HomeMy WebLinkAboutFire Alarm Systems 800 MacGregor Ave 2006Api System Group,Inc 7020-B S.Tucson Way Englewood,Co 80112 (303)799-9189 /(303)792-2965 Black Canyon Inn 800 Macgregor Avenue Estes Park,Colorado 80517 Fire Alarm System Cut Sheets May 22,2006 NFW-100 Fire alarm control panel,Intelligent MCBL-7 DACT phone cords,7’ ES12-12 12 amp/hour battery,12 volt NOT-BG12LX Manual pull station,intelligent NP-100 Photoelectric smoke detector,intelligent NDM-100 Dual monitor module,intelligent DSM-12/24-R Dual sync module,red MIZ-24S-W Piezoelectric mini horn,white ASWP-2475W-FR Sync horn/strobe,75 cd,red,weather proof GENERAL The NOTIFIER FireWarden-100 (NFW-100)is a compact, cost-effective,intelligent addressable fire alarm control panel with a capacity of 198 addressable NOTIFIER de vices on one Signaling Line Circuit (SLC)and a built-in 14.4K Baud modem for remote site upload/download or remote monitoring. The Signaling Line Circuit (SLC)loop supports up to 99 addressable detectors including photoelectric,photoelectric with heat,ionization,photoelectric duct,fixed heat,and fixed heat with rate-of-rise detectors.It also supports up to 99 addressable modules including monitor (two-wire detec tor,normally open devices),conventional two-wire smoke monitor (supervise compatible two-wire smoke detectors), and relay (two Form-C)modules.The panel uses surface- mount technology and is designed for ease of installation, programming,and maintenance.It features the latest in advanced fire protection technology,including mainte nance alert and automatic detector test functions. SPECIAL FEA TURES: •Built-in 14.4K Baud modem. •Selectable strobe synchronization per NAC. •Remote site upload/download. •Four Class B or two Class A NAC circuits. FEATU RES SLC Loop: •SLC can be configured for NFPA Style 4,6,or 7 operation. •SLC supports up to 198 addressable devices (99 de tectors and 99 monitor,control,or relay modules),in cluding addressable smoke detectors,heat detectors, and duct detector. •SLC loop maximum length 10,000 ft.(3,048 m)@ 12 AWG (3.1 mm2).Requires twisted,shielded wire (3,000 ft./914.4 m untwisted,unshielded wire). Notification Appliance Circuits (NA Cs): •Four onboard NACs with additional NAC capability us ing output control modules (NC-i 00). •Silence Inhibit and Auto Silence timer options. •Continuous,March Time,Temporal or California code for main circuit board NACs with two-stage capability. •Selectable strobe synchronization per NAC. •5.0 amps total NAC power with XRM-24. Advanced Fire Technology: •Sensitivity testing with printable results,onsite or offsite. •Automatic drift compensation. Programming and Software: •Autoprogram (learn mode)reduces installation time. •Fully programmable from local keypad,local PS-2 key board or PC via VFWARDEN-CD Windows®utility. 0 LISTED S635 •Remote site upload/download capability. •Two-level user-programmable passwords. •Custom English labels (per point)may be manually en tered or selected from an internal library file. •Two programmable Form-C relay outputs. •99 software zones. User Interface: •Built-in 14.4K Baud modem (DACT). •Remote Acknowledge,Silence,Reset and Drill via addres sable monitor modules,ACS Series annunciators or FDU-80 remote annunciator. •EIA-232 printer/PC interface (variable baud rate)on main circuit board. •Integral 80-character LCD display with backlighting. •Real-time clock/calendar with automatic daylight savings adjustments. •History file with 1,000-event capacity. •EIA-485 supporting up to 32 ACS Series annunciators. •EIA-485 supporting up to 32 FDU-80 annunciators. •Maintenance alert warns when smoke detector dust ac cumulation is excessive. •Automatic device type-code verification. cont’d pg.3 May 9,2005 DN-7005 •A1-100cNOTIFIER®FireWarden-100 Intelligent Addressable FACP (NFW-1 00) by Honeywell with Built-In 14.4K Baud Modem Section:Addressable California State Fire Marshal 7165-0028:235 This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or ISO 9001anticipateallrequirements.All specifications are subiect to change without notice. For more information,contact NOTIFIER.Phone:(203)484-7161 FAX:(203)484-7118 a I IcNOT!FIER [NGlNElMNliFPJ1U by Honeywell 12 Clintonville Road,Northford,Connecticut 06472 QUALITY SYSTEMS MadeiritheU.5.A. DN-7005 •05/09/05 —Page 1 of 4 24 VOC r-—-i-Lc0f1 FDU-80 Up to 6,000 ft.(1825.8 m) between each FDU-80 in the EIA-485 loop,and between each FDU-80 and the FACP ANNUNCIATORS AFM-LED,LDM, ACSIACM HUUU 8 FORM-C,5-AMP RELAYS (optional,order ACM-8R) 1 Ni i SMOKE DETECTORS NP-i 00,NP-i OUT,NI-i 00 HEAT DETECTORS NH-lOU,NH-i OOR DUCT DETECTOR ND-lOU,ND-100R MONITOR I CONTROL NMM-iOO,NZM-iOO, NDM-100,Ni00-ISO, NC-iOU,NC-iOOR MINI MONITOR NMM-100P Wire Distance Requirements in Feet (m)Typical Wire Size Twisted-pair,shielded 10,000 feet 12 AWG (3.1 mm2):Belden 9583,Genesis 4410, (3,048 m)Signal 98230,WPW D999. Twisted-pair,shielded 8,000 feet 14 AWG (2.00 mm2):Belden 9581,Genesis 4408, (2,438 m)Signal 98430,WPW D995. Twisted-pair,shielded 4,875 feet 16 AWG (1.3 mm2):Belden 9575,Genesis 4406 (1,486 m)and 4606,Signal 98630,WPW D99i. Twisted-paifl shielded 3,225 feet 18 AWG (0.78 mm2):Belden 9574,Genesis 4402 (983 m)and 4602,Signal 98300,WPW D975. Unwisted,unshielded 3,000 feet (915 m)12—18 AWG (3.1 —0.78 mm2). 52293t1 Ib! EIA -485 INTERFACE (DIM-485)built into I the motherboard (four wires) Fire Warden-100 Fire Alarm Control! Communicator Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTM) 24 VDCll.ll EIA -485 in ACS mode (two wires) --NACs (Notification Appliance Circuits)—*BELLS,SIGNALS,STROBES EIA-232 INTERFACE (PIM-24)built into the motherboard PRINTER NOTE:System can use either the printer OR the FDU-80. They cannot be used simultaneously. WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit operation.It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical interference.Wire size should be no smaller than 18 AWG (0.78 mm2)and no larger than 12 AWG (3.1mm2).The wire size depends on the length of the SLC circuit.Use the table below to determine the specific wiring requirements for the SLC. PULL STATION NOT-BG12LX 7005d1 w,,! Page 2 of 4 —DN.7005 •05/09/05 •One person audible or silent walk test with walk-test log and printout. •Point trouble identification. •Local piezo sounder. •Waterflow (nonsilenceable)selection per monitor point. •System alarm verification selection per detector point. •PAS (Positive Alarm Sequence)and presignal delay per point (NFPA 72 compliant). •Optional 4XTM module (conventional reverse