Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS 800 Big Thompson Ave Solar PV System 2020
°ßYcĎcßYcßĬĎìœcĒĠşĠĬcÝĠƶ°ßIƳ ɪĄ̏ɪ Ðljlj ©DZǷǷ YʞDZ̕lj ɜ˖ȋƶ Gɞ˞Ƿƻljʞƶ Iì Ų̌ˌ̨ȋ ĎǯɞɊljƲ ˌ̨ˌƳȋȋˌƳ̨ɪɪȀ ŵ̛Ʋ ˌ̨ˌƳȋȋˌƳ˖ɪʲˌ ̖̖̖ƳʧɞǷŵʞDZɾʧƳƨɞɄ Tuesday,December 17, 2019 Town of Estes Park 170 MacGregor Ave Estes Park, CO 80507 Re: Structural Adequacy of Roof, Roof Attachments, and Racking System at 800Big Thompson Ave, Estes Park, CO 80507 Dear Sir or Madam, We have evaluated the roof, roof connections, and racking system for the photovoltaic array to be installed at the buildingreferenced above. UltimateWind Speed = 175mph Wind Exposure Category = C GroundSnow Load = 66psf The roof framing membersare2x6Trussandare 24O.C, supporting minimum 7/16OSB,and anasphalt shingleroof. The PV system to be installed at the residence is flush-mounted with no overhang. The roof structure has been evaluated under the above listed design loads and the addition of solar will not cause any member to be over stressed. The PV system to be installed at the residence will utilize Iron Ridgeracking system. The PV System layout has been designed to conform to the above listed design criteria, ASCE 7-10, and Ironridge Installation Manual. Attachments are to be spaced a maximum of 4488lbs and max uplift of 534lbs. These values are within the engineering design loads of the solar attachment and the solar rail, so the system is deemed adequate for this installation. Sincerely, Independent Power Systems, Inc. By: ______________________________________ Anthony P. Boniface, PE President Independent Power Systems Description PV 0 Date Discovery Lodge Cover Sheet Estes Park, CO 80517 Boulder, CO 80301 Fax: 303.443.2173 800 Big Thompson Ave. 1501 Lee Hill Dr. #24 Phone: 303.443.0115 No. Notes:Revision Schedule Customer: Subs: Contacts: Town of Estes Park 201520152017 175 mphVult66 psf Wind Speed: Permitting Jurisdiction: Roof Snow Load: IBC Code Cycle: IRC Code Cycle: NEC Code Cycle: Building and Code Info: YesAttachment Detail 92.84 kW72.2" x 40" x 1.57"ZillaMount Double Stud88Site PlanString Map (211) SPR-A21-440-COM(2) SE5000H-US(4) SE10000H-US(2) SE11400H-US(211) P505Comp ShingleEstes Park120/240 VAC120/240 VAC5766Cover SheetPV Layout 1PV Layout 2PV Layout 3Building A Line DiagramBuilding B Line DiagramBuilding C Line DiagramBuilding A Electric CalcsBuilding B Electric CalcsBuilding C Electric Calcs Iron Ridge Module Dimension:Attachments:Attic Space:Tilt: Azimuth:Tilt: Azimuth:Tilt: Azimuth: System Size:Optimizer: System AC Voltage:# of Panels# of Panels# of Panels Panel Model:Racking Model:Roof Type:Utility:Building Voltage:Sheet Index:PV 0PV 1PV 2PV 3.1PV 3.2PV 3.3PV 4 PV E1.1PV E1.2PV E1.3PV E2.1PV E2.2PV E2.3 Inverter Model: Project Info:Layout 1:Layout 2:Layout 3: Description PV 1 Date Site Plan Discovery