Loading...
HomeMy WebLinkAboutDOCUMENT Window Specs 2441 Arapaho Rd 2024-05-18Order Summary Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 JOB PHOTOS Image 1 Image 2 Image 3 Image 4 Image 5 Image 6 Image 7 Image 8 Image 9 03/22/24 Page 6 / 30 101 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 101 Primary Bathroom 55-3/4" W 48-5/8" H Window, Casement - Double Window: Acclaim™ Casement Double, Vented, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze, Wide Opening Hinge Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 9 / 30 102 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 102 Primary Bedroom 35-3/4" W 60-1/2" H Window, Casement - Single Window: Acclaim™ Casement Single, Right, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 11 / 30 103 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 103 Primary Bedroom 35-3/4" W 60-1/2" H Window, Casement - Single Window: Acclaim™ Casement Single, Left, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 13 / 30 104 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 104 Primary Bedroom N 35-3/4" W 60-1/2" H Window, Casement - Single Window: Acclaim™ Casement Single, Right, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 15 / 30 105 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 105 Guest Room 71-3/4" W 60-1/2" H Window, Casement - Double Window: Acclaim™ Casement Double, Vented, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 17 / 30 106 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 106 Guest Room N 35-3/4" W 60-1/2" H Window, Casement - Single Window: Acclaim™ Casement Single, Right, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 19 / 30 107 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 107 Office 35-3/4" W 60-1/2" H Window, Casement - Single Window: Acclaim™ Casement Single, Left, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, High Altitude Breather Tubes Hardware: Distressed Bronze, Estate Finish Extra Lock Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 21 / 30 001 Michael & Barbara Keilty 2441 Arapaho Rd Estes Park, CO 80517 C: (317)701-0823 dba: RENEWAL BY ANDERSEN OF COLORADO Legal Name: Window Warmth LLC | License # CO244783 1401 West Bayaud Ave, Unit 7 | Denver, CO 80223 Phone: 720-829-4330 | Fax: 303-217-4099 | (null) Measure Tech: Sean MacDonnell, (720)939-1531 001 basement bedroom 71-3/4" W 42-3/8" H Window, Casement - Double Window: Acclaim™ Casement Double, Vented, Base Frame, Exterior Red Rock, Interior Pine Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, Tempered Glass, High Altitude Breather Tubes Hardware: Distressed Bronze, Wide Opening Hinge Screen: Fiberglass, Full Screen Grille Style: No Grille Misc: *R&C - Pine (Without Sill) Construction: Interior Returns and Casing (1) Material: A1 - Foam Insulation (0.3), A2 - Ice/Water shield (0.1), I1 - Caulk - Red Rock (1.5), I2 - Coil - Red Rock (0.1), G1 - 1x4 - 8' - clear pine- CO Lumber (2) UNIT NOTESUNIT NOTES UNIT CONSTRUCTION Interior Returns and Casing 1 UNIT MATERIALS 2 COIL/ CAULK AND WAREHOUS E ITEMS A1 - Foam Insulation 0.3 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS A2 - Ice/Water shield 0.1 1s 2 COIL/ CAULK AND WAREHOUS E ITEMS I1 - Caulk - Red Rock 1.5 tubes 2 COIL/ CAULK AND WAREHOUS E ITEMS I2 - Coil - Red Rock 0.1 rolls 4 INTERIOR PINE TRIM G1 - 1x4 - 8' - clear pine- CO Lumber 2 x 8ft 03/22/24 Page 23 / 30 Renewal by Andersen Minimum Installation Standards (revised 10/14) 1 Renewal by Andersen Minimum Installation Standards There are many types of openings into which Renewal by Andersen® windows can be installed into. Each type of opening and each individual opening may have any one or more of many varying existing conditions. Understanding that the existing conditions will determine many of the specific installation details and that it is up to the installer to comply with local requirements and best practices, it is expected that each Renewal by Andersen window will be installed to meet the following minimum requirements: 1. Anchoring a. Through the Jamb: - Install one #8 pan head screw at each pre-drilled installation hole. - Jamb to be supported with shim at each installation screw. - Minimum screw embedment into structural material is 1”. - No fasteners to be installed through sills (except as indicated for picture windows and casement/awning window units greater than 40”). - If anchoring into pressure treated lumber or fire retardant treated lumber, screws must be of approved corrosion resistant material. b. Through Nailing Flange: - Flange method applies to Renewal by Andersen product utilizing accessory nailing flange (Renewal part no. 7500806). Nailing flange can be used on Renewal by Andersen full frame products, Base Frame and Extension Jamb frames only. - Flanges are to be full width and height of window and applied full perimeter of window. - Prior to installation, the flanges are to be joined and sealed at each corner with nailing fin corner seal (Renewal by Andersen part no. 7500718). - When anchoring window to wall, install one galvanized