Loading...
HomeMy WebLinkAboutPLANS 951 Black Canyon Dr Basement Finish 2019PP..OO.. BBOOXX 22006666 FFOORRTT CCOOLLLLIINNSS,, CCOO.. 8800552222 997700--447722--55666677 DN SB3021 SB3021 3DB1521 FHB21LRB363DB21 SB36 2DB15 TRASHDW3DB24 3DB24FHB21L FHB9R SB3021 SB3021 3DB1521 FHB21LRB363DB21 SB36 2DB15 TRASHDW3DB24 3DB24FHB21L FHB9R OTC302493 W421224 W2139R W2139LW3627 6068 3068FD 180703068 64310MU 64310MU 3068 5068 5068 5068 5068 64310MU 3068 3068 3068 3068 3068 3068 4568 E1E1 7 1/2"6'-4" 1'-0 1/2"1'-3" 2'9"2'-3 1/2"6'-4"3'-2 1/2"1'-8"3'8" 10" 2'3'-1 1/2"3'-3"2'3'-3"1'-6"3'2'18'1'-6" 20'-1 1/2"5'-5"6'-7 1/2"7'-4 1/2"5'-11 1/2"8'-6"26' 80' 21'-6"3'1'-6"3'-5 1/2"6'-4"2'-3" 26'12'-0 1/2"2'-5"2'-4 1/2"11'-10"5'-4"8'8'4' 2' 14' 14' 30' 15'-6" 2' 6'-6" 30' 4' 2' 2'-6 1/4" 2' 5 3/4" 6' 6" 2' 6" 8 3/4" 12'-6 1/2" 8 3/4" 3'-6" 3'-11 1/4"12'-10 1/2"6'-10 1/4" 25'-7" X 23'-3" 1419 SQ FT 7'-9" X 11'-8" 11'-5" X 15'-3" 2'-1" X 11'-7"2'-1" X 11'-7" 3'-8" X 1'-4" 11'-5" X 15'-3" 4'-3" X 7'-3" 6'-7" X 7'-8" 21'-3" X 16'-0" 5'-8" X 7'-7" 16'-3" X 6'-7" LIVING AREA GARAGEBEDROOM 1 BEDROOM 2 STAIRWELL CLOSET BATH 1 VANITY 1 CLOSET CLOSET UTILITY DECK NEW DECK LINEN NEW CONCRETE FP SURROUND (COLOR TBD) NEW CONCRETE COUNTERTOP SURFACE (COLOR TBD) COUNTERTOP OVERHANG 15" D X 12'10 W X 36" H (MATERIAL TBD) Project Date Scale Sheet No.Revision/Issue Date PROJECT: PPLLAANN NNOOTTEESS:: BUILDER RESERVES THE RIGHT TO MAKE ANY AND ALL CHANGES DUE TO CODE REQUIREMENTS, CONSTRUCTABILITY, HOA REQUIREMENTS, AND OR SUBSTITUTE ANY MATERIAL FOR A MATERIAL OF EQUAL OR GREATER VALUE AT THEIR SOLE AND ABSOLUTE DISCRETION. ALL MEASUREMENTS ARE APPROXIMATE. COMMERCIAL SPACES WILL BE BUILT IN SUBSTANTIAL ACCORDANCE WITH THESE PLANS CHANGES THAT ARE NOT A SUBSTANTIAL DEVIATION FROM THE PLAN ARE NOT GROUNDS TO CANCEL THE CONTRACT. A 1 10/9/2019 1/4" = 1'-0" ESTES PARK, COLORADO RODRIGUEZ REMODEL 951 BLACK CANYON DR. REMODEL MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" MAIN FLOOR PLAN Per response letter this deck will not be constructed at this time. Protection from fall is required at this opening Windows to comply with R308 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 12/18/2018 REVIEWED BY ______________________ CONSTRUCTION TYPE _______________ OCCUPANCY CLASSIFICATION ________ SPRINKLERED ______________________ 12/10/2019 This structure must comply with the requirements of the 2017 National Electrical Code LLA VB R3 No Reviewed by SAFEbuilt 12/10/2019 PP..OO.. BBOOXX 22006666 FFOORRTT CCOOLLLLIINNSS,, CCOO.. 8800552222 997700--447722--55666677 S S SB3021 3DB2421SB3021SB30213DB2421SB3021 WH 64310MU 30686068 3068 30683068 3068 64310MU 64310MU 2668 2668 6068 UP E1E1 7 