Loading...
HomeMy WebLinkAboutPERMIT Info 10 Unit Bldg 800 MacGregor Ave 200608/14/2006 15:41 9705862459 CORNERSTONE ENG PAGE 02 CONTRACTOR/ SUBCONTRACTOR TOWN BUSINESS LICENSE AFFIDAVIT Applicant Name: Black Canyon Inn Business Name; Cornerstone Eraineering ctSurveying, Inc... ,Aling Address; 1,692 Big Thompson Axe. Suite 200 .Est.es Park CO 80517 Phone Number: (970) 586-2458 Address of Project: Bldg F 800 MacGregor Ave. Estes Park CO 80517 Type of Project: Residential. Please list the required information for all contractor/subcontractor, who performed work/services for the above Plumbing & Heating Specialists Thermal concepts 2649 East Mulberry, Unit 19 Fort Collins, CO 80524 P.O. Box 1374, Lyons CO 80540 - 8262 131 Pleasant Ave. Joluistowa, CO 80534 P.O, Box 270066, Fort Collins CO 80527 1023 S. Lincoln Ave. Loveland, CO 80537 2416 Donella et 4A - Fort Collins, CO 80524 430 Olympus Road, Estes Park CO 80517 certify that this Affidavit represents a complete list of contractors/subcontractors who provided work/services on the project described above, and I understand that Final Inspection or Certificate of Occupancy will not be issued until all contractors/subcontractors listed above have acquired a current Town of Estes Park Business License/ Vjpplicant's Signature; Date: RETURN COMPLETED FORM TO: TOWN CLERK'S OFFICE, TOWN OF ESTES PARK, P,O. BOX 1200, ESTES PARK, CO 80517 Initialed By: Town Clerkl:(,,OA,„,'"") Date; c. Building Official: Xe)--/Y Date: D 8--/‘ -06 6/14/02 08/14/2006 15:41 9705862459 CORNERSTONE ENG PAGE 03 CONTRACTOR/ SUBCONTRACTOR TOWN BUSINESS LICENSE AFFIDAVIT Applicant Name: Blackn ign Business Name: Cornerstone Engineering & Surveying,_Inc, .ailing Address: 1692_Big Thompson Ave. Suite. 200 Etes Park CO 80517 Phone Number: (970) 586-2458 Address ofProject:Bldg F 800 Type ofProject: Residential Ave. Estes Par. 80517 Please list the required information for all contractor/subcontractor, who performed work/services for the above ro'ect, certify that this Affidavit represents a complete list of contractors/subcontractors who provided work/services on the project described above, and I understand that Final Inspection or Certificate of Occupancy will not be issued until all contractors/subcontractors listed above have acquired a current Town of Estes Park Business License. Applicant's Signature: Date: RETURN COMPLETED FORM TO: TOWN CLERK'S OFFICE, TOWN OF ESTES PARK, P.O. BOX 1200, ESTES PARK, CO 80517 1, ‹2 Initialed By; Town Clerk: vi Date: Building Official:)73 Date: 0876 796 6/14/02 08/14/2006 15:41 9705862459 CORNERSTONE ENG PAGE 01 CORNE I STO11E SURVEYING. INC. 1692 Big Thompson- Suite 200 Estes Park, CO 80517 970.586.2458 Phone 970.5862459 Fax TRANSMITTAL Name : cONNIE Organization: BUILDING DEPARTMENT From: JUSTIN SPROUSr Date; 8/3.4/06 Subject; CONCTRACT AFFIDAVIT Pages: Documents Transmitted: For Approval As Requested For Your Use X For Review X Hard Copy mailed For Signature Comments: Comic; here is another copy of the contractor affidavit for Black Canyon tun as you requested. in Sp use erston ngineering and Surveying rou : @Ce5 ccc.com CONTRACTOR/ SUBCONTRACTOR TOWN BUSINESS LICENSE AFFIDAVIT Applicant Name: Black Canyon Inn Business Name: Cornerstone Engineering & Surveying, Inc. Mailing Address: 1692 Big Thompson Ave. Suite 200 Estes Park CO 80517 Phone Number: (970) 586-2458 Address of Project: Bldg F 800 MacGregor Ave. Estes Park CO 80517 Type of Project: Residential Please list the required information for all contractor/subcontractor, who performed work/services for the above roiect. Business Name Contact Name Complete Address Business License # Kearney & Son's Excavating Mike Kearney P.O. Box 3623, Estes Park CO 80517 20 Phillips Carpentry Pat Phillips 2649 East Mulberry, Unit 19 Fort Collins, CO 80524 713 All Surfaces Brian Wicen P.O. Box 1374, Lyons CO 80540 - 8262 1167 Plumbing & Heating Specialists Jim Sampson 131 Pleasant Ave. Johnstown, CO 80534 1182 Thermal Concepts Mike Brown P.O. Box 270066, Fort Collins CO 80527 16 Fiske Electric Rob Denney 1023 S. Lincoln Ave. Loveland, CO 80537 239 Poudre Valley Air Craig Larson 2416 Donella Ct #A - Fort Collins, CO 80524 125 Gold Roofing Bill Goldsbury 1424 E. Eisenhower Blvd, Loveland CO 80537 559 Estes Park Painting & Decorating Roger Ping 430 Olympus Road, Estes Park CO 80517 1031 Coulson Excavating Jim Abbott 3609 N. County Rd 13, Loveland CO 80538 159 Performance Fire Protection Ray Lawson PMB #325, 453 E. Wonderview Ave Estes Park CO 80517 616 I certify that this Affidavit represents a complete list of contractors/subcontractors who provided work/services on the project described above, and I understand that Final Inspection or Certificate of Occupancy will not be issued until all contractors/subcontractors listed above have acquired a current Town of Estes Park Business License. Applicant's Signature: Date: RETURN COMPLE1ED FORM TO: TOWN CLERK'S OFFICE, TOWN OF ESTES PARK, P.O. BOX 1200, ESTES PARK, CO 80517 Initialed By: Town Clerk: Date: Building Official: Date: 6/14/02 CONTRACTOR/ SUBCONTRACTOR TOWN BUSINESS LICENSE AFFIDAVIT Applicant Name: Black Canyon Inn Business Name: Cornerstone Engineering & Surveying, Inc. Mailing Address: 1692 Big Thompson Ave. Suite 200 Estes Park CO 80517 Phone Number: (970) 586-2458 Address of Project: Bldg F 800 MacGregor Ave. Estes Park CO 80517 Type of Project: Residential Please list the required information for all contractor/subcontractor, who performed work/services for the above roiect. Business Name Contact Name Complete Address Business License # Superior Siding, LLC Randy Schmidt 6408 Orbit Way, Fort Collins, CO 80525 1019 Garrett Schafmann Construction Paul Garrett P.O. Box 2293, Estes Park, CO 80517 529 Ed's Drywall Inc. Ed Lewis P.O. Box 1686, Estes Park CO 80517 234 Colorado Rose Red Michaela Sigler P.O. Box 2116, Estes Park CO 80517 1321 Estes Park Glass Jeff Sessler P.O. Box 33, Drake, CO 80515 335 Resolution Surfaces Glen Pettet 14252 W. 44th Ave. Unit 13, Golden CO 80403 667 Garage Door Pat Street 1059-B N. Colorado Ave. Loveland, CO 80537 633 Cornerstone Concrete Bob Pavlish P.O. Box 2494, Estes Park CO 80517 153 I certify that this Affidavit represents a complete list of contractors/subcontractors who provided work/services on the project described above, and I understand that Final Inspection or Certificate of Occupancy will not be issued until all contractors/subcontractors listed above have acquired a current Town of Estes Park Business License. Applicant's Signature: Date: RETURN COMPLE'I'ED FORM TO: TOWN CLERK'S OFFICE, TOWN OF ESTES PARK, P.O. BOX 1200, ESTES PARK, CO 80517 Initialed By: Town Clerk: Date: Building Official: Date: 6/14/02 TOWN OF ESTES PARK 7f I I • 4 , DATE: —So,ne, 0,2 / .2006 Town of Estes Park Building Division 170 MacGregor Avenue Estes Park, Co. 80517 47\ Re: Foundation Setback and Elevation Certification for LOT • BLOCK — , B(&c- yoft.