HomeMy WebLinkAboutPERMIT 1040 Big Thompson Ave, Estes Valley Inn Building B Lobby Renovation 2022-07-05 Commercial Remodel Estes Park 170 MacGregor Ave Suite 230, Estes Park, CO 80517 22-EP-00365 (970) 577-3726(970) 586-0249 Application Details Application Date:07/05/2022Property Owner:Castle Peak Holdings Acceptance Date:07/05/2022Mailing Address:1040 Big Thompson Avenue Job Site Address:1040 Big Thompson Avenue, Estes Park, CO 80517 Estes Park, CO 80517 Category:Commercial Alteration Phone:(626) 616-0864 Type:Commercial Remodel Email:david@castlepeakholdings.com Description of Work: Building B main lobby renovation. Includes lobby alterations, rear office finishes, removing back "office" overbuild on decking, and converting back to deck space. Modernization of HVAC system, structural reinforcement under lobby and at back deck. sitework improvements Contractors:Applicant: Name: Phone: Email: PrimaryHumphrey Rich Construction Group (301) 330 Tom Garcia(240) 793-6191tgarcia@hrconstruc -1650 tion.com Occupant: Name: Phone: Email: Fields # Parking Spaces:# Stories: Auto Sprinkler System Gbmtf Construction Type: Required: Estimated Valuation:$350,000.00 Designed Occupant 1 Occupancy R-1 Residential, hotels Load: Classification: Mixed Occupancy: UTSD/EPSD OR unknown 3-::3 Total Square Footage:SEPTIC: Application Terms Submitted by: pvillano@safebuilt.com This document is NOT a permit and does not constitute approval or authorize any construction or changes to the above location. Town of Estes Park Department of Building SafetyPermit #: __________________ 170 MacGregor Ave App Exp: ___________________ Suite 230Permit Exp: ________________ Estes Park CO, 80517Date Rcvd: _________________ 970-577-3726Rcvd by: ___________________ building@estes.org BUILDING PERMIT APPLICATION Description: CvjmejohCnbjompcczsfopwbujpo/Jodmveftmpcczbmufsbujpot-sfbspggjdfgjojtift-sfnpwjohcbdl #pggjdf#pwfscvjmepoefdljoh-boedpowfsujohcbdlupefdltqbdf/Npefsoj{bujpopgIWBDtztufn- tusvduvsbmsfjogpsdfnfouvoefsmpcczboebucbdlefdl/tjufxpsljnqspwfnfout !Dbtumf!Qfbl!Ipmejoht737.727.1975 Property Owner:Phone: ebwjeAdbtumfqfblipmejoht/dpn 2151CjhUipnqtpoBwf-FtuftQbsl-DP91628 Job Site Address:Email: Ivnqisfz!Sjdi!Dpotusvdujpo!Hspvq-!Jod/351.8:4.72:2 Primary Contractor:Phone: Boesfx!TqbjobtqbjoAisdpotusvdujpo/dpn Contact Name:Email: Sub-Contractors: NamePhoneEmail 1 2 3 4 5 IMPORTANT - COMPLETE ALL ITEMS AND MARK ALL APPLICABLE ITEMS Square FootageNew or Tenant Finish OnlyCommercial 2-6:1 Main Flr: __________________Residential________Shell Only Add Flrs: _______________________One Family________Tenant Finish y 2-513 Basement: _____________________Multi-Family: ________Remodel/Addition Crawlspace: _______________# of Units: _________________________New Building 691 Decks: _________________________Hotel, Motel, Dormitory:________Sign 5 Covered Porch: ____________# of Units ___________________Sprinkler: YesNo Garage: ________________________Garage Occupancy S.2 Other: ____________________Attached/DetachedClassification: _____________ W!C Miscellaneous _____PatioConstruction Type: _________ ____Plumbing____GasAttached/DetachedSeparated/Non-Seperated ____Mechanical____Roof_____Basement: Partial/Full Construction Type y ____Grading___SolarFinished/Unfinished____Wood ____Windows___Other_____Fireplace____Structural Steel ____Fireplace_____Other____Masonry Demolition# of Bedrooms: ____________Other %461-111/11 Site Plan: _________________# Full Bath: ________Valuation: _________________ State Permit: ______________# 1/2 Bath:____ #3/4 Bath: ____Total Fees: _________________ Asbestos Permit: ___________Notes: Applicant Signature: _______________________________________________Date: ____________ Building Official Signature: __________________________________________Date: ____________ Certified Testing, Adjusting, and Balancing Report Project Information Report Revision Information Project Name: Estes Village Inn Address: 1040 Big Thompson Ave. Estes, Park, CO 80157 Reviewing Supervisor Signature Elevation: 7,522 ft. Certified Report Date: September 13, 2023 Contractor Information Contractor: Everest Mechanical Mechanical Engineer: Architect: Company Certification Information Alnor EBT Micromanometer EBT-731: May 2023 Alnor Hydronic Manometer HM675: May 2023 Fluke 323 True RMS Clamp meter: May 2023 Semper Fidelis Veteran Owned and Operated Warranty Information Dear Customer, As we try to build our customer base and ensure your complete satisfaction on every project United Test and Balance would like to extend a 180 Day warranty policy for every project. The terms of the warranty are listed below: United Test and Balance does hereby warrant the above-mentioned completed project for a period of 180 Days from the date of the issued Certified Test and Balance Report. That said work shall remain free from all defects in workmanship and material, and that it shall comply with all the specific requirements of the Specifications and other Contract Documents governing the Testing, Adjusting, and Balancing. It is understood and agreed upon that in the event of defects and the necessity of making repairs, the Owner and/or Contractor will immediately notify United Test and Balance in writing of its conditions and shall give the contractor reasonable time, 30 days, in which to make said repairs. If any person, firm, or corporation other than United Test and Balance has, since the completion of the above work, performed or attempted to perform any repairs to the Mechanical Systems then this warranty will become null and void. This warranty does not cover any repairs made by anyone other than United Test and Balance or one of its authorized representatives. Thank you for the opportunity to work with you on this project and we look forward to working with you in the future. Sincerely, Ytt|ˆ \\tx{{ Jeremy Merrill Owner T.A.B.B. Certified Supervisor Semper Fidelis Veteran Owned and Operated Abbreviation Index AC Air Conditioning Unit KW Kilowatt AHU Air Handling Unit LAT Leaving Air Temperature AMP or A Ampere LB Pound APD Air Pressure Drop LWT Leaving Water Temperature ATMOS Atmosphere MA Mixed Air BHP Brake Horsepower MAX Maximum BTU British Thermal Unit MIN Minimum BTUH BTU per Hour MAU Make-Up Air CFM Cubic Feet per Minute N/A No Access CHW Chilled Water Nom. Eff. Nominal Efficiency CHWR Chilled Water Return OSA Outside Air CHWS Chilled Water Supply OD | ID Outside Diameter | Inside Diameter CT Cooling Tower P Pump CUH Cabinet Unit Heater PD Pressure Drop CWR Condenser Water Return PF Power Factor CWS Condenser Water Supply PFPB Parallel Fan Power Box DB Dry Bulb (Temperature) PH Phase DEG or ° Degree PSI Pounds per Square Inch Differential Pressure RA Return Air Differential Temperature RET Return (E) Existing RG Return Grille EA Exhaust Air RH Relative Humidity EAT Entering Air Temperature RPM Revolutions per Minute EF Exhaust Fan RTU Roof-Top Unit ER Exhaust Register SA Supply Air ERV Energy Recovery Ventilator SD Supply Diffuser ESP External Static Pressure SP Static Pressure EWT Entering Water Temperature SF Service Factor °F Fahrenheit SFPB Series Fan Power Box FPB Fan Power Box sq. ft. Square Feet FCU Fan Coil Unit T-1|T-2 |T-3 Terminal 1|Terminal 2|Terminal 3 FLA Full Load Amps TEMP or ° Temperature FPM Feet per Minute TSP Total Static Pressure FT. Feet T-Stat Thermostat HD. Head V Volts HP Horsepower VAV Variable Air Volume HWR Hot Water Return VFD Variable Frequency Drive HWS Hot Water Supply VP Velocity Pressure HZ Hertz (Cycles per Second) WB Wet Bulb Temperature IN. Inches W.C. Water Column KEF Kitchen Exhaust Fan W.G. Water Gauge Semper Fidelis Veteran Owned and Operated Qbhf!2!pg!9 Qbhf!3!pg!9 Qbhf!4!pg!9 Qbhf!5!pg!9 Qbhf!6!pg!9 FG.12.12 Qbhf!7!pg!9 GDV.12 FSW.12 GDV.12 Qbhf!8!pg!9 FG.12.13 Qbhf!9!pg!9 LARIMER COUNTY | HEALTH AND ENVIRONMENT 200 Peridot Avenue, Loveland, Colorado 80537, 970.619.4580, Larimer.org/health March 31, 2023 Moira Terry Big Thompson Property LLC 1040 Big Thompson Avenue Estes Park, Colorado80517 Dear Ms. Terry, The plans and specifications submitted for the constructionof Estes Village Inn located at 1040 Big Thompson Avenuein Estes Park, Colorado, have been reviewed by this department. The following items are specific to the submitted plans and must be completed in order to maintain compliance with the Colorado Retail Food Establishment Rules and Regulations. The plans areapproved at this time. 4§¤ ¥®««®¶ing¨³¤¬² ±¤°´¨±¤ ¬®£¨¥¨¢ ³¨®­² ³® ³§¤ ¯±®¯®²¤£ ¯« ­²Ǿ  ­£ ±¤²¯®­²¤²  ­£ȝ®± ±¤µ¨²¤£ ¯« ­² ¬´²³ ¡¤ ²´¡¬¨³³¤£Ȁ 15. 