Loading...
HomeMy WebLinkAboutPERMIT Stairs 1010 S Saint Vrain Ave A6 2010-10-05Received Date o f stes rk ,P111 , Permit Number 1,14- Received By Aii lic d to for scell eous er it Application Expir Department of Building Safety 170 MacGregor Avenue P.O. Box 1200 Estes Park, C 1 80517 General Information & Inspection Line (970) 577-3731 ° FAX (970) 586-0249 * ,esj elect, Job Address: /0 /0 S Owner Name: 70/0 eS S77 �— (Street) Contractor/Applican b:7-s771c-,A (City) Permit Expires Phone: 3,7- eo (State) ij R'Z' 57 (Zip Code) c c,— (CCJeee,,,,J_X-HC • Town License #://5-3 Phone: (9-14-i- 300 1frr - I-37s /2,-e c' Street 0 Long-term Residential (? 30 days) (City) State) (Zip Code) hort-term Residential (< 30 days DICommercial El Replace Furnace 0 Replace Boiler El Replace Hot Water Heater El Minor Plumbing 0 Minor Remodel El Gas Line ( ft.) El Replace Windows o Install Air Conditioning 0 Temporary Structure Use 1. r Time Period '3 - r 0 Fireplace Insert - circle one: Gas, Wood, Pellet; IXOther Description of Work: Valuation (Total Cost of Material & Labor): $ le P ace ao. I certify this application is true and correct and agree to perfomi the work described according to plans/specifications submitted, reviewed and approved, and comply with local ordinances, state and federal laws as well as building codes. I certify that I have the property owner's authority and permission to apply for this permit. Additionally, I UNDERSTAND THAT I AM RESPONSIBLE FOR ANY FEES OR EXPENSES INCURRED FOR PLAN REVIEW, PERMITS, INSPECTIONS AND OTHER FEES ASSOCIATED W1TTfflSAPPL1CAT1ON. Note: The work authorized by this permit requires the building be provided with smoke alarms complying with municipal cod Si Inspection Checklist: 0 Address Posted 0 Contractors Licensed 0 Permit Packet Available 0 Safe Access Comments: gro Date/ &Print Name *** 0 Equipment Access 0 Equipment Listed 0 Equipment Clearances 0 Pan and Drain Ice Use Only *** OT&P 0 Gas Pipe 0 Vent 0 Combustion Air Permit Fee: 0 Smoke Detectors 0 Rough Inspection 0 Final Inspection County Tax: Total: (QC) ' 'iNse r o rnm _ di rya\ u n11 \ ( the Counter Page 1 of 1 Revised 6/13/2006 CB Stair & Handrail Specifications New or existing light required -Y' Guardrail 36" min. height Less than 6" dia. Open guardrails on decks more than 30 inches above grade or a floor below shall have members spaced so that a 4 Inch diameter sphere cannot pass through. Openings for required guards on the sides of stair treads shall not allow a 4 3/8" diameter sphere to pass through. Open risers less than 4' 7 3/4" max. rise 34-38" above nos ngs BtlPdWp�'ni�Vrib� Stalrway Notes: 1. Stairways shall be not less than 36" in width. 2. Stairway rises shall be not greater than 7 3/4". 3. Stairway treads shall have a minimum run of 10". 4. The length of Run and the height of Riser shall not vary more than 3/8" in the entire run of the stair. 5. Stairs are required to be illuminated. 6. Open risers permitted if opening is less than 4". 7. A nosing not less than 3/4 but not more than 1 1/4" shall be provided on stairways with solid risers, and less than 11". Handrail (see details below) 36" Min. Landing same width as stairs Finished grade Handrail Notes: 1. Handrails shall be continuous on at least one side of stairs with 4 or more risers. 2. Top of the handrails shall be placed not less than 34 inches nor more than 38 Inches above stair nosings. 3. The handgrip portion of handrails shall be not less than 1-1/4 Inches nor more,than 21/4 inches In circular cross section. 4. Handrails shali be placed not less than 1-1/2 Inches from any wall or other surface. 5. Handrails to be returned to wail, post or salty terminal (per 311.5.6.2 IBC) Acceptable I-landrail Details 'Aa" - 2'/4" max. 1 a/a" - 2" Gripable ■'..— Wall or other surface 1 '/2" min. 1-'/2" min. This handout was developed by the Colorado Chapter of the international Code Council as a basic plan submittal under the 2003 Internalfonai Residential Code. It is not intended to cover at circumstances, Check with your Department of Building Safely for additional requirements.. Unacceptable Handrails TOWN OF ESTES PARK P.O. BOX 1200, ESTES PARK, CO 80517 3 -9r •n 9L .ee.s4 eg .00 e s =emu to 0 0 0 IN 0 00'LB 30.912y00,09 9 0 . 1 110N3909"03 900 9319030 31190d I 001 30tld 9,90 )1 1,34351/.D g4)¢V7 .00 Y OE. I+0 15 . 6637 N einoa O,vU,tl' UUE'I;�. ,N•� J IDID.Q���b &` M3 197110313,I 03 lvb?N39 •'93'9 avow an eawu 0.6 ca INualAw'I Ammo. N,11':tl6"Yp')090.p ntla YP dV 0.N Y'WM,V I'. au N '',d" N 0 • • O S n )Rl`wr '✓'IINAWJ !!,ZakMace U`Po uR is ^Iiiil'n aia ip ,aLaaa Date Requested C 0 /0 0 � 0 . /OS Date Inspected Z O! 0 d/ 0, 0 Inspector TOWN OF ESTES PARK Building Division INSPECTION RECORD 44, JOB ADDRESS /(9/0 �� i ma's Zovey4/4,- _C S., y A-iN iivg REQUESTED BY �fi?JGK tJ g / ("ReEK /nN'-17-; CONTACT INFO. 970- 2 fq= 3000 TOWN LIC. # TYPE OF INSPECTIONS 5rif-r2-S OA /ge rg ' , ,e 7if-r2S WORK SHALL NOT PROCEED UNTIL APPROVED When corrections have been made, call for re -inspection: 970-577-3731. General questions: call 970-577-3735. $100.00 Re -Inspection Fee Assessed 0 Date Requested 41/10 0 /0 /05-0 Per it # Date Inspected 4/4 T JOB ADDRESS /0/ REQUESTED BY eliv Inspector T Building Div sion b CONTACT INFO. 970 2--/ 3000 TYPE OF INSPECTIONS ST2V4S A TOWN LIC. /6-.e & z/ s 77f7/2s 12,10#10 V h WORK SHALL NOT PROCEED UNTIL APPROVED When corrections have been made, call for re -inspection: 970-577-3731. General questions: call 970-577-3735. $100.00 Re -Inspection Fee Assessed E1 RIESEEDENTIAL IPLEIREDlIT liN I ECT fON RECORD JOB ADDS SS....... O I Q _... OCCUPANCY GROUP 4 ) OWER . DESCRIPTION OF WORE ._-..W..__CHST. TYPE / OCCUPANCY LOAD / SPRINKLER __COCTOR U4.4a r TIS CARD MUST ;E POSTED AND VIIS [I LIB FROM TEE FRONT OF JO PLASTIC OR OMER WATERPROOF MAT1 LAL $ETBACKS FOOTING r5 PHONE 0 `f 3 o SITE AND MUST BE PROTECTED. ROTECTI MTHH UFFER GROUND UNDATiON DRAIN P:r, E / RADON