- otr SUBDIVISI8N; ADRESS eoo Mar-- Ore-yr Ave. ,PERMIT # 77/ 1 To Whom It May Concern Ts E. On Mo,rc,k ,,act A006 , a field crew from this office the foundation setbacks and elevations for the above -referenced lot, and found them to be in substantial Compliance with the Drainage, Final Grading and Development Plan approved by the Town of Estes Park. Sincerely, BY: seal http://www.estesnet,com (970) 586-533'1 P.O. BOX 1200 170 MAC GREGOR AVENUE ESTES PARK, CO 8051 7 FAX (970) 586-0249 Calculations And Submittals: Black Canyon Inn 10 Unit Lodge 800 McGregor Ave Estes Park, CO WIIIIM61101.uumapammMilm !VISION OFEEI 3 E SAFE 14S REVIEW PAWNED S PPROVE PPROV ED, AS C. FERECITE ATE clzifiTiitimsEm 11011011, HYDRAULIC CALCULATIONS FOR Black Canyon Inn 10 Unit Lodge Estes Park, CO -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13R DENSITY: Residential AREA OF APPLICATION: 540 sqft COVERAGE PER SPRINKLER: 320 Max sqft For Sidewall (16'x20') 400 Max sqft For Pendent (20'x20') NUMBER OF SPRINKLERS CALCULATED: 4 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 108.5 gpm TOTAL WATER REQUIRED (including hose): 108.5 gpm FLOW AND PRESSURE (@ BOR): 108.5 gpm @ 98.9 psi SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 158.0 140.0 1500.0 157.9 108.5 115.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 108.5 GPM 0.0 GPM 0.0 GPM 108.5 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 7681.0 K= 4.90 30.3 27.0 2 7681.0 K= 4.90 31.2 27.4 3 7681.0 - - - - 40.1 - - - 4 7681.0 K= 4.90 33.0 28.1 5 7677.0 K= 4.20 38.3 26.0 6 7668.0 - - - - 45.7 7 7668.0 45.7 8 7668.0 44.1 9 7668.0 45.7 10 7668.0 44.6 11 7668.0 45.8 12 7668.0 44.9 13 7668.0 45.7 14 7668.0 48.3 15 7668.0 - - 54.7 16 7666.0 a - 73.0 17 7658.0 79.2 18 7658.0 80.1 TOR 7649.0 84.9 BOR 7649.0 98.9 U1 7645.0 104.3 U2 7670.0 - - - - 93.5 SOURCE 7620.0 SOURCE 115.4 108.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn PIPE DATA PIPE TAG END ELEV. NODES (FT) Pipe: 1 1 7681.0 2 7681.0 Pipe: 2 2 7681.0 12 7668.0 Pipe: 3 3 7681.0 6 7668.0 Pipe: 4 4 7681.0 8 7668.0 Pipe: 5 5 7677.0 10 7668.0 NOZ. PT DISC. (K) (PSI) (GPM) Q(GPM) DIA(IN) LENGTH VEL(FPS) HW(C) (FT) FL/FT -27.0 1.101 4.9 30.3 27.0 9.1 150 4.9 31.2 27.4 0.118 PL FTG TL 8.00 8.00 PRESS. SUM. (PSI) PF PE PV - 54.3 1.394 PL 23.00 PF 4.9 31.2 27.4 11.4 150 FTG 5ET PE 0.0 44.9 0.0 0.137 TL 59.00 PV 0.0 1.101 PL 16.50 PF 0.0 40.1 0.0 0.0 150 FTG 3ET PE 0.0 45.7 0.0 0.000 TL 37.50 PV -28.1 1.101 PL 22.00 PF 4.9 33.0 28.1 9.5 150 FTG 3ET PE 0.0 44.1 0.0 0.128 TL 43.00 PV - 26.0 1.101 PL 10.25 PF 4.2 38.3 26.0 8.8 150 FTG ET PE 0.0 44.6 0.0 0.111 TL 21.25 PV Pipe: 6 6 7668.0 0.0 7 7668.0 0.0 Pipe: 7 8 7668.0 9 7668.0 Pipe: 7A 10 7668.0 11 7668.0 Pipe: 8 12 7668.0 13 7668.0 Pipe: 9 13 7668.0 14 7668.0 Pipe: 10 7 7668.0 9 7668.0 Pipe: 11 9 7668.0 11 7668.0 Pipe: 11A 11 7668.0 14 7668.0 0.0 1.101 PL 10.25 PF 45.7 0.0 0.0 150 FTG T PE 45.7 0.0 0.000 TL 16.25 PV - 28.1 1.101 PL 6.90 PF 0.0 44.1 0.0 9.5 150 FTG T PE 0.0 45.7 0.0 0.128 TL 12.90 PV - 26.0 1.101 PL 5.00 PF 0.0 44.6 0.0 8.8 150 FTG T PE 0.0 45.8 0.0 0.111 TL 11.00 PV -54.3 1.394 PL 5.50 PF 0.0 44.9 0.0 11.4 150 FTG ---- PE 0.0 45.7 0.0 0.137 TL 5.50 PV - 54.3 1.394 PL 13.12 PF 0.0 45.7 0.0 11.4 150 FTG T PE 0.0 48.3 0.0 0.137 TL 19.12 PV 0.0 1.394 PL 7.90 PF 0.0 45.7 0.0 0.0 150 FTG ---- PE 0.0 45.7 0.0 0.000 TL 7.90 PV -28.1 1.394 PL 1.00 PF 0.0 45.7 0.0 5.9 150 FTG ---- PE 0.0 45.8 0.0 0.041 TL 1.00 PV - 54.1 1.394 PL 12.33 PF 0.0 45.8 0.0 11.4 150 FTG T PE 0.0 48.3 0.0 0.136 TL 18.33 PV 0.9 0.0 0.6 8.1 5.6 0.9 0.0 5.6 0.0 5.5 5.6 0.6 2.3 3.9 0.5 0.0 0.0 0.0 1.6 0.0 0.6 1.2 0.0 0.5 0.8 0.0 0.9 2.6 0.0 0.9 0.0 0.0 0.0 0.0 0.0 0.2 2.5 0.0 0.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 • DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn PIPE TAG END ELEV. NOZ. PT DISC. NODES (FT) (K) (PSI) (GPM) Pipe: 12 14 7668.0 0.0 48.3 15 7668.0 0.0 54.7 Pipe: 13 15 7668.0 0.0 54.7 16 7666.0 0.0 73.0 Pipe: 13A 16 7666.0 0.0 17 7658.0 0.0 Pipe: 14 17 7658.0 18 7658.0 Q(GPM) DIA(IN) LENGTH VEL(FPS) HW(C) (FT) FL/FT - 108.5 1.394 0.0 22.8 150 0.0 0.492 - 108.5 0.0 22.8 0.0 PL 7.00 FTG E TL 13.00 PRESS. SUM. (PSI) PF PE PV 6.4 0.0 3.5 1.394 PL 17.50 PF 17.5 150 FTG 2ET PE 0.9 0.492 TL 35.50 PV 3.5 - 108.5 2.003 PL 13.50 PF 73.0 0.0 11.0 150 FTG ET PE 79.2 0.0 0.084 TL 32.50 PV 0.0 79.2 0.0 80.1 Pipe: 15 18 7658.0 0.0 80.1 TOR 7649.0 0.0 84.9 Pipe: 16 BOR 7649.0 TOR 7649.0 Pipe: 17 BOR 7649.0 U1 7645.0 Pipe: 18 U1 7645.0 U2 7670.0 - 108.5 2.003 PL 2.00 PF 0.0 11.0 150 FTG E PE 0.0 0.084 TL 11.00 PV - 108.5 0.0 11.0 0.0 2.003 PL 9.00 PF 150 FTG G PE 0.084 TL 10.51 PV FIXED PRESSURE LOSS DEVICE 0.0 98.9 0.0 14.0 psi, 108.5 gpm 0.0 84.9 0.0 0.0 98.9 0.0 104.3 0.0 104.3 0.0 93.5 - 108.5 0.0 11.1 0.0 2.000 PL 25.00 PF 140 FTG 2EG PE 0.096 TL 37.46 PV 2.7 3.5 0.8 0.9 0.0 0.8 0.9 3.9 0.8 3.6 1.7 0.8 -108.5 8.390 PL 425.00 PF 0.1 0.0 0.6 140 FTG 5E PE -10.8 0.0 0.000 TL 580.00 PV 0.0 Pipe: 19 -108.5 6.280 PL 600.00 PF 0.3 U2 7670.0 0.0 93.5 0.0 1.1 140 FTG 4E PE 21.7 SOURCE 7620.0 SRCE 115.4 (N/A) 0.000 TL 696.00 PV 0.0 NOTES: (1) Calculations were performed by the HASS 7.3 under license no. 49011032 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 computer program (2) The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.101 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 22.8 ft/sec at pipe 13. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * Diameter (in) 2.067 PAGE: D Diameter (in) 6.280 8.390 PAGE: P Diameter (in) 1.101 1.394 2.003 MATERIAL: S40 HWC: 120 Equivalent Fitting Lengths in Feet E T L C B G A Ell Tee LngEll ChkVly BfyVly GatVly AlmChk 5.00 10.00 3.00 11.00 6.00 1.00 10.00 MATERIAL: DIRON HWC: 140 Equivalent Fitting E T L C E11 Tee LngEll ChkV1v 24.00 52.00 16.00 55.00 31.00 60.00 22.00 78.00 MATERIAL: CPVC HWC: 150 Equivalent Fitting E T L G Ell Tee LngEll GatVly 5.00 6.00 0.00 1.51 6.00 6.00 0.00 1.51 9.00 10.00 0.00 1.51 Lengths in Feet B G N BfyVly GatVly NPTee 17.00 5.00 52.00 21.00 7.00 60.00 Lengths in Feet C B ChkVly BtyV1v 7.55 9.06 10.57 9.06 16.61 9.06 D DPV1v 10.00 N NPTee 10.00 ° D���z 4/I8/20O6C �\208gBI0KLER SYSTEM HYDRAULIC ANALYSIS gage 5 06 CALCG\BIACK CANYON INN\BIACK CANYON I00 SIDOWALL m PENDENTSDF JOB TITLE: Black Canyon Inn ' WATER SUPPLY ANALYSIS 0,0 -14,7 , - - - - _ _ I � = 2 I I | I . ! I I I 400600 800 1000 1200 I400 1600 l800 2000 FLOW (GPM) LEGEND Available pressure 157'86 psi @ I08'5 gpm � Required pressure II5'40 psi @ I08'5 gpm HYDRAULIC CALCULATIONS FOR Black Canyon Inn 10 Unit Lodge Estes Park, CO -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13R DENSITY: Residential AREA OF APPLICATION: 540 sqft COVERAGE PER SPRINKLER: 320 Max sqft For Sidewall (16'x20') 400 Max sqft For Pendent (20'x20') NUMBER OF SPRINKLERS CALCULATED: 4 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 86.1 gpm TOTAL WATER REQUIRED (including hose): 86.1 gpm FLOW AND PRESSURE (0 BOR): 86.1 gpm @ 72.6 psi SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 158.0 140.0 1500.0 157.9 86.1 87.