1/2" 6'-4" 1'-0 1/2"8 1/2" 2' 1'-3 1/2" 5'-7"2'17'-8 1/2" 25'-3 1/2"6'-10"7'-5"7'-0 1/2"7'-7"25'-10" 80' 6'-4"4'-8 1/2"4'-7 1/2"6'-4"3'-3" 40'-6"14'-2 1/2"5'-3 1/2"8'8'4' 80' 2'-6 1/2" 2' 5 3/4" 6' 5 3/4" 2' 6" 8 3/4" 12'-6 1/2" 8 3/4" 2' 14' 14' 30' 24' 30' 4' 20'-11" X 26'-6" 1477 SQ FT 25'-3" X 22'-9" 10'-11" X 13'-7" 3'-3" X 1'-4" 13'-11" X 10'-3" 6'-6" X 6'-9" 6'-11" X 13'-0" 7'-2" X 6'-10" 11'-1" X 3'-0"6'-7" X 3'-0" 2'-0" X 6'-7" LIVING AREA UNEXCAVATEDFAMILY BEDROOM 4 VANITY 2 UTILITY BATH 2 BEDROOM 3 LINEN (3) SHELVES HALLCLOSET CLOSET 4" RAISED STEP 4" RAISED STEP Project Date Scale Sheet No.Revision/Issue Date PROJECT: PPLLAANN NNOOTTEESS:: BUILDER RESERVES THE RIGHT TO MAKE ANY AND ALL CHANGES DUE TO CODE REQUIREMENTS, CONSTRUCTABILITY, HOA REQUIREMENTS, AND OR SUBSTITUTE ANY MATERIAL FOR A MATERIAL OF EQUAL OR GREATER VALUE AT THEIR SOLE AND ABSOLUTE DISCRETION. ALL MEASUREMENTS ARE APPROXIMATE. COMMERCIAL SPACES WILL BE BUILT IN SUBSTANTIAL ACCORDANCE WITH THESE PLANS CHANGES THAT ARE NOT A SUBSTANTIAL DEVIATION FROM THE PLAN ARE NOT GROUNDS TO CANCEL THE CONTRACT. A 2 1/4" = 1'-0" REMODEL BASEMENT FLOOR PLAN SCALE: 1/4" = 1'-0" BASEMENT FLOOR PLAN 10/9/2019 ESTES PARK, COLORADO RODRIGUEZ REMODEL 951 BLACK CANYON DR. General Notes: -All rooms to be AFCI except bath, utility and unfinished rooms -Bath, utility and unfinished rooms to be GFCI -Backwater valves to remain accessible -1/2” dry wall req’d for enclosed usable space under stairs -Smoke alarms req’d in each sleeping room -Smoke/CO alarms req’d w/in 15’vicinity of bedroom exteriors -Min 1 emergency escape and rescue opening req’d per bedroom 2015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 Reviewed by SAFEbuilt 12/10/2019 Reviewed by SAFEbuilt 12/10/2019 PP..OO.. BBOOXX 22006666 FFOORRTT CCOOLLLLIINNSS,, CCOO.. 8800552222 997700--447722--55666677 DN R DW GD RRR T R CO/SD GFCI DM GFCIGFCI DM DM 7'6'-9"9'-11" 1'-5"5'5'8'-3 1/2" 1419 SQ FT LIVING AREA GARAGEBEDROOM 1 BEDROOM 2 STAIRWELL CLOSET BATH 1 VANITY 1 CLOSET CLOSET UTILITY DECK NEW DECK LINEN Project Date Scale Sheet No.Revision/Issue Date PROJECT: PPLLAANN NNOOTTEESS:: BUILDER RESERVES THE RIGHT TO MAKE ANY AND ALL CHANGES DUE TO CODE REQUIREMENTS, CONSTRUCTABILITY, HOA REQUIREMENTS, AND OR SUBSTITUTE ANY MATERIAL FOR A MATERIAL OF EQUAL OR GREATER VALUE AT THEIR SOLE AND ABSOLUTE DISCRETION. ALL MEASUREMENTS ARE APPROXIMATE. COMMERCIAL SPACES WILL BE BUILT IN SUBSTANTIAL ACCORDANCE WITH THESE PLANS CHANGES THAT ARE NOT A SUBSTANTIAL DEVIATION FROM THE PLAN ARE NOT GROUNDS TO CANCEL THE CONTRACT. E 1 1/4" = 1'-0" REMODEL ELECTRICAL MAIN FLOOR PLAN 10/9/2019 ELECTRICAL MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" ESTES