Loading...
HomeMy WebLinkAboutPLANS 1980 Baldpate Ct Deck 2021-09-13B'B 9' 9' 7'-6"7'-6" 4' 2' 4'-6" 1'-3" 8'8' 1980 BALDPATE CT. ESTES PARK, CO 80517 2x8 @ 16" OC 2x8 @ 16" OC DO W N 3'3' (2) 2X10 BEAM (2) 2X10 BEAM (3) 2X10 BEAM 12" Ø 12" Ø 12" Ø 12" Ø 12" Ø 12" Ø 14" Ø 18" Ø 14" Ø A' A CONCRETE PATIO HOT TUB SIMPSON HUC210-2 18' 12' 1890 BALDPATE CT. ESTES PARK, CO 80517 1980 BALDPATE COURT PROPOSED 16'X18' DECK EXISTING RESIDENCE 10' SET BACK 10' SET BACK 15' SETBACK 15' SETBACK N 8 ° 0 0 ' 0 0 " E 11 0 . 0 0 ' N 82°00'00" W 1 1 0 . 0 0 ' S 82°00'00" E 1 1 0 . 0 0 ' S 8 ° 0 0 ' 0 0 " W 11 0 . 0 0 ' BA L D P A T E C O U R T PROPOSED 12'X18' CONCRETE PATIO GROUND SNOW LOAD = 70 PSF - (10 PSF/1000 FT) * (8000-7670 FT) = 67.0 PSF (INTERPOLATED USING ELEV = 7670 FT) ULTIMATE WIND LOAD = 173 MPH DECK LIVE FLOOR LOAD = 40 PSF DECK SNOW LOAD = INTERPOLATED GROUND SNOW LOAD ELEVATION = 7670 FT, 67.0 PSF SOIL BEARING CAPACITY = 3,500 PSF DECOMPOSED AND FRACTURED GRANITE BEDROCK ALL CONSTRUCTION TO CONFORM TO TOWN OF ESTES PARK STANDARDS AND CURRENT INTERNATIONAL RESIDENTIAL CODE AND ALL OTHER APPLICABLE CODES. DESIGN LOAD CRITERIA: STEP DETAIL SCALE 1/2"=1' B LESS THAN 6" DIA. 2"x6" 2X DECKING TREAD OPEN RISER LESS THAN 4" 10" MIN RUN FROM NOSE TO NOSE 1" TOE 7-3/4" MAX. RISE 4" CONCRETE LANDING (4)2X12 STRINGERS SECTION C-C' TOP CAP 36 " M I N . 6x6 TIMBER POST @ 6' O.C. MAX SPACING (TYP) 1X COMPOSITE DECKING STAINLESS STEEL CABLES W/ 4" O.C. MAXIMUM SPACING 3/4" CHAMFER 1/2" THRU BOLTS DECK RAILING FRONT VIEW SCALE 1/2"=1' (2) 2X10 RIM JOIST 0' - 4 " O C M A X . S P A C I N G 6x6 DF POST (TYP) 12" Ø PIER (2) 1/2" THRU BOLTS (TYP) 2X8 JOIST @ 16" OC 1X COMPOSITE DECKING DECK DETAIL SCALE 1/2" = 1' TOP CAP STAINLESS STEEL CABLES 4" O.C. MAX SPACING (TYP)36 " M I N . A SIMPSON LUS HANGER EACH END SECTION A-A' SIMPSON PB66 POST BASE (2) 2X10 BEAM 30 " M I N . (3) #4 REBAR 4" M A X . 34 " M I N . 2x8 JOIST @ 16" OC 1X COMPOSITE DECKING SIMPSON PB66 POST BASE (3) 2x10 BEAM (3) #4 REBAR 18" Ø CENTER PIER 14" PER PLAN 6x6 DF POST (TYP) 4" CONCRETE PATIO 4" CONCRETE FLOOR SIMPSON COLUMN CAP PC6Z ON CENTER COLUMN EPC6Z ON END COLMNS FLASHING 2X10 PT LEDGER W/ 2-ROWS 3-5/8" LEDGER LOKS @ 12" OC INSTALL SIMPSON DTT1Z @ 4' OC (5 TOTAL) SIMPSON LUS HANGER EACH END STORAGE BELOW DECK STORAGE BELOW DECK 1-ALL DECK JOISTS TO BE @ 16" O.C. UNLESS OF #2 HF OR BETTER OTHERWISE SPECIFIED 2-ATTACH RIM JOIST TO EXISTING BUILDING WITH (2) ROWS OF LEDGER LOK @ 12" OC 3-ALL STRUCTURAL BACKFILL MUST BE COMPACTED TO 95% STANDARD PROCTOR. 4-ALL CONCRETE DESIGN IS BASED UPON "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14). 5-CONCRETE SPECIFICATIONS: Fc = 3,500 psi @ 28 DAYS WITH 6% AIR (Ø 1.5%) 6-ALL WOOD TO BE NATURALLY DURABLE OR PRESSURE TREATED UNLESS OTHERWISE STATED. 7- ALL PIER Ø TO BE AS NOTED ON THE PLANS. NOTES: SCALE 1/4"=1'-0" DECK REPLACEMENT PLAN 1980 BALDPATE COURT LOT 56, CARRIAGE HILLS, 7TH FILING PARCEL # 2406211056 LEGAL DESCRIPTION VICINITY MAP SCALE 1"=700' N SITE PLAN SCALE 1"=30' BY DA T E NO . DE S C R I P T I O N RE V I S I O N S MST MST MST PLOTTED: SHEET: ONLY VALID FOR CONSTRUCTION DRAWN BY: CHECKED BY: ARE ON EACH SHEET IF ORIGINAL SEAL & SIGNATURE DESIGNED BY: 1 of 1 JOB NUMBER: 967-001 9/13/2021 20 1 9 C O R N E R S T O N E E N G I N E E R I N G & S U R V E Y I N G , I N C . CO P Y R I G H T - A L L R I G H T S R E S E R V E D 16 9 2 B I G T H O M P S O N A V E . SU I T E 2 0 0 ES T E S P A R K , C O 8 0 5 1 7 PH : ( 9 7 0 ) 5 8 6 - 2 4 5 8 FA X : ( 9 7 0 ) 5 8 6 - 2 4 5 9