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 86.1 GPM 0.0 GPM 0.0 GPM 86.1 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 7681.0 K= 4.90 18.4 21.0 2 7681.0 K= 4.90 19.0 21.3 3 7681.0 K= 4.90 19.9 21.9 4 7681.0 K= 4.90 19.9 21.9 5 7677.0 - - - - 26.2 6 7668.0 28.5 7 7668.0 29.8 8 7668.0 29.0 9 7668.0 30.0 10 7668.0 30.1 11 7668.0 30.1 12 7668.0 29.7 13 7668.0 30.2 14 7668.0 31.8 15 7668.0 36.0 16 7666.0 98.2 17 7658.0 53.5 18 7658.0 - 54.1 TOR 7649.0 - - _ 58.6 BOR 7649.0 72.6 Ul 7645.0 76.7 U2 7670.0 - - - - 65.9 SOURCE 7620.0 SOURCE 87.7 86.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn PIPE DATA PIPE TAG END NODES ELEV. (FT) Pipe: 1 1 7681.0 2 7681.0 Pipe: 2 2 7681.0 12 7668.0 NOZ. PT DISC. (K) (PSI) (GPM) Q(GPM) DIA(IN) LENGTH VEL(FPS) HW(C) (FT) FL/FT - 21.0 4.9 18.4 21.0 7.1 4.9 19.0 21.3 4.9 19.0 0.0 29.7 1.101 PL 150 FTG 0.074 TL 8.00 8.00 PRESS. SUM. (PSI) PF PE PV - 42.3 1.394 PL 23.00 PF 21.3 8.9 150 FTG 5ET PE 0.0 0.086 TL 59.00 PV Pipe: 3 -21.9 3 7681.0 4.9 19.9 21.9 7.4 6 7668.0 0.0 28.5 0.0 Pipe: 4 -21.9 4 7681.0 4.9 19.9 21.9 7.4 8 7668.0 0.0 29.0 0.0 Pipe: 5 5 7677.0 0.0 26.2 10 7668.0 0.0 30.1 Pipe: 6 6 7668.0 0.0 28.5 7 7668.0 0.0 29.8 Pipe: 7 8 7668.0 9 7668.0 0.0 29.0 0.0 30.0 Pipe: 7A 10 7668.0 0.0 30.1 11 7668.0 0.0 30.1 Pipe: 8 12 7668.0 13 7668.0 1.101 PL 16.50 PF 150 FTG 3ET PE 0.080 TL 37.50 PV 1.101 PL 22.00 PF 150 FTG 3ET PE 0.080 TL 43.00 PV 0.0 1.101 PL 10.25 PF 0.0 0.0 150 FTG ET PE 0.0 0.000 TL 21.25 PV - 21.9 1.101 PL 10.25 PF 0.0 7.4 150 FTG T PE 0.0 0.080 TL 16.25 PV -21.9 1.101 PL 6.90 PF 0.0 7.4 150 FTG T PE 0.0 0.080 TL 12.90 PV 0.0 1.101 PL 5.00 PF 0.0 0.0 150 FTG T PE 0.0 0.000 TL 11.00 PV - 42.3 1.394 PL 5.50 PF 0.0 29.7 0.0 8.9 150 FTG ---- PE 0.0 30.2 0.0 0.086 TL 5.50 PV Pipe: 9 13 7668.0 0.0 14 7668.0 0.0 Pipe: 10 7 7668.0 9 7668.0 Pipe: 11 9 7668.0 11 7668.0 Pipe: 11A 11 7668.0 14 7668.0 - 42.3 1.394 PL 13.12 PF 30.2 0.0 8.9 150 FTG T PE 31.8 0.0 0.086 TL 19.12 PV - 21.9 0.0 29.8 0.0 4.6 0.0 30.0 0.0 1.394 PL 7.90 PF 150 FTG ---- PE 0.025 TL 7.90 PV - 43.7 1.394 PL 1.00 PF 0.0 30.0 0.0 9.2 150 FTG ---- PE 0.0 30.1 0.0 0.092 TL 1.00 PV - 43.7 1.394 PL 12.33 PF 0.0 30.1 0.0 9.2 150 FTG T PE 0.0 31.8 0.0 0.092 TL 18.33 PV 0.6 0.0 0.3 5.1 5.6 0.5 3.0 5.6 0.4 3.5 5.6 0.4 0.0 3.9 0.0 1.3 0.0 0.4 1.0 0.0 0.4 0.0 0.0 0.0 0.5 0.0 0.5 1.7 0.0 0.5 0.2 0.0 0.1 0.1 0.0 0.6 1.7 0.0 0.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 -86.1 1.394 PL 7.00 PF 4.2 14 7668.0 0.0 31.8 0.0 18.1 150 FTG E PE 0.0 15 7668.0 0.0 36.0 0.0 0.321 TL 13.00 PV 2.2 Pipe: 13 -86.1 1.394 PL 17.50 PF 11.4 15 7668.0 0.0 36.0 0.0 18.1 150 FTG 2ET PE 0.9 16 7666.0 0.0 48.2 0.0 0.321 TL 35.50 PV 2.2 Pipe: 13A -86.1 2.003 PL 13.50 PF 1.8 16 7666.0 0.0 48.2 0.0 8.8 150 FTG ET PE 3.5 17 7658.0 0.0 53.5 0.0 0.055 TL 32.50 PV 0.5 Pipe: 14 -86.1 2.003 PL 2.00 PF 0.6 17 7658.0 0.0 53.5 0.0 8.8 150 FTG E PE 0.0 18 7658.0 0.0 54.1 0.0 0.055 TL 11.00 PV 0.5 Pipe: 15 -86.1 2.003 PL 9.00 PF 0.6 18 7658.0 0.0 54.1 0.0 8.8 150 FTG G PE 3.9 TOR 7649.0 0.0 58.6 0.0 0.055 TL 10.51 PV 0.5 Pipe: 16 FIXED PRESSURE LOSS DEVICE BOR 7649.0 0.0 72.6 0.0 14.0 psi, 86.1 gpm TOR 7649.0 0.0 58.6 0.0 Pipe: 17 -86.1 2.000 PL 25.00 PF 2.4 BOR 7649.0 0.0 72.6 0.0 8.8 140 FTG 2EG PE 1.7 U1 7645.0 0.0 76.7 0.0 0.063 TL 37.46 PV 0.5 Pipe: 18 -86.1 8.390 PL 425.00 PF 0.0 U1 7645.0 0.0 76.7 0.0 0.5 140 FTG 5E PE -10.8 U2 7670.0 0.0 65.9 0.0 0.000 TL 580.00 PV 0.0 Pipe: 19 -86.1 6.280 PL 600.00 PF 0.2 U2 7670.0 0.0 65.9 0.0 0.9 140 FTG 4E PE 21.7 SOURCE 7620.0 SRCE 87.7 (N/A) 0.000 TL 696.00 PV 0.0 NOTES: (1) Calculations were performed by the HASS 7.3 computer program under license no. 49011032 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.092 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 18.1 ft/sec at pipe 12. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * Diameter (in) MATERIAL: S40 HWC: 120 Equivalent Fitting E T L C Ell Tee LngEll ChkVly 2.067 5.00 10.00 3.00 11.00 PAGE: D Diameter (in) MATERIAL: DIRON HWC: 140 Equivalent Fitting E T L C Ell Tee LngEll ChkVly 6.280 24.00 52.00 16.00 55.00 8.390 31.00 60.00 22.00 78.00 PAGE: P Diameter (in) 1.101 1.394 2.003 MATERIAL: CPVC HWC: 150 Equivalent Fitting E T L G Ell Tee LngEll GatVly 5.00 6.00 0.00 1.51 6.00 6.00 0.00 1.51 9.00 10.00 0.00 1.51 Lengths in Feet B G A BfyVly GatVly AlmChk 6.00 1.00 10.00 Lengths in Feet B G N BfyVly GatVly NPTee 17.00 5.00 52.00 21.00 7.00 60.00 Lengths in Feet C B ChkVly BtyVly 7.55 9.06 10.57 9.06 16.61 9.06 D DPV1v 10.00 N NPTee 10.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/18/2006C:\2006 CALCS\BLACK CANYON INN\BLACK CANYON INN SIDEWALL & PENDENT.SDF JOB TITLE: Black Canyon Inn WATER SUPPLY ANALYSIS 160.1 140.0 G120.0 A U G E100.0 P 2 R 3 E 80.0 S S U R 60.0 E ( p 40.0 s i 20.0 Static: 158.00 psi Resid: 140.00 psi Flow: 1500.0 gpm 4 1 1 2 0.0 -14.7 I I I I I I 1 1 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) LEGEND Available pressure 157.91 psi @ 86.1 gpm 1 Required pressure 87.69 psi @ 86.1 gpm 'NCO/Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB — Z8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at - IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner Is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - TY1231 - TY2131 - TY2231 - TY3131 - Upright 2.8K, 1/2"NPT Pendent 2.8K, 1/2"NPT Upright 4.2K, 1/2"NPT Pendent 4.2K, 1/2"NPT Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.0K, 3/4"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/barli2) K = 4.2 GPM/psili2 (60,5 LPM/barli2) K = 5.6 GPM/psis/2 (80,6 LPM/barli2) K = 8.0 GPM/psin2 (115,2 LPM/barl/2) Temperature Ratings Refer to Table A and B Page 1 of 8 JULY, 2004 TFP171 Page 2 of 8 TFP171 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING ** NOMINAL SURFACE 1/2 MAKE -IN NPT 2-1/4" (57,2 mm) 1 1-9/16" (39,7 mm) SSP DEFLECTOR * PENDENT 1 - Frame 3 - Sealing 2 - Button Assembly STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS 2-7/8" (73,0 mm) DIA. --,-] SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) 1/2" NPT** f + RECESSED PENDENT UPRIGHT CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 4 - Bulb 5 - Compression Screw 6 - Deflector 7 - Bushing ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING ** NOMINAL SURFACE 1/2" MAKE -IN NPT 1 2-3/16" (55,6 mm) SSP DEFLECTOR * PENDENT 1-Frame 2-Button STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS 2-7/8" (73,0 mm) DIA, --4' SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN i l 1/2" NPT ** RECESSED PENDENT UPRIGHT 3 - Sealing 4 - Bulb Assembly 5 - Compression Screw 6 - Deflector 1 2-3/16" (55,6 mm) CROSS SECTION * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame Bronze Button Brass/Copper Sealing Assembly Beryllium Nickel w/Teflont Glass Compression Screw Bronze Deflector ....... Copper/Bronze Bushing (K=2.8) Bronze Bulb Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. t DuPont Registered Trademark 1/2" (12,7 mm) 3/4" ** NOMINAL NPT MAKE -IN TFP171 Page 3 of 8 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2" ** NOMINAL SURFACE NPT MAKE -IN 2-3/16° (55,6 mm) I 1-1/2' (38,1 mm) SSP DEFLECTOR* 1 - Frame 2-Button STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS 2-7/8" (73,0 mm) DIA. --•--1 PENDENT RECESSED PENDENT 3 - Sealing 4 - Bulb 6 - Deflector Assembly 5 - Compression Screw SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 1/2" NPT** UPRIGHT CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. 2-3/16" (55,6 mm) * t QUICK RESPONSE SERIES TY-FRB UPRIFIGURE 3 GHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR * PENDENT 1 - Frame 3 = Sealing 2 - Button Assembly STYLE 30 or 40 RECESSED ESCUTCHEON Vir -"-- 2-7/8" (73,0 mm) DIA. RECESSED PENDENT WRENCH F LATS FLATS 4 - Bulb 5 - Compression Screw 6 Deflector SSU* DEFLECTOR 1/2" (12,7 mm) NOMINAL MAKE -IN 2- /4° (57,2 mm) 3/4" NPT** UPRIGHT CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY431) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT * Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler Page 4 of 8 SPRINKLER FINISH (See CHROME I PLATED 1, 2, 3, 5 Note 7) WHITE"" (POLYESTER K TYPE TEMP. BULB LIQUID NATURAL BRASS 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 155"F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY1231)* 175°F/79°C Yellow Figure 5 200°F/93°C Green 1, 2, 5 135"F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 6 200°F/93°C Green 135°F/57°C Orange P(n2231; 155°F/68°C Red and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 4.2 (TY2131) 1/2" 286°F/141°C Blue 1,2 135°F/57°C Orange NPT RECESSED PENDENT 155°F/68°C Red (TY2231)* 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)" 175°F/79°C Yellow Figure 8 200°F/93°C Green NOTES 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "" Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm), A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 TFP171 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over -tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED WHITE* POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3 31) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 1,2,3,4,5,6,7 175°F/79°C Yellow 200°F/93°C Green 286F/141°C Blue RECESSED PENDENT (TY3231)* Figure 9 135°F/57°C Orange 1, 2, 4, S N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY3231p• Figure 10 135°F/57°C Orange 1, 2, 3, 4, 5 1, 2, 4, 5 N/A 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 8.0UPR NPT PENDENT (TY4231) and 4131) (TY3/4" 135F/57°C Orange 1,2,3,4,5,6,7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)* Figure 11 135°F/57°C Green 1, 2, 4, 5 N/A 155°F/68°C Orange 175°F/79°C Red 200F/93°C Yellow RECESSED PENDENT 135°F/57°C Orange 1, 2, 3, 4, 5 N/A 155F/68°C Red (TY4231)** Figure 12 175°F/79°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53,428•3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable, "' Frame and Deflector only. Listings and approvals apply to color (Special Order).. N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4' DIA. (57,2 mm) MOUNTING SURFACE CLOSURE 3/4" (19,1 mm) 1/4' (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB 1-5/16" (33,3 mm) 13/16° (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 5/8±1/4" (15,91-6,4 mm) FACE OF SPRINKLER FITTING 2-7/8' DIA. (73,0 mm) 2-1/4' DIA., (57,2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES TY-FRB 1-1/4' (31,8 mm) 3/4"(19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is TFP171 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY-FRB 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com• pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFP171 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm) MOUNTING SURFACE CLOSURE II lir Rir lflf 1 SERIES TY-FRB 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1_ 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm) MOUNTING SURFACE 3/4" (19,1 mm) 1/4' (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) CLOSURE SERIES TY-FRB 1-5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with Page 7 of 8 1/2t1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8° (3,2 mm) SERIES TY-FRB 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 1/2t1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING \ MOUNTING SURFACE 2-7/8' DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) CLOSURE SERIES TY-FRB 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-5/16' (33,3 mm) 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A' USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH ocal requirements and/or national codes. WRENCH RECESS f\f PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 P/N 57 - XXX - X - XXX I I MODEUSIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 SPRINKLER 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED TFP171 TEMPERATURE RATING 135 135F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C * Eastem Hemisphere sales only.. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL DRIER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS. R. FOR A PARTICULAJR- Ordering Procedure 0tsatteakvon tecaI distributor for avail- abtlimindicale the fulrproduct name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated . , .. While Coated ....... White RAL9010" Brass Plated P/N 56-701-9-010 P/N 56-701.4.010 P/N 56-701-3-010 P/N 56-701.2M010 1/2" (15 mm) Style 20 Chrome Plated P/N 56-705-9-010 White Coated P/N 56-705-4-010 White RAL9010• P/N 56-705-3-010 Brass Plated P/N 56-705-2-010 3/4' (20 mm) Style 30 Chrome Plated P/N 56-705-9-011 White Coated P/N 56-705-4-011 White RAL9010" P/N 56-705.3 011 Brass Plated P/N 56-705-2-011 3/4" (20 mm) Style 40 Chrome Plated P/N 56-700-9-010 White Coated P/N 56-700-4-010 White RAL9010' P/N 56-700-3.010 Brass Plated P/N 56-700-2.010 " Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 two IFire & Bui/ding Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 la rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description The