Loading...
HomeMy WebLinkAboutDOCUMENT Heating and AC 2010 Cherokee Dr 2022-10-22Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Load Short Form November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Information InfiltrationClgHtg SimplifiedMethod84-10Outside db (°F) AverageConstruction quality7572Inside db (°F) 0Fireplaces982Design TD (°F) H-Daily range 5030Inside humidity (%) -1143Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade Carrier Infinity 98 Modulating...Trade CARRIER Model 59MN7B080C21--20 Cond 24VNA937A0030 AHRI ref 0 Coil CNPVP3621ALA+59MN7B080C21--20+UI AHRI ref 203685122 Efficiency 97.2 AFUE Efficiency 12.2 EER, 17.5 SEER Heating input Btuh80000 Sensible cooling Btuh22260 Heating output Btuh54600 Latent cooling Btuh9540 Temperature rise °F55 Total cooling Btuh31800 Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.076 Static pressure in H2O1.00 Static pressure in H2O1.00 Space thermostat Load sensible heat ratio 0.99 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Master p 542 9146 3954 267 300 Main Level p 1448 21488 11924 626 904 Basement p 1453 10526 4313 307 327 Entire House d 3443 41160 15170 1200 1200 Other equip loads 3788 416 Equip. @ 0.89 RSM 13871 Latent cooling 126 TOTALS 3443 44948 13997 1200 1200 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Load Short Form November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Information InfiltrationClgHtg SimplifiedMethod84-10Outside db (°F) AverageConstruction quality7572Inside db (°F) 0Fireplaces982Design TD (°F) H-Daily range 5030Inside humidity (%) -1143Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech/Stor 128 1160 0 34 0 Bedroom 2 210 2153 1538 63 117 Clo 2 42 429 0 12 0 Bath 2 56 0 0 0 0 Bath 3 92 504 0 15 0 TV Room 230 807 857 24 65 B Hall/Stair 305 1866 0 54 0 Bedroom 3 209 1764 886 51 67 Office 181 1845 1031 54 78 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W Basement p 1453 10526 4313 307 327 Other equip loads 0 0 Equip. @ 0.89 RSM 3838 Latent cooling 400 TOTALS 1453 10526 4238 307 327 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Load Short Form November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Information InfiltrationClgHtg SimplifiedMethod84-10Outside db (°F) AverageConstruction quality7572Inside db (°F) 0Fireplaces982Design TD (°F) H-Daily range 5030Inside humidity (%) -1143Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Kitchen 244 2014 2034 59 154 Stair/Hall 306 3393 730 99 55 Great Room 481 9298 5456 271 414 Dining 181 3154 1850 92 140 Mud 115 1348 249 39 19 Laundry 77 1626 1328 47 101 Powder 45 656 277 19 21 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 5 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W Main Level p 1448 21488 11924 626 904 Other equip loads 0 0 Equip. @ 0.89 RSM 10613 Latent cooling 0 TOTALS 1448 21488 10613 626 904 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 6 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Load Short Form November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Information InfiltrationClgHtg SimplifiedMethod84-10Outside db (°F) AverageConstruction quality7572Inside db (°F) 0Fireplaces982Design TD (°F) H-Daily range 5030Inside humidity (%) -1143Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Master Bedroom 285 5899 2709 172 205 WIC 108 2576 1044 75 79 Master Bath 149 670 201 20 15 Master p 542 9146 3954 267 300 Other equip loads 0 0 Equip. @ 0.89 RSM 3519 Latent cooling 290 TOTALS 542 9146 3809 267 300 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Loads for Multiple Orientations November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)15826 16791 14597 14939 14309 14762 13871 15639 Latent Load (Btuh)126 126 126 126 126 126 126 126 Total Load (Btuh)15951 16917 14723 15064 14435 14888 13997 15765 Heating AVF (cfm)1200 1200 1200 1200 1200 1200 1200 1200 Cooling AVF (cfm)1200 1200 1200 1200 1200 1200 1200 1200 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 5000 10000 15000 20000 N NE E SE S SW W NW Front Door faces WestCurrent Orientation: Front Door faces NortheastHighest Cooling Load: Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Loads for Multiple Orientations November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)3922 4278 4365 4107 3385 3026 3519 3914 Latent Load (Btuh)290 290 290 290 290 290 290 290 Total Load (Btuh)4213 4568 4655 4397 3675 3316 3809 4204 Heating AVF (cfm)267 267 267 267 267 267 267 267 Cooling AVF (cfm)290 310 366 336 281 250 300 284 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 1000 2000 3000 4000 5000 N NE E SE S SW W NW Front Door faces WestCurrent Orientation: Front Door faces EastHighest Cooling Load: Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Loads for Multiple Orientations November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)10755 9729 8373 8511 8923 10489 10613 11434 Latent Load (Btuh)0 0 0 0 0 0 0 0 Total Load (Btuh)10755 9729 8373 8511 8923 10489 10613 11434 Heating AVF (cfm)626 626 626 626 626 626 626 626 Cooling AVF (cfm)794 705 701 696 740 867 904 829 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 5000 10000 15000 N NE E SE S SW W NW Front Door faces WestCurrent Orientation: Front Door faces NorthwestHighest Cooling Load: Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Loads for Multiple Orientations November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)4272 4112 3379 2875 3315 3777 3838 4183 Latent Load (Btuh)400 400 400 400 400 400 400 400 Total Load (Btuh)4672 4512 3779 3275 3715 4177 4238 4583 Heating AVF (cfm)307 307 307 307 307 307 307 307 Cooling AVF (cfm)315 298 283 235 275 312 327 303 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 1000 2000 3000 4000 5000 N NE E SE S SW W NW Front Door faces WestCurrent Orientation: Front Door faces NorthHighest Cooling Load: Bold/italic values have been manually overridden 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Building Analysis November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing DoorsCeilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 26.6119773.7Walls 24.41098223.2Glazing 2.3103349.2Doors 7.232361.6Ceilings 11.551732.62.6Floors 19.587594.6Infiltration 00Ducts 00Piping 00Humidification 8.43788Ventilation0Adjustments 100.044948Total Cooling Walls Glazing Other Ceilings Floors Infiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 4.57060.2Walls 46.7727515.4Glazing 1.31959.3Doors 9.915390.8Ceilings 3.55410.3Floors 3.24940.3Infiltration 00Ducts 2.7416Ventilation 28.44420Internal gains 00Blower 0Adjustments 100.015585Total Latent Cooling Load = 126 Btuh Overall U-va lue = 0.0 52 Btuh/ft²-°F Data entries checked. Bold/italic values have been manually overridden 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Building Analysis November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Floors % of loadBtuhBtuh/ft²Component 49.952573.4Walls 20.6217023.0Glazing 000Doors 000Ceilings 29.431002.12.1Floors 000Infiltration 00Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.010526Total Cooling Glazing Internal Gains % of loadBtuhBtuh/ft²Component 000Walls 68.5295331.2Glazing 000Doors 000Ceilings 000Floors 000Infiltration 00Ducts 00Ventilation 31.51360Internal gains 00Blower 0Adjustments 100.04313Total Latent Cooling Load = 400 Btuh Overall U-va lue = 0.0 43 Btuh/ft²-°F Data entries checked. Bold/italic values have been manually overridden 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Building Analysis November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Other Infiltration % of loadBtuhBtuh/ft²Component 23.349983.9Walls 30.8661523.4Glazing 4.8103349.2Doors 11.023551.6Ceilings 1.73573.73.7Floors 28.561304.6Infiltration 00Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.021488Total Cooling Walls Glazing Other Ceilings Infiltration Internal Gains % of loadBtuhBtuh/ft²Component 4.14850.4Walls 59.4708525.0Glazing 1.61959.3Doors 9.411200.8Ceilings 0.8931.0Floors 2.93460.3Infiltration 00Ducts 00Ventilation 21.82600Internal gains 00Blower 0Adjustments 100.011924Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 60 Btuh/ft²-°F Data entries checked. Bold/italic values have been manually overridden 2022-Nov-21 17:31:21 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Building Analysis November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Floors Infiltration % of loadBtuhBtuh/ft²Component 18.817223.6Walls 24.0219823.1Glazing 000Doors 9.68811.6Ceilings 18.817173.73.7Floors 28.726294.6Infiltration 00Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.09146Total Cooling Walls Glazing Ceilings Floors Infiltration Internal Gains % of loadBtuhBtuh/ft²Component 5.62200.5Walls 57.1225923.8Glazing 000Doors 10.64190.8Ceilings 11.34481.0Floors 3.71480.3Infiltration 00Ducts 00Ventilation 11.6460Internal gains 00Blower 0Adjustments 100.03954Total Latent Cooling Load = 290 Btuh Overall U-va lue = 0.0 53 Btuh/ft²-°F Data entries checked. Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Component Constructions November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B13-0wc-10: Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, r-13 cav ins, 8" thk, 1/2" gypsum board int fnsh 0012953.6913.00.045351n 0013853.3113.00.045419e 008832.9713.00.045297s 0016943.6913.00.045459w 0052573.4513.00.0451526all Exterior Wall - R21R5wood2022: Frm wall, wd ext, 5/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1180.479213.6526.00.044253n 2420.4718903.6526.00.044518e 2030.4715813.6526.00.044434s 1430.4711203.6526.00.044307w 7060.4755123.6526.00.0441511all Partitions 12F-0sw: Frm wall, 5/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 0012075.3321.00.065227 Windows Exterior Glass Door - 2929 2020: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/2" gap, 1/8" thk; 50% outdoor insect screen; 7 ft head ht 1557.3649923.800.29021n 28113.449923.800.29021s 43510.499923.800.29042all Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 12 ft overhang (8 ft window ht, 2 ft sep.); 7 ft head ht 597.3619023.800.2908n Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 8 ft head ht 3417.11110223.000.28048n 209226.0184823.000.28081e 85812.9152723.000.28067s 329116.9447723.000.280195all Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 7 ft head ht 116928.993023.000.28041e 77414.3124023.000.28054s 194420.6217023.000.28095all Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 7 ft head ht 53826.947623.800.29020e Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Right-Suite® Universal 2022 22.0.01 RSU15461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 40113.471323.800.29030s 1557.3649923.800.29021w 3097.3699923.800.29042w 4647.36149823.800.29063all 1427.1145923.000.28020w 1959.30103349.26.30.60021n 15390.7732361.6349.00.0201990 310017.210.00.210180 00 Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 10.5 ft head ht Exterior Glass Door - 2929 2020: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/2" gap, 1/8" thk; 50% outdoor insect screen; 9 ft overhang (7 ft window ht, 2 ft sep.); 7 ft head ht Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 9 ft overhang (4 ft window ht, 2 ft sep.); 8 ft head ht Doors 11J0: Door, mtl fbrgl type Ceilings Roof-R49: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh Floors 22B-10tpl: Bg floor, light dry soil, 4' depth, r-10 edge ins Main Level Floor at crawlspace - wood floor R-19 2022A: Flr floor, frm flr, 10" thkns, hrd wd flr fnsh, tight crwl ovr, r-19 wall insul 5410.9520743.6619.00.053567 Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Right-Suite® Universal 2022 22.0.01 RSU15461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Component Constructions November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bulb (°F) SimplifiedMethod)H(30-Daily range (°F) AverageConstruction quality62-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Exterior Wall - R21R5wood2022: Frm wall, wd ext, 5/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 