DOCUMENT Firestop submittal Pkg B-8445 3501 Fall River Rd 2009-05-11
Della Terra PROJECT: Della Terra Fall River Rd Estes Park CO DATE: May 11, 2009 SUBMITTED BY: david fisher fisher const. 1047 Iexington In estes park, CO 80517 V. Specified = Technologies STI® Inc. ("- FIRESTOP PRODUCTS 200 Evans Way • Somerville, NJ 08876 • (800) 992-1180 • (908) 526-8000 • Fax (908) 526-9623 # UL SYSTEM DESCRIPTION PRODUCT(S) 1 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. BLU Wrap Strip Wrap Strip Tuck -in. 2 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. BLU Wrap Strip Wrap Strip Tuck -in. 3 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. RED Wrap Strip Wrap Strip Tuck -in. 4 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. RED Wrap Strip Wrap Strip Tuck -in. 5 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. BLU2 Wrap Strip Wrap Strip Tuck -in. 6 FC2019 Max. 2" PVC or CPVC (DWV or closed), RNC, or ENT. BLU2 Wrap Strip Wrap Strip Tuck -in. 7 FC2044 Chase Wall Optional. Max. 2" PVC, CPVC or ABS RED Wrap Strip (DWV or closed) or RNC. Wrap Strip Tuck -in. 8 FC2044 Chase Wall Optional. Max. 2" PVC, CPVC or ABS RED Wrap Strip (DWV or closed) or RNC. Wrap Strip Tuck -in. GENERAL CERTIFICATE OF COMPLIANCE PRODUCT DATA SHEETS 1 SSWBLU 2 Intumescent Wrap Strip MATERIAL SAFETY DATA SHEETS 1 SSWBLU 2 Intumescent Wrap Strip 2 SSWBLU Intumescent Wrap Strip 3 SSWRED Intumescent Wrap Strip IMPORTANT NOTICE: This submittal is comprised of user selected documents that have been assembled using an automatic printing and archiving system. Use of the products or designs referenced herein are at the sole discretion of the installer, specifier, or other designated project decision maker. Specified Technologies Inc (STI) makes no guarantees nor recommendations regarding the applicability of the products or designs contained in this document to the referenced project. System No. F-C-2019 F Ratings - 1 and 2 Hr (See Item 1) T Ratings -1 and 2 Hr (See Item 1) L Rating At Ambient -1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diam of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-201 9 PAGE 2 OF 2 System No. F-C-2019 F Ratings -1 and 2 Hr (See Item 1) T Ratings -1 and 2 Hr (See Item 1) L Rating At Ambient -1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diam of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-201 9 PAGE 2 OF 2 System No. F-C-2019 F Ratings -1 and 2 Hr (See Item 1) T Ratings -1 and 2 Hr (See Item 1) L Rating At Ambient - 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft Section A -A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diam of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 2 OF 2 System No. F-C-2019 F Ratings -1 and 2 Hr (See Item 1) T Ratings -1 and 2 Hr (See Item 1) L Rating At Ambient -1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1 D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diam of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 2 OF 2 System No. F-C-2019 F Ratings -1 and 2 Hr (See Item 1) T Ratings - 1 and 2 Hr (See Item 1) L Rating At Ambient - 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series door -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diann of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-201 9 PAGE 2 OF 2 System No. F-C-2019 F Ratings -1 and 2 Hr (See Item 1) T Ratings -1 and 2 Hr (See Item 1) L Rating At Ambient -1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F and T Ratings of the firestop system are equal to the hourly fire rating of the floor -ceiling assembly. The general construction features of the floor -ceiling assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. (76 mm). B. Wood Joists* - For 1 hr fire -rated floor -ceiling assemblies, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor -ceiling assemblies, nom 2 by 10 in. (51 by 102 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor -Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* - Nom 4 ft (1220 mm) wide by 5/8 in. (16 mm) thick as specified in the individual Floor -Ceiling Design. First layer of gypsum board secured to wood joists or furring channels as specified in the individual Floor -Ceiling Design. Second layer of gypsum board (2 hr fire -rated assembly) screw -attached to furring channels as specified in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). 2. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the system. Diam of openings hole -sawed through flooring system and through gypsum board ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENMT)+ - Nom 2 in. (51 mm) diam (or smaller) ENMT formed from PVC and installed in accordance with Article 331 of the National Electrical Code. Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 .�. Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-201 9 PAGE 1 OF 2 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/8 or 3/16 in. (3.2 or 4.8 mm) thick intumescent material faced on both sides with a plastic film, supplied in 2 in. (51 mm) wide strips or nom 1/4 in. (6 mm) thick intumescent material faced on both sides with a plastic film, supplied in 1-1/2 in. (51 mm) wide strips. One layer of wrap strip is wrapped around the through -penetrant at its egress from both sides of the floor -ceiling assembly with ends butted and held in place with two layers of 2 in. (51 mm) wide by 3 mil (0.08 mm) thick aluminum foil tape. The bottom edge of the wrap strip shall extend 5/8 in. (16 mm) below the flooring system and 1/4 in. (6 mm) below the ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal BLU Wrap Strip, SpecSeal BLU2 Wrap Strip or SpecSeal RED Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2019 PAGE 2 OF 2 A System No. F-C-2044 F Ratings - 1 Hr and 2 Hr (See Item 1) T Ratings - 1/4 and 1 Hr (See Item 3) Section A -A 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F Rating of the firestop system is equal to the fire rating of the floor -ceiling assembly. The general construction features of the floor assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. B. Wood Joists - Nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Gypsum Board* - Thickness, type, number of layers and fasteners as required in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). D. Furring Channel - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring channels installed perpendicular to wood joists between base and face layers of gypsum board (Item C). Furring channels spaced max 24 in. (610 mm) OC with additional short lengths of furring channel installed adjacent to and max 3 in. (76 mm) from two opposing sides of penetrant. 2. Chase Wall - (Optional, Not Shown) - The through -penetrant (Item 3) may be routed through a 1 or 2 hr fire rated single, double or staggered wood stud/gypsum board chase wall constructed of the materials and in the manner specified in individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall have the following construction details: A. Studs - Nom 2 by 4 in. (51 by 102 mm) , 2 by 6 in. (51 by 152 mm) or double nom 2 by 4 in. (51 by 102 mm) lumber studs. B. Sole Plate - Nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. C. Top Plate - The double top plate shall consist of two nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or two sets of parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 3 in. (76 mm). D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2044 PAGE 1 OF 2 3. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the firestop system. Diam of openings hole -sawed through flooring system and through gypsum wallboard ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. C. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). D. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR17 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. The T Rating is 1 hr in when max 1 in. (25 mm) diam pipe is used. When pipe larger than 1 in. (25 mm) diam is used, the T Rating is 1/4 hr. 4. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/4 in. (6 mm) thick by 1-1/2 in. (38 mm) wide intumescent strip (RED), nom 1/8 in. (3.2 mm) by 2 in. (51 mm) wide intumescent strip (BLU2), or nom 3/16 in. (4.8 mm) by 2 in. (51 mm) wide intumescent strip (BLU) faced on both sides with a plastic film. One layer of wrap strip is wrapped around the through -penetrant at its egress from bottom surface of ceiling or lower top plate of chase wall assembly with ends butted and held in place with a single wrap of aluminum foil tape. The bottom edge of the wrap strip shall extend 1/4 in. (6 mm) below the bottom surface of ceiling or the lower top plate of chase wall assembly. SPECIFIED TECHNOLOGIES INC - SpecSeal RED, BLU, or BLU2 Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling or lower top plate of chase wall assembly. Additional fill material to be installed to form a min 1/4 in. (6 mm) crown around wrap strip at its egress from bottom surface of ceiling or lower top plate of chase wall assembly. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2044 PAGE 2 OF 2 A System No. F-C-2044 F Ratings - 1 Hr and 2 Hr (See Item 1) T Ratings - 1/4 and 1 Hr (See Item 3) • 4B 111111111 Section A -A 4B 1. Floor -Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor -Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor -ceiling assembly shall be constructed of the materials and in the manner specified in Design Nos. L505, L511 or L536 in the UL Fire Resistance Directory. The F Rating of the firestop system is equal to the fire rating of the floor -ceiling assembly. The general construction features of the floor assembly are summarized below: A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor -Ceiling Design. Max diam of floor opening is 3 in. B. Wood Joists - Nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Gypsum Board* - Thickness, type, number of layers and fasteners as required in the individual Floor -Ceiling Design. Max diam of ceiling opening is 3 in. (76 mm). D. Furring Channel - (Not Shown) - In 2 hr fire -rated assemblies, resilient galv steel furring channels installed perpendicular to wood joists between base and face layers of gypsum board (Item C). Furring channels spaced max 24 in. (610 mm) OC with additional short lengths of furring channel installed adjacent to and max 3 in. (76 mm) from two opposing sides of penetrant. 