINEER PRIOR
TO INSTALLATION IN ALTERNATE CONDITIONS.
-DRY CONCRETE, UNLESS NOTED OTHERWISE.
-CONCRETE TEMPERATURE AT TIME OF INSTALLATION THROUGH CURE TIME MUST BE WITHIN THE TEMPERATURE
RANGE SPECIFIED IN MANUFACTURER'S PRINTED INSTALLATION INSTRUCTION FOR ADHESIVE GEL AND CURE TIMES.
-ANCHOR HOLES TO BE HAMMER DRILLED AND CLEANED.
-CONCRETE MUST BE AT LEAST 21 DAYS OLD BEFORE INSTALLATION OF ANCHORS.
-HOLES TO BE CLEANED AND PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION
INSTRUCTIONS AND EVALUATION REPORT PRIOR TO ADHESIVE INJECTION.
1C)THE POSITION OF EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE SHALL BE LOCATED PRIOR TO
INSTALLING POST INSTALLED ANCHORS OR REINFORCEMENT. EXISTING REINFORCEMENT SHALL BE LOCATED USING A
SCANNER, GPR, X-RAY, CHIPPING OR OTHER MEANS. DO NOT DAMAGE OR CUT EXISTING REINFORCEMENT.
2)SUBSTITUTION REQUESTS:
2A)SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL
ENGINEER PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS AND PRODUCT DATA DEMONSTRATING THAT THE
SUBSTITUTED PRODUCT IS IN COMPLIANCE WITH THE RELEVANT BUILDING CODES, PROVIDES EQUIVALENT LOAD
RESISTANCE, INSTALLATION CATEGORY, CREEP APPROVAL, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE
OF THE SPECIFIED PRODUCT.
POST-INSTALLED ANCHOR NOTES
1)DEFINITIONS:
1A)STRUCTURAL MASONRY IS DEFINED AS BEING EITHER LOAD BEARING AND/OR SERVING AS PART OF THE LATERAL LOAD
RESISTING SYSTEM. STRUCTURAL MASONRY IS SHOWN ON THE STRUCTURAL PLANS AND DEFINED IN SCHEDULES AND
DETAILS ON THE STRUCTURAL DRAWINGS.
1B)SEE ARCHITECTURAL DRAWINGS FOR LOCATION, THICKNESS AND EXTENT OF MASONRY PARTITIONS. SEE DETAILS ON
SHEET S450 FOR GENERAL MASONRY PARTITION REQUIREMENTS.
2)DESIGN STRENGTH:
2A)DEVELOP 2000 PSI COMPRESSIVE STRENGTH (f’m) IN 28 DAYS.
2B)STEEL REINFORCING:
-PRIMARY REINFORCING: ASTM A615, 60 KSI
-HORIZONTAL JOINT REINFORCING: ASTM A82, PREFABRICATED, LADDER TYPE
3)SPLICES:
3A)SEE MASONRY LAP SPLICE SCHEDULE FOR LAP LENGTHS.
4)INSTALLATION REQUIREMENTS:
4A)GROUT SOLID ALL CELLS CONTAINING REINFORCING, EMBEDDED ITEMS, AND ALL OTHER CELLS NOTED ON THE
CONTRACT DOCUMENTS.
MASONRY NOTES
1)CONNECTIONS:
1A)PROVIDE CONNECTIONS AS SHOWN IN THE ‘STEEL BEAM CONNECTION SCHEDULES’ ON SHEETS S510 & S511
AND DETAILS HEREIN. REFER TO SPECIFICATION FOR ALTERNATIVES AND CONNECTIONS NOT SHOWN.
2)WELDING REQUIREMENTS:
2A)WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS. QUALIFICATION
TESTS.
2B)MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16” FILLET, CONTINUOUS UNLESS OTHERWISE
NOTED.
2C)WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE
WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE.
2D)WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3
AND J2.4.
2E)ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED.
2F)FIELD WELDING SYMBOLS INDICATE SUGGESTED SEQUENCE CONSIDERED DURING DESIGN. THE
CONTRACTOR SHALL REQUEST APPROVAL FROM THE ENGINEER TO MODIFY WELD INSTALLATION LOCATION
INDICATED ON THE DOCUMENTS:
-FROM SHOP TO FIELD
-FROM FIELD TO SHOP
3)COMPOSITE GRAVITY FRAMING:
3A)COMPOSITE BEAMS ARE DESIGNED ASSUMING STUDS ARE INSTALLED IN THE WEAK POSITION (Rp = 0.6). SEE
TYPICAL METAL DECK DETAILS FOR PLACEMENT REQUIREMENTS.
3B)COMPOSITE GIRDERS ARE DESIGNED ASSUMING STUDS ARE WELDED THROUGH THE METAL DECK AND/OR
METAL DECKING/SHEET STEEL COVERS MORE THAN HALF OF THE TOP FLANGE (Rp = 0.75). SEE TYPICAL METAL
DECK DETAILS FOR PLACEMENT REQUIREMENTS.
4)CAMBER:
4A)FABRICATE BEAMS SUCH THAT ROLLING OR FABRICATION INDUCED CAMBER IS UP AFTER ERECTION.
4B)CAMBER SHOWN IS BASED ON THE COMPUTED DEFLECTION OF THE BEAM DUE TO SELF WEIGHT OF
CONCRETE PLACED. DESIGN IS BASED ON THE THEORETICAL CONCRETE THICKNESS PLUS 3/8” THICKNESS FOR
DECK LEVELING AND 1/2” THICKNESS FOR BEAM LEVELING. INCLUDE QUANTITY OF ADDED CONCRETE DUE TO
DECK AND BEAM DEFLECTION IN BID.
4C)VALUE NOTED ON PLAN IS IN-PLACE CAMBER, AFTER ERECTION, PRIOR TO PLACING CONCRETE. ADJUST
FABRICATION AS REQUIRED TO ACHIEVE CAMBER SPECIFIED WITHIN TOLERANCES.
5)STRUCTURAL STEEL INSTALLATION:
5A)ALL HIGH STRENGTH BOLTS USED IN COLUMN SPLICES, CONNECTIONS OF BEAMS AND GIRDERS TO
COLUMNS, AND WHERE NOTED ON THE DRAWINGS AS TYPE “SC” OR OTHER TYPE FOLLOWED BY “PT”, SHALL BE
TENSIONED TO THE VALUES OF TABLE J3.1 OF ANSI/AISC 360-10 . OTHER HIGH-STRENGTH BOLTS MAY BE
INSTALLED SNUG TIGHT AS DEFINED BY AISC.
6)STEEL JOISTS:
6A)DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE (SJI) STANDARD
SPECIFICATIONS, 43RD EDITION (2010).
6B)SIZE, TYPE, AND SPACING OF JOIST BRIDGING PER CURRENT SJI REQUIREMENTS. USE ‘X’ BRIDGING AT
DISCONTINUOUS ENDS OF BRIDGING UNLESS OTHERWISE NOTED ON PLANS OR DETAILS.
6C)REFER TO PLANS, DETAILS, AND JOIST LOAD MAP ON SHEET S010 FOR ADDITIONAL JOIST DESIGN
REQUIREMENTS INCLUDING UNBALANCED, CONCENTRATED, AXIAL, AND UPLIFT LOADS. THE STEEL JOIST
SUPPLIER SHALL DESIGN ALL JOISTS LABELED 'SP' FOR LOADING DESCRIBED IN JOIST LOAD MAP NOTES ON
SHEET S010.
6D)DESIGN JOISTS AND BRIDGING FOR NET UPLIFT FORCES INDICATED IN DESIGN CRITERIA.
7)METAL DECK:
7A)SEE ‘METAL DECK SCHEDULE’ ON SHEET S530 FOR MATERIALS, PROFILE, AND CONNECTIONS TO STRUCTURE.
7B)QUALITY CONTROL AND QUALITY ASSURANCE FOR STEEL DECK INSTALLATION SHALL BE IN ACCORDANCE
WITH SDI QA/QC-2011, “STANDARD FOR QUALITY CONTROL AND QUALITY ASSURANCE FOR THE INSTALLATION OF
STEEL DECK”.
7C)DECK DESIGN IS IN ACCORDANCE WITH STEEL DECK INSTITUTE (SDI) FLOOR DECK DESIGN MANUAL (2014), SDI
ROOF DECK DESIGN MANUAL (2013), AND SDI DIAPHRAGM DESIGN MANUAL, 4TH EDITION (2015)
7D)PLACE CONCRETE ON METAL DECK IN ACCORDANCE WITH SDI FLOOR DECK DESIGN MANUAL (2014) TO LIMIT
CONSTRUCTION LOADS TO ALLOWABLE MAGNITUDES.
7E)REINFORCE OPENINGS IN METAL ROOF DECK AND FLOOR DECK SUPPORTING CONCRETE FILL IN
ACCORDANCE WITH TYPICAL DECK OPENING DETAILS.
7F)INSTALL DECK OVER 4 SUPPORTS (3 SPAN CONTINUOUS) UNLESS NOTED OTHERWISE. DO NOT INSTALL DECK
AS SINGLE SPAN UNLESS SPECIFICALLY SHOWN ON DRAWINGS.
7G)PROVIDE DECK ATTACHMENTS AS NOTED ON DRAWINGS.
8)STRUCTURAL COLD FORMED STEEL FRAMING:
8A)COLD FORMED METAL FRAMING IS A PERFORMANCE SPECIFIED ITEM DESIGNED BY THE CONTRACTOR.
PROVIDE STUD DEPTH INDICATED ON THE DRAWINGS. DO NOT EXCEED MAXIMUM SPACING INDICATED. VARY
FLANGE WIDTH, GAGE, YIELD STRENGTH, BRACING, STUD SPACING, ETC. AS REQUIRED TO SATISFY
PERFORMANCE CRITERIA IN THE CONTRACT DOCUMENTS. MINIMUM STUD GAGE SPECIFIED IS REQUIRED FOR
ATTACHMENT OF OTHER MATERIALS TO STUDS. DO NOT BASE BIDS ON MINIMUM GAGE OR MAXIMUM SPACING
SPECIFIED.
8B)REFER TO DETAILS FOR MINIMUM CONNECTIONS AND OTHER REQUIREMENTS. DO NOT IMPOSE FORCES ON
THE BUILDING STRUCTURE IN DIRECTIONS OR AT LOCATIONS OTHER THAN THOSE SHOWN ON THE STRUCTURAL
DRAWINGS. DO NOT IMPOSE FORCES LARGER THAN SPECIFIED. CONNECTIONS TO CONCRETE SHALL NOT USE
PAFs TO RESIST TENSION LOADS.
STEEL NOTES
SCALE:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
PR
I
N
C
I
P
A
L
:
EO
R
:
DE
S
I
G
N
E
R
:
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
MM
J
O
B
#
:
DA
T
E
P
R
I
N
T
E
D
:
FI
L
E
P
A
T
H
:
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
NO. DATE: TITLE/PURPOSE:
6.
1.10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
3/4" = 1'-0"
5/
1
/
2
0
1
7
4
:
1
6
:
3
5
P
M
C:
\
P
r
o
j
\
1
6
.
0
1
1
7
.
S
.
0
1
-
E
S
T
E
S
_
C
O
M
M
U
N
I
T
Y
_
C
E
N
T
E
R
-
R
S
1
6_
e
s
a
b
i
a
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SABIA
EAGAN
10-31-2016
16.0117.S.01
NOTES
S003
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ED
S
A
B
I
A
,
K
A
T
I
E
H
O
Y
T
ED
S
A
B
I
A
RA
L
P
H
R
E
M
P
E
L
16
.
0
1
1
7
.
S
.