Lodge 2/24/2020 Estes Park, CO 80517 800 Big Thompson Ave. Boulder, CO 80301 Fax: 303.443.2173 1501 Lee Hill Dr. #24 1 Phone: 303.443.0115 No. Revision Schedule System Size: 92.84 kW Notes: Building A Building C Building B custom Site PlanScale: 1 Description Discovery Lodge Estes Park, CO 80517 Boulder, CO 80304 800 Big Thompson Ave. Fax: (303) 443-2173 Phone: (303) 443-0115 1501 Lee Hill Drive #24 No.Date -2 screws in rafters Notes:.Revision Schedule " x 4" 16 5 Lag (x2) PV Module Truss Top Chord " OSB 2 1 Zilla Double StudDecking IronRidge with UFO Clip 2 193/256" = 1' L-Foot Connection: Attachment Detail Scale: 2.1 5/16" Stainless Steel Hardware Roofing Asphalt Shingle (in)NANANA Full Tributary Description 484848 (in) PV 3.1 Attachment Spans Layout 1 Date Half Tributary Discovery Lodge Roof/Wall Zone Length = 3' Estes Park, CO 80517 800 Big Thompson Ave. Boulder, CO 80301 Fax: 303.443.2173 1501 Lee Hill Dr. #24 Phone: 303.443.0115 1 23 Zone No. -PV Array 1 is on Building A Notes:Revision Schedule " 1 2 1'-6" 12'-0 " " 8 8 5 5 154"154" 153 149 168"168" 204"204" 204"204" 204"204" " 1 4 14' Iron Ridge17' Iron Ridge " 94'-2 1 2 204"204" 97'-6 204"204" 204"204" 204"204" Custom Scale: Layout 204"204" 3.1 204"204" " 1 2 4'-10 3' (in)NANANA Full Tributary Description 484848 (in) PV 3.2 Attachment Spans Date Half Tributary Layout 2 Discovery Lodge Roof/Wall Zone Length = 3' Estes Park, CO 80517 800 Big Thompson Ave. Boulder, CO 80301 Fax: 303.443.2173 1501 Lee Hill Dr. #24 Phone: 303.443.0115 1 23 Zone No. -PV Array 2 is on Building B Notes:Revision Schedule " 3' 1 2 12'-0 " 1 2 1'-3 149"149"149"149" 168"168"168"168" 204"204"204"204" 204"204"204"204" 14' Iron Ridge17' Iron Ridge 111' 204"204"204"204" 204"204"204"204" 0.006191 LayoutScale: 3.2 204"204"204"204" (in)NANANA Full Tributary Description 484848 (in) PV 3.3 Attachment Spans Date Half Tributary Layout 3 Discovery Lodge Roof/Wall Zone Length = 3' Estes Park, CO 80517 800 Big Thompson Ave. Boulder, CO 80301 Fax: 303.443.2173 1501 Lee Hill Dr. #24 Phone: 303.443.0115 1 23 Zone No. -PV Array 3 is on Building C-PV array area is 33% of the building plan area. Per IFCridge setback no less than 18inches Notes:1204.2.1.3 we are able to have aRevision Schedule " 1 2 1'-6" 12'-0 6'-9" 149"149"149"149" 204"204"204"204" 204"204"204"204" 204"204"204"204" 204"204"204"204" " 1 4 14' Iron Ridge17' Iron Ridge 148'-0 204"204"204"204" 204"204"204"204" 204"204"204"204" 204"204"204"204" 3' KRW 3/12/2020 1" = 19.7492' Ďőȋ Discovery Lodge Beverly, MA 01915 Fax: (978) 969-3410 54 W Dane St. Unit F Estes Park, CO 80517 Phone: (978) 9984079 ĠǹʞDZɊȔ Ýŵɾ 800 Big Thompson Ave. Yŵǹlj ĠƨŵǷlj Yʞŵǩǹljʞ Ďʞɞdzljƨǹ °ɊǩɞʞɄŵǹDZɞɊ cɊȔDZɊljljʞ Ēlj̕DZlj̖ Sheet No. ȧʁɑʃ Ʉɞƻ˞Ƿlj ʧǹʞDZɊȔ ɄDZɊDZɄ˞Ʉȧʁɪˌʃ Ʉɞƻ˞Ƿlj ʧǹʞDZɊȔ Ʉŵ̛DZɄ˞Ʉ ßɞǹljʧƲƳ 17 16 4 9 18 12 3 5 1519 