PLANS 23-116 800 Big Thompson Ave, Discovery Lodge, remodel 2023-03-27
DISCOVERY LODGE REMODEL - PHASE I 800 Big Thompson Ave., Estes Park, CO 80517 ©2023 Interstice Architectural Studio, LLC Permit Information D. FIRE PROTECTION SYSTEMS 1. Automatic Fire Sprinkler System NFPA 13R System Required 2. Standpipe System Not Required 3. Portable Fire Extinguishers Required / Existing - See Sheet A3 4. Fire Alarm, Detection and Monitoring Required E. EGRESS 1. Emergency Escape and Rescue a. Sleeping rooms require a means of egress directly to the exterior Existing doors meet this requirement 2. Exit signs Not Required within dwelling units 3. Emergency Lighting a. Within dwelling unit Not Required b. Exterior Stairways Required 4. Exit Access Travel Distance (1017) a. Group R Sprinklered 250' allowed b. Exterior Balcony Increase Up to 100' additional c. All lower level rooms exit nearly directly to public way. Upper level rooms exit via balconies and exterior stairs. Travel distance in Building 500 from unit doors across balconies and descending stairs is about 60' maximum. For building 400 (which requires access to building 500 south stair), the distance is about 90'. All units in both buildings (except 4 at the east end of building 400) have choice of exit direction/stairway. The distance between building 400 and building 500 stairways is about 135' along the balcony. F. EXISTING BUILDING CODE 1. Classification “Alternation Level 3” 2. Work Area Entire Building 500 3. Prescriptive Requirements - Accessibility (IEBC Section 306) 4. Alteration Level 1 Requirements (IEBC Chapter 7) also apply to Level 3 a. No significant requirements or exceptions 5. Alteration Level 2 Requirements (IEBC Chapter 8) also apply to Level 3 a. Shafts Existing wall heater shafts to be removed and fireblocked a. Sprinkler not required for Alteration Level 2 b. Fire Alarm required 6. Alteration Level 3 Requirements (IEBC Chapter 9) a. Sprinkler required b. Accessibility Required G. ACCESSIBILITY 1. Required level of accessibility - "Accessible" (not Type A nor Type B) 2. Accessible Parking (Table 1106.2) a. About 60 existing parking spaces b. 3 accessible parking required c. 2 new accessible parking spaces provided with this project 3. Dwelling & Sleeping Units (Table 1107.6.1.1) a. About 48 existing units b. 2 accessible units required - roll-in showers not required c. 2 new accessible units provided by this project - roll-in shower not required, but provided to achieve future complete site compliance 4. Accessible Features required a. Accessible Route from Parking to Entrance b. Accessible Entrance c. Accessible Route from Entrance to Primary Functions d. Signs – No new signs are required within the unit e. Loading Zone – N/A H. ENERGY CONSERVATION 1. See Sheet A7 for new and existing thermal envelope insulation values Color Legend In these drawings colors represent... Demolition New Construction Items that have no color represent existing conditions to be maintained. Furniture and Appliances by Owner - Not In Contract Electronic Documents Documents and Resources are available on the project web site… http://www.intersticearch.com/discovery/ Vicinity Map Estes Park, Colorado Not to Scale north Graphics Legend Room Name100 100.1 A X#.# # XX.X XXX'-XX" Elevation 12 6 X'-X"XX'-X" X AXX X AXX X AXX X XXX AXX A 1 X T @ 11” = X’-XX” X R @ 7” = X’-XX”up XXXXX Slope Dn AdditionExisting ¼” 1 GRID LINES - typically indicate centerline or exterior edge of structural elements Drawing # Sheet # SECTION AND DETAIL REFERENCES INTERIOR ELEVATION REFERENCES ROOM NAME & NUMBER Refer to Room Finishes Schedule for finishes DOOR NUMBER TAG Refer to Door Schedule WINDOW LETTER TAG Refer to Window Schedule ROOM FINISH TAG Refer to Room Finishes Material List and/or Specifications EQUIPMENT TAG - Refer to Equipment or Accessories Schedules WORK NOTE TAG - Refer to Work List Keynotes DEMOLITION TAG - Refer to Demolition Keynotes # ELEVATION MARKERS - Relative to Elevation 100'-0" which is typically the Main Level Finish Floor elevation SLOPE INDICATORS - For Elevations/Sections and Plans respectively STAIRWAY RUN - indicates up/down direction, number and dimensions of treads and risers, and overall dimensions CHANGE IN CONDITION WELDED JOINT - Refer to the Manual of Steel Construction for interpretation of standard symbols and notes REVISION CLOUD AND NUMBER - Refer to revision dates listed in the title block below