Loading...
HomeMy WebLinkAboutPLANS 950 Comanche St Commercial Remodel 2021-05-29SHEET INDEX C0.0 COVER SHEET C0.1 CODE COMPLIANCE PLAN A1.0 BUILDING PLANS A2.0 FRONT ELEVATION GR O U P OD E S T O N E L DE S I G N LO D E S T O N E D E S I G N G R O U P 20 6 5 T H S T R E E T S U I T E 2 0 0 FR E D E R I C K , C O 8 0 5 3 0 PH O N E : 3 0 3 - 8 0 0 - 8 6 3 3 ma i l @ l o d e s t o n e d e s i g n . c o m ww w . L o d e s t o n e D e s i g n . c o m The Information shown on this document represents copyrighted intellectual property. Reproduction and/or distribution is not permitted without the prior consent of Lodestone Design Group. ISSUE RECORD DATE DRAWING TITLE: DATE: DRAWN: CHECKED: PROJECT #: - C0.0 COVER SHEET 05/29/2021 ARB SK Y R U N E S T E S P A R K 95 0 C O M A N C H E S T R E E T ES T E S P A R K , C O 8 0 5 1 7 JVS PERMIT 20-068 CO M M E R C I A L R E M O D E L PE R M I T SKYRUN ESTES PARK ESTES PARK, CO 80517 BUILDING DATAPROJECT TEAM Architect: Lodestone Design Group PO Box 440 206 Fifth Street Suite 200 Frederick, CO 80530-0440 P:303-800-8633 Contact: Jeff Van Sambeek # REVISION DATE 1. Do not scale these drawings. • Verify all dimensions and conditions prior to commencing work or ordering materials. • Any variation should be brought to the attention of the Owner and Architect. 2. Drawing Dimensions • All dimensions are to the face of the foundation and framing studs at new walls, or edge of rough opening unless noted otherwise. 3. Existing Conditions • It is the responsibility of the Contractor(s) to examine the existing conditions prior to submitting a bid to the Builder as proposals must take into account all such conditions which may affect the work. • Existing conditions are based on field measurement. • Discrepancies in the drawings and actual field conditions shall be reported to the Architect. Corrected drawings or instructions shall be issued by the Owner prior to the commencement of the work. 4. Code Compliance Town of Estes Park Building Department. • This project shall comply with current adopted codes including: • 2015 International Building Code • 2015 International Fuel Gas Code • 2015 International Plumbing Code • 2015 International Mechanical Code • 2015 International Energy Conservation Code • 2015 National Electrical Code • ICC/ANSI A117.1 -2009 • Estes Park Amendments to any of the above • It is the responsibility of anyone supplying labor, materials, or both to bring to the attention of the Architect and Builder any discrepancies or conflicts between requirements of these codes or standards and the drawings. 5. Utility Connections • Contractor shall coordinate and field verify utility connections, their routing, meter locations, hose bibs and other associated items. • No changes to existing utilities anticipated in proposed scope of work. 6. Manuals and Warranties • All manuals and warranties of all materials and equipment are to be furnished to the Owner upon completion of the project. 7. Completeness of Documentation • The details shown are intended to further illustrate the visual design concept and minimum weather protection requirements for this project. The Contractor(s) shall incorporate the requirements of the local building codes, structural considerations, trade association manuals, publications and recommendations and the manufacturer's written instructions for complete construction of details. All possible field conditions that may be encountered are not necessarily described. Field conditions encountered that require clarification shall be brought to the Builder's and Architect's attention. 