DOCUMENT Firestop Methods B-8445 3501 Fall River Rd 2008-04-07
Fire stop methods for Della Terra Specified Technologies, Inc. 3TI'. PRODUCT DATA SHEET vrpecseabiaIk Series SSP Putty & Putty Pads p, FILL VOID OR CAVITY MATERIALS CLASSIFIED BY a UNDERWRITERS LABORATORIES INC. FOR USE IN THROUGH.PENETRATION FIRESTOP SYSTEMS. SEE UL FIRE RESISTANCE DIRECTORY 3L73 EWRS �IES EFIDALLL PRTECMATRIAL SEPRODUCT CATEGORY IN UL FIRE RESISTANCE DIRECTORY *S�CAVITY MAlERIALS Fo ORUSEINTHROUGH.EENNEIRATIONFIRESTOP SYSTEMS SEE UL DIRECTORY OF PRODUCTS CER1!FIEDFOR CCAANNADIDTANR AND UL FIRE RESTS• APPROVED FEATURES • Non -Hardening Easy retrofit! • Two Stage Intumescence features aggressive expansion. • Endothermic Fillers absorb heat & release water. • Highly Adhesive Formula Stays put. Allows movement. • Soft & Pliable for easy installation. • No Water -Soluble Expansion Ingredients means better water resistance! • Sound Deadening! Excellent sound attenuation properties. Reduces noise transmission. 1. PRODUCT DESCRIPTION SpecSeal® Series SSP Putty is a non -hardening, intumescent compound designed to seal through -penetrations as well as certain membrane penetrations against the spread of fire, smoke and toxic gasses. SpecSeal® Putty expands up to 8 times its original size when exposed to high temperatures or flames. Requiring no tools, SpecSeal® Putty is soft and pliable making it easy to install by hand packing into openings. Its aggressive adhesion makes it suitable for use with all common construction materials as well as cable jacketing and pipes. SpecSeal® Putty remains soft and easy to reuse or retrofit. SpecSeal® Putty Pads provide this same level of protection in a release lined pad for easy application to electrical boxes or other penetrants. The pad is conveniently sized to fit a typical 1-1/2' deep 4S box with no cutting or piecing required. Faced on both sides with a convenient poly liner, SpecSeal® Putty Pads are easily applied with no mess or excessive residue. 2. APPLICATIONS Series SSP Putty and Putty Pads are used to seal through -penetrations as well as construction gaps and blank openings. SpecSeal® Putty Pads are used to seal around electrical boxes to reduce sound transmission (see Technical Update) and increase fire resistance. These pads also provide a metered method of application when sealing through -penetrations and in some applications, are used to provide a cushion to allow movement due to settling, expansion and contraction, or vibration. 3. PHYSICAL PROPERTIES See Table A. 4. PERFORMANCE SpecSeal® Series SSP Putty is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479). Systems have been tested for all common forms of construction and most common penetrants with ratings up to 3 hours. Sound attenuation properties have also been tested as per ASTM C919 and E90. Additionally, SpecSeal® Putty Pads have been tested to UL263 (ASTM E119, NFPA 251) and are classified for up to 2 hours as a Wall Opening Protective Material for 5. SPECIFICATIONS The firestopping putty shall be a one- part, two -stage intumescent, non -hardening compound. The putty, when exposed to high heat or flame shall be capable of expanding a minimum of 5 times. Range of continuing expansion shall be from 230°F to >1,000°F. The putty shall be soft and pliable with aggressive adhesion and shall not contain any water-soluble intumescent ingredients. The putty shall be UL Classified and/or FM Systems Approved and tested to the requirements of ASTM E814 (UL1479). SPECIFIED DIVISIONS DIV. 7 DIV. 13 DIV. 15 DIV. 16 07840 Through -Penetration Firestopping 13900 Special Construction Fire Suppression & Supervisory Systems 15250 Mechanical Insulation —Fire Protection 16050 Basic Electrical Materials & Methods Call STI's automated faxing system for the latest Product and System Information toll -free at 888-526-6800! Specified Technologies, Inc. STI Product Data Sheet • Series SSP Firestop Putty & Putty Pads • FOD-5010 03/2003 www.stifirestop.com • Toll Free 800-992-1180 1 Table A: PHYSICAL PROPERTIES Product Name Series SSP Putty Color Red Odor None Density 1.45 Solids 100% Expansion Begins 230°F Volume Expansion > 500% (free expansion) In -Service Temp. 130°F STC Rating 51 VOC Content** 0.00 Ibs/gal (0.0g/1) ASTM D 3960 and EPA Federal Reference Method 24. use with both metallic and nonmetallic outlet or switch boxes installed in gypsum wallboard assemblies (steel and wood stud assemblies). Boxes protected with SpecSeal® Putty Pads have been successfully tested with box spacing reduced to less than 16". (Not tested nor approved for boxes installed directly back to back). 5. SPECIFICATIONS See Page 1 6. INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation , storage, and in- service temperatures must be below 130°F. No drying or curing is required. SYSTEM SELECTION: Please consult the STI Product and Application Guide as well as the UL® Fire Resistance Directory for applicable through - penetration firestop systems. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool batts (1-1/2" nom. thickness, 4 lb./cu. ft. density) are recommended. Some gypsum wallboard systems utilize fiberglass. Cut forming material oversize to allow for tight packing. Recess forming material at a depth which allows for the proper depth of fill material. Fig. 1: METALLIC PIPE PENETRATIONS - CONCRETE/MASONRY FLOOR Concrete Floor Putty Metallic Pipe UL System No. C-AJ-1090 F Rating: 2 hr • T Rating: 0 hr Steel or Iron Pipe: 6", EMT 4" Annulus: Nominal 11/16" Putty Depth: 1" Forming Material: Optional Mortar Putty i I. Concrete Floor Metallic Pipe UL System No. C-AJ-8055 F Rating: 2 hr • T Rating: 0 hr Steel or Iron Pipe: 6", EMT 4" Annulus: 1"to 61/2" SpecSeal Mortar Depth: 3 1/2' SpecSeal Putty Pad: 1 Layer Encircling Fig. 2: METALLIC PIPE PENETRATIONS - WALLS Steel Sleeve Putty Electrical Concrete ,. ." Cables Wall UL System No. W-J-3090 F Rating — 2 Hr • T Rating —3/4 Hr Electrical, Telephone or Data Cables Annulus: Min 0' Putty Depth: 1" of Putty on both sides. Putty Electrical Concrete r Cables Wall UL System No. W-J-3046 F Rating —2 Hr • T Rating —0 Hr Electrical, Telephone or Data Cables Annulus:1/4" to 3/4" Putty Depth: 5/8" of Putty on both sides Fig. 3: CABLE PENETRATIONS - CONCRETE/MASONRY FLOORS & WALLS Steel Sleeve Concrete Floor Putty Mineral 1 � Wool 11111" I UI Electrical Cables Mineral Wool Putty Concrete Wall Electrical Cables Steel Sleeve UL System No. C-AJ-3154 F Rating —1, 2, 3 & 4 Hr • T Rating —0, 1/2 & 2 3/4 Hr Optional Sleeve - PVC or Steel • Electrical, Telephone or Data Cables • Annulus: 0" to 2" Forming Material: Nom 4 pcf mineral wool • Putty Depth: 1/2" of Putty; 1" for Hr 2 www.stifirestop.com • Toll Free 800-992-1180 STI. Specified Technologies, Inc. FILL MATERIAL: SpecSeal® Putty may be installed by hand packing intothe penetration. Care should be exercised to work the putty into and against all contact surfaces. Install putty to required depth. Work putty into all areas, exercising care to eliminate voids or seams. Where possible, space all penetrants adequately to allow putty to be packed into all voids and assure a good smoke seal. Most firestop system designs utilize a 1" depth of SpecSeal® Putty. PUTTY PADS: SpecSeal® Putty Pads are available as a 7.25" x 7.25" x 3/16" poly release faced pad for protection of recessed electrical boxes and as a through - penetration sealant. The pad is sized to fit a common 