HomeMy WebLinkAboutPERMIT 580 Audubon St Single Family Dwelling 1995-04-04TOWN OF ESTES PARK
Building Department
2:14 ^,W.,014
tr.
IT
N2
Date
BUILDING ADDRESS
Legal Description
04a 0„,:11/,615,75„,
0
N
E
NAME
MAILING ADDRESS
PHONE NUMBER
NAME
ADDRESS
E
• PHONE NUMBER
F-
E.
P C
L 0
U N
MT
B. IL
ADDRESS
TOWN LICENSE NO,
NAME
ADDRESS
TOWN LICENSE NO.
122
401';22
Valuation
371
Building Permit r„:"
& Plan Review
Other
Certificate of Occupancy
P/
Total
c.0
/
atai -7;;Ir
222 S,2'2§572
)
TOWN LICENSE NO
c) Ardimesigner/Engin.
u
Type of Construction I FR, I FR, II 1-Hr„
N, 11 1-Hr„, lI N, IV HT,
V 1-Hr.,
i_Address 7.7)222),,,,„,
Occupancy Group A, B, E, F, H, 1, M, R S, U
Phone Number
ZONING INFORMATION
ateeRt:?!../4e'L'
1522."
Zoning District
Front Yard Setback
Side Yard Setback
Rear Yard Setback
Div 1, 2, 2.1, 4, 5, 6, 7
BUREAU OF THE CENSUS ITEM ,y)4,
„p11
CLASS OF WORK
FLOOD PLAIN CHECK
New
Alteration
Addition
Demolish
Repair
Remove
use of Building
Floor Area
Size of Building
Maximum Occupancy
Number of Baths
Number of Floors4,'":„,.
Ful
No. Bedrooms 75
ricl Garage
Height 2_3 f,
Number of Families
Size of Lots /
*:5
Number of Buildings
Now on Lot
Approved
Disapproved
Comments
Flood Zone:
ro'
I hereby acknowledge that I have read this application and state that
the above.,,ja erirrect and agree to comply with all Town Ordinances and
State LgVis, regulatingbuilding copsfiiii n and zoning.
! „a.; , , ,
, 4
/ Permae-
trr''-11 2';"--
.., . -
By
Use of Buildings
Now on Lot
Certificate of Occupancy Number /6,
Building Inspector
By
The Building Department will make every (Mott to prevent errors in
your application and pernat, but cannot be responsible for your failure
to comply with all Building, Zoning and other applicable codes.
T N OF ESTES PARK
BUILDING DEPARTMENT
NO.
CERTIFICATE OF OCCUPANCY
This is to certify that the
Estes Park, Colorado 80517
ERECTED ON Lot No,
Addition
Street
Block No.
Mailing Address'
Architect , Contractor
Building Permit No,
Zoning Occ. Gr.
has been inspected and the following occupancy thereof is hereby
authorized:
Occupancies
Basement
1st Floor
2nd, Floor
Roof
Date
Maximum Allowable
Floor Loads, Lbs.
Per Sq. Ft.
Building Inspector
P. C). Box 1200 Telephone (303) 5 -5331
UILSING PE T 'PLICATISN
and
OUTING SLIP
OWNER•!;:'‘.)„ fr
PHONE yet 7- 7(7)(73(6DATE
Mailing. Address ro (,„. t1 s
UILDING ADDRESS/JOB SITE
LOT 1 BLOCK SUB rift. LOT SIZE 0.
GENERAL CONTRACTOR ,(4); tr( ,/1",/t cte kr,,
PHONE 7,, /-- ecr)EL)
Mailing Address 0CC , e.. -; (04 ( (0,„, ,c#
//
) '
Mailing Address P c;?-) ELECTRICAL CONTRACTOR ( (.7
co)cc
Pa k
PLUMBER (-)eCT (T) 1/G0-4. OCC 1Z-1
Mailing Address -1')C.1.) re
DESIGNER 12)elut / 4:( , e v"( kelt PHONE-77 {- "EOCC. #
TYPE OF HEAT: Gas L Eietric1..„--/ Other JOB VALUATION
DESCRIPTION OF WORK
I. PUBLIC WORKS DEPARTMENT
ENGINEERING
Remarks MA
Approved Date
WATER DEPT.