620.474873.6526.00.044134n 930.477263.6526.00.044199e 420.473283.6526.00.04490s 230.471813.6526.00.04450w 2200.4717223.6526.00.044472all Partitions (none) Windows Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 8 ft head ht 2677.1186123.000.28038n 97526.086123.000.28038e 124116.5172223.000.28075all Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 7 ft head ht 53826.947623.800.29020e Doors (none) Ceilings Roof-R49: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh 4190.778811.6349.00.020542 Floors Main Level Floor at crawlspace - wood floor R-19 2022A: Flr floor, frm flr, 10" thkns, hrd wd flr fnsh, tight crwl ovr, r-19 wall insul 4480.9517173.6619.00.053470 Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Component Constructions November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) SimplifiedMethod)H(30-Da ily ra nge (°F) AverageConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Exterior Wall - R21R5wood2022: Frm wall, wd ext, 5/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 560.474343.6526.00.044119n 1490.4711643.6526.00.044319e 1600.4712533.6526.00.044344s 1200.479393.6526.00.044258w 4850.4737903.6526.00.0441039all Partitions 12F-0sw: Frm wall, 5/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 0012075.3321.00.065227 Windows Exterior Glass Door - 2929 2020: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/2" gap, 1/8" thk; 50% outdoor insect screen; 7 ft head ht 1557.3649923.800.29021n 28113.449923.800.29021s 43510.499923.800.29042all Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 12 ft overhang (8 ft window ht, 2 ft sep.); 7 ft head ht 597.3619023.800.2908n Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 8 ft head ht 757.1124123.000.28011n 111726.098723.000.28043e 85812.9152723.000.28067s 205017.1275523.000.280120all Window - Fixed - 2929: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 10.5 ft head ht 40113.471323.800.29030s Exterior Glass Door - 2929 2020: 2 glazing, clr low-e outr, air gas, wd frm mat, clr innr, 1/2" gap, 1/8" thk; 50% outdoor insect screen; 9 ft overhang (7 ft window ht, 2 ft sep.); 7 ft head ht 1557.3649923.800.29021w 3097.3699923.800.29042w 4647.36149823.800.29063all Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 50% outdoor insect screen; 9 ft overhang (4 ft window ht, 2 ft sep.); 8 ft head ht 1427.1145923.000.28020w Doors 11J0: Door, mtl fbrgl type 1959.30103349.26.30.60021n Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 5 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W Ceilings Roof-R49: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh 11200.7723551.6349.00.0201448 Floors Main Level Floor at crawlspace - wood floor R-19 2022A: Flr floor, frm flr, 10" thkns, hrd wd flr fnsh, tight crwl ovr, r-19 wall insul 930.953573.6619.00.05398 Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Right-Suite® Universal 2022 22.0.01 RSU15461 Page 6 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Component Constructions November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bulb (°F) SimplifiedMethod)H(30-Daily range (°F) AverageConstruction quality62-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² 0012953.6913.00.045351n 0013853.3113.00.045419e 008832.9713.00.045297s 0016943.6913.00.045459w 0052573.4513.00.0451526all 116928.993023.000.28041e 77414.3124023.000.28054s 194420.6217023.000.28095all Construction descriptions Walls 15B13-0wc-10: Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, r-13 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows Window - Operable - 2828 2019: 2 glazing, clr low-e outr, air gas, clad wd frm mat, clr innr, 1/4" gap, 1/8" thk; 7 ft head ht Doors (none) Ceilings (none) Floors 22B-10tpl: Bg floor, light dry soil, 4' depth, r-10 edge ins 310017.210.00.210180 00 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22 Right-Suite® Universal 2022 22.0.01 RSU15461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Project Summary November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor:2010 Cherokee Drive, Estes Park - Larimer County, CO Notes: Design Information Craig, Creig-Moffit Field, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-10 Outside db °F84Inside db °F72 Inside db °F75 Design TD °F82 Design TD °F9Daily range H Relative humidity %50Moisture difference gr/lb-11 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh41160 Structure Btuh15170 Ducts Btuh0 Ducts Btuh0Central vent (56 cfm)3788 Btuh Central vent (56 cfm)Btuh416 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh44948 Use manufacturer's data n Rate/swing multiplier 0.89InfiltrationEquipment sensible load Btuh13871 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh434 Ducts Btuh0Central vent (56 cfm)Btuh-308 CoolingHeating Outside air34433443Area (ft²)Equipment latent load Btuh126 2081720817Volume (ft³)Air changes/hour 0.190.37 Equipment Total Load (Sen+Lat)Btuh13997 Equiv. AVF (cfm)66128 Req. total capacity at 0.70 SHR ton1.7 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make CarrierTradeCarrier Infinity 98 Modulating...Trade CARRIER Model 59MN7B080C21--20 Cond 24VNA937A0030AHRI ref 0 Coil CNPVP3621ALA+59MN7B080C21--20+UI AHRI ref 203685122Efficiency97.2 AFUE Efficiency 12.2 EER, 17.5 SEER Heating input Btuh80000 Sensible cooling Btuh22260Heating output Btuh54600 Latent cooling Btuh9540 Temperature rise °F55 Total cooling Btuh31800Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.076Static pressure in H2O1.00 Static pressure in H2O1.00 Space thermostat Load sensible heat ratio 0.99 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Project Summary November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor:2010 Cherokee Drive, Estes Park - Larimer County, CO Notes: Design Information Craig, Creig-Moffit Field, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-10 Outside db °F84Inside db °F72 Inside db °F75 Design TD °F82 Design TD °F9Daily range H Relative humidity %50Moisture difference gr/lb-11 