Loading...
HomeMy WebLinkAboutPLANS 20-B-00017 Rocky Mountain Hotel Approved 1701 North Lake Ave 2020-04-28CONTRACTORS RESPONSIBILITIES 1. OWNER & BUILDER TO PROVIDE & INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. 2. ELECTRICAL & PLUMBING TO CONFORM TO THEIR CURRENT RESPECTIVE CODES ADOPTED BY ANY AND ALL GOVERNING AGENCIES HAVING JURISDICTION OVER THIS PROJECT. 3. ARCHITECTURAL DETAILS THAT SHOW OR INDICATE STRUCTURAL SYSTEMS AND/OR COMPONENTS ARE FOR GENERAL REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS FOR SYSTEM SPECIFICATIONS, DESIGN, LAYOUT, ETC... RELATED TO THEIR TRADE. 4. THE CONTRACTOR SHALL VERIFY THAT THE BUILDING CODE REQUIREMENTS, AS ADOPTED BY THE LOCAL MUNICIPALITY, HAVE BEEN MET. ALL WORK CONTAINED WITHIN THESE DOCUMENTS SHALL CONFORM TO ALL CODES, REGULATIONS, ORDINANCES, LAWS, PERMITS & CONTRACT DOCUMENTS WHICH APPLY. 5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS, INSPECTIONS, LICENSES AND APPROVALS ASSOCIATED WITH THIS PROJECT. 6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EQUIPMENT SIZES AND LOCATIONS WITH PLUMBING, ELECTRICAL AND UTILITY COMPANIES. 7. THE CONTRACTOR MUST VERIFY THE BUILDING LAYOUT WITH THE SURVEYOR PRIOR TO EXCAVATING THE FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE. 8. THE CONTRACTOR MUST VERIFY THAT ALL DOORS, WALLS AND CEILINGS BETWEEN THE EXISTING BUILDING & THE NEW ROOF TOP DECK / COVERED ENTRY WITH POSSIBLE UPPER ROOF CANOPY MEET ALL FIRE AND SAFETY CODES AND REGULATIONS. 9. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING ALL EXISTING AND FINISH GRADES ON SITE. 10. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 11. THE CONTRACTOR AND THEIR SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLETING ALL THE WORK WITHIN THESE DOCUMENTS, UNLESS NOTED OTHERWISE. 12. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, AC EQUIPMENT, RECESSED ITEMS AND ALL OTHER ITEMS AS REQUIRED. 13. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION. 14. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ETC… VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. 15. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT AND/OR ENGINEER. ALL SUCH PORTIONS OF THE WORK SHALL BE INSTALLED IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS AND SAMPLES. 16. THE CONTRACTOR SHALL CONFINE THEIR OPERATIONS ON THE SITE TO THE AREAS PERMITTED BY THESE DOCUMENTS AND THE OWNER. 17. MOISTURE IS THE PREVALENT CAUSE OF MOLD GROWTH. GENERAL CONTRACTOR AND SUBCONTRACTORS ARE TO BE PROACTIVE IN THE MITIGATION OF MOISTURE DURING CONSTRUCTION. STRUCTURAL CHANGES 1. ANY CHANGES IN THE FIELD TO THE STRUCTURAL PLANS SHALL RELIEVE THE ARCHITECT AND STRUCTURAL ENGINEER FROM ANY CONSEQUENCES WHICH MAY ARISE. DISCREPANCIES 1. ANY DISCREPANCIES IN THE FIELD TO THE STRUCTURAL PLANS SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY. ANY FAILURE TO REPORT DISCREPANCIES SHALL RELIEVE THE ARCHITECT OF ANY CONSEQUENCES WHICH MAY ARISE. ELECTRICAL 1. THE ELECTRICAL SYSTEMS ARE DESIGN-BUILD. MECHANICAL 1. THE PLUMBING SYSTEMS ARE DESIGN-BUILD. 2. ALL PLUMBING SYSTEMS TO BE DESIGNED & INSTALLED PER ALL APPLICABLE GOVERNING CODES. 3. ALL PLUMBING SYSTEMS TO BE COORDINATED WITH RELATED AND ADJACENT TRADES BOTH IN DESIGN & INSTALLATION. NOTE: THIS IS A BUILDERS SET OF DRAWINGS. OWNER AND BUILDER TO PROVIDE AND INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. BUILDERS SET OF PLANS PROJECT SITE Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 3 5 A M A001 PROJECT COVER SHEET T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L REM O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 PROJECT INFORMATIONBUILDERS NOTE VICINITY MAP PROJECT TEAM A001 PROJECT COVER SHEET A110 FLOOR PLAN & ELEVATIONS (EXISTING) A111 FLOOR PLAN (EXISTING) A120 FLOOR PLAN & ELEVATIONS PROPOSED A121 FLOOR PLAN & ELEVATIONS PROPOSED A122 SITE A130 REFLECTED CEILING PLAN A300 BUILDING SECTIONS SN100 GENERAL STRUCTURAL NOTES S100 FOUNDATION PLAN AND DETAILS S200 DECK FRAMING PLAN AND DETAILS S300 ROOF FRAMING PLAN AND DETAILS E001 ELECTRICAL COVER SHEET E100 REFLECTED CEILING PLAN E200 ONE LINE DIAGRAMS AND PANEL SCHEDULES E300 LIGHTING COMCHECK SHEET INDEX STRUCTURAL: SURVEYOR: GENERAL CONTRACTOR: ARCHITECT: ERIC SMITH ASSOCIATES, P.C. 1919 7TH STREET