1-1/2" deep 4S electrical box. To install remove release liner from one side of pad. Align edge of pad to top of box and center pad. Adhere pad to top of box and bring pad down over the back of the box. Adhering pad to all outer surfaces will create excess material at the corners. Pinch pleat material together and fold against sides of box or trim off as desired. Putty pad must be applied to a uniform depth of 3/16" (one layer of pad) over the exterior surface of box for both 1 and 2 hour applications. Optionally, additional putty may be packed into conduit fittings to prevent the transmission of smoke through the conduit system. Pads may also be used in through - penetrations. Strips of pad may be cut off and packed around penetrants. Pad strips may also be applied to penetrants in a mortar system to create a firestop as well as a cushion to absorb movement due to expansion and contraction or vibration. Fig. 4: CABLE PENETRATIONS - GYPSUM BOARD WALLS Gypsum Wallboard Assembly Putty Electrical Cables UL System No. W-L-3135 FRating —1 &2Hr•TRating —0Hr Electrical, Telephone or Data Cables Annulus: 1/4" to 3/4" Putty Depth: 5/8" of Putty on both sides. Gypsum Wallboard Assembly Putty Electrical Cable UL System No. W-L-3024 F Rating —1 & 2 Hr • T Rating —0,1/2,1 & 2 Hr Electrical, Telephone or Data Cables Annulus: 0" to 1/4" Putty Depth: 5/8" of Putty on both sides. Fig. 5: EXAMPLE OF MAINTAINING STC VALUES OF WALL AND CREATING AN EFFECTIVE SOUND BARRIER 0 U 0 Arrows show path of sound travel. Putty pad reduces sound transmission by blocking path of sound travel. NSTALLATION OF PUTTY PADS ON ELECTRICAL BOXES (Protective Wa11 Opening Material STEP 1 STEP 2 STEP 3 STEP 4 Remove poly liner from one side of pad (Step 1). Align pad to the side of box partially overlapping the stud and adhere. Working to the opposite side of the box to the edges (Step 2). If wall membrane is in place, pack putty into gaps between box and gypsum board slightly overlapping inner wallboard surface. If membrane is to be installed after pad installation, overlap front edge of box so that putty will be compressed around edges of box as wallboard is installed. Cut slits in pad to fit around conduits or cables (Step 3). Press pad to surface of top, bottom, and sides of box (Step 4). Trim excess at comers and apply to conduit fittings connected to the box. Remove exposed poly liner. Optionally, putty may be packed into inside of conduit fittings to prevent passage of smoke. Specified Technologies, Inc. www.stifirestop.com • Toll Free 800-992-1180 3 CLEAN UP: Remove excess material from all contact surfaces immediately. Clean hands or skin using a waterless hand cleaner. When using water -emulsifiable soaps, apply soap and work over areas of skin contact prior to applying water. 7. MAINTENANCE INSPECTION Installations should be inspected periodically for subsequent damage. Any damage should be repaired using SpecSeal® products per the original approved design. Retrofit: When adding or removing penetrants, care should be taken to tightly reseal the penetration. Reseal using SpecSeal® Putty per the approved design. 8. TECHNICAL SERVICE Specified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available at the Technical Library at www.stifirestop.com or through STI's automated attendant fax back system at 888-526-6800. 9. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional informa- tion on the safe handling and disposal of this material. Wash areas of skin contact with soap and water. Avoid contact with eyes. DO NOT APPLY TO EXPOSED ELECTRI- CAL CONDUCTORS. 10. AVAILABILITY SpecSeal® Series SSP Putty is available from authorized STI distributors nationwide. Consult factory for the names and locations of the nearest sales representatives or distributors. n�lllii TABLE C: ORDERING INFORMATION CAT. NO. DESCRIPTION CASE QUAN. SSP100 SSP4S SSP9S 36 in3 (0.6 liter) bar 7.25" x 7.25" x 3/16" pad 9.00"x 9.00" x 3/16" pad 6 20 20 Additional SpecSeal Products... Series SSS Sealant The industry's most versatile sealant provides the firestopping solu- tions for a wide range of combustible and noncombustible applica- tions. Water -based intumescent sealant expands up to 8X! Series LCI Sealant A versatile and economical intumescent product for firestopping a wide array of applications in small commercial or grouped residential construction. SSB Firestop Pillows Durable, monolithic pillows for installations requiring quick and easy retrofitting. Systems designed for pipes, cables and cable tray in all types of construction! Intumescent Wrap Strips Two grades of intumescent wrap strips provide an unmatched combination of flexibility, economy, and expansion (up to 30X). Systems for plastic pipes includ- ing FR Polypropylene up to 8" trade size! Pensil® Silicones Sealants and foam for through -penetrations and construction joints. Unexcelled aging characteristics and flexibility. Firestop Mortar Lightweight, versatile and economical! The best choice for large or complex installations. Molded Firestop Collars Easy to install, economical protection for ABS and PVC pipes (both solid and foam core) as well as CPVC, PVDF, and FRPP. Collars available up to 6" trade size. Elastomeric Joint Seals New economical products for sealing construction joints. Choose caulk or spray applied products tested to UL2079. CITY OF NEW YORK MEA 130-96M Important Notice: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed. WARRANTY: Specified Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase price. Limitations and Exclusions: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USERASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA - COPYRIGHT © 2003 SPECIFIED TECHNOLOGIES, INC. Specified Technologies STIInc. 200 Evans Way • Somerville, NJ 08876 Phone: (800) 992-1180 • Fax: (908) 526-9623 Facts -On -Demand: (888) 526-6800 STI on the WEB: www.stifirestop.com 4 www.stifirestop.com • Toll Free 800.992-1 180 STI. Specified Technologies, Inc. PRODUCT DATA SHEET specsea/,tlli!I1I14 SERIES LCI INTUMESCENT SEALANT APPLICATIONS SpecSeal® LCI Sealant has a broad application base designed to seal a wide variety of common penetrations in light commercial and grouped residential construction. Penetrant types include insulated and non -insulated metallic pipes and tubes, non-metallic pipes and tubes, and common electrical service and power distribution, telephone, data, and TV cabling. This product is also used in conjunction with other SpecSeal® Products such as SpecSeal® Firestop Collars and Wrap Strips to protect larger plastic pipes. See Table A for a summary application list. PHYSICAL PROPERTIES Properties Color Odor Density pH In Service Temperature Flame Spread Smoke Developed STC Rating (ASTM E90/ASTM C919) VOC Content (EPA Method 24/ASTM D3960) Shelf Life Volume Expansion Storage Temp. ' Tested to ASTM E84(tH.723)atN%surracecaerage(modiiedtestra sealantsandcar@s) eries LCI; Red Mild Latex 9.0 lb/gal (1.08 kg&.) 