Series LFII (TY2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprin- klers designed for use in residential occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII (TY2234) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2234) has a 4.9 (70,6) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY2234) is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceil- ing position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY2234) Residential Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY2234 Page 1 of 8 JANUARY, 2006 TFP400 Page 2 of 8 TFP400 Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Minimum Flow (b) and Residual Pressure For Horizontal Ceiling (Max. 2 Inch Rise for 12 Inch Run) Minimum Flow lb) and Residual Pressure For Sloped Ceiling (Greater Than 2 Inch Rise Up To Max. 4 Inch Rise for 12 Inch Run) Minimum Flow (b) and Residual Pressure For Sloped Ceiling (Greater Than 4 Inch Rise Up To Max. 8 Inch Rise for 12 Inch Run) 155°F/68°C or 175°F/79°C 155°F/68°C 175°F/79°C 155F/68°C 175°F/79°C 12 x 12 (3,7 x 3,7) 12 (3,7) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 18 x 18 (5,5 x 5,5) 18 (5,5) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 20 x 20 (6,1 x 6,1) 20 (6,1) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 21 GPM (79,5 LPM) 18.4 psi (1,27 bar) 22 GPM (83,3 LPM) 20.2 psi (1,39 bar) (a) For coverage area dimensions less than o between those indicated, it is necessary to use the minimum required highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS flow for the next are calculated (TY2234) Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature Rating: 155FI68°C or 175°F/79°C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame Brass Button Bronze Sealing Assembly . Beryllium Nickel w/Teflont Bulb 3 mm dia. Glass Compression Screw .....Bronze Deflector Bronze Ejection Spring ... . Stainless Steel tDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority having Juris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. • For "Horizontal Ceilings" (maximum 2 inch rise for 12 inch run), the sprin- klers are to be installed with a deflec- tor to ceiling distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTES The Beam Ceiling Design Criteria" section starting on Page 4 permits de- flector to ceiling distances up to 15-3/4 inches. So as to help avoid obstructions to water distribution, a maximum 12 inch deflector -to -ceiling distance is permit- ted forNFPA 13D and NFPA 13R appli- cations where the sprinklers are located in closets. • For "Sloped Ceilings" (greater than 2 inch rise up to 8 inch rise for 12 inch run), the sprinklers are to be installed with a deflector to ceiling TFP400 Page 3 of 8 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * * Temperature rating is indicated on Deflector. 7/16" (11,1 mm) 1/2" ESCUTCHEON NOMINAL NPT PLATE SEATING MAKE -IN SURFACE CROSS SECTION PENDENT 2-1/4" (57,2 mm) 1-5/8" (41,3 mm) 2-7/8" DIA. (73,0 mm) STYLE 20 RECESSED ESCUTCHEON RECESSED PENDENT FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) CLOSURE TY2234 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2234) RESIDENTIAL PENDENT SPRINKLER distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2 Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft.. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). WRENCH RECESS (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 4 of 8 Beam Ceiling Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in residential oc- cupancies with horizontal ceilings (Le., slopes up to a 2 inch rise over a 12 inch run) with beams when installed in ac- cordance with the following criteria: General Information. The basic con- cept of this protection scheme is to locate the sprinklers on the underside of the beams, Ref. Figure 5, (not in the beam pockets); to identify the main beams that principally run in one direc- tion as "primary beams"; and, to iden- tify the beams that run principally per- pendicular to the main beams, as may be present (or in some cases may be necessary for proper sprinkler protec- tion), as "secondary beams". Primary and Secondary Beam Types. Solid surface, solid or hollow core, combustible or non-combustible. Primary and Secondary Beam Posi- tioning. Directly attached to the un- derside of a combustible or non-com- bustible smooth ceiling at any elevation. Primary Beam Cross -Section: Maxi- mum depth of 14 inches and the maxi- mum width is unlimited. The cross - sectional shape of the primary beam may be rectangular to circular. Secondary Beam Cross -Section. Maximum depth to be no greater than the primary beam and the maximum width is unlimited. The cross -sectional shape of the secondary beam may be rectangular to circular. Primary Beam Spacing. The primary beams (Fig. 6A) are to be 3 ft. - 4 in. to 6 ft. from the compartment wall to cen- ter of the nearest beam and from cen- ter to center between beams. Secondary Beam Spacing. The sec- ondary beams principally run perpen- dicular to the primary beams. Secondary beams of a depth equal to the primary beam must be placed so that the beam pockets created by the primary beams do not exceed 20 feet in length (Fig. 6B). NOTE When the beam pockets created by the primary beams exceed 20 feet in length, the installation will require the use of secondary beams as described above. Otherwise, secondary beams need not be present. Secondary beams of a cross -sectional depth greater than one -quarter the depth of the primary beams are to be a minimum of 3 ft. - 4 in. from the compartment wall to center of the nearest beam and from center to cen- ter between beams (Fig. 6C). Secondary beams of a cross -sectional depth no greater than one -quarter the depth of the primary beams may be placed at any compartment wall to center of the nearest beam distance and from any center to center distance between beams (Fig. 6C). Lintels. Lintels over doorways exiting the compartment must be present. The minimum height for the lintels is 8 inches or no less than the depth of the Primary Beams, whichever is greater. Sprinkler Types. Series LFII (TY2234), 155F and 175F, Pendent and Recessed Pendent Residential Sprinklers. Sprinkler Coverage Area and Hy- draulic Design. The sprinkler cover- age areas and hydraulic design criteria as presented in the Table A for "Hori- zontal Ceilings" are to be applied. Sprinkler Position. The deflector to bottom of primary beams for the Series LFII (TY2234) Pendent Sprinklers or Series LFII (TY2234) Recessed Pen- dent Sprinklers is to be 1-1/4 to 1-3/4 inches (Fig. 5A). The vertical center- line of the Series LFII (TY2234) Pen- dent Sprinklers is to be no greater than half the primary beam cross -sectional width plus 2 inches