HomeMy WebLinkAboutPLANS Rooftop Deck 1701 North Lake Ave 2019-12-02CONTRACTORS RESPONSIBILITIES 1. OWNER & BUILDER TO PROVIDE & INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. 2. ELECTRICAL & PLUMBING TO CONFORM TO THEIR CURRENT RESPECTIVE CODES ADOPTED BY ANY AND ALL GOVERNING AGENCIES HAVING JURISDICTION OVER THIS PROJECT. 3. ARCHITECTURAL DETAILS THAT SHOW OR INDICATE STRUCTURAL SYSTEMS AND/OR COMPONENTS ARE FOR GENERAL REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS FOR SYSTEM SPECIFICATIONS, DESIGN, LAYOUT, ETC... RELATED TO THEIR TRADE. 4. THE CONTRACTOR SHALL VERIFY THAT THE BUILDING CODE REQUIREMENTS, AS ADOPTED BY THE LOCAL MUNICIPALITY, HAVE BEEN MET. ALL WORK CONTAINED WITHIN THESE DOCUMENTS SHALL CONFORM TO ALL CODES, REGULATIONS, ORDINANCES, LAWS, PERMITS & CONTRACT DOCUMENTS WHICH APPLY. 5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS, INSPECTIONS, LICENSES AND APPROVALS ASSOCIATED WITH THIS PROJECT. 6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EQUIPMENT SIZES AND LOCATIONS WITH PLUMBING, ELECTRICAL AND UTILITY COMPANIES. 7. THE CONTRACTOR MUST VERIFY THE BUILDING LAYOUT WITH THE SURVEYOR PRIOR TO EXCAVATING THE FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE. 8. THE CONTRACTOR MUST VERIFY THAT ALL DOORS, WALLS AND CEILINGS BETWEEN THE EXISTING BUILDING & THE NEW ROOF TOP DECK / COVERED ENTRY WITH POSSIBLE UPPER ROOF CANOPY MEET ALL FIRE AND SAFETY CODES AND REGULATIONS. 9. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING ALL EXISTING AND FINISH GRADES ON SITE. 10. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 11. THE CONTRACTOR AND THEIR SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLETING ALL THE WORK WITHIN THESE DOCUMENTS, UNLESS NOTED OTHERWISE. 12. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, AC EQUIPMENT, RECESSED ITEMS AND ALL OTHER ITEMS AS REQUIRED. 13. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION. 14. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ETC… VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. 15. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT AND/OR ENGINEER. ALL SUCH PORTIONS OF THE WORK SHALL BE INSTALLED IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS AND SAMPLES. 16. THE CONTRACTOR SHALL CONFINE THEIR OPERATIONS ON THE SITE TO THE AREAS PERMITTED BY THESE DOCUMENTS AND THE OWNER. 17. MOISTURE IS THE PREVALENT CAUSE OF MOLD GROWTH. GENERAL CONTRACTOR AND SUBCONTRACTORS ARE TO BE PROACTIVE IN THE MITIGATION OF MOISTURE DURING CONSTRUCTION. STRUCTURAL CHANGES 1. ANY CHANGES IN THE FIELD TO THE STRUCTURAL PLANS SHALL RELIEVE THE ARCHITECT AND STRUCTURAL ENGINEER FROM ANY CONSEQUENCES WHICH MAY ARISE. DISCREPANCIES 1. ANY DISCREPANCIES IN THE FIELD TO THE STRUCTURAL PLANS SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY. ANY FAILURE TO REPORT DISCREPANCIES SHALL RELIEVE THE ARCHITECT OF ANY CONSEQUENCES WHICH MAY ARISE. ELECTRICAL 1. THE ELECTRICAL SYSTEMS ARE DESIGN-BUILD. MECHANICAL 1. THE PLUMBING SYSTEMS ARE DESIGN-BUILD. 