HomeMy WebLinkAboutREPORT Asbestos Inspection 1851 Wildfire Rd 2022-10-18SilverK Services Asbestos Inspection and Sampling Report 1851 Wildfire Rd. Estes Park., CO 80517 Presented To: Westover Construction 1789 Wildfire Rd. Estes Park, CO 80517 Performed & Prepared By: Thomas Cartmell SilverKey Services P.O. Box 2641 Loveland, CO. 80539 Phone: 970-215-1874 ceartmell@silverkeyservice.corn Project Details: Project Number: B2214275 Conducted; October 18ih 2022 1 1 Page PROJECT OVERVIEW lA Introduction On October 18'h 2022, Thomas Cartmell with SilverKey Services conducted a limited asbestos inspection and collected asbestos hulk -samples of suspect asbestos -containing materials (ACM) within a portion of the residence located at 1851 Wildfire Rd. Estes Park, CO 80517. The purpose of the limited inspection was to identify and sample potentially hazardous friable and non -friable ACM that has either been affected by a recent full scrape and/or may be impacted by subsequent restoration activities. 2.0 Scope of Work The scope of the limited inspection and bulk -sampling was limited to specific areas of the residence defined by the contractor. The following areas include: the Southeast bedroom, Northeast bedroom, kitchen, bathroom, living room, upstairs loft, basement, roofing, garage, and the exterior rock. The suspect materials being tested include: Drywall, texture, joint compound, flooring material, caulking, roofing paper, and shingles. The remaining areas within the residence, garage or any outbuilding on the property were not included in the scope of the inspection. The limited asbestos inspection did not constitute a full building inspection and does not fulfill the asbestos inspection requirements for structures that are to he demolished. 3.0 Site Description Single Family Residence 4.0 Certifications The limited asbestos inspection and bulk -sampling was conducted by Thomas Cartmell with SilverKey Services. Thomas Cartmell is a Colorado Department of Public Health and Environment. (CDPHE) certified Building Inspector; having certification number 26919. 5.0 Inspection, Sampling & Analytical Procedures 5.1 Inspection Procedures The limited asbestos inspection was conducted by an Environmental Protection Agency (EPA) and CDPHE certified Building Inspector. The inspection procedures included identifying and sampling suspect ACM within the pre -defined areas, submitting samples to an accredited laboratory for analysis, classifying the materials and assessing their condition, and compiling a final report detailing the inspection and the analytical results of the bulk -samples. P age 6.2 Material Classifications Sampled materials are divided into one of the following three categories:. • Surfacing Material: sprayed or troweled onto structural building members • Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation • Miscellaneous Material: all other materials not classified in the above two categories 6.3 Material Conditions Sampled materials are placed into one of the three following categories of conditions: • Good: none to very little visible damage or deterioration • Damaged: the surface is crumbling, blistered, water -stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed, or one -quarter if the damage is localized • Significantly Damaged: the surface is crumbling, blistered, water -stained, gouged, marred or otherwise abraded over greater than one -tenth of the surface if the damage is evenly distributed, or one -quarter if the damage is localized. 6.4 Sample Quantities SilverKey Services collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this report are approximate and on -site verification of the exact quantity of each material is required. The following outlines the minimum sample quantities required per homogeneous area: • Surfacing Materials: up to 1,000 ft2 of material requires a minimum of three (3) samples; between 1,000 ft2 and 5,000 ft2 of material requires a minimum of five (5) samples; over 5,000 ft2 of material requires a minimum of seven (7) samples; one (1) sample of each patch • Thermal System Insulation (TSI): each homogeneous area requires a minimum of three (3) samples; at least one (1) sample must be collected from each patch; and collect enough samples sufficient to adequately assess the material and determine the asbestos content for TSI fittings such as pipe elbows or T's. • Miscellaneous Materials: collect enough samples sufficient to determine the asbestos Content 7. Overview of Finding Asbestos was not reported within some of one or more of the samples collected. Therefore, abatement of these materials will not be required. SilverKey Services collected a total of (50) asbestos bulk -samples of (22) homogeneous areas. Table 1 below describes the materials composing each homogeneous area as well as the locations of each bulk sample collected. Also listed is the classification, condition, friability and estimated quantity of material to be removed and/or disturbed, as well as the asbestos content within each bulk -sample. Please see Appendix B: Analytical Data for the layer break -down of each bulk -sample. 