0
1
DW
I
G
H
T
G
I
L
B
E
R
T
SVT = CONTRACTOR SHALL PROVIDE CONCRETE WITH REDUCED WATER IN ORDER TO ACHIEVE THE
SLAB VAPOR TRANSMISSION REQUIRED FOR THE SPECIFIED FLOORING MATERIALS
c. ABBREVIATIONS FOR OTHER REQUIREMENTS AS FOLLOWS:
b. WHERE AIR CONTENT IS INDICATED IN THE MIX TABLE, PROVIDE AIR ENTRAINING ADMIXTURE. TOTAL AIR
CONTENT LIMITS INCLUDE BOTH ENTRAINED AND ENTRAPPED AIR +/- 1 1/2%. ‘NP’ IN COLUMN INDICATES
ADDITION OF ENTRAINED AIR IS NOT PERMITTED EXCEPT WHERE CONTRACTOR CAN DEMONSTRATE THAT SLABS
WITH ENTRAINED AIR WILL HAVE A FINISH ACCEPTABLE TO THE ARCHITECT WITHOUT BLISTERS. AIR CONTENT
NOTED IS BASED ON 3/4" AGGREGATE. IF 3/8” AGGREGATE IS USED, INCREASE AIR CONTENT BY 1 1/2%.
1”: #57 AGGREGATE
3/4”: #67 AGGREGATE
a. FOR THE MAXIMUM COARSE AGGREGATE SIZE INDICATED, USE THE FOLLOWING AGGREGATE SIZE NUMBERS
PER ASTM C33:
FOR CONCRETE PLACED BY PUMPING PROVIDE CONCRETE MIX FLOWABILITY TO FACILITATE PUMPING.
ENTRAINED AIR MAY BE USED TO FACILITATE PUMPING SUBJECT TO THE PROVISIONS OF NOTE b BELOW.
USE TYPE I / II PORTLAND CEMENT UNLESS NOTED OTHERWISE. FOR CONCRETE MIXES USED ON FLOORS
MINIMUM CEMENTITIOUS CONTENT SHALL BE 540 POUNDS PER CUBIC YARD
- PROVIDE WORKABILITY AND CONSISTENCY TO PERMIT CONCRETE TO BE WORKED READILY INTO FORMS AND
AROUND REINFORCEMENT UNDER CONDITIONS OF PLACEMENT TO BE EMPLOYED, WITHOUT SEGREGATION OR
EXCESSIVE BLEEDING. CONTRACTOR SHALL SELECT APPROPRIATE SLUMP. USE ADMIXTURES AS REQUIRED TO
OBTAIN DESIRED RESULTS.
- PROVIDE THE MINIMUM COMPRESSIVE STRENGTH AS INDICATED IN THE MIX TABLE. DO NOT EXCEED THE
MAXIMUM WATER-CEMENT RATIO NOTED.
PROPORTIONS OF MATERIALS IN CONCRETE MIX SHALL BE ESTABLISHED TO:
CONCRETE MIX TABLE NOTES:
7 ALL CONC OTHERWISE
NOT SPECIFIED 4 NWC 0.50 3/4 6 -
6
SLAB ON GRADE WITH
MOISTURE SENSITIVE
FLOORING
3.5 NWC - 1 NP SVT
5 INT SLABS ON GRADE 3.5 NWC - 1 NP
4 INT TOPPING SLABS,
SLABS ON DECK 3.5 NWC 0.50 3/4 NP
3
ALL CONC EXPOSED
TO WEATHER OR
DEICERS: BEAMS,
SLABS, WALLS
5 NWC 0.40 3/4 6 -
2
FOOTINGS,
PILASTERS, STEM
WALLS, BASEMENT
WALLS, EXPOSED TO
MOISTURE OR
FREEZING
4.5 NWC 0.45 3/4 5 -
1
FOOTINGS,
PILASTERS, STEM
WALLS, BASEMENT
WALLS NOT EXPOSED
TO MOISTURE OR
FREEZING
3 NWC - 1 - -
CONC
MIX
TYPE
INTENDED USE
28 DAY
STRENGTH f'c
(KSI)
CONC
WEIGHT
MAX W/C
RATIO,
INCLUDING
FLY ASH
MAX
AGGREGATE
SIZE (IN),
NOTE a
TOTAL AIR
CONTENT
(%), NOTE b
OTHER
REQTS, NOTE
c
CONCRETE MIX TABLE
SCREW ANCHORS HILTI KWIK HUS-EZ - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
EXPANSION ANCHORS
(IN GROUTED MASONRY)HILTI KWIK BOLT 3 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
EXPANSION ANCHORS
(IN CONCRETE)HILTI KWIK BOLT TZ - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE ANCHOR RODS -36
MIN
58
MIN
THREADED ROD,
UNGREASED
ADHESIVE
(IN GROUTED OR HOLLOW MASONRY)HILTI HIT-HY 70 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE
(IN CONCRETE W/>12" EMBEDMENT)HILTI HIT-RE 500 V3 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE
(IN CONCRETE)HILTI HIT-HY 200 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ANCHOR TYPE PRODUCT
Fy
(KSI)
Fu
(KSI)COMMENT
POST-INSTALLED ANCHOR TABLE
EPOXY COATING OF REINFORCING A775 OR A934 - - -
WELDED WIRE REINFORCING, DEFORMED A1064 70 80 -
WELDED WIRE REINFORCING, SMOOTH A1064 65 75 -
WELDED & FIELD BENT REINF A706 60 80 -
TYP REINFORCING A615 60 90 -
REINF ELEMENT ASTM Fy (KSI) Fu (KSI) COMMENTS
REINFORCING MATERIAL TABLE
WF, WT A992 50 65 --
WELDING ELECTRODES,
THICKNESS OF THINNER PART
≤ 0.1 INCHES (12 GA)
E60 OR E70 -- -- PER AWS
WELDING ELECTRODES,
THICKNESS OF THINNER PART
> 0.1 INCHES (12 GA)
E70 PER AWS
ROUND HSS A500 GR C 46 62 --
RECT HSS A500 GR C 50 62 --
PLATES A36 36 58 --
PIPE A53 GR B 35 60 --
OTHER SHAPES A36 36 58 --
HAS A108 51 65 STUDS ARE 3/4"Ø UNO
DAS A1064 70 80 --
COLD-FORMED TRACK, ALL
THICKNESSES A1003 33 -- --
COLD-FORMED STUDS/PLATE,
54 MIL AND HEAVIER A1003 50 -- --
COLD-FORMED STUDS/PLATE,
33 AND 43 MIL A1003 33 -- --
BOLTS IN WOOD A307 GR A -- 60 --
BOLTS F3125 - TYPE A325
OR F1852 -- 120
BOLTS ARE 3/4"Ø UNO, USE TENSION-
CONTROLLED WHERE POSSIBLE
ANCHOR RODS IN MASONRY F1554 GR 36, F1554
GR 55, OR A307
GRADE A/C
36 58 WELDABLE, STD HEX HEAD
ANCHOR RODS F1554 GR 55 55 75 WELDABLE, HEAVY HEX HEADED
STEEL ELEMENT ASTM/TYPE
Fy
(KSI)
Fu
(KSI)COMMENTS
STEEL MATERIAL TABLE
* 1 MIL = 1/1000"
NOTE:
12 97
14 68
16 54
18 43
20 33
22 27
GAUGE MINIMUM THICKNESS (MILS*)
METAL GAUGE CONVERSION
WOOD NOTES
1)LAMINATED MEMBER SIZES:
1A)LVL, GLU-LAM AND AND OTHER FABRICATED MEMBERS SIZES SHOWN ARE NET. OTHER MEMBER SIZES ARE NOMINAL.
2)FABRICATED LUMBER:
2A)FABRICATED LUMBER DESIGNATIONS ARE THOSE MANUFACTURED BY iLEVEL, BOISE, IDAHO.
2B)FABRICATED LUMBER IS DESIGNATED ON THE DRAWINGS AS ONE OF THE FOLLOWING: TJI JOISTS, MICROLLAM (LVL),
OR PARALLAM (PSL).
2C)THE MANUFACTURER SHALL PROVIDE WEB STIFFENERS ON I-JOISTS, END BLOCKING, BRIDGING, AND ERECTION
BRACING AS REQUIRED.
2D)FABRICATED LUMBER SHALL BE DRY.
3)GLUED LAMINATED MEMBERS:
3A)COMBINATION SYMBOL: 24F-V4, TRUSS DESIGNER MAY PROVIDE PROPERTIES AS DESIRED
3B)MINIMUM DESIGN VALUES ARE BASED ON THE 2012 NDS.
4)FRAMING LUMBER:
4A)DRY (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF INSTALLATION), DOUGLAS FIR-LARCH WITH MINIMUM DESIGN
VALUES BASED ON THE 2012 NDS. SILL PLATES SHALL BE STUD GRADE.
5)METAL CONNECTORS:
5A)FRAMING CONNECTOR DESIGNATIONS ARE THOSE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO,
CALIFORNIA. OTHER MANUFACTURER’S PRODUCTS MAY BE USED IF APPROVED BY THE ENGINEER. FURNISH NAILS AND/OR
BOLTS OF DIAMETER, LENGTH, AND NUMBER SPECIFIED BY THE MANUFACTURER FOR EACH CONNECTOR.
5B) INSTALL LAG SCREWS IN PRE-DRILLED HOLES IN MEMBER.
6)OPENINGS:
6A)OPENING, POCKETS, ETC., SHALL NOT BE PLACED IN BEAMS, JOISTS, RAFTERS, STUDS, POSTS, COLUMNS, TIMBER AND
OTHER STRUCTURAL MEMBERS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS.
7)SHEATHING:
1A)PLYWOOD:
-CONFORM TO U.S. DEPARTMENT OF COMMERCE STANDARD PS 1-10.
1B)WOOD STRUCTURAL PANELS (WSP)
-WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING CONFORMING TO U.S. DEPARTMENT OF COMMERCE
STANDARD PS 2-10.
-ALL WOOD PANELS SHALL BE EXPOSURE 1.
8)NAILING:
1A) UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE COMMON NAILS. MINIMUM NAILING SHALL BE IN
ACCORDANCE WITH THE TYPICAL WOOD CONNECTION SCHEDULE AND IBC 2015 TABLE 2304.10.1
1B)WHERE COMMON NAILS ARE SPECIFIED, BOX NAILS OF EQUAL LENGTH MAY BE SUBSTITUTED PROVIDED ONE BOX NAIL
IS ADDED FOR EVERY THREE COMMON NAILS SPECIFIED.
BULLETIN NO. 088. 03-10-17
8
PR 004- 05-01-17
31 7.9 9 10.3
L
M
M.6
N
P
Q
EH
EG
EF
EE
ED
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14
8'
-
0
"
30
'
-
0
"
8'
-
4
"
5'
-
8
"
18
'
-
0
"
175'-2"
S106
NJ
52
D
L
H
-
S
P
16
K
-
S
P
28K-SP
28K-SP
ER3.5A
20 GA
1.5B-F
16 GA
1.5B-D
20 GA
1.
5
B
-
F
16
G
A
1.5B-D
16 GA
6.4
W24x55
W1
2
x
1
9
W1
2x
19
70
'
-
0
"
5'-0"10'-4 1/2"79'-7 1/2"29'-0"33'-0"15'-0"3'-2"
WO
O
D
T
R
U
S
S
WO
O
D
T
R
U
S
S
HSS6x4x1/4
HSS6x4x1/4
HSS6x4x1/4
HSS6x4x1/4
HSS6x4x1/4
1.