2. ALL PLUMBING SYSTEMS TO BE DESIGNED & INSTALLED PER ALL APPLICABLE GOVERNING CODES. 3. ALL PLUMBING SYSTEMS TO BE COORDINATED WITH RELATED AND ADJACENT TRADES BOTH IN DESIGN & INSTALLATION. NOTE: THIS IS A BUILDERS SET OF DRAWINGS. OWNER AND BUILDER TO PROVIDE AND INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. BUILDERS SET OF PLANS PROJECT SITE Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 12 / 2 3 / 2 0 1 9 5 : 1 8 : 0 7 P M A001 PROJECT COVER SHEET T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 PROJECT INFORMATIONBUILDERS NOTE VICINITY MAP PROJECT TEAM A001 PROJECT COVER SHEET A110 FLOOR PLAN & ELEVATIONS (EXISTING) A120 FLOOR PLAN & ELEVATIONS PROPOSED A130 REFLECTED CEILING PLAN A300 BUILDING SECTIONS SN100 GENERAL STRUCTURAL NOTES S100 FOUNDATION PLAN AND DETAILS S200 DECK FRAMING PLAN AND DETAILS S300 ROOF FRAMING PLAN AND DETAILS SHEET INDEX STRUCTURAL: SURVEYOR: GENERAL CONTRACTOR: ARCHITECT: ERIC SMITH ASSOCIATES, P.C. 1919 7TH STREET BOULDER, CO 80302 303-442-5458 303-442-4745 FAX PROJECT ARCHITECT: TOM JARMON EMAIL: Tom@esapc.com NOT TO SCALE NORTH AREA: BUILDING PERMIT SET FOR: ROCKY MOUNTAIN HOTEL NEW ROOFTOP DECK / COVERED ENTRY WITH POSSIBLE UPPER ROOF CANOPY APPLICABLE CODES: • 2015 IBC(INTERNATIONAL BUILDING CODE) • 2015 IMC (INTERNATIONAL MECHANICAL CODE) • 2015 IPC (INTERNATIONAL PLUMBING CODE) • 2015 IFGC (INTERVENTIONAL FUEL GAS CODE) • 2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE) • 2015 NEC (NATIONAL ELECTRICAL CODE), VERIFY ZONING DISTRICT:ACCOMMODATIONS (A) ROOF TOP DECK: +/-1,418 SF ACCESSIBILITY: PROVIDE ACCESSIBLE ACCESS WITH LOW PROFILE THRESHOLD TO NEW ROOFTOP DECK/ COVERED ENTRY FROM EXISTING BUILDING 2ND LEVEL @ NEW STOREFRONT DOOR. FENESTRATION SCHEDULE CLIMATE ZONE: 5B NEW STOREFRONT DOORS 2015 IECC MIN. VALUES PROVIDED U=0.77 U=0.77 OR BETTER NOTE: NEW 2ND LEVEL STOREFRONT DOORS TO MEET 2015 IECC SHGC DEPENDING ON ROOF OVERHANG OF POSSIBLE UPPER ROOF CANOPY. Advanced Hospitality Management LLC. Kumar Merchant, Principal 6860 S Yosemite Ct #1404 Centennial, Co 80112. Phone: 720-357-7960 E-mail: kumar@advancedhospitalitymanagement.com VAN HORN ENGINEERING & SURVEYING LONNIE SHELDON TIM NEARY 1043 FISH CREEK ROAD ESTES PARK, CO 80517 OFFICE:(970) 586-9388 lonnie@vanhornengineering.com tim@vanhornengineering.com CODE ANALYSIS: R-1 BUILDING OCCUPANCY FOR THE HOTEL. TYPE IIIB NEW CANOPY CONSTRUCTION WITH HEAVY TIMBER AT THE UPPER CANOPY ROOF. A-3 OCCUPANCY AT THE NEW CANOPY WITH 1,418 NET SF WHICH DIVIDED BY 15 NET SF PER OCCUPANT = 94.5 OCCUPANTS. THE NEW CANOPY 2ND EXIT IS PROVIDED WITH THE NEW EXTERIOR STAIR AT THE SOUTH END. 1701 NORTH LAKE AVE ESTES PARK COLORADO 80517 LEGAL DESCRIPTION: LOT 2 NORTH LAKE SUBDIVISION EP OWNER: ASTRA ENGINEERING INC. MYRON L. JACOBSON, PE 7887 E. BELLEVIEW AVENUE, SUITE 1100 ENGLEWOOD, CO 80111 PHONE: (720) 767-4567 myron.astra@gmail.com GREER CONSTRUCTION, INC. BEN GREER, PRESIDENT LEED AP 620 S. 44TH ST. BOULDER, CO 80305 