51fage HOMOGENEOUS SAMPLING AREA: HA4 MATERIAL DESCRIPTION: Joint compound/drywall COLOR: White PATTERN: NA QUANTITY: 50 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Bathroom Southwest corner wall, bathroom Southeast corner wall # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA4-009, HA4-010 RESULT: ND FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA: HA5 MATERIAL DESCRIPTION: Surfacing material COLOR: White PATTERN: Orange peel QUANTITY: 1,000 sq ft CONDITION: G MATERIAL CATEGORY: SM LOCATION: Southeast bedroom North wall, Northeast bedroom. West wall, kitchen North wall, living room South wall, upstairs loft South wall # OF SAMPLES TAKEN: 5 SAMPLE ID NUMBER(S): HA5-011, HA5-012, HAS-013, HAS-014, 1-1A5-01.5 RESULT: N D FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA: HA6 MATERIAL DESCRIPTION: Joint compound/drywall COLOR: White PATTERN: NA QUANTITY.: 1,000 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Upstairs loft Northwest corner wall, kitchen Southwest corner wall # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA6-016, 1-IA6-017 RESULT: ND FRIABILITY: Friable 7 I Page HOMOGENEOUS SAMPLING AREA: HA10 MATERIAL DESCRIPTION: Mastic COLOR: Yellow PATTERN: NA QUANTITY: 50 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Bathroom vinyl flooring # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA10-024, HA10-025 RESULT: ND FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA: HA11 MATERIAL DESCRIPTION: Caulking COLOR: White PATTERN: NA QUANTITY: 25 LF CONDITION: G MATERIAL CATEGORY: MM LOCATION: Kitchen counter, bathroom counter # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA11-026, HA11-027 RESULT: ND FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA: I-1A 12 MATERIAL DESCRIPTION: Mastic COLOR: Blue PATTERN: NA QUANTITY: 600 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Basement wood paneling # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HAl2-028, HAl2-029 RESULT: ND FRIABILITY.: Friable 9WPa e HOMOGENEOUS SAMPLING AREA: HA16 MATERIAL DESCRIPTION: Caulking COLOR: Brown PATTERN: NA. QUANTITY: NA CONDITION: G MATERIAL CATEGORY: MM LOCATION: Window # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA16-037, HA16-038 RESULT: ND FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA; HA17 MATERIAL DESCRIPTION: Drywall COLOR: Pink, tan PATTERN: NA QUANTITY: NA CONDITION: G MATERIAL CATEGORY: MM LOCATION: Garage ceiling ## OF SAMPLES TAKEN; 2 SAMPLE ID NUMBER(S): HA17-039, HA17-040 RESULT: ND FRIABILITY: Friable HOMOGENEOUS SAMPLING AREA: HA18 MATERIAL DESCRIPTION: Shingles COLOR: Black, tan PATTERN; NA QUANTITY: 1,000 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Garage # OF SAMPLES TAKEN: 2 SAMPLE ID NUMBER(S): HA18-041, HA18-042 RESULT: ND FRIABILITY. Friable 1 HOMOGENEOUS SAMPLING AREA: HA22 MATERIAL DESCRIPTION: Mortar COLOR: Gray PATTERN: NA QUANTITY: 500 sq ft CONDITION: G MATERIAL CATEGORY: MM LOCATION: Exterior rock # OF SAMPLES TAKEN: 2 SAMPLE ID NUMi ER(S): HA22-04-9, HA22-050 RESULT: ND FRIABILITY: Friable ND -Non -detect HA- Homogenous Area TR-Trace, <1% D-Damaged MM-Miscellaneous Material G-Good SM-Surfacing Material SD -Significantly Damage TSl-Thermal System Insulation It is the responsibility of the asbestos abatement company to give cr scope of work for all abatement. 