polarity/city box transmitter). CONTROLS AND INDICATORS LED INDICATORS 1.AC POWER (green) 2.FIRE ALARM (red) 3.SUPERVISORY (yellow) 4.ALARM SILENCED (yellow) 5.SYSTEM TROUBLE (yellow) 6.MAINTENANCE (yellow) 7.DISABLED (yellow) 8.BATTERY FAULT (yellow) 9.GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS 1.ACKNOWLEDGE/STEP 2.ALARM SILENCE 3.DRILL 4.SYSTEM RESET (lamp test) 5—16.12-key pad with full alphabet 17—20.4 cursor keys 21.ENTER FIELD-PROGRAMMING FEATURES OFFL.INE PROGRAMMING:Create the entire program in your office using a Windows®-based software package (or der programming kit VFWARDEN-CD separately).Up load/download system programming locally to the FireWarden-100 in less than one minute. AUTOPROGRAMMING:Command the FireWarden-100 to program itself (takes less than 30 seconds).In the Auto- Program mode,the FireWarden-100 scans for all possible devices at all addresses,stores the device types,and ad dresses found,and then loads default values for all op tions (General Alarm).It also checks for two or more de vices set to the same address. ONLINE EDIT:While still providing fire protection,the FireWarden-100 may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. ENGLiSH LABEL LIBRARY:Quickly select labels from a standard library of more than 50 adjectives/nouns,such as ‘FLR 3 HALLWAY,”or enter custom labels letter-by-letter. Use recall function to repeat previously used label. PROGRAM CHECK:Automatically catch common errors, such as control modules not linked to any zone or input point. MAINTENANCE ALERT The FireWarden-iQO continuously monitors each smoke detector and is capable of reporting maintenance condi tions.This reduces the risk of false alarms due to dust accumulation.Refer to the control panel installation manual for more information. AUTOMATIC TEST OPERATION The FireWarden-100 performs an automatic test of each detector every two hours.Failure to meet the test limits causes a TESTF trouble type.System Reset clears this trouble. NFPA STANDARDS The FireWarden-100 complies with the following NFPA 72 Fire Alarm Systems requirements: •LOCAL (Automatic,Manual,Waterf low and Sprinkler Su pervisory). •AUXILIARY (Automatic,Manual and Waterflow)(requires 4XTM). •REMOTE STATION (Automatic,Manual and Waterflow) (requires 4XTM). •PROPRIETARY (Automatic,Manual and Waterflow). •CENTRAL STATION (Automatic,Manual and Waterflow, and Sprinkler Supervised). SPECIFICATIONS AC Power —TB1:120 VAC,60 Hz,3.0 A.Wire size:mini mum 14 AWG (2.0 mm2)with 600 V insulation. Battery (lead acid only)—TB2:Maximum charging circuit: Normal flat charge 27.6 VDC @ 0.80 A.Maximum battery charger capacity:18 AH.FireWarden-100 cabinet holds maximum of two 18 AH batteries.For 25—120 AH batter ies,use the CHG-120 or CHG-75 Battery Charger and BB 55 Battery Box. NOTE:Jumper JP3,on the FACP main circuit board must be cut to disable the FACP battery charger when using the CHG-120. Remote Synchronization Output —TB2:A 24 VDC,40 mA signal that mimics the sync signal of NAC 1 and can be utilized by remote power supplies such as the FCPS-24S6/ -24S8.This allows NAC devices attached to the power supply to synchronize with the devices connected to NAC 1 of the FACP. Communication Loop —(standard)TB8:24 VDC nomi nal,27.6 VDC maximum.Maximum length:10,000ff.(3048 m)total twisted,shielded pair length.Maximum loop cur rent 400 mA (short circuit)or 100 mA (normal).Maximum loop resistance:40 ohms.Supervised and power-limited. Notification Appliance Circuits —TB4:Power-limited cir cuitry.Maximum voltage drop in wiring:2.0 VDC.Nominal operating voltage:24 VDC.Current limit:fuseless,electronic, power-limited circuitry.Maximum signaling current per cir cuit:2.50 A.End-of-Line Resistor:4.7K ohm,1/2 watt (P/N 71252,UL Listed)for NACs.Refer to NOTIFIER Device Compatibility Document for listed compatible devices. Programmable and Trouble Output Relays —TB5,TB6, TB7:Contact rating:2.0 A @ 30 VDC (resistive),0.5 A @ 30 VAC (resistive).Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal)—TB1,Terminals 3 (+)&4 (—):Maximum ripple voltage:10 mVRM5.Up to 0.5 A for powering four-wire smoke detectors.Power-limited circuit.Refer to NOTIFIER Device Compatibility Document for listed compatible de vices. Nonresettable Power #1(24 VDC Nominal)—TB1,Termi nals 3 (+)&4 (—):Maximum ripple voltage:10 mVRMs.Up to 0.5 A total DC current available from each output.Power- limited circuit.TB1,Terminals 1 (+)&2 (—)can be config ured as resettable 24 V or non-resettable via JP4. NOTE:If using optional XRM-24,total NAC and auxiliary cur rent draw cannot exceed 6.0 amps. EIA-485 (ACS)—TB6:ACS annunciator connector,Termi nal 1 (+)and Terminal 2 (—). EIA-485 (TERM)—TB7:Terminal mode annunciator con nector,Terminal 1 (Out +),2 (In ÷),3 (Out —),4 (In —). EIA-232 —TBB:PC/printer connector,Terminal 1 (Trans mit),2 (Receive),3 (DTR),4 (Ground). DN-7005 •05/09/05 —Page 3 of 4 CABINET SPECIFICATIONS Door:18.67 (47.43 cm)high x 15.78”(40.08 cm)wide x 1.08”(2.74 cm)deep.Backbox:18.50”(47.0 cm)high x 15.50”(39.37 cm)wide x 4.37”(11.1 cm)deep.Trim Ring (NFW-TR):21.62”(54.92 cm)high x 18.62”(47.3 cm)wide. PRODUCT LINE INFORMATION NEW-I 00:198-point addressable Fire Alarm Control Panel. Includes 80-character LCD display,single printed circuit board,and cabinet. ACM-8R:Optional plug-in relay module provides 8 Form-C 5.0 A relays. VEWAR DEN-CD:Contains panel programming software for Windows®-based PC computer (cable not included). DP-EW-iOO:Dress panel for FireWarden-iQO. NFW-TR:Trim Ring for semi-flush mounting. BB-55:Battery box,required to house two BAT-i 2260 batteries and one CHG-120 battery charger.For batteries greater than 26 AH,consult factory for housing/mounting arrangements. BB-6:Battery backbox,holds up to two BAT-i 2260 batteries. CIIG-120:Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH.CHG-120 or CHG 75 required for charging greater than 25 AH batteries. CHG-75:Battery charger for lead-acid batteries with a rating of 25 to 75 AH.CHG-120 or CHG-75 required for charging greater than 25 AH batteries. BAT-i2180:Battery,12 volt,18.0 AH,(two required). BAT-i 2260:Battery,12 volt,26 AH,(two requireci requires CHG-75). BAT-i 2550:Battery,12 volt,55 AH,(two required;requires CHG-75). PRT/PK-CABLE:Cable printer/personal computer interface cable.For use with printer or VFWARDEN-CD. Windows®is a registered trademark of Microsoft Corporation. COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-i 00:Addressable low-profile ionization smoke detector. NP-i 00:Addressable low-profile photoelectric smoke detector. NP-lOOT:Addressable low-profile photoelectric smoke detector with thermal sensor. NH-iO0:Fast-response,low-profile heat detector. NH-100R:Fast-response,low-profile heat detector with rate-of-rise. ND-l00:Photoelectric duct smoke detector. ND-100R:Photoelectric duct smoke detector with relay. NMM-i00:Addressable Monitor Module for one zone of normally-open dry-contact initiating devices.Mounts in standard 4.0”(10.16 cm)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B (Class B)or Style D (Class A)IDC. NMM-100P:Miniature version of NMM-i00.Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-i00:Similar to NMM-100,but may monitor up to 20 conventional two-wire detectors.Requires resettable 24 VDC power.Consult factory for compatible detectors. NDM-100:Dual Monitor Module.Same as NMM-100 except it provides two Style Y (Class B)only lDCs. NC-i 00:Addressable Control Module for one Style Y/Z (Class B/A)zone of supervised polarized Notification Appliances.Mounts directly to a 4.0”(10.16 cm)electrical box.Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-i OOR:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch. Mounts directly to a 4.0”(10.16 cm)box,surface mount using the SMB500. NOT-BG12LX:Addressable manual pull station with interface module mounted inside. Ni00-ISO:Fault Isolator Module. SMB500:Used to mount all modules except the NMM loop. NOTE:For more information on Compatible Addressable De vices for use with the Fire Warden-100,see the following data sheets (document numbers):Nba-ISO (DN-6994),NP-100/NP- lOOT (DN-6995),NI-lao (DN-6996),NH-laO/NH-bOOR (ON- 6997),ND-100/ND-i OOR (DN-7006),NMM-iO0/NMM-i OOP/ NDM-IOO/NZM-100 (DN-6999),NC-i 00/NC-bOOR (DN-7000), and NOT-BG12LX (DN-7001). COMPATIBLE ANNUNCIATORS EIA-485 interface:Built into the motherboard. AEM-LED Zone Series:LED-type fire annunciators capable of providing up to 99 software zones of annunciation.Avail able in increments of 16 or 32 with expandable (AFM-X Se ries)and non-expandable (AFM Series)configurations to meet a variety of applications. ACS/ACM Annunciator Series:Allows annunciation of loop modules and detectors. LDM Graphic Series:Lamp Driver Module series for use with custom graphic annunciators. EDU-80 (Liquid Crystal Display)point annunciator:80- character,backlit LCD-type fire annunciators capable of displaying English-language text.Up to 32 FDU-80 annun ciators may be connected to the EIA-485 terminal mode serial interface on the FireWarden-iOO motherboard. NOTE:For more information on Compatible Annunciators for use with the Fire Warden-lOU,see the following data sheets (document numbers)AFM/AFM-X Series (DN-0056),ACM-BR (DN-3558),A CS/ACM Series (DN-0524),FDU-80 (DN-6820), LDM Series (DN-0551). AGENCY LISTINGS AND APPROVALS See the first page of this data sheet for listing agencies and file numbers.These listings and approvals apply to the basic FireWarden-iOO control panel.In some cases, certain modules may not be listed by certain approval agen cies,or listing may be in process.Consult factory for latest listing status. Page 4 of 4 —DN.7005 •05/09/05 GENERAL The NOTIFIER NOT-BG12LX is a state-of-the-art,dual-ac tion (i.e.,requires two motions to activate the station)pull station that includes an addressable interface (mounted in side)for NOTIFIER’s addressable FireWarden-100 fire alarm control panel.Because the NOT-BG12LX is addressable, the control panel can display the exact location of the acti vated manual pull station.This leads fire service personnel quickly to the location of the alarm. FEATURES •Aesthetically pleasing,highly visible,dual-action design. •Meets ADA 5 lb.maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. •Mounts,semi-flush,to a standard single-gang (2.125” [5.398 cm]minimum depth),double-gang,or 4.0’(10.16 cm)square electrical box. •When the handle latches in down position,the word ‘AC TIVATED”appears at the top of the handle in bright yellow to clearly indicate the station has been operated. •Key/lock reset;needs only a 1/4-turn to locklunlock. •Includes Braille text on station handle. •Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). •Optional trim ring (BG-TR). •Meets UL 38,Standard for Manually Actuated Signaling Boxes. •Maintenance personnel can open station (for inspection and testing)without causing an alarm condition. •Built-in bicolor LED,which is visible through the handle of the station,flashes red in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code,with a key- operated reset lock in order that they may be tested,and so designed that after actual Emergency Operation,they can not be restored to normal except by use of a key.An oper ated station shall automatically condition itself so as to be visually detected as activated.Manual stations shall be con structed of red-colored LEXAN®(or polycarbonate equiva lent)with clearly visible operating instructions provided on the cover.The word FIRE shall appear on the front of the stations in white letters,1.00 inches (2.54 cm)or larger.Sta tions shall be suitable for surface mounting on matching backbox SB-b or SB-I/O;or semi-flush mounting on a stan dard single-gang,double-gang,or 4.0”(10.16 cm)square electrical box,and shall be installed within the limits defined LEXAN®is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Patented,U.S.Patent No.D428,351;6,380,846 U.S.Patent Pending:091686,286 LISTED 5692 by the Americans with Disabilities Act (ADA)or per national! local requirements.Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops.The manual station shall,on com mand from the control panel,send data to the panel repre senting the state of the manual switch.Manual stations shall provide address setting by use of rotary decimal switches. September 16,2004 DN-7001 Al -380 ®NOT-BG12LX (‘)N OT I F I E R Addressable Manual Pull Station for FireWarden-1 00 Section:Addressable The NOT-BGI2LX Addressable Manual Pull Station ELECTRICAL SPECIFICATIONS Normal operating voltage:24 VDC. Maximum SLC loop voltage:28.0 VDC. Maximum SLC loop current:230 pA. NOTIFIER®is a Honeywell company. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.For b d I I 4 .1moreinformation,contact NOTIFIER.Phone:(203)484-7161 FAX:(203)484-7118 [NGlN[[RlG &MMOFA1111RlNNOTIFlERn12clintonvilleRoad,Northford,connecticut 06472 I UALIT Y SYSTEMS DN-7001•09/16104 —Page 1 of I NSTALLATION The NOT-BG12LX can be semi-flush mounted into a single- gang,double-gang,or standard 4.0”(10.16cm)square elec trical outlet box,or surface mounted to the Model SB-b or SB-I/O surface backbox.If the NOT-BG12LX is semi-flush mounted,then the optional trim ring (BG-TR)may be used. The BG-TR is usually needed for semi-flush mounting with 40”(10.16 cm)or double-gang boxes (not with single-gang boxes). CONSTRUCTION Shell,door,and handle are molded of durable LEXAN®(or potycarbonate equivalent)with a textured finish. OPERATION Pushing in,then pulling down on the handle causes it to latch in the down/activated position.Once latched,the word ACTIVATED”(in bright yellow)appears at the top of the handle,while a portion of the handle protrudes from the bot tom of the station.To reset the station,simply unlock the station with the key and pull the door open.This action re sets the handle;closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops.Each manual station,on command from the control panel,sends data to the panel representing the state of the pull station switch.Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION NOT-BG1 2LX Dual-action addressable pull station. TERMINAL CONNECTIONS 1 SLC (—) 2 SLC (+) SB-b SB-I/O BG-TR Includes key lock/reset feature. Surface backbox. Surface indoor/outdoor backbox. Optional trim ring. Back of station without door. Cover open to show easy access to miniature monitor module,rotary switch,and UL label. Page 2 of 2 —DN-7001•09/16/04 GENERAL The NP-i 00 and NP-i OOT addressable,low-profile plug- in photoelectric detectors use a state-of-the-art photoelec tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFI ER’s Fire Warden-i 00 Addressable Fire Alarm Con trol Panel (FACP).The NP-lOOT adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).Since these detectors are addressable,they will help emergency personnel quickly locate a fire during its early stages,po tentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to pro vide a local,visible sensor indication.Remote LED an nunciator capability is available as an optional accessory (P/N RA400Z). FEATU RES SLC loop: •Two-wire loop connection. •Unit uses base for wiring. Addressing: •Addressable by device. •Direct Decade 01 —99 (FireWarden-100)entry of ad dress. Architecture: •Unique single-source,dual-chamber design to respond quickly and dependably to a broad range of fires. •Sleek,low-profile design. •Integral communications and built-in type identification. •Built-in tamper-resistant feature. •Removable cover and insect-resistant screen for simple field cleaning. Operation: •Withstands air velocities up to 4,000 feet-per-minute (20 rn/sec.)without triggering a false alarm. •Factory preset at 1.5%nominal sensitivity for panel alarm threshold level. •Visible LED “blinks”when the unit is addressed (com municating with the fire panel)and latches on in alarm. Mechanicals: •Sealed against back pressure. •Direct surface mounting or electrical box mounting. •Mounts to:single-gang box,3.5’(8.89 cm)or 4.0(10.16 cm)octagonal box,or 4.0”(10.16 cm)square electrical box (using a plaster ring —included). Other system features: •Fully coated circuit boards and superior RF/transient protection. NP-i 00 with B71OLP base - I:IIIIII,r:_5935pho1 jpg •94-Va plastic flammability rating. •Low standby current. Options: •Remote LED output connection (P/N RA400Z). SPECIFICATIONS Voltage range:15—32 VDC (peak). Standby current:300 pA @ 24 VDC. LED current:6.5 mA @24 VDC (latched “ON’). Air velocity:4,000 ft/mm.(20 rn/sec.)maximum. Diameter:6.1’(15.5 cm)installed in B71OLP base. Height:2.1”(5.33 cm)installed in B71 OLP base. Weight:3.6 oz.(102 g). Operating temperature range:for NP-100:0°C to 49°C (32°F to 120°F);for NP-i O0T 0°C to 38°C (32°F to 100°F). Temperature:0°C—49°C (32°F—120°F). Relative humidity:10%—93%,non-condensing. May 9,2005 DN-6995 Al -310 NOTIFIER®NP-100 and NP-lOOT by Honeywell Addressable Photoelectric Detectors Section:Addressable LISTED S1115 California/:-N State Fire Marshal 7272-0028:231 MARYLAND State Fire Marshal Permit #2173 NP-lOOT with B71OLP base This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact NOTIFIER.Phone:(203)484-7161 FAX:(203)484-7118 ©NOT I F I E R’ENGINEERING&MI1NUFAEIURING by Honeywell 12 Clintonville Road,Northtord,Connecticut 06472 QUALITY S YST EMS n-ri F I DN-6995 •05/09/05 —Page 1 of 2 APPLICATIONS Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability,espe cially where smoldering fires are anticipated.Ionization detectors are often better than photoelectric detectors at sensing fast,flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-i 00(T)plug-in,low-profile smoke detectors are de signed to commercial standards and offer an attractive appearance. LEXAN®is a registered trademark of GE Plastics,a subsidiary of General Electric Company. INSTALLATION NP-i0O(T)plug-in detectors use a detachable mounting base to simplify installation,service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep.Suitable boxes include: •4.0 (10.16 cm)square box with plaster ring. •4.0 (10.16 cm)octagonal box. •3.5”(8.89 cm)octagonal box. •Single-gang box. NOTE:Because of the inherent supervision provided by the SLC loop,end-of-line resistors are not required.Wiring “T taps”or branches are permitted for Style 4 (Class B)wiring. OPERATION Each NP-100(T)uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC).It re sponds to regular polls from the system and reports its type and status. The NP-100(T)addressable photoelectric sensor’s unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.)with out sending an alarm level signal.Because of its unipolar chamber,the NP-iO0(T)is approximately two times more responsive than most photoelectric sensors.This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72,Chapter 7 on Inspection,Testing and Mainte nance)when installed/connected to a FireWarden-1 00 ad dressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-1 00 for record keeping. PRODUCT LINE INFORMATION NP-ba NP-lOOT Same as NP-i00 but with thermal element; B71OLP base included.* Remote LED.Mounts to a single-gang box. Plug-in detector base.Dimensions:6.1(15.5 cm).Mounting:4.0 (10.16 cm)square box with or without plaster ring,4.0’(10.16 cm) octagonal box,3.5’(8.89 cm)octagonal box, or single-gang box.All mounting boxes have a minimum depth of 1.5”(3.81 cm). B224RB Plug-in System Sensor relay detector base. Diameter:6.2”(15.75 cm).Mounting:4.0” (10.16 cm)square box with or without plaster ring,4.0”(10.16 cm)octagonal box,or 3.5’ (8.89 cm)octagonal box.All mounting boxes have a minimum depth of 1.5”(3.81 cm). B224B1 Plug-in System Sensor isolator detector base.Maximum 25 devices between isolator bases (see DN-6994).Diameter:6.2”(15.75 cm).Mounting:4.0”(10.16 cm)square box with or without plaster ring,4.0”(10.16 cm) octagonal box,or 3.5”(8.89 cm)octagonal box. All mounting boxes have a minimum depth of 1.5”(3.81 cm). B5O1BH Plug-in System Sensor sounder detector base.Diameter:6.0”(15.24 cm).Mounting: 4.0”(10.16 cm)square box with or without plaster ring.Mounting box has a minimum depth of 1.5”(3.81 cm). “Prior to 03/28/05,the B7IQLP base was sold separately. Addressable photoelectric detector;B71 OLP base included.