5
B
-
D
20
G
A
3V
L
I
3
A
20
G
A
3V
L
I
3
A
20
G
A
8'
-
0
"
8'
-
0
"
16
S530
TYP
12
S520
ER3.5A
16 GA
ER3.5A
16 GA
ER3.5A
16 GA
ER3.5A
16 GA
1
S500SIM
HSS6x6x1/4
HSS6x6x1/4
HSS6x6x1/4
HS
S
8
x
8
x
1
/
2
HSS8x8x1/2
7
S520
9
S540
SLOPE
DOWN
SLOPE
DOWN
SLOPE
DOWN
KICKER
SL
O
P
E
DO
W
N
15
S530
10
S560
12
S560
HSS6x4x1/4
2
20k W18x35 20k 20k W18x35
20k W18x35 20k
W16x26
10
k
W1
4
x
3
8
10
k
10
k
W1
2
x
1
9
10
k
15
k
W1
4
x
3
8
15
k
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
6
x
2
6
10
k
W1
4
x
2
2
19
k
W12x19
10
k
W1
6
x
2
6
50k W18x35 20k
10
k
W1
2
x
1
9
2
S401
TYP3
S401
W24x68
( 24' - 9" )
( 14' - 8" )W18x35
20k
( 15' - 0" )
W18x35
( 20' - 1 7/8" )
23'-0"8'-0"
1'-3"23'-5"
8
S401
TYP
21
k
W1
8
x
3
5
(
14
'
-
9
1
/
2
"
)
31
k
W1
2
x
2
6
(
14
'
-
2
"
)
1.
5
B
-
E
18
G
A
2
S401
TYP
3'
-
2
1
/
2
"
3'
-
2
1
/
2
"
1'
-
6
"
6'
-
7
"
1'
-
2
"
4"
5'
-
1
"
1'
-
6
"
6'
-
3
"
1'
-
6
"
W1
2
x
2
6
(
14
'
-
2
"
)
10
S401
SIM
24
L
H
-
S
P
( 12' - 9 1/2" )( 13' - 4 1/2" )( 13' - 9 1/4" )
( 14' - 3 1/4" )( 14' - 9 1/2" )
( 13' - 8 1/2" )
( 13' - 8 1/2" )
( 14' - 1 1/4" )
W1
2
x
4
0
(
13
'
-
3
"
)
W36x135
( 24' - 9" )
3V
L
I
3
A
20
G
A
( 15' - 0" )
W16x26
( 14' - 4 1/4" )
1'-0"
10
15
S500
2
S401
TYP
B/DECK= 28' - 3 7/8"
B/DECK= 10' - 3 1/4"
2'
-
8
"
1'
-
6
"
6'
-
6
"
1'
-
6
"
4'
-
7
3
/
4
"
4'
-
7
3
/
4
"
4'
-
2
1
/
2
"
EQ EQ EQ EQ3'-0"2'-0"
6'
-
0
"
6'
-
0
"
6'
-
0
"
2'
-
6
"
HS
S
6
x
6
x
5
/
8
(
12
'
-
8
"
)
HS
S
6
x
6
x
5
/
8
(
10
'
-
5
"
)
B/DECK= 25' - 1 1/8"
B/DECK= 23' - 3"
25k
W16x26 25k
20
k
19
k
12
S401
TYP
12
S401
16
S401
13
S560
TYP
8'
-
0
"
2'
-
0
"
TYP
8 1/4"0"
10
S401
TYP
13
S500
SIM
12
S501
B/DECK= 13' - 8 5/8"
B/DECK= 13' - 0"
3
S511
1'-4 3/8
"
B/DECK= 23' - 1 3/4"
1
S501
2
S501
FUTURE MECH UNIT
9
S502
TYP
5
S502
SIM,
TYP
11
S401
EE OF
GIRT
4
S501
11
S401
SIM 3
S501
17
S500
1'
-
0
"
1'
-
1
5
/
8
"
17
S401
11
S502
6
S501
18
S401
5
S501
18
S401
1'
-
6
"
6"
8
S401
TYP
S531
12 TYP
EQ
EQ
EQ
EQ
EQ
5'
-
0
"
TYP
4
S520
TYP
13
S501
TYP
2
S401
3
S402
6
S402
2
S401
TYP
3
S401
20
S530
TYP
2
S501
SIM15
S530
SIM
20
S505
19
S401
12
S200
12
S401
SEE S106 FOR LOW BEAM AT
MASONRY WALL ALONG GRID L
B/DECK= 28' - 8 3/8"B/DECK= 17' - 0 1/2"
RE: ARCH 3'-7"
17
S501
17
S501
SIM
18
S501
SIM
1'-0"14k
10
S401
SIM
6
S401
TYP
4"
1'-0"
2'-2 1/2"
6
5'-0"8'-0"EQ EQ EQ EQ EQ EQ EQ EQ
6
6
1'-0"
6
6
6
6
6
6
HSS4x4x1/4 8
S520
6
TRIM FLANGE ON
POOL SIDE BACK
TO FACE OF WALL
6
11 1/2"
2'-0 1/2"
5'-0 1/2"
3
3
/
4
"
7'-0"22'-0"
S108
TYP
NEW 1 3/4
"x11 1/4"LVL @ 16" OC
10
S500
TYP
3
S561
6
S561
2
S561
TYP
TYP
5
S561
WS1 WS
1
NEW 1 3/4"x20" LVL @ 24" OC
14
S450
10
S500
7
S561
1
S561
TYP
TYP
4
S402
5
S402
8
S561
EXISTING SKYLIGHT. REMOVE (E)
HEADER AND TRUSSES FRAMING
INTO HEADER, REPLACE WITH
NEW LVLS @ 24" OC MAX
BETWEEN EXISTING DOUBLE
TRUSS
AT EXISTING SKYLIGHT,
REMOVE (E) HEADER AND
FRAMING JOIST. REPLACE
WITH NEW LVL @ 16" MAX
BETWEEN (E) (2)2X12
1
S561
TYP
(E) 2x12 @ 16"
(E) 8 3/4x48 GLULAM
(E) 8 3/4x48 GLULAM
(E) 22"WOOD TRUSS @ 24" OC
19
S561
19
S561
19
S561
SCALE:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
PR
I
N
C
I
P
A
L
:
EO
R
:
DE
S
I
G
N
E
R
:
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
MM
J
O
B
#
:
DA
T
E
P
R
I
N
T
E
D
:
FI
L
E
P
A
T
H
:
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
NO. DATE: TITLE/PURPOSE:
6.
1.10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
1/8" = 1'-0"
5/
1
/
2
0
1
7
4
:
1
6
:
3
7
P
M
C:
\
P
r
o
j
\
1
6
.
0
1
1
7
.
S
.
0
1
-
E
S
T
E
S
_
C
O
M
M
U
N
I
T
Y
_
C
E
N
T
E
R
-
R
S
1
6_
e
s
a
b
i
a
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SABIA
EAGAN
10-31-2016
16.0117.S.01
ROOF PLAN - SOUTH
S107
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ED
S
A
B
I
A
,
K
A
T
I
E
H
O
Y
T
ED
S
A
B
I
A
RA
L
P
H
R
E
M
P
E
L
16
.
0
1
1
7
.
S
.
0
1
DW
I
G
H
T
G
I
L
B
E
R
T
1/8" = 1'-0"
ROOF - SOUTH1
NORTH
NOTES:
1.SEE S106
PLAN NOTES:
1.SEE S000 SERIES SHEETS FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
2.SEE S530 FOR TYPICAL METAL DECK DETAILS AND SCHEDULE.
3.SEE S520 FOR TYPICAL STEEL JOIST DETAILS
4.SEE S010 FOR JOIST LOADING AND DESIGN CRITERIA FOR NONSTANDARD JOISTS NOTED AS “SP”.
5.TOP OF STRUCTURAL STEEL SHALL BE BOTTOM OF METAL DECK UNLESS NOTED OTHERWISE ON PLAN.
6.CONTRACTOR TO VERIFY ALL EQUIPMENT WEIGHTS, SIZES, LOCATIONS, AND OPENINGS REQUIRED WITH MECHANICAL CONTRACTOR. CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY CHANGES IN THE WEIGHTS OR LOCATIONS SHOWN ON
THE DRAWINGS. SUCH CHANGES IN CONDITIONS SHALL BE SUBJECT TO STRUCTURAL ENGINEER REVIEW. RE: MECHANICAL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL OPENINGS NOT SHOWN.
7.PROVIDE FIRST JOIST PARALLEL TO WALLS OR EDGES OF BUILDING WITH HALF THE STANDARD JOIST CAMBER.
8.ALL BEAM REACTIONS ARE FOR 10k (ULTIMATE) UNO.
PR 004- 05-01-17
31 7.9 9
Q
EH
EG
EF
EE
ED
EC
EB
EAE1E2E3E4E5E6E7E8E9E10E11E12E13E14
NJ
6.42
(E) 8 3/4x48 GLULAM
(E) 8 3/4x48 GLULAM
AT HATCHED REGIONS, (E) 8d NAILS
SHOULD BE AT 12" OC, PROVIDE
ADDITIONAL 8d NAILS SUCH THAT FINAL
SPACING IS NO MORE THAN 6" OC
10'-0"
S107
S561
9
S561
9TYP
TYP
13
S561
13
S561
17
S561
18
S561
15
S561
12
S561
12
S561
14
S561
12
S561
14
S561
SIM
16
S561
AT HATCHED REGIONS, (E) 8d NAILS SHOULD
BE AT 12" OC, PROVIDE ADDITIONAL 8d NAILS
SUCH THAT FINAL SPACING IS NO MORE
THAN 6" OC
10'-0"
16
S561SIM
SCALE:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
PR
I
N
C
I
P
A
L
:
EO
R
:
DE
S
I
G
N
E
R
:
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
MM
J
O
B
#
:
DA
T
E
P
R
I
N
T
E
D
:
FI
L
E
P
A
T
H
:
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
NO. DATE: TITLE/PURPOSE:
6.
1.10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
1/8" = 1'-0"
5/
3
1
/
2
0
1
7
6
:
5
7
:
4
5
P
M
C:
\
P
r
o
j
\
1
6
.
0
1
1
7
.
S
.
0
1
-
E
S
T
E
S
_
C
O
M
M
U
N
I
T
Y
_
C
E
N
T
E
R
-
R
S
1
6_
e
s
a
b
i
a
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
Checker
Author
10-31-2016
16.0117.S.01
ROOF PLAN -
EXISTING
S108
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ED
S
A
B
I
A
,
K
A
T
I
E
H
O
Y
T
ED
S
A
B
I
A
RA
L
P
H
R
E
M
P
E
L
16
.
0
1
1
7
.
S
.
0
1
DW
I
G
H
T
G
I
L
B
E
R
T
1/8" = 1'-0"
ROOF - EXISTING1
NORTH
PLAN NOTES:
1.SEE S561 FOR WOOD DETAILS AT EXISTING BUILDING
2.DO NOT OVERDRIVE NAILS OR SCREWS AT HIGH ROOF ABOVE POOL SPACE
EXISTING POOL ROOF EVALUATION DESIGN CRITERIA:
1.PER THE TOWN OF ESTES PARK BUILDING DEPARTMENT, IN LIEU OF MEETING THE REQUIREMENTS OF THE 2015 IEBC SECTION 707.3.2 FOR
THE PORTIONS OF THE EXISTING BUILDING BEING RE-ROOFED, THE EXISTING BUILDING'S ROOF DIAPHRAGMS, THE CONNECTION OF THE
ROOF DIAPHRAGM TO THE ROOF FRAMING MEMBERS, AND ROOF TO WALL CONNNECTIONS WILL BE STRENGTHED, AS NECESSARY, TO
MEET THE WIND LOAD REQUIREMENTS OF THE 1982 UBC
2.WIND SPEED = 90 MPH FASTEST WIND SPEED
3.EXPOSURE C FOR WIND LOAD FROM NORTH AND EXPOSURE B FOR WIND FROM SOUTH, EAST, AND WEST.
