Loading...
HomeMy WebLinkAboutPACKET Town Board Study Session 2024-01-23 January 23, 2024 5:00 p.m. — 6:45 p.m. Board Room IPTOWN BOARD 4:45 p.m. Dinner ® STUDY SESSION AGENDA ACCESSING MEETING TRANSLATIONS (Accediendo a las Traducciones de la Reunion) To access written translation during the meeting, please scan the QR Code or click �•• this link for up to 48 other languages (Para acceder a la traduccion durante la reunion, par favor escanee el cOdigo QR o haga clic en el enlace para hasta 48 • : •! idiomas mas): Cr 1. rA.•r https://attend.wordly.ai/join/FLUL-1105 •. '�` Choose Language and Click Attend(Seleccione su lenguaje y haga clic en asistir) Use a headset on your phone for audio or read the transcript can assist those having difficulty hearing (Use un auricular en su telefono para audio o lea la transcripcion puede ayudar a aquellos que tienen dificultades para escuchar). No public comment will be heard This study session will be streamed live and available on the Town YouTube page at www.estes.org/videos 5:00 p.m. Focus on Museum Collections Care: Planning for the Future. (Director Fortini) 5:35 p.m. Updated ADA Transition Plan. (Manager Schumaker) 6:05 p.m. Property Tax Work-Off Program. (Town Administrator Machalek) 6:20 p.m. VEP Earth Day Festival. (VEP Director Oppermann & VEP Manager Paiement) 6:35 p.m. Trustee & Administrator Comments & Questions. 6:40 p.m. Future Study Session Agenda Items. (Board Discussion) 6:45 p.m. Adjourn for Town Board Meeting. Informal discussion among Trustees concerning agenda items or other Town matters may occur before this meeting at approximately 4:30 p.m. Page 1 i� f A fP TOWN OF ESTES PARI Report To: Honorable Mayor Koenig Board of Trustees Through: Town Administrator Machalek From: Derek Fortini, Estes Park Museum Director Date: January 23, 2024 RE: Focus on Museum Collections Care: Planning for the Future Purpose of Study Session Item: The Estes Park Museum, in coordination with Town Administration, has developed annual strategic initiatives since 2016. This organic, internal document outlines annual goals while balancing ongoing scope of services based on current resources. Although we may not achieve every goal for various reasons, the document guides staff toward achieving the mission of the Museum, which is to conduct activities that preserve, share, and respect the unique history of Estes Park. The 2024 Strategic Initiatives focuses on collections, the foundation of the Estes Park Museum. We wanted to bring this to the attention of the Town Board because the shift in focus will result in some noticeable changes in our scope of services for the year. Our intention tonight is to inform the Board of the proposed changes, the reasoning behind them, how they will be financially supported (especially by the Estes Park Museum Friends & Foundation), and invite feedback/questions. Town Board Direction Requested: Provide feedback on the Museum's proposed refocus on collections care for 2024. Present Situation: Some important aspects of collections care have been deferred for a number of years at the Estes Park Museum for a variety of reasons. The main reason is that staff has had to prioritize other more public initiatives or have been unable to reasonably process materials because of the sheer volume of items in the Museum's collection. The Estes Park Museum did not have a position focused solely on collections care until 2013. This was short-sighted, as our collection is the foundation of the Museum's mission and what makes it unique. With over 35,000 historic artifacts in the collection, a better approach to maintaining and fully understanding, caring for, and making accessible the collection would be to have one staff member for every 10,000 artifacts. This ratio aligns with the best standards and practices for the make-up of the Museum collection. With a position focused on collections for the past 10 years, an entire collections facility move in 2019, and an inventory of artifacts, the collection is currently in its best state in Page 3 the Museum's 62 years of existence. However, the collection continues to need a lot of attention and must become a priority so that our progress can continue. One of the largest outlying goals yet to be achieved that impedes progress and takes up physical space within the Museum Annex facility is the backlog of large donations. In 2013, there was a large family donation of artifacts related to local Joe Mills who was instrumental in various aspects of the development of Estes Park (see publication: Joe Mills of Estes Park:A Colorado Life by Dr. James H. Pickering). This donation has been further added to with another family donation of artifacts, which they were unaware of having in 2013, donated in 2023. In 2016, the Estes Valley Library District transferred its entire local history collection to the Museum. This included vertical files, postcards, various local non-profit organizational history (such as Woman's Club and Newcomer's Club), and a number of other items. While the goal was to be able to transfer the material database to database, this is not possible and each item needs to be individually referenced against the current Museum collection, catalogued, housed, and stored. The third major backlog donation originates from 2012 when a department restructuring of the Museum removed a staff member. Many donations were never properly processed due to the workload of processing roughly 100-500 objects donated annually. We feel that now is the time to refocus or we may never be able to catch up. Starting in 2024, we hope to prioritize collections care by taking initial steps to catch up on donations and lay the foundation to better understand and curate the Museum collection. Proposal: While additional resources are needed in collections, there is also a need to generate revenue for the Museum Friends & Foundation under the professionalism of the Museum. To address these issues, we propose the creation of two new term-limited positions, a Collections Assistant and Visitor Coordinator. The Visitor Coordinator position will alleviate day-to-day gallery management from current staff as well as generate revenue for the Museum Friends & Foundation through day-to-day management and development of the membership program and operation of a retail shop. The total cost of the positions is estimated between $104,000 — $118,000 for twelve months. If approved, funding would come from a combination of three budgeted areas: 1) funding from already approved part-time positions, 2) a one-time gift the Museum received in 2023, and 3) a one-time contribution from the Museum Friends & Foundation, which would comprise about 75% of the total cost for the positions. Because of the contributed funding from approved part-time positions and the proposal to refocus resources, the operation of the Historic Fall River Hydroplant and public tours will be impacted in 2024. The Museum Director would manage the full-time Collections Assistant and part-time Visitor Coordinator. The Collections Assistant would work closely with the Curator of Collections to be trained in processing the collections backlog. Upon completion of training, the position will be mostly independent with regular progress reviews with the Curator of Collections and the Museum Director. The Visitor Coordinator would need to receive training from the Museum Friends & Foundation Secretary (who is currently maintaining the membership database) and Curator of Interpretation (who currently oversees day-to-day operation of the Museum gallery and volunteer management). Page 4 Upon completion of training, the Visitor Coordinator would work closely with the Museum Director to further develop volunteer management, the membership program, and implement a shop after the development and acceptance by Administration of a formal business plan. The goal would be to roll out the hiring of these positions shortly after a required budget amendment. The positions will be contracted for an entire year from the start date to fully benefit from their installation and measure impact. This proposal has been reviewed and is supported by Town Administration. The job descriptions have been reviewed and critiqued by Human Resources. A plan of potential payments from the Museum Friends & Foundation to Finance to cover the proposed salaries has been mutually agreed upon. Advantages: Position #1: Collections Assistant - Professionally and properly process three large donation backlogs to completion. - Upon completion, a Collections Plan document can be executed to set the course of collections growth in the future. - The physical storage of the three large donation backlogs within the collection rooms will open-up the flexibility of how processing room space is currently being utilized creating a safer and more efficient environment. - If the backlog is completed early, the position will be used to further implement collection based strategic initiatives. Position #2: Visitor Coordinator - Allows for the Museum Friends & Foundation Board to focus on their annual Museum support through fundraising and advocacy without day-to-day tasks/management. - Create a situation for the Museum Friends & Foundation Board to attain revenue goals (via the further development of the membership program and re-introduction of a shop) and continue to financially support the Museum. - Alleviate the day-to-day gallery and volunteer management of the Curator of Interpretation, allowing them to focus on the development of collection-based programs and exhibits. - Manage the membership database and contribute to a group approach developing the membership program to its full potential under the Museum Director and Museum staff. - Further develop volunteer program/management for gallery allowing current staff to focus on workload/initiatives. Page 5 Disadvantages: - The seasonal Historic Fall River Hydroplant would not have a regular schedule for public access in 2024. The part-time staff funding to assist in its daily operation will be contributed toward the two above positions. The Curator of Interpretation, who usually oversees operation/trains the part-time staff, will need to be involved in implementing members-only programming opportunities that will be instrumental in the recruitment and long-term retention of members. However, the future of this site has been in discussion for a number of years. The Historic Fall River Hydroplant has been operated for over 20 years on minimal resources that continue to decline. There was an insufficient amount of volunteer docents to operate the site in 2023 on a regular basis requiring it to remain closed even when advertised to be open. Discontinuing regularly scheduled open hours at the site will alleviate the responsibility on current resources. The site can still be used to plan events or programs offered to the public or Museum members. - Similarly, the Museum will not be able to offer regularly scheduled Downtown Walking Tours or Birch Ruin/Cabin Tours that have been developing for the past couple of years. Docent numbers to execute such tours, and the time demand upon the Curator of Interpretation to oversee such a service, are no longer viable. However, as with the Historic Fall River Hydroplant, tours may be offered at select times for the public or Museum members. Finance/Resource Impact: #1 Collections Assistant: TP140, 40 hours/week, benefits: $66,763-73,606 #2 Visitor Coordinator: TP140, 28 hours/week, benefits: $37,322-44,787 Total: $104,085-118,393 Financed: Town part-time position (already budgeted): $19,000 Museum one-time gift (2023): $10,000 Estes Park Museum Friends & Foundation, Inc. commitment/donation: $86,000 Total: $115,000 Level of Public Interest Perceived interest level by the public: low to medium interest. Because of the closure of the Historic Fall River Hydroplant and not being able to offer a regular schedule of walking tours, the public may pose some concern. Attachments: None Page 6 A IP TOWN OF ESTES PARI Report PUBLIC WORKS To: Honorable Mayor Koenig Board of Trustees Through: Town Administrator Machalek From: Robert Schumaker Facilities & Parks Manager Greg Muhonen, PE, Public Works Director Date: January 23, 2024 RE: Town of Estes Park Americans with Disabilities Self-Evaluation and Transition Plan Purpose of Study Session Item: Provide an overview of the Town of Estes Park's proposed update to the Americans with Disabilities Act (ADA) Self-Evaluation and Transition Plan (TP). Town Board Direction Requested: Review and provide feedback on the TP document. Confirm the TP is ready for consideration for adoption by the Town Board at a future public meeting. Present Situation: The ADA became effective in July 1990. It sets forth regulations intended to eliminate discrimination against individuals with disabilities, and applies to all state and local governments. Under Title II of the ADA, public entities are required to perform a self- evaluation of their current services, policies, and practices regarding accessibility. Furthermore, a public entity that employs 50 or more people is required to maintain on file, update, and make available the TP for public inspection. The Town of Estes Park's current ADA Self-Evaluation and Transition Plan was originally created and adopted in 1992. It evaluated non-conformities in 25 Town buildings, parking lots and trails. In 2020, the Town Board's Strategic Plan included an Objective to update the TP. The self-assessment of many of the Town's buildings was started by Public Works (PW) Facilities staff, but was not completed. In late 2022, staff hired Mile High Accessibility Consultants, Inc. to complete the assessments of 16 publicly-accessed Town buildings and evaluate the compliance status of Town parks, playgrounds, parking lots, streets, transit stops, and on-street parking areas. This document is the result of that effort. It will give our PW teams guidance for modifications necessary to achieve ADA compliance. Page 7 Proposal: The TP and the supporting technical data attachments are proposed for review and future adoption by the Town Board. The TP is presented in three sections: Facilities, Parks, and Right of Way. Each of these sections identify improvements necessary to comply with the ADA Title II (Public Services) standards. These improvements are prioritized as High, Medium and Low priority work elements which will be reviewed annually to guide updates to the Capital Improvement Plan and budgeting for remedies to the identified Title II violations. Advantages: • Adopting and implementing the corrective work demonstrates the Town's commitment to mobility and meeting Federal and State ADA requirements while protecting the Town from ADA-related litigation and potential loss of Federal funding. • Timely delivery of compliant, accessible buildings, parks, and right of way infrastructure increases access for a broader range of our residents and guests. • A commitment to annual review of the TP allows brings the opportunity to build and refine the TP according to evolving ADA requirements. Disadvantages: • Updating the TP and coordinating the necessary repairs is a a very expensive endeavor that could potentially divert financial resources and Facilities staff time away from the Town's currently outstanding projects and operations; however, correction of many high priority items in the Facilities and Parks categories can be completed by existing staff within 12 months. Finance/Resource Impact: The TP estimates the correction of 1,287 High Medium, and Low priority deficiencies will cost $3,900,820. This initiative will impact multiple Divisions within the PW Department for decades. The number of findings and cost estimate for each main section is as follows: TOTAL ADA FINDINGS (High-Cost Estimates in 2023 Dollars) Location Type High Priority Medium Priority Low Priority Findings Cost Findings Cost Findings Cost Facilities 199 S23,995 255 S438,870 20 S13,150 Parks 62 S8,050 39 S110,650 0 $0 Right-of-way 282 $876,745 392 $2.358,010 4 $400 Transit Stops 5 S1,600 25 S37,600 0 $0 On-street Parking 0 $0 4 S21.500 J $0 Totals 548 $910,390 715 $2.966,630 24 S13,550 Page 8 Removal of ADA barriers in the Town's public infrastructure will require provision of new funding and staff resources over many years. The timeliness and magnitude of the corrective work need to be evaluated annually during the budgeting process. Level of Public Interest The public interest on this topic is low. On November 9, 2023, a public meeting was held in Town Hall to collect input from the community regarding the draft TP. The meeting was attended by Town staff and one non-employee. Attachments: 1. Town of Estes Park ADA Self-Evaluation and Transition Plan 2. Building & Parking Survey 3. Parks & Playgrounds Survey 4. Right of Way & Parking Survey 5. Transit Stops & On-street Parking Survey 6. Presentation Slides Page 9 ; TOWN OF II ESTES PARK :► , COLOIZA 1)O • • • �� ',�`C ..• \, `: ::� iN Nal IL111411 ,,s 'i'•4 .V 4 ESTES PAIN - • tS' . �, l ;ill- I: .. .-4 elil I ' ''' :,i I 4 „ . - ‘ ..: 'I, * i. ;yti . !., ,r, 1 1 ir- - i.- " e4- -- *.< I .‘":?il 'VT.: ,,,,'4 /:::-. 11 !" Ile * '''If ,• ;- - \ '-i ' ,,. ' Sri � ► • ;� yam- � � ,�� 1 i t; )°;. • r lor /i •• -__- ^i fat Self-evaluation and Prepared By : Transition Plan 1 ,,'',4 4 6.., M HAC MILE HIGH ACCESSIBILITY IIIII CONSULTANTS Table of Contents EXECUTIVE SUMMARY 1 ADA SELF-EVALUATION AND TRANSITION PLAN OVERVIEW 6 ESTES PARK ADA SELF-EVALUATION AND TRANSITION PLAN SCOPE 6 ADA SURVEYS OF ESTES PARK OWNED BUILDINGS AND PARKS 7 SURVEY OF ESTES PARK OWNED PUBLIC RIGHTS-OF-WAY 20 TRANSIT STOPS/ON-STREET PARKING FINDINGS SUMMARY REPORTS 27 CONCLUSION 28 APPENDIX A: ADA DEFINITIONS 29 APPENDIX B: GLOSSARY OF TERMS 35 APPENDIX C: ADDITIONAL REPORTS 37 MHAC Executive Summary Town of Estes Park The Town of Estes Park (Town) is a statutory town in Larimer County, Colorado. U.S. Census population estimates as of July 1, 2022, is 5,862. The 2021 Census update identified approximately 11.2 % of Estes Park's population as with a disability, under age 65 years. Introduction to the Americans With Disabilities Act More than 61 million Americans have disabilities. This represents 26% of the U.S. population or 1 in 4 Americans. People with disabilities in Estes Park, like all Americans, participate in a variety of programs, services, and activities provided by the Town. This includes many people who became disabled while serving in the military. Additionally, by the year 2030, approximately 71.5 million baby boomers will be over age 65 and will need services and surroundings that meet their age-related physical needs. People with disabilities have often been excluded from enjoying basic civic activities like using public transportation, serving on a jury, voting, seeking refuge at an emergency shelter, or simply attending their child's or grandchild's school events. The Americans with Disabilities Act (ADA) is a federal civil rights law that prohibits discrimination against people with disabilities. Under the ADA, people with disabilities are entitled to all the rights, privileges, advantages, and opportunities that others have when participating in civic activities. The Americans with Disabilities Act became effective on July 26, 1990, and it extended legislation intended to eliminate discrimination against individuals with disabilities in federally funded facilities under the Rehabilitation Act to all activities of State and local governments regardless of whether these entities receive federal financial assistance. It provides for equal access and equal opportunities for individuals with disabilities to participate in programs, services, and activities provided by public entities such as those offered by the Town of Estes Park. The ADA is divided into five sections, which are referred to as titles. 1. Employment (Title I) Title I requires covered employers to provide reasonable accommodations for applicants and employees with disabilities and prohibits discrimination based on disability in all aspects of employment. Reasonable accommodation includes, for example, restructuring jobs, making worksites and workstations accessible, modifying schedules, providing services such as interpreters, and modifying equipment and policies. 2. Public Services (Title II) Under Title II, public services (which include State and local government agencies) cannot deny services to people with disabilities or deny participation in programs or activities that are available to people without disabilities. In addition, public transportation systems, such as public transit buses, must be accessible to individuals with disabilities. 3. Public Accommodations (Title Ill) Public accommodations include facilities such as restaurants, hotels, grocery stores, retail stores, etc., as well as privately owned transportation systems. Title III requires that all new construction and modifications must be accessible to individuals with disabilities. For existing facilities, barriers to services must be removed if readily achievable. 1 MHAC 4. Telecommunications (Title IV) Telecommunications companies offering telephone service to the public must have telephone relay service to individuals who use telecommunication devices for the deaf(TTYs) or similar devices. 5. Miscellaneous (Title V) This title includes a provision prohibiting either (a) coercing or threatening or (b) retaliating against individuals with disabilities or those attempting to aid people with disabilities in asserting their rights under the ADA. The US Department of Justice (DOJ) revised its regulations implementing the ADA in September 2010. The new rules clarify issues that arose over the previous 20 years and contain new requirements, including the 2010 ADA Standards for Accessible Design (2010 Standards). This document provides general guidance to assist State and local governments in understanding and complying with the ADA's requirements. For more comprehensive information about specific requirements, Estes Park officials and residents can consult the ADA title II regulations, the 2010 ADA Standards for Accessible Design, and the Department of Justice ADA technical assistance publications. ADA and its Relationship to Other Laws Title II of the ADA is companion legislation to two previous federal statutes and regulations, the Architectural Barriers Act (ABA) of 1968 and Section 504 of the Rehabilitation Act of 1973. The Architectural Barriers Act of 1968 is a federal law that requires facilities designed, built, altered, or leased with federal funds to be accessible. The Architectural Barriers Act marks one of the first efforts to ensure access to the built environment. Section 504 of the Rehabilitation Act of 1973 is a federal law that protects qualified individuals from discrimination based on their disability. The nondiscrimination requirements of the law apply to employers and organizations that receive financial assistance from any federal department or agency. Title II of ADA extended this coverage to all State and local government entities, regardless of whether they receive federal funding or not. Federal Accessibility Requirements The US Access Board was established by section 502 of the Rehabilitation Act of 1973 (Rehab Act). The Board consists of 25 total members, 13 of which are appointed by the President from the public and which must be individuals with disabilities. The remaining 12 members are the heads of 12 federal departments and agencies specified by statute, including the heads of the DOJ and the Department of Transportation (DOT). Originally, the Access Board was established to develop and maintain accessibility guidelines for facilities designed, constructed, altered, or leased using federal funds under the Architectural Barriers Act of 1968 (ABA). The passage of the ADA in 1990 expanded the Access Board's responsibilities to "issue minimum guidelines that shall supplement the existing Minimum Guidelines and Requirements for Accessible Design to ensure that buildings, facilities, rail passenger cars, and vehicles are accessible, in terms of architecture and design, transportation, and communication, to individuals with disabilities". The DOJ issues and enforces accessibility standards applicable to facilities subject to ADA title II that are consistent with the "minimum guidelines" issued by the Access Board. The Access Board began revising their 1990 standards in 1994 by establishing an advisory committee composed of members of the design and construction industry, the building code community, and State and local government entities, as well as individuals with disabilities. In 1998, the Access Board added specific guidelines on State and local government facilities and building elements designed for use by children. Other updates to the 1990 ADA Standards have been made with the final version being compiled in the 2004 ADA/ABA Guidelines. The 2004 ADA/ABA Guidelines were the culmination of a long-term effort to facilitate 2 MHAC ADA compliance by eliminating inconsistencies among federal accessibility requirements (ADA &ABA Standards) and between federal accessibility requirements and State and local building codes. In support of this effort, the US DOJ amended its regulation implementing title II and adopted standards consistent with 2004 ADA/ABA Guidelines, naming them the 2010 ADA Standards for Accessible Design. On March 15, 2011, the final rule on the 2010 ADA Standards for Accessible Design became effective to revise the 1990 regulations that implement title II of the ADA that prohibit discrimination based on disability in State and local government services. The final rule was issued to adopt enforceable accessibility standards under the ADA that are more consistent with the minimum guidelines and requirements issued by the Access Board, and to update or amend certain provisions of the title II regulation so that they better reflect the Department's legal and practical experiences in enforcing the ADA since 1991. These new regulations provide a higher degree of clarity to State and local agencies who put forth the effort to comply with the spirit and intent of the ADA. ADA Self-Evaluation and Transition Plan Requirements Title II of the ADA applies to all State and local governments and all departments, agencies, special purpose districts, and other instrumentalities of State or local government ("public entities"). It applies to all programs, services, or activities of public entities, from adoption services to zoning regulation. Title II entities that contract with other entities to provide public services, such as non-profit organizations that operate drug treatment programs, also have an obligation to ensure that their contractors do not discriminate against people with disabilities. Access to civic life by people with disabilities is a fundamental goal of the Americans with Disabilities Act. To ensure that this goal is met, Title II of the ADA requires Estes Park to make its programs and services accessible to people with disabilities. This requirement extends not only to physical access at Estes Park government facilities, programs, and events but also to policy changes that Estes Park must make to ensure that all people with disabilities can take part in, and benefit from, Estes Park programs and services. In addition, Estes Park must ensure effective communication including the provision of necessary auxiliary aids and services so that individuals with disabilities can participate in Estes Park civic activities. ADA Title II Exceptions Title II requires State and local governments to ensure that all their programs, services, and activities, when viewed in their entirety, are accessible to people with disabilities. Program access is intended to remove physical barriers to government services, programs, and activities, but it generally does not require that a State and local government make each facility, or each part of a facility, accessible. For example, each restroom in a facility need not be made accessible. However, signage directing people with disabilities to the accessible features and spaces in a facility should be provided. Program accessibility may be achieved in a variety of ways. State and local governments may choose to make structural changes to existing facilities to achieve access. State and local governments can also pursue alternatives to structural changes to achieve program accessibility. For example, governments can move public meetings to accessible buildings and can relocate services for individuals with disabilities to accessible levels or parts of buildings. When choosing between possible methods of program accessibility, governments must give priority to the choices that offer services, programs, and activities in the most integrated setting possible. In addition, all newly constructed State and local government facilities must be fully accessible to people with disabilities. When programs, services, or activities are in Town facilities, Estes Park must make sure that they are also available to people with disabilities, unless to do so would fundamentally alter a program, service, or activity or result in undue financial or administrative burdens. When a service, program, or activity is in a building that is not accessible, Estes Park can achieve program accessibility in several ways. It can: 3 M HAC • Relocate the program or activity to an accessible facility. • Provide the activity, service, or benefit in another manner that meets ADA requirements. • Make modifications to the building or facility to provide accessibility. Historic Significance The ADA does not require anything that impacts the historic significance of historic property. Historically significant facilities are those facilities or properties that are listed or eligible for listing in the National Register of Historic Places or properties designated as historic under State or local law. Structural changes to these facilities that would threaten or destroy the historical significance of the property or would fundamentally change the program being offered at the historic facility need not be undertaken. Nevertheless, a State or local government must consider alternatives to structural changes in these instances, including using audio-visual materials to depict the inaccessible portions of the facility and other innovative solutions. Technically Infeasible The ADA defines technically infeasible as "something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member that is an essential part of the structural frame or because other existing physical or site constraints prohibit modifications or additions that comply fully with the Standards." Programs and Services Viewed in Their Entirety Title II of the ADA does not require all facilities to be accessible. Programs must be accessible when "viewed in their entirety". A key concept is that public programs and services, when viewed in their entirety, must be accessible to people with disabilities but not all facilities must necessarily be made accessible. For example, if a city or town has multiple public swimming pools and limited resources, it can decide which pools to make accessible based on factors such as the geographic distribution of the sites, the availability of public transportation, the hours of operation, and the programs offered at each site so that the swimming program is accessible to and usable by people with disabilities. Fundamental Alteration of a Service or Program A fundamental alteration is a modification that is so significant that it alters the essential nature of the goods, services, facilities, privileges, advantages, or accommodations offered. If a public entity can demonstrate that the modification would fundamentally alter the nature of its service, program, or activity, it is not required to make the modification. Example: If a city or town requires a 12-foot setback from the curb in the central business district, it may be reasonable to grant a 3-foot variance for a store wishing to install a ramp at its entrance to meet its ADA obligations. If the setback is smaller and the ramp would obstruct pedestrian traffic, granting the variance may "fundamentally alter" the purpose of the public sidewalk. Undue Financial and Administrative Burden An undue burden is described as requiring significant difficulty or expense to make a service or program accessible to people with disabilities. While it is rare that the Town may not be able to provide program access, there are some instances where it is permissible under the ADA. Program access does not require each facility to be made physically accessible in all instances. However, physical accessibility is a requirement for new facilities intended to provide Town programs. The Town is not required to incur an undue financial or administrative burden. If a public entity believes that a modification to a service or program to achieve accessibility would fundamentally alter the service or program or would result in an undue burden, the public entity has the burden of proving that it would result in a fundamental alteration of the service or an undue burden. That decision must be made by the head of the public entity or his or her designee after considering all 4 MHAC the resources available for use in the funding and operation of the service program or activity and must be accompanied by a written statement of the reasons for reaching that decision. Even if there is a conclusion of undue burden, the Town will still need to perform all other remediations that would not result in an undue burden but would improve accessibility to the maximum extent possible. ADA Requirements for the Town of Estes Park Under Title II, Estes Park must meet these general requirements: • Must operate their programs so that, when viewed in their entirety, the programs are accessible to and useable by individuals with disabilities. • May not refuse to allow a person with a disability to participate in a service, program, or activity simply because the person has a disability. • Must make reasonable modifications in policies, practices and procedures that deny equal access to individuals with disabilities unless a fundamental alteration in the program would result. • May not provide services or benefits to individuals with disabilities through programs that are separate or different unless the separate or different measures are necessary to ensure that benefits and services are equally effective. • Must take appropriate steps to ensure that communications with applicants, participants, and members of the public with disabilities are as effective as communications with others. • Must designate at least one responsible employee to coordinate ADA compliance. This person is typically referred to as the ADA Coordinator. The public entity must provide the ADA Coordinator's name, office address, email address, and telephone number to all interested individuals. • Must provide notice of ADA requirements. All public entities, regardless of size, must provide information about the rights and protections of Title II to applicants, participants, beneficiaries, employees, and other interested people. The notice must include the identification of the employee serving as the ADA Coordinator and must provide this information on an ongoing basis. • Must establish a grievance procedure. Public entities must adopt and publish grievance procedures providing for prompt and equitable resolution of complaints. This requirement provides for a timely resolution of all problems or conflicts related to ADA compliance before they escalate to litigation and/or the federal complaint process. Title II of the ADA and its related federal Equal Employment Opportunity Commission (EEOC), DOJ, and DOT regulations link the concepts of discrimination and access which include physical access and program access. Physical Access Physical access requires a facility to be free of barriers preventing participation. Barriers are any obstacles that prevent or restrict access or use of a facility, right-of-way, or park amenity as identified in ADA Title II, Section 35.1492. Program Access Program access is defined by ADA Title II, Section 35.150(a)3. It may include physical accessibility, but also covers policies, practices, communications, and procedures. Program access requires that individuals with disabilities be provided an equally effective opportunity to participate in, or benefit from, programs and services. Program access may be achieved by either structural or non-structural methods. Non-structural methods include acquisition or redesign of equipment, assignment of auxiliary aids and assistance, or provision of services at alternate sites. In general, both may be utilized to ensure program access. Program 5 MHAC access includes advertisement, orientation, eligibility, participation, testing or evaluation, physical access, provision of auxiliary aids, transportation, policies, and communication. Designation of Responsibility In accordance with 28 CFR 35.107(a), Estes Park has designated the following person to serve as ADA Title II Coordinator, to oversee the Town's policies and procedures: Name: Robert Schumaker Title: Facilities & Parks Manager and ADA Coordinator Phone: (970) 577-3576 Email: rchumaker@estes.org Address: 170 MacGregor Ave, Estes Park, CO 80517 ADA Self-evaluation and Transition Plan Overview Under Title II of the ADA, public entities are required to perform a self-evaluation of their current services, policies, and practices regarding accessibility. The goal of the self-evaluation is to verify that, in managing its programs and facilities, Estes Park is providing accessibility and not adversely affecting the full participation of individuals with disabilities. The intent of the ADA self-evaluation is to review Estes Park's entire public program, including all facilities on public property and within public rights-of-way and to identify any obstacles or barriers to accessibility that need to be addressed. The general categories of items to be evaluated include: • Communications, information, and facility signage. • Building Facilities including offices, parks, garages, and other types of buildings. • Pedestrian Facilities (Pedestrian Circulation Routes / Pedestrian Access Routes) including sidewalks, curb ramps, bicycle/pedestrian trails, and traffic control signals that are located within Estes Park's rights-of-way. Public entities are required to provide an opportunity for interested people, including individuals with disabilities or organizations representing individuals with disabilities, to participate in the self-evaluation process by submitting comments. Furthermore, a public entity that employs 50 or more people is required, for at least three years following the completion of the self-evaluation, to maintain on file and make available for public inspection: • A list of the interested people consulted. • A description of areas evaluated, and any problems identified. • A description of any modifications made. Estes Park ADA Self-evaluation and Transition Plan Scope With the help of Mile High Accessibility Consultants (MHAC), the Town of Estes Park has undertaken a comprehensive evaluation of facilities, parks, and the public right-of-way to determine the extent to which individuals with disabilities may be restricted in their access to Town services and activities. Additionally, Estes Park employees reviewed many Town facilities while MHAC surveyed the Town's parks and the public right-of- way. 6 MHAC This document describes the process developed to complete the evaluation of the Town's facilities, parks, and public rights-of-way and presents a Transition Plan for the modification of facilities, parks, and public rights-of way to ensure accessibility. This will help guide the planning and implementation of necessary program and facility modifications over the next 10 years. The ADA Self-evaluation and Transition Plan is significant in that it establishes the Town's ongoing commitment to the development and maintenance of policies, programs, and facilities that include all the Estes Park community. Public Outreach Public input is crucial for the self-evaluation and transition plan process. The ADA regulation requires that State and local governments provide an opportunity for people with disabilities, and other interested individuals or organizations, to review and comment on the self-evaluation and transition plan. This allows for people with disabilities and organizations to contribute to the process of generating accessibility solutions that are more effective and creative. Also, involving the public enhances the accountability of the self-evaluation and transition plan process and helps ensure the prudent use of public resources that are limited. One of the most important benefits of public input is that it can help the Town prioritize the removal of barriers to accessibility that are highly significant to the public. Mile High Accessibility encourages the representation of a diverse range of people with disabilities when possible. This includes people that have physical, visual, hearing, speech, intellectual, learning, behavioral health, and other disabilities, and the organizations that represent people with these disabilities. Mile High Accessibility met with Estes Park staff and key stakeholders during a public meeting on November 9, 2023 to review the draft ADA Self-evaluation and Transition Plan document, identify priorities, and solicit any feedback. Public comments or suggestions will be documented in the final transition plan. Transition Plan Management This Transition Plan is a living document that will continue to be updated as conditions within the Town evolve. The initial schedule is to formally review the complete document (main body and appendices) at least once a year, to identify any need for updates. Updates to the appendices or attachments may be made more frequently as needed. Any substantive updates to the main body of this document should include a public comment period to continue the Town's public outreach efforts. The Town of Estes Park recognizes that ADA compliance is an ongoing responsibility which will require monitoring to discover future accessibility issues that may be encountered. For example, facilities that currently meet ADA requirements could fall out of compliance in the future due to factors such as damage, disrepair, or changes within public rights-of-way that could create new accessibility obstacles. Therefore, the ADA Coordinator will establish an on-going monitoring/inspection program or process to ensure that facilities continue to comply with ADA requirements. Town employees are also encouraged to report any accessibility concerns or deficiencies that they may come across. ADA Surveys of Estes Park Owned Buildings and Parks Estes Park facilities were surveyed by Town employees. MHAC thoroughly reviewed the database and made revisions to conform with the 2010 ADA Standards. MHAC incorporated the Estes Park database into its database format and added cost estimates for each finding. MHAC is highlighting 13 of the public facing facilities from the database provided by Town employees. Although the Town owns many more facilities, the locations highlighted on the following pages are most used by the public and represent the greatest need for evaluation. Mile High Accessibility Facilities and Parks Survey Methodology MHAC used tablet-based technology for facilities, parks, and public right-of-way surveys, data analysis, and reporting. MHAC has provided Site Accessibility Evaluation Reports for each park surveyed along with an 7 Excel ADA Transition Plan Database which is fully searchable and filterable. MHAC Mile High Accessibility surveys facilities for the following for compliance with the ADA: Accessible Routes Site Elements Built-In Elements • Entrance • Parking Spaces • Signage • Parking Facility • Access Aisles • Fire Alarm Systems • Walkways • Passenger Loading Zones • Assistive Listening Devices • Doors • Stairways • Work Surfaces • Doorways • Handrails • Service Counters • Curb Ramps • Ramps • Elevators Plumbing Elements Special Rooms and Spaces Accessibility Elements • Drinking Fountains • Exhibit Areas • Turning Space • Restrooms • Break Rooms • Clear Floor Space • Water Closets • Reception Areas • Changes in Level • Toilet Compartments • Conference Rooms • Reach Ranges • Urinals • Auditoriums • Operable Parts • Lavatories and Sinks • Meeting Rooms • Protruding Objects • Grab Bars • Knee and Toe Clearance Recreation Facilities • Play Areas • Picnic Facilities • Sports Fields and Courts • Swimming Areas • Seating • Shelters Facility and Park Prioritization MHAC assigns a priority of 1 to 3 for each accessibility barrier discovered. The prioritization process is essential so Estes Park can determine what needs to be remediated immediately and what can be delayed until a future date. MHAC priorities are based on the following: 8 MHAC Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Priority 2 — Medium: Should be completed within 24 months to 36 months. Includes barriers that have a lower budgetary impact on the Town in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. It also includes barriers that are a technical violation that is difficult and costly to remediate and may not result in providing greater access to people with disabilities. Includes findings that create a moderate to minimal impact on accessibility compared to the cost of the remediation. Priority 3 — Low: Includes accessibility barriers in employee only spaces. These barriers should be addressed when any employee with a disability requests reasonable accommodations within the employee only space. Probable Construction Costs (Cost Estimates) A probable construction cost estimate range to remediate each barrier was included in MHAC reports and databases. The cost estimate range is based on 2023 dollars. As a high-level summary, the cost estimate for each priority type across all surveyed areas is as follows: TOTAL ADA FINDINGS (High-Cost Estimates in 2023 Dollars) Location Type High Priority Medium Priority Low Priority Findings Cost Findings Cost Findings Cost Facilities 199 $23,995 255 $438,870 20 $13,150 Parks 62 $8,050 39 $110,650 0 $0 Right-of-way 282 $876,745 392 $2,358,010 4 $400 Transit Stops 5 $1,600 25 $37,600 0 $0 On-street Parking 0 $0 4 $21,500 0 $0 Totals 548 $910,390 715 $2,966,630 24 $13,550 Facilities and Parks Transition Plan Databases The Town's Park Facilities and Parks ADA Transition Plan Databases documents facility findings in several formats that allow Town staff a straightforward plan that prioritizes a path to compliance. Each facility and park finding is addressed with a prioritized recommendation that will rectify the barrier. The Transition Plan Database contains: • Finding Number • 2010 ADA Standards Citations • Area Description • Barrier Priority • Latitude and Longitude Coordinates • Cost Estimate Range • Finding Description • Status of Finding (Open/Noncompliant, or Compliant) • As-built Condition • Photograph of Finding • Recommendation and Specifications for Barriers • Notes 9 MHAC FACILITIES ADA FINDINGS SUMMARY ADA HIGH MED LOW LOCATION FINDINGS PRIORITY PRIORITY PRIORITY Broadband Building — 1180 Woodstock Drive 14 9 5 0 Dekker Power—615 Elm Rd 29 13 16 0 Fairgrounds — 1125 Rooftop 160 72 85 3 Hydroplant Museum — 1750 Fish Hatchery Rd 21 8 10 3 Moraine Ave Restroom —215 Moraine Ave 17 5 12 0 Museum — 200 4th St 33 14 18 1 Museum Annex—220 4th St 14 8 6 0 O'Connor Pavilion — 1700 Fish Hatchery Rd 11 4 7 0 Parking Structure 1 — 691 North St. Vrain Ave 8 7 1 0 Town Hall — 170 MacGregor Ave 103 29 62 12 Transit Hub Shelter— 1209 Manford Ave 12 4 8 0 Visitor Center—500 Big Thompson Ave 47 23 23 1 Water Shop — 1360 Brooke Dr 5 3 2 0 TOTAL FINDINGS 474 199 255 20 2023 Dollars Cost Estimates $23,995 $438,870 $13,150 REMAINDER OF PAGE INTENTIONALLY LEFT BLANK 10 MHAC I COST TO REMEDIATE FACILTIES FINDINGS IN 2023 DOLLARS II Cost Estimate Range # of Findings Low High Priority: High 199 $15,170 $23,995 Medium 255 $308,690 $438,87011 Low 20 $8,580 $13,150 11 TOTAL FINDINGS 474 $332,440 $476,015 11 Facility ADA Findings Summary Reports I BROADBAND BUILDING Cost Estimate Range I # of Findings Low High Priority: High 9 $175 $250 11 Medium 5 $2,900 $3,900 Low 0 $0 $0 IITOTAL FINDINGS 14 $3,075 $4,15011 DEKKER POWER AND COMMUNICATION Cost Estimate Range # of Findings Low High Priority: High 13 $575 $925 Medium 16 $13,795 $21,610 Low 0 $0 $0 TOTAL FINDINGS 29 $14,370 $22,535 11 MHAC FAIRGROUNDS Cost Estimate Range II # of Findings Low HighII II Priority: II High 72 $4,150 $6,875 Medium 85 $84,910 $119,480 Low 3 $750 $1,150 ITOTAL FINDINGS 160 $89,810 $127,505 II HYDROPLANT MUSEUM I1 Cost Estimate Range II # of Findings Low High Priority: 1111 High 8 $3,450 $4,700 Medium 10 $11,515 $20,970 Low 3 $2,000 $3,700 IITOTAL FINDINGS 21 $16,965 $29,37011 MORAINE AVENUE RESTROOM Cost Estimate Range # of Findings Low High Priority: High 5 $2,200 $3,000 Medium 12 $16,250 $20,950 Low 0 $0 $0 TOTAL FINDINGS 17 $18,450 $23,950 12 MHAC MUSEUM ANNEX Cost Estimate Range II # of Findings Low HighII 11 Priority: II High 8 $25 $30 Medium 6 $7,700 $11,600 Low 0 $0 $0 ITOTAL FINDINGS 14 $7,725 $11,630 11M II Cost Estimate Range II # of Findings Low High Priority: 1111 High 14 $400 $650 Medium 18 $14,340 $22,120 Low 1 $1,000 $1,500 IITOTAL FINDINGS 33 $15,740 $24,27011 O'CONNOR PAVILLION Cost Estimate Range # of Findings Low High Priority: High 4 $95 $120 Medium 7 $6,850 $10,700 Low 0 $0 $0 TOTAL FINDINGS 11 $6,945 $10,820 13 MHAC PARKING STRUCTURE 1 Cost Estimate Range # of Findings Low High Priority: High 7 $400 $575 Medium 1 $1,500 $2,500 Low 0 $0 $0 TOTAL FINDINGS 8 $1,900 $3,075 TOWN HALL Cost Estimate Range # of Findings Low High Priority: High 29 $2,750 $5,220 Medium 62 $103,785 $140,980 I' Low 12 $4,530 $6,300 ITOTAL FINDINGS 103 $111,065 $152,500 I TRANSIT HUB SHELTER Cost Estimate Range # of Findings Low High Priority: High 4 $375 $600 Medium 8 $14,000 $19,000 Low 0 $0 $0 TOTAL FINDINGS 12 $14,375 $19,600 14 MHAC VISITOR CENTER Cost Estimate Range # of Findings Low High Priority: High 23 $525 $975 Medium 23 $28,130 $39,040 Low 1 $300 $500 TOTAL FINDINGS 47 $28,955 $40,515 WATER SHOP Cost Estimate Range # of Findings Low High Priority: High 3 $50 $75 Medium 2 $3,015 $6,020 Low 0 $0 $0 TOTAL FINDINGS 5 $3,065 $6,095 REMAINDER OF PAGE INTENTIONALLY LEFT BLANK 15 MHAC 1 PARKS ADA FINDINGS SUMMARY ADA HIGH MED LOCATION FINDINGS PRIORITY PRIORITY Birch Cabin — 355 MacGregor Avenue 0 0 0 Bond Park— 170 MacGregor Avenue 5 3 2 Baldwin Park—271 Ivy Street 4 4 0 Centennial Open Space — East Wonderview Ave 7 5 2 Estes Park Playground— East Riverside Drive 25 17 8 George Hix Memorial — 111 East Riverside Drive 8 4 4 Mrs. Walsh's Garden —West Elkhorn Avenue 3 2 1 Performance Park—435 West Elkhorn Avenue 20 11 9 Thumb Open Space 2 1 1 Tregent Park—219 West Elkhorn Avenue 25 14 11 Women's Heritage Plaza— Riverside Drive 2 1 1 TOTALS 101 62 39 2023 Dollars Cost Estimates $8,050 $110,650 m COST TO REMEDIATE PARKS FINDINGS IN 2023 DOLLARS I Cost Estimate Rangel! # of Findings Low High Priority: High 62 $5,575 $8,050 Medium 39 $69,750 $110,650 TOTAL FINDINGS 101 $75,325 $118,700 16 MHAC Park ADA Findings Summary Reports BIRCH CABIN Due to the location of Birch Cabin and the fact the cabin is on the Historic Registry list and rarely open to public, we recommend providing a virtual tour on the Town's website of the cabin instead of providing an accessible route to the cabin. BOND PARK Cost Estimate Range # of Findings Low High Priority: High 3 $900 $1,250 Medium 2 $1,000 $2,000 Low 0 $0 $0 TOTAL FINDINGS 5 $1,900 $3,250 1 BALDWIN PARK Cost Estimate Range # of Findings Low High Priority: High 4 Maintenance Maintenance Medium 0 $0 $0 Low 0 $0 $0 TOTAL FINDINGS 4 $0 $0 17 MHAC CENTENNIAL OPEN SPACE AT KNOLL WILLOWS Cost Estimate Range # of Findings Low High Priority: High 5 $1,850 $2,550 Medium 2 $4,500 $7,000 Low 0 $0 $0 TOTAL FINDINGS 7 $6,350 $9,550 ESTES PARK PLAYGROUND Cost Estimate Range # of Findings Low High Priority: High 17 $550 $825 Medium 8 $19,250 $32,500 Low 0 _ $0 $0 IITOTAL FINDINGS 25 $19,800 $33,32511 GEORGE HIX MEMORIAL AT RIVERSIDE PLAZA Cost Estimate Range # of Findings Low High Priority: High 4 $825 $1,125 Medium 4 $4,500 $10,750 Low 0 $0 $0 TOTAL FINDINGS 8 $5,325 $11,875 18 MHAC MRS. WALSH'S GARDEN Cost Estimate Range # of Findings Low High Priority: High 2 $500 $750 Medium 1 $2,000 $3,000 Low 0 $0 $0 TOTAL FINDINGS 3 $2,500 $3,750 PERFORMANCE PARK I Cost Estimate Range # of Findings Low High Priority: High 11 $250 $400 Medium 9 $11,000 $15,650 Low 0 $0 $0 I TOTAL FINDINGS 20 $11,250 $16,050 I THUMB OPEN SPACE Cost Estimate Range # of Findings Low High Priority: High 1 $50 $100 Medium 1 $1,500 $2,000 Low 0 $0 $0 IITOTAL FINDINGS 2 $1,550 $2,10011 19 MHAC TREGENT PARK Cost Estimate Range # of Findings Low High Priority: High 14 $650 $1,050 Medium 11 $24,500 $35,750 Low 0 $0 $0 TOTAL FINDINGS 25 $25,150 $36,800 WOMEN'S HERITAGE PLAZA I Cost Estimate Range # of Findings Low High Priority: High 1 Maintenance Maintenance Medium 1 $1,500 $2,000 Low 0 $0 $0 IITOTAL FINDINGS 2 $1,500 $2,00011 Survey of Estes Park Owned Public Rights-of-way Since the adoption of the ADA, Estes Park has endeavored to provide accessible pedestrian features as part of the Town's capital improvement projects. As additional information was made available regarding the methods of providing accessible pedestrian features, the Town updated its procedures to accommodate these methods. Estes Park utilizes two methods for upgrading pedestrian facilities to current ADA and Public Right-of-way Accessibility Guidelines (PROWAG). The first and most comprehensive method is through scheduled street and utility improvement projects. All pedestrian facilities impacted by these projects are upgraded to current ADA and PROWAG accessibility standards and guidelines. The Estes Park goal is to continue to provide accessible pedestrian design features as part of its capital improvement projects. The Town has adopted ADA and PROWAG design standards and procedures. These standards and procedures will be kept current with nationwide and local best management practices. The Town will consider and respond to all accessibility improvement requests. All accessibility improvements that are deemed reasonable will be scheduled consistent with transportation priorities. The Town will coordinate with external agencies to ensure that all new or altered pedestrian facilities within the Town jurisdiction are ADA and PROWAG compliant to the maximum extent feasible. 20 MHAC Maintenance of pedestrian facilities within the public rights-of-way will continue to follow the policies set forth by the Town. Examples of typical maintenance items relating to accessibility include snow removal and ice control for sidewalks, sidewalk repair policy, renewal of crosswalk markings, and signal hardware. Requests for accessibility improvements can be submitted to the ADA Coordinator. Many other agencies are responsible for pedestrian facilities within the jurisdiction of Estes Park. The Town will coordinate with those agencies to assist with identifying and facilitating elimination of accessibility barriers along their routes. Mile High Accessibility surveyed the following public right-of-way elements for compliance PROWAG: • Pedestrian Access Routes • Alternate Pedestrian Access Routes • Curb Ramps and Blended Transitions • Detectable Warning Surfaces • Accessible Pedestrian Signals • Pedestrian Street Crossings • Pedestrian Push Buttons • Passenger Loading Zones For natural surface trails, Mile High Accessibility collected data for the trail head, trail head parking, and trail head amenities. Public Right-of-way Prioritization The prioritization of public right-of-way barriers to accessibility is based on location and access to Estes Park programs and services. With PROWAG and the ADA, there are two categories of barrier removal that are identified in a self-evaluation and transition plan to help prioritize the removal of barriers in the public right-of- way: 1. Public right-of-way barriers which prevent access to local governments' services, programs, and activities, when viewed in their entirety. 2. Public right-of way barriers which were created by new construction or alterations (i.e., new construction of sidewalks and intersections in the public right-of-way built after January 26, 1992), which do not comply with enforceable ADA standards or PROWAG at the time of construction. To help determine when public right-of-way barriers to accessibility should be remediated, the barriers in sidewalks, curb ramps, and shared use paths are prioritized in the following order: A. Arterial roads with access to many programs. B. Collector roads with access to many programs. C. Local roads with access to fewer programs. D. Residential roads and shared use paths with minor access to few programs. E. Little to no access to available programs. Mile High Accessibility assigns the barriers within the above categories a priority level of High, Important, Moderate, and Low, depending on the type of road or public right-of-way, and the type of barrier. In addition to the prioritization based on the type of road and the access to available programs, sidewalk and curb ramp barriers are prioritized by the type of barrier existing in a sidewalk or curb ramp as demonstrated in the tables below. 21 MHAC Sidewalk Barrier Prioritization PRIORITY KEY HIGH MEDIUM LOW Residential Arterial roads Collector roads Local roads with roads/shared use Little to no access Description with access to with access to access to fewer paths with minor to available various programs various programs programs access to few programs programs No curb ramp provided public access route Al-S B1-S Cl-S D1-S El -S Running slope, Cross slope, or Counter slope deficiencies A2-S B2-S C2-S D2-S E2-S Damaged A3-S B3-S C3-S D3-S E3-S Side flares, width, and turning space A4-S B4-S C4-S D4-S E4-S Detectable warning deficiencies A5-S B5-S C5 -S D5 -S E5 -S Vertical discontinuity or various minor deficiencies A6-S B6-S C6-S D6-S E6-S INo deficiencies reported A7-S B7-S C7 -S D7-S E7 -S 22 MHAC Curb Ramp Barrier Prioritization PRIORITY KEY HIGH MEDIUM LOW Residential Arterial roads Collector roads Local roads with roads/shared use Little to no access Description with access to with access to access to fewer paths with minor to available various programs various programs programs access to few programs programs No curb ramp provided public access route Al-CR B1-CR Cl-CR D1-CR El-CR Running slope, Cross slope, or Counter slope deficiencies A2-CR B2-CR C2-CR D2-CR E2-CR Damaged A3-CR B3-CR C3-CR D3-CR E3-CR Side flares, width, and turning space A4-CR B4-CR C4-CR D4-CR E4-CR Detectable warning deficiencies AS-CR B5-CR C5-CR D5-CR E5-CR Vertical discontinuity or various minor deficiencies A6-CR B6-CR C6-CR D6-CR E6-CR 23 MHAC I ESTES PARK STREETS AND PARKING LOTS SURVEYED Big Horn Parking Lot Big Thompson Ave Community Dr E Elkhorn Ave E Riverside Dr Fall River Rd First St Fish Creek Trail Fourth St Lake Shore Dr Trail MacGregor Ave Manford Ave Moraine Ave Moraine Trail N St. Vrain Ave North Court Park Ln Performance Park Parking Lot Post Office Parking Lot Riverside Parking Lot Riverwalk S St. Vrain Ave Second St South Court Spruce Dr Spruce Parking Lot St. Vrain / Big Thompson Ave St. Vrain Ave Trail Stanley Ave Third St Town Hall Plaza Virginia Dr Visitor Center W Elkhorn Ave W Riverside Parking Lot Estes Park Transit Stops and On-street Parking 24 MHAC Public Right-of-way Transition Plan Database The Mile High Accessibility Public Right-of-way Transition Plan Database contains these fields: • Finding Number • PROWAG Guidelines Citations • Area Description • Barrier Priority • Latitude and Longitude Coordinates • Cost Estimate Range • Finding Description • Status of Finding • As-built Condition • Photograph of Finding • Recommendations to Remove Barrier • Notes • Milestone Dates for Barrier Removal REMAINDER OF PAGE INTENTIONALLY LEFT BLANK 25 MHAC Public Right-of-way Summary Reports Street Curb Ramp Curb Ramp Sidewalk Sidewalk Street Street Total - Low Total - High Total - Low Total - High Totals Low Totals High Big Horn Parking Lot $8,600 $10,150 $50 $100 $8,650 $10,250 Big Thompson Ave $21,050 $24,200 $390,850 $511,700 $411,900 $535,900 Community Dr $4,750 $5,500 $6,900 $10,400 $11,650 $15,900 E Elkhorn Ave $10,050 $12,850 $40,475 $61,050 $50,525 $73,900 E Riverside Dr $20,600 $24,400 $9,325 $14,050 $29,925 $38,450 Fall River Rd $0 $0 $121,200 $181,800 $121,200 $181,800 First St $0 $0 $45,600 $45,600 $45,600 $45,600 Fish Creek Trail $1,150 $1,800 $52,200 $78,300 $53,350 $80,100 Fourth St $1,000 $1,500 $4,400 $5,100 $5,400 $6,600 Lake Shore Dr Trail $0 $0 $39,660 $59,540 $39,660 $59,540 MacGregor Ave $350 $400 $9,390 $14,160 $9,740 $14,560 Manford Ave $4,200 $5,050 $250 $300 $4,450 $5,350 Moraine Ave $14,800 $17,200 $35,775 $54,050 $50,575 $71,250 Moraine Ave Trail $700 $800 $44,000 $66,000 $44,700 $66,800 N St.Vrain Ave $13,100 $15,900 $24,250 $36,375 $37,350 $52,275 North Court $0 $0 $45,600 $45,600 $45,600 $45,600 Park Ln $0 $0 $0 $0 $0 $0 Performance Park $5,000 $6,500 $13,345 $19,725 $18,345 $26,225 Post Office Parking Lot $11,700 $14,800 $13,900 $21,000 $25,600 $35,800 Riverside Parking Lot $6,000 $8,000 $7,950 $11,925 $13,950 $19,925 Riverwalk $7,850 $9,900 $46,100 $71,150 $53,950 $81,050 S St.Vrain Ave $59,300 $74,700 $69,750 $104,650 $129,050 $179,350 Second St $0 $0 $52,000 $78,000 $52,000 $78,000 South Court $0 $0 $30,400 $45,600 $30,400 $45,600 Spruce Dr $5,000 $6,500 $7,875 $10,850 $12,875 $17,350 Spruce Parking Lot $1,000 $1,500 $4,350 $6,600 $5,350 $8,100 St.Vrain/Big Thompson $3,000 $3,500 $3,075 $4,650 $6,075 $8,150 St.Vrain Ave Trail $5,600 $6,400 $743,775 $945,700 $749,375 $952,100 Stanley Ave $4,000 $5,000 $21,410 $32,165 $25,410 $37,165 Third St $0 $0 $70,000 $105,000 $70,000 $105,000 Town Hall Plaza $0 $0 $5,200 $7,800 $5,200 $7,800 Virginia Dr $5,350 $6,900 $11,975 $18,000 $17,325 $24,900 Visitor Center $350 $400 $32,600 $47,850 $32,950 $48,250 W Elkhorn Ave $51,900 $66,100 $117,925 $175,700 $169,825 $241,800 W Riverside Parking Lot $0 $0 $9,285 $14,715 $9,285 $14,715 STREET TOTALS 2023 Dollars $266,400 $329,950 $2,130,840 $2,905,205 I $2,397,240 $3,235,155 26 Ae,,, ,,., MHAC PRIORITIZED PUBLIC RIGHT-OF-WAY FINDINGS IN 2023 DOLLARS Priorit Level Findings Total - Low Total - High SIDEWALKS AND CURB RAMPS Al -A3 (High) 164 $382,900 $542,725 B1 - B3 (High) 118 $248,375 $334,020 Cl - C5 (Medium) 24 $28,975 $38,600 D1 - D5 (Medium) 142 $1,623,435 $2,157,740 A4 -A5 (Medium) 115 $60,450 $83,900 B4 - B5 (Medium) 111 $52,905 $78,770 El - E7 (Low) 0 $0 $0 A,B,C,D 6-7 (Low) 4 $200 $400 TRANSIT STOPS High 5 $850 $1,600 Medium 25 $2,650 $37,600 Low 0 $0 $0 ON-STREET PARKING High 0 $0 $0 Medium 4 $21,500 $30,750 Low 0 $0 $0 II Totals _ 712 $2,422,240 $3,305,105 11 Transit Stops / On-street Parking Findings Summary Reports TRANSIT STOPS Ii Cost Estimate Rangel! # of Findings Low Highll Priority: II High 5 $850 $1,60011 Medium 25 $26,250 $37,600 11 Low 0 $0 $0 TOTAL FINDINGS 30 $27,100 $39,20011 27 MHAC ON-STREET PARKING Cost Estimate Range # of Findings Low High Priority: High 0 $0 $0 Medium 4 $21,500 $30,750 Low 0 $0 $0 TOTAL FINDINGS 4 $21,500 $30,750 I Greater detail of transit stops and on-street parking findings can be found in the report listed in Appendix C, item number 4. Conclusion The ADA self-evaluation and transition planning process are vital steps towards creating an inclusive environment for individuals with disabilities. It demonstrates a commitment to equal access and provides a roadmap for necessary improvements and accommodations. By identifying and addressing barriers, the Town of Estes Park can enhance accessibility, promote diversity and inclusion, and ensure compliance with the ADA and PROWAG. Continuously reviewing and updating the ADA Self-evaluation and Transition Plan will help maintain an inclusive environment over time. 28 MHAC Appendix A: ADA Definitions Alterations When a public entity chooses to alter any of its facilities, the elements and spaces being altered must comply with the 2010 Standards. An alteration is defined as remodeling, renovating, rehabilitating, reconstructing, changing, or rearranging structural parts or elements, changing or rearranging plan configuration of walls and full-height or other fixed partitions, or making other changes that affect (or could affect) the usability of the facility. Examples include restriping a parking lot, moving walls, moving a fixed ATM to another location, installing a new service counter or display shelves, changing a doorway entrance, or replacing fixtures, flooring, or carpeting. Normal maintenance, reroofing, painting, wallpapering, or other changes that do not affect the usability of a facility are not considered alterations. The 2010 Standards set minimum accessibility requirements for alterations. In situations where strict compliance with the Standards is technically infeasible, the entity must comply to the maximum extent feasible (see Technically Infeasible below). Auxiliary Aids and Services • Qualified interpreters or other effective methods of making orally delivered materials available to individuals with hearing impairments. • Qualified readers, taped texts, or other effective methods of making visually delivered materials available to individuals with visual impairments. • Acquisition or modification of equipment or devices; and other similar services and actions. Complaint A complaint is a claimed violation of the ADA. Disability • A physical or mental impairment that substantially limits one or more of the major life activities of such an individual. • A record of such impairment; or • Being regarded as having such an impairment. Discrimination Based on Disability • Limit, segregate, or classify a citizen in a way that may adversely affect opportunities or status because of the person's disability. • Limit, segregate, or classify a participant in a program or activity offered to the public in a way that may adversely affect opportunities or status because of the participant's disability. • Participate in a contract that could subject a qualified citizen with a disability to discrimination. • Use any standards, criteria, or methods of administration that have the effect of discriminating based on disability. • Deny equal benefits because of a disability. • Fail to provide reasonable accommodations to known physical or mental limitations of an otherwise qualified individual unless it can be shown that the accommodation would impose an undue burden on the organization's operations. • Use selection criteria that exclude otherwise qualified people with disabilities from participating in the programs or activities offered to the public. 29 MHAC • Fail to use tests, including eligibility tests, in a manner that ensures that the test results accurately reflect the qualified applicant's skills or aptitude to participate in a program or activity. Fundamental Alteration A modification that is so significant that it alters the essential nature of the goods, services, facilities, privileges, advantages, or accommodations offered. If a public entity can demonstrate that the modification would fundamentally alter the nature of its service, program, or activity, it is not required to make the modification. If a public accommodation (private entity) can demonstrate that a modification would fundamentally alter the nature of the goods, services, facilities, privileges, advantages, or accommodations it provides, it is not required to make the modification. Having a Record of Impairment An individual is disabled if he or she has a history of having an impairment that substantially limits the performance of a major life activity; or has been diagnosed, correctly or incorrectly, as having such impairment. Physical or Mental Impairments Physical or mental impairments may include, but are not limited to: vision, speech, and hearing impairments; emotional disturbance and mental illness; seizure disorders; mental retardation; orthopedic and neuromotor disabilities; learning disabilities; diabetes; heart disease; nervous conditions; cancer; asthma; Hepatitis B; HIV infection (HIV condition); and drug addiction if the addict has successfully completed or is participating in a rehabilitation program and no longer uses illegal drugs. The following conditions are not physical or mental impairments: transvestitism; illegal drug use; homosexuality or bisexuality; compulsive gambling; kleptomania; pyromania; pedophilia; exhibitionism; voyeurism; pregnancy; height; weight; eye color; hair color; left-handedness; poverty; lack of education; a prison record; and poor judgment or quick temper if not symptoms of a mental or physiological disorder. Qualified Individual with a Disability A qualified individual with a disability means an individual with a disability who, with or without reasonable modification to rules, policies, or practices; the removal of architectural, communication, or transportation barriers; or the provision of auxiliary aids and services, meets the essential eligibility requirements for the receipt of services or the participation in programs or activities provided by the Town. Reasonable Program Modifications If the individual's disabilities prevent them from performing the essential functions of the program or activity, it is necessary to determine whether reasonable program modifications would enable an individual to perform the essential functions of the program or activity. Reasonable program modification is any change in program or activity or in the way things are customarily done that enables an individual with a disability to enjoy equal program opportunities. Accommodation means modifications or adjustments: • To a registration or application process to enable an individual with a disability to be considered for the program or activity. • To the program or activity environment in which the duties of a position are performed so that a person with a disability can perform the essential functions of the program or activity. • That enables individuals with disabilities to enjoy equally the benefits of the program or activity as other similarly situated individuals without disabilities enjoy. 30 MHAC Modification includes making existing facilities and equipment used by individuals readily accessible and usable by individuals with disabilities. Modification applies to: • All decisions and to the application or registration process. • All services provided in connection with the program or activity. • Known disabilities only. Modification is not required if: • It changes the essential nature of a program or activity of the person with a disability. • It creates a hazardous situation. • Adjustments or modifications requested are primarily for the personal benefit of the individual with a disability. • It poses an undue burden. Regarded as Having a Disability An individual is disabled if she or he is treated or perceived as having an impairment that substantially limits major life activities, although no such impairment exists. Reasonable Modification of Policies and Procedures Many routine policies, practices, and procedures are adopted by public entities without thinking about how they might affect people with disabilities. Sometimes a practice that seems neutral makes it difficult or impossible for a person with a disability to participate. In these cases, the ADA requires public entities to make "reasonable modifications" in their usual ways of doing things when necessary to accommodate people who have disabilities. For example: • A person who uses crutches may have difficulty waiting in a long line to vote or register for college classes. The ADA does not require that the person be moved to the front of the line (although this would be permissible), but staff must provide a chair for him and note where he is in line, so he does not lose his place. • A person who has an intellectual or cognitive disability may need assistance in completing an application for public benefits. • A public agency that does not allow people to bring food into its facility may need to make an exception for a person who has diabetes and needs to eat frequently to control his glucose level. • A city, town, or county ordinance that prohibits animals in public places must be modified to allow people with disabilities who use service animals to access public places. (This topic is discussed more fully later.) • A city, town, or county ordinance that prohibits motorized devices on public sidewalks must be modified for people with disabilities who use motorized mobility devices that can be used safely on sidewalks. Only "reasonable" modifications are required. Any modification that would result in a "fundamental alteration" or a change in the essential nature of the entity's programs or services is not required. 31 MHAC Safe Harbor The requirements in the 2010 ADA Standards are, for many building elements, identical to the 1991 Standards and the earlier Uniform Federal Accessibility Standards (UFAS). For some elements, however, the requirements in the 2010 Standards have changed. For example: • The 1991 Standards allowed light switches, thermostats, and other controls to be installed at a maximum height of 54 inches. Under the 2010 Standards, the maximum height is 48 inches. • The 1991 Standards required one van-accessible space for every eight accessible spaces. The 2010 Standards require one van-accessible space for every six accessible spaces. • The 2010 Standards for assembly areas contain revised requirements for dispersion of accessible seating, sightlines over standing spectators, and companion seating. If a facility was in compliance with the 1991 Standards or UFAS as of March 15, 2012, a public entity is not required to make changes to meet the 2010 Standards. This provision is referred to as the "safe harbor." It applies on an element-by-element basis and remains in effect until a public entity decides to alter a facility for reasons other than the ADA. For example, if a public entity decides to restripe its parking lot (which is considered an alteration), it must then meet the ratio of van accessible spaces in the 2010 Standards. The 2010 Standards also contain requirements for recreational facilities that were not addressed in the 1991 Standards or UFAS. These include swimming pools, play areas, exercise machines, court sport facilities, and boating and fishing piers. Because there were no previous accessibility standards for these types of facilities, the safe harbor does not apply. The program access rules apply, and the 2010 Standards must be followed when structural change is needed to achieve program access. Service Animals Under the ADA, a service animal is defined as a dog that has been individually trained to do work or perform tasks for an individual with a disability. The task(s) performed by the dog must be related to the person's disability. For example, many people who are blind or have low vision use dogs to guide and assist them with orientation. Many individuals who are deaf use dogs to alert them to sounds. People with mobility disabilities often use dogs to pull their wheelchairs or retrieve items. People with epilepsy may use a dog to warn them of an imminent seizure, and individuals with psychiatric disabilities may use a dog to remind them to take medication. Dogs can also be trained to detect the onset of a seizure or panic attack and to help the person avoid the attack or be safe during the attack. Under the ADA, "comfort," "therapy," or"emotional support" animals do not meet the definition of a service animal because they have not been trained to do work or perform a specific task related to a person's disability. Allowing service animals into a "no pet" facility is a common type of reasonable modification necessary to accommodate people who have disabilities. Service animals must be allowed in all areas of a facility where the public is allowed except where the dog's presence would create a legitimate safety risk (e.g., compromise a sterile environment such as a burn treatment unit) or would fundamentally alter the nature of a public entity's services (e.g., allowing a service animal into areas of a zoo where animals that are natural predators or prey of dogs are displayed and the dog's presence would be disruptive). The ADA does not override public health rules that prohibit dogs in swimming pools, but they must be permitted everywhere else. The ADA requires that service animals be always under the control of the handler and be harnessed, leashed, or tethered, unless these devices interfere with the service animal's work or the individual's disability prevents him from using these devices. Individuals who cannot use such devices must maintain control of the animal through voice, signal, or other effective controls. Public entities may exclude service animals only if 1) the dog is out of control and the handler cannot or does not regain control; or 2) the dog is not housebroken. If a service animal is excluded, the individual must be allowed to enter the facility without the service animal. 32 MHAC Public entities may not require documentation such as proof that the animal has been certified, trained, or licensed as a service animal, as a condition for entry. In situations where it is not apparent that the dog is a service animal, a public entity may ask only two questions: 1) is the animal required because of a disability? and 2) what work or task has the dog been trained to perform? Public entities may not ask about the nature or extent of an individual's disability. The ADA does not restrict the breeds of dogs that may be used as service animals. Therefore, a town ordinance that prohibits certain breeds must be modified to allow a person with a disability to use a service animal of a prohibited breed, unless the dog's presence poses a direct threat to the health or safety of others. Public entities have the right to determine, on a case-by-case basis, whether use of a particular service animal poses a direct threat, based on that animal's actual behavior or history; they may not, however, exclude a service animal based solely on fears or generalizations about how an animal or breed might behave. The ADA does not require service animals to be certified, licensed, or registered as a service animal. Nor are they required to wear service animal vests or patches, or to use a specific type of harness. There are individuals and organizations that sell service animal certification or registration documents to the public. The Department of Justice does not recognize these as proof that the dog is a service animal under the ADA. Substantial Limitations of Major Life Activities Individuals are disabled if they have a physical or mental impairment that (a) renders them unable to perform a major life activity, or (b) substantially limits the condition, manner, or duration under which they can perform a particular major life activity in comparison to other people. Major life activities are functions such as caring for oneself, performing manual tasks, walking, seeing, hearing, speaking, breathing, learning, and working. In determining whether physical or mental impairment substantially limits the condition, manner, or duration under which an individual can perform a particular major life activity in comparison to other people, the following factors shall be considered: • The nature and severity of the impairment. • The duration or expected duration of the impairment. • The permanent or long-term impact (or expected impact) of or resulting from the impairment. Technically Infeasible Is defined as an alteration that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modifications or additions that comply fully with the Standards. The 2010 Standards also contain an exemption for certain alterations that would threaten or destroy the historic significance of an historic property. Undue Burden The Town of Estes Park shall not provide an accommodation that imposes an undue burden on the operation of the Town's business. An undue burden means significant difficulty or expense incurred in the provision of accommodation. Undue burden includes, but is not limited to, financial difficulty. Undue burden refers to any modification that would be unduly costly, extensive, substantial, or disruptive, or that would fundamentally alter the nature of operation of the business of the Town. Whether a particular accommodation will impose an undue hardship is determined on an individual basis. If a particular modification is determined to cause an undue burden to the Town of Estes, the Town shall attempt to identify another modification that would not pose such a burden. If cost causes an undue burden, the Town must consider whether funding for modification is available from an outside source. If no such funding is 33 M HAC available, the Town must give the person with a disability the opportunity to provide the modification or to pay for that portion of the modification that constitutes an undue burden. REMAINDER OF PAGE INTENTIONALLY LEFT BLANK 34 M HAC Appendix B: Glossary of Terms ABA: See Architectural Barriers Act. ADA: See Americans with Disabilities Act. ADA Transition Plan: Transportation system plan that identifies accessibility needs, the process to fully integrate accessibility improvements, and aims to ensure that all transportation facilities, services, programs, and activities are accessible to all individuals. ADAAG: See Americans with Disabilities Act Accessibility Guidelines. Accessible: A facility that provides access to people with disabilities using the design requirements of the ADA. Accessible Pedestrian Signal (APS): A device that communicates information about the WALK phase in audible and vibrotactile formats. Alteration: A change to a facility in the public right-of-way that affects or could affect access, circulation, or use. An alteration must not decrease or have the effect of decreasing the accessibility of a facility or an accessible connection to an adjacent building or site. Americans with Disabilities Act (ADA): Civil rights legislation passed in 1990 and effective July 1992. The ADA sets design guidelines for accessibility to public facilities, including sidewalks and trails, by individuals with disabilities. Americans with Disabilities Act Accessibility Guidelines (ADAAG): Contains scoping and technical requirements for accessibility to buildings and public facilities by individuals with disabilities under the Americans with Disabilities Act (ADA) of 1990. APS: See Accessible Pedestrian Signal. Architectural Barriers Act (ABA): Federal law that requires facilities designed, built, altered, or leased with federal funds to be accessible. The Architectural Barriers Act marks one of the first efforts to ensure access to the built environment. Capital Improvement Program (CIP): The CIP for a public agency typically includes an annual capital budget and a five-year plan for funding the new construction and reconstruction projects on the agency's transportation system. Detectable Warning: A surface feature of truncated domes, built in or applied to the walking surface to indicate an upcoming change from pedestrian to vehicular way. DOJ: See United States Department of Justice. Federal Highway Administration (FHWA): A branch of the U.S. Department of Transportation that administers the federal-aid Highway Program, providing financial assistance to states to construct and improve highways, urban and rural roads, and bridges. FHWA: See Federal Highway Administration. Pedestrian Access Route (PAR): A continuous and unobstructed walkway within a pedestrian circulation path that provides accessibility. Pedestrian Circulation Route (PCR): A prepared exterior or interior way of passage provided for pedestrian travel. PROWAG: An acronym for the Public Right-of-way Accessibility Guidelines issued in 2005 by the U.S. Access Board. This guidance addresses roadway design practices, slope and terrain related to pedestrian access to walkways and streets, including crosswalks, curb ramps, street furnishings, pedestrian signals, parking, and other components of public rights-of-way. 35 M HAC Right-of-Way: A general term denoting land, property, or interest therein, usually in a strip, acquired for the network of streets, sidewalks and trails creating public pedestrian access within a public entity's jurisdictional limits. Section 504: The section of the Rehabilitation Act that prohibits discrimination by any program or activity conducted by the federal government. Uniform Federal Accessibility Standards (UFAS): Accessibility standards that all federal agencies are required to meet; includes scoping and technical specifications. United States Access Board: An independent federal agency that develops and maintains design criteria for buildings and other improvements, transit vehicles, telecommunications equipment, and electronic and information technology. It also enforces accessibility standards that cover federally funded facilities. United States Department of Justice: Federal executive department responsible for enforcement of the law and administration of justice (also referred to as the Justice Department or DOJ). 36 M HAC Appendix C: Additional Reports Due to the size of the extensive data collected, the files noted in these documents are not directly attached to the ADA Transition Plan but are available from the Town upon request. 1. Facilities ADA Transition Plan Database 2. Parks ADA Transition Plan Database 3. Public Right-of-way Transition Plan Database 4. Transit Stops and On-street Parking Transition Plan Database 5. Parks Site Accessibility Evaluation Reports 37 2020 Town of Estes Park ADA Audit Summary Severity analysis rating: 1.High-A condition which significantly impedes or prohibits the ability of the public to access TOR programs and services. 2.Moderate-A condition which affects the ability of the public to access TOEP programs and services in a minor way or a condition which only affects TOEP staff. Created by:Kasey McMorton 3.Low-A condition which has no effect on the ability of the public to access TOEP programs and services or a condition in which there is only a minor deviation from the requirements of the code. Building Audit Section Location/Area Non-compliant Element Compliance Section Severity Priority In/Out Work Load Corrective Measure (2010 ADA Stadards) House Photo Estimated Cost Timetrame Broadband Building-1180 Parking Lot Main Lot There are 20 parking spaces in the lot with one standard ADA access aisle.This size of lot 502 Medium 1 In Low Woodstock requires a minimum of one ADA access space that is van accessible and marked Pi accordingly. 1 ,,- Add"Van Accessible"sign to ADA access space Broadband Building.1180 Parking Lot Main Lot The ADA access space is not compliant with a cross slope of 1.75%to 2.66%which is over 502.2 High 1 Out Medium Regrade ADA access space so the slope is less than 2%in any direction WIWI Woodstock the 2%maximum r-i.-I- 2 dEn Broadband Building-1180 Parking Lot and Accessible Main Lot The ADA access space and aisle are not connected to the accessible route.There is an 502.3.3 High 1 In and Medium Mark area to connect access aisle with the entry ramp.Regrade this section so the cross slope is less j-nrai Woodstock Route unmarked section 149"long between the aisle and the entry ramp.This section has a Out than 2%while the running slope is less than 5%. . -.An,,. - cross slope up to 2.27%which is over the 2%maximum. 3 -MI Allilliiii Broadband Building-1180 Stairs Main Entry There is a step at the front entry that is questionable.The bottom landing of the step has 403.3,505 High 2 Out Medium Regrade bottom landing so the slope is less than 5%and cross slope is less than 2%.Add ADA -... 'LOT Woodstock a slope of 12.46%-15.3%which is well over the 5%maximum slope for an accessible cmpliant handrails. • Ingel"M---'"-•'..' route There are no handrails present. 4 ....,.rmom. i..._ ' IIIIIIIIIII.L.. Broadband Building-1180 Ramps Main Entry The bottom landing of the entry ramp is not compliant.The length of the concrete 405.7,405.2 High 2 Out Medium Extend the concrete landing to a minimum of 60"with the slope less than 2%in any direction. Woodstock landing is 46"then turns to asphalt with a small hp,less than%".The slope of the concrete is compliant,however,the slope of the asphalt is 2.44%which is over the 2% 5 maximum. • Broadband Building-1180 Entrances Main Entry The main entrance door closes too quickly at 4.2 seconds which is less than the S second 404.2 8,404.2.10 High 2 Oct Medium Remount door so the latch side is on the same side as the entry ramp.Adjust defer se door closes in Woodstock minimum.The door does not have a kickplate present.The entry way is awkward for an 5 second minimum.Add a kickplate to the bottom 10"of the door. accessible approach.The ramp is located on the hinge side of the entry door and requires 6 the user to go around to the other side of the door to open it.There is 93"of maneuvering depth,and 51"from the edge of the open door to the drop off of the patio. Broadband Building-1180 Entrances Main Entry The interior entry door is not compliant.The door closes in 4.5 seconds which is under 404.2.8,404.2.10 High 2 In Low Adjust door closer so door closes in 5 seconds minimum.Add a kickplate to the bottom 10"of the . .. Woodstock the 5 second minimum.There is no kickplate.There is a carpeted mat with rubber edges door.Secure the edges of the rug/mat. inside the door,edges are not secured. -r 7 Broadband Building-1180 Signs Restroom Area The restroom signs are not compliant.The baseline of the lowest character is 40%" 703.4,703.6 Medium 3 In Low Replace signs with ADA complaint ones mounted at the proper ADA height. Woodstock which is less than the 48"minimum.Additionally,the pictogram field is 5 7/8"with 334" figures which is less than the 6"minimum. 8 sf Broadband Building-1180 Water Fountains Restroom Area The wheelchair water fountain is not compliant with a knee height clearance is 26 54" 602.2 High 3 In or Medium Remount the water fountain so there is 27"minimum of knee height clearance. Woodstock which is less than the 27"minimum. Out ibui 9 Broadband Building-1180 Entrances Restroom Area The women's restroom entry door is not compliant.The door width is 30%"which is less 404.2 3,404.2.10 High 3 Out High The entry door width must be 32"minimum when the door is at a 90°angle and measure from the Woodstock than the 32"minimum.There is no kickplate on the door, jamb to the door face.Add a kickplate to the door. 10 Broadband Building-1180 Entrances Restroom Area The men's restroom entry door is not compliant.The door width is 31"which is less than 404.2.3,404.2.10 High 3 Out High The entry door width must be 32"minimum when the door is at a 90°angle and measure from the Woodstock the 32"minimum.There is no kickplate on the door, iamb to the door face.Add a kickplate to the door. 11 Broadband Building-1180 Restrooms Men's and Women's The sinks in both restrooms are mounted too low.The knee height clearance is 26%" 606.2 High 3 In or Medium Remount sinks so the knee height is 27"minimum. Woodstock which is less than the 27"minimum. Out 12 Broadband Building-1180 Restrooms Men's and Women's There is a shelf in each restroom that is not compliant.The women's restroom shelf is 65 603.4 Medium 3 In Low Remove shelves or relocate where they will not protrude in the turning space and are ADA accessible. Woodstock 5/8"in height and protrudes 10 7/8".The men's restroom shelf is 65 7/8"in height and protrudes 10%".ADA compliant shelves have a height of 40 to 48".Protruding object 13 over 4"must be less than 27"or more than 80". Broadband Building-1180 Restrooms Women's The women's restroom rear ADA grab bar is not mounted correctly The bar should be 609.4 Medium 3 In Medium Remount rear grab bar so it has 12"on the closed side and 24"on the open side. Woodstock 12"on the closed side and 24"on the open side.The bar is mounted with 6%"on the closed side and 28%"on the open side 14 Broadband Building-1180 Restrooms Women's The toilet paper dispenser in the women's restroom is located 9 SS"from the front of the 604.7 Low 3 In Medium Remount toilet paper dispenser so the first roll is 7-9"from the front of the toilet. Woodstock toilet. 