HomeMy WebLinkAboutREPORT Asbestos Inspection 1851 Wildfire Rd 2022-10-18SilverK
Services
Asbestos Inspection and Sampling Report
1851 Wildfire Rd. Estes Park., CO 80517
Presented To:
Westover Construction
1789 Wildfire Rd.
Estes Park, CO 80517
Performed & Prepared By:
Thomas Cartmell
SilverKey Services
P.O. Box 2641
Loveland, CO. 80539
Phone: 970-215-1874
ceartmell@silverkeyservice.corn
Project Details:
Project Number: B2214275
Conducted; October 18ih 2022
1 1 Page
PROJECT OVERVIEW
lA Introduction
On October 18'h 2022, Thomas Cartmell with SilverKey Services conducted a limited asbestos
inspection and collected asbestos hulk -samples of suspect asbestos -containing materials (ACM)
within a portion of the residence located at 1851 Wildfire Rd. Estes Park, CO 80517.
The purpose of the limited inspection was to identify and sample potentially hazardous friable and
non -friable ACM that has either been affected by a recent full scrape and/or may be impacted by
subsequent restoration activities.
2.0 Scope of Work
The scope of the limited inspection and bulk -sampling was limited to specific areas of the residence
defined by the contractor. The following areas include: the Southeast bedroom, Northeast bedroom,
kitchen, bathroom, living room, upstairs loft, basement, roofing, garage, and the exterior rock. The
suspect materials being tested include: Drywall, texture, joint compound, flooring material,
caulking, roofing paper, and shingles. The remaining areas within the residence, garage or any
outbuilding on the property were not included in the scope of the inspection. The limited asbestos
inspection did not constitute a full building inspection and does not fulfill the asbestos inspection
requirements for structures that are to he demolished.
3.0 Site Description
Single Family Residence
4.0 Certifications
The limited asbestos inspection and bulk -sampling was conducted by Thomas Cartmell with
SilverKey Services. Thomas Cartmell is a Colorado Department of Public Health and Environment.
(CDPHE) certified Building Inspector; having certification number 26919.
5.0 Inspection, Sampling & Analytical Procedures
5.1 Inspection Procedures
The limited asbestos inspection was conducted by an Environmental Protection Agency (EPA) and
CDPHE certified Building Inspector. The inspection procedures included identifying and sampling
suspect ACM within the pre -defined areas, submitting samples to an accredited laboratory for
analysis, classifying the materials and assessing their condition, and compiling a final report
detailing the inspection and the analytical results of the bulk -samples.
P age
6.2 Material Classifications
Sampled materials are divided into one of the following three categories:.
• Surfacing Material: sprayed or troweled onto structural building members
• Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation
• Miscellaneous Material: all other materials not classified in the above two categories
6.3 Material Conditions
Sampled materials are placed into one of the three following categories of conditions:
• Good: none to very little visible damage or deterioration
• Damaged: the surface is crumbling, blistered, water -stained, gouged, marred or otherwise
abraded over less than one -tenth of the surface if the damage is evenly distributed, or one -quarter if
the damage is localized
• Significantly Damaged: the surface is crumbling, blistered, water -stained, gouged, marred or
otherwise abraded over greater than one -tenth of the surface if the damage is evenly distributed, or
one -quarter if the damage is localized.
6.4 Sample Quantities
SilverKey Services collected at least the minimum number of samples from each homogeneous area
necessary to meet all regulatory requirements for the quantity of material to be disturbed. The
quantities listed in this report are approximate and on -site verification of the exact quantity of each
material is required. The following outlines the minimum sample quantities required per
homogeneous area:
• Surfacing Materials: up to 1,000 ft2 of material requires a minimum of three (3) samples; between
1,000 ft2 and 5,000 ft2 of material requires a minimum of five (5) samples; over
5,000 ft2 of material requires a minimum of seven (7) samples; one (1) sample of each patch
• Thermal System Insulation (TSI): each homogeneous area requires a minimum of three (3)
samples; at least one (1) sample must be collected from each patch; and collect enough samples
sufficient to adequately assess the material and determine the asbestos content for TSI fittings such
as pipe elbows or T's.
