Loading...
HomeMy WebLinkAboutPLANS Modification 420 Steamer Dr 101 2022-05-12R 1' 4' 5'-7" LOBBY FEC R=15'-1 1/2" +/- MATCH (E) FLR TRANSITION HINGEAPPROACH, PUSH SIDE MANEUVERING CLEARANCE @ MANUALSWING DOORS PER ICC A117.1-2009 48" WITH CLOSERAND LATCH; 42" W/OUT 5'-7" VERIFY 9' - 1 1 1 / 2 " V E R I F Y 2" 6' - 1 0 " 8" 2' - 1 1 / 2 " 2" (E)XISTING TO REMAIN RMV (E) GLASS AND FRAME (E) TO REMAIN 3' - 4 " 10 " 4"3'-4"4" 2"4'2"1'-1"2" 4" R IC E R R R R FEC FEC FE C FEC 1 1/8" = 1'-0" PROPOSED PLAN 2 1/4" = 1'-0" PROPOSED ELEVATION -(N)EW 4'-0"x7'0"ALUM ENTRANCE DOOR W/ SIDELIGHTS. MATCH (E)XISTING FRAMEAND GLASS COLORS/MATERIALS/SPECIFICATIONS -LCN HEAVY DUTY DOOR OPERATOR W/ RFACTUATORS EASIDE -PULL@ EXTERIOR, PUSH BAR @ INTERIOR; FINISH TO MATCH (E) HARDWARE -LOCKSET KEYED TO MATCH (E) SYSTEM (N) PARTIALHEIGHT WALL, GWB EASIDE ON 3 5/8" MTLSTUDS 60"ABOVE FINISHED FLOOR (VERIFY EXACT HEIGHT W/ OWNER) T = TEMPERED GLAZING, 1" INSUL. TYPICAL (N) THRESHOLD, PATCH (E) FLOORING TO MATCH WHERE DISTURBEDAT (N) OPENING THIN PROFILEADARFACTUATOR THIS LOCATION @ EXTERIOR & INTERIOR CONCEALED DOOR OPERATOR T T TT T VICINITY MAP CODE SUMMARY APPLICABLE CODES: 2015 INTERNATIONALBUILDING CODE 2015 INTERNATIONALENERGY CONSERVATION CODE 2015 INTERNATIONALMECHANICALCODE 2015 INTERNATIONALPLUMBING CODE 2015 NATIONALELECTRICALCODE 2015 INTERNATIONALFIRE CODE 2015 INTERNATIONALFUELGAS CODE 2010ADASTANDARDS FORACCESSIBLE DESIGN 2009ANSI ICCA117.1 GOVERNINGAUTHORITY: TOWN OF ESTES PARK, COUNTY OF LARIMER, STATE OF COLORADO PROJECT DESCRIPTION: In general the Project consists of installing a new door in the existing storefront system for Estes Park Health at 420 Steamer Drive (Alarado Business Park). This is not a required exit. The Project is protected throughout by a NFPA 13 sprinkler system. CONSTRUCTION TYPE:V-B OCC CLASSIFICATION(S):B | BUSINESS AUTOMATIC SPRINKLER SYSTEM:COMPLETE per Sec 903.3.1.1 NFPA13 sprinkler systems. FIREALARM & DETECTION:NO CHANGES TO EXISTING SYSTEMS EXIT SIGN:ADD EXIT SIGNAT INTERIOR, MATCH (E) SIGN TYPE. NOTE, THIS IS NOTAREQUIRED EXIT ENLARGED AREA 42 0 S t e a m e r D r i v e , S u i t e 1 0 1 Es t e s P a r k C O - BAS1S.com 970.586.9140 16 9 2 B i g T h o m p s o n A v e , S t e 1 0 0 Es t e s P a r k , C o l o r a d o 8 0 5 1 7 Sheet Title:Sheet Title: PT Entry Door T e n a n t M o d i f i c a t i o n s : Es t e s P a r k H e a l t h A1 Sheet No: PERMIT & CONSTRUCTION Date: Issue: 4/8/22 Architecture, P.C. ©BASIS OLORRADO 04/08/2022 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 05/12/2022 THIS STRUCTURE MUST COMPLY WITH THE REQUIREMENTS OF THE 2020 NATIONAL ELECTRICAL CODE