HomeMy WebLinkAboutPLANS 1260 Big Thompson Antenna 2011\—
EXTERIOR ELEVATION
FLAG
LEASE AREA/
PROPERTY BOUNDARY
1.DRAWINGS ME NOT TO BE SCALED,WRITTEN DIMENSIONS TAI<E PRECEDENCE,AND THIS SET OF
PLANS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY,UNLESS NOTED OTHERWISE.THE
GENERAL CONTRACTOR’S SCOPE OF WORK SHALL INCLUDE FURNISHING AU.MATERIALS EQUIPMENT,
I.ASOR.MID ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS DESCRIBED HEREIN.
2.PRIOR TO THE SUBMISSION OF BIDS,‘THE CONTRACTORS II’WOLVED SHALL VISIT THE JOB SITE MD
FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT.WTTH THE
CONSTRUCTION AND CONTRACT DOCUMENTS,FIELD CONDITIONS AND CONFIRM THAT THE PROJECT MAY BE
ACCOMPUSHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.MW ERRORS,OMISSIONS.OR
DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING.
3.THE GENERAL CONTRACTOR SHALL RECEFQE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION
PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION
DRAWINGS/CONTRACT DOCUMENTS.
4,THE CONTRACTOR SI-JALL SUPERVISE MID DIRECT THE PROJECT DESCRIBED HEREIN.THE CON1RACTOR
SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEMIS.METHODS.TECHNIQUES,SEQUENCES
MAD PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
5.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO ItANUFACTURER’S/
VENDOR’S SPECIFiCATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE
PRECEDENCE.
6.ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SI-WI BE IN STRICT ACCORDANCE
WITH ALL AI’PUCABLE CODES,REGULATIONS.MID ORDINANCES.CONTRACTOR SHALL GF8’E ALL NOTiCES
MID COMPLY WITH ALL LAWS.ORDINANCES.RULES,REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY,MUNICIPAL AND UTILITY COMPANY SPECIFiCATIONS,MAD LOCAL MID STATE JURISDICTIONAL
CODES BEARING ON THE PERFORMMACE OF THE WORK.
7.THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS
CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE.
B.ANTENNA SUPPORTING STRUCTURE IS UNDER A SEPARATE CONTRACT.THE CONTRACTOR SHALL ASSIST
ANTENNA INSTALLATION SUBCONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS.ERECTION
SUBCONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF PERSONNEL AND PROPERTY FROM
HAZARDOUS EXPOSURE TO OVERHEAD DANGERS,
9.GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF CONSTRUCTION
DOCUMENTS UPDATED WITH THE LATEST REViSIONS MAD ADDENDA OR CLARIFICATIONS FOR THE USE BY
ALL PERSONNEL II-NQLVED Win-i THE PROJECT.
10.DE1’AILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN.MINOR MODIFICATIONS
MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS,AND SUCH MODIFiCATIONS SHALL BE
INCLUDED AS PART OF THE SCOPE OF WORK.
ii.THE FACILITY IS CELLULAR RADIO EQUIPMENT MAD ANTENNAS.
12.ThE CONTRACTOR SHAU.MARE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS,
EASEMENTS,PAVING,CURBING,ETC.DURING CONSTRUCTION UPON COMPLETION OF WORK.CONTRACTOR
SHALL REPAIR ANY DAMAGE THAT MAY RAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE
PROPERTY.
13.CON1RACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAR AND HAZARD FREE DURING
CONSTRUCTION MAD DISPOSE OF ALL DIRT,DEBRIS.RUBBISH AND REMOVE EQUIPMENT NOT SPECIFiED AS
REMAINING ON THE PROPERTY.PREMISES SHALL BE LEFT IN CLEAR CONDITION AND FREE FROM PAiNT
SPOTS,DUST.OR SMUDGES OF ANY NATURE.
14.THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION MID
CONTRACT DOCUMENTS TIlE COMPLETE SCOPE OF WORK,CONTRACTORS BIDDING THE JOB ARE
NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS MID OR
SPECIFiCATIONS SHALL NOT EXCUSE SAJD CONTRACTOR FROM COMPLETiNG THE PROJECT MAD
IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS,THE BIDDER SHALL BEAR THE
RESPONSIBILITY OF NOTIFYING (IN WRITING)THE ARCHITECT/ENGINEER OF MW CONFUCTS,ERRORS.OR
OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR’S PROPOSAL IN THE EVENT OF DISCREPANCIES
THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK,UNLESS DIRECTED OTHERWISE.