• Miscellaneous Materials: collect enough samples sufficient to determine the asbestos Content
7. Overview of Finding
Asbestos was not reported within some of one or more of the samples collected. Therefore,
abatement of these materials will not be required. SilverKey Services collected a total of (50)
asbestos bulk -samples of (22) homogeneous areas.
Table 1 below describes the materials composing each homogeneous area as well as the locations of
each bulk sample collected. Also listed is the classification, condition, friability and estimated
quantity of material to be removed and/or disturbed, as well as the asbestos content within each
bulk -sample. Please see Appendix B: Analytical Data for the layer break -down of each bulk -sample.
51fage
HOMOGENEOUS SAMPLING AREA: HA4
MATERIAL DESCRIPTION: Joint compound/drywall
COLOR: White
PATTERN: NA
QUANTITY: 50 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Bathroom Southwest corner wall, bathroom Southeast corner wall
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA4-009, HA4-010
RESULT: ND
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA: HA5
MATERIAL DESCRIPTION: Surfacing material
COLOR: White
PATTERN: Orange peel
QUANTITY: 1,000 sq ft
CONDITION: G
MATERIAL CATEGORY: SM
LOCATION: Southeast bedroom North wall, Northeast bedroom. West wall, kitchen North wall,
living room South wall, upstairs loft South wall
# OF SAMPLES TAKEN: 5
SAMPLE ID NUMBER(S): HA5-011, HA5-012, HAS-013, HAS-014, 1-1A5-01.5
RESULT: N D
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA: HA6
MATERIAL DESCRIPTION: Joint compound/drywall
COLOR: White
PATTERN: NA
QUANTITY.: 1,000 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Upstairs loft Northwest corner wall, kitchen Southwest corner wall
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA6-016, 1-IA6-017
RESULT: ND
FRIABILITY: Friable
7 I Page
HOMOGENEOUS SAMPLING AREA: HA10
MATERIAL DESCRIPTION: Mastic
COLOR: Yellow
PATTERN: NA
QUANTITY: 50 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Bathroom vinyl flooring
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA10-024, HA10-025
RESULT: ND
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA: HA11
MATERIAL DESCRIPTION: Caulking
COLOR: White
PATTERN: NA
QUANTITY: 25 LF
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Kitchen counter, bathroom counter
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA11-026, HA11-027
RESULT: ND
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA: I-1A 12
MATERIAL DESCRIPTION: Mastic
COLOR: Blue
PATTERN: NA
QUANTITY: 600 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Basement wood paneling
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HAl2-028, HAl2-029
RESULT: ND
FRIABILITY.: Friable
9WPa e
HOMOGENEOUS SAMPLING AREA: HA16
MATERIAL DESCRIPTION: Caulking
COLOR: Brown
PATTERN: NA.
QUANTITY: NA
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Window
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA16-037, HA16-038
RESULT: ND
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA; HA17
MATERIAL DESCRIPTION: Drywall
COLOR: Pink, tan
PATTERN: NA
QUANTITY: NA
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Garage ceiling
## OF SAMPLES TAKEN; 2
SAMPLE ID NUMBER(S): HA17-039, HA17-040
RESULT: ND
FRIABILITY: Friable
HOMOGENEOUS SAMPLING AREA: HA18
MATERIAL DESCRIPTION: Shingles
COLOR: Black, tan
PATTERN; NA
QUANTITY: 1,000 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Garage
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMBER(S): HA18-041, HA18-042
RESULT: ND
FRIABILITY. Friable
1
HOMOGENEOUS SAMPLING AREA: HA22
MATERIAL DESCRIPTION: Mortar
COLOR: Gray
PATTERN: NA
QUANTITY: 500 sq ft
CONDITION: G
MATERIAL CATEGORY: MM
LOCATION: Exterior rock
# OF SAMPLES TAKEN: 2
SAMPLE ID NUMi ER(S): HA22-04-9, HA22-050
RESULT: ND
FRIABILITY: Friable
ND -Non -detect
HA- Homogenous Area
TR-Trace, <1%
D-Damaged MM-Miscellaneous Material
G-Good SM-Surfacing Material
SD -Significantly Damage TSl-Thermal System Insulation
It is the responsibility of the asbestos abatement company to give cr scope of work for all
abatement.