* RA400Z B71OLP Page 2 of 2 —DN-6995 •05/09/05 GENERAL Four different monitor modules are available for NOTIFIER’s FireWarden-100 intelligent fire alarm control panels to suit a variety of applications.Monitor modules are used to supervise a circuit of dry-contact input de vices,such as conventional heat detectors and pull sta tions,or monitor and power a circuit of two-wire smoke detectors (NZM-1 00). NMM-100 —The NMM-l00 Monitor Module is a standard- sized module (typically mounts to a 4.0’[10.16 cm]square box)that supervises either a Class A (Style D)or Class B (Style B)circuit of dry-contact input devices. NMM-IOOP —The NMM-100P is a Miniature Monitor Mod ule (a mere 1.3”(3.302 cm)H x 2.75 (6.985 cm)W x 0.5 (1.270 cm)D)used to supervise a Class B (Style B)cir cuit.Its compact design allows the NMM-100P to be mounted in a single-gang box behind the device it is moni toring. NZM-100 —The NZM-l00 Interface Module is a stan dard-sized module used to monitor and supervise com patible two-wire,24 volt,smoke detectors on a Class A (Style D)or Class B (Style B)circuit. NDM-1 00 —The NDM-100 Dual Monitor Module is a stan dard-sized module (typically mounts to a 4.0 [10.16 cm] square box)that supervises two Class B (Style B)circuits of dry-contact input devices. NMM-100 MONITOR MODULE •Built-in type identification automatically identifies this de vice as a monitor module to the control panel. •Powered directly by two-wire SLC loop.No additional power required. •High noise (EMF/RFI)immunity. •SEMS screws with clamping plates for ease of wiring. •Direct Decade 01 —99 (FireWarden-100)entry of ad dress. •LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel ligent,two-wire systems,where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC)for normally- open-contact fire alarm and supervisory devices. NMM-100 Applications —Use to monitor a zone of four-wire smoke detectors,manual fire alarm pull stations, waterflow devices,or other normally-open dry-contact alarm activation devices.May also be used to monitor normally-open supervisory devices with special supervi sory indication at the control panel.Monitored circuit may be wired as an NFPA Style B (Class B)or Style D (Class D) Initiating Device Circuit.A 47K ohm End-of-Line Resistor (provided)terminates the Style B circuit.No resistor is re ØMEA) 72-01-F Vol.11 LISTED (except NDM-100) S635 quired for supervision of the Style D circuit.Maximum DC resistance is 1,500 ohms. NMM-100 Operation —Each NMM-100 uses one of 99 (FireWarden-100)available module addresses on an SLC loop.It responds to regular polls from the control panel and reports its type and the status (open/normal! short)of its Initiating Device Circuit (IDC).A flashing LED indicates that the module is in communication with the con trol panel.The LED latches steady on alarm (subject to current limitations on the loop). May 9,2005 DN-6999 •Al -350 N OT I F I E R®Addressable Monitor Modules for the FireWarden-100: by Honeywell NMM-1 00,NMM-1 00P1 NZM-1 00,NDM-1 00 Section:Addressable California State Fire Marshal 7300-0028:230 (except NDM-100) NMM-100 and NZM-100 NMM-100 Specifications Nominal operating voltage:15 to 32 VDC. Maximum current draw:5.1 mA (LED on). Average operating current:400 hA (LED flashing). EOL resistance:47K ohms. Temperature range:32°F to 120°F (0°C to 49°C). Humidity range:10%to 93%norfcondensing. Dimensions:4.5”(11.43 cm)high x 4.0’(10.16 cm)wide x 1.25’(3.175 cm)deep.Mounts to a 4.0”(10.16 cm)square x 2.125”(5.398 cm)deep box. This document is not intended to be used for installation purposes.We try to keep our product information up-to.date and accurate.We cannot cover all specific applications or anticipate all requirements.All specitications are subject to change without notice. For more information,contact NOTIFIER.Phone:(203)484-7161 FAX:(203)484-7118()NOT I F I E R”ENGINEERINGRMANUFACTURING by Honeywell 12 Clintonville Road,Northford,Connecticut 06472 QUALIT Y SYSTEMS E IF IF I 0 DN-6999 •05/09/05 —Page 1 of 3 NMM-100P MINI MONITOR MODULE NZM-100 INTERFACE MODULE •Built-in type identification automatically identifies this de vice as a monitor module to the FireWarden-100. •Powered directly by two-wire SLC Loop.No additional power required. •High noise (EMF/RFI)immunity. •Tinned,stripped leads for ease of wiring. •Direct-dial entry of address (01-99 for FireWarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit.Its small size and light weight allow it to be installed without rigid mounting.The NMM-100P is intended for use in in telligent,two-wire systems where the individual address of each module is selected using rotary switches.It pro vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. NMM-IOOP Applications —Use to monitor a single device or a zone of four-wire smoke detectors,manual fire alarm pull stations,waterfiow devices,or other normally- open dry-contact devices.May also be used to monitor nor mally-open supervisory devices with special supervisory indication at the control panel.Monitored circuit/device is wired as an NFPA Style B (Class B)Initiating Device Cir cuit.A 47K ohm End-of-Line Resistor (provided)terminates the circuit. NMM-IOOP Operation —Each NMM-100P uses one of 99 (FireWarden-100)available module addresses on an SLC loop.It responds to regular polls from the control panel and reports its type and the status (open/normal/ short)of its Initiating Device Circuit (IDC). NMM-IOOP Specifications Nominal operating voltage:15 to 32 VDC. Average operating current:375 pA maximum. EOL resistance:47K ohms. Temperature range:32°F to 120°F (0°C to 49°C). Humidity range:10%to 93%noncondensing. Dimensions:1.3 (3.302 cm)high x 2.75°(6.985 cm)wide x 0.5”(1.270 cm)deep. Wire length:6.0 (15.24 cm)minimum. •Supports compatible two-wire smoke detectors. •Supervises DC wiring and connection of external power source (resettable). •High noise (EMF/RFI)immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address (01-99 for