15.SPECIAL INSPECTION TESTING REQUIRED SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN
INDEPENDENT SPECIAL INSPECTOR PER SECTION 1701 OF THE UNIFORM BUILDING CODE (UBC)FOR THE
FOLLOWING:
A.CONCRETE:DURING THE TARING OF CONCRETE TEST SPECIMENS MAD PLACING STRUCTIJRAL
REINFORCING MAD STRUCTuRAL CONCRETE.VERIFY REINFORCING SIZE.PLACEMENT MID GRADE.
B.BOLTS.AND ANCHORS IN CONCRETE HOW—DOWN ANCHOR BOLTS.INSPECT SIZE.LENGTH.TYPE
(EXPANSION.EPOXY)MAD SPACING.
SITE ACQUISITIONIST
BLACK &VEATCH
PAM POWELL
6300 S.SYRACUSE WAY
SUITE #300
CENTENNIAL,CO 80111
PHONE:720.B34.4354
CONTRACTOR SHALL VERIFY ALL PLANS MID EXISTING DIMENSIONS
MAD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY
NOTIFY THE ARCHITECT IN WRITING OF MAY DISCREPANCIES
BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR
SAME.
THESE DRAWINGS ARE ONLY TO SCALE WHEN PLOTTED ON 24x36
SHEET.USE GRAPHIC SCALE WHEN PLOTTED ON 11x17 SHEET.
CALL BEFORE YOU DIG —COLORADO LAW REQUIRES 3 WORKING
DAYS NOTICE FOR CONSTRUCTION PHASE.
UTILITY NOTIFiCATION CENTER OF COLORADO —1—800—922—1987
ThESE DRAWINGS MAY NDT SHOW ALL UNDERCROIJND PIPING AND
U1TUI1ES,HE CONTRACTOR SHALL EXERCISE EXTREME CARE
DURING AU.EXCAVATION AND OTHER CONSTRUCTION ACTIVITIES.
CONTRACTOR IS RESPONSIBLE FOR ALL.UTiLITY LOCATES AND
UTiLITY RELOCATIONS REQUIRED FOR THIS INSTALLATION.
CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL WORK WITH
THE OWNER TO ENSURE NO DISRUPTION TO OWNERS OPERATIONS.
verin wireless
PROJECT:
PROJECT TEAM DRAWING INDEX
SITE 1.D.#:
SITE NAME:FTC ESTES PARK
SMR-MW &ANTENNA ADD
306
SHEET DESCRIPTIONOWNERCONTACT:
WALLACE J.&LAURINE
ANNA BURKE TRUST
1256 BIG THOMPSON AVE.
ESTES PARK.CO 80517
CONTACT:WALLACE BURKE
970.586.5793
CLIENT
VERIZON WIRELESS
CONSTRUCTION MANAGER
MIKE GIOVANNI
3131 5.VAUGHN WAY
SUITE 550
AURORA.CO 80014
CELL:303.489.0009
DESK:303.873.2620
ADDRESS:1260 BIG THOMPSON AVE.
ESTES PARK,CO 80517
RF ENGINEER
VERIZON WIRELESS
PRINCIPAL RI’ENGINEER
DAVID BORN
3131 5.VAUGHN WAY
SUITE 550
AURORA,CO 80014
PHONE:303.829.0002
ARCHITECTS
CHARLES STECKLY
CEll
5935 5.LANG ST.