4.IMPORTANCE FACTOR = 1.15
PR 004- 05-01-17
PR 004 REVISION 2- 06-01-17
EG
BUILD TOP OF WALL TIGHT TO UNDERSIDE
OF TREATED 2x8 NAILED TO UNDERSIDE OF
(E) GLULAM, GROUT ANY GAPS BETWEEN
PLATE AND WALL SOLID
L3x3x1/4 W/ 3/4"Øx6" LAG SCREW @ 8"OC
1
S561
4"
(4) 10d NAILS
2x8 W/ (3) #14x5" WOOD
SCREWS @ 16" OC FOR
10' EAST OF GRID E9
SIMPSON A44 W/ (8) 10d NAILS
@ EACH LVL, NAIL DIRECTLY
TO GLULAM WHEN 2x8 IS NOT
PRESENT
4"
CONT 2x4 SILL, ATTACH
TO ANGLE W/ HILTI X-U
27 PAFS @ 18" OC
L6x4x5/16xCONT W/ 3/4”Øx5” EMBED EXP BOLT @
12” OC MAX INTO GROUTED CELL, GROUT
UNGROUTED CELLS WITHIN 8" OF BOLTS
10d NAILS FROM LVL TO (E)
TRUSS TOP CHORD @ 24” OC
(E) TRUSS BEYOND
ATTACH ADDITIONAL 2x4S TO SILL
WITH (2) 8d NAILS, MIN
TOE NAIL LVL TO SILLS
NOTE:
1.REMOVE AND REPLACE
EXISTING BLOCKING AS
NECESSARY TO INSTALL
NEW FRAMING.
1 3/4" MIN
1/2"x4 1/2" SCREW ANCHOR
@ 12" MAX, 8" MIN
(2) #14x5" WOOD SCREW
FROM TRUSS TO SILL
3" MAX
PROVIDE NEW LVL UNDER (E) JOISTS,
W/ (2) 10d NAILS TO EXISTING WALL
STUD
(9) 5/16"Ø BOLTS
1
S561
2
1
/
4
"
3
1
/
2
"
3
1
/
2
"
2"
MIN
4"
MIN
4"3"
8
2x8xCONT W/ (2) #14x5" WOOD
SCREWS @ EACH WALL STUD,
PROVIDE CMST12x8'-0" AT ANY
SPLICES
SIMPSON A44 W/ (8) 10d NAILS
@ EACH EXISTING JOIST
(E) 2x8 BLOCKING
GC TO CONFIRM
(2) 10d NAILS @ 16” OC
NOTE:
1.REMOVE AND REPLACE EXISTING BLOCKING AS
NECESSARY TO INSTALL NEW FRAMING.
6
PROVIDE NAILS PER 11/S561
TO EITHER NEW LVL OR (E)
JOIST
PL 1/2x1'-3"x14'-0", CENTERED ON (E) GLULAM.
FASTEN W/ (3) 3/4"Øx4" LAG SCREWS PER FOOT
THROUGH PRE-DRILLED HOLE IN PLATE. IF
PLATE REQUIRES SPLICE, PROVIDE 3/8" PJP
WELD FULL HEIGHT OF PLATE, COORDINATE
LOCATIONS OF HOLES AND SPLICES W/ (E)
TRUSSES AND NEW LVLS
(1) SIMPSON CMST12
STRAP, FILL ALL HOLES WITH
10d NAILS. EXTEND FROM
GRID EH TO 4'-0" SOUTH OF
GRID EG. PROVIDE
BLOCKING BELOW AS
NECESSARY.
(2) #14x5" WOOD SCREW
FROM TRUSS TO GLULAM
L4x4x1/4x0'-4"W/ 2x4 SILL
ATTACHED W/ (2) HILTI XU-26 PAFs
3/16
3/16
TOE NAIL LVL TO SILL
PL PER 5/S561
4
1
/
2
"
PROVIDE 1/2" RADIUS AT NOTCH
6
(3) 10d NAILS TO EXISTING FRAMING
REMOVE AND REPLACE EXISTING 2x BLOCKING
OPTION 1
1
S561
3" MAX
1
S561
(2) 10d TOENAIL TO TOP PLATE
6
OPTION 2
(9) 5/16"Ø BOLTS
2"
3
1
/
2
"
3
1
/
2
"
3"
MIN
4"
MIN
4"
8
AT (E) MASONRY CONTROL JOINTS, PROVIDE
(1) SIMPSON CMST12x8'-0" STRAPS ON TOP
OF 2x4 BLOCKING. CENTER STRAPS ON CJ
AND FILL ALL HOLES WITH 10d NAILS
NOTE:
1.(E) DECKING IS INSTALLED IN A STAGGERED 2 SPAN
CONFIGURATION.
BOUNDARY
NAILING = 10d
NAILS @ 4" OC
SPACE SHEATHING SO
THAT PANEL EDGES
FALL ON CENTER OF
DECK PIECE & NOT ON
A JOINT
(E) 3" TONGUE &
GROOVE DECKING
(E) GLULAM SUPPORT
BEAM BELOW
PANEL EDGE NAILING
= 10d @ 6" OC
FIELD NAILING
= 10d @ 12" OC
NEW 19/32" MIN
APA RATED
SHEATHING
ABOVE (E)
DECKING
PROVIDE #8x5" MIN EMBED WOOD
SCREW FROM DECKING TO
GLULAM AT DECKING MIDDLE
SUPPORT BEAM
(E) DECKING NAILS TO
GLULAMS, CONTRACTOR
TO VERIFY
NOTES:
1.MINIMUM EDGE DISTANCE FOR NAILS SHALL BE 3/8".
2.PROVIDE BOUNDARY NAILING (TYPE 4 ABOVE) INTO ALL SUPPORTING BEAMS,
WALLS, JOIST BLOCKING, AND RIM BOARDS UNO.
3.SEE PLAN HATCH REGION FOR AREAS REQUIREING ADDITIONAL UPLIFT NAILING.
1 8d @ 6" OC
2 8d @ 12" OC
3 8d @ 6" OC
2
1 PANEL EDGE NAILING AT SUPPORTED EDGES
2 FIELD NAILING
3 BOUNDARY NAILING
BEAM OR WALL
DIAPHRAGM EDGE
TRUSSES, RAFTERS
OR JOISTS
1
3
NAILING PATTERNS ARE THE SAME AS THOSE DESCRIBED IN IBC TABLE 2306.3.1. BLOCKED EDGES ARE NOT REQUIRED FOR LIGHTLY LOADED DIAPHRAGMS AND SHOULD BE AVOIDED IF POSSIBLE. ALL SHEATHING IS REQUIRED TO BE APA-RATED. APA RATINGS ARE BASED ON PERFORMANCE, NOT MATERIAL TYPE, SO FOR A GIVEN RATING, OSB AND PLYWOOD ARE EQUIVALENT IN TERMS OF STRUCTURAL PERFORMANCE. OSB IS CHEAPER AND WILL GENERALLY BE SELECTED BY THE CONTRACTOR IF PLYWOOD IS NOT SPECIFICALLY REQUIRED. PLYWOOD GENERALLY HOLDS UP BETTER TO WEATHER AND CONSTRUCTION TRAFFIC, AND MAY BE WORTH SPECIFYING IF THE SHEATHING WILL BE EXPOSED FOR LONG PERIODS DURING OR AFTER CONSTRUCTION. FLOOR SHEATHING SHOULD BE SPECIFIED USING APA'S "STURD-I-FLOOR" RATING SYSTEM (THIS IS A TONGUE-AND-GROOVE PRODUCT WITH A SINGLE NUMBER IN THE RATING, IE: 24OC). ROOF SHEATHING SHOULD BE SPECIFIED USING APA'S SPAN RATINGS (THIS IS A TWO NUMBER RATING, IE: 20/40). WHERE STRUCTURAL DECKING IS USED, SHEATHING IS FREQUENTLY PLACED DIRECTLY ABOVE IT TO ACT AS THE DIAPHRAGM. THIS CONDITION IS COVERED IN DETAIL 18/Z6.00xR.
3
PROVIDE 10d NAILS AT 4" OC
EACH DIRECTION FOR 3'
ADJACENT TO POP UP ROOF, FULL
LENGTH OF ROOF
SIMPSON LTT20B AT EACH GRIDLINE,
W/ (10) 10d NAILS TO VERTICAL
GLULAM THRU SHEATHING AND (1)
1/2"Øx8" LAG SCREW AND STD
WASHER TO GLULAM BEAM BELOW
2x8 W/ (2) #14x5" MIN EMBED WOOD
SCREWS TO EACH WALL STUD
SIMPSON A34 CLIP W/ (8) 8dx1 1/2"
NAILS @ EACH WALL STUD
PROVIDE 10d NAILS AT 4" OC EACH
DIRECTION FOR 3' ADJACENT TO
ROOF EDGE, FULL LENGTH OF
ROOF
PROVIDE 10d NAILS AT 4" OC EACH
DIRECTION FOR 3' ADJACENT TO
ROOF EDGE, FULL LENGTH OF
ROOF
2x8 W/ (3) #14x5" MIN EMBED WOOD
SCREWS TO EACH WALL STUD
SIMPSON A35 CLIP W/ (12) 8dx1 1/2"
NAILS @ 16" OC
(E) DECKING
2x8xCONT W/ (2) #14x5" MIN EMBED
WOOD SCREWS @ EACH WALL
STUD, PROVIDE CMST12x8'-0" AT
SPLICES
SIMPSON A44 W/ (8) 10d
NAILS @ EACH EXISTING
TRUSS
2x8 W/ (4) #14x5" WOOD
SCREWS @ 16" OC FOR
FIRST 12' NORTH OF
GRID EF
SIMPSON A44 W/ (8) 10d
NAILS @ EACH EXISTING
TRUSS. NAIL DIRECTLY
TO GLULAM WHEN 2x8 IS
NOT PRESENT
1 3/4" MIN
1/2"x4 1/2" SCREW ANCHOR @ 12" MAX,
8" MIN FOR 10' NORTH OF EB
AND 10' WEST OF E14 AT 'SIM'
REMOVE AND REPLACE EXISTING
PLYWOOD AS NECESSARY. NAIL
REPLACED PLYWOOD PER 11/S561
AT (E) MASONRY CONTROL JOINTS, PROVIDE
(2) SIMPSON CMST12x8'-0" STRAPS ON TOP
OF 2x10 BLOCKING. CENTER STRAPS ON CJ
AND FILL ALL HOLES WITH 10d NAILS
CONTRACTOR TO CONFIRM (3) MIN TOENAILS
FROM TRUSS TO SILL. PROVIDE NEW 8d NAILS
FOR ANY DEFICIT FOUND
REMOVE AND REPLACE (E)
SOLID BLOCKING AT 4'-0" OC IN
SPACE ADJACENT TO WALL
PROVIDE BOUNDARY
NAILS TO (E) MEMBERS
EACH SIDE OF WALL
SCALE:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJECT #:
0123456789101112
A
B
C
D
E
F
G
H
I
J
O H L S O N L A V O I E
C O L L A B O R A T I V E
www.olcdesigns.com
0123456789101112
SHEET #:
SHEET TITLE:
PR
I
N
C
I
P
A
L
:
EO
R
:
DE
S
I
G
N
E
R
:
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
MM
J
O
B
#
:
DA
T
E
P
R
I
N
T
E
D
:
FI
L
E
P
A
T
H
:
616 EAST SPEER BOULEVARD
DENVER, COLORADO
80203
T: 303.294.9244
F: 303.294.9440
NO. DATE: TITLE/PURPOSE:
6.
1.10-31-16 PERMIT SET
01-12-17 CONSTRUCTION DOCUMENTS
As indicated
5/
3
1
/
2
0
1
7
6
:
5
7
:
4
5
P
M
C:
\
P
r
o
j
\
1
6
.
0
1
1
7
.
S
.
0
1
-
E
S
T
E
S
_
C
O
M
M
U
N
I
T
Y
_
C
E
N
T
E
R
-
R
S
1
6_
e
s
a
b
i
a
.
r
v
t
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
SABIA
EAGAN
10-31-2016
16.0117.S.01
WOOD DETAILS
S561
66
0
C
O
M
M
U
N
I
T
Y
D
R
I
V
E
ES
T
E
S
P
A
R
K
,
C
O
ED
S
A
B
I
A
,
K
A
T
I
E
H
O
Y
T
ED
S
A
B
I
A
RA
L
P
H
R
E
M
P
E
L
16
.
