HomeMy WebLinkAboutLETTER Noth Wall Header Replacement 460 Valley Rd 2024-02-19itt tt* lt`ttt: LAND SURVEYS SUBDIVISIONS DEVELOPMENT PLANNING IMPROVEMENT PLATS STRUCTURAL ENGINEERING SANITARY ENGINEERING MUNICIPAL ENGINEERING D.ATE, TO: FROM: /17 VAN HORN ENGINEERING AND SURVEYING February 19, 2024 Building Departrn.ent Frank 1 Roberts, P.E, RE: 424-EP-00003 North Wall Header Replacement 4(0 Valley Road. Estes -Park, CO 80517 Building Code Information: 2021 IRC IBC Ground snow load 67.1 psi (7,710' elev.) Roof snow load 51,7 psf Wind speed = 175 mph Exp. C Seismic Design Category 13 po e • 39"508 fizzip6, "; /10/2024 The home remodel project encountered an existing composite header along the north edge of the main cabin over an opening of approximately 11wide in an interior wall (attached covered area adjacent to the wall in question). The existing header is comprised of 2-2xI2 sawn lumber with a timber beam below the header. The timber is planned to bc removed and the existing header size was verified to be inadequate for current design loads with removal ofthe timber. The header should be upgraded to (2) 13/4"x 11 7/8" LVLs with (2) 2x4 jack studs each end. Lumber shall be Hem Fir 42 or better and LVL material shall be 2,0E or better, If there are any questions, please do not hesitate to call me at 970-586-9388. t 043 Fish Creek Road • Estes Park, Colorado 8051'7 • 970-586-9388 • E-mail: info ydvanhornengineering.com