BOULDER, CO 80302 303-442-5458 303-442-4745 FAX PROJECT ARCHITECT: TOM JARMON EMAIL: Tom@esapc.com NOT TO SCALE NORTH AREA: BUILDING PERMIT SET FOR: ROCKY MOUNTAIN HOTEL NEW ROOFTOP DECK / COVERED ENTRY WITH POSSIBLE UPPER ROOF CANOPY APPLICABLE CODES: • 2015 IBC(INTERNATIONAL BUILDING CODE) • 2015 IMC (INTERNATIONAL MECHANICAL CODE) • 2015 IPC (INTERNATIONAL PLUMBING CODE) • 2015 IFGC (INTERVENTIONAL FUEL GAS CODE) • 2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE) • 2017 NEC (NATIONAL ELECTRICAL CODE), VERIFY ZONING DISTRICT:ACCOMMODATIONS (A) ROOF TOP DECK: +/-1,418 SF ACCESSIBILITY: PROVIDE ACCESSIBLE ACCESS WITH LOW PROFILE THRESHOLD TO NEW ROOFTOP DECK/ COVERED ENTRY FROM EXISTING BUILDING 2ND LEVEL @ NEW STOREFRONT DOOR. FENESTRATION SCHEDULE CLIMATE ZONE: 5B NEW STOREFRONT DOORS 2015 IECC MIN. VALUES PROVIDED U=0.77 U=0.77 OR BETTER NOTE: NEW 2ND LEVEL STOREFRONT DOORS TO MEET 2015 IECC SHGC DEPENDING ON ROOF OVERHANG OF POSSIBLE UPPER ROOF CANOPY. Advanced Hospitality Management LLC. Kumar Merchant, Principal 6860 S Yosemite Ct #1404 Centennial, Co 80112. Phone: 720-357-7960 E-mail: kumar@advancedhospitalitymanagement.com VAN HORN ENGINEERING & SURVEYING LONNIE SHELDON TIM NEARY 1043 FISH CREEK ROAD ESTES PARK, CO 80517 OFFICE:(970) 586-9388 lonnie@vanhornengineering.com tim@vanhornengineering.com CODE ANALYSIS: R-1 BUILDING OCCUPANCY FOR THE HOTEL. TYPE IIIB NEW CANOPY CONSTRUCTION WITH HEAVY TIMBER AT THE UPPER CANOPY ROOF. A-3 OCCUPANCY AT THE NEW CANOPY WITH 1,418 NET SF WHICH DIVIDED BY 15 NET SF PER OCCUPANT = 94.5 OCCUPANTS. THE NEW CANOPY 2ND EXIT IS PROVIDED WITH THE NEW EXTERIOR STAIR AT THE SOUTH END. 1701 NORTH LAKE AVE ESTES PARK COLORADO 80517 LEGAL DESCRIPTION: LOT 2 NORTH LAKE SUBDIVISION EP OWNER: ASTRA ENGINEERING INC. MYRON L. JACOBSON, PE 7887 E. BELLEVIEW AVENUE, SUITE 1100 ENGLEWOOD, CO 80111 PHONE: (720) 767-4567 myron.astra@gmail.com GREER CONSTRUCTION, INC. BEN GREER, PRESIDENT LEED AP 620 S. 44TH ST. BOULDER, CO 80305 PHONE: 303-775-7974 ben@greer-construction.com GENERAL NOTE 1. GENERAL CONTRACTOR TO VERIFY EXISTING HOTEL BUILDING 2ND LEVEL ELEVATION TO COORDINATE THE FINISHED ELEVATION OF THE NEW CONCRETE ROOFTOP DECK ADA ACCESSIBILITY ACCESS ONTO THE NEW ROOFTOP DECK SURFACE AT THE NEW HOTEL 2ND LEVEL ROOFTOP DECK ACCESS DOOR LOW PROFILE ADA ACCESSIBLE THRESHOLD.ALL BUILDING AND STEEL ELEVATIONS TO DEVELOP FROM THIS RELATIONSHIP FROM THE EXISTING 2ND FLOOR HOTEL FLOOR TO THE NEW ROOFTOP DECK. 2. PROVIDE STUCCO REPAIR/PATCH AS REQUIRED AT ALL NEW AND EXISTING LOCATIONS AS REQUIRED. SCOPE OF WORK SCOPE OF WORK TO INCLUDE 1. PORTION OF THE EXISTING PORTE-COCHERE SHALL BE REMOVED AS REQUIRED FOR THE REMODEL. THE EXISTING EXTERIOR COLUMNS SHALL REMAIN AND BE COORDINATED WITH THE STRUCTURAL SECTION OF THE CONSTRUCTION DRAWINGS. 2. NEW ROOF TOP DECK / COVERED ENTRY WITH EXTERIOR STAIRS. 3. AND NEW STOREFRONT DOORS FROM EXISTING HOTEL SECOND LEVEL . 4. NEW UPPER LEVEL CANOPY WITH POSSIBLE SOLAR PANELS TO POSSIBLY OCCUR DEPENDING ON COSTS. SPECIFIC DRAWING NOTES: 1. NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS FOR THE NEW CONSTRUCTION/EXISTING BUILDING INTERSECTION JOINTS WITH THE NEW ROOFTOP DECK/COVERED ENTRY AND SURROUNDING GUARDRAIL WALLS PLUS THE POSSIBLE NEW CURVED UPPER ROOF. 2. NEW TEXTURED AND PAINTED 5/8”TYPE "X" DRYWALL ROOFTOP DECK/COVERED ENTRY SOFFIT WITH NEW RECEDED LIGHTING. 3. NEW, TOP LEVEL SOLID LOW WALL GUARDRAILING SURROUND AT NEW ROOFTOP DECK 42”HIGH MINIMUM ABOVE FINISHED ROOFTOP DECK. 4. NEW STEEL STUD SOLID GUARDRAIL FOR NEW ROOFTOP DECK WITH 5/8”APA SHEATHING AND STUCCO SYSTEM SIMILAR TO EXISTING BUILDING STUCCO.PROVIDE SLOPED METAL CAP AT TOP OF WALL ATTACHED TO THE TOP SIDES OF THE NEW GUARDRAILING WALL, TYPICAL. 5. PROVIDE GHOSTSHIELD WEAR-TEK 4400 URETHANE CONCRETE COATING (855-573-8383) OR EQUIVALENT OVER CONCRETE.INSTALL PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS.CLEAR FINISH, VERIFY WITH OWNER. 6. PAINTED EXTENDED STEEL ANGLE. 7. PROVIDE LONG LIFE WATERPROOF SEALANT AT INTERSECTION OF STEEL ANGLE AND CONCRETE. 8. 5/8”GYPSUM BOARD OVER HAT CHANNEL BELOW BOTTOM OF BAR JOISTS. 9. STUCCO SYSTEM OVER ATTACHED 5/8”APA SHEATHING.INSTALL STUCCO SYSTEM PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. 