8. Findings & Recommendations ACM was not identified within the following areas: the Southeast bedroom ceiling surfacing material, Northeast bedroom ceiling surfacing material, kitchen ceiling surfacing material, kitchen North corner ceiling joint compound/drywall, bathroom West corner ceiling joint compound/drywall, bathroom West wall surfacing material, bathroom South wall surfacing material, bathroom East wall surfacing material, bathroom Southwest corner wall joint compound/drywall, bathroom Southeast corner wall joint compound/drywall, Southeast bedroom North wall surfacing material, Northeast bedroom West wall surfacing material, kitchen North wall surfacing material, living room South wall surfacing material, upstairs loft South wally surfacing material, upstairs loft Northwest corner wall joint compound/drywall, kitchen Southwest corner wall joint compound/drywall, kitchen vinyl flooring or mastic, bathroom vinyl flooring or mastic, kitchen counter caulking, bathroom counter caulking, basement wood paneling or mastic, basement ceiling surfacing material, basement North ceiling corner joint compound/drywall, roofing shingles paper, window caulking, garage ceiling drywall, garage shingles, roofing shingles paper, garage roofing vent caulking, exterior plaster, or the exterior rock mortar that were within the scope of the limited inspection and bulk -sampling performed on October 18,1' 2022; therefore, professional abatement activities arc not required to remove or disturb the above -reference sampled materials. ACM was not impacted or disturbed. We do not consider this a spill; SilverKey Services recommends that when ACM is removed/abated, that only a licensed asbestos abatement contractor using personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA- filtered vacuuming, wet cleaning methods,respiratory protection, protective clothing, personnel decontamination, negative -air enclosures, air monitoring, etc.). For all spills, SilverKey Services recommends that all soft goods (carpet, pad, clothes, couches, etc.) and any ceiling and/or wall surfacing restoration activities be removed from the interior of the building as asbestos waste. SilverKey Services also advises that only hard surfaces (plastic, metal, wood, concrete, etc.) are allowed to be left in place before the final visual and final air clearance 13 I Page Microvacuum samples must be collected and analyzed in accordance with the procedures specified in the ASTM International Method D5755-09 (Reapproved April 2014), "Standard Test Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Surface Loading." Wipe samples must be collected and analyzed in accordance with the procedures specified in the ASTM International Method D6480-19 (January 2019), "Standard Test Method for Wipe Sampling of Surfaces, Indirect Preparation, and Analysis for Asbestos Structure Number Surface Loading by Transrission Electron Microscopy." • The General Abatement Contractor (GAG) selected to perform the cleanup of the spill must: Submit notification in accordance with subsection III.E. (Notifications) or subsection III.G. (Permits), whichever is applicable to the Division for approval. • Using certified Supervisors and certified Workers in accordance with section II. (Certification. Requirements), construct a containment in accordance with the following mandatory subsections, which must be followed in the exact sequence shown: Construct the decontamination unit in accordance with subsection Il1.K. (Decontamination Unit). Install critical barriers in accordance with subsection 111.1. (Critical Barrier installation) Comply with the requirements of subsection lll.l. (Air Cleaning and Negative Pressure Requirements) HEPA vacuum or steam clean all carpets, drapes, upholstery, and other non -clothing fabrics in the contaminated area, or discard these materials in accordance with subsection III.R. (Waste handling) Launder or discard all contaminated clothing in accordance with subsection. III.R. (Waste Handling). HEPA vacuum or wet wipe with clean area. ended water on a l hard surfaces in the contaminated Discard all waste in accordance with subsection III.R. (Waste Handling). Ensure items cleaned as part of the spill response are included in the clearance process. • All persons must comply with any other measures, provided in wriling by the Division, which are deemed necessary to protect public health. • Following completion of Sections 111.T.2_d.