8 11 2 Array 2Array 3 Array 1 (1 String of 12 modules) \[6\] 5 kW Inverter G (2 strings of 7 modules) \[19,20\] 5 kW Inverter H (2 strings of 7 modules) \[21,22\] 11.4 kW Inverter A (3 string of 9 modules) \[1,2,3\]11.4 kW Inverter B (2 string of 9 modules) \[4,5\] 10 kW Inverter E (3 strings of 10 modules) \[13,14,15\]10 kW Inverter F (3 strings of 10 modules) \[16,17,18\] 20 10 kW Inverter C (3 strings of 11modules) \[7,8,9\]10 kW Inverter D (3 strings of 11 modules) \[10,11,12\] 14 6 1 7 21 10 22 13 Description Discovery Lodge Boulder, CO 80301 Fax: 303.443.2173 Estes Park, CO 80517 1501 Lee Hill Dr. #24 Phone: 303.443.0115 800 Big Thompson Ave No.Date Revision Schedule Notes ay 20301010 (ft) ~1-w length x10 Cu 1 x #6 1 x #121 x #10 THWN-2THWN-2THWN-2 type/size conductor Grounding 1 x #10 Bare x 1 x #11 x #1 1 x #6 Neutral THWN-2THWN-2THWN-2 type/size conductor type/size conductor 2 x #1THWN-22 x #1THWN-2 Current carrying 12 x #12 THWN-2 NA12 x #10 PVx " EMT2 x #6THWN-2 4 3 1" EMT Conduit type/size 1 1/2" EMT1 1/2" EMT Description AC Disconnect to MSP Combiner Panel to AC Disconnect PV Array to Transition BoxInverter to Combiner Panel 1 2Transition Box to Inverter34 5 TAG P505 Description System Information Equipment TAG Description Discovery Lodge Boulder, CO 80301 Fax: 303.443.2173 Estes Park, CO 80517 1501 Lee Hill Dr. #24 Phone: 303.443.0115 800 Big Thompson Ave No.Date Revision Schedule 8 Notes MSP 200A, 2P 7 7 ay 2020303010101050UTILITY PEDESTAL (ft) ~1-w length 6 X10 CuCu 1 x #61 x #6 1 x #121 x #121 x #101 x #10 THWN-2THWN-2THWN-2THWN-2THWN-2THWN-2 type/size conductor Grounding 1 x #10 Bare1 x #10 Bare 6 1 x #6 Neutral 1 x #10 THWN-2THWN-21 x #1/0THWN-21 x #1/0THWN-21 x #1/0THWN-2 type/size conductor 5 5 type/size conductor Current carrying 2 x #1/0THWN-22 x #1/0THWN-22 x #1/0THWN-2 30A, 2P60A, 2P60A, 2P e NA12 x #10 PVxNA4 x #10 PVx" EMT4 x #12 THWN-2x" EMT2 x #10THWN-2" EMT2 x #6THWN-2 444 2" PVC 2" EMT2" EMT 333 1" EMT16 x #12 THWN-2x Conduit type/siz 3 4 4 Description EXTERIOR WALL BUILDING B 344 111 22323 5 kW Inverter G: 2 strings of 710 kW Inverter D: 3 strings of 11 10 kW Inverter C: 3 strings of 11 Transition Box to transition boxAC Disconnect to AC DisconnectAC Disconnect to MSP Combiner Panel to AC Disconnect PV Array to Transition BoxPV Array to Transition BoxInverter to Combiner PanelInverter to Combiner Panel 347 56 2a 1a1b2bTransition Box to Inverter TAG 2b 2a BUILDING B ROOF Transition BoxTransition Box P505 Description 1a1b 22 6 strings of 11 modules System Information 11 Array 2: Array 3: 2 strings of 7 modules 22 Equipment BUILDING C ROOF TAG Description Discovery Lodge Boulder, CO 80301 Fax: 303.443.2173 Estes Park, CO 80517 1501 Lee Hill Dr. #24 Phone: 303.443.0115 800 Big Thompson Ave No.Date Revision Schedule Notes 8 MSP 200A, 2P 7 