the sheet title ARCHITECTURAL A1 Title Sheet and Permit Information A2 Site Plan A3 Demolition Plans A4 Floor Plans A5 Enlarged Unit Plans A6 Bathroom Interior Elevations A7 Thermal Envelope & Openings STRUCTURAL S1 Structural Plan Sheet IndexProject Narrative Discovery Lodge is a collection of six motel building construction circa 1950s. The proposed remodel of Building 500 is the first in a series of project to improve the property. Building 500 consists of 6 lower level and 6 upper level dwelling units. The rooms are to be extensively remodeled including new exterior wall insulation, new interior wall sheathing, new doors, new bathroom fixtures and new finishes. All electrical devices have been upgraded - no change to service. This project is classified as a Level-3 Alteration by the IEBC. The most significant code requirement of this remodel project is the addition for an NFPA 13R fire sprinkler system in Building 500 which will be extended in the future to serve buildings 400 and 600 as well. In connection with the sprinkler system, a new fire hydrant is to be installed on the site. See Sheet A2 for general arrangement. Civil drawings are to be submitted separately for site work in connection with this project. The existing domestic water service to the building is to be maintained - domestic water will not attach to the fire sprinkler system at this time. The existing motel buildings do not provide adequate handicap accessibility. This project adds two fully accessible dwelling units. One including a roll-in showers. With these units (and associated new parking), this building is in compliance. However, future remodeling of Building 400 will require a third accessible unit for complete site compliance. APPLICABLE CODES 2015 International Building Code 2015 International Mechanical Code 2018 International Fire Code 2015 International Plumbing Code 2015 International Existing Building Code 2020 National Electric Code 2009 ICC/ANSI A117.1 Accessible and Useable Buildings and Facilities A. OCCUPANCY CLASSIFICATION 1. Occupancy Group Group R1 - Motel - Transient 2. Building Areas, Uses and Occupant Load Occupant Occupant Use Area Load Factor Load a. Lower Level (6) Accom Units 2338 sf 4 per unit 24 b. Upper Level (6) Accom Units 2341 sf 4 per unit 26 i. West Decks 322 sf ii. East Deck (to mid-pt btwn bldgs) 540 sf . c. Total Enclosed Area & Occupant Load 4679 sf 50 3. Special Requirements based on Occupancy a. Groups R (Section 420) i. Separation Walls (420.2 and 708) 1) Ratings a) Between Units 30-minutes b) Corridor No interior corridors* * No fire ratings required this project. However when building 400 is remodeled in future, upper level east rooms will require fire-rated north walls because there is no choice in exit direction (or stair will have to be relocated) 2) Openings (708.6 and Table 716.5) N/A this project** ** I the future remodel of building 400, (4) upper level east end doors will require rating ii. Horizontal Separation (420.3 and 711) 1) Rating a) Floor Assembly (711.2.4.3) 30-minutes b) Supporting Structure Non-rated - 711.2.3 excep 2 iii. Automatic Sprinkler System (420.5) NFPA 13R required iv. Fire and Smoke Alarms (420.6) Required B. CONSTRUCTION TYPE 1. Construction Type Type V-B 2. Assembly Requirements (IBC Tables 601 & 602) a. Primary Structural Frame Non-rated b. Exterior Bearing Walls (all >10') Non-rated c. Interior Bearing Walls See item A,3,a,i above d. Exterior Nonbearing Walls (all > 10') Non-rated e. Interior Partitions Non-rated f. Floor Construction See item A,3,b,ii above g. Roof Construction Non-rated 3. Interior Finishes (Chapter 8) a. All spaces this project i. Classification C ii. Max Flame Spread 200 iii. Max Smoke Development 450 C. ALLOWABLE HEIGHT AND FLOOR AREA 1. Allowable Height (Table 504.3) 60' > actual 25'± 2. Allowable Number of Stories (Table 504.4) 3 > actual 2 3. Allowable Floor Area (Table 506.2) 21,000 sf > 2341 sf per story a. Frontage Increase Not Taken Re v i s i o n 2 - 4 / 1 4 / 2 3 General Notes 1. Do not scale drawings for dimensions. Dimensions are typically to face of masonry or concrete and face of framing member, unless otherwise noted. 2. Clean-up of rubbish and debris resulting from work shall be collected regularly from project site and legally disposed of. 3. All weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and exterior openings shall be flashed in such a manner as to make them weatherproof. 