HomeMy WebLinkAboutPLANS 20-B-00017 Rocky Mountain Hotel Approved 1701 North Lake Ave 2020-04-28CONTRACTORS RESPONSIBILITIES
1. OWNER & BUILDER TO PROVIDE & INSTALL ALL ELEMENTS OF THE BUILDING
PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS.
2. ELECTRICAL & PLUMBING TO CONFORM TO THEIR CURRENT RESPECTIVE
CODES ADOPTED BY ANY AND ALL GOVERNING AGENCIES HAVING
JURISDICTION OVER THIS PROJECT.
3. ARCHITECTURAL DETAILS THAT SHOW OR INDICATE STRUCTURAL SYSTEMS
AND/OR COMPONENTS ARE FOR GENERAL REFERENCE ONLY. REFER TO
STRUCTURAL DRAWINGS FOR SYSTEM SPECIFICATIONS, DESIGN, LAYOUT,
ETC... RELATED TO THEIR TRADE.
4. THE CONTRACTOR SHALL VERIFY THAT THE BUILDING CODE
REQUIREMENTS, AS ADOPTED BY THE LOCAL MUNICIPALITY, HAVE BEEN
MET. ALL WORK CONTAINED WITHIN THESE DOCUMENTS SHALL CONFORM
TO ALL CODES, REGULATIONS, ORDINANCES, LAWS, PERMITS & CONTRACT
DOCUMENTS WHICH APPLY.
5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS,
INSPECTIONS, LICENSES AND APPROVALS ASSOCIATED WITH THIS PROJECT.
6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EQUIPMENT SIZES
AND LOCATIONS WITH PLUMBING, ELECTRICAL AND UTILITY COMPANIES.
7. THE CONTRACTOR MUST VERIFY THE BUILDING LAYOUT WITH THE
SURVEYOR PRIOR TO EXCAVATING THE FOUNDATIONS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW
CONSTRUCTION ON THE SITE.
8. THE CONTRACTOR MUST VERIFY THAT ALL DOORS, WALLS AND CEILINGS
BETWEEN THE EXISTING BUILDING & THE NEW ROOF TOP DECK / COVERED
ENTRY WITH POSSIBLE UPPER ROOF CANOPY MEET ALL FIRE AND SAFETY
CODES AND REGULATIONS.
9. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING ALL
EXISTING AND FINISH GRADES ON SITE.
10. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING
CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
11. THE CONTRACTOR AND THEIR SUBCONTRACTORS ARE RESPONSIBLE FOR
COMPLETING ALL THE WORK WITHIN THESE DOCUMENTS, UNLESS NOTED
OTHERWISE.
12. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING AND
FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, AC EQUIPMENT,
RECESSED ITEMS AND ALL OTHER ITEMS AS REQUIRED.
13. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND
PROTECTED TO PREVENT DAMAGE AND DETERIORATION.
14. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL
CONCEALED SPACES, VOIDS, ATTICS, ETC… VERIFY TYPE REQUIRED WITH
ARCHITECT PRIOR TO INSTALLATION.
15. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE
SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN
REVIEWED BY THE ARCHITECT AND/OR ENGINEER. ALL SUCH PORTIONS OF
THE WORK SHALL BE INSTALLED IN ACCORDANCE WITH REVIEWED SHOP
DRAWINGS AND SAMPLES.
16. THE CONTRACTOR SHALL CONFINE THEIR OPERATIONS ON THE SITE TO THE
AREAS PERMITTED BY THESE DOCUMENTS AND THE OWNER.
17. MOISTURE IS THE PREVALENT CAUSE OF MOLD GROWTH. GENERAL
CONTRACTOR AND SUBCONTRACTORS ARE TO BE PROACTIVE IN THE
MITIGATION OF MOISTURE DURING CONSTRUCTION.
STRUCTURAL CHANGES
1. ANY CHANGES IN THE FIELD TO THE STRUCTURAL PLANS SHALL RELIEVE
THE ARCHITECT AND STRUCTURAL ENGINEER FROM ANY CONSEQUENCES
WHICH MAY ARISE.
DISCREPANCIES
1. ANY DISCREPANCIES IN THE FIELD TO THE STRUCTURAL PLANS SHALL BE
REPORTED TO THE ARCHITECT IMMEDIATELY. ANY FAILURE TO REPORT
DISCREPANCIES SHALL RELIEVE THE ARCHITECT OF ANY CONSEQUENCES
WHICH MAY ARISE.
ELECTRICAL
1. THE ELECTRICAL SYSTEMS ARE DESIGN-BUILD.
MECHANICAL
1. THE PLUMBING SYSTEMS ARE DESIGN-BUILD.
2. ALL PLUMBING SYSTEMS TO BE DESIGNED & INSTALLED PER ALL
APPLICABLE GOVERNING CODES.
3. ALL PLUMBING SYSTEMS TO BE COORDINATED WITH RELATED AND
ADJACENT TRADES BOTH IN DESIGN & INSTALLATION.
NOTE: THIS IS A BUILDERS SET OF
DRAWINGS. OWNER AND BUILDER TO
PROVIDE AND INSTALL ALL ELEMENTS OF
THE BUILDING PER MANUFACTURER'S
SPECIFICATIONS & REQUIREMENTS.
BUILDERS SET OF PLANS
PROJECT SITE
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
3
5
A
M
A001
PROJECT COVER SHEET
T.J.
J.M.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
REM
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
PROJECT INFORMATIONBUILDERS NOTE
VICINITY MAP
PROJECT TEAM
A001 PROJECT COVER SHEET
A110 FLOOR PLAN & ELEVATIONS (EXISTING)
A111 FLOOR PLAN (EXISTING)
A120 FLOOR PLAN & ELEVATIONS PROPOSED
A121 FLOOR PLAN & ELEVATIONS PROPOSED
A122 SITE
A130 REFLECTED CEILING PLAN
A300 BUILDING SECTIONS
SN100 GENERAL STRUCTURAL NOTES
S100 FOUNDATION PLAN AND DETAILS
S200 DECK FRAMING PLAN AND DETAILS
S300 ROOF FRAMING PLAN AND DETAILS
E001 ELECTRICAL COVER SHEET
E100 REFLECTED CEILING PLAN
E200 ONE LINE DIAGRAMS AND PANEL SCHEDULES
E300 LIGHTING COMCHECK
SHEET INDEX
STRUCTURAL:
SURVEYOR:
GENERAL CONTRACTOR:
ARCHITECT:
ERIC SMITH ASSOCIATES, P.C.
1919 7TH STREET
BOULDER, CO 80302
303-442-5458
303-442-4745 FAX
PROJECT ARCHITECT: TOM JARMON
EMAIL: Tom@esapc.com
NOT TO SCALE
NORTH
AREA:
BUILDING PERMIT SET FOR:
ROCKY MOUNTAIN HOTEL
NEW ROOFTOP DECK /
COVERED ENTRY WITH
POSSIBLE UPPER ROOF CANOPY
APPLICABLE CODES:
• 2015 IBC(INTERNATIONAL BUILDING CODE)
• 2015 IMC (INTERNATIONAL MECHANICAL CODE)
• 2015 IPC (INTERNATIONAL PLUMBING CODE)
• 2015 IFGC (INTERVENTIONAL FUEL GAS CODE)
• 2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE)
• 2017 NEC (NATIONAL ELECTRICAL CODE), VERIFY
ZONING DISTRICT:ACCOMMODATIONS (A)
ROOF TOP DECK: +/-1,418 SF
ACCESSIBILITY:
PROVIDE ACCESSIBLE ACCESS WITH LOW
PROFILE THRESHOLD TO NEW ROOFTOP DECK/
COVERED ENTRY FROM EXISTING BUILDING 2ND
LEVEL @ NEW STOREFRONT DOOR.
