Loading...
HomeMy WebLinkAboutPLAN CHANGES 537 Big Thompson Ave Starbucks 2017-11-21GENERAL NOTES 1. THESE DRAWINGS ARE INTENDED TO BE USED WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR COORDINATING SUCH REQUIREMENTS INTO THEIR SHOP DRAWINGS AND WORK. 2. NO OPENING SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. 3. NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. 4. OPENINGS IN SLAB OF 1'-4" AND LESS ON A SIDE ARE GENERALLY NOT SHOWN ON THE STRUCTURAL DRAWINGS. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SUCH OPENINGS. 5. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED UPON STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN CAPACITY OF THE FRAMING AT THE TIME THE LOADS ARE IMPOSED. 6. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES. 7. UNLESS OTHERWISE NOTED, FIREPROOFING METHODS AND MATERIALS FOR STRUCTURAL MEMBERS ARE NOT SHOWN ON STRUCTURAL DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR FIRE RATING REQUIREMENTS, FIRE PROOFING METHODS AND MATERIALS. 8. DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. 9. THE CONTRACTOR SHALL INFORM THE ARCHITECT/ENGINEER OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY THE ARCHITECT/ENGINEER'S APPROVAL OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS HE HAS SPECIFICALLY INFORMED THE ARCHITECT/ENGINEER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE ARCHITECT/ ENGINEER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION.10. ALL THINGS WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS, BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. PLANS AND/OR SPECIFICATIONS WILL BE CORRECTED, OR WRITTEN INTERPRETATION OF THE ALLEGED DEFICIENCY, OMISSION, CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE ARCHITECT/ENGINEER BEFORE THE AFFECTED WORK PROCEEDS. 12. SPECIAL INSPECTIONS ARE REQUIRED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE AND THE SPECIFICATIONS OF THIS PROJECT PER SPECIAL INSPECTION TABLE ON THIS SHEET. 11. CONTRACTOR TO NOTIFY APEX ENGINEERS, INC. AT LEAST 48 HOURS IN ADVANCE OF ANY CONCRETE POUR. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERRORS OR DETAILING, FABRICATION AND INSTALLATION. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS IN THE FIELD NECESSARY TO VERIFY OR SUPPLEMENT DIMENSIONS SHOWN ON THE CONTRACT DRAWINGS AND HE SHALL VERIFY THAT ALL DIMENSIONS SHOWN ON THE SHOP DRAWINGS ARE COORDINATED WITH THE DIMENSIONS AND REQUIREMENTS OF THE CONTRACT DRAWINGS. REVIEW OF THE SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OR RESPONSIBILITY FOR COMPLETING THE WORK SUCCESSFULLY IN ACCORDANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS. 14. SUBMIT PRINTS OR ELECTRONIC COPIES OF EACH SHOP DRAWINGS. REPRODUCIBLE COPIES OF CONTRACT DOCUMENTS SHALL NOT BE USED AS SHOP DRAWINGS. SHOP DRAWINGS SHALL BE REVIEWED BY CONTRACTOR PRIOR TO SUBMISSION. CONTRACTOR STAMP SHOP DRAWING ACCEPTING RESPONSIBILITY FOR COORDINATION OF DIMENSIONS SHOWN IN THE CONTRACT DOCUMENTS, QUANTITIES AND COORDINATION WITH OTHER TRADES. DRAWINGS NOT BEARING CONTRACTOR'S STAMP MAY BE REJECTED AT THE DISCRETION OF THE ARCHITECT OR STRUCTURAL ENGINEER. 15. REVIEW AND RETURN OF SHOP DRAWINGS SHALL BE BASED ON A MINIMUM OF TEN (10) WORKING DAYS IN THE STRUCTURAL ENGINEER'S OFFICE FROM RECEIPT OF SUBMISSION TO RETURN TO THE NEXT PARTY FOR THEIR ACTION. SHOP DRAWINGS SHOULD BE SUBMITTED INCREMENTALLY AS APPROPRIATE PACKAGES ARE PREPARED TO EQUALIZE THE WORKLOAD FOR REVIEW OF THE DRAWINGS. SUBMISSION OF A LARGE VOLUME OF SHOP DRAWINGS AT ONE TIME MAY RESULT IN REVIEW TIMES WHICH WILL EXCEED THOSE NOTED ABOVE. DEFINITION OF A "LARGE VOLUME" OF SHOP DRAWINGS IS SUBJECT TO INTERPRETATION. FOUNDATION NOTES 1. CONTRACTOR SHALL BE FULLY FAMILIAR WITH ALL ASPECTS OF THE SOILS REPORT BEFORE BEGINNING CONSTRUCTION. 2. CONTRACTOR SHALL USE THE SOILS REPORT FOR SPECIFICATIONS AND DETAILS FOR PLACEMENT OF PERIMETER DRAINS, UNDER-SLAB DRAINS, AND ANY OTHER SOILS RELATED ITEMS. 2. ALL FOUNDATIONS TO BEAR ON ORIGINAL, UNDISTURBED SOIL OR FILL COMPACTED AND TESTED TO CONFORM TO THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. 3. ALL FOOTING EXCAVATIONS TO BE APPROVED BY GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE. 4. ALL FOOTINGS SHALL EXTEND BELOW FROST DEPTH, REFER TO DESIGN INFORMATION STEEL NOTES 1. ALL STRUCTURAL STEEL TO BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES." 2. BOLTED CONNECTIONS: ALL BOLTED CONNECTIONS SHALL BE SNUG- TIGHT IN ACCORDANCE WITH THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" PUBLISHED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS. 3. WELDED CONNECTIONS: ALL WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL WELDING SOCIETY CODE" (AWS D1.1) PUBLISHED BY THE AMERICAN WELDING SOCIETY. ELECTRODES FOR WELDING SHALL COMPLY WITH THE REQUIREMENTS OF TABLE 3.1 OF (AWS D1.1). ALL WELDING TO BE DONE BY QUALIFIED WELDERS CONFORMING TO THE AMERICAN WELDING SOCIETY STANDARDS. 4. SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON THE DRAWINGS, IS PROHIBITED WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. 5. CHANGES IN SIZE OR POSITION OF THE STRUCTURAL ELEMENTS, AND HOLES, SLOTS, CUTS, ETC. THROUGH ANY MEMBER, ARE NOT PERMITTED UNLESS THEY ARE DETAILED ON THE APPROVED SHOP DRAWINGS. 6. NO FINAL BOLTING OR WELDING SHALL BE MADE UNTIL AS MUCH OF THE STRUCTURE AS WILL BE STIFFENED THEREBY HAS BEEN PROPERLY ALIGNED. 7. FABRICATE ALL BEAMS WITH THE MILL CAMBER UP U.N.O. 8. ALL COLUMN BASE PLATES SHALL BE SOLIDLY GROUTED WITH NON- SHRINK GROUT UNDER THE ENTIRE BASE PLATE AREA. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI @ 28 DAYS. 9. ALL VISIBLE WELDED CONNECTIONS ON ARCHITECTURAL ELEMENTS TO BE GROUND SMOOTH. DO NOT REDUCE THROAT SIZE OF WELD. 10. THE FABRICATOR SHALL BE RESPONSIBLE FOR THE DESIGN AND PERFORMANCE OF ALL CONNECTIONS NOT FULLY DESIGNED OR DETAILED ON THE CONTRACT DOCUMENTS. FABRICATOR IS TO FURNISH ARCHITECT/ ENGINEER WITH SHOP DRAWINGS FOR APPROVAL. 