0,%!3% ./4%Ȁ This letter contains important information and advisements for the construction of the establishment. Establishment owners are responsible for items noted in this letter. Please share this letter with all involved parties, including the construction superintendent and contractors at the construction site. If there are any questions regarding information in this letter or anything else related to the construction and operation of the establishment, please call at (970) 966-3529or madarice@larimer.org. -¤­´  ­£ &®®£ ( ­£«¨­¦Ȁ 1.A menu was provided as part of the plan review submission. The menu will include overnight oats, yogurt and berries, andmuffins. Food preparation for overnight oats and yogurt and berries will be conducted at Twin Owls Motor Lodge, which is currently under construction with an approved plan review letter. 2.Written food handling procedures for the operation were not submitted, but food handling procedures were outlined in the plan review application. To promote active managerial control for safe food handling, written procedures should be created and employees should be properly trained on written procedures. Staff should also be regularly monitored to ensure the proper procedures are being practiced. Please incorporate the following: a)Protocols and/or systems should be created and used to monitor food and equipment temperatures. It is recommend that logs be used to monitor temperatures of cold and hot holding equipment, as well as the temperatures during the cooling and reheating of foods. b)!Please be advised, room temperature prepared foods are also required to under go rapid cooling. Rapid cooling requires prepared foods to be cooled from post- preparation temperature to below 41F within four hours. This is required for prepared products such as sliced tomatoes, sliced meat and cheeses, as well as canned/jarred products that require refrigeration after opening. Covering these items immediately after preparation and placing the products in the refrigeration units is not approved. Only after the product has quickly cooled to less than 41ºF, may the product be covered for storage. c)!Proposed procedures/methods that will be used to thaw frozen foods. d)!Date marking procedures are required for all food service operations. Refrigerated, ready-to-eat potentially hazardous foods prepared and held in the establishment for more than 24 hours will be required to be clearly marked to indicate the date by which the food is to be consumed, sold, or discarded. These foods must then be consumed, sold, or discarded within 7 days. e)!Written policies for restricting and excluding ill employees were not provided. Please be advised, written policies should be in place and used to restrict or exclude employees who are ill. !An employee must be excluded from work if the food employee is symptomatic with vomiting or diarrhea, jaundice, sore throat with fever, except when the symptom is from a noninfectious condition (examples: allergic reaction/intolerance). The employee cannot return until they are symptom free for a minimum of 24 hours, but 48 to 72 hours is recommended. !Employees diagnosed with a Health Department reportable illness such as Norovirus, Hepatitis A virus, Shigella spp., Enterohemorrhagic or Shiga Toxin-Producing Escherichia coli, Salmonella Typhi; or other enteric bacterial pathogen such as Salmonella or Campylobacter, must be excluded from work. ! before an employee can return to work if diagnosed with any of the infections listed above. !Keep records to identify employee schedules to monitor scheduled hours, sick leave and shift changes. f)!Procedures for employees to follow when responding to vomiting or diarrheal events within the establishment must be developed. For a printable guidance document regarding Clean-up Procedures for Vomit/Fecal Events, please visit: https://www.larimer.org/sites/default/files/uploads/2017/lcdhe-vomit- diarrheal-guidance.pdf g)!Please be advised, employees must be excluded from working with food, beverages and clean equipment when wounds are expressing fluids and not able to be contained. Wounds and cuts on fingers, hands or wrists, must be properly covered with a double barrier, such as a cut covered with a band aid then covered with a finger cot or glove. h)!Please be advised, barehand contact with ready-to-eat foods is prohibited. Gloves are required when utensils and other barriers cannot be used when handling or preparing ready-to-eat foods that will not be further cooked. Employees are required to wash hands prior to applying gloves. Written procedures should be created for proper handwashing and glove use. %°´¨¯¬¤­³Ǿ #«¤ ­¨­¦Ǿ  ­£ !¢¢¤²²¨¡¨«¨³¸Ȁ 3.All food service equipment must be designed for its intended use and should be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, such as NSF, ETL Sanitation, UL Sanitation, or BISSC Certified. a)!Custom made and used equipment cannot be approved until it is visually inspected. This also includes cabinetry and other millwork. 4.!No hot foods will be served, and hot holding equipment submitted in the plan review will not be installed. Please be advised if the menu changes or if the proposed refrigeration/hot holding equipment is found to be inadequate during routine inspections, additional equipment will be required. 5.!Please be advised, heavy floor mounted equipment such as refrigerated make table coolers, reach-in coolers and freezers, ice machines, and equipment stands/tables, must be mounted on casters to allow for mobility and easy cleaning of the equipment, surrounding surfaces and adjoining equipment. The following equipment will be required to be on casters or on six inch sanitary legs: a)!Reach in coolers b)!Ice machine 6.!Heavy counter mounted equipment such as ice and beverage dispensers and espresso machines, which cannot be easily moved for cleaning, must be installed on four inch sanitary legs or neatly sealed to counters to facilitate cleaning. 7.!Please be advised pallets, dunnage racks, shelves and other floor racking systems, must be installed in a manner that will not inhibit or prevent easy cleaning of floors and surrounding surfaces. a)!Storage shelves located in all food preparation areas and storage areas must be situated at least six inches off the floor. b)!Wooden shelving or pallets are not approved for use in coolers and freezers, nor in storage, kitchen and warewashing areas. 8.!Hard to clean spaces or gaps around equipment, counters, utilities and plumbing must be eliminated to provide for easy cleaning. All equipment, cabinets or counters that are not mounted on casters or are not easily moveable (curb mounted or legs) must be: a)!Neatly sealed to adjoining walls, equipment, cabinets or counters; or, b)!Spaced so the surfaces of the floors, walls and exterior surfaces of equipment and cabinets can be easily cleaned: c)!Please be advised, if equipment is less than 2 feet in length, then the equipment must be installed 6 inches minimum from the back wall if it is not installed flush with the wall. d)!Please be advised, if equipment is more than 2 feet in length, then the equipment must be installed 12 inches minimum from the back wall if it is not installed flush with the wall. 9.!No accessories such as syrup lines, carbonators, drop-in cold plates, drain lines or drained bottle holders, are permitted in potable ice bins or any unit used to store potable ice. Ice used for beverages must be stored in an approved indirectly drained ice bin. Ventilation: 10.!This operation is not approved for any type of cooking. 11.!Restrooms must be provided with mechanical exhaust ventilation to the outside. Plumbing: 12.!An approved stainless steel food preparation sink with a minimum of one 18 inch drain board must be provided if fresh produce is prepared as part of a standard menu item. Be advised, this sink must be indirectly drained to sewer. 13.!Please be advised the 3-compartment warewashing sink basins must be large enough to accommodate all equipment used in food preparation and storage. 