FENESTRATION SCHEDULE
CLIMATE ZONE: 5B
NEW STOREFRONT
DOORS
2015 IECC MIN.
VALUES PROVIDED
U=0.77 U=0.77
OR BETTER
NOTE:
NEW 2ND LEVEL STOREFRONT DOORS TO MEET
2015 IECC SHGC DEPENDING ON ROOF
OVERHANG OF POSSIBLE UPPER ROOF CANOPY.
Advanced Hospitality Management LLC.
Kumar Merchant, Principal
6860 S Yosemite Ct #1404
Centennial, Co 80112.
Phone: 720-357-7960
E-mail:
kumar@advancedhospitalitymanagement.com
VAN HORN ENGINEERING & SURVEYING
LONNIE SHELDON
TIM NEARY
1043 FISH CREEK ROAD
ESTES PARK, CO 80517
OFFICE:(970) 586-9388
lonnie@vanhornengineering.com
tim@vanhornengineering.com
CODE ANALYSIS:
R-1 BUILDING OCCUPANCY FOR THE HOTEL.
TYPE IIIB NEW CANOPY CONSTRUCTION WITH
HEAVY TIMBER AT THE UPPER CANOPY ROOF.
A-3 OCCUPANCY AT THE NEW CANOPY WITH 1,418
NET SF WHICH DIVIDED BY 15 NET SF PER
OCCUPANT = 94.5 OCCUPANTS.
THE NEW CANOPY 2ND EXIT IS PROVIDED WITH
THE NEW EXTERIOR STAIR AT THE SOUTH END.
1701 NORTH LAKE AVE
ESTES PARK COLORADO 80517
LEGAL DESCRIPTION:
LOT 2 NORTH LAKE SUBDIVISION EP
OWNER:
ASTRA ENGINEERING INC.
MYRON L. JACOBSON, PE
7887 E. BELLEVIEW AVENUE, SUITE
1100
ENGLEWOOD, CO 80111
PHONE: (720) 767-4567
myron.astra@gmail.com
GREER CONSTRUCTION, INC.
BEN GREER, PRESIDENT
LEED AP
620 S. 44TH ST.
BOULDER, CO 80305
PHONE: 303-775-7974
ben@greer-construction.com
GENERAL NOTE
1. GENERAL CONTRACTOR TO VERIFY EXISTING HOTEL
BUILDING 2ND LEVEL ELEVATION TO COORDINATE THE
FINISHED ELEVATION OF THE NEW CONCRETE ROOFTOP
DECK ADA ACCESSIBILITY ACCESS ONTO THE NEW
ROOFTOP DECK SURFACE AT THE NEW HOTEL 2ND LEVEL
ROOFTOP DECK ACCESS DOOR LOW PROFILE ADA
ACCESSIBLE THRESHOLD.ALL BUILDING AND STEEL
ELEVATIONS TO DEVELOP FROM THIS RELATIONSHIP FROM
THE EXISTING 2ND FLOOR HOTEL FLOOR TO THE NEW
ROOFTOP DECK.
2. PROVIDE STUCCO REPAIR/PATCH AS REQUIRED AT ALL
NEW AND EXISTING LOCATIONS AS REQUIRED.
SCOPE OF WORK
SCOPE OF WORK TO INCLUDE
1. PORTION OF THE EXISTING PORTE-COCHERE SHALL BE
REMOVED AS REQUIRED FOR THE REMODEL. THE EXISTING
EXTERIOR COLUMNS SHALL REMAIN AND BE COORDINATED
WITH THE STRUCTURAL SECTION OF THE CONSTRUCTION
DRAWINGS.
2. NEW ROOF TOP DECK / COVERED ENTRY WITH EXTERIOR
STAIRS.
3. AND NEW STOREFRONT DOORS FROM EXISTING HOTEL
SECOND LEVEL .
4. NEW UPPER LEVEL CANOPY WITH POSSIBLE SOLAR PANELS
TO POSSIBLY OCCUR DEPENDING ON COSTS.
SPECIFIC DRAWING NOTES:
1. NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW
UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING
BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL
MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT
PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS
EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS
FOR THE NEW CONSTRUCTION/EXISTING BUILDING
INTERSECTION JOINTS WITH THE NEW ROOFTOP
DECK/COVERED ENTRY AND SURROUNDING GUARDRAIL WALLS
PLUS THE POSSIBLE NEW CURVED UPPER ROOF.
2. NEW TEXTURED AND PAINTED 5/8”TYPE "X" DRYWALL ROOFTOP
DECK/COVERED ENTRY SOFFIT WITH NEW RECEDED LIGHTING.
3. NEW, TOP LEVEL SOLID LOW WALL GUARDRAILING SURROUND
AT NEW ROOFTOP DECK 42”HIGH MINIMUM ABOVE FINISHED
ROOFTOP DECK.
4. NEW STEEL STUD SOLID GUARDRAIL FOR NEW ROOFTOP DECK
WITH 5/8”APA SHEATHING AND STUCCO SYSTEM SIMILAR TO
EXISTING BUILDING STUCCO.PROVIDE SLOPED METAL CAP AT
TOP OF WALL ATTACHED TO THE TOP SIDES OF THE NEW
GUARDRAILING WALL, TYPICAL.
5. PROVIDE GHOSTSHIELD WEAR-TEK 4400 URETHANE CONCRETE
COATING (855-573-8383) OR EQUIVALENT OVER
CONCRETE.INSTALL PER MANUFACTURER’S INSTRUCTIONS
AND SPECIFICATIONS.CLEAR FINISH, VERIFY WITH OWNER.
6. PAINTED EXTENDED STEEL ANGLE.
7. PROVIDE LONG LIFE WATERPROOF SEALANT AT INTERSECTION
OF STEEL ANGLE AND CONCRETE.
8. 5/8”GYPSUM BOARD OVER HAT CHANNEL BELOW BOTTOM OF
BAR JOISTS.
9. STUCCO SYSTEM OVER ATTACHED 5/8”APA
SHEATHING.INSTALL STUCCO SYSTEM PER MANUFACTURER’S
INSTRUCTIONS AND SPECIFICATIONS.
10. SLOPED PREFINISHED METAL CAP OVER TAPERED BLOCKING
ATTACHED AT SIDES.
11. PROVIDE RECESSED DRIP, TYPICAL.
12. SLOPED CONCRETE WITH BROOM FINISH.VERIFY CONCRETE
FINISH WITH OWNER.
1
1
1
1
No. Description Date
1 Plan Review Comments 2020-03-13
1
1
AA
2
2
13' - 0"13' - 0"
8'
-
0
"
40
'
-
0
"
BB1'
-
4
"
DD
3'
-
2
"
3'
-
6
"
3' - 6"3' - 6"
26' - 0"
2'
-
8
"
CC
7,545.22'7,545.22'
0'2'4'8'12'
SCALE: 1/8" = 1'-0"
1
1
AA
2
2
BB
DD
CC
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
TOP of ROOF
125' -8 3/8"
1 2
SOFFIT
110' -3"
12
'
-
1
0
3
/
4
"
12
'
-
9
5
/
8
"
A B DC
+/- 82' - 0"
50' - 0"
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
3
7
A
M
A110
FLOOR PLAN &
ELEVATIONS (EXISTING)
T.J.