8. Findings & Recommendations
ACM was not identified within the following areas: the Southeast bedroom ceiling surfacing
material, Northeast bedroom ceiling surfacing material, kitchen ceiling surfacing material, kitchen
North corner ceiling joint compound/drywall, bathroom West corner ceiling joint
compound/drywall, bathroom West wall surfacing material, bathroom South wall surfacing
material, bathroom East wall surfacing material, bathroom Southwest corner wall joint
compound/drywall, bathroom Southeast corner wall joint compound/drywall, Southeast bedroom
North wall surfacing material, Northeast bedroom West wall surfacing material, kitchen North wall
surfacing material, living room South wall surfacing material, upstairs loft South wally surfacing
material, upstairs loft Northwest corner wall joint compound/drywall, kitchen Southwest corner
wall joint compound/drywall, kitchen vinyl flooring or mastic, bathroom vinyl flooring or mastic,
kitchen counter caulking, bathroom counter caulking, basement wood paneling or mastic, basement
ceiling surfacing material, basement North ceiling corner joint compound/drywall, roofing shingles
paper, window caulking, garage ceiling drywall, garage shingles, roofing shingles paper, garage
roofing vent caulking, exterior plaster, or the exterior rock mortar that were within the scope of the
limited inspection and bulk -sampling performed on October 18,1' 2022; therefore, professional
abatement activities arc not required to remove or disturb the above -reference sampled materials.
ACM was not impacted or disturbed. We do not consider this a spill; SilverKey Services
recommends that when ACM is removed/abated, that only a licensed asbestos abatement
contractor using personnel trained in the handling of ACM be allowed to conduct such activities
using appropriate methods (HEPA- filtered vacuuming, wet cleaning methods,respiratory
protection, protective clothing, personnel decontamination, negative -air enclosures, air monitoring,
etc.).
For all spills, SilverKey Services recommends that all soft goods (carpet, pad, clothes, couches, etc.)
and any ceiling and/or wall surfacing restoration activities be removed from the interior of the
building as asbestos waste. SilverKey Services also advises that only hard surfaces (plastic, metal,
wood, concrete, etc.) are allowed to be left in place before the final visual and final air clearance
13 I Page
Microvacuum samples must be collected and analyzed in accordance with the procedures
specified in the ASTM International Method D5755-09 (Reapproved April 2014), "Standard Test
Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron
Microscopy for Asbestos Structure Number Surface Loading."
Wipe samples must be collected and analyzed in accordance with the procedures specified in the
ASTM International Method D6480-19 (January 2019), "Standard Test Method for Wipe Sampling
of Surfaces, Indirect Preparation, and Analysis for Asbestos Structure Number Surface Loading by
Transrission Electron Microscopy."
• The General Abatement Contractor (GAG) selected to perform the cleanup of the spill must:
Submit notification in accordance with subsection III.E. (Notifications) or subsection III.G.
(Permits), whichever is applicable to the Division for approval.
• Using certified Supervisors and certified Workers in accordance with section II. (Certification.
Requirements), construct a containment in accordance with the following mandatory subsections,
which must be followed in the exact sequence shown:
Construct the decontamination unit in accordance with subsection Il1.K. (Decontamination Unit).
Install critical barriers in accordance with subsection 111.1. (Critical Barrier installation)
Comply with the requirements of subsection lll.l. (Air Cleaning and Negative Pressure
Requirements)
HEPA vacuum or steam clean all carpets, drapes, upholstery, and other non -clothing fabrics in the
contaminated area, or discard these materials in accordance with subsection III.R. (Waste
handling)
Launder or discard all contaminated clothing in accordance with subsection. III.R. (Waste
Handling).