11. STEEL MEMBERS ON THE EXTERIOR OF THE BUILDING OR EXPOSED TO SOIL MUST BE, AT A MINIMUM, PROPERLY PRIMED WITH RUST INHIBITING PRIMER AND PAINTED. STEEL MEMBERS COMPLETELY ENCLOSED IN BUILDING ENVELOPE DO NOT REQUIRE PRIMER OR PAINT, U.N.O.. REFER TO ARCHITECTURAL DOCUMENTS FOR ADDITIONAL REQUIREMENTS OF EXPOSED STEEL. STEEL MEMBERS ASTM A992 HILTI KWIK BOLT III WIDE FLANGE SHAPES (W) CHANNELS (C), ANGLES (L) HOLLOW STRUCTURAL SHAPES (HSS) HIGH STRENGTH BOLTS EPOXY BOLTS ANCHOR BOLTS (HEX-HEAD U.N.O.) EXPANSION BOLTS ASTM A36 ASTM A500, GRADE B ASTM A325 ASTM A36 MATERIAL PLATES ASTM A36 STEEL MATERIAL SCHEDULE ASTM F1554 (36 ksi) PREFAB LIGHT GAUGE TRUSS NOTES 1. TRUSSES TO BE DESIGNED AND ERECTED IN CONFORMANCE WITH TRUSS PLATE INSTITUTE SPECIFICATIONS AND RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL BUILDING CODES. 2. TRUSSES TO BE BRACED PER MANUFACTURER'S RECOMMENDATIONS DURING ERECTION. 3. TRUSSES SHALL BE LATERALLY SUPPORTED AT ALL PANEL POINTS. 4. TRUSS MANUFACTURER IS TO SUBMIT LAYOUT PLANS AND CALCULATIONS FOR ALL TRUSSES. THE CALCULATIONS ARE TO BEAR A LICENSED PROFESSIONAL ENGINEER'S SEAL. CALCULATIONS ARE TO SHOW LOADINGS, SPACING, STRESSES, CONFIGURATION, CONNECTIONS, GRADE OF MATERIAL, CAMBER, AND DEFLECTIONS. TRUSS DESIGN LOADS TOP CHORD LIVE LOAD / SNOW LOAD DEAD LOAD BOTTOM CHORD DEAD LOAD 70 PSF 10 PSF 10 PSF PREFAB WOOD TRUSS NOTES 1. TRUSSES TO BE DESIGNED AND ERECTED IN CONFORMANCE WITH TRUSS PLATE INSTITUTE SPECIFICATIONS AND RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL BUILDING CODES. 2. TRUSSES TO BE BRACED DURING ERECTION. REFER TO BCSI: GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, RESTRAINING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES, 2008 EDITION. TRUSS DESIGN LOADS TOP CHORD LIVE LOAD / SNOW LOAD DEAD LOAD BOTTOM CHORD DEAD LOAD 3. TRUSS MANUFACTURER IS TO SUBMIT LAYOUT PLANS AND CALCULATIONS FOR ALL TRUSSES. THE CALCULATIONS ARE TO BEAR A LICENSED PROFESSIONAL ENGINEER'S SEAL. CALCULATIONS ARE TO SHOW LOADINGS, SPACING, STRESSES, CONFIGURATION, CONNECTIONS, GRADE OF MATERIAL, CAMBER, AND DEFLECTIONS. 30 PSF 10 PSF 10 PSF ROUGH CARPENTRY NOTES 1. CONTRACTOR IS RESPONSIBLE TO ADEQUATELY SHORE AND BRACE ALL FLOOR AND ROOF FRAMING AND WALLS DURING CONSTRUCTION. 2. NAILING: SHALL BE PER FASTENING SCHEDULE OF THE INTERNATIONAL BUILDING CODE. FOR PREFABRICATED CONNECTORS USE ALL FASTENERS AS PRESCRIBED BY THE MANUFACTURER. 3. ALL POST AND JAMBS ARE TO BE BLOCKED SOLID WITH THE SAME NUMBER OF PIECES AS THE POST OF JAMB WITHIN THE FLOOR SPACE. BLOCKING IS TO ALIGN WITH POST OR JAMBS. JOIST, RAFTERS, HEADERS, BEAMS STUDS, BEARING WALL 4. SPECIES AND GRADES SHOWN IN SCHEDULE ARE THE MINIMUM ACCEPTABLE. BETTER GRADES MAY BE SUBSTITUTED. 5. PRESSURE TREATED WOOD TO BE USED WHEN EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE OR MASONRY. 5/8" (NOMINAL) RATED 40/20. 3/4" (NOMINAL) RATED 48/24 T&G 6. WOOD STRUCTURAL PANELS TO BE A.P.A. RATED AND EXPOSURE 1. PANELS TO BE MANUFACTURED PER U.S. DEP. OF COMMERCE PRODUCT STANDARDS PS1 OR PS2. MICROLLAM TIMBERSTRAND BAND BOARD ASTM A307 (MIN.) WOOD MATERIAL SCHEDULE MEMBERS MATERIAL SPECIFICATION SILL AND TOP PLATES BOLTS AND THREADED RODS ROOF SHEATHING FLOOR SHEATHING TREATED LUMBER GLULAM BEAMS SINGLE SPAN MULTI SPAN No. 2 DF/L No. 1 DF/L HEM-FIR Fb = 2800 PSI E = 1.9 x 10 E6 PSI Fb = 1700 PSI E = 1.3 x 10 E6 PSI No. 2 So. Pine DF/DF 24F-V4 24F-V8 REBAR SCHEDULE DEVELOPMENT LENGTHS - Ld f'c = 3000 PSI f'c = 4000 PSI #4 #5 #6 #4 #5 #6 BAR SIZE STD. Ld CLASS B STD. Ld CLASS BBAR SIZETYP. TOP TYP. TOP TYP. TOP TYP. TOP 15" 28" 33" 13" 24" 29" 19" 36" 43" 17" 31" 37" 20" 37" 43" 25" 47" 56" 23" 41" 49" 17" 32" 38" STANDARD HOOKS f'c = 3000 PSI f'c = 4000 PSI #4 #5 #6 #4 #5 #6 BAR SIZE BAR SIZE 180 DEGREE HOOK 90 DEGREE HOOK Ldh Ldh Ldh Ldh 6" 9" 10" 6" 10" 12" A B CR I T I C A L SE C T I O N CR I T I C A L SE C T I O N CC HOOK DIMENSIONS HOOK DIMENSIONS "A" "B" "C" "A" "B" "C" 2 1/2" 2 1/2" 3" 2 1/2" 2 1/2" 3" 2" 2 1/2" 3" 2" 2 1/2" 3" 6" 7 1/2" 9" 6" 7 1/2" 9" USE THE ABOVE TABLE UNLESS NOTED OTHERWISE ON PLANS OR DETAILS DbDb MASONRY f'm = 1500 PSI #4 #5 #6 BAR SIZE Ldh 5 5/8" 7 1/8" 8 1/2" HOOK DIMENSIONS "A" "B" "C" 2 1/2" 2 1/2" 3" 2" 2 1/2" 3" 6" 7 1/2" 9" Ld 21" 26" 40" ASTM A615, GRADE 40 ASTM A185 TYPICAL REINFORCING STEEL SPECIFICATIONS (U.N.O.) REINFORCING STEEL #4 AND SMALLER #5 AND LARGER WELDED WIRE FABRIC STEEL SPECIFICATION ASTM A615, GRADE 60 13. PROVIDE CORNER BARS TO MATCH ALL HORIZONTAL BARS IN WALL. REFER TO TYP. DETAIL BELOW. Ld Ld Ld Ld: CLASS B TENSION SPLICE RE: SCHEDULE CONT. TOP AND BOTTOM BARS TYP. CORNER BAR DIAGRAM TYP. VERTICAL WALL CONTROL JOINT D/8CONTROL JOINT 14. PROVIDE VERTICAL CONTROL JOINTS ON ALL POURED CONCRETE WALLS AND BASEMENT WALLS. SPACE JOINTS AT 3 X WALL HEIGHT FOR WALLS LESS THAN 10 FT AND WALL HEIGHT FOR TALLER WALLS. D D/8COSTRUCTION JOINT STOP EVERY OTHER HORIZ. BAR AT JOINTSOIL SIDE WATER STOP AND BITUTHENE STRIP AT JOINT FORMED KEY WAY CONCRETE NOTES 1. ALL CONCRETE CONSTRUCTION TO CONFORM TO ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318-(MOST RECENT EDITION) AND ACI "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" ACI 301, UNLESS NOTED OTHERWISE. 2. SPECIAL INSPECTION AGENCY TO PERFORM TESTS AT SEVEN (7) DAYS AND AT TWENTY EIGHT (28) DAYS. A STRENGTH TEST SHALL BE THE AVERAGE OF THE STRENGTHS OF AT LEAST TWO (2) 6"x12" CYLINDERS OR AT LEAST THREE (3) 4"x8" CYLINDERS MADE FROM THE SAME SAMPLE OF CONCRETE. HOLD ONE ADDITIONAL CYLINDER IN RESERVE UNTIL PROJECT IS COMPLETED. TESTING LABORATORY IS TO FURNISH ARCHITECT/ENGINEER WITH TEST RESULTS PROMPTLY. A. ONCE EACH DAY A GIVEN CLASS IS PLACED, NOR LESS THAN B. ONCE FOR EACH 150 CUBIC YDS OF EACH CLASS PLACED EACH DAY. NOR LESS THAN C. ONCE FOR EACH 5000 SQ/FT OF SLAB WALL OR SURFACE AREA PLACED EACH DAY 3. UNLESS OTHERWISE SHOWN IN THE ARCHITECTURAL DRAWINGS, PROVIDE 3/4" CHAMFERS AT THE EDGES THAT ARE EXPOSED TO VIEW IN THE FINISHED STRUCTURE. 4. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW OPENINGS, DRIP SLOTS, REGLETS, MASONRY, ANCHORS, BRICK LEDGE ELEVATIONS AND FOR MISCELLANEOUS EMBEDDED PLATES, BOLTS, ANCHORS, ANGLES, ETC. 5. REFER TO ARCHITECTURAL DRAWINGS FOR CONCRETE FINISHES. WHERE FINISH IS NOT SPECIFIED, CONFORM TO REQUIREMENTS OF ACI 301.6. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR DRAINS, SLEEVES, OUTLET BOXES, CONDUIT, ANCHORS, ETC. THE VARIOUS TRADES ARE RESPONSIBLE FOR PLACING THEIR ITEMS. 7. REFER TO MECHANICAL DRAWINGS FOR HOUSEKEEPING PADS AND INERTIA BASES AT MECHANICAL EQUIPMENT. FREQUENCY OF TESTING IS TO BE IN ACCORDANCE WITH ACI 318: 8. ALL REINFORCING STEEL TO BE DETAILED IN ACCORDANCE WITH ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES." 9. REINFORCING SHALL BE CONTINUOUS WHEREVER POSSIBLE. SPLICES AND LAPS TO CONFORM TO ACI 318. REFER TO REBAR SCHEDULE. 11. DOWELS IN FOOTING, WALLS, AND DRILLED PIERS MUST BE IN POSITION BEFORE PLACING CONCRETE WHENEVER POSSIBLE. 12. PROVIDE (2) #5 BARS EACH SIDE OF OPENINGS 1'-0" OR LARGER IN SLABS AND WALLS UNLESS OTHERWISE CALLED FOR ON STRUCTURAL PLANS 10. PROVIDE 6" LAP AT ALL WELDED WIRE FABRIC JOINTS. 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. X X X X X 1. INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. A. APPLICATION OF PRESTRESSING FORCES. X X 2. INSPECTION OF REINFORCING STEEL WELDING: 3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR SD IS USED.4. INSPECTION OF ANCHOR INSTALLED IN HARDENED CONCRETE. 5. VERIFYING USE OF REQUIRED MIX DESIGN 6. AT THE TIME FRESH CONCRETE IS SAMPLED, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPORATURE OF THE CONCRETE. 7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. 8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. 9. INSPECTION OF PRESTRESSED CONCRETE: B. GROUTING OF BONDED PRESTRESSING TENDONS IN THE SEISMIC-FORCE-RESISTING SYSTEM. 10. ERECTION OF PRECAST CONCRETE MEMBERS. 11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POSTTENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORING. 12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. A. VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A 706. B. REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES AND BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL WALLS OF CONCRETE AND SHEAR REINFORCEMENT. C. SHEAR REINFORCING. D. OTHER REINFORCING STEEL. X X X X X X X X X X X X X X 1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS: 2. INSPECTION OF HIGH-STRENGTH BOLTING: B. MANUFACTURER’S CERTIFICATE OF COMPLIANCE REQUIRED. A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. X X A. SNUG-TIGHT JOINTS X B. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITH MATCHMARKING, TWIST-OFF BOLT OR DIRECT TENSION INDICATOR METHODS. X C. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITHOUT MATCHMARKING OR CALIBRATED WRENCH METHODS OF INSTALLATION. X 3. MATERIAL VERIFICATION OF STRUCTURAL STEEL AND COLD- FORMED STEEL DECK: A. FOR STRUCTURAL STEEL, IDENTIFICATION MARKINGS TO CONFORM TO AISC 360. B. FOR OTHER STEEL, IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVE CONSTRUCTION DOCUMENTS. C. MANUFACTURER’S CERTIFIED TEST REPORTS. X X X 4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS: A. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE APPROVED CONSTRUCTION DOCUMENTS. B. MANUFACTURER’S CERTIFICATE OF COMPLIANCE REQUIRED. X X 5. INSPECTION OF WELDING: A. COMPLETE AND PARTIAL JOINT PENETRATION GROOVE. B. MULTI-PASS FILLET WELDS. C. SINGLE-PASS FILLET WELDS > 5/16" D. PLUG AND SLOT WELDS. E. SINGLE-PASS FILLET WELDS <= 5/16" F. FLOOR AND ROOF DECK WELDS. X X X X X X X 6. INSPECTION OF STEEL FRAME JOINTS DETAILS AT EACH CONNECTION: A. DETAILS SUCH AS BRACING AND STIFFENING. B. MEMBER LOCATIONS C. APPLICATION OF JOINT DETAILS AT EACH CONNECTION. X X X CONSTRUCTION TYPE FREQUENCYCODE REFERENCE CONT. PER. STATEMENT OF SPECIAL INSPECTION STRUCTURAL STEEL1705.2 REINFORCED CONCRETE1705.3 SOILS1705.6 DESIGN INFORMATION SCHEDULE BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE AS ADOPTED AND/OR AMENDED BY LOCAL BUILDING CODES GROUND SNOW LOAD, Pg ROOF SNOW LOAD, Pr SNOW LOADING INFORMATION: 70 psf 70 psf SEISMIC DESIGN INFORMATION: SEISMIC RISK CATEGORY SITE CLASS (PER SOILS REPORT) SEISMIC RESISTING SYSTEM SPECTRAL RESPONSE COEFFICIENTS RESPONSE MODIFICATION, R DEFLECTION AMPLIFICATION FACTOR, Cd OVERSTRENGTH FACTOR, Ω SEISMIC RESPONSE COEFFICIENT, Cs SEISMIC DESIGN CATEGORY DESIGN SPECTRAL RESPONSE ACCELERATIONS SEISMIC ANALYSIS PROCEDURE SEISMIC BASE SHEAR, V 1.0kips D SD1 = 0.102 SDS = 0.227 Fv = 2.40 Fa = 1.60 Equivalent Pressure S1 = 0.064 Ss = 0.213 II A. Bearing Wall System Light Framed Sheathed Walls 6.50 4.00 3.00 0.035 B WIND DESIGN INFORMATION: WIND EXPOSURE CATEGORY OCCUPANCY CATEGORY VELOCITY PRESSURE, qz INTERNAL PRESSURE COEFFICIENT, GCpi DIRECTIONALITY FACTOR, Kd VELOCITY PRESSURE COEFFICIENT, Kh TOPOGRAPHICAL FACTOR, Kzt EDGE REGION, a COMPONENTS AND CLADDING LOADS WIND LOAD DIAGRAM 1 2 2 2 2 3 3 3 3 4 4 5 5 5 5 POSITIVE (+) NEGATIVE (-) "a" NOTES: 1. POSITIVE LOADS ACT INWARD AND DOWN. 2. NEGATIVE LOADS ACT OUTWARD AND UP. 3. LOADS ARE NOT FACTORED. MEAN ROOF HEIGHT / AVERAGE PARAPET LENGTH BUILDING LENGTH / BUILDING WIDTH C 0.85 56.6 psf BASIC WIND SPEED (3 SECOND GUST), V 175 mph +/-0.18 0.85 1.00 5' - 2" 57.1 psf 86.5 psf 133.5 psf 65.4 psf 75.4 psf 30.4 psf 30.4 psf 30.4 psf 59.7 psf 59.7 psf 13' - 0"/ 3' - 0" B=53' / L=57' ROOF ZONE 1 (AREA =50 SF) ROOF ZONE 2 (AREA =50 SF) ROOF ZONE 3 (AREA =50 SF) WALL ZONE 