14.!Warewashing drain boards must be self-draining and directed to warewashing sink basins, pre-rinse sinks, scuppers or warewashing machines. a)!where food and beverages are served on single service products; 15.!Please install a wall mounted wire rack be installed above the 3-compartment sink that is as long as the length of the sink to accommodate air drying and storage of cleaned equipment. 16.!It was indicated that no garbage disposal will be installed. 17.!Hand washing sinks must be easily accessible in all areas where food is prepared, served or where utensils and equipment are washed. 18.!All hand washing sinks must be provided with hot and cold running water under pressure through a mixing valve, single service hand towels from a dispenser and hand soap. 19.!The proposed hand sink location is approved. 20.!Please be advised of the following requirements for hand washing sinks: a)!The height of the hand washing sink must be between 30 inches and 48 inches above the floor. b)!The sink basin must be a minimum of 10 inches in any direction. 9 inches by 9 inches hand sink basins are not approved. c)!When installed in a countertop, the hand sink basin must be within 24 inches of the front of the counter. d)!The space between the flood rim of the hand sink and the base or underside of any cabinet located above the sink must be at least 24 inches. e)!Hand sink faucets must be installed on the side of the sink basin directly opposite the user. f)!A sign or poster that notifies food employees to wash their hands will need to be displayed at all hand washing sinks. 21.!A mop sink for the disposal of mop water and for the purpose of filling mop buckets and cleaning mops has been proposed. a)!The mop sink must be provided with hot and cold running water. b)!Mop and broom hangers must be provided at the mop sink to properly hang and air dry mops. c)!Storage shelves should also be provided to properly store cleaning supplies. 22.! Please be advised, if installing chemical dispensing units at plumbing fixtures, the following is required: a)!Please be advised, chemical dispensing units must be supplied with both hot and cold running water at 3-compartment sinks and mop sinks. b)!When installing chemical dispensers at the mop sink, chemical towers must have an integrated ASSE 1055 backflow prevention device or be equipped with an air gap, or if chemical towers lack integrated air gaps or backflow prevention devices, the use of wasting Ts in conjunction with chemical towers is approved. c)!When installing chemical dispensers above the 3-compartment sink, the dish detergent and the sanitizer must be stored above the soiled drain board and/or washing basin of the 3-compartment sink, or below the drain board/sink. 23.!The proposed water heating system, State water heater, model ENG6-30, with a 6 KW rating is approved. This water heater is only approved to service the kitchen space, and cannot be used for other areas. 24.!Please be advised, the water heater is required to be installed on a six inch leg kit if the heater is installed on the floor. A minimum of six inches of clearance must be provided between the walls and the water heater to facility cleaning around the water heater. 25.!Please be advised, all drains from equipment such as ware washing sinks, food preparation sinks, dish machines, ice machines, ice bins, drink dispensers, drink overflow drains, drink gun holster drains, and refrigeration/freezer units not provided with evaporation pans, must be directed to a floor drain or floor sink and be properly air gapped. a)!Please be advised floor sinks must not be installed under equipment or cabinetry where they cannot be cleaned. b)!All floor sinks and floor drains must be installed so they are flush with the finished floor. 26.!Please be advised approved, properly installed, backflow devices must be provided on all submerged inlets (e.g. garbage disposal, steam tables), dish machines, hose bibs, rinse hoses that do not have an air gap, water softeners and beverage dispensers. Backflow devices on water lines subject to back pressure or continuous pressure must be equipped with backflow preventers that are designed for continuous pressure. 