roofing nail through each pre-punched hole in flange. - Each nail to penetrate structural material (solid wood) a minimum depth of 1”. - Upon completion of anchorage, the nailing flanges are to be sealed to window frame with a continuous 3/8” fillet bead of sealant, full perimeter of window frame. c. With Jamb Clips: - Jamb clip method applies to Renewal by Andersen product utilizing jamb clips (Renewal by Andersen part no. 7500782 for Full Frame Windows and 9032314 for current casement, awning and gliding windows Base frame or Extension jamb frame). Jamb clips can be used on Renewal by Andersen full frame, Base frame or Extension jamb frames only. Renewal by Andersen Minimum Installation Standards (revised 10/14) 2 - Jamb clips should be applied around all four (4) sides of window and placed 6” from each corner, then spaced no more than 18” apart. - Jamb clips should be positioned at an angle 90 degrees to jamb when anchored. - Jamb clips should be secured to jamb of window unit with full engagement into locking features (profiles) on jamb. Jamb clip attachment to jamb is to also include placement of a #8 screw through pre-punched hole in clip, anchoring to wall of window jamb. - Each jamb clip should be anchored to opening with a minimum of two (2) 8d nails or #8 screws with at least 1” penetration into structural material. 2. Joining a. To be done in accordance with Renewal Product Installation Manual. b. Each end of join should be anchored to opening with a minimum of four (4) #8 screws, each with a minimum of 1” penetration into structural material: - Full Frame Steel Joins – Anchor through flanges of end brackets at both ends of joint (Renewal by Andersen part no. 7500651). - Full Frame Wood Joins – Anchor both ends of joint to rough opening with two (2) jamb clips on each end (Renewal by Andersen part no. 7500782), one on each side of joint. - Insert Joins – Anchor though flanges of mull anchor (Renewal by Andersen part no. 7501601). c. Note: Any mull anchor fasteners used on the drainage surface of a sill or sill flashing must be corrosion resistant material and sealed to help prevent water entry into wall. 3. Shimming a. Renewal by Andersen windows are to be set so that sill is supported in a flat position. Flat position can be achieved by: 1. Full support of existing opening. 2. Shimming - If shims are required under sill to achieve a flat condition, support is required under end of sill (directly below side jamb). Additional shims under sill should be spaced no more than 12” apart. Also place shims on each side of a mulled unit under each side jamb and under the meeting stiles of a gliding window unit. b. Shims used under sill must be non-compressible, flat, plastic shims.(such as Renewal by Andersen 7500653-PKG 1/16” and 7501047-PKG 1/32”) c. Shims are required between side jambs and rough opening at each pre- drilled installation hole. Renewal by Andersen Minimum Installation Standards (revised 10/14) 3 d. Shims are to position and support sills and jambs straight to within 1/16” overall. e. Shims are to position and support window frames square to within 1/8” as measured diagonally. f. Shims are not to be installed above head jambs. 4. Water Management a. INSERT METHOD: (Units being installed into pre-existing window frames are to be installed by the “insert method”.) When installing a new window into the frame of an existing window, the entire perimeter of insert window must be sealed to the existing window frame. - Existing wall flashings must remain in place and left intact and undamaged by installation procedure. - Primary sealant joint must be a continuous, durable joint between insert window frame and existing window frame. * An exception is over-fit / flush fin type installations in which the new window flange is sealed to face of an existing metal window frame. In an over-fit installation, the sealant joints between sill flange and existing window frame must be discontinuous to facilitate drainage. There should be two (2) 1”-2” voids in the primary and secondary seals, both near weep holes of pre-existing frame. Primary seal is a properly configured and tooled butt joint, fillet joint or lap joint bead as detailed in ASTM-E2112. Joint-type depends on geometry between new frame and existing frame. Primary seal is to occur between the new window frame and existing window frame. Sealant joints between trim components and siding are not considered primary seals. b. Complete Replacement Method: Units being installed into rough openings (in which the pre-existing window frame has been removed from the wall) are to be installed using the “Complete Replacement method”. When installing a new window into a rough opening in which the pre existing window frame was completely removed, the new window is to be integrated with the existing building envelope. Renewal by Andersen Minimum Installation Standards (revised 10/14) 4 - Sills must be flashed prior to placement of window. Sill flashing must be a flexible membrane or preformed vinyl. A metal pan that extends full width of wall provides a thermal bridge and should be avoided in cold climates. - Sill pans are to include side dams and back dams. Back dams may interfere with interior trim detail. In these cases, a continuous bead of sealant with closed cell foam backer rod or closed cell aerosol foam sealant will function as a back dam. - Mull anchors, and fasteners that penetrate sill flashing must be sealed with sealant. - Sill flashing will shed water to either: 1. Weather Resistant Barrier (WRB) consisting of properly lapped house-wrap or felt paper. 