HomeMy WebLinkAboutPLANS Remodel 2049 Uplands Cir 2023-12-05DN
UP
3 9/16"
4'-11"
4 7/16"
9 1/16"2'3'-3 1/16"4"3'5 7/8"5'-5"6"5'-5"5 1/2"2'-6 3/16"2'1'-0 9/16"
7'-9 3/4"4'-11"6 1/2"4'-11"2'-3 3/4"1'-9 1/8"12'-1"7 7/8"10 1/16"3'1'-2 3/4"2'-8"5'-5 7/16"1'-6 1/2"4'-11"1'-6 1/2"
15'-2 7/8"
2'-6"
6 1/4"
6'-2"15'-6"
9'-5"
5'-8 13/16"
12'-3 1/4"
14'-7 15/16"
5'-7"
7'-7 1/16"
5'-1 3/4"
29'-8 13/16"
11'-3 1/2"
18'-2 1/2"
11'
8'
20'
40'
19'-8"
10'-3 1/4"
5'-8 13/16"
13'-9 7/16"
13'-5 1/16"
2'-4 3/16"
2'-8"7'-6 1/16"2
'-
8
"
1'-9 1/2"
13'
14'-10 3/8"
5'-8 1/2"
14'-10 3/8"
15'-7 1/2"
5'-5 7/8"
3'-8"
1'-3 15/16"5'-4"1'-4 1/16"
2'1'-4"8'1'-10 5/8"2'3'-11 3/8"8'3'-11 3/8"14'-6"13'-2 1/4"3'-8 5/16"2'-9 11/16"20'-6"
85'-9 5/8"
20'12'
85'-9 5/8"
3'-4"1'-9 1/4"5'-4 1/2"1'-9 1/4"3'-2"
6'-4 5/8"15'-5"11 3/4"15'-7 3/8"5'-6 3/4"3'-10"6'-0 1/8"
6'-0 1/2"
4'-11"
11 1/2"
4'-11"
7'-3 1/4"
4'-11"
1'-1 1/4"
4'-11"
5'-11 1/2"
41'
2'
1'
5'
2'
8'
2'
9'
7'-5 1/2"
13'-6 1/2"
2'-3 11/16"
2'-0 3/4"
54'-11 3/8"
19'-0 1/2"
3'-6 7/16"
5
1
/
2
"
1
'-
6
1
5
/
1
6
"
7
9
/
1
6
"
2
'-
8
"
7 1/8"1'-6 15/16"5 15/16"
2'-8"
7'-0 7/8"
5'-7"
15'-3 7/8"
6 1/4"
4'-11"
1 3/4"
5'-7"
3044 SQ FT
10'-7" X 9'-1"
10'-11" X 3'-7"
3'-4" X 9'-3"
16'-6" X 11'-11"
6'-6" X 9'-1"
2'-5" X 9'-11"
5'-9" X 7'-1"5'-6" X 7'-2"
15'-8" X 13'-5"
LIVING AREA
LAUNDRY BATH
BEDROOM
CLOSET
CLOSET
CLOSET CLOSET
STAIRWELL
KITCHEN
1st Floor
Existing Plan
Chugg Residence
2049 Uplands Cir
Estes Park CO, 80517
Evergreen + Elm Interior
Design Company LLC
SHEET:
SCALE:
DRAWINGS PROVIDED BY:
DESCRIPTION
DATE:
BY
DATE
NO.
PROJECT DESCRIPTION:
SHEET TITLE:
A-1
10.30.23
1/8"= 1'0"
North
Exisiting structure 4833 Square Feet. No additions to be made.
Wherever possible all new work is to be brought up to current code per the 2015 IECC requirements. Including moisture
barriers around new tub and shower.
All new lighting is to be field determined and installed by a licensed electriction to meet current code.