4. Contractors are responsible for all materials and quantities shown in these drawings graphically as well as those called for by note. 5. The Contractor shall obtain all necessary permits to complete the work and shall comply with all local, state, and federal regulations. 6. All materials and construction shall be completed in accordance with the requirements of Town of Estes Park and the 2015 IBC. 7.Provide shoring, temporary bracing, barricades and other measures as necessary to ensure a safe building construction site. Establish a protected access route to the main house -- coordinate with Owner. 8.Contractor to verify existing conditions and review discrepancies or inconsistencies of site and drawings with Architect prior to construction. 9. Interior finishes must conform to the governing code for classification indicated to the right in "Code Information" Item B,3. 10. Provide accessibility complying with the Americans With Disabilities Act "ADA", ICC/ANSI A117.1-2009, International Building Code Chapter 11, and all local accessibility codes. 11. Field verify all rough openings and wall widths prior to ordering or fabrication of materials. 12. Subcontractors shall submit shop drawings for review and approval to the Fire Department for the fire sprinkler and fire alarm systems. 13. Maintain other building egress and access throughout the course of this project. No materials shall be stored in areas of egress. 14. Contractor shall take care during demolition to protect all items and materials to remain. Repair all damage caused by demolition to any areas of the property to its bid-time condition. Protect adjacent areas from damage, dirt, dust and fumes. 15. Provide blocking in all walls as required for door stops, fixtures, accessories, cabinetry and shelving (including shelving by Owner) - verify locations with Architect prior to drywall. Blocking may be either fire retardant treated 2x8 Douglas Fir lumber or 8" wide 24 ga galvanized steel strapping may be used per GC's option. 16. Asbestos mitigation has been previously completed for Building 500. Any suspicious materials discovered by the Contractor during demolition shall be immediately identified to the Architect and Owner. Bids shall not include cost or allowance for time delays associated with materials abatement. 17. Coordinate shutoff of power and other utilities with the Owner. Project Site 800 Big Thompson Ave 34 Big Th o m p s o n A v e 34 36 36 7 34 36 Elkhorn Av e Lake Estes 9-Hole Golf Course 4/14/23 Sheet NumberA1 Joseph E Calvin Date Sheet Title Title Sheet and Permit Information March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 04/18/2023 ©2023 Interstice Architectural Studio, LLC 501 502 503 504 505 506 Utility Room 410 Utility 409 408 407 406 405 404 403 402 401 601 603 602 604 605 Work Area See other sheets Building 500 Building 400 Building 600 Pond Island New accessible parking - See Sheet A4 Verify max 2% slope Architectural Site Plan Scale: 1" = 40'-0"plan tru e 0 20 40 60 80 Building 100 Building 200 Building 300 Big Thompson Ave – US Highway 34 Existing Driveways and Parking Ex i s t G r a d e Sl o p e D n Exi s t G r a d e Slo p e D n Exis t D r i v e Slop e D n Exist D r i v e Slope D n Exi s t D r i v e Slo p e D n Lake Estes 9-Hole Golf Course Residential Town Parking Lot Exis t D r i v e Slo p e D n Parking Parking Ex i s t G r a d e Slo p e D n 23 ' - 6 " ± Remove existing tree General Notes 1.This Site Plan is schematic in nature and provide in relation to the Architectural Drawings for purposes of a Building Permit only. A Civil Engineer shall be retained to provide more detailed and accurate plans for installation of site utilities under separate permiting. 2. The Contractor shall be responsible for the locations and protection of all existing utilities shown on these plans, all existing utilities not shown, and all proposed utilities. The existing utilities shown have been plotted from available information. Contractor shall contact representatives from the respective utility companies to have all of their utilities and facilities located prior to construction. 3. Contractor shall protect all adjacent improvements from damage and erosion. All disturbed areas shall be restored to a minimum of their original condition. 4. All water taps to public mains shall be installed by Contractor & inspected by the appropriate public agency. Water pipe shall be bedded and installed in accordance with Town standard specifications. 