4 (AREA =50 SF) WALL ZONE 5 (AREA =50 SF) II SOILS ENGINEER REPORT NO. REPORT DATE SOILS INFORMATION: SOIL BEARING PRESSURE FROST DEPTH MIN. ISOLATED MIN. CONTINUOUS CTL THOMPSON FC07783-125 4/11/2017 MAX = 3000 psf 3' - 0" 1' - 6"1' - 4" LOADING INFORMATION:DEAD LOAD LIVE LOAD 20 psf 100 psf ROOF LOAD FLOOR LOAD 20 psf 75 psf SYMBOLS / ABBREVIATIONS X SX.X DETAIL ON SHEET SHEET NUMBER DETAILS, SECTIONS, & ELEVATIONS T = XXX' - XX" B = XXX' - XX" ELEVATION (TOP) ELEVATION (BOTTOM) FOOTINGS AND FOUNDATION WALLS SYMBOL/TA G DESCRIPTION APPLIES TO T.O.X. = XXX' - XX" ELEVATION MARK LEVELS, SPOT ELEVATIONS, & PLAN ELEVATIONS T.O.S. = XXX' - XX" TOP OF STEEL ELEVATION PLAN VIEW NOTATIONS X REVISION MARK SHEET REVISIONS ABV. DEFINITION ABV. DEFINITION A.B.ANCHOR BOLT APA AMERICAN PLYWOOD ASSOC. C.J. CONTROL JOINT C.L. DIA. EXT. GA. T.O.M. T.O.C. T.O.S. T.O.W. H.A.S. o.c. PDF SIM. STD. TYP. U.N.O. CENTER LINE DIAMETER EXTERIOR GAUGE HEADED ANCHOR STUDS ON CENTER POWDER DRIVEN FASTENERS SIMILAR CONDITION STANDARD TYPICAL CONDITION UNLESS NOTED OTHERWISE JST. BRG. = XXX' - XX" JOIST BEARING ELEVATION PLAN VIEW NOTATIONS TOP OF CONCRETE TOP OF MASONRY TOP OF STEEL TOP OF WALL W.P. WORK POINT T.O.D. TOP OF DECK E.O.D. E.O.S. EDGE OF DECK ANGLE EDGE OF SLAB P.A.F. POWDER ACTUATED FASTNR T.O.L. TOP OF LEDGE UNFORMED SURFACE IN CONTACT WITH THE GROUND FORMED SURFACES EXPOSED TO GROUND OR WEATHER WALLS AND SLABS NOT EXPOSED TO GROUND OR WEATHER INTERIOR BEAMS AND COLUMNS (TO TIES OF STIRRUPS) CONCRETE SCHEDULE CONCRETE USE 28 DAY STRENGT H W/C RATIO SLUMP LIMIT (in.) % AIR ENTRAINED CEMEN T TYPE 3" 1" 2" COVER 1 1/2" MINIMUM STRUCTURAL CONCRETE COVER REINFORCING BARS THREADED ROD ANCHORS EPOXY GROUTING APPLICATIONS 3000 psi 0.55 (MAX)N/A 3000 psi 0.55 (MAX)N/A FOUNDATION WALLS INTERIOR SLABS 4" (+/-1")3% MAX 4000 psi 0.50 (MAX)3" (+/-1")3% MAXN/A FOOTINGS/PIERS 5" (+/-1")3% MAX HILTI HIT-HY 200 A OR SIMPONS SET XP HILTI HIT-HY 200 R OR SIMPONS SET XP COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 2 8 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S1.0 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 GENERAL NOTES 11/21/2017 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT D 1 1 A A 3 B BC 2 E E 4 F F 51' - 9 3/4" 12 ' - 3 1 / 4 " 11 ' - 6 3 / 4 " 32 ' - 0 " 2' - 0 " 11 ' - 9 3 / 4 " 12 ' - 5 3 / 4 " 32 ' - 0 " 8' - 2 1 / 4 " 5 1/2"5' - 2" 2" 40' - 2 3/4" 2" 5' - 2"5 1/2" 5' - 2"41' - 5 3/4"5' - 2" 2 3/4"5' - 8 3/4"13' - 8 1/2"12' - 3"13' - 8 1/4" 9 3/4" 2 3/4" 26 ' - 3 1 / 4 " 29 ' - 6 3 / 4 " 2' - 0 " 25 ' - 9 3 / 4 " 30 ' - 5 3 / 4 " 8' - 2 1 / 4 " 8" 2' - 9 1 / 2 " 9' - 4 " 9' - 6 " 3' - 9 " 16 ' - 3 " 14 ' - 0 " BA S E P L A T E : 1 B/BP:9 9' - 5 1/ 2 " BA S E P L A T E : 1 B/BP:9 9' - 5 1/ 2 " BA S E P L A T E : 1 B/BP:9 9' - 5 1/ 2 " B A S E P L A T E : 1 B/B P:9 9' - 5 1/2" T.O.W. = 101' - 6" B.O.W. = 97' - 0" T.O.W. = 100' - 0" B.O.W. = 97' - 0" T.O.W. = 99' - 4" B.O.W. = 97' - 0" T.O.W. = 99' - 4" B.O.W. = 97' - 0"T.O.W. = 100' - 0" B.O.W. = 97' - 0" T.O.W. = 99' - 4" B.O.W. = 97' - 0" T.O.W. = 100' - 0" B.O.W. = 97' - 0" T.O.W. = 99' - 4" B.O.W. = 97' - 0" T.O.W. = 100' - 0" B.O.W. = 97' - 0" STEP T.O.W. BASE PLAT E : 3 B/ BP:100' - 1 1/2" STEP T.O.W. STEP T.O.W. STEP T.O.W. STEP T.O.W. STEP T.O.W. STEP T.O.W. T.O.W. = 100' - 0" B.O.W. = 97' - 0" 5 1/2"5' - 2"40' - 6 3/4"5' - 2"5 1/2" 51' - 9 3/4" 2 3/4" BASE PLAT E : 3 B/ BP:100' - 1 1/2" BASE PLAT E : 3 B/ BP:100' - 1 1/2" 1 S4.0 2 S4.0 1 S4.1 2 S4.1 1 S4.2 2 S4.2 3 S4.2 3 S4.3 1 S4.3 2 S4.3 1 S4.4 3 S4.0 BA S E P L A T E : 2 B/BP:9 9' - 6 1/ 2 " 5 8" 13 ' - 2 5 / 8 " 8' - 6 " 19 ' - 1 1 " 14 ' - 0 " BASE PLAT E : 2 B/ BP:100' - 1 1/2" B A S E P L A T E : 2 B/B P:1 0 0' - 1 1/2" CROSS HATCHING INDICATES AREA OF SLAB TO BE RECESSED FOR ENTRY MATS. RE: ARCH FOR RECESS DISTANCE (TYP.) 5' - 2"20' - 10 1/4"19' - 2 1/2"6' - 7" T.O.F.=97' - 0" B.O.F.=96' - 0"B T.O.F.=97' - 0" B.O.F.=96' - 0"C T.O.F.=97' - 0" B.O.F.=96' - 0"C T.O.F.=97' - 0" B.O.F.=96' - 0"B T.O.F.=97' - 0" B.O.F.=96' - 0"C T.O.F.=97' - 0" B.O.F.=96' - 0"C T.O.F.=97' - 0" B.O.F.=96' - 0"B T.O.F.=97' - 0" B.O.F.=96' - 0"A T.O.F.=97' - 0" B.O.F.=96' - 0"A T.O.F.=97' - 0" B.O.F.=96' - 0"A T.O.F.=97' - 0" B.O.F.=96' - 0"A T.O.W. = 100' - 9" B.O.W. = 97' - 0" B A S E P L A T E : 2 B/B P:1 0 0' - 1 1/2" 2 3/4" T.O.F.=97' - 0" B.O.F.=96' - 0"D B A S E P L A T E : 2 B/B P:1 0 0' - 1 0 1/2" T.O.F.=97' - 0" B.O.F.=96' - 0"D ANCHOR BOLT SCHEDULE HEX-HEAD BOLTS POST INSTALLED EM B E D 4"4" EM B E D 7" 9" 12" 15" 18" 3 1/2" 5" 6" 8" 8" NOTE: PROVIDE 3" COVER BELOW ANCHOR BOLT. REDUCE EMBED FOR ANCHOR BOLTS IN PAD FOOTINGS WITH DEPTH LESS THAN ANCHOR BOLT EMBED + 3" CLEAR COVER. BOLT DIAMETER ANCHOR BOLT EMBEDHEX-HEAD POST INSTALLED 1/2" 5/8" 3/4" 7/8" 1" BASE PLATE SCHEDULE 1" 1 1/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3" 1 1 / 2 " SHAPE A 4 1/2" 1 1 / 2 " SHAPE B 1 1/2" 1 1/2" 1 1/2" 1/4" 1 1 / 2 " SHAPE C 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1 / 2 " SHAPE D 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 1/4"BASE PLATE: 1B/BP:100' -1 1/2"BASE PLATE CALLOUT BOTTOM OF BASE PLATE ELEVATIONPLAN COLUMN CENTERLINES OF COLUMN GRID/DIMENSION LINESPLATE SHOWN FOR ORIENTATION BASE PLATE TAG NOTES: 1. PROVIDE 5/16" FILLET WELD AT COLUMN TO BASE PLATE CONNECTION. PLATE TYPE 1 SHAPE 2 3 4 A B C D PLATE THICKNESS ANCHOR BOLT SIZE 3/16" = 1'-0" FOUNDATION WALL PLAN FOUNDATION PLAN NOTES 4. CONTRACTOR TO FIELD VERIFY ALL FOUNDATION ELEVATIONS & STEP FOUNDATION PER SITE CONDITIONS. 6. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, EXTERIOR FINISHES AND ADDITIONAL NOTES. SLAB JOINT DIAGRAM (COLD JOINT) (CONTROL JOINT) SAW-CUT 1/4 SLAB DEPTH #4x24" SMOOTH DOWEL at 24"o.c. BOND BREAKER (ONE SIDE) 1. FLOOR CONSTRUCTION: 5" CONCRETE SLAB-ON-GRADE REINFORCED WITH #3 AT 18" EA. WAY OR6x6 W2.1xW2.1 WWF ON 10 MIL. VAPOR BARRIER ON MIN. 4" OF 3/4" CLEAN, GRADED ROCK. 2. TOP OF SLAB ELEVATION = 100' - 0" (REFERENCE ONLY) 5. ALL DIMENSIONS SHOWN ARE TAKEN FROM GRID LINES. 