Loading...
HomeMy WebLinkAboutPLANS MECHANICAL Pavillion 250 Steamer Pkwy 2017-07-01T S PLUMBING LEGEND: V G F G RADE CLEANOUT RD ORD W GW HWC HW TW CW CD PIPE ELBOW UP PIPE TEE DOWN PIPE TEE UP HOT WATER CIRC. TEMPERED WATER NATURAL GAS PIPING PIPE ELBOW DOWN WASTE PIPING VENT PIPING HOT WATER PIPING COLD WATER PIPING PIPE CONTINUATION RO OF DRAIN PIPE OVERFLOW RD PIPE SOLENOID VALVE PIPE CAP UN ION CHECK VALVE BALANCE VALVE PR ESS. RED. VALVE G ATE VALVE G AS COCK BALL VALVE FLOOR CLEANOUT WALL CLEANOUT RO OF DRAIN GREASE WASTE PIPING INVERT ELEVATIONI.E. NE W(N) X SHT # DETAIL X SHEET # 101 REFERENCE DETAIL OR ISOMETRIC FIRE PIPING T & P RELIEF VALVE CONDEN SATE PIPING MECHANICAL DRAWING INDEX SHEET SHEET NAMENUMBER SHEET SHEET NAMENUMBER HVAC LEGEND: RTU-X RTU-X CO2 ROUND DUCT (NEW SHADED/EXISTING UNSHADED) RECT TAKE-OFF W/ DAMPER FROM ROUND MAIN RECT TAKE-OFF W/ DAMPER FROM RECT MAIN ROUND TAKE-OFF W/ DAMPER FROM ROUND MAIN ROUND TAKE-OFF W/ DAMPER FROM RECT MAIN DUCT WITH MOTORIZED DAMPER DUCT WITH COUN TERBALANCED DAMPER RETURN/EXHAUST GRILLE (DUCTED) AIRFLOW PATTERNS THERMOSTAT WITH ZON E TAG FIRE DAMPER TAG FIRE/SMOKE DAMPER WITH DUCT DETECTOR DUCT WITH VOLUME DAMPER RETURN GRILLE (UN DUCTED) DIFFUSER WITH FLEX DUCT F FS RECT DUCT SIZE CHANGE RECT DUCT CHAN GE TO ROUND RECT ELBOW UP (SUPPLY) RECT ELBOW UP (NON-SUPPLY) RECT ELBOW DOWN (SUPPLY) RECT ELBOW DOWN (NON-SUPPLY) ROUND ELBOW DOWN ROUND ELBOW UP ROUND ELBOW RECT ELBOW W/ TURN ING VAN ES RECT DUCT (NEW SHADED/EXISTING UNSHADED) SENSOR WITH ZONE TAG SMOKE DAMPER WITH DUCT DETECTORSD CARBON DIOXIDE SENSOR GENERAL MECHANICAL REQUIREMENTS: CODES AND PERMITS WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES, R EGULATIO NS AN D ORDINANCES. PERMITS NECESSARY FOR PERFORMANCE OF WOR K SHALL BE SECURED AND PAID FOR BY THE CONTR ACTOR . DRAWINGS AND COORDINATION DRAWINGS FOR MECHANICAL WORK ARE DIAGRA MMATIC IN NATURE, AND ARE NOT INTENDED TO BE SCALED FOR EXACT MEASUR EMENTS NOR TO SE RVE AS SHOP DRAWINGS. CHANG ES FROM THE P LANS MAD E WITHOUT CONSENT OF THE ENGINEER SHALL RELIEVE THE ENGIN EER O F R ESPONSIBILITY FOR ALL CONSEQUENCES ARRIVING OUT OF SUCH CHANGES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER 'S INSTALLATION IN STRUCTIONS. WHERE CON DITIONS REQUIRE REASONABLE CHANGES TO THOSE IN DICATED ON THE DR AWINGS, MAKE SUCH CHANG ES WITHOUT ADDITIONAL COST TO THE OWNER. CO ORDIN ATE ALL WORK WITH OTHER TRADES. WARRANTY WORK MANSHIP, MATERIALS, EQUIPMENT AND PROPER O PERATION SHALL BE G UARANTEED FOR A PERIOD OF ON E YEAR FROM THE DATE OF FINAL ACCEPTANCE FROM THE OWNER. INITIAL ACCEPTANCE OF WORK SHALL N OT WAIVE THIS GUARANTEE. THIS G UARANTEE SHALL NOT INCLUDE NORMAL MAINTENANCE REQUIRED BY THE OWNER AS DESCRIBED IN EQUIPMENT OPERATION AND MAINTENANCE MANUALS. SUBMITTALS CON TRACTO R SHALL SUBMIT TO THE ARCHITECT/ENG INEER A MINIMUM OF (5) COPIES OF SUBMITTAL BROCHURES FOR REVIEW. PROVIDE IN FORMATION ON ALL MAJOR EQUIPMENT AS LISTED ON DRAWIN G EQUIPMEN T SCHEDULES, AS WELL AS VALVES, DUCTWO RK ACCESSOR IES AN D TEMPERATURE CONTROL DIAGRAMS AS APPLICABLE. OPERATION AN D MAINTENANCE MANUALS CON TRACTO R SHALL FURNISH AT THE COMPLETION OF THE PROJECT (2) COPIES OF COMPLETE OPERATIO N AN D MAINTENANCE MANUALS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO TURN OVER TO OWNER. MAN UALS TO BE BOUND AND INCLUDE INSTALLATION INSTRUCTIONS, REPLACEMEN T PARTS LISTS AND MAINTENANCE INFORMATIO N ON ALL EQUIPMENT AS DESCRIBED IN THE SUBMITTALS SECTION. COMPLETED OPERATION AND MAINTENANCE MANUALS ARE TO BE FORWARDED TO THE OWNE R WITHIN 90 DAYS AFTER OWNER BUILDIN G ACCEPTANCE. PRODUCT SUBSTITUTIONS MANUFACTURE R MODEL NUMBERS LISTED ON THE DRAWING S AND/OR SPECIFICATIONS ARE TO BE CONSIDERED AS THE BASIS OF DESIGN. WHERE TWO OR MORE ALTERNATE MANUFACTURERS OR MATERIALS ARE LISTED, THE CHO ICE OF THESE SHA LL BE OPTIO NAL WITH THE CONTRACTOR. PRIOR TO THE AWARDING OF THE CO NTRACT, CON TRACTO R MAY REQ UEST A PROPOSED SUBSTITUTION OF MATERIALS IN WRITING TO THE ARCHITECT/ENGINEER NO LATER THAN SEVEN DAYS PRIOR TO THE RECEIPT OF BIDS. THE COST OF AN Y CHAN GES REQUIRED BY OTHER TRADES, INCLUDING A/E DESIGN, DUE TO THE USE OF EQUIPMENT AND /OR MATERIALS OTHER THAN THAT OF THE BASIS OF DESIGN SHALL BE PAID BY THE CON TRACTO R. RECORD DRAWINGS CON TRACTO RS SHALL MAINTAIN A CO MP LETE AND ACCURATE SET OF MARKED UP DRAWINGS SHOWING ACTUAL LOCATION S OF IN STALLED WORK. THESE DR AWINGS ARE TO BE FORWARDED TO THE OWNER AS PART OF THE OPERATIO N AN D MAINTENANCE MANUALS AT THE COMPLETION OF THE PROJECT. ACCESS DOORS PROVIDE ALL ACCESS DOORS/P ANELS AS REQUIRED FOR ACCESS TO VALVES, DAMPERS, CONTROL DEVICES, FILTERS AND ANY OTHER ITEMS FOR WHICH ACCESS IS REQUIRED FOR EITHER O PERATION OR SERVICIN G. WHERE ACCESS DOORS ARE TO BE IN STALLE D IN ASSEMBLIES REQUIRED TO HAVE A SPECIFIC FIRE RATING , ACCE SS DOORS SHALL ALSO BE FIRE RATED. PIPIN G AND DUCTWORK SEALAN T THROUG H RATED ASSEMBLIES PEN ETRATIONS SHALL BE SEALED AS REQUIRED IN ACCORDANCE WITH BUILDIN G AND MECHANICAL CODES TO RESIST THE P ASSAG E OF FLAME AND PR ODUCTS O F COMBUSTION IN ORDER TO MAINTAIN THE RESISTANCE RATING OF THE CON STR UCTION BEING PENETRATED. PROTECTION OF MATERIALS AND EQ UIPMENT CON TRACTO R SHALL BE R ESPONSIBLE FOR PROTECTION OF ALL WORK, MATERALS, AND EQUIP MENT PROVIDED UNDER THIS SECTION. PIPE OPENINGS SHALL BE CLOSED WITH CAPS OR P LUGS TO PREVEN T THE ENTRANCE OF DEBRIS DURING CONSTRUCTION. ALL DUCTWORK OPEN INGS SHALL BE SEALED CLOSED DURING C ONSTRUCTION . EQUIPMENT AND PIPING IDENTIFICATION PROVIDE EQUIPMENT LABELS FOR ALL MAJOR EQUIPMENT, INCLUDING BUT NOT LIMITED TO AIR HANDLING SYSTEMS, FANS, VAV B OXES, CON TROLS, DAMPERS, CONTROL VALVES AND PUMPS. PROVIDE PIPE MARK ERS ON CW, HW AND HWC SYSTEMS. LAB ELS TO BE AT MAXIMUM 8 FEET APART, WITH FLOW DIRECTION IN DICATED, AS APPLICABLE. ADDITIONALLY, PROVIDE LABELING ON POTABLE WATER MAN IFOLDS INDICATING PLUMBING FIXTURE SERVED BY THE OUTLET, AS APPLICABLE. LABELS SHALL BE AFFIXED OR ADHERED PERMANENTLY TO EQUIPMENT. EQUIPMENT INSTALLED INDOORS TO B E LABELED WITH EMBOSSING TAPE. EQUIPMENT INSTALLED OUTDOORS TO BE LABELED WITH ENG RAVED PLASTIC LAMINATE SIG N S. PIPE MARKERS TO BE SELF-ADHESIVE, MANUFACTURED FOR SUCH P URPOSE. STARTERS AND DISCONN ECTS EQUIPMENT STAR TERS SHALL BE FURNISHED BY THE MECHANICAL CON TRACTOR AND INSTALLED BY THE ELECTRICAL CON TRACTO R. EQUIP MENT DISCONNECTS SHALL BE PRO VIDED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE ON THE DRAWIN GS. STARTERS SHALL BE NEMA TYPE, AND SHALL IN CLUDE PHASE MON ITORING FOR MOTORS 5 HP AND LARGER. TESTING TESTING SHALL BE PERFORMED ON THE FOLLO WING SYSTEMS SPECIFIED. ALL SYSTEMS LISTED MAY NOT BE INCLUDED IN PROJECT, REFER TO D RAWIN GS FOR APPLICABLE SYSTEMS. SOIL, WASTE AND STORM DRAINAGE PIPIN G SHALL BE TESTED IN ACCORDANCE WITH APPLICABLE STATE AND LOCAL CODES. DOMESTIC WATER PIPING SHALL BE TESTED AND PROVEN WATERTIGHT UNDER A PR ESSURE NOT LESS THAN THE WORK ING PRESSUR E OF THE SYSTEM FOR A 24 HO UR PERIOD. DOMESTIC