J.M.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/8" = 1'-0"A110
1 1ST LEVEL EXSITING PLAN
1/8" = 1'-0"A110
2 2ND LEVEL EXSITING ROOF PLAN
1/8" = 1'-0"A110
3 FRONT ELEVATION (EXSITING)
1/8" = 1'-0"A110
4 SIDE ELEVATION (EXSITING)
1" = 80'-0"
GOOGLE MAP SITE PLAN
No. Description Date
1
1
AA
2
2
BB
DD
CC
1
A300
2
A300
2
A300
4
A300
A
A300
2
A121
3
A121
DECK AREA
2
1
1
AA
2
2
BB
DD
CC
1
A300
2
A300
2
A121
3
A121
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
3
8
A
M
A111
FLOOR PLAN (EXISTING)
Checker
Author
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/8" = 1'-0"A111
2 2ND LEVEL PROPOSED PLAN W/ EXISTING LAYOUT
1/8" = 1'-0"A111
1 1ST LEVEL PROPOSED PLAN W/ EXISTING LAYOUT
1
ROUTE OFF OF DECK AREA
No. Description Date
1 Plan Review Comments 2020-03-13
2 ASI 01 2020-04-13
EXIT PATH THROUGH THE INTERIOR OF THE EXISTING BUILDING REMOVED
2
UPUP
1
1
AA
2
2
BB
DD
CC
1
A300
1
A300
26' - 0"
2
A300
6'
-
0
"
4'
-
4
"
37
'
-
0
"
3'
-
0
"
CONCRETE PAD
SEE STRUCT.
HEATED
DOWNSPOUT
HEATED
DOWNSPOUT
3' - 2 1/2"
1'
-
9
1
/
4
"
8"
1' - 6"
STEEL TUBE
COLUMN
EXISTING CANOPY
ROOF LINE
PROPOSED NEW
COLUMN BASE
(CLOSEST SPOT
TO PROPERTY
LINE)
EX
I
S
T
I
N
G
+
/
-
8
2
'
T
O
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
O
S
E
D
+
8
0
'
T
O
PR
O
P
E
R
T
Y
L
I
N
E
2
A121
3
A121
1
?
2
2
1
1
AA
2
2
BB
DD
CC
1
A300
A1204
DECK AREA +/-1,418 SF
1/
8
"
/
1
2
"
1/
8
"
/
1
2
"
2
A300
2
A300
DECK
4
A300
TRENCH DRAIN
STEEL COLUMN ON
RAISED CONCRETE
SLAB
STEEL COLUMN ON RAISED
CONCRETE SLAB
27' - 0"27' - 0"13' - 0"13' - 0"
3' - 6"26' - 0"3' - 6"
8'
-
0
"
37
'
-
0
"
3'
-
0
"
10' - 0"
8' - 0"
6' - 0"
A
A300
1
RE: ESA REVIEW NOTES OF SHOP
DRAWING SUBMITTAL AS IT RELATES
TO HARDWARE
1
4'
-
0
"
ACCESSIBLE STAIRS A MINIMUM
48" CLEAR BETWEEN HANDRAILS
PER 2015 IBC SECTION 1009.3
1
1
48" MIN.1
2
A121
3
A121
A1293
4'
-
0
"
ACCESSIBLE STAIRS A MINIMUM
48" CLEAR BETWEEN HANDRAILS
PER 2015 IBC SECTION 1009.3
48" MIN.
4'
-
8
1
/
4
"
EQ
EQ
1
40' - 0"40' - 0"
2
2
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
TOP of ROOF
125' -8 3/8"
1 2
SOFFIT
110' -3"
1
A300
6'
-
8
7
/
8
"
12
'
-
1
0
3
/
4
"
12
'
-
9
5
/
8
"
26' - 0"
10' - 9 5/8"11' - 4"35' - 10 1/2"11' - 4"10' - 10"
7,541.56'
7,543.5'
7,542.53'
30
'
-
0
"
AVERAGE POINT
BU
I
L
D
I
N
G
H
E
I
G
H
T
L
I
M
I
T
A
T
I
O
N
2
A121
± 7,545.22'
1
2'
-
0
"
4'
-
6
7
/
8
"
7'
-
7
3
/
4
"
3
6
'
-
2
1
/
2
"
2'
-
0
"
4'
-
6
7
/
8
"
± 37' - 6 13/32"
13' - 0"13' - 0"
±
1
'
-
1
0
5
/
8
"
CENTER OF
ARCHED
PARAPET
34' - 0 1/2"
±
1
1
'
-
6
1
/
8
"
T.O. 3X6 T&G WOOD ROOF DECKING
TO T.O. PARAPET FRAMING
±
1
2
'
-
4
3
/
4
"
T.O. ROOF TO T.O.
PARAPET FRAMING
A B DC
2
A300
4
A300
5' - 10"
A
A300
3
A121
1
4'
-
6
7
/
8
"
2'
-
0
"
0'2'4'8'12'
SCALE: 1/8" = 1'-0"
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
4
1
A
M
A120
FLOOR PLAN &
ELEVATIONS PROPOSED
T.J.
J.M.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/8" = 1'-0"A120
1 1ST LEVEL PROPOSED PLAN
1/8" = 1'-0"A120
2 2ND LEVEL PROPOSED PLAN
1/8" = 1'-0"A120
3 FRONT ELEVATION (PROPOSED)
1/8" = 1'-0"A120
4 SIDE ELEVATION (PROPOSED)
No. Description Date
1 Plan Review Comments 2020-03-13
2 ASI 01 2020-04-13
UP
1
1
AA
2
2
BB
DD
CC
1
A300
2
A300
4' - 0"26' - 0"4' - 0"
47
'
-
1
0
"
8'
-
0
"
37
'
-
0
"
3'
-
0
"
26' - 0"
48
'
-
0
"
4
A300
8'
-
0
"
11
"
/
1
2
"
11
"
/
1
2
"
8" / 12"
8"
/
1
2
"
A
A300
2
A121
3
A121
1
0'2'4'8'12'
SCALE: 1/8" = 1'-0"
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
D
SOFFIT
110' -3"
C
4
A300
± 5' - 1 1/4"± 4' - 11 1/2"
3
A121
4' - 0"
ACCESSIBLE STAIRS
A MINIMUM 48" CLEAR
BETWEEN HANDRAILS
PER 2015 IBC
SECTION 1009.3
0'2'4'8'12'
SCALE: 1/4" = 1'-0"
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
1
SOFFIT
110' -3"
2
A121
± 27' - 4 1/2"
80
"
M
I
N
.
C
L
E
A
R
CAIN DETACTION RAIL PER CODE
4' - 0" MIN.
STAIR DIMENSIONS SHOWN FOR REFERENCE ONLY. EXACT ELEVATION OF STAIR
LANDING TO BE FIELD VERIFIED. GC TO COORD. WITH FABRICATOR THE ACTUAL
NUMBER OF RISERS AND FINAL DIMENSIONS INCLUDING THE EXTENT OF THE CAIN
DETECTION RAIL. STAIRS SHALL MAINTAIN FULL COMPLIANCE WITH ANY AND ALL
APPLICABLE CODES.
7"
M
A
X
.
11" TREADS
2
2
12" MIN.
11"
2
2
3-
7
/
8
"
M
A
X
.
3-7'8" MAX.
2
42" HEIGHT GUARD RAIL
36" HEIGHT 1 1/2" STEEL
TUBE HANDRAIL
2
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
4
2
A
M
A121
FLOOR PLAN &
ELEVATIONS PROPOSED
Checker
Author
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/8" = 1'-0"A121
1 ROOF PLAN
1
1/4" = 1'-0"A121
2 STAIR TWO SECTION 1
1/4" = 1'-0"A121
3 STAIR TWO SECTION 2
No. Description Date
1 Plan Review Comments 2020-03-13
2 ASI 01 2020-04-13
50' - 0"
GATHERING AREA +475 SF
ACCESSIBLE ROUTE TO PUBLIC WAY
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
4
2
A
M
A122
SITE
Checker
Author
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1" = 40'-0"A122
1 SITE
1
No. Description Date
1 Plan Review Comments 2020-03-13
NOTE: THIS IS A BUILDERS SET OF
DRAWINGS. OWNER AND BUILDER TO
PROVIDE AND INSTALL ALL ELEMENTS OF
THE BUILDING PER MANUFACTURER'S
SPECIFICATIONS & REQUIREMENTS.