2. Exterior surface of wall (siding). - If a WRB exists behind the exterior cladding (siding/stucco/brick), the new window should be sealed/integrated to this membrane using flexible adhesive- backed (butyl) flashing tape at least 4” wide and lapped in proper shingle fashion. This may require removal or cutting back of exterior cladding to gain access to WRB. - If a WRB is not present behind the exterior cladding or if it is not possible to access the WRB, or if there are any indications that the WRB is not draining correctly, the new window should be flashed so that water is shed to exterior surface of wall cladding. - Head Flashing:  Reuse existing drip cap and/or rigid head flashing if one is present and functioning properly.  If no drip cap or rigid head flashing exists or if the existing one is in poor condition, install a new one.  Head flashings (drip caps) must be a corrosion resistant metal such as galvanized steel, stainless steel, copper or aluminum.  Head flashings must have a vertical leg of at least 1½” in height extending up under the WRB.  Head flashing must have a vertical front leg of at least ½” that extends down over the front of the window frame or trim. This front leg should occur at least 3/16” out from face of frame or trim to facilitate drainage away from window.  If installing a new rigid head flashing, the ends should be cut and folded down over the ends of window frame, head trim or wood drip cap. Renewal by Andersen Minimum Installation Standards (revised 10/14) 5  Head flashings must be full length across width of window and continuous across join.  Under side of head flashing must be sealed to top of window frame.  The joint occurring between top side of head flashing and the siding above the window is to be left open. This joint is unsealed to facilitate proper drainage. Barrier Wall Integration: If the wall is not a membrane drainage wall, but rather an outer surface barrier type wall (like a concrete foundation wall), new window is to be sealed directly to wall with a continuous sealant joint around perimeter of window. 5. Insulating and Air Sealing a. The space between the new window frame and the opening, behind primary seal must be filled and/or sealed to help prevent conduction and air infiltration around perimeter of unit. b. Insulation and air sealing material must be glass fiber or closed cell aerosol foam sealant. If closed cell foam is used, it must be low expansion, low pressure type intended specifically for doors and windows. c. If gap between window frame and opening is too narrow for the placement of closed cell foam or glass fiber, seal the interior side of gap with caulk sealant. d. Application of insulation must not distort jambs or sill. Jambs and sill must remain straight to within 1/16”. e. When sill pans are used, space under window must not be filled to the extent that drainage will be prevented. Fill only the interior edge of this gap with sealant or insulating foam to create a back dam. 6. Exterior Trim a. Fibrex® exterior trim used with insert units must be sealed to existing window casing with 3/8” fillet bead of sealant. Bottom end of Fibrex material trim should be left unsealed for drainage. b. Dimensional trim such as wood, PVC, etc. can be applied in watershed fashion over the drainage plane as if a siding material. Top edge of trim should be integrated with siding by use of a rigid head flashing. c. Coil stock trim should be applied in water-shed fashion starting at sill working up sides, then finishing with head flashing and drip cap. Head flashing to tuck under existing WRB, if present. d. There should be no reverse laps with coil stock trim. Renewal by Andersen Minimum Installation Standards (revised 10/14) 6 e. All coil stock trim profiles are to be fully supported by existing wood trim or with new wood backing material. f. Trim components that interface with siding material should be sealed to siding. Note: These standards represent minimum requirements for the matters addressed above. Renewal by Andersen Corporation prepared these standards based on AAMA published standards and other industry sources. These standards do not replace the more complete information included in the Renewal by Andersen Installation Manual. These standards do not address all potentially applicable local codes or other requirements. It is always the responsibility of the installer to make certain that any installation complies with all local requirements and best installation practices.