HomeMy WebLinkAboutPLANS Remodel 106C W Elkhorn Ave 2022-09-28nort
h
nor
t
h
Work Area
Work Area
Permit Information
Documents and Resources are available
on the project web site…
http://www.intersticearch.com/remmerde/
Electronic Documents
A01 Title Sheet and Project Information
A02 Existing Conditions
A03 Proposed New Construction Plan
A4 East Elevation
A5 Section and Details
Sheet Index
Color Legend
In these drawings colors represent...
Demolition
New Construction
APPLICABLE CODES: 2015 International Building Code (IBC)
AASHTO Bridge Design Manual (LRFD)
MUNICIPALITY:Town of Estes Park
OCCUPANCY AND FLOOR AREAS:
Lower Level East - Group M - Retail Store 3300 sf
Lower Level West - Group A2 - Bar/Tavern 4100 sf
Upper Level - Group R2 - Non-Transient Dormitory 5250 sf
CONSTRUCTION TYPE: Type V-B not sprinklered
BUILDING HEIGHT: Approx 25'-6" (highest ridge above surrounding grade)
STRUCTURAL DESIGN CRITERIA:
Project Elevation: 7500' ±
Ground Snow Load (Pg):
Tabular: 60 psf at 7000'; 70 psf at 8000'
Interpolation: 60 + 10x0.5 = 65 psf
Roof Snow Load:
Importance Factor (Is) = 1.0
Exposure Factor (Ce) = 1.0 (Exposure C)
Thermal Factor (Ct) = 1.1 (Heated Structure)
Pf = 0.7 x Ce x Ct x Is = 0.77 x 65 psf = 51 psf
Pedestrian Live Load: 100 psf
Wind Speed: 171 mph Exposure B
Altitude Correction Factor: 0.81
Seismic Design Category: B
Minimum Roofing Classification: Class B
Project Narrative
To improve egress from upper level dorm rooms, and to protect membrane roofing,
a new steel fabricated roof bridge is proposed to direct upper level occupants
exiting the building in the event of an emergency across a flat roof to the top
landing of an existing exterior exit stair. New materials are to be steel fabricated,
ground smooth, primed and painted for weather protection.
No work is to be performed inside the building, to the exit door, to the exterior
roofing, nor to the the existing stair or landing.
Occupant load estimates on Sheet A02 are estimates based on observed uses
and room configurations. Classifications and floor areas given in the Permit
Information to the right are assumed and estimated.
General
Contractor
Structural
Engineer
Jason Remmerde (970) 290-1290
PO Box 2143 remmerdeconstruction
Estes Park CO 80517 @gmail.com
SKYPOND ENGINEERING
Matthew Khachaturian, PE
312 E Elkhorn Ave
Estes Park, CO 80517
Architect INTERSTICE ARCHITECTURAL STUDIO
Joe Calvin, AIA (970) 420-8264
PO Box 155 joe@intersticearch.com
Estes Park, CO 80517
(504) 940-8278
mtk@skypond
engineering.com
9/16/22
A01
of 5
P# 2218
September 16, 2022
Roof Egress Bridge
110 W Elkhorn Ave, Estes Park, CO
Title Sheet and Project
Information
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
09/28/2022
This structure must comply
with the requirements of the
2020 National Electrical Code
Completely remove
wood decking and
wire mesh railing
Completely remove
wood decking and
wire mesh railing
Membrane Roofing
Neighboring Buildings
Room
201
Room
202
Room
203
Room
204
Room
205
Room
206
Room
207
Room
208
Common
Room
Room
209
Bath
Bath
Room
215
Room
210
Room
216
Room
220
Room
217
West Hallway
North Hallway
Ea
s
t
H
a
l
l
w
a
y
Li
g
h
t
W
e
l
l
Exit stair down to Elkhorn Ave
Exist stair down
to Moraine Ave
FACP
Existing exit door with
panic device - no work
at door itself - serving
approx 17 occupants
1. Occupant Load estimated based on 200 sf per person - 2 people per typical dorm
rooms and 3 people in each of the larger dorm rooms and Common Room.
2. Egress door from the building serves an occupant loads of less than 50 people,
but nevertheless has panic hardware.
3. Completely remove existing wood decking, and wood & wire mesh railing. Prepare
surfaces for new construction illustrated on the following pages.
4. Contractor is responsible for field verifying all dimensions and existing conditions
prior to fabrication of new materials.
General Notes
nor
t
h
Maintain exist
mechanical equipment
No work interior of building
Shown for reference only
Upper Level Demolition Plan
Scale: 3/32" = 1'-0"north
0 4 8 12 16 20
Maintain existing
mechanical equipment
Maintain existing
metal stairway
Maintain existing
membrane roofing
Neighboring building
9/16/22
A02
of 5
P# 2218
September 16, 2022
Roof Egress Bridge
110 W Elkhorn Ave, Estes Park, CO
Existing Conditions
Approved
by
SAFEbuilt
09/28/2022
9:57:45 AM
1
6
'
-
0
"
v
e
r
i
f
y
i
n
f
i
e
l
d
3
'
-
3
"
±
4'-0 ½" VIF
Maintain existing
mechanical equipment
4'-1"±
6°±
Adjust height of south end of assembly
so that step down to membrane roofing
is maximum 7" - estimated at 4¾"
Existing stair landing
approx 8" below surrounding
roof surfaces
1
A05
(2) W8x18 x 16'-0"(VIF) steel beams
Steel Pipe Railings - see Sheet A4
3
A05
3
A05
2
A05
2
A05
Modify first tread shape to accommodate angle
(approx 6°) against building - set elevation of steel
so that top of tread is approx ½" below finish floor
12"W x 1½"D x 4'-0" long 11 ga
plank grate treads - spot weld each
flange to bottom chord of steel beam
A04
Proposed Construction Plan
Scale: 3/8" = 1'-0"north
0 1 2 3 4 5
Configuration should
allow door to open 90°
1. Contractor is responsible for field verifying all dimensions and existing conditions
prior to fabrication of new materials.