WATER PIPING SYSTEM SHALL BE CHLORINATED AND STER ILIZED IN ACCORDANCE WITH REQUIREMENTS O F LOCAL JURISDICTION. NATURAL GAS PIPING SHALL BE TESTED WITH AN AIR PRESSURE O F MINIMUM TWO TIMES THE DESIGN SYSTEM PRESSURE, BUT NO LESS THAN 3 PSIG, FO R A PERIOD OF 24 HOURS WITHOUT PRESSURE DROP. BALANCIN G SYSTEM BALANCIN G SHALL BE PERFORMED BY A CERTIFIED BALANCING CON TRACTOR. BALANCE ALL SYSTEMS INCLUDIN G AIRFLOW TO AN D FRO M ALL O PENINGS, AND PUMPED WATER SYSTEMS INCLUDIN G DOMESTIC WATER RECIRCULATION SYSTEMS AS APPLICABLE. MAK E ANY ADJUSTMEN TS NECESSARY TO RESULT IN CONDITIONS IN DICATED AND PROVID E READJUSTMENTS TO ITEMS IN REPORT AS MAY BE REQUESTED BY ARCHITECT/ENG INEER. SUBMIT TWO COPIES O F TEST AND B ALANCE REPORT FOR APPROVAL. FAN AN D PUMP SYSTEMS TO BE BALAN CED WITHIN PLUS OR MINUS 5 PERCENT OF LISTED VALUES. AIR INLETS AND OUTLETS TO BE BALANCED WITHIN PLUS 10 PERCENT OR MINUS 5 PERCENT OF LISTED VALUES. BALANCE REPORT TO IN CLUDE: UNIT IDENTIFICATION MANUFACTURER AND N AMEPLATE DATA EQUIPMENT NAMEPLATE AMPERAGE AND ACTUAL AMPERAGE RPM (DESIG N AND ACTUAL) FAN CFM (DESIGN AND ACTUAL) FAN STATIC PRESSURE (DESIGN AND ACTUAL) PUMP GPM (DESIGN AND ACTUAL) PUMP DISCHARGE AND SUCTION PRESSURE REG ISTER, G RILLE, DIFFUSER REFERENCE NUMBER AND LO CATION INLET/OUTLET CFM (DESIGN AND ACTUAL) FLOW DEVICE PRESSURE DROP, CFM OR GPM A FINAL BALANCIN G REPORT SHALL BE PROVID ED TO THE OWNER AFTER COMPLE TION OF THE PROJECT. CLEANING AT THE COMPLETION OF WORK, ALL FIXTURES AND EQUIPMENT SHALL BE THOROUGHLY CLEANED AN D DELIVERED IN A CON DITION SATISFACTORY TO THE ARCHITECT. ALL FILTERS SHALL BE REPLACED WITH NEW PRIOR TO OWNER ACCEPTANCE OF THE BUILDING. Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 MP0.1 ME C H A N I C A L G E N E R A L NO T E S , L E G E N D S A N D DR A W I N G I N D E X JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 P1.0 WASTE AND VENT BASEMENT FLOOR PLAN P1.1 SUB-SURFACE DRAINAGE PLAN P2.0 WATER AND GAS BASEMENT FLOOR PLAN P3.1 PLUMBING FIRST FLOOR PLAN P3.2 PLUMBING SECOND FLOOR PLAN P3.3 PLUMBING ROOF PLAN P4.1 WASTE AND VENT ISOMETRICS P5.1 WATER AND GAS ENLARGED FIRST FLOOR PLAN P6.1 PLUMBING SCHEDULES AND DETAILS P6.2 GREASE PUMP SYSTEM SCHEDULES AND DETAILS P6.3 SNOW MELT SCHEDULES AND DETAILS MP0.1 MECHANICAL GENERAL NOTES, LEGENDS AND DRAWING INDEX M2.0 HVAC BASEMENT FLOOR PLAN M2.1 HVAC FIRST FLOOR PLAN M2.2 HVAC SECOND FLOOR PLAN M2.3 HVAC ROOF PLAN M3.1 ENLARGED MECHANICAL ROOM PLAN M4.1 MECHANICAL ROOM ISOMETRIC #1 M7.1 HVAC DETAILS M8.1 HVAC SCHEDULES GENERAL PLUMBING NOTES: PLUMBING WORK SHALL COMPLY WITH ALL APPLICA BLE CODES. VERIFY ALL REQUIR EMENTS PRIOR TO SUBMITTING BID OR COMMENCING WORK. THE PLUMBING DESIGN IS BASED ON THE 2012 INTERNATIONAL PLUMBIN G CODE. 1. WASTE AN D VENT PIPING BELOW SLAB SHALL BE SCHEDULE 40, DWV, PVC, PLASTIC. FITTING S SHALL BE PVC. 2. WASTE AN D VENT PIPING ABOVE SLAB SHALL BE SCHEDULE 40, DWV, PVC, PLASTIC. FITTIN G S SHALL BE PVC. 3. 4.ROOF DRAIN PIPING BELOW SLAB SHALL BE SCHEDULE 40, DWV, PVC, PLASTIC. FITTIN G S SHALL BE PVC. 5.ROOF DRAIN PIPING ABOVE SLAB SHALL BE SCHEDULE 40, DWV, PVC, PLASTIC. FITTIN G S SHALL BE PVC. 6. 7. POTABLE WATER PIPING BELOW GRADE SHALL BE TYPE K COPPER WITHOUT JOINTS. 8. POTABLE WATER PIPING ABOVE GRADE SHALL BE TYPE L COPPER WITH SOLDERED COPPER FITTING S AND NO LEAD SOLDER UN LESS NOTED OTHERWISE. 9. POTABLE WATER BRANCH PIPING 1" AN D SMALLER MAY BE PEX TUBING MANUFACTURED BY UP ONOR/WIRSBO OR APPROVED EQUAL AT CONTRAC TOR 'S OPTION. 10. POTABLE WATER VALVES SHALL BE FULL PORT, BALL TYPE. 11. HANGERS FOR 2" AND SMALLER PIPE SHALL BE BAN D TYPE, 2.5" AN D LARGER SHALL BE CLEVIS TYPE. USE CO PPER COATED TYP E ON COPPER PIPE. 12. G AS P IPE 2.5" AND SMALLER SHALL BE SCHEDULE 40 BLACK STEEL. FITTINGS SHALL BE MALLE ABLE SCREW TYPE. 13. GAS PIPE 3" AND LARGER SHALL BE SCHEDULE 40 B LACK STEEL. FITTINGS SHALL BE FULLY WELDED . 14. 15. 16. IN STALL UNIO N, G AS COCK AND FULL SIZE 6" LONG D IR T LEG FOR ALL GAS FIRED EQUIPMENT. 17. IN STALL FULL SIZE CONDEN SATE AND TRAP FOR ALL COOLIN G COILS. DISCHARGE FULL SIZE DRAIN TO MOP SINK OR LAVATORY P-TRAP TAILPIECE AND TO ROOF FOR ROOFTOP UN ITS. 18. FURNISH AND INSTALL WATTS 9D-M2 0.75" BACKFLOW PREVEN TION DEVICE FOR ICE MACHINES. INSTALL 0.75" DRAIN AND TERMIN ATE TO FLOOR SINK WITH FULL AIR G AP. 19. FURNISH AND INSTALL WATTS SD-3 LEAD FREE D UAL CHECK BACKFLOW PREVENTION DEVICE WITH AIR GAP FOR CARBONATOR AND SODA SYSTEM. FURNISH AND INSTALL WATTS SD-3 LEAD FREE D UAL CHECK BACKFLOW PREVENTION DEVICE WITH AIR GAP FOR COFFEE URN AND TEA DISPENSERS. REFERENCE KITCHEN DRAWINGS FOR PLUMBING REQUIREMENTS. PERIMETER DRAIN P IPIN G SHALL BE PERFORATED ADS PIPE WITH FILTER SOCK. PIPING SHALL BE EMBEDDED IN FREE-DRAININ G G RAVEL PLACED IN A TRENCH AT LEAST 12 INCHES IN WID TH. G RAVEL SHALL EXTEND A MIN IMUM OF 3 IN CHES BEN EATH THE BOTTOM OF THE P IPE, AND AT LEAST 2 FEET ABO VE THE BOTTOM OF THE FOUNDATIO N WALL. THE SYSTEM SHALL BE UNDERLAIN WITH A POLYETHYLENE MOISTURE BARRIER, SEALED TO THE FOUNDATION WALLS, AN D EXTEND IN G AT LEAST TO THE EDG E OF THE BACKFILL ZON E. THE GRAVEL SHALL BE COVERED WITH DRAIN AGE FABRIC PRIOR TO PLACEMENT OF FOUNDATION BACKFILL. PC SHALL COOR DINATE THIS REQUIREMENT WITH GENERAL CONTRACTOR FOR INSTALLATION BY O THERS. GENERAL HVAC NOTES: MECHANICAL WORK SHALL COMPLY WITH ALL APP LICABLE CO DES. VERIFY ALL REQUIREMENTS P RIOR TO SUBMITTIN G B ID OR COMMEN CING WORK. THE MECHANICAL DESIGN IS BASED ON THE 2012 INTERNATIONAL MECHANICAL CO DE. 1. 2.ALL DUCTWORK SHALL BE C ONSTRUCTED OF GALVANIZED SHEET METAL - CONSTRUCTION AN D INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF SMACNA OR AS REQUIRED BY ALL APPLICABLE CODES. 3.CON STR UCT ALL AHU-1 AND RTU-1 SUPPLY AND RETURN DUCTWORK TO SMACNA 2" PR ESSURE CLASS. 5.CON STR UCT ALL EXHAUST D UCTWORK TO SMACN A 1" PRESSURE CLASS. 6.DIMENSION S OF DUCTWOR K SHOWN INDICATES CLEAR INSIDE DIMENSION S - WHERE DUCT LINER IS TO BE ADDED, INCREASE THE SIZE OF SHEET METAL ACCORDING LY. 7.UNLESS N OTED OTHERWISE, THE SIZE OF THE BRANCH DUCT SERVING A SIN GLE DIFFUSER SHALL BE THE SAME AS THE NECK SIZE OF THE DIFFUSER SER VED . FLEXIBLE DUCTWORK SHALL N OT EXCEED 8'-0" IN LENGTH. FLEXIBLE DUCTWO RK SHALL BE UL181 LISTED WITH 50/25 SMOKE/FLAME RATING , CONSISTING OF POLYESTER FILM ENCAPSULATING AN INNER CORR OSION RESISTANT STEEL WIR E HELIX CORE. FLEXIBLE DUCT SHALL INCLUDE AN EXTERIOR FIBERGLASS INSULATION WITH FOIL SCRIM FILM VAPOR BARRIER JACKET, R-6. 8.MAINTAIN A MINIMUM 10'-0" SEPARATION FR OM OUTSIDE AIR INTAKES TO EXHAUST TERMINATIONS AND PLUMBING VENTS. 9.MAINTAIN A MINIMUM 3'-0" SEPARATION FROM EXHAUST TERMINATIONS TO OPERABLE WINDOWS AND DOORS. 