10. SLOPED PREFINISHED METAL CAP OVER TAPERED BLOCKING ATTACHED AT SIDES. 11. PROVIDE RECESSED DRIP, TYPICAL. 12. SLOPED CONCRETE WITH BROOM FINISH.VERIFY CONCRETE FINISH WITH OWNER. 1 1 1 1 No. Description Date 1 Plan Review Comments 2020-03-13 1 1 AA 2 2 13' - 0"13' - 0" 8' - 0 " 40 ' - 0 " BB1' - 4 " DD 3' - 2 " 3' - 6 " 3' - 6"3' - 6" 26' - 0" 2' - 8 " CC 7,545.22'7,545.22' 0'2'4'8'12' SCALE: 1/8" = 1'-0" 1 1 AA 2 2 BB DD CC 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 12 ' - 1 0 3 / 4 " 12 ' - 9 5 / 8 " A B DC +/- 82' - 0" 50' - 0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 3 7 A M A110 FLOOR PLAN & ELEVATIONS (EXISTING) T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A110 1 1ST LEVEL EXSITING PLAN 1/8" = 1'-0"A110 2 2ND LEVEL EXSITING ROOF PLAN 1/8" = 1'-0"A110 3 FRONT ELEVATION (EXSITING) 1/8" = 1'-0"A110 4 SIDE ELEVATION (EXSITING) 1" = 80'-0" GOOGLE MAP SITE PLAN No. Description Date 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A300 4 A300 A A300 2 A121 3 A121 DECK AREA 2 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A121 3 A121 Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 3 8 A M A111 FLOOR PLAN (EXISTING) Checker Author 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A111 2 2ND LEVEL PROPOSED PLAN W/ EXISTING LAYOUT 1/8" = 1'-0"A111 1 1ST LEVEL PROPOSED PLAN W/ EXISTING LAYOUT 1 ROUTE OFF OF DECK AREA No. Description Date 1 Plan Review Comments 2020-03-13 2 ASI 01 2020-04-13 EXIT PATH THROUGH THE INTERIOR OF THE EXISTING BUILDING REMOVED 2 UPUP 1 1 AA 2 2 BB DD CC 1 A300 1 A300 26' - 0" 2 A300 6' - 0 " 4' - 4 " 37 ' - 0 " 3' - 0 " CONCRETE PAD SEE STRUCT. HEATED DOWNSPOUT HEATED DOWNSPOUT 3' - 2 1/2" 1' - 9 1 / 4 " 8" 1' - 6" STEEL TUBE COLUMN EXISTING CANOPY ROOF LINE PROPOSED NEW COLUMN BASE (CLOSEST SPOT TO PROPERTY LINE) EX I S T I N G + / - 8 2 ' T O PR O P E R T Y L I N E PR O P O S E D + 8 0 ' T O PR O P E R T Y L I N E 2 A121 3 A121 1 ? 2 2 1 1 AA 2 2 BB DD CC 1 A300 A1204 DECK AREA +/-1,418 SF 1/ 8 " / 1 2 " 1/ 8 " / 1 2 " 2 A300 2 A300 DECK 4 A300 TRENCH DRAIN STEEL COLUMN ON RAISED CONCRETE SLAB STEEL COLUMN ON RAISED CONCRETE SLAB 27' - 0"27' - 0"13' - 0"13' - 0" 3' - 6"26' - 0"3' - 6" 8' - 0 " 37 ' - 0 " 3' - 0 " 10' - 0" 8' - 0" 6' - 0" A A300 1 RE: ESA REVIEW NOTES OF SHOP DRAWING SUBMITTAL AS IT RELATES TO HARDWARE 1 4' - 0 " ACCESSIBLE STAIRS A MINIMUM 48" CLEAR BETWEEN HANDRAILS PER 2015 IBC SECTION 1009.3 1 1 48" MIN.1 2 A121 3 A121 A1293 4' - 0 " ACCESSIBLE STAIRS A MINIMUM 48" CLEAR BETWEEN HANDRAILS PER 2015 IBC SECTION 1009.3 48" MIN. 4' - 8 1 / 4 " EQ EQ 1 40' - 0"40' - 0" 2 2 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 1 A300 6' - 8 7 / 8 " 12 ' - 1 0 3 / 4 " 12 ' - 9 5 / 8 " 26' - 0" 10' - 9 5/8"11' - 4"35' - 10 1/2"11' - 4"10' - 10" 7,541.56' 7,543.5' 7,542.53' 30 ' - 0 " AVERAGE POINT BU I L D I N G H E I G H T L I M I T A T I O N 2 A121 ± 7,545.22' 1 2' - 0 " 4' - 6 7 / 8 " 7' - 7 3 / 4 " 3 6 ' - 2 1 / 2 " 2' - 0 " 4' - 6 7 / 8 " ± 37' - 6 13/32" 13' - 0"13' - 0" ± 1 ' - 1 0 5 / 8 " CENTER OF ARCHED PARAPET 34' - 0 1/2" ± 1 1 ' - 6 1 / 8 " T.O. 3X6 T&G WOOD ROOF DECKING TO T.O. PARAPET FRAMING ± 1 2 ' - 4 3 / 4 " T.O. ROOF TO T.O. PARAPET FRAMING A B DC 2 A300 4 A300 5' - 10" A A300 3 A121 1 4' - 6 7 / 8 " 2' - 0 " 0'2'4'8'12' SCALE: 1/8" = 1'-0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 4 1 A M A120 FLOOR PLAN & ELEVATIONS PROPOSED T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A120 1 1ST LEVEL PROPOSED PLAN 1/8" = 1'-0"A120 2 2ND LEVEL PROPOSED PLAN 1/8" = 1'-0"A120 3 FRONT ELEVATION (PROPOSED) 1/8" = 1'-0"A120 4 SIDE ELEVATION (PROPOSED) No. Description Date 1 Plan Review Comments 2020-03-13 2 ASI 01 2020-04-13 UP 1 1 AA 2 2 BB DD CC 1 A300 2 A300 4' - 0"26' - 0"4' - 0" 47 ' - 1 0 " 8' - 0 " 37 ' - 0 " 3' - 0 " 26' - 0" 48 ' - 0 " 4 A300 8' - 0 " 11 " / 1 2 " 11 " / 1 2 " 8" / 12" 8" / 1 2 " A A300 2 A121 3 A121 1 0'2'4'8'12' SCALE: 1/8" = 1'-0" 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" D SOFFIT 110' -3" C 4 A300 ± 5' - 1 1/4"± 4' - 11 1/2" 3 A121 4' - 0" ACCESSIBLE STAIRS A MINIMUM 48" CLEAR BETWEEN HANDRAILS PER 2015 IBC SECTION 1009.3 0'2'4'8'12' SCALE: 1/4" = 1'-0" 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" 1 SOFFIT 110' -3" 2 A121 ± 27' - 4 1/2" 80 " M I N . C L E A R CAIN DETACTION RAIL PER CODE 4' - 0" MIN. STAIR DIMENSIONS SHOWN FOR REFERENCE ONLY. EXACT ELEVATION OF STAIR LANDING TO BE FIELD VERIFIED. GC TO COORD. WITH FABRICATOR THE ACTUAL NUMBER OF RISERS AND FINAL DIMENSIONS INCLUDING THE EXTENT OF THE CAIN DETECTION RAIL. STAIRS SHALL MAINTAIN FULL COMPLIANCE WITH ANY AND ALL APPLICABLE CODES. 