7 ay 2010101050 (ft) 130 ~1-w UTILITY PEDESTAL length 6 X10 Cu 1 x #61 x #6 1 x #121 x #101 x #10 THWN-2THWN-2THWN-2THWN-2THWN-2 type/size conductor Grounding 1 x #10 Bare 6 1 x #6 Neutral 1 x #10 THWN-2THWN-21 x #1/0THWN-21 x #1/0THWN-21 x #1/0THWN-2 type/size conductor 5 5 type/size conductor Current carrying 2 x #1/0THWN-22 x #1/0THWN-22 x #1/0THWN-2 30A, 2P60A, 2P60A, 2P e NA16 x #10 PVx" EMT2 x #10THWN-2" EMT2 x #6THWN-2 44 2" PVC 2" EMT2" EMT 33 1" EMT16 x #12 THWN-2x Conduit type/siz 3 4 4 Description EXTERIOR WALL BUILDING B 344 111 222 AC Disconnect to AC DisconnectAC Disconnect to MSP Combiner Panel to AC Disconnect PV Array to Transition BoxInverter to Combiner PanelInverter to Combiner Panel 5 kW Inverter H: 2 strings of 710 kW Inverter E: 3 strings of 1010 kW Inverter F: 3 strings of 10 1 2Transition Box to Inverter347 56 TAG 2 BUILDING C ROOF Transition Box P505 Description 1 2 6 strings of 10 modules2 strings of 7 modules System Information 1 Array 3: 2 Equipment TAG 15306060 125 68.2568.25 131.95 690.9(B) 132-14096-10496-10496-104 F)F)F) F) °°° ° === Fuse Wire (Amps):per NEC Ampacity NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a) 0.910.910.91 Ambient Temp (Ambient Temp (Ambient Temp ( NEC Table 310.15(B)(2)(a)Ambient Temp (AmpsAmpsAmps Breaker/Fuse (Amps)Breaker/Fuse (Amps)Breaker/Fuse (Amps) 19.2 13.6317.03 1" EMT1" EMT 3/4" EMT3/4" EMT === Temp:Temp:Temp: ambient ambient ambient 59.37559.375118.75 De-rate for De-rate for De-rate for xxx === 1.251.25 0.71 Conduit Size/Type:Conduit Size/Type:Conduit Size/Type:Conduit Size/Type: Temp: De-rate for ambient PV E2 / 111 1-31-31-31-3 Electrical Calcs 1.251.251.25 ))) 1 Continuous DutyContinuous DutyContinuous Duty De-rate for # of Current Carrying De-rate for # of Current Carrying De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a) ((( (De-rate for # of Current Carrying (Continuous Duty) Inverter Output CircuitInverter Output CircuitInverter Output Circuit Conductors NEC 310.15 DC Circuit 690.8(A) / xxxxxxx x Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: NEC 690.8 NEC 690.8 NEC 690.8 757595 145 10.947.547.5 C C C C 13.6313.63 °°°° Single String-PV Source Circuit 690.8(A) (Design factor for environmental condtions) at 90 at 90 at 90 at 90 #6 THWN-2#6 THWN-2#1 THWN-2 #12 THWN-2 NEC 310.15(B)(16)NEC 310.15(B)(16)NEC 310.15(B)(16) Wire Ampacity per Wire Ampacity per Wire Ampacity per PV source Ciruit*AWG #10 PV Listed per NEC 690.31(B)De-rated Ampacity of the conductor (Amps):Maximum Circuit Current:(Module Isc)690.8(B)(1)690.8(B)(2)Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps): 15306060 150 36.4 68.25154.7 690.9(B) 132-14096-10496-10496-104 F)F)F) F) °°° ° === Fuse Wire (Amps):per NEC Ampacity NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a) 0.910.910.91 Ambient Temp (Ambient Temp (Ambient Temp ( NEC Table 310.15(B)(2)(a)Ambient Temp (AmpsAmpsAmps Breaker/Fuse (Amps)Breaker/Fuse (Amps)Breaker/Fuse (Amps) 19.2 13.6317.03 1" EMT1" EMT 3/4" EMT3/4" EMT === 52.5 Temp:Temp:Temp: 26.25 ambient ambient ambient 131.25 De-rate for De-rate for De-rate for xxx === 1.251.25 0.71 Conduit Size/Type:Conduit Size/Type:Conduit Size/Type:Conduit Size/Type: Temp: De-rate for ambient PV E2 / 111 1-31-31-31-3 Electrical Calcs 1.251.251.25 ))) 1 Continuous DutyContinuous DutyContinuous Duty De-rate for # of Current Carrying De-rate for # of Current Carrying De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a) ((( (De-rate for # of Current Carrying (Continuous Duty) Inverter Output CircuitInverter Output CircuitInverter Output Circuit Conductors NEC 310.15 DC Circuit 690.8(A) / xxxxxxx x Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: NEC 690.8 NEC 690.8 NEC 690.8 21404275 105170 10.9 C C C C 13.6313.63 °°°° Single String-PV Source Circuit 690.8(A) (Design factor for environmental condtions) at 90 at 90 at 90 at 90 #6 THWN-2 1/0 THWN-2 #12 THWN-2#10 THWN-2 NEC 310.15(B)(16)NEC 310.15(B)(16)NEC 310.15(B)(16) Wire Ampacity per Wire Ampacity per Wire Ampacity per PV source Ciruit*AWG #10 PV Listed per NEC 690.31(B)De-rated Ampacity of the conductor (Amps):Maximum Circuit Current:(Module Isc)690.8(B)(1)690.8(B)(2)Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps): 15306060 150 36.4 68.25154.7 690.9(B) 132-14096-10496-10496-104 F)F)F) F) °°° ° === Fuse Wire (Amps):per NEC Ampacity NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a)NEC Table 310.15(B)(2)(a) 0.910.910.91 Ambient Temp (Ambient Temp (Ambient Temp ( NEC Table 310.15(B)(2)(a)Ambient Temp (AmpsAmpsAmps Breaker/Fuse (Amps)Breaker/Fuse (Amps)Breaker/Fuse (Amps) 19.2 13.6317.03 1" EMT1" EMT 3/4" EMT3/4" EMT === 52.5 Temp:Temp:Temp: 26.25 ambient ambient ambient 131.25 De-rate for De-rate for De-rate for xxx === 1.251.25 0.71 Conduit Size/Type:Conduit Size/Type:Conduit Size/Type:Conduit Size/Type: Temp: De-rate for ambient PV E2 / 111 1-31-31-31-3 Electrical Calcs 1.251.251.25 ))) 1 Continuous DutyContinuous DutyContinuous Duty De-rate for # of Current Carrying De-rate for # of Current Carrying De-rate for # of Current Carrying Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a)Conductors NEC 310.15 (B)(3)(a) ((( (De-rate for # of Current Carrying (Continuous Duty) Inverter Output CircuitInverter Output CircuitInverter Output Circuit Conductors NEC 310.15 DC Circuit 690.8(A) / xxxxxxx x Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: Number of Current Carrying Conductors: NEC 690.8 NEC 690.8 NEC 690.8 21404275 105170 10.9 C C C C 13.6313.63 °°°° Single String-PV Source Circuit 690.8(A) (Design factor for environmental condtions) at 90 at 90 at 90 at 90 #6 THWN-2 1/0 THWN-2 #12 THWN-2#10 THWN-2 NEC 310.15(B)(16)NEC 310.15(B)(16)NEC 310.15(B)(16) Wire Ampacity per Wire Ampacity per Wire Ampacity per PV source Ciruit*AWG #10 PV Listed per NEC 690.31(B)De-rated Ampacity of the conductor (Amps):Maximum Circuit Current:(Module Isc)690.8(B)(1)690.8(B)(2)Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps):Maximum Inverter Output Current:Inverter Output De-rated Ampacity of the conductor (Amps): E3.00 Additional Notes PV System Labeling Fax: (303) 443-2173 Phone: (303) 443-0115 1501 Lee Hill Dr. Unit 24 Boulder, CO 80304-5602 B B 76& mbshfs 261& 251& 241& Vq!up 231& !TvoQpxfs!B.Tfsjft!Qbofmt 71& 221& Npsf 211& Mjgfujnf :1& Fofshz 91& Dpowfoujpobm!Qbofm 81& 71& 1621263136 Zfbst!pg!Pqfsbujpo 51!nn \\2/68!jo^ 2:::!nn \\89/8!jo^ 2127!nn )B* \\51/1!jo^ GSBNF!QSPGJMF C )B*!Dbcmf!Mfohui;!2431!nn!\\63!jo^ )C*!Mpoh!Tjef;!41!nn!\\2/3!jo^! !!!!!!Tipsu!Tjef;!33!nn!\\1/:!jo^! TpmbsFehf!Qpxfs!Pqujnj{fs Npevmf!Bee.PoGps!Opsui!Bnfsjdb Q411!0!Q431!0!Q481!0!Q511!0!Q516 PV power optimization at the module-level Up to 25% more energy TpmbsFehf!Qpxfs!Pqujnj{fs Npevmf!Bee.Po!gps!Opsui!Bnfsjdb Q411!0!Q431!0!Q481!0!Q511!0!Q516 P370 P300P320P400P405 (for higher-power (for 60-cell mod-(for high-power (for 72 & 96-cell 60 and 72-cell ules)60-cell modules)modules)modules) modules) INPUT W % % II RoHS % 2525 W ª!TpmbsFehf!Ufdiopmphjft-!Jod/!Bmm!sjhiut!sftfswfe/!TPMBSFEHF-!uif!TpmbsFehf!mphp-!PQUJNJ\[FE!CZ!TPMBSFEHF! bsf!usbefnbslt!ps!sfhjtufsfe!usbefnbslt!pg!TpmbsFehf!Ufdiopmphjft-!Jod/!Bmm!puifs!usbefnbslt!nfoujpofe!ifsfjo!bsf! usbefnbslt!pg!uifjs!sftqfdujwf!pxofst/!Ebuf;!1403128!!W/13/!Tvckfdu!up!dibohf!xjuipvu!opujdf/ TpmbsFehf!Tjohmf!Qibtf!Jowfsufst! GpsOpsui!Bnfsjdb! TF4111B.VT!0!TF4911B.VT!0!TF6111B.VT!0!TF7111B.VT!0 TF8711B.VT!0!TF21111B.VT!0!TF22511B.VT The best choice for SolarEdge enabled systems www.solaredge.us Tjohmf!Qibtf!Jowfsufst!gps!Opsui!Bnfsjdb! TF4111B.VT!0!TF4911B.VT!0!TF6111B.VT!0!TF7111B.VT!0! TF8711B.VT!0!TF21111B.VT!0!TF22511B.VT 33 3333333 ª!TpmbsFehf!Ufdiopmphjft-!Jod/!Bmm!sjhiut!sftfswfe/!TPMBSFEHF-!uif!TpmbsFehf!mphp-!PQUJNJ\[FE!CZ!TPMBSFEHF! bsf!usbefnbslt!ps!sfhjtufsfe!usbefnbslt!pg!TpmbsFehf!Ufdiopmphjft-!Jod/!Bmm!puifs!usbefnbslt!nfoujpofe!ifsfjo! bsf!usbefnbslt!pg!uifjs!sftqfdujwf!pxofst/!Ebuf;!1303128/!W/12/!Tvckfdu!up!dibohf!xjuipvu!opujdf/ ® Zilla Double Stud Flashing One or more patents apply to this product including without limitation: US Pat. 8,448,405; 8,707,654; 8,689,517; 8,707,655; and/or 8,752,338. ZDSFA-15 AL / ZDSFA-15 AL BLK ® Zilla Double Stud Flashing ® Double S (with washer and hex head) ® Flashing ® Two point installation la Base (fastening hardware not included) ® 1 Zilla Double Stud Flashing is available in Black (ZDSFA-15 AL BLK) or custom colors and includes: Double Stud with Encapsulated Gland Washer, Flashing and Base Plate. ® Zilla Double Stud is a 3/8”-16 x 1-1/2” stainless steel stud with 3/16” recessed hex and Mill 1 1-3/8” hex aluminum nut. ) PRODUCTDESCRIPTIONMATERIALSSIZECOLOR Provides mechanical connection directly to Base Aluminum / Plate through Flashing. 