SUITE 280
LIITLETQN,CO 80127
PHONE:303.932.9974
FAZ:303.932.6561
DRAWING SYMBOL LEGEND GENERAL NOTES
SECTION CUT
I
INTERIOR ELEVATION
FLAG
3
T1,O TITLE SHEET
A1.O SITE PLAN
Al.1 ENLARGED SITE PLAN
A2,O EQUIPMENT ROOM PLANS
A2.1 EQUIPMENT DETAILS
A2.2 RF PLAN
A2.3 RF PLAN
A3.O ELEVATIONS
verin wireless
VERIZON WIRELESS SERVICES
3 131 5.VAUGHN WAY,SUITE 550
AURORA.Co 80014
PNONE:303.873.2800
PROJECT INFDREWTION:
FTC ESTES PARK
SITE#306
1260 BIG THOMPSON AVE.
ESTES PARK.CO 81230
DETAIL OR PLAN
ENLARGEMENT
RE’fl DATE:DESCRIP’nON:By:
41 11121100 CD REVIEW IDA
9 01024111 OJBJTCOIAEOfIS IDA
C 04111012 CI.IETCOI*A04T0 800
0 04111112 CD 00 008
PLANS PREPARED Sc
PROJECT DATA VICINITY MAP
JURISDICTION:—TOWN OF ESTES PARK
ZONING DESIGNATION:—COMMERCIAL
OCCUPANCY GROUP:—U
CONSTRUCTION TYPE:—V—B
FULLY SPRINKLERED:—NO
GOVERNING CODES:
2009 IBC,2009 IMC,2009 IECC,2009 IEBC,201 1 NEC
ADA.COMPUMICE:
THIS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.
tOWN OF ESTES PARF
APPROVED
Building,DepartmentBy7zLDateZ’’t W7
iIding OfflcaI
REVISION
SPOT ELEVATION
GRID REFERENCE
ELECTRICAL
TELCO
ELEC &TELCO
COAXIAl.CABLE
GAS LINE
WATER LINE
SEWER LINE
SMIITARY SEWER
FiBER OPTiC CABLE
OVERHEAD UTILITIES
CHAIN LINK FENCE
WOODEN FENCE
EL.X
‘4)XXX
—E —
E/T—
—COAX——————
GAS
—w
SS—
—‘FIlER ——
—5280————
0,9
On.
CSA1
CHARLES STECKLY ARCHITECTURE,Inc.
ARONIIECIURE —PLANNING —DESIGN
5935 OBJIN ZM4G SWEET.JI1E 280
UTTLETON,Ca.CPAno 80127
C4’RCC 303.932.9974
FAX 303.932.656’
RAiLROAD TRACKS
STEEL STUD
BATT INSULATION
EXISTING TOPOGRAPHY
PROPOSED TOPOGRAPHY
WATER DRAINAGE FLOW
N.T.S.
PROJECT DESCRIPTION DIRECTIONS TO SITE
RELOCATE (2)EXISTING ONMI ANTENNAS MAD ADO (2)NEW OMNI FROM VERIZON WIRELESS OFFICE:TARE 1—70 WEST TO 1—270 WEST
ANTENNAS ON EXISTING BUILDING.INSTALL (1)NEW MW DISH ON TO US—SO WEST.CONTINUE ONTO C0—66 W/US—36 W/LITE I-FRY,
EXISTING EQUIPMENT SHELTER.TURN LEFT ONTO MAIN STREET.TAKE 2ND RIGHT ONTO CO—66
W/US—36.TURN RIGHT TOWARD BIG THOMPSON RD.TURN RIGHT
ONTO BIG THOMPSON RD.
SITE IS ON THE RIGHT.
GENERAL CONTRACTOR NOTE APPROVAL BLOCK
CONSULTANT:
ITTLE SIGNATURE DATE
OWNER
ENGINEER
CONSTRUCTION MGR.
PROJECT MANAGER
SHE Er TITLE:
ACKNDWI.EOGMENT OR ‘SIGN—OFr BY PARTIES TO THE CONSTRUCTION
DRAWINGS DOES NOT CONSTIIUTE ALTERAI1ON OF THE LEASE TERMS,
TITLE SHEET
SNEET NUMBER:
T1.O
M:
\
2
0
1
1’
P
r
c
e
V
i
%W
.
a
8M
R
F
T
t
E
Pa
t
I
FT
C
aa
4
r
r
c
Eg
i
s
Pw
t
’
C
D
A
l
.O
d
*
nn
r
r
E
o
o
11
.
