HomeMy WebLinkAboutPLANS 458 Chiquita Ln Residential Remodel 2024-04-022015 IECC
-75% OF LAMPS SHALL BE HIGH EFFICIENCY
-ALL DUCT WORK LOCATED OUTSIDE THE THERMAL
ENVELOPE SHALL BE TESTED FOR LEAKAGE
Inspector to verify that the
plumbing is protected from
freezing.
New bay window to have required
insulation per IECC 2015 an window
U-factor or .32 or better.
Vent dryer to
exterior
This structure must comply
with the requirements of the
2020 National Electrical Code
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
06/14/2023
From:pro source
To:Gary Rusu; CO Plan Review (SB)
Subject:Permit needed for prosource Estes Park Colorado
Date:Tuesday, June 6, 2023 9:37:05 AM
In regards to permit number 23 – EP – 00205
Speaking with Gary here in Estes Park it seems that Anthony that I was dealing with had quit
and my permit has been sitting at lingo… I need to finalize this as soon as possible as this was
filed on May 9. the way I understand is they wanted to know what type of insulation was in
the existing walls of the existing garage that is attached to the house that we are closing into a
storage room. Also they wanted to know how it was heated, the room is being heated by
electric baseboard heaters and I’m attaching pictures of the insulation in the existing walls
which is R13.
Please let me know something as soon as possible thanks dan casey cell 720-340-9339
Approved
by
SAFEbuilt
06/14/2023
8:50:54 AM
Approved
by
SAFEbuilt
06/14/2023
8:50:46 AM
N2
3
°
0
1
'
0
3
"
E
1
3
6
.
8
5
'
(N
2
0
°
4
0
'
1
8
"
E
1
3
5
.
9
'
)
S89°09'42"E 67.70'
(S88°09'42"E 67.7')
S88°12'04"W 33.05'
(S87°45'18"W 33.2')
N6
2
°
0
3
'
1
8
"
W
6
8
.
5
1
'
(N
6
2
°
1
6
'
4
2
"
W
7
0
.
6
'
)
EXISTING
RESIDENCE
DRIVEWAY
(ASPHALT)
EXISTING
DRIVEWAY
(ASPHALT)
S
4
6
°
0
9
'
0
3
"
E
3
6
.
5
3
'
S2
1
°
0
9
'
2
6
"
W
1
9
.
7
2
'
(N
2
0
°
4
0
'
1
8
"
E
2
0
'
)
WORK
SHOP
SHED
458 CHIQUITA LANE
DENNIS & ROBIN SCHALL
BOOK 984 PAGE 44
0.35 ACRES
ZONED E-1
PROPOSED
GARAGE
24'
30
'
30 F
TRIG
H
T
O
F
W
A
Y
25'
B
U
I
L
D
I
N
G
SE
T
B
A
C
K
(TY
P
.
)
20'
31
'
20'
20'
25
'
B
U
I
L
D
I
N
G
SE
T
B
A
C
K
(T
Y
P
.
)
EXISTING
WATER
SERVICE TO
REMAIN
ACCESS EASEMENT
20.
2
'
17.8'
22.0'
12'
1
0
'
1
0
'
COVERED
PLATFORM
20 FOOT SETBACK
VARIANCE APPROVED PER
ESTES PARK BOARD OF
ADJUSTMENT JULY 12,
2022
EXISTING GARAGE
FF ELEV. = 100.00
PROPOSED
ELECTRICAL
SERRVICE
425 CHAPIN LN
ESTES PARK, CO 80517
6" ABOVE GRAE
(NORTH SIDE 16"
ABOVE GRADE)
4' @ 4%
SHEET TITLE:
4 CLIENT:
SHEET
PROJECT TITLE:JLR
1990-001
JOB NO. SHEET
DATE:
SCALE:
07/18/2022
AS SHOWN
APPROVED BY:MST
REVISE GARAGE LOCATION
REVISION:BY:
09/16/2022
CHECKED BY:
DRAWN BY:
DESIGNED BY:
DATE:
MST
MST
MST
DENNY & ROBIN SCHALL
SITE PLAN
458 CHIQUITA LN., ESTES PARK
VARIANCE REQUEST
2019 CORNERSTONE ENGINEERING & SURVEYING, INC.
COPYRIGHT - ALL RIGHTS RESERVED
1692 BIG THOMPSON AVE.
SUITE 200
ESTES PARK, CO 80517
PH: (970) 586-2458
FAX: (970) 586-2459
VICINITY MAP
SITE PLAN
103.50
Approved
by
SAFEbuilt
06/14/2023