15 Broadband Building-1180 Restrooms Men's The men's restroom rear ADA grab bar is not mounted correctly.The bar should be 12" 609.4 High 3 In Medium Remount both grab bars.Remount rear grab bar so it has 12"on the closed side and 24"on the open Woodstock on the closed side and 24"on the open side.The bar is mounted with 9"on the closed side.Remount side grab bar so it is 12"from the rear wall for a length of 54"minimum from the rear • side and 27"on the open side.The side ADA grab bar is mounted 11 7/8"from the rear wall. 16 wall which makes the length of the bar from the rear wall 53%"which is less than the 54" minimum. Fairgrounds/Pavilion- Parking Lot Pavilion(West)Lot The parking lot for the Pavilion has two extra ADA parking spots beyond the required 502.2 High 1 In Medium Restripe ADA parking spaces so there is a minimum of one"Van Accessible"space that is 132"wide _ 1115 Rooftop Way two.None are marked as"Van Accessible". with a 60"aisle. - 17 Fairgrounds/Pavilion- Parking Lot Pavilion(West)Lot The east ADA parking space in the Pavilion parking lot is not compliant.The cross slope in 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. t., '7'+M —" � 1115 Rooftop Way the middle and back of the ADA parking space is 3.32%to 7.17%which is over the 2% - maximum 18 /' r gi Fairgrounds/Pavilion- Parking Lot Pavilion(West)Lot The middle east ADA parking space in the Pavilion parking lot is not compliant.The cross 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. — - T T- 1115 Rooftop Way slope in the middle of the ADA parking space is 2,62%which is over the 2%maximum. 19 Fairgrounds/Pavilion- Parking Lot Pavilion(West)Lot The west ADA parking space in the Pavilion parking lot is not compliant.The slope in the 502.4 Medium 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. > � t.— �i. ___ 1115 Rooftop Way middle of the ADA parking space is 2.27%which is over the 2%maximum. , " 20 Fairgrounds/Pavilion- Parking Lot Pavilion(West)Lot The west ADA access aisle in the Pavilion parking lot is not compliant The slope in the 502.4 Medium 1 Out High Regrade ADA access aisle so the slope is less than 2%in any direction. + ---- . 1115 Rooftop Way front and middle of the ADA access aisle is 2.1%to 2.27%which is over the 2%maximum _ The cross slope in the front of the access aisle is 2.1%which is over the 2%maximum. 21 Fairgrounds/Pavilion- Parking Lot Pavilion Dirt Lot North of There are two ADA parking spaces signed on the north side of the Pavilion.These spaces 502.4 Low 1 In Low These spaces are unneeded and would require a lot to get them compliant.They are also not near an 1115 Rooftop Way Building not ADA compliant due to the grounds surface being dirt/gravel and is not considered entrance.Recommend removing the signs. I���Li�s. stable or firm.There is also not access aisle nor any stepping. 22 Fairgrounds/Event Center- Parking Lot Event Center Main Lot The parking lot for the Event Center does not have the adequate amount of ADA parking 208.2 High 1 In High With the current 4 permanent ones being located very far away,recommend adding 7 ADA parking _MIT, 1125 Rooftop Way spaces required.There are 4 spaces on the south side of the parking lot that are quite far and/or spaces closer to the Event Center entrance.Add permanent ADA parking spaces that are compliant from Event Center entrance,There are temporary spaces parallel along the main road by Out and have access aisles.These spaces should be closest to the Event Center entrance as possible. 23 the Event Center entrance,however,none of these have access aisles so they are not compliant. Fairgrounds/Event Center- Parking Lot Event Center Main Lot The west ADA parking space on the south side of the Event Center parking lot is not 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction.Add a compliant ADA _ 1125 Rooftop Way compliant with a slope of 2.62%to 2.8%which is over the 2%maximum.There is no ADA parking space sign, parking space sign. 24 Fairgrounds/Event Center- Parking Lot Event Center Main Lot The middle west ADA parking space on the south side of the Event Center parking lot is 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction.Add a compliant ADA parking 1125 Rooftop Way not compliant with a slope of 2.1%to 3.67%which is over the 2%maximum.There is no space sign - 25 ADA parking space sign. IAN Fairgrounds/Event Center- Parking Lot Event Center Main Lot The middle east ADA parking space on the south side of the Event Center parking lot is 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction.Add a compliant ADA parking 1125 Rooftop Way not compliant with a slope of 2.27%to 3.32%which is over the 2%maximum.There is no space sign. ADA parking space sign. 26 Fairgrounds/Event Center- Parking Lot Event Center Main Lot The east ADA parking space on the south side of the Event Center parking lot is not 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction.Add a compliant ADA parking _ 1125 Rooftop Way compliant with a slope of 3 14%to 3.32%which is over the 2%maximum.There is no space sign. ADA parking space sign. 27 Fairgrounds/Event Center- Parking Lot Event Center Main Lot The west ADA access aisle on the south side of the Event Center parking lot is not 502.4 High 1 Out High Regrade ADA access aisle so the slope is less than 2%in any direction. 1125 Rooftop Way compliant with a slope of 2.1%to 3.84%which is over the 2%maximum. 28WM, Fairgrounds/Event Center- Parking Lot Event Center Main Lot The east ADA access aisle on the south side of the Event Center parking lot is not 502.4 High 1 Out High Regrade ADA access aisle so the slope is less than 2%in any direction. 1125 Rooftop Way compliant with a slope of 2l%to 3.84%which is over the 2%maximum. 29 Fairgrounds/Event Center- Parking Lot Event Center Rooftop The temporary ADA parking spaces that are parallel along Rooftop Way by the entrance 502.2,502.4 High 1 Out and High The parking surface will need to be regraded so the slope is less than 2%in any direction. 1125 Rooftop Way Way to the Event Center are not compliant.None of the ADA parking spaces have permanent In Recommend making these spaces angled to allow for access aisles to be added at each curb ramp. markings or signage.There are no"Van Accessible"spaces marked or sized.Additionally, There will need to be two"Van Accessible"spaces at a minimum.For angled"Van Accessible"spaces, i - __ 30 there are no access aisles present and the curb ramps will become blocked when the the access aisle must be on the passenger side of the ADA parking space.Add permanent striping, spaces are filled.The cross slope of the spaces is 2.62%to 3.14%which is over the 2% markings,and signage that is compliant. maximum.The cross slope along the curb is 5.94%to 10.16%which is over the 2% Ni. Fairgrounds/Grandstands- Parking Lot Grandstands The Grandstands'parking lot has 4 extra ADA spaces than is required.However,none of 208.2,502.2,502.3.3 High 1 In and High Remove the 6 ADA spaces in the middle of the parking lot along with the one in the NE corner. 1209 Manford Ave. them have access aisles and none are compliant due to the slope being over 2% None of Out Regrade the South side of the parking lot so the slope is less than 2%in any direction.There is 27'4" -- the spaces are connected to the accessible route.There are no ADA parking space signs between the south single ADA parking space and the landscaping timber/fence A group of4 ADA . �f - 31 parking alongthpaces(3 regular and l van)with arking spacestwo access fles Add'aI need 45'of n ADA compliant sidewalk(E/W�th along with 36"for a / \sidewalk the east side of the ADA along / the south side of the new ADA parking spaces that connects to a sidewalk(N/S)on the east side of th. new ADA parking spaces and connects to accessible route by the ticket booth via a curb ramp and marked crosswalk.This will result in a compliant number of ADA parking spaces that are connected to the accessible route as required.Add signs for each ADA parking space. Fairgrounds/Pavilion- Accessible Route Pavilion Par 1 along the north side of the Pavilion parking lots not compliant.Due to the curb 403.3 High 1 Out Medium Extend sidewalk width past the curb ramp so there is a sidewalk with a cross slope less than 2%. _ - -- ,r,t y 1115 Rooftop Way amp uumgthe width of the sidewalk,the cross slope supto 7.17%which s over the 2% �;$ - ,`maximum 32 -- Fairgrounds/Pavilion- Accessible Route Pavilion P-ar 2 at the bottom toward the road is non-compliant.The slope of the sidewalk is 403.3,403.4 High 1 Out High This section of the accessible route needs to be regraded and redesigned so that the maximum slope' ''` --- __ 1115 Rooftop Way 6.12%to 7.17%which is over the 5%maximum The cross slope of the sidewalk is up to of the route is 5%and the maximum cross slope is 2%.Make sure there are no vertical changes over I •./3.84%which is over the 2%maximum There is a 3/8"vertical change at the bottom of P- _ 33 a 2 near the truncated domes, Ill ��3i Fairgrounds/Pavilion- Accessible Route Pavilion The crosswalk from P-ar2to P-ar 3 is unmarked and has a non-compliant cross slope. 403.3,502.3.3 High 1 Out Medium Regrade a 36"wide section that connects the curb ramps of P-ar2 and P-ar 3 and stripe as a ®'""" 1115 Rooftop Way The cross slope is 3.67%to 4.72%which is over the 2%maximum crosswalk. ♦ < 34 m m ,14��3,......,_ Fairgrounds/Pavilion- Picnic Tables/Accessible Pavilion-West side The Pavilion picnic table and bench area is not ADA compliant and there are not like 902.2 Medium 3 Out Medium Pave a section of the area with concrete so there is at least one option of each type available that is - 1115 Rooftop Way Route options that are ADA compliant.The ground surface is small gravel rock and is ADA compliant considered unstable and not firm. • - 35 T Fairgrounds/Pavilion- Accessible Route Pavilion P-ar5 has a non-compliant cross slope at the top of the sidewalk toward the road.The 403.3 High 1 Out Low Regrade the top section of the sidewalk so the cross slope is less than the 2%maximum 1115 Rooftop Way cross slope is up to 2.8%which is over the 2%maximum. 36 Fairgrounds/Pavilion- Accessible Route Pavilion P-ar 6 has a cross slope of 2.8%which is over the 2%maximum. 403.3 High 1 Out Medium Regrade sidewalk so the cross slope is less than the 2%maximum `®'" 1115 Rooftop Way A 'N., cox 37 Fairgrounds/Pavilion- Accessible Route Pavilion The crosswalk from P-ar3to P-ar6 is unmarked. 502.33 High 1 In Low Stripe the crosswalk. ®''... 1115 Rooftop Way ,� 38 } .-. m Fairgrounds/Pavilion- Accessible Route Pavilion P-ar 7 has a non-compliant cross slope up to 2.44%which is over the 2%maximum. 403.3 High 1 Out Medium Regrade sidewalk so the cross slope is less than the 2%maximum. ' -., - 1 1115 Rooftop Way I ?:`� - - 39 Fairgrounds/Event Center- Accessible Route Event Center E-ar l and E-ar2 have a non-compliant cross slope of 2.27%which is over the 2% 403.3 Medium 1 Out Medium Regrade this section of the sidewalk so the cross slope is less than the 2%maximum. �G� -1� 1125 Rooftop Way maximum. =\ ®���-mom d 40 ensr Fairgrounds/Event Center- Accessible Route Event Center Ear 4 and E-ar 5 have non-compliant cross slopes up to 3.14%which is over the 2% 403.3 High 1 Out Medium Regrade these sections of sidewalk so the cross slope is less than the 2%maximum. 1125 Rooftop Way maximum. en :... Fairgrounds/Event Center- Accessible Route Event Center E-ar 9 and E-ar 10 have non-compliant cross slopes of 2.10%to 3.14%which is over the 403.3 Medium 1 Out Medium Regrade these sections of sidewalk so the cross slope is less than the 2%maximum. m• - 1125 Rooftop Way 2%maximum - 42 �,-}®®�V Fairgrounds/Event Center- Accessible Route Event Center E-ar 11 has a non-compliant cross slope os 2.1%which is Just over the 2%maximum.The 206.2,403.3 Medium 1 Out High Regrade sidewalk so the cross slope is less than the 2%maximum.ADA requires an accessible route m. _ .S t. 1125 Rooftop Way sidewalk leads to the office door,of which there is no wheel chair access due to steps. for wheelchair to any entrance that is typically used.The events office uses this door for meetings /_. '.w and should be looked at to make ADA wheelchair accessible.Would require replacement of the steps ® � 43 with a ramp and handrails. , ne Fairgrounds/Event Center- Accessible Route Event Center E-ar 12 that connects Barn W'sE-ar 13 to the accessible route and parking lot is non- 402,405 High 1 Out High Add a compliant sidewalk and/or ramp that connected E-ar5to E-ar 13. m. - 1125 Rooftop Way compliant.The slope is up to 14.5%which is over the 5%maximum for the accessible route The surface is also not stable or firm. ' 44 Fairgrounds/Event Center- Accessible Route Event Center E-arl4 is not compliant due to the ground surface not being stable or firm. 302.1 Medium 1 Out Medium Add a sidewalk that is ADA complaint to the north side of Barn W that connects to the accessible ®� _ 1125 Rooftop Way route.Preferably the sidewalk goes away from the building before connecting to the accessible route 5r` - '. toad in emergency situations. \\_ ®., Fairgrounds/Event Center- Accessible Route Event Center The crosswalk across rooftop way by the Event Center entrance is not marked and 502.33 Medium 1 In Medium Stripe the crosswalk. 1125 Rooftop Way therefore is not compliant. 46 - Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 1 has non-compliant cross slope on the south half.The cross slope is 3.67%to 403.3 High 1 Out High Regrade this section of the sidewalk so the cross slope is less than the 2%maximum. ----- 1209 Manford Ave. 5.24%which is over the 2%maximum. lr5 ®m m _ 47 am Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 2 has a non-compliant cross slope of 297%to367%which is over the 2% 403.3 High 1 Out High If keeping middle ADA spaces,need to regrade a section of this route that is 36"wide and has the - e " - 1209 Manford Ave. maximum. cross slope less than the 2%maximum.Also need to stripe the crosswalk. 48 Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 5 has non-compliant cross slope near the restrooms that is 2.27%which is over the 403.3 Medium 1 Out Medium Regrade this section of the sidewalk so the cross slope is less than the 2%maximum. "--r" --- 1209 Manford Ave. 2%maximum. r Q ®®®m® 49 • (\ Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 6 has a noncompliant cross slope of up to 227%which is over the 2%maximum. 403.3 High 1 Out High Regrade this section of the sidewalk so the cross slope is less than the 2%maximum. - "�,a Al* 1209 Manford Ave a ®monm® S, S0 [\ Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 7 has a section that has a non-compliant cross slope of up to 2.27%which is over the 403.3 Medium 1 Out Medium Regrade this section of the sidewalk so the cross slope is less than the 2%maximum. 1209 Manford Ave. 2%maximum ' 1 l4I`'- 51 : Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 8 has a section that has a non-compliant cross slope of up to 2.62%which is over the 403.3,405 High 1 Out High Regrade this section so the cross slope is less than 2%and the slope is less than 5%. `-- -"` �~ 1209 Manford Ave. 2%maximum.The slope sup to 6.82%which is over the 5%maximum.Over 5%must s+ ®m be treated as a ramp and requires handrails and landings. m -m m -- -' R 52 ®.y eas va Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 10 has non-compliant slope and cross slope The slope is up to 577%which is over 403.3 High 1 Out High Regrade G-ar l0 so the slope is less than 5%and the cross slope is less than 2%. �o c r • i 1209 Manford Ave. the 5%maximum The cross slope is up to 4.37%which is over the 2%maximum. r,. m® ® ' , 53 C\ - - . Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 11 hasa non-compliant cross slope that is up to 2.44%which is over the 2% 403.3 High 1 Out Medium Regrade this section so the cross slope is less than 2%. -- -" 1209 Manford Ave. maximum. l cm � ® \® m 54 t+. min®® J Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 12 has a cross slope up to 2.97%and a section that goes up to 6.47%.The maximum 403.3 High 1 Out High Regrade this section so the cross slope is less than 2%. "--- �` 1209 Manford Ave. cross slope is 2%. .f 4mm m ra Fie 55 m m Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 13 hasa non-compliant cross slope that is up to 2.62%which is over the 2% 403.3 Medium 1 Out High Regrade this section so the cross slope is less than 2%. 1209 Manford Ave. maximum. I '� 56 / , Mgt Fairgrounds/Grandstands- Parking Lot Grandstands G-ar lO to G-arl5 is not compliant The slope is as high as 7.52%to 11.4%which is over 403.3 High 1 Out High Regrade this section so the cross slope is less than 2%and the slope is less than 5%. _ 1209 Manford Ave, the 2%maximum The cross slope is up to 2.97%which is over the 2%maximum. m ` m m m 57 m m minGM , Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 16 is not compliant.The slope is up to 5.94%and 15%which is over the 5% 403.3 High 1 Out High Regrade this section so the cross slope is less than 2%and the slope is less than 5%. '- _ --� 1209 Manford Ave. maximum.The cross slopes up to 7.69%wh ch is over the 2%max mum.The surface is also crumbling and has several non-compliant vertical changes. ® P�-. - 58 Fairgrounds/Grandstands- Parking Lot Grandstands G-ar 17 is not compliant with a slope up to 6.29%and a cross slope up to 4.37%which 403.3 High 1 Out Medium Regrade this section so there is a 36"wide pathway that has a cross slope less than 2%and the slope `"`" lign 1209 Manford Ave. are over the 5%and 2%maximum. less than 5%. ®� ® 59 w 4-,I� ........ ♦ .� ... - . mar 7�. Fairgrounds/Grandstands- Parking Lot Fairground Arenas The fairground's arenas are connected by dirt/gravel driving lanes that are uneven and 302.1,402 High 1 Out Very High Install ADA compliant concrete sidewalks that connect from each barn to each stall and form an ADA Y. AM. f, 1209 Manford Ave. are not considered stable or firm and therefore are not ADA compliant. compliant accessible pathway that is similar to the pathway routinely used by fairground users and --- _mot.. guests. - ' ' --. -.-.60 n Fairgrounds/Pavilion- Curb Ramps Pavilion The curb ramp at the bottom of P-ar 2 along the north side of the Pavilion parking lot by 405.2,405.3,406.2, High 1 Out High Redo curb ramp so counter slope is 5%maximum.The curb ramp should have a slope less than 833%7a®++•""'' t1 - 1115 Rooftop Way the road is not compliant The counter slope is 8 92%which is over the 5%maximum. 406.4 and a cross slope less than 2%.The landing should have a slope less than 2%in any direction.Make ® ..�t• The curb rampeis 4.as%t 4.54 whitf iso ert%w%ch ximum.s over hT landing a%n maximum.also The sure any vertical change is less than Y.". Fp ® ' 61 cross slope s4.2%to454%wh ch over the 2%maximum.The land ng's also not j compliant with a slope of 6 12%to 7.17%and a cross slope up to 384%which are over ® _m�� the 2%maximum slope in any direction There sa%"lip at the bottom of the ramp between slabs. Fairgrounds/Pavilion- Curb Ramps Pavilion The curb ramp on the west end of P-ar 3 is not compliant with a cross slope at the top of 405.3,406.3 Low 1 Out High Redo curb ramp so the cross slope is less than 2%and the ramp flares are less than 10%. ""'"' 1115 Rooftop Way the ramp at 21%which is over the 2%maximum.The ramp flares are 12.46%and 16.55%which are over the 10%maximum for flares when a ramp landing is present. . Y 62 if i rID m rID Fairgrounds/Pavilion- Curb Ramps Pavilion The curb ramp and landing on the north side ofPar6 is not compliant.The slope of the 405.2,406.4 Medium 1 Out Medium Redo the curb ramp so the slopes less than the 8.33%maximum.Regrade the landing so the slope is-'•_`''''''‘•''' 1115 Rooftop Way bottom of the curb ramps 8.75%wh ch is over the 8.33%max mum The landing has a less than 2%in any direction. slope of 2.27%to 2.8%which is over the 2%maximum.The cross slope of the landings 63 2.1%to 2.44%which is over the 2%maximum. /- Fairgrounds/Pavilion- Curb Ramps Pavilion The landing for the curb ramp on the south side of P-ar 6 is not compliant.The landing 406.4 Medium 1 Out Medium Regrade the landing so the slope is less than 2%in any direction. C®"""�' 1115 Rooftop Way has a slope of 2.27%to 2.8%which is over the 2%maximum The cross slope of the ♦ .- - landing is 2.1%to 2.44%which is over the 2%maximum. i._i- 641,111 . r• ,, Fairgrounds/Pavilion- Curb Ramps Pavilion The curb ramp on the north side of P-ar 7 and the landing are notcompliant.The cross 405.3,406.4 High 1 Out High Regrade the curb ramp so the cross slope of the ramp is less than 2%.Regrade the landing so the """ 'm++•""'•• - �.i _- 1115 Rooftop Way slope of the curb ramps 2.3%to 2.8%which is over the 2%maximum.The landing has a slope is less than 2%in any direction. AC yam slope of2.97%and the cross slope is 2.1%which is over the 2%maximum. . N. ® sue' 65 - Fairgrounds/Pavilion- Curb Ramps Pavilion The curb ramp on the south side of P-ar 7 by rooftop way is not compliant The counter 406.2,405.3 High 1 Out High Regrade the curb ramp so the counter slope is less than 5%and the cross slope of the ramp is less "'' """""_ 1115 Rooftop Way slope is 7.52%which is over the 5%maximum.The cross slope of the curb ramp is 2.44% than 2%. .,ix, to 2.8%which is over the 2%maximum. �} 66 c� rID ®� Fairgrounds/Event Center- Curb Ramps Event Center The west curb ramp by E-ar4/5 is not compliant.The counter slope is 6.8%which is over 405.2,406.2,406.4 High 1 Out Medium Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp slope is less than m• - 1, 1125 Rooftop Way the 5%maximum.The curb ramp slope is 8.4%to 9.45%which is over the 8.33% 8.33%.Regrade the landing so the slope is less than 2%in any drecton. - -+ �---` maximum.The landing has a slope of 2.44%which is over the 2%maximum. ®04'. "� -. •._-_ 67 ®. �r Fairgrounds/Event Center- Curb Ramps Event Center The middle curb ramp by E-ar4/5 is not compliant.The counter slope is 9.28%which is 405.2,406.2,406.4 High 1 Out Medium Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp slope is less than - , ( t _ 1125 Rooftop Way over the 5%maximum The curb ramp slope is 8.4%which is just over the 8.33% 8.33%.Regrade the landing so the slope is less than 2%in any direction .M - - a maximum.The landing has a slope of 2.62%which is over the 2%maximum. '" 7 '" R�"� 68 -. Fairgrounds/Event Center- Curb Ramps Event Center The east curb ramp by E-ar 4/5 is not compliant.The counter slope is 10.7%which is over 405.2,406.2,406.4 High 1 Out Medium Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp slope is less than m• 1125 Rooftop Way the 5%maximum.The curb ramp slope is up to 10.16%which is over the 8.33% 8.33%.Regrade the landing so the slope is less than 2%in any direction. - r ' maximum.The landing has a slope of 2.8%which is over the 2%maximum. x ®�`� - 69 . ' _ Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp in the middle of E-ar9/10 is not compliant.The counter slope is 9.1% 405.2,406.2,406.4 High 1 Out Medium Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp slope is less than . - - 1125 Rooftop Way which is over the 5%maximum.The curb ramp slope is 93%to 10.16%which is over the 8.33%.Regrade the landing so the slope is less than 2%in any direction - m• -® .P 8.33%maximum.The landing has a slope of 2.62%to 3.84%which is over the 2% "' T_T" 4. 70 maximum. '.�iiia .`� Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp on the south side of E-ar 6 is not compliant.The counter slope is 7.34%to 405.2,406.2 Medium 1 Out Medium Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp cross slope is m♦ 1125 Rooftop Way 9.28%which is over the 5%maximum The cross slope at the bottom of the ramp is 2.8% less than 2%. - r which s over the 2%maximum. � ®�`�� 71 .x ` Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp on the north side of E-ar 7 is not compliant.The slope is up to 8.4%which 405.2,405.3,406.4 High 1 Out and High Redo the curb ramp so the counter slope is less than the 5%maximum and the ramp cross slope is m. - " 1125 Rooftop Way is just over the 8.33%maximum.The cross slope at the top of the ramp is 4.02%which is In less than 2%.Regrade the landing so the slope is less than 2%in any direction.Move the trashcan off- •-® , over the 2%maximum The landing width is reduced by 5"due to a trashcan.The of the sidewalk. ��i®® -72 landing has a slope of 3.84%to 5.94%and a cross slope of 1.92%while the maximum ®.- slope is 2%in any direction. o` Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp on the south side of E-ar 7 is not compliant.The counter slope is 8.22% 406.2,406.4 Medium 1 Out and High Redo the curb ramp so the counter slope is less than the 5%maximum.Regrade the landing so the m. z 1125 Rooftop Way which is over the 5%maximum.The landing width is reduced by 5"due to atrashcan. In slope is less than 2%in any direction.Move the trashcan off of the sidewalk. - _. _z._ The landing has a slope of 3.32%to 4.9%and a cross slope of 2.1%which is over the �:x_® :/`"- -- 73 maximum slope of 2%in any direction. " T"J, Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp on the north side of E-ar 8 is not compliant.The ramp cross slope is 2 97%405.2,406.4 High 1 Out High Redo the curb ramp so the slope is less than the 8.33%maximum and the cross slope is less than the _ -7y 1125 Rooftop Way which is over the 2%maximum.The ramp slope at the very bottom is 12.63%which is 2%maximum.Regrade the landing so the slope is less than 2%in any direction. - - over the 8.33%maximum.The landing has a slope of 3.49%to 3.84%which is over the i' 74 maximum slope of 2%in any direction. Fairgrounds/Event Center- Curb Ramps Event Center The curb ramp on the east end of E-ar9 is not compliant.The counter slope is 7.87% 406.2 Low 1 Out Low Regrade counter slope so it is less than 5%. - 1125 Rooftop Way which is over the 5%maximum. a 75 l Fairgrounds/Event Center- Ramps(Exterior) Event Center The main ramp for the Event center entrance is not compliant.The top section of the 405.3,405.8,405.9 High 1 Out High Redo handrails so they extend 12"minimum beyond the ramp at the top and bottom for non- .---' , ' .•- f--'__MOW c 1125 Rooftop Way ramp has a bottom landing that has a cross slope of 2.27%which is over the 5% switchback handrail sections.Add a curb barrier to the handrail for the flat section of sidewalk. , ® 7,11.- maximum.The left handrail for the short middle section of the ramp extends 4%" - - beyond the ramp bottom which is less than the 12"minimum.The right handrail for the , i x, 76 long middle section of the ramp extends 4%"beyond the ramp bottom which is less than the 12"minimum.The handrails for the bottom section of the ramp extends 4%" 5%" -I beyond the ramp at the top and bottom which is less than the 12"minimum.There is a flat section of sidewalk between the short middle and long middle sections that does not have a curb barrier and has a 17"drop off. Fairgrounds/Grandstands- Stairs Grandstands There is a step located on the east side of the grandstands within G-ar 10 that has a 505.2 Low 2 Out or Medium Add a handrail to the other side at a compliant height of 34-38". 1209 Manford Ave. handrail on one side only. In 77 Fairgrounds/Grandstands- Stairs Grandstands The west section of stairs for the grandstands bleachers has a non-compliant handrail. 505.4,505.10 Medium 2 Out Medium Lower handrail so the height is between 34"and 38"and extends a minimum of one tread depth 1209 Manford Ave. The handrail has a height of 39%"which is over the 38"maximum.The handrail is 4%" beyond the last riser nosing at the bottom. short of the last riser nosing which is less than one tread depth minimum of 14%"-15'''A" 78 beyond the last riser nosing. Fairgrounds/Grandstands- Stairs Grandstands The stairways in the middle of the bleachers are not compliant.The riser heights are not 504.2,505.10 Medium 2 Out or High Adjust the bleachers so the risers and treads are uniform with no more than a%"difference between I -`, __ 1209 Manford Ave. uniform and range from 41/2"up to 53/4".The tread depths range from 14%"to 15 Y." In heights and depths.Add extensions to the top and bottom handrail section so the handrail extends ( I and are not uniform.The handrails do not extend beyond the stars at the top or the one tread depth beyond the last riser nosing at the bottom and 12"past the first riser nosing at the \fh 1 - tr-�f-c 79 oottomi The er handrail 2%e toprt of the last riser nosing at the bottom and is 9%"short top. 1 11 of the first riser nosing at the top. \\\\ Fairgrounds/Grandstands- Stairs Grandstands The stairways in the middle of the bleachers are not compliant The riser heights are not 504.2 Medium 2 Out or High Adjust the bleachers so the risers and treads are uniform with no more than a 34"difference between 1209 Manford Ave. uniform and range from 43/4"up to 51/2".The tread depths range from 147/8"to 15 In heights and depths. 80 %"and are not uniform. I Fairgrounds/Grandstands- Stairs Grandstands The steps for the lowered box areas do not have compliant handrails.The handrails have 505.4,505.10 High 2 Out High Redo the handrails for select boxes so there are ADA compliant stairs to lower boxes that are V. ' --� --- 1209 Manford Ave. a height up to 39"which is over the 38"maximum.The handrails extend up to 4" dispersed throughout the box area. --I Alli "I',, um beyond the last riser at the bottom which is less than the one tread depth , ._.- - ^'- _ - '� 81 minimum.The handrails extend 0"beyond the first riser nosing at the top which is less than the 12"minimum. -" • Fairgrounds/Grandstands- Stairs Grandstands The stairs by the grandstands bleachers west exit are not compliant.The riser heights are 504.2,505.4,505.10 Medium 2 Out High Redo the stairway so the riser heights are uniform.Adjust the handrails so the height is 34-38"and �; �` 4 lr�,`,' 1209 Manford Ave. not uniform ranging from 3%"to7%" The height of the handrail is up to 39%"which is extend 12"beyond the first riser at the top.Add an accessible route at the bottom of the stairs that ' .'.:�.,y over the 38"maximum The left handrail extends only 4"beyond the first riser at the top connects to Barns T and V -_. __ 82 which is less than the 12"minimum.The bottom of the stairs are not connected to an accessible route. Fairgrounds/Grandstands- Stairs Manager's Office The stairs for the Manager's office at the fairgrounds are not compliant.The riser heights 504.2,504.3,505.4, High 2 Out Medium Redo the stairs so the riser heights are uniform and closed.Adjust the handrails so the height is ,_ -- 1209 Manford Ave. range from 6"to7"and are open.The handrails have a height up to 40-48".The right 505.10 between 34"and 38".Extend the right handrail a minimum of 1111"beyond the last riser nosing at C-_-,' !!WAIN., handrail extends 8"beyond the last riser nosing at the bottom which is less than the one the bottom. 83 tread depth minimum of 1115". Fairgrounds/Grandstands- Stairs Exhibitor's Office The stairs for the exhibitors office are not complaint,The stairs are open and should be 504.3,505 Medium 2 In Medium Close in the stairs and add ABA compliant handrails, 1209 Manford Ave. closed There are no handrails present. - 84 i-, Fairgrounds/Grandstands- Stairs Manager/Exhibitor The steps on the east side of the Manager/Exhibitor building that is G-ar16 are not 504.2 Medium 2 Out Medium Replace steps with stairs that have unform riser heights and tread depths.Add ADA compliant 1209 Manford Ave. Building compliant.The riser heights are not uniform at%"to 4"in height.The tread depths are handrails.Or replace steps with a ramp that has ADA compliant handrails and a running slope less .41 not uniform at 41%"to 56%"deep.There are no handrails present. than 10%. - ' 85i' illici' Fairgrounds/Grandstands Stairs and Ground Arenas The arena viewing platforms are raised and have two steps onto the platform area.The 302.3,303.2,402,505 High 2 In High Add ADA compliant ramp and/or stairs to the viewing platforms.Fix the viewing platform surfaces so •,—=._� '•• . _ 1209 Manford Ave Openings steps are missing handrails.The have settled and/or shifted creating large gaps between there are no vertical changes greater then%"and no gaps between board that are greater than M". 'fir,_ < `� • the steps and platform The platforms do not have wheelchair accessibility.The A __\_- ��• 86 platforms have warped boards and gaps that are not ADA compliant 1 Fairgrounds/Grandstands- Bleachers and Ground Arenas The bleachers near the arenas are set on uneven dirt/gravel and do not have any 302.1,802 High 2 Out High Replace bleachers with ADA compliant one that are similar to the grandstands.There should bea 1209 Manford Ave. Surfaces wheelchair space nearby or within. central set of stairs with a handrail and cutouts in the front row for a wheel chair.The surface should - --_ - be concrete that has a slope less than 2%in any direction ands connected to a concrete accessible --- 87 route. Fairgrounds/Pavilion- Entrances Pavilion The Pavilion main entrance door north is not compliant.The door closes from 90-12°in 4 404.2.8 Medium 1 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds. Ai 1115 Rooftop Way seconds which is less than the 5 second minimum. I ; •I 1'I 88 all Fairgrounds/Pavilion- Entrances Pavilion The Pavilion main entrance door south is not compliant The door closes from 90-12°in 3 404.2 8 Medium 1 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds. 1115 Rooftop Way seconds which is less than the 5 second minimum. I gr.!89 � Fairgrounds/Pavilion- Entrances Pavilion The left interior door for the Pavilion main entrance is not compliant.The door closes 404.2.8,404.2.9 High 2 In Medium Adjust closer so door closes from 90-12°in no less than 5 seconds and requires less than 5 pounds of '+�I 1115 Rooftop Way from 90-12°in 3.7 seconds which is less than the 5 seconds minimum.The door requires force to operate. 4„,�y I r P , 18 pounds of force to operate which is over the 5-pound maximum. ��Y ` 90 Fairgrounds/Pavilion- Entrances Pavilion The left interior door for the Pavilion main entrance is not compliant.The door closes 404.28,404.2.9 High 2 In Medium Adjust closer so door closes from 90-12°in no less than 5 seconds and requires less than 5 pounds of 1115 Rooftop Way from 90-12°in 2 7 seconds which is less than the 5 seconds minimum.The door requires force to operate. W. I r • L 16 pounds of force to operate which is over the 5-pound maximum 91 - — i i Fairgrounds/Pavilion- Entrances Pavilion The double doors from the Pavilion lobby to the Arena Area are not compliant.The right 404.2.8,404.2.10 Medium 2 In Medium Adjust closer so door closes from 90-12°in no less than 5 seconds and requires less than 5 pounds of xcs s n 1115 Rooftop Way door closes from 90-12°in 3.5 seconds which is less than the 5 seconds minimum.The force to operate. '�C.I ��!, 410 door requires 12-14 pounds of force to operate which is over the 5-pound maximum. f`ti„i('"�� 92 Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door#2 is not compliant.The door closes from 90-12°in 3 seconds which is 404.28 Medium 2 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds. ir 1115 Rooftop Way less than the 5 second minimum. 93 Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door•3 is not compliant.The door closes from 90-12°in 3.4 seconds which 404.2.4,404.2.8 Medium 2 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds.The push side is compliant and is 1115 Rooftop Way is less than the 5 second minimum.There is 16 1"of maneuvering clearance on the pull an accessible emergency exit,the pull side is not used as an entry so does not need to be addressed. side of the door which is less than the 18"minimum. 94 . Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door#5 is partially compliant.There is 16"of maneuvering clearance on the 404.24 Low 2 N/A N/A The push side is compliant and is an accessible emergency exit,the pull side is not used as an entry so 1115 Rooftop Way pull side of the door which is less than the 18"minimum. does not need to be addressed. 95 Fairgrounds/Pavilion- Entrances Pavilion The Pavilion east exit door is not compliant.The door closes from 90-12°in 4.5 seconds 303.2,404.2.5,404.2.8, High 1 Out and Medium Adjust closer so door closes from 90-12°in no less than 5 seconds.Extend the sidewalk so there is at 1115 Rooftop Way which is less than the 5 second minimum.There is a 3/8"—M"vertical lip on the outside 402.2 In least 36"on the east side of the column and it is connected to the accessible route. \ of the threshold.The exit is not connected to the accessible route due to the column 96 outside of the door reducing the accessible route width to 31"and 26%"which is less than the 36"minimum. Fairgrounds/Pavilion- Entrances Pavilion The interior door of the Pavilion east exit vestibule is not compliant The door closes 404.2 8,404.2.9 High 2 In Medium Adjust closer so door closes from 90-12°in no less than 5 seconds and requires no more than 5 --, ll 1115 Rooftop Way from 90-12°in 3 4 seconds which is less than the 5 seconds minimum.The door requires pounds to operate. - 97 12pounds to operate which is over the 5-pound maximum. r - • Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door 88 is not compliant.The outside maneuvering clearance of the door 404.2.4 Low 2 Out Medium Regrade the maneuvering clearance so it is less than 2%in any direction.Extending it to 18" 1115 Rooftop Way has a slope is 2.8%which is over the 2%maximum.The maneuvering width is 12 M"on minimum past the door edge would be a good idea but is not required.The push side of the door is the pull side due to the edge of the concrete pad. compliant.The door is not connected to any type of accessible route. 98 .—_, Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door#10 is not compliant.The door closes from 90-12°in 4.25 seconds 404.24,404.2.8 Low 2 In Medium Adjust closer so door closes from 90-12°in no less than 5 seconds.The door is not a compliant ADA —. • 1115 Rooftop Way which is less than the 5 second minimum.There is 3 1/2"of maneuvering clearance on emergency exit.Signs should be placed on the door directing to the nearest ADA compliant i In the pull side of the door which is less than the 18"minimum.There is 4 M"of emergency exit. — 99 maneuvering clearance on the push side of the door which is less than the 12"minimum. ' Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door fi11 is notcompliant.The outside maneuvering clearance of the door 404.2.4,404.2.8 Low 2 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds.Extending the outside Ii r-- 'c" '- iskgaW- • 1115 Rooftop Way has a width of 12 M"on the pull side due to the edge of the concrete pad which is less maneuvering clearance to 18"minimum past the door edge would be a good idea but is not required. —1 l than the 18"minimum.The door closes from 90-12°in 3.5 seconds which is less than the The push side of the door is compliant.The door is not connected to any type of accessible route. _ 100 5 second minimum. Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door#12 is not compliant.The outside maneuvering clearance of the door 404.24 Low 1 Out Medium Regrade the maneuvering clearance so it is less than 2%in any direction and extending it to 18" • 1115 Rooftop Way has a slope is 2.8%which is over the 2%maximum. minimum past the door edge would be a good idea but is not required.The push side of the door is rz • '; - 14 compliant.The door is not connected to any type of accessible route. ill' 101 Fairgrounds/Pavilion- Entrances Pavilion The Pavilion door#14 is not compliant.The outside maneuvering clearance of the door 404.24 Low 2 Out Medium Regrade the maneuvering clearance so it is less than 2%in any direction and extending it to 18" 1115 Rooftop Way has a slope is 2.8%which is over the 2%maximum.The maneuvering width is 12 11"on minimum past the door edge would be a good idea but is not required.The push side of the door is the pull side due to the edge of the concrete pad. compliant.The door is not connected to any type of accessible route 102 Fairgrounds/Pavilion- Entrances Pavilion The door to the Pavilion women's restroom is not compliant.The maneuvering width for 404.2.4,404.2.5, High 3 In and Low and Remove water fountains that are between the restroom doors.Bevel the threshold at 1:2.Adjust the 1115 Rooftop Way the push side of the door is 5%"which is less than the 12"minimum.The trashcan on the 404.2.8,404.2.9 Out Medium door closer so the door closes from 90-12°in no less than 5 seconds and requires no more than 5 put side of the door reduces the maneuvering clearance to 1454"which is less than the pounds of force to operate.Move the trashcan away from the door. "1111) - - e 103 18"minimum.The threshold for the doorway is%"and is not beveled.The door closes from 90-12°in 3.8 seconds which is less than the 5 second minimum.The door requires 11 pound to operate which is over the 5-pound maximum. ii srv= Fairgrounds/Pavilion- Entrances Pavilion The door to the Pavilion men's restroom is not compliant.The maneuvering width for 404.2 4,404.2.5, High 3 In and Low and Remove water fountains that are between the restroom doors.Bevel the threshold at 1:2.Adjust the .i— 1115 Rooftop Way the push side of the door is 5"which is less than the 12" The trashcan on the 404.28,404.2.9 Out Medium door closer so the door closes from 90-12°in no less than 5 seconds and requires no more than pull side of the door reduces the maneuvering clearance to 4"which is less than the 18" pounds of force to operate.Move the trashcan away from the door. 104 minimum.The threshold for the doorway is%"and is not beveled.The door closes from ' --- 90-12'in 3.8 seconds which is less than the 5 second minimum.The door requires 11 pound to operate which is over the 5-pound maximum. '- Fairgrounds/Event Center- Entrances Event Center The right set of doors for the Event Center main entrance are not compliant.The right 404.24,404.2.8 Medium 2 In and Low and Adjust the closer so the door closes from 90-12°in no less than 5 seconds.Secured the rug edges to I A�n .® I 1125 Rooftop Way door closes from 90-12°in 3.9 seconds which is less than the minimum of 5 seconds Out High the ground,replace area with carpet squares secured to the ground,or replace with an in-ground slat i Additionally,there is a carpeted rug with rubber edges that does not have secured edges type mat system that is ADA compliant. t'*ilk ' `O Re 105 Fairgrounds/Event Center- Entrances Event Center The left set of doors for the Event Center main entrance are not compliant.The tight 404.2.4,404.2.8 Medium 2 In and Low and Adjust the closer so the door closes from 90-12°in no less than 5 seconds.Secured the rug edges to � 1125 Rooftop Way door closes from 90-12°in 4.5 seconds which is less than the minimum of 5 seconds. Out High the ground,replace area with carpet squares secured to the ground,or replace with an in-ground slat �■y F ` Additionally,the is a carpeted rug with rubber edges that does not have secured edges. type mat system that is ADA compliant. �`-7: 106 Fairgrounds/Event Center- Entrances Event Center The set of doors for the Event Center ADA ramp entrance are not compliant.The right 404.24,404.2.8 High 2 In and Low and Adjust the closer so the door closes from 90-12°in no less than 5 seconds.Secured the rug edges to 1125 Rooftop Way door closes from 90-12°in 4.9 seconds which is less than the minimum of 5 seconds The Out High the ground or replace with an in-ground slat type mat system that is ADA compliant.Regrade the di in :MUM left door has slope of 2.97%on the outside of the door. concrete on the outside of the left door so the slope is less than 2%in any direction. 107 IS MI III 16' Fairgrounds/Event Center- Entrances Event Center The west double doors into the event space are not compliant.The doors require 7 404.2.9 Medium 2 In Low Adjust door closer so doors require less than 5 pounds to operate. ®� r 1125 Rooftop Way pounds of force to operate which is over the 5-pound maximum. ON ' 108 till !I all .. - ' Fairgrounds/Event Center- Entrances Event Center The west double doors into the event space are not compliant.The doors require 8-9 404.2 8,404.2.9 Medium 2 In Low Adjust door closer so doors require less than 5 pounds to operate and closes from 90-12°in no less - ,,, 1125 Rooftop Way pounds of force to operate which is over the 5-pound maximum.Additionally,the right than 5 seconds. ,. door closes from 90-12°in 4.8 seconds which is less than the 5 second minimum. 109 1 Fairgrounds/Event Center- Entrances Event Center The door from the event space to the restrooms is not compliant.The doors require 6 404.2.9 Medium 2 In Low Adjust door closer so doors require less than 5 pounds to operate.The carpet edge is exposed at the 1125 Rooftop Way pounds of force to operate which is over the 5-pound maximum. door threshold.This need to be watched and made sure a tnp hazard/issue does not occur due to • 110 wearing at the edge of the carpet. Fairgrounds/Event Center- Entrances Event Center The Event Center arena door His not a compliant ADA exit.The push side of the door has 404.2 4,404.2.8 High 2 In Low Add sign to door directing to the nearest ADA compliant exit. , 1125 Rooftop Way 11%"of maneuvering width which is less than the 12"minimum required.Additionally, the door closes from 90-12°in 3.2 seconds which is less than the minimum of 5 seconds . 111 ,.mre! p - Fairgrounds/Event Center- Entrances Event Center The Arena double doors C are not ADA compliant and close from 90-12°in 2.9 and 3.6 404.2.8 Medium 2 In Medium Adjust closer so the doors close from 90-12°in no less than 5 seconds.Add ADA emergency exit - -. 1125 Rooftop Way seconds which is less than the 5 second minimum. signage to door. __ - 4_- - 112 Fairgrounds/Event Center- Entrances Event Center Arena door E is not ADA compliant.The door only opens to approximately 80°due to a 404.2 3,404.2.8 High 2 In Low Add sign to door directing to the nearest ADA compliant exit. =iii _ 1125 Rooftop Way structural building obstruction.The door also closes too quickly from 80-12'in 2.5 seconds. j 113 Fairgrounds/Event Center- Entrances Event Center The Arena double doors F are not ADA compliant and close from 90-12°in 4.4 and 3.4 404.2.4,404.2.8 Medium 2 In Low Adjust closer so the doors close from 90-12°in no less than 5 seconds.Add ADA emergency exit --.6` . 1125 Rooftop Way seconds which is less than the 5 second minimum.The outside slope of the left door is signage to door. 2.62%,but is compliant for using the door as an emergency exit. 114 --' I - 0 Fairgrounds/Event Center- Entrances Event Center The east event space restroom's door is not compliant The doors require 82 pounds of 404.28,404.2.9 High 2 In Medium Adjust door closer so doors require less than 5 pounds to operate and closes from 90-12°in no less 1125 Rooftop Way force to operate which is over the 5-pound maximum Additionally,the door closes from than 5 seconds.The concrete before the threshold drops down Y."for4"and creates an awkward 90-12"in 4 seconds which is less than the 5 second minimum. entry for a wheelchair.Grind down edge or fill gap to make it a smoother entry for a wheel chair. 