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh10526 Structure Btuh4313 Ducts Btuh0 Ducts Btuh0Central vent (23 cfm)0 Btuh Central vent (23 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh10526 Use manufacturer's data n Rate/swing multiplier 0.89InfiltrationEquipment sensible load Btuh3838 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh400 Ducts Btuh0Central vent (23 cfm)Btuh0 CoolingHeating14531453Area (ft²)Equipment latent load Btuh400 504504Volume (ft³)Air changes/hour 00 Equipment Total Load (Sen+Lat)Btuh4238 Equiv. AVF (cfm)00 Req. total capacity at 0.70 SHR ton0.5 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/a Model n/a Cond n/aAHRI ref n/a Coil n/a AHRI ref n/aEfficiencyn/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Project Summary November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor:2010 Cherokee Drive, Estes Park - Larimer County, CO Notes: Design Information Craig, Creig-Moffit Field, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-10 Outside db °F84Inside db °F72 Inside db °F75 Design TD °F82 Design TD °F9Daily range H Relative humidity %50Moisture difference gr/lb-11 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh21488 Structure Btuh11924 Ducts Btuh0 Ducts Btuh0Central vent (23 cfm)0 Btuh Central vent (23 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh21488 Use manufacturer's data n Rate/swing multiplier 0.89InfiltrationEquipment sensible load Btuh10613 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-256 Ducts Btuh0Central vent (23 cfm)Btuh0 CoolingHeating14481448Area (ft²)Equipment latent load Btuh0 1544015440Volume (ft³)Air changes/hour 0.180.35 Equipment Total Load (Sen+Lat)Btuh10613 Equiv. AVF (cfm)4690 Req. total capacity at 0.70 SHR ton1.3 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/a Model n/a Cond n/aAHRI ref n/a Coil n/a AHRI ref n/aEfficiencyn/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Project Summary November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor:2010 Cherokee Drive, Estes Park - Larimer County, CO Notes: Design Information Craig, Creig-Moffit Field, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-10 Outside db °F84Inside db °F72 Inside db °F75 Design TD °F82 Design TD °F9Daily range H Relative humidity %50Moisture difference gr/lb-11 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh9146 Structure Btuh3954 Ducts Btuh0 Ducts Btuh0Central vent (9 cfm)Btuh0 Central vent (9 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh9146 Use manufacturer's data n Rate/swing multiplier 0.89InfiltrationEquipment sensible load Btuh3519 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh290 Ducts Btuh0Central vent (9 cfm)Btuh0 CoolingHeating542542Area (ft²)Equipment latent load Btuh290 48744874Volume (ft³)Air changes/hour 0.240.47 Equipment Total Load (Sen+Lat)Btuh3809 Equiv. AVF (cfm)2039 Req. total capacity at 0.70 SHR ton0.4 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/a Model n/a Cond n/aAHRI ref n/a Coil n/a AHRI ref n/aEfficiencyn/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:AED Assessment November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 23.9%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:AED Assessment November 22, 2022Date:Basement TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 31.0%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1009 Btuh (PFG - ALP) Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:AED Assessment November 22, 2022Date:Main Level TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 40.5%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 3533 Btuh (PFG - ALP) Bold/italic values have been manually overridden 2022-Nov-21 17:31:22 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:AED Assessment November 22, 2022Date:Master TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Craig, Creig-Moffit Field, CO, US 982Design TD (°F)ft7522Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-10.842.9Moisture difference (gr/lb)CoolingHeating Infiltration:84-10Dry bul b (°F) )H(30-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 36.1%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 479 Btuh (PFG - ALP) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Entire House TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Entire House Master 2 Exposed wall 390.9 ft 63.0 ft 3 Room height 9.7 dft 9.0 pft 4 Room dimensions 5 Room area 3442.6 f t²541.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 351 351 1295 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 330 253 921 118 171 134 487 62 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 21 0 499 155 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 8 0 190 59 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 48 0 1102 341 38 0 861 267 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 459 419 1385 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 41 0 930 1169 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 619 518 1890 242 257 199 726 93 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 23.7823.78 26.9226.92 20 0 476 538 20 0 476 538 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 81 0 1848 2092 38 0 861 975 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 351 297 883 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 54 0 1240 774 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 551 434 1581 203 90 90 328 42 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 21 0 499 281 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 30 0 713 401 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 67 0 1527 858 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 459 459 1694 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 390 307 1120 143 50 50 181 23 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 21 16 499 155 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 42 32 999 309 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 20 20 459 142 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 248 227 1207 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 21 21 1033 195 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 1990 1990 3236 1539 542 542 881 419 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 1453 180 3100 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 567 567 2074 541 470 470 1717 448 6 c) AED excursion 0 479 Envelope loss/gain 32401 10256 6517 3346 12 a)Infiltration 8759 494 2629 148 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 2 460 Appliances/other 3500 0 Subtotal (lines 6 to 13)41160 15170 9146 3954 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 41160 15170 9146 3954 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 41160 15170 9146 3954 Air required (cfm)Air required (cfm)1200 1200 267 300 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 2...