8. Typical Wall Types • Existing exterior walls to remain throughout. Assumed to be 2X wood stud framed walls with batt. insulation in wall cavities. • New interior walls to be 2x4 wood stud framed walls @ 16" o.c. unless noted otherwise. Provide finished 5/8" gypsum wall board on all interior finished faces. • Finish wall board per owner. 9. Typical Doors and Windows • All existing windows to remain with no alterations. • Alterations or relocation of existing doors per exi sting/demo plan & elevation • All new interior doors to be hollow core; by owner. • All new exterior doors to have U-Factor of 0.32 or better; by owner 10. Heating, Ventilation, and Air Conditioning • Existing HVAC system to remain with any modifcations per Mechanical Plan. • Provide new ducting per Mechanical Plan. • Provide digital setback type thermostat. 11. Electrical • See Electrical plans for electrical outlet, switch, and fixture locations. 12. Plumbing • See mechanical for hookups and layouts. See architectural for basic plan layout. 13. GENERAL: • These plans and details have been designed for construction at one specific location. These plans and details shall not be used at any other building location. • Submit all shop drawings product information for Architect's and Owner's approval. GENERAL NOTES 5,981 SF PROJECT LOCATION Building Area: Main Floor: 5981 SF Tenant Finish Area: Main Floor: 2988 SF Existing Building Height:1 Story, approx. 14' -5" Occupancy:B-Business Construction Type:V-B Fire Sprinkler:None VICINITY MAP N Owner: SkyRun 1692 Big Thompson Ave. Suite 101 Estes Park, CO 80517 P:303-875-0277 Contact: Greg Rosner MEP Engineer: Reno James Engineering 3760 Vance Street Wheat Ridge, CO 80033 P:303-800-5105 RE F . DW 60 " M I N 18" MIN (a) FRONT APPROACH, PULL SIDE 12" MIN* 48 " M I N (b) FRONT APPROACH, PUSH SIDE * IF BOTH CLOSER AND LATCH ARE PROVIDED 60 " M I N 36" MIN (c) HINGE APPROACH, PULL SIDE 54 " M I N 42" MIN (d) HINGE APPROACH, PULL SIDE 42 " M I N * * 12" MIN* 22" MIN (e) HINGE APPROACH, PUSH SIDE * IF BOTH CLOSER AND LATCH ARE PROVIDED ** 48 MIN IF BOTH CLOSER AND LATCH ARE PROVIDED 48 " M I N * 24" MIN (f) LATCH APPROACH, PULL SIDE * 54 MIN IF CLOSER IS PROVIDED 42 " M I N * 24" MIN (f) LATCH APPROACH, PUSH SIDE * 48 MIN IF CLOSER IS PROVIDED Door Clearances 15" MIN5" MAX DRINKING FOUNTAIN SPOUT LOCATION 40 " M A X ACCESSIBLE MIRROR 56" MIN 60" MIN 16" - 18" ACCESSIBLE WATER CLOSET WATER CLOSET HEIGHT = 17-19" ABOVE FLOOR TO TOP OF SEAT OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA 33" - 36" 42" MIN 54" MIN 12" MAX WATER CLOSET SIDE WALL GRAB BAR 36" MIN 24" MIN 12" MIN REAR WALL GRAB BAR 24" MIN 42" MAX 18" MIN 1 1/2" MIN PROTRUDING DISPENSER BELOW GRAB BAR Plumbing Elements and Facilities 18" MIN 39" - 41" 33" - 36" 39" - 41". 34" MAX SINK AND COUNTER HEIGHT 36" MAX 38 - 43". 