12
AT
92
7
*
n
ft
q
I,
/•
/
/
/
U
NEW MD IS11NG VERZON
WIRELESS ANTENNAS
MOUNTED TO EXISTiNG
PARET.RE:A22
EXISI1NG COPY RUNNING
UP SIDE OF BUILDING
EXISTiNG
UNDERGROUND
COPY CONDUIT
EXISTING B—O
Unurr EASEMENT
CSAi
CHARLES STECKLT UCHITECTURE,Inc.
ARO-IITECIURE —PLANNING —DESIGN
5935 $0031 ZMIO SIREn.SIJIIE 260
IJT1LE1I..AOO I27flO32St14
C-,
C
U
I:
I!
a
0
EXISTiNG VERIZON
WIRELESS ONHI &4TENNA
MCUNTED TO
EXISTiNG VERIZDN
WiRELESS EDUPI/ENT
SHELTER
WWELESSMflSH
MOUNTED TO EXISTING \SHELTER.RE:A2.l EXISTiNG 3O•—0’
IJflLIW EASEMENT
verin wireless
VERIZON WIRELESS SERVICES
3 13 I S.VAUGHN WAY.SUITE 550
AURORA.CO 80014
PHONE:3030732800
‘260 BIG THOMPSON AVE
ESTES PJOE.CO RI 230
EXISTING GRAIN
LINK FENCE
EXISTING ICE
BRIDGE
EXISTING 2D—0
UT1UTY EASEMENT
<S30’ENLARGED
SITE PLAN
PW
I
T
h
D
1,
21
2
AT
W2
7
a
n
,
AC
M:
\
2
0
1
l\
P
r
o
j
e
c
l
s
W
e
r
l
z
o
n
WI
r
.
T
c
o
,
SM
R
’
F
l
C
Ea
t
e
a
Pa
n
t
&
FT
C
Sb
i
n
i
n
g
F
T
C
Ea
t
e
s
Pa
r
k
C
D
2
.
i
dw
g
PL
O
r
T
E
D
Ap
t
II
.
20
1
2
AT
9:
2
7
a
m
—
‘4
r
rn a,
a
C)0zm
nf
l
*1
r
H
I
—
çi
j
ci
)
SP
A
C
E
SP
A
C
E
Ph
wo
o
mE —rmUz H
C)x
4
‘“2 3/8’SCHD.
N.4OPIPEN-U PIPE CLAMP (TYP)
Nrn
PMNT ALL MOUNTiNG
RARDWARE &PIPE MAST
TO MATCH (E)BUILDING
1.GENERAL:PROViDE ALL LABOR,EQUIPMENT AND MATERIALS NECESSARY FOR RECEMNG.INSTALLiNG.TESI1NG
MID ADJUSTING ANTENNA CABLES FROM THE ANTENNA TO THE CONNECTORS AT THE BASE TRANSMISSION
SYSTEM (BTS).THIS SI-tALL INCLUDE ALL EQUIPMENT SHOWN OR REQUIRED FOR A COMPLETE DPER&T1NG
SYSTEM.ANTENNA,ANTENNA CABLES,CONNECTORS AND FITtiNGS SHALL BE THIRD PARTY FURNISHED
COMPONENTS AS SHOWN ON THE BILL OF MATERIALS.
2.MATERLALS
A.ANTENNA CABLES:AS SCHEDULED
B.ANTENNA CDNNECTORS:AS SCHEDULED
C.CABLE HANGERS:INSTAllED AT MAXIMUM 4’SPACING
D.GROUNDING KITS:AS SPECIFiED
/
7/C
EXiSTiNG GABLE ROOF
3,INSTALLATION
A.ANTENNA CABLE LENGTHS SHALL BE FiELD MEASURED PRIDR TO PURCHASE OF CABLE.INSTALLER SI-CALL
NOTIFY VZW OF THE OVERALL LENGTH REQUIRED,
B.CABLES SHAll.BE LABELED IN ACCORDANCE WITH VZW SPECIFICATIONS.
C-NJ,OUTSIDE CABLE CONNECTIONS SHALL BE CJA’ERED WITH WEATHERPROOFING TAPE.
D.THE MINIMUM BENDING RADIUS FOR ALL M4TENI-L4 CABLES SHALL BE AS SHOWN BELOW OR AS PER THE
MANUFACT1JRER.WECHEVER IS MORE CONSERVATIVE:
CABLE IN MR /CABLE TRAY IN CONDUIT
1/2’5 10’
1 5/8’20’23’
E.CABLES SHALL BE INSTALLED WITH THE MINIMUM NUMBER OF BENDS.CABLES SHALL NOT BE LEFT
UNTERMINATED IN THE FiELD.