3/8”-16 SS hardware and 1-3/8” Hex x 1.5”Mill Double Stud SS encapsulated gland washer included. Black Sits on top of the Base Plate, and is captured by the 15” L x 9-7/8” W Aluminum Flashing Double Stud. 26 ga.x 1/2” H 1 Mill Base Plate is attached to the roof with lags. Galvanized 3-7/8” L x 3” W Flashing is attached to the Base Plate using the Mill Base Plate 2 Steelx 1/2” H Double Stud. Lags (2) 3/8” lags (two point installation).Zinc5/16” hex drive Zinc (not included) 3 (lb./in. of thread penetration) LUMBER SPECIFIC SPECIESGRAVITYSCREWSCREWSCREW 0.50252 lb./in.298 lb./in.342 lb./in. 0.55291 lb./in.344 lb./in.394 lb./in. 1 2 3 ® S M ZillaSo Simple It’s Scary 77 Waneka Pkwy • Lafayette, CO 80026 • 720.880.6700• fax 303.664.1268 • zillarac.com MADE IN USA MADE WITH RECYCLED MATERIAL © 2017 Zilla Corporation. All rights reserved. Whfk!Eulhi XR Rail Family Vrodu!Lv!Qrw!Dozd|v!Vxqq| Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Irufh0Vwdelol}lqj!Fxuyh Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Frpsdwleoh!zlwk!Iodw!)!Slwfkhg!UrrivFruurvlrq0Uhvlvwdqw!Pdwhuldov XR Rails are IronRidge offers All XR Rails are made of marine-grade Roof Mount utilizes XR compatible with a range of tilt leg aluminum alloy, then protected with an Rails, along with optional FlashFoot and all-in-one attachments, other pitched roof roof mounting and structural corrosion, while also providing attachments.applications.a more attractive appearance. against residential roofs. Whfk!Eulhi \[U!Udlo!Idplo| design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10XR100XR1000 XR100 is the ultimate residential XR1000 is a heavyweight among rail, designed for regions with light or mounting rail. It supports a range of solar mounting rails. It’s built to handle no snow. It achieves 6 foot spans, while wind and snow conditions, while also extreme climates and spans 12 feet or remaining light and economical.maximizing spans up to 8 feet.more for commercial applications. •6’ spanning capability•8’ spanning capability•12’ spanning capability •Moderate load capability•Heavy load capability•Extreme load capability ••• •Internal splices available•Internal splices available•Internal splices available Udlo!Vhohfwlrq The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Udlo!Vsdq Load Vqrz!+SVI,Zlqg!+PSK,4’8!7ܒ6’8’10’12’ 100 120 None 140 XR10XR100XR1000 160 100 120 10-20 140 160 100 30 160 100 40 160 50-70160 80-90160 !!5347!LurqUlgjh/!Lqf1!Doo!uljkwv!uhvhuyhg1!Ylvlw!zzz1lurqulgjh1frp!ru!fdoo!40;33055:0<856!iru!pruh!lqirupdwlrq1!Yhuvlrq!4144