10.WALL MO UN TED THERMOSTATS AND SEN SO RS SHALL BE INSTALLED 48" ABOVE FINISHED FLOOR UNLESS N OTED OTHER WISE. THER MOSTATS AND SEN SORS LO CATED ON EXTERIOR WALL SURFACES SHA LL BE PROVIDED WITH AN INSULATED SUB-BASE. 11.TEMPORAR Y HEATING: THE PERMANENT HVAC SYSTEM MAY NOT BE UTILIZED FOR HEATING UNTIL ALL GYPSUM WORK IS COMPLETED AND HAS BEEN PAINTED. IF THE PERMANENT HVAC SYSTEM IS UTILIZED DURING CONSTRUCTION, ALL DUCT INTAKES SHALL B E COVERED WITH FILTER MEDIA (MERV-8 RATING). IF EXCESSIVE DUST OR DEBRIS HAS ENTERED THE SYSTEM THEN ALL COIL AND DUCT SURFACES SHA LL BE CLEANED. NEW FILTERS ARE TO BE PROVIDED JUST PRIOR TO TURNOVER TO OWNER. TEMPORARY HEATING OF THE BUILDING PRIOR TO ANY USE OF THE PERMANENT HVAC SYSTEM SHA LL BE THE RESPONSIBILITY OF THE G.C. 12.FIRE DAMPERS SHALL BE 'B' TYPE, WITH BLADES ENTIRELY OUT OF AIRSTREAM. 4.CON STR UCT ALL AHU-2 AND AHU-3 SUPPLY DUCTWORK UPSTREAM OF ALL VAV BOXES TO SMACNA 4" PRESSURE CLASS. CONSTRUCT ALL OTHER SUPPLY DUCTWORK AND RETURN DUCTWORK TO SMACNA 2" PRESSURE CLASS. ENERGY CODE/INSULATION NOTES: THE MECHANICAL DESIG N IS BASED ON THE 2009 IN TERNATIONAL ENERGY CONSERVATION CODE. 1. ALL SUPPLY, RETURN AND EXHAUST DUCTWORK SHALL BE SEALED AIRTIG HT WITH DUCT SEALANT ALON G ALL SEAMS AND JOINTS. 2. ALL RECTANGULAR SUPPLY DUCTWORK SHALL BE LIN ED WITH 1.5", 1.5 LB DENSITY DUCT LINER , MINIMUM R-5. 3. ALL CONCEALED ROUND SUPPLY DUCTWORK SHALL BE WR APPED WITH 1.5" THICK FIBERGLASS INSULATIO N WITH FOIL SCRIM VAPOR BARRIER J ACKET, MINIMUM R-5. 4. ALL RECTANGULAR RETURN DUCTWORK SHALL BE LINED WITH 1.5", 1.5 LB DENSITY DUCT LINER , MINIMUM R-5. 5. 6. 7. 8. ALL OUTSIDE AIR DUCTWO RK SHALL BE WRAPPED WITH 2" THICK FIBERG LASS INSULATION WITH FOIL SCRIM VAPOR BARRIER JACKET, MINIMUM R-8. NO DUCT LINER ALLOWED. 9. 10. HOT WATER PIPING SHALL BE INSULATED USING FIBERGLASS INSULATION WITH ALL SERVICE JACKET HAVING MAXIMUM 'K' FACTOR OF 0.27. INSULATION THICKNESS SHALL BE 1". HOT WATER RECIRCULATION PIPING SHALL BE INSULATED FIBERGLASS INSULATION WITH ALL SERVICE JACKET HAVIN G MAXIMUM 'K' FACTOR OF 0.27. INSULATION THICKNESS SHALL BE 1". COLD WATER PIPING SHALL BE INSULATED USING FIB ERGLASS INSULATION WITH ALL SERVICE JACKET HAVING MAXIMUM 'K' FACTOR OF 0.27. INSULATION THICKNESS SHALL BE 0.5". HORIZONTAL ROOF DRAINAGE PIPING , AN D ROOF DRAIN AND OVERFLOW ROOF DRAIN B ODIES SHALL BE INSULATED USING FIBERGLASS INSULATION WITH ALL SERVICE JACKET. INSULATION THICKNESS SHALL BE 0.5". 1 1 1 2 13 FEB 2017 A B.1 C.1 1 2 3 4 5 6 7 8 9 10 11 12 H G' G E'E.5D.2DB.9B F DF-1 AHU-2 AHU-3 AHU-1 DF-2 D F-3 4 0 " x 1 4 " 40"x1 4" 28 "x 1 4 " 20"x1 2" 24 "x 1 4 " 2 4 "x 1 4 " 20"x1 2" 12"x1 2" VAV-1-2 VAV-1-1 VAV-1-3 LVR-1 LVR-2 EF-3 10"ø T EF-3 8"ø 8"ø 8 "ø 8 "ø 8 "ø 160 D-4-12x6 80 D-4-12x6 4 0 "x 1 8 " 1 1 2 2 2 2 3 3 3 4 5 2 1 4 " x 1 4 " 8"ø 6"ø 6"ø 50 R-1 50 R-1 FLAG NOTES: REFER TO EN LARG ED MECHAN ICAL ROOM PLAN ON SHEET M3.1 FOR ALL DUCTSIZES AND INSTALLATION REQUIREMENTS. ALL BRANCH DUCTWORK TO FLOOR D IFFUSER S ON SECOND FLOOR SHALL BE 10"Ø, TYP. DUCT MAIN SHALL BE INSTALLED TIG HT TO BOTTOM OF STEEL. BRANCH DUCTWORK SHALL BE ROUTED WITHIN STUCTURE. EF-3 EXPOSED WITHIN ELEVATOR MACHINE ROOM. ROUTE 10"Ø EXHAUST DUCT UP TO FIRST FLOOR. PROVIDE AND INSTALL THERMOSTAT CONTROLLER AS INDICATED. DUCTWORK UP THROUGH CHASE ON FIRST FLOOR. REFER TO ENLARGED MECHANICAL ROOM PLAN ON SHEET M3.1 FOR SIZES AND TO HVAC SECOND FLOO R PLAN FOR CONTINUATION UP, TYP . 1 2 3 4 5 GENERAL NOTES: LINEAR FLOOR DIFFUSERS ARE SHOWN ON THIS PLAN FOR REFERENCE ONLY. REFER TO HVAC FIRST FLOOR PLAN ON SHEET M2.1 FOR DIFFUSER LO CATION AND IN FORMATION . 1. Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 M2.0 HV A C B A S E M E N T FL O O R P L A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' HVAC BASEMENT FLOOR PLAN 8' 16' 13 FEB 2017 A B.1 C.1 F.1 1 2 3 4 5 6 7 8 9 10 11 12 H G' G E'E.5D.2DB.9 B F D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 D-7-1-4 360 300 R-2 300 R-2 18"x6" 18"x6" 16"x16" 52"x16" 48"x18" 64"x18" 10"ø 10"ø 16"x12" 8"ø 8"ø 1750 G-5-36x18 (2) G-6 G-6 G-1 T VAV-1-1 T VAV-1-2 T AHU-1 T RTU-1 D-1- 10"ø 300 D-1- 10"ø 300 D-1- 10"ø 300 D-1- 8"ø 200 D-1- 8"ø 200 24"x14" 1 210"ø 3 4 5 5 5 5 14 " x 1 4 " 10"ø 10"ø 10"ø D-1- 10"ø 300 D-1- 10"ø 300D-1- 10"ø 350 T VAV-1-3 1 4 "x 1 4 " 1 4 "x 1 4 " R-1 R-1 R-5-08x08 50 CFM 6 EWH-1 EWH-2 FLAG NOTES: PR OVIDE AND INSTALL (2)G-5-36x12 WITH ONE GRILLE AT 1'-0" A.F.F. AN D (1 ) G RILLE AT 1'-0" BELOW CEILING. DIMEN SIONS SHALL BE MEASURED FROM TO P OF G RILLE FOR HIGH AND BO TTOM OF G RILLE FOR LOW. 10"Ø EXHAUST DUCT UP FROM FLOOR BELOW. TERMINATE THROUGH WALL WITH WALL CAP AT MINIMUM 36" ABOVE ADJACENT GRADE. DUCTWORK DOWN WITHIN CHASE FROM SECOND FLOOR. R EFER TO HVAC SECON D FLOO R PLAN ON SHEET M2.2 FOR CONTINUATION. ALL DUCTWORK WITHIN CHASE SHALL BE IN STALLED TIG HT TO WALLS TO ACCOMMODATE FUTURE DUCTWORK INSTALLATION REQUIREMEN TS. DUCTWORK CONTIN UED FROM BASEMEN T UP TO SECOND FLOOR. RETURN G RILLE TO BE IN STALLED HIGH ON WALL OF JANITORS CLOSET. CONNECT 8"x8" EXHAUST DUCT TO EXHAUST MAIN IN VERTICAL (NOT SHOWN). 1 2 3 4 5 6 GENERAL NOTES: COO RDINATE EXACT LOCATION O F ALL FLOOR DIFFUSERS WITH ARCHITECTURAL LOCATIONS AND GC PR IOR TO INSTALLATIO N . 1. Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 M2.1 HV A C F I R S T F L O O R PL A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' HVAC FIRST FLOOR PLAN 8' 16' 13 FEB 2017 DN A B.1 C C.1 E F.1 1 2 3 4 5 6 7 8 9 10 11 12 H G' G E'E.5D.2DB.9B F D-8-2-4 360 D-8-2-4 360 D-8-2-4 360 D-8-2-4 360 75 R-3 75 R-3 75 R-3 75 R-3 75 R-3 75 R-3 3 0 "x 1 6 " 3 0 "x 1 6 " 2 4 "x 16 " 1 4 "x 14 " 2 4"x 1 6"1 6 " x 1 4 " 1 2 "ø 1 2 " ø 1 2" ø 12"ø 12"ø 36"x1 8" 12"ø 1 2 " ø 1 2 "ø 1 2 "ø 4 8 " x 1 8 " 6 4 "x 1 8 " 16"x16" 10 " ø 10 " ø 10 " ø 10 " ø 12"x12" 3 6 " x 1 8 " 20"x12" 16"x12" 320 D-2 320 D-2 70 D-3 50 D-3 50 D-3 70 D-3 70 D-3 70 D-3 34"x14" 8"ø 10"ø 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø 16"x16" 2000 R-2 2000 R-2 VAV-2-2 VAV-2-1 300 D-4-18x6 18"x6" 18"x12" 10"ø 2000 R-2 2000 R-2 T VAV-2-1 T VAV-2-1 R-1 R-1 R-1R-1 10 " x 1 0 " 14 " x 1 2 " 10"x10" 8" ø 8" ø 8"ø 8"ø D-1- 8"ø 205 D-1- 8"ø 210 D-1- 8"ø 210 D-1- 8"ø 210 VAV-2-3 G-2 G-2 12 " x 1 2 " T VAV-2-3 10"x10" R-1 24"x14" G-6 16"x16" 1 6 "x 1 6 " G-6 52 " x 1 6 " 32"x16" 32"x16" EF-2 LVR-3 EF-1 16"x16" 1 1 2 3 4 5 6"ø 12 "x12" 320 D-2 1 R-1 G-6 R-5-08x08 50 CFM 6 595 D-2-12 (TYP. OF 12 THIS ROO M) FLAG NOTES: ARCHITECTURAL VAULTED CEILING AREA. NO DUCTWORK SHALL BE INSTALLED WITHIN THIS AREA. INLINE EXHAUST FAN, EF-1, SHALL BE INSTALLED WITHIN ATTIC SPACE. PROVIDE ACCESS PANEL AS NECESSARY FOR FAN MAINTENANCE. SUPPLY AND RETURN DUCTWORK DOWN FROM RTU-1 ON ROO F. TRANSITION FROM EQUIPMENT CONNECTION TO DUCTWORK SIZES IN DICATED WITHIN VERTICAL. TERMINATE 6"Ø EXHAUST DUCTWORK UP THROUGH ROOF. PROVIDE AND INSTALL FLAT ROOF CURB WITH TERMINATE AT MINIMUM 3'-0" ABOVE ROO F. DUCTWOR K DOWN WITHIN CHASE TO FIRST FLO OR CEILING SPACE. REFER TO HVAC FIRST FLOOR PLAN ON SHEET M2.1 FOR CONTINUATION. RETURN GRILLE TO BE INSTALLED HIGH ON WALL OF JANITORS CLOSET. CONNECT 8"x8" EXHAUST DUCT TO EXHAUST MAIN IN VERTICAL (NOT SHOWN). 