2. Chase Wall - (Optional, Not Shown) - The through -penetrant (Item 3) may be routed through a 1 or 2 hr fire rated single, double or staggered wood stud/gypsum board chase wall constructed of the materials and in the manner specified in individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall have the following construction details: A. Studs - Nom 2 by 4 in. (51 by 102 mm) , 2 by 6 in. (51 by 152 mm) or double nom 2 by 4 in. (51 by 102 mm) lumber studs. B. Sole Plate - Nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. C. Top Plate - The double top plate shall consist of two nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or two sets of parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 3 in. (76 mm). D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. STI Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2044 PAGE 1 OF 2 3. Through Penetrants - One nonmetallic pipe or conduit to be installed approximately midway between wood joists and centered within the firestop system. Diann of openings hole -sawed through flooring system and through gypsum wallboard ceiling to be nom 5/8 in. (16 mm) larger than the outside diam of through -penetrant. Pipe or conduit to be rigidly supported on both sides of the floor -ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. C. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). D. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR17 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. The T Rating is 1 hr in when max 1 in. (25 mm) diam pipe is used. When pipe larger than 1 in. (25 mm) diam is used, the T Rating is 1/4 hr. 4. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - Wrap Strip - Nom 1/4 in. (6 mm) thick by 1-1/2 in. (38 mm) wide intumescent strip (RED), nom 1/8 in. (3.2 mm) by 2 in. (51 mm) wide intumescent strip (BLU2), or nom 3/16 in. (4.8 mm) by 2 in. (51 mm) wide intumescent strip (BLU) faced on both sides with a plastic film. One layer of wrap strip is wrapped around the through -penetrant at its egress from bottom surface of ceiling or lower top plate of chase wall assembly with ends butted and held in place with a single wrap of aluminum foil tape. The bottom edge of the wrap strip shall extend 1/4 in. (6 mm) below the bottom surface of ceiling or the lower top plate of chase wall assembly. SPECIFIED TECHNOLOGIES INC - SpecSeal RED, BLU, or BLU2 Wrap Strip B. Fill, Void or Cavity Material* - Sealant - Fill material forced into annulus to fill space to max extent possible, flush with top surface of floor and bottom surface of ceiling or lower top plate of chase wall assembly. Additional fill material to be installed to form a min 1/4 in. (6 mm) crown around wrap strip at its egress from bottom surface of ceiling or lower top plate of chase wall assembly. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking 111111111111111111 STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: January 2, 2009 (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:www.stifirestop.com F-C-2044 PAGE 2 OF 2 Specified — Technologies STI Inc. GENERAL CERTIFICATE of CONFORMANCE Description: SpecSeal® Firestop Products Included Products: Series SSS Intumescent Sealant Series LCI Intumescent Sealant Series LC Latex Endothermic Sealant Series SSP Intumescent Putty Series EP Power ShieldTM Box Insert Series SSWRED Intumescent Wrap Strips Series SSWBLU Intumescent Wrap Strips Series SSC Intumescent Firestop Collars Series LCC Intumescent Firestop Collars 200 Evans Way, Suite 2 Somerville, N .J. 08876 Phone: (908) 526-8000 Fax: (908) 526-9623 Toll Free: (800) 992-1180 Series SSB Intumescent Firestop Pillows Series ASI00 Elastomeric Spray Series AS200 Elastomeric Spray Series ES100 Elastomeric Sealant Series SSMFirestop Mortar Pensil Series PEN200 Silicone Foam Pensil Series PEN300 Silicone Sealant Pensil Series PEN300SL Silicone Sealant These products are tested to the following standards where applicable: ASTM STANDARD: E 814 Fire Tests of Through -Penetration Fire Stops E 119 Fire Tests of Building Construction and Materials E 1966 Fire -Resistive Joint Systems E 84 Surface Burning Characteristics of Building Materials E 1399 Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems UL STANDARD 1479 Fire Tests of Through -Penetration Firestops 263 Fire Tests of Building Construction and Materials 2079 Tests for Fire -Resistance of Building Joint Systems 723 Tests for Surface Burning Characteristics of Building Materials Chemical Content Statements: No asbestos, PCB's or water-soluble intumescent ingredients are used or contained in these products. James P. Stahl, Jr. Technical Manager February 1, 2002 Date E5 j�ll�lil IIl! SERIES SSW INTUMESCENT WRAP STRIPS APPLICATIONS SpecSeal® Wrap Strips are used for firestop- ping combustible penetrants such as nonmetal- lic pipes or pipe insulation. Installations were developed for both "tuck -in" applications (where strips are secured around the penetrant and slid into the opening) and restraining collar assemblies (for surface mount- ing). For larger openings or complex penetrant configurations, systems were developed utilizing wrap strips in conjunction with other SpecSeal® products. SpecSeal® Wrap Strips are suitable for use in all common forms of construction including concrete floors, concrete over steel deck, concrete walls, concrete block walls, gypsum board/stud walls, and wood floor/ceiling assemblies. PERFORMANCE PRODUCT DESCRIPTION SpecSeal® Wrap Strips are highly flexible, elastomeric strips designed to firestop combustible penetrations in fire -rated floors, floor/ceilings, and walls. Convenient 12' (3.7 m) rolls, or individu- ally