FireWarden-100). •LED flashes during normal operation. •LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in telligent,addressable systems,where the individual ad dress of each module is selected using built-in rotary switches.This module allows intelligent panels to inter face and monitor two-wire conventional smoke detectors. It transmits the status (normal,open,or alarm)of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com patible with the module. NZM-100 Applications —Use the NZM-100 to moni tor a zone of two-wire smoke detectors.The monitored cir cuit may be wired as an NFPA Style B (Class B)or Style D (Class A)Initiating Device Circuit.A 3.9 K ohm End-of-Line Resistor (provided)terminates the end of the Style B or D (class B or A)circuit (maximum IDC loop resistance is 25 ohms).Install ELR across terminals 8 and 9 for Style D application. NZM-100 Operation —Each NZM-100 uses one of 99 (FireWarden-100)available module addresses on an SLC loop.It responds to regular polls from the control panel and reports its type and the status (open/normal/ short)of its Initiating Device Circuit (IDC).A flashing LED indicates that the module is in communication with the con trol panel.The LED latches steady on alarm (subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage:15 to 32 VDC. Maximum current draw:5.1 mA (LED on). Average operating current:270 pA (LED flashing). EOL resistance:3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage:18 to 28 volts power limited.Ripple voltage: 0.1 VRMs maximum.Current:90 mA per module maximum. Requires regulated,resettable 24 VDC power. Temperature range:32°F to 120°F (0°C to 49°C). Humidity range:10%to 93%noncondensing. Dimensions:4.5°(11.43 cm)high x 4.0 (10.16 cm)wide x 1.25°(3.175 cm)deep.Mounts to a 4.0 (10.16 cm)square x 2.125°(5.398 cm)deep box. Page 2 at 3—DN-6999 •05/09/05 NDM-100 DUAL MONITOR MODULE •Built-in type identification automatically identifies this de vice as two monitor modules to the control panel. •Powered directly by the two-wire SLC loop.No additional power required. •High noise (EMF/RFI)immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address 01 —99 (FireWarden-100) uses two addresses per module. •LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent,two-wire systems,where the individual address of each module is selected using the built-in rotary switches.It provides two independent two-wire fault-toler ant Initiating Device Circuits (IDCs)at two separate,con secutive addresses.It is capable of monitoring normally open-contact fire alarm and supervisory devices,or either normally open or normally closed devices for non-fire ap plications. NDM-100 Applications —Use to monitor a zone of four-wire smoke detectors,manual fire alarm pull sta tions,waterflow devices,or other normally-open dry-con tact alarm activation devices.May also be used to monitor normally-open supervisory devices with special supervi sory indication at the control panel.Monitored circuit may be wired as an NFPA Style B (Class B)Initiating Device Circuit.The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit.Maximum IDC resistance is 1,500 ohms. NDM-100 Operation —Each NDM-100 uses two of 99 (FireWarden-100)available module addresses on an SLC loop.It responds to regular polls from the control panel and reports its type and the status (open/normal! short)of its Initiating Device Circuit (IDC).A flashing LED indicates that the module is in communication with the control panel.The LED latches steady on alarm (subject to current limitations on the loop). NDM-100 Specifications Nominal operating voltage:15 to 32 VDC. Maximum current draw:5.1 mA (LED on). Average operating current:750 pA (LED flashing). EOL resistance:47K ohms. Maximum IDC wire resistance:1,500 ohms. Temperature range:32°F to 120°F (0°C to 49°C). Humidity range:10%to 93%noncondensing. Dimensions:4.5°(11.43 cm)high x 4.0 (10.16 cm)wide x 1.25 (3.175 cm)deep.Mounts to a 4.0”(10.16 cm)square x 2.125 (5.398 cm)deep box. Accessories:SMB500 electrical box. INSTALLATION NMM-100,NZM-100,and NDM-100 modules mount di rectly to a standard 4.0 (10.16 cm)square,2.125 (5.398 cm)deep,electrical box.They may also be mounted to the SMB500 surface-mount box.Mounting hardware and in stallation instructions are provided with each module.All wiring must conform to applicable local codes,ordinances, and regulations.These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box.All wiring must conform to applicable local codes,ordinances and regulations. ARCHITECTS’/ENGI NEERS’ SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module. NZM-100 Two-wire detector monitor module. NDM-100 Dual monitor module. SMB500 Optional surface-mount backbox. aa a MOUNTING DIAGRAMS for slundurd-sized modules DN-6999 •05/09/05 —Page 3 of 3 GENERAL Wheelock’s patented 2-wireAS SeriesAudible Strobe Applicances and AH Series Audible Devices offer more features with low current draw. Strobe optionsforwall mount models include 1575cd orWheelock’s patented MCW multi-candela wall strobes with field selectrable candela settings of 15/30/75/11 Ocd. Ceiling mountmodels incorporate Wheelock’s patented MCC multi- candela ceiling strobe with field selectrable intensities of 15/30/75/ 95cd. The audible provides a selectable choice of either a continous horn or temporal pattern (Code 3)when constant voltage from a Fire Alarm Panel (FACP)is applied.Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or with a power supply with the Wheelock sync protocol, synchronization of the continous horn tone provides the temporal (code 3)tone (mandated by NFPA72)simultaneously forall audible appliances.This ensurses a distrinct temporal (code 3)pattern when 2 or more audibles are within hearing distance.If not synchronized the temporal sound could overlap and not be distrinctive.At the same time the strobes will be synchronized. This provides the ability to complywith ADA guidelines concerning photosensitive epilepsy and the NFPAstandardswhen installing 2 or more visual appliances within the field of view all of this puls the ability to silence the audible is achieved by using only 2 wire. FEATURES •ADNNFPAIUFC/ANSI Compliant •AS Series Audible Strobe Devices are available in wall and ceiling-mount models: Wallmountmodelsoffered are available with Field Selectrable Candela Settings of 15/30/75/11 Qcd or 1575cd (single candela model) Ceiling mount models offered are available with field selectrable candela settings of 15/30175/95cd •Selectable Continous Horn orTemporal (Code 