0
1
1
7
.
S
.
0
1
DW
I
G
H
T
G
I
L
B
E
R
T
3/4" = 1'-0"3 MASONRY WALL TOP AT (E)
GLULAM 1 1/2" = 1'-0"7 NEW LVL TO (E) MAS WALL
1" = 1'-0"2 NEW LVL TO (E) STUD WALL
1 1/2" = 1'-0"1 NEW LVL TO (E) JOIST 1 1/2" = 1'-0"5 EXISTING GLULAM REINFORCING
1 1/2" = 1'-0"6 NEW LVL TO GLULAM
1 1/2" = 1'-0"8 NEW LVL TO (E) NORTH MASONRY WALL
BULLETIN NO. 088. 03-10-17
NO SCALE9 TYP HIGH ROOF SHEATHING
ABOVE (E) DECKING
WS1 19/32" THICK 32/16
APA-RATED PLYWOOD NO
MARK SHEATHING MATERIAL
BLOCKED
EDGES
FASTENER TYPE &
SPACING
HORIZONTAL DIAPHRAGM SCHEDULE
NO SCALE11 LOW ROOF HORIZONTAL
DIAPHRAGM SCHEDULE
3/4" = 1'-0"13 POPPED UP SECTION
ANCHORAGE
3/4" = 1'-0"14 TYP HIGH ROOF TO EXTERIOR
ROOF
3/4" = 1'-0"15 HIGH ROOF TO MAS WALL
3/4" = 1'-0"12 HIGH ROOF TO WALL - DECK
PERP
1" = 1'-0"17 LOW ROOF TO WALL AT GRID E13
1" = 1'-0"18 LOW ROOF TO WALL AT GRID E13
NORTH OF GRID EF
1 1/2" = 1'-0"16 LOW ROOF TO MAS WALL
PR 004- 05-01-17
1 1/2" = 1'-0"19 TYP LOW ROOF TO EXISTING
PARALLEL WALL
PR 004 REVISION 2- 06-01-17
OS S/DS
S
FAA
S
V
M
6'-8"
5'-4"
6'-0"
TO CENTER
(SEE NOTE 6)
1'-6"
3'-8"
TO BOTTOM OF DEVICE (SEE NOTE 4)
TOP OF CABINET
CENTER OF CABINET
TYPICAL 9'-0" CEILING
TYPICAL 8'-0" CEILING
8'-0"
7'-4"
TO CENTER
TO BOTTOM
5'-0"
TO CENTER
AC AC AC AC
POWER PANEL, FIRE
ALARM PANEL, OR
MASTER CLOCK
S
MDC
3
4
K
D
DOOR
TO
WS(x)
C
S
D
OS
OS
OS
WOS
TC
PC
HP
R
J
K
RA
F
FS
D
TS
S
TS
MH
S
M
T
M
T
M
V
S
SYSTEMS
DISTRIBUTION AND RACEWAY
FIRE ALARM
LIGHTING FIXTURES
WIRING DEVICES
ABBREVIATIONS AND SYMBOLS
FACP
FA-RPS
FAA
C
A
a
J
J
SR
x
x
x
x
x
x
x
A AMPERE(S)
AC ABOVE COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERES INTERRUPTING CAPACITY
ATS AUTOMATIC TRANSFER SWITCH
BFF BELOW FINISHED FLOOR
C CONDUIT
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CT CURRENT TRANSFORMER
DISC DISCONNECT
DW DISHWASHER
DWG(S) DRAWING(S)
(E) EXISTING TO REMAIN
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
(ER) EXISTING TO BE RELOCATED
EM EMERGENCY
EPO EMERGENCY POWER OFF
EWC ELECTRIC WATER COOLER
(R) EXISTING TO BE REMOVED
F FUSE
FLA FULL LOAD AMPS
FD GARBAGE DISPOSAL
G GROUND
GC GENERAL CONTRACTOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
HP HORSEPOWER
IDF INTERMEDIATE DISTRIBUTION FACILITY
IG ISOLATED GROUND
ISC SHORT CIRCUIT CURRENT
KVA KILOVOLT AMPERE(S)
KW KILOWATT(S)
LTG LIGHTING
MCA MINIMUM CIRCUIT AMPERE(S)
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION CENTER
MDF MAIN DISTRIBUTION FACILITY
MLO MAIN LUGS ONLY
MTS MANUAL TRANSFER SWITCH
MW MICROWAVE
NC NORMALLY CLOSED
NL NIGHT LIGHT - SEE GENERAL NOTES
NO NORMALLY OPEN
OAE OR APPROVED EQUAL
OH OVERHEAD
P POLE
PART PARTIAL CIRCUIT
PH PHASE
PNL PANEL
RCPT RECEPTACLE
REF REFRIGERATOR
(RL) RELOCATED
SPD SURGE PROTECTION DEVICE
UC UNDER COUNTER/CABINET
UG UNDERGROUND
UON UNLESS OTHERWISE NOTED
V VOLT(S)
W WATT(S) OR WIRE
WG WIRE GUARD
WP WEATHERPROOF
XFMR TRANSFORMER
POOL EQUIPMENT SCHEDULE NOTATION
KITCHEN EQUIPMENT SCHEDULE NOTATION
MECHANICAL EQUIPMENT SCHEDULE NOTATION
DETAIL NOTE
DELTA REVISION NOTE
ELECTRICAL WIRE SIZE
MAIN DISTRIBUTION CENTER (MDC)
SURFACE MTD PANELBOARD
RECESSED PANELBOARD
TRANSFORMER
BRANCH CIRCUIT HOMERUN
CONDUIT CONCEALED IN FLOOR OR UNDERGROUND
CONDUIT EXPOSED OR CONCEALED IN WALL OR
CEILING
RACEWAY UP
RACEWAY DOWN
CAPPED CONDUIT
CURRENT TRANSFORMER
CIRCUIT BREAKER SWITCH
FUSED SWITCH
GROUNDING ELECTRODE CONDUCTOR
METER
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR/GRAPHIC MAP
FIRE ALARM REMOTE POWER SUPPLY
CONTROL MODULE
MONITOR MODULE
MANUAL PULLDOWN STATION
WALL MOUNTED ADA STROBE
ADA HORN OR SPEAKER WITH STROBE
MINI HORN / STROBE
ELECTROMAGNETIC DOOR HOLD OPEN
SPRINKLER FLOW SWITCH
SPRINKLER TAMPER SWITCH
THERMAL DETECTOR
PHOTOELECTRIC SMOKE DETECTOR
DUCT SMOKE DETECTOR, SUPPLY OR RETURN
REMOTE INDICATING LIGHT (TEST SWITCH)
120V. MOTORIZED SMOKE DAMPER
RESCUE ASSISTANCE PHONE
FIRE FIGHTERS PHONE JACK
TTB, MDF OR IDF SYSTEM BACKBOARD
TELECOMMUNICATION OUTLET
FLOOR MOUNTED TELECOMMUNICATION OUTLET
TELEVISION OUTLET
SPEAKER - PAGING AND OR SOUND SYSTEM -
INDICATES SPEAKER ZONE
MICROPHONE OUTLET
VOLUME CONTROL
PUSH BUTTON
CLOSED CIRCUIT TELEVISION CAMERA
CABLE TRAY (LENGTH AS INDICATED ON DRAWINGS)
LUMINAIRE TYPE, REFERENCING LUMINAIRE
SCHEDULE, TYPICAL ALL FIXTURES. SUBSCRIPT,
IF SHOWN, REFERENCES WALL SWITCH.
WALL MOUNTED LUMINAIRE
SURFACE MOUNTED LUMINAIRE
RECESSED LUMINAIRE
DOWNLIGHT LUMINAIRE
SURFACE CEILING LUMINAIRE
PENDANT LUMINAIRE
WALLWASH LUMINAIRE
STRIP LUMINAIRE
SURFACE OR PENDANT TRACK LUMINAIRE
LINEAR PENDANT LUMINAIRE (LENGTH AS
INDICATED ON DRAWINGS/SCHEDULE)
EXIT LUMINAIRE - SHADED INDICATES FACE/
DIRECTIONAL ARROWS AS SHOWN.
BATTERY PACK EMERGENCY LUMINAIRE
EMERGENCY LUMINAIRE - SHADED PROVIDE WITH
INTEGRAL BATTERY BACKUP
PORCELAIN LAMP HOLDER
STEP LIGHT TYPE LUMINAIRE
BOLLARD OR POST TOP LUMINAIRE
EXTERIOR AREA LIGHT
DUPLEX RECEPTACLE
FOUR PLEX RECEPTACLE
SINGLE RECEPTACLE
COMBO RECEPTACLE/SWITCH
SWITCHED DUPLEX RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE
FLOOR MOUNTED RECEPTACLE DUPLEX/QUAD
SURFACE RACEWAY
CLOCK RECEPTACLE
JUNCTION BOX
WALL MOUNTED J-BOX
FLOOR MOUNTED JUNCTION BOX
MOLDED CASE CIRCUIT BREAKER IN ENCLOSURE
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MAGNETIC CONTROLLER (STARTER)
COMBINATION STARTER/DISCONNECT SWITCH
MOTOR
RELAY
TIME CLOCK
PHOTOCELL
THERMAL OVERLOAD SWITCH
SINGLE POLE SWITCH
3-WAY SWITCH
4-WAY SWITCH
KEY OPERATED SWITCH
DIMMER SWITCH
RECESSED DOOR SWITCH
LIGHTING CONTROL SYSTEM LOW VOLTAGE DIGITAL
WALL STATION. (X) INDICATES INDIVIDUAL WALL
STATION ADDRESS. REFER TO LIGHTING CONTROL
ONELINE DRAWING.
SINGLE RELAY OCCUPANCY SENSOR/SWITCH.
DOUBLE RELAY OCCUPANCY SENSOR/SWITCH.
CEILING MOUNTED OCCUPANCY SENSOR.
WALL MOUNTED OCCUPANCY SENSOR.
S
S
S
S
S
S
S
x CONTROL INTENT SCHEDULE NOTATION
x LIGHTING CONTROL DEVICE SCHEDULE NOTATION
TP TAMPER-PROOF
1. WHERE MULTIPLE LINE VOLTAGE DEVICES ARE SHOWN ADJACENT TO EACH OTHER, THEY ARE ALL TO
SHARE THE SAME JUNCTION BOX, UP TO FOUR GANGS.
2. WHERE MORE THAN FOUR DEVICES ARE SHOWN ADJACENT TO EACH OTHER, DEVICES ARE TO STACK
VERTICALLY ABOVE ONE ANOTHER IN TWO ROWS IN AS SMALL OF GANG BOXES AS POSSIBLE. I.E. SIX
DEVICES WILL USE TWO THREE GANG BOXES, FIVE DEVICES WILL USE ONE THREE GANG AND ONE TWO
GANG BOX.
3. SEPARATELY GANGED DEVICES ARE NOT ALLOWED TO BE INSTALLED ADJACENT TO ONE ANOTHER
HORIZONTALLY WITHIN THE SAME STUD BAY.
4. AUDIBLE/VISUAL FIRE ALARM DEVICES SHOWN ARE TO BE MOUNTED AT 90" OR 6" BELOW CEILING,
WHICHEVER IS LOWER. ADA STROBES TO BE MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS
LOWER.
5. MAXIMUM ELEVATION FOR ALL LOAD CENTER CIRCUIT BREAKERS SHALL NOT EXCEED 48" AFF, WITHIN
DWELLING UNITS.
6. THE E.C. SHALL REFER TO ARCHITECTURAL ELEVATIONS TO COORDINATE ALL COUNTER HEIGHTS. ALL "AC"
DEVICES SHALL HAVE BOTTOM OF BACK-BOX MOUNTED 4" ABOVE THE BACK/SIDE SPLASH.