(i) through II1.T.2.e., the AMS must comply with air monitoring requirements as described in Section II LP. (Clearing Abatement Projects); air samples. must be collected aggressively as described in 40 C.P.R. Part 763, Appendix A to Subpart E (EPA 2010), except that the air stream of the leaf blower must not be directed at any friable ACM that remains in the area. 5 1 Page 10.0 Disclaimer 8, Limitations The activities outlined in this report were conducted in a manner consistent with a level of care and expertise exercised by members of the environmental consulting and industrial hygiene profession. All activities were performed in accordance with all applicable federal, state, and local regulations as well as generally accepted standards and professional practice. No warranty is either expressed. or implied. SilverKey Services assumes no responsibility or liability For error in public information utilized, statements from sources other than. SilverKey Services, or developments resulting from situations outside the scope of this project. The details provided within this report outline the inspection activities on the date(s) indicated and should not be relied upon to represent conditions at a later date, the limited number of bulk samples collected, and the laboratory results of those bulk -samples. The laboratory results contained in this report apply specifically to the materials in which bulk -samples were collected. The results do not include or apply to any other materials within the structure that were not sampled, but may contain asbestos; including materials that may be hidden or inaccessible. Additional inspection and bulk -sampling activities would be required to determine if any other materials contain asbestos. This report has been prepared on behalf of and exclusively for use by the Client, with specific application to their project as discussed in the scope of work. The results of any surfacing material indicated in this report also includes any associated overspray of that material, e.g., under carpet, above suspended ceilings, etc. The information contained in this report is intended as supplementary material for abatement design and is not to be used as the scope of work for abatement activities, bidding or billing purposes. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Thank you for your business. Sincerely, Thomas Cartmell State of Colorado Building Inspector Accreditation No: 26919 Exp. 6/21/2023 SilverKey Services Asbestos Consulting Firm Registration No: ACF-23285 17 I Page 19 I Page 21 V Page 23 I Page 25 1 Page e rorins ASB STOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for SilverKey Services, LLC CLIENT PROJECT: 1851 Wildfire Rd, Estes Park CO LAB CODE: B2214275 TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORT DATE: 10/21/22 TOTAL SAMPLES ANALYZED, 50 # SAMPLES >1°/0 ASBESTOS: 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 euro ins CE LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORTING LIMIT: <1% by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points REGULATORY LIMIT: 1% by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government, Information provided by customer includes customer sample ID and sample description. ANALYST: /f Scott Minyard TESTING NVLAP LAB CODE 10176d-0 APPROVED BY: Tianbao Bai, Ph.D., CH Laboratory Director 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 10 of 10 eu o ins cep ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: SilverKey Services, LLC PO Box 2641 Loveland, CO 80539 Project: 1851 Wildfire Rd, Estes Park CO Lab Code: B2214275 Date Received: 10-19-22 Date Analyzed: 10-21-22 Date Reported: 10-21-22 ASBESTOS BULK PLM, EPA 600 METHOD HA18-42 Shingle B2214275,42 HA19-43 Roofing Paper R22142.75.43 HAI9-44 Roofing Paper B2214275.44 HA2O-45 Vent Caulking B2214275.45 HA20-46 Vent Caulking B2214275.46 Heterogeneous Black,Tan Fibrous Bound 50% Fiberglass 40% Tar 10% Gravel Heterogeneous 60% Cellulose 40% Tar Black Fibrous Bound Heterogeneous 60% Cellulose 40% Tar Black Fibrous Bound Heterogeneous Black Non -fibrous Bound Heterogeneous Black Non -fibrous Bound HA21-47 Plaster B2214275.47 HA21'-48 Plaster B2214275.48 Heterogeneous Tan,Gray Non -fibrous Tightly Bound Heterogeneous Tan,Gray Non -fibrous Tightly Bound 100% Caulk 100% Caulk 65% Silicates 35% Binder <1 % Paint 65% Silicates 35% Binder <1% Paint None Detected None Detected None Detected' None Detected None Detected None Dete ed None Detected 730 SE Maynard Road • Cary„ NC 27511 • 919.481.1413 Page 8 of 10 eu ons CE ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: SilverKey Services, LLC PO Box 2641 Loveland, CO 80539 Project: 1851 Wildfire Rd, Estes Park CO Lab Code: B2214275 Date Received: 10-19-22 Date Analyzed: 10-21-22 Date Reported: 10-21-22 ASBESTOS BULK PLM, EPA 600 METHOD HA13-30 Surface Material B2214275 30 Heterogeneous White Non -fibrous Bound HA13-31 Surface Material Heterogeneous B2214275.31 White Non -fibrous Bound HA13-32 Surface Material B2214275.32 