115 Fairgrounds/Event Center- Entrances Event Center The west event space restroom's door is not compliant.The doors require 17 pounds of 404.2.8,404.2.9 High 2 In Medium Adjust door closer so doors require less than 5 pounds to operate and closes from 90-12°in no less 1125 Rooftop Way force to operate which is over the 5-pound maximum.Additionally,the door closes from than 5 seconds.The concrete before the threshold drops down Y."for4"and creates an awkward 90-12°in2.9 seconds which is less than the 5 second minimum. entry for a wheelchair.Grind down edge or fill gap to make rt a smoother entry for a wheel chair. e 116 Fairgrounds/Event Center- Entrances Event Center The left(non-handle)door to the east event space exit hallway is not compliant.The door 404.2 8 Medium 2 In Low Adjust door closer so the door closes from 90-12°in no less than 5 seconds. 1125 Rooftop Way closes from 90-12°in 4.5 seconds which is less than the 5 second minimum. - — • 117 MS Fairgrounds/Event Center- Entrances Event Center The exterior door to the Event Center women's restroom is not compliant.The slope on 404.2.4,404.2.8 High 3 In and Low and Regrade the slope outside of the door so rt is less than 2%in any direction.Adjust door closer so the " 1125 Rooftop Way the outside of the door is 2.1%which is over the 2%maximum.The door closes from 90- Out High door closes from 90-12°in no less than 5 seconds. 12°in 3.7 seconds which is less than the 5 seconds minimum. • 118 Fairgrounds/Event Center- Entrances Event Center The exterior door to the Event Center women's restroom is not compliant.The door 404.28 High 3 In Low Adjust door closer so the door closes from 90-12°in no less than 5 seconds. .34' — 1125 Rooftop Way closes from 90-12°in 3.7 seconds which is less than the 5 seconds minimum. 119 Fairgrounds/Event Center- Entrances Barn W The southwest door of BarnW is not ADA complaint.The slope on the outside of the 404.2.4,404.2.5, High 2 Out High Regrade the slope on the outside of the door so it is less than the 2%maximum.Replace the I,. SI:' 1125 Rooftop Way door is 6.29%which is over the 2%maximum.The threshold of the door is 1"with the 404.2.7 threshold with an ADA compliant one that is IS"maximum with the top Y."beveled 1.2.Replace round I. I top%"beveled.The handle is a round knob which requires grasping to operate. knob handles with lever type handles. - 120 ___-- • Fairgrounds/Event Center- Entrances Barn W The southeast door of Barn W is not ADA complaint.The slope on the outside of the 404.24,404.2.5, High 2 In and Low and Regrade the slope on the outside of the door so it is less than the 2%maximum.Replace the 'WI 1125 Rooftop Way door is 5.59%which is over the 2%maximum.The threshold of the door is 1"with the 404.27,404.2.8 Out High threshold with an ADA compliant one that is%"maximum with the topY."beveled 1:2.Adjust closer ' top%"beveled.The door closes from 90-12"in 2 seconds which is less than the 5 second so the doors close from 90-12"in no less than 5 seconds Replace round knob handles with lever type 121 minimum.The handle is a round knob which requires grasping to operate. handles Fairgrounds/Event Center- Entrances Barn W The southeast door of Barn W is not ADA complaint.The slope on the inside of the door 404.2.4,404.2.5, High 2 In and Low and Regrade the inside of the door so the slope is less than the 2%maximum.Grade the slope and cross 1 _ 1125 Rooftop Way is up to437%which is over the 2%maximum.The slope on the outside of the door is 404.2.7,404.2.8 Out Very High slope on the outside of the door sots less than the 2%maximum.Cover with an ADA complaint - - 4.89%and cros slope is 2 1%which are over the 2%max mum The surfaces dirt and surface such as concrete and connect to an accessible route.Replace the threshold with an ADA - - l ' fl 122 gravel and is not connected to an accessible route.The threshold of the door is 1"with compliant one that is II"maximum with the top Y."beveled 1.2.Adjust closer so the doors close from r"the top%"beveled.The door closes from 90-12°in 2.5 seconds which is less than the 5 90-12°in no less than 5 seconds.Replace round knob handles with lever type handles. - • second minimum.The handle is a round knob which requires grasping to operate. " Fairgrounds/Event Center- Entrances Barn W The southwest door of Barn W is not ADA complaint.The slope on the inside of the door 404.24,404.2.5, High 2 In and Low and Regrade the inside of the door so the slope is less than the 2%maximum.Grade the slope and cross � '"-- 1125 Rooftop Way is up to 2.44%which is over the 2%maximum.The slope on the outside of the door is 404.27,404.2.8 Out Very High slope on the outside of the door so it is less than the 2%maximum Cover with an ADA complaint 18 35%and cross slopes 12.1%which are over the 2%max mum The surface is dirt and surface such as concrete and connect to an accessible route.Replace the threshold with an ADA1116„ 9/ 123 gravel and's not connected to an accessible route The threshold of the doors 1"with compliant one that's%"maximum wth the tap`/."beveled 1:2.Adjust closer so the doors close from the top%"beveled.The door closes from 90 12°in 2 5 seconds which is less than the 5 90-12°in no less than 5 seconds.Replace round knob handles with lever type handles t - second minimum.The handle is a round knob which requires grasping to operate. ' Fairgrounds/Grandstands- Entrances Grandstands The door for the Grandstands concessions entrance is not compliant.The door closes 404.2.8 High 2 In Low Adjust closer so door closes from 90-12°in no less than 5 seconds. - 1209 Manford Ave. from 90-12°in 3.1 seconds which is less than the 5 seconds minimum. I IIiit Fl 124 Fairgrounds/Grandstands- Entrances Grandstands The door for the Grandstands concessions entrance is not compliant.The door closes 404.24,404.2.8 High 2 In and Low and Adjust closer so door closes from 90-12°in no less than 5 seconds.Adjust the counter so there is a ■ i 1209 Manford Ave. from 90-12°in 4 seconds which is less than the 5 seconds minimum.The maneuvering Out Medium minimum of 12"of maneuvering width or add an automatic ADA closer with button. - I� width on the push side is 7%"to 9%,"which is less than the 12"minimum.The slope on ril ". 125 the outside of the door is 454%which is over the 2%maximum for the pull side but is — compliant for the push side of the door. ,- Fairgrounds/Grandstands- Entrances Grandstands The door for the grandstands men's restroom is not compliant.There is 57"of 404.2.4,404.2.8 High 3 Out High Remove wall so there is 60"minimum of maneuvering depth for the pull side of the door.Otherwise, If 1209 Manford Ave. maneuvering depth on the pull side of the door which is less than the 60"minimum.The can add an ADA automatic door opener. door closes from 90-12°in 3.9 seconds which is less than the 5 second minimum. 126 • Fairgrounds/Grandstands- Entrances Grandstands The entrance door to the Grandstands family restroom north is not compliant.The pull 404.2 4,404.2.8 High 3 In Low Remove sign with international symbol of accessibility and replace with one that does not have it. 1209 Manford Ave. side of the door has 6"of maneuvering width,which is less than the 12"minimum,due to The south family restroom will be the accessible one.Otherwise,to make this compliant would need 8- I a fire riser connection.The outside of the door has a slope of 3.1%which is over the 2% to add an automatic door opener to the door and regrade the outside of the door so it is less than 2% ' - ' N'. 127maximum.The door closes from 90-12°in3.9 seconds which is less than the 5 second slope in any direction. mini Fairgrounds/Grandstands- Entrances Grandstands The entrance door to the Grandstands family restroom north is not compliant.The 404.2.4,404.2.8 Medium 3 In and Low and Adjust door closer so door closes in no less than 5 seconds.Regrade the outside of the door so it is 1209 Manford Ave. outside of the door has a slope of 2.44%which is over the 2%maximum.The door closes Out High less than 2%slope in any direction. .t. 'i•.,� from 90-12°in 4.5 seconds which is less than the 5 second minimum. 1 I ' 128 Fairgrounds/Grandstands- Entrances Grandstands The west door of the grandstand bleacher area is not compliant.The door closes from 90-404.28 High 2 In Low Adjust door closer so the door closes from 90-12°in no less than 5 seconds. 1209 Manford Ave. 12°in 2.8 seconds which is less than the 5 second minimum. 129 :`e u . Fairgrounds/Pavilion- Accessible Pathway Pavilion The Pavilion floor mats have flat sides and can separate,this can create 34"to over 3" 302.3,303.2 High 2 In and High Ensure when placing mats for the arena floor that they are as tight as possible and check them daily. 1115 Rooftop Way wide gaps that can be elongated with the dominate direction of travel.The mats are 34" Out If this does not solve the issue,replace the mats with ones that have connecting tabs that holds the thick and create a non-compliant vertical change at the entry to the Pavilion arena space. mats together.Additionally,purchase a couple mats with a beveled edge that has the proper ADA "`- 130 • transition of 1.2 slope that allow compliant access to the arena area when the mats are on the floor. - I Fairgrounds/Event Center- Accessible Pathway Barn W There is a grate in the middle of the floor of Barn W.The openings of the grate are 1" 302.3 High 2 In Medium Replace grate with one that has openings smaller than'k"in any direction. _.�� 1125 Rooftop Way and can be elongated with the directional of travel depending on how Barn W is setup. f77f JJ))11 131 ��11fi,/ I. Fairgrounds/Event Center- Accessible Pathway Barn W There is a non-compliant vertical change by the Barn W volume control knob.The floor 303.2 Medium 4 In Medium Add asphalt to the edge of the foundation to create an ADA compliant threshold to the top of the rl 1125 Rooftop Way has a 1"vertical change between the foundation and the asphalt floor. foundation fora wheel chair operator to use the volume control.OR,move the volume control next I -1 to the audio controls in the Southeast corner of Barn W. C II 132 V Fairgrounds/Event Center- Ramps(Interior) Event Center The Event Center ramp from the lobby to the arena has a non-compliant handrail at the 405.8 Medium 2 Out Medium Extend the ramp handrail a minimum of 12"beyond the ramp bottom. �! 1125 Rooftop Way bottom of the ramp The handrail extends 103/8"beyond the ramp bottom which is less than the 12"minimum. 133 'Fairgrounds/Event Center- Stairs(Interior) Event Center The stairs for the west entrance to the event space from the Event Center lobby has non-505.4 Medium 2 Out Medium Lower handrails so they are within the compliant range of 34-38"as measured from the middle of the`Y' 1125 Rooftop Way compliant handrails.The height of the handrails are 39-41"which is over the 38" stair tread. may.. \ -- _ maximum. 134 Fairgrounds/Event Center- Stairs(Interior) Event Center The stairs for the west entrance to the event space from the Event Center lobby has non-505.4 Medium 2 Out Medium Lower handrails so they are within the compliant range of 34-38"as measured from the middle of the 1125 Rooftop Way compliant handrails.The height of the handrails are up to 42"which is over the 38" stair tread. 135 maximum. Fairgrounds/Event Center- Stairs(Interior) Event Center The main stairs in the Event Center lobby have non-compliant handrails.The height of 505.4 Medium 2 Out Medium Lower handrails so they are within the compliant range of 34-38"as measured from the middle of the !F I iv1125 Rooftop Way the handrails are up to 41"which is over the 38"maximum stair tread. Li 136 Fairgrounds/Event Center- Stairs)Interior) Event Center The stairs in the Event Center from the lobby to the balcony have non-compliant 505.4,505.10 High 2 Out High Lower handrails so they are within the compliant range of34-38"as measured from the middle of the J- 1125 Rooftop Way handrails.The height of the handrails are up to 40"which is over the 38"maximum.The stair tread.Extend the top of the right handrail of the upper section a minimum of 12"beyond the l top of the right handrail of the upper section extends 11 Y."beyond the first riser which is first riser. . 4 137 less than the 12"minimum. Fairgrounds/Event Center- Signs Event Center There is a door by the east event space entrance for the Event Center that leads to the 703 Medium 2 In Low Add ADA compliant signs for this door that has braille and is at an ADA compliant height The arena 1125 Rooftop Way restroom hallway,skipping the lobby.This door is signed with a"Restrooms"sign above side of the door should be labeled"Restrooms"and the restroom hallway side of the door can be —� the door but does not have any signage that can be used by a person with a disability. labeled"Event Space". i i ID 138 The restroom hall side of the door is also unlabeled. '-- Fairgrounds/Grandstands- Signs Grandstands The doors for the concessions have signs above the door ways but no ADA compliant 703 High 2 In Low Add"Concessions Entrance"and"Concessions Exit"signage to both door for the concessions area 1209 Manford Ave. signage. that are on the latch side of the doors and at a compliant height. 139 .1_1r:' Fairgrounds/Grandstands- Signs Grandstands The sign for the grandstands men's restroom has a non-compliant clear floor space with a 703.4 Medium 3 Out Medium Regrade clear floor space so the slope is less than 2%in any direction - kTi 1209 Manford Ave. slope of 2.27%which is over the 2%maximum. f 140 7 Fairgrounds/Grandstands- Signs Grandstands The sign for the grandstands women's restroom has a non-compliant clear floor space 703.4 Medium 3 Out Medium Regrade clear floor space so the slope is less than 2%in any direction. e 1209 Manford Ave. with aslope of 2.79%which is over the 2%maximum. \ 11/1....7.' Gi 141 Fairgrounds/Grandstands- Signs Grandstands The sign for the grandstands family restroom north has a non-compliant clear floor space 703.4 High 3 In Low Replace sign with one that does not have the international symbol of accessibility.This restroom will 1209 Manford Ave. that is blocked by a fire riser connection. not be ADA compliant while the south on will be.142 ' I 3 -1 Fairgrounds/Grandstands- Signs Grandstands The sign for the grandstands family south restroom has a non-compliant clear floor space 703.4 Medium 3 Out Medium Regrade clear floor space so the slope is less than 2%in any direction. --� 1209 Manford Ave. with a slope of 2.27%which is over the 2%maximum. I 1 I 143 fI Fairgrounds/Grandstands- Signs Stanley Park Restroom The sign for the Stanley Park men's restroom is not compliant with no raised letters, 703.2,703.3,703.6 Medium 3 In Low Replace with an ADA compliant sign.Need to add a sign next to entry door as well. — ' 1209 Manford Ave. Building braille,or pictograms 144 ( MEN Fairgrounds/Grandstands- Signs Stanley Park Restroom The sign for the Stanley Park women's restroom is not compliant with no raised letters, 703.2,703.3,703.4, Medium 3 In Low Replace with an ADA compliant sign.Need to add a sign next to entry door as well.Move the bench 1209 Manford Ave. Building braille,or pictograms.The clear floor space is blocked by a bench. 703.6 to the right to create 18"wide of clear floor space. ....‘III 145 WOMEN Fairgrounds/Event Center- Signs Event Center The Event Center men's and women's restrooms have exterior doors leading to the plaza.703.4 Medium 3 Out High Regrade this area so the slope is less than 2%in any directions. 1125 Rooftop Way Both doors have signs marking the restrooms.The slope of the concrete by the sign is 1.9%to 2.1%which is non-compliant and over the 2%maximum in some parts. 146 J Fairgrounds/Event Center- Signs Event Center The restrooms in the event space of the Event Center do not have a sign. 216.2 High 3 In Low Add an ADA compliant sign to the latch side of each restroom door. ,.... 1125 Rooftop Way 147 Fairgrounds/Pavilion- Controls Pavilion The Pavilion women's restroom light switch is automatic and does not have ADA 309.2 Low 3 In Low Relocate the trashcan to provide the clearest floor space possible,the switch is automatic but can be 1115 Rooftop Way compliant clear floor space at 14"due to the trashcan.With the trashcan removed,there turned off. '. is 28%"wide clear floor space. 148 , Fairgrounds/Pavilion- Controls pavilion The Pavilion women's restroom light switch is automatic and does not have ADA 309.2 Low 3 In Low Relocate the trashcan to provide the clearest floor space possible,the switch is automatic but can be 11 ii 1115 Rooftop Way compliant clear floor space at 14"due to the trashcan.With the trashcan removed,there turned off. is 28%"wide clear floor space. 149 t. Fairgrounds/Event Center- Controls Event Center The doorbell in the Event Center lobby for the office staff is mounted at a non-compliant 309.3,308 High 2 In Low Relocate button so it is mounted at a maximum height of 48"and is not obstructed. 1'- r. 1125 Rooftop Way height.The doorbell is mounted at a height of 53 5/8"-56"which is over the 48" ' CIii 1 m.Additionally,the doorbell control is mounted over a counter that is 433/8" -- - m 150 high and 85/8"deep. Fairgrounds/Event Center- Controls Event Center The ADA door opener button for the Event Center entrance does not have compliant 404.3.5 Medium 2 In or Medium Relocate the button so the clear floor space is located beyond the bottom of the ramp and not behind 1125 Rooftop Way clear floor space.The clear floor space width includes part of the ramp and is 1.97% Out the handrail. cross slope with 2%being the maximum.The button is also located behind the handrail. 151 Fairgrounds/Event Center- Controls Barn W The light switches for Barn W are not compliant.The light switches are located at a 309.3,308 Low 2 Out Medium Lower the light switches so they are at a maximum height of 48".1125 Rooftop Way height of 61 5/8"which is over the 48"maximum.The switches are located 414"behind n� the front of the structural wall beam. 152 �q '' Fairgrounds/Event Center- Controls BarnW The audio volume control knob is not compliant.The knob is located at a height of 52" 309.3,309.4 Medium 4 In or Medium Relocate knob so it is at a maximum height of 48"and replace with an ADA compliant control that "'. 1125 Rooftop Way which is over the 48"maximum.The knob requires tight grasping to operate. Out does not require grasping to operate. I 153 III Fairgrounds/Event Center- Controls Barn W The audio control box has controls located at a non-compliant height of 51%"to 61" 309.3,309.4 Medium 4 In or Medium Lower the audio control box so the controls are no higher than the 48"maximum.Replace non-ADA 1125 Rooftop Way which is over the 48"maximum.Some of the controls are not ADA compliant and require Out compliant controls with ones that do not require tight grasping to operate. T� 154 tight grasping to operate. d Fairgrounds/Grandstands- Controls Grandstands The light switch for the grandstands family restroom south is not complaint The light 309.3 High 3 In or Medium Lower the light switch so the on/off control is mounted at a maximum height of 48". 1209 Manford Ave, switch is automatic,but the on/off button is mounted at a height of 49%"-503/8" Out which is over the 48"maximum. 155 Fairgrounds/Pavilion- Water Fountains Pavilion There are two water fountains located between the Pavilion men's and women's 602.7 High 3 Out High Remove the water fountains and either mount elsewhere in the lobby/building with one ata 1115 Rooftop Way restrooms.They are mounted at similar heights which is not compliant due to needing a wheelchair height and one at a standing height. _ i, I 50/50 split between the wheelchair and standing water fountains.Additionally,they 156 block the clear floor space for the maneuvering clearance for the restroom entrances. Fairgrounds/Event Center- Water Fountains Event Center There are two fountains located in the lobby of the Event Center that are not ADA 602.3,602.6 High 3 In or High Adjust the water fountains so the force requires to operate is less than 5 pounds and the water flow I 1125 Rooftop Way complaint.The water fountains require 7-9 pounds of force to operate which is over the Out greater than the 4"minimum.OR,replace water fountains with ADA compliant ones. 5-pound maximum.The water flow is 2-3"in height which is less than the 4"minimum. 157 Fairgrounds/Pavilion- Restrooms Pavilion The accessible pathway in the Pavilion women's restroom has a cross slope of 2.62%, 403.3 Medium 3 Out High Regrade floor near drains so the floor slope is less than 2%in any direction. 1115 Rooftop Way which is over the 2%maximum,by the floor drains near the ADA and ambulatory stalls. 158 Fairgrounds/Pavilion- Restrooms Pavilion The accessible pathway in the Pavilion men's restroom has a cross slope of 2.62%,which 403.3 Medium 3 Out High Regrade floor near drains so the floor slope is less than 2%in any direction. 1115 Rooftop Way is over the 2%maximum,by the floor drains near the ADA and ambulatory stalls,as well 159 as,the urinals. Fairgrounds/Pavilion- Restrooms Pavilion The ADA and ambulatory stall doors in the Pavilion women's restroom are not ADA 604.8.1.2 Medium 3 In Medium Replace door hinges so the door self-close. , ! t- 1115 Rooftop Way compliant with the doors not being self-closing and instead self-open 1/8-%of the way. 160 f Fairgrounds/Pavilion- Restrooms Pavilion The toilet paper dispenser in the Pavilion women's restroom 1st ADA stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. /_ 1115 Rooftop Way compliant.The dispenser is mounted 6"and 14"from the front of the toilet which is outside of the 7-9"range. 161 c Fairgrounds/Pavilion- Restrooms Pavilion The trashcan in the Pavilion women's restroom 1st ADA stall is not compliant.The 604.7 High 3 In High Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the 1115 Rooftop Way trashcan is 33"from the side of the toilet and is 22"behind the front of the toilet.The toilet. outlet height of the trashcan is 8"which is less than the 15"minimum. -10 162 Fairgrounds/Pavilion- Restrooms Pavilion The toilet in the 2nd ADA stall in the Pavilion women's restroom is not compliant.The 604.2 Medium 3 Out High Adjust the stall wall so the toilet centerline is 16-18"from the stall wall. --'--,..... 1115 Rooftop Way toilet is 18'h"from the side wall which is over the 18"maximum. 163 0 Fairgrounds/Pavilion- Restrooms Pavilion The toilet paper dispenser in the pavilion women's restroom 2nd ADA stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1115 Rooftop Way compliant.The dispenser is mounted 6"and 14"from the front of the toilet which is outside of the 7-9"range. 164 Fairgrounds/Pavilion- Restrooms Pavilion The trashcan in the Pavilion women's restroom 2nd ADA stall is not compliant.The 604.7 High 3 In Medium Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the 1115 Rooftop Way trashcan is 8"from the side of the toilet and is 20"behind the front of the toilet The toilet outlet height of the trashcan is 8"which is less than the 15"minimum. 165 Fairgrounds/Pavilion- Restrooms Pavilion The toilet in the ambulatory stall in the Pavilion women's restroom is not compliant.The 604.4 High 3 In Medium Replace toilet with an ADA compliant one with a seat height 17-19". 1115 Rooftop Way toilet seat height is 15%"which is less than the 17"minimum. 166 Fairgrounds/Pavilion- Restrooms Pavilion The toilet paper dispenser in the pavilion women's restroom Ambulatory stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1115 Rooftop Way compliant.The dispenser is mounted 6"and 14"from the front of the toilet which is outside of the 7-9"range. 167 1 Fairgrounds/Pavilion- Restrooms Pavilion The trashcan in the Pavilion women's restroom Ambulatory stall is not compliant.The 604.7 High 3 In High Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the 1115 Rooftop Way trashcan is 7"from the side of the toilet and is 19"behind the front of the toilet.The toilet. outlet height of the trashcan is 8"which is less than the 15"minimum. 168 Fairgrounds/Pavilion- Restrooms Pavilion The toilet in the ADA stall of the pavilion men's restroom is not compliant.The toilet seat 604.4 High 3 In Medium Replace toilet with an ADA compliant one with a seat height 17-19". 1115 Rooftop Way height is 15%"which is less than the 17"minimum. 169 Fairgrounds/Pavilion- Restrooms Pavilion The toilet paper dispenser in the pavilion men's restroom Ambulatory stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1115 Rooftop Way compliant.The dispenser is mounted 6"and 13"from the front of the toilet which is outside of the 7-9"range. 170 Fairgrounds/Pavilion- Restrooms Pavilion The trashcan in the Pavilion men's restroom Ambulatory stall is not compliant.The 604.7 High 3 In High Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the —....." 1115 Rooftop Way trashcan is 9"from the side of the toilet and is 20"behind the front of the toilet.The toilet. outlet height of the trashcan is 8"which is less than the 15"minimum. 171 0 Fairgrounds/Pavilion- Restrooms Pavilion The ambulatory stall in the Pavilion men's restroom is not compliant.The door self- 604.81.2 Medium 3 In Medium Replace door hinges so the door self-closes. 1115 Rooftop Way opens instead of self-closing. 172 Fairgrounds/Pavilion- Restrooms Pavilion The toilet in the ambulatory stall of the Pavilion women's restroom is not compliant.The 604.4 High 3 In Medium Replace toilet with one that has a seat height of 17-19". 1115 Rooftop Way toilet seat is 15 15"from the floor which is less than the 17"minimum. 173 1 0 Fairgrounds/Pavilion- Restrooms Pavilion The toilet paper dispenser in the pavilion men's restroom Ambulatory stall is not 604.4 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1115 Rooftop Way compliant.The dispenser is mounted 4"and 12"from the front of the toilet which is outside of the 7-9"range. 174 Oli Fairgrounds/Grandstands- Restrooms Grandstands The accessible pathway in the Grandstands women's restroom has a cross slope of 2.44%,403.3 Medium 3 Out High Regrade floor near drains so the floor slope is less than 2%in any direction. 1209 Manford Ave. which is over the 2%maximum,by the floor drains near the ADA and ambulatory stalls. — 175 Fairgrounds/Grandstands- Restrooms Grandstands The counter and sinks in the Grandstands women's restroom are not compliant with a 606.3 High 3 In or High Remount a minimum of one of the sinks so the counter top height is no higher than 34" 1209 Manford Ave. height of 34)6"—34 5/8"which is over the 34"maximum. Out 176 Fairgrounds/Grandstands- Restrooms Grandstands The mirrors in the Grandstands women's restroom are not compliant with a height of 40 603.3 Medium 3 In or Medium Remount a minimum of one of the mirrors so the bottom reflective surface height is no higher than 1209 Manford Ave. Yr"-41%"which is over the 40"maximum. Out 40". 177 0 Fairgrounds/Grandstands- Restrooms Grandstands The ambulatory stall in the Grandstands women's restroom is not compliant.The width 604.8 2.1,404.2.3, High 3 In and High The stall needs to be redone so the width is 35"-37".The door should be located no more than 4" ' 1209 Manford Ave. of the stall is 40"which is over the 37"maximum.The door is 5 7/8"from the side wall 404.2 7,604.8.1.2 Out from the latch side.The entry door needs to be a minimum of 32"wide.Add an ADA compliant door which is over the 4"maximum.The entry door is 30 3/8"which is less than the 32" handle to the inside of the door Replace door hinges so the door self-closes. 178 minimum.There is a door handle on the outside of the door only.The door is not self- closing. Fairgrounds/Grandstands- Restrooms Grandstands The toilet in the Grandstands women's restroom ambulatory stall is not compliant.The 604.2,604.4 High 3 In and Low and The toilet distance from the walls should be solved with the resrting of the stall to the appropriate 1209 Manford Ave. toilet is 22%"and 1711"from the side walls while the required range is 17-19".The toilet Out High width.Replace the toilet with an ADA one that has a seat height of 17-19". 179 has a seat height of 15%"which is less than the 17"minimum. { , Fairgrounds/Grandstands- Restrooms Grandstands The trashcan in the Grandstands women's restroom Ambulatory stall is not compliant. 604.7 High 3 In High Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the 1209 Manford Ave. The trashcan is 12"from the side of the toilet and is 20"behind the front of the toilet. toilet The outlet height of the trashcan is 8"which is less than the 15"minimum. 180 Fairgrounds/Grandstands- Restrooms Grandstands The ADA stall in the Grandstands women's restroom is not compliant.The door self- 604.8.1.2 Medium 3 In Medium Replace door hinges so the door self-closes.Add an ADA compliant door handle to the inside of the 1209 Manford Ave. opens instead of self-closing.There is a door handle on the outside of the door only. door. 11.41 181 . I 1 Fairgrounds/Grandstands- Restrooms Grandstands The toilet in the Grandstands women's restroom ADA stall is not compliant.The toilet is 604.2,604.4,604.6 High 3 In and Low and The toilet centerline needs to be 16-18"from the side wall Add material to wall to extend wall 1" 1209 Manford Ave. 19"from the side walls while the required range is 16-18"The toilet has a seat height of Out High minimum towards toilet.Replace the toilet with an ADA one that has a seat height of 17-19"and has 15%"which is less than the 17"minimum.The flush controls are on the closed side of the flush controls on the right(open)side of the toilet. 182 toilet. Fairgrounds/Grandstands- Restrooms Grandstands The toilet paper dispenser in the Grandstands women's restroom ADA stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1209 Manford Ave. compliant.The dispenser is mounted 615"and 13"from the front of the toilet which is outside of the 7-9"range. 183 Fairgrounds/Grandstands- Restrooms Grandstands The trashcan in the Grandstands women's restroom ADA stall is not compliant The 604.7 High 3 In High Mount a trashcan on the wall so the outlet height is 15-48"in height and is 7-9"from the front of the 1209 Manford Ave. trashcan is 31"from the side of the toilet and is 20"behind the front of the toilet.The toilet outlet height of the trashcan is 8"which is less than the 15"minimum. 184 Fairgrounds/Grandstands- Restrooms Grandstands The ambulatory stall in the Grandstands men's restroom is not compliant.The width of 604.8.2.1,404.2.3, Medium 3 In and High The stall needs to be redone so the width is35"-37".The entry door needs to be a minimum of 32" 1209 Manford Ave. the stall is 37 1/2"which is over the 37"maximum.The entry door is 30"which is less 404.2.7,604.8.1.2 Out wide.Add an ADA compliant door handle to the inside of the door.Replace door hinges so the door than the 32"minimum.There is a door handle on the outside of the door only.The door self-closes. 185 is not self-closing. Fairgrounds/Grandstands- Restrooms Grandstands The toilet paper dispenser in the Grandstands men's restroom Ambulatory stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1209 Manford Ave. compliant.The dispenser is mounted 6"and 14"from the front of the toilet which is outside of the 7-9"range. 186 Fairgrounds/Grandstands- Restrooms Grandstands The toilet in the Grandstands men's restroom ambulatory stall is not compliant.The toilet 604.2,604.4 High 3 In and Low and The toilet distance from the walls should be solved with the resizing of the stall to the appropriate 1209 Manford Ave. is 20 36"and 17"from the side walls while the required range is 17-19".The toilet has a Out High width.Replace the toilet with an ADA one that has a seat height of 17-19". seat height of 1514"which is less than the 17"minimum. 187 Fairgrounds/Grandstands- Restrooms Grandstands The toilet paper dispenser in the Grandstands men's restroom Ambulatory stall is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1209 Manford Ave. compliant.The dispenser is mounted 4"and 12"from the front of the toilet which is outside of the 7-9"range. 188 Fairgrounds/Grandstands- Restrooms Grandstands The ADA stall in the Grandstands men's restroom is not compliant The door self-opens 604.81.2 Medium 3 In Medium Replace door hinges so the door self-closes.Add an ADA compliant door handle to the inside of the 1209 Manford Ave. instead of self-closing There is a door handle on the outside of the door only. door. 189 k Fairgrounds/Grandstands- Restrooms Grandstands The toilet in the Grandstands men's restroom ADA stall is not compliant.The toilet is 18 604.2 High 3 In and Low and The toilet centerline needs to be 16-18"from the side wall.Add material to wall to extend wall Y." 1209 Manford Ave. 34"from the side walls while the required range is 16-18". Out High minimum towards toilet. 190 Fairgrounds/Grandstands- Restrooms Grandstands The coat hook in the grandstands family restroom south has a non-compliant coat hook. 603.4 Medium 3 In Low Remount coat hook so it is at a height of no more than 48". I 1209 Manford Ave. The coat hook is mounted at a height of 60 Y."which is over the 48"maximum. 191 Fairgrounds/Grandstands- Restrooms Grandstands The rear ADA grab bar in the grandstands family restroom north is not compliant with 11 609.4 Medium 3 N/A N/A This will no longer be an ADA compliant restroom or remount rear ADA grab bar. 1209 Manford Ave. 'h"to the closed side and 24 11"to the open side. 192 4.--- Fairgrounds/Grandstands- Restrooms Grandstands The toilet in the Grandstands family restroom south is not compliant.The toilet is 185/8"604.3,604.6 High 3 In and Low and The toilet centerline needs to be 16-18"from the side wall Add material to wall to extend wall 5/8" 1209 Manford Ave. from the side walls while the required range is 16-18".The flush controls are on the Out High minimum towards toilet.Replace toilet with an ADA one that has flush control on the right(open) closed side. side of the toilet 193 Fairgrounds/Grandstands- Restrooms Grandstands The toilet paper dispenser in the grandstands family restroom south dispenser is mounted 604.7 Medium 3 In Low Remount so one of the outlets is within the 7-9"distance from the front of the toilet. 1209 Manford Ave. so the outlets are 4"and 12"from the front of the toilet which are not in the 7-9" distance. 194 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The counter and sinks in the Stanley Park men's restroom is not compliant.The counter 606.3 High 3 In or Medium Remount the counter so the top is no more than 34"and there is compliant knee and toe space. 1209 Manford Ave. Building has a top height of 34 IV which is over the 34"maximum. Out 195 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The mirror over the counter in the Stanley Park men's restroom is not compliant.The 603.3 High 3 In Medium Remount mirror so the bottom reflective surface is no more than 40"in height. 1209 Manford Ave. Building mirror is mounted with the bottom reflective surface at 451/8"which is over the 40" 196 maximum. Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The counter and sinks in the Stanley Park women's restroom is not compliant.The 606.3 High 3 In or Medium Remount the counter so the top is no more than 34"and there is compliant knee and toe space. 1209 Manford Ave. Building counter has a top height of 34'h"which is over the 34"maximum. Out 197 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom There are 3 urinals and 3 toilets for a total of six in the Stanley Park men's restroom,one 213.3.1 Medium 3 In or Medium Add an ambulatory stall that is 35-37"wide which the other stalls are close to being. -' 1209 Manford Ave. Building is ADA and none are ambulatory. Out 198 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The grab bars in the Stanley Park men's restroom are not compliant.The rear grab bar is 609.4 Medium 3 In Low Remount the grab bars so the maximum height is 36"The rear should be offset with 24"to the open 1209 Manford Ave. Building centered on the toilet instead of offset with 24"to the open side The bar is mounted at side and the side should be no more than 12"from the rear wall. a height of 36Y.".The side grab bar is mounted 13"from the rear wall which is over the 199 12"maximum The bar is mounted at a height of 3614"which is over the 36"maximum. Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The ADA stall in the Stanley Park men's restroom is not compliant.The stall width is 41" 604.8.1.1,604.8.1.2 High 3 In and High Resize partitions so the stall is 60"wide minimum and door is no more than 4"from the side wall. 1209 Manford Ave. Building and narrows to 3934"by the toilet.The door is 415"from the side wall which is over the Out Replace hinges so door is self-closing.Add door pull to inside of door. 4"maximum.The stall door is not self-closing and has a pull handle on the outside only. 200 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The toilet in the Stanley Park men's restroom ADA stall is not compliant.The toilet is 604.2,604.6 High 3 Out High Remount an ADA compliant toilet with the flush control to the open side. !, 1209 Manford Ave. Building located 20"from the side wall which is over the 18"maximum.The flush control is mounted in the middle of the top of the tank instead of the open side 201 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The urinals in the Stanley Park men's restroom are not compliant.The stall widths are 29 605.2,305.3 High 3 In or Medium Resize the stall width so the right one is a minimum of 30"wide.Replace the urinal with one that is Y. '1 , 1209 Manford Ave. Building "to which is less than the 30"minimum.The depth of the outer face from the Out ADA compliantwiththe depth of the outer face a minimum of 13%". support is 13"which is less than the 1311"minimum. 202 rear J _ ,+ Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The mirror over the counter in the Stanley Park women's restroom is not compliant The 603.3 High 3 In Medium Remount mirror so the bottom reflective surface is no more than 40"in height. 1209 Manford Ave. Building mirror is mounted with the bottom reflective surface at 461"which is over the 40" maximum. -f 203 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom There is a shelf on the south side of the Stanley Park women's restroom that is not 603.4 High 3 In Medium Remount shelf so top height is no more than 34". 1209 Manford Ave. Building compliant.The shelf is 11"deep and is mounted at a height of 391/8"which is over the 34"maximum for a depth of shelf over 10". 204 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The mirror over the shelf in the Stanley Park women's restroom is not compliant.The 603.3 High 3 In Medium Remount mirror so the bottom reflective surface is no more than 40"in height. I. 1209 Manford Ave. Building mirror is mounted with the bottom reflective surface at 46 Y."which is over the 40" maximum. i 205 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom There are 7 toilets for a total of six stall in the Stanley Park women's restroom,one is 213.31 High 3 In or Medium Add an ambulatory stall that is 35-37"wide which the other stalls are close to being. 1209 Manford Ave. Building ADA and none are ambulatory. Out 206 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The grab bars in the Stanley Park women's restroom are not compliant.The rear grab 604.5 Medium 3 In Low Remount the grab bars so the maximum height is 36".The rear should be offset with 24"to the open 1209 Manford Ave. Building bar is centered on the toilet instead of offset with 24"to the open side.The bar is side and the side should be no more than 12"from the rear wall. mounted at a height of 36 Y".The side grab bar is mounted 111/2"from the rear wall 207 and extend 53 M"from the rear wall which is less than the 54"minimum.The bar is mounted at a height of 37 3/8"which is over the 36"maximum. Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The ADA stall in the Stanley Park women's restroom is not compliant.The stall width is 604.3 High 3 In and High Resize partitions so the stall is 60"wide minimum and door is no more than 4"from the side wall. 1209 Manford Ave. Building-Women's 41"and narrows to 393/4"by the toilet.The door is4Y"from the side wall which is over Out Replace hinges so door is self-closing.Add door pull to inside of door. the 4"maximum The stall door is not self-closing and has a pull handle on the outside 208 only. Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The toilet in the ADA stall is not compliant.The toilet is located 20 M"and 19%"from the 604.2,604.6 High 3 In High Remount an ADA compliant toilet with the flush control to the open side. 1209 Manford Ave. Building-Men's side walls which is over the 18"maximum.The flush control is mounted in the middle of the top of the tank instead of the open side. 209 Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The women's side of the Stanley Park restrooms does not have an ADA compliant shower 608.2,608.3,608.6 High 3 In High Install the current grab bar on the back of the shower compartment.Install a 42"grab bar on the side 'M ir x 1209 Manford Ave. Building-Women's stall The left shower stall is the closest to being ADA compliant.The shower has a depth of the shower compartment.Replace the shower head with a handheld type that has a hose length o' of 48"to the curtain and 60"to the end of the stall.There is no rear grab bar present. 59"minimum.Move the curtain rod to the end of the shower compartment so the depth is 60" 210 The side grab bar is only 36"and not the minimum 42".The grab bar is mounted with a minimum. height of 36 Y."which is over the 36"maximum.The shower head is over 48"and there is no handheld shower spray unit Fairgrounds/Grandstands- Restrooms Stanley Park Restroom The men's side of the Stanley Park restrooms does not have an ADA compliant shower 608.2,608.3,608.6 High 3 In High Install the current grab bar on the back of the shower compartment.Install a 42"grab bar on the side 11. 1209 Manford Ave. Building-Men's stall.The left shower stall is the closest to being ADA compliant.The shower has a depth of the shower compartment.Replace the shower head with a handheld type that has a hose length o' of48"to the curtain and 60"to the end of the stall.There is no rear grab bar present. 59"minimum.Move the curtain rod to the end of the shower compartment so the depth is 60" IF 14 211 The side grab bar is only 36"and not the minimum 42".The grab bar is mounted with a minimum. height of 36%"which is over the 36"maximum.The shower head is over 48"and there is no handheld shower spray unit. Fairgrounds/Event Center- Restrooms Event Center-Women's The counter and sinks in the Event Center women's restroom are not compliant.The 606.2 High 3 In or High Raise the counter so the bottom of the sink basins are a minimum of 27"from the floor. it, 1125 Rooftop Way Public bottom of the sink basins are 26t"from the floor which is less than the 27"minimum. Out 7 g*allem. 1-` - 212 'T iiiiiiio: Fairgrounds/Event Center- Restrooms Event Center-Women's The mirror in the Event Center women's restroom is not compliant with a height for the 603.3 High 3 In or High Remove the upper counter and remount the mirror so the bottom reflective surface is no higher than- - -• 1125 Rooftop Way Public bottom reflective surface of 41 Y."which is over the maximum of 40". Out the 40"maximum. 213 Fairgrounds/Event Center- Restrooms Event Center-Women's The tampon dispenser in the Event Center women's restroom is not compliant.The coin 604.7 High 3 In Low Remount the dispenser so the height of the coin slot is no more than 48"The other controls are 1125 Rooftop Way Public slot for the dispenser is mounted at a height of 48 Y."which is over the 48"maximum. below the coin slot. '_. 214 • Fairgrounds/Event Center- Restrooms Event Center-Women's The ADA stall in the Event Center women's restroom is not compliant.The door is not 604.8.1.2 Medium 3 In Medium Replace door hinges so the door self-closes.Add an ADA compliant door handle to the inside of the 1125 Rooftop Way Public self-closing and has a handle on the outside of the door only. door. 215 Fairgrounds/Event Center- Restrooms Event Center-Women's The toilet in the Event Center women's restroom ADA stall is not compliant.The toilet 604.6 Medium 3 In Low Adjust toilet flush controls so it requires no more than 5 pounds to operate. - 1125 Rooftop Way Public requires 6 pounds of force to flush which is over the 5 pounds maximum. 216 Fairgrounds/Event Center- Restrooms Event Center-Women's The grab bars in the Event Center women's restroom ADA stall are not compliant.The 604.5 Low 3 In Low Remount grab bar so there is 12"to the closed side and 24"to the open side of the toilet. 1125 Rooftop Way Public rear grab bar is ft"too far to the open side of the toilet. 217 Fairgrounds/Event Center- Restrooms Event Center-Women's The Event Center women's restroom ADA stall does not have a toilet seat cover dispenser 604.7 Low 3 In Low Mount a toilet cover dispenser near the toilet with a reach height from 15"-48"and has adequate 1125 Rooftop Way Public like the other stalls do including the ambulatory stall. space from the grab bars.Add dispenser at a compliant height to the ADA stall. 218 "• O Fairgrounds/Event Center- Restrooms Event Center-Women's The Ambulatory stall in the Event Center women's restroom is not compliant.The door is 604.8.1.2 Medium 3 In Medium Replace door hinges so the door self-closes.Add an ADA compliant door handle to the inside of the 1125 Rooftop Way Public not self-closing and has a handle on the outside of the door only. door. 219 Fairgrounds/Event Center- Restrooms Event Center-Women's The toilet in the Event Center women's restroom ambulatory stall is not compliant.The 604.4 High 3 In Medium Replace the toilet with an ADA one that has a seat height of 17-19". q 1125 Rooftop Way Public toilet has a seat height of 14 b"which is less than the 17"minimum. 220 j C' r •• Fairgrounds/Event Center- Restrooms Event Center-Family The counter and sinks in the Event Center family restroom are not compliant.The 606.2 High 3 In or Medium Raise the counter so the bottom of the sink basins are a minimum of 27"from the floor. 