1 2 3 4 5 6 1 GENERAL NOTES: MULTIPLE LOCATIONS O F D UCTWORK WITHIN SECOND FLOOR CEILING SPACES SHALL BE REQUIRED TO FOLLOW A RCHITECTURAL CEILING SLOPES. MC TO COORD INATE WITH GC FOR EXACT SLOPES AND DUCT ROUTING PRIOR TO DUCTWORK CON STRUCTION. PROVIDE ACCESS PANELS AS NEEDED FOR ALL EQUIP MENT ABOVE HARD LID CEILINGS REQUIRING MAIN TEN ANCE. ALL PANELS SHALL BE PAINTED IN ACCORDANCE WITH AR CHITE CTURAL R EQUIREMENTS. 1. 2. Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 M2.2 HV A C S E C O N D F L O O R PL A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' HVAC SECOND FLOOR PLAN 8' 16' 13 FEB 2017 GRILLES, REGISTERS AND DIFFUSERS SCHEDULE NUMBER MAKE & MODEL N UMBER D-1 TITUS OMNI-3 SUPP LY REMARKSDESCRIPTIONCOLORFRAME SIZEDUTY N ECK SIZE FRAME TYPE FRAME CO NST DAMPER ARCHITECTURAL UNI-FLO DIFFUSER WHITE 24/24 LAY-IN STEEL N OSEE PLAN D-2 TITUS OMNI-1 SUPPLYARCHITECTURAL UNI-FLO DIFFUSER WHITE 24/24 SURFACE STEEL YESSEE PLAN D-3 TITUS OMNI-1 SUPP LYARCHITECTURAL UNI-FLO DIFFUSER WHITE 1 2/12 SURFACE STEEL YESSEE PLAN D-4 TITUS 300RL-1 SUPP LYSIDEWALL SUPPLY DIFFUSER WHITE SIDEWALL STEEL YESSEE PLAN D-5 TITUS TDC-3 SUPP LYDIRECTIONAL DIFFUSER WHITE 24/24 LAY-IN STEEL N OSEE PLAN WITH TRIM FRAME WITH TRIM FRAME SEE PLAN 18x18 DUCT SIZE WITH ROUND NECK D-6 TITUS TDC-1 SUPP LYDIRECTIONAL DIFFUSER WHITE SURFACE STEEL N OSEE PLAN NECK + 6" D-7-1-4 TITUS CT-480 SUPP LYLINEAR FLOOR DIFFUSER - 1/4" SPACING / 1/8" B ARS PER ARCH LAY-IN ALUM N OSEE PLAN 48" LONG - # INDICATES NUMBER OF SLO TS - WITH SUPPLY PLENUM D-7-3-#TITUS TBD-30 SUPPLYADJUST PLENUM SLOT DIFFUSER 1.0" SLOTS WHITE LAY-IN ALUM N O48x4"48" LONG WITH MATCHING SIZED PLENUM CONSTRUCTED BY MC D-8-1-#TITUS ML-37 SUPPLYADJUST LIN EAR SLOT DIFFUSER 0.5" SLOTS WHITE SURFACE ALUM YESSEE PLAN 48" LONG - # INDICATES NUMBER OF SLOTS - WITH SUPPLY PLENUM AND 2A BORDER D-8-2-#TITUS ML-38 SUPPLYADJUST LIN EAR SLOT DIFFUSER 0.75" SLOTS WHITE SURFACE ALUM YESSEE PLAN 48" LONG - # INDICATES NUMBER OF SLOTS - WITH SUPPLY PLENUM AND 2A BORDER D-8-3-#TITUS ML-39 SUPPLYADJUST LIN EAR SLOT DIFFUSER 1.0" SLOTS WHITE SURFACE ALUM YESSEE PLAN 48" LONG - # INDICATES NUMBER OF SLOTS - WITH SUPPLY PLENUM AND 2A BORDER D-9 TITUS S300FL SUPPLYDUCT MOUNTED SUPPLY DIFFUSER GALV SIDEWALL ALUM YESSEE PLAN NECK + 3" G-1 TITUS PAR-3 RETURNPERFORATED FACE GRILLE WHITE LAY-IN STEEL NO24/24 22/22 G-2 TITUS PAR-3 R ETURNPERFORATED FACE GRILLE WHITE LAY-IN STEEL NO24/12 22/10 G-3 TITUS 355RLF R ETURNLOUVERED FACE FILTER GRILLE WHITE SURFACE STEEL NO G-4 R ETURNPERFORATED FACE GRILLE WHITE SURFACE STEEL NO24/12 22/10 G-5 TITUS 350RL-1 R ETURNLOUVERED FACE GRILLE WHITE SURFACE STEEL NOSEE PLAN SEE PLAN R-1 TITUS PAR-3 RETURN/ EXHAUST PERFORATED FACE REGISTER WHITE LAY-IN STEEL YES24/24 22/22 R-2 TITUS PAR-3 PERFORATED FACE REGISTER WHITE LAY-IN STEEL YES24/12 22/10RETURN/ EXHAUST R-3 TITUS 8F-1 PERFORATED FACE REGISTER WHITE SURFACE ALUM YES24/24 22/22RETURN/ EXHAUST R-4 TITUS 8F-1 PERFORATED FACE REGISTER WHITE SURFACE ALUM YES12/12 10/10RETURN/ EXHAUST R-5 TITUS 350FL-1 EXHAUSTLOUVERED FACE REGISTER WHITE SURFACE ALUM YESSEE PLAN SEE PLAN APPROVED MANUFACTURERS: METALAIRE, KRUEG ER WITH 1" FILTER TO MATCH NECK SIZESEE PLAN N ECK + 4" G-6 TITUS 350RLF1 RETURNLOUVERED FACE FILTER RETURN GRILLE WHITE SURFACE STEEL N O24/12 24/24 22/10 22/22 WITH 1" FILTER ACCEPTANCE REFER TO PLANS FOR SIZE TITUS PAR-3 WITH TRIM FRAME 1 LOUVER SCHEDULE NUMBER MAKE & MODEL NUMBER DUTY WIDTH IN CHE S HEIG HT INCHES SF FREE AREA REMARKS LVR-1 POTTORFF EFD-435 CONSTFIXED DEPTH IN CHES CFM FPM @ CFM APD @ CFM H2O PENE VEL- FPM PER ARCHALUMEXHAUSTYES8484420,400 FRAME STYLE COLOR SCREE N 30.3 675 0.07"966 FLANGED BIRD 1 LVR-2 POTTORFF EFD-435 PER ARCHALUMINTAKEYES8484420,400 30.3 675 0.07"966 FLANGED BIRD 1 1 PRIMER FINISH - TO BE FIELD PAINTED LVR-3 POTTORFF EFD-435 PER ARCHALUMEXHAUSTYES181841,050 1.0 1,050 0.1"966 FLANGED BIRD 1 VARIABLE AIR VOLUME TERMINAL SCHEDULE NUMBER MAKE & MODEL NUMBER REMARKS VAV-1-1 KRUEGER QF V-05 1 RATED FOR 7,000 FT ELEVATION 14"Ø 1 INLET SIZE OUTLET (WxH) 15.5x14 TYPE PARALLEL FAN PWR 3,060 MAX CFM 750 MIN CFM 850 FAN CFM 2,450 HEAT CFM 1" INLET S.P. 1/2 FAN HP 12 ELEC KW 3 STEPS EAT 59.5 LAT 80.1 ELEC DATA 208/3 ELECTRIC HEATING COIL 2 ISOLATION HANGER KIT 3 ELECTRIC HEATIN G COIL WITH FUSED DISCONNECT SWITCH 4 REMO TE 24 VOLT TEMPERATURE SENSOR - SETPOIN TS CONTROLLED THROUGH BAS SYSTEM 2 3 4 VAV-1-2 1PARALLEL FAN PWR 2 3 4 VAV-1-3 1PARALLEL FAN PWR 2 3 4 VAV-2-1 1PARALLEL FAN PWR 2 3 4 VAV-2-2 1 3 4 VAV-2-3 1PARALLEL FAN PWR 2 3 4 PARALLEL FAN PWR KRUEGER QF V-05 14"Ø 15.5x142,960 750 850 2,450 1"1/2 12 3 59.5 80.1 208/3 KRUEGER QF V-03 8"Ø 11.5x11.59504503007501"1/10 5.5 3 60.2 91 208/3 KRUEGER QF V-06 14"Ø 15.5x143,570 750 1,000 2,750 1"1/2 14 3 59.7 81.1 208/3 KRUEGER QF V-06 14"Ø 15.5x143,570 750 1,000 2,750 1"1/2 14 3 59.7 81.1 208/3 KRUEGER QF V-03 8"Ø 11.5x11.58604502757001"1/10 5 3 60.1 90.1 208/3 2 DUCT FURNACE SCHEDULE (GAS FIRED) N UMBE R MAKE & MODEL NUMBER DF-1 REZNOR SC-250 1 1 LESS FINGER-BAFFLES - REMO VED IN FIELD MBH IN AT S.L. G AS TYPE GA S CONN FLUE SIZE REMARKS 2 3300 EFF.CA SIZE WEIGHT (LBS)CONTR OLELEC DATA 80%NAT 5,400 1.9 120/1 3/4"7"Ø 7"Ø 325 CFM FLA A DF-2 REZNOR SC-300 1 335080%NAT 7,000 1.9 120/1 3/4"7"Ø 7"Ø 350 A 4 4 DF-3 REZNOR SC-350 1 340080%NAT 8,000 1.9 120/1 3/4"7"Ø 7"Ø 410 A 4 2 RIGHT SIDE CON TRO LS 3 50-100% ELECTRON IC MODULATING FIRING RATE 4 FACTORY PR OVIDED STANDAR D VERTICAL VENT TERMIN AL/COMBUSTION AIR INLET ASSEMBLY CONDENSING UNIT SCHEDULE N UMB ER MAKE & MODEL NUMBER REMARKS 1 MOUNT ON 6" THICK CONCRETE PAD ELEC VOLTAGE N O. STAGES NO. CIRCUIT S SEER WEIGHT LBS MIN CIR AMPS MAX FUSE CU-1 CU-2 CU-3 TRANE TSA150S4D 2 2 -585 49 60 208/3 AHU-1 1 INDOO R UNIT AHU-2 1 AHU-3 1 2 LO N G LINE SET - SIZED BY EQUIPMENT PROVIDER 2 2 2 TRANE TSA180S4D 2 2 -8255 66 90 208/3 TRANE TSA240S4D 2 2 -915 78 100 208/3 3 COIL HAIL G UARD 4 LO W AMB IENT CONTROLS 3 4 3 4 3 4 NOMINAL TONS 12.5 15 20 ELECTRIC HEATER SCHEDULE NUMBER MAKE & MODEL N UMBER ORIEN -TATIO N TOTAL WATTS CFM HOUSIN GCONS T HOUSIN GCOLOR INTERNAL TSTAT INTERNAL DISCON N ELEC DATA AMPS REMARKS EWH-1 WALL EWH-2 RECESSED FRAME RECESSED FRAME WALLMARKEL E3322TD-RP 175 STEEL STD YES YES 120/1 8.3 MARKEL E3322TD-RP 175 STEEL STD YES YES 120/1 8.3 1,000 1,000 PACKAGED ROOFTOP UNIT SCHEDULE NUMBER MAKE & MODEL N UMBER RTU-1 DAIKIN MPS007B 3,000 81%1 1 W/ 100% MODULATING ECONOMIZER PO WER EXHAUST TONS NOMINAL ORIEN- TATION TOTAL CFM OA CFM FAN RPM EXT STATIC MOTOR BHP/HP MBH IN HEATIN G MBH OUT5000 FT AFUE FUEL TYPE HEATING STAGES COOLING STAGES TOT MBH COOLING SENS MBH ENT D B DEG . F ENT WB DEG. F AMB IENT DB REF TYPE EER (SEER) FILTER TYPE TSTAT TYPE MIN CIR AMPS MAX FUSE ELEC VOLTAGE HEIGHT W/CURB LEN GTH WIDTH WEIG HT W/CURB REMARKS 2 3 14" TALL FLAT ROOF CURB (INCLUD ED IN UN IT HEIGHT)4 CONDENSER COIL HAIL G UARD 5 VERTICA L FLUE DISCHARGE 6 UNIT MO UN TED DISCONNECT 7 SMOKE DETECTOR IN RETURN AIR SYSTEM COMPLYING WITH SECTION 606 OF 2009 IMC 2 3 4 5 6 77VERT1,023 1"1/1 150 97.2 NAT GAS 73.2 67.2 78 61 95 R -410A 11.2 43 50 208/3 1,100 LB500DDC4'-1"7'-4"4'-10"1 2"2 AIR HANDLING UNIT SCHEDULE NUMBER MAKE & MODEL NUMBER AHU-1 