5. Asphalt paving shown shall be 3" asphaltic concrete complying with Colorado Department of Transportation Grade S or SX specification over 4" sand and 4" gravel aggregate base course comply with CDOT Class 5 or Class 6 specification requirements. Depressions shall not exceed 1⁄4" in 10'-0". 6. All areas disturbed due to grading & other construction activities shall be reseeded with native grasses. 7. Refer to Sheet A4 for more detailed requirements of accessible parking. Contractor shall verify maximum 2% slope in are of new accessible parking and regrade and repave as needed to establish this maximum slope. 20'-0" 86 ' - 0 " ± New fire lane See General Note #5 for paving reqs. E x i s t D r i v e S l o p e D n 50'-0"± Opposite parking may have to be modified or deleted to accommodate navigation to new accessible parking. Existing parking count exceeds EPDC requirements Propose approx fire hydrant location New 8" water line from main to hydrant New 4" water line to building New FDC See Sheet A5 Approx location of existing pond fill pipe - attach new floor drain to this line near building (See Sheet A5) Maintain exist covered breezeway 4/14/23 Sheet NumberA2 Joseph E Calvin Date Sheet Title Architectural Site Plan March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM Lower Level Demolition Scale: 1/8" = 1'-0"plan tru e 0 2 4 8 12 16Upper Level Demolition Scale: 1/8" = 1'-0"plan tru e 0 2 4 8 12 16 Accessible 501 Accessible 502 Typical Room 505 Unique Room 506 Typical Room 504 Typical Room 503 Typical Room 507 Typical Room 508 Typical Room 511 Unique Room 512 Typical Room 510 Typical Room 509 Remove existing door Remove wall adjacent ti door for new wider door Remove wall adjacent to door for new wider door Remove existing door Remove bathroom wall & door Remove bathroom wall & door Remove existing damaged deck post See Sheet A4 for new support Remove existing shaft - fireblock at ceiling and floor Remove existing shaft - fireblock at ceiling and floor Remove existing shaft - fireblock at ceiling and floor Remove existing shaft - fireblock at ceiling and floor Remove existing shaft - fireblock at ceiling and floor Remove existing shaft - fireblock at ceiling Remove existing shaft - fireblock at ceiling Remove existing shaft - fireblock at ceiling Remove existing shaft - fireblock at ceiling Remove existing shaft - fireblock at ceiling Remove existing shaft - fireblock at ceiling Remove all existing plumbing fixtures Remove all existing plumbing fixtures Remove all existing plumbing fixtures Remove all existing plumbing fixtures Remove all existing plumbing fixtures Remove all existing plumbing fixtures Utility Color Legend In these drawings, colors represent... Demolition New Construction Items that have no color represent existing conditions to be maintained. Furniture and Appliances by Owner - Not In Contract Remove existing shaft - fireblock at ceiling & floor Remove existing damaged deck post See Sheet A4 for new support 6'-4"6½"± Maintain existing fire extinguishers Maintain existing fire extinguishers Create 6'-4"W x 6'-10"T opening for new hollow metal double door and frame - install double 1¾"x9¼" LVL (3.0E) header with (2) jack and (1) king stud at both ends Trench for attaching new floor drain to existing pond fill line - see Sheet A2 Sawcut slab for new floor drain location 1' - 6 " mi n c l r Existing electrical panels and photovoltaic equipment Maintain existing stairway Completely remove existing tree, stump and roots in preparation for new road base - Take care to not disturb pond inlet line in proximity Maintain existing stairway Verify maximum 2% slope at proposed accessible parking spaces - refine grading and repave as needed - consult Architect as needed Demolition Notes 1. Provide temporary structural support for existing roof and floor structure where existing structural elements are to be demolished or modified. 2. Provide temporary building and site barricades where and when necessary. 3. Provide temporary enclosure for security and weather resistance. 4. Asbestos abatement procedure shall be fully completed and signed off before any work may proceed by GC. 5. Coordinate with Plumbing, Mechanical, and Electrical Contractors for additional demolition requirements. 6. The Contractor shall be responsible for legally disposing of all removed items and materials not to be reused or returned to the Owner. 