7" M A X . 11" TREADS 2 2 12" MIN. 11" 2 2 3- 7 / 8 " M A X . 3-7'8" MAX. 2 42" HEIGHT GUARD RAIL 36" HEIGHT 1 1/2" STEEL TUBE HANDRAIL 2 Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 4 2 A M A121 FLOOR PLAN & ELEVATIONS PROPOSED Checker Author 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A121 1 ROOF PLAN 1 1/4" = 1'-0"A121 2 STAIR TWO SECTION 1 1/4" = 1'-0"A121 3 STAIR TWO SECTION 2 No. Description Date 1 Plan Review Comments 2020-03-13 2 ASI 01 2020-04-13 50' - 0" GATHERING AREA +475 SF ACCESSIBLE ROUTE TO PUBLIC WAY Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 4 2 A M A122 SITE Checker Author 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1" = 40'-0"A122 1 SITE 1 No. Description Date 1 Plan Review Comments 2020-03-13 NOTE: THIS IS A BUILDERS SET OF DRAWINGS. OWNER AND BUILDER TO PROVIDE AND INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. BUILDERS SET OF PLANS 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A300 4 A300 5' - 0 " 16 ' - 0 " 16 ' - 0 " RECESSED LIGHTING FIXTURES A A300 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 2 A121 3 A121 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A300 4 A300 1' - 6 " 45 ' - 0 " 3' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 7' - 4 " 8" 4' - 0"26' - 0"4' - 0" 34' - 0" NOTE REMOVED AS PART OF ASI 01 1 1 2 2 2 0'2'4'8'12' SCALE: 1/8" = 1'-0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 4 3 A M A130 REFLECTED CEILING PLAN T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A130 1 1ST LEVEL REFLECTED CEILING PLAN 1/8" = 1'-0"A130 2 2ND LEVEL REFLECTED CEILING PLAN No. Description Date 1 Plan Review Comments 2020-03-13 2 ASI 01 2020-04-13 NOTE: REFER TO ELECTRICAL CD SHEETS BY JCAA CONSULATING ENGINEERS, LLC FOR LIGHTING TYPE & LOCATION. THE EXIT SIGN INTO THE BUILDING HAS BEEN DELETED ON THIS SHEET AS IT IS NO LONGER REQUIRED BY CODE 2 0'2'4'8'12' SCALE: 1/4" = 1'-0" 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" ABD SOFFIT 110' -3" C 5 1 / 2 " 1/8" / 12" 2 A300 TRENCH DRAINNEW SLOPED ROOF DECK TO TRENCH DRAIN NEW COLUMN NEW SLOPED ROOF DECK TO ALIGN WITH EXISTING INTERIOR 2ND FLOOR LEVEL 4 A300 7,545.22' 7' - 4"8' - 0"8' - 0"8' - 0"8' - 0"8' - 0" 1 3/4" 1' - 11 3/4" 1' - 6" 5 3/4" 5' - 6 " 1/8" / 12" MA X NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS FOR THE NEW CONSTRUCTION/EXISTING BUILDING INTERSECTION JOINTS WITH THE NEW ROOFTOP DECK/COVERED ENTRY AND SURROUNDING GUARDRAIL WALLS PLUS THE POSSIBLE NEW CURVED UPPER ROOF. NEW STEEL BEAM 30 ' - 0 " BU I L D I N G H E I G H T L I M I T A T I O N 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 5/8" TYPE "X" GYPSUM SHEATHING SOFFIT. PROVIDE TEXTURE FINISH & PAINT, REVIEW & VERIFY WITH OWNER FOR FINISHES & COLOR DROPPED SOFFIT. PROVIDE WATERTIGHT EXPANSION JOINT BETWEEN NEW ROOF DECK & EXISTING BUILDING WALL, TYPICAL. PROVIDE EXTENDED THRESHOLD @ NEW EXTERIOR STOREFRONT DOOR TO COVER WATER TIGHT EXPANSION JOINT. PROVIDE STEEL STUDS WALLS / FURRING FOR 5/8" TYPE "X" SHEATHING SOFFIT. PROVIDE STEEL STUDS WALLS / FURRING FOR 5/8" TYPE "X" SHEATHING SOFFIT. PROVIDE 5/8" APA SHEATHING OVER NEW ANGLED STEEL BRACING & SIDES. PROVIDE NEW ROOFING SYSTEM COMPATIBLE / SIMILAR TO EXISTING ROOFING. PROVIDE CONT. PREFINISHED METAL FLASHING & SEALANT AS REQUIRED. PROVIDE WATERTIGHT EXPANSION JOINT TO ACCOMADATE MOVEMENT BETWEEN EXISTING BUILDING WALL & NEW ROOF. 4' - 0" ACCESSIBLE STAIRS A MINIMUM 48" CLEAR BETWEEN HANDRAILS PER 2015 IBC SECTION 1009.3 1 - 1-1/2" MIN. CLEAR1 2' - 6" 4' - 8 1/4" 8' - 0" 9' - 8 3/4" 4' - 5 1/2" DIMENSION TO INTERIOR FACE OF STAIR STRINGER DIMENSION IN RED WERE ADDED AS PART OF THE VULCRAFT SUBMITTAL REVIEW -THESE DIMENSIONS DO NOT REFLECT ANY CHANGES MADE TO THE ITEMS BEING DIMENSIONED 2 2 3' - 0"37' - 0" ELEVATIONS OF NEW BEAM ALONG GRIDLINE C & EXISTING BEAM ALONG GRIDLINE B. BEAM ELEVATIONS TO BE BASED OFF OF EXISTING SECOND FLOOR ELEVATION NOTED AS 112'-9 5/8". NEW BEAM GRIDLINE C -TOP OF BEAM = 112' -2 3/4" 112' -9 5/8" -4" (SLAB THICKNESS) -2-1/2" (BAR JOIST SEAT) -3/8" (ASSEMBLY SLOPE) = 112' -2 3/4" EXISTING BEAM GRIDLINE B -TOP OF BEAM = 111' -10 1/8" 112' -9 5/8" -4" (SLAB THICKNESS) -2-1/2" (BAR JOIST SEAT) -5" (ASSEMBLY SLOPE) = 111' -10 1/8" EXISTING BEAM ALONG GRIDLINE B TO BE DROPPED AS REQUIRED TO GET TO THE SPECIFIED ELEVATION. CONTRACTOR TO COORDINATE THE MODIFICATION OF THE EXISTING COLUMNS AND THE RE-ATTACHMENT IN THE FIELD. COORDINATE WITH THE ARCHITECT / STRUCTURAL ENGINEER AS REQUIRED. 