9.0 s 130°F (54°C) 0* 5' 62 Q29bsgal (35.0gt.) 2 yrs 10X Free Expansion 130°F (54°C) PRODUCT DESCRIPTION SpecSeal® LCI Sealant is a versatile and economical intumescent product intended for firestopping a wide array of applications in small commercial or grouped residential construction and other structures with similar applications. SpecSeal® LCI Sealant is available in a single grade that has excellent caulk- ing properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal® LCI Sealant does not contain PCB's or asbestos. SpecSeal® LCI Sealant is storage stable (when stored according to the manufacturer's recommenda- tions), and will not separate or shrink when dried, SpecSeal® Series LCI Sealant will adhere to all com- mon construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable jackets. FEATURES • Economical: High performance without the high price! • Highly Intumescent: Expands up to 8 times. • Excellent Smoke Seal • Water Resistant : Will not re -emulsify when dry. • Water -Based for easy installation, cleanup, and disposal. • Acoustically Tested: Reduces noise transmission • Safe...Low VOC's, No Solvents, Non -Halogenated • Palntable PERFORMANCE SpecSeal® LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) and ASTM E1966 (UL2079) as well as to the time -temperature requirements of ASTM E 119 (UL263). LCI provides up to a 2-hour fire rating for typical service penetrations through concrete or wood floors, concrete or masonry walls, as well as gypsum board walls (3-hour for metallic pipe, conduit and tubing). SpecSeal® LCI Sealant meets Class A finish requirements for Flame Spread and Smoke Development when tested in accordance with ASTM E84 (UL723). SpecSeal® LCI Sealant is also acoustically tested, demonstrating excellent sound attenuation properties. SYSTEM COMPATIBLE US 3173 FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS AND THROUGH -PENETRATION FIRESTOP SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY. FM APPROVED SPECIFICATIONS The firestopping sealant shall be awater-resistant, intumescent latex sealant. The sealant when exposed to high heat or flame shall exhibit a free expansion of up to 8 times its original volume. The firestopping sealant shall contain no water soluble nor hygroscopic ingredients and shall be acoustically tested. The sealant shall be UL Classified and/or FM approved and tested to the requirements of ASTM E814 (UL1479) and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 07840 DIV. 13 13900 DIV. 15 15250 DIV. 16 16050 Through -Penetration Firestopping Special Construction Fire Suppression & Supervisory Systems Mechanical Insulation — Fire Protection Basic Electrical Materials & Methods =V— .�= Technical Service 1-800-992-1180 STI• www.stiflrestop.com STI Product Data Sheet • Series LCI Intumescent Sealant • FOD-5062 06/2007 1 Fig 1: METALLIC PIPES- Concrete/Masonry Floors & Walls Fig 2: INSULATED METALLIC PIPES - Concrete/Masonry Floors & Walls LCI Sealant Steel Sleeve Mineral Wool Metallic Pipe Metallic Concrete Pipe Floor UL System No. C-AJ-1353 F Rating: 3 Ft • T Rating: 0 Ft Steel a Iron Pipe: <12", Copp& Pipe: <4" Antos: 0" to 2" Sealant Depth 1/4" Faring Material: Nom 4 pd mineral wud (2 1/4" Depth) LCI Sealant Concrete Walt UL System No. W-J-1098 F Rating:2 Hr•T Rating 1/4, 3/4 & 1 Hr Steel or Iron Pipe: <8", Capper Pipe: <4" Annulus 0" to 2" Sealant Depth: 518" LCI Sealant Steel Sleeve Mineral Wool Mineral Wool Concrete Floor Insulated Concrete Wal Pipe Assembly UL System No. C-AJ-5138 F Rating: 2 Hr • T Rating: 3/4 a 1 Hr Steel or Iron Pipe: 6", Copper ape: 4" Pipe Covering: M. 2' tber glass a mineral wool pipe instlaliat. Anntlus:1/4" to 1-5/8" • Sealant 1/2' Fairing: Nom. 4 pd mineral wool (3' depth) Steel Sleeve LCI Sealant (Both Sides) Insulated Metallic Pipe SEALANT REQUIREMENTS IN CUBIC INCHES PER 1/4 INCH OF INSTALLED DEPTH* Pipe Size Diameter of Opening (in.) 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10 12 14 26 Trade Pipe Size 0.D. 0.5" 0.840 0.3 0.6 1.6 3.0 4.8 6.9 9.6 12.4 19.5 28.1 38.3 132.6 1" 1.315 0.1 0.4 1.5" 1.900 2" 2.375 1.4 1.1 0.7 2.8 2.4 2.0 4.6 4.2 3.8 6.7 6.4 6.0 9.3 8.9 8.5 12.2 11.9 11.5 19.3 18.9 18.5 27.9 27.6 27.2 38.1 132.4 37.8 132.0 37.4 131.6 2.5" 2.875 3" 3,500 0.1 1.5 3.3 0.7 2.5 5.4 8.0 10.9 18.0 4.7 7.2 10.2 17.2 26.7 36.9 131.1 25.9 36.1 130.3 3.5" 4.000 1.8 3.9 6.5 9.4 16.5 25.1 35.3 129.6 4" 4.500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128.7 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 8" 10" 12" 24" 8.625 10.750 12.750 24.000 4.9 13.6 5.6 23.8 15.8 6.6 118.0 110.0 100.8 19.6 IMPORTANT NOTE: This table is for estimation purposes only. Consult UL Fire Resistance Directory or STI Product & Application Guide for specific installation requirements and limitations Metric Estimation Table available upon request. 'Difeot Sea'ant Depth? t2 Mutipyby2 58" Mutipyby2.5 r Mutipyby4 1-14" Mutidy by Fig. 3: ELECTRICAL, DATA OR COMMUNICATIONS- Gypsum Walls Cable Bundle Gypsum Wallboard Assembly LCI Sealant (Both Sides) UL System No. W-L-3169 F Rating: 1, 2 Hr• T Rating: to and 3/4 Up to 4-1/2"cable bundle Annulus: 0"to % "• Sealant: 5/8" Non -Metallic Conduit Gypsum Wallboard Assembly LCI Sealant (Both Sides) UL System No. W-L-2241 F Rating: 1, 2 Hr • T Rating: 0, Y4,1,1-3/4 <2"Rigid PVC orENMT, CPVC, ABS Annulus: 0-1 "• Sealant 5/8" TABLE A: APPLICATIONS TESTED AND CLASSIFIED FOR FIRE RESISTANCE • Metallic Pipes induding steel, iron, or copper pipe and tubing. • Nonmetalllc Pipes, Conduits & Tubing including PVC, CPVC, ABS, and PEX. • Electrical & Electronic Cabling including service entrance, power distribution, computer, telephone, and television. • Metal Ductwork including HVAC, bath and dryer vents. • Insulated Pipes including heating, cooling, and condensation applications. • Complete Wood Floor flrestopping package for electrical, plumbing, HVAC, telephone, and television. 2 STI Product Data Sheet • Series LCI Intumescent Sealant • FOD-5062 06/2007 Technical Servlce 1-800-992-1180 = www.stiflrestop.com S r'I. INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35°F (2°C) and 100°F (38°C). Allow product to dry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed information pertaining to individual application systems. Please consult the Product & Application Guide as well as the UL® Fire Resistance Directory for additional information. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool batts with a minimum nominal density of 4 PCF (64 kg/m3) are generally required. Cut forming material oversize to allow for tight packing. Position forming material to allow for the proper depth of fill material. FILL MATERIAL: SpecSeal® LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason's trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be painted using most non -solvent based paints. FIg. 4: BARE & INSULATED METALLIC PIPES- Wood Floor Assemblies Metallic Pipe Wood Floor Assembly LCI Sealant LCI Sealant LCI Sealant UL System No. F-C-1074 F Rating: 1 & 2 Hr • T Rating:''/a, / and 1 Hr Steel, Iron or Copper: 4"• Chase wall optional. Annulus: 0"to 1 "• Sealant: 5/8" bottom, 3/"top LCI Sealant Insulated Metallic Pipe Wood Floor Assembly UL System No. F-C-5043 F Rating: 1 & 2 Hr • T Rating: 3/4 and 1 Hr Steel, Iron or Copper: 4" Pipe covering: l"Fiber Glass, Mineral fiber or AB/PVC • Chase wall optional. Annulus: 0-to 1"• Sealant: 5/8"bottom, 3/4"top. In gypsum wallboard penetrations, apply a minimum cove bead of 1/4" (6 mm) at the interface of the penetrant with both exterior wall surfaces, SMOKE SEALING: In some applications including firestop collars, SpecSeal® LCI Sealant is recommended as a smoke seal. It is sugge„ad in these applications that the sealant be applied to both sides of walls. In floor applications, a sealing bead is suggested top and bottom, LIMITATIONS: SpecSeal® LCI Sealant is water - based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non -porous or impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that pre- vents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. FIg. 5: BARE & INSULATED METALLIC PIPES- Gypsum Walls Metallic Pipe LCI Sealant (Both Sides) Gypsum Wallboard Assembly UL System No. W-L-1222 F Rating:1, 2 Hr• T Rating: IA, 3/a, 1 Hr Steel or Iron pipe: 8", Copper pipe: 4" Annulus: 0"to 2"c Sealant: 5/8" Insulated Metallic Pipe Gypsum Wallboard Assembly LCI Sealant (Both Sides) UL System Nos. W-L-5121, W-L-5122 F Rating: 1, 2 Hr • T Rating: 1 Hr & 1/4 Hr Steel or Iron pipe: 6", Copper pipe: 4" Pipe covering: Max. 2"fiber glass, 3/"AB/PVC or 2"mineral fiber Annulus: 0"to 1-1/2". Sealant: 5/8" LCI Sealant (Both Sides) Gypsum AC Line Wallboard it-11 Set Assembly UL System No. W-L-8025 F Rating: 1, 2 Hr • T Rating: i/ Hr AC Line Set: Two copper tubes, one with 3/a"AB/PVC and thermostat wire Annulus: 0" to 1 "• Sealant 5/8" Technical Service 1-800-992-1180 STI www.stifirestop.com STI Product Data Sheet • Series LCI Intumescent Sealant • FOD•5062 06/2007 3 _ _ = Specified _—= Technologies STI Inc. GENERAL CERTIFICATE of CONFORMANCE Description: SpecSeal® Firestop Products Included Products: Series SSSlntumescent Sealant Series LCllntumescent Sealant Series LC Latex Endothermic Sealant Series SSP Intumescent Putty Series EP Power ShieldTM Box Insert Series SSWRED Intumescent Wrap Strips Series SSWBLUIntumescent Wrap Strips Series SSC Intumescent Firestop Collars Series LCC Intumescent Firestop Collars 200 Evans Way, Suite 2 Somerville, N .J. 08876 Phone: (908) 526-8000 Fax: (908) 526-9623 Toll Free: (800) 992-1180 Series SSB Intumescent Firestop Pillows Series AS100 Elastomeric Spray Series AS200 Elastomeric Spray Series ES100 Elastomeric Sealant Series SSM Firestop Mortar Pensil Series PEN200 Silicone Foam Pensil Series PEN300 Silicone Sealant Pensil Series PEN300SL Silicone Sealant These products are tested to the following standards where applicable: ASTM STANDARD: E 814 Fire Tests of Through -Penetration Fire Stops E 119 Fire Tests of Building Construction and Materials E 1966 Fire -Resistive Joint Systems E 84 Surface Burning Characteristics of Building Materials E 1399 Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems UL STANDARD 1479 Fire Tests of Through -Penetration Firestops 263 Fire Tests of Building Construction and Materials 2079 Tests for Fire -Resistance of Building Joint Systems 723 Tests for Surface Burning Characteristics of Building Materials Chemical Content Statements: No asbestos, PCB's or water-soluble intumescent ingredients are used or contained in these products. James P. Stahl, Jr. Technical Manager February 1, 2002 Date „...-_, ,:-..........._= STL Material Safety Data Sheet 01-JAN-2006 SpecSeal® TYPE LCI SEALANT CHEMICAL PRODUCT/COMPANY IDENTIFICATION Material Identification PRODUCT NAME SpecSeal® LCI Sealant CHEMICAL FAMILY Mixture Company Identification MANUFACTURER/DISTRIBUTOR Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 PHONE NUMBERS Product Information : 1-908-526-8000 Emergency :1-800-255-3924 COMPOSITION/INFORMATION ON INGREDIENTS INGREDIENT NAME CAS NUMBER Proprietary mixture HAZARDS IDENTIFICATION ************EMERGENCY OVERVIEW*************** * Possible skin and eye irritant. Pale, red paste. * *********************************************************** Potential Health Effects: EYE: Contact may cause irritation. SKIN: Contact may cause irritation. INGESTION: Relatively non -toxic. INHALATION: Irritation of the nose, throat, and lungs may result from over -exposure to vapors or mist. CHRONIC (CANCER) INFORMATION: Not classified as carcinogenic. LONG TERM TOXIC EFFECTS: None known. Page 1 of 3 MSDS-SpecSeal®TYPE LCI Sealant FOD-5063 FIRST AID MEASURES First Aid INHALATION: Remove to fresh air. SKIN CONTACT: Wash thoroughly. EYE CONTACT: Irrigate eyes with running water for at least 15 minutes. Get medical attention if irritation develops. INGESTION: None applicable. FIRE FIGHTING MEASURES Not a fire hazard. EXTINGUISHING MEDIA Dry Chemical; Carbon Dioxide; Foam; Water spray for large fires. SPECIAL FIRE FIGHTING PROCEDURES' As for surrounding fire. ACCIDENTAL RELEASE MEASURES Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE EQUIPMENT during clean-up. HANDLING AND STORAGE Store under ambient conditions. No special handling required. EXPOSURE CONTROLS/PERSONAL PROTECTION EYE PROTECTION REQUIREMENTS' Safety glasses/goggles. SKIN PROTECTION REQUIREMENTS: Gloves. RESPIRATOR REQUIREMENTS: None, VENTILATION REQUIREMENTS• If needed, use local exhaust ventilation to keep airborne concentrations below the TLV. Exposure Guidelines Exposure Limits PEL(OSHA) : Particulates (Not Otherwise Classified) 15 mg/m3, 8 Hr. TWA, total dust 5 mg/m3, 8 Hr. TWA, respirable dust TLV(ACGIH): None Established PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL FORM Pale, red paste with minimal odor SPECIFIC GRAVITY 1.10 PERCENT VOLATILES 22 EVAPORATION RATE >1 BOILING POINT 100 deg. C SOLUBILITY IN WATER Infinitely dilutable STABILITY AND REACTIVITY STABILITY: This is a stable material. CONDITIONS TO AVOID Storage >55 deg. C HAZARDOUS POLYMERIZATION' Will not occur. INCOMPATIBILITIES:.............................. None special. TOXICOLOGICAL INFORMATION Mixture not tested but based on components: May be irritating to skin and eyes and may aggravate existing skin and eye conditions. None of the components are listed as carcinogens. Page 2of3 MSDS - SpecSeal® TYPE LCI Sealant FOD-5063 ECOLOGICAL INFORMATION No data. DISPOSAL CONSIDERATIONS Waste Disposal: Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations. TRANSPORTATION INFORMATION DOT — not regulated. REGULATORY INFORMATION U.S. Federal Regulations TSCA Inventory Status: Reported/Included. Section 313 Supplier Notifications. This product contains no toxic chemicals subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right -To -Know Act of 1986 and of 40 CFR 372: OTHER INFORMATION NPCA-HMIS Rating Health :1 Flammability : 0 Reactivity :0 Personal Protection rating to be supplied by user depending on use conditions. STATE RIGHT -TO -KNOW LAWS No substances on the state hazardous substances list, for the states indicated below, are used in the manufacture of products on this Material Safety Data Sheet, with the exceptions indicated. While we do not specifically analyze these products, or the raw materials used in their manufacture, for substances on various state hazardous substances lists, to the best of our knowledge the products on this Material Safety Data Sheet contain no such substances except for those specifically listed below: SUBSTANCES ON THE NEW JERSEY WORKPLACE HAZARDOUS SUBSTANCE LIST PRESENT AT A CONCENTRATION OF 1% OR MORE (0.1% FOR SUBSTANCES IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): NJTSRN- LC1300 WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIATO CAUSE CANCER: Possible traces of formaldehyde, ethyl acrylate, acetaldehyde, acrylamide and acrylonitrile. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIATO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM: None known. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the data compiled. However, no representation, warranty, or guarantee is made as to its accuracy, reliability or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur form the use of this information. Responsibility for MSDS : Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 Page 3 of 3 MSDS - SpecSealg) TYPE LCI Sealant FOD-5063 System No. W-J-3090 F Rating - 2 hr T Rating - 3/4 hr Section A -A 1. Wall Assembly - Min 5 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall assembly may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 4-1/2 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Steel Sleeve - Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT), steel conduit or Schedule 5 (or heavier) steel pipe sleeve cast or grouted into wall assembly. Sleeve may be installed flush with or extend up to 18 in. beyond one or both wall surfaces. 3. Cables - Aggregate cross -sectional area of cables in steel sleeve to be max 48 percent of the aggregate cross -sectional area of the sleeve. Cables to be rigidly supported on both sides of wall assembly. Any combination of the following types and sizes of copper conductor cable may be used: A. Max 200 pair No. AWG (or smaller) copper conductor cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 3/C No. 2/0 AWG (or smaller) aluminum or copper conductor service entrance cable with PVC insulation and jacket. C. Max 3/C No. 8 AWG (or smaller) nonmetallic sheathed (Romex) cable with copper conductors, PVC insulation and jacket. D. Max 7/C No. 2/0 AWG (or smaller) multiconductor power and control cables with XLPE or PVC insulation and XLPE or PVC jacket. E. Max RG/U (or smaller) coaxial cable with fluorinated ethylene insulation and jacketing. F. Max 62.5/48 fiber optic cable with PVC insulation and jacketing. G. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with PVC insulation and jacket. H. Max 4/C No. 2/0 aluminum or copper conductor aluminum or steel Metal -Clad# or Armored -Clad# cable. 4. Firestop System - The firestop system shall consist of the following: A. Packing Material - When required (See table in Item 3B), min 1 in. thickness of min 4 pcf density mineral wool batt insulation firmly packed into each end of sleeve as a permanent form. Packing material to be recessed from each end of sleeve as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* - Sealant or Putty - Fill material applied to appropriate thickness within steel sleeve, flush with edges of steel sleeve on both surfaces of wall. See table below for fill material thickness requirements. Fill Material Type Thickness, In. Packing Material Require SpecSeal 100 Series Sealant 1/2 in. Yes SpecSeal 100 Series Sealant 1 in. No SpecSeal LCI Sealant 1 in. Yes SpecSeal Putty 1 in. No SPECIFIED TECHNOLOGIES INC - SpecSeal Series 100, 101, 102, 120, 129 or 105 Sealant, SpecSeal LCI Sealant or SpecSeal Putty *Bearing the UL Classification Mark #Bearing the UL Listing Mark Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: August 13, 2002 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv©stifirestop.com • Website:www.stifirestop.com STI W-J-3090 PAGE 1 OF 1 System No. W-L-3024 F Ratings - 1 and 2 Hr (See Items 2 and 2A) T Ratings - 0, 1/2, 1 and 2 Hr (See Items 2 and 2A) L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A © © ICI I-"- A Section A -A u u u 1. Wall Assembly - The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* - 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 2-1/2 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Cables - One cable to be installed either concentrically or eccentricity within the firestop system. The annular space within the firestop system shall be a min 0 in. (point contact) to a max 1/4 in. Cable to be rigidly supported on both sides of wall assembly. The following types and sizes of cables may be used: A. Max 200 pair No. 24 AWG (or smaller) copper conductor cable with polyvinyl chloride (PVC) jacketing and insulation. When 200 pair No. 24 AWG telephone cable is used, T Rating is 0 hr. When 50 pair No. 24 AWG telephone cable is used, T Rating is equal to the F rating of the firestop system. B. Max 3/C No. 2/0 AWG (or smaller) aluminum conductor service entrance cable with PVC insulation and jacketing. When service entrance cable is used, the T Rating is equal to the F Rating of the firestop system. C. Max 1/C-750 kcmil copper conductor power cable with cross -linked polyethylene (XLPE) insulation and jacketing. When 1/C-750 kcmil cable is used, the T Rating is equal to the F Rating of the firestop system. D. Max 3/C No. 8 AWG (or smaller) PVC insulated and jacketed nonmetallic sheathed (Romex) cable. When Romex is used, the T Rating is equal to the F Rating of the firestop system. E. Max RG59/U (or smaller) coaxial cable with fluorinated ethylene insulation and jacketing. When coaxial cable is used, the T Rating is equal to the F Rating of the firestop system. F. Max 62.5/125 micron fiber optic cable with PVC insulation and jacketing. When fiber optic cable is used, the T Rating is equal to the F Rating of the firestop system. G. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with Hylar insulation and jacketing. When data cable is used, the T Rating is equal to the F Rating of the firestop system. 2A. Through -Penetrating Product* - As an alternate to Item 2, max one through -penetrating product to be installed either concentrically or eccentrically within the firestop system. Through -penetrating product to be rigidly supported on both sides of wall assembly. The following types of through -penetrating products may be used: A. Max four copper conductors No. 4/0 AWG (or smaller) aluminum or steel Armored Cable+ or Metal -Clad Cable+. When armored or metal -clad cable is used, the T Rating is 1/2 hr. AFC CABLE SYSTEMS INC B. Two or more twisted copper conductors No. 6 AWG (or smaller) Power Limited Circuit Cable+ with or without a jacket under a metal armor. When Power Limited Circuit Cable+ is used, the T Rating is 1/2 hr. AFC CABLE SYSTEMS INC C. Two or more twisted copper conductors No. 10 AWG (or smaller) Power Limited Fire Alarm Cable+ with or without a jacket under a metal armor. When Power Limited Fire Alarm Cable+ is used, the T Rating is equal to the F Rating of the firestop system. AFC CABLE SYSTEMS INC D. Two or more twisted copper conductors No. 12 AWG (or smaller) Non Power Limited Fire Alarm Cable+ with or without a jacket under a metal armor. When Non Power Limited Fire Alarm Cable+ is the T Rating is equal to the F Rating of the firestop system. AFC CABLE SYSTEMS INC 3. Fill Void or Cavity Material* - Sealant or Putty - Min 5/8 in. thickness of fill material installed within annulus, flush with both surfaces of wall assembly. Additional fill material installed such that a min 1/4 in. diam crown is formed around the through -penetrant on both sides of the wall. SPECIFIED TECHNOLOGIES INC - SpecSeal Series 100 Sealant or SpecSeal Putty *Bearing the UL Classification Marking +Bearing the UL Listing Mark Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: August 6, 2003 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv©stifirestop.com • Website:www.stifirestop.com STI W-L-3024 PAGE 1 OF 1 System No. F-C-2032 F Rating - 1 Hr T Ratings - 1/4 and 1 Hr (See Item 2) Section A -A II 1. Floor - Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The general construction details of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 4 in. B. Wood Joists - Nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in. lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. C. Furring Channels (Not Shown) - Resilient