7. Contractor shall protect all adjacent improvements/properties from damage and erosion. Any disturbed areas shall be restored to a minimum of their original condition per the erosion and sedimentary control plan. 8. Conditions depicted on these drawings have been compiled from available information and must be verified with on-site conditions. Notify Architect of any discrepancies between these drawings and the actual conditions. Beginning of work by Contractors indicates acceptance of all readily visible existing conditions. 9. Coordinate all utility shut-off with Owner. Maintain access to non-work areas. 10. Contractor shall clean-up work premises each day and thoroughly clean at completion of work. 4/14/23 Sheet NumberA3 Joseph E Calvin Date Sheet Title Demolition Plans March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM Lower Level Floor Plan Scale: 1/8" = 1'-0"plan tru e 0 2 4 8 12 16Upper Level Floor Plan Scale: 1/8" = 1'-0"plan tru e 0 2 4 8 12 16 Accessible 501 Accessible 502 Typical Room 505 Unique Room 506 Typical Room 504 Typical Room 503 Typical Room 507 Typical Room 508 Typical Room 511 Unique Room 512 Typical Room 510 Typical Room 509 12 ' - 0 " 12 ' - 0 " 12 ' - 0 " ± New deck post with accessible parking sign - per detail 1/A7 New accessible parking space New accessible parking space Existing parking spaces Reinstall existing parking blocks Existing striping New striping 8 ' - 0 " 8 ' - 0 " 8 ' - 0 " New deck post with accessible parking sign - per detail 1/A7 Utility 2 A5 1 A5 Color Legend In these drawings, colors represent... Demolition New Construction Items that have no color represent existing conditions to be maintained. Furniture and Appliances by Owner - Not In Contract New deck post re: Structural - typ Sprinkler Entry Fire Dpt ConnectionSprinkler riser up to ceiling soffit 45° angled wall - 2x4 - do not insulate 2x4 flat-framed soffit above for sprinkler trunk 2x4 flat-framed soffit above for sprinkler trunk 2x4 flat-framed soffit above for sprinkler trunk 2x4 flat-framed soffit above for sprinkler trunk - recommend over full bathroom of Room 506 Existing domestic water entry Floor Plan Notes 1. These notes shall also apply to Sheet A5. 2. All work shall comply with governing codes for construction and universal accessibility including the 2015 IBC, 2009 ICC/ANSI A117.1 Accessibility Guidelines, and the Americans with Disabilities Act (ADA). 3. Do not scale drawings for dimensions. Dimensions are typically to face of masonry or concrete and face of framing member, unless otherwise noted. 4. Contractors are responsible for all materials and quantities shown in these drawings graphically as well as those called for by note. 5. Interior Finishes must conform to IBC Chapter 8 requirements for minimum "Class C" having maximum flame spread of 200 and maximum smoke development of 450. 6. All interior walls to be framed to structure above except where otherwise noted. 7. Field verify all rough openings and wall widths prior to fabrication and/or ordering of materials. 8. Contractor to run a continuous bead of sealant around all doors, windows, and other openings or joints. Leave adjacent surfaces clean and provide backer rod where needed. 9. Provide min 2x8 blocking in framed walls for countertops, cabinetry, fixtures, shelving brackets, accessories, and door stops. Alternately 8" galvanized steel 24 ga plates and/or strapping may be used. 10. Provide sound batt insulation at all unit demising walls, in-unit bathroom walls, - typical. Refer to Sheet A7 for thermal insulation at exterior walls and roof. 2 A7 Refer to section for typical new and existing thermal insulation 2 A7 Refer to section for typical new and existing thermal insulation 1'-6"min Edge of new Fire Lane See Sheet A2 2x4 flat-framed soffit above for sprinkler trunk 1 1 April 7, 2023 4/14/23 Sheet NumberA4 Joseph E Calvin Date Sheet Title Floor Plans March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM 12Accessible Units Scale: 1/4" = 1'-0"plan tru e 0 1 2 4 6 8 Typical Units Scale: 1/4" = 1'-0"plan tru e 0 1 2 4 6 8 Accessible 501 Accessible 502 Typical Room 504 Typical Room 503 New furniture and appliances by Owner New furniture and appliances by Owner Existing sliding glass door Existing sliding glass door 2 1 1 opp 2 2 opp New 3'-0" door in expanded opening Accessible parking sign on new post - re: dtl 1/A7 Van