1125 Rooftop Way bottom of the sink basins are 26'k"from the floor which is less than the 27"minimum. Out 221 Fairgrounds/Event Center- Restrooms Event Center-Family The toilet in the Event Center family restroom is not compliant.The toilet is 20"from the 604.2 Medium 3 In Medium Add material to the wall to extend it 2"minimum towards the toilet. 1125 Rooftop Way side wall while the required range is 16-18". I 222 7i' Fairgrounds/Event Center- Restrooms Event Center-Family The grab bars in the Event Center Family restroom are not compliant The rear grab bar 604.5 Medium 3 In Low Remount grab bar so there is 12"to the closed side and 24"to the open side of the toilet. 1125 Rooftop Way is 234"too far to the closed side of the toilet. �, 223 Fairgrounds/Event Center- Restrooms Event Center-Family The toilet paper dispenser in the Event Center family restroom is not compliant.The 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1125 Rooftop Way dispenser is mounted 1 X"and 12"from the front of the toilet which is outside of the 7- 9"range. 224 Fairgrounds/Event Center- Restrooms Event Center-Men's The counter and sinks in the Event Center men's restroom are not compliant.The 606.3 High 3 In or High Raise the counter so the bottom of the sink basins are a minimum of 27"from the floor. 1125 Rooftop Way Public bottom of the sink basins are 25%"from the floor which is less than the 27"minimum. Out 225 Fairgrounds/Event Center- Restrooms Event Center-Men's The ADA stall in the Event Center men's restroom is not compliant.The door is not self- 604.8.1.2 Medium 3 In Medium Adjust the partition wall and door soi the door is no more than 4"from the side wall.Replace door 1125 Rooftop Way Public closing and has a handle on the outside of the door only.The stall door is 4Y."from the hinges so the door self-closes.Add an ADA compliant door handle to the inside of the door. side wall which is over the 4"maximum. 226 Fairgrounds/Event Center- Restrooms Event Center-Men's The toilet in the Event Center men's restroom ADA stall is not compliant.The toilet isl8 604.2,604.6 Medium 3 In High Adjust the flush control so that it requires no more than 5 pounds of force to operate Add material 1125 Rooftop Way Public '4"from the side walls while the required range is 16-18".The toilet requires 6 pounds of to the wall to extend it%.."minimum towards the toilet. force to operate which is over the 5-pound maximum 227 Fairgrounds/Event Center- Restrooms Event Center-Men's The Event Center men's restroom ADA stall does not have a toilet seat cover dispenser 604.7 Low 3 In Low Mount a toilet cover dispenser near the toilet with a reach height from 15"-48"and has adequate • 1125 Rooftop Way Public like the other stalls do including the ambulatory stall. space from the grab bars.Add a dispenser at a compliant height to the ADA stall. --- 226 0 Fairgrounds/Event Center- Restrooms Event Center-Men's The Ambulatory stall in the Event Center men's restroom is not compliant.The door is 604.81.2 Medium 3 In Medium Replace door hinges so the door self-closes.Add an ADA compliant door handle to the inside of the — 1125 Rooftop Way Public not self-closing and has a handle on the outside of the door only. door. 0 229 Fairgrounds/Event Center- Restrooms Event Center-Men's The toilet in the Event Center men's restroom ambulatory stall is not compliant.The 604.4,604.6 High 3 In High Replace the toilet with an ADA one that has a seat height of 17-19"and has a flush control that 1125 Rooftop Way Public toilet has a seat height of 14'h"which is less than the 17"minimum.The toilet requires 6 requires no more than 5 pounds of force to operate. pounds of force to operate which is over the 5-pound maximum. _ 230 Fairgrounds/Event Center- Restrooms Event Center-Men's The toilet paper dispenser in the Event Center men's restroom ADA stall is not compliant.604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1125 Rooftop Way Public The dispenser is mounted 1"and 8"from the front of the toilet which is outside of the 7- 9"range. 231 Fairgrounds/Event Center- Restrooms Event Center-event The counter and sinks in the Event Center event space east restroom are not compliant. 606.3 High 3 In or Medium Raise the counter so the bottom of the sink basins are a minimum of 27"from the floor. 1125 Rooftop Way space The bottom of the sink basins are 26 3/8"from the floor which is less than the 27" Out 232 minimum. I I i Fairgrounds/Event Center- Restrooms Event Center-event The toilet in the Event Center event space east restroom is not compliant.The toilet is 18 604.2 Medium 3 In Medium Add material to the wall to extend it'A"minimum towards the toilet. 1 1125 Rooftop Way space '4"from the side wall while the required range is 16-18". 233 Fairgrounds/Event Center- Restrooms Event Center-event The toilet paper dispenser in the Event Center event space east restroom is not 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. 1125 Rooftop Way space compliant.The dispenser is mounted 6"and 12"from the front of the toilet which is outside of the 7-9"range. 234 Fairgrounds/Event Center- Restrooms Event Center-event The grab bars in the Event Center event space east restroom ADA stall are not compliant.604.5 Medium 3 In Medium Remount grab bar so there is 12"to the closed side and 24"to the open side of the toilet.Remount ...i i 1125 Rooftop Way space The rear grab bar is'4"too far to the closed side of the toilet.The toilet cover dispenser is toilet cover dispenser below the grab bar with a minimum of 154"between them. mounted 4%"above the rear grab bar which is lower than the 12"minimum for object -. 235 above a grab bar. Fairgrounds/Event Center- Restrooms Event Center-event The counter and sinks in the Event Center event space west restroom are not compliant. 606.3 High 3 In or Medium Raise the counter so the bottom of the sink basins are a minimum of 27"from the floor. 1125 Rooftop Way space The bottom of the sink basins are 26 Y."from the floor which is less than the 27" Out 236 minimum. t Fairgrounds/Event Center- Restrooms Event Center-event The toilet in the Event Center event space west restroom is not compliant.The toilet is 19604.4 High 3 In Medium Adjust the flush control so that it requires no more than 5 pounds of force to operate Add material • 1125 Rooftop Way space ''A"from the side wall while the required range is 16-18".The flush control requires 7 to the wall to extend it 136"minimum towards the toilet. pounds of force to operate which is over the 5-pound maximum. 237 Fairgrounds/Event Way Center- Restrooms Event Center-event The toilet ompliant.paperThedispenser dispenserinismounted 2"the Event Centerand12"eventspacefromthef westrestroomrontofthetoilet is notwhich is 604.7 High 3 In Medium Remount toilet paper dispenser so there is a roll that is in the 7-9"range from the front of the toilet. op space outside of the 7-9"range. 238 Fairgrounds/Event Center- Restrooms Event Center-event The grab bars in the Event Center event space west restroom ADA stall are not compliant.604.5 Medium 3 In Medium Remount grab bar so there is 12"to the closed side and 24"to the open side of the toilet.Remount 1125 Rooftop Way space The rear grab bar is l%"too far to the closed side of the toilet.The toilet cover dispenser toilet cover dispenser below the grab bar with a minimum ofl%"between them. is mounted 5 3/8"above the rear grab bar which is lower than the 12"minimum for 239 object above a grab bar. Riverside Restroom Building-110 Parking Lot East Riverside Parking Lot There are 43 parking spaces with 3 ADA spaces.None of the ADA spaces are sized or 208.2,502.2 High 1 In Medium Restripe the ADA parking space pair so that the left ADA space is van accessible and the right space is E.Riverside Dr. marked for"Van Accessible".Based on the total space number,two ADA spaces are a normal ADA space.Due to the angled parking space configuration,the van accessible space must required with one being van accessible. have the access aisle on the passenger side. 240 Riverside Restroom Building-110 Parking Lot East Riverside Parking Lot The left ADA space has across slope in the middle measured at 2.1%which is over the 2%502.4 Low 1 Out High Regrade parking space so the slope is less than 2%in any direction. r E.Riverside Dr. maximum. 241 Riverside Restroom Building-110 Parking Lot East Riverside Parking Lot The right ADA space has a cross slope in the middle measured at 2.27%which is over the 502.4 Low 1 Out High Regrade parking space so the slope is less than 2%in any direction. E.Riverside Dr. 2%maximum 1 242 Riverside Restroom Building-110 Parking Lot East Riverside Parking Lot The access aisle for the SE corner ADA parking space is not connected to the accessible 502.3 High 1 In Medium Remove ADA parking space since only 2 are needed.Or grind down vertical change so there isa 4 _ E.Riverside Dr. route.There is a 1"vertical change due to no curb cut and makes the aisle and parking m of%"vertical change.Access aisle is still non-compliant and parking spaces would need to — S,-'- 243 pace not connected to the accessible route.The aisle is also in a triangle shape with the be reconfigured to make it compliant. —- _ _ _ rear 76"in width and 166"in length. a -� Y Riverside Restroom Building-110 Parking Lot East Riverside Parking Lot The ADA space in the SE corner(near Casa Grande)does not have a sign for the parking 502.6 High 1 In Low Add a sign,if space is staying.E.Riverside Dr. space. _--- 244 s Riverside Restroom Building-110 Accessible Route Flagstone Sidewalks There are several spots where the gap between flagstone is 54"-2"wide and up to 1%" 302.3 High 1 In or High Fill gaps between flagstone with crushed gravel(compacted)or concrete. r E.Riverside Dr. deep. Out 245 • Riverside Restroom Building-110 Accessible Route Flagstone Sidewalks Flagstone walkways to and around restroom building have flagstone unlevel with vertical 303.2 High 1 Out High Level flagstone so there is no vertical change over%" Fill low areas or areas missing flagstone pieces - L- - - '' -- E.Riverside Dr. changes measured at'''4" 1%". with crushed gravel(compacted)or concrete. I 246 '? i _ - Riverside Restroom Building-110 Accessible Route Flagstone Sidewalks The flagstone around the steps to the raised area(womens memorial)have vertical 303.2 High 1 Out High Level flagstone so there is no vertical change over SO".Fill low areas or areas missing flagstone pieces I i 1 ' E.Riverside Dr. changes of%"-2%". with crushed gravel(compacted)or concrete. _ ._ " ' • ,. - Q wV'' 247 - �, ` Riverside Restroom Building-110 Accessible Route North Side Restroom The accessible route outside the entry to the women's restroom side of the building has a 403.3 Medium 1 Out High Regrade area so the slope is less than 2%in any direction. E.Riverside Dr. Building cross slope of 2.27%which is over the 2%maximum. 248 Ill Riverside Restroom Building-110 Curb Ramps East Riverside Parking Lot The curb cut for the ADA parking space pair is not compliant.The counter slope is 9.28% 405.2,406.2,406.3 High 1 Out High Redo curb ramp so that it is compliant with the 2010 ADA standards. ----. ' .- E.Riverside Dr. By Playground which is over the 5%maximum.The running slope of the ramp was measured at 8.75%- 9.45%which is over the 8.33%maximum.The right curb flare has a slope of 9.8%is close 249 to the 10%maximum fora curb ramp without a top landing. Riverside Restroom Building-110 Ramps West side of restroom The ramp to the women's side of the restroom building is non-compliant.The running 405.2,405.7 High 1 Out High Regrade ramp so the running slope is between 8.33%and 10%.Regrade ramp landings so the slope is r :,it; E.Riverside Dr. building slope of the ramp is 11.22%which is over the 10%maximum for a ramp with 6-z"height less than 2%in any direction. J.'4 rise.The bottom ramp landing has a slope of 3.84%and the top has a cross slope of I 250 2.44%. r • Riverside Restroom Building-110 Ramps-Handrail West side of restroom The ramp to the women's side of the restroom building has a handrail on one side. 405.8 Medium 1 Out Medium Redo existing handrail so that it is compliant.Add a second ADA compliant handrail to the other side. t .75170 E.Riverside Dr. building Handrails should be on both sides.The height of the handrail is 33 31"which is less than the 34"minimum.The handrail does not extend past the bottom of the ramp. 251 Riverside Restroom Building-110 Ramps North side of restroom The ramp by the entry to the men's side oftherestroom building is not compliant.The 405.2,405.3,405.7 High 1 Out High Regrade ramp so the running slope is between 8.33%and 10%The landings should have a slope of '> E.Riverside Dr. building running slope of the ramp is 10.16%which is over the 10%maximum.The cross slope of less than 2%in any direction.Add an ADA compliant handrail to both sides of ramp. the ramp is 2.1%which is over the 2%maximum.The top landing has a slope of 2 44% 252 which is over the 2%maximum There are no handrail present. Riverside Restroom Building-110 Stairs East side of Women's The stairs to the raised area(new monument)are not compliant.There are no 505.2,403.3,303.2 High 1 In or High Add handrails to both sides of stairs.Redo landings so the slope in any direction is less than 2% - _ E.Riverside Dr. monument handrails on either side.The landings at the top and bottom have non-compliant vertical Out maximum. --_-t-_ ^. - ,-- changes,or have slope over 5%.253 . Riverside Restroom Building-110 Entrances Women's side of The entrance to the women's side of the restroom building is not compliant.The 404,24,404.2.5, High 1 In and High Regrade maneuvering space and accessible route directly outside the women's entrance while raising E.Riverside Dr. restroom maneuvering space on the exterior of the building has a slope of 2 44%which is over the 404.27 Out the slab to make the threshold no more than%"in height with the top 14"beveled 1:2.The slab 2%maximum The threshold has a total height of 3"made up of several sections of should have a slope of less than 2%in any direction for the maneuvering space of the entrance. 254 material with the top)4"beveled.The interior door handle is mounted with the bottom Move the interior door handle down in height so the entire handle is 34"-48" of the handle 1"below the maximum height and the remainder of the handle above the maximum height. Riverside Restroom Building-110 Entrances Men's side ofrestroom The entrance to the men's side of the restroom building is not compliant.The slope 404.24,404.2.7, Medium 1 In and High Regrade the surface outside the men's entry so the slope is less than 2%in any direction.Move the --T'' E.Riverside Dr. outside of the entry is 2.1%which is over the 2%maximum.The handles on both side of 404.28 Out handles down in height so the entire handle is 34"-48"Adjust door closer so the door closes from I-- 4 . the entry doors are mounted at a height where the majority of the handle is not 90°to 12°in 5 second minimum. 255 ompliant.The door closes from 90°to 12°in 3.5 seconds which is less than the 5 second • minimum. • Riverside Restroom Building-110 Signs Women's side of The women's entry sign on the door to the women's side of the restroom building is not 703.4,703.6,703.7 Low 2 In and High The clear floor space will be fixed with corrective measure B15.The sign should be replaced with an E.Riverside Dr. restroom compliant.The clear floor space has a slope of 2.1%which is over the 2%maximum.The Out ADA compliant one that represents the current state of the restroom. Y. pictogram on the sign is too small measuring at 5 "height for the field which is less than 256 the 6"minimum.Additionally,the sign has the international symbol for disability,but is • not wheelchair compliant nor ADA friendly. Riverside Restroom Building-110 Signs Women's side of The 24-hour restroom sign by the women's entry is mounted at a non-compliant height. 703.2,703.3 Low 2 In Low Replace sign with one that has raised text and braille and mount at compliant height with lowest �;,x,' E.Riverside Dr. restroom There is no braille or raised text present. baseline at 48"minimum and highest baseline at 60"maximum. 257 . Riverside Restroom Building-110 Signs Men's side of restroom The men's entry side on the door to the men's side of the restroom building is not 703.6 Low 2 In Low Replace sign with an ADA complaint one. a - Y E.Riverside Dr. compliant.The pictogram has a measurement of 5 Y."which is less than 6". -- 258 Riverside Restroom Building-110 Signs Men's side ofrestroom The 24-hour restroom sign by the men's entry is mounted at a non-compliant height. 703.2,703.3 Low 2 In and High Replace sign with one that has raised text and braille and mount at compliant height with lowest E.Riverside Dr. There is no braille or raised text present. Out baseline at 48"minimum and highest baseline at 60"maximum. 259 Riverside Restroom Building-110 Restrooms Women's The counter is not level.The right sink knee height is 2714"while the middle and left are 606.2 N/A 3 N/A N/A None E.Riverside Dr. 26%".The right sink is compliant and therefore the counter is compliant. 260 Riverside Restroom Building-110 Restrooms Women's The right and middle soap dispensers have a counter support located directly beneath 309.2,306 Medium 3 In Medium Replace right counter support so the knee space is compliant for the right soap dispenser. E.Riverside Dr. them under the counter.The left soap dispenser is not compliant due to knee height being too low 261 Riverside Restroom Building-110 Restrooms Women's All three mirrors are mounted at a non-compliant height.The right mirror has a bottom 603.3 Medium 3 In High Lower the right mirror so the lowest reflective surface is 40"maximum. E.Riverside Dr. reflective surface height of 44",the middle is 43 5/8",and the left is 43%".The maximum height for the lowest reflective surface of a mirror over a lavatory is 40". 262 Riverside Restroom Building-110 Restrooms Women's There is no compliant ADA stall in the women's side of the restroom building. 604.8 High 3 Out High Reconfigure restroom so there is an ADA compliant stall that is 59"deep and 60"wide E.Riverside Dr. r 263 • Riverside Restroom Building-110 Restrooms Women's There is an ambulatory type stall located in the women's side of the restroom building. 604.8.2 High 3 In and High Reconfigure restroom so there is an ADA compliant stall that is 59"deep and 60"wide.Add ADA E.Riverside Dr. The width of the stall is 41%"which is outside of the required 35-37"width.The door is Out compliant pull handles to stall door.Add self-closing hinges to stall door. not self-closing.The door does not have pull handles. /\ ,.:- 264 Riverside Restroom Building-110 Restrooms Women's The toilet in the ambulatory stall on the women's side of the restroom building is 604.4,604.6 High 3 In and High Reconfigure the stall wall(s)so the toilet is 17-19"from the side walls Adjust the flush button so the E.Riverside Dr. mounted 20%"and 21 Y."from the side walls.The flush button requires 23 5 pounds of Out required force is less than 5 pounds. force which is over the 5-pound maximum. 265 Riverside Restroom Building-110 Restrooms Women's There is no ADA grab bar on the rear of the women's ambulatory stall.The left grab bar 604.5 Medium 3 In Medium Add an ADA compliant grab bar to the rear wall.Adjust the left grab bar so it extends 54"from the E.Riverside Dr. is 52%"from the rear wall and mounted at 26%"in height.The right grab bar is rear wall at a height of 33-36".There should be 12"minimum between the top of the grab bar and mounted at a height of 271/8"and extends 53"from the rear wall. bottom of any object above.Remount grab bar so the height is 33-36"and extends 54"from the rear /1 266 wall. ' a Riverside Restroom Building-110 Restrooms Women's The toilet paper holder is mounted to close to the front of the toilet.The first outlet is 604.7 High 3 In Low Remount the toilet paper holder so the first outlet is 7-9"from the front of the toilet. E.Riverside Dr. 10"behind the front of the toilet.The second outlet is 19"behind the front of the outlet. - • 267 Riverside Restroom Building-110 Restrooms Men's The counter and sinks in the men's side of the restroom building is not compliant.The 606.2 High 3 In Medium remount the counter ortnm the bottom edge of the counter face so there is 27"minimum in knee le""',, ,�'' E.Riverside Dr. counter has a knee clearance height of 26 5/8"-26%"which is less than the 27" clearance height. 1. 268 minimum. ` V Riverside Restroom Building-110 Restrooms Men's There is no compliant ADA stall in the men's side of the restroom building 604.8 High 3 Out High Reconfigure restroom so there is an ADA compliant stall that is 59"deep and 60"wide E.Riverside Dr. 269 Riverside Restroom Building-110 Restrooms Men's There is an ambulatory type stall located in the men's side of the restroom building.The 604.8.2 High 3 In and High Reconfigure restroom so there is an ADA compliant stall that is 59"deep and 60"wide.Add ADA E.Riverside Dr. width of the stall is 42%"which is outside of the required 35-37"width.The door is not Out compliant pull handles to stall door.Add self-closing hinges to stall door. 1 . self-closing.The door does not have a pull handle on the outside.The maneuvering {I! 270 depth is 41"which is less than the 42"minimum. Riverside Restroom Building-110 Restrooms Men's The toilet in the ambulatory stall on the men's side of the restroom building is mounted 604.2,604.6 High 3 In and High Reconfigure the stall wall(s)so the toilet is 17-19"from the side walls Adjust the flush button so the E.Riverside Dr. 22"and 20"from the side walls.The flush button requires 14 pounds of force which is Out required force is less than 5 pounds. over the 5-pound maximum. 271 Riverside Restroom Building-110 Restrooms Men's There is no ADA grab bar on the rear of the men's ambulatory stall.The left grab bar is 604.5 Medium 3 In Medium Add an ADA compliant grab bar to the rear wall.Adjust the grab bars so it extends 54"from the rear E.Riverside Dr. 52"from the rear wall and mounted at 27"in height.The right grab bar is mounted at a wall at a height of 33-36".There should be 12"minimum between the top of the grab bar and height of26It"and extends 51%"from the rear wall.The right grab bar has the toilet bottom of any object above. 272 paper holder mounted 9%"above which is less than the 12"minimum. Riverside Restroom Building-110 Restrooms Men's There is not an ADA compliant urinal present in the men's side of the restroom building. 605.2 High 3 In Low Replace the right urinal with an ADA compliant one that is mounted with a rim height of 17" E.Riverside Dr. The closest ADA compliant urinal has a rim height of 18"which is over the 17"maximum. maximum. The outer face is 12"from the rear wall which is less than the 13%"minimum. 273 Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The Wiest parking lot has 137 total parking space with four ADA parking spaces.None of 208.2 High 1 In Medium Add an additional ADA parking space by the Moraine Avenue restroom building.One of these spaces 215 Moraine Ave. the spaces are marked or sized to be van accessible.According to table 208.2 the total five ADA parking spaces needs to be a van accessible one. number of ADA parking spaces needed is five with one being a van accessible space. 274 Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The ADA parking space in the upper section of the Wiest parking lot by the restroom 502.4 High 1 In Medium Restripe the east row of the Wiest parking lot upper section so there is an ADA compliant parking 215 Moraine Ave. building is not compliant The front of the space has a slope of 3.32%which is over the space with access aisle Following corrective action#1,add the additional ADA parking space needed 2%minimum.Additionally,the space does not have an access aisle.Measuring 138%" at this time 275 wide,the space is less than the 156"minimum Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The right ADA parking space in the lower section of the Wiest parking lot is not compliant.502.2,502.4,502.3 High 1 Out and High The parking space needs to be restnped so the width is 96"minimum.The space needs to be 215 Moraine Ave. The width of the space is 93%"which is less than the 96"minimum.The slope of the In regraded so the slope is less than 2%in any direction.A curb ramp needs to be added to the access space ranges from 3.5%to 5.77%which is over the 2%maximum.The cross-slope ranges aisle so that space is connected to the accessible route. 276 from 2.1%to 2.44%which is over the 2%maximum.The parking space is not connected to the accessible route. Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The middle ADA parking space in the lower section of the Wiest parking lot is not 502.4,502.3 High 1 Out High Regrade the parking space so the slope is less than 2%in any direction.Add a curb ramp to the acres- ' 215 Moraine Ave. compliant.The slope of the space ranges from 2.1%to 3%which is over the 2% aisle so it is connected to the accessible route. maximum.The cross slope in the middle of the space is 3.67%which is over the 2% 277 maximum.The space is not connected to the accessible route. Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The left ADA parking space in the lower section of the Wiest parking lot is not compliant. 502.4,502.3 High 1 Out High Regrade the space so the slope is less than 2%in any direction.Add a curb ramp to the access aisle so 215 Moraine Ave. The slope ranges from 2.44%to 4.37%which is over the 2%maximum.The cross slope of it is connected to the accessible route. - the front of the space is 2.8%which is over the 2%maximum.The space is not connected 278 to the accessible route. Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The right ADA parking space access aisle in the lower section of the Wiest parking lot is 502.4,502.3 High 1 Out High Regrade aisle so the slope is less than 2%in any direction.Add a curb ramp to connect the access 215 Moraine Ave. not compliant.The aisle has a slope that ranges from 2.44%to 4%which is over the 2% aisle to the accessible route. maximum.The aisle is not connected to the accessible route due to a curb. 279 Moraine Ave Restroom Building- Parking Lot Wiest Parking Lot The left ADA parking space access aisle in the lower section of the Wiest parking lot is not 502.4,502.3 High 1 Out High Regrade aisle so the slope is less than 2%in any direction.Add a curb ramp to connect the access ' ' 215 Moraine Ave. compliant.The aisle has a slope that ranges from 3.67%to 5.42%which is over the 2% aisle to the accessible route.maximum.The aisle has a cross-slope that range from 3.84%to 5.42%which is over the 280 2%maximum.The aisle is not connected to the accessible route. Moraine Ave Restroom Building- Accessible Route Around Moraine Ave There is a 6"gap in the sidewalk on the SE corner of the restroom building.The gap is 1" 302.3 High 1 Out or Medium If access is needed,add a cap.Otherwise cover the opening so there is no vertical change or opening 215 Moraine Ave. restroom building deep and has a 3''A"hole(vertical shaft a few feet deep)in the middle of it. In in the ground. 1 Iit _ -' r ` _ 281 Moraine Ave Restroom Building- Accessible Route The sidewalk on the northern edge of the Wiest parking lot that is north of the building 302.3 High 1 In Low Replace grates with ones that have openings less than''A"wide. 11�' 215 Moraine Ave on the north east corner of the lot has non comp)ant elements The section that heads t7 �'��, ,� 1 / 1` / , " ' IM11' downhill towards Moraine Avenue has two large drain grates in the middle of it.These - F 282 grates have openings in them that are 1%"wide.One of the grates has the openings I�,, ,_; I , ,,, elongated with the direction of travel. _ \.,,6� I'I„1 1 Moraine Ave Restroom Building- Accessible Route The sidewalk on the northern edge of the Wiest parking lot that is north of the building 302.3 High 1 In Medium Fill with concrete with no vertical changes over)6". 215 Moraine Ave. on the north east corner of the lot has non-compliant elements.There is a gap between ii the slabs that was sealed in the past,but is open that is%"to 2"in width and over 5"in 283 length.It is elongated in the direction of travel 3 ` • p13 Moraine Ave Restroom Building- Accessible Route The concrete bridge on the north side of the West parking lot lower section has vertical 303.2 High 1 Out Medium Gnnd down the vertical changes at a 1:2 slope to less than%"vertical change. .r*� '1-.+T` „'' �11'1111� 215 Moraine Ave achanges nd'A" to%"on the south side. tit.There are vertical changes of%"to 1"on the north side Y-� -._ 284 and'h"to%"on the south s de. AA i kid Moraine Ave Restroom Building- Accessible Route On the southeast and northwest of restroom building the sidewalk has seams between 303.2 Medium 1 Out or Low Fill or grind down these gaps where no vertical changes over%"is present.Grinding to be done at a 4411 —' 215 Moraine Ave. the concrete slabs that is crumbling and creating some vertical changes around%" In 1:2 ratio - s 285 Moraine Ave Restroom Building- Accessible Route The sidewalk that connects the upper Wiest parking lot motorcycle parking section to the 303.2 Medium 1 Out or Medium Raise cap or grind down edge at a 1.2 slope Y .�. UPDATE:Section was repoured 8/26/2021 and the vertical change issue has been resolved. 215 Moraine Ave. moraine avenue sidewalk has a valve cap that has sunken creating a vertical change of In a11111 L 286 i- Moraine Ave Restroom Building- Accessible Route The sidewalk along the west side of Moraine Avenue has non-compliant vertical changes 303.2 Medium 1 Out or Medium Level brick pavers so vertical changes are less than 33". "' ar 215 Moraine Ave. between the picnic area and the ramp on the northeast corner.There is a brick edging In -• . -1 that has sunken next to an electrical box and has 1"to 1%"vertical changes. ,t 287 Moraine Ave Restroom Building- Accessible Route The sidewalk on the north side of the Wiest parking lot middle section has a concrete slab 303.2 Medium 1 Out Medium Remove and repour slab so vertical changes are less than%"in any direction OR grind down edge eta 215 Moraine Ave. that has sunken creating vertical change of%"to 1%"which is over the%"maximum. 1:2 slope. 288 ♦t,. Moraine Ave Restroom Building- Accessible Route The sidewalk on the northern edge of the Wiest parking lot that is north of the building 303.2 Medium 1 Out Medium Remove and repour slab so vertical changes are less than%"in any direction OR grind down edge ata 215 Moraine Ave. on the north east corner of the lot has non-compliant elements.There is a sunken 1:2 slope. `I' ±v . I concrete slab that is creating vertical change of%"to 134"which is over the A"maximum. 289 Moraine Ave Restroom Budding- Accessible Route The sidewalk on the north side of the Wiest parking lot lower section has flagstone edging 303.2 High 1 Out or Medium Replace missing flagstone and fill non compliant gaps between pavers as well as seal them in place. • °' ./ 215 Moraine Ave with some missing creating vertical changes of 1"to 1%". In "I:WV_j 41.IIIIII-jro, 1111"7---- j a x Moraine Ave Restroom Building- Accessible Route The sidewalk on the west side of the restroom building has section with a 2.27%cross- 403.3 Medium 1 Out High Regrade sidewalk so the cross-slope is less than 2%. ----t34-; yt 215 Moraine Ave. slope which is over the 2%maximum. 291 Moraine Ave Restroom Building- Accessible Route The sidewalk/plaza on the south side of the restroom building has a cross-slope ranging 403.3 Medium 1 Out High Regrade the sidewalk/plaza so the cross-slope is less than 2%and the running slope no more than 5%. s - 215 Moraine Ave. from 2.44%to 4%which is over the 2%maximum. - • 292 Z f Moraine Ave Restroom Building- Accessible Route The sidewalk/plaza on the east side of the restroom building along Moraine Avenue has a 403.3 Medium 1 Out High Regrade the sidewalk/plaza so the cross-slope is less than 2%and the running slope no more than 5%. 215 Moraine Ave. cross-slope ranging from 2.44%to 4.1%which is over the 2%maximum. -� 293 Moraine Ave Restroom Building- Accessible Route The picnic area on the north side of the building has a cross-slope of 2.62%which is over 403.3 Medium 1 Out High Regrade the picnic area so the cross-slope is less than 2%. 215 Moraine Ave. the 2%maximum. 294 Moraine Ave Restroom Building- Accessible Route The plaza area on the north side of the Wiest parking lot upper section by the dumpster 403.3 Medium 1 Out High Regrade this entire area so the running slope is no more than 5%and any cross slope is less than 2%. +" '- - 215 Moraine Ave. and rear of"Green Jeep tours"has a slope of 4.5%to 5 94%which is over the 5% maximum.The landing area for the plaza/sidewalk has a cross slope of 2.3%which is 295 over the 2%maximum Moraine Ave Restroom Building- Curb Ramp The curb ramp at the front of access space one is not compliant.The curb ramp is useless 405.2,406.3,406.4 Medium 1 Out High The curb ramp should be removed and move one space to the north for the new access aisle from 215 Moraine Ave. when a car is parked in the space since it is blocked by the car.The curb ramp itself has a corrective measures Bland 82.The aisle will be shared by two access parking spaces. _ slope of 8.4%to 10.5%which is over the 8.33%maximum.The ramp flares have a slope - 296 of 16.4%for the left one and 20.9%for the right one.The landing area has a cross slope of 2.6%. Moraine Ave Restroom Building- Curb Ramp The curb ramp to the south of access space 1 is not compliant.The slope of the ramp is 405.2,405.5,303.2, Low 1 Out Medium Remove curb ramp and replace with a standard curb.Access to the restroom would be through the - 215 Moraine Ave. 8.4%to 10.5%which is over the 8.33%maximum.The entry to the ramp is only 24" 302 access aisle from corrective measures 81,2,and 23. which is less than the 36"minimum due to the shape and vertical changes.The front of .-,-a " _-- 297 the curb ramp has vertical change of Y."to%".The surface of the ramp is rough with''A" -. deep gaps that are A"to 1"wide. Moraine Ave Restroom Building- Curb Ramp The curb ramp on the east side of the crosswalk by the entry road to the lower section of 303.2,406.4 High 1 Out High The curb ramp needs the front ground down at a 1.2 slope so there is less than''/."vertical change. . 215 Moraine Ave. the Wiest parking lot is not compliant.Theresa Y."vertical lip at the bottom of the The landing area needs to be regraded so the slope is less than 2%in any direction. - - amp.The landing for the ramp has a slope of47%to 4.9%and a cross-Mope of 2.6%to S -Zty„' 298 3.5%which are over the 2%maximum _..9 t • Moraine Ave Restroom Building- Curb Ramp The curb ramp on the west side of the crosswalk by the entry road to the lower section of 405.2,406.3,406.4 High 1 Out Medium The curb ramp needs to be redone to ADA compliant standards.The flares need to be regraded so f I.J \ lig ry,,1Ir,riq 215 Moraine Ave the Wiest kin lot is not compliant.The ram to is 8 4%to 9 45%which s over the the slope less than 8.33%for both.Due to the dumpster enclosure,a ram landing t be ^�L�parking p ramp slope pe is ps p gcanno 833%maximum.The cross slope of the ramp is21%whichis over the 2%maximum. added .�. 299 There is no landing and the ramp has flares of 17.45%for the left flare and 8 9%for the - . right one.With no landing,the maximum slope for the flares is 833%which both are Moraine Ave Restroom Building- Curb Ramp Moraine Ave Crosswalk The west curb ramp for the crosswalk by the restroom building that crosses Moraine 405.2,406.4 High 1 Out High The curb ramp and landing need to be redone to ADA compliant standards. --' _ - - 215 Moraine Ave. Avenue is not compliant.The cross-slope of the ramp is 2.6%to 3.67%which is over the - 2%maximum.The ramp landing has a slope of 3.3%to 3.5%and a cross-slope of 2.4%to - 300 5.1%which are over the 2%maximum. Moraine Ave Restroom Building- Curb Ramp The curb ramp on the south eastern corner of the restroom building which is the north 405.2,406.4 High 1 Out High The curb ramp and landing need to be redone to ADA compliant standards. • 215 Moraine Ave. curb ramp for the upper Wiest entry crosswalk is not compliant.The cross-slope of the \. ramp is 2.8%to 4.2%which is over the 2%maximum.The ramp landing has a slope of 301 2.1%which is just over the 2%maximum. . Moraine Ave Restroom Building- Curb Ramp The curb ramp in the middle of the Wiest lot by the concrete bridge has a non-compliant 406.4 Medium 1 Out High Regrade landing(may need to remove curb ramp entirely)so the slope is less than 2%in any - . '.-N 1 NC _ 215 Moraine Ave. landing.The landing has a slope of 7.34%to 7.87%which is over the 2%maximum. direction. 302 Moraine Ave Restroom Building- Ramps Wood Bridge on west end The wood bridge on the west end of the lower Wiest parking lot section has a slope of 405,40537,405.8 High 1 Out High Both landings need to be regraded so the slope's less than 2%in any direction ADA compliant 215 Moraine Ave of Wiest lot 8.75%to 12.46%for the east half ands considered a ramp.There are no handrails handrails need to be added to both sides of the bridge.A curb barrier needs to be added to the 303 present nor a curb barrier.The slope of the east landing is 314%which is over the 2% bottom railing of the bridge. a - maximum.The slope for the west landing is 5.4%to5.94%which is over the 2% Moraine Ave Restroom Building- Ramps The sidewalk on the upper Wiest parking lot section that connects the motorcycle parking 405,405.7,405.8 Medium 1 Out Medium Remove section of sidewalk.Add a curb ramp to the sidewalk on the south side of the motorcycle : 215 Moraine Ave. area to the Moraine Avenue sidewalk has a slope of 9.28%to 15.48%which makes this parking so this area connects to the accessible route. section a ramp.There are no handrails present.The top ramp landing has a slope of 304 2.27%which is over the 2%maximum.The bottom ramp landing has a slope of 1.92% • and a cross-slope of 8.4%which is over the 2%maximum. Moraine Ave Restroom Building- Ramps The sidewalk along Moraine Avenue from the picnic area to the ramp has a slope of 7.2%405,4057,405.8 High 1 Out High Regrade landings so they are less than 2%slope in any direction.Add ADA compliant handrails to r-. t.". 215 Moraine Ave. to 10.7%which makes it a ramp There are no handrails present.The top ramp landing both sides of the sidewalk. has a slope of 5.77%and a cross-slope of 5 6%which are over the 2%maximum.The 305 bottom ramp landing has a slope of 8.57%and a cross-slope of 2 97%which is over the 2%maximum Moraine Ave Restroom Building- Ramps The sidewalk on the northern edge of the Wiest parking lot that is north of the building 405,405.7,405.8 High 1 Out Medium Add ADA compliant handrails to both sides of the ramp.Regrade the bottom ramp so the slope is less T - 215 Moraine Ave. on the north east corner of the lot has the middle section with a slope of 144%to 171% than 2%in any direction t T which makes it a ramp.There are no handrail present.The bottom ramp landing has a 306 • cross slope of 3.5%which is over the 2%maximum. a a Moraine Ave Restroom Building- Ramps The concrete bridge by the lower section of the Wiest parking lot has a slope of 4.7%to 405,405.7,405.8 High 1 Out High Add handrails to both sides of the bridge.Regrade the north landing so the slope is less than 2%in -I \. _ 215 Moraine Ave. 9.3%which makes it a ramp.There are no handrails present.The north landing has a any direction. slope of 2.62%which is over the 2%maximum. t 307 Ni, .ram - Moraine Ave Restroom Building- Ramps The sidewalk on the north side of the Wiest parking lot middle section has a slope of 405,4057,4058 High 1 Out High Add ADA compliant handrails to both sides of the ramp. 215 Moraine Ave. 4.72%to 8.75%which makes it a ramp.There are no handrail present.The bottom landing is 56"wide which is not as wide as the ramp of 72"wide. 308 Moraine Ave Restroom Building- Entrances Women's The women's restroom entrance is notcompliant.The door is recessed 50"and has 404.2.4,404.2.10 High 1 Out Medium Replace kickplate with one that is 10"high minimum.Add an ADA door opener for the entry door. ��', ! 215 Moraine Ave. maneuvering space width of 4".The minimum maneuvering clearance is 12"wide.The Locate the push button where there is compliant clear floor space. kickplate has a height of 9''A"which is less than the 10"minimum. 309 Moraine Ave Restroom Building- Entrances Men's The men's restroom entrance is not compliant.The door is recessed 50"and has 404.2 4,404.2.8, High 1 Out High Replace kickplate with one that is 10"high minimum.Add an ADA door opener for the entry door. , 215 Moraine Ave. maneuvering space width of 2".The minimum maneuvering clearance is 12"wide The 404.2 10 Locate the push button where there is compliant clear floor space.Regrade outside of the entrance , I f — slope on the outside of the entrance is 3.32%which is over the 2%maximum.The door so the slope is less than 2%in any direction.Adjust the closer so door shuts in S seconds minimum. 310 closes from 90°to 12°in 4.5 seconds which is less than the 5 second minimum.The ' kickplate is 9"high which is less than the 10"minimum. Moraine Ave Restroom Building- Signs Men's The men's side entrance door sign does not have compliant clear floor space with the 703.4 Medium 2 Out Medium Regrade clear floor space so the slope is less than 2%in any direction. 215 Moraine Ave. slope measured at 3.32%which is over the 2%maximum. I 311li .-,-— Moraine Ave Restroom Building- Controls Moraine Ave Crosswalk The crossing lights push button on the west side of the crosswalk across Moraine Ave by 309.2 High 1 Out High Remove raised section so the clear floor space is level at less than 2%slope in any direction. 215 Moraine Ave. the restroom building is not compliant.The button has clear floor space that is 16"deep which is less than the 48"minimum.Additionally,the clear floor space is raised 4"above - 312 the sidewalk/curb ramp. — Moraine Ave Restroom Building- Restrooms Women's The hand dryers in the women's side of the restroom building is not compliant.The clear 309.2 High 3 Out Medium Move one hand dryer to a location that has clear floor space of 30"wide and 48"deep. 215 Moraine Ave. floor space has a depth of 44"which is less than the 48"minimum. 313 Moraine Ave Restroom Building- Restrooms Women's The ADA stall in the women's side of the restroom building has the stall wall height from 604.81.4 Medium 3 Out High Adjust/Modify partitions of ADA stall so the clearance from the ground to the bottom of the - 215 Moraine Ave. the floor to be 43/8"for the side wall and 53/8"for the door These measurements are partition/door is 9"minimum. below the 9"minimum. • 314 Moraine Ave Restroom Building- Restrooms Women's The rear grab bar in the women's ADA stall is not compliant.The grab bar is 11%"to the 604.5 Low 3 In Low Remount grab bar so there is 24"to the open side and 12"to the closed side. 215 Moraine Ave. closed side of the toilet which is just under the 12"minimum with 24"to the open side. ' 315 Moraine Ave Restroom Building- Restrooms Men's The hand dryers in the men's side of the restroom building is not compliant.The clear 309.2 High 3 Out Medium Move one hand dryer to a location that has clear floor space of 30"wide and 48"deep. 215 Moraine Ave. floor space has a depth of 42%"and 43%"which are less than the 48"minimum. 111 316 Moraine Ave Restroom Building- Restrooms Men's The ADA stall in the men's side of the restroom building has the stall wall height from the 604.8.1.2,604.8.1.4 Medium 3 Out Medium Adjust/Modify partitions of ADA stall so the clearance from the ground to the bottom of the �`- - 215 Moraine Ave. floor to be 4%"for the side wall and 534"for the door.These measurements are below partition/door is 9"minimum.Adjust door so it is self-closing fully. the 9"minimum.The door self-closes half way and not fully. 317 Moraine Ave Restroom Building- Restrooms Men's The urinals on the men's side have stall widths of 29"and 29'/."which are less than the 605.3 Medium 3 Out Medium Adjust stall wall of right urinal(Left not compliant due to rim height of urinal)so it is 30"wide f, 215 Moraine Ave. 30"minimum minimum. 318 fi Moraine Ave Restroom Building- Restrooms Men's The grab bars in the men's ADA stall are mounted at a height of 38 1/8"which is over the 604.5 Medium 3 In Medium Remount grab bars to a height of 33"to 36". 215 Moraine Ave. 36"maximum. 319 t"j ----x 1W Tregent Park Restroom Building- Parking Lot Pike Lot The ADA parking space in the Pika lot is not signed as a"Van Accessible"space even 502.6 Low 1 In Low Add"Van Accessible"sign to the parking lot sign 293 W.Elkhorn Ave. though it is the appropriate size. 320 G Tregent Park Restroom Building- Parking Lot Spruce Lot The spruce parking lot does not have the compliant number of ADA parking spaces. 208.2 High 1 In Medium Add an additional ADA parking space so there is one regular ADA space and one"Van Accessible"ADA 293 W.Elkhorn Ave. There is one space located in the spruce parking lot while there are 44 total parking space. spaces.This number of spaces requires 2 ADA parking spaces with one being a"Van _ 321 Accessible"space Tregent Park Restroom Building- Parking Lot Spruce Lot The spruce parking lot ADA space is not compliant.It has a slope that ranges from 6.3% 502.3,502.4 High 1 Out High Regrade parking space so the slope is less than 2%in any direction. 293 W.Elkhorn Ave. to 8.05%which are well above the 2%maximum.The cross-slope ranges from 3.67%to 7.17%which is over the 2%maximum.The ADA space is not connected to the accessible I.. 322 route. .�. Tregent Park Restroom Building- Parking Lot Spruce Lot The spruce parking lot ADA space access aisle is not compliant.The slope of the access 502.3,502.4 High 1 Out High Regrade aisle so the slope is less than 2%in any direction.Add a curb ramp to front of aisle to 293 W.Elkhorn Ave. aisle ranges from 5.4%to 9.45%which is over the 2%maximum.The aisle is not connect it to the accessible route. connected to the accessible route due to no curb ramp present. 323 Tregent Park Restroom Building- Bus Stop Along W.Elkhorn Ave. The bus loading zone on the south side of the Tregent Park restroom building is not 810.2 High 1 Out High Regrade loading and alighting zones so the slope is less than 2%in every direction to the extent "77 .. 293 W.Elkhorn Ave. compliant.The loading zone has a slope of 2.44%in the middle of the zone which is over possible. the 2%maximum.The cross-slope ranges from 2.6%to4.2%which is over the 2% 'r •"L 324 maximum.The alighting area has a slope of 3.32%to 4.2%which is over the 2% --j Tregent Park Restroom Building- Accessible Route Elkhorn Ave.