from the centerline of the primary beam (Fig 5B). NOTES Core drilling of beams to allow the in- stallation of sprinkler drops requires consulting with a structural engineer. Where core drilling is not permitted, the previously stated sprinkler position criteria for the Series LFII (TY2234) Pendent Sprinklers allows for the sprinkler drop to be placed adjacent to the primary beam. Beam and Soffit Arrangements. A soffit is permitted to be placed around the perimeter of a compartment with the beam arrangement within the sof- fited area (Fig.7). The cross-section of the soffit may be any size as long as it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. When soffits are present, the pre- viously provided 3 ft. - 4 in, to 6 ft. "compartment wall to adjacent beam" distance for the primary and secon- dary beams is to be measured from the face of the soffit as opposed to the compartment wall. TFP400 B Eg z E E m MAXIMUM ONE-HALF BEAM WIDTH PLUS 2" (50,8 mm) TY2234 TY2234 FIGURE 5 SPRINKLER POSITIONING UNDER PRIMARY BEAMS (Refer to the "Beam Ceiling Design Criteria" section) NOTE Although the distance to the beams is measured from the face of the soffit, the sprinkler coverage area is to be measured from the compartment wall. *REFER TO FIGURE 68 COMPARTMEN FOR SPANS WALLS EXCEEDING 20'-0" (6,1 m) TFP400 Page 5 of 8 ALL FIGURES: DISTANCES ARE MEASURED TO COMPARTMENT WALL FACES AND TO CENTERL OF BEAMS A AA 14" (356 mm) MAXIMUM INES /SA FPRIMARY BEAM COMPARTMENTWALLS wm=m)iNsm)mi O FIGURE 6A PRIMARY BEAM SPANS UP TO 20'-0" (6,1 m) R A=3'-4"to6'-0"(1,0to1,8m) PRIMARY BEAMS HAV- ING A 14" (356 mm) MAXIMUM DEPTH 20'-0" (6,1 m) MAXIMUM ATq�q--.1 SECONDARY BEAM PRIMARY BEAM COMPARTMENT WALLS FIGURE 6B PRIMARY BEAM SPANS GREATER THAN 20'-0" (6,1 m) A = 3'-4" to 6'-0" (1,0 to 1,8 m) FOR PRIMARY BEAMS HAV- INGA 14" (356 mm) MAXIMUM DEPTH B = 20'-0" (6,1 m) MAXIMUM FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN DEPTH TO PRIMARY BEAMS AND THAT MUST BE IN PLACE SO THAT PRIMARY BEAM POCKETS DO NOT EXCEED 20'-0" (6,1 m) A A A--.1 T SECONDARY -1_1_1111K BEAM 114W—k\t\NI\Tilk PRIMARY* —, BEAM FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS A = 3'-0" to 6'-0" (1,0 to 1,8 m) FOR PRIMARY BEAMS HAV- ING A 14" (356 mm) MAXIMUM DEPTH C = 3'-4" (1,0 m) MINIMUM FOR SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25% OF PRIMARY BEAMS — or— C = ANY DISTANCE FOR SEC ONDARY BEAMS HAVING DEPTHS UP TO 25% OF PRIMARY BEAMS FIGURE 6 BEAM ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) Page 6 of 8 TFP400 SECONDARY BEAM PRIMARY BEAM FACE OF SOFFIT * USE DISTANCES SHOWN IN FIGURES 6A, 6B 8 6C, EXCEPT MEASUREMENTS ARE TAKEN FROM FACES OF SOFFITS INSTEAD OF FROM COMPARTMENT WALL SURFACES COMPARTMENT WALLS FIGURE 7 BEAM AND SOFFIT ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) Installation The Series LFII (TY2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Pendent Sprinklers must be installed in accordance with the following instructions, Step 1. Pendent sprinklers are to be installed in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref, Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats, The Series LFII Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Recessed pendent sprinklers are to be installed in the pendent posi- tion with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series LFII (TY2234) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- TFP400 age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder.. Page 7 of 8 Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (TY2234), K=4.9, Residen- tial Pendent Sprinkler with (specify) temperature rating and (specify) fin- ish, P/N (specify). 155°F/68°C or Chrome Plated P/N 51-201-9-155 155°F/68°C White Polyester P/N 51-201-4-155 155°F/68°C White (RAL9010)* P/N 51-201-3-155 155°F/68°C Natural Brass P/N 51-201-1-155 175°F/79°C or Chrome Plated P/N 51-201-9-175 175°F/79°C White Polyester P/N 51-201-4-175 175°F/79°C White (RAL9010)• P/N 51-201-3-175 175°F/79°C Natural Brass P/N 51-201-1-175 `Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (spec- ify'). *Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 8 of 8 TFP400 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqcci I Fire &Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 ist rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII (TY1334) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY1334) has a 4.2 (60,5) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY1334) is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- vides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjust- ment provided by the Recessed Es- cutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY1334) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner Is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY1334 oh 11111111 Page 1 of 8 JANUARY, 2006 TFP410 Page 2 of 8 TFP41O Components: 1 - Frame 2 - Button Assembly 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* TOP -OF - DEFLECTOR * Temperature rating is indicated on top of Deflector. 7/ 6" (11,1 mm) END -OF - DEFLECTOR BOSS * APWRIi 1..:C841113.11111111111111 1 11IIIIIIIIIIIM 1-5/8" 7/16" (11,1 mm) NOMINAL MAKE -IN CENTERLINE OF WATERWAY 1/2" NPT (41,3 mm) ESCUTCHEON 2-1/4" PLATE SEATING (57,2 mm) SURFACE WRENCH FLATS STYLE 20 RECESSED ESCUTCHEON RECESSED FIGURE 1 SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE TOP -OF- CLOSURE DEFLECTOR \ MOUNTING PLATE END -OF - DEFLECTOR BOSS 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) 7/16t1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING 2.7/8 DIA. (73,0 mm) 2-1/4 DIA. (57,2 mm) 1/8" (3,2 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER WRENCH RECESS (END "A" USED FOR TY1334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP41O Page 3 of 8 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psi1/2 (60,5 LPM/bars/2) Temperature Rating: 155°F/68°C or 175°F/79°C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame Brass Button Bronze Sealing Assembly Beryllium Nickel w/Teflont Bulb 3 mm dia. Glass Compression Screw Bronze Deflector ... Copper tDupont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority Having Ju- risdiction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A, B, C, and D as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A, B, C, and D for NFPA 13D and 13R as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with an end -of - deflector -boss to wall distance of 1- 3/8 to 6 inches or in the recessed po- sition using only the Style 20 Re- cessed Escutcheon as shown in Figure 2. In addition the top -of -deflector -to -ceil- ing distance is to be within the range (Ref. Table A, B, C, or D) being hy- draulically calculated. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The Series LFII (TY1334) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Horizontal Sidewall Sprinklers must be installed in ac- cordance with the following instruc- tions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling with the front edge of the De- flector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following in- structions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. (Continued on Page 8) Page 4 of 8 TFP41O ELEVATION Maximum Coverage Area (a) Width x Length (b) Ft. x Ft. (m x m) 12 x 12 Maximum Spacing Ft. (m) Minimum Flow (c) and Residual Pressure Top -Of -Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top -Of -Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) 155F/68°C 175°F/79°C 155°F/68°C 175F/79°C (3,7 x 3,7) 14 x 14 (4,3 x 4,3) 16 x 16 (4,9 x 4,9) 16 x 18 (4,9 x 5,5) 16x20 (4,9 x 6,1) 12 (3,7) 14 (4,3) 16 (4,9) 16 (4,9) 16 (4,9) 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) 13 GPM (49,2 LPM) 9.6 psi (0,66 bar) 17 GPM (64,3 LPM) 16.4 psi (1,13 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) 13 GPM (49,2 LPM) 9.6 psi (0,66 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. (d) Sidewall sprinklers, where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch run to a slope up to 2 inch rise for 12 inch run, must be located per one of the following: • Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. • Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR SERIES RESIDENTIAL HORIZONTAL SIDEWALLHE AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR HORIZONTAL CEILING (Maximum 2 Inch Rise for 12 Inch Run) TFP41O Page 5 of 8 12" 8" MAXIMUM ELEVATION Maximum Coverage Area la) Width x Length lb) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Minimum Flow (o) and Residual Pressure (I) Two sprinkler design with the sprinklers at the high point of the slope and positioned to discharge down the slope. Top -Of -Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top -Of -Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 12 x 12 (3,7 x 3,7) 12 (3,7) 1 12 GPM (45,4 LPM) 8.2 psi(0,57 bar) 1 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) 1 13 GPM (49,2 LPM) 9.6 psi (0,66 bar) 1 13 GPM (49,2 LPM) 9.6 psi (0,66 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) 1 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) 1 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) 1 17 GPM (64.3 LPM) 16.4 psi (1,13 bar) 1 17 GPM (64.3 LPM) 16.4 psi (1,13 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) 1 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) I 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 1 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) I 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 16 x 18 (4,9 x 5,5) 16 (4,9) 1 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 1 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 1 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 1 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 16 x 20 (4,9 x 6,1) 16 (4,9) I 24 GPM (90,8 LPM) 32.7 psi (2,25 bar) I 24 GPM (90,8 LPM) 32.7 psi (2,25 bar) I 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) 1 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details, TABLE B NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DISCHARGING DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) Page 6 of 8 TFP41O ELEVATION Maximum Coverage Area (a) Width x Length (b) Ft. x Ft. (m x m) 12 x 12 Maximum Spacing Ft. (m) Minimum Flow Ic) and Residual Pressure (II) Two sprinkler design with the sprinklers located along the slope and positioned to discharge across the slope. (111) Three sprinkler design when there are more than two sprinklers in a compartment and with the sprinklers located along the siope.and positioned to discharge across the slope. Top -Of -Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top -Of -Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C (3,7 x 3,7) 14 x 14 (4,3 x 4,3) 16 x 16 (4,9 x 4,9) 16 x 18 (4,9 x 5,5) 16 x 20 (4,9 x 6,1) 12 (3,7) 14 (4,3) 16 (4,9) 16 (4,9) 16 (4,9) 11 11 11 11 111 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) 11 11 11 11 111 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) 11 11 11 11 111 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) 11 11 11 11 111 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE C NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 4 Inch Rise for 12 Inch Run) TFP41O Page 7 of 8 ELEVATION Maximum Coverage Area fa) Width x Length (b) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Minimum Flow lc) and Residual Pressure (Ill) Three sprinkler design when there are more than two sprinklers In a compartment and with the sprinklers located along the siope.and positioned to discharge across the slope. Top -Of -Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) 155°F/68°C 175°F/79°C 12 x 12 (3,7 x 3,7) 12 (3,7) 11I 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) I11 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 11I 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 x 18 (4,9 x 5,5) 16 (4,9) N/A N/A 16 x 20 (4,9 x 6,1) 16 (4,9) N/A N/A (a) For coverage area dimensions Tess than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE D NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 4 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) Page 8 of 8 Care and Maintenance The Series LFII (TY1334) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb, (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a par- ticular purpose This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TFP41O Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (TY1334), K=4.2, Residen- tial Horizontal Sidewall Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155°F/68°C or Chrome Plated P/N 51-211-9-155 155°F/68°C White Polyester P/N 51-211-4-155 155°F/68°C White (RAL9010)* P/N 51-211-3-155 155°F/68°C Natural Brass P/N 51-211-1-155 175°F/79°C or Chrome Plated P/N 51-211-9-175 175°F/79°C White Polyester P/N 51-211-4-175 175°F/79°C White (RAL9010)* P/N 51-211-3-175 175°F/79°C Natural Brass P/N 51-211-1-175 *Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (spec- ify*). *Refer to Technical Data Sheet TFP770 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 WIL KINS a ZURN company FEATURES Sizes: ❑ 3/4" ❑ 1" 0 1 %4" ❑ 1'/" 0 2" Maximum working water pressure Maximum working water temperature Hydrostatic test pressure End connections Threaded OPTIONS (Suffixes can be combined) ❑ - with full port QT ball valves (standard) ❑ L - less ball valves ❑ U - with union ball valves O MS - with integral relief valve monitor switch ❑ P - for