HomeMy WebLinkAboutAFFIDAVIT Deck Structure 404 Overlook Ct 2024-04-09
PAGE 1 OF 1
April 9, 2024
MDF Construction
C/O Michael Ferrante
mdfconstruction.mike@gmail.com
RE: Framing Modification;
23-EP-00270 at 316 Overlook Ct.
23-EP-00269 at 416 Overlook Ct.
23-EP-00267 at 314 Overlook Ct.
23-EP-00268 at 414 Overlook Ct.
23-EP-00640 at 318 Overlook Ct.
23-EP-00639 at 320 Overlook Ct.
24-EP-00011 at 408 Overlook Ct.
24-EP-00054 at 402 Overlook Ct.
To Whom it May Concern:
This letter is to certify that I, David A. Bangs (or an employee under my direct supervision) being a duly
licensed engineer in the State of Colorado have reviewed the structural design modifications for the
above referenced project.
In the instances that deck joists meet the ledger at a vent opening, joists are to be tapered cut to a
minimum heel height of 4 ½”. Joists shall be fixed to the ledger with (2)L angles. Ledgers may have 4”
bore holes without further action. On future installations, it is acceptable to terminate the ledger on
either side of the vent opening.
If there are any questions about the construction measures specified above, please don’t hesitate to
contact me at 970-308-8221.
David A Bangs, P.E.
Principal Engineer
Trail Ridge Consulting Engineers