3. CONTROL JOINTS (1/4 SLAB DEPTH) AT 10' - 0" MAX, BOTH WAYS (NOT SHOWN FOR CLARITY, REFERENCE TYPICAL DETAILS BELOW. 7. SEE SHEET S1.0 FOR ADDITIONAL STRUCTURAL SPECIFICATIONS. COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 2 8 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S2.0 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 FOUNDATION WALL PLAN 11/21/2017 PAD FOOTING SCHEDULE MARK # LENGTH WIDTH D REINFORCING DOWELS A 4 2' - 3" 2' - 3" 12" (4) #4 EA. WAY #5 at 32"o.c. B 3 3' - 0" 3' - 0" 12" (4) #5EA. WAY #5 at 32"o.c. C 4 4' - 0" 4' - 0" 12" (5) #5 EA. WAY #5 at 32"o.c. D 2 5' - 0" 5' - 0" 12" (6) #5 EA. WAY #5 at 32"o.c. Grand total: 13 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT D 1 1 A A 3 B BC 2 (3 ) 1 3 / 4 " x 1 1 1 / 4 " L . V . L . GI R D E R T R U S S GIRDER TRUSS GI R D E R T R U S S(3) 2X6(3) 2X6(3) 2X6HSS6 X6X 3 /8 HSS6 X6X 3 /8 HSS6 X6X3 /8 PRE-ENG. JACK TRUSSES at 24"o.c. 2x8 at 12"o.c.2x8 at 12"o.c. HSS5 X5X3 /8 9/ S5.0 PRE-ENGINEERED ROOF TRUSSES at 24"o.c. E E 4 F F(3) 2X6(3) 2X6PRE-ENGINEERED ROOF TRUSSES at 24"o.c. PRE-ENGINEERED ROOF TRUSSES at 24"o.c. PRE-ENG. JACK TRUSSES at 24"o.c. PROVIDE SIMPSON H2.5A SEISMIC ANCHORS AT EACH TRUSS BEARING LOCATION PROVIDE SIMPSON H2.5A SEISMIC ANCHORS AT EACH JOIST BEARING LOCATION 50' - 10 3/4" 5' - 2" 2" 40' - 2 3/4" 2" 5' - 2" 4"13' - 8 1/2"12' - 3"13' - 8 1/4" 7" 2 3/4" 32 ' - 0 " 11 ' - 6 3 / 4 " 11 ' - 4 " 3" 2 3 / 4 " 29 ' - 6 3 / 4 " 25 ' - 7 " 50' - 10 3/4" 5' - 2"40' - 6 3/4"5' - 2" 2 3/4" 2 3 / 4 " 3' - 9 " 9' - 6 1 / 4 " 9' - 3 3 / 4 " 2' - 9 1 / 4 " ATTACHMENT PANEL EDGE NAILING ALL OTHER EDGES PANELS 5/8" APA RATED SHEATHING, EXPOSURE 1, ID No.40/20. 10d NAILS 6"o.c. 12"o.c. WOOD ROOF DECK HSS 6X2X3/16 at 24"o.c. HSS6 X6X 3 /8 S3.0 1 FRAME 1 ELEVATION HSS5 X5X3 /8 8/ S5.0 HSS5 X5X3 /8 9/ S5.0 1 S4.0 2 S4.0 1 S4.1 2 S4.1 1 S4.2 2 S4.2 3 S4.2 3 S4.3 1 S4.3 2 S4.3 1 S4.4 3 S4.0 H S S 5 X 5 X 3/8 HSS5 X5X3 /8 9/ S5.0 3/8" FIN PLATES at 24"o.c. HSS 7X5X1/2(3) 2X6(2) T(2) K(2) T(2) KH S S 5 X 3 X 1/2 9/S 5.0 HS S 9 X 5 X 1 / 2 HSS 9X5X1/2 (2 SPAN CONT.) 3/8" FIN PLATES at 24"o.c. 3/8" FIN PLATES at 24"o.c. 5 (3) 1 3/4"x11 7/8" L.V.L. (2 SPAN CONT.) AT HATCHING SPACE ROOF SHEATHING NAILING at 4"o.c. AT PANEL EDGES SW-1 SW-1 SW-2 SHADING INDICATES WOOD FRAMED WOOD SHEAR WALLS (TYP.) INDICATES SHEARWALL TYPE. RE: SHEET S5.1 (TYP.) HSS5 X5X 3 /8 7/S5.0 AT HATCHING SPACE ROOF SHEATHING NAILING at 4"o.c. AT PANEL EDGES HSS5 X5X 3 /8 7/S5.0 PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN TRUSSES IN-LINE WITH SHEARWALL PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN TRUSSES IN-LINE WITH SHEARWALL 1 AB GI R D E R T R U S S GIRDER TRUSS GI R D E R T R U S S(3) 2X6(3) 2X6(3) 2X6PRE-ENG. JACK TRUSSES at 24"o.c. 2x8 at 16"o.c. 2x8 at 16"o.c. (2) 1 3/4"x7 1/4" L.V.L. EF ATTACHMENT PANEL EDGE NAILING ALL OTHER EDGES PANELS 3/4" T&G APA RATED STURD-I-FLOOR, EXT. GRADE, ID No. 24/4810d NAILS AND SUBFLOOR CONSTSTRUCTION ADHESIVE 6"o.c. 10"o.c. WOOD FLOOR DECK 2 S4.1 1 S4.2 2 S4.2 3 S4.2 (4) 1 3/4"x7 1/4" L.V.L. AC 355lbs AC 355lbs TRUSS SUPPLIER TO PROVIDE OPENINGS IN TRUSS WEBS TO ALLOW MECH. DUCTS TO PASS THROUGH RE: MECH. DRAWINGS FOR SIZES AND ELEVATIONS TYPICAL 7 S5.0 3/16" = 1'-0" ROOF FRAMING PLAN COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 2 9 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S2.1 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 ROOF FRAMING PLAN 11/21/2017 3/16" = 1'-0" MECH. MEZZANINE FRAMING PLAN 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" BE 7"13' - 8 1/4"12' - 3"13' - 8 1/2"4" HS S 6 X 6 X 3 / 8 HS S 6 X 6 X 3 / 8 HS S 6 X 6 X 3 / 8 HS S 6 X 6 X 3 / 8 HSS7X5X3/8 HSS7X5X3/8 HSS7X5X3/8 HSS7X5X3/8 HSS7X5X3/8 HSS7X5X3/8 H S S 8 X 6 X3 /8 HSS 6X2X3/16 at 24"o.c. (MAX.) 7' - 8 1 / 4 " 2' - 3 1 / 2 " 4' - 1 0 3 / 4 " 8' - 5 1 / 2 " S5.0 1 S5.0 2 S5.0 3 S5.0 3TYP.TYP.S5.0 4 S5.0 4TYP.TYP.S5.0 5 S5.0 6TYP.2' - 3 3 / 4 " 1 1 / 4 " 5' - 3 1 / 4 " COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 0 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S3.0 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 FRAME ELEVATIONS 11/21/2017 1/2" = 1'-0" FRAME 1 ELEVATION 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" E 1' - 4" 4"8"4" 10 " 3" 2" 8" 2" HE E L H E I G H T RE : A R C H . F O R 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED ROOF TRUSSES at 24"o.c. SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES TRUSS SUPPLIER TO PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 1/2" APA WALL SHEATHING RE: PLAN FOR HEADER RE: ARCH. FOR STOREFRONT CONCRETE SLAB ON GRADE # 5 X at 24"o.c.2' -0" 2'-0" (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.2' -9" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 2X6 at 12"o.c. STUDWALL 1 1/2" T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" DF CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.3' -0" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 1' - 4" 4"8"4" 10 " 3" 2" 1/2" EXP. JT. MAT'L 5/8" APA RATED ROOF SHEATHING SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES PROVIDE FULL DEPTH 2x BLOCKING BETWEEN JOISTS PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 2X6 at 12"o.c. STUD WALL 1 1/2" PRE-ENGINEERED GIRDER TRUSS 1/4" 3 1/2" 1/4" 3 1/2" 3/16" 3/16" 3/8" FIN PLATE at 16"o.c. L 2X2X1/4 AROUND PERIMETER OF AWNING RE: ARCH. FOR GUTTER 3 1 / 2 " 2 3 / 4 " 2"2' - 10" (2) 2X6 TOP PLATES ATTACHED TO HSS TUBE WITH 1/2" THREADED RODS WELDED TO HSS TUBE at 32"o.c. (2) 2X6 BOTTOM PLATES ATTACHED TO HSS TUBE WITH 1/2" THREADED RODS WELDED TO HSS TUBE at 32"o.c. HSS 7X5X1/2 TUBE STEEL HEADER 3/8" CONT. STEEL PLATE RE: ARCH. FOR SLOPE PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN TRUSSES IN-LINE WITH SHEARWALL HE E L H E I G H T RE : A R C H . F O R T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" DF CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.3' -0" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 1' - 4" 4"8"4" 10 " 3" 2" 1/2" EXP. JT. MAT'L SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 2X6 at 12"o.c. STUD WALL 1 1/2" 1/4" 3 1/2" 1/4" 3 1/2" 3/16" 3/16" 3/8" FIN PLATE at 24"o.c. L 2X2X1/4 AROUND PERIMETER OF AWNING RE: ARCH. FOR GUTTER 3 1 / 2 " 2 3 / 4 " 2"2' - 10" (2) 2X6 TOP PLATES ATTACHED TO HSS TUBE WITH 1/2" THREADED RODS WELDED TO HSS TUBE at 32"o.c. (2) 2X6 BOTTOM PLATES ATTACHED TO HSS TUBE WITH 1/2" THREADED RODS WELDED TO HSS TUBE at 32"o.c. HSS 7X5X1/2 TUBE STEEL HEADER (2) 2X6 PLATES BELOW WINDOW WITH SIMPSON L70 FRAMING ANGLE EACH END TO TRIMMER AND KING STUDS (3) 2X8 HEADER RE: ARCH. FOR WINDOW 3/8" CONT. PLATE 5/8" APA RATED ROOF SHEATHING PROVIDE FULL DEPTH 2x BLOCKING BETWEEN JOISTS PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING PRE-ENGINEERED GIRDER TRUSS PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN TRUSSES IN-LINE WITH SHEARWALL COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 1 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S4.0 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 WALL SECTIONS 11/21/2017 3/4" = 1'-0"S4.0 WALL SECTION1 3/4" = 1'-0"S4.0 WALL SECTION2 3/4" = 1'-0"S4.0 WALL SECTION3 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" E CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.3' -0" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 1/2" EXP. JT. MAT'L 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED ROOF TRUSSES at 24"o.c. SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES TRUSS SUPPLIER TO PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 2X6 at 12"o.c. STUDWALL 2" 1 1/2" 1' - 4" 4"8"4" 10 " 3" HE E L H E I G H T RE : A R C H . F O R T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" E T.O.W.=100'-9" CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM # 5 X at 24"o.c.3' -0" 6" 1/2" EXP. JT. MAT'L 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED JACK TRUSSES at 24"o.c. SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES TRUSS SUPPLIER TO PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 2X6 at 12"o.c. STUDWALL TRUSS TO TRUSS CONNECTION BY TRUSS SUPPLIER PRE-ENGINEERED GIRDER TRUSS SIMPSON LSSU28 JOIST HANGER 2X8 at 24"o.c. 2X8 at 16"o.c. 3/4" APA RATED FLOOR SHEATHING (3) # 5 CONT. LONG # 5 at 16"o.c. TRANS # 5 at 16"o.c. EACH WAY 2' - 4" 10"8"10" 10 " 3" 2" FINISH GRADE. RE: ARCH/CIVIL 1 1/2" HE E L H E I G H T RE : A R C H . F O R COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 2 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S4.1 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 WALL SECTIONS 11/21/2017 3/4" = 1'-0"S4.1 WALL SECTION1 3/4" = 1'-0"S4.1 WALL SECTION2 1 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" E T.O.W.=101'-6" CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (3) # 5 CONT. LONG # 5 X at 24"o.c.3' -0" 10" 1/2" EXP. JT. MAT'L 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED JACK TRUSSES at 24"o.c. SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES TRUSS SUPPLIER TO PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 2X6 at 12"o.c. STUDWALL TRUSS TO TRUSS CONNECTION BY TRUSS SUPPLIER PRE-ENGINEERED GIRDER TRUSS SIMPSON LSSU28 JOIST HANGER 2X8 at 24"o.c. 2X8 at 16"o.c. 3/4" APA RATED FLOOR SHEATHING # 5 at 16"o.c. TRANS # 5 at 16"o.c. EACH WAY FINISH GRADE. RE: ARCH/CIVIL 2' - 4" 10"8"10" 10 " 3" 2" 1 1/2" HE E L H E I G H T RE : A R C H . F O R T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" 1 T.O.W.=101'-6" CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (3) # 5 CONT. LONG # 5 X at 24"o.c.3' -0" 10" 1/2" EXP. JT. MAT'L 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 5/8" APA RATED ROOF SHEATHING (2) 2X6 TOP PLATES 2X6 at 12"o.c. STUDWALL # 5 at 16"o.c. TRANS # 5 at 16"o.c. EACH WAY FINISH GRADE. RE: ARCH/CIVIL T.O.PLATE=SLOPES 2' - 4" 10"8"10" 10 " 3" 2" 2x BLOCKING BETWEEN TOP AND BOTTOM CHORDS OF PRE-ENGINEERED ROOF TRUSSES WITH SIMPSON LUS24 JOIST HANGER EACH END FIRST (3) JOIST SPACES at 48"o.c. PRE-ENGINEERED ROOF TRUSSES at 24"o.c. 2X6 BOTTOM PLATE ATTAHED TO (2) 2X6 TOP PLATE WITH 1/2" THRU-BOLTS at 32"o.c. STAGGERED SIDE TO SIDE CONT. 2X12 LEDGER ATTACHED WITH (4) 1/4"X5" TIMBER-LOK SCREWS at 16"o.c. OVER JOINT IN WALL FRAMING CONT. 2X8 LEDGER ATTACHED WITH (3) 1/4"X5" TIMBER-LOK SCREWS at 16"o.c. 2X6 at 16"o.c. STUDWALL T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" 1 T.O.W.=101'-6" 5/8" APA RATED ROOF SHEATHING CONCRETE SLAB ON GRADE (3) # 5 CONT. LONG 1/2" EXP. JT. MAT'L CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. 2X6 at 12"o.c. STUDWALL # 5 at 16"o.c. TRANS # 5 at 16"o.c. EACH WAY EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L (2) # 5 CONT. TOP AND BOTTOM # 5 X at 24"o.c.3' -0" 10" (2) 2X6 TOP PLATES 2x8 BLOCKING BETWEEN PLATEFORM FRAMING WITH SIMPSON LUS24 JOIST HANGER EACH END FIRST (3) JOIST SPACES at 48"o.c. 2X8 JOISTS at 16"o.c. 2X6 BOTTOM PLATE ATTAHED TO (2) 2X6 TOP PLATE WITH 1/2" THRU-BOLTS at 32"o.c. STAGGERED SIDE TO SIDE CONT. 2X12 LEDGER ATTACHED WITH (4) 1/4"X5" TIMBER-LOK SCREWS at 16"o.c. OVER JOINT IN WALL FRAMING CONT. 2X8 LEDGER ATTACHED WITH (3) 1/4"X5" TIMBER-LOK SCREWS at 16"o.c. 2X6 at 16"o.c. STUDWALL 2X8 JOISTS at 12"o.c. 2x8 BLOCKING BETWEEN ROOF JOIST FRAMING WITH SIMPSON LUS24 JOIST HANGER EACH END FIRST (3) JOIST SPACES at 48"o.c. 2' - 4" 10"8"10" 10 " 3" 2" 1 1/2" COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 5 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S4.2 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 