3) •3 Selectrable dBA settings (99,95 abd 90 dBA)in both tones •Patented 2-Wire Audible Strobe Appliance •Patented Universal Mounting Plate •Weatherproofmodels are available for outdoor use •Strobes produce 1 flash persecond overthe regulated voltage range •12 and 24 VDC modelswith wide UL “Regulated Voltage Range” using filtered DC or unfiltered FWR input voltage •Synchronize with Wheelock SM,DSM or power supply with built-in Wheelock sync protocol •Fast installation with IN/OUT screwterrninals using #12 and #18 AWG wires APPROVED LISTED -::i California E 5946 State Fire Marshal“‘7125-0785:131 GENERAL NOTES MEA 151-92-E •Strobes are designed to flash at 1 flash per second minimum overthe Regulated Voltage Range.Notethat NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guildelines specify a flash rate of ito 3 flashes per second. •All candela ratings represent minimum effective Strobe intensity based on ULStandard 1971. •AS Series Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 320 Fto 1200 F (O C to 49 C)and maximum humidity of 93%(+2%) •AH-24 Series homs are listed underUL Standard464 foraudible signal appliances (indoor use only). •AH-24WP Series audible appliances are listed under UL Stan dard 464 for indoor/outdoor use with a temperature range of- 310 Fto i50 F(-35°Cto66”C)and maximum humidity of 95%. •“Regulated Voltage Range”is the newest terminology used by UL to identify the voltage range.Prior this change,UL used the terminology “Listed Voltage Range”. March 30,2004 DN-5566 J-i22 Wheelock N or I F I E Il®AS Series Audible Strobe Devices and AH Series Audible Devices Section:Audio/Visual Devices CS 356 AS Audible Strobe AH Audible NOTIFIER®is a Honeywell company. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate We cannot cover all specific applications ISO 9001oranticipateallrequirements.All specifications are subject to change without notice. For more information,contact NOTIFIER.Phone:(203)484-7161 FAX:(203)484-7118 ENINElN &MANllFACTllRlN N OTI Fl E R 12 Clintonville Road,Northford,Connecticut 06472 QUALITY S YSTEMS E nr IF I ED DN-5566 •03/30/04 —Page 1 of 4 A WARNING!V PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING,OR APPLYING THIS PRODUCT.FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS,AND WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND!OR OThERS. ORDERING INFORMATION SYNC WALL!AG4CY APPROVALSSTROBENON-MOUNTING MODEL WISM,VDC CEILING ———CANDELA SYNC OPTIONS* DSM MOUNT IL MEA CSFM FM BFP AS-24M0N-FR 15/30/75/110 X X 24 WALL A,B,D,EF,GH,J,NO,R,X X X X X X AS-24rVW-FW 15/30/75/110 X X 24 WALL A,B,D,E,F,GH,J,N,O,ftX X X X X X AS-241575W-FR 15(75 on Axis)X X 24 WALL A,B,D,E,F,GH,J,NO,ftX X X X X AS-121575W-FR 15(75onAxis)X X 12 WALL A,B,D,Ej,G,HJ,N,O,R,X X X X X AS-24MCC-F\N 15/30/75/95 X X 24 CEILING A,BDE,F,G,HJ,N,O,R,X X X X * ASWP-2475W-FR 75 @-31”F X X 24 WALL I X X X X X AH-24-R -X X 24 WALL/CEILING AB,D,F,G,HJ,NO,RX X X X X X AH-12-R -X X 12 WALL/CEILING A,B,D,FG,H,J,N,O,RX X X X X X AH-24WP-R -X X 24 WALL/CEILING K X X X X X AH-12-WP-R -X X 12 WALL/CEILING K X X X X X *Referto data sheet DN61 11 for Mounting Options NOTE:Due to continous development of our products,specifications and offerings are subject to change without notice in accordance with Notifier’s standard terms and conditions REVERBERANT ANECHOIC DESCRIPTION VOLUME DBA PB?UL DBA 464@IDFT.@IOFT. High 91 99 Continuous FVdium 88 95Horn Low 83 90 High 87 99 Code 3 Horn Mdium 84 95 Low 79 90 NOTES: SM Sync Module is rated for 3.0 amperes @24 VDC. DSM Sync Module is rated for 3.0 amperes per circuit.The maximum number of interconnected DSM modules is twenty (20). AS devices synchronized with SM Module single Class “B”(Style Y)circuit WITH audible silence feature. FACP I SM +SWDBE STROBE I NAC CIRCUIT —STROBE EOLR +OUT rir I ASASj AuoIBEBLE ThBLE 1:RATINGS PER UL 1971 TABLE 2:DBA RATINGS FOR 12 VDC &24 VDC SERIES ASIAH 12 &24 VDC AUDIBLEREGULATEDINPUTSTROBE VOLTAGEMODELVOLTAGE CANDELA RANGE\1DC (cd) VDC/FWR AS-24MCW 24 16.0-33.0 15/30/75/110 AS-241575W 24 16.0-33.0 15(75onaxis) AS-121575W 12 8.0-17.5 15(75onaxis) AS-24MCC 24 16.0-33.0 15/30/75/95 ASWP-2475W 24 16.0-33.0 75@-31°F SYNC MODELS/POWER SUPPLY AVERAGEINPUTMODELMEAN MOUNTINGVOLTAGENUMBERCURRENTOPTIONS(VDC)24 VDC SM-12/24-R 24 .028 W DSM-12/24-R 24 035 W WIRING DIAGRAMS AS device non-synchronized. From PRECEDING DEVICE or FACP To NEXT DEVICE or EOLR {___:} 1+ SIGNAL •EOLR VALUE DETERMINED BY FACP NAC CIRCUIrISI. Page 2 of 4 —DN-5566 03/30/04 WIRING DIAGRAMS AS and AH devices synchronized with DSM Module dual Class “A”(Style Z)circuit with NO audible silence feature. &SYNC + &SYNC— +OUT 1 +IN 1 MINUS 1 +AUDIBLE AS and AH devices synchronized with multiple DSM Modules.IpI INTERCONNECTING WIRING SHOWN. MAXIMUM OF TWENTY (20)DSM MODULES. AUDIBLE _____ NAC DSM #1 FACP CIRCUIT v BEAQSyNc+ CIRCUIT ®SYNC — AUDIBLE NAC DSM #2 CIRCUIT v ffSTROBEA NAC CIRCUIT &SYNC — AUDIBLE NAC DSM #3 CIRCUIT v STROBE A NAC CIRCUIT &SYNC— TABLE3:A\EIlOiT* NOTES: •AS/PH must be set on continuous horn tone,and connected to the SM or DSM Sync Module,to achieve synchronized temporal (Code 3) tone. ALEIBLE WLLMXNTALDBLESTftE5EMXS CBiN33MNfS1RD8EMXS 24VtCMXS AH-24 AS-241575V AS-241vD,N AS-24Tv33N-l AS-24MX AS-241vtX3-l 1575cd 15cd 3Ocd 75cd 11)zd 135cd lSScd lScd 3Ocd 75cd 95cd llScd 177cd 1)v±0.035 0.0130 0.099 0.135 0.21)0.303 0.355 0.480 01)5 0.145 0.238 0.330 0.355 0.480 (99)cIBA 24wJc 0.050 0.007 0.093 0.114 0.157 01)7 0.250 0.320 0.970 0.20 0.69 0.213 0.250 0.320 33th 0.069 0.005 0.098 0.08 0.138 01)6 0.213 0.250 0.131 0.113 0.146 0.177 0.21)0.250 1)th 0.020 0.114 0.078 0.11)0.203 0.282 0.340 0.465 0.084 0.26 0.222 0.309 0.340 0.465 (95)dEA 24vdc 0.026 0.085 0.065 0.088 0.133 0.179 0.230 0.305 0.069 0.094 0.145 0.1)5 0.230 0.305 33vdc 0.035 0.075 0.065 0.078 0.206 0134 0.130 0.230 0.068 0.083 0.114 0.145 0.1)0 0.230 1)c1c 0.014 0.138 0.070 0.111 0.201 0.279 0335 0.460 0.076 0.21 0.220 0.306 0.335 0.460 24dc 0014 0.075 0.052 0.077 0.126 0.1)9 0.220 0.295 0.056 0.084 0.138 0.1)5 0.220 0.295 33tc 0.021 0.060 0.046 0.063 0.094 0.21 0.170 0.215 0.049 0.068 0.1)2 0.132 0.170 0,215 2VC1DS t thvI AUJBLE AWBLE 2’tXDMXRS PIJJBLE 2VtCMX6S PLUBLE SITDBE S1R38E P1-1-2 PS 21575W P1-1-2 S-21575 P1-1-2 AS-2’1575A 8th 0.093 0.320 8wJc 0.037 0.275 8dc 0.030 0.265 2do 0.049 0.1)5 2th 0,035 0.175‘Eij)2±008 0 IVE]Uvl LO(90) (95)dB dB 17.5dc 0.28 0.220 175dc 0.069 0.1)0 17.5dc 0.042 0.133 *Average RSM Current is per UL average method and Average Mean Current is per UL average mean method.AH