HEPA vacuum or wet wipe with clean
area.
ended water on a l hard surfaces in the contaminated
Discard all waste in accordance with subsection III.R. (Waste Handling).
Ensure items cleaned as part of the spill response are included in the clearance process.
• All persons must comply with any other measures, provided in wriling by the Division, which are
deemed necessary to protect public health.
• Following completion of Sections 111.T.2_d.(i) through II1.T.2.e., the AMS must comply with air
monitoring requirements as described in Section II LP. (Clearing Abatement Projects); air samples.
must be collected aggressively as described in 40 C.P.R. Part 763, Appendix A to Subpart E (EPA
2010), except that the air stream of the leaf blower must not be directed at any friable ACM that
remains in the area.
5 1 Page
10.0 Disclaimer 8, Limitations
The activities outlined in this report were conducted in a manner consistent with a level of care and
expertise exercised by members of the environmental consulting and industrial hygiene profession.
All activities were performed in accordance with all applicable federal, state, and local regulations
as well as generally accepted standards and professional practice. No warranty is either expressed.
or implied. SilverKey Services assumes no responsibility or liability For error in public information
utilized, statements from sources other than. SilverKey Services, or developments resulting from
situations outside the scope of this project.
The details provided within this report outline the inspection activities on the date(s) indicated and
should not be relied upon to represent conditions at a later date, the limited number of bulk
samples collected, and the laboratory results of those bulk -samples. The laboratory results
contained in this report apply specifically to the materials in which bulk -samples were collected.
The results do not include or apply to any other materials within the structure that were not
sampled, but may contain asbestos; including materials that may be hidden or inaccessible.
Additional inspection and bulk -sampling activities would be required to determine if any other
materials contain asbestos. This report has been prepared on behalf of and exclusively for use by
the Client, with specific application to their project as discussed in the scope of work. The results of
any surfacing material indicated in this report also includes any associated overspray of that
material, e.g., under carpet, above suspended ceilings, etc. The information contained in this report
is intended as supplementary material for abatement design and is not to be used as the scope of
work for abatement activities, bidding or billing purposes. Contractors or consultants reviewing
this report must draw their own conclusions regarding further investigation or remediation
deemed necessary.
Thank you for your business.
Sincerely,
Thomas Cartmell
State of Colorado Building Inspector Accreditation No: 26919 Exp. 6/21/2023
SilverKey Services Asbestos Consulting Firm Registration No: ACF-23285
17 I Page
19 I Page
21 V Page
23 I Page
25 1 Page
e
rorins
ASB STOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
SilverKey Services, LLC
CLIENT PROJECT: 1851 Wildfire Rd, Estes Park CO
LAB CODE: B2214275
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE: 10/21/22
TOTAL SAMPLES ANALYZED, 50
# SAMPLES >1°/0 ASBESTOS:
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
euro ins
CE
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: 1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is
not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on
request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding
the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in
acceptable condition unless otherwise noted. This report may not be used by the client to claim
product endorsement by NVLAP or any other agency of the U.S. Government,
Information provided by customer includes customer sample ID and sample description.