PARK, COLORADO RODRIGUEZ REMODEL 951 BLACK CANYON DR. General Residential Electrical Requirements - Smoke detectors required inside and outside all bedrooms. - Min. one smoke detector required on each level. - Carbon monoxide detectors required within 15' of all bedrooms throughout home. - All outlets less than 5'6" AFF to be tamper resistant. - All circuits arc-fault except bathrooms and unfinished areas. - Min. (2) 20A, dedicated, GFCI/AFCI protected, small appliance, countertop circuits required in kitchens. - Min. (1) 20A, dedicated, GFCI protected outlet required within 36" of all lavs. - Garage circuits to be dedicated, 20A, and GFCI protected. - Laundry circuit to be 20A, GFCI protected. - All GFCI devices must be readily accessible. - Crawlspace lighting circuits to be GFCI protected. - Service receptacles required within 25' of all appliances. Reviewed by SAFEbuilt 12/10/2019 PP..OO.. BBOOXX 22006666 FFOORRTT CCOOLLLLIINNSS,, CCOO.. 8800552222 997700--447722--55666677 WH UP GFCIGFCI R R 3 3 GFCI C5/TV R R R RR R R R R R DM 1477 SQ FT LIVING AREA UNEXCAVATEDFAMILY BEDROOM 4 VANITY 2 UTILITY BATH 2 BEDROOM 3 LINEN HALLCLOSET CLOSET Project Date Scale Sheet No.Revision/Issue Date PROJECT: PPLLAANN NNOOTTEESS:: BUILDER RESERVES THE RIGHT TO MAKE ANY AND ALL CHANGES DUE TO CODE REQUIREMENTS, CONSTRUCTABILITY, HOA REQUIREMENTS, AND OR SUBSTITUTE ANY MATERIAL FOR A MATERIAL OF EQUAL OR GREATER VALUE AT THEIR SOLE AND ABSOLUTE DISCRETION. ALL MEASUREMENTS ARE APPROXIMATE. COMMERCIAL SPACES WILL BE BUILT IN SUBSTANTIAL ACCORDANCE WITH THESE PLANS CHANGES THAT ARE NOT A SUBSTANTIAL DEVIATION FROM THE PLAN ARE NOT GROUNDS TO CANCEL THE CONTRACT. ELECTRICAL BASEMENT PLAN SCALE: 1/4" = 1'-0" 1/4" = 1'-0" REMODEL ELECTRICAL BASEMENT PLAN 10/9/2019 E 2 ESTES PARK, COLORADO RODRIGUEZ REMODEL 951 BLACK CANYON DR. General Residential Electrical Requirements - Smoke detectors required inside and outside all bedrooms. - Min. one smoke detector required on each level. - Carbon monoxide detectors required within 15' of all bedrooms throughout home. - All outlets less than 5'6" AFF to be tamper resistant. - All circuits arc-fault except bathrooms and unfinished areas. - Min. (2) 20A, dedicated, GFCI/AFCI protected, small appliance, countertop circuits required in kitchens. - Min. (1) 20A, dedicated, GFCI protected outlet required within 36" of all lavs. - Garage circuits to be dedicated, 20A, and GFCI protected. - Laundry circuit to be 20A, GFCI protected. - All GFCI devices must be readily accessible. - Crawlspace lighting circuits to be GFCI protected. - Service receptacles required within 25' of all appliances. Reviewed by SAFEbuilt 12/10/2019