2 EXISTING BEAM ELEV. TO BE LOWERED -RE: NOTE BELOW & STRUCTURAL 2 NEW BEAM -RE: NOTE BELOW & STRUCTURAL 2 2 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 1 A300 26' - 0" 7,543.5' 1" 3' - 6" 4' - 0" 4' - 0" 3' - 6" 26' - 0" 13' - 0"13' - 0" 1' - 6 " 6 7 / 8 " 3 7 / 8 " M A X . 8' - 1 " 5 1 / 2 " 3 2 ' - 8 " 3 4 ' - 0 1 / 2 " 11" POSSIBLE SOLAR PANEL EPDM ROOF SYSTEM ON 3X6 T&G WOOD ROOF DECKING GLULAM BLOCKING SEE STRUCT. STEEL BEAM 3' - 0 " 42" HEIGHT GUARD RAIL 36" HEIGHT 1 1/2" STEEL TUBE HANDRAIL PROVIDE CONTINUOUS HANDRAIL AT EACH SIDE OF THE STAIR. HANDRAIL EXTENSION 11" AT BOTTOM. 12" AT TOP OF THE STAIRS. MAXIMUM SPACING BETWEEN VERTICAL STAIR BALUSTERS TO BE 3 7/8" . LANDING 4' - 0" MIN. 1 2ND LEVEL 112' -9 5/8" SOFFIT 110' -3" 8" SLOPED PREFINISHED METAL CAP OVER FIRE TREATED TAPERED BLOCKING ATTACHED AT SIDES STUCCO SYSTEM ATTACHED OVER 5/8" APA SHEATHING. INSTALL STUCCO SYSTEM PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. PROVIDE RECESSED DRIP. TYPICAL NEW TEXTURED AND PAINTED 5/8” DRYWALL ROOFTOP DECK/COVERED ENTRY SOFFIT WITH NEW RECEDED LIGHTING. 3 1 / 2 " SLOPED CONCRETE WITH BROOM FINISH. VERIFY CONCRETE FINISH WITH OWNER PROVIDE GHOSTSHIELD WEAR-TEK 4400 URETHANE CONCRETE COATING (855-573-8383) OR EQUIVALENT OVER CONCRETE. INSTALL PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. CLEAR FINISH, VERIFY WITH OWNER. PROVIDE LONG LIFE WATERPROOF SEALANT AT INTERSECTION OF STEEL ANGLE AND CONCRETE. NEW, TOP LEVEL SOLID LOW WALL GUARDRAIL SURROUND AT NEW ROOFTOP DECK 42” HIGH MINIMUM ABOVE FINISHED ROOFTOP DECK. PAINTED EXTENDED STEEL ANGLE. 5/8” GYPSUM BOARD OVER HAT CHANNEL BELOW BOTTOM OF BAR JOISTS. SLOPE. 2ND LEVEL 112' -9 5/8" 1 1 A300 8" 13' - 0" 8' - 0 1 / 8 " 3' - 6" +/ - 9 ' - 0 " EXISTING WINDOW OPENING EXISTING WINDOW HEADER HEIGHT 7' - 0 " 6' - 0"(2) 3'-0" DOORS A300 A Sim EQ EQ PROVIDE NEW WATER TIGHT FIXED STOREFRONT GLASS FRAME SILL AT EXISTING BUILDING WINDOW SILL AT EACH SIDE OF THE DOOR. Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 4/ 2 3 / 2 0 2 0 9 : 1 2 : 4 4 A M A300 BUILDING SECTIONS T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/4" = 1'-0"A300 1 PROPOSED SECTION 1 1/4" = 1'-0"A300 2 STAIR SECTION 1 1/2" = 1'-0"A300 A WALL SECTION A 1/4" = 1'-0"A300 4 STOREFRONT DOORS No. Description Date 1 Plan Review Comments 2020-03-13 2 ASI 01 2020-04-13 STRUCTURAL STEEL NOTES:CONCRETE NOTES AND SPECIFICATIONS: SEISMIC DESIGN DATA TABLE: GENERAL STRUCTURAL NOTES: FOUNDATION NOTES: GENERAL DESIGN DATA TABLE: SPECIAL STRUCTURAL INSPECTIONS: SPECIAL INSPECTOR JOB TASK LISTING: SPECIAL INSPECTOR JOB TASK LISTING (CONT.):WOOD FRAMING SPECIFICATIONS: DEFERED SUBMITTALS: Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :SN100 GENERAL STRUCTURAL NOTES T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No. Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 1 CITY COMMENTS 03-09-20 2 CITY COMMENTS 03-24-20 2 A B D C 1 2 FOUNDATION PLAN DETAILDETAILDETAIL Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S100 FOUNDATION PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No. Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 1 CITY COMMENTS 03-09-20 2 CITY COMMENTS 03-24-20 3 3 ASI-1 04-08-20 A B D C 1 2 DECK FRAMING PLAN DETAILDETAILDETAILDETAIL DETAIL A B A B 1 D C 2 DETAIL B A DETAIL 1 Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S200 DECK FRAMING PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No. Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 1 CITY COMMENTS 03-09-20 2 CITY COMMENTS 03-24-20 3 AST-1 04-08-20 3 3 3 3 3 ROOF FRAMING PLAN A B D C 1 2 DETAILDETAILDETAIL DETAIL Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S300 ROOF FRAMING PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No. Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 1 CITY COMMENTS 03-09-20 2 CITY COMMENTS 03-24-20 4 CITY COMMENTS 04-15-20 44 ISSUE SHEET NO. 01 - 2 - 2 0 2 0 P E R M I T S E T SHEET INDEXLEGEND SYMBOL DESCRIPTION INDICATES GROUNDGND 3 M MS J I H EM - - N 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. FINAL CONNECTIONS & ROUGH-IN REQUIREMENTS TO EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 3. CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 4. CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL REPORT DISCREPANCIES TO THE ARCHITECT AND INCLUDE IN HIS BID ALL COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 5. PROPOSED SUBSTITUTIONS OF ELECTRICAL EQUIPMENT OR REQUEST FOR "OR EQUAL" OR "APPROVED EQUAL" LISTING SHALL BE SUBMITTED TO ARCHITECT NOT LESS THAN TEN (10) WORKING DAYS PRIOR TO BID. 6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 7. WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 8. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 9. PROVIDE RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC. 10. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 11. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 12.WIRE SHALL BE COPPER, 75°C RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90°C RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30°C AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 14. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS OR EQUIPMENT. 15. SYSTEMS SHALL BE COMPLETE, OPERABLE AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC., SHALL BE CONNECTED AND OPERABLE. 16. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE), PULLBOXES, TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC., REQUIRED. BACKFILL TRENCHES TO 90% COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. 17. PROVIDE MAINTENANCE RECEPTACLE WITHIN 25'-0" OF ALL MECHANICAL OR MOTORIZED EQUIPMENT. 18. SEE MECHANICAL DRAWINGS FOR LOCATION OF MECHANICAL EQUIPMENT. PROVIDE SERVICE TO AND CONNECT EQUIPMENT AS REQUIRED. PROVIDE FUSES OR HACR-TYPE CIRCUIT BREAKERS FOR ALL AIR CONDITIONING EQUIPMENT SIZED IN ACCORDANCE WITH MANUFACTURER'S NAMEPLATE. 19. PROVIDE ENGRAVED NAMEPLATES ON, PANELBOARDS, DISCONNECT SWITCHES, ETC. INDICATING EQUIPMENT DESIGNATION (OR DESIGNATION OF EQUIPMENT SERVED) AND VOLTAGE. NAMEPLATES TO BE MECHANICALLY FASTENED. 20. PANEL DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. RACEWAYS IN SLAB-ON-GRADE OR BELOW GRADE SHALL BE SCHEDULE 40 PVC. TRANSITIONS FROM BELOW TO ABOVE GRADE SHALL BE WITH RIGID STEEL ELBOWS WITH P.V.C. JACKET OR APPROVED EQUAL PROTECTION. 22. EMT, NON-METALLIC AND FLEXIBLE METAL CONDUITS SHALL HAVE A CODE SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS REQUIRED. 23. FIRE ALARM, SOUND, TELEPHONE, COMPUTER, AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1" SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 24. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. 25. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS SHALL BE LISTED AS SUITABLE FOR 75°C. 26. RECEPTACLES INSTALLED OUTSIDE, ON THE BUILDING EXTERIOR OR ROOF, WITHIN 6' OF A SINK OR WATER COOLER CONNECTION, VENDING MACHINES, AND KITCHEN AREAS SHALL BE GFCI TYPE OR PROTECTED BY GFCI CIRCUIT BREAKER PER NEC 210.8. 27. ALL NEW EQUIPMENT SUCH AS SWITCHBOARDS, DISTRIBUTION BOARDS, DISCONNECT SWITCHES, TRANSFORMERS AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER. 28. ELECTRICAL CONTRACTOR SHALL SUBMIT 5 COPIES OF ALL ELECTRICAL EQUIPMENT AND LIGHT FIXTURES TO ENGINEER VIA GENERAL CONTRACTOR FOR APPROVAL PRIOR TO ORDERING. 29. ELECTRICAL CONTRACTOR TO PROVIDE FINAL CONNECTION OF OWNER FURNISHED EQUIPMENT. VERIFY EXACT REQUIREMENTS PRIOR TO ROUGH IN. 30. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD ENGINEERED FIRE ALARM SYSTEM MODIFIED FOR EXISTING FIRE ALARM SYSTEM INSTALLED. PROVIDE DEVICES, CONDUIT, WIRES, CABLE, PROGRAMMING AND TESTING AS DIRECTED BY EQUIPMENT MANUFACTURER AND LOCAL FIRE DEPARTMENT FOR A CODE COMPLIANT FIRE ALARM/DETECTION SYSTEM. MATERIALS, EQUIPMENT AND WORKMANSHIP SHALL MEET PREVAILING CODES. THE SYSTEM SHALL BE COMPLETE AND OPERABLE. SUBMIT ONE LINE DIAGRAM OF SYSTEM WITH SHOP DRAWINGS. ONE LINE SHALL SHOW DEVICES, CONDUIT, WIRE, CABLE SIZES AND BATTERY CALCULATIONS. EQUIPMENT TO BE NEW AND SHALL BE STAMPED, SIGNED, CALIBRATION AND TESTED BY FACTORY CERTIFIED TECHNICIAN. 