BUILDERS SET OF PLANS
1
1
AA
2
2
BB
DD
CC
1
A300
2
A300
2
A300
4
A300
5'
-
0
"
16
'
-
0
"
16
'
-
0
"
RECESSED LIGHTING
FIXTURES
A
A300
5/8" TYPE "X" GYPSUM
SHEATHING DROPPED
SOFFIT.
5/8" TYPE "X" GYPSUM
SHEATHING DROPPED
SOFFIT.
2
A121
3
A121
1
1
AA
2
2
BB
DD
CC
1
A300
2
A300
2
A300
4
A300
1'
-
6
"
45
'
-
0
"
3'
-
0
"
8'
-
0
"
8'
-
0
"
8'
-
0
"
8'
-
0
"
8'
-
0
"
7'
-
4
"
8"
4' - 0"26' - 0"4' - 0"
34' - 0"
NOTE REMOVED AS PART OF ASI 01
1
1
2
2
2
0'2'4'8'12'
SCALE: 1/8" = 1'-0"
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
4
3
A
M
A130
REFLECTED CEILING PLAN
T.J.
J.M.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/8" = 1'-0"A130
1 1ST LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0"A130
2 2ND LEVEL REFLECTED CEILING PLAN
No. Description Date
1 Plan Review Comments 2020-03-13
2 ASI 01 2020-04-13
NOTE: REFER TO ELECTRICAL CD SHEETS BY JCAA CONSULATING ENGINEERS, LLC FOR
LIGHTING TYPE & LOCATION. THE EXIT SIGN INTO THE BUILDING HAS BEEN DELETED ON
THIS SHEET AS IT IS NO LONGER REQUIRED BY CODE
2
0'2'4'8'12'
SCALE: 1/4" = 1'-0"
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
TOP of ROOF
125' -8 3/8"
ABD
SOFFIT
110' -3"
C
5
1
/
2
"
1/8" / 12"
2
A300
TRENCH DRAINNEW SLOPED ROOF
DECK TO TRENCH DRAIN
NEW COLUMN
NEW SLOPED ROOF DECK TO ALIGN WITH
EXISTING INTERIOR 2ND FLOOR LEVEL
4
A300
7,545.22'
7' - 4"8' - 0"8' - 0"8' - 0"8' - 0"8' - 0"
1 3/4"
1' - 11 3/4"
1' - 6"
5 3/4"
5'
-
6
"
1/8" / 12"
MA
X
NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING
BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT
PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS
FOR THE NEW CONSTRUCTION/EXISTING BUILDING INTERSECTION JOINTS WITH THE NEW ROOFTOP DECK/COVERED
ENTRY AND SURROUNDING GUARDRAIL WALLS PLUS THE POSSIBLE NEW CURVED UPPER ROOF.
NEW STEEL BEAM
30
'
-
0
"
BU
I
L
D
I
N
G
H
E
I
G
H
T
L
I
M
I
T
A
T
I
O
N
5/8" TYPE "X" GYPSUM
SHEATHING DROPPED SOFFIT.
5/8" TYPE "X" GYPSUM SHEATHING
SOFFIT. PROVIDE TEXTURE FINISH &
PAINT, REVIEW & VERIFY WITH OWNER
FOR FINISHES & COLOR
DROPPED SOFFIT.
PROVIDE WATERTIGHT EXPANSION JOINT
BETWEEN NEW ROOF DECK & EXISTING
BUILDING WALL, TYPICAL. PROVIDE
EXTENDED THRESHOLD @ NEW
EXTERIOR STOREFRONT DOOR TO
COVER WATER TIGHT EXPANSION JOINT.
PROVIDE STEEL STUDS WALLS / FURRING
FOR 5/8" TYPE "X" SHEATHING SOFFIT.
PROVIDE STEEL STUDS
WALLS / FURRING FOR 5/8"
TYPE "X" SHEATHING
SOFFIT.
PROVIDE 5/8" APA
SHEATHING OVER NEW
ANGLED STEEL BRACING &
SIDES. PROVIDE NEW
ROOFING SYSTEM
COMPATIBLE / SIMILAR TO
EXISTING ROOFING.
PROVIDE CONT. PREFINISHED
METAL FLASHING & SEALANT
AS REQUIRED.
PROVIDE WATERTIGHT
EXPANSION JOINT TO
ACCOMADATE MOVEMENT
BETWEEN EXISTING BUILDING
WALL & NEW ROOF.
4' - 0"
ACCESSIBLE STAIRS A
MINIMUM 48" CLEAR
BETWEEN HANDRAILS PER
2015 IBC SECTION 1009.3
1
-
1-1/2" MIN. CLEAR1
2' - 6"
4' - 8 1/4"
8' - 0"
9' - 8 3/4"
4' - 5 1/2"
DIMENSION TO INTERIOR
FACE OF STAIR STRINGER
DIMENSION IN RED WERE
ADDED AS PART OF THE
VULCRAFT SUBMITTAL
REVIEW -THESE DIMENSIONS
DO NOT REFLECT ANY
CHANGES MADE TO THE
ITEMS BEING DIMENSIONED
2
2
3' - 0"37' - 0"
ELEVATIONS OF NEW BEAM ALONG GRIDLINE C & EXISTING BEAM ALONG GRIDLINE B. BEAM ELEVATIONS TO
BE BASED OFF OF EXISTING SECOND FLOOR ELEVATION NOTED AS 112'-9 5/8".
NEW BEAM GRIDLINE C -TOP OF BEAM = 112' -2 3/4"
112' -9 5/8" -4" (SLAB THICKNESS) -2-1/2" (BAR JOIST SEAT) -3/8" (ASSEMBLY SLOPE) = 112' -2 3/4"
EXISTING BEAM GRIDLINE B -TOP OF BEAM = 111' -10 1/8"
112' -9 5/8" -4" (SLAB THICKNESS) -2-1/2" (BAR JOIST SEAT) -5" (ASSEMBLY SLOPE) = 111' -10 1/8"
EXISTING BEAM ALONG GRIDLINE B TO BE DROPPED AS REQUIRED TO GET TO THE SPECIFIED ELEVATION.
CONTRACTOR TO COORDINATE THE MODIFICATION OF THE EXISTING COLUMNS AND THE RE-ATTACHMENT IN
THE FIELD. COORDINATE WITH THE ARCHITECT / STRUCTURAL ENGINEER AS REQUIRED.
2
EXISTING BEAM
ELEV. TO BE
LOWERED -RE:
NOTE BELOW &
STRUCTURAL
2
NEW BEAM -RE: NOTE BELOW &
STRUCTURAL 2
2
1ST LEVEL
100' -0"
2ND LEVEL
112' -9 5/8"
TOP of ROOF
125' -8 3/8"
1 2
SOFFIT
110' -3"
1
A300
26' - 0"
7,543.5'
1"
3' - 6"
4' - 0"
4' - 0"
3' - 6"
26' - 0"
13' - 0"13' - 0"
1'
-
6
"
6
7
/
8
"
3
7
/
8
"
M
A
X
.
8'
-
1
"
5
1
/
2
"
3
2
'
-
8
"
3
4
'
-
0
1
/
2
"
11"
POSSIBLE SOLAR PANEL
EPDM ROOF SYSTEM
ON 3X6 T&G WOOD ROOF
DECKING
GLULAM BLOCKING SEE
STRUCT.
STEEL BEAM
3'
-
0
"
42" HEIGHT GUARD RAIL
36" HEIGHT 1 1/2" STEEL
TUBE HANDRAIL
PROVIDE CONTINUOUS
HANDRAIL AT EACH SIDE
OF THE STAIR.