27.!Please be advised, the excessive installation of surface mounted utility/service lines is not approved per NSF installation standards for food/beverage service operations. Utility/service lines running along the surface of finished walls, ceiling and floors, are not approved and must be installed behind cabinetry or within a framed wall. 28.!Electrical conduit, plumbing (water and drain lines), data service lines, and other utility/service lines must be located behind walls, within cabinetry, above finished ceilings or below floors in finished food and beverage preparation/service areas. 29.!External floor or wall mounted Uni-strut or hard to clean brackets are not approved to support utility/service and drain lines. 30.!Exposed water pipes, sewer lines, gas lines or electrical conduit running along the surface of the walls, ceiling or floors are not approved. a)!All drain lines, water lines, gas lines and electrical conduit running along the walls in finished rooms must be boxed in or completely concealed along the wall to facilitate easy cleaning. b)!External floor or wall mounted Uni-strut or hard to clean brackets are not approved to support utility and drain lines. 31.!Please be advised sewer lines, waste water lines and roof drains can not be located above stored foods, single use items, utensils and equipment in warehouse areas unless guttered or protected. 3³±´¢³´±¤Ǿ &¨­¨²§¤²Ǿ '¤­¤± «: 32.!Adequate lighting must be provided where food is processed or stored, where equipment and utensils are cleansed, as well as in restrooms and bar area. a)!At least 50 foot candles of light are required on all surfaces where food is prepared and equipment and utensils are washed. b)!At least 20 foot candles of light must be provided on all other surfaces within kitchen areas, storage areas, service counters, restrooms, utensil and equipment storage areas and custodial closets. 33.!All lights in the above areas, except restrooms and custodial closets, must be shielded in an approved manner. All lights inside equipment and above open food must also be shielded. 34.!Please be advised that additional light fixtures may be required if it is determined that the light levels are inadequate during construction. 35.!To help prevent insect and rodent entry into the building all outer openings including doors and windows must be kept closed or permanent screens or air curtains must be installed on outer openings that will be left open periodically. 36.!Weather stripping, threshold and/or broom sweeps must be installed on all outside doors to eliminate gaps to the outside. 37.!All exit and restroom doors must be fitted with self-closures. 38.!Please be advised floors, walls, ceilings, counter tops, storage shelves, cabinets and all work surfaces, located within all kitchen and food preparation areas, storage areas, custodial closets, restrooms, serving areas, wait station, and ware washing areas must be of an approved material that is smooth, durable, non-absorbent and easily cleanable. a)!All floor/wall junctures and stationary equipment floor junctures in the above listed areas must be provided with approved concave coving. b)!If ceramic/quarry tile coving is provided, the cove base tiles must be installed flush with the finished floor tile. Top set of ceramic/quarry tile base is not allowed. Vinyl/rubber cove base must be neatly sealed to the floor and wall. c)!Paints used on the walls and ceilings must be washable, without removing the paint when cleaned. Light colored, high gloss paint is recommended. 39.!The outside trash and recycling areas must be located on a cleanable surface of concrete or machine laid asphalt. 40.!Toxic materials and surplus cleaning supplies must be stored below or away from food preparation areas, food, utensil and single service item storage areas and ware washing facilities. 41.!tems, such as coats, clothing, backpacks and handbags, that is separate from food and clean equipment. 