HomeMy WebLinkAboutPERMIT Canopy 1701 North Lake Ave 2020-01-07 Astra Engineering LLC July 25, 2019 Advanced Hospitality Management, LLC 6860 S. Yosemite Ct. #1404 Centennial, CO 80112 Attn: Kumar Merchant Re: Rocky Mountain Hotel & Conference Center 1701 N. Lake Ave. (Porte Cochere) Estes Park, CO 80517 Astra Engineering Project Number 19-154 Dear Mr. Merchant, Per your request, we completed a site visit at the property referenced above on July 18, 2019 for the purposes of performing a structural condition assessment of the damaged area of the existing Porte Cochere. It is our understanding that the reason for this assessment request is to evaluate the extent of the damage caused by a recent high-profile vehicle impact. FINDINGS: GENERAL: We observed that the main impact area is at the approximate mid-span of the leading edge of the Porte Cochere framing, at the east side approach area (see photos at the end of this report). Nearly all the non-structural fascia, sloped roof and soffit assembly along this edge is significantly damaged. The impact also caused irreversible damage to at least four (4) structural steel roof joist. Additional roof joists are likely be damaged due to steel bridging and steel decking attachments that extend into areas of the framing system which are not visible at this time. We did not observe any impact related damage to either of the two (2) steel columns or the column cover/finish materials. However, the steel column base plates should be inspected for sign of overstress once access to the base plate area is available. Similarly, the joist connections along the existing building should be evaluated once full access can be accomplished. RECOMMENDATIONS: OVERALL: Based on our site observations and review of available information we recommend the following: The four (4) leading edge joists along the east side of the Porte Cochere will need to be replaced entirely. As part of this replacement, the associated sections of steel deck and steel bridging will also need to be replaced. While not a structural element, the entire underside (soffit) of the Porte Cochere should be removed (and replaced) so that the extent of damage caused by bridging and decking movement can be assessed. The bridging and decking elements are part of the overall structural system and are rigidly attached to each steel joist. Any excessive movement in these elements can cause twisting in the joists or a weakening in joist lateral support systems necessary for proper joist performance. Once the soffit material is removed, an additional assessment should be accomplished to verify proper 7887 E. Belleview Avenue, Suite 1100 Englewood, CO 80111 Ph. 303-475-5691 connectivity of all structural elements.Furthermore, anevaluation of the steel column base plates and the steel joist connections at the building should be accomplishedwhen access to these areas is available. Please understand that this inspection was limited to visual observation only and that there is a possibility of structural issues that are not visually evident. If you have any questions regarding this letteror need any clarification, please feel free to contact the undersigned. Sincerely Tyrone R. Carter, PE Principle East side looking South East side looking North