Accessible parking sign on new post - re: dtl 1/A7 2'-3½" 1' - 7 ½" 2' - 4 " 1' - 7 ½" 2'-3½" 3' - 0 " m i n New furniture and appliances by Owner New furniture and appliances by Owner New tub/shower with tile surround New toilet and accessories New lavatory mounted on furniture to be selected by Owner New mirror - selected by Owner New rod & shelf at 5'-0" aff New 2x4 wall construction Coordinate location of all closet framing with Electrical Contractor regarding possible clearance conflicts - Notify Architect of conflicts New 2x4 wall construction Coordinate location of all closet framing with Electrical Contractor regarding possible clearance conflicts - Notify Architect of conflicts New rod & shelf at 5'-0" aff 3 4 1'-9" 3½" 3' - 9 " Rod & shelf at 4'-0" aff Rod & shelf at 4'-0" aff 3' - 6 " 1' - 8 " 2'-3½" 3'-2"2'-3" 2'-3"3'-2"New 3'-0" door in expanded opening New roll-in shower unit with fold-down seat 5'-0" x 4'-8" clearance required for toilet 2'-6" x 5'-0" clearance required for shower - lavatory is permitted to be within New 36" door - not self closing 2'-6" x 4'-4" clearance required at lavatory New accessible height, elongated bowl toilet (3) new grab bars - see elevations - install blocking within existing walls 1 New 2x4 insulated wall - install ⅝" DensglassL on Electric baseboard heater - 110V 600W - 2'-0" long Fire Department Connection - re: Sprinkler Drawings Water entry, valves, reduced pressure backflow preventer, and sprinkler risers - re: Sprinkler Drawings Install 6" floor drain - connect to existing pond file line - See Sheet A2 3 3 opp (2) jack and (1) king stud each end of new opening 4 New insulated hollow metal double door and frame Existing electrical panels and photovoltaic equipment Fire Dpt key box - re: Sheet A6, Door Elevation #4 3'-0" x 4'-0" door push-side clearance 4'-6" x 5'-0" door pull-side clearance 56 3½" 7 Reinstall existing bathtub with grab bars and transfer seat - adjust controls and shower head location - See 3/A6 Refer to sheet A6 for all interior elevations 2x4 flat-framed soffit above for sprinkler trunk See detail 3/A5 above New 2x4 wall construction - Coordinate location of all closet framing with Electrical Contractor regarding possible clearance conflicts - Notify Architect of conflicts Maintain fire extinguishers 1 3 Room 501 Sprinkler Soffit Scale: 1/4" = 1'-0"no r t h 0 1 2 4 6 8 Sprinkler riser closet Sprinkler line to extend west across ceiling of 501 and then up into floor framing to run north - firestop at all wall and ceiling penetrations Existing floor-ceiling framing 2x4 nailer against existing south wall 2x4 installed against ceiling - align with closet wall 2x4 blocking at min 24" oc - more than one layer may be required to get below sprinkler line 2x6 cont to providing nailing for flat framing 2x4 flat framing at 16"oc 2x4 edge member - wrap bottom and north surface in ⅝" gypsum board with corner bead - finish to match ceiling At Owner's option, LED can lights may be installed in soffit Sprinkler line to Upper Level Approx soffit height above floor Accessible Room 501 1 1 1 April 7, 2023 2'-6" x 5'-0" clearance required for tub - lavatory is permitted to be within 1 1 NOTE - A similar flat framed soffit is to be installed at the upper level dwelling units along the east wall of the building - estimated ceiling height below the soffit is 7'-6". 2 2 April 14, 2023 4/14/23 Sheet NumberA5 Joseph E Calvin Date Sheet Title Enlarged Unit Plans March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM 3" Door Wall1Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0"Lavatory Wall3Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0"Shower Wall4Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"Toilet Side2Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0" 3'-0"6" 2'-0"1'-0" 1'-6" 2' - 1 1 " 2' - 1 1 " 3'-6"1'-0" 3'-4" 1' - 6 " 3' - 4 " 3'-9½" to centerline of sink/mirror 2' - 1 0 " 6"8" 9" 1' - 6 " 3' - 4 " Bobrick B-5806 grab bars GFI outlet Mirror 24x36 ADA labeled wall- hung lavatory without backsplash and ADA lever- style faucet Protective pipe padding Bobrick B-5806 grab bars Ceramic wall tile up to 6'-3"aff with bull-nose cap & epoxy grout 2'-0" min 2' - 0 " m a x 1' - 5 " ADA labeled toilet Occupancy Sensor 1' - 7 " m a x Schluter DILEX-AHKA typ Epoxy painted drywall above tile (or alternately run tile full ht) Install tile-backer drywall behind wall tile locations Install solid blocking