NOTES:
AE
D
E
S
I
G
N
In
t
e
g
r
a
t
e
d
L
i
g
h
t
i
n
g
a
n
d
E
l
e
c
t
r
i
c
a
l
S
o
l
u
t
i
o
n
s
19
0
0
W
a
z
e
e
S
t
r
e
e
t
#
3
5
0
D
e
n
v
e
r
,
C
O
8
0
2
0
2
3
0
3
.
2
9
6
.
3
0
3
4
ae
d
e
s
i
g
n
-
i
n
c
.
c
o
m
IS
S
U
E
:
Copyright c 2013- All rights reserved
Architectural Engineering Design Group, Inc.
All design drawings and written m aterial
herein m ay not be used or duplicated
without the written consent of Architectural
Engineering Design Group, Inc.
IS
S
U
E
D
A
T
E
:
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
PR
O
J
E
C
T
#
:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
.
#
SHEET NO.:
SH
E
E
T
T
I
T
L
E
:
Pr
o
j
e
c
t
#
:
3
6
6
8
.
0
0
NT
S
E0.0
EL
E
C
T
R
I
C
A
L
CO
V
E
R
S
H
E
E
T
TP
K
,
S
K
VR
P
,
E
S
N
04
-
1
4
-
2
0
1
7
PR
0
0
4
/
A
L
T
1
P
E
R
M
I
T
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
660 COMMUNITY DRIVE ESTES PARK, CO
36
6
8
.
0
0
COVERSHEET NOTES
1 THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM.
2 MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES
HAVING JURISDICTION.
3 MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHER RECOGNIZED TESTING LAB.
4 ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT
COMPLIANCE WITH THE BUILDING STANDARDS, EXCEPT AS NOTED OTHERWISE.
5 THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER
EXECUTION AND COMPLETION OF THE ELECTRICAL WORK.
7 THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE,
UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
8 FOR ALL JOBS THAT INCLUDE DEMOLITION WORK BY THE ELECTRICAL CONTRACTOR, DURING AND AFTER DEMOLITION, EC SHALL MAINTAIN
CIRCUIT CONTINUITY TO ALL EXISTING DEVICES THAT ARE TO REMAIN. EC SHALL REMOVE, RELOCATE, AND/OR REWORK ANY CONDUIT AND
WIRING TO FACILITATE THE NEW CONSTRUCTION SCOPE OF WORK. FOR A LUMINAIRES THAT ARE EXISTING TO REMAIN OR EXISTING TO BE
RELOCATED, EC SHALL CLEAN LENSES AND REPLACE ALL EXTINGUISHED LAMPS, UON.
9 THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND THOROUGHLY BECOME FAMILIAR WITH THE
BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE
OBLIGATIONS OF THE CONTRACT.
10 ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN
SERVICE IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS.
11 ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR
IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE
DIRECTION OF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE.
12 SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY
BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES,
PARTIAL SUBMITTALS WILL NOT BE REVIEWED.
13 ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED.
14 DO NOT SHARE NEUTRAL CONDUCTORS FOR MULTIWIRE BRANCH CIRCUITS. WHERE THE E.C. PROPOSES THE USE OF SHARED NEUTRAL
CONDUCTORS OR SHARED NEUTRAL CONDUCTORS ARE REQUIRED (SUCH AS POWERED FURNITURE SYSTEMS), HANDLE TIES SHALL BE PROVIDED
ON THE CIRCUIT BREAKERS, WITH SHARED NEUTRALS, SUCH THAT IT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. ALL
HANDLE TIES ARE REQUIRED TO BE INDICATED ON THE PANELBOARD SHOP DRAWINGS.
15 SHOULD ACTUAL FIELD CONDITIONS REQUIRE INDICATED CIRCUIT DESIGNATIONS TO VARY, INDICATE THE CIRCUIT NUMBER USED ON THE
"AS-BUILT" DRAWINGS.
16 ALL SERVICE EQUIPMENT (OTHER THAN IN DWELLING UNITS) SHALL BE LEGIBLY MARKED IN THE FIELD BY THE ELECTRICAL CONTRACTOR WITH
THE MAXIMUM AVAILABLE FAULT CURRENT AS INDICATED WITHIN THESE DOCUMENTS. THE FIELD MARKING(S) SHALL COMPLY WITH ELECTRICAL
SPECIFICATIONS FOR READABILITY AND DURABILITY.
17 ALL NEW CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED.
18 ALL WIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE SHALL BE PLENUM RATED.
19 ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO ENCLOSE RECEPTACLES.
20 IN EXPOSED AND SUSPENDED CEILING APPLICATIONS, ROUTE CONDUIT AS CLOSE TO STRUCTURAL SLAB OR DECK AS POSSIBLE, AND SUPPORT
CONDUIT AND JUNCTION BOXES DIRECTLY FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH
CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE.
21 ALL EXPOSED CONDUIT SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE, AND SHALL BE INSTALLED PARALLEL AND CLOSE TO
STRUCTURAL MEMBERS. GENERAL CONTRACTOR SHALL PAIN CONDUIT TO MATCH ADJACENT FINISHES.
22 WHERE FLOOR FITTINGS REQUIRE PENETRATION OF THE FLOOR SLAB, THEY SHALL BE STANDARD DEVICE LISTED BY UL FOR THE PURPOSE AND
HAVE A UL FIRE RATING EQUAL TO THE FLOOR RATING. FLOOR SERVICE BOXES SHALL BE MODULAR, ADJUSTABLE FLUSH TYPE, DUAL SERVICE
UNITS SUITABLE FOR WIRING METHOD USED. COMPARTMENT BARRIERS SHALL SEPARATE POWER FROM LOW VOLTAGE CABLING. PROVIDE
RECTANGULAR SERVICE PLATE WITH SATIN FINISH.
23 ALL RECEPTACLES SHALL BE SPECIFICATION GRADE NEMA 5-20R, UNLESS OTHERWISE NOTED.
24 ALL LIGHT SWITCHES SHALL BE SPECIFICATION GRADE, QUIET OPERATION RATED 120/277 VOLT, 20 AMPS, UNLESS OTHERWISE NOTED.
25 ALL FACE PLATE AND DEVICE COLORS SHALL BE APPROVED BY ARCHITECT OR OWNER/LEASEE.
26 PROVIDE OWNER WITH A COMPLETE LISTING OF ALL FIXTURES UTILIZED ON THE PROJECT INCLUDING MANUFACTURER AND CATALOG
INFORMATION. PROVIDE A SUGGESTED SOURCE, INCLUDING CONTACT NAME AND PHONE NUMBER, FOR REORDERING.
27 ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST.
28 CONTRACTOR TO CONDUCT FUNCTIONAL TESTING OF LIGHTING CONTROLS EQUIPMENT AS REQUIRED BY IECC 2012/2015, SECTION C408.3. AFTER
THIS TESTING IS OBSERVED AND COMPLETED, THE REGISTERED DESIGN PROFESSIONAL OR COMMISSIONING AUTHORITY SHALL PROVIDE
DOCUMENTATION TO THE AHJ THAT CERTIFIES THAT THE INSTALLATION MEETS THE DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405.
NTS2DEVICE MOUNTING HEIGHT DIAGRAM
04/17/17
WS1
RC RC
EB
EC
ED
EE
EF
EXIST NATATORIUM
A110
EXIST POOL DECK
A109
H3
m H3
g H3
m H3
g H3
m H3
g H3
m H3
g H3
m H3
g H3
m
H4
g
H4
h
H3
n
H3
h
H3
n
H4
h
H4
n
H4
h
H4
n
H3
h
H3
n
H3
h
H3
n
H4
h
H4
g
1
POOL STORAGE
A108
EXIST POOL MECH
A112
EXIST POOL EQUIP
A114
4
1
1
1
1
1
5 0 .0 0 °
3
5
.
0
0
°
EH
NJ
5
EXIST ELEC
A113
'(E) L1'
'(E) H1'
RC2RC2
2
3
g,m h,n
H1-1,3 H1-5,7
AE
D
E
S
I
G
N
In
t
e
g
r
a
t
e
d
L
i
g
h
t
i
n
g
a
n
d
E
l
e
c
t
r
i
c
a
l
S
o
l
u
t
i
o
n
s
19
0
0
W
a
z
e
e
S
t
r
e
e
t
#
3
5
0
D
e
n
v
e
r
,
C
O
8
0
2
0
2
3
0
3
.
2
9
6
.
3
0
3
4
ae
d
e
s
i
g
n
-
i
n
c
.
c
o
m
IS
S
U
E
:
Copyright c 2013- All rights reserved
Architectural Engineering Design Group, Inc.
All design drawings and written m aterial
herein m ay not be used or duplicated
without the written consent of Architectural
Engineering Design Group, Inc.
IS
S
U
E
D
A
T
E
:
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
PR
O
J
E
C
T
#
:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
.
#
SHEET NO.:
SH
E
E
T
T
I
T
L
E
:
Pr
o
j
e
c
t
#
:
3
6
6
8
.
0
0
As
i
n
d
i
c
a
t
e
d
E1.0
EL
E
C
T
R
I
C
A
L
LI
G
H
T
I
N
G
P
L
A
N
TP
K
,
S
K
VR
P
,
E
S
N
04
-
1
4
-
2
0
1
7
PR
0
0
4
/
A
L
T
1
P
E
R
M
I
T
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
660 COMMUNITY DRIVE ESTES PARK, CO
36
6
8
.
0
0
1/8" = 1'-0"1 LAP POOL LIGHTING PLAN
LIGHT FIXTURE SCHEDULE
TYPE DESCRIPTION MANUFACTURER CATALOGUE NUMBER VOLTAGE
LAMP
QUAN.
LAMP
WATTAGE LAMP
MAX
WATTAGE DIMMING LOCATION
BOF/RFD/
OFH NOTES
H3 LED NATATORIUM
ARCHITECTURAL HIGH-BAY
LUX DYNAMICS LED-WAVE-3-UNV-TOP-835-(2)
HO-(1)SO-MH1P-LPDW-4'-NAT
UNIV 1 226 W LED 226 VA 0-10V SUSPENDED
CEILING
14'-0" BOF CUSTOM MODIFIED FIXTURE CONFIGURATION - PROVIDE 3-BAR FIXTURE WITH (1) STANDARD OUTPUT BAR AIMED DIRECTLY DOWN, (1) HIGH
OUTPUT BAR AIMED DIRECTLY TOWARD CENTER OF POOL, AND (1) HIGH OUTPUT BAR AIMED INDIRECTLY TOWARD CENTER OF CEILING.
COORDINATE EXACT BAR SPECIFICATION, LOCATIONS, AND AIMING WITH MANUFACTURER AND APPROVED SHOP DRAWINGS PRIOR TO PURCHASE.
EXACT FIXTURE AND LED BAR AIMING SHALL BE ADJUSTED IN-FIELD AS REQUIRED. COORDINATE CUSTOM SUSPENDED STEM LENGTH AT EACH
LOCATION PRIOR TO PURCHASE. PROVIDE INTEGRAL 0-10V PHOTOSENSOR PER FIXTURE CATALOGUE NUMBER AND PROVIDE UID8410 WIRELESS
REMOTE AS REQUIRED FOR SET POINT RE-PROGRAMMING AND COMMISIONING. INTEGRAL PHOTOSENSOR SHALL BE WIRED TO DIM (1)
HIGH-OUTPUT BAR/DRIVER AIMED DIRECTLY AT CENTER OF POOL IN ORDER TO MAINTAIN 50FC AT POOL.