PHONE: 303-775-7974 ben@greer-construction.com GENERAL NOTE 1. GENERAL CONTRACTOR TO VERIFY EXISTING HOTEL BUILDING 2ND LEVEL ELEVATION TO COORDINATE THE FINISHED ELEVATION OF THE NEW CONCRETE ROOFTOP DECK ADA ACCESSIBILITY ACCESS ONTO THE NEW ROOFTOP DECK SURFACE AT THE NEW HOTEL 2ND LEVEL ROOFTOP DECK ACCESS DOOR LOW PROFILE ADA ACCESSIBLE THRESHOLD.ALL BUILDING AND STEEL ELEVATIONS TO DEVELOP FROM THIS RELATIONSHIP FROM THE EXISTING 2ND FLOOR HOTEL FLOOR TO THE NEW ROOFTOP DECK. 2. PROVIDE STUCCO REPAIR/PATCH AS REQUIRED AT ALL NEW AND EXISTING LOCATIONS AS REQUIRED. SCOPE OF WORK SCOPE OF WORK TO INCLUDE 1. NEW ROOF TOP DECK / COVERED ENTRY WITH EXTERIOR STAIRS. 2. AND NEW STOREFRONT DOORS FROM EXISTING HOTEL SECOND LEVEL . 3. NEW UPPER LEVEL CANOPY WITH POSSIBLE SOLAR PANELS TO POSSIBLY OCCUR DEPENDING ON COSTS. SPECIFIC DRAWING NOTES: 1. NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS FOR THE NEW CONSTRUCTION/EXISTING BUILDING INTERSECTION JOINTS WITH THE NEW ROOFTOP DECK/COVERED ENTRY AND SURROUNDING GUARDRAIL WALLS PLUS THE POSSIBLE NEW CURVED UPPER ROOF. 2. NEW TEXTURED AND PAINTED 5/8”TYPE "X" DRYWALL ROOFTOP DECK/COVERED ENTRY SOFFIT WITH NEW RECEDED LIGHTING. 3. NEW, TOP LEVEL SOLID LOW WALL GUARDRAILING SURROUND AT NEW ROOFTOP DECK 42”HIGH MINIMUM ABOVE FINISHED ROOFTOP DECK. 4. NEW STEEL STUD SOLID GUARDRAIL FOR NEW ROOFTOP DECK WITH 5/8”APA SHEATHING AND STUCCO SYSTEM SIMILAR TO EXISTING BUILDING STUCCO.PROVIDE SLOPED METAL CAP AT TOP OF WALL ATTACHED TO THE TOP SIDES OF THE NEW GUARDRAILING WALL, TYPICAL. 5. PROVIDE GHOSTSHIELD WEAR-TEK 4400 URETHANE CONCRETE COATING (855-573-8383) OR EQUIVALENT OVER CONCRETE.INSTALL PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS.CLEAR FINISH, VERIFY WITH OWNER. 6. PAINTED EXTENDED STEEL ANGLE. 7. PROVIDE LONG LIFE WATERPROOF SEALANT AT INTERSECTION OF STEEL ANGLE AND CONCRETE. 8. 5/8”GYPSUM BOARD OVER HAT CHANNEL BELOW BOTTOM OF BAR JOISTS. 9. STUCCO SYSTEM OVER ATTACHED 5/8”APA SHEATHING.INSTALL STUCCO SYSTEM PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. 10. SLOPED PREFINISHED METAL CAP OVER TAPERED BLOCKING ATTACHED AT SIDES. 11. PROVIDE RECESSED DRIP, TYPICAL. 12. SLOPED CONCRETE WITH BROOM FINISH.VERIFY CONCRETE FINISH WITH OWNER. No. Description Date 1 1 AA 2 2 13' - 0"13' - 0" 8' - 0 " 40 ' - 0 " BB1' - 4 " DD 3' - 2 " 3' - 6 " 3' - 6"3' - 6" 26' - 0" 2' - 8 " CC 7,544.92'7,544.92' 0'2'4'8'12' SCALE: 1/8" = 1'-0" 1 1 AA 2 2 BB DD CC 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 12 ' - 1 0 3 / 4 " 12 ' - 9 5 / 8 " A B DC +/- 82' - 0" 50' - 0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 12 / 2 3 / 2 0 1 9 5 : 1 8 : 1 0 P M A110 FLOOR PLAN & ELEVATIONS (EXISTING) T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A110 1 1ST LEVEL EXSITING PLAN 1/8" = 1'-0"A110 2 2ND LEVEL EXSITING ROOF PLAN 1/8" = 1'-0"A110 3 FRONT ELEVATION (EXSITING) 1/8" = 1'-0"A110 4 SIDE ELEVATION (EXSITING) 1" = 80'-0" GOOGLE MAP SITE PLAN No. Description Date 1 1 AA 2 2 BB DD CC 