HomeMy WebLinkAboutPLANS Deck 1059 Lexington Ln 2024-05-06PERMIT #24-EP-00134
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 5/6/2024 - BY PBland
PERMIT #24-EP-00134
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 5/6/2024 - BY PBland
All work shall be performed by Licensed
Contractors OR work shall be performed
by the homeowner residing in the dwelling
PLANS AND CONSTRUCTION SHALL
MEET THE 2021 IRC AND ALL
APPLICABLE MUNICIPAL CODES &
ORDINANCES
PERMIT #24-EP-00134
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 5/6/2024 - BY PBland
Exterior Guards - Per R507.10
13. Guardrail required for over 30"
14. Guardrail openings = No openings that allow passage of a 4" sphere.
15. Guardrail shall be a min. 36" in height
16. Guardrail to meet 200lb. uniform live load
PERMIT #24-EP-00134
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 5/6/2024 - BY PBland
Ledger board
OPEN HOLE INSPECTION REQUIRED FOR
DEPTH & SIZE OF CAISSONS/PIERS -
BEFORE CONCRETE IS POURED
CAISSONS/FOOTERS SHALL BE
SUPPORTED ON UNDISTURBED NATURAL
SOILS OR COMPACTED ENGINEERED FILL -
PER 403.1
In accordance with Manufacturers installation requirementsPlastic Composite
center concrete
column shall be
min. 16" dia.
per Table R507.3.1
Lateral restraint shall be provided
by manufactured connectors -
see handout
Connectors & fasteners in contact with
preservative-treated wood shall be of hot dipped,
zinc coated galvanized steel, stainless steel, silicone
bronze or copper
See table R507.2.3 for Deck Fastener and connector
specifications - Unless noted otherwise on this drawing.
Min. 2x8 Ledger -
pressure-preservative-treated
No. 2 grade or better
Wood materials used to be No. 2 grade species or
better & Preservative-treated or approved Naturally
durable wood in accordance with Section R317 &
AWPA U1 - Unless noted otherwise on this drawing
APPROVED by SAFEbuilt;
2021 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
05/06/2024
ALL BEAM/JOIST SPLICES MUST
OCCUR OVER POST/SUPPORT
WITH 1 1/2" BEARING
REMOVE EXTERIOR SIDING OR VENEER
BEFORE ATTACHING LEDGER
ROUGH INSPECTION REQUIRED PRIOR
TO INSTALLATION OF DECK BOARDS
PERMIT #24-EP-00134
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 5/6/2024 - BY PBland
SITE PLAN REVIEWED
FOR BUILDING
COMPLIANCE
NO PORTION OF ANY BUILDING OR
STRUCTURE SHALL ENCROACH INTO OR
OVER AN EASEMENT LINES