Loading...
HomeMy WebLinkAboutPLANS 621 Aspen Ave Solar PV 2020-06-29REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 TITLE SHEET N/A 11" X 17" 001 JMM T101 SHEET INDEX PROJECT PROJECT CONTACTS PROJECT DISCRIPTION OWNER&217$&7 CONTRACTOR DESIGN PROJECT SPECIFICATIONS M4 INDUSTRIES 970.685.1136 02'8/(0$.( 02'(/ 47< ,19(57(50$.(02'(/ 47< :$7767,/7$=,087+.:+<5 $55$< $55$< 727$/ $55$< $55$< 1(& ,%& '(6,*1&2'(67$1'$5'6 6<67(0$&5$7,1*6<67(0'&5$7,1* N: $ .9$ N: $ 9 ROMAN PV SYSTEM ROMAN621 621 ASPEN AVE ESTES PARK, CO 80517 AHJ: TOWN OF ESTES PARK / STATE OF COLORADO 2.835 KW GRID TIED FLUSH ROOF MOUNTED PV SYSTEM Kali Roman 970-619-1256 kaeliventura@gmail.com PEIMAR SG315M 9 ENPHASE IQ7 9 1575 18.4 189 2293 1260 33.69 33.69 1674 2835 3967 2.16 9 2.19 2.8 9.51 2017 2015 06.25.2020 A.ADKISSON ELECTRIC INC. 970.412.1988 ROMAN62 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 6-29-2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 SITE PLAN 1/16" = 1'-0" 11" X 17" 001 JMM C102 06.25.2020 SITE PLAN N PV ARRAY #2 (4) PEIMAR 315 MODULES (4) ENPHASE IQ7 INVERTERS 1260 WATTS 33.69 TILT 99 AZIMUTH 1674 KWH/YR PV ARRAY #1 (5) PEIMAR 315 MODULES (5) ENPHASE IQ7 INVERTERS 18.4 TILT 189 AZIMUTH 2293 KWH/YR UTILITY METER MDP PV AC DISCONNECT PV AC COMBINER PANEL AS P E N A V E . 6-29-2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ARRAY LAYOUT 1/8" = 1'-0" 11" X 17" 001 JMM PV103 06.25.2020 ARRAY LAYOUT ARRAY NOTES 1. EACH MODULE SHALL BE BONDED TO RACKING IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 2. MODULES SHALL BE INSTALLED IN ACCORDANCE WITH MODULE AND RACKING MANUFACTURER INSTALLATION MANUALS. 3. ARRAY SHALL BE INSTALLED SO NO MODULES ARE ABOVE THE RIDGE LINE ELEVATION. 4. ALL WIRES SHALL BE SECURED AND NOT IN CONTACT WITH THE ROOF SURFACE. A5 A2 A3 A4 A6 A7 A8 A9 A1 1'-6" 1' - 1 0 " 2'-7" 6-29-2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 RACKING LAYOUT 1/8" = 1'-0" 11" X 17" 001 JMM PV204 06.25.2020 SHEATHING ROOFING TRUSS PV MODULE ASTM F594 3/8" SERRATED FLANGE NUT 5/16" X 3-1/2 S.S. LAGBOLT 3/8 X 1-1/2 STAINLESS UNIRAC 304000C L-FOOT ASTM F593 3/8" - 16 HEX HEAD BOLT UNIRAC SOLARMOUNT BEAM UNIRAC END CLAMP OR MIDCLAMP UNIRAC 1/4"-20 T-BOLT W/ 1/4"-20 ASTM F594 SERRATED FLANGE NUT UNIRAC FLASHLOC ATTACHMENT DETAIL UNIRAC BONDING SPLICEBAR (4) #10 X 3/4" STAINLESS STEEL SELF DRILLING SCREWS STANDARD SPLICE DETAIL RIDGE LINE DETAIL RIDGE LINE ELEVATION INSTALLED MODULE (TYP) RACKING LAYOUT RACKING NOTES 1. BONDING IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 2. ALL RACKING COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUAL. 3. ATTACHMENT LOCATIONS ON THIS DRAWING ARE APPROXIMATE. FINAL ADJUSTMENT OF LOCATION MAY BE NECESSARY DEPENDING ON FIELD CONDITIONS. UNIRACFLASHLOC (TYP) UNIRAC SM RAIL (TYP) UNIRAC SPLICE (TYP) ENGINEERED TRUSS (TYP) 6-29-2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ONE LINE 1/8" = 1'-0" 11" X 17" 001 JMM E105 06.25.2020 +-+-+- 5 6 1 2 4 5 8 YELLOW PLACARD, BLACK LETTERING AT EXISTING METER - "PHOTOVOLTAIC SYSTEM CONNECTED". OUTDOOR JUNCTION BOX PV AC COMBINER PANEL, MIN 60A BUSS, (1)TWO POLE BREAKERS. STRING A: 20A. PROVIDE 240V, 30A NEMA 3R DISCONNECT. SHALL BE VISIBLE, ACCESSIBLE, LOCKABLE AND LABELED "PV AC DISCONNECT", LOCATED WITHIN 5' OF UTILITY BILLING METER. MICRO INVERTER, SEE TITLE BLOCK FOR SPECIFICATIONS NOTES: GENERAL NOTES: 7 SOLAR MODULE, SEE TITLE BLOCK FOR SPECIFICATIONS6 7 1 9 2 3 EXISTING MDP, 125A BUSS, 125A MAIN BREAKER. (1) EQUIPMENT SHALL BE INSTALLED AND LABELED IN ACCORDANCE WITH NEC 690 AND ALL APPLICABLE REQUIREMENTS BY UTILITY AND LOCAL AUTHORITY HAVING JURISDICTION. +-+-+-+-+-+- 20A BACK FEED BREAKER, LABELED: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 1 4 8 EXISTING METER 4 92 4 FEEDER SCHEDULE #6 BARE AWG GROUND1 ENPHASE Q CABLE (1) 12/2 ROMEX IN ATTIC SPACE 2 3 4 (3) #10 THWN, (1) #10 THWN GRND IN CONDUIT 6-29-2020 REV. NO.DESCRIPTION DATE DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM SHEET NO. ( AC DISCONNECT PV PRODUCTION METER(BRASS) 4 6 BACKFEED BREAKER 2 :,7+,1)72)0$,16(59,&( PLACARDSBILL OF MATERIALS QTY MAKE PARTNUMBER DESCRIPTION AC DISCONNECT 4 PHOTOVOLTAIC SYSTEM CONNECTED BILLING METER (YELLOW / BLACK LETTERS)1 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020 6 2 10 16 9 30 4 2 1 0 UNIRAC 315168D SM LIGHT RAIL 168" DRK UNIRAC 3030018D BONDING SPLICE BAR UNIRAC 302030D SM PRO SERIES UNIV MID CLAMP DRK UNIRAC 302035M SM PRO SERIES UNIV END CLAMP UNIRAC 08013S MICRO MNT BND T-BOLT 1/4" X 3/4" SS UNIRAC FLASH LOC UNIRAC 008009P WEEB LUG 9 PEIMAR SG315M PV MODULE 9 ENPHASE IQ7 INVERTER 9 ENPHASE Q CABLE ENPHASE Q TERM ENPHASE ENVOY/COMBINER SOLADECK 6-29-2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D107 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D309 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D410 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D511 RO M A N P V S Y S T E M 62 1 A S P E N A V E ES T E S P A R K , C O 8 0 5 1 7 ROMAN62 06.25.2020