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Entire House TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Main Level Basement 2 Exposed wall 147.9 ft 180.0 ft 3 Room height 10.7 pft 9.0 pft 4 Room dimensions 5 Room area 1448.4 f t²1452.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 0 0 0 0 351 351 1295 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 159 119 434 56 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 21 0 499 155 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 8 0 190 59 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 11 0 241 75 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 0 0 0 0 459 419 1385 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 0 0 0 0 41 0 930 1169 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 362 319 1164 149 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 23.7823.78 26.9226.92 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 43 0 987 1117 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 0 0 0 0 351 297 883 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 0 0 0 0 54 0 1240 774 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 461 344 1253 160 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 21 0 499 281 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 30 0 713 401 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 67 0 1527 858 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 0 0 0 0 459 459 1694 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 341 258 939 120 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 21 16 499 155 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 42 32 999 309 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 20 20 459 142 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 248 227 1207 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 21 21 1033 195 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 1448 1448 2355 1120 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 0 0 0 0 1453 180 3100 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 98 98 357 93 0 0 0 0 6 c) AED excursion 3533 1009 Envelope loss/gain 15358 8979 10526 2953 12 a)Infiltration 6130 346 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 2600 900 Subtotal (lines 6 to 13)21488 11924 10526 4313 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 21488 11924 10526 4313 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 21488 11924 10526 4313 Air required (cfm)Air required (cfm)626 904 307 327 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 3...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Basement TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Basement Mech/Stor 2 Exposed wall 180.0 ft 23.0 ft 3 Room height 9.0 pft 9.0 heat/coolft 4 Room dimensions ft13.5x9.5 5 Room area 1452.8 f t²128.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 351 351 1295 0 122 122 448 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 459 419 1385 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 41 0 930 1169 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 351 297 883 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 54 0 1240 774 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 459 459 1694 0 86 86 315 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 1453 180 3100 0 128 23 396 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 1009 0 Envelope loss/gain 10526 2953 1160 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)10526 4313 1160 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 10526 4313 1160 0 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 10526 4313 1160 0 Air required (cfm)Air required (cfm)307 327 34 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 4...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Basement TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Bedroom 2 Clo 2 2 Exposed wall 29.0 ft 8.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft15.0x14.0 ft7.0x6.0 5 Room area 210.0 f t²42.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 126 104 293 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 23 0 517 650 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 135 113 327 0 63 63 232 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 23 0 517 323 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 0 0 0 0 14 14 50 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 210 29 499 0 42 9 146 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 336 0 Envelope loss/gain 2153 1308 429 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2153 1538 429 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2153 1538 429 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2153 1538 429 0 Air required (cfm)Air required (cfm)63 117 12 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 5...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Basement TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Bath 2 Bath 3 2 Exposed wall 0 ft 10.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft7.0x8.0 ft11.5x8.0 5 Room area 56.0 f t²92.