HomeMy WebLinkAboutPLANS Footings and Foundation 600 W Elkhorn Ave (Cabin G) 2024-06-05  March 30, 2022  Gary Rusu  Chief Building Official  Town of Estes Park    Re: Elkhorn Lodge Homestead Cabins  Gary,  The following letter is intended to address questions about allowable separations between cabins at the Elkhorn  Lodge development.  Please see the attached site plan markup. West of the main Historic Lodge, there are two clusters of four cabins  each, one to the north (Homestead, D, H + F1‐F4) and one to the south (B, C, E + G). The aggregate area of these  cabin clusters is 4,125sf and 2,270sf respectively. In both cases this is well under the maximum allowable area of  7,000sf for R‐1: NS/S13R per Table 506.2 and so, per IBC 503.1.2 each of these clusters can be considered ‘one  building’ for the purposes of separation. Therefore no limitations exist for the wall ratings and openings between  cabins.   In terms of the separation between the cabin clusters and the existing Historic Lodge, per Table 602, a separation  distance greater than 10‐feet for a type V‐B building, R‐1 occupancy would result in 0‐hour rating requirement. Per  Table 705.8, a separation distance of at least 10‐feet would result in a maximum wall opening percentage of 15%  for the cabins (UP/NS). As proposed, the east wall of cabin F1‐F4 has no openings and the east walls of cabins C  and H have 10% of the wall area as openings. Since the Historic Lodge is proposed to have a full NFPA13  suppression system installed, 45% of the west walls adjacent to the cabins could be open, although as proposed,  open area is substantially less. Eaves for all buildings are not required to be fire‐resistance rated per 705.2.3, as all  would be greater than 5‐feet from the assumed property line between buildings.  Based on the above, the cabins should be separated from the Historic Lodge by at least 20‐feet. Note that the  measurement is taken perpendicular to the cabin walls – so, for example, cabins F1‐F4 appear to be in compliance.  Cabin C should be shifted west, with the corresponding dimensions between remaining cabins adjusted  accordingly.  Thank you for your time and consideration during your review of this information. Please let me know if there is  any further clarification required from me.  Respectfully,  Steve Lane, AIA LEED AP  c: Justin Mabey, HS Estes Park, LLC  Joe Coop, VanHorn Engineering  Jerry Szulim, DB+B Construction  10/21/201103/31/2022 Reviewed by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 04/14/2022 min +20' 10.5' 10.5' 10.5' 21.4' 1500sf 650sf 875sf 1100sf 4,125sf Aggregate 660sf 450sf 500sf 660sf 2,270sf Aggregate (4) CABINS CONSIDERED 'ONE' BUILDING PER IBC 503.1.2 (4) CABINS CONSIDERED 'ONE' BUILDING PER IBC 503.1.2 20'+ ALLOWS 15% OF CABIN EAST WALLS TO BE OPENINGS, (typ of 3) Reviewed by SAFEbuilt 04/14/2022 Reviewed by SAFEbuilt 04/14/2022 10/28/2021 Reviewed by SAFEbuilt 04/14/2022 10/28/2021 Reviewed by SAFEbuilt 04/14/2022