DAIKIN CAH012GDAC 5,400 1 1 W/ 100% MODULATING ECONOMIZER TO NS NOMINAL ORIEN- TATION TOTAL CFM OA CFM FAN RPM EXT STATIC MOTOR BHP/HP TOT MBH COOLING SENS MBH ENT DB DEG. F ENT WB DEG. F AMBIENT DB REF TYPE EER (SEER) FILTER TYPE TSTAT TYPE MIN CIR AMP S MAX FUSE ELEC VOLTAGE HEIG HT LENGTH WID TH WEIG HT W/CURB REMARKS 2 UNIT MOUNTED DISCONNECT 3 SMOKE DETECTOR IN RETURN AIR SYSTEM COMPLYING WITH SECTION 606 OF 2012 IMC 12.5 HORIZ 3,063 2.5"4.8/7.5 146.2 114.4 78 61 95 R-410A ---208/3 1,71 51,700 DDC 3'-10"10'-4"6'-2"MERV 13 AHU-2 DAIKIN CAH014GDAC 7,000 116HORIZ3,582 2"7.35/1 0 213.1 149.3 78 61 95 R-410A ---208/3 3,4551,600 DDC 3'-10"17'-8"7'-8"MERV 13 AHU-3 DAIKIN CAH017GDAC 8,000 120HORIZ3,159 2"7.38/1 0 216.1 168.9 78 61 95 R-410A ---208/3 90001,600 DDC 7'-3"25'-11"7'-10"MERV 13 LAT DB DEG. F LAT WB DEG. F52.4 50.3 52.2 50.1 52.5 50.3 SUPPLY FAN FAN RPM EXT STATIC MOTOR BHP/HP --- 988 1"3.8/5 1,057 1"4.8/7.5 RETURN FAN EXHAUST FAN SCHEDULE NUMBER MAKE & MODEL N UMBER CFM FAN SPEED EXT STATIC D RIVE TYPE REMARKS EF-1 TWIN CITY FAN 080 DBS NO0.5"1/2 HP 10.1 BELT DUTYTYPE MOTOR HP/W SON ES ELEC DATA SPEED CON TROL G RILLE TYPE HOUSING CONST CO NTROL INLIN E CABINET 1,205 RPM N/A G ALV 120/1A 1 1 GRAVITY BACKDRAFT DAMPER EF-2 EF-3 2 SPEED CONTROLLER MOUNTED AT FAN FOR P URPOSES OF BALANCING EXHAUST 1,250 EXHAUST 70 EXHAUST 300 TWIN CITY FAN T080 CEILING CABINET YES0.25"48 W 3.8 DIRECT1,550 RPM PLASTIC G ALV 120/1C 1 3 WITH FLAT R OOF CAP TWIN CITY FAN T300 NO0.25"212 W 3.3 DIRECT905 RPM PLASTIC G ALV 120/1B 1 2 4 A ON DURING OCCUPIED PERIO DS B CONTROLLED BY THERMOSTAT SET FOR 80°F C CONTR OLLED BY WALL SWITCH UNDER ELECTRICAL SCOPE 4 WITH WALL CAP 2 3 CEILING CABINET Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 M8.1 HV A C S C H E D U L E S JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 13 FEB 2017 FLAG NOTES: 4" WASTE LINE CONTINUED. REFER TO CIVIL SITE PLAN FOR CONTINUATION. 2" WASTE UP AND CAPPED. 3" WASTE UP AND CAPPED. PIPING UPSTREAM OF THIS POINT IS LOCATED AT A FIRST FLOOR SUB-SURFACE LEVEL. PIPIN G AT THIS POINT IS TO DROP DOWN TO B ELOW BASEMENT SLAB LEVEL IN AREA OF FUTURE WALL. 4" GREASE WASTE LINE SHALL BE ROUTED TO GREASE INTERCEPTOR. REFER TO CIVIL SITE PLAN FOR CO NTINUATION . PROVIDE AND INSTALL FLOOR DRAINS AS SHOWN. COORDIN ATE WITH MC FOR EXACT INSTALLATION LOCATION TO AVOID CONFLICT WITH MECHANICAL EQUIPMEN T. REFER TO MAIN BUILDING WASTE AND VENT ISOMETRIC ON SHEET P4.1 FOR WASTE AND VENT REQUIREMEN TS UPSTR EAM OF THIS POINT. SUMP PUMP (SP-1) INSTALLED RECESSED IN ELEVATO R PIT SLAB. ROUTE PRESSURIZED PIPE UP AND BEG IN GRAVITY PIPE AT SLAB LEVEL WITHIN PIT. OIL IN TERCEPTOR (OI-1) IN STALLED RECESSED IN STORAGE CLOSET SLAB. MAINTAIN HIGHEST WASTE LINE ELEVATION POSSIBLE UPSTREAM AND DOWN STREAM OF THIS POINT. ROOF DRAIN PIPING DOWN WITHIN CHASE. BEGIN ROUTING TIGHT TO STRUCTURE AND ALO NG PERIMETER WALL AS INDICATED. 2" VEN T FROM OI-1 ABOVE SLAB AN D UP IN THIS LOCATION. CONTINUE WITHIN FURRING UP THROUGH ROOF. CONNECT 4" RD PIPING TO PERIMETER STORM DRAIN PIPING RUNNING AT EXTER IOR OF BUILDING FOUNDATION . REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF PIPING CONNECT 3" AD PIPING TO PERIMETER STORM DRAIN PIPING RUNNING AT EXTERIOR O F BUILD IN G FOUNDATION . REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF PIPING. PROVIDE ZURN FD-2210 ADJUSTABLE DRAIN WITH ABS SOLVENT WELD CO NNECTION . DO NOT TRAP THIS FIXTUR E. FEILD VERIFY AND COO RDINATE EXACT IN STALLATION LO CATION OF AREA DRAINS LOCATED AT THIS EXTERIOR PATIO AREA. REFER TO GREASE PUMPS SCHEDULES AND DETAILS ON SHEET P6.2 FOR MORE INFORMATION AND REQUIREMEN TS OF THIS SYSTEM. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B.1 C C.1 E F.1 1 2 3 4 5 6 7 11 12 H G' G E'E.5D.2DB.9 B F W W 4" 3" G W OI-1 SP-1 2" 4" G WW 4" 4" G CO-1 4" W 1 5 8 9 3" 2" G W 3" FS-1 4 11 R D V 2" 14 12 3" 3" FCO-1 2" AAV-1 TERMIN ATE 6" A.F.F. TIGHT ADJACEN T TO EQUIP MENT CUR B 6 2" FD-1 62" FD-1 AHU-1 RE: HVAC DWGS AHU-2 RE: HVAC DWGS 62" FD-1AHU-3 RE: HVAC DWGS G W W G WW G W W 3" FS-1 2" FD-1 2" FD-1 2 2 2 2 2" FD-1 2" 3" 3" 2" 2" 3" 4" WASTE TRENCH, BY OTHERS2" FD -1 3" 2" 3" 2" 3" 3" 4" 2" FD-1 2" 4" 4" 2" 4" 4" FD-1 4" 2" 3" PATIO DRAIN 13 13 14 3" 3" G W G W W 2" 2" 2" FD -1 3" 2" 7 GP-1 END OF LINE CO 4" 15 PIPING INSTALLED AS HIGH AS POSSIBLE 9 8 10 LAV-1 WC-1 2 MSB-1 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P1.0 WA S T E A N D V E N T BA S E M E N T F L O O R PL A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' WASTE AND VENT BASEMENT FLOOR PLAN 8' 16' 1 13 FEB 2017 B.1 C C.1 E F.1 1 2 3 4 5 6 7 11 12 G' G E'E.5D.2DB.9 B F 4" GCO-1 4" GC O-1 4" GC O-1 4" GCO -1 4" GCO-1 4" GCO-1 PD PD P D P D P DPDPD PD PD P D 0.5% 0.5 % 0.5 % PERIMETER D RAIN AGE INSTA LLATION NOTES: 1. ALL PE RIMETER DRAINAG E SYSTEM PIPING SHALL BE 4". 2. REFER TO G ENERAL PLUMBING NOTES ON SHEET P0.1 FOR MORE PIPE REQUIREMENTS. 3. REFER TO ARCHITECTURAL P LANS FOR DETAILS ON ACTUAL INSTALLATION REQUIREMENTS. 4. ALL AREA DR AINAGE PIPING SHALL BE SOLID WALL PIPING. SP-2 1 4" GCO-1 4" FCO-1 4" FCO-1 4" FCO-1 P D 0.5 % P D 0 .5 % 8" 'POND PIPE' BY OTHERS 0.5 % PD 0.5 % 0.5 % P D 0 .5 % 0 .5 %4" GCO-1 PD 0.5% PD 0.5 % PD 0.5% 2" 4" P D 0 . 5 % 2 3 3" AD-1 3" AD -1 AD A D 4" 3" 4 5 6 7 8 3" AD-1 3" A D 4" GCO-1 9 0 .5 % 10 10 10 SP-3 4" FCO-1 2" 11 12 13 9 8 10 FLAG NOTES: SP-2 TO BE INSTALLED WITHIN AREA OF LOWER ED SLAB. COORDINATE WITH GC FOR EXACT INSTALLATION LOCATION TO MAINTAIN ANY CLEARNACE TO LOWERED FOOTINGS. CONNECT 4" PERIMETER DRAINAGE PIPING TO 8" 'POND PIPE' IN THIS GENERAL AREA. POND PIPE IS BY OTHERS. FIELD VER IFY EXACT LOCATION. 4" PERIMETER DRAINAGE PIP E TO DROP DOWN TO BELOW LOWER ED SLAB ELEVATION IN THIS AREA. VERTICAL PIPING SHALL BE SOLID WALL PIPE. CONNECT 3" AREA DRAIN AND 4" PERIMETER DRAIN PIPING INTO (1) SOLID WALL 4" PIPE. ROUTE THROUGH FOUNDATION AS IN DICATED. BEGIN GRAVITY DR AINAGE OF PIPE AT THIS POINT. ALL PIP ING D OWN STREAM OF THIS POINT SHALL BE SOLID WALL PIPE. COMBINE (2)4" P ERIMETER DRAINS INTO (1) 4" SOLID WALL P IPE AT THIS POINT. ALL PIPING DOWNSTREAM OF THIS POINT TO BE SOLID WALL. COMBINE (3)4" P ERIMETER DRAINAG E PIPES INTO (1)4" PIPE AT THIS POINT. PIPING DOWNSTREAM OF THIS POIN T SHALL BE SOLID WALL PIPING. COMBINE 4" AREA DRAIN PIPE AND 4" PERIMETER DR AIN PIPE IN TO (1)4" PIPE AND CONTINUE TO SP-2. 4" SOLID WALL PIPING TO BE CON TINUED ALONG FOUN DATION WALL TRENCH. PC OPTION TO EITHER R OUTE TO SP-2 OR CONTIN UE TO GRAVITY DRAIN CONN ECTION AT 'POND P IPE'. FIELD VERIFY REQUIREMENTS OF EITHER O PTION . DO NOT TRAP THIS FIXTURE. THIS 4" SUBSURFACE DRAIN TO BE AT BOTTO M OF ELEVATOR PIT FO OTING ELEVATIOON . ROUTE PIPE AS IN DICATED AND SLOPE TO SP-3. 