and AS-i 2 models use average mean current.For rated in Rush and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS (FWR),see installation instructions. rmhccea •n,nIn4 —.f a WARNIN,,CONTACT WHEELOCK FOR “INSTALLATION INSTRUCTIONS”(Wheelock #P83509 [AS],#P83641 -[AH-WP],and #P83519[AH])AND “GENERAL INFORMATION”SHEET(Wheelock#P82380)ON THESE PRODUCTS.THESE MATERIALS UNDERGO PERIODIC CHANGES.IT IS IMPORTANT THATYOU HAVE CURRENT INFORMATION ON THESE PRODUCTS.THESE MATERIALS CONTAIN IMPORTANTINFORMATION THATSHOULD BE READ PRIORTO SPECIFYING OR INSTALLING THESE PRODUCTS,INCLUDING: •TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. •FUSE RATINGS ON NAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. •COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON’S FIELD OF VIEW. •VOLTAGEAPPLIED:THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. •INSTALLATION OF 100/110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. •INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. •Note:USEASIAH ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE.DO NOT USEAS SERIES ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF,AS THE STROBE MAY NOT FLASH. •CONDUCTOR SPECIFICATIONS:CONDUCTOR SIZE (AWG),LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS,PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION,APPLICATION,ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TOYOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified,applied,installed,operated, maintained,and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local,state,and federal codes,regulations,and laws.Specification,application,installation, operation,maintenance,and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA),Underwriters’Laboratories (UL),National Electrical Code (NEC),Occupational Safety and Health Administration (OSHA),local,state,county,province,district,federal,and other applicable building and fire standards, guidelines,regulations,laws,and codes including,but not limited to,all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS’&ENGINEERS’SPECIFICATIONS •The notification appliances shall be Wheelock’s patented AS Series Audible Strobe and AH Series Audible Horn devices,and when synchronization is required,companion SM and DSM Sync Modules,or approved equivalents.AS Series devices and SM and DSM Sync Modules shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service). AH Series Audible Horn shall be listed under Standard 464 (Fire Protective Signaling).AS,AH,SM,and DSM devices shall be certified to meet FCC Part 15,Class B. •The devices shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3)tone when constant voltage from a Notification Appliance Circuit (NACs)of the Fire Alarm Control Panel (FACP)is applied;or synchronized temporal (Code 3)horn and synchronized strobe when used in conjunction with the SM or DSM Sync Modules. •The AS Series shall be designed so that the audible signal may be silenced while maintaining strobe activation (when used with the SM or DSM Sync Modules).The SM and DSM Sync Modules shall incorporate two inputs from Notification Appliance Circuits (NACs) for power connection from the Fire Alarm Control Panel (FACP):one for the strobe circuit (NAC),and one for the audible circuit (NAC). A single two-wire output shall control both the audible and visual appliances.Upon activation of the audible silence function of the FACP,the audible signal shall be silenced while maintaining strobe activation. •Sound output at 10 feet (3.048 m)shall be field-selectable for 90,95,or 99 dBA anechoic for both continuous or temporal (Code 3) tone.The AS Series shall provide listed strobe intensities of 15,15/75,30,75,and 110 candela for wall-mount and/or 75 or 100 candela for ceiling-mount applications;with a flash rate of one flash per second minimum across the listed voltage range.The strobe shall incorporate a Xenon®flashtube enclosed in a rugged LEXAN®lens.The maximum allowable current at 24 VDC shall be 87 mA @ 15 cd,102 mA @ 15/75 cd,120 mA @ 30 cd,177 mA @ 75 cd,and 202 mA @ 110 cd.All devices shall incorporate a reduced inrush circuit design.The strobe shall have a horizontal plane. •The Sync Module shall be designed and available in two versions:the SM-I 2/24,for control of a single Class “B”NAC circuit;and a dual-output version,the DSM-12124,for control of either a single Class “A”or two Class B”NAC circuits.The DSM dual-circuit version shall provide the additional capability of daisy-chaining,”i.e.,the ability to interconnect multiple DSM’s for synchronous horn and strobe operation on multiple NAC circuits.DSM-12/24 interconnection capability shall be for a maximum of 20 modules (40 Class “B”NAC circuits or 20 Class “A”NAC circuits).Rated average current requirement for the SM-12124 shall be 0.014 amperes @ 12 VDC and 0.025 amperes @24 VDC;the DSM-12/24 shall be 0.020 amperes @ 12 VDC and 0.038 amperes @24 VDC.The SM Sync Module shall be capable of handling a three-ampere load at 12 or 24 VDC.The DSM Sync Modules shall be capable of handling a load of three amperes per circuit in the Class “B”mode,and three amperes per module in the Class “A”mode at 12 or 24 VDC. •SM or DSM Sync Modules and AS Audible Strobes shall be designed as a system for continuous activation of the strobes should the Sync Module contacts fail in the passive state (i.e.,contacts remain closed).In this default mode,the strobes shall revert to a non- synchronized default flash rate. •AS/AH Series devices shall be designed for operation at 12 or 24 VDC,over their respective listed voltage ranges of 10.5 to 15 6 VDC;and 20.0 to 31.0 VDC.The units shall be designed for operation on filtered DC,or unfiltered VRMs.Rated average current for AS Series devices shall depend upon voltage and strobe intensity;current shall be as low as 0.058 amperes for 24 VDC versions and 0.145 amperes for 12 VDC versions.Rated average current for AH Series devices (volume set at high-dB output)shall be 0.041 amperes for 24 VDC versions and 0.113 amperes for 12 VDC versions. •All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of size #18 AWG (0.75mm2)to #12 AWG (3.25 mm2). •AS/AH shall incorporate a patented Universal Mounting Plate which shall allow mounting to single-gang,double-gang,4”(10.16 cm) square,100 mm European backboxes or Wheelock’s SHBB surface backbox.No additional trim plate shall be required for flush mounting. •Dimensions for AS/AH appliances shall be 4.625”(11.7475 cm)square by 1 5”(3.81 cm)deep. Page 4 of 4 —DN-5566 •03/30/04