&Spruce Dr There is a water valve cap in the middle of the sidewalk by the Elkhorn Ave and Spruce 302.3,303.2 Medium 1 Out or Medium Add concrete or some surface material that will be stable,firm,and slip resistant around cap to fill - 293 W.Elkhorn Ave. Dr.intersection.The gap around the valve is not compliant and the cap is creating a non- In opening and reduce to cap projection to less than''"with the running slope is less than 5%and the 325 compliant vertical change The opening around the cap is'h"to Y."wide and is elongated cross slope less than 2%in all directions. C ` with the dominate travel direction is some places.The cap projects 3/8"above the � �r sidewalk surface and is not beveled. i/ Tregent Park Restroom Building- Accessible Route Spruce Lot There is a water valve cap in the spruce parking lot ADA parking space.The cap projects 303.2 High 1 Out or Medium Add concrete or some surface material that will be stable,firm,and slip resistant around cap to 293 W.Elkhorn Ave. 1"above the parking lot surface which is over the 33"maximum. In reduce the cap projection to less than%"with the running slope is less than 5%and the cross slope MM. less than 2%in all directions. 326 Tregent Park Restroom Building- Accessible Route Spruce Lot The sidewalk on the south side of the spruce lot complex has several slabs that are 303.2 High 1 Out High Repour sidewalk sections that have heaved or sunken to make sure there is no vertical change over _. s 'R' `% _4. 4 _ • 293 W.Elkhorn Ave. heaving and sinking,creating non-compliant vertical changes. %".Could also grind down vertical changes but will need to watch the slopes and cross slope that are L. V i created to make sure the sidewalk stays in compliance.Part of it fixed 8/26/2021 - 327 Tregent Park Restroom Building- Accessible Route Spruce Dr. The sidewalk along Spruce Dr.has anon-compliant vertical change on the north side of 303.2 Medium 1 Out Medium Repour or grind down so the vertical change is less than''/."with the running slope less than 5%and 293 W.Elkhorn Ave. the roadway bridge.The vertical change is 7/8"which is over the 3/4"maximum. the cross slope less than 2%. 328 h. Tregent Park Restroom Building- Accessible Route Spruce Dr. The sidewalk along Spruce Dr.has a non-compliant vertical change on the south side of 303.2 Medium 1 Out Medium Repour or grind down so the vertical change is less than'A"with the running slope less than 5%and 6 293 W.Elkhorn Ave. the roadway bridge. the cross slope less than 2% 329 ...ir. Tregent Park Restroom Building- Accessible Route Spruce Dr. The are non-compliant vertical changes on the Spruce Dr.sidewalk south of the roadway 303.2 High 1 Out Medium Repour triangle section to reduce vertical change to less than Y4"as well as make sure the landing is r' 293 W.Elkhorn Ave. bridge by the curb ramp to cross Spruce Dr.Concrete section has sunken creating a compliant for the curb ramp at 36"and same width as the ramp for the full length. vertical change of Y."to 1 M"which is over the%"maximum. 330 Tregent Park Restroom Building- Accessible Route Elkhorn Ave.&Spruce Dr.The sidewalk area by the Elkhorn Ave and Spruce Dr intersection has brick edging that has 303.2 High 1 Out or High Level brick pavers so the vertical change is M"maximum. 293 W.Elkhorn Ave. sunken and is creating non-compliant vertical changes.These vertical changes were In , 331 measured at Y."to 1"which is over the'A"maximum. - i Tregent Park Restroom Building- Accessible Route Along W.Elkhorn Ave. The sidewalk along Elkhorn Ave has a broken area by the bus stop that creates a vertical 303.2 High 1 Out or Medium Pull broken pieces and fill gap with new concrete. • . _ ,�+! - __ 293 W.Elkhorn Ave. change or%"to%". In . _ ,- _ — 332 Tregent Park Restroom Building- Accessible Route East of Restroom building One of the concrete slabs in front of the Tregent Park restroom entrances has sunken 303.2 High 1 Out High Pull and repour slab part that has sunken to reduce the vertical change to less than%" It appears this - 293 W.Elkhorn Ave. creating a vertical change of%"to 1"which is over the Y."maximum. has been done a couple times in different section,so may be worthwhile to repour the entire area -. 333 outside the restroom entries to limit the issue from occurring again in the future. Tregent Park Restroom Building- Accessible Route North of Restroom The sidewalk on the north side of the Tregent Park restroom building has a vertical 303.2 Medium 1 Out Medium Repour the concrete section that has sunken. ,y . 293 W.Elkhorn Ave. Building change of%"which is over the%"maximum. ` . . 334 Tregent Park Restroom Building- Accessible Route East of Restroom building The top of the ramp to the lower picnic area has concrete sections that heaved as well as 303.2 High 1 Out Medium Grind down concrete and level pavers. rt. A. 'a 293 W.Elkhorn Ave. brick pavers that have sunken creating a%"to 1 Severtcal change which s over the'''A" '' It j,.: ,"4 335 maximum. _ _ _,.;- Tregent Park Restroom Building- Accessible Route East of Restroom building The eastern stairs to the upper pavilion section have a vertical change at the top 303.2 High 1 Out High Ground down to less than Y."vertical change at no steeper than a 2%grade. , i\H 293 W.Elkhorn Ave. measuring 11/8"which is over the 33"maximum. 336 Tregent Park Restroom Building- Accessible Route East of Restroom building The is a non-compliant vertical change by the artificial turf area.The transition from the 303.2 Medium 1 Out Medium Regrade the turf edge and/or grind the sidewalk edge to reduce the vertical change to%"maximum. .F. 00 293 W.Elkhorn Ave. artificial turf to the concrete sidewalk is 136"which is over the''A"maximum. 6 337 • • Tregent Park Restroom Building- Accessible Route East of Restroom building There is a section of concrete slab in front of the restroom building that has broken and 303.2 Medium 1 Out Medium Pull broken piece and repour concrete. ,k'.. 293 W.Elkhorn Ave. sunken creating a non-compliant vertical change of%". 338 Tregent Park Restroom Building- Accessible Route Spruce Dr. The sidewalk along Spruce Dr.south of the roadway bridge has a section that was cutout,302.3,303.2 N/A N/A N/A N/A Concrete section was repoured in Dec 2021 293 W.Elkhorn Ave. removed,and put back.This section has broken and has a vertical change of 34".The gaps between the sections are 34". 339 Tregent Park Restroom Building- Accessible Route North of Restroom The sidewalk on the north side of the pedestrian bridge from the Spruce parking lot to the 403.3 High 1 Out High Regrade/Reconfigure sidewalk to the running slope is no more than 5%and the cross slope is no mor 293 W.Elkhorn Ave. Building Tregent Park restrooms is not compliant The sidewalk has a slope of 5.1%to 9.3%with than 2%. areas that are up to 125%which are over the 5%maximum running slope.The cross 340 slope was measured up to 13.5%which is well over the 2%maximum. Tregent Park Restroom Building- Accessible Route Spruce Dr. The sidewalk on the east side of the Spruce Dr.roadway bridge has cross slope of 3%to 403.3 Medium 1 Out High Regrade sidewalk so the cross slope is no more than 2%. 293 W.Elkhorn Ave. 3.7%which is over the 2%maximum. 341 Tregent Park Restroom Building- Accessible Route Along W.Elkhorn Ave. The sidewalk along Elkhorn Ave on the south side of Tregent Park restroom building has a 403.3 High 1 Out High Regrade sidewalk so the cross slope is less than 2% 293 W.Elkhorn Ave. cross slope up to 4.7%which is over the 2%maximum. 342 - Tregent Park Restroom Building- Accessible Route West of Restroom The sidewalk along the north side ofthe Pika parking lot is not compliant.There are 403.3 High 1 Out High Regrade the sidewalk so the running slope is less than 5%and the cross-slope is less than 2%. 293 W.Elkhorn Ave. Building sections that have heaved or sunken creating non-compliant slopes and cross-slopes.The • `, sidewalk was measured to have a slope up to 5.1%and a cross slope up to 4.7%. 343 Tregent Park Restroom Building- Accessible Route Along W.Elkhorn Ave. The sidewalk along Elkhorn south of Tregent Park picnic and lawn areas has non- 403.3 High 1 Out High Regrade concrete and level brick pavers so the cross-slope is less than 2%. '' 293 W.Elkhorn Ave. compliant cross slopes.The cross slope was measured to be up to 4.9%which is over the J 2%maximum Additionally,the sidewalk has brick pavers along the edges that have - 344 sunken or heaved that have created cross slopes of 3.8%to 6.1%. Tregent Park Restroom Building- Curb Ramp Pika Lot The curb ramp on the south east corner of the Pika lot by the ADA parking space is not 405.2,406.3 High 1 Out Medium Redo curb ramp so that it is compliant with a running slope less than 5%,a cross-slope less than 2%, 293 W.Elkhorn Ave. compliant.The slope is 14.9%to 15.3%which is over the 5%maximum.The right ramp and compliant ramp flares. _ flare has a 61.3%slope which is well over the 10%maximum when a landing is present. 345 Tregent Park Restroom Building- Curb Ramp Spruce Lot The curb ramp on the south east corner of the Spruce lot parking complex is not 406.2,405.2,406.4 High 1 Out High Redo the curb ramp so the gutter counter slope is 5%maximum.The ramp running slope need to be 293 W.Elkhorn Ave. compliant.The curb ramp has a counter slope of 8 9%which is over the 5%maximum. less than 5%and the cross slope less than 2%.The landing needs to be regraded so the slope and The ramp has a cross slope of 2.3%and a running slope of 7.7%which are over the 2% cross-slope are less than 2%in any direction. 346 and 5%maximums The landing for the curb ramp has a slope of 4.9%to 5.4%which is over the 2%maximum The cross slope of the landing is 2.1%to 2.3%which is over the .14 � 2%maximum Tregent Park Restroom Building- Curb Ramp Spruce Lot The curb ramp on the SW corner of the spruce lot is not compliant.There is a vertical 303.2,406.2,405.2, High 1 Out High The curb ramp needs to be redone so there is no vertical change over Y.",the gutter counter slope MEIN 293 W.Elkhorn Ave. change of 3/8"tot"atthe base ofthe curb ramp.The counter slope is 5.07%which is 406.4 and ramp running slope are less than 5%,the cross slope is less than 2%,and the ramp landing has a just over the 5%maximum.The ramp slope is 6.1%to 10%which is over the 5% slope of less than 2%in any direction. 347 maximum.The cross slope is 2.44%to 5.94%which is over the 2%maximum.The right curb amp flare has a slope of 14.2%which is over the 10%maximum.The curb ramp landing has cross slope of 7.3%to 8.05%which is over the 2%maximum. Tregent Park Restroom Building- Curb Ramp Pike Lot The curb ramp that is northwest of the Pike lot and is the east curb ramp for the Spruce 405.2,406.3,406.4 High 1 Out High The curb ramp needs to be redone so there is no vertical change over%",the gutter counter slope 293 W.Elkhorn Ave. Dr.crosswalk is not compliant.The curb ramp has a running slope of 6.1%to 14.4% and ramp running slope are less than 5%,the cross slope is less than 2%.The ramp landing needs to which is over the 5%maximum The cross slope is 4%to 4.9%which is over the 2% be redone so it is the same width of the ramp for the entire length of the landing and has a slope of 348 maximum.The left ramp flare has a slope of 116%which is over the 10%maximum.The less than 2%in any direction. ramp landing is awkward shaped/sized and has slope of 2.3%to 2.6%with a cross-slope of 4.7%which are over the 2%maximums Tregent Park Restroom Building- Curb Ramp Pika Lot The curb ramp on the west end of the Pike lot on the north side of the crosswalk is not 405.2,406.4 High 1 Out High The curb ramp needs to be redone so the ramp running slope is less than 5%and the cross slope is 293 W.Elkhorn Ave. compliant.The running slope is 6.3%to 8.75%which is over the 5%maximum.The cross less than 2%.The ramp landing needs to be redone so the slope of less than 2%in any direction. slope is 3.14%which is over the 2%maximum.The ramp landing has a slope of 5.4%to 349 6.64%which is over the 2%maximum. Tregent Park Restroom Building- Curb Ramp Elkhorn Ave.&Spruce Dr The curb ramp on the east side of the Elkhorn Ave and Spruce Dr intersection is not 406.2,405.2,406.3, High 1 Out High The curb ramp needs to be redone so the gutter counter slope and ramp running slope are less than 293 W.Elkhorn Ave. compliant.The counter slope is 5.77%which is over the 5%maximum.The running slope 406.4 5%,the cross slope is less than 2%.The ramp landing needs to be redone so it is the same width of is 8.2%to 9.3%which is over the 5%maximum.The cross slope is 1.9%to 3.3%with the the ramp for the entire 36"minimum length of the landing and has a slope of less than 2%in any 350 maximum of 2%allowed.The left ramp flare has a slope of 12.6%which is over the direction • 8.33%maximum due to not having a compliant landing.The ramp landing has a length of 29"to 58"with the minimum being 36"while having the same width as the ramp.The landing has a slope of 6.3%to 7.9%and a cross slope of 3%which are over the maximum • Tregent Park Restroom Building- Ramps East of Restroom building The ramp from the Tregent Park restroom building to the lower picnic and lawn areas is 405.2,405.7,405.8 High 2 Out High Redo the ramp so the running slope is between 8.33%and 10%with a cross slope less than 2%.Add a }....� 293 W.Elkhorn Ave. not compliant.The ramp has a slope of 4.4%to 7.7%for the top half and 10.5%to ADA compliant handrails to both sides of the ramp.Regrade the landing so the slope is less than 2% 11.75%for the bottom half with a compliant range of 8.33%to 10%.The ramp has a in any direction. 1 351 cross slope of 4%to 6.1%for the top half while the bottom half cross slope is 0.5%to 1.75%and the maximum is 2%.There is no handrail present.The landing at the top of ._ the ramp has a slope of 3%which is over the 2%maximum. Tregent Park Restroom Building- Ramps North of Restroom The bridge from the Spruce parking lot to the Tregent Park restrooms has a curve to the 405.2,405.7,405.8 Medium 2 Out High Add ADA compliant handrails to both sides of the bridge.Regrade the landings so the slope is less 293 W.Elkhorn Ave. Building surface that creates a running slope of44%to7.87%which makes'ta ramp.There are than 2%n any direction _ 7 ) no handrails present.The north landing has a slope of 5%to 135%which is over the 2% 't �/ `1 352 maximum The north landing has a cross slope of 135%which is over the 2%maximum. $"*. x( f �t/ The south landing has a slope up to 3.67%which is over the 2%maximum. ,y} � Tregent Park Restroom Building- Stairs East of Restroom building The main stain on the south side of the pavilion from the restroom building to the river 504.2,505 Medium 2 Out Medium Add/Replace with ADA compliant handrails on both sides of the stairs. 293 W.Elkhorn Ave. are not compliant.Due to the stair design,the tread depths are not uniform is some places.There in only one handrail on the north side of the stairs.The handrail has a 353 height at the bottom of the stairs of 3854"which is over the 38"maximum.The handrail extends 6"beyond the bottom user nosing which is less than thell"minimum.The top PM of the handrail does not return to the wall and instead just ends. Tregent Park Restroom Building- Stairs East of Restroom building The stairs on the east side of the pavilion that lead from the pavilion to the Aver are not 504.2,505 Medium 2 Out Medium Add ADA compliant handrails to both sides of the stairs. - - m; 293 W.Elkhorn Ave. compliant.Due to the design of the stairs,the tread depths are not uniform.There are 354 no handrails present. Jm Tregent Park Restroom Building- Stairs East of Restroom building The stairs on the west side of the pavilion that lead to the upper pavilion portion are not 504.2,505 Medium 2 Out Medium Redo stairs so the riser heights are uniform.Add ADA compliant handrails to both sides of the stairs. ..4...,4.a.` • 293 W.Elkhorn Ave. compliant.The users are not uniform with one at 5"and the other at 5%".There are no '' handrails present. 355 • Tregent Park Restroom Building- Stairs East of Restroom building The stairs on the east side of the pavilion that lead to the upper pavilion portion are not 505 Medium 2 Out Medium Add ADA compliant handrails to both sides of stairs. . _ - 293 W.Elkhorn Ave. compliant.There are no handrails present. - . -- t_. 356 Tregent Park Restroom Building- Stairs East of Restroom building The upper section of stairs from lower area to river are not compliant.There are no 505 Medium 2 Out Medium Add ADA compliant handrails to both sides of stairs. 293 W.Elkhorn Ave. handrails present. 357 Tregent Park Restroom Building- Stairs East of Restroom building The lower section of stairs from lower area to over are not compliant.There are no 505 Medium 2 Out Medium Add ADA compliant handrails to both sides of stairs. 293 W.Elkhorn Ave. handrails present. 358 i Tregent Park Restroom Building- Stairs Along W.Elkhorn Ave. The stairs from the Elkhorn Ave sidewalk to the picnic area are not compliant.There are 505 Medium 2 Out Medium Add ADA compliant handrails to both sides of stairs. ;'•y' 293 W.Elkhorn Ave. no handrails. 359 Tregent Park Restroom Building- Entrances Women's and Men's The walls for both entrances are angled and create an awkward maneuvering clearance 404.2.4 Medium 3 Out Medium Add ADA door openers to entry doors. 293 W.Elkhorn Ave. area.The women's side has a depth of 26%". Illigrir- 360 I Tregent Park Restroom Building- Signs Women's The sign on the women's entrance door is not compliant.The pictogram height is 5 SE" 703.6,703.7 Low 3 In Low Replace with an ADA compliant sign that reflects the current ADA status of the restroom 293 W.Elkhorn Ave. while the minimum is 6".Additionally,the sign has the international symbol for accessibility on it while there is no ADA compliant stall in the restroom 361 IL Tregent Park Restroom Building- Signs Men's The sign on the men's entrance door is notcompliant.The pictogram height is SEE"while 703.6,703.7 Low 3 In Low Replace with an ADA compliant sign that reflects the current ADA status of the restroom. 293 W.Elkhorn Ave. the minimum is 6".Additionally,the sign has the international symbol for accessibility on it while there is no ADA compliant stall in the restroom. 362 Tregent Park Restroom Building- Water Fountains East side of Restroom The water fountain clear floor space has a slope of 5.4%which is over the 2%maximum. 602.2,602.7 Medium 3 Out Medium Regrade clear floor space so the slope is less than 2%in any direction Replace with an ADA 293 W.Elkhorn Ave. Building There is only one water fountain set at a sitting height The spout is 14%"from the rear compliant one and add a second water fountain at a standing height that is ADA compliant support which is less than the 15"minimum 363 Tregent Park Restroom Building- Restrooms Women's The women's restroom counter and sink drains are not compliant.The counter height is 606.3,606.5 High 3 In or Medium Adjust or replace counter top so the height of the top is 34"maximum.Add pipe insulation to drain 293 W.Elkhorn Ave. 35"which is over the 34"maximum.The drain pipes are not insulated. Out pipes. ,f 364 Tregent Park Restroom Building- Restrooms Women's The hand dryers in the women's restroom have a clear floor space slope of 2.1%and 309.2 Medium 3 Out High Regrade the floor so the maximum slope is 2%in any direction. - ii 293 W.Elkhorn Ave. 2.6%which is over the 2%maximum 365 Tregent Park Restroom Building- Restrooms Women's The ambulatory/ADA stall in the wornen's restroom is not compliant.The stall 604.8 High 3 Out High Remove solid walls and replace with partition walls.Make stalls appropriate size with one measuring 293 W.Elkhorn Ave. dimensions are 45%"wide and 66%'deep.An ambulatory stall width is 35-37"and an 60"wide and 56"deep.There should be 9"of clearance from the floor to the bottom of theiii,____. ADA stall is 60"wide minimum.This stall does not meet either type and is not compliant. partitions.The door should have ADA pull handles on each side and be self-closing.366 Additionally,the door is not self-closing and does not have ADA pull handles on either side.The door opens to 75°maximum due to the sidewall.The door has 14 15"clearance from the floor,but the walls are solid from the ground up. Tregent Park Restroom Building- Restrooms Women's The toilet located in the women's ambulatory/ADA stall is not compliant The toilet is 22 604.2,604.4,604.6 High 3 Out High Remove solid walls and replace with partition walls to create one stall that is 60"wide and 56"deep. • 293 W.Elkhorn Ave. %"and 23"from the side walls which is outside the 16-18"for ADA stall and 17-19"for an The toilet should be 17-19"from the side wall.The toilet seat height should be 17-19".The flush /'`-'- ambulatory stall.The toilet seat is 20"high from the floor.The flush control requires 7 controls should require maximum 5 pounds of force and be on the open side. • 367 pounds of force and is not on the open side. Tregent Park Restroom Building- Restrooms Women's The women's ambulatory/ADA stall grab bars are not compliant.The left grab bar 604.5,604.7 Medium 3 In Medium Remount grab bars and toilet paper dispenser so that they are all ADA compliant. .5 - 293 W.Elkhorn Ave. extends 53%"from the rear wall which is less than the 54"minimum.There is a toilet i '1 paper dispenser 11%"above the left grab bar which is less than the 12"minimum.The 368 trashcan on the right side is located behind the grab bar. Tregent Park Restroom Building- Restrooms Men's The men's restroom counter and sink drains are not compliant.The counter height is 34 606.3,606.5 High 3 Out or Medium Adjust or replace counter top so the height of the top is 34"maximum.Add pipe insulation to drain ••••mr-..--- 293 W.Elkhorn Ave. %"which is over the 34"maximum.The drain pipes are not insulated. In pipes. 369 Tregent Park Restroom Building- Restrooms Men's The hand dryers in the men's restroom has a clear floor space slope of 2.1%which is over 309.2 Low 3 Out High Regrade the floor so the maximum slope is 2%in any direction. 293 W.Elkhorn Ave. the 2%maximum. 1 ' 370 Tregent Park Restroom Building- Restrooms Men's The ambulatory/ADA stall in the men's restroom is not compliant.The stall dimensions 604.8 High 3 Out High Remove solid walls and replace with partition walls.Make stalls appropriate size with one measuring 293 W.Elkhorn Ave. are 44'A"wide and 66%'deep.An ambulatory stall width is 35-37"and an ADA stall is 60"wide and 56"deep.There should be 9"of clearance from the floor to the bottom of the 60"wide minimum.This stall does not meet either type and is not compliant. partitions.The door should have ADA pull handles on each side and be self-closing. 371 Additionally,the door is not self-closing and does not have ADA pull handles on either side.The door opens to 75°maximum due to the sidewall.The door has 14'''A"clearance from the floor,but the walls are solid from the ground up. Tregent Park Restroom Building- Restrooms Men's The toilet located in the men's ambulatory/ADA stall is not compliant.The toilet is 23" 604.2,604.4,604.6 High 3 Out High Remove solid walls and replace with partition walls to create one stall that is 60"wide and 56"deep. 293 W.Elkhorn Ave. and 22%"from the side walls which is outside the 16-I8"for ADA stall and 17-19"for an The toilet should be 17-19"from the side wall.The toilet seat height should be 17-19".The flush ambulatory stall.The toilet seat is 19%"high from the floor.The flush control requires controls should require maximum 5 pounds of force and be on the open side. 372 7.5 pounds of force and is not an the open side. Tregent Park Restroom Building- Restrooms Men's The urinals in the men's restroom are not compliant.The rim height of the left urinal 605.2 High 3 Out or Medium Remount urinal so the height is 17"or less. 293 W.Elkhorn Ave. from the floor is 17%"high which is over the 17"maximum. In 373 Tregent Park Restroom Building- Restrooms Men's The men's ambulatory/ADA stall has non-compliant grab bar.The left grab bar has a 604.5 Medium 3 In Medium Remount the left bar so the height is between 33"and 36".Remount the toilet paper dispenser so 293 W.Elkhorn Ave. height of 32 7/8"which is outside the 33-36"height range.The toilet paper dispenser is 9 there is 12"minimum between the dispenser and grab bar %"from the right grab bar which is less than the 12"minimum. 374 Tregent Park Restroom Building- Picnic Table Lower Picnic Area The ADA wheelchair space for the picnic table in the lower area is not compliant.The 902.2 Medium 2 Out Medium Regrade the clear floor space so the slope is 2%maximum in any direction. 293 W.Elkhorn Ave. clear floor space has a slope of 2.44%to 5.24%which is over the 2%maximum.The cross slope is 2.1%to 3.84%which is over the 2%maximum. 375 Parking Structure 1- Parking Lot Inside Parking Structure The group of5 east ADA space sign is not compliant with the sign height of 59%"which is 502.6 Low 1 In Low Raise sign so the bottom edge is no less than 60"high. 691 N.St.Vrain Ave. less than the 60"minimum. 376 Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 middle east ADA space is not compliant with a slope of 3.14%at the front 502.4 Medium 1 Out High Regrade space so the slope is less than 2%in any direction. 691 N.St.Vrain Ave of the space which is over the 2%maximum. -■ 377 ,•'' Parking Structure 1- Parking Lot Inside Parking Structure The access aisle between the group of 5 middle east and middle spaces is not compliant. 502.3,502.4 High 1 In and High Regrade aisle so the slope is less than 2%in any direction.Remove bollard to connect the aisle to the V 1 1 1 ' .- +-•1 691 N.St.Vrain Ave. The front of the aisle has a slope of 2.27%which is over the 2%maximum.The aisle is Out accessible route. not connected to the accessible route due to a bollard. 378 Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 middle ADA space is not compliant with a slope of 2.62%at the front of 502.4 Medium 1 Out High Regrade space so the slope is less than 2%in any direction. 691 N.St.Vrain Ave the space which is over the 2%maximum. 379 Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 middle ADA space sign is not compliant with the sign height of 59%" 502.6 Low 1 In Low Raise sign so the bottom edge is no less than 60"high. 691 N.St.Vrain Ave. which is less than the 60"minimum. 380 Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 middle west ADA space is not compliant with a slope of 2.62%at the front 502.4 Medium 1 Out High Regrade space so the slope is less than 2%in any direction. a 'e 691 N.St.Vrain Ave of the space which is over the 2%maximum.The cross slope is 1.92%to 2.27%which is over the 2%maximum ````.111111k. , 381 —/ =.� Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 middle ADA space sign is not compliant with the sign height of 59%" 502.6 Low 1 In Low Raise sign so the bottom edge is no less than 60"high. _ 691 N.St.Vrain Ave. which is less than the 60"minimum. 382 • Parking Structure 1- Parking Lot Inside Parking Structure The access aisle between the group of 5 middle west and west spaces is not compliant. 502.3,502.4 High 1 In and High Regrade aisle so the slope is less than 2%in any direction.Remove bollard to connect the aisle to the 691 N.St.Vrain Ave The front of the aisle has aslope of 2.27%which is over the 2%maximum.The aisle is Out accessible route. i not connected to the accessible route due to a bollard. �. ,,,.,..xr+ 383 Parking Structure 1- Parking Lot Inside Parking Structure The group of 5 west ADA space is not compliant with a slope of 2.44%at the front of the 502.4 Medium 1 Out High Regrade space so the slope is less than 2%in any direction. _ 691 N.St.Vrain Ave. space which is over the 2%maximum. 384 Parking Structure 1- Parking Lot Inside Parking Structure The group of 3 east ADA space is not compliant The width of the space is 953"which is 502.2,502.3,502.4 High 1 In and High Regrade space so the slope is less than 2%in any direction.Restripe space so the width is 96" V I 691 N.St.Vrain Ave less than the 96"minimum.The cross slope of the space is 2.27%to 2.62%which is over Out minimum from centerline to centerline.Connect space to accessible route. _r• ��}, ' the 2%maximum The space is not connected to the accessible route. - / -' ' •-• " 385 _ \' _ Parking Structure 1- Parking Lot Inside Parking Structure The group of3 east ADA space sign is not compliant with the sign height of 52%"which is 502.6 Low 1 In Low Raise sign so the bottom edge is no less than 60"high. 691 N.St.Vrain Ave. less than the 60"minimum. [J C 386 Parking Structure 1- Parking Lot Inside Parking Structure The access aisle between the group of 3 east and middle ADA spaces is not connected to 502.3 High 1 in Medium Remove bollard and relocate bench. e_ 691 N.St.Vrain Ave the accessible route due to a bollard and bench. 4.1011.4r - -' x 387 ' Parking Structure 1- Parking Lot Inside Parking Structure The group of 3 middle ADA space is not connected to the accessible route. 502.3 High 1 In Medium Connect space to the accessible route. I >i 691 N.St.Vrain Ave. 388 Parking Structure 1- Parking Lot Inside Parking Structure The group of 3 middle ADA space sign is not compliant with the sign height of 52 3/8" 502.6 Low 1 In Low Raise sign so the bottom edge is no less than 60"high. _ 691 N.St.Vrain Ave which is less than the 60"minimum. 389 Parking Structure 1- Parking Lot Inside Parking Structure The group of 3 west ADA space is not compliant.The width of the space is 9554"which is 502.2 Medium 1 In Medium Restripe space and aisle so the space is 96"wide minimum and the aisle is 60"wide minimum. •a . L 691 N.St.Vrain Ave. less than the 96"minimum.The space with the aisle has a width of 155%"which is less than the 156"minimum. 390 / Parking Structure 1- Parking Lot PS1 West Lot The west lot ADA space pair east space is not ADA compliant.The space has a cross slope 502.2,502.4 High 1 In Medium Restripe space as an access aisle There are 2 extra ADA spaces than is required so this one can be 0 • ., 691 N.St.Vrain Ave of 1.92%which is just under the 2%maximum.There is a bollard at the front of the space removed.Could also restripe row and move spaces over,but will lose a standard parking space. that protrudes and blocks the entry of the space. `Parking Structure 1- Parking Lot PS1 West Lot The access aisle between the west lot ADA space pair is not compliant.The slope is 2.44%502.4 High 1 Out High Regrade aisle so the slope is less than 2%in any direction. -- • 691 N.St.Vrain Ave. to 2.62%which is over the 2%maximum.The cross slope is 2.1%to 2.44%which is over e_—..-- ..the 2%maximum. 392 Parking Structure 1- Parking Lot PS1 West Lot The west lot ADA space pair west space is not compliant.The slope at the front of the 502.4 Medium 1 Out High Regrade space so the slope is less than 2%in any direction. ,y 691 N.St.Vrain Ave space is 2.27%which is over the 2%maximum.The cross slope in the back of the space is - / ' 2.44%which is over the 2%maximum 393 //�Y 1. '— I - Parking Structure 1- Parking Lot PS1 Front Hill-EV The EV charges are not ADA compliant for the parking space.Slopes range from 1.6%to 502.2,502.4 Low 1 In and High Redo EV charger area so there is a minimum of one space that is also ADA compliant.Add sign to 691 N.St.Vrain Ave. Chargers 2.6%while the cross slopes range from 4.5%to5.6%.The west space width is only 9315" Out mark space as ADA compliant. which is less than the 96"minimum. 394 Parking Structure 1- Accessible Route Sidewalks on North side The sidewalks on the south side of the east pedestrian bridge are not compliant.The east 403.3,405 High 2 Out High Redo sidewalks with straight angle sections instead of curved ones.Curved sidewalks with high slope a 691 N.St.Vrain Ave of PS1 sidewalk has a slope of 4.72%to8.22%and a cross slope up to 2.27%in the middle of the create non-compliant cross-slope due to physics.Best to have straight sidewalks instead of curry _ >r f- length.The west sidewalk has a slope of 4.72%to 7.17%.Any running slope over 5%is a ones Easier to plow and maintain as well.Ramps require handrails,so recommended to keep the :r 395 ramp and the maximum cross slope is 2%. running - _slope below 5%. ` I1 Parking Structure 1 Accessible Route Sidewalks on North side The west end of the pedestrian plaza by the west pedestran bridge has a slope of 8.2%to 403.3,405 High 2 Out High Regrade area to limit running slope to 5%maximum with cross slope less than 2%. jT - — 691N.St.VranAve. of PS1 12.8%and a cross slope of 5.94%to 7.17%.Any running slope over 5%is a ramp and the 1-s-' -✓`Ir'. raa� maximum cross slope is 2%. 7. , 396 1 Parking Structure 1- Accessible Route Sidewalks on North side The pedestrian plaza sidewalk between the east pedestrian bridge sidewalks has non- 403.3 Medium 2 Out Medium Regrade so the cross slope is less than 2% r 691 N.St.Vrain Ave of PSI compliant elements.The cross slope along the north edge of the sidewalk is 3.5%to 4 2% _ which is over the 2%maximum. 397 0I Parking Structure 1- Accessible Route Sidewalks on North side The pedestrian plaza sidewalk on the east side of the parking structure has cross slopes 403.3 Medium 2 Out High Regrade sidewalk so the cross slope is less than 2%. 691 N.St.Vrain Ave. of PS1 measuring 1.92%up to2.62%which is over the 2%maximum. rn 398 Parking Structure l- Accessible Route East Pedestrian Bridge The east pedestrian bridge has a gap between the sidewalk and the bridge on the south 302.3 High 2 In or Medium Fill gap so it is level and any vertical change is less than X". =-- .." 691 N.St.Vrain Ave side.The gap is%"wide and is not elongated in the dominate direction of travel. Out 399 Parking Structure 1 Accessible Route East Pedestrian Bridge There are X"to1X"gaps between the wood boards of the east pedestrian bridge surface 302.3 High 2 In or Medium Fill gap sot is level and any vertical change is less than X". 691 N.St.Vran Ave n the middle of the br dge The gaps are not elongated with the dominate direction of Out 400 travel Parking Structure 1 Accessible Route East Pedestrian Bridge There is a grate in the middle of the east pedestrian bridge with openings in the shape of 302.3 High 2 In or Medium Replace grate with an ADA compliant one and reduce the gap around the grate to less than Y". 691 N.St.Vran Ave a diamond and are 1 Y"in length and%"n width The openings are elongated with the Out /���� ..,d'l� •x''0`'rk"y'. -111011.1 dominate direction of travel There are X"gaps around the grate �r . .Y� 401 '�I.ia'7?A. Parking Structure 1 Accessible Route West Pedestrian Bridge The west pedestrian bridge has a gap between the ramp and the bridge on the south side.302.3 High 2 In or Medium Fill gap sot is level and any vertical change is less than X". 691 N.St.Vran Ave The gap is X"wide ands not elongated in the dominate direction of travel. Out ( \ 402 Parking Structure 1 Accessible Route West Pedestrian Bridge The west pedestrian bridge has several circular areas in the bridge surface that are%" 303.2 High 2 In Medium Fill so the surfaces level - i 691 N.St.Vran Ave deep and lY"wde There is a piece of re barn the middle f the cutout that sticks up Y.". _\,\/f 403 - ---- 'Parking Structure 1 Accessible Route West Pedestrian Bridge The west pedestrian bridge has a steel plate on the north side that is warped.The plate 303.2 High 2 In or Medium Fix plate or replace so the vertical change is less than X". \ 691 N.St.Vran Ave creates a vertical change of 3/8"to Y". Out S*` 404 \�� ' Parking Structure 1 Accessible Route West Pedestrian Bridge The ramp on the south side of the west pedestrian bridge has a concrete slab sinking 303.2 Medium 2 Out Medium Redo concrete slab so it creates a level surface or grind down vertical change at a 1:2 slope V • - 691 N.St.Vran Ave creating a vertical change of Y" ,x 0 .I x,•• t x nj 405 ---... .'.---:1- _ _....—_-_- Parking Structure 1- Accessible Route East Pedestrian Bridge The south side of the east pedestran bridge has the concrete sidewalk X"lower than the 303.2 High 2 Out Medium Raise concrete slab so the vertical change is less than X". 691 N.St.Vrain Ave. metal bridge end. _ 406 s Parking Structure 1 Accessible Route East Pedestrian Bridge The east pedestrian bridge has several areas where the vertical change between the 303.2 High 2 Out High Replace bridge boards that have degraded edges so the transitions between the boards is level. diell'-'-....,t2f,11'b e,,_ � ' M_-. ...v1- 691 N.St.Vrain Ave bridge board's Y"to 1". c _ - 407 - \ >' fly. ,-_ _ . r� - i-'i .- „ Parking Structure 1- Accessible Route East Pedestrian Bridge The east pedestrian bridge has a metal plate on the north end that creates a vertical 303.2 High 2 In or Medium Replace or fix plate so the vertical change is less than X". "`T]�'...- ' - 691 N.St.Vrain Ave change of%" Out 408 Parking Structure 1 Accessible Route Sidewalks on North side The electrical vault cover plates on the south side of the pedestrian plaza have handles 303.2 Medium 2 In or Medium Add covers to the handle gaps or replace cover plates with ADA compliant ones. 691 N.St.Vrain Ave of PS1 that are embedded ina K" %"deep hole that is 3 36"wide. Out _� _ ., 409 ; _ .. Parking Structure 1- Accessible Route Sidewalks on North side There is a water capon the western end of the pedestrian plaza that has sunken creating 303.2 Medium 2 In or Medium Raise cap or grind sidewalk so the vertical change is less than X". i -- '- 691 N.St.Vrain Ave of PS2 a vertical change of 3/8"to O". Out - 410 Parking Structure 1- Curb Ramps PS1 Front Hill The curb ramp by the EV charges has a non-compliant slope of 6.3%to8.75%which is 405.2,406.4 Low 1 Out High Redo curb ramp so it is ADA compliant.Regrade landing so it is less than 2%in any direction. 691 N.St.Vrain Ave. over the 8.33%maximum allowed.The landing has a slope of 2.6%to 4%which is over - the 2%maximum. 411 Parking Structure 1- Curb Ramps PS1 West Lot The curb ramp by the west lot single ADA space is not compliant The slope of the ramp is 405.2,406.4 High 1 Out High Redo curb ramp so it is ADA compliant.Regrade landing so it is less than 2%in any direction. 691 N.St.Vrain Ave 8.4%to 9.28%which is over the 8.33%maximum.The cross slope of the ramp is 2.27% which is over the 2%maximum.The landing has a slope of 8.22%to 1016%and a cross- 412 slope of 2.27%which are over the 2%maximum Parking Structure 1 Ramps West Pedestrian Bridge The ramp for the north side of the west pedestrian bridge is not compliant.The ramp has 405.2,405.7,405.8, High 2 Out High Redo the ramp so the slopes less than 10%and cross slope less than 2%.Add extra curb barriers to r z<~ • I ' +-�� 691 N.St.Vrain Ave aslope up to 1033%which s over the 10%maxmum.The handrail at the bottom of the 405.9 make the ramp compliant.Regrade bottom ramp landing so the slope s less than 2%nany directon. - "t?'1,I ramp extends 0"past the bottom of the ramp which is less than the 12"minimum.The ,MN curb barrier has a 1"gap between the ramp edge and the barrier that is elongated with '// NfC.. 413 the dominate direction of travel The barrier has a height gap of 4'%"which is over the 4" `, - - _ maximum.The bottom ramp landing has a slope of 2.1%and a cross slope of 2.62% which are over the 2%maximum. Parking Structure 1- Ramps West Pedestrian Bridge The ramp for the south side of the west pedestrian bridge is not compliant.The handrails 405.7,405.8 Medium 2 Out Medium Extend handrails so they are 12"past the top and bottom of the ramp.Regrade the bottom ramp r 691 N.St.Vrain Ave. at the bottom ofthe ramp are 3K"short ofthe bottom of the ramp which is less than the landing so the slope is less than 2%in any direction. 12"minimum.The handrails at the top of the ramp are6"short of the bottom of the - 414 ramp which is less than the 12"minimum.The bottom ramp landing has a slope of 2.97% A' which is over the 2%maximum. ------'6111141111.11111.1. Parking Structure 1- Ramps PS1-Reference The driving lane ramps to go between each level of the garage have a slope of 5.9%to 7%N/A 691 N.St.Vrain Ave with a cross slope up to 2.1%. 415 Parking Structure 1 Stairs West Pedestrian Bridge The stars on the north side of the west pedestrian brdge are not compliant.The riser 504.2,505.4,505.10 Medium 2 Out High Replace stairs with ADA compliant ones that have uniform riser heights and tread depths as well as - , - "''',..'•-- e''St 691 N.St.Vrain Ave heights are not uniform and vary from S Y."up to 6".The tread depths are not uniform ADA compliant handrails.Regrade bottom landing so is less than 5%slope and 2%crassslope _ ',z�- A...11 y /46 and vary from 14 K"up to 15 K" s The handrails haves height of 38 K" 40K"which s �a�t r./�` over the38"maxmum The handrails atthe bottom extend13"beyond the last riser,416 requrementsone tread depth,and treads are 14%xt "The handrals at the top are �` w circular with the end eendng 13"beyond the frstrser,however the handrail only '% -' extends 8"before curving downward.The bottom landing of the stairs has a slope of �_���444 -"_ 7.5% Parking Structure 1 Stairs PS1 The east stairwell is not compliant.The handrails are mounted at a height of 36"up to 41505.3,505.4,505.10 High 2 Out High Replace/Adjust handrails so the height is between 34"and 38".The handrails at the bottom of " , _ _ ' rW�.`r: '" .'=11 691 N.St.Vran Ave 34"with the maximum being 38".The outside handrail is not continuous.The top of the section should extend a minimum of one tread depth beyond the last riser.The handrails at the top ' //17 rz,r'- � l�]'.///, �, p, -�- section from first to second has a handrail extending only 8Y."past the frst riser which is of the section should extend a minimum of 12"beyond the first riser. + �_ 1%1 / •s:y less than the 12"minimum.The section from the second floor to the third floor has 417 handrails that do not extend the minimum of one riser nosing at the bottom,measured% K \ ,'s.t� as6 "to9 ".The top of this section has handrails extending 9"past the first riser 99//rr L-` t�, IA" which is less than the 12"minimum.The section from the third level to the fourth level r _. .fi has handrails that extend on 6"to 9 X"past the last riser nosing at the bottom. Parking Structure 1- Stairs PS1 The west stairwell is not compliant.The handrails are mounted at a height of 36"up to 505.4,505.10 High 2 Out High Replace/Adjust handrails so the height is between 34"and 38".The handrails at the bottom of ' !� 691 N.St.Vrain Ave 41% }�"with the maximum being 38".Thetop of the section from first to second has a section should extend a minimum of one tread depth beyond the last riser The handrails at the top - Nip tr. handrail extending only 10%"past the first riser which is less than the 12"minimum.The of the section should extend a minimum of 12"beyond the first riser. -II 418 top of the section from the second floor to the third floor has handrails that extend 11" past the first riser.The top of the section from the third level to the fourth level has ' handrails that extend 10%"and 11%"past the first riser. Parking Structure 1- Signs North Side of PS1 The signs between the east pedestrian bridge sidewalks along the pedestrian plaza have 703.4 Medium 2 Out Medium Regrade clear floor space so the slope is less than 2%in any direction. " ' j - 691 N.St.Vrain Ave. non-compliant clear floor space.The slope ranges from 2.1%to 3.1%which is over the ® 419 2%maximum. _ . Performance Park Restroom and Parking Lot 3 Parking Lot Sections There are 4 ADA parking spaces located in the Performance Park parking lot area which is 208.2 High 1 In Low Add a sign with'Nan Accessible"to a minimum of one ADA parking space that is 132"wide minimum IIU:1/ Amphitheatre the required number.However,none of them are marked as"Van Accessible" with a 60"wide minimum access aisle. ] " F f k 417 W.Elkhorn Ave. 420 1- Performance Park Restroom and Parking Lot Main Lot by Restroom The left ADA parking space by the Performance Park restroom is not compliant.The 502.3,502.4 High 1 Out High Regrade the parking space so the slope is no more than 2%in any direction Add ADA compliant curb :'Y•�,". Amphitheatre- Building slope of the parking space is 2.62%to3.84%which is over the 2%maximum.The cross cut and sidewalk to connect to the accessible route or mark out and regrade a compliant area to 417 W.Elkhorn Ave. slope of the space is 3.84%to 4.54%which is over the 2%maximum.The space is not connect to the curb ramp by the bridge. - 421 connected to the accessible route. Performance Park Restroom and Parking Lot Main Lot by Restroom The right ADA parking space by the Performance Park restroom is not compliant.The 502.3,502.4 High 1 Out High Regrade the parking space so the slope is no more than 2%in any direction.Add ADA compliant curb - ' Amphitheatre- Building slope of the parking space is 2.44%to 3.14%which is over the 2%maximum.The cross cut and sidewalk to connect to the accessible route or mark out and regrade a compliant area to 417 W.Elkhorn Ave. slope of the space is 2.44%to 2.79%which is over the 2%maximum.The space is not connect to the curb ramp by the bridge. 422 connected to the accessible route. Performance Park Restroom and Parking Lot Main Lot by Restroom The access aisle for the ADA parking space pair by the Performance Park restroom is not 502.3,502.4 High 1 Out High Regrade the access aisle so the slope is no more than 2%in any direction.Add ADA compliant curb cu, ' _ :.1 Amphitheatre- Building compliant.The slope of the access aisle is 2.1%to 3.14%which is over the 2%maximum. and sidewalk to connect to the accessible route or mark out and regrade a compliant area to connect ' • • 417 W.Elkhorn Ave. The cross slope of the space is 3.32%to 5.07%which is over the 2%maximum.The space to the curb ramp by the bridge. 423 is not connected to the accessible route. Performance Park Restroom and Parking Lot Main Lot by Restroom The single ADA parking space by the Performance Park restroom is not compliant.The 502.3,502.4 High 1 Out High Regrade the parking space so the slope is no more than 2%in any direction Add ADA compliant curb xb ' ... .MI Amphitheatre- Building slope of the parking space is 2.44%to2.62%which is over the 2%maximum.The cross cut and sidewalk to connect to the accessible route or mark out and regrade a compliant area to ,. '. __- 417 W.Elkhorn Ave. slope of the space is 2.44%to 2.79%which is over the 2%maximum.The space is not connect to the curb ramp by the bridge. - 424 connected to the accessible route. Performance Park Restroom and Parking Lot Main Lot by Restroom The access aisle for the single ADA parking space by the Performance Park restroom is 502.3,502.4 High 1 Out High Regrade the parking space so the slopes no more than 2%in any direction Add ADA compliant curb !L '` Amphitheatre Building not compliant.The cross slope of the access aisle s 2.62%which is over the 2% cut and sidewalk to connect to the accessible route or mark out and regrade a compliant area to _ x . 