2" PUMP PRESSURIZED DISC HARGE LINE TO BE ROUTED ALONG WA LL WITHIN AREA B ENEATH STAIRWELL. ROUTE AS INDICATED AN D CON NECT TO BURRIED SOLID WALL ROOF DRAIN PIPING IN THIS AREA. GRAVITY LINE JUST BEFORE CON NECTION TO ROOF DRAIN LINE. REFER TO ARCH PLANS FOR R OOF DRAIN LINE LOCATION. CONNECT VENT LINE FROM DISCHARGE PIP E AND SP-3 BASIN TO 2" VEN T LINE SERVING OI-1 IN THIS SAME AREA. 1 2 3 4 5 6 7 8 9 10 11 12 13 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P1.1 SU B - S U R F A C E DR A I N A G E P L A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' SUB-SURFACE DRAINAGE PLAN 8' 16' 1 13 FEB 2017 A B.1 C C.1 E F.1 1 2 3 4 5 6 7 11 12 H G' G E'E.5D.2DB.9 B F C W F 2" CW SERVICE FIRE SERVICE C W H W H W C C W H W H W C0.5" 0.75" 2" 2" C W H W H W C 1.5" CW 1.5" 0.5" WC-1 LAV-1 0.75" PWH-2 PWH-1 DF-1 RE: HVAC DWGS DF-2 RE: HVAC DWGS DF-3 RE: HVAC DWGS G G G G G G G G G G 2.5" 2"1.5"1" 1.25" 1.5" 1.25" 5 1 2 3 4 6 7 7 7 1.25" G 2.5" 1 1 1.5" HW3 1 1.5" 0.5" 1.25" 1 9 8 10 8 B-1 P-1 GF-1 12 S M S /S M R S M S /S M R1.25" 10 10 9 1.25" LAV-1 MSB-1 WC-1 0.75" 2 FLAG NOTES: REFER TO WATER SERVICE ENTRY DETAIL ON SHEET P6.1 FOR WORK REQUIRED WITHIN THIS AREA. REFER TO POTABLE WATER HEATER IN STALLATION DETAIL ON SHEET P6.1 FOR WORK REQUIRED IN THIS AR EA. 1.5" CAPPED WITH SHUT-OFF VALVE FOR FUTURE CONNECTION. ROUGH-IN THIS PLUMBING FOR CONNECTION TO FUTURE RESTROOM. 1.5" CW, 1.25" HW AN D 0.5" HWC UP WITHIN CHASE ON FIR ST FLOOR. REFER TO WATER AND GAS ENLARGED FIRST FLO OR PLAN ON SHEET P5.1 FOR CONTINUATION UP. PIPING UP TO FIRST FLOOR. REFER TO PLUMBING FIRST FLOOR PLAN ON SHEET P3.1 FOR CONTIN UATION UP. CONNECT GAS TO EQ UIPMENT WITH GAS COCK, UNION AND FULL SIZE 6" DIRT LEG . THIS AREA REPRESEN TS A PORTION OF THE SNOWMELT SYSTEM. REFER TO WATER AN D GAS BASE MENT FLOOR PLAN FOR THE ADDITIONAL REQURIED AREA AN D TO SHEET P5.1 FOR FURTHER SCHEDULES AND DETAILS. SNOWMELT SYSTEM SENSOR LO CATION (SENSOR 1 OF 2). THIS LINE IS REPRESENTATIVE OF (2) PIPE RUNS. 1" SNOW MELT SUPPLY (SMS) AN D SNOW MELT RETURN (SMR) SHALL BE RAN FROM BOILER LOCATION TO MANIFOLD LOCATION AS IN DICATED. 1.25" SMS & SMR PIPING TO SNOW MELT MAN IFOLD WITHIN WALL AT THIS LOCATION. COORDIN ATE EXACT INSTALLATION REQUIREMENTS WITH GC. REFER TO SNOWMELT BOILER SYSTEM INSTALLATION SCHEMATIC ON SHEET P6.3 FOR WORK ASSOCIATED WITH THIS SYSTEM IN THIS AREA. 1 2 3 4 5 6 7 8 9 10 11 12 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P2.0 WA T E R A N D G A S BA S E M E N T F L O O R PL A N Author 1/23/2017 Checker STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' WATER AND GAS BASEMENT FLOOR PLAN 8' 16' 2 2 2 13 FEB 2017 A B.1 C C.1 E F.1 1 2 3 4 5 6 7 11 12 H G' G E'E.5D.2DB.9 B F CW HW HWC 0.75" 0.5" G 2.5" GAS SER VICE 3 1 2 6 4 5 1 W W 2" 3" 4" 4" 3" FD-1 3" FD-1 2" FS-1 4" 7 7 G W 3-COMP SINK, BY OTHERS 3" FS-1 SINK , BY OTHERS HAN D SINK, BY OTHERS 2" 3" 2" 8 9 9 8 10 10 10 11 12 12 2 FLAG NOTES: 0.5" HW & HWC AN D 0.75" CW UP WITHIN WALL FROM BASEMENT. ROUTE AS INDICATED WITHIN FIRST FLOOR CEILING AND UP TO RESTROOM FIXTURES ON SECOND FLOOR. REFER TO ENLARGED FIRST FLOOR RESTROOM GROUP PLAN ON SHEET P5.1 FOR ALL WORK REQUIRED WITHIN THIS AREA. PROVIDE AND INSTALL BALL VALVE, BALANCE VALVE AND CHECK VALVE FOR HWC SYSTEM. INSTALL IN AN ACCESSIBLE LO CATION AND PRO VIDE ACCESS PANEL IF NECESSARY. LOCATION OF GAS METER. COORDINATE WITH GAS UTILITY SERVICE COMPANY TO PROVIDE NEW METER SIZED FO R 2,521 MBH (2,868 CFH) AT 14" DELIVER Y PRESSURE. REFER TO WATER AND GAS ENLARGED FIRST FLOOR PLAN ON SHEET P5.1 FOR PIPIN G CONTIN UATION. REFER TO CIVIL DRAWING S FOR CONTIN UATION. REFER TO MAIN BUILD ING WASTE AND VEN T ISOMETRIC ON SHEET P4.1 FOR WASTE AN D VENT REQ UIREMENTS IN THIS AREA. REFER TO WASTE AN D VENT BASEMENT FLOOR PLAN ON SHEET P1.0 FOR CON TINUATION. 4" RD DOWN FROM ABOVE. ROUTE TO B ELOW SLAB AND CONNECT TO EXTERIOR ROOF DRAIN PIPING BELOW GRADE. THIS AREA REPRESENTS A PORTION OF THE SN OWMELT SYSTEM. REFER TO WATER AND GAS BASEMENT FLOOR PLAN FO R THE AD DITIONAL REQ URIED AREA AN D TO SHEET P5.1 FOR FURTHER SCHEDULES AND DETAILS. SNOWMELT SYSTEM SENSOR LOCATION (SEN SO R 2 OF 2). ROUTE DRAIN FROM THIS FIXTURE TO NEAREST FLOOR SINK WITH AIR-GAP. 1 2 3 4 5 6 7 8 9 10 11 12 2 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P3.1 PL U M B I N G F I R S T FL O O R P L A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' PLUMBING FIRST FLOOR PLAN 8' 16' 1 1 1 2 13 FEB 2017 DN PF A B.1 C C.1 E F.1 1 2 3 4 5 6 7 8 9 10 11 12 H G' G E'E.5D.2DB.9 B F DF-1 WC-1 (2)WC-2 (2)LAV-2 LAV-2 WC-2 (2)LAV-2 2 4 7 1 1 3 5 6 6 R D R D4" C W 8 0.75" 9 G 1" GAS UP TO ROOF UP FROM FLOOR BELOW 2 LAV-2 WC-13 0.5" CW TO ICE MAKER HANDSINK BY OTHERS 3-COMP SINK BY OTHERS SINK BY OTHERS MSB-1 1 LAV-2 WC-1 1 3 1 G W 3" FS-1 3" 3" 2" 3" GW DOWN W 10 4" 2" FS-1 2" 11 11 2 2 FLAG NOTES: 0.5" HW & CW UP TO LAV FROM FLOOR BELOW. 0.75" HW & CW UP FRO M FLOOR BELOW. 0.5" HW & CW TO EACH LAV. 0.75" CW UP TO WC FROM FLOOR BELOW. 0.75" CW UP FROM FLOOR BELOW. 0.75" CW TO EACH WC. 0.5" CW UP TO DF FROM FLOOR BELOW. ROOF DRAIN PIPING FROM MECHAN ICAL ROOF WELL. ROUTE AS INDICATED AND DOWN WITHIN FURRED WALL TO BASEMENT. 0.75" CW UP FROM FLOOR BELOW. O.75" CW TO WC AND 0.75" CW CONTINUED UP TO CEILING SPACE AND ROUTED AS SHOWN . 0.75" CW UP TO ROOF HYDRANT O N ROOF. REFER TO PLUMBING ROOF PLAN ON SHEET P3.3 FO R CON TINUATIO N. 0.75" PVC DRAIN LINE FROM ROOF HYDRANT. ROUTE FROM HYDRANT CONNECTION AND TERMINATE TO NEAREST LAV TAIL PIECE WITH AIR GAP FITTIN G. 2" WASTE CONTINUED. REFER TO MAIN RESTRO OM GROUP W&V ISOMETRIC ON SHEET P4.1 FOR WASTE CONTINUATION. ROUTE DRAIN FROM THIS FIXTURE TO N EAREST FLOOR SINK WITH AIR-G AP. 1 2 3 4 5 6 7 8 9 10 11 2 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P3.2 PL U M B I N G S E C O N D FL O O R P L A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' PLUMBING SECOND FLOOR PLAN 8' 16' 13 FEB 2017 A B.1 C C.1 E F.1 1 2 3 4 5 6 7 8 9 10 11 H G' G E'E.5D.2DB.9 B F RD-1 RH-1 RTU-1 RE: HVAC DWGS 1" GAS UP FROM FLOOR BELOW 1" GAS CAPPED WITH GAS COCK FOR FUTURE EQUIPMENT CONNEC TION1 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P3.3 PL U M B I N G R O O F PL A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 13 FEB 2017 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ SCALE: MAIN RESTROOM GROUP WASTE & VENT ISOMETRIC NONE 2" VE NT UP TO 3" VTR V 3" 2" WCO-1 2" WC-1 LAV-2 3" WASTE RE: PLANS FOR CONTINUATION 3"2" SCALE: MAIN RESTROOM GROUP WASTE & VENT ISOMETRIC NONE 4" WCO-1 4" WC-1 WC-2 4" 4" 4" 4" WASTE RE: PLANS FO R CON TIN UATION 3" WCO-1 4" LAV-2 WC-1 WC-2 LAV-2 3" 2" 2" 2" 2" 2" 2" 2" LAV-2, TYP OF (4) UR-2 UR-1 3" 3" 3" 3" 2" 2" 2" WC-2 WC-2 WASTE STA CK WITHIN CHASE 4" VENT STACK WITHIN CHASE WC-1 WC-1 WC-1 2" WCO-1 2" 2" 4" 3" 2" DF-1 2" 3" V UP TO 3" VTR 2" 4" WCO-1 V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V LAV-2 LAV-2 LAV-2 MSB-1 MSB-1 2" 2" 3" 2" 2" 2" 2" 3" 3" 3" 3" WCO-1 4" 2" WASTE STACK WITHIN WALL VENT STACK WITHIN WALL 2" 2" 2"3" 2" WCO-1 DF-1 2" 3" V V 2" V CONT. 2" W CONT. 2" W CONT. WC-1 2" V CONT. SCALE: TYPICAL SINK FIXTURE WASTE & VENT ISOMETRIC NONE 2" VENT CONTINUED V FIXTURE 2" WASTE CONTIN UED 2" WCO 2" SCALE: WARMING KITCHENS WASTE & VENT ISOMETRIC NONE V V V V V V V V V V V V V V 2" FS-1 3" FS-1 2" 2" REFER TO PLANS FOR CON TINUATION REFER TO PLANS FOR CONTINUATION SINK BY OTHERS 2" FS-1 2" WCO-1 2" 3" FS-1 3" 3" WCO-1 REFER TO PLANS FOR CONTINUATION V V V 3" V UP TO 3" VTR 2" 4"3" 4" GW G W 2" 2" 2" 2" 2" 2" 2" 2" 3" 3" GW DOWN TO FIR ST FLOOR 3" Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P4.1 WA S T E A N D V E N T IS O M E T R I C S JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 1 1 1 2 2 13 FEB 2017 PF 11 12 H G' GE'E.5D.2 F 1.5" CW 1 " HW 0.5" HWC 1" 1.5"0.5" HANDSINK , BY OTHERS C W H W H W C 1 2 C W H W 3-COMP SINK BY OTHERS 9 WC-1 WC-2 UR-2 UR-1 WC-2 (4)LAV-2 8 4 8 4 8 5 66 1" 0.5" 7 1" 0.75" 1" 0.75" 3 0.75" 1.5" 1" 1.5" H W C W H W C 11 10 2.5" GAS 1 SIN K BY OTHERS 0.5" CW UP /DOWN TO ICE MAKER 0.5" 0.75" 0.75" HW & CW UP TO 3-COMP SINK 0.75" 1" 1" 0.75" UP TO SIN K 0.75" DO WN TO SINK 0.5" HW TO UNDERCOUNTER DISHWASHER MSB-1 6 12 0.5" TO DF-1 1 1 1 2 FLAG NOTES: 1.5" CW, 1" HW & 0.5" HWC UP WITHIN SHAFT FROM FLOOR BELOW. PROVIDE BALL VALVE ISOLATION AS INDICATED. 