H4 LED NATATORIUM
ARCHITECTURAL HIGH-BAY
LUX DYNAMICS LED-WAVE-3-UNV-TOP-835-(2)
HO-(1)SO-MH1P-LPDW-4'-NAT-
DLH 0-10V
UNIV 1 226 W LED 226 VA 0-10V SUSPENDED
CEILING
14'-0" BOF CUSTOM MODIFIED FIXTURE CONFIGURATION - PROVIDE 3-BAR FIXTURE WITH (1) STANDARD OUTPUT BAR AIMED DIRECTLY DOWN, (1) HIGH
OUTPUT BAR AIMED DIRECTLY TOWARD CENTER OF POOL, AND (1) HIGH OUTPUT BAR AIMED INDIRECTLY TOWARD CENTER OF CEILING.
COORDINATE EXACT BAR SPECIFICATION, LOCATIONS, AND AIMING WITH MANUFACTURER AND APPROVED SHOP DRAWINGS PRIOR TO PURCHASE.
EXACT FIXTURE AND LED BAR AIMING SHALL BE ADJUSTED IN-FIELD AS REQUIRED. COORDINATE CUSTOM SUSPENDED STEM LENGTH AT EACH
LOCATION PRIOR TO PURCHASE. PROVIDE INTEGRAL 0-10V PHOTOSENSOR PER FIXTURE CATALOGUE NUMBER AND PROVIDE UID8410 WIRELESS
REMOTE AS REQUIRED FOR SET POINT RE-PROGRAMMING AND COMMISIONING. INTEGRAL PHOTOSENSOR SHALL BE WIRED TO DIM (1)
HIGH-OUTPUT BAR/DRIVER AIMED DIRECTLY AT CENTER OF POOL IN ORDER TO MAINTAIN 50FC AT POOL.
KEYNOTE LEGEND
KEY
VALUE KEYNOTE TEXT
1 EXISTING SWITCHBANK LOCATION TO BE REMOVED AND REVISED PER NEW
CONTROLS SYSTEM.
2 NEW LIGHTING ROOM CONTROLLERS TO BE NETWORKED TO WATTSTOPPER
LIGHTING CONTROL SYSTEM RELAY PANEL TO BE INSTALLED IN NEW ELEC 254
UNDER SEPERATE BUILDING EXPANSION SCOPE OF WORK IN ORDER TO
ALLOW ALL CONTROLLER RELAYS/ZONES TO BE CONTROLLED VIA DIGITAL
WALLSTATION CONTROLS AND AUTOMATIC TIME-CLOCK. COORDINATE EXACT
REQUIREMENTS WITH APPROVED LIGHTING CONTROL SHOP DRAWINGS.
3 EC SHALL PROVIDE NEW WIRING FOR EXISTING CIRCUITS H-1,3,5,7 SERVING
EXISTING LAP POOL LIGHTING AND CONNECT THROUGH NEW ROOM
CONTROLLERS AND LIGHTING CONTROL SYSTEM AS INDICATED. EC SHALL
RE-USE EXISTING CONDUIT WHERE POSSIBLE AND EXTEND CONDUIT TO NEW
LOCATIONS AS REQUIRED.
4 PROVIDE WATTSTOPPER 4-BUTTON LOW-VOLTAGE SWITCH WITH 01-0V
DIMMING STATION FOR CONTROL OF LAP POOL LIGHTING VIA NEW ROOM
CONTROLLER RELAYS/ZONES. REFER TO LIGHTING CONTROL DIAGRAMS,
SHEET E2.0, FOR MORE INFORMATION. VERIFY EXACT LOCATION OF LIGHTING
CONTROL WALLSTATION WITH OWNER PRIOR TO PURCHASE.
GENERAL NOTES
A EXISTING SURFACE MOUNTED HID LIGHTING FIXTURES ARE TO BE REMOVED IN
THEIR ENTIRETY AND REPLACED WITH NEW FIXTURES AT SAME LOCATION AS
INDICATED. EXISTING LOCATIONS, CONDUIT, WIRING AND JUNCTION BOXES ARE
TO BE REUSED AS MUCH AS POSSIBLE. UPON REMOVAL OF EXISTING FIXTURES,
THE CONTRACTOR SHALL MAKE REPAIRS OF ANY VISIBLE DAMAGE TO THE
EXISTING CEILING AND CEILING FINISH AS NECESSARY. COORDINATE ANY
REQUIRED REPAIRS DIRECTLY WITH OWNER.
B UNLESS OTHERWISE NOTED, ALL FIXTURES ARE TO RE-USE EXISTING BRANCH
CIRCUITING FROM PANEL H1. EXISTING CIRCUITING SHALL BE REQUIRED TO
BE RE-CONNECTED VIA NEW LIGHTING CONTROLS AS INDICATED.
C EXISTING LIGHTING CONTROLS TO BE REMOVED AND REPLACED WITH NEW AS
INDICATED. REFER TO LIGHTING CONTROLS SCHEDULES AND DIAGRAMS,
SHEET E2.0, FOR MORE INFORMATION.
1/4" = 1'-0"3 ENLARGED PLAN EXISTING ELEC A113
ALL OTHER EXISTING DEVICES, EQUIPMENT, LIGHTING FIXTURES, OR OTHER
ELECTRICAL INSTALLATIONS NOT SHOWN SHALL REMAIN, UNLESS OTHERWISE
NOTED.
D
LIGHTING CONTROL DEVICES - LAP POOL
TYPE DESCRIPTION MANUFACTURER CATALOGUE PROGRAMMING REQUIREMENTS
RC2 DUAL RELAY ROOM CONTROLLER, SWITCHING WATTSTOPPER LMRC-112 ROOM CONTROLLER SHALL SWITCH FIXTURE
HIGH-OUTPUT DRIVER AS INDICATED. REFER TO
DETAIL NOTES, THIS SHEET, AND LIGHTING
CONTROL DIAGRAM, 3/E2.0, FOR MORE
INFORMATION
Co
n
s
t
r
u
c
t
i
o
n
Do
c
u
m
e
n
t
s
01
.
1
2
.
1
7
Re
v
i
s
i
o
n
1
0
5
.
3
1
.
1
7
1
E DURING COMMISSIONING PROCESS FOR LIGHTING CONTROLS SYSTEMS
PROVIDE LADDER OR OTHER ACCEPTABLE MEANS FOR COMMISSIONING AGENT
TO ACCESS ALL LIGHTING CONTROL SYSTEMS AND DEVICES AS REQUIRED.
COORDINATE EXACT TIMING AND ACCESS REQUIREMENTS WITH
COMMISSIONING AGENT PRIOR TO COMPLETION OF INSTALLATION.
1
EXISTING PANEL 'H1'
(E) LIGHTING
(E) FC - FAN COIL
(E) B - BOILER
--
--
(E) P1 - PUMP #1
--
--
(E) MP MAIN POOL PUMP
--
--
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
1
1
1
1
1
1
3
--
--
3
--
--
3
--
--
20
20
20
20
20
2
15
--
--
15
--
--
60
--
--
20
20
20
20
20
20
15
--
--
15
--
--
50
--
--
1
1
1
1
1
1
3
--
--
3
--
--
3
--
--
(E) LIGHTING
(E) EMERGENCY LIGHTING
(E) LIGHTING
(E) LOCKER RM LTG
SPARE
SPARE
(E) P5 - PUMP #5
--
--
(E) P1 - PUMP #1
--
--
(E) TRANSFORMER 'TL1'
--
--
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
CIR.
NO
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
CCT TYPE:
CCT TYPE:
LIGHTING:
RECEPTACLE:
MOTOR:
LGST MOTOR:
EQUIPMENT:
KITCH EQUIP:
SUBFEED PNL:
NOTES:
(*)
(**)
VOLTAGE L-L:
VOLTAGE L-N:
TYPE:
MOUNTING:
NOTES:
CCT
TYPE
L
L
L
L
OVER 10K:
NEW LIGHTING LOAD TO REPLACE EXISTING ON (E) CIRCUIT BREAKER. OVERALL LOAD ON CIRCUIT IS REDUCED FROM EXISTING.
OVERALL LOAD ON EXISTING PANEL 'H1' IS REDUCED FROM EXSITING. REFER TO LOAD SUMMARY FOR MORE INFORMATION
AND OVERALL PANEL LOAD JUSTIFICATION.
LOAD
VA
1356
1582
1356
1582
L=LIGHTING, R=RECEPTACLE, M=MOTOR, LM=LARGEST MOTOR, E=EQUIPMENT, KE=KITCH EQUIP, S=SUBFEED PANEL
LOAD
5876
0
0
0
0
0
0
0
480
277
3PH/4W
SURFACE
EXISTING
LOAD
DESCRIPTION
(N) POOL LIGHTING(*)
(N) POOL LIGHTING(*)
(N) POOL LIGHTING(*)
(N) POOL LIGHTING(*)
MULT
1.25
1.0
0.5
1.0
1.25
1.0
0
1.0
DEMANDED LOAD
7345
0
0
0
0
0
0
0
CIRCUIT BRKR
POLE
VA
VA
VA
VA
VA
VA
VA
VA
TRIP
LOCATION:
BUS RATING:
MAIN CB:
S.C. RATING:
FED FROM:
BUS
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
CIRCUIT BRKR
TRIP POLE
EXISTING ELEC A113
400
M.L.O.
14K AIC
(E) MDC
LOAD
DESCRIPTION
TOTAL CONNECTED LOADS
TOTAL DEMANDED LOADS
AMPS
VA
VA
AMPS
TOTAL ON
PANEL:
(EXISTING)
A
2938
A
3673
13
LOAD
VA
B
1582
B
1978
7
7
9
CCT
TYPE
C
1356
C
1695
6
KVA
AMPS(**)
CIR
NO
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
LOAD SUMMARY
EXISTING PANEL 'H1' (225A, 480/277V, 3PH, 4W)
EXISTING MAIN DISTRIBUTION CENTER 'MDC' (2000A, 480/277V, 3PH, 4W)
NOTES
EXISTING DEMAND LOAD ON PANEL 'H1'
TOTAL REMOVED LOAD ON PANEL 'H1'
TOTAL NEW LOAD ON PANEL 'H1'
TOTAL REMOVED LOAD ON PANEL 'H1'
(*)
(**)
1.