in wall at all grab bar locations 2'-6" Door Wall7Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0"Lavatory Wall5Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0"Shower Wall6Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0" Roll-over vinyl threshold ADA labeled fold-down shower seat (rectangular, not L-shape) 1'-3" 10 " 3' - 2 " 1' - 6 " 11"1'-4" 1'-6"1'-6" 3'-6"3" 1' - 0 " 1' - 6 " Locates shower controls within this rectagle Recommended location for soap/ bottle shelf 2' - 1 1 " Hosed shower head on height- adjustable rod Shower curtain and rod - Owner option Shower curtain and rod - Owner option 2' - 1 1 " 2'-0"3" 3'-9½" to centerline of sink/mirror Refer to elevation 3/A6 for additional mirror, lavatory, toilet, and grab bar dimensions 2'-6"2'-6"Roll-over vinyl threshold Ceramic wall tile up to 6'-3"aff with bull-nose cap & epoxy grout Fiberglass Wall Panels 2'-1/4"2'-0" 10 " 2' - 1 " Floor Drain 1'-0" 2' - 1 1 " Bobrick B-5806 grab bars ADA Removable Tub Seat ADA Removable Tub Seat Existing bathtub ADA Removable Tub Seat 2' - 1 1 " 4" 1' - 6 " 3½" Offset ctrls right of tub centerline 2'-0" Hosed shower head on height-adjustable rod Epoxy painted drywall above fiberglass (or alternately run tile full ht) Profile of required knee & toe clearance Schluter DILEX-AHKA typ Schluter DILEX-AHKA typ Epoxy painted drywall above tile (or alternately run tile full ht) Bobrick B-5806 grab bars 4/14/23 Sheet NumberA6 Joseph E Calvin Date Sheet Title Bathroom Interior Elevations March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM 1' - 6 " 5' - 0 " 1' - 6 " 5' - 0 " 16ga aluminum sign to meet all ANSI design requirements Additional van accessible sign at north post Posts supporting upper deck See plan for locations Access Parking Signs1Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0" 6' - 8 " 3'-0" 6' - 8 " 3'-0" 6' - 8 " 2'-0" 6' - 8 " 6' - 1 0 " 6'-0" 6'-4" 1 2 3 4 Door Elevations Scale: 1/4" = 1'-0" 0 1 2 4 6 8 Accessible Room Entrance as see from exterior / push side 16 ga hollow metal door penel, Polyurethane insulation U0.9 or better, Wood frame, Entrance Set (coordinate hardware with Owner), Scope (Du Seung recommended), Overhead Stop, Hinges, ADA Threshold Weatherstripping Qty: 1 like, 1 opposite Stencil sign 6" tall letters in contrasting color KnoxBox model 3200 surface mounted - or as approved by Fire Department5' - 0 " Accessible Bathrooms as see from pull side Solid core wood panel Wood frame Passage Set, Overhead Stop, Hinges, Silencers (no closer) Qty: 1 like, 1 opposite Accessible Bathrooms as see from push side Solid core wood panel Wood frame Passage Set, Wall Stop, Hinges, Silencers Qty: 5 like, 5 opposite Contractor to verify size of each existing opening with door dimensions and verify quantities and swing direction. Sprinkler Entrance as see from exterior / pull side 16 ga hollow metal door panel, Polyurethane insulation U0.9 or better, 14 ga hollow metal frame - insulated, Storeroom Set, Top & bottom rim bolts, Dust-proof lower strike, Hinges, Threshold Weatherstripping Qty: 1 Hardware Functions Passage Set -- Latch bolt always retracts by use of lever from either side. No lock. Lock Set -- When lock is deactivated, latch bolt retracts by use of lever from either side. When lock is activated, latch bolt retracts by use of lever from inside and use of key from outside. Lock is activated/deactivated by use of key from outside or use of button press on inside Entrance Set -- When lock is deactivated, latch bolt retracts by use of lever from either side. When lock is activated, latch bolt retracts by use of lever from inside and use of key from outside. When the button is pressed, the lock is activated, and is thereafter deactivated when either lever is turned. When the button is pressed and rotated, the lock remains activated until the button is turned back to it’s default position. Office Set -- When lock is deactivated, latch bolt retracts by use of lever from either side. When lock is activated, latch bolt retracts by use of lever from inside and use of key from outside. Lock is activated/deactivated by use of key from outside. Lock is activated by use of button on inside and deactivated by turn of lever on inside. Storeroom Set -- Latch bolt retracts by use of key outside or use of lever inside. Outside lever is always inoperative. Inside lever is always free for egress. Privacy Set -- Latch bolt retracts by use of lever from either side unless push- button is activated. The lock is deactivated by either use of lever from the inside of the door, or by use of emergency coin-turn or pin-insert on the outside. Door Notes 1. Field verify all rough openings and finish wall thickness prior to ordering or fabrication of materials. 