HANDRAIL EXTENSION 11"
AT BOTTOM. 12" AT TOP
OF THE STAIRS.
MAXIMUM SPACING
BETWEEN VERTICAL
STAIR BALUSTERS
TO BE 3 7/8" .
LANDING 4' - 0" MIN.
1
2ND LEVEL
112' -9 5/8"
SOFFIT
110' -3"
8"
SLOPED PREFINISHED METAL CAP
OVER FIRE TREATED TAPERED
BLOCKING ATTACHED AT SIDES
STUCCO SYSTEM ATTACHED OVER 5/8"
APA SHEATHING. INSTALL STUCCO
SYSTEM PER MANUFACTURER’S
INSTRUCTIONS AND SPECIFICATIONS.
PROVIDE RECESSED
DRIP. TYPICAL
NEW TEXTURED AND PAINTED 5/8”
DRYWALL ROOFTOP
DECK/COVERED ENTRY SOFFIT
WITH NEW RECEDED LIGHTING.
3
1
/
2
"
SLOPED CONCRETE WITH
BROOM FINISH. VERIFY
CONCRETE FINISH WITH OWNER
PROVIDE GHOSTSHIELD WEAR-TEK
4400 URETHANE CONCRETE COATING
(855-573-8383) OR EQUIVALENT OVER
CONCRETE. INSTALL PER
MANUFACTURER’S INSTRUCTIONS
AND SPECIFICATIONS. CLEAR FINISH,
VERIFY WITH OWNER.
PROVIDE LONG LIFE WATERPROOF
SEALANT AT INTERSECTION OF
STEEL ANGLE AND CONCRETE.
NEW, TOP LEVEL SOLID LOW
WALL GUARDRAIL SURROUND
AT NEW ROOFTOP DECK 42”
HIGH MINIMUM ABOVE
FINISHED ROOFTOP DECK.
PAINTED EXTENDED STEEL
ANGLE.
5/8” GYPSUM BOARD OVER HAT
CHANNEL BELOW BOTTOM OF
BAR JOISTS.
SLOPE.
2ND LEVEL
112' -9 5/8"
1
1
A300
8"
13' - 0"
8'
-
0
1
/
8
"
3' - 6"
+/
-
9
'
-
0
"
EXISTING WINDOW OPENING
EXISTING WINDOW
HEADER HEIGHT
7'
-
0
"
6' - 0"(2) 3'-0" DOORS
A300
A
Sim EQ EQ
PROVIDE NEW WATER
TIGHT FIXED
STOREFRONT GLASS
FRAME SILL AT EXISTING
BUILDING WINDOW SILL
AT EACH SIDE OF THE
DOOR.
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-54
5
8
,
(
3
0
3
)
4
4
2
-47
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
4/
2
3
/
2
0
2
0
9
:
1
2
:
4
4
A
M
A300
BUILDING SECTIONS
T.J.
J.M.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
1
9
-
1
2
-
2
3
1/4" = 1'-0"A300
1 PROPOSED SECTION 1
1/4" = 1'-0"A300
2 STAIR SECTION
1 1/2" = 1'-0"A300
A WALL SECTION A
1/4" = 1'-0"A300
4 STOREFRONT DOORS
No. Description Date
1 Plan Review Comments 2020-03-13
2 ASI 01 2020-04-13
STRUCTURAL STEEL NOTES:CONCRETE NOTES AND SPECIFICATIONS:
SEISMIC DESIGN DATA TABLE:
GENERAL STRUCTURAL NOTES:
FOUNDATION NOTES:
GENERAL DESIGN DATA TABLE:
SPECIAL STRUCTURAL INSPECTIONS:
SPECIAL INSPECTOR JOB TASK LISTING:
SPECIAL INSPECTOR JOB TASK LISTING (CONT.):WOOD FRAMING SPECIFICATIONS:
DEFERED SUBMITTALS:
Sheet Number
Sheet Title
Project Phase
Astra Job No:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:SN100
GENERAL STRUCTURAL
NOTES
T.R.C.
ASTRA
12-16-2019
18-170
PROPOSED
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
PR
O
P
O
S
E
D
20
1
9
-
0
9
-
1
1
No. Description Date
E-Mail: ty.astra@gmail.com
Englewood, Colorado 80111
303-475-5691 Telephone
7887 E. Belleview Avenue, Suite 1100
1 CITY
COMMENTS 03-09-20
2 CITY
COMMENTS 03-24-20
2
A
B
D
C
1 2
FOUNDATION PLAN
DETAILDETAILDETAIL
Sheet Number
Sheet Title
Project Phase
Astra Job No:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:S100
FOUNDATION PLAN
AND DETAILS
T.R.C.
ASTRA
12-16-2019
18-170
PROPOSED
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
PR
O
P
O
S
E
D
20
1
9
-
0
9
-
1
1
No. Description Date
E-Mail: ty.astra@gmail.com
Englewood, Colorado 80111
303-475-5691 Telephone
7887 E. Belleview Avenue, Suite 1100
1 CITY
COMMENTS 03-09-20
2 CITY
COMMENTS 03-24-20
3
3 ASI-1 04-08-20
A
B
D
C
1 2
DECK FRAMING PLAN
DETAILDETAILDETAILDETAIL
DETAIL
A B A B 1 D C
2
DETAIL
B A
DETAIL
1
Sheet Number
Sheet Title
Project Phase
Astra Job No:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:S200
DECK FRAMING PLAN
AND DETAILS
T.R.C.
ASTRA
12-16-2019
18-170
PROPOSED
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
PR
O
P
O
S
E
D
20
1
9
-
0
9
-
1
1
No. Description Date
E-Mail: ty.astra@gmail.com
Englewood, Colorado 80111
303-475-5691 Telephone
7887 E. Belleview Avenue, Suite 1100
1 CITY
COMMENTS 03-09-20
2 CITY
COMMENTS 03-24-20
3 AST-1 04-08-20
3 3
3
3
3
ROOF FRAMING PLAN
A
B
D
C
1 2
DETAILDETAILDETAIL
DETAIL
Sheet Number
Sheet Title
Project Phase
Astra Job No:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates further
cooperation among the owner, his contractor and the
architect. Design and construction are complex.
Although the architect and his consultants have
performed their services with due care and diligence,
they cannot guarantee perfection. Communication is
imperfect and every contingency cannot be anticipated.
Any ambiguity or discrepancy discovered by the use of
these plans shall be reported immediately to the
architect. Failure to notify the architect compounds
misunderstanding and increases construction costs. A
failure to cooperate by a simple notice to the architect
shall relieve the architect from responsibility for the
consequences. Changes made from the plans without
consent of the architect are unauthorized and shall
relieve the architect of responsibility for all
consequences arriving out of such changes.
All design, documents and data prepared by Eric
Smith Associates, P.C. as instruments of service
shall remain property of Eric Smith Associates, P.C.
and shall not be copied, changed or disclosed in any
form whatsoever without first obtaining the express
written consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:S300
ROOF FRAMING PLAN
AND DETAILS
T.R.C.
ASTRA
12-16-2019
18-170
PROPOSED
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
PR
O
P
O
S
E
D
20
1
9
-
0
9
-
1
1
No. Description Date
E-Mail: ty.astra@gmail.com
Englewood, Colorado 80111
303-475-5691 Telephone
7887 E. Belleview Avenue, Suite 1100
1 CITY
COMMENTS 03-09-20
2 CITY
COMMENTS 03-24-20
4 CITY
COMMENTS 04-15-20
44
ISSUE
SHEET NO.
01
-
2
-
2
0
2
0
P
E
R
M
I
T
S
E
T
SHEET INDEXLEGEND
SYMBOL DESCRIPTION
INDICATES GROUNDGND
3
M
MS
J
I
H
EM
-
-
N
1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR
TO COMMENCEMENT OF WORK.