0.5" UP TO EWC-1 ON SECOND FLOOR. 0.75" CW & HW UP. 0.5" HW & CW TO EACH LAV-2. 0.5" CW & HW UP TO LAV-2. 0.75" CW UP TO WC-1 ON SECOND FLOOR . 0.75" HW & CW DOWN. 0.5" HW & CW TO EACH LAV-1. 0.75"" CW UP OR DOWN. 0.75" CW TO EACH FIXTURE. PROVIDE AND INSTALL BALL VALVE, BALANCE VALVE AND CHECK VALVE FOR HWC SYSTEM. INSTALL IN AN ACCESSIBLE LOCATION AND PROVIDE ACCESS PANEL IF NECESSARY. 2.5" G AS FROM METER. REFER TO PLUMBING FIRST FLOOR PLAN ON SHEET P3.1 . 2" GAS DO WN TO BASEMENT AND 1" GAS UP TO FLOOR ABOVE. REFER TO THOSE FLOOR PLANS FOR P IPIN G CONTINUATIONS. 0.75" HW & CW UP AN D DOWN TO MSB-1. 1 2 3 4 5 6 7 8 9 10 11 12 Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P5.1 WA T E R A N D G A S EN L A R G E D F I R S T FL O O R P L A N JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' ENLARGED PLUMBING FIRST FLOOR PLAN 4' 8' 13 FEB 2017 5" V SCALE: WATER SERVICE ENTRY DETAIL NONE 2" CW 3" COPPER DRAIN FROM RPBP 2" RPBP-1 2" COPP ER DRAIN FROM RPB P 1" RPBP-2 CW IRR DISCHARG E 2" ABOVE FLOO R DRAIN, TYP PENETRATE SLAB WITH PVC SLEEVE, TYPICAL 4" FD-1 STRAIN ERIRRIGATION SHUT-OFF 1.5" CW SERVICE 1.5" WATER METER INSTALLED IN ACCORDANCE WITH CITY STANDARDS 2" CW CW WATER MAIN FINISHED GRADE CURB VALVE IN VALVE BOX 1" IRRIGATION. CAP PIPE AND PR OVIDE MARKER AT G RADE. VERIFY SIZE PRIOR TO INSTALLATION BUILDING CW SHUT-OFFM 1.5" WATTS 45B PRESSURE REDUCIN G VALVE SET AT 75 PSI 2" WATER CLOSET - KOHLER SAN SOUCI, K-5172, ELON GATED, WHITE VITREOUS CHIN A, 16.5" TALL, ADA, 1.28 GPF, 12" ROUGH-IN, LH/RH SELECTED BY PC AT ORDERING, SATIN N ICK LE FLUSH HANDLE MIN 800 GRAM MAP RATING , MAINLINE ML170 PLASTIC OPEN FRONT SEAT. WATER CLOSET - KOHLER SAN SOUCI, K-5172, ELON GATED, WHITE VITREOUS CHIN A, 16.5" TALL, ADA, 1.28 GPF, 12" ROUGH-IN, LH/RH SELECTED BY PC AT ORDERING, SATIN N ICK LE FLUSH HANDLE MIN 800 GRAM MAP RATING , MAINLINE ML170 PLASTIC OPEN FRONT SEAT. URINAL - KOHLER BARDON, K-4991-ET, TOP SPUD, WHITE VITREOUS CHINA, WALL HUNG, WASH-OUT, MOEN COMMCERCIAL FLUSH VALVE, 8312,01 25, 0.125 G ALLO N/FLUSH. UR-2 SHA LL BE MOUN TED AT ADA HEIGHT. LAVATORY - N AMEEK'S SCARABEO, 8047/D-80 BATHROOM SINK, 32" X 20" O.D., 28.7" X 12.8" X 5.3" D EEP BOWL, ADA, WALL MOUNT, WHITE VITREO US CHINA, SINGLE HOLE - KOHLER K-13468 ELECTRONIC FAUCET, (0.5 GP M), SINGLE HOLE, AC POWERED. PC TO PROVID E SINGLE SUPPLY TRAN SFORMER AT INDIVIDUAL RESTROOMS/MULTI-OUTLET AT RESTROOM G ROUPS, WITH GRID STR AINER, 1.5" PVC P-TRAP, CHR OME STO PS AND SUPPLIES, MAINLINE PLASTIC INSULATION PACKAGE FOR ADA PROTECTION, WITH TMV-1. LAVATORY - N AMEEK'S SCARABEO, 8047/D-80 BATHROOM SINK, 32" X 20" O.D., 28.7" X 12.8" X 5.3" D EEP BOWL, ADA, SEMI-RECE SSED COUN TER MOUNT, WHITE VITREOUS CHINA, SINGLE HOLE - KOHLER K-13468 ELECTRONIC FAUCET, (0.5 G PM), SINGLE HOLE, AC P OWERED. PC TO PROVIDE SINGLE SUP PLY TRANSFORMER AT IN DIVID UAL RESTROOMS/MULTI-OUTLET AT R ESTROOM GR OUPS, WITH GRID STRAIN ER, 1.5" PVC P-TRAP, CHROME STOPS AND SUPPLIES, MAIN LINE PLASTIC IN SULATION PACKAGE FOR ADA PROTECTION, WITH TMV-1. MOP SERVICE BASIN - FIAT MOLDED STO NE, MODEL MSBID2424, 24x24", IN TEGRAL DR AIN WITH STRAINER, FIAT MODEL 830-AA SERVICE FAUCET, 8" CEN TERS, IN TEGRAL VACUUM BR EAKER AND STOPS. FLOOR DRAIN - ZURN ZN-415B, CAST IRON BODY, FLASHING COLLAR, 5" DIAMETER NICKEL BR ONZE STRAINER, ADJUSTABLE HEAD HEIGHT, P ROSET OR SURE SEAL FLEXIBLE ELASTOMER IC SELF-CLOSING TRAP SEAL - SEE PLAN FOR DRAIN SIZE FLOOR SINK - ZURN Z1930, 8"X4" CAST IRON BODY, ACID RESISTING EPOXY COATED INTERIOR , BO TTOM DOME STRAINER, 1/2 GRATE - SEE PLAN FOR PIPE SIZE G RADE CLEANOUT - ZURN CO-2448, ADJUSTABLE HEIGHT PVC RISER, CAST IRON FRAME AND COVER, PVC BODY FLOOR CLEANOUT - ZURN ZN1400, CAST IRON BODY, NICKEL BRON ZE HEAD ASSEMBLY, ADJUSTABLE HEAD, GAS AN D WATERTIGHT ABS TAPERED THREAD PLUG - SEE PLAN FOR PIPE SIZE WALL CLEANOUT - ZURN Z-1469 COVER PLATE, POLISHED 304 STAINLESS STE EL, PVC PIPE CLEANOUT - SEE PLAN FOR PIPE SIZE THERMOSTATIC MIXING VALVE - LEONARD 170, 0.375" INLET AND OUTLETS, MIN 0.5 G PM, MAX 3 GPM FLOW AT 20 PSI PRESSURE DROP , BRASS BODY CONSTRUCTION, FIELD TEMPERATURE ADJUSTABILITY, CHECK STOPS, SET FOR 110° F DISCHAR G E TEMPERATURE, ASSE 1070 AIR ADMITTANCE VALVE - STUDOR MIN I VENT 20301, PVC, WITH SCREEN , LIFETIME WARRANTY - SEE PLAN FOR PIPE SIZE ROOF DRAIN - ZURN Z-100, 15" O.D. CAST IRON BO DY, P LASTIC DO ME, UNDERDECK CLAMP, MEMBRANE CLAMP, ADJUSTABLE HEIGHT, ROOF SUMP RECEIVER OVERFLOW ROOF DRAIN - ZURN Z-100, 15" O.D. CAST IRON B ODY, CAST IRON DOME, UNDERDECK CLAMP, MEMBRANE CLAMP, ADJUSTABLE HEIGHT, ROOF SUMP RECEIVER, 2" INTERNAL DAM ROOF HYDRAN T - WOOD FO RD RHY1-MS, FREEZELESS, 48 1/2" OVERALL LENGTH, 1" INLET, 3/4" BRASS NOZZLE, VACUUM BREAKER, RH-MS MOUNTING KIT, 1/8" DRAIN PIPED TO NEAREST DRAIN WITH AIR GAP DRINKING FOUNTAIN (HIGH/LOW) - ELKAY EZSTLD D, ADA, RIGHT AND LEFT SIDE CLOSING P USH BUTTONS, GALVANIZED FRAME, STAINLESS STEEL BASIN, GRAY SHROUD, 1.5" P-TRAPS, CHROME STOPS AN D SUPPLIES POTABLE WATER HEATER - BO CK, 100HEC-300, TANK TYPE WATER HEATER, 300 MBH INPUT, 97.0% EFF, 100 G ALLON STORAG E, 335 GALLON PER HOUR RECOVERY AT 100°F RISE, 4" PVC FLUE AND CA PIPING. POTABLE EXPAN SION TANK - WATTS PTL-35, IN-LINE, 14 GALLON TOTAL, 5.6 G ALLON ACCEP TAN CE, NSF APPRO VED. AREA D RAIN - ZURN ZN-415B, CAST IRON B ODY, FLASHING COLLAR, 5" DIAMETER N ICKEL BRONZE STRAINER, ADJUSTABLE HEAD HEIG HT, PROSET OR SURE SEAL FLEXIBLE ELASTOMERIC SELF-CLOSIN G TRAP SEAL - SEE PLAN FOR DRAIN SIZE. POTABLE PUMP - TACO LOADMATCH PUMP, LF1130, 15 GPM, 15' HEAD , 1/8 HP, 120/60/1, ALL BRONZE WET ROTOR CIR CULATOR - CONTR OLLED BY AQ UASTAT. POTABLE PUMP - TACO 008-BF, 1.5 GPM, 12' HEAD, 1/25 HP, 120/60/1, ALL BRONZE WET ROTOR CIRCULATOR - CONTROLLED BY 24V TIME CLOCK. STORAGE TANK - RHEEM RUUD, COMERCIAL VERTICAL STORAGE TANK, ST120A, 120 G ALLON, ASME, 150 P SI MAX WORKING PRESSURE, MIN IMUM 2" RIGID POLYURETHANE FOAM INSULATIO N. WC-1 WC-2 UR-1 LAV-1 LAV-2 MSB-1 FD-1 FS-1 GCO-1 FC0-1 WCO-1 TMV-1 AAV-1 RD-1 ORD-1 RH-1 DF-1 PWH-1 PWH-2 