sized strips facilitate installation and minimize waste. Four grades are available to suit the product to the application. These products utilize STI's fast responding intumescent technology, providing very responsive and highly directionalized expansion. Rapid expansion provides quick closure for burning com- bustible penetrants. When exposed to temperatures in excess of 250° F (121° C), the SpecSeal® Wrap Strip begins to expand (intumesce) rapidly to form a dense, highly insulative char. Free expansion varies according to the grade utilized (See Table A). Expansion continues up to temperatures of 1,000° F (538° C). • Rapid Expansion: • High Volume Char: • Water -Resistant: • Economical: • Highly Flexible: • Versatile: Closes off burning penetrants faster. Significant expansion seals off opening! No soluble or hygroscopic ingredients. 12' (3.2 m) rolls or precut strips means no piecing... less waste! No foil... soft...supple...easier to install! Performer for a wide range of complex applications. SpecSeal® Wrap Strips are the basis for systems that meet the exacting criteria of ASTM E 814 (UL1479). Systems were tested for all common forms of construction and penetrants with ratings up to 3 and 4 hours (dependent upon grade of wrap strip utilized). PHYSICAL PROPERTIES Gv°'S oo US 3L73 FILL VOID 0R CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORES INC.8 FOR USE 01 THROUGH•PENETRATDB FIRESTOP SYSTEMS. SEE UL FIRE RESISTANCE DIRECTORY APPROVED See Table A. This material is extremely stable. Long term aging studies indicate no significant loss of physical properties nor significant change in expansion properties after eleva ed temperature, humidity, and immersion testing. Consult factory for additional information. Catalog Number SSWBLU SSWBLU2 SSWRED SSWRED2 SSWBLU220 SSWBLU230 SSWBLU240 SSW125 SSW250 SSW375 Color Blue Blue Red Red Blue Blue Blue Gray Gray Gray Thickness 3/16° (4.8 mm) 1/8" (3.2 mm) 1/4" (6 ram) 118° (3.2 mm) 1/8° (3.2 mm) 1/8° (3.2 mm) 118" (3.2 mm) 1/8" (3.2 mm) 1/4' (6 mm) 3/8° (10 mm) Width 2° (51 mm) 2° (51 mm) 1-1/2° (38 mm) 1-1/2" (38 mm) 1.1/2° (38 mm) 3° (76 ram) 4° (102 mm) 1.1/2' (38 ram) 1-1/2° (38 mm) 1.1/2° (38 mm) Length 12' (3.7 m) 12' (3.7 m) 12' (3.7 m) 12'(3.7 m) 8° (204 mm) 11-3/16"(284 mm) 14-518"(356 mm) 8° (204 mm) 11-314"(298 mm) 15-7/8° (403 mm) Weight 3.0 Ibs (1.4 kg) 0.7 lbs (0.32 kg) 1.10 Ibs (0.52 kg) 1.10 Ibs (0.52 kg) 0.05 Ibs (0.02 kg) 0.15Ibs (0.08 kg) 0.3 lbs (0.12 kg) 0.05 Ibs (0.02 kg) 0.2 Ibs (0.10 kg) 0.4 Ibs (0.18 kg) Expansion System Two -Stage Single Stage Two -Stage Single Stage Single Stage Single Stage Single Stage Single Stage Single Stage Single Stage Expansion Begins 350° F (160° C) 2nd Stage 320° F (160° C) 350° (160° ) 2nd Stage 320° F (160° C) 320° F (160° C) 320° F (160° C) 320° F (160° C) 320° F (160° C) 320° F (160° C) 320° F (160° C) Volume Expansion 20 to 30x 30 to 60x 16 to 24x 24 to 48x 30 to 60x 30 to 60x 30 to 60x 30 to 60x 30 to 60x 30 to 60x In Service Temp 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) 130°F (54°C) Oven Aging No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Change (60°C) No Charge (60°C) Humidity Exposure No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) No Change (60° C; 98% R.H.) ULAccelerating Aging Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass V Technical Service 1-800-992-1180 STI. www.stifirestop.com " ' " ' " et • Series SSW Intumescent Wrap Strip • FOD-5092 06/2007 SPECIFICATIONS The wrap strip material shall be highly flexible, intumescent material. The wrap strip shall contain no water soluble expansion ingredients and provide a minimum of 16x free expansion. The intumescent wrap strip shall be faced on each side with plastic. The specified material shall be approved for a wide range of applications including combustible and noncombustible penetrants when used by itself or in combination with other products from the same manufacturer. The wrap strip shall be UL Classified and tested to the requirements of ASTM E 814 (UL1479). SPECIFIED DIVISIONS DIV. 7 — 07 84 00 — Fireslopping DIV. 22 — 22 07 00 — Plumbing Insulation DIV. 22 — 22 00 00 — Plumbing DIV. 23 — 23 07 00 — HVAC Insulation INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be free of oil, loose dirt, rust, or scale. In most cases, walls require symmetrical applications and wrap strips must be applied to both sides. Wrap strips may be continuously wrapped or installed individually around the penetrant. When layers are installed individually, butted ends in successive layers may be aligned or offset. When selecting a wrap strip grade, refer to TABLE B below. i rOP.,,,'z%ri'lr,„r?, f ' ,i ,.,,,,,f�,rli, / ,✓ iNp ,Ocr "/ ' f''''y lk' r z„' .fr h? rrriv,r ., SSWRED SSWRED2 SSWBLU SSWBLU2 Max. Plastic Pipe Size 6" (152 mm) 6" (152 mm) 12" (305 mm) 12" (305 mm) SYSTEM SELECTION: A variety of methods have been developed and System Selection: A variety of methods have been developed and UL Classified using SpecSeal® Wrap Strips. Visit the Technical Library at WWW slwdil stpp;.gpm to locate precise system installation drawings. TUCK -IN INSTALLATIONS: Encircle penetrant with wrap strip. Masking tape may be used to temporarily secure wrap strip. Secure wrap strip layers in place using steel tie wire or foil tape as required. Slide wrap strip into