2. FINAL CONNECTIONS & ROUGH-IN REQUIREMENTS TO
EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED
WIRING DIAGRAMS, DETAILS AND INSTRUCTIONS. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS
AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY
SUPPLIED.
3. CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL,
MECHANICAL AND OTHER DRAWINGS PRIOR TO BID.
4. CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT
CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL REPORT
DISCREPANCIES TO THE ARCHITECT AND INCLUDE IN HIS BID
ALL COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING
CONDITIONS.
5. PROPOSED SUBSTITUTIONS OF ELECTRICAL EQUIPMENT OR
REQUEST FOR "OR EQUAL" OR "APPROVED EQUAL" LISTING
SHALL BE SUBMITTED TO ARCHITECT NOT LESS THAN TEN (10)
WORKING DAYS PRIOR TO BID.
6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO
THE SATISFACTION OF THE ARCHITECT.
7. WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE
LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND
ORDINANCES.
8. PROVIDE PERMITS AND INSPECTIONS REQUIRED.
9. PROVIDE RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL
INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS,
ALTERATIONS, REROUTINGS, ETC.
10. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY
OTHERS PRIOR TO ROUGH-IN.
11. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS
SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE
CORRECTIONS NECESSARY AT NO COST TO OWNER.
12.WIRE SHALL BE COPPER, 75°C RATED FOR GENERAL USE. FOR
HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT
BALLASTS WIRE SHALL BE COPPER, MINIMUM 90°C RATED. SIZES
INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30°C
AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR
HIGHER AMBIENT INSTALLATIONS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING
EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD
WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING
IN EQUIPMENT PROVIDED UNDER THIS SECTION.
14. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR
MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A
REASON TO SUBSTITUTE ALTERNATE MATERIALS OR
EQUIPMENT.
15. SYSTEMS SHALL BE COMPLETE, OPERABLE AND READY FOR
CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES,
MOTORS, ETC., SHALL BE CONNECTED AND OPERABLE.
16. VERIFY EXACT LOCATIONS OF EXISTING AND NEW
UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS
PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING,
BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS
(CONDUIT AND/OR WIRE), PULLBOXES, TRANSFORMER PADS,
SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC.,
REQUIRED. BACKFILL TRENCHES TO 90% COMPACTION AND
PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND
VERIFY EXACT UTILITY COMPANY DRAWINGS AND
REQUIREMENTS.
17. PROVIDE MAINTENANCE RECEPTACLE WITHIN 25'-0" OF ALL
MECHANICAL OR MOTORIZED EQUIPMENT.
18. SEE MECHANICAL DRAWINGS FOR LOCATION OF MECHANICAL
EQUIPMENT. PROVIDE SERVICE TO AND CONNECT EQUIPMENT
AS REQUIRED. PROVIDE FUSES OR HACR-TYPE CIRCUIT
BREAKERS FOR ALL AIR CONDITIONING EQUIPMENT SIZED IN
ACCORDANCE WITH MANUFACTURER'S NAMEPLATE.
19. PROVIDE ENGRAVED NAMEPLATES ON, PANELBOARDS,
DISCONNECT SWITCHES, ETC. INDICATING EQUIPMENT
DESIGNATION (OR DESIGNATION OF EQUIPMENT SERVED) AND
VOLTAGE. NAMEPLATES TO BE MECHANICALLY FASTENED.
20. PANEL DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER
CLEAR PLASTIC COVERS.
21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC
RACEWAYS. RACEWAYS IN SLAB-ON-GRADE OR BELOW GRADE
SHALL BE SCHEDULE 40 PVC. TRANSITIONS FROM BELOW TO
ABOVE GRADE SHALL BE WITH RIGID STEEL ELBOWS WITH P.V.C.
JACKET OR APPROVED EQUAL PROTECTION.
22. EMT, NON-METALLIC AND FLEXIBLE METAL CONDUITS SHALL
HAVE A CODE SIZED COPPER GROUNDING CONDUCTOR.
INCREASE CONDUIT SIZE AS REQUIRED.
23. FIRE ALARM, SOUND, TELEPHONE, COMPUTER, AND SIMILAR
SYSTEMS CONDUITS LARGER THAN 1" SHALL HAVE LONG
RADIUS SWEEPS (12 TIMES THE DIAMETER).
24. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR
LABELED BY U.L.
25. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT
BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL
APPARATUS SHALL BE LISTED AS SUITABLE FOR 75°C.
26. RECEPTACLES INSTALLED OUTSIDE, ON THE BUILDING
EXTERIOR OR ROOF, WITHIN 6' OF A SINK OR WATER COOLER
CONNECTION, VENDING MACHINES, AND KITCHEN AREAS SHALL
BE GFCI TYPE OR PROTECTED BY GFCI CIRCUIT BREAKER PER
NEC 210.8.
27. ALL NEW EQUIPMENT SUCH AS SWITCHBOARDS, DISTRIBUTION
BOARDS, DISCONNECT SWITCHES, TRANSFORMERS AND
PANELBOARDS SHALL BE BY THE SAME MANUFACTURER.
28. ELECTRICAL CONTRACTOR SHALL SUBMIT 5 COPIES OF ALL
ELECTRICAL EQUIPMENT AND LIGHT FIXTURES TO ENGINEER
VIA GENERAL CONTRACTOR FOR APPROVAL PRIOR TO
ORDERING.
29. ELECTRICAL CONTRACTOR TO PROVIDE FINAL CONNECTION OF
OWNER FURNISHED EQUIPMENT. VERIFY EXACT REQUIREMENTS
PRIOR TO ROUGH IN.
30. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD
ENGINEERED FIRE ALARM SYSTEM MODIFIED FOR EXISTING FIRE
ALARM SYSTEM INSTALLED. PROVIDE DEVICES, CONDUIT,
WIRES, CABLE, PROGRAMMING AND TESTING AS DIRECTED BY
EQUIPMENT MANUFACTURER AND LOCAL FIRE DEPARTMENT
FOR A CODE COMPLIANT FIRE ALARM/DETECTION SYSTEM.
MATERIALS, EQUIPMENT AND WORKMANSHIP SHALL MEET
PREVAILING CODES. THE SYSTEM SHALL BE COMPLETE AND
OPERABLE. SUBMIT ONE LINE DIAGRAM OF SYSTEM WITH SHOP
DRAWINGS. ONE LINE SHALL SHOW DEVICES, CONDUIT, WIRE,
CABLE SIZES AND BATTERY CALCULATIONS. EQUIPMENT TO BE
NEW AND SHALL BE STAMPED, SIGNED, CALIBRATION AND
TESTED BY FACTORY CERTIFIED TECHNICIAN.
31. HANDLE TIES SHALL BE PROVIDED FOR ALL MULTI-WIRED
BRANCH CIRCUITS UNLESS INDIVIDUAL NEUTRAL CONDUCTORS
ARE PROVIDED PER NEC 210.4(B)
32. FURNISH ALL MECHANICAL EQUIPMENT WITH FUSIBLE
DISCONNECTS. THESE DISCONNECTS SHALL BE EQUIPPED
WITH CLASS "R" FUSES
33. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS
WHICH MAY OCCUR IN THE CONTRACT DOCUMNETS TO THE
ATTENTION OF THE ARCHITECT VERBALLY AND IN WRITING.
WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE
PROCEEDING WITH THE WORK. THE CONTRACTOR WILL BE HELD
RESPONSIBLE FOR THE RESULTS OF ANY ERRORS,
DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS,
OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE
ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF
THE WORK.