2. Do not scale drawings for dimensions. Dimensions are typically to face of
masonry or concrete and face of framing member, unless otherwise noted.
3. Contractors are responsible for all materials and quantities shown in these
drawings graphically as well as those called for by note.
General Notes
Steps down to Moraine Ave
nor
t
h
9/16/22
A03
of 5
P# 2218
September 16, 2022
Roof Egress Bridge
110 W Elkhorn Ave, Estes Park, CO
Proposed New Construction Plan
SECTION 1008
MEANS OF EGRESS ILLUMINATION
1008.1 Means of egress illumination. Illumination shall be
provided in the means of egress in accordance with Section
1008.2. Under emergency power, means of egress illumination
shall comply with Section 1008.3.
Approved
by
SAFEbuilt
09/28/2022
9:57:45 AM
10'-0"3'-0"2'-9"±
2'
-
4
"
10
"
1'
-
6
"
3'
-
2
"
±
2'
-
1
0
¼"
Dimension to
top surface of treads
East Elevation
Scale: 3/8" = 1'-0"
no
r
t
h
0 1 2 3 4 5
1 ½" ϕ steel pipe railings
nominal dimensions shown
Re: General Notes
(2) W8x18 steel beam
installed approximately level
3
A05
2
A05
Existing stair landing
Existing metal open stair treads
Exist roof structure
1. Work shall comply with 2015 IBC
2. Steel pipe railings shall be 1¼" to 1½" ϕ. The top of rails shall be between 34"
and 38" above walking surfaces. Railings shall return to posts or turned toward
walls as illustrated. Changes in railing direction shall be radiused with smooth
transitions - weld and grind joints smooth - prime & paint.
3. New supporting steel beams provide code-required edge protection
General Notes
Neighboring Building
4¾"±
7"
m
a
x
Infill last section of railing
with ½"ϕ steel rod pickets
as shown or alternately wire
mesh or other means of
preventing passage of 4"ϕ
sphere
1
A05
9/16/22
A04
of 5
P# 2218
September 16, 2022
Roof Egress Bridge
110 W Elkhorn Ave, Estes Park, CO
East Elevation
Approved
by
SAFEbuilt
09/28/2022
9:57:45 AM
Grind to radius
exposed corners
of steel flanges
6"x4"x⅜" steel angle x 5" long
with holes for bolts as shown
1" from perimeter and 3" on
center each way
12"W x 1½"D x 4'-0" long 11 ga
plank grate treads
4'-0½"±
Spot weld each flange of treads
to bottom chord of steel beam
W8x18 x 16'-0"(VIF) steel beams
¼"
3'
-
0
¼"±
2'
-
4
"
Steel Pipe Railings - see Sheet A4
Va
r
i
e
s
7"
m
a
x
Bridge Section1Scale: 1" = 1'-0"
0 3"6"1'-0"1'-6"2'-0"
South End Attachment2Not to Scale
North End Attachment3Not to Scale
(4) ¾"ϕ x 8" threaded rods inserted
into Hilti HIT-SC 26x200 epoxy screen
tube sleeves following manufacturer's
installation instructions and timing
(2) ¾" through bolts with either
double nuts or tack weld single nut
Modify first tread shape to accommodate angle
(approx 6°) against building - set elevation of steel
so that top of tread is approx ½" below finish floor
W8x18 x 16'-0"(VIF) steel beams
4"x⅜" steel plate fabrication
with threaded holes through top
plate for rods described above
¾" x 7" threaded rod
Nuts on top and below flange
Steel plate fabrication similar
to that illustrated to right
with 3" offset as shown ¼"
4¾"±
4"
m
i
n
7"
m
a
x
Drill holes for bolts
through flange in field
Drill holes for bolts
through flange in field
W8x18 x 16'-0"(VIF)
steel beams
Beam may be only a faction of an
inch above roofing at north end
Using nuts on threaded rods,
adjust height of bridge so that
step height is between 4" and 7"
Existing step from
roof down to landing
approx 8"
Existing metal stairs
approx 7½" risers
& 10" treads
9/16/22
(2) ¾"x4" lag screws offset
1" from steel corners
4"
1"
8"
1. All steel beams, plates, angles and threaded rod shall be
ASTM A36 steel.
2. All bolts and nuts shall be ASTM A325 steel
3. After assembly, all exposed steel shall be primed and
painted for weather protection.
4. Steel plates within fabrications (detail 2) are to be shop
edge welded using ¼" fillet welds - typical
General Notes
A05
of 5
P# 2218
September 16, 2022
Roof Egress Bridge
110 W Elkhorn Ave, Estes Park, CO
Section and Details
Approved
by
SAFEbuilt
09/28/2022
9:57:45 AM
Approved
by
SAFEbuilt
09/28/2022
9:57:45 AM
See correct loads on A01