opening and position dictated by individual UL System or STI design. Apply SpecSeal® Sealant as required for smoke seal. RESTRAINING COLLAR INSTALLATIONS: When surface mounted restraining collar systems are used, start by installing SpecSeal® Sealant into annular space as a smoke seal. Although not always required by the UL System, sealing both sides of walls and floors is a recommended practice. Encircle penetrant with wrap strip layers. Temporarily secure layers using masking tape or steel wire. Calculate the length of restraining collar required to completely wrap around the outer diameter of the wrap strip layers plus an additional 1" (25 mm) overlap. Secure restraining collars with stainless steel hose clamp positioned at the mid -point of the collar or symmetrically located steel screws as specified within the UL System. Refer to TABLE C below to select appropriate restraining collar. /q/i +'Gilr / r ter �r�r,.�rr,,,�i,i�f..r,�o,l r fryrs r�gw rrilkg' (� riiyir r%/,/r rl/pr ✓ / r, yri s 0 00 hr„�; i a rirrv>i/or/,%, re, tit/ ",4 SSWRED SSWRED2 SSWBLU SSWBLU2 SSWRC X X SSWRC2 X X WSC-8* X X WSC-BRED** X X WSC-12*** X X SSWRC and SSWRC2 sold in 25' (7.6 m) rolls and may be cut to length as required 'Single collar for 6" (152 mm) and 8" (204 mm) pipe only "Single collar for 6" (152 mm) pipe only **'Single collar for 10" (254 mm) and 12" (305 mm) pipe only For more information, refer to STI's "Product Estimation and Installation Sheet — Wrap Strip Collars" concerning the use of restraining collar. POURED OR EMBEDDED INSTALLATIONS: Where excessive annular space exists, poured or embedded installations provide an economical method of sealing large openings. Encircle penentrants with appropriate number of wrap strip layers securing wrap strip layers with steel tie wire or foil tape as required. In floors, locate the bottom edge of wrap strip at the position specified in the UL System. In walls, locate the exposed edge of wrap strip at the position specified in the UL System. After wrap strips are secured and positioned, back till openings with SpecSeal® Firestop Mortar or Sealant as required. 2 STI Product Data Sheet • Series SSW Intumescent Wrap Strip • FOD-5092 06/2007 Technical Service 1-800.992-1180 www*stifirestop.com STI. These tables provide the information related to the firestopping of plastic pipes utilizing "tuck -in" or restraining collar assemblies. 1. Number of layers. 2. Length of each layer and total number of required layers. 3. Length of restraining collar metal (with 1" (25 mm) min. added for overlap). Trade Size SSWRED Pipe OD WRAP STRIP AND RESTRAINING COLLAR Length of Layers & Restraining REQUIREMENTS Collar (RC) In Inches* 1st 2nd 3rd Total RC 1.5 1.9 7.5 7.5 8.7 2.0 2.4 9.1 9.1 10.3 2.5 2.9 10.7 12.3 22.9 13.6 3.0 3.5 12.6 14.1 26.7 15.5 3.5 4.0 14.1 15.7 17.3 47.1 18.7 4.0 4.5 15.7 17.3 18.8 51.8 20.3 6.0 6.63 22.4 24.0 25.5 143.7' 27.22 'Regv;resdwnegecko( 3 Layars olwrapsrq 'Regrars WSCBR ED reshanig cot. kaki_ ia trade sle ppe Trade Size SSWBLU Pipe OD WRAP STRIP AND RESTRAINING COLLAR Length of Layers & Restraining REQUIREMENTS Collar (RC) In Inches* 1st 2nd 3rd 4th 5th Total RC 1.5 1.9 7.1 7.1 8.3 2.0 2.4 8.7 8.7 9.9 2.5 2.9 10.3 11.5 21.8 12.8 3.0 3.5 12.2 13.4 25.5 14.7 3.5 4.0 13.7 14.9 16.1 44.8 17.5 4.0 4.5 15.3 16.5 17.7 49.5 19.1 6.0 6.63 22.0 23.2 24.3 139.0' 26.0' 8.0 8.63 28.3 29.5 30.6 31.8 240.32 32.82 10.0 10.75 35.0 36.1 37.3 38.5 367.23 39.63 12.0 12.75 41.2 42.4 43.6 44.8 45.9 544.94 47.34 Requires two stacks of 3 layers of wr p strip and WSC8 restraining collar. 'Requires two stacks of 4 layers of wrap strip and WSC8 restraining collar. Requires 2-1n sla ks of 4 layers of p strip and WSC12 restraining cotter. Requires 2-112 sta ks of 5 Layers of wr p strip and WSC12 restraining collar. SSWRED2 Trade Size and Pipe OD SSWBLU2 WRAP STRIP AND RESTRAINING COLLAR IEQUIREMENTS Length of Layers & Restraining Collar (RC) In Inches* 1st 2nd 3rd 4th 5th Total RC 1.5 1.9 6.8 6.8 7.9 2.0 2.4 8.3 8.3 9.5 2.5 2.9 9.9 10.7 20.6 11.9 3.0 3.5 11.8 12.6 24.3 13.9 3.5 4.0 13.4 14.1 14.9 42.4 16.3 4.0 4.5 14.9 15.7 16.5 47.1 17.9 6.0 6.63 21.6 22.4 23.2 134.3' 24.7' 8.0 8.63 27.9 28.7 29.5 30.2 232.52 31.12 10.0 10.75 34.6 35.3 36.1 36.9 357.43 38.03 12.0 12.75 40.8 41.6 42.4 43.2 44.0 530.14 45.34 Requires two stacks of 3 layers of wrap slip a d 1YSC8 restraining otter. 'Requires two stacks of 4 layers (map strip and WSC8 restraining collar. Requires 2-1/2 stacks of 4 layers of wrap strip nd WSC8RED orW C12 restraining collar. Requires 2-1/2 stacks of 5 layers of wrap strip nd WSC12 restrains g collar. ' Metric dimensions available online at www.stirirestop.com. RESTRAINING COLLAR INSTALLATION Retainer Tabs Mounting Tabs 1.Temporarily secure wrap strips to pipe with masking tape. Measure and cut collar to length, providing a 1" (25 mm) overlap. 2. Bend mounting tabs 90° away from collar. Tightly secure to pipe or conduit with three #8 sheet metal screws or one stainless steel hose clamp. 3. Bend retainer tabs 90° toward pipe or conduit. Tabs may be bent flush against pipe or trimmed to a length sufficient to contain all wrap strip layers. 