31. HANDLE TIES SHALL BE PROVIDED FOR ALL MULTI-WIRED BRANCH CIRCUITS UNLESS INDIVIDUAL NEUTRAL CONDUCTORS ARE PROVIDED PER NEC 210.4(B) 32. FURNISH ALL MECHANICAL EQUIPMENT WITH FUSIBLE DISCONNECTS. THESE DISCONNECTS SHALL BE EQUIPPED WITH CLASS "R" FUSES 33. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN THE CONTRACT DOCUMNETS TO THE ATTENTION OF THE ARCHITECT VERBALLY AND IN WRITING. WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. SHEET DESCRIPTION ELECTRICAL COVER SHEET REFLECTED CEILING PLAN E001 E100 E200 ONE LINE DIAGRAM AND SCHEDULES GENERAL NOTES PNL INDICATES PANEL WP INDICATES WEATHER-PROOF (NEMA 3R) NON-FUSED DISCONNECT SWITCH - 30A, 3P, UNLESS NOTED OTHERWISE SURFACE MOUNTED PANELBOARD FUSED NEMA 3R DISCONNECT SWITCH MOTOR OUTLET HOMERUN CONDUIT - ARROW INDICATES QUANTITY OF CIRCUITS FLUORESCENT STRIP CONDUIT AND/OR WIRE CONCEALED IN WALL OR ABOVE CEILING FLUORESCENT TROFFER RECESSED/SURFACE DOWNLIGHT PENDANT MOUNTED LUMINAIRE WALL SCONCE RECESSED LED SWITCH 3 WAY SWITCH SWITCH OCCUPANCY SENSOR CEILING MOUNTED OCCUPANCY SENSOR RECEPTACLE GFI RECEPTACLE QUAD RECEPTACLE DUPLEX RECEPTACLE/TELE-DATA TELE-DATA OUTLET COAX OUTLET JUNCTION BOX PUSH BUTTON SMOKE DETECTOR HORN STROBE MANUAL PULL BOX COMBINATION BATTERY PACK EGRESS / EXIT LIGHT EM WALL SCONCE BATTERY BACK EGRESS LIGHT MECHANICAL EQUIPMENT - SEE HVAC AND PLUMBING DRAWINGS GROUND BUS & GROUND ELECTRODES CODES & DESIGN CRITERIA JURISDICTION: ELECTRICAL CODE: ESTES PARK, COLORADO 2017 NATIONAL ELECTRICAL CODE ENERGY CODE 2015 INTERNATIONAL ENERGYCONSERVATION CODE Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes. All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : C.B. T.L. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 2 0 - 0 1 - 2 4 No. Description Date p 303.985.3260 Wheat Ridge, CO 80033 4100 Wadsworth Blvd. JCAA #1 9 . 2 1 0 E001 ELECTRICAL COVER SHEET 03 - 1 0 - 2 0 2 0 R E V I E W C O M M E N T S E300 LIGHTING COMCHECK 1 1 1 2020-04-27 1 1 A 2 2 B D C AA AA AA AA AA AA AA HE-8 PART 2 1 1 A 2 2 B D C HE-10 3 CC CC CC CC CC CC CC CC CC 4 4 4 4 4 4 4 4 4 6 6 1ST LEVEL 100' - 0" 2ND LEVEL 112' - 9 5/8" TOP of ROOF 125' - 8 3/8" 1 2 SOFFIT 110' - 3" HE-8 PART 1 BB HE-8 PART 1 BB STEP LIGHTING TO BE CONTROLLED VIA PHOTOCELL. DRIVE UP CANOPY TO BE CONTROLLED VIA PHOTOCELL. DIMMER SWITCH TO CONTROL UPPER CANOPY LIGHTING. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. PENDANT LUMINAIRES TO BE MOUNTED BELOW STRUCTURAL BEAMS. VERIFY HEIGHT OF STRUCTURAL BEAM PRIOR TO ROUGH-IN. NOT USED. NEW EXIT LIGHT TO MATCH BUILDING STANDARD. SHEET NOTES GENERAL NOTES 1. ALL WIRING TO BE 2#12CU#12CU GND- 12"C UNLESS OTHERWISE NOTED 2. INTERCONNECT EGRESS/EMERGENCY LIGHTING TO LOCAL UNSWITCHED LIGHTING CIRCUIT. 1 Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes. All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : C.B. T.L. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 2 0 - 0 1 - 2 4 No. Description Date p 303.985.3260 Wheat Ridge, CO 80033 4100 Wadsworth Blvd. JCAA #1 9 . 2 1 0 E100 REFLECTED CEILING PLAN 1/8" = 1'-0"E100 2 1ST LEVEL REFLECTED CEILING PLAN 1/8" = 1'-0"E100 1 2ND LEVEL REFLECTED CEILING PLAN 1/8" = 1'-0"E100 3 STEP LIGHTING ELEVATION 2 3 4 5 6 2020-04-27 1 1 2 SCALE: N.T.S. FOR REFERENCE ONLY, NO NEW WORK REQUIRED1EXISTING PARTIAL ONE LINE DIAGRAM Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes. All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : C.B. T.L. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 2 0 - 0 1 - 2 4 No. Description Date p 303.985.3260 Wheat Ridge, CO 80033 4100 Wadsworth Blvd. JCAA #1 9 . 2 1 0 EXISTING LOCATION: PANEL: HE VOLTAGE:480 /277 3Ø 4W CIRCUIT CODE: BUS: 400 DATE:1/23/20 4:06 PM MAINS: L.O. MOUNTING: SURFACE JOB: ROCKY MOUNTAIN HOTEL FULLY RATED AIC: 14,000 NEMA 1 ENCLOSURE CK T N O CO D E TR I P PO L E LOAD DESIGNATION C O N N E C T E D V A LOAD DESIGNATION TR I P PO L E CO D E CK T N O DESCRIPTION (NOTE)ØA ØB ØC A B C ØA ØB ØC (NOTE) DESCRIPTION 1 20 1 ROOM #2 HEATER 275 -• -MERC. UAP LITES REAR AND SIDE 20 1 2 3 20 1 HALL HEATER -•-MERC - VAP ISLAND LITES 20 1 4 5 20 1 SPARE - •-MERC VAP LITES REAR AND SIDE 20 1 6 7 20 1 RM #3 HEATER / AC EAST -•406 NEW ENTRY DRIVE UP / STPE LTS 20 1 L 8 9 20 1 RM #6 HEATER -•280 NEW UPPER CANOPYLIGHTING 20 1 L 10 11 20 1 RM #4 RM WEST HEATER - •-LIGHTS IN LAUNDRY ROOM 20 1 12 13 20 1 RM #4 EAST HEATER -• -HEATER 20 1 14 15 20 1 REM #5 HEATER -•-HEATER 20 1 16 17 20 1 RM #1 HEATER 273 - •-SPARE 20 1 18 19 20 1 SPARE -• - SPACE HEATER (KITCHEN STORE RM)40 20 21 20 1 LIGHTS IN MECHAICAL ROOM -•----22 23 20 1 HEATERS LAUNDRY ROOM - •-ELEVATOR 20 1 24 25 20 1 BT-1 OLD BAR AIR COND.