F.GROUNDING KITS —AFTER INSTALLATION OF GROUND STRAPS,THE CONNECTION SHALL BE MADE WEATHER
TiGHT USING WEATHERPROOFING KITS AS IDENTiFiED ABDVE.GROUND PICTAJLS SHALL BE BROUGHT OUT IN
THE DOWNWARD DIRECTION FROM THE CONNECTIONS TO THE ANTENNA CABLE WITHOUT AW SHARP BENDS
(MINIMUM BEND RADIUS 10”)AND CONNECTION SHALL BE MADE TO GROUNDING SYSTEM.
10”
verirnn wireless
VERIZON WIRElESS SERVICES
3131 S.VAUGHN WAY.SUiTE 550
AURORA.CO BOO 14
PHONE:303.873.2800
18’
PROJECT FqFOR,.tATION:
/FTC ESTES PARK
SITE#306
260 BIG THOMPSON AVE.
ESTESPAncCOBI23O
ANTENNA NOTES AND REQUIREMENTS
(E)OI-AN M’4TENNA-
EXISTING COAX
MOUNTED TO PARAEF
EXISTING PAlAPET
3FF
21 EXISTING ANTENNA CONFIGURATION
REV:DATE:DESCRIP’noN:By:
A 110Itl1 COREVEW fli
B I1,2At11 QJENT BsenS ELI
C 04,1a11 cliENT lSIEN’S ISO
0 04111t13 CO1f ASS
PLANS PREPARED By:
z
-PIPE TO PIPE
TRANSFER KIT (TIP)
(2)5/fl MASONRY ANCHORS
W/3 EMBED INTO FULLY
GROEJTED CELLS (TIP)
-15’P1000 UNISTRUT (TIP)
//
/—(E)EIFS ON CMU
km .--‘,—(2)5/B’S MASONRY.L/ANCHORSW/3’:1!EMBEDINTOFUU,Y
_____________
C-ROUTED CELLS (nP)
9
fl -4
\N ‘lS”P1000 IJNISTRUT
T&B (TIP)
4.
CSA1
CHARLES STECIELY CHITECTURE,Inc.
ARCHIIECI1JRE —PLANNING —DESIGN
5035 SOUTh ZMIQ STREET.SiRE 280
LITiLE1I.W.OIAOO I27fla:o5A3zSi4Fflfl932.S5SI
_O.
EX GABLE R /
-EXIS’RNG ROOF
ANTENNA MOUNT PLAN
NEW ANTENNA MOUNTS
TO MATCH (E)
RE:3/A2.2
INSTALL BRACKETS FOR
FUTURE INSTALLATION
0’
EIFS ON CMU
ANTU4FM WXMT SECTION
CONSULTANt
MOUNT COAX TO —
EXISTING PARAPET
EXISTING PAET
(3)EXISTING COAX UP SIDE OF BUILDING &
(3)COAX AVMLABLE TO INSTALL JUMPERS TD
NEW VERIZDN WIRELESS ANTENNAS.ATTACH W/
SS CUPS 0 4—0’CC.VERTICAL TD (E)
UNISTPIJT—PAINT TO MATCH EXISTING BUILDING
SHEET T-rTL
RE PLAN
SHEET Nw-lEER:
A2.2
PLAN &SECTION @ ANTENNAS
I t PROPOSED ANTENNA CONFIGURATION
I
I
—
p
________
I.
4
2
O
1
1
’
P
,
a
c
’
V
e
h
m
n
We
on
SM
R
F
r
C
Es
t
o
s
Pa
i
*
&
FT
C
St
t
k
i
g
T
C
Es
l
e
s
Pt
C
C
3
.
O
.
&
a
g
PL
O
T
T
E
D
Al
1
.
2
O
l
2
AT
g2
7
a
s
u
±2
8
—
4
TO
.
EX
I
S
T
i
N
G
SI
J
I
I
.
D
N
G
,
:o
z
mm
w C’
-o UI