2. Door elevations indicate typical situations. Consult Architect regarding special conditions if encountered. 3. Contractor to run a continuous bead of sealant around all doors, windows, and other openings or joints. Leave adjacent surfaces clean. Provide backer rod where necessary. 4. Provide hardware finish samples for Owner's selection & Architect's review prior to ordering. All hardware is to meet ANSI/BHMA Grade 1 requirements. Notify Architect of any proposed hardware that does not meet this standard. 5. Provide blocking in framed walls for door stops. 6. Where different floor finishes meet the transition at doors shall occur below door leaf in the closed position. Transitions shall be made using solid aluminum profiles from Schluter Systems with clear finish. 7. Typical gyp bd level of finish is to be #4 on this project except where noted otherwise. Walls to receive tile are to be tile backer board with level #2 finish. Walls to receive epoxy or glossy paint are to be level #5 finish. Ceilings are to be #3 level to receive texture finish and paint. Provide metal drywall corner bead at all exposed gyp bd corners. 8. All interior trim & base boards are to be 1x4 oak unless directed otherwise by Owner. Line of grade Thermal Envelope from NW Scale: 1/2" = 1'-0"n o r t h Thermal Envelope from NW Scale: 1/2" = 1'-0" no r t h Insulation Sect2Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0" Exist roof insulation - loose fill - perhaps vermiculite - approx 4" deep - assuming R10 Pre-existing batt insulation has been removed and is to be replaced with (2) layers of spray-applied closed-cell polyurethane insulation totaling min 3¼" thick - R18 New interior ⅝" gypsum board vapor barrier not required Existing gyp bd ceiling New 1x6 curb/blocking New 8" cellulose loose fill insulation - R28 Existing roof structure - ventilation is at gable ends Existing sheathing and siding Existing sheathing and siding New 3" spray-applied closed-cell polyurethane insulation - R16.5 Floor is not part of thermal envelope - however, recommend installing R30 HD FG batt insulation for sound control New ⅝" gypsum board ceiling Pre-existing batt insulation has been removed and is to be replaced with (2) layers of spray-applied closed-cell polyurethane insulation totaling min 3¼" thick - R18 New interior ⅝" gypsum board - vapor barrier not required Existing deck and rail construction Exist floor decking Existing slab and foundation - assuming not insulated Roof Insulation 2,338 sfZ Add 8" new cellulose insulation Existing R9 + new R28 = total R38 Exterior Framed Walls 3¼" closed-cell polyurethane insul 4,099 sf (incl. area of openings) New R18 Previously Replaced Windows in existing openings 258 sf Assuming Exist U0.35 (2) New Hollow Metal Doors with polyurethane insulation in exist/enlarged openings 40 sf New U0.09 Floor Rim Joist New 3" closed-cell polyurethane 233 sf New R16.5 Existing Below Grade CMU Walls 461 sf - unknown furring/insulation (10) Existing Wood Doors 184 sf - Approx U0.4 See NW drawing above for most thermal insulation values (10) Sliding Glass Doors 440 sf Approx U0.35 New Double Hollow Metal Door with polyurethane insulation in new openings 40 sf New U0.09 Existing sidewalk Refer to Sheet A3 for header and jack stud requirements Fire and STC Ratings 1 April 7, 2023 1 4/14/23 Sheet NumberA7 Joseph E Calvin Date Sheet Title Thermal Envelope & Openings March 21, 2023 of 7 DI S C O V E R Y L O D G E RE M O D E L - P H A S E I 80 0 B i g T h o m p s o n A v e . Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 5 – D I S C O V E R Y L O D G E R E M O D E L - P H A S E I F i l e : " 2 2 2 5 C D " M o d i fi e d : F r i , A p r 1 4 , 2 3 P r i n t : F r i , A p r 1 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : J E C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Approved by SAFEbuilt 04/18/2023 9:30:48 AM THIS ELECTRICAL INSTALLATION MUST CONFORM TO THE 2020 NEC GFCI PROTECTION AS REQUIRED BY 210.8(B) AFCI PROTECTION AS REQUIRED BY 210.12(C) & (D) TAMPER RESISTANCE RECEPTACLES AS REQUIRED BY 406.12 Approved by SAFEbuilt 04/18/2023 9:30:49 AM