1 A300 1 A300 26' - 0" 2 A300 5' - 0 " 4' - 4 1 / 2 " 37 ' - 0 " 3' - 0 " CONCRETE PAD SEE STRUCT. HEATED DOWNSPOUT HEATED DOWNSPOUT 3' - 2 1/2" 7 1 / 2 " 8" 1' - 6" STEEL TUBE COLUMN 1' - 9 1 / 2 " EXISTING CANOPY ROOF LINE PROPOSED NEW COLUMN BASE (CLOSEST SPOT TO PROPERTY LINE) EX I S T I N G + / - 8 2 ' T O PR O P E R T Y L I N E PR O P O S E D + 8 0 ' T O PR O P E R T Y L I N E 1 1 AA 2 2 BB DD CC 1 A300 DECK AREA +/-1,418 SF 1/ 8 " / 1 2 " 1/ 8 " / 1 2 " 2 A300 2 A300 DECK 4 A300 TRENCH DRAIN STEEL COLUMN ON RAISED CONCRETE SLAB STEEL COLUMN ON RAISED CONCRETE SLAB 22' - 0"22' - 0"13' - 0"13' - 0" 3' - 6"26' - 0"3' - 6" 8' - 0 " 37 ' - 0 " 3' - 0 " 10' - 0" 8' - 0"6' - 0" A A300 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 1 A300 6' - 8 7 / 8 " 12 ' - 1 0 3 / 4 " 12 ' - 9 5 / 8 " 26' - 0" 5' - 10"5' - 10" 7,541.56' 7,543.5' 7,542.53' 30 ' - 0 " AVERAGE POINT BU I L D I N G H E I G H T L I M I T A T I O N A B DC 2 A300 4 A300 5' - 10" A A300 1 1 AA 2 2 BB DD CC 1 A300 2 A300 4' - 0"26' - 0"4' - 0" 47 ' - 1 0 " 8' - 0 " 37 ' - 0 " 3' - 0 " 26' - 0" 48 ' - 0 " 4 A300 8' - 0 " 11 " / 1 2 " 11 " / 1 2 " 8" / 12" 8" / 1 2 " 8" / 1 2 " 8" / 12" A A300 0'2'4'8'12' SCALE: 1/8" = 1'-0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 12 / 2 3 / 2 0 1 9 5 : 1 8 : 1 5 P M A120 FLOOR PLAN & ELEVATIONS PROPOSED T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A120 1 1ST LEVEL PROPOSED PLAN 1/8" = 1'-0"A120 2 2ND LEVEL PROPOSED PLAN 1/8" = 1'-0"A120 3 FRONT ELEVATION (PROPOSED) 1/8" = 1'-0"A120 4 SIDE ELEVATION (PROPOSED) 1/8" = 1'-0"A120 6 ROOF PLAN No. Description Date NOTE: THIS IS A BUILDERS SET OF DRAWINGS. OWNER AND BUILDER TO PROVIDE AND INSTALL ALL ELEMENTS OF THE BUILDING PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS. BUILDERS SET OF PLANS 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A300 4 A300 5' - 0 " 16 ' - 0 " 16 ' - 0 " RECESSED LIGHTING FIXTURES A A300 A A300 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 1 1 AA 2 2 BB DD CC 1 A300 2 A300 2 A300 4 A300 EQ EQ 10' - 0"10' - 0"1' - 1 0 " 1' - 1 0 " 8' - 0 " 37 ' - 0 " 3' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 7' - 4 " 8" 4' - 0"26' - 0"4' - 0" 34' - 0" 0'2'4'8'12' SCALE: 1/8" = 1'-0" Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 12 / 2 3 / 2 0 1 9 5 : 1 8 : 1 8 P M A130 REFLECTED CEILING PLAN T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/8" = 1'-0"A130 1 1ST LEVEL REFLECTED CEILING PLAN 1/8" = 1'-0"A130 2 2ND LEVEL REFLECTED CEILING PLAN No. Description Date 0'2'4'8'12' SCALE: 1/4" = 1'-0" 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" ABD SOFFIT 110' -3" C 5 1 / 2 " 1/8" / 12" 2 A300 TRENCH DRAIN NEW SLOPED ROOF DECK TO TRENCH DRAIN NEW COLUMN NEW SLOPED ROOF DECK TO ALIGN WITH EXISTING INTERIOR 2ND FLOOR LEVEL 8' - 0" 4 A300 7,544.92' 7' - 4"8' - 0"8' - 0"8' - 0"8' - 0"8' - 0" 10 5/8" 11 3/8" 1' - 6" 6 5/8" 5' - 6 " 1/8" / 12" MA X NEW ROOFTOP DECK/COVERED ROOF AND POSSIBLE NEW UPPER ROOF CANOPY TO NOT ATTACH TO THE