PET-1 AD-1 PP-1 PP-2 ST-1 PLUMBING FIXTURE SCHEDULE: SUMP PUMP - ZOELLER 49, SIMPLEX P UMP SYSTEM, (1) CAST IRON PUMP, SUBMERSIBLE, 1.5" DISCHARGE PIPE, 10 GPM AT 15' HEAD, 120/60/1, 1/4 HP MOTOR, 3-WIRE CORD AND PLUG WITH FLOAT ALARM, 24"x84" FIBERGLASS B ASIN WITH C OVER. SP-3 30"Ø BASIN SCALE: DUPLEX SUMP PUMP DETAIL NONE PVC OR STAINLESS STEEL PIPE FLOAT SUPPORTS MINIMUM "OFF" LEVEL "ON" LEVEL PUMPS ALTER NATE OP ERATION EACH CYCLE MAXIMIZE BASED ON D EPTH AND VOLUME OF BASIN SUMP PUMP, TYP. FLOAT SWITCH, TYP. VENT HOLE, TYP. 4" INLET 4" INLET 4" DISCHARGE P IPE GATE VALVE, TYP. CHECK VALVE, TYP. SUMP COVER WITH GASKETED PIPE OPENINGS 4 FLOAT SYSTEM ALARM BELL "ON " BO TH PUMPS ALREADY ACTIVATED SET AB OVE OVERRIDE AND B ELOW INLET 2" VENT CONTINUED RE: PLANS 4" W CO DISCONNECT PO WER SUPP LY CONTROL & ALARM POWER SUPPLY (SINGLE PHASE ONLY) ALARM LIGHT ELECTRICAL ALTERNATOR CONTROL PANEL GAS METER LOAD SCHEDULE DF-1 250 MBH 284 CFH DF-2 300 MBH 341 CFH (NEW ADDITIO NAL LOAD) TOTAL GAS LOAD 2,922 MBH 3,322 CFH DF-3 350 MBH 398 CFH RTU-1 125 MBH 142 CFH PWH-1 300 MBH 341 CFH PWH-2 300 MBH 341 CFH (F)KITCHEN 1,098 MBH 1,249 CFH B-1 199 MB H 226 CFH PLUMBING FIXTURE SCHEDULE: SUMP PUMP - ZOELLER 1 37, SIMPLEX PUMP SYSTEM, (1) CAST IRON PUMP, SUBMERSIBLE, 1.5" DISCHARGE PIPE, 50 GPM AT 17' HEAD, 120/60/1, 10.7 AMPS, WITH FLOAT ALARM, 30"x36" FIBERGLASS BASIN WITH HEAVY DUTY COVER, PROVIDE EXTENSION RINGS AS REQUIRED . - NOTE: O NLY FIBERGLASS BASIN SHALL BE PROVIDED AND INSTALLED DURING THIS PHASE. PUMP SPECIFICATION IS PROVIDED FOR REFERENCE ONLY. SUMP PUMP - ZOELLER 137, DUPLEX PUMP SYSTEM, (2) CAST IRON PUMPS, SUBMERSIBLE, 1.5" DISCHARGE PIPE, 50 GPM AT 17' HEAD, 120/60/1, 10.7 AMPS, WITH FLOAT ALARM, 30"x36" FIBERGLASS BASIN WITH HEAVY DUTY COVER, PROVIDE EXTENSION RINGS AS REQUIRED . - NOTE: O NLY FIBERGLASS BASIN SHALL BE PROVIDED AND INSTALLED DURING THIS PHASE. PUMP SPECIFICATION IS PROVIDED FOR REFERENCE ONLY. GREASE INTERCEPTOR - COLORADO PRECAST, 1,250 G ALLON 6" CONCRETE WALLS, 8" CONCRETE LID, #4 REBARD THROUGHOUT, (2) FROSTPROOF, AIR TIGHT, H20 MANHOLE COVERS WITH EXTENSIO N RIN GS AS REQUIRED FOR FLUSH COVER INSTALLATION, UNIT SHALL BE SUITABLE FOR HEAVY VEHICLE LOADING, DESIGN SHALL MEET CITY STANDARDS. OIL IN TERCEPTOR - ZURN Z-1186, 30 GALLON CAPACITY, 50 GALLON FLOW RATE, 3" INLET AND OUTLET PIPE CONNECTIO NS.ACID RESISTANT COATED INTERIOR/EXTERIOR, SECURED G ASKETED N ON-SKID COVER. SP-1 SP-2 GI-1 OI-1 NOTE: THE EQUIPMENT LISTED UNDER THIS PORTION OF THE FIXTURE SCHEDULE WAS SPECIFIED AN D PROVIDED DURING THE F&F PACKAGE PHASE OF CONSTRUCTION. THIS EQUIPMENT IS SHOWN HERE FOR CLARIFICATION ON LY. G AS PRESSURE REDUCING VALVE SCHEDULE - PRV-1 PR OVIDE AND INSTALL MAXITROL 325-5L, WITH SPRING FOR 14" W.C. INLET, 7" W.C. OUTLET PRESSURE - WITH VENT LIMITER - 3/4" OR 1" AS NEEDED - 425 MBH MAXIMUM LARGEST AP PLIANCE SERVED BY REGULATOR, 600 MBH MAXIMUM TOTAL LOAD OF MULTIPLE APPLIANCES. PROVIDE REGULATOR AT EACH PIECE OF GAS FIRED EQUIPMENT, OR PIPE (1) REGULATOR TO MULTIPLE PIECES OF EQUIPMEN T AS SIZE ALLOWS. SCALE: POTABLE WATER HEATER DETAIL NONE CW HW CW CW HWC HW HW HW CW CW G G G G GG CW THIS DETAIL REPRESENTS APPROXIMATE INSTALLATION REQUIREMENTS, NOTES ARE TYPICAL FOR EACH WATER HEATER - ALWAYS FOLLOW MANUFACTURER'S IN STALLATION INSTRUCTION S 4" PVC COMBUSTION AIR AND FLUE ROUTED UP THROUGH CHASE TO ROOF TOTAL PIPE LENG TH (FLUE+CA) SHALL BE 110'-0" EQUIVALENT LENGTH PWH-1 PWH-2 POTABLE EXPANSION TANK, PET-1 CHECK VALVE, TYP. POTABLE PUMP, PP-1 TACO 009-BF, 5GPM AT 20 FEET HEAD, 120/60/1, 1 /25 HP. ON/OFF BY TIME CLOCK 1.25" 1.5" 1.5" 1" POTABLE WATER HEATER, SET TEMPERATURE AT 140°F 1.5" HW & CW CONN ECTIO NS TO EQUIPMENT SHALL BE MADE USING HEAT TRAP NIPPLES DI-ELECTRIC UNION , TYP. GAS COCK, TYP. FULL SIZE, 6" DIRT LEG 4" FD-1 DR AIN VALVE, TYP. T & P VALVE, TYP. PIPE DRAIN FULL SIZE TO FLO OR DRAIN WITH AIR-G AP UN ION, TYP. 0.5" 1.5"0.75" 1" 1.5" 1.5" Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P6.1 PL U M B I N G S C H E D U L E S AN D D E T A I L S JKM 1/23/2017 TMS STANLEY PARK PAVILION ESTES PARK, CO 15-053 2 1 2 2 2 2 13 FEB 2017 48"Ø BASIN SCALE: DUPLEX GREASE SUMP PUMP DETAIL NONE PVC OR STAINLESS STEEL PIPE FLOAT SUPPORTS SUMP PUMP, TYP. FLOAT SWITCH, TYP. 4" INLET 2" DISCHARG E PIPE G ATE VALVE, TYP. SUMP COVER WITH GASKETED PIPE OPENING S 2" VENT CONTINUED RE: PLANS 4" W CO DISCON NECT POWER SUPPLY CONTROL & ALARM POWER SUPPLY (SINGLE PHASE O NLY) ALARM LIGHT ELECTRICAL ALTER NATOR CONTROL PANEL V Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P6.2 GR E A S E P U M P SY S T E M S C H E D U L E S AN D D E T A I L S Author 1/23/2017 Checker STANLEY PARK PAVILION ESTES PARK, CO 15-053 GP-1 2 13 FEB 2017 SCALE: SNOWMELT PIPING - STAIR INSTALLATION DETAIL NONE BOILER SCHEDULE NUMBER MAKE & MODEL NUMBER REMAR KS B-1 RHEEM RTGH-95DVLN 1 WITH FACTOR Y SUPPLIED RELIEF VALVE 1199 MBH INPUT MBH OUTPUT 187 FLUID 40% PG VENT SIZE 3"Ø CA SIZE 3"Ø % EFF 94% ELEC DATA 120/1 FLA - HEIGHT (IN) 28" WIDTH (IN) 18.5" DEPTH (IN) 10" WEIGHT 80 2 3 4 2 110°F EWT AND 140°F LWT 3 PVC VENTING WITH CONCENTRIC VENT KIT 4 RATED AT 7,600' ELEVATION PUMP SCHEDULE NUMBER MAKE & MOD EL NUMBER REMARKS P-1 TACO - 0011-F4 P-2 TACO - 2400-50-3P TYPE SERVICE IMP. DIA.FLUID GPM HEAD (FT.) % EFF BHP HP ELEC DATA RPM WEIGHT IN-LINE IN-LINE B-1 SNO WMELT - - 40% P G 40% PG 5 9 12 38 - - -1/8 1/2 120/1 120/1 3,250 3,450 12 16- SNOWMELT MANIFOLD SCHEDULE NUMBER MAKE & MODEL NUMBER REMAR KS MAN-1 WIRSBO/UPON OR 1 COPPER SUPPLY AND RETURN MANIFOLDS 313 41,629 25 1 AREA (SF) TOTAL HEAT (BTUH) 6" O.C. TUB E SPACIN G APP ROX LOOP LENGTH FT (EA.) 18.7 HEAD LOSS/ LOOP (FT)#LO OPS 3 FLUID 40% PG 1/2" TUBIN G SIZE (IN ) TOTAL HEAD LOSS (FT) 3 GPM/ LOOP TOTAL FLO W (G PM) 9 2 2 1/2" PEX TUBING 250 2 HORIZONTAL SLAB AND VERTICAL STAIR IN STALLATION 3 SYSTEM DESIGN ACCOUNTS FOR: 1. MIN. R-10 INSULATION BELOW - 2. 130°F EWT, 115° LWT (AT PIPE) - 3. 40% PROPELYNE GLYCOL - 4. 7,600' ELEVATION SCALE: SNOWMELT TUBING DETAIL NONE COMPACTED GRADE MINIMUM 1.5" CONCRETE COVER ABOVE TUBING P EX TUBING ATTACHED TO REBAR WITH WIRE TIES, TYP. REBAR/WIRE MESH RIG ID SLAB INSULATION MIN. R-10 RIG ID EDGE INSULATION MIN. R-10 SCALE: SNOWMELT TUBING DETAIL AT CONTROL JOINT NONE SECURE TUBIN G TO REBAR 6" ON EACH SIDE OF CONTR OL JOIN T PEX TUBING COMP ACTED GRADE CON CRETE RIGID SLAB INSULATION MIN. R-10 REBAR/WIRE MESH CON TROL JOINT SLEEVE Air Comfort, inc. Heating and Air Conditioning Service Refrigeration Commercial New Construction Geothermal Remodel 150 Rome Ct Fort Collins, CO 80524 (970) 490-1458 Fax (970) 490-1462 22 3 L i n d e n S t . , S u i t e 2 0 4 Fo r t C o l l i n s , C O 8 0 5 2 4 Ph o n e : 9 7 0 - 5 5 6 - 0 5 7 0 Fr o n t - d e s k @ i n t - m e c h . c o m DRAWN BY: CHECKED BY: JOB N UMB ER: DATE: FILE NAME:R-15-053-M001 P6.3 SN O W M E L T SC H E D U L E S A N D DE T A I L S Author 1/23/2017 Checker STANLEY PARK PAVILION ESTES PARK, CO 15-053 0' SNOWMELT BOILER SCHEMATIC NO SCALE 2 13 FEB 2017