galv steel furring installed perpendicular to wood joists (Item 1 B) between gypsum board (Item 1 D) and wood joists as required in the individual Floor -Ceiling Design. D. Gypsum Board* - Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor -Ceiling Design. Gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 4 in. 2. Chase Wall (Not Shown) - When required (See table under Item 2), the through penetrant (Item 2) shall be routed through a 1 hr fire -rated single, double or staggered wood stud/gypsum board chase wall. Depth of chase wall stud cavity to be min 1/2 in. greater than diam of opening cut in sole and top plates to accommodate the through penetrant (Item 2). The chase wall shall be constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Nom 2 by 4 in., 2 by 6 in. or double 2 by 4 in. lumber studs. B. Sole Plate - Nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. C. Top Plate - The double top plate shall consist of two nom 2 by 4 in. or 2 by 6 in. or two sets of parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 4 in. D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: October 14, 2002 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techservastifirestop.com • Website:www.stifirestop.com STI F-C-2032 PAGE 1OF2 The specified 3. Through openings than floor A. B. C. D. E. F. G. H. The penetrant use ofthe chase wall is dependent upon the type ofthrough penetrant used mm |nItem 2. -Penetrants ' One nonmetallic pipe, conduit or tubing to be installed within the firw6topaystnm. [)iann of hole -sawed through flooring system and through gypsum wallboard ceiling tobe1/4in. to1'5/8in. larger the outside diam of through -penetrant. Pipe, conduit or tubing to be rigidly supported on both sides of the -ceiling assembly. The following types and sizes of nonmetallic pipes, conduits or tubing may be used: Polyvinyl Chloride (PVC) Pipe - Nom 2 in. diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in C|DSed (pnoo8SS or supply) or vented (drain, waste or vent) piping systems. Rigid Nonmetallic Conduit(RNC)+ - Nom 2 in. diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347Vfthe National Electrical Code (NFPANo. 7O). Chlorinated Polyvinyl Chloride (CPY/C) Pipe -Num2in. diam(or smaller) G[]R17CPVC pipe for use in C|0S8d (p[OogoG or supply) or vented (drain, vVoate or vent) piping systems. Acry/onitri|e Bmkmdieme Styrene (ABS) Pipe - Nom 1-1/2 in. diam (or smaller) Schedule 48cellular o| solid core ABS pipe for use in closed (process or supply) or vented (drain, vvGGt8 or vent) piping systems. Po|ybutyleme (PB) Pipe - Nom 1 in. diam (or smaller) G[}R 11 PB pipe for use in closed (pn/oeaa or supply) piping systems. Cross Linked Polyethylene Aluminum -Cross Linked Polyethylene (PEXAL-PEX)Tubing - Nom 1 in. diGnn (or smaller) GDR 5 PEX-AL'PEXtubiDg for use in o|0Snd (process O[supply) piping systems, Cnmea Linked Polyethylene (pEX) Tubing - Nom 1 in. diom (or smaller) GOR S PEX tubing for use i|/ o/oaud (process 0[supply) piping GySt80G Electrical Nonmetallic Tubing (ENl)+ - Nom 2 in. dium (or smaller) PVC tubing installed in accordance with Article 331 of the NUtiOD8| B8Ct[iC@| Code (NFPA No. 70). use Ofthe chase wall (Item 1.1)iadependent upon the type and diann0fthrough and type of piping ayotgnn used as tabulated below: Type ofThrough Max QiemnofThrough Type mfPiping Use of Penetrant Penetrant In. System Chase Wall PVC pipe (a) 2 O|oa8d or Vented Optional RNC 2 Not Applicable Optional {|PVC pipe (8) 2 Closed or Vented Optional ABS pipe 1-1/2 Closed orVented Optional PBpipe 1 {||oGOd [}ptiOD@| PEX-AL-PEXtubin0 1 Closed Required PE}(tubing 1 Closed Optional ' ENT 2 Not Applicable Optional (a)When nom di80 Of pipe exceeds 1 in. and chase wall (Item 1.1) is not used ' T Rating is 1/4 hr. VVhmn2A, 213°2C°2E°2F,2Gmr2Himused, the annular space shall bemin Qin. (point contact) tomax 1~5/8 in. VVhen2D is used, the annular space shall be min 1/8 in. to max 1 in. unless the pipe is ontained within mchase wall, imwhich case the minimum annular space isQin. (point cmm&act). 4. Fill, Void or Cavity Material* - Sealant - Min 3/4 in. thickness of fill material applied within annulus on top surface of floor. Min 5/8 in. thickness of fill material applied within annulus on bottom surface of ceiling or lower top plate of chase wall assembly. Additional fill material to be installed such that a min 1/8 in. crown is formed around the through penetrant on bottom surface of ceiling or lower plate of chase wall assembly. SPECIFIED TECHNOLOGIES INC -8peoGga|1OO'1O1.1O2.1O5.120or129Sealant, SpecSeal'LC1' +B88riDg the UL Listing Mark *Bearing the ULClassification Marking Inc��� �����- �����NN���UU��, @�� ����� ~- � �� SpecifiedTechnologies. �������� ���������� �N0 � courtesy nf UnderwritersLaboratories, |no. � ��� � Reproduced Created orRevised: O�ober14.2OU2 '.� .* 0� ' ' - FC-2032 PAGE xmp» n7���� � 0 ��~�~� �[�89�118o"(S0$5�'m00"��x���u31-8w5^�m�|�oh�w�o�m�p��"0wbsite:www.wifirestop.00m •••• ••• •••••• •••••.• ems System No. W-L-3169 F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 1/4 and 3/4 Hr (See Item 2A) Section A -A u 1. Wall Assembly - The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3-5/8 in. wide and spaced max 24 in. OC. B. Gypsum Board* - Thickness, type, number of layers and fasteners as specified in the individual Wall and Partition Design. Max diam of opening is 5 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Cables - Max 4-1/2 in. diam tight bundle of cables to be installed eccentrically or concentrically within the opening. The annular space between the cables and the periphery of the opening shall be min 0 in. (point contact) to max 1/2 in. Cable bundle to be rigidly supported on both sides of the floor or wall assembly. The following types and sizes of cables may be used: A. Max 200 pair No. 24 AWG (or smaller) copper conductor with polyvinyl chloride (PVC) insulation and jacketing material. B. Max 1 /C No. 350 kcmil (or smaller) copper conductor cable with cross -linked polyethylene (XLPE) jacket. C. Max 7/C No. 12 AWG (or smaller) copper conductor power and control cables with XLPE or PVC insulation with XLPE or PVC jacket. D. Max 3/C No. 2/0 AWG (or smaller) copper or aluminum conductor SER cables with PVC insulation and jacket. E. Max 3/C No. 2/0 AWG (or smaller) copper conductor PVC jacketed aluminum clad or steel clad TEK cable. F. Max 110/125 fiber optic (F.0.) cable with PVC insulation and jacket. G. Max 3/C with ground No. 8 AWG (or smaller) copper conductor NM cable (Romex) with PVC insulation and jacket. H. Max RG/U coaxial cable with fluorinated ethylene insulation and jacket. I. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with Hylar jacket and insulation. 