EXISTING BUILDING PER STRUCTURAL LOADING AND DIFFERENTIAL MOVEMENT RELATED.PROVIDE EMSEAL OR EQUIVALENT PERMANENTLY ELASTIC WEATHERTIGHT CONTINUOUS EXPANSION JOINT INCLUDING ALL PRECOMPRESSED SEALANTS FOR THE NEW CONSTRUCTION/EXISTING BUILDING INTERSECTION JOINTS WITH THE NEW ROOFTOP DECK/COVERED ENTRY AND SURROUNDING GUARDRAIL WALLS PLUS THE POSSIBLE NEW CURVED UPPER ROOF. NEW STEEL BEAM 30 ' - 0 " BU I L D I N G H E I G H T L I M I T A T I O N 5/8" TYPE "X" GYPSUM SHEATHING DROPPED SOFFIT. 5/8" TYPE "X" GYPSUM SHEATHING SOFFIT. PROVIDE TEXTURE FINISH & PAINT, REVIEW & VERIFY WITH OWNER FOR FINISHES & COLOR DROPPED SOFFIT. PROVIDE WATERTIGHT EXPANSION JOINT BETWEEN NEW ROOF DECK & EXISTING BUILDING WALL, TYPICAL. PROVIDE EXTENDED THRESHOLD @ NEW EXTERIOR STOREFRONT DOOR TO COVER WATER TIGHT EXPANSION JOINT. PROVIDE STEEL STUDS WALLS / FURRING FOR 5/8" TYPE "X" SHEATHING SOFFIT. PROVIDE STEEL STUDS WALLS / FURRING FOR 5/8" TYPE "X" SHEATHING SOFFIT. PROVIDE 5/8" APA SHEATHING OVER NEW ANGLED STEEL BRACING & SIDES. PROVIDE NEW ROOFING SYSTEM COMPATIBLE / SIMILAR TO EXISTING ROOFING. PROVIDE CONT. PREFINISHED METAL FLASHING & SEALANT AS REQUIRED. PROVIDE WATERTIGHT EXPANSION JOINT TO ACCOMADATE MOVEMENT BETWEEN EXISTING BUILDING WALL & NEW ROOF. 1ST LEVEL 100' -0" 2ND LEVEL 112' -9 5/8" TOP of ROOF 125' -8 3/8" 1 2 SOFFIT 110' -3" 1 A300 26' - 0" 7,543.5' 1" 3' - 6" 4' - 0" 4' - 0" 3' - 6" 26' - 0" 13' - 0"13' - 0" 1' - 6 " 6 7 / 8 " 3 7 / 8 " M A X . 8' - 1 " 5 1 / 2 " 3 2 ' - 8 " 3 4 ' - 0 1 / 2 " 11" POSSIBLE SOLAR PANEL EPDM ROOF SYSTEM ON 3X6 T&G WOOD ROOF DECKING GLULAM BLOCKING SEE STRUCT. STEEL BEAM 11" 3' - 0 " 3' - 6 " 42" HEIGHT GUARD RAIL 36" HEIGHT 1 1/2" STEEL TUBE HANDRAIL PROVIDE CONTINUOUS HANDRAIL AT EACH SIDE OF THE STAIR. HANDRAIL EXTENSION 11" AT BOTTOM. 12" AT TOP OF THE STAIRS. MAXIMUM SPACING BETWEEN VERTICAL STAIR BALUSTERS TO BE 3 7/8" . 2ND LEVEL 112' -9 5/8" SOFFIT 110' -3" 8" SLOPED PREFINISHED METAL CAP OVER FIRE TREATED TAPERED BLOCKING ATTACHED AT SIDES STUCCO SYSTEM ATTACHED OVER 5/8" APA SHEATHING. INSTALL STUCCO SYSTEM PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. PROVIDE RECESSED DRIP. TYPICAL NEW TEXTURED AND PAINTED 5/8” DRYWALL ROOFTOP DECK/COVERED ENTRY SOFFIT WITH NEW RECEDED LIGHTING. 3 1 / 2 " SLOPED CONCRETE WITH BROOM FINISH. VERIFY CONCRETE FINISH WITH OWNER PROVIDE GHOSTSHIELD WEAR-TEK 4400 URETHANE CONCRETE COATING (855-573-8383) OR EQUIVALENT OVER CONCRETE. INSTALL PER MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS. CLEAR FINISH, VERIFY WITH OWNER. PROVIDE LONG LIFE WATERPROOF SEALANT AT INTERSECTION OF STEEL ANGLE AND CONCRETE. NEW, TOP LEVEL SOLID LOW WALL GUARDRAIL SURROUND AT NEW ROOFTOP DECK 42” HIGH MINIMUM ABOVE FINISHED ROOFTOP DECK. PAINTED EXTENDED STEEL ANGLE. 5/8” GYPSUM BOARD OVER HAT CHANNEL BELOW BOTTOM OF BAR JOISTS. SLOPE. 