ANALYST:
/f
Scott Minyard
TESTING
NVLAP LAB CODE 10176d-0
APPROVED BY:
Tianbao Bai, Ph.D., CH
Laboratory Director
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 10 of 10
eu o ins
cep
ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
Client: SilverKey Services, LLC
PO Box 2641
Loveland, CO 80539
Project: 1851 Wildfire Rd, Estes Park CO
Lab Code: B2214275
Date Received: 10-19-22
Date Analyzed: 10-21-22
Date Reported: 10-21-22
ASBESTOS BULK PLM, EPA 600 METHOD
HA18-42 Shingle
B2214275,42
HA19-43 Roofing Paper
R22142.75.43
HAI9-44 Roofing Paper
B2214275.44
HA2O-45 Vent Caulking
B2214275.45
HA20-46 Vent Caulking
B2214275.46
Heterogeneous
Black,Tan
Fibrous
Bound
50%
Fiberglass 40%
Tar
10% Gravel
Heterogeneous 60% Cellulose 40% Tar
Black
Fibrous
Bound
Heterogeneous 60% Cellulose 40% Tar
Black
Fibrous
Bound
Heterogeneous
Black
Non -fibrous
Bound
Heterogeneous
Black
Non -fibrous
Bound
HA21-47 Plaster
B2214275.47
HA21'-48 Plaster
B2214275.48
Heterogeneous
Tan,Gray
Non -fibrous
Tightly Bound
Heterogeneous
Tan,Gray
Non -fibrous
Tightly Bound
100% Caulk
100% Caulk
65% Silicates
35% Binder
<1 % Paint
65% Silicates
35% Binder
<1% Paint
None Detected
None Detected
None Detected'
None Detected
None Detected
None Dete
ed
None Detected
730 SE Maynard Road • Cary„ NC 27511 • 919.481.1413
Page 8 of 10
eu ons
CE
ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
Client: SilverKey Services, LLC
PO Box 2641
Loveland, CO 80539
Project: 1851 Wildfire Rd, Estes Park CO
Lab Code: B2214275
Date Received: 10-19-22
Date Analyzed: 10-21-22
Date Reported: 10-21-22
ASBESTOS BULK PLM, EPA 600 METHOD
HA13-30 Surface Material
B2214275 30
Heterogeneous
White
Non -fibrous
Bound
HA13-31 Surface Material Heterogeneous
B2214275.31 White
Non -fibrous
Bound
HA13-32 Surface Material
B2214275.32
HA14-33 Joint Compound
Layer 1
B2214275.33
Layer 2 Drywall
B2214275.33
HA14-34
Layer 1
02214275,34
Joint Compound
Heterogeneous
White
Non -fibrous
Bound
Heterogeneous
White
Non -fibrous
Bound
Heterogeneous
White,Tan
Fibrous
Bound
20% Cellulose
65%
30%
Binder
Foam
Paint
65% Binder
30% Foam
5% Paint
None Detected
None Detected
65% Binder
30% Foam
5% Paint
65% Binder
30%0 Cale Carb
5% Paint
80% Gypsum
None Detected
None Detected
None Detected
Heterogeneous
White
Non -fibrous
Bound
65% Binder
30%0 Cale Carb
5% Paint
Layer 2 Drywall Heterogeneous 20%
Cellulose 80% Gypsum _ _
B2214275.34
White,Tan
Fibrous
Bound
None Detected
None Detected
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Page 6 of 10
Q eu ins
ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
Client: SilverKey Services, LLC
PO Box 2641
Loveland, CO 80539
Project: 1851 Wildfire Rd, Estes Park CO
Lab Code: B2214275
Date Received: 10-19-22
Date Analyzed: 10-21-22
Date Reported: 10-21-22
ASBESTOS BULK PLM, EPA 600 METHOD
HAG-17
Layer 1
B2214275.17
Joint Compound
Layer 2 ti Drywall
B2214275.17
HA7-18 Flooring
B2214275.18
HA7-19 Flooring
B2214275.19
HA8-20
B2214275.20
tic
HA8-21 Mastic
B2214275.21
Heterogeneous
White
Non -fibrous
Bound
Heterogeneous
White,Tan
Fibrous
Bound
Heterogeneous
Tan,Brown
Non -fibrous
Bound
Heterogeneous
Tan,Brown
Non -fibrous