WALL SECTIONS 11/21/2017 3/4" = 1'-0"S4.2 WALL SECTION1 3/4" = 1'-0"S4.2 WALL SECTION2 3/4" = 1'-0"S4.2 WALL SECTION3 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" A B CONCRETE SLAB ON GRADE (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.3' -0" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 1/2" EXP. JT. MAT'L SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 1/2" APA WALL SHEATHING CONT. 2X6 TREATED PLATE WITH 5/8" ANCHOR BOLTS at 32"o.c. ADHERED STONE VENEER. RE: ARCH. 2X6 at 12"o.c. STUD WALL 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED ROOF TRUSSES at 24"o.c. TRUSSES TO BE TOP CHORD BEARING AT STEEL BEAM 1' - 4" 10 " 3" 2" 4"8"4" 1 1/2" PROVIDE FULL DEPTH 2x BLOCKING BETWEEN JOISTS PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING PROVIDE FULL DEPTH SOLID BLOCKING BETWEEN TRUSSES IN-LINE WITH SHEARWALL HE E L H E I G H T RE : A R C H . F O R T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" B 5/8" APA RATED ROOF SHEATHING PRE-ENGINEERED ROOF TRUSSES at 24"o.c. SIMPSON H2.5A SEISMIC ANCHOR AT EACH TRUSS BEARING LOCATION SIMPSON L70 FRAMING ANGLE at 24"o.c. (2) 2X6 TOP PLATES TRUSS SUPPLIER TO PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES PROVIDE PANEL EDGE NAILING AT TRUSS BLOCKING 1/2" APA WALL SHEATHING RE: ARCH. FOR STOREFRONT CONCRETE SLAB ON GRADE # 5 X at 24"o.c.2' -0" 2'-0" (2) # 5 CONT. TOP AND BOTTOM (2) # 5 CONT. # 5 X at 24"o.c.2' -9" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 2X6 at 12"o.c. STUDWALL 1' - 4" 4"8"4" 10 " 3" 2" 1 1/2" 2" 8" 1/4" 3 1/2" 1/4" 3 1/2" 3/16" 3/16" 2 3 / 4 " 2"2' - 10" (2) 2X6 BOTTOM PLATES ATTACHED TO HSS TUBE WITH 1/2" THREADED RODS WELDED TO TOP OF HSS TUBE at 32"o.c. HSS 9X5X1/2 TUBE STEEL HEADER 3/8" FIN PLATE at 16"o.c. L 2X2X1/4 AROUND PERIMETER OF AWNING RE: ARCH. FOR GUTTER 3/8" CONT. STEEL PLATE RE: ARCH. FOR SLOPE 3 1 / 2 " 1/2" PLYWOOD SPACER HE E L H E I G H T RE : A R C H . F O R T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" CONCRETE SLAB ON GRADE # 5 X at 24"o.c.2' -0" 2'-0" (3) # 5 CONT. TOP AND BOTTOM # 5 X at 24"o.c.2' -9" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L 2" 8" 2" 2' - 2 1/2" HSS 6X6X3/8 S5.0 3 S5.0 3 S5.0 6 CONT. C 6X8.2 1/4" 3 1/2" 1/4" 3 1/2" 3/16" 3/16" 3/8" FIN PLATE at 16"o.c. RE: ARCH. FOR GUTTER 3/8" CONT. STEEL PLATE RE: ARCH. FOR SLOPE 3" 3 1 / 2 " 1/2" HSS 6X2X3/16 PURLINS at 24"o.c. 2X4 PLATE ATTACHED TO TOP OF PURLINES WITH 0.154" DIA. P.A.F. at 3"o.c. S5.0 2 PRE-ENGINEERED ROOF TRUSSES at 24"o.c. HSS 6X2X3/16 FASCIA 1/4" TYP. EA. END HSS 7X5X3/8 HSS 7X5X3/8 HSS 8X6X3/8 5 5/8" APA RATED ROOF SHEATHING 2X6 CONT. PLATE ATTACHED TO TOP OF TUBE WITH 0.154" P.A.F. at 6"o.c. STAGGERED SIDE TO SIDE PROVIDE PANEL EDGE NAILING AT PLATE ATTACHED TO TUBE STEEL FRAME 2x BLOCKING BETWEEN TOP CHORD OF PRE-ENGINEERED ROOF TRUSSES WITH SIMPSON LUS24 JOIST HANGER EACH END FIRST (3) JOIST SPACES at 48"o.c. CONT. 2X10 LEDGER ATTACHED TO HSS TUBE WITH 0.154" DIA P.A.F. at 12"o.c. STAGGERED TOP TO BOTTOM 1' - 0 " 4' - 0" 1' - 4"1' - 4"1' - 4" 3" COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 6 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S4.3 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 WALL SECTIONS 11/21/2017 3/4" = 1'-0"S4.3 WALL SECTION1 3/4" = 1'-0"S4.3 WALL SECTION2 3/4" = 1'-0"S4.3 WALL SECTION3 1 1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT T.O.W.=100'-0" T.O.PLATE=112'-10" T.O.F.=97'-0" CONCRETE SLAB ON GRADE # 5 X at 24"o.c.2' -0" 2'-0" (3) # 5 CONT. TOP AND BOTTOM (3) # 5 CONT. # 5 X at 24"o.c.2' -9" 6" EXT. PAVING. RE: ARCH. 1/2" EXP. JT. MAT'L CONT. C 6X8.2 1/4" 3 1/2" 1/4" 3 1/2" 3/16" 3/16" 3/8" FIN PLATE at 16"o.c. RE: ARCH. FOR GUTTER 3/8" CONT. STEEL PLATE RE: ARCH. FOR SLOPE 3" HSS 6X2X3/16 PURLINS at 24"o.c. 2X4 PLATE ATTACHED TO TOP OF PURLINES WITH 0.154" DIA. P.A.F. at 3"o.c. 5/8" APA RATED ROOF SHEATHING 2X6 CONT. PLATE ATTACHED TO TOP OF TUBE WITH 0.154" P.A.F. at 6"o.c. STAGGERED SIDE TO SIDE PRE-ENGINEERED ROOF TRUSSES at 24"o.c. HSS 6X2X3/16 FASCIA 1/4" TYP. EA. END HSS 7X5X3/8 HSS 7X5X3/8 2' - 0" 4"1' - 4"4" 8" 2" 10 " 3" 2" 1 1/2" 5 PROVIDE PANEL EDGE NAILING AT PLATE ATTACHED TO TUBE STEEL FRAME 2x BLOCKING BETWEEN TOP CHORD OF PRE-ENGINEERED ROOF TRUSSES WITH SIMPSON LUS24 JOIST HANGER EACH END FIRST (3) JOIST SPACES at 48"o.c. CONT. 2X10 LEDGER ATTACHED TO HSS TUBE WITH 0.154" DIA P.A.F. at 12"o.c. STAGGERED TOP TO BOTTOM COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 6 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S4.4 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 WALL SECTIONS 11/21/2017 3/4" = 1'-0"S4.4 WALL SECTION1 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT 36 " M A X 5' - 0 " (6) #5 FULL HEIGHT BARS WITH #3 TIES AT 10"o.c. WITH (3) AT TOP DIAMETER 1' - 6" REFER TO LIGHT POLL DRAWINGS FOR BASE PLATE AND ANCHOR BOLT LAYOUT. 3' - 0 " 1' - 0 " T.O.W.=RE: PLAN T.O.M.=RE: PLAN 8' - 0 " M A X 8" CMU WALL WITH # 6 at 24"o.c. VERT IN GROUTED CELLS AND STD WT. DUR-O-WAL at 16"o.c. HORIZ. #6x6'-0" DOWELS 2'-6" INTO FDN. WALL MATCH WALL REINF. SPACING 3" 3' - 8 " 10" #5x AT 12"o.c. ALT. HOOK (2) #5 CONT. TOP AND BOTTOM #4 AT 16"o.c. TRANS (4) #5 CONT. LONG. EXTERIOR SLAB ON GRADE BY OTHER (2) #5 CONT. BOND BEAM 1' - 2"8"1' - 2" 3' - 0" BENT PLATE 5X5X3/8 x 0'-5 1/2" EACH SIDE OPTIONAL: GUIDE STUDS AND MATCHING HOLES IN BEAM. TUBE STEEL COLUMN TUBE STEEL BEAM 1/4" 5 1/2" 1/4" 5" 1/4" 5" L6x4x3/8x0'-6" SEAT ANGLE TUBE STEEL COLUMN TUBE STEEL BEAM 5/16" 4" 5/16" 6" 5/16" 6" 1/2" MAX L3x3x1/4x0'-4" CLIP ANGLE VERTICAL REACTION CAPACITY 18 KIPS (ASD) ASSUMED REQ. BEARING LENGTH = 1/2" 3/16" 3/16" 3/16" GL 1' - 3" 1' - 3 " (8) #5x2'-6" DOWELS WELDED TO EMBED PLATE; WELD SHOULD DEVELOP 1.5 REBAR YEILD STRENGTH. 