SHEET DESCRIPTION
ELECTRICAL COVER SHEET
REFLECTED CEILING PLAN
E001
E100
E200 ONE LINE DIAGRAM AND SCHEDULES
GENERAL NOTES
PNL INDICATES PANEL
WP INDICATES WEATHER-PROOF (NEMA 3R)
NON-FUSED DISCONNECT SWITCH - 30A,
3P, UNLESS NOTED OTHERWISE
SURFACE MOUNTED PANELBOARD
FUSED NEMA 3R DISCONNECT SWITCH
MOTOR OUTLET
HOMERUN CONDUIT - ARROW INDICATES
QUANTITY OF CIRCUITS
FLUORESCENT STRIP
CONDUIT AND/OR WIRE CONCEALED IN
WALL OR ABOVE CEILING
FLUORESCENT TROFFER
RECESSED/SURFACE DOWNLIGHT
PENDANT MOUNTED LUMINAIRE
WALL SCONCE
RECESSED LED
SWITCH
3 WAY SWITCH
SWITCH OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR
RECEPTACLE
GFI RECEPTACLE
QUAD RECEPTACLE
DUPLEX RECEPTACLE/TELE-DATA
TELE-DATA OUTLET
COAX OUTLET
JUNCTION BOX
PUSH BUTTON
SMOKE DETECTOR
HORN STROBE
MANUAL PULL BOX
COMBINATION BATTERY PACK
EGRESS / EXIT LIGHT
EM WALL SCONCE
BATTERY BACK EGRESS LIGHT
MECHANICAL EQUIPMENT - SEE
HVAC AND PLUMBING DRAWINGS
GROUND BUS & GROUND ELECTRODES
CODES & DESIGN CRITERIA
JURISDICTION:
ELECTRICAL CODE:
ESTES PARK, COLORADO
2017 NATIONAL ELECTRICAL CODE
ENERGY CODE 2015 INTERNATIONAL ENERGYCONSERVATION CODE
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes.
All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
C.B.
T.L.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
2
0
-
0
1
-
2
4
No. Description Date
p 303.985.3260
Wheat Ridge, CO 80033
4100 Wadsworth Blvd.
JCAA
#1
9
.
2
1
0 E001
ELECTRICAL COVER
SHEET
03
-
1
0
-
2
0
2
0
R
E
V
I
E
W
C
O
M
M
E
N
T
S
E300 LIGHTING COMCHECK 1
1
1
2020-04-27
1
1
A
2
2
B
D
C
AA AA
AA AA
AA AA AA
HE-8
PART
2
1
1
A
2
2
B
D
C HE-10
3
CC CC
CC
CC CC
CC
CC CC
CC
4 4
4
4 4
4
4 4
4
6
6
1ST LEVEL
100' - 0"
2ND LEVEL
112' - 9 5/8"
TOP of ROOF
125' - 8 3/8"
1 2
SOFFIT
110' - 3"
HE-8
PART 1
BB
HE-8
PART 1
BB
STEP LIGHTING TO BE CONTROLLED VIA
PHOTOCELL.
DRIVE UP CANOPY TO BE CONTROLLED VIA
PHOTOCELL.
DIMMER SWITCH TO CONTROL UPPER CANOPY
LIGHTING. VERIFY EXACT LOCATION PRIOR TO
ROUGH-IN.
PENDANT LUMINAIRES TO BE MOUNTED BELOW
STRUCTURAL BEAMS. VERIFY HEIGHT OF
STRUCTURAL BEAM PRIOR TO ROUGH-IN.
NOT USED.
NEW EXIT LIGHT TO MATCH BUILDING
STANDARD.
SHEET NOTES
GENERAL NOTES
1. ALL WIRING TO BE 2#12CU#12CU GND-
12"C
UNLESS OTHERWISE NOTED
2. INTERCONNECT EGRESS/EMERGENCY
LIGHTING TO LOCAL UNSWITCHED
LIGHTING CIRCUIT.
1
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes.
All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
C.B.
T.L.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
2
0
-
0
1
-
2
4
No. Description Date
p 303.985.3260
Wheat Ridge, CO 80033
4100 Wadsworth Blvd.
JCAA
#1
9
.
2
1
0 E100
REFLECTED CEILING PLAN
1/8" = 1'-0"E100
2 1ST LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0"E100
1 2ND LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0"E100
3 STEP LIGHTING ELEVATION
2
3
4
5
6
2020-04-27
1 1
2
SCALE: N.T.S. FOR REFERENCE ONLY, NO NEW WORK REQUIRED1EXISTING PARTIAL ONE LINE DIAGRAM
Sheet Number
Sheet Title
Project Phase
Job Number:
Date:
Drawn By:
Checked By:
ER
I
C
S
M
I
T
H
A
S
S
O
C
I
A
T
E
S
,
P
.
C
.
19
1
9
S
E
V
E
N
T
H
S
T
R
E
E
T
BO
U
L
D
E
R
,
C
O
L
O
R
A
D
O
,
8
0
3
0
2
(3
0
3
)
4
4
2
-
5
4
5
8
,
(
3
0
3
)
4
4
2
-
4
7
4
5
F
A
X
NOTICE: DUTY OF COOPERATION
Release of these plans contemplates furthercooperation among the owner, his contractor and thearchitect. Design and construction are complex.Although the architect and his consultants haveperformed their services with due care and diligence,they cannot guarantee perfection. Communication isimperfect and every contingency cannot be anticipated.Any ambiguity or discrepancy discovered by the use ofthese plans shall be reported immediately to thearchitect. Failure to notify the architect compoundsmisunderstanding and increases construction costs. Afailure to cooperate by a simple notice to the architectshall relieve the architect from responsibility for theconsequences. Changes made from the plans withoutconsent of the architect are unauthorized and shallrelieve the architect of responsibility for allconsequences arriving out of such changes.
All design, documents and data prepared by EricSmith Associates, P.C. as instruments of serviceshall remain property of Eric Smith Associates, P.C.and shall not be copied, changed or disclosed in anyform whatsoever without first obtaining the expresswritten consent of Eric Smith Associates, P.C.
Eric Smith Associates, P.C.c
REVISIONS
DA
T
E
:
C.B.
T.L.
2019-12-23
19008
BUILDING PERMIT
17
0
1
N
L
A
K
E
A
V
E
ES
T
E
S
P
A
R
K
,
C
O
L
O
R
A
D
O
RO
C
K
Y
M
O
U
N
T
A
I
N
H
O
T
E
L
RE
M
O
D
E
L
BU
I
L
D
I
N
G
P
E
R
M
I
T
20
2
0
-
0
1
-
2
4
No. Description Date
p 303.985.3260
Wheat Ridge, CO 80033
4100 Wadsworth Blvd.
JCAA
#1
9
.