4. Slide collar against floor or wall and secure with appropriate steel fasteners and fender washers Technical Service 1-800-992-1180 STI. www,stifirestop.com STI Product Data Sheet • Series SSW Intumescent Wrap Strip • FOD-5092 06/2007 3 MAINTENANCE Inspection: Installations should be inspected periodically for subsequent damage. Any damage should be repaired using SpecSeal® products per the original approved design. TECHNICAL SERVICE Specified Technologies, Inc. provides toll free technical support to assist in product selection and installation design. Log onto the Technical Library at www,sd_'u)'ites)opccrm or call the STI Technical Service Department to obtain UL System drawings, MSDSs, or other technical information. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. Wash areas of skin contact with soap and water. Avoid contact with eyes. AVAILABILITY SpecSeal® Wrap Strips are available from authorized distributors. Consult factory for the names and locations of the nearest sales representatives or distributors. w i%/r// rrrs' �ri,;, i k✓�, fy „. ,✓l�, ., .r�. %lr��r. ,�.. ,.,L er,�„u„ H;t',AF; 4 "' , 1, rr/rr,j✓5�,,/�, r,,�'A ) „„ A r rr/�i i/ A,ea0 rrn;,:, k RED & RED2 Wrap Strip & Accessories SSWRED 12' x 1-1/2" x 1/4" (3.7 m x 38 mm x 6 mm) Intumescent Wrap Strip SSWRED2 12' x 1-1/2" x 1/8" (3.7 m x 38 mm x 3 mm) Intumescent Wrap Strip SSWRC2 30 Gauge sheet metal restraining collar for 54" (102 mm) pipes (25' (7.6 m) roll) WSC-8RED Preformed restraining collar for 6" (152 mm) pipe BLU & BLU2 Wrap Strip & Accessories SSWBLU 12' x 2" x 3/16" (3.7 m x 51 mm x 5 mm) Intumescent Wrap Strip SSWBLU2 12' x 2" x 1/8" (3.7 m x 51 mm x 3 mm) Intumescent Wrap Strip SSWRC 30 Gauge sheet metal restraining collar for 5.4" (102 mm) pipes (25' (7.6 m) roll) WSC-8 Preformed restraining collar for 6" (152 mm) and 8" (204 mm) pipe WSC-12 Preformed restraining collar for 10" (254 mm) and 12" (305 mm) pipe Precut Wrap Strips SSW125 1-1/2" (38 mm) x 1/8" (3 mm) strip sized for 2° (51 mm) trade size pipe SSW250 1-1/2" (38 mm) x 1/4" (6 mm) strip sized for 3" (76 mm) trade size pipe SSW375 1-1/2" (38 mm) x 3/8" (10 mm) strip sized for 4" (102 mm) trade size pipe SSWBLU220 Precut strip sized for 2" (51 mm) trade size pipe SSWBLU230 Precut strip sized for 3" (76 mm) trade size pipe SSWBLU240 Precut strip sized for 4" (102 mm) trade size pipe CITY OF NEW YORK MEA 130-96 M & MEA 212-01-M IMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed. WARRANTY Specified Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt no6fig6on, will at its option, exchange or repair the goods or refund the purchase price. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA — COPYRIGHT © 2008 SPECIFIED TECHNOLOGIES, INC. STI Specified Technologies Inc. Specified Technologies Inc. • 200 Evans Way, Somerville NJ 08876 • Phone: 800.992.1180 • Fax: 908.526.9623 4 STI Product Data Sheet • Series SSW Intumescent Wrap Strip • FOD-5092 06/2007 Technical Service 1-800-992-1180 www.stifirestop.com STI. _ _ -_-- -- STI. Material Safety Data Sheet 14-AUG-2006 SpecSeal® BLU2 WRAP STRIP CHEMICAL PRODUCT/COMPANY IDENTIFICATION Material Identification PRODUCT NAME SpecSeal® BLU2 Wrap Strip, SSWBLU220, SSWBLU230, SSWBLU240 CHEMICAL FAMILY Does not apply Company Identification MANUFACTURER/DISTRIBUTOR Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 PHONE NUMBERS Product Information : 1-908-526-8000 Emergency : 1-800-255-3924 COMPOSITION/INFORMATION ON INGREDIENTS Non -hazardous, flexible rubber strip. HAZARDS IDENTIFICATION ***********EMERGENCY OVERVIEW****** * Non -hazardous. Flexible rubber strip * ************************************************ Potential Health Effects: EYE: Physical contact may cause irritation. SKIN: Contact should not cause problems. INGESTION: Not likely. INHALATION: No hazard. CHRONIC (CANCER) INFORMATION: None known. LONG TERM TOXIC EFFECTS: None known. Page 1 of 3 MSDS - SpecSeal® BLU2 Wrap Strip FOD-5088 FIRST AID MEASURES First Aid INHALATION: None applicable. SKIN CONTACT: None applicable. EYE CONTACT: Irrigate eyes with running water for at least 15 minutes. Get medical attention if irritation develops. INGESTION: None applicable. FIRE FIGHTING MEASURES Flash point: Not established. EXTINGUISHING MEDIA Dry Chemical; Carbon Dioxide; Foam; Water spray for large fires. SPECIAL FIRE FIGHTING PROCEDURES: As for surrounding fire. ACCIDENTAL RELEASE MEASURES Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE EQUIPMENT during clean-up. HANDLING AND STORAGE Store under ambient conditions. No special handling required. EXPOSURE CONTROLS/PERSONAL PROTECTION EYE PROTECTION REQUIREMENTS: Safety glasses/goggles. SKIN PROTECTION REQUIREMENTS: None. RESPIRATOR REQUIREMENTS: None. VENTILATION REQUIREMENTS. If needed, use local exhaust ventilation to keep airborne concentrations below the TLV. Exposure Guidelines Exposure Limits None. PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL FORM Flexible rubber strip SPECIFIC GRAVITY 1.38 PERCENT VOLATILES 0 SOLUBILITY IN WATER Insoluble STABILITY AND REACTIVITY STABILITY: This is a stable material. CONDITIONS TO AVOID None. HAZARDOUS POLYMERIZATION: Will not occur. INCOMPATIBILITIES• None special. TOXICOLOGICAL INFORMATION Mixture not tested but based on components: Particles may cause physical irritation to eyes. Contains no carcinogens as specified by IARC, ACGIH and NTP or OSHA. Page 2 of 3 MSDS - SpecSeal® BLU2 Wrap Strip FOD-5088 ECOLOGICAL INFORMATION No data but not expected to be