Demolition Wall Key:
- Wall to be Removed
-Existing Wall to Remain
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
11/17/2023
This installation must comply
with the requirements of the
2023 National Electrical Code
DN
UP
3 9/16"
4'-11"
4 7/16"
4"3'5 7/8"5'-5"6"5'-5"5 1/2"2'-4 1/4"2'-1 3/4"5'-4 3/8"7"2'-1 3/4"2'-9 3/4"
7'-9 3/4"4'-11"6 1/2"4'-11"2'-3 3/4"1'-9 1/8"12'-1"7 7/8"10 1/16"3'1'-2 3/4"2'-8"5'-5 7/16"1'-6 1/2"4'-11"1'-6 1/2"
15'-2 7/8"
2'-6"
5'-8 13/16"
12'-3 1/4"
14'-7 15/16"
6'-3 1/4"
7'-7 1/16"
5'-1 3/4"
11'-3 1/2"
18'-2 1/2"
11'
8'
20'
40'
19'-8"
10'-3 1/4"
5'-8 13/16"
13'-9 7/16"
13'-5 1/16"
2'-4 3/16"
2'-8"7'-6 1/16"2
'-
8
"
1'-9 1/2"
13'
14'-10 3/8"
3'-10 1/2"5'-2 7/8"
5'
4 1/2"5'
4'-7 1/2"
1'-3 15/16"5'-4"1'-4 1/16"
2'1'-4"8'1'-10 5/8"2'-2 1/4"3'-9 1/8"8'3'-11 3/8"14'-6"13'-2 1/4"3'-8 5/16"2'-9 11/16"20'-6"
85'-9 5/8"
20'12'
85'-9 5/8"
3'-4"1'-9 1/4"5'-4 1/2"1'-9 1/4"3'-2"
6'-4 5/8"15'-5"11 3/4"15'-7 3/8"9'-10 3/8"5'-6 1/2"
6'-0 1/2"
4'-11"
11 1/2"
4'-11"
7'-3 1/4"
4'-11"
1'-1 1/4"
4'-11"
5'-11 1/2"
41'
2'
1'
5'
2'
8'
2'
5'-5 1/2"
4'-3 1/2"
6'-8 1/2"
13'-6 1/2"
2'-3 11/16"
2'-0 3/4"
54'-11 3/8"
19'-0 1/2"
3'-6 7/16"
5
1
/
2
"
1
'-
6
1
5
/
1
6
"
7
9
/
1
6
"
2
'-
8
"
7 1/8"1'-6 15/16"5 15/16"
2'-8"
7'-0 7/8"
5'-7"
15'-3 7/8"
3 5/8"
4'-11"
1 3/4"
5'-4 3/8"
3048 SQ FT
10'-7" X 9'-1"
10'-11" X 3'-7"
2'-11" X 9'-6"
16'-6" X 11'-11"
6'-6" X 9'-1"
2'-5" X 9'-11"
5'-9" X 6'-4"5'-6" X 6'-5"
LIVING AREA
LAUNDRY BATH
BEDROOM
CLOSET
CLOSET
CLOSET CLOSET
STAIRWELL
Refinish existing hardwood
Remove carpet in kitchen and add tile
Partially remove exisiting tile and add matching hardwood
replace carpet
New tile flooring
New Finishes, Flooring and Cabinetry per Interior Designer
1st Floor
SHEET:
SCALE:
DRAWINGS PROVIDED BY:
DESCRIPTION
DATE:
BY
DATE
NO.
PROJECT DESCRIPTION:
SHEET TITLE:
A-2
Proposed Plan
Chugg Residence
2049 Uplands Cir
Estes Park CO, 80517
Evergreen + Elm Interior
Design Company LLC
10.30.23
1/8"= 1'0"
Gas line added for new gas range
Eliminating one Toilet and adding one tub
North
Exisiting structure 4833 Square Feet. No additions to be made.
Wherever possible all new work is to be brought up to current code per the 2015 IECC requirements. Including moisture
barriers around new tub and shower.
All new lighting is to be field determined and installed by a licensed electriction to meet current code.
FAN
General Notes:
-Min (1) emergency escape and rescue opening req’d per
bedroom
-Glazing to be tempered per R308
-Min (1) programmable thermostat req’d
-Smoke alarm req’d in each sleeping room
-Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior.
-Fireblock/Draftstop all chases and penetrations
2015 IECC
-75% OF LAMPS SHALL BE HIGH EFFICIENCY
Issuance of a permit or approval of these construction
documents shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions
of the adopted codes or of other ordinances of this jurisdiction.
A permit presuming to give authority to violate or cancel the
provisions of these codes shall be invalid. R105.4
Approved
by
SAFEbuilt
11/17/2023
12:28:07 PM
Natural
Gas
Supply
Water
Heater Fire
Place
Furnace
1”
1”¾”
¾”
1”
Proposed
Range
3/4”
Equipment BTU Length of Pipe Material
Water Heater 40,000 BTU 18’ Black Iron
Fire Place 40,000 BTU 32’ Black Iron
Furnace 88,000 BTU 40’Black Iron
Proposed Gas Range 40,000 BTU 24’Black Iron
Line inlet/ pressure drop 6” W.C 0.22 PSI
Address 2049 Uplands Circle
Estes Park, CO 80517
Permit #23-EP-00587
Approved
by
SAFEbuilt
11/17/2023
12:28:55 PM