417 W.Elkhorn Ave. maximum.The space is not connected to the accessible route, connect to the curb ramp by the bridge. v 425 Performance Park Restroom and Parking Lot Main Lot by Restroom There is no sign for the Ada parking space. 502.6 Medium 1 In Medium Add a sign to the ADA parking space with a"Van Accessible"sign and a minimum height of 60". PI• ,, Amphitheatre- Building 417 W.Elkhorn Ave. 426 Performance Park Restroom and Parking Lot East Lot The single ADA parking space by the"Spruce House"Christmas store on the east side of 502.3,502.4 High 1 Out High Regrade the parking space so the slopes no more than 2%in any direction.Add ADA compliant curb - - ; Amphitheatre the parking lot is not compliant.The cross slope n the back of the space is 2 1%which is cut to the access aisle to connect to the accessible route. 4-�,e• +t e Ci f L 417 W.Elkhorn Ave. over the 2%maximum.The space is not connected to the accessible route. 427 .■.rf --. \�Performance Park Restroom and Parking Lot East Lot The single ADA parking space by the Performance Park restroom is not compliant.The 502.3,502.4 High 1 Out High Regrade the access aisle so the slope is no more than 2%in any direction.Add ADA compliant curb cu.L. --bE�- Amphitheatre- cross slope of the space is 3.32%to4.37%which is over the 2%maximum.The space is to the access aisle to connect to the accessible route. - t e. 417 W.Elkhorn Ave. not connected to the accessible route. . -` 428 -- '' Performance Park Restroom and Parking Lot East Lot The sign for the single ADA parking space is in front of the access aisle and not the ADA 502.6 Medium 1 In Medium Move the sign to in front of the ADA parking space.Add a"Van Accessible"sign to the sign with the i Amphitheatre- parking space. bottom height 60"minimum. 417 W.Elkhorn Ave. �-. _ .s• ■ 429 ---tr y < r Performance Park Restroom and Accessible Route Flagstone Sidewalks The trees within the flagstone walkways have grates that are not ADA compliant The 302.3 Medium 2 In or Medium Replace the grates with ones that have an opening that is no more than W inwdth. Amphitheatre openings inthe grates are%"to 1"inwdth and can be elongated with the direction of Out . 417 W.Elkhorn Ave. travel " 430 _ 'L Performance Park Restroom and Accessible Route Stage The drain grate by the Amphitheatre stage is not ADA compliant.The openings are''A"to 302.3 High 2 In or Medium Replace drain grate with an ADA compliant one that has openings less than%"in width. Amphitheatre- over 1"in width which is over the%"maximum. Out I . 417 W.Elkhorn Ave. 431 ,I Performance Park Restroom and Accessible Route Sidewalks-East Side The sidewalk on the north side of the"Spruce House"Christmas shop has non-compliant 307.4 High 2 Out Medium Add a guardrail to the sidewalk along the edge of the"Spruce House"that reduce the sidewalk width ' ° ,05 _ .•' _ Amphitheatre- toward Tregent Park protruding objects.There are bricks that protrude 4"with a bottom height of 48 Y.". 16"and eliminates the protruding objects. - .,R_" 417 W.Elkhorn Ave. Additionally,the gutter has a leading-edge height of 69%"and protrudes 11%"to 15%" - - ' 432 over the sidewalk. II v ' Performance Park Restroom and Accessible Route Sidewalks-Between The sidewalk on the north side of the parking lot island is not compliant.The cross slope 403.3 Medium 2 Out Medium Regrade sidewalk so the maximum cross slope is less than 2%. '• Amphitheatre- parking lot sections of the sidewalk is 2.27%which is over the 2%maximum. . 417 W.Elkhorn Ave. 433 Performance Park Restroom and Accessible Route Sidewalks-Between The sidewalk on the north side of the"Spruce House"Christmas shop is not ADA 403.3 Medium 2 Out High Regrade the sidewalk so the maximum cross slope is less than 2%and the maximum slope is 5%. ■ f Amphitheatre- parking lot sections compliant.The eastern third of the sidewalk near Spruce Dr.has a cross slope up to 3.5% 417 W.Elkhorn Ave. which is over the 2%maximum 400111A- .1 434 Performance Park Restroom and Accessible Route Sidewalks North side of The sidewalk along the north and east perimeter of the Performance Park parking lot is 303.2,403.3 High 2 Out High Regrade the sidewalk so the slope is less than 5%and the cross slope is less than 2%and no vertical 'f [ Amphitheatre parking lots not ADA compliant.The sidewalk has a cross slope that goes up to 2.44%which is over changes over'/.". '` -- ! I- �Y 417 W.Elkhorn Ave. the 2%maximum.There are vertical changes ranging from%"to%"which isover the%" `,-.. __ I 435 1.4maximum. 11 , ~r.c•__ ,� Performance Park Restroom and Accessible Route East Pedestrian Bridge The sidewalk area on the south side of the wood and steel bridge is not ADA compliant. 403.3 High 2 Out High Regrade the sidewalk area,may need to reconfigure with a ramp,so the maximum slope is 5%and ,11g Amphitheatre- The maximum slope ranges from 752%to 9.98%which is over the 5%maximum.The maximum cross slope is 2%. - 417 W.Elkhorn Ave. maximum cross slope ranges from 8.57%to 10.74%which is over the 2%maximum. 436 Performance Park Restroom and Accessible Route East Pedestrian Bridge The slope of the wood and steel bridge is 4.72%to5.77%which makes the bridge a ramp.403.3,405 High 2 Out High Add ADA compliant handrails to the bridge.Regrade both sides of the bridge so the landings have a Amphitheatre- There are no handrails.Both sides of the bridge have landing area that are uneven with slope less than 2%in any direction. . - 417 W.Elkhorn Ave. slopes over the 2%maximum. 437 Performance Park Restroom and Accessible Route Sidewalks-West of The sidewalk on the west side of the Performance Park restroom has a non-compliant 403.3 Medium 2 Out Medium Regrade the sidewalk so the cross slope is less than 2% Amphitheatre- Restroom Building cross slope of 2.44%,which is over the 2%maximum,for the southwestern half of the 417 W.Elkhorn Ave. sidewalk. 438 Performance Park Restroom and Accessible Route West Pedestrian Bridge The concrete bridge has a non-compliant cross slope of 2.62%which is over the 2% 303.2,403.3 High 2 Out High Regrade concrete bridge so the cross slope is less than the 2%maximum and have no vertical changes m - Amphitheatre maximum There are vertical changes on the bridge ranging from%"to 1". over%". - 417 W.Elkhorn Ave. _ 439 �y■. Performance Park Restroom and Accessible Route West Pedestrian Bridge The sidewalk area on the north side of the concrete bridge has a non-compliant cross 403.3 High 2 Out Medium Regrade the area so the cross slope is less than the 2%maximum • - • Amphitheatre- slope that ranges from 2.44%to 6.47%which is over the 2%maximum. ! 417 W.Elkhorn Ave. - - 440 Performance Park Restroom and Accessible Route Sidewalks-West of The sidewalk on the west side of the amphitheater is not compliant with a cross slope 303.2,4033 High 2 Out High Regrade concrete bridge so the cross slope is less than the 2%maximum and have no vertical changes -,-- Amphitheatre- Restroom Building that ranges from 2.27%to3.32%which is over the 2%maximum.There are vertical over)4". 417 W.Elkhorn Ave. changes ranging from%"up to 1%"which are over the%"maximum. 441 Performance Park Restroom and Accessible Route Sidewalks-Behind Stage The sidewalk behind the Performance Park Amphitheatre has a slope of 5.07%which 403.3,405 Medium 2 Out High Regrade the area so the slope is less than 5%and the cross slope is less than 2%. -:k.. Amphitheatre- makes rt a ramp and it does not have any handrails.The cross slope near the west 417 W.Elkhorn Ave. dressing room door is 2.44%which is over the 2%maximum. 442 Performance Park Restroom and Accessible Route Flagstone Sidewalks The picnic table areas are not ADA compliant.The flag stone pathway has slopes up to 302.3,303.2,403.3 High 2 Out High Remove flagstone pavers and use as edging pavers for new stamped concrete walkway for the picnic --" — .'I. Amphitheatre 5.77%which is over the 5%maximum for an accessible route.The cross slopes range table areas.The slope should be less than 5%and cross slope less than 2%with no vertical changes 417 W.Elkhorn Ave. from 4%to857%which are over the 2%maximum.There are gaps between the greater than%" - � 443 flagstone pavers that range from l%"to 2'h"which isover the%"maximum.There are also vertical changes up to l"which is over the%"maximum. Performance Park Restroom and Curb Ramps Near Restroom Building The curb ramp by the performance park restrooms has a non-compliant landing.The 406.4,405.3 High 2 Out High Regrade the top landing of the curb ramp so rt is less than 2%.Additionally,removing and fill the area Amphitheatre- slope of the landing is 2.27%and the top is blocked by landscaping.To go around it,the at the top of the curb ramp so there is an ADA compliant connection from the curb ramp to the - 71 417 W.Elkhorn Ave. cross slope becomes non-compliant. accessible route. 444 Performance Park Restroom and Curb Ramps Sidewalks-Between The east curb ramp of the sidewalk in the middle of the parking lot is not compliant.The 406.3,406.4 Medium 2 Out Medium Redo the curb ramp so the flares have a maximum slope of 10%and the landing has a slope that is Amphitheatre- parking lot sections right flare has a slope of 14.23%which is over the 10%maximum.The landing has a less than 2%in any direction. 417 W.Elkhorn Ave. slope of 2.27%which is over the 2%maximum.The cross slope of the landing is 2.44%to 445 2.97%which is over the 2%maximum Performance Park Restroom and Curb Ramps Sidewalks-Between The middle curb ramp of the sidewalk in the middle of the parking lot is not compliant. 406.2,405.3,406.3 High 2 Out Medium Redo the curb ramp so the flares have a maximum slope of 10%and the landing has a slope that is ' ' ., Amphitheatre- parking lot sections The counter slope is 5.6%which is over the 5%maximum.The cross slope at the bottom less than 2%in any direction.The ramp should have a cross slope less than 2%. 417 W.Elkhorn Ave. of the curb ramp is 2.8%which is over the 2%maximum.The right flare has a slope of 446 13.34%which is over the 10%maximum. Performance Park Restroom and Curb Ramps East side of parking lots The curb ramp on the east side of the parking lot is not compliant.The counter slope is 405.3,406.2,406.3, High 2 Out High Redo the curb ramp so the flares have a maximum slope of 10%and the landing has a slope that is _ — Amphitheatre- 6.47%which is over the 5%maximum The cross slope at the bottom of the curb ramp is 406.4,303.2 less than 2%in any direction.The ramp should have a cross slope less than 2%.Grind the ramp -' 417W.Elkhorn Ave. 2.8%which is over the 2%maximum The right flare has a slope of 13.34%and the left bottom so the vertical change is less than%". 447 flare has a slope of 10.86%which are over the 10%maximum.The landing has a cross slope of 2.62%to 3.84%which is over the 2%maximum.There is also a SS"vertical change at the bottom of the ramp that is not beveled. Performance Park Restroom and Curb Ramps West side of Spruce Dr. The curb ramp on the west side of Spruce Dr.is not compliant.,The cross slope at the 405.3,406.4 High 2 Out High Redo the curb ramp so the ramp has a cross slope less than 2%and the landing has a slope that is less Amphitheatre- bottom of the ramp is 4.02%which is over the 2%maximum.The landing has a slope of than 2%in any direction 417 W.Elkhorn Ave. 3.5%which is over the 2%maximum 448 Performance Park Restroom and Ramps Sidewalks-North side of The sidewalk along the north side of the parking lot has a slope greater than 5%on the 405.2,405.3,405.7, High 2 Out High There are two options that exist.ramp or regrade sidewalk.First option is to regrade west end of the-:- Amphitheatre- parking lots west end making it a ramp.The cross slope of the sidewalk increases to a maximum of 405.8 sidewalk so the cross slope is less than 2%and add ADA compliant handrails.Second option is to 417 W.Elkhorn Ave. 5.42%which is over the 2%maximum.There are no handrails present.The landings on regrade the north sidewalk so the slope is less than 5%,which means it is not a ramp,and the cross 449 both sides are not compliant with cross slopes and slope over the maximum amount slope is less than 2%.Would need to tie sidewalk into area on south of bridge and make sure the allowed, cross slope stays under 2%. Performance Park Restroom and Stairs Behind Restroom Building The stairs behind the Performance Park restrooms have non-compliant handrails.The 505.4 Medium 2 Out Medium Redo the handrails so the height is between 34"and 38". l , Amphitheatre- handrails have a height that is up 39"which is over the 38"maximum 450 417 W.Elkhorn Ave. ,\ Performance Park Restroom and Stairs By East Pedestrian Bridge The flagstone steps on the north side of the wood and steel bridge are not compliant. 504.2,505.4,505.10, High 2 Out High Redo the stairs.Make sure the riser heights and tread depths are uniform.Redo the handrails so the i- E.'.«, t Amphitheatre- The riser heights are not uniform and range from 5'h"to 7".The tread depths are not 302.3 heights are between 34"and 38",extend one tread depth beyond the last user at the bottom,and a - 417 W.Elkhorn Ave. uniform and range from 1155"to 13 54".The handrails have a height up to 39"which is minimum of 12"beyond the first riser nosing at the top.Make sure flagstones are set closely 451 over the 38"maximum.The handrails do not extend one tread depth beyond the last together and grout if necessary to prevent any gap from being more than%"in width. �- ':' - --er at the bottom.There are also gaps between the flagstones that make the steps that -. Yyr -._ are over'A"in width, Performance Park Restroom and Stairs East side of lawn seating The north set of stairs in the lawn seating area have non-compliant handrails The 505.5,505.10 Medium 2 Out Medium Redo the handrails so the heights are between 34"and 38",extend one tread depth beyond the last - ',;_ - Amphitheatre- handrails extend 8%"and 1044"beyond that last riser at the bottom which is less than riser at the bottom,and a minimum of 12"beyond the first riser nosing at the top.There should be a 417 W.Elkhorn Ave. the 12"tread depth minimum.The handrails extend 11%"beyond the last riser nosing at minimum of 1%"gap between the handrail and adjacent surface. ,- 452 the top which is less than the 12"minimum.The handrail on the right side has a 5/8"gap between the handrail and adjacent surface which is less than the 1''A"minimum. Performance Park Restroom and Stairs East side of lawn seating The south set of stairs in the lawn seating area have non-compliant handrails.The right 505.4,505.5,505.10, High 2 Out Medium Redo the handrails so the heights are between 34"and 38",extend one tread depth beyond the last . R Amphitheatre handrail extends 7 IS"beyond that last rser at the bottom which is less than the 12"tread 302.3 riser at the bottom,and a minimum ofl2"beyond the first riser nosing at the top.There should be a ,. 1W:417 W.Elkhorn Ave. depth minimum.The handrails have a IS"and 1"gap between the handrail and adjacent minimum of 1'h"gap between the handrail and adjacent surface Grout between the flagstones so 453 surface which is less than the 135"minimum.The handrails have a maximum height of 38 there is less than a%"gap between flagstones. - 'h"which is over the 38"maximum.There are gaps between the flagstones that make the steps that are over IS"wide. - T Performance Park Restroom and Stairs Picnic Table Area The east set of stairs in the picnic table area have non-compliant handrails.There is only 505.2,505.10 Medium 2 Out Medium Remove the current handrail and install ADA compliant handrails on both sides of the stairsthat "'. Amphitheatre- one handrail on the west side.The handrail does not extend one tread depth beyond the extend one tread depth beyond the last rser at the bottom and a minimum of 12"beyond the first �- ' 417 W.Elkhorn Ave. last riser at the bottom. riser nosing at the top. /- 454 Performance Park Restroom and Stairs Picnic Table Area The middle set of stairs in the picnic table area are not compliant The riser heights are 504.2,505.2 High 2 Out High Redo stairs so the riser heights are uniform.Add an ADA compliant handrail to the west side of the '.1'. Amphitheatre- not uniform and range from 4'h"to6''".There is only one handrail on the east side of stairs. -�ti�, -- 417 W.Elkhorn Ave. the stairs. 455 - .-% Performance Park Restroom and Stairs Picnic Table Area The west stairs of the picnic table area are not compliant.Theriser heights are not 504.2,505.10 High 2 Out High Redo the stairs so the riser heights and tread depths are uniform.Replace the handrail with ADAAmphitheatre- uniform and range from 6"to 7".The tread depths are not uniform and range from 11" compliant one that extend one tread depth beyond the last riser at the bottom and a minimum of 12" 417 W.Elkhorn Ave. to 12".The handrails do not extend one tread depth beyond the last riser nosing at the beyond the first riser nosing at the top. ` 456 bottom or 12"minimum beyond the last riser nosing at the top. Performance Park Restroom and Picnic Tables Picnic Table Area There is one picnic table that has a wheelchair space.The clear floor space has a slope of 902.2 Medium 4 Out High Regrade wheelchair clear floor space so the slope is less than 2%in any direction. ---' Amphitheatre- 3.5%and a cross slope of 5.94%which are over the 2%maximum 417 W.Elkhorn Ave. 457 Performance Park Restroom and Entrances Women's Restroom The women's side restroom entrance does not have maneuvering clearances that are 404.24 High 3 Out Medium Add ADA door openers to both sides of the door. '- ' Amphitheatre- ADA compliant The put side of the door has a depth of 43%"which is less than the 60" 417 W.Elkhorn Ave. minimum.The push side of the door has 1%"width which is less than the 12"minimum 458 for a door with a closer. Performance Park Restroom and Entrances Men's Restroom The men's side restroom entrance does not have maneuvering clearances that are ADA 404.2.4,404.2.8 High 3 Out Medium Add ADA door openers to both sides of the door. F Amphitheatre- compliant.The put side of the door has a depth of 44"which is less than the 60" _ 417 W.Elkhorn Ave. minimum.The push side of the door has 2"width which is less than the 12"minimum for 459 a door with a closer.The door closes too quickly from 90°to 12°at 1.5 seconds which is less than the 5 second minimum. Performance Park Restroom and Entrances Dressing Rooms The dressing room doors of the amphitheater close too quickly from 90'to 12'at 3.5 404.28 High 2 In Low Adjust the door closers so the doors close from 90°to 12°in no less than 5 seconds. Amphitheatre- seconds for both doors which is less than the 5 second minimum. t I iIt 417 W.Elkhorn Ave. It 460 1i Performance Park Restroom and Signs Men's Restroom The men's restroom sign is not Ada compliant.The sign does not have any braille or 703.2,703.3,703.4, High 2 In Medium Replace sign with an ADA compliant one mounted with a baseline height of 48"to 60". Amphitheatre- raised letters.The text has a baseline height of 60 5"which is over the 60"maximum. 703.6 l 417 W.Elkhorn Ave. The pictogram has a height of 5 1/8"which is less than the 6"minimum. 461 Performance Park Restroom and Signs Women's Restroom The women's restroom sign is not Ada compliant.The sign does not have any braille or 703.2,703.3,703.4, High 2 In Medium Replace sign with an ADA compliant one mounted with a baseline height of 48"to 60". Amphitheatre- raised letters.The text has a baseline height of 60 Vi"which is over the 60"maximum. 703.6 , 417 W.Elkhorn Ave. The pictogram has a height of 5"which is less than the 6"minimum 462 t Performance Park Restroom and Signs Restroom Building The Performance Park restroom closes every winter and has a sign that is not ADA 703 High 2 In Medium Add signs that can cover permanent restroom signs with a minimum of stating'The restrooms are Amphitheatre- compliant directing to the nearest restroom. closed for the winter",prefer"Restrooms closed for winter,use Tregent Restrooms to the East". 417 W.Elkhorn Ave. 463 Performance Park Restroom and Water Fountains Restroom Building The left water fountain requires 14 pounds of force to operate which is over the 5-pound 602.3,602.6 Medium 3 Out Low Replace water fountain with an ADA compliant one for exterior application. YII Amphitheatre- maximum.The water flow is minimal and not ADA compliant. 417 W.Elkhorn Ave. Itliel 464 ■ Performance Park Restroom and Water Fountains Restroom Building The right water fountain requires 8 pounds of force to operate which is over the 5-pound 602.2,602.3,602.6 Medium 3 Out Low Replace water fountain with an ADA compliant one for exterior application. il: Amphitheatre- maximum.The knee height is 25%"which is under the 27"minimum.The water flow is geliogaii 417 W.Elkhorn Ave. minimal and not ADA compliant. 465 i Performance Park Restroom and Restrooms Women's The interior accessible path of the Women's side of the restroom building by the ADA 403.3 Medium 3 Out High Regrade restroom floor surface so the running slope is no more than 5%and the cross slope is no Amphitheatre- restroom stall has a non-compliant cross-slope of3.14%which is over the 2%maximum. more than 2%. 'i - 417 W.Elkhorn Ave. .r_- - 466 Performance Park Restroom and Restrooms Women's The ADA stall compartment on the women's Ade of the restroom building is not 604.8.1.1 Medium 3 Out Medium Reconfigure the stall so the door is 4"maximum from the wall.The door needs to be self-closing and — Amphitheatre- compliant.The entry door is on the partition sidewall and is 5 X"from the wall which is have ADA pull handles on both sides. 417 W.Elkhorn Ave. over the 4"maximum.The door is not self-closing.The door has pull handles on the pull 467 side only. Performance Park Restroom and Restrooms Men's The ADA stall compartment on the men's side of the restroom building is not compliant. 604.8 1.1 Medium 3 Out Medium Reconfigure the stall so the door is 4"maximum from the wall.The door needs to be self-closing and Amphitheatre- The entry door is on the partition sidewall and is 5 7/8"from the wall which is over the 4" have ADA pull handles on both sides 417 W.Elkhorn Ave. maximum.The door is not self-closing.The door has pull handles on the pull side only. 468 Performance Park Restroom and Restrooms Men's The men's side of the restroom building has a countertop and sinks heights of 341/8" 606.3 Low 3 In Medium Remount counter with the top height of 34"maximum. Amphitheatre- which is over the 34"maximum. 417 W.Elkhorn Ave. ' 7... 469 Performance Park Restroom and Restrooms Men's The men's ADA stall toilet requires 7 pounds of force to operate which is over the 5- 604.6 Medium 3 In or Medium Adjust flush control so it requires no more than 5 pounds to operate. Amphitheatre- pound maximum. Out 417 W.Elkhorn Ave. 470 Performance Park Restroom and Restrooms Men's There is no ADA compliant urinal on the men's side of the restroom building.The right 605.2.605.3 High 3 Out Medium Replace the right urinal with an ADA compliant one. Amphitheatre- urinal is at the proper height,but the clear floor space has a slope of 3.84%and a cross- I` 417 W.Elkhorn Ave. slope of 2.1%which are over the 2%maximum.The rim depth from the rear support is 471 12 X"which is less than the 13%"minimum. Performance Park Restroom and Restrooms Men's The ADA grab bars in the ADA stall on the men's side of the restroom building are not 604.5 High 3 In Medium Remount grab bars to a height of 36"maximum Amphitheatre- compliant.The side grab bar has a height of 37''A"and the rear bar has a height of 37". ` 417 W.Elkhorn Ave. The maximum height of the top of the grab bars is 36".472 Performance Park Restroom and Restrooms Men's The ADA stall toilet paper dispenser in the men's Ade of the restroom building has the 604.7 Medium 3 In Low Remount toilet paper dispenser so one of the dispenser outlets is in an ADA compliant range of 7-9" Amphitheatre- outlet distance too far from the front of the toilet at 12"and 17 X"which are outside of from the front of the toilet. 417 W.Elkhorn Ave. the 7-9"compliant range. 473 Visitor Center- Parking Lot East Parking Lot The north ADA space of the east side north pair is not compliant.The ADA space has a 502.4 High 1 Out High Regrade the ADA parking space so the slope is less than 2%in any direction. 500 Big Thompson Ave. slope of 3.14%to 3.67%which is over the 2%maximum.The cross slope in the middle of "t the space is 2.27%which is over the 2%maximum. - 474 Visitor Center- Parking Lot East Parking Lot The access aisle for the east side north pair is not compliant.The slope is 3.67%to4.9% 502.4 High 1 Out High Regrade the ADA access aisle so the slope is less than 2%in any direction. • • _ 500 Big Thompson Ave which is over the 2%maximum.The cross slope is 2.44%to 2.97%which is over the 2% 475 maximum. Visitor Center- Parking Lot East Parking Lot The south ADA space of the east side north pair is not compliant.The ADA space has a 502.4 High 1 Out High Regrade the ADA parking space so the slope is less than 2%in any direction. 500 Big Thompson Ave. slope of 1.92%to 3.32%which is over the 2%maximum. S 476 Visitor Center- Parking Lot East Parking Lot The south ADA space of the east side north pair does not have a sign. 502.6 Medium 1 In Medium Add an accessible parking space sign that is a minimum of 60"in height for the sign bottom from the SOO Big Thompson Ave ground -D 477 Visitor Center- Parking Lot East Parking Lot The north ADA space of the east side south pair is not compliant.The ADA space has a 502.4 Medium 1 Out High Regrade the ADA parking space so the slope is less than 2%in any direction. - Et 500 Big Thompson Ave. slope of 2.1%at the front of the space which is over the 2%maximum. - 478 Visitor Center- Parking Lot East Parking Lot The access aisle for the east side south pair is not compliant The slope is 2.62%to 3.32%502.4 High 1 Out High Regrade the ADA parking space so the slope is less than 2%in any direction. 500 Big Thompson Ave which is over the 2%maximum.The cross slope is 2.27%which is over the 2%maximum. - 479 Visitor Center- Parking Lot East Parking Lot The south ADA space of the east side south pair is not compliant.The ADA space has a 502.4 High 1 Out High Regrade the ADA parking space so the slope is less than 2%in any direction. 500 Big Thompson Ave. slope of 2.4%to 3.14%which is over the 2%maximum. - 480 Visitor Center- Parking Lot East Parking Lot The east side south pair ADA access spaces do not have an access sign. 502.6 Medium 1 In Medium Add an access sign to both ADA spaces that is 60"for the sign bottom height. T 1-..'16MWA. 500 Big Thompson Ave 481 ..�.r. `. W Visitor Center- Parking Lot Northwest of Visitor The west ADA parking space in the group of four is not compliant.The slope and cross 502.4 Medium 1 Out Medium Regrade the ADA parking space so the slope is less than 2%in any direction. 4[i: --- 500 Big Thompson Ave. Center slope are 2.1%in the middle of the space which is over the 2%maximum. i 482 Visitor Center Parking Lot West Parking Lot The single ADA space on the east side of the parking lot is not compliant The slope is 502.4 High 1 In Medium The space's unnecessary and has a very rough parking surface that needs to be redone.Remove _;t„,A.t._,a c'. _ _ 500 Big Thompson Ave 1281%and cross slopes 6.3%which are over the 2%maximum space reducing number of ADA parking spaces to 8 which is 2 more than required.Removing the >r. space and the access aisle would add two parking space to the lot along with removing the _483 unnecessaryaccessa'sI farther east creating 3 additional parking spaces total. - i 411 • Visitor Center- Parking Lot West Parking Lot The access aisle for the single ADA parking space is not compliant.The cross slope of the 502.4 High 1 In Medium Remove access aisle. 500 Big Thompson Ave. access aisle is 2.44%to 2.62%which is over the 2%maximum. 484 Visitor Center- Parking Lot West Parking Lot The single ADA access space does not have an access sign. 502.6 Medium 1 In Low Add sign if space stays,otherwise nothing to be done if space is removed. • 500 Big Thompson Ave • 485 Visitor Center- Bus Loading Zone North side of Visitor The alighting area for the bus lane on the north side of the Visitor Center is not 810.2 High 1 Out High Regrade sidewalk so the slope is less than 2%in any direction and the depth perpendicular to the bus 500 Big Thompson Ave. center compliant.The depth of the area is 100",but narrows to 83"due to a bench and this is loading zone is 96"minimum.Relocate bench so it does not block any sidewalk area. less than the 96"minimum.The slope of the area is 2.1%to 3.67%which is over the 2% 486 maximum. Visitor Center- Accessible Route Sidewalks-North side of The sidewalk on the west side of the north entry is non-compliant with a cross slope of 403.3 High 1 Out Medium Regrade this section of sidewalk so the running slope is no more than 5%and the cross slope is less - 500 Big Thompson Ave Visitor Center 2.62%which is over the 2%maximum than 2%. 487 Visitor Center- Accessible Route Sidewalks-North side of The sidewalk by the group of 4 ADA parking spaces is non-compliant.Due to the curb 403.3,403.5 High 1 Out Medium Widen the sidewalk to the south at the top of the curb ramps so there is at least 36"of sidewalk with - - 500 Big Thompson Ave. Visitor Center ramps present,the cross slope is 2.1%to5.94%which is over the 2%maximum. a cross slope less than 2%and running slope of 5%. • Additionally,the level portion of the sidewalk at the top of the curb ramp narrows to 31" 488 wide. Visitor Center- Accessible Route Sidewalks-West of The sidewalk by the single ADA parking space is non-compliant with a cross slope is 2.27%403.3 Medium 1 Out High Regrade sidewalk so the cross slope is less than 2% - ; .. 'grit ' 500 Big Thompson Ave Visitor Center which is over the 2%maximum. Si= 489 _ _ Visitor Center Accessible Route Sidewalks-South Portico The sidewalk under the South portico is noncompliant with a cross slope of 2.79%which 403.3 High 1 Out High Regrade sidewalk so the cross slope is less than 2%. f - _ I'. 500 Big Thompson Ave is over the 2%maximum. 490 21f� ,t t k j`r Visitor Center- Accessible Route Sidewalks-South of The sidewalk on the north side of the east pedestrian bridge has a non-compliant vertical 303.2 Medium 1 In Medium Fill missing part of sidewalk so the vertical change is no more than 0". SOO Big Thompson Ave Visitor Center change by where the sidewalk curves.There is a section of sidewalk that is - r. V broken/crumbling and is creating a%"vertical change.The section that is missing is 4" ' /' 491 wide and 2014"long. - ( / Visitor Center- Accessible Route Sidewalks-South of The sidewalk west of the south entrance has a non-compliant vertical change of%"to%" 303.2 Medium 1 Out Medium Bevel sidewalk edges or remove sidewalk and repour.Transition between sidewalk section must hay. ` • 500 Big Thompson Ave Visitor Center due to a section of sidewalk heaving. a vertical change that is less than Y.". _ • - , 492 Visitor Center- Accessible Route Sidewalks-West of The transition for the single ADA parking space access aisle to the accessible route has a 303.2 High 1 In Medium If access space is staying,fill low area so there is less than a 1/4"vertical change.If access space is -- - 500 Big Thompson Ave. Visitor Centernon-compliant vertical change.The access aisle surface is degrading creating a N"vertical removed,this can be ignored for ADA purposes. change at the transition between the aisle and sidewalk. w,- 493 Visitor Center- Accessible Route Sidewalks-West of There is a section of sidewalk that was cut out and has been filled with gravel.Gravel is 302.1 Medium 1 In or Low Fill in cutout with concrete so there is a vertical change of no more than'''A" 500 Big Thompson Ave Visitor Center not a compliant accessible route surface due to not be stable or firm.There is also a Out - _ vertical change present that is%". - 494 -- Visitor Center- Curb Ramps East of Visitor Center The curb ramp for the east side north ADA parking space pair in not compliant.The slope 405.2,406.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8.33%and maximum cross slope of 500 BigThom Ave. of the curb ramp8.2%to 8.4%which is over the 8.33%maximum.The left flare has a 705 2%.The rampflares should be less than 10%with a landing8.33%without a landing.Replace S • .r •II Thompsonis or p slope of 8.75%which is over the maximum of 8.33%for a curb ramp with no landing.The plastic truncated domes plate with a metal version. 495 landing is blocked by a planter and bench.The truncated dames have been mostly shaved down. Visitor Center- Curb Ramps East of Visitor Center The curb ramp for the east side south ADA parking space pair in not compliant.The slope 405.2,406.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8 33%and maximum cross slope of \• _ 500 Big Thompson Ave of the curb ramp is 8.4%to 8.92%which is over the 8.33%maximum.The right flare has 705 2%The ramp flares should be less than 10%with a landing or 8.33%without a landing.Regrade i ' ' a slope of 10.86%which is over the 10%maximum.The landing has a cross slope of landing so the slope is less than 2%in any direction Replace plastic truncated domes plate with a 496 2.27%and a slope of 2.1%which are over the 2%maximum The truncated domes have metal version - been mostly shaved down. Visitor Center- Curb Ramps Northwest of Visitor The east curb ramp for the group of 4 ADA parking spaces is not compliant.The landing 406.4,705 High 1 Out High Landing will be fixed with corrective measure 815 as long as the slope is less than 2%in any direction. 500 Big Thompson Ave. Center has a length of 32"which is less than the 36"minimum.The truncated domes have been Replace plastic truncated domes plate with a metal version. 497 mostly shaved down. Visitor Center- Curb Ramps Northwest of Visitor The west curb ramp for the group of 4 ADA parking spaces is not compliant.The landing 406.4 High 1 Out High Landing will be fixed with corrective measure H15 as long as the slope is less than 2%in any direction 500 Big Thompson Ave Center has a length of 30%"which is less than the 36"minimum.The truncated domes have Replace plastic truncated domes plate with a metal version. been mostly shaved down. 498 Visitor Center- Curb Ramps Northeast of Visitor The south curb ramp for the crosswalk on the northeast corner of the Visitor Center is 405.3,406.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum cross slope of 2%.Add a ramp landing to the '0"- J. r 500 Big Thompson Ave. Center not compliant.The cross slope is 2.27%to 3.14%which is over the 2%maximum.The 705 top of the curb ramp and connect it to the accessible route.Replace plastic truncated domes plate „\1- 'C'"' right flare is 12.1%which is over the 8.33%maximum.There is no ramp landing.The with a metal version. _ 499 truncated domes have been mostly shaved down. Visitor Center- Curb Ramps Northeast of Visitor The north curb ramp for the crosswalk on the northeast corner of the Visitor Center is not 405.2,405.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8 33%and maximum cross slope of _ -,---. 500 Big Thompson Ave Center compliant.The ramp has a slope of 18.9%at the front which is over the 8.33% 705 2% Redo the ramp landing so the slope is less than 2%in any direction.Replace plastic truncated - - maximum.The cross slope is 2.7%to 3.5%which is over the 2%maximum.The ramp domes plate with a metal version - _' 500 landing has a slope of 3.3%to4%and a cross slope of 2.1%which are over the 2% __ maximum.The truncated domes have been mostly shaved down. - .. Visitor Center- Curb Ramps Northeast of Visitor The south curb ramp for the east side north crosswalk is not compliant.The ramp slope is 405.2,405.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8.33%and maximum cross slope of 500 Big Thompson Ave. Center 8.22%to 11.4%which is over the 8.33%maximum.The cross slope is 2.1%which is over 705 2%.Redo the ramp landing so the slope is less than 2%in any direction.Replace plastic truncated the 2%maximum.The landing has a slope of 6.7%to 7%which is over the 2%maximum. domes plate with a metal version. 501 The truncated domes have been mostly shaved down. Visitor Center- Curb Ramps Northeast of Visitor The north curb ramp for the east side north crosswalk is not compliant The ramp slope is 405.2,405.3,406.4, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8 33%and maximum cross slope of 500 Big Thompson Ave Center 13.34%at the front which is over the 8.33%maximum.The cross slope is 2.1%which is 705,3032 2% Redo the ramp landing so the slope is less than 2%in any direction.Replace plastic truncated *7r ~- over the 2%maximum The landing has a slope of 2.62%to314%which is over the 2% domes plate with a metal version Eliminate vertical changes over%". 502 maximum.The truncated domes have been mostly shaved down.There is a vertical change of%"at the ramp start. Visitor Center- Curb Ramps By North Entry of Visitor The curb ramp for the north entrance of the Visitor Center is not compliant.The ramp 405.2,405.3,406.3, High 1 Out High Redo curb ramp so it is ADA compliant with a maximum slope of 8.33%and maximum cross slope of . 500 Big Thompson Ave. Center slope is 11.57%to 12.1%which is over the 8.33%maximum.The cross slope is 2.27% 705 2%.Ramp flares should have a maximum slope of 10%.Replace plastic truncated domes plate with a which is over the 2%maximum.The left flare has a slope of 12.46%and the right has a metal version. 503 slope of 11.92%which are over the 10%maximum.The truncated domes have been mostly shaved down. Visitor Center- Curb Ramps Northwest of Visitor The south curb ramp for the west parking lot crosswalk is oddly shaped.The truncated 406,705 Low 1 Out Medium Replace plastic truncated domes plate with a metal version. 500 Big Thompson Ave Center domes have been mostly shaved down 504 Visitor Center- Curb Ramps Northwest of Visitor The north curb ramp for the west parking lot crosswalk has the truncated domes have 705 Low 1 Out Medium Replace plastic truncated domes plate with a metal version. 500 Big Thompson Ave. Center been mostly shaved down. 505 Visitor Center- Ramps Bus Loading Zone The curb ramp in the middle of the bus lane has the east flare with a slope of 9.63%which 405.2,405.7,405.8 Medium 1 Out High Regrade the east ramp flare so the slope is less than 5%and will no longer be considered a ramp. 500 Big Thompson Ave makes this section of the sidewalk a ramp.The ramp height is 6%"so handrails are required.The bottom landing has a cross slope of 2.97%which is over the 2%maximum 506 The top slope is narrower than the ramp at 83"due to a bench and the cross slope is _ 2.62%which is over the 2%maximum • Visitor Center- Stairs Call Center The stairway in the call center has non-compliant handrails.The handrails have a height 505.4,505.10 Medium 2 Out Medium Remount handrails to an ADA compliant height of 34"to 38".Extend the right handrail so it is a 500 Big Thompson Ave. of 38%"to41".The right handrail extends only 6"beyond the last riser at the bottom minimum of 12"past the last riser at the bottom of the stairs. which is less than the 12"minimum. 507 Visitor Center- Elevator Call Center The elevator in the call center area is not compliant The door is offset and has a width of 407.4 3 High 2 Out High Add a gap filler for the floor gap.Investigate if door width can be fixed without replacing elevator 500 Big Thompson Ave 35 3/8"which is less than the 36"minimum.The gap between the floor and cab is 134" 508 which is over the 1'/."maximum tll Visitor Center- Entrances North side of Visitor The exterior entrance doors on the north side of the building close from 90-12'too 404.28 High 1 In Low Adjust door closers so doors close in no less than 5 seconds II1. 500 Big Thompson Ave Center quickly at 3.6 and 3.1 seconds which is under the 5 second minimum. IIII Erl 509 L Visitor Center- Entrances South side of Visitor The exterior entrance doors on the south side of the building close from 90-12°too 302.2,404.2.8 High 1 In Low Adjust closers so door close in no less than 5 seconds.Remove rug.(Rug was placed to reduce wear 1` - 500 Big Thompson Ave. Center quickly at 2.2 and 3.4 seconds which is under the 5 second minimum.There is also a on carpet by entrance,may need to either add an embedded entry slat mat like one in north vestibule - rug on the inside of the doors that is on carpet floor and is unsecured and or replace carpet in lobby area with carpet tiles that can be replaced when they wear out) -- - ----- carpeted 510 moves Visitor Center- Entrances South side of Visitor The doors to the afterhours area/public restrooms are not compliant The slope on the 302.2,404.2.4,404.2.8 High 1 Out and Medium Regrade the slope on the outside of the doors so it is less than 2%in any direction.Adjust closers so 500 Big Thompson Ave Center-Afterhours outside of the doors is 2.1%to 2 62%which is over the 2%maximum.The west door In door close in no less than 5 seconds.Remove rug.(Rug was placed to reduce wear on carpet by closes from 90-12°too quickly at 4.2 seconds which is less than the 5 second minimum. entrance,may need to either add an embedded entry slat mat like one in north vestibule or replace 511 There is a carpeted rug on the inside of the doors that is on carpet floor and is unsecured carpet in lobby area with carpet tiles that can be replaced when they wear out). and moves. _ Visitor Center- Entrances Visitor Center North The interior doors of the north entrance are not compliant.The east door has a slope in 302.2,404.2.4,404.2.8, High 1 Out and Medium Regrade the slope in the vestibule of the north entry so it is less than 2%in any direction.Adjust 500 Big Thompson Ave. Vestibule the vestibule of 2.27%which is over the 2%maximum.The west door closes from 90-12°404.2.9 In closers so door close in no less than 5 seconds and requires no more than 5 pounds of force to iir iftoo quickly at 3.7 seconds which is less than the 5 second minimum.The west door operate.Remove rug.(Rug was placed to reduce wear on carpet by entrance,may need to either iiC 512 requires 12.5 pounds of force and the east door requires 16.5 pounds of force which are add an embedded entry slat mat like one in north vestibule or replace carpet in lobby area with — both over the 5-pound maximum.There is a carpeted rug on the inside of the doors that carpet tiles that can be replaced when they wear out) is on carpet floor and is unsecured and moves. Visitor Center- Entrances Women's Public Restroom The entrance door for the women's restroom is not compliant.The maneuvering space 404.2.4,404.2.9 High 3 Out and High Reconfigure entrance so there is 12"minimum of maneuvering space on the latch side of the door. 500 Big Thompson Ave. on the push side of the door is inadequate at 4 Y."which is less than the 12"minimum. In Adjust door and/or closer so door requires no more than 5 pounds to operate. The door requires 5.5 pounds to operate which is more than the 5-pound maximum. 513 Visitor Center- Entrances Men's Public Restroom The entrance door for the men's restroom is not compliant.The maneuvering space on 404.24,404.2.8, High 3 Out and High Reconfigure entrance so there is 12"minimum of maneuvering space on the latch side of the door. 500 Big Thompson Ave the push side of the door is inadequate at 4"which is less than the 12"minimum The 404.29 In Adjust door and/or closer so door requires no more than 5 pounds to operate and closes in no less door requires 5.5 pounds to operate which is more than the 5-pound maximum.The than 5 seconds. - 514 door closes from 90-12°too quickly at 4.6 seconds which is less than the 5 second Visitor Center- Entrances Afterhours Area-Public The single door from the after-hours restroom area to the ambassador counter area is 404.2.3 Medium 2 Out Medium Adjust or replace door so there is a minimum of 80"of height clearance. 500 Big Thompson Ave. Restrooms not compliant with a height of 79'/."which is less than the 80"minimum. 515 Visitor Center- Water Fountains Afterhours Area-Public The right water fountain is not compliant.The spout height is 37%"which is less than the 602.4,602.6 Medium 3 Out and Medium Remount water fountain to Ada compliant height where the spout height is 38-43".Adjust spout 500 Big Thompson Ave Restrooms 38-43"height required.The water flow depth from the front edge is 6'/."which is over In angle so water flow is no more than 5"front the front edge the 5"maximum 516 Visitor Center- Restrooms Family Public Restroom The family restroom sink does not have ADA compliant knee clearance at 26%"which is 606.2 High 3 In or Medium Raise the sink 55"at least to have a minimum of 27"height for knee clearance. 500 Big Thompson Ave. less than the 27"minimum. Out 517 Visitor Center- Restrooms Women's Public Restroom The ADA stall in the women's restroom is not ADA compliant.The door is 5"from the 604.81.2 Medium 3 In Medium Adjust door opening so it is 4"maximum from the side wall.Modify door so it is self-closing Add 500 Big Thompson Ave side wall which is over the 4"maximum.The door is not self-closing and does not have ADA door pulls to both sides of the doors at an ADA compliant height. ' tg ADA door pull handles. 518 • Visitor Center- Restrooms Women's Public Restroom The ambulatory stall is not ADA compliant with a width of 39"which is over the 35-37" 604.8.2,604.8.1.2 High 3 In or High Remove first two stalls in the new section of the women's restrooms and replace with an ambulatory fj ----__ 500 Big Thompson Ave. requirement.The approach width to the ambulatory stall is 39"which is less than the 42" Out stall that is perpendicular to the other stalls.This will allow for a stall that is 60"deep minimum and 519 minimum.The door is not self-closing. 35-37"wide and has an adequate approach width. , / • Visitor Center- Restrooms Men's Public Restroom The men's restroom has 3 urinals and 3 toilets for a total of six fixtures.Six fixtures 213.31 High 3 N/A N/A The stalls are48"deep which is less than the 60"required for an ambulatory stall. -1I 500 Big Thompson Ave require an ambulatory stall which is currently not present. _ 520 Visitor Center- Restrooms Men's Public Restroom The men's restroom ADA stall is not ADA compliant.The door is 5"from the sidewall 604.8.1.2 Medium 3 In Medium Modify door so it is 4"maximum from the sidewall and is self-closing.Add ADA door pulls to both 500 Big Thompson Ave. which is over the 4"maximum.The door is not self-closing and does not have ADA door sides of the door. ' 521 pull handles. 