15" MIN 5" MAX PLANELEVATION WHEELCHAIR ACCESIBLE STANDING PERSONS 6 0 " M I N (a) CIRCULAR TURNING SPACE 12" MIN 36" MIN 12" MIN 24" MIN 60" MIN 36" MIN 60" MIN (b) T-SHAPED TURNING SPACE 48" MIN 30" MIN CLEAR FLOOR SPACE 30" MIN 17" - 25" TOE AND KNEE CLEARANCE Space Clearances 6" MAX 9" TOE CLEARANCE KNEE CLEARANCE 11" MIN 27" MIN 8" MIN 9" 2988 SF TENANT AREA DI S T A N C E T O E X I T : 8 6 ' -0" 2993 SF Area EXIT EXIT EXIT GR O U P OD E S T O N E L DE S I G N LO D E S T O N E D E S I G N G R O U P 20 6 5 T H S T R E E T S U I T E 2 0 0 FR E D E R I C K , C O 8 0 5 3 0 PH O N E : 3 0 3 - 8 0 0 - 8 6 3 3 ma i l @ l o d e s t o n e d e s i g n . c o m ww w . L o d e s t o n e D e s i g n . c o m The Information shown on this document represents copyrighted intellectual property. Reproduction and/or distribution is not permitted without the prior consent of Lodestone Design Group. ISSUE RECORD DATE DRAWING TITLE: DATE: DRAWN: CHECKED: PROJECT #: - C0.1 CODE COMPLIANCE PLAN 05/29/2021 ARB SK Y R U N E S T E S P A R K 95 0 C O M A N C H E S T R E E T ES T E S P A R K , C O 8 0 5 1 7 Checker PERMIT 20-068 CO M M E R C I A L R E M O D E L PE R M I T # REVISION DATE BUILDING DATA Construction Type:V-B Occupancy Type:Non-separated mixed use. All uses currently B or M occupancies Controlled by B (identical to M for height and area) Fire Suppression:NS Fire Alarm:None Total Building Area:5,981 SF CODE COMPLIANCE:2015 IBC Building Height (Full Building):~14'-5" (40' maximum per table 504.3) 1 Story (2 Story maximum per table 504.4) Building Area (Full Building):5,981 SF (9,000 SF maximum per floor per table 506.2) Tenant Area:2,988 SF Occupant Load (Tenant Area) @ 1:100:29.88 = 30 occupants (per Table 1004.5) Exiting: Number of Exits: 3 provided at 36" wide each (1 required per Table 1006.2.1) Exit Access Travel Distance:86'-0" (100' maximum per Table 1006.2.1) Dead-End Corridor:N/A for single exit occupancies Plumbing Fixture Requirements:(per Table 2902.1) Separate Facilities required per 2902.2 Fixture Type: Factor: Required: Provided: Toilet 1:25 1.20 2 Lavatory 1:40 0.75 2 Drinking Fountain: 1:100 0.30 1 Service Sink: 1 1 CODE ANALYSIS SCALE:1/4" = 1'-0" ADA DOOR CLEARANCE SCALE:1/4" = 1'-0" ADA PLUMBING CLEARANCES SCALE:1/4" = 1'-0" ADA SPACE CLEARANCES SCALE:1/8" = 1'-0"1 CODE ANALYSIS PLAN RE F . DW 98 ' - 8 1 / 8 " 29 ' - 5 5 / 8 " 69 ' - 2 1 / 2 " 28' - 8 3/8" 28' - 8 3/8" EXISTING DOOR TO BE REPLACED; FLIP SWING EXISTING EXTERIOR WALLS TO REMAIN, TYP. EXISTING DEMISING WALL TO REMAIN EXISTING MECHANICAL ROOM TO REMAIN EXISTING INTERIOR WALLS TO BE DEMOLISHED, TYP. EXISTING WINDOWS TO REMAIN, TYP. EXISTING RESTROOMS TO BE DEMOLISHED, TYP. EXISTING INTERIOR DOORS TO BE DEMOLISHED, TYP. EXISTING OVERHEAD DOOR TO BE DEMOLISHED; WALL & NEW EXTERIOR DOOR OPENING TO BE RE-FRAMED EXISTING EXTERIOR DOOR TO BE DEMOLISHED; WALL TO BE RE-FRAMED EXISTING WATER METER TO REMAIN CONFERENCE ROOM 12'-0" X 24'-0" BREAK ROOM 11'-0" X 18'-0" RESTROOM 6'-6" X 7'-6" RESTROOM 6'-6" X 7'-6" CUSTOMER CONFERENCE 8'-0" X 9'-4" LOBBY/ RECEPTION 8'-0" X 10'-0" MANAGER'S OFFICE 11'-10" X 11'-6" FILE/COPY 6'-0" X 8'-2" 11 ' - 9 1 / 2 " 23 ' - 1 " 9' - 1 0 5 / 8 " 20 ' - 4 " 18 ' - 3 1 / 2 " 7' - 9 1 / 2 " 7' - 6 " 98 ' - 8 1 / 8 " 16' - 10 3/8"11' - 10" 28' - 8 3/8" 9' - 3 1 / 2 " 24 ' - 3 1 / 2 " 13 ' - 7 1 / 2 " 9' - 7 1 / 2 " 10 ' - 3 1 / 2 " 31 ' - 6 1 / 2 " EQ EQ EQ EQ EQ 6' - 9 " 1' - 4 " 1' - 4 " 22' - 2 3/8"6' - 6" 28' - 8 3/8" 12' - 3 1/2"9' - 7 3/8" 12' - 3 1/2"5' - 1 3/8"11' - 3 1/2" 8' - 3 1/2"5' - 7 7/8"7' - 6"7' - 3" 3' - 5"3' - 10" 7' - 4 1 / 2 " 7' - 3 " 7' - 3 " 7' - 4 1 / 2 " 7' - 1 1 / 2 " 7' - 4 1 / 2 " 9' - 4 1 / 2 " 7' - 3 " 7' - 3 " 7' - 4 1 / 2 " 9' - 0 " I N T E R I O R 7' - 0 " T Y P . IN T E R I O R 7' - 0" TYP. INTERIOR 9' - 0 3/8" 28 ' - 1 1 1 / 8 " 69 ' - 9 " 15 " MI N . 