-• -SPACE 26 27 SPACE -•-SPACE 28 29 SPACE - •-SPACE 30 31 SPACE -• -SPACE 32 33 SPACE -•-SPACE 34 35 SPACE - •-SPACE 36 37 SPACE -•75000 225 KVA STEP DOWN TRANSFORMER 225 O 38 39 SPACE -•75000 ---O 40 41 SPACE - •75000 ---3 O 42 PANEL NOTES:PHASE TOTALS PH A: 75406 PH B: 75280 PH C: 75000 TOTAL CONNECTED VA 225686 PANEL CONNECTED KVA 225.7 PANEL DEMAND KVA 225.9 PANEL DEMAND AMPS 271.7 Manufacturer: Type: PANEL HE LOAD CALCULATION LIGHTING 686 VOLTAMPS x 1.25 =858 VOLTAMPS RECEPTACLES - 1ST 10KVA 0 VOLTAMPS x 1.00 =0 VOLTAMPS RECEPTACLES - BALANCE 0 VOLTAMPS x 0.50 =0 VOLTAMPS LARGEST MOTOR LOAD 0 VOLTAMPS x 1.25 =0 VOLTAMPS BALANCE OF MOTOR LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS KITCHEN EQUIPMENT 0 VOLTAMPS x 0.65 =0 VOLTAMPS ELECTRIC HEATING EQUIPMENT 0 VOLTAMPS x 1.00 =0 VOLTAMPS MISC LOADS 225,000 VOLTAMPS x 1.00 =225,000 VOLTAMPS TOTAL CALCULATED DEMAND LOAD =225,858 VOLTAMPS 271.7 FULL LOAD AMPS L - LIGHTING K - KITCHEN R - RECEPTACLES H - ELECTRIC HEATING LM - LARGEST MOTOR O - MISCELLANEOUS M - MOTOR EXISTING LOCATION: PANEL: LE VOLTAGE:208 / 120 3Ø 4W CIRCUIT CODE: BUS: 100 DATE:12/30/19 1:34 PM MAINS: L.O. MOUNTING: SURFACE JOB: ROCKY MOUNTAIN HOTEL FULLY RATED AIC: 10,000 NEMA 1 ENCLOSURE CK T N O CO D E TR I P PO L E LOAD DESIGNATION C O N N E C T E D V A LOAD DESIGNATION TR I P PO L E CO D E CK T N O DESCRIPTION (NOTE)ØA ØB ØC A B C ØA ØB ØC (NOTE) DESCRIPTION 1 20 1 DRYER 110 SINGLE PHASE -• -MENS JOHN & RECEPTS DINING 20 1 2 3 20 1 RT-6 -•-SPARE 20 1 4 5 20 1 --- - •-BAR LIGHTS (4) DINING 20 1 6 7 20 1 BAR LIGHTS (EAST)-• - BAR LIGHTS (SOUTH WEST)20 1 8 9 20 1 BAND LIGHTS (STAGE)-•-FAN IN LAUNDRY 20 1 10 11 20 1 WNMS JOHN & 4 RECEPTS DINING - •-RECEPTS IN LAUNDRY ROOMS 20 1 12 13 20 1 SPARE -• -RECEPTS IN BAR 20 1 14 15 20 1 SPARE -•-RECEPTS GIFT SHOP (EAST 3)20 1 16 17 20 1 CONTROL RM HEATER - •-WASHING MACHINE 30 18 19 30 DRYER -• ----2 20 21 2 --- -•-SPACE 22 23 SPACE - •-SPACE 24 25 SPACE -• -SPACE 26 27 SPACE -•-SPACE 28 29 SPACE - •-SPACE 30 31 SPACE -• -SPACE 32 33 SPACE -•-SPACE 34 35 SPACE - •-SPACE 36 37 SPACE -• -SPACE 38 39 SPACE -•-SPACE 40 41 SPACE - •-SPACE 42 PANEL NOTES:PHASE TOTALS PH A: 0 PH B: 0 PH C: 0 TOTAL CONNECTED VA 0 PANEL CONNECTED KVA 0.0 PANEL DEMAND KVA 0.0 PANEL DEMAND AMPS 0.0 Manufacturer: Type: PANEL LE LOAD CALCULATION LIGHTING 0 VOLTAMPS x 1.25 =0 VOLTAMPS RECEPTACLES - 1ST 10KVA 0 VOLTAMPS x 1.00 =0 VOLTAMPS RECEPTACLES - BALANCE 0 VOLTAMPS x 0.50 =0 VOLTAMPS LARGEST MOTOR LOAD 0 VOLTAMPS x 1.25 =0 VOLTAMPS BALANCE OF MOTOR LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS KITCHEN EQUIPMENT 0 VOLTAMPS x 0.65 =0 VOLTAMPS ELECTRIC HEATING EQUIPMENT 0 VOLTAMPS x 1.00 =0 VOLTAMPS MISC LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS TOTAL CALCULATED DEMAND LOAD =0 VOLTAMPS 0.0 FULL LOAD AMPS L - LIGHTING K - KITCHEN R - RECEPTACLES H - ELECTRIC HEATING LM - LARGEST MOTOR O - MISCELLANEOUS M - MOTOR TO EXISTING PANELS EXISTING PANEL 'DB' TO BE LABELED CORRECTLY AT. TO BE 120/208V 3Ø SHEET NOTES 1 LUMINAIRE SCHEDULE DESIGNATION DESCRIPTION LAMPS VOLTAGE TOTAL VA MANUFACTURER MOUNTING REMARKSDESIGN BASIS OTHERSQTY.TYPE NAME CATALOG SERIES TYPE DEPTH AA SIX INCH RECESSED DOWNLIGHT LED UNV 54.0 HE WILLIAMS 6DR-TL-L60/840-UNV-O W-OF-CS-R RECESSED BB TEN INCH RECTANGULAR STEP LIGHT LED 277 14 HE WILLAMS S10-G0L3/840-FTGH-XX X-DIM-277 RECESSED VERIFY COLOR WITH ARCHITECT PRIOR TO ORDERING CC FOUR FOOT PENDANT MOUNT - RIGID STEM LED UNV 4.9 W/ft AXIS TB3DLED 600 80 3500 SO 4 C UNV DP 1 SA PENDANT 18"POWDER COAT FINISH TO BE DETERMINED AT LATER DATE. E200 ONE LINE DIAGRAM AND PANEL SCHEDULES 2 FUTURE SOLAR SYSTEM TO BE INSTALLED AT A LATER DATE. SOLAR TO BE CONNECTED TO MAIN GEAR. SOLAR DESIGN TBD. GENERAL NOTES 1. 2020-04-27 2020-04-27