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 0 0 0 0 18 18 66 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 0 0 0 0 72 72 266 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 56 0 0 0 92 10 172 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 0 0 504 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)0 0 504 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 0 0 504 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 504 0 Air required (cfm)Air required (cfm)0 0 15 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 6...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Basement TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name TV Room B Hall/Stair 2 Exposed wall 16.0 ft 37.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft229.6x1.0 ft304.6x1.0 5 Room area 229.6 f t²304.6 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 0 0 0 0 72 72 266 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 0 0 0 0 135 135 498 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 23 23 83 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 122 122 448 0 126 126 465 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 230 16 276 0 305 37 637 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -43 0 Envelope loss/gain 807 -43 1866 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)807 857 1866 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 807 857 1866 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 807 857 1866 0 Air required (cfm)Air required (cfm)24 65 54 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 7...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Basement TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Bedroom 3 Office 2 Exposed wall 29.5 ft 27.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft209.0x1.0 ft14.5x12.5 5 Room area 209.0 f t²181.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 3.693.69 0.000.00 140 140 515 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 3.313.31 0.000.00 126 108 328 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 28.8828.88 18 0 413 520 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 2.972.97 0.000.00 0 0 0 0 131 99 241 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 14.3414.34 0 0 0 0 32 0 723 452 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 3.693.69 0.000.00 0 0 0 0 113 113 415 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10tpl22B-10tpl 0.2100.210 --17.2217.22 0.000.00 209 30 508 0 181 27 465 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 137 580 Envelope loss/gain 1764 656 1845 1031 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1764 886 1845 1031 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1764 886 1845 1031 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1764 886 1845 1031 Air required (cfm)Air required (cfm)51 67 54 78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 8...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Main Level TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Main Level Kitchen 2 Exposed wall 147.9 ft 16.5 ft 3 Room height 10.7 pft 9.0 heat/coolft 4 Room dimensions ft244.3x1.0 5 Room area 1448.4 f t²244.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 159 119 434 56 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 21 0 499 155 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 8 0 190 59 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 11 0 241 75 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 362 319 1164 149 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 43 0 987 1117 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 461 344 1253 160 23 23 82 11 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 21 0 499 281 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 30 0 713 401 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 67 0 1527 858 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 341 258 939 120 126 106 387 50 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 21 16 499 155 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 42 32 999 309 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 20 20 459 142 20 20 459 142 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 248 227 1207 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 21 21 1033 195 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 1448 1448 2355 1120 244 244 397 189 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 98 98 357 93 0 0 0 0 6 c) AED excursion 3533 404 Envelope loss/gain 15358 8979 1325 795 12 a)Infiltration 6130 346 689 39 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 2600 1200 Subtotal (lines 6 to 13)21488 11924 2014 2034 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 21488 11924 2014 2034 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 21488 11924 2014 2034 Air required (cfm)Air required (cfm)626 904 59 154 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 9...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Main Level TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Stair/Hall Great Room 2 Exposed wall 28.5 ft 47.4 ft 3 Room height 9.0 heat/coolft 14.0 heat/coolft 4 Room dimensions ft305.8x1.0 ft480.9x1.0 5 Room area 305.8 f t²480.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 131 91 332 43 28 28 102 13 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 21 0 499 155 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 8 0 190 59 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 11 0 241 75 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 0 0 0 0 308 272 992 127 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 0 0 0 0 36 0 827 936 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 0 0 0 0 308 191 695 89 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 21 0 499 281 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 30 0 713 401 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 0 0 0 0 67 0 1527 858 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 0 0 0 0 21 21 77 10 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 126 126 672 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 306 306 497 236 481 481 782 372 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 98 98 357 93 0 0 0 0 6 c) AED excursion 36 1296 Envelope loss/gain 2788 696 6214 4382 12 a)Infiltration 605 34 3084 174 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13)3393 730 9298 5456 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3393 730 9298 5456 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3393 730 9298 5456 Air required (cfm)Air required (cfm)99 55 271 414 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 10...