Bound
Homogeneous
Clear
Non -fibrous
Bound
Homogeneous
Clear
Non -fibrous
Bound
NON -A BEST
!PONENT,
ibrou
65%
30%
5%
Binder
Cale Carb
Paint
20% Cellulose 80% Gypsum
100% Vinyl
100V Vinyl
100% Mastic
None Detected
None Detected
None Detected
None Detected
None Detected
100% Mastic
None Detected
HA9-22 Flooring Heterogeneous 40% Cellulose 50% Vinyl
B2214275.22
White,Beige 10% Binder
Fibrous
Bound
None Detected
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 4 of 10
ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
Client: SilverKey Services, LLC
PO Box 2641
Loveland, CO 80539
Project: 1851 Wildfire Rd, Estes Park CO
Lab Code: B2214275
Date Received: 10-19-22
Date Analyzed: 10-21-22
nate Reported: 10-21-22
ASBESTOS BULK PLM, EPA 600 METHOD
HA3-6
B2214275.06
Attl^lbtatE
ON -AS
rous Non-Fibr
Heterogeneous
White
Non -fibrous
Bound
HA3-7 Surface Material Heterogeneous
B2214275.07 White
Non -fibrous
Bound
urtace Ma
rial
HA3-8 Surface Materiar Heterogeneous
B2214275.08 White, Blue
Non -fibrous
Bound
HA4-9 Joint Compound Heterogeneous
Layer 1 White
B2214275,09 Non -fibrous
Bound
-Layer 2 _Drywall', ® _
B2214275.09
HA4-10 Joint Compound
Layer 1
B2214275.10
Layer 2 Drywall
B2214275,10
65% Binder
30% Calc Carb
5% Paint
65% Binder
30% Calc Carb
5% Paint
65% Binder
30% Calc Carb
5% Paint
65%
30%
5%
Binder
Calc Carb
Paint
Heterogeneous 20% Cellulose 80% Gypsum
White,Tan
Fibrous
Bound
Heterogeneous
White
Non -fibrous
Bound
Heterogeneous
White,Tan
Fibrous
Bound
20% Cellulose
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
80% Gypsum None Detected
65%a
30%
5%
Binder
Calc Carb
Paint
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 2 of 10
cE1
PROJECT: 1851 Wildfire Rd, Estes Park CO
Asbestos Report Summary
By: POLARIZING LIGHT MIC OSCOPY
LAB CODE: B2214275
METHOD: EPA 6001 R93 / 116 and EPA 600 / M4-821020
HA11-26
HA1 1-27
HAl2-28
HAl2-29
HA 13-30
_..__. HA13-31
HA13-32
HA14-33
HA 14-34
B2214275.26
B2214275.27
White
White
B2214275.28 Blue
B2214275.29
B2214275.30
B2214275.31
B2214-275.32
Blue
ite
White
White
Caulking
Caulking
WoodWood Panel Mastic
Wood Panel Mastic
Surface Material'
Surface Material
urtace Material
Layer 1 B2214275.33 White Joint Compound
� ®_
Layer 2 B2214275.33mm White,Tan� Drywall
Layer 1 B2214275.34 White Joint Col-npound
Layer 2 B2214275.34 _ mm White,Tan� m Drywall
HA 15-35
HA1 5-36
HA16-37
HA 16-38
HA17-39
HA17-40
HA18-41
HA1 8-42
HA 19-43
HA 19-44
HA2O-45
H'A20-46
B2214275.35
B2214275.36
B2214275.37
B2214275.38
B2214275 39
Black
Black
Roofing Paper
Roofing Paper up
Brown Window Caulking
Brown Window Caulking
Pink,Tan Drywall
B2214275,40 White,Tan Drywall
B2214275.41 Black,Tan_ Shingle
B2214275.42 Black,Tan Shingle
B2214275.43 Black Roofing Paper
Black Roofing Paper
Black Vent Caulking
9
82214275.44
B2214275,45
B2214275.46
HA21-47
HA21-48
HA22-49
HA22-50
B2214275.47
B2214275.48
B2214275.49
Black Vent Caulking
Tan,Gray
Plaster
Tan,Gray Plaster
Gray
Mortar
B22142.75.50 Gray
Mortar
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
v None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
730 CE Maynard Road • Cary, NC 27511 • 919.481.1413
Page 2of2