2A. Through Penetrating Product* - As an alternate to the cables (Item 2), max 4 in. diam tight bundle of max 4/C No. 2/0 AWG (or smaller) aluminum or steel Armored Cable+ or Metal Clad Cable+ installed within the opening. Annular space between through -penetrating products and periphery of opening to be min 0 in. (point contact) to max 1 in. Through penetrating product rigidly supported on both sides of floor or wall assembly. When Armored Cable or Metal Clad Cable is used, T Rating is 1/4 hr. AFC CABLE SYSTEMS INC 3. Fill, Void or Cavity Material* - Sealant - Min 5/8 in. thickness of fill material applied within annulus, flush with both surfaces of wall assembly. Sealant to be forced into interstices of cable bundle to max extent possible. At point contact location, min 1/4 in. diam bead of fill material applied at cable bundle/gypsum board interface on both surfaces of wall. SPECIFIED TECHNOLOGIES INC - SpecSeal LCI Sealant *Bearing the UL Classification Marking Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: October 4, 2000 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv©stifirestop.com • Website:www.stifirestop.com STI W-L-3169 PAGE 1 OF 1 i System No. W-L-1223 F Ratings - 1 and 2 Hr T Ratings - 1/4, 3/4 and 1 Hr (See Item 3) Section A -A 1. Wall Assembly - The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3-5/8 in. wide and spaced max 24 in. OC. B. Gypsum Board* - Thickness, type, number of layers and fasteners as specified in the individual Wall and Partition Design. Max diam of opening is 10-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Steel Sleeve - Cylindrical sleeve fabricated from 0.0125 in. thick (30 gauge) galv sheet steel and having.a min 2 in. lap along the longitudinal seam. Length of the sleeve to be equal to or max 2 in. greater than the thickness of the wall. Sleeve installed by coiling the sheet steel to a diam smaller than the through opening, inserting the coil through the opening and releasing the coil to let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with or extend a max 1 in. beyond each surface of the wall. As an alternate, steel sleeve may consist of nom 10 in. diam (or smaller) Schedule 5 (or heavier) steel pipe sleeve friction -fitted into circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with or extend a max 1 in. beyond each surface of the wall. 3. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the steel sleeve shall be min 0 in. (point contact) to max 2 in. Pipe, conduit or tube to be rigidly supported on both sides of the wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: A. Steel Pipe - Nom 8 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. B. Iron Pipe - Nom 8 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 6 in. diam (or smaller) rigid steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. diam (or smaller) flexible steel conduit. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: July 26, 2006 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techservOstifirestop.com • Website:www.stifirestop.com W-L-1223 PAGE 1 OF2 D. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. E. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube. Type of Penetrant Max Diam T Rating Steel or iron pipe, steel 2 in. 1 hr conduit or EMT Steel or iron pipe, steel 8 in. 3/4 hr conduit or EMT Copper pipe or tube 4 in. 1/4 hr 3A.Through Penetrating Product* - Flexible Metal Piping - As an alternate to Item 3, one nom 2 in. diam (or smaller) steel flexible metal pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tube and the steel sleeve shall be min 0 in. (point contact) to max 2 in. Pipe to be rigidly supported on both sides of the wall assembly. When flexible metal piping is used, T Rating is 1 hr. OMEGA FLEX INC GASTITE, DIV OF TITEFLEX WARD MFG INC 4. Firestop System - The firestop system consists of the following items: A. Packing Material - Min 1 in. thickness of min 4 pcf mineral wool batt insulation compressed and tightly packed into each end of steel sleeve. Packing material recessed from each end of steel sleeve. When alternate steel pipe sleeve is used, packing material may be omitted from the firestop system. B. Fill, Void or Cavity Material* - Sealant - Min 5/8 in. thickness of fill material applied within annulus, flush with each end of steel sleeve. At point contact location, min 1/4 in. diam bead of fill material applied at metallic pipe/steel sleeve interface on both surfaces of wall. Optionally, a min 1/4 in. diam bead of fill material shall be applied around the circumference of the steel sleeve at its egress from each side of the wall. SPECIFIED TECHNOLOGIES INC - SpecSeal LCI Sealant *Bearing the UL Classification Mark Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STICreated or Revised: July 26, 2006 11 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com W-L-1223 PAGE 2 OF 2 System No. F-C-8029 F Rating - 1 Hr T Ratings - 1/2 and 3/4 Hr (See Item 2) Ar Section A -A I I I I I I I I I 1. Floor -Ceiling Assembly - The 1 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max area of rectangular opening cut in flooring is 43-1/2 sq in. with a max width dimension of 3 in. and with a max length dimension of 14-1/2 in. Longer dimension of rectangular opening to be perpendicular to wood joist direction. B. Wood Joists - Nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. C. Gypsum Board* - Thickness, type, number of layers and fasteners as required in the individual Floor -Ceiling Design. Max area of rectangular opening cut in gypsum board ceiling is 43-1/2 sq in. with a max width dimension of 3 in. and with a max length dimension of 14-1/2 in. 1A.Chase Wall - (Optional, Not Shown) - The through penetrants (Item 2) may be routed through a 1 hr fire rated single, double or staggered wood stud/gypsum board chase wall. Depth of chase wall stud cavity to be min 1/2 in. greater than width of opening cut in sole and top plates to accommodate the through penetrants. The chase wall shall be constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Nom 2 by 4 in., 2 by 6 in. or double nom 2 by 4 in. lumber studs. B. Sole Plate - Nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Max area of rectangular opening cut in sole plate is 43_1/2 sq in. with a max width dimension of 3 in. and with a max length dimension of 14-1/2 in. C. Top Plate - The double top plate shall consist of two nom 2 by 4 in., two nom 2 by 6 in. or two sets of parallel 2 by 4 in. lumber plates, tightly butted. Max area of rectangular opening cut in top plate is 43_1/2 sq in. with a max width dimension of 3 in. and with a max length dimension of 14-1/2 in. D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as specified in the individual Wall and Partition Design. 2. Through Penetrants - One or more metallic or nonmetallic pipes, conduits, tubing or cables to be installed either concentrically or eccentrically within the opening. Min separation between penetrants to be 1 in. Annular space between the penetrants and the periphery of the opening shall be min 0 in. (point contact) to max 1 in. Penetrants to be rigidly supported on both sides of floor -ceiling assembly. The following types and sizes of through penetrants may be used: A. Metallic Penetrants - The following types and sizes of metallic pipes, conduits or tubes may be used: Al .Steel Pipe - Nom 2 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. A2.Iron Pipe - Nom 2 in. diam (or smaller) cast or ductile iron pipe. A3.Copper Pipe or Tubing - Nom 2 in. diam (or smaller) Type L (or heavier) copper tube or Regular (or heavier) copper pipe. A4.Conduit - Nom 2 in. diam (or smaller) rigid steel conduit, electrical metallic tubing (EMT) or flexible steel or aluminum conduit. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: October 11, 2002 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-8029 PAGE 1 OF2 B. Nonmetallic Penetrants - The following types and sizes of nonmetallic pipes, conduits or tubes may be used: B1.Po|yNny| Chloride (PVC) Pipe - Nom 2 in. diam (or smaller) Schedule 40oo|id nrcellular core PVC pipe for use in closed (process orsupply) orvented (dnain.waste orvent) piping systems. B2.Oh|orinotcdPolyvinyl Chloride (CPVC)Pipe 'Nom 2in. diam (or smaller) SDR11OPVCpipe for use inclosed (process or supply) piping systems. B3.RiQ|d Nonmetallic Cmnduit(RNC)+ - Nom 2 in. diam (or smaller) Schedule 40 PVC conduit installed in aoonvdanoo with Article 347ofthe National Electrical Code (NFPA7O). B4.E|optr|ca| Nonmetallic Tubing VENTl+ ' Nom 2 in. diam (or smaller) PVC tubing installed in accordance with Article 331 nfthe National Electrical Code (NFPA7N. B5.C*oom Linked Polyethylene (PEX) Tubing - Nom 1 in. diam (or smaller) SDRQ PEX tubing for use in closed (pmooao or supply) piping systems. � C. Cables - Cables installed individually orinbundles with amax diam of2in. The following types and sizes ofcables may be used: Cl.Max 200 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with PVC insulation and jacketing. C2.Mux 3KC No. 30AVV8 (or smaller) aluminum urcopper conductor SER cable with PVC insulation and jacketing. C3.Max 3/C with ground No. 8 AWG (or smaller) Type NM (Romex) nonmetallic sheathed cable with PVC insulation and jacketing. C4.Max7/C No. 12 AVVG (or smaller) power/control cables with PVC insulation and jacketing. C5.Mex4pair No. 24AVVG (or smaller) copper conductor data cable with PVC insulation and jacketing. C6.Max RG/U coaxial cable with copper conductor and fluorinated ethylene insulation and jacket. C7.Max 4 pair No. 18 AWG (or smaller) copper conductor instrumentation cable with PVC insulation and jacketing. C8.Fiberoptic cable with PVC insulation and jacketing. C0.Through-Penetrmdn0Products* - Max 4/Cwith ground No. 20AVV8(or smaller) aluminum orcopper conductor, aluminum orsteel jacketed K4eta|'C|ad+orArmored-C|ad+cable. The TRating |s3/4hrunless copper pipe mrtube isused. When copper pipe wftube |mused, the hourly TRating |m1/2 hr. 3. Fill, Void or Cavity Material* - Sealant - Min 3/4 in. thickness of fill material applied within the annulus, flush with the top surface ofthe floor orchase wall sole plate. Min 5/8 in. thickness of fill material applied within the annulus, flush with bottom surface of gypsum board ceiling or chase wall top plate. Min 1/4 in. diam bead of fill material applied at point contact location on the top surface of floor or chase wall sole plate and at the penetrant/ceiling or penetrant/chase wall top plate interface. Specified Technologies Inc. -xSpeMSam*LC|Sealant ° Bearing the ULC|aaaihoadon Marking +Boeringthe ULLinting Mark Specified Technologles Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created orRevised: October 11.2OU2 (8oU99m'118n°(908s2080mn°FAX (9Ouoo1'8415"E'Mai|:toohaom@sti8mump.00m^Wabuimwmw.uihmstopxum FC-8U29 �A System No. F-C-3057 F Ratings - 1 Hr and 2 Hr (See Item 1) T Rating - 1/2 Hr Section A -A i i i 1. Floor - Ceiling Assembly - The 1 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F Rating of the firestop system is equal to the fire rating of the floor -ceiling assembly. The general construction features of the floor assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of opening is 3 in. B. Wood Joists - Nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. C. Gypsum Board* - Thickness, type, number of layers and fasteners as required in the individual Floor -Ceiling Design. Max diam of opening is 3 in. 1A. Chase Wall - (Optional, Not Shown) - The through penetrant (Item 2) may be routed through a 1 or 2 hr fire rated single, double or staggered wood stud/gypsum board chase wall. Depth of chase wall stud cavity to be min 1/2 in. greater than diameter of opening cut in sole and top plates to accommodate the through penetrant (Item 2). The chase wall shall be constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Nom 2 by 4 in., 2 by 6 in. or double nom 2 by 4 in. lumber studs. B. Sole Plate - Nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 3 in. C. Top Plate - The double top plate shall consist of two nom 2 by 4 in., two nom 2 by 6 in. or two sets of parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 3 in. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: June 14, 2004 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv®stifirestop.com • Website:www.stifirestop.com F-C-3057 PAGE 1 OF 2 D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as specified in the individual Wall and Partition Design. 2. Cables ~ Aog[egateC[O8S'Geotion@| area Ofcables within opening to be Dlax54 percent ofthe U[8SS-Seoti0D8| area Ofthe opening. Annular space tObemin 0in. (point contact) tOmax 1'1/4in. Penetrants bobg rigidly supported on both sides of floor -ceiling assembly, The following types and sizes of cables may be used: A. Max 200 pair NO. 24AVVG (o[ smaller) copper conductor telecommunication cable with PVC insulation and jacketing. B. Max 3/C No. 3/0 AVVG (or smaller) aluminum or copper cVnducb][8ER cable with PVC insulation and jacketing. � C. Max 3/C with ground No. 8 AWG (or smaller) Type NM (Romex) nonmetallic sheathed cable with PVC insulation and jacketing. D. Max 1/C - 350 kcnoi/ (or smaller) power cables with XLP insulation and jacketing. E. Max 7/CNo. 12AVVG(or smaller) power/control cables with PVC insulation and jacketing, F. Max RG/U (or smaller) copper conductor coaxial cable with fluorinated ethylene insulation and jacketing materials. G. Max pair No. 24AVVG (or smaller) copper conductor data cable with Hy|ar insulation and jacketing. H. Max pair No. 18AVVG (or smaller) copper conductor instrumentation cable with PVC insulation and jacketing. |. Fiber optic cable with PVC insulation and jacketing. 2A. Through Penetrating Product* - (Not Shown) As an alternate Item 3), one or more through -penetrating product to be installed within the opening. Max aggregate cross -sectional area of cables to be 52 percent of the cross -sectional area of the opening. Annular space between through -penetrating products and periphery ofopening tOb6min O in. (point contact) tomax 1-1/4 in. Through penetrating product rigidly supported on both sides of floor or wall assembly. The following types of through -penetrating products may be used: A. Max four copper conductors No. 2/0 AVVG (or smaller) aluminum or steel Armored Cob|m# or Metal -Clad Cab|m+. AFC CABLE SYSTEMS INC B. Two or more twisted copper conductors No. MAVVG (or smaller) Power Limited Circuit Cab|e+ with or without jacket under metal armor. AFC CABLE SYSTEMS INC C. Two or more twisted copper conductors No. 10 AWG (or smaller) Power Limited Fire Alarm Cable+ with orwithout a jacket under metal armor. AFC CABLE SYSTEMS INC D. Max two twisted copper conductors No. 12AVVG(or smaller) Non Power Limited Fire Alarm Cab|e+ with orwithout ajacket under emetal armor. AFC CABLE SYSTEMS INC 3. Fill, Void or Cavity Material* ' Sealant - Min 3/4 in. thickness of fill material applied within the annulus, flush with the top surface ofthe floor Orchase wall sole plate. Min 5/8in. thickness offill material applied within the annulus, flush with bottom surface of ceiling or chase vv@|| top plate. At point contact, min 1/4 in. diam bead Of fill material applied at cable bund|n/oubf|oororchase wall sole plate interface and at cable bundle/ceiling or chase wall top plate interface. SPECIFIED TECHNOLOGIES INC - *Bearing the UL Classification Mark Specified Technologies Inc. 200 Evans Way SomeiryUle, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created mRevised: June 14.2OO4 STI F(}3OS7