HomeMy WebLinkAboutPLANS 23-289 418 Pawnee Ln, patio roof 2023-06-086/18/2020 REVIEWED BY SAFEBUILT 06/28/2023 A 1 2 3 B C EXISTING PATIO 03 A-100 (E) WALL (E) WALL COORDINATE TREE IN FIELD PROPOSED ROOF ABOVE 21 ' - 9 1 / 2 " 20' - 0" A 1 SKYLIGHTS: VELUX FCM 4672, CURB MOUNTED ON 2X6. INSTALL PER MANUFACTURER RECOMMENDATIONS. MIN. 6" CLEAR BETWEEN SKYLIGHTS FOR FLASHING. CRICKET AROUND SKYLIGHT. (E) ROOF (E) ROOF 2 3 B C 03 A-100 (E) FASCIA (E) ROOF WELL MATCH (E) ROOF ASSEMBLY. INSTALL PER MANUFACTURER'S RECOMMENDATIONS GUTTER, MATCH (E), DRAIN NORTH COORDINATE TREE IN FIELD MI N . 2' - 0 " (E) ROOF FASCIA REFER TO STRUCTURAL DRAWINGS 12" MIN, PER MANUFACTURER ABC 12" 1" (E) PATIO (E) ROOF WELL ROOF: •METAL ROOF PER MANUFACTURER •EPDM ROOF ASSEMBLY PER MANUFACTURER •STRUCTURE: REFER TO STRUCTURAL DRAWINGS MI N . C L E A R A N C E 6' - 8 " A 1 2 3 B C (E) ROOF (E) ROOF (E) ROOF WELL COORDINATE TREE IN FIELD EXISTING PATIO BELOW 0 1 2 4 8 Project: Project Number: Clients: Scale: Drawing Description: Drawn by:Checked by: Sheet Number: Date: Not Engineered Documents: The drawings provided herein are not engineered documents. The Designer is not a licensed engineer and the engineering of the design shall be performed by a licensed professional who shall affix their seal on the appropriate documents prepared by them. The Client and the Client's consultants shall be required to defend, indemnify and hold harmless the Designer for claims, damages, losses, and expenses ("Damages") to the extent such Damages arise out of the errors, omissions, negligence, misconduct, or failure to properly discharge their contractual duties to the Client. In addition, the contracts between the Client and the Client's Consultants shall require the Client's Consultants to coordinate their drawings and other instruments of service with those of the Architect for any potential conflict. The Architect shall have no responsibility for the components of the Project designed by the Client's Consultants. Review by the Architect of the Client's Consultants drawings and other instruments of service is solely for consistency with the Architect's design intent of the Work. The Architect shall be entitled to rely on the technical sufficiency and timely delivery of documents and services furnished by the Client's Consultants, as well as on the computations performed by the Client's Consultants in connection with such documents and services, and shall not be required to review or verify those computations or designs for compliance with applicable laws, statutes, ordinances, building codes and rules and regulations. The Client shall defend, indemnify and hold harmless the Architect from and against claims, damages, losses, and expenses, including, but not limited to, attorney's fees arising out of the services performed by the Client's Consultants. 1/4" = 1'-0" APN: 3401243003 418 Pawnee Lane, Estes Park, CO 80517 Suzanne & Gregg Jurgens PAWNEE ROOF ADDITION A-100 12/28/2022 SCALE:1/4" = 1'-0" PATIO FLOOR PLAN 01 SCALE: 1/4" = 1'-0" PROPOSED ROOF ADDITION 04 SCALE: 1/4" = 1'-0" PROPOSED SECTION 03 Rev.Issue Date 418 PAWNEE LANE, ESTES PARK, CO 80517 Homeowner: Suzanne and Gregg Jurgens December 28, 2022 Scope of Work: Exterior roof addition to single-family home APN: 3401243003 LOT: LOT 3, 3295 APACHE ACRES SUBDIVISION, EP (2000066548) Zone: E-1 DRAWINGS NOT FOR CONSTRUCTION SCALE: 1/4" = 1'-0" EXISTING ROOF PLAN 02RAFTREVIEWED BY SAFEBUILT 06/28/2023 DETAIL A SCALE 1/2" = 1'-0" DETAIL B SCALE 1/2" = 1'-0" 300 E. ELKHORN, ESTES PARK, CO, 80517 504-940-8278 REV DATE COMMENT SHEET NUMBER: PROJECT NUMBER: ALL INFORMATION ON THESE DRAWINGS ARE THE INTELLECTUAL PROPERTY OF SKYPOND ENGINEERING AND MAY NOT BE REUSED OR DISTRIBUTED WITHOUT THE COMPANY'S CONSENT 55436 M A T THE W K HAC H A T U R IAN COL O R A DO LIC E NS E D P R O F E SSIONAL E N GINEER 2/20/23 S1 2220 A 10/26/22 FOR REVIEW 0 11/15/22 PERMIT SET 1 11/17/22 REVISED 2 2/20/23 REVISED 3 1/2" X 12" GLULAM RAFTERS 1" 12" C A PLATELINE C A 1 3 SITE & LOAD INFORMATION 1. CODE: 2015 INTERNATIONAL RESIDENTIAL CODE 2. SITE ELEVATION: 7,800 FT. 3. FROST DEPTH: 30IN 4. EXPOSURE CATEGORY: B 5. GROUND SNOW LOAD: 68 PSF 6. ULTIMATE WIND SPEED: 175 MPH 7. ALLOWABLE BEARING PRESSURE: 2,500 PSF. 8. DEAD LOAD: 20 PSF GENERAL 1. ENGINEERING SCOPE IS TO PROVIDE ROOF DESIGN WITH CONNECTIONS AND FOOTINGS. 2. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE. 3. ALL FIELD MEASUREMENTS TO BE VERIFIED BY CONTRACTOR BEFORE CONSTRUCTION. 4. IT IS THE OWNER'S RESPONSIBILITY TO CONFIRM THE ALLOWABLE BEARING PRESSURE, WHICH HAS NOT BEEN BASED ON A GEOTECHNICAL STUDY, AND IS ASSUMED AT 2,500 PSF. 5. DETAIL DRAWINGS SUPERCEDE ANY VISUAL APPEARANCE IN THE MAIN SECTION AND PLAN VIEWS. REFERENCE THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN. 6. ONLY THE FINAL REVISION OF THIS DRAWING SHALL BE USED FOR CONSTRUCTION. IT IS THE BUILDERS RESPONSIBILITY TO ENSURE THEY HAVE THE FINAL REVISION. CONCRETE 1. ALL CONCRETE DESIGN IS BASED ON ACI318 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 2. ALL STRUCTURAL CONCRETE SHALL HAVE MINIMUM 28-DAY COMPRESSIVE STRENGTHS AT 3,500 PSI. 3. CONCRETE SHALL BE PROPORTIONED USING TYPE I/II CEMENT. CONCRETE SUSCEPTIBLE TO FREEZING SHALL BE FORMULATED FOR MAXIMUM FROST RESISTANCE IN ACCORDANCE WITH ACI. 4. SLABS ON GRADE SHALL BE PLACED ON APPROVED MATERIAL PER GEOTECHNICAL ENGINEER. 5. CONTRACTOR SHALL NOTIFY ENGINEER OF COLD AND CONSTRUCTION JOINTS PRIOR TO CONCRETE FORMING. 6. CONCRETE FORMING PROCEDURES SHALL BE USED IN ACCORDANCE WITH ACI. 7. ALL EXPOSED EDGES AND CORNERS SHALL BE CHAMFERED MIN. 3/4". 8. ALL POST BASES SHALL BE ABA SIMPSON STRONG TIE AND INSTALLED PER MANUFACTURER INSTRUCTIONS, U.N.O. STRUCTURAL WOOD FRAMING: 1. ANY NON-DETAILED CONNECTIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2015. CONTACT ENGINEER FOR ANY CLARIFICATIONS. 2. ALL 2" LUMBER, FLOOR JOISTS, RAFTERS, SOLID TIMBER BEAMS, AND POSTS SHALL BE DOUGLAS FIR-LARCH NO. 2 AND BETTER, UNLESS NOTED OTHERWISE. 3. TOP AND BOTTOM PLATES FOR WALL CONSTRUCTION SHALL BE HEM FIR NO.2 OR BETTER. 4. ALL GLULAMS SHALL BE 28F-2.1E SP. 5. ROOF SHEATHING SHALL BE 1 1/2" T&G. 6. ALL SHEATHING SHALL BE INSTALLED W/ 8D NAILS @ 3" ALONG EDGES & 6" IN FIELD. 7. ALL LUMBER SHALL BE 19% MAXIMUM MOISTURE CONTENT. 8. PROVIDE SIMPSON ANCHORS AT SUPPORTS FOR ROOF RAFTERS AND TRUSSES. 9. PROVIDE BLOCKING AT BEARING LOCATIONS OF JOISTS, RAFTERS, & BUILT UP COLUMNS. 10. SIMPSON STRONG TIE HANGERS AND CONNECTORS SHALL BE USED FOR ALL CONNECTIONS, U.N.O. 11. LEAD HOLES FOR LAG BOLTS AND SCREWS SHALL BE DRILLED IN ACCORDANCE WITH AITC TIMBER CONSTRUCTION MANUAL. PA W N E E R O O F A D D I T I O N 41 8 P A W N E E L A N E , E S T E S P A R K , C O , 8 0 5 1 7 ROOF SIDE VIEW SCALE: 1/4" = 1' - 0" 6X6 POST 21'-9" 20'-0" 20'-0" 7'-2" 5 1/2” X 16” GLULAM BEAM 2'-6" FROST DEPTH 2'-4" FOOTING DETAIL SCALE: 1/2" = 1' - 0" ROOF TOP VIEW SCALE: 1/8" = 1' - 0" (3) 2X6 STUD PACK IN EXISTING WALL 6X6 POST 2'-0"EXISTING STRUCTURE TWO MATS OF (3) #4 GLULAM BEAM GLULAM BEAM 1'-3" CS14 COILED STRAP (EA. SIDE) STUD PACK ENSURE BLOCKING THROUGHOUT WALL TO SUPPORT NEW RAFTERS (TOE NAIL TO WALL TOP PL) SHEATHING NOT SHOWN FOR CLARITY MECHANICALLY SEAMED METAL ROOF SIMPSON 2.5A HURRICANE TIES (1EA. ON EXTERIOR RAFTERS & 2EA. ON INTERIOR RAFTERS) APB SIMPSON POST BASE APL SIMPSON L-STRAP TIE (EA. SIDE) BLOCKING BETWEEN RAFTERS SIMPSON 2.5A HURRICANE TIE SHEATHING REMOVE EXTENDED ROOF AS REQUIRED 4'-7" 4'-7" 4'-7" 4'-7" 3'- 1/2" 2X8 RAFTER W/ LU28 SIMPSON HANGERS (TYP.) 6'-10"6'-10" 2 2 2 SAFEbuilt APPROVED Subject to inspection and compliance to all relevant Adopted Building and Municipal codes. Changes in Plans MUST be approved. D.GRAHAM 06/28/2023 I-CODES 2015 23-ep-00289 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION LEAVE OPEN FOR lNSPECTION