HA14-33 Joint Compound Layer 1 B2214275.33 Layer 2 Drywall B2214275.33 HA14-34 Layer 1 02214275,34 Joint Compound Heterogeneous White Non -fibrous Bound Heterogeneous White Non -fibrous Bound Heterogeneous White,Tan Fibrous Bound 20% Cellulose 65% 30% Binder Foam Paint 65% Binder 30% Foam 5% Paint None Detected None Detected 65% Binder 30% Foam 5% Paint 65% Binder 30%0 Cale Carb 5% Paint 80% Gypsum None Detected None Detected None Detected Heterogeneous White Non -fibrous Bound 65% Binder 30%0 Cale Carb 5% Paint Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum _ _ B2214275.34 White,Tan Fibrous Bound None Detected None Detected 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 6 of 10 Q eu ins ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: SilverKey Services, LLC PO Box 2641 Loveland, CO 80539 Project: 1851 Wildfire Rd, Estes Park CO Lab Code: B2214275 Date Received: 10-19-22 Date Analyzed: 10-21-22 Date Reported: 10-21-22 ASBESTOS BULK PLM, EPA 600 METHOD HAG-17 Layer 1 B2214275.17 Joint Compound Layer 2 ti Drywall B2214275.17 HA7-18 Flooring B2214275.18 HA7-19 Flooring B2214275.19 HA8-20 B2214275.20 tic HA8-21 Mastic B2214275.21 Heterogeneous White Non -fibrous Bound Heterogeneous White,Tan Fibrous Bound Heterogeneous Tan,Brown Non -fibrous Bound Heterogeneous Tan,Brown Non -fibrous Bound Homogeneous Clear Non -fibrous Bound Homogeneous Clear Non -fibrous Bound NON -A BEST !PONENT, ibrou 65% 30% 5% Binder Cale Carb Paint 20% Cellulose 80% Gypsum 100% Vinyl 100V Vinyl 100% Mastic None Detected None Detected None Detected None Detected None Detected 100% Mastic None Detected HA9-22 Flooring Heterogeneous 40% Cellulose 50% Vinyl B2214275.22 White,Beige 10% Binder Fibrous Bound None Detected 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 4 of 10 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: SilverKey Services, LLC PO Box 2641 Loveland, CO 80539 Project: 1851 Wildfire Rd, Estes Park CO Lab Code: B2214275 Date Received: 10-19-22 Date Analyzed: 10-21-22 nate Reported: 10-21-22 ASBESTOS BULK PLM, EPA 600 METHOD HA3-6 B2214275.06 Attl^lbtatE ON -AS rous Non-Fibr Heterogeneous White Non -fibrous Bound HA3-7 Surface Material Heterogeneous B2214275.07 White Non -fibrous Bound urtace Ma rial HA3-8 Surface Materiar Heterogeneous B2214275.08 White, Blue Non -fibrous Bound HA4-9 Joint Compound Heterogeneous Layer 1 White B2214275,09 Non -fibrous Bound -Layer 2 _Drywall', ® _ B2214275.09 HA4-10 Joint Compound Layer 1 B2214275.10 Layer 2 Drywall B2214275,10 65% Binder 30% Calc Carb 5% Paint 65% Binder 30% Calc Carb 5% Paint 65% Binder 30% Calc Carb 5% Paint 65% 30% 5% Binder Calc Carb Paint Heterogeneous 20% Cellulose 80% Gypsum White,Tan Fibrous Bound Heterogeneous White Non -fibrous Bound Heterogeneous White,Tan Fibrous Bound 20% Cellulose None Detected None Detected None Detected None Detected None Detected None Detected 80% Gypsum None Detected 65%a 30% 5% Binder Calc Carb Paint 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 2 of 10 cE1 PROJECT: 1851 Wildfire Rd, Estes Park CO Asbestos Report Summary By: POLARIZING LIGHT MIC OSCOPY LAB CODE: B2214275 METHOD: EPA 6001 R93 / 116 and EPA 600 / M4-821020 HA11-26 HA1 1-27 HAl2-28 HAl2-29 HA 13-30 _..__. HA13-31 HA13-32 HA14-33 HA 14-34 B2214275.26 B2214275.27 White White B2214275.28 Blue B2214275.29 B2214275.30 B2214275.31 B2214-275.32 Blue ite White White Caulking Caulking WoodWood Panel Mastic Wood Panel Mastic Surface Material' Surface Material urtace Material Layer 1 B2214275.33 White Joint Compound � ®_ Layer 2 B2214275.33mm White,Tan� Drywall Layer 1 B2214275.34 White Joint Col-npound Layer 2 B2214275.34 _ mm White,Tan� m Drywall HA 15-35 HA1 5-36 HA16-37 HA 16-38 HA17-39 HA17-40 HA18-41 HA1 8-42 HA 19-43 HA 19-44 HA2O-45 H'A20-46 B2214275.35 B2214275.36 B2214275.37 B2214275.38 B2214275 39 Black Black Roofing Paper Roofing Paper up Brown Window Caulking Brown Window Caulking Pink,Tan Drywall B2214275,40 White,Tan Drywall B2214275.41 Black,Tan_ Shingle B2214275.42 Black,Tan Shingle B2214275.43 Black Roofing Paper Black Roofing Paper Black Vent Caulking 9 82214275.44 B2214275,45 B2214275.46 HA21-47 HA21-48 HA22-49 HA22-50 B2214275.47 B2214275.48 B2214275.49 Black Vent Caulking Tan,Gray Plaster Tan,Gray Plaster Gray Mortar B22142.75.50 Gray Mortar None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected v None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected 730 CE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 2of2