Remarks
FINANCE - Water Fees Paid - Yes ( ,1) No
'f 5- Ku
17 75
( )
Approved DATE
. LIGHT & POWER DEPARTMENT
Remarks "."Pe'721`1 A,14?;,- 04:f
i.Jjj 3 .
Approved 4'2; _ 0-00, Date 01(00,779.0.-
3 COMMUNITY DEVELOPMENT DEPT.
Remarks '4/6' wibe: 4/5 AM1r 1/14=4-A, 44sr
Approved /14 Date 37/61i
. URBAN RENEWAL AUTHORITY
Remark
Approved Date
5. COUNTY HEALTH DEPARTMENT
Remarks
Approved
Date
6. UPPER THOMPSON arxESTEISMPARICSANITATION DISTRICT
Remarks & permit fees all paid this date 4/A/95
Approved .;;; Date
7. TOWN CLERK
Remarks
Approved Date
Owner
s
WATER DEPARTMENT
CONNECT FEE
7/1
Address 6 0.73
cf-A.
Location
Units
Fixtures
Date of Service _
MUST BE IN SERVICE
Z-/C(•/
Plumbers BY _
2068
Received of
Sum ot $
FOR:
Tap Fee
Water Rights
TappngJv1atenaIs
V Meter-Read/Out
Filing Fee
Other
Date
3d-Pize)
TOWN OF ESTES PARK
VALUATION SCHEDULE
BASEMENT UNFINISHED . .
BASEMENT F I N ISHED
DWELLINGS:
AVERAGE V MASONRY . . • 4 SQ. FT
AVERAGE V WOOD FRAME . zp.,12SC . FT. @ 51=
GARAGE:
WOOD FRAME
MASONRY.
O 0 6 • 0 6
0 6
OPEN CARPORTS T
PATIOS OR PORCHES OPEN
PATIOS OR PORCHES ROOFED.
4 6 X • y
6 RV • 0
0. 0
4 4
6 0 • 6 6
OTHER Fe4C-1-`)(< F (kFpL E
• 'IF 4'7' pc. cr
OTHER 1F., Pt/L:7E
Ln
E /7P
C. 0.
Ti L
SQ. FT. @ usa.
SQ. FT. (a /Li. '77=
SQ. FT. 5.9e=
SQ. FT. @ 7.3Z=
sq. FT. @
SQ. FT. @ q0c7=
SQ. FT. @ 4).77.
Boa
# 7
,r7 I -too
TOTAL VALUE_
2..„. 7A. 7 41
:2_2„, )
RESIDENTIAL PLAN CORRETION LIST
ASSUMPTIONS
Design Information
Frost line 30 inches below grade; wind speed 90 MPH; 40 lb.
live load on roofs; 60 lb. live load on balconies; 40 lb. live
load for residential floor systems.
Approved Numbers or Addresses
Be provided for all new buildings in such a position as to be
plainly visible and legible from the street or road fronting
the property. Section 513 UBC.
JOB ADDRESS
General %,,,,” .,, ,0 //• 272//::
E i. Submit fully dimensioned plot plan. ,57,44eve) , _7,
7\2. Give name of firm/person responsible for plans.
Foundations
E
3. Provide footing with a minimum depth below finish natural
grade of 30 inches. Table No. 29-A UBC.
4. Specify garage foundations to meet requirements as for
a one-story building.
Bolt foundation plates and sills to the foundation with
bolts spaced not more 4'0" apart. Embed bolts at least
7" in concrete or reinforced masonry (use 1/2" x 10" sill
bolts - Estes Park is in a 90 MPH wind speed area).
Section 2907 (F) UBC.
Plates, sills and sleepers which rest on concrete or
masonry shall be treated wood or No. 2 foundation redwood
or better. Section 2516 (c) UBC.