5" MA X . UTILITY SINK 103 102 109 E E 101 100 104 105 107 108 106 E E E E E OFFICE CUBE PANELS & DESKS BY OWNER, TYP. ADA COMPLIANT DUAL HT. DRINKING FOUNTAIN 6' - 7 7/8"7' - 3"7' - 4 1/2" EXISTING WATER METER TO REMAIN 4' LINEAR LED PENDANT LIGHT FIXTURE BY OWNER, TYP. 8' LINEAR LED PENDANT LIGHT FIXTURE BY OWNER, TYP. GR O U P OD E S T O N E L DE S I G N LO D E S T O N E D E S I G N G R O U P 20 6 5 T H S T R E E T S U I T E 2 0 0 FR E D E R I C K , C O 8 0 5 3 0 PH O N E : 3 0 3 - 8 0 0 - 8 6 3 3 ma i l @ l o d e s t o n e d e s i g n . c o m ww w . L o d e s t o n e D e s i g n . c o m The Information shown on this document represents copyrighted intellectual property. Reproduction and/or distribution is not permitted without the prior consent of Lodestone Design Group. ISSUE RECORD DATE DRAWING TITLE: DATE: DRAWN:CHECKED: PROJECT #: - A1.0 BUILDING PLANS 05/29/2021 ARB SK Y R U N E S T E S P A R K 95 0 C O M A N C H E S T R E E T ES T E S P A R K , C O 8 0 5 1 7 Checker PERMIT 20-068 CO M M E R C I A L R E M O D E L PE R M I T # REVISION DATE SCALE:3/16" = 1'-0"1 EXISTING/DEMO PLAN SCALE:3/16" = 1'-0"2 MAIN LEVEL REMODEL PLAN N DOOR SCHEDULE Mark Width Height Description 100 3' - 0" 6' - 8" SINGLE EXTERIOR DOOR; HALF LITE; U-FACTOR 0.32 OR BETTER 101 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 102 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 103 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 104 6' - 0" 6' - 8" DOUBLE INTERIOR DOOR 105 3' - 0" 6' - 8" FRAMED OPENING 106 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 107 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 108 3' - 0" 6' - 8" SINGLE INTERIOR DOOR 109 3' - 0" 6' - 8" SINGLE EXTERIOR DOOR; FULL LITE; U-FACTOR 0.32 OR BETTER **NOTE: ALL DOORS AND WINDOWS MARKED 'E' ARE EXISTI NG TO REMAIN SCALE:3/16" = 1'-0"3 MAIN LEVEL LIGHTING LAYOUT T.O. MAIN LEVEL SUBFLOOR 99' -9 1/4" EXISTING CEILING HEIGHT 109' -11" ROOF HEIGHT 114' -1 5/8" DECORATIVE TIMBER COLUMNS, TYP. DECORATIVE TIMBER BEAM EXISTING ROOF TO REMAIN EXISTING SIDING TO REMAIN 109 E 100 EE REMOVE EXISTING OVERHEAD DOOR; NEW DOOR AND SIDING TO MATCH EXISTING REMOVE EXISTING DOOR & OPENING; NEW SIDING TO MATCH EXISTING SCALE:3/8" = 1'-0"1 WEST/FRONT ELEVATION GR O U P OD E S T O N E L DE S I G N LO D E S T O N E D E S I G N G R O U P 20 6 5 T H S T R E E T S U I T E 2 0 0 FR E D E R I C K , C O 8 0 5 3 0 PH O N E : 3 0 3 - 8 0 0 - 8 6 3 3 ma i l @ l o d e s t o n e d e s i g n . c o m ww w . L o d e s t o n e D e s i g n . c o m The Information shown on this document represents copyrighted intellectual property. Reproduction and/or distribution is not permitted without the prior consent of Lodestone Design Group. ISSUE RECORD DATE DRAWING TITLE: DATE: DRAWN: CHECKED: PROJECT #: - A2.0 FRONT ELEVATION 05/29/2021 ARB SK Y R U N E S T E S P A R K 95 0 C O M A N C H E S T R E E T ES T E S P A R K , C O 8 0 5 1 7 Checker PERMIT 20-068 CO M M E R C I A L R E M O D E L PE R M I T # REVISION DATE