HomeMy WebLinkAboutLETTER Beam Size Remodel 359 Big Boulder Dr 2022-09-09LAND SURVEYS SUBDIVISIONS DEVELOPMENT PLANNING IMPROVEMENT PLATS STRUCTURAL ENGINEERING SANITARY ENGINEERING MUNICIPAL ENGINEERING DATE: F ROM: R E: VAN HORN ENGINEERING AND S RVEY NG September 9, 2.022 Building Department .E, .Roberts, P„E, Beani Size to Replace Wall Revised to Include Door Header n Basemen 359 Big Boulder Drive Estes Park, C() 80517 2015 IRE Ground Snow Load= 67..1 psf (at 7 7 0' elev. V 175 mph, Exp. C Seismic .Design Category 13 This project involves removal oldie triain level wall between the kitchen and living room. -Ibis wall does not support roorload as the rafters span from outer wall to outer wall, This wall does support the ceiling joists and a replacement beam will be necessary with the following specifications: • Bearttsize, 6x14 Douglas Fir #1 or better • Beam span, 23.-4" • South end support: (3) 2x4 jack studs bearing over existing foundation w install solid blocking through floor depth as necessary • North end sup_porl: (3) 2x4 jack studs bearing over basernent trailed wall., install solid blocking through floor depth as necessar1nstall header in basement wall doorway: (2) 2x1l.0 or (2) 13/4"x5 LVLs and (1 ) 2x4 jack stud each end of header within basement frarned wall • All framing lumber shall be Hern Fir #2 or 'better, S Ft C ere ly, 6'6 CA:, Frank Roberts, P..E. 1043 Fisti Creek Road • Estes Park, Colorado 80517 • 970-586-9388 • E-mail: info4vanhornengineermg.co'