42.!The following items are required where food handling and warewashing occur in the establishment: a)!food product thermometers scaled 0 to 220°F, digital thermometers or thermocouple b)!f gloves and finger cots c)!approved sanitizer d)!test strips for the sanitizer Be advised approval of plans, including the above modifications outlined in this plan review letter, does not constitute acceptance of the completed structures. Inspections of the premises must be conducted by this department prior to approval for operation and licensure of the establishment. Failure to follow the recommended changes may prevent or delay licensure. The establishment is required to obtain a Retail Food Establishment License. An application for the required license will be provided by the department prior to the opening inspection. Construction checks are a critical and are considered a continuation of the plan review process. At least one construction check is required for all establishments undergoing plan review and will be charged at $85.00 per hour. Additional construction checks may be required based on request or establishment need. In addition to the $100 plan review application fee paid at the time the plans were submitted for review, a review fee is assessed for the actual review time. The review fee is assessed at a rate of $85 per hour. Current review cost for this project is $212.50. Please be advised, before the department can give any approval for operation all plan review fees must be paid. Be advised that Colorado Revised Statutes (2009) 25-4-1605 requires that plans and specifications be submitted to the local health department and approved prior to beginning construction. Please feel free to contact this department if questions arise, or if I can be of further service at 970-966-3529 or madarice@larimer.org. Sincerely, Clare Madaris Senior Environmental Health Specialist cc: Town of Estes Park Division of Building Safety via electronic mail INSPECTION CARD Estes Park 170 MacGregor Ave Suite 230, Estes Park, CO 80517 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. Commercial APPLICATION NO.:22-EP-00365TYPE:ISSUED DATE:09/14/2022EXPIRATION DATE:05/20/2024 Remodel PROJECT ADDRESS:1040 Big Thompson Avenue, Estes Park, CO 80517PARCEL NO.:2519306002 OWNER:Castle Peak HoldingsCONTRACTOR:Humphrey Rich Construction GroupCONTRACTOR PHONE:(301) 330-1650 Building B main lobby renovation. Includes lobby alterations, rear office finishes, removing back "office" overbuild on decking, DESCRIPTION OF WORK: and converting back to deck space. Modernization of HVAC system, structural reinforcement under lobby and at back deck. sitework improvements CONSTRUCTIONTYPE:OCCUPANTLOAD: DATE DATE INSPECTIONINSPPASSEDCOMMENTSINSPECTIONINSPPASSEDCOMMENTS FootingsJG10/25/2023Underground PlumbingJG10/25/2023 Rough PlumbingJG6/5/2023See NotesRough MechanicalGR4/4/2023See Notes Rough FrameJG10/25/2023Gas TestJG6/6/2023 FirestoppingJG10/10/2023Above Ceiling JG10/10/2023 InsulationJG4/7/2023See NotesFinal PlumbingJG10/10/2023 Final MechanicalJG10/10/2023Final FireJJ10/16/2023 Final Public Works/COJW9/21/2023Final Sanitation/COJD10/18/2023See Notes Final Building/COGR11/22/2023 Engineering Fire Approval:Date:Date: Approval: PW Approval:Date:Other ( ):Date: To request an inspection: Page 1 of 1 regulating building Estes Park Y C Commercial Remodel 22-EP-003652519306002Gary RusuNo N ::::: :::: l t t r k e #n d ca o e ci i tp A o e i ir L b c o y t d i l s i f i s m T m f P i v B r v t i u io e DO r d N U P m g bg P l r n un g r e eii nc C e S nd i Pl r l i o k d a l u i Z n C i P u B r p B O S o 11/22/2023 t F u - A O E Estes Park T Estes Park A For C I construction and use. F I T R E C 1040 Big Thompson Avenue, Estes Park, CO 80517N/A R-1N/A2015 International Building Code (IBC)No 1040 Big Thompson Avenue, Estes Park, CO 80517Castle Peak Holdings :: ::: ::: yy ss nnd e cc ss ooe ii m r nn ee tt i i rr a caa u d dd p up N q r dd E uu rt e AA cc s e e R cc r n n d e r t e o OOo i w e n l C S C d O k w f e n oi x O r i e p M p S y o T t u A of issuance this structure was in compliance with the various ordinances of This certificate is issued pursuant to the requirements of the adopted building code, certifying that at the time