environmental hazard. DISPOSAL CONSIDERATIONS Waste Disposal: Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations. TRANSPORTATION INFORMATION DOT — not regulated. REGULATORY INFORMATION U.S. Federal Regulations TSCA Inventory Status: Article. Section 313 Supplier Notifications. This product contains no toxic chemicals subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right -To -Know Act of 1986 and of 40 CFR 372: OTHER INFORMATION NPCA-HMIS Rating Health :0 Flammability : 1 Reactivity :0 Personal Protection rating to be supplied by user depending on use conditions. STATE RIGHT -TO -KNOW LAWS No substances on the state hazardous substances list, for the states indicated below, are used in the manufacture of products on this Material Safety Data Sheet, with the exceptions indicated. While we do not specifically analyze these products, or the raw materials used in their manufacture, for substances on various state hazardous substances lists, to the best of our knowledge the products on this Material Safety Data Sheet contain no such substances except for those specifically listed below: SUBSTANCES ON THE NEW JERSEY WORKPLACE HAZARDOUS SUBSTANCE LIST PRESENT AT A CONCENTRATION OF 1 % OR MORE (0.1% FOR SUBSTANCES IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): NJTSRN-SSWBLU2. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER: May contain traces of substances known to the State of California to cause cancer. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM: None known. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the data compiled. However, no representation, warranty, or guarantee is made as to its accuracy, reliability or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur form the use of this information. Responsibility for MSDS : Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 Page 3 of 3 MSDS - SpecSeal® BLU2 Wrap Strip FOD-5088 - -_-,-.-_-_- ____ STL Material Safety Data Sheet 01-JAN-2003 SpecSeal® BLU WRAP STRIP CHEMICAL PRODUCT/COMPANY IDENTIFICATION Material Identification PRODUCT NAME SpecSeal® BLU Wrap Strip CHEMICAL FAMILY Does not apply Company Identification MANUFACTURER/DISTRIBUTOR Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 PHONE NUMBERS Product Information : 1-908-526-8000 Emergency : 1-800-255-3924 COMPOSITION/INFORMATION ON INGREDIENTS Non -hazardous, flexible rubber strip. HAZARDS IDENTIFICATION ***********EMERGENCY OVERVIEW****** * Non -hazardous. Flexible rubber strip * ************************************************ Potential Health Effects: EYE: Physical contact may cause irritation. SKIN: Contact should not cause problems. INGESTION: Not likely. INHALATION: No hazard. CHRONIC (CANCER) INFORMATION: None known. LONG TERM TOXIC EFFECTS: None known. Page 1 of 3 MSDS - SpecSeal® BLU Wrap Strip FOD-5020 FIRST AID MEASURES First Aid INHALATION: None applicable. SKIN CONTACT: None applicable. EYE CONTACT: Irrigate eyes with running water for at least 15 minutes. Get medical attention if irritation develops. INGESTION: None applicable. FIRE FIGHTING MEASURES Flash point: Not established. EXTINGUISHING MEDIA Dry Chemical; Carbon Dioxide; Foam; Water spray for large fires. SPECIAL FIRE FIGHTING PROCEDURES: As for surrounding fire. ACCIDENTAL RELEASE MEASURES Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE EQUIPMENT during clean-up. HANDLING AND STORAGE Store under ambient conditions. No special handling required. EXPOSURE CONTROLS/PERSONAL PROTECTION EYE PROTECTION REQUIREMENTS. Safety glasses/goggles. SKIN PROTECTION REQUIREMENTS: None. RESPIRATOR REQUIREMENTS: None. VENTILATION REQUIREMENTS: If needed, use local exhaust ventilation to keep airborne concentrations below the TLV. Exposure Guidelines Exposure Limits None. PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL FORM Flexible rubber strip SPECIFIC GRAVITY 1.38 PERCENT VOLATILES 0 SOLUBILITY IN WATER Insoluble STABILITY AND REACTIVITY STABILITY: This is a stable material. CONDITIONS TO AVOID None. HAZARDOUS POLYMERIZATION Will not occur. INCOMPATIBILITIES. None special. TOXICOLOGICAL INFORMATION Mixture not tested but based on components: Particles may cause physical irritation to eyes. Contains no carcinogens as specified by IARC, ACGIH and NTP or OSHA. Page 2 of 3 MSDS - SpecSeal® BLU Wrap Strip FOD-5020 ECOLOGICAL INFORMATION No data but not expected to be environmental hazard. DISPOSAL CONSIDERATIONS Waste Disposal: Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations. TRANSPORTATION INFORMATION DOT — not regulated. REGULATORY INFORMATION U.S. Federal Regulations TSCA Inventory Status: Article. Section 313 Supplier Notifications. This product contains no toxic chemicals subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right -To -Know Act of 1986 and of 40 CFR 372: OTHER INFORMATION NPCA-HMIS Rating Health :0 Flammability : 1 Reactivity :0 Personal Protection rating to be supplied by user depending on use conditions. STATE RIGHT -TO -KNOW LAWS No substances on the state hazardous substances list, for the states indicated below, are used in the manufacture of products on this Material Safety Data Sheet, with the exceptions indicated. While we do not specifically analyze these products, or the raw materials used in their manufacture, for substances on various state hazardous substances lists, to the best of our knowledge the products on this Material Safety Data Sheet contain no such substances except for those specifically listed below: SUBSTANCES ON THE NEW JERSEY WORKPLACE HAZARDOUS SUBSTANCE LIST PRESENT AT A CONCENTRATION OF 1% OR MORE (0,1% FOR SUBSTANCES IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): NJTSRN-SSWBLU. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER: May contain traces of substances known to the State of California to cause cancer. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM: None known. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the data compiled. However, no representation, warranty, or guarantee is made as to its accuracy, reliability or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur form the use of this information. Responsibility for MSDS : Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 Page 3 of 3 MSDS - SpecSeal® BLU Wrap Strip FOD-5020 _ _ _ --_. ....... ...._ STL Material Safety Data Sheet 01-JAN-2006 SpecSeal® RED WRAP STRIP CHEMICAL PRODUCT/COMPANY IDENTIFICATION Material Identification PRODUCT NAME SpecSeal® RED Wrap Strip CHEMICAL FAMILY Does not apply Company Identification MANUFACTURER/DISTRIBUTOR Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 PHONE NUMBERS Product Information : 1-908-526-8000 Emergency : 1-800-255-3924 COMPOSITION/INFORMATION ON INGREDIENTS Non -hazardous, flexible rubber strip. HAZARDS IDENTIFICATION ***********EMERGENCY OVERVIEW****** * Non -hazardous. Flexible rubber strip * ************************************************ Potential Health Effects: EYE: Physical contact may cause irritation. SKIN: Contact should not cause problems. INGESTION: Not likely. INHALATION: No hazard. CHRONIC (CANCER) INFORMATION: None known. LONG TERM TOXIC EFFECTS: None known. Page 1 of 3 MSDS - SpecSeal® RED Wrap Strip FOD-5018 FIRST AID MEASURES First Aid INHALATION: None applicable. SKIN CONTACT: None applicable. EYE CONTACT: Irrigate eyes with running water for at least 15 minutes. Get medical attention if irritation develops. INGESTION: None applicable. FIRE FIGHTING MEASURES Flash point: Not established. EXTINGUISHING MEDIA Dry Chemical; Carbon Dioxide; Foam; Water spray for large fires. SPECIAL FIRE FIGHTING PROCEDURES• As for surrounding fire. ACCIDENTAL RELEASE MEASURES Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE EQUIPMENT during clean-up. HANDLING AND STORAGE Store under ambient conditions. No special handling required. EXPOSURE CONTROLS/PERSONAL PROTECTION EYE PROTECTION REQUIREMENTS• Safety glasses/goggles. SKIN PROTECTION REQUIREMENTS: None. RESPIRATOR REQUIREMENTS: None. VENTILATION REQUIREMENTS• If needed, use local exhaust ventilation to keep airborne concentrations below the TLV. Exposure Guidelines Exposure Limits None. PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL FORM Red flexible solid rubber strip SPECIFIC GRAVITY 1.38 PERCENT VOLATILES 0 SOLUBILITY IN WATER Insoluble STABILITY AND REACTIVITY STABILITY: This is a stable material. CONDITIONS TO AVOID None. HAZARDOUS POLYMERIZATION• Will not occur. INCOMPATIBILITIES• None special. TOXICOLOGICAL INFORMATION Mixture not tested but based on components: Particles may cause physical irritation to eyes. Contains no carcinogens as specified by IARC, ACGIH and NTP or OSHA. Page 2 of 3 MSDS - SpecSeal® RED Wrap Strap FOD-5018 ECOLOGICAL INFORMATION No data but not expected to be environmental hazard. DISPOSAL CONSIDERATIONS Waste Disposal: Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations. TRANSPORTATION INFORMATION DOT — not regulated. REGULATORY INFORMATION U.S. Federal Regulations TSCA Inventory Status: Article. Section 313 Supplier Notifications. This product contains no toxic chemicals subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right -To -Know Act of 1986 and of 40 CFR 372: OTHER INFORMATION NPCA-HMIS Rating Health :0 Flammability : 1 Reactivity :0 Personal Protection rating to be supplied by user depending on use conditions. STATE RIGHT -TO -KNOW LAWS No substances on the state hazardous substances list, for the states indicated below, are used in the manufacture of products on this Material Safety Data Sheet, with the exceptions indicated. While we do not specifically analyze these products, or the raw materials used in their manufacture, for substances on various state hazardous substances lists, to the best of our knowledge the products on this Material Safety Data Sheet contain no such substances except for those specifically listed below: SUBSTANCES ON THE NEW JERSEY WORKPLACE HAZARDOUS SUBSTANCE LIST PRESENT AT A CONCENTRATION OF 1% OR MORE (0.1% FOR SUBSTANCES IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): NJTSRN- SSWRED. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIATO CAUSE CANCER: None known. WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIATO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM: None known. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the data compiled. However, no representation, warranty, or guarantee is made as to its accuracy, reliability or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur form the use of this information. Responsibility for MSDS : Specified Technologies, Inc. 200 Evans Way Somerville, NJ 08876 Page 3of3 MSDS - SpecSeal® RED Wrap Strip FOD-5018