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Main Level TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Dining Mud 2 Exposed wall 27.0 ft 5.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.5x12.5 ft114.8x1.0 5 Room area 181.3 f t²114.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 131 131 476 61 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 113 71 257 33 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 42 32 999 309 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 0 0 0 0 45 24 128 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 0 0 0 0 21 21 1033 195 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 181 181 295 140 115 115 187 89 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 0 0 0 0 0 0 0 0 6 c) AED excursion 1244 -35 Envelope loss/gain 2027 1787 1348 249 12 a)Infiltration 1127 64 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3154 1850 1348 249 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3154 1850 1348 249 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3154 1850 1348 249 Air required (cfm)Air required (cfm)92 140 39 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 11...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Main Level TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Laundry Powder 2 Exposed wall 17.5 ft 6.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.5x9.0 ft7.5x6.0 5 Room area 76.5 f t²45.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 0 0 0 0 54 47 171 22 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 0 0 0 0 7 0 161 182 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 23.7823.78 13.3613.36 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 22.9622.96 12.9012.90 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 81 60 219 28 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 21 16 499 155 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 23.7823.78 7.367.36 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.335.33 0.000.00 77 77 408 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 49.2049.20 9.309.30 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 77 77 124 59 45 45 73 35 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 0 0 0 0 0 0 0 0 6 c) AED excursion 565 24 Envelope loss/gain 1250 807 405 263 12 a)Infiltration 376 21 250 14 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)1626 1328 656 277 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1626 1328 656 277 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1626 1328 656 277 Air required (cfm)Air required (cfm)47 101 19 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 12...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Master TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name Master Master Bedroom 2 Exposed wall 63.0 ft 39.5 ft 3 Room height 9.0 pft 9.0 heat/coolft 4 Room dimensions ft19.0x15.0 5 Room area 541.5 f t²285.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 171 134 487 62 171 134 487 62 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 38 0 861 267 38 0 861 267 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 257 199 726 93 135 98 356 46 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 23.7823.78 26.9226.92 20 0 476 538 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 38 0 861 975 38 0 861 975 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 90 90 328 42 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 50 50 181 23 50 50 181 23 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 542 542 881 419 285 285 463 220 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 470 470 1717 448 285 285 1042 272 6 c) AED excursion 479 292 Envelope loss/gain 6517 3346 4251 2156 12 a)Infiltration 2629 148 1648 93 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)9146 3954 5899 2709 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 9146 3954 5899 2709 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 9146 3954 5899 2709 Air required (cfm)Air required (cfm)267 300 172 205 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Nov-21 17:31:22Right-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 13...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Right-J® W or ksheet November 22, 2022Date:Master TCBy:10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com 1 Room name WIC Master Bath 2 Exposed wall 21.5 ft 2.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.0x13.5 ft11.0x13.5 5 Room area 108.0 f t²148.