OVERALL LOAD ON EXISTING PANEL 'H1' IS REDUCED, THEREFORE FINAL TOTAL
LOAD ON (E) 175A BREAKER IS JUSTIFIED
OVERALL LOAD IS REDUCED, THEREFORE THE FINAL TOTAL LOAD IS JUSTIFIED
ON THE EXISTING 2000A MDC
EXISTING DEMAND LOADS FROM PREVIOUS ENGINEERS DRAWINGS
96.78
-10.40
7.35
TOTAL LOAD
AT 277/480V, 3PH
-3.06
TOTAL REMOVED LOAD
AT 277/480V, 3PH
KVA
KVA
KVA
KVA
116.40
-12.51
8.83
94
113
-3.67
-3
-4
AMPS
AMPS
AMPS
KVA
AMPS(*)
AMPS
KVA
AMPS (**)
Red
Yel
Lighting
Load
(1)
Lighting
Load
(2)
120/230/277
Hot Blk
Neutral Wht
LMRC-112
2-Zone Switching
Room Controller
RJ45 Port
(Typical)
LMSW-104 Scene Switch
g
m
h
n
To Additional Room Controllers
and/or Wattstopper Central Relay
Panel for Networked Timeclock
Functionality, as Required
LMRJ Series Pre-Terminated
Cables or CAT5e. Free
Topology
& Splitter Acceptable
T
2000N
TO UTILITY
PLATTE RIVER POWER AUTHORITY
(PRPA) PAD MOUNTED UTILITY
2000 KVA TRANSFORMER (ACTUAL
SIZE BASED UPON UTILITY
DISCRESION)
277/480V, 3 PH, 4W
(E) MAIN DISTRIBUTION CENTER (MDC)
2000A, 277/480V, 3PH, 4-WIRE, NEMA 1, 65KAIC RATED
M
GFP
2000A/3P
LSIG
(E)
N
G
(E) PRPA UTILITY NEMA
3R CONNECTION CT
CABINET & MAIN
SERVICE DISCONNECT
(MSD)
2000NG
SPD
10
0
A
/
3
P
PANEL
'HM2B'
225NG
T
XFMR
XFMR
PANEL
'LP2B'
'T2B'
112.5KVA
22
5
A
/
3
P
(E)
PANEL
'H1'
17
5
A
/
3
P
UPPER LEVEL
(E)
PEU
RTU
1
12
5
A
/
3
P
MECH
RTU
2
90
A
/
3
P
MECH
25
0
A
/
3
P
SP
A
C
E
10
0
A
/
3
P
SP
A
C
E
EX
T
E
R
I
O
R
RE
C
R
E
A
T
I
O
N
B
U
I
L
D
I
N
G
IN
T
E
R
I
O
R
T
XFMR
XFMR
PANEL
'LA2A'
'TAA'
30KVA
22
5
A
/
3
P
SP
A
R
E
GRADE
(E) PRPA ENERGY
METER
T
(E)
(E)
(E)
PANEL
'L1'
'TL1'
30KVA
(E)
PANEL
'H2'
10
0
A
/
3
P
T
(E)
(E)
(E)
PANEL
'L2'
'TL2'
30KVA
17
5
A
/
3
P
175NG 175NG 100NG
PANEL
'HA2A'
225NG
22
5
A
/
3
P
PANEL
'HM2A'
225NG
22
5
A
/
3
P
PANEL
'HL2B'
100NG
22
5
A
/
3
P
PANEL
'HM1B'
225NG
T
XFMR
XFMR
PANEL
'LP1B'
'T1B'
112.5KVA
10
0
A
/
3
P
10
0
A
/
3
P
PANEL
'HL1B'
100NG
T
XFMR
XFMR
PANEL
'LK1B'
'T1K'
30KVA
LOWER LEVEL
T
XFMR
XFMR
PANEL
'LP2A'
12
5
A
/
3
P
'TPA'
75KVA
1" CONDUIT
T
XFMR
XFMR
PANEL
'LT2B'
'TBT'
30KVA
RTU
3
17
5
A
/
3
P
MECH
10
0
A
/
3
25
0
A
/
3
P
SP
A
C
E
10
0
A
/
3
P
SP
A
C
E
ELEV
1
MECH
5#1, 2"C
(E) (E) (E) (E)
(E)
(E)
AE
D
E
S
I
G
N
In
t
e
g
r
a
t
e
d
L
i
g
h
t
i
n
g
a
n
d
E
l
e
c
t
r
i
c
a
l
S
o
l
u
t
i
o
n
s
19
0
0
W
a
z
e
e
S
t
r
e
e
t
#
3
5
0
D
e
n
v
e
r
,
C
O
8
0
2
0
2
3
0
3
.
2
9
6
.
3
0
3
4
ae
d
e
s
i
g
n
-
i
n
c
.
c
o
m
IS
S
U
E
:
Copyright c 2013- All rights reserved
Architectural Engineering Design Group, Inc.
All design drawings and written m aterial
herein m ay not be used or duplicated
without the written consent of Architectural
Engineering Design Group, Inc.
IS
S
U
E
D
A
T
E
:
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
PR
O
J
E
C
T
#
:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
.
#
SHEET NO.:
SH
E
E
T
T
I
T
L
E
:
Pr
o
j
e
c
t
#
:
3
6
6
8
.
0
0
NT
S
E2.0
ELECTRICAL
DETAILS
TP
K
,
S
K
VR
P
,
E
S
N
04
-
1
4
-
2
0
1
7
PR
0
0
4
/
A
L
T
1
P
E
R
M
I
T
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
660 COMMUNITY DRIVE ESTES PARK, CO
36
6
8
.
0
0
1/8" = 1'-0"3 LIGHTING CONTROL DIAGRAM
LIGHTING CONTROL DIAGRAM SHOWN FOR REFERENCE ONLY. COORDINATE
ACTUAL WIRING AND CONNECTION REQUIREMENTS WITH MANUFACTURER'S
APPROVED SUBMITTALS/SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS.
NTS4ELECTRICAL ONE-LINE DIAGRAM
ALL EQUIPMENT SHOWN ON ELECTRICAL ONE-LINE DIAGRAM IS EXISTING UNDER
PREVIOUS SCOPE OF WORK AND IS SHOWN FOR REFERENCE ONLY. NEW SCOPE OF
WORK SHALL INVOLVE BRANCH CIRCUITS AS NOTED ON LIGHTING PLAN, SHEET E1.0.
Co
n
s
t
r
u
c
t
i
o
n
Do
c
u
m
e
n
t
s
01
.
1
2
.
2
0
17
04/17/17
AE
D
E
S
I
G
N
In
t
e
g
r
a
t
e
d
L
i
g
h
t
i
n
g
a
n
d
E
l
e
c
t
r
i
c
a
l
S
o
l
u
t
i
o
n
s
19
0
0
W
a
z
e
e
S
t
r
e
e
t
#
3
5
0
D
e
n
v
e
r
,
C
O
8
0
2
0
2
3
0
3
.
2
9
6
.
3
0
3
4
ae
d
e
s
i
g
n
-
i
n
c
.
c
o
m
IS
S
U
E
:
Copyright c 2013- All rights reserved
Architectural Engineering Design Group, Inc.
All design drawings and written m aterial
herein m ay not be used or duplicated
without the written consent of Architectural
Engineering Design Group, Inc.
IS
S
U
E
D
A
T
E
:
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
PR
O
J
E
C
T
#
:
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
.
#
SHEET NO.:
SH
E
E
T
T
I
T
L
E
:
Pr
o
j
e
c
t
#
:
3
6
6
8
.
0
0
1
"
=
1
0
'
-
0
"
E3.0
ELECTRICAL
CODE
COMPLIANCE
FORMS
TP
K
,
S
K
VR
P
,
E
S
N
04
-
1
4
-
2
0
1
7
PR
0
0
4
/
A
L
T
1
P
E
R
M
I
T
ES
T
E
S
V
A
L
L
E
Y
C
O
M
M
U
N
I
T
Y
C
E
N
T
E
R
660 COMMUNITY DRIVE ESTES PARK, CO
36
6
8
.
0
0
04/17/17
SECTION 09 8400
ACOUSTICAL WALL TREATMENT
(CEMENTITIOUS WOOD FIBER WALL PANELS)
PART 1 GENERAL
1.01 SUMMARY
A. Section Includes: Cementitious wood fiber plank acoustical wall panel system and installation accessories.
1.02 REFERENCES
A. ASTM International:
1. ASTM C635 Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for
Acoustical Tile and Lay-in Panel Ceilings.
2. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials.
3. ASTM E1264 Standard Classification for Acoustical Ceiling Products.
B. Ceilings and Interior Systems Construction Association (CISCA):
1. CISCA Code of Practices.
1.03 SYSTEM DESCRIPTION
A. Performance Requirements:
1. Provide acoustical wall panel assembly designed and tested to provide surface burning characteristics (ASTM E84) as
follows:
a. Flamespread: 0.
b. Smoke Developed: 0.
2. Provide acoustical wall panel system which has been manufactured, fabricated and installed to provide Noise
Reduction Coefficient (NRC) rating as follows:
a. NRC rating minimum 0.40.
1.04 SUBMITTALS
A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures
Section.
B. Product Data: Submit manufacturer’s product data and installation instructions.
1. Recommended procedures for normal cleaning and removal of stains including precautions in use of cleaning
materials that may be detrimental to surfaces.
C. Samples: Submit selection and verification samples: [6 inch × 6 inch (152 × 152 mm) sample for each wall panel unit
required, showing full range of exposed texture to be expected in completed work] [And] [One 8 inch × 10 inch (203 × 254
mm) sample for each fabric color is available.].
D. Quality Assurance/Control Submittals: Submit the following:
1. Test Reports: Upon request, submit certified test reports from recognized test laboratories.
2. Certificates: Submit manufacturer’s certificate that products meet or exceed specified requirements.
1.05 QUALITY ASSURANCE
A. Installer Qualifications: Utilize an installer having demonstrated experience on projects of similar size and complexity.
B. Regulatory Requirements and Approvals: [Comply with requirements below.] [Specify applicable requirements of regulatory
agencies.].
1. International Code Council (ICC):
a. ICC-ES Evaluation Report ESR-1112.
1.06 DELIVERY, STORAGE & HANDLING
A. General: Comply with Division 1 Product Requirement Section.
B. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature
and humidity conditions recommended by the manufacturer.
1. Prevent soiling, physical damage or wetting.
2. Store cartons open at each end to stabilize moisture content and temperature.
1.07 PROJECT/SITE CONDITIONS
A. Environmental Requirements:
1. Do not install acoustical panels until building is closed in and HVAC system is operational.
2. Locate materials onsite at least 24 hours before beginning installation to allow materials to reach temperature and
moisture content equilibrium.
3. Maintain the following conditions in areas where acoustical materials are to be installed 24 hours before, during and
after installation:
a. Relative Humidity: 65 - 75%.
b. Uniform Temperature: 55 - 70 degrees F (13 - 21 degrees C).
1.08 MAINTENANCE
A. Extra Materials: Provide [A recommended percentage of] [Specify percentage.] additional material for use by owner in
building maintenance and repair.
B. Provide new unopened cartons of extra materials, packaged with protective covering for storage, identified with appropriate
labels.
PART 2 PRODUCTS
2.01 ACOUSTICAL WALL PANEL SYSTEM
A. Manufacturer: Tectum Inc.
1. Contact: 105 South Sixth Street, Newark, OH 43055; Telephone: (888) 977-9691, (740) 345-9691; Fax: (800) 832-
8869; E-mail: info@tectum.com; website: www.tectum.com.
B. Proprietary Systems. Acoustical Wall Panel systems, including the following:
Specifier Note: Retain one or more of the products below to suit project requirements.
1. Tectum Kerfed Wall Panels:
a. Material: Aspen wood fibers bonded with inorganic hydraulic cement.
b. Thickness: 1 inch (25.4 mm).
c. Edge: Long edge beveled.
d. Width: [23¾ inches (603 mm)].
e. Length 96 inches .
f. Color: [Natural]
g. Mounting Style: A. Plastic spline.
2.02 PRODUCT SUBSTITUTIONS
A. Substitutions: Section 01 6000 - Product Requirements.
2.03 ACCESSORIES
A. Provide accessories as follows:
1. Tectum Plastic Spline:
a. Material: Plastic.
2. Tectum Moulding:
a. Material: Plastic.
3. Tectum Touch-Up Paint:
a. Color: [Natural]].
PART 3 EXECUTION
3.01 MANUFACTURER’S INSTRUCTIONS
A. Comply with the instructions and recommendations of the acoustical wall panel system manufacturer.
B. Install materials in accordance with governing regulations, fire resistance rating requirements and industry standards
applicable to work.
1. Comply with CISCA Code of Practices.
3.02 EXAMINATION
A. Site Verification of Conditions:
1. Examine surfaces scheduled to receive suspended or directly attached acoustical units for unevenness, irregularities
and dampness that would affect quality and execution of work.
2. Do not proceed with installation of wall panel system until unacceptable conditions are corrected.
3.03 INSTALLATION
A. Screw head to be flush with panel surface.
B. Securely affix wall panels by means of splines attached vertically to smooth wall or furring strips. Engage vertical kerfs on
the edges of the wall panels with splines. Apply adhesive or use Velcro hook and loop fastening where necessary.
C. Cover field cut edges by means of trim or other moldings.
3.04 CLEANING
A. Clean exposed surfaces of acoustical panel, trim, moldings and suspension members to comply with manufacturer’s
instructions for cleaning.
B. Touch up any minor finish damage.
C. Remove and replace work that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage.
3.05 PROTECTION
A. Protect installed work from damage due to subsequent construction activity, including temperature and humidity limitations
and dust control, so that the work will be without damage and deterioration at the time of acceptance by the Owner.
END OF SECTION