7. The minimum thickness of concrete floor slabs supported
directly on the ground shall not be less than, 3 1/2
inches. Section 2623 UBC.
Damp proof foundation walls enclosing a basement below
finished grade. Section 1708 (d) UBC.
FRAMING
Provide wood species and grade for all lumber, plywood,
particle board, glued -laminated timber, and provide
manufactured joist -truss information. Section 2505 UBC.
10. Provide a structural section which shows typical framing
conditions for this project. Scale 3/8" = 1'0" Section
302 UBC. „7,4,;()" r-7/7,72:2
D 11. Roof rafters over -spanned. (Live load 40 lbs per sq. ft.
in Estes Park).
12. Specify roof covering materials and application in areas
subject to wind -driven snow or ice build up. Chapter 31
UBC.
. Provide rafter ties where ceiling joists and rafters are
not parallel. Section 2517 (g) UBC.
14. Show double top plates at top of stud walls. Section
2527 (g) UBC.
T] 15. Provide 22" x 30" (or 30" x 30" for mechanical equipment)
minimum access to attic. Section 3205 (a) UBC; Section
708 UMC.
416. Specify ceiling joist spans to comply with Table No. 25-
U-J-6 UBC.
17. Provide size of header for openings over 4'0" wide. A
header table may be used for this purpose.
2:18. Specify floor joist spans to conform with Table No. 25-
U-J-1 UBC-
019. Provide double joist under parallel bearing partitions.
Section 2517 (d) UBC.
20. Provide 18" x 24" (or 30"x 30" for mechanical equipment)
under floor access opening. Section 2516-C UBC; Section
709 UMC.
21. Provide under -floor clearance as specified in Section
2516 (c) UBC.
22. Provide under -floor ventilation equal to one square foot
for each 150 square feet of under —floor area. Operable
louvers may be used. Section 2516 (c) UBC.
2
LIFE S
23. Stairways: Maximum rise 8 inches and a 9 inch minimum
run. Minimum headroom 6 feet 8 inches. Width 36 inches.
Section 3306 UBC.
24. The top of handrails shall be placed not less than 34
inches, or more than 38 inches above the nosing. Ends
shall be returned or shall terminate in newel post or
safety terminals. Section 3306 (i) UBC.
E 25. Basements in dwellings and every sleeping room below the
fourth story shall have at least one operable window or
door approved for emergency escape or rescue. Section
1204 UBC.
26. Smoke detectors shall receive their primary power from
the building wiring and shall be equipped with battery
backup in new construction. Section 1210 UBC.
X27. A smoke detector shall be installed in each sleeping
room, corridor, or area living access. A detector shall
be installed on each story and in the basement. Section
1210 UBC.
MECHANICAL
28. Where mechanical ventilating system in bathrooms is used,
provide five air changes per hour directly to the
outside. The point of discharge of exhaust air shall be
at least 3 feet from any openings into the building.
Section 1205 UBC.
029. Provide every dwelling with approved heating facilities.
Section 1212 UBC.
I:30. Show water heater location. Section 1309 UBC.
E131. Show how water heater and furnace will be provided with
outside combustion air. Chapter 6 UMC.
32. Provide complete details, make model and listing of
fireplaces.
GARAGE
E] 33. Do not show openings from garages directly into a room
used for sleeping. Section 1104 UBC.
fl 34. On the garage side, install materials approved for one -
hour fire resistive, construction. Specify self -closing,
tight -fitting solid wood door 1 3/8 inches in thickness,
or a self -closing, tight -fitting door having a fire
protection rating of not less than 20 minutes. Section
503 (d) UBC.
ADDITIONAL CO
4
vcr;;0>L7sev4 4741"0:1 0-> "..>rzi s`a..1-7-Z - - .10-7
Q.;
<2)
Q
71
L� f,
kL1 `!
(1
1I
0*P 'GKI`d j _40-1
1,; -3-21Hg IC;
T
,
t
G