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 nn 3.653.65 0.470.47 0 0 0 0 0 0 0 0 .GG Exterior Glass Door 0.290Exterior Glass Door 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 GG Window - Operable -0.280Window - Operable -0.280 nn 22.9622.96 7.117.11 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ee 3.653.65 0.470.47 122 102 370 47 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ee 23.7823.78 26.9226.92 20 0 476 538 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ee 22.9622.96 25.9925.99 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ss 3.653.65 0.470.47 72 72 263 34 18 18 66 8 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Fixed - 292 0.290Window - Fixed - 292 0.290 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B13-0wc-1015B13-0wc-10 0.0930.093 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Exterior Wall - R21R 0.044Exterior Wall - R21R 0.044 ww 3.653.65 0.470.47 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Exterior Glass Door 0.290Exterior Glass Door 0.290 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Window - Operable -0.280Window - Operable -0.280 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD 11J011J0 0.6000.600 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC Roof-R49Roof-R49 0.0200.020 --1.631.63 0.770.77 108 108 176 84 149 149 241 115 FF 22B-10tpl22B-10tpl 0.2100.210 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Main Level Floor at 0.053Main Level Floor at 0.053 --3.663.66 0.950.95 108 108 395 103 77 77 280 73 6 c) AED excursion 188 0 Envelope loss/gain 1679 994 587 196 12 a)Infiltration 897 51 83 5 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2576 1044 670 201 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2576 1044 670 201 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2576 1044 670 201 Air required (cfm)Air required (cfm)75 79 20 15 2022-Nov-21 17:31:24 Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Page 1 ...nce - Manual JS - Tri-City - Larimer County.rup Calc = MJ8 Front Door faces: W 2010 Cherokee DriveJob:Manual S Compliance Report November 22, 2022Date:Entire House TCBy: 10-10-22Plan:Tri-City Heating and Air Conditioning, Inc. P.O. Box 271972, Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 Email: tricityhvac@yahoo.com Project Information Friedman ResidenceFor: 2010 Cherokee Drive, Estes Park - Larimer County, CO Cooling Equipment Design Conditions °F75.4Entering coil DB:Btuh15585Sensible gain:°F84.0Outdoor design DB: °F61.4Entering coil WB:Btuh126Latent gain:°F62.0Outdoor design WB: Btuh15711Total gain:°F75.0Indoor design DB: cfm1200Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 24VNA937A0030+CNPVP3621ALA+59MN7B080C21--20+UIModel:CarrierManufacturer: cfm1200Actual airflow: % of load107Btuh16695Sensible capacity: % of load5691Btuh7155Latent capacity: %70SHR:% of load152Btuh23850Total capacity: Heating Equipment Design Conditions °F68.1Entering coil DB:Btuh44948Heat loss:°F-10Outdoor design DB: °F72.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Gas furnaceEquipment type: 59MN7B080C21--20Model:CarrierManufacturer: cfm1200Actual airflow: °F55Temp. rise:% of load121Btuh54600Output capacity: Meets all requirements of ACCA Manual S. Rig ht-Su ite® U niv er sal 20 22 22 .0.01 RSU1 5461 Form RPER 1 15 Mar 09 Residential Plans Examiner Review Form for HVAC System Design (Loads, Equipment, Ducts) Estes Park, CO Header Information Contractor:ATTACHEDREQUIRED ATTACHMENTSTri-City Heating and Air Conditioning, Inc. NoYesManual J1 Form (and supporting worksheets):Darin Ochsner Mechanical license:NoYesor MJ1AE Form* (and supporting worksheets): NoYesOEM performance data (heating, cooling, blower): Building plan #:10-10-22 NoYesManual D Friction Rate Worksheet: NoYesDuct distribution sketch: Home address (Street or Lot#, Block, Subdivision):2010 Cherokee Drive, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Front Door faces WestBuildingWinter Design Conditions North, East, West, South, Northeast, Northwest, Southeast, SouthwestOrientation:°F-10Outdoor temperature: °F72Indoor temperature: 3Number of bedrooms:Btuh44948Total heat loss: f t²3443Conditioned floor area: 4Number of occupants:Summer Design Conditions °F84Outdoor temperature: Windows°F75Indoor temperature: ft12.0Eave overhang depth:% RH50gr/lb @-11Grains difference: Blinds, drapes, etc. noneInternal shade:Btuh17512Sensible heat gain: Btuh141Latent heat gain: 0Number of skylights:Btuh17653Total heat gain: HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Blower DataCooling Equipment Data 1200Heating cfm:Air Conditioner, Heat pump, etc.Split ACEquipment type:Furnace, Heat pump, Boiler, etc.Gas furnaceEquipment type: 1200Cooling cfm: Fan's rated external static pressure for design airflow in H2O1.00Static pressure:CarrierModel:CarrierModel: 59MN7B080C21--20 24VNA937A0030 Btuh23850Total cooling capacity:Heat pumps - capacity at winter design outdoor conditionsBtuh54600Heating output capacity: Btuh16695Sensible cooling capacity: Btuh7155Latent cooling capacity:Btuh0Aux. heating output capacity: HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Duct Materials Usedft0Longest supply duct:cfm1200Design airflow: Trunk duct:ft0Longest return duct:in H2O1.00Equipment design ESP: ft0Total effective length (TEL):in H2O-0.5Total device pressure losses: Sheet metalBranch duct:Friction R ate = ASP ÷ (T EL x 100)in/100ft0Friction rate:in H2O0.51Available static pressure (ASP): I declare the load calculation, equipment, equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature:Date: Reserved for County, Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist Job #: 2010 Cherokee Drive Performed by TC for: Friedman Residence 2010 Cherokee Drive Estes Park - Larimer County, CO Tri-City Heating and Air Conditioning, I... P.O. Box 271972 Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 tricityhvac@yahoo.com Scale: 1 : 104 Page 1 Ri gh t-S ui te® Uni versal 20 22 22.0.01 RSU15461 2022-Nov-21 17:31:41 ... - Tri-City - Larimer County.rup N Level 2 Kitchen Great Room Dining Powder Laundry Pantry Mud Master Bedroom WIC Master Bath Stair/Hall Garage 21 cfm 207 cfm 207 cfm 99 cfm 79 cfm 103 cfm 103 cfm 39 cfm 154 cfm 101 cfm 140 cfm 20 cfm Job #: 2010 Cherokee Drive Performed by TC for: Friedman Residence 2010 Cherokee Drive Estes Park - Larimer County, CO Tri-City Heating and Air Conditioning, I... P.O. Box 271972 Fort Collins, CO 80527-1972 Phone: 970-493-0126 Fax: 970-493-0152 tricityhvac@yahoo.com Scale: 1 : 104 Page 2 Ri gh t-S ui te® Uni versal 20 22 22.0.01 RSU15461 2022-Nov-21 17:31:42 ... - Tri-City - Larimer County.rup N Level 1 Mech/Stor Office Bedroom 2 Clo 2Bath 2 Bedroom 3 Bath 3 TV Room B Hall/Stair Furnace 15 cfm 67 cfm 1531 cfm 34 cfm 12 cfm 78 cfm 65 cfm 54 cfm Crawlspace 117 cfm