2
1
0
EXISTING LOCATION:
PANEL: HE
VOLTAGE:480 /277 3Ø 4W CIRCUIT CODE:
BUS: 400
DATE:1/23/20 4:06 PM MAINS: L.O. MOUNTING: SURFACE
JOB: ROCKY MOUNTAIN HOTEL FULLY RATED AIC:
14,000 NEMA 1 ENCLOSURE
CK
T
N
O
CO
D
E
TR
I
P
PO
L
E
LOAD DESIGNATION C O N N E C T E D V A LOAD DESIGNATION
TR
I
P
PO
L
E
CO
D
E
CK
T
N
O
DESCRIPTION (NOTE)ØA ØB ØC A B C ØA ØB ØC
(NOTE) DESCRIPTION
1 20 1 ROOM #2 HEATER 275 -• -MERC. UAP LITES REAR AND SIDE 20 1 2
3 20 1 HALL HEATER
-•-MERC - VAP ISLAND LITES 20 1 4
5 20 1 SPARE - •-MERC VAP LITES REAR AND SIDE 20 1 6
7 20 1 RM #3 HEATER / AC EAST -•406 NEW ENTRY DRIVE UP / STPE LTS 20 1 L 8
9 20 1 RM #6 HEATER -•280 NEW UPPER CANOPYLIGHTING 20 1 L 10
11 20 1 RM #4 RM WEST HEATER - •-LIGHTS IN LAUNDRY ROOM 20 1 12
13 20 1 RM #4 EAST HEATER -• -HEATER 20 1 14
15 20 1 REM #5 HEATER -•-HEATER 20 1 16
17 20 1 RM #1 HEATER 273 - •-SPARE 20 1 18
19 20 1 SPARE -• -
SPACE HEATER (KITCHEN STORE RM)40 20
21 20 1 LIGHTS IN MECHAICAL ROOM -•----22
23 20 1 HEATERS LAUNDRY ROOM - •-ELEVATOR 20 1 24
25 20 1 BT-1 OLD BAR AIR COND.-• -SPACE 26
27 SPACE -•-SPACE 28
29 SPACE - •-SPACE 30
31 SPACE -• -SPACE 32
33 SPACE -•-SPACE 34
35 SPACE - •-SPACE 36
37 SPACE -•75000 225 KVA STEP DOWN TRANSFORMER 225 O 38
39 SPACE -•75000 ---O 40
41 SPACE - •75000 ---3 O 42
PANEL NOTES:PHASE TOTALS PH A: 75406 PH B: 75280 PH C: 75000 TOTAL CONNECTED VA 225686
PANEL CONNECTED KVA 225.7
PANEL DEMAND KVA 225.9
PANEL DEMAND AMPS 271.7
Manufacturer:
Type:
PANEL HE LOAD CALCULATION
LIGHTING 686 VOLTAMPS x 1.25 =858 VOLTAMPS
RECEPTACLES - 1ST 10KVA 0 VOLTAMPS x 1.00 =0 VOLTAMPS
RECEPTACLES - BALANCE 0 VOLTAMPS x 0.50 =0 VOLTAMPS
LARGEST MOTOR LOAD 0 VOLTAMPS x 1.25 =0 VOLTAMPS
BALANCE OF MOTOR LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS
KITCHEN EQUIPMENT 0 VOLTAMPS x 0.65 =0 VOLTAMPS
ELECTRIC HEATING EQUIPMENT 0 VOLTAMPS x 1.00 =0 VOLTAMPS
MISC LOADS 225,000 VOLTAMPS x 1.00 =225,000 VOLTAMPS
TOTAL CALCULATED DEMAND LOAD =225,858 VOLTAMPS
271.7 FULL LOAD AMPS
L - LIGHTING K - KITCHEN
R - RECEPTACLES H - ELECTRIC HEATING
LM - LARGEST MOTOR O - MISCELLANEOUS
M - MOTOR
EXISTING LOCATION:
PANEL: LE
VOLTAGE:208 / 120 3Ø 4W CIRCUIT CODE:
BUS: 100
DATE:12/30/19 1:34 PM MAINS: L.O. MOUNTING: SURFACE
JOB: ROCKY MOUNTAIN HOTEL FULLY RATED AIC:
10,000 NEMA 1 ENCLOSURE
CK
T
N
O
CO
D
E
TR
I
P
PO
L
E
LOAD DESIGNATION C O N N E C T E D V A LOAD DESIGNATION
TR
I
P
PO
L
E
CO
D
E
CK
T
N
O
DESCRIPTION (NOTE)ØA ØB ØC A B C ØA ØB ØC
(NOTE) DESCRIPTION
1 20 1 DRYER 110 SINGLE PHASE -• -MENS JOHN & RECEPTS DINING 20 1 2
3 20 1 RT-6 -•-SPARE 20 1 4
5 20 1 ---
- •-BAR LIGHTS (4) DINING 20 1 6
7 20 1 BAR LIGHTS (EAST)-• -
BAR LIGHTS (SOUTH WEST)20 1 8
9 20 1 BAND LIGHTS (STAGE)-•-FAN IN LAUNDRY 20 1 10
11 20 1 WNMS JOHN & 4 RECEPTS DINING - •-RECEPTS IN LAUNDRY ROOMS 20 1 12
13 20 1 SPARE -• -RECEPTS IN BAR 20 1 14
15 20 1 SPARE -•-RECEPTS GIFT SHOP (EAST 3)20 1 16
17 20 1 CONTROL RM HEATER - •-WASHING MACHINE 30 18
19 30 DRYER -• ----2 20
21 2 ---
-•-SPACE 22
23 SPACE - •-SPACE 24
25 SPACE -• -SPACE 26
27 SPACE -•-SPACE 28
29 SPACE - •-SPACE 30
31 SPACE -• -SPACE 32
33 SPACE -•-SPACE 34
35 SPACE - •-SPACE 36
37 SPACE -• -SPACE 38
39 SPACE -•-SPACE 40
41 SPACE - •-SPACE 42
PANEL NOTES:PHASE TOTALS PH A: 0 PH B: 0 PH C: 0 TOTAL CONNECTED VA 0
PANEL CONNECTED KVA 0.0
PANEL DEMAND KVA 0.0
PANEL DEMAND AMPS 0.0
Manufacturer:
Type:
PANEL LE LOAD CALCULATION
LIGHTING 0 VOLTAMPS x 1.25 =0 VOLTAMPS
RECEPTACLES - 1ST 10KVA 0 VOLTAMPS x 1.00 =0 VOLTAMPS
RECEPTACLES - BALANCE 0 VOLTAMPS x 0.50 =0 VOLTAMPS
LARGEST MOTOR LOAD 0 VOLTAMPS x 1.25 =0 VOLTAMPS
BALANCE OF MOTOR LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS
KITCHEN EQUIPMENT 0 VOLTAMPS x 0.65 =0 VOLTAMPS
ELECTRIC HEATING EQUIPMENT 0 VOLTAMPS x 1.00 =0 VOLTAMPS
MISC LOADS 0 VOLTAMPS x 1.00 =0 VOLTAMPS
TOTAL CALCULATED DEMAND LOAD =0 VOLTAMPS
0.0 FULL LOAD AMPS
L - LIGHTING K - KITCHEN
R - RECEPTACLES H - ELECTRIC HEATING
LM - LARGEST MOTOR O - MISCELLANEOUS
M - MOTOR
TO EXISTING PANELS
EXISTING PANEL 'DB' TO BE
LABELED CORRECTLY AT. TO BE
120/208V 3Ø
SHEET NOTES
1
LUMINAIRE SCHEDULE
DESIGNATION DESCRIPTION
LAMPS
VOLTAGE TOTAL
VA
MANUFACTURER MOUNTING
REMARKSDESIGN BASIS
OTHERSQTY.TYPE NAME CATALOG
SERIES TYPE DEPTH
AA SIX INCH RECESSED DOWNLIGHT LED UNV 54.0 HE WILLIAMS 6DR-TL-L60/840-UNV-O
W-OF-CS-R RECESSED
BB TEN INCH RECTANGULAR STEP LIGHT LED 277 14 HE WILLAMS S10-G0L3/840-FTGH-XX
X-DIM-277 RECESSED
VERIFY COLOR WITH
ARCHITECT PRIOR TO
ORDERING
CC FOUR FOOT PENDANT MOUNT - RIGID STEM LED UNV 4.9 W/ft AXIS TB3DLED 600 80 3500
SO 4 C UNV DP 1 SA PENDANT 18"POWDER COAT FINISH TO BE
DETERMINED AT LATER DATE.
E200
ONE LINE DIAGRAM AND
PANEL SCHEDULES
2
FUTURE SOLAR SYSTEM TO BE
INSTALLED AT A LATER DATE.
SOLAR TO BE CONNECTED TO
MAIN GEAR. SOLAR DESIGN TBD.
GENERAL NOTES
1.
2020-04-27