reclaimed water systems ❑ S - with bronze "Y" type strainer ❑ BMS - with battery operated monitor switch ❑ FDC - with fire hydrant connection; 2" only ❑ TCU - with test cocks up O V - with union swivel elbows ❑ SE - with street elbows ❑ FT - with integral male 45° flare SAE test fitting 175 PSI 180°F 350 PSI ANSI B1.20.1 ACCESSORIES Cl Air gap (ModelAG) O Repair kit (rubber only) O Thermal expansion tank (Model WXTP) O Soft seated check valve (Model 40) O Shock arrester (Model 1250) ❑ QT-SET Quick Test Fitting Set O Ball valve handle locks ❑ Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) r M «11» del 975XL Reduced Pressure Principle Assembly 0 s 11 111 BP -t 1:7 ..T APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. STANDARDS COMPLIANCE • ASSE® Listed 1013 • IAPMO® Listed • UL® Classified (less shut-off valves orwith OS&Yvalves) • C-UL® Classified • CSA® Certified • AVINVA Compliant C511 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southem California MATERIALS Main valve body Access covers Fasteners Elastomers Polymers Springs Cast Bronze ASTM B 584 Cast Bronze ASTM B 584 Stainless Steel, 300 Series Silicone (FDAApproved) Buna Nitrite (FDAApproved) Noryi , NSF Listed Stainless steel, 300 series Relief Valve discharge port 3/4" - 1" - 0.63 sq. 11/4"-2" - 1.19sq. in. MODEL SIZE in. mm 3/4 1 1 1/4 1 1/2 2 20 25 32 40 50 A in. 12 13 17 17 3/8 18 1/2 Page 1 of 2 mm 305 330 432 441 470 A UNION BALL VALVES in mm 14 14 1/4 19 20 21 1/4 356 362 483 508 540 DIMENSIONS approximate) B LESS BALL VALVES in. 7 3/4 7 3/4 10 15/16 10 15/16 10 15/16 mm 197 197 278 278 278 in. mm 2 1/8 2 1/8 2 3/4 2 3/4 2 3/4 54 54 70 70 70 in. mm 3 3 3 1/2 3 1/2 3 1/2 76 76 89 89 89 in. 3 1/2 3 1/2 5 5 5 WEIGHT mm F in. mm in. G LESS VALVES BALL WITH VALVES BALL 89 5 127 15 3/4 mm 400 lbs. kg lbs. kg 89 5 127 17 3/4 451 10 4.5 12 5.5 127 6 3/4 171 22 559 10 22 4.5 10 14 28 6.4 12.7 127 6 3/4 171 23 1/8 587 127 6 3/4 171 25 1/2 648 22 22 10 28 12.7 10 34 15.4 DOCUMENT St: BF-975XL lc REVISION: 1/06 GU 15 10 50 3/4" (20mm) 1" (25mm) r 20 MI An a, FLOW CHARACTERISTICS MODEL 975XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (Us) 1.26 2.52 3.8 5.0 20 15 10 3.2 6.3 9.5 12.6 15.8 137 1 1 4" (32mm) 1 h" (40mm 2" (50mm) 5 50 FLOW RATES (GPM) O Rated Flow (Established by approval agencies) 100 150 200 35 250 TYPICAL INSTALLATION Local codes shall govern installation re- quirements. To be installed in accor- dance with the manufacturers' instruc- tions and the latest edition of the Uni- form Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above ad- equate drains with sufficient side clear- ance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. 1 i►�r, ►r:■ CENTRAL STATION ALARM PANEL BATTERY MONITOR SWITCH AIR GAP FITTING DIRECTION OF FLOW INDOOR INSTALLATION (Shown w/optional BMS) Capacity thru Schedule 40 Pipe P ip a size 5 ft/sec 7 .5 ft/sec 10 ft/sec 1 5 ft/s e c 1 /8" 1 1 2 3 1 /4" 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 1" 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 OPT ONAL WATER METER PROTECTIVE ENCLOSURE DIRECTION OF FLOW INLET SHUT-OFF OUTDOOR INSTALLATION SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylIm and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. Page 2 of 2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax 805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax 905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Webslte: http•//www.zurn.com TOLCO (,+NIBCO WWW,toIco,com Revision 3/31/2003 Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre -Galvanized Function — Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCOTM Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design* pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been know to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Note — Fastener into light gauge metal may be ordered separately. Minimum acceptable: #10 x 1" Hardened Self Threading Screw with 5/16" hex washer head. Order By — Figure number and CPVC pipe size. * Patent Pending @c® CPVC Max. Hanger Fastener Hex Ap Dimensions • Weights Pipe Size AB C ,__ ___. Spacing (Ft.) Head Size Wt./1o0 3/�4 23/4e 1e/,e 13/,6 5'/z 5/16 2"/,e 1'/,a 13/,e 9 ' 6 5/169 1 /< 3'/,e 15/a 13/,e 6,/2 1 /z 2 3a/,e 5/16 11 1 /4 13/4e 7 5/16 12 33/4 2'/e 13/1e 8 5/16 15 38 Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92879 • Plir 95 5;, Customer Service • 800 786 5266 wwwtolco.eom TOLCO i>ntim rI NIBCO www.tolco,com Revision 5/24/2001 Fig. 22C - Combination Hanger & Restrainer Application Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre -Galvanized Function — Designed to support a CPVC pipe away from the corner of a beam. This position allows for easy installation of drops or risers without adding additional wood blocks. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) for use as a combination hanger and restrainer. Finish — Pre -Galvanized Note — Approved UL Listed fastener into wood is furnished with the product. A fastener into light gauge metal may be ordered separately. Minimum acceptable #10 x 1" hardened self threading screw with 5/16" hex washer head. Order By — Fig. 22C application is composed of two standard Fig. 22 models — order two singles for each hanger and restrainer application required. TRUSS HEADER OR TRUSS JOIST (TYP) 5195 Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92879 • Ph: 951.737.5599 • fax: 951.737 0330 Customer Service • 800.786.5266 www.toleo.com TOLCO NIBCO WWW,tolco.com Revision 5/24/2001 Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre -Galvanized Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design` protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allow- ing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Order By — Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 3 /e 19/+e 13/+e 51/2 5/16 9 1 Y, 3% 1 �/+a 13/1e 6 5/16 2 /az 1'/+e 6+/2 5/16 11 2 4'/8 27/+e 13/+e 8 5/16 15 8 5/16 15 CPVC Max. Hanger Fastener Hex Approx. Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92879 • Ph Customer Service • 800, 786 5266 www.tolco.com Dimensions • Weights Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 25/ie 15/32 13/,e 572 5/16 9 1 25/e 15/,e 13/,5 6 5/16 9 1'/, 3 11/2 13/,e 6'/2 5/16 11 11/2 3'/% 15/e 1/m 7 3 „ 5/16 12 2 3 /,e 1s'/32 13/,e 8 5/16 15 br nil nl NIBCC] www.tolco.com Revision 5/24/2001 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre -Galvanized Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Order By — Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. CPVC Max. Hanger Fastener Hex Approx. Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92879 • Ph: 951.737.5599 • Fax: 951.737 0330 Customer Service • 800 786 5266 www.tolco.com