3/4" A325 THRU BOLTS TACK WELD TO UNDER SIDE OF EMBED PLATE. MATCH BASE PLATE ANCHOR BOLT PATTERN WELD TO EMBED PLATE. PROVIDE OVERSIZED HOLES IN BASE PLATE AND 1/4" WASHER PLATES. TUBE COLUMN REFERENCE PLAN SHEET 3/4" EMBED PLATE 3/16" VERTICAL TENSION CAPACITY 100 KIPS (LRFD) ISO VIEW 1 1/2" SHIM AND GROUT BENT PLATE 3/8"X6"X6" x 0'-5 1/2" OPTIONAL: GUIDE STUDS AND MATCHING HOLES IN BEAM. TUBE STEEL COLUMN TUBE STEEL BEAM 1/4" 5 1/2" 1/4" 5" 1/4" 5" 1/4" 5 1/2" 1/4" 18" 1/4" 18" STEEL PLATE 3/8"X6" X 1'-6" L 6x6x3/8x0'-5" SEAT ANGLE TUBE STEEL COLUMN TUBE STEEL BEAM 5/16" 4" 5/16" 6" 5/16" 6" 1/2" MAX L 6X6X3/8x0'-6" CLIP ANGLE VERTICAL REACTION CAPACITY 18 KIPS (ASD) ASSUMED REQ. BEARING LENGTH = 1/2" 3/16" 3/16" 3/16" 3/16" 5/16" 6" 5/16" 6" HSS 6X2X3/16 PURLINS at 24"o.c. 3/16" TYP. HSS 8x6x3/8 (TYP.) 3/16" 3/16" FULL PEN TUBE COLUMN REFERENCE PLAN SHEET STEEL TUBE BEAM REFERENCE PLAN SHEET L 4X4X3/8 X 0'-4 1/2" EACH SIDE OF COLUMN 1/4" (3) SIDES 1/4" (3) SIDES TUBE STEEL COLUMN REFERENCE PLAN SHEET 1 1/2" 2 1/2"2"2" 2 1/2" 1 1/2" 1/2" CAP PLATE WITH (4) 1/2" THRU-BOLTS TO CONT. (2) 2X6 TOP PLATE AT COLUMN CONNECTION LOCATION PROVIDE (2) SIMPSON L70 FRAMING ANGLES AT TRUSSES NEAR CONNECTION LOCATION (2) TRUSSES MIN. 5/8" APA RATED ROOF SHEATHING AT TRUSSES AT COLUMN CONNECTION PROVIDE 10d NAILS at 4"o.c. FOR 6'-0" FROM ROOF EDGE T.O.PLATE=112'-10" E 3" 2" 4" 2" HSS COLUMN. RE: PLAN FOR SIZE FABRICATE SADDLE FROM 1/4" STEEL PLATE. ATTACH TO BOTTOM CHORD OF GIRDER TRUSS WITH (4) 3/4" THRU-BOLTS PRE-ENGINEERED GIRDER TRUSS. MAKE BOTTOM CHORD OF TRUSS 2X10 MINIMUM 5/8" APA RATED ROOF SHEATHING 1/4" 3/4" = 1'-0"S5.0 TYP. FOUNDATION DETAIL11 3/4" = 1'-0"S5.0 TRASH ENCLOSURE DETAIL10 COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 7 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S5.0 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 FOUNDATION/FRAMING DETAILS 11/21/2017 3/4" = 1'-0"S5.0 TYP. TUBE STEEL FRAMING DETAIL2 3/4" = 1'-0"S5.0 TYP. TUBE STEEL FRAMING DETAIL3 3/4" = 1'-0"S5.0 TYP. TUBE STEEL FRAMING DETAIL6 3/4" = 1'-0"S5.0 TYP. TUBE STEEL FRAMING DETAIL1 3/4" = 1'-0"S5.0 TYP. TUBE STEEL FRAMING DETAIL4 3/4" = 1'-0"S5.0 TYP. FRAMING DETAIL5 3/4" = 1'-0"S5.0 TYP. FRAMING DETAIL8 3/4" = 1'-0"S5.0 TYP. FRAMING DETAIL9 3/4" = 1'-0"S5.0 TYP. FRAMING DETAIL7 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT INTERMEDIATE NAILING TO FRAMING MEMBERS, REF SCHEDULE 2x WOOD BLOCKING BETWEEN STUDS ACROSS ENTIRE SHEAR PANEL AT ALL PANEL EDGES 2x STUD VERTICAL CHORD (TYP BOTH ENDS OF ALL SHEAR WALLS), REF SCHEDULE SHEAR PANEL BOUNDARIES VARIES, REF PLAN SHEAR PANEL WIDTH CONT DBL 2x TOP PLATE SHEAR PANEL EDGE NAILING, REF SCHEDULE CONTINUOUS TO TRUSS BEARING PLATE SHEAR PANEL CONSTRUCTION REF PLAN 2x WOOD STUDS HOLDDOWN BRACKET OVER "X" DIA THREADED ROD ANCHOR, REF SCHEDULE 2x PLATE, NAIL SHEATHING TO PLATE 1/2" DIA ANCHOR BOLTS AT 36" OC NOTES: 1. HOLDDOWN ANCHORS ARE TO BE INSTALLED USING HILTI HIT-HY 200 MAX ADHESIVE (OR HILTI HIT-RE 500). 2. THREADED ROD SHALL BE A36 (OR APPROVED EQUAL) WITH EMBEDMENT DEPTH PER SCHEDULE. 3. USE ALL WOOD SCREWS AND/OR LAG SCREWS IN HOLDDOWN DEVICES AS SPECIFIED BY MANUFACTURER. 4. SILL ANCHORS MAY BE CAST-IN-PLACE A36 BOLTS OR EXPANSION BOLTS. 5. WSP = WOOD STRUCTURAL PANEL PLYWOOD OR OSB SEE GENERAL NOTES. SHEAR WALL "PANEL" SCHEDULE PANEL MARK SW-1 SW-2 SHEATHING 15/32" WSP 15/32" WSP BLOCKING REQUIRED YES YES EDGE NAILING INTERMEDIATE NAILING TOP PLATE SPLICE CONNECTION SOLE PLATE NAILING/ FASTENING HOLDDOWN ANCHORS MIN # OF STUDS AT HOLDDOWN ALL-THREAD DIA AND EMBEDMENT DEPTH DETAIL REFERENCE 10d at 4"o.c. 10d at 12"o.c. 10d at 12"o.c SIMPSON MSTA30 STRAP 5/8" DIA at 32"o.c. 5/8" DIA at 32"o.c. SIMPSON HDU14-SDS2.5 4 4 1" DIA WITH 12" EMBED 1-S6.0 1-S6.0 S5.1 2 3 S5.1 S5.1 4 10d at 3"o.c. T.O. PLATE=RE: PLAN T.O. SLAB=RE: PLAN 1" DIA WITH 12" EMBED SIMPSON MSTA30 STRAP SIMPSON HDU14-SDS2.5 WOOD SCREWS INTO 2x VERTICAL CHORD, REF MANU SPECS FOR SIZE AND # OF FASTENERS HOLD DOWN BRACKET, REF SCHEDULE ANCHOR ROD, REF SCHEDULE SILL PLATE T.O.C. T.O.F.. EMBEDMENT DEPTH PER SCHEDULE WOOD SCREWS INTO 2x VERTICAL CHORD, REF MANU SPECS FOR SIZE AND # OF FASTENERS ANCHOR ROD, REF SCHEDULE ALTERNATE INSTALLATION LOCATION ROTATED 90 DEGREES ON SIDEWALL IN LIEU OF BACK WALL (NOTE: OPTION AT CORNER LOCATIONS ONLY) HOLD DOWN BRACKER, REF SCHEDULE BETWEEN SPLICES 4' - 0" MIN SPLICE AT BOTTOM 2x 2x STUDS AT 16" OC SPLICE AT TOP 2x TOP PLATE SPLICE CONNECTION, EACH SIDE OF PLATE, TYP, REF SCHEDULE CONT DBL 2x TOP PLATE TOP CHORD APPLIES AT ALL EXTERIOR WALLS 1/2" = 1'-0"S5.1 WALL - Typical Braced Wall Framing1 3/4" = 1'-0"S5.1 WALL - Typical Hold Down Anchor Detail2 3/4" = 1'-0"S5.1 WALL - Typical Hold Down Anchor Plan Detail3 3/4" = 1'-0"S5.1 WALL - Typical Plate Splice Detail4 COLORADOREGISTE R E D43292JAREDMATTHEWLA M B R E C HT P R O F E SSIONAL E N G INEER 2701 LAWRENCE ST. UNIT 19 DENVER, CO 80205 720.588.3222 www.apex-engineers.com 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: CASEWORK CONCEPT: PROJECT #: ISSUE DATE: DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: PR O J E C T N A M E : PR O J E C T A D D R E S S : STARBUCKS COFFEE COMPANY ARCHITECT OF RECORD RLEED AP: C 2015 STARBUCKS COFFEE COMPANY R THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES.STARBUCKS TEMPLATE VERSION i2016.12.23 11 / 2 7 / 2 0 1 7 4 : 4 4 : 3 8 P M G: \ D e n v e r \ P r o j e c t s \ S t u d i o D H A r c hi t e c t u r e \ 2 9 1 0 7 - S t a r b u c k s - E st e s P a r k \ 0 2 - A p e x D r a w i n g s \ R e v it \ 2 9 1 0 7 - S t a r b u c k s E s t e s P a r k _A P E X _ R e v i t 2 0 1 5 c l ea r s p a n t r u s s e s . r v t S5.1 11/21/2017 STARBUCKS - WONDERVIEW AND US 34 537 Big Thompson Ave. Estes Park, CO 80517 SHEAR WALL SCHEDULE 11/21/2017 Revision Schedule Rev Date By Description 07/17/17 OWNER REVIEW 1 11/21/17 FDN/FRAMING REVISION FOR REVISED TRUSS LAYOUT