2ND LEVEL 112' -9 5/8" 1 1 A300 8" 13' - 0" 8' - 0 1 / 8 " 3' - 6" +/ - 9 ' - 0 " +/- 10' - 0" EXISTING WINDOW OPENING EXISTING WINDOW HEADER HEIGHT 7' - 0 " 6' - 0"(2) 3'-0" DOORS A300 A Sim EQ EQ PROVIDE NEW WATER TIGHT FIXED STOREFRONT GLASS FRAME SILL AT EXISTING BUILDING WINDOW SILL AT EACH SIDE OF THE DOOR. Sheet Number Sheet Title Project Phase Job Number: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 -54 5 8 , ( 3 0 3 ) 4 4 2 -47 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E : 12 / 2 3 / 2 0 1 9 5 : 1 8 : 2 0 P M A300 BUILDING SECTIONS T.J. J.M. 2019-12-23 19008 BUILDING PERMIT 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L BU I L D I N G P E R M I T 20 1 9 - 1 2 - 2 3 1/4" = 1'-0"A300 1 PROPOSED SECTION 1 1/4" = 1'-0"A300 2 STAIR SECTION 1 1/2" = 1'-0"A300 A WALL SECTION A 1/4" = 1'-0"A300 4 STOREFRONT DOORS No. Description Date STRUCTURAL STEEL NOTES:CONCRETE NOTES AND SPECIFICATIONS: SEISMIC DESIGN DATA TABLE: GENERAL STRUCTURAL NOTES: FOUNDATION NOTES: GENERAL DESIGN DATA TABLE: SPECIAL STRUCTURAL INSPECTIONS: SPECIAL INSPECTOR JOB TASK LISTING: SPECIAL INSPECTOR JOB TASK LISTING (CONT.):WOOD FRAMING SPECIFICATIONS: DEFERED SUBMITTALS: Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :SN100 GENERAL STRUCTURAL NOTES T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No.Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 A B D C 1 2 FOUNDATION PLAN DETAILDETAILDETAIL Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S100 FOUNDATION PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No.Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 A B D C 1 2 DECK FRAMING PLAN DETAILDETAILDETAILDETAIL DETAIL A B A B 1 D C 2 DETAIL B A Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S200 DECK FRAMING PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No.Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100 ROOF FRAMING PLAN A B D C 1 2 DETAILDETAILDETAIL DETAIL Sheet Number Sheet Title Project Phase Astra Job No: Date: Drawn By: Checked By: ER I C S M I T H A S S O C I A T E S , P . C . 19 1 9 S E V E N T H S T R E E T BO U L D E R , C O L O R A D O , 8 0 3 0 2 (3 0 3 ) 4 4 2 - 5 4 5 8 , ( 3 0 3 ) 4 4 2 - 4 7 4 5 F A X NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for the consequences. Changes made from the plans without consent of the architect are unauthorized and shall relieve the architect of responsibility for all consequences arriving out of such changes. All design, documents and data prepared by Eric Smith Associates, P.C. as instruments of service shall remain property of Eric Smith Associates, P.C. and shall not be copied, changed or disclosed in any form whatsoever without first obtaining the express written consent of Eric Smith Associates, P.C. Eric Smith Associates, P.C.c REVISIONS DA T E :S300 ROOF FRAMING PLAN AND DETAILS T.R.C. ASTRA 12-16-2019 18-170 PROPOSED 17 0 1 N L A K E A V E ES T E S P A R K , C O L O R A D O RO C K Y M O U N T A I N H O T E L RE M O D E L PR O P O S E D 20 1 9 - 0 9 - 1 1 No.Description Date E-Mail: ty.astra@gmail.com Englewood, Colorado 80111 303-475-5691 Telephone 7887 E. Belleview Avenue, Suite 1100