43" Visitor Center- Restrooms Men's Public Restroom The right urinal is not ADA compliant with an outer face depth of 12%"from the rear 605.2 High 3 Out Medium Replace urinal with an ADA compliant one mounted at the same ADA compliant height _ 500 Big Thompson Ave support which is under the 13'h"minimum. _'*I f I — 522 • Visitor Center- Restrooms Men's Public Restroom The Men's restroom ADA stall does not have a compliant rear grab bar.The bar is 604.5 Low 3 In Medium Remount grab bar so there is 12"to the closed side and 24"to the open side. 500 Big Thompson Ave. mounted with 11"to the close side and 25"to the open side. idiom 523 Visitor Center- Restrooms Family Public Restroom The Family restroom ADA stall does not have a compliant rear grab bar.The bar is 609.4 Low 3 In Medium Remount grab bar so there is 12"to the closed side and 24"to the open side 500 Big Thompson Ave mounted with 11'h"to the close side and 24%"to the open side. 524 Visitor Center- Restrooms Women's Public Restroom The trash can in the Women's restroom ADA stall is mounted too far away at 17". 604.7 High 3 In Low Remount trashcan so it is 7-9"from the front of the toilet. — 500 Big Thompson Ave. 525 Visitor Center- Restrooms Women's Public Restroom The trash can in the Women's restroom Ambulatory stall is mounted too close at 8" 604.7 High 3 In Low Remount trashcan so it is 7-9"from the front of the toilet. 500 Big Thompson Ave before the front of the toilet which is outside of the 7-9"in front of the rim of the toilet. ` 526 i 3 Visitor Center- Restrooms Family Public Restroom The toilet paper dispenser in the Family restroom is mounted with outlets at 4"and 10" 604.7 Low 3 In Low Remount the toilet paper dispenser so one of the outlets is in the 7-9"range. 500 Big Thompson Ave. which is outside of the 7-9"requirement. 527 Transit Hub Shelter- Parking Lot North of Transit Hub There are 93 parking space in this parking lot section with 4 ADA parking spaces.None of 208.2,502.2 High 1 In or Medium Add a sign to all 4 ADA parking spaces with one space modified to be"Van Accessible".The van space an 1209 Manford Ave. Shelter the ADA parking spaces have a sign.None are marked or sized to be van accessible. Out needs to be 132"wide,should be able to restnpe an access aisle and ADA parking space into a van - - .. ADA parking space and narrower access aisle. 528 Transit Hub Shelter- Parking Lot North of Transit Hub The west ADA parking space is not compliant with a slope of 2.62%to 2.8%which is over 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. _MAI 1209 Manford Ave. Shelter the 2%maximum 529 Transit Hub Shelter- Parking Lot North of Transit Hub The middle west ADA parking space is not compliant with a slope of 2.1%to 3.67%which 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. 1209 Manford Ave. Shelter is over the 2%maximum. 530 WM Transit Hub Shelter- Parking Lot North of Transit Hub The middle east ADA parking space is not compliant with a slope of 2.27%to 3.32%which 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. _HIM 1209 Manford Ave. Shelter is over the 2%maximum. 531 Transit Hub Shelter- Parking Lot North of Transit Hub The east ADA parking space is not compliant with a slope of3.14%to 3.32%which is over 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. 0111111 1209 Manford Ave. Shelter the 2%maximum. 532 Transit Hub Shelter- Parking Lot North of Transit Hub The west ADA access aisle is not compliant with a slope of 2.1%to 3.84%which is over 502.4 High 1 Out High Regrade ADA access aisle so the slope is less than 2%in any direction. Milill 1209 Manford Ave. Shelter the 2%maximum 533 Transit Hub Shelter- Parking Lot North of Transit Hub The east ADA access aisle is not compliant with a slope of 2.1%to 3.84%which is over the 502.4 High 1 Out High Regrade ADA access aisle so the slope is less than 2%in any direction. 1209 Manford Ave. Shelter 2%maximum. 534 Transit Hub Shelter- Accessibl Route North of Transit Hub The sidewalk along the front of the ADA parking spaces is non-compliant with a cross 403.3 Medium 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5% t 1209 Manford Ave. Shelter slope of 2.1%in several spots which is over the 2%maximum. 535 Transit Hub Shelter- Accessibl Route North of Transit Hub The sidewalk to the east of the ADA parking spaces has a non-compliant cross slope of 403.3 Medium 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5%. 1209 Manford Ave. Shelter 2.44%which is over the 2%maximum. 536 Transit Hub Shelter- Accessibl Route Northeast of Transit Hub The top quarter of the sidewalk/ramp to the east of the ADA parking spaces with the 403.3,405 High 1 Out High Maximum cross slope is 2%.Continued in ramps section. 1209 Manford Ave. Shelter fence has a slope of 6.12%to 7.34%which makes this part of the sidewalk a ramp.The cross slope is 2.1%up to 3.32%mainly at the top of the sidewalk/ramp. 537 Transit Hub Shelter- Accessibl Route East of Transit Hub The sidewalk to the east of the top of the sidewalk/ramp has a non-compliant cross slope 403.3 Medium 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5%. __ 1209 Manford Ave. Shelter of2.62%which is over the 2%maximum. 538 Transit Hub Shelter- Accessibl Route South of Transit Hub The sidewalk to the east of the top of the sidewalk/ramp has a non-compliant cross slope 403.3 High 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5% 1209 Manford Ave. Shelter of2.62%which is over the 2%maximum.There is a section of the sidewalk where the slope increases to 5.6%which is over the 5%maximum. 539 - Transit Hub Shelter- Accessibl Route South of Transit Hub The sidewalk in front of the transit hub has a non-compliant cross slope of 2.44%which is 403.3 High 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5%. 1209 Manford Ave. Shelter over the 2%maximum. 540 Transit Hub Shelter- Accessibl Route West of Transit Hub The sidewalk along Manford Ave.west of the stairs has some spots where the cross slope 403.3 Low 1 Out High Regrade sidewalk so cross slope is less than 2%and running slope is no more than 5% 1209 Manford Ave. Shelter is up to 2.1%which is over the 2%maximum. 541 Transit Hub Shelter- Curb Ramps North of Transit Hub The west ADA curb ramp has a non-compliant vertical change.There is a chunk of 303.2 Medium 1 In or Low Refill broken out section or grand down edges at a 1:2 slope. 2IIIII 1209 Manfard Ave. Shelter crete broken out ofthe sidewalk surface bythe truncated domes that is%"in height Out which is over the Yr"maximum.542 - Transit Hub Shelter- Curb Ramps North of Transit Hub The east ADA curb ramp by the ADA parking space does not have a compliant landing 406.4 Medium 1 Out Medium Regrade landing so the slope is less than 2%in any direction 1209 Manford Ave. Shelter with a slope of 2.44%which is over the 2%maximum. 543 ; "��...,. -'..T Transit Hub Shelter- Curb Ramps North of Transit Hub The west sidewalk curb ramp is non-compliant with a slope of 16%at the front of the 405.2 Medium 1 Out Medium Regrade front of ramp so the slope is no more than 8.33%. \ - 1209 Manford Ave. Shelter ramp which is over the 8.33%maximum. - z. 544 .-...-.. Transit Hub Shelter- Ramps East of Transit Hub The top quarter of the sidewalk/ramp east of the ADA parking space and Transit hub has 405 High 1 Out High Can regrade ramp/sidewalk at top to reduce the slope below 5%and not need to regrade landings o s 1209 Manford Ave. Shelterr '`' -a slope steep enough that s a ramp.There are no handrails present.The top landing add handrails.If unable to,both landings need to be regraded to less than 2%in any direction.on Also, i�l• iYlN . has a non compliant cross slope of 4%wh ch is over the 2%maximum.The bottom will need to add ADA compliant handrails to both sides of the ramp 545 landing has a non-compliant slope of 4.37%which is over the 2%maximum - • Transit Hub Shelter- Signs Transit Hub Waiting Area The map sign on the wall ofthe transit hub is not compliant.The map is mounted at 72 703.4,703.5.5 Low 2 In Low Replace map with current transit shuttle map and lower the mounting height to 48"to 60". 1209 Manford Ave. Y."to 88"on the wall and has 3/16"to 3/8"text. . 546 i'- t - Transit Hub Shelter- Signs Transit Hub Waiting Area There is arestroom sign with arrow on the fence east of the transit hub.There is only 703 Low 3 In Low Remove sign if not providing restroom for the transit hub.Otherwise,will need to add wayfinding to , - r_.- ,,. Route from Transit hub to Event Center: 1209 Manford Ave. one sign and no other directions to get to a restroom. get from transit hub to restroom.All cross walks need to be stripped.Curb ramps for this route will also need to be checked for compliance. .q? 11 yr 547 Veteran's Monument Memorial Accessible Route Veteran's Monument The sidewalk through the Veteran's memorial monument has non-compliant cross slopes.403.3 Medium 1 Out High Regrade sidewalk so the cross slope is less than 2% 1 71 . -._ OP 4{s 1'. r" 4 ti`,i. 500 Big Thompson Ave The west entry sidewalk has a cross slope of21%.The east entry sidewalk has a cross S;f ---. ,, :. i slope of227%.There's a section by the Air Force sign where the cross slope s42%. 548 The maximum cross slope for an accessible routes 2%. Hydroplant Museum- Parking Lot ADA spaces North of The parking spaces for the Hydro plant museum area are not marked and the surface is 502.2,502.4,302.1 High 1 Out Medium Pave the parking surface so there is room for one van accessible ADA parking space along with one 1750 Fish Hatchery Road Hydroplane dirt/gravel. ADA access aisle.The slope must be less than 2%in any direction.Connect the access aisle to the -.."1111111111111111116'-�. sidewalk. -.-......- 549 _--_ Museum- Parking Lot Main Museum Lot The museum ADA parking space is notcompliant.There is no access aisle and the space is 502.2,502.3,502.4 High 1 Out High Regrade ADA parking space so the slope is no more than 2%in any direction.Restnpe the ADA 200 Fourth St. only 129%"wide which is less than the 192"minimum needed to have a van accessible parking space is a minimum 132"in width.Add an access aisle that is a minimum 60"in width.Add a T _. =,/- ` - spacewithaisle.The ADA space itself has a cross slope ranging from 3.14%to 5.6% curb ramp to the front ofthe access aisle so it is connected to the accessible route. a'... 550 which is over the 2%maximum.The space is not connected to the accessible route due .1 to the curb. .. Museum Annex- Parking Lot Museum Annex Lot There are seven ADA parking spaces in the Museum Annex parking spot and all of them 208.2,502.3,502.4 High 1 Out High Regrade a section of the parking lot that is closest to the Museum Annex for three ADA parking 220 Fourth St. are non-compliant due to slopes and cross slopes being over the maximum amount spaces and two ADA access aisles.The slope should be less than 2%in any direction.The access - allowed Only 3 ADA spaces are required for the parking lot with one being van aisles should be connected to the accessible route.If left where they currently are,a crosswalk will • �••':. _ 551 accessible.There are no compliant access aisles,and none of the ADA parking spots or need to be striped and regraded so the cross slope is no more than 2%and slope no more than 5%. aisles are connected to the accessible route. Hydroplant Museum- Accessible Route Sidewalks-Hydroplant The bridge by the Hydro plant museum has a non-compliant gap on the north side of the 302.3 High 2 In or Medium Fill in gap so the space between the sidewalk and the bridge is less than%".The maximum vertical - 1750 Fish Hatchery Road bridge.There is a 3/8"to US"gap between the sidewalk edge and the bridge. Out change allowed at the bridge end is 14". .. Additionally,the sidewalk end is beveled towards the gap increasing the severity.552 t -- Hydroplant Museum- Accessible Route Sidewalks-Hydroplant The sidewalk between the Hydro plant museum and the bridge has a couple sections with 303.2 Medium 2 In or Medium Grind the vertical change so it is less than'/."or regrade that section so there is no vertical change r.•- -- 1750 Fish Hatchery Road a non-compliant vertical change.There is a''/."and a'h"vertical change along this Out over'/". sidewalk section. 553 - Yw Hydroplant Museum- Accessible Route Sidewalks-Hydroplant The sidewalk between the bridge and the Hydro plant museum is not ADA compliant.The403.3,405 High 2 Out High Regrade this section of the sidewalk.Option one is to reduce the slope of the sidewalk by leveling out - 1750 Fish Hatchery Road slope ofthe sidewalk ranges from 5.6%to 12.46%and the cross-slope ranges from 1.9% the sidewalk elevation so the running slope is no more than 5%and the cross-slope is less than the 2'. " to 2.44%which is over the 2%maximum.The slope of the sidewalk makes it a ramp and maximum.Option 2 is to create landings on both sides of the sidewalk that have a slope less than 2% {",�: 554 there are no compliant handrails or landings for the ramp. in any direction,then add ADA compliant handrails to both sides of the ramp. ` -k' J Hydroplant Museum- Accessible Route Sidewalks-Hydroplant The bridge from the Hydro plant museum to O'Connor Pavilion is not ADA compliant. 403.3,405 Medium 2 Out High Regrade the sidewalk on the north side so there is a landing that is 60"long and the slope is less than _:p 1750 Fish Hatchery Road The slope of the bridge is up to 5.77%which makes it a ramp.There is no ADA compliant the 2%maximum.Add ADA compliant handrails to both sides of the bridge.Add curb barriers to - - landing on the north side of the bridge.The bridge does not have handrails. both sides of the bridge 555 11III: - 1' Hydroplant Museum Accessible Route Sidewalks-Hydroplant The sidewalk from the Hydro plant if to the museum is not ADA compliant.The slope 403.3,405 High 1 Out High Redo the sidewalk so the running slopes less 5%and cross slopes less than 2%.May need to Chang: ''S 1750 Fish Hatchery Road of the sidewalk ranges from 5.42%to 11.92%wh ch is over the 5%max mum and makes the route,otherwise will have to treat as a ramp and add level landings and handrails. 1_t /• it a ramp.The cross slope of the sidewalk is up to 3.84%which is over the 2%maximum. '7' - 3`+.r 556 r • iiiiiArt Hydroplant Museum- Accessible Route Sidewalks-Hydroplant The display/information structure next to the hydro museum office has non-compliant 403.3 Medium 2 Out High Regrade the sidewalk and entry so the cross-slope is less than the 2%maximum. n,w u, 1750 Fish Hatchery Road cross-slopes of 244%and the entry cross slope is 5.24%which are over the 2% - - A 557 maximum. - - ,. • i , Hydroplant Museum Accessible Route Sidewalks-Hydroplant The sidewalk from the Hydro plant museum office to the nearby parking lot is not ADA 403.3,405 High 1 Out High Regrade the sidewalk so the running slope is less than 5%and the cross slopes less than 2%. • 1750 Fish Hatchery Road compliant. ompl ant The slope of the sidewalk has a range that is up to 8.22%to 9.28%which is Otherwise,this s a ramp and needs to have level landings and ADA compliant handrails added. ver the 5%maximum making this section a ramp.The cross-slope of the sidewalk near - =Cy. 558 the fork is up to 3.67%which sower the 2%maximum. -• 'Museum- Accessible Route Sidewalks-Museum The sidewalk between the Museum Annex and the Museums not ADA compliant.The 403.3,405 High 1 Out High Reconfigure this section of sidewalk so the running slopes less than 5%and the cross slopes less ,- .._ - • _ 200 Fourth St. slope of the sidewalk reaches ranges from 7%to 12.1%which is over the 5%maximum than 2%.Otherwise need to add level landings with ADA compliant handrails and treat this section as -- " - v '1 i *_ I and makes this section a ramp.The cross slope is up to 8.4%which is over the 2% a ramp. -- 559 maximum. r- Museum- Accessible Route Sidewalks-Museum The sidewalk between the Museum office entrance and the main entrance is not 403.3 Medium 2 Out Medium Regrade sidewalk so the cross-slope is less than the 2%maximum. 200 Fourth St. compliant.The cross-slope ranges from 2.44%to 2.97%which is over the 2%maximum. 560 1111 Museum- Accessible Route Sidewalks-Museum The sidewalk at the main entrance has a slope that is up to 5.07%which makes part of 403.3,405 Medium 1 Out Medium Regrade sidewalk by front entry so the slope is less than 5%and cross slope less than 2%. 200 Fourth St. this section a ramp. 561 Museum- Accessible Route Sidewalks-Museum The sidewalk outside the Museum rear door is not ADA compliant.The sidewalk has a 403.3 High 1 Out Medium Redo sidewalk so the cross-slope is less than the 2%maximum. 200 Fourth St. cross-slope that ranges from 2 1%to 4%which is over the 2%maximum 562 Museum- Accessible Route Sidewalks-Museum The section of sidewalk that angles down toward the Joel Estes statue is not ADA 403.3,405 High 1 Out High Regrade/Reconfigure the sidewalks between the rear of the Museum and the Cobb-Macdonald cabin 200 Fourth St. compliant.The slope of the sidewalk ranges from 4%to 6.82%which makes it a ramp. and Boyd building so the running slopes are less than 5%and the cross-slopes are less than 2%.Any running slope over 5%is considered a ramp and needs level landings on both sides as well as ADA 563 compliant handrails on both sides. Museum- Accessible Route Sidewalks-Museum The sidewalk on the south side of the Joel Estes statue is not ADA compliant The running 403.3,405 High 1 Out High Regrade/Reconfigure the sidewalks between the rear of the Museum and the Cobb-Macdonald cabin 200 Fourth St. slope ranges from 5.42%to 5.94%which is over the 5%maximum and makes this section and Boyd building so the running slopes are less than 5%and the cross-slopes are less than 2%Any a ramp. running slope over 5%is considered a ramp and needs level landings on both sides as well as ADA 564 compliant handrails on both sides. Museum- Accessible Route Sidewalks-Museum The section of sidewalk on the west side of the Joel Estes statue is not ADA compliant. 403.3 Medium 1 Out Medium Regrade this section so the cross-slope is less than the 2%maximum. 200 Fourth St. The cross-slope is up to 3.84%which is over the 2%maximum. 565 Museum- Accessible Route Sidewalks-Museum The sidewalk on the northeast side of the Joel Estes statue is not ADA compliant.The 403.3,405 High 1 Out High Regrade/Reconfigure the sidewalks between the rear of the Museum and the Cobb-Macdonald cabin 200 Fourth St. running slope ranges from 11.4%to 12.63%which is over the 5%maximum and makes and Boyd building so the running slopes are less than 5%and the cross-slopes are less than 2%Any this section a ramp. running slope over 5%is considered a ramp and needs level landings on both sides as well as ADA 566 compliant handrails on both sides. , Museum- Accessible Route Sidewalks-Museum The sidewalk by the west entry of the Cobb-Macdonald cabin has a slope of 6.82%which 403.3,405 High 2 Out Medium Regrade/raise sidewalk so the slope is less than 5%and cross slope is less than 2%with the sections -- 200 Fourth St. is over the 5%maximum and makes this section a ramp. near the entrances close to level with the thresholds of the entry doors. 567 ____ Museum- Accessible Route Sidewalks-Museum The sidewalk on the north side of the Boyd building is not ADA compliant.The running 403.3,405 High 1 Out High Regrade/Reconfigure the sidewalks between the rear of the Museum and the Cobb-Macdonald cabin ,• 200 Fourth St. slope ranges from 7.52%to 9.28%which makes this section a ramp.The cross-slope and Boyd building so the running slopes are less than 5%and the cross-slopes are less than 2%Any - ranges from 2.97%to 4%which is over the 2%maximum. running slope over 5%is considered a ramp and needs level landings on both sides as well as ADA 568 compliant handrails on both sides. - Museum Annex- Ramps Main Entrance The ramp by the Museum Annex entrance is not ADA compliant.The bottom of the ramp 405.3,405.7,405.8 High 1 Out High Regrade bottom of ramp and ramp landing so the cross slope is less than the 2%maximum and the - '} " s 220 Fourth St. has a cross slope of 3.32%which is over the 2%maximum.The handrails do not extend landing has a slope less than 2%in any direction.The handrails need to be extended a minimum of 7IIf1 '- r ' beyond the ramp bottom and are 2-5"short of the landing which is less than the 12" 12"beyond the top and bottom of the ramp.There should be a minimum of 1'h"between the :Al. I--/�_._ r�11":7' ' minimum beyond the ramp bottom.The handrails extend 5"and 9"beyond the top of handrail and adjacent surface. 1 - " -569 the amp wh ch s less than the 12"m n mum beyond the ramp end.The rght handra l at I }i�� "'�^ Z the top of the ramp has a 1"gap between the handrail and the wall which is less than the x " 1%"minimum gap required.The bottom ramp landing has a cross slope of 4.2%which is f 1.ii_ over the 2%maximum. Hydroplant Museum- Stains By Hydroplant The stairs by the Hydro plant museum are not ADA compliant.The tread depths are not 504.2,505 High 2 Out High Redo stairs so the tread depths and riser heights are uniform.Add ADA compliant handrails to both 1750 Fish Hatchery Road uniform and range from 12"to 13"in depth.There are no handrails present. sides of the stairs. 570 Museum Annex- Stairs Main Entrance The main entry stairs for the Museum Annex are not ADA compliant The riser heights 504.2,505.5 High 1 Out High Redo stairs so the tread depths and riser heights are uniform.There should be a minimum 1 JJ"gap ,Rt '! !10 220 Fourth St. not uniform and range from 4%"to6".The tread depths are not uniform and range between the handrail and adjacent surfaces. - from 10'A"to 11" The right handrails have a 11/8"gap between the handrail and y;. 571 adjacent surface which is less than the 1%"minimum. r Hydroplant Museum- Entrances Hydroplant Office The entrance door to the Hydro Plant Museum Office is not ADA compliant.The slope on 302.2,404.2.4,404.2.5, High 1 In and High The slope on both sides of the door needs to be less than the 2%maximum.Move the table on the -Jr 1750 Fish Hatchery Road the inside of the door is 2.27%and on the outside is 3.32%which are over the 2% 404.2.10,404.2.11 Out inside,pull side,ofthe door so there is a minimum of 18"between the door and the table.Themaximu p�■ I. The maneuvering width on the inside,pull side,of the door is 13"due to a threshold needs to be replaced with one that has a maximum height of%"with the top IS"beveled 4! k table which is less than the 18"minimum.The threshold for the entry door is 13/8"in 1:2.Add a 10"kickplate to the bottom of the push side of the door.The bottom edge of the window , .. 572 height which is over the%"maximum allowed.There is no kickplate present,and the in the door should be 43"maximum(Replace the door?Is it considered historic and is protected?). I door is flat for 8%"which is less than the 10"minimum.The door has a glass window Secure the edges of the rug to the floor. with a bottom height of 56 5/8"which is over the 40"maximum.There is a carpeted rug with rubber edges that is not attached to the ground. Hydroplant Museum- Entrances Hydroplant Office The Hydro Plant Museum office ADA restroom door is not ADA compliant.The door has 404.2.3,404.2.4, High 3 In Medium Replace the threshold with a beveled one that is%"in height which will fix the threshold issue along 1750 Fish Hatchery Road a height of 79%"which is less than the 80"minimum.The threshold is stepped instead of 404.2.5,404.2.8, with the door height issue.Adjust the door closer so the door closes from 90°to 12°in no less than 5 I ' 4t I4 beveled.The door closes from 90°to 12°in 3.2 seconds which is less than the 5 second 404.2.10 seconds.Add a 10"high kickplate on the door.Move the heater toward the non-ADA restroom door l -/ 573 minimum.The pull side of the door has 8"of maneuvering width which is less than the to create a minimum of 18"of maneuvering width. 18minimum.There is no kickplate on the door and the flat door surface is 8'h"high which is less than the 10"minimum. Hydroplant Museum- Entrances Hydroplant Museum The entrance door to the Hydro Plant Museum is not ADA compliant.The slope on the 302.2,404.2.4, Medium 2 Out Medium The entrance door to the Hydro Plant Museum is not ADA compliant.The slope on the outside of the W. b .. 1750 Fish Hatchery Road outside of the door ranges from 2.8%to3.84%which are over the 2%maximum.The 404.2.11 door ranges from 2.8%to 3.84%which are over the 2%maximum.The door has a glass window with' �,I'.l■ door has a glass window with a bottom height of 52 3/8"which is over the 40"maximum. a bottom height of 52 3/8"which is over the 40"maximum.There is a carpeted rug with rubber ■ - 574 There is a carpeted rug with rubber edges that is not attached to the ground. edges that is not attached to the ground. Museum- Entrances Cobb-Macdonald Cabin The south door of the Cobb-Macdonald is not ADA compliant.The height of the door is 404.23,404.2.3, High 2 In and Medium The door minimums for ADA compliance are 80"in height and 32"in width.Regrade the outside of Pill Fourth St. 74'A"and the width is 28"which are both less than the minimums allowed.The slope on 404.2 4,404.2.7, Out the door so the slope is less than the 2%maximum.Add a 10"high kickplate on the door.Add a the outside of the door is 21%which is over the 2%maximum.There is no kickplate on 404.210 lever type door handle or other type of ADA compliant handle to the door. 575 the door and the flat door surface is 3%"high which is less than the 10"minimum The I door knob is round and requires grasping which is not compliant Museum- Entrances Cobb-Macdonald Cabin The west door of the Cobb-Macdonald is not ADA compliant.The height of the door is 76 404.2 3,404.2.3, High 2 In and Medium The door minimums for ADA compliance are 80"in height and 32"in width.Regrade the inside and 200 Fourth St. 3/8"and the width is 27%"which are both less than the minimums allowed.The slope 404.24,404.2.5, Out outside of the door so the slope is less than the 2%maximum.Replace the threshold of the door with on the outside of the door is 4.72%which is over the 2%maximum.The slope on the 404.27,404.2.10 an ADA compliant one that is less than theft"maximum with the top A"beveled 1:2.Add a 10"high inside of the door is 2.62%which is over the 2%maximum The threshold of the door is kickplate on the door.Add a lever type door handle or other type of ADA compliant handle to the 576 3"in height which is over theft"maximum.There is no kickplate on the door and the flat door.Reconfigure area so door can have 60"of maneuvering depth on the pull side. ,_ door surface is 8"high which is less than the 10"minimum.The door knob is round and requires grasping which is not compliant.The door has 35%"of maneuvering depth on the pull side which is less than the 60"minimum. Museum- Entrances Boyd Building The entrance door to the Boyd building is 27 3/8"wide which is less than the 32" 302.2,404.2.3,404.2.4, Medium 2 In and High The door minimums for ADA compliance are 80"in height and 32"in width.Regrade the outside of 200 Fourth St. minimum.The slope on the outside of the door is 2.44%which is over the 2%maximum. 404.25 Out the door so the slope is less than the 2%maximum.Secure the edges of the rug to the floor. I II The threshold of the door is 1"in height which is over the%"maximum.There is aIIM I.1.MC j 577 carpeted rug with rubber edges that is not attached to the ground "j— — Museum- Entrances Main Entry The front entrance doors to the Museum are not ADA compliant.The slope on the 302.2,404.2.4,404.2.8, High 1 In and Medium Regrade the outside of the doors so the slope is less than the 2%maximum.Adjust the door closers 200 Fourth St. outside of the doors is 4.2%and the cross-slope is 3.14%which are over the 2% 404.2.10 Out so the door closes from 90°to 12°in no less than 5 seconds.Add a 10"kickplate to the doors.Secure -� --' maximum.The doors close from 90°to 12°in 4.2 and 2.5 seconds which is less than the 5 the edges of the rug to the floor. 578 seconds minimum.Both doors do not have a kickplate and only 47/8"of flat door — - surface from the floor.There is a carpeted rug with rubber edges that is not attached toii.fa the ground. Museum- Entrances Main Entry The interior doors of the Museum front entrance are not ADA compliant.The left door 302.2,404.2.3,404.2.8, Medium 2 In Medium Adjust the door closers so the door closes from 90°to 12°in no less than 5 seconds and require no 200 Fourth St. closer has a height of 77%"which is less than the 78"minimum.The right door closes 404.29,404.2.10 more than 5 pounds of force.Add a10"kickplate to the doors.Secure the edges of the rug to the >d•° 0 ONG from 90°to 12°in 2.9 seconds which is less than the 5 seconds minimum.The doors floor. �e • NU -�j J 579 require 10 pounds and 13 pounds of force to operate which is more than the 5-pound El l maximum.Both doors do not have a kickplate and only 8"of flat door surface from the floor.There is a carpeted rug with rubber edges that is not attached to the ground. Mr Museum- Entrances Rear The Museum rear door is not ADA compliant.The slope on the outside of the door is 404.2.4,404.2.7 Medium 2 In and Medium Remove the two handles and replace with one ADA compliant handle that is mounted between 34" 200 Fourth St. 2.62%which is over the 2%maximum.The handles on the outside are at heights of 29% Out and 48".The door does have an ADA opener device.Regrade the onside of the door so the slope is DIM ii 580 34%"and 48%"-54"which are mostly outside of the 34"-48"compliant range. less than 2%in any direction. Museum- Entrances Rear The rear door of the Museum conference room is not ADA compliant.The height of the 302.2,404.2.3,404.2.8 High 2 In and High The door minimums for ADA compliance are 80"in height and 32"in width.The closer height is 200 Fourth St. doorway is 79%"with the closer height 76%"which are less than the 80"and 78" Out allowed to be a minimum of 78".Adjust the door closer so the door closes from 90°to 12°in no less minimums.The door closes from 90'to 12'in 1.5 seconds which is less than the 5 second than 5 seconds.Secure the edges of the rug to the floor. 581 minimum.There is a carpeted rug with rubber edges that is not attached to the ground. 1 ii Museum- Entrances Interior The door to the Museum women's restroom is not ADA compliant.The door is recessed 404.2.4,404.2.8, High 3 In and Medium Add an ADA button to the door.Add a 10"kickplate to the door. C ' 200 Fourth St. 3015"and has 8 35"of maneuvering width on the push side of the door which is less than 404.2.9,404.2.10 Out the 12"minimum.The door closes too quickly from 90°to 12°in 3.4 seconds which is 582 less than the 5 second minimum.The door requires 11 pounds of force to operate which -- is less than the 5-pound maximum.There is no kickplate and the door surface is flat for only 8"from the floor. Museum- Entrances Interior The door to the Museum men's restroom is not ADA compliant.The door is recessed 30 404.2 4,404.2.8, High 3 In and Medium Add an ADA button to the door.Add a 10"kickplate to the door. 200 Fourth St. 1/8"and has 8%"of maneuvering width on the push side of the door which is less than 404.29,404.2.10 Out ' the 12"minimum.The door closes too quickly from 90°to 12°in 4 seconds which is less I 583 than the 5 second minimum.The door requires 8 pounds of force to operate which is less than the 5-pound maximum.There is no kickplate and the door surface is flat for only 8" front the floor. Museum- Entrances Interior The Museum conference room door closes too quickly from 90°to12°in 3.3 seconds 404.2.4,404.2.8, Medium 2 In Low Adjust the door closers so the doors close from 90°to 12°in no less than 5 seconds.Add a 10" • fir'''' 200 Fourth St. which is less than the 5 second minimum.There is no kickplate and the door surface is 404.2.10 kickplate to the door.Move the display to the hinge side of the door or elsewhere so there is a 18" flat for only 8"from the floor.The maneuvering clearance for the pull side of the door is wide by 60"deep maneuvering space on the pull side of the door. %•r 584 blocked by the tree cut rings display. I Museum Annex- Entrances Main Entry The Museum Annex entrance doors close too quickly from 90°to 12°in 3 seconds and 3.5302.2,404.2.8 Medium 2 In Medium Adjust the door closers so the doors close from 90°to 12°in no less than 5 seconds.Secure the edges I 1 220 Fourth St. seconds which is less than the 5 second minimum.There is a carpeted rug with rubber of the rug to the floor. _ ! ` edges that is not attached to the ground ' 585 113 IP Museum Annex- Entrances Main Entry The interior doors of the Museum Annex main entrance are not ADA compliant.The 404.2.8,404.2.9 Low 2 In Low Adjust the door closers so the doors close from 90°to 12°in no less than 5 seconds and require no 220 Fourth St. doors close from 90°to 12°in 4 seconds and 4.3 seconds which is less than the 5 second more than 5 pounds of force to operate.The right door does have an ADA opener and needs to be tf. minimum.The required force to operate the doors is 10 pounds and 9 pounds which are turned on when building is open to the public. 586 over the 5-pound maximum. Museum Annex- Entrances Interior The door to the Museum Annex Reference Room has a non-ADA compliant door height at 404.23 Medium 2 In Medium Modify door frame so the height is a minimum of 80" 220 Fourth St. 79%"which is less than the 80"minimum. N — _ P1 587 ,Museum Annex- Entrances Interior The Museum Annex restroom door is not ADA compliant.The door closes from 70°to12°404.2.4,404.2.8, Medium 3 In Medium Move the"Step-N-Pull"to the proper place being mounted on the inside surface of the door.Adjust - , r. 220 Fourth St. in 3.75 seconds which is less than the 5 second minimum.The door requires 7 pounds of 404.2.9 the door closer so the door close from 90°to12°in no less than 5 seconds and require no morethan or A force to operate which is over the 5-pound maximum.There is a"Step-N-Pull"mounted 5 pounds of farce to operate. V',- t 588 underneath the door which causes the door to stick open when at 90°. Hydroplant Museum- Accessible Pathway Hydroplant Museum The accessible pathway in the Hydro Plant Museum is not ADA compliant There are 403.3 High 2 Out High Regrade and/or add a floor surface to the Hydro Plant Museum so there is a pathway that is 36"wide t a 1750 Fish Hatchery Road s where the slope reaches up to 14.77%and the cross-slope is up to 4 2%which are and has a running slope less than 5%and cross-slope less than 2%. V - 589 over the 5%and 2%maximums Hydroplant Museum- Accessible Pathway Hydroplant Museum There are several protrusions around the accessible pathway of the Hydro Plant Museum.307 High 2 In or Medium Add a shield to these areas from the ground to the leading edge of the protrusions. 4 p w „.---_. 1750 Fish Hatchery Road The Hug wheel has a wheel crank with a 35 3/8"leading edge and a 6-7"protrusion.The Out back of the Worthington wheel has an 8"protrusion with a 33"leading edge height.The f - I 590 rear of the hug wheel has an 8"protrusion with a 37"leading edge.The rear room has wood display plaques mounted on the wall that have a 9%"protrusion with a 42%"to 43"leading edge. Museum- Accessible Pathway Cobb-Macdonald Cabin The south side of the Cobb-Macdonald cabin has a pathway that is 48"wide.There is no 403.53 High 2 In High Reconfigure so that there is a 60"wide pathway. 200 Fourth St. passing space provided and is required since access route is less than 60"wide. 591 - 1 1 5 q I Museum- Accessible Pathway Cobb-Macdonald Cabin The west side of the Cobb-Macdonald cabin has a pathway that is 51"wide and 35%" 304.3,403.3 High 2 In and High Reconfigure so that there is a 60"diameter turnaround space.Regrade the slope of the floor so it is ' 200 Fourth St. deep with no turnaround space provided.The slope of the area is 2.62%and at the Out less than 2%in any direction. . doorway entrance. 592 Museum- Accessible Pathway Interior The retail area of the Museum is not ADA compliant.There is a table in the middle of the 403.5 High 2 In Medium Rearrange retail shop so there is a 36"wide minimum pathway around the retail area. L 4, . 200 Fourth St. area that reduces the accessible pathway to 22"to 32"which is less than the 36" _ _ . minimum. i. .eJ 593 Museum- Accessible Pathway Interior The Museum Gallery has a tree by the"Stories under the stars"exhibit that leans into the 307 Medium 2 In Medium Add a shield around the base of the protrusion that is 27"minimum in height from the floor,or adjust y 200 Fourth St. accessible pathway.The leading edge is 57"and the protrusion extends up to 12"into tree so it does not protrude into accessible pathway. "t- ]-, the pathway. s; 594 Museum- Accessible Pathway Interior The Museum Gallery has display boxes mounted on the walls of the Stanley Steamer area 307 Medium 2 In Medium Add a shield that reduces the leading edge to a maximum of 27"or from the floor up a minimum of i 200 Fourth St. that are not ADA compliant.The displays protrude 9 Y."to93/8"into the accessible 27" 595 pathway and have a leading edge of 35 3/8"in height. W. Hydroplane Museum- Stairs Hydroplane Museum The Hydro Plant Museum has single steps into the Worthington Wheel area that are not 505 High 2 Out High Add a second step with a height 4-7"and make riser heights uniform.Add ADA compliant handrails \ - Ir + `Z -y.�t 1750 Fish Hatchery Road ADA compliant with missing handrails.The riser heights are not compliant at 11"and 11 to both sides of the stairs. - %"which is over the 7"maximum. 596 Hydroplant Museum- Signs Hydroplant Office The sign for the Hydro Plant Museum office is not ADA compliant.There is only 8"of 703.4,703.6 Medium 3 In Medium Move heater and replace sign with an ADA compliant one. 1750 Fish Hatchery Road clear floor space which is less than the 18"minimum.The pictogram has a height of 3 3/8"which is less than the 6"minimum. 597 Hydroplant Museum- Signs Hydroplant Office The Open/Closed sign for the Hydro Plant Museum office is not Ada compliant.The sign 703.2,703.3,703.4 Low 2 In Low Replace with an ADA compliant sign that is mounter with the text baseline 48"to 60"in height. 1750 Fish Hatchery Road does not have raised letters or braille and is mounted at a height of 63 5/8". 598 Museum- Signs Interior The Museum Annex restroom sign is not ADA compliant.The sign is mount on the push 703.4 Medium 3 In Low Move the sign to the latch side of the door with the text baseline mounted 48"to 60"in height. 200 Fourth St. side of the door. 599 Museum- Signs Interior The signs for the Museum women's restroom are not compliant.The signs have a 703.4,703.6 Low 3 In Low Remove sign that is on the door and replace the sign on the wall with an ADA compliant one. 200 Fourth St. pictogram height of 4"which is less than the 6"minimum.One sign is mounted on the 600 push side of the door with a text baseline of 60 5/8". 't I Museum- Signs Interior The signs for the Museum men's restroom are not compliant.The signs have a pictogram 703.4,703.6 Low 3 In Low Remove sign that is on the door and replace the sign on the wall with an ADA compliant one. 200 Fourth St. height of 4"which is less than the 6"minimum.One sign is mounted on the push side of the door with a text baseline of 60 5/8". 601 Museum- Signs Interior The sign for the Museum conference room is not ADA compliant with no raised letters or 703.2,703.3,703.4 Medium 2 In Low Replace with an ADA compliant sign on the latch side of the door. 200 Fourth St. braille and being made of printer paper mounted on the pull side of the door. 5. 602 Museum- Controls Interior The screen toggles for the Museum conference room are not ADA compliant being 308.1 Medium 4 In or Medium Remount switches so they are a maximum of 48"in height. 200 Fourth St. mounted at a height of 49%" Out el 603 Museum- Controls Interior The"Stones under the stars"exhibit has buttons to activate stories that have a height of 308.1,403.3 Medium 4 In Medium Raise the button so they are a minimum of 15"in height and rearrange the stumps so there is a 36" _ 200 Fourth St. 3 X"to 7%"which is less than the 15"minimum.The stumps for seating are 29"which is entrance to the buttons. less than the 36"accessible pathway needed. 604 Museum- Controls Main Entry The button for the front entrance ADA door does not have a compliant clear floor space 404.35 High 2 Out Medium Regrade clear floor space so the slope is less than 2%in any direction - 200 Fourth St. with a slope of 2.1%which is over the 2%maximum. 605 Museum- Controls Rear Entry The button for the rear entrance ADA door does not have a compliant clear floor space 404.3.5 High 2 Out Medium Regrade clear floor space so the slope is less than 2%in any direction. 200 Fourth St. with a slope of 2.44%which is over the 2%maximum. 606 Museum- Seating Areas Interior The Museum gallery has two sitting areas to view information videos.The first is by the 802 High 2 In Medium Reconfigure both seating areas so the is one area with a 36"wide by 48"deep clear space for a '' l 200 Fourth St. gallery entrance and the second is the Park Theatre exhibit.Neither area has wheelchair forward approach or a 36"wide by 60"deep clear space for s side approach. i - 607 space for ADA seating. - 4111.4110 Hydroplant Museum- Seating Areas Hydroplant Office The Museum Hydro Plant area has a picnic bench and table but no ADA seating available.902.2 High 4 In and Medium Replace picnic table with one that has ADA seating.Regrade picnic area surface so the slope is less 1750 Fish Hatchery Road The slope of the area is 6%and the cross slope is 2.44%which are over the 2%maximum. Out than 2%in any direction. -1t- ' 4,4 608 Hydroplant Museum- Retail Counters Hydroplant Office The counter for the Museum hydro Plant office is not ADA compliant.There is no 904,305.2 High 2 In and Medium Add a cut out that is 36"wide and 27"in height and is a minimum of 17"under the counter which is INI 1750 Fish Hatchery Road compliant knee clearance with only 1"of depth under heath the counter.The cross slope Out 24".Adjust the flooring area so the cross slope is less than 2%. for the counter area is 2.79%which is over the 2%maximum. 609 Museum- Retail Counters Interior The main counter of the Museum does not have compliant ADA knee clearance There is 904,306.2,306.3 High 2 In Medium Replace counter with one that has ADA compliant knee clearance that is 36"wide,27"in height,and %-:. `V 200 Fourth St. 2"of knee depth under the counter which is less than the 17"minimum 17"in depth minimum ' 610 Museum- Retail Counters Interior The counter in the retail shop of the Museum is not ADA compliant.There is 1%"—2"of 904,306.3 High 2 In Medium Replace counter with one that has ADA compliant knee clearance that is 36"wide,27"in height,and - f"• 200 Fourth St. knee depth under the counter which is less than the 17"minimum.The counter is split 17"in depth minimum. into two heights that are 28 Y."and 23"wide which is less than the 36"minimum. 611 Museum- Service Counters Interior The kitchenette counter in the Museum conference room is not Ada compliant.The 904,306.3 Medium N/A N/A N/A This is not a non-compliance issue since the counter is not a retail one but should be noted.It would 200 Fourth St. counter has a top height of 36%"which is over the 36"maximum.The knee depth under not be compliant as a serving area due to the counter height being 36%"which is over the 34" the counter is 12'A"which is less than the 17". maximum. 612 Museum- Coat Hooks and Shelves Interior The coat hooks and shelves in the Museum main lobby are not compliant.The ADA shelf 225.2.2 High 2 In Low Move the pamphlet holder to another location so the shelf is accessible. h 200 Fourth St. is blocked by a pamphlet holder. i111.=-tlik M' 613 Museum- Water Fountains Interior There is only one water fountain and not the required two with one wheelchair and one 602.7,602.2 High 3 Out High Remount current water fountain so knee height is 27"minimum and is compliant for a wheelchair. 200 Fourth St. standing.The water fountain has 25%"of knee height which is less than the 27" Add a standing water fountain next to this one.Move tree ring cut display. minimum.The is only 2%"width between water fountain and tree ring cut display 614 Hydroplant Museum- Restrooms ADA Restroom The Hydro plant museum office ADA restroom is not ADA compliant.The distance 604.3.2 High 3 Out High Remount the sink so there is a 60"wide clear floor space around the toilet. 1750 Fish Hatchery Road between the side wall and the sink is 39%"which is less than the 60"minimum required for the toilet clear floor space. 615 Hydroplant Museum- Restrooms ADA Restroom The Hydro plant museum office ADA restroom does not have a compliant knee height for 606.2 High 3 In or Medium Raise counter so the knee height is a minimum of 27". 1750 Fish Hatchery Road the counter.The bottom of the sink basin has a height of 26"which is less than the 27" Out 616 minimum. Museum Annex- Restrooms Main Restroom The Museum Annex public restroom does not have a compliant knee height for the 606.2 High 3 In or Medium Raise counter so the knee height is a minimum of 27". 220 Fourth St. counter and sinks.The bottom of the sink basin has a height of 26"which is less than the Out 27"minimum. 617 Museum Annex- Restrooms Main Restroom The Museum Annex public restroom ADA stall has a pull handle on the inside of the door 604.81.2 Low 3 In Low Add a pull handle on the outside of the ADA stall door.Adjust hinges so door self-closes the entire 220 Fourth St. only.The door self closes 90%but not all the way. way. 618 Museum Annex- Restrooms Main Restroom The Museum Annex public restroom ADA stall toilet has the control on the closed side. 604.6 High 3 In Medium Replace toilet so the controls are on the open(right(side. 220 Fourth St. 619 Museum Annex- Restrooms Main Restroom The Museum Annex public restroom ADA stall grab bars are not compliant The rear grab 604.5 High 3 In Medium Remount both grab bar so the rear grab bar has a maximum height of 36"and the side grab bar is 12" 220 Fourth St. bar has a height of 36'A"which is over the 36"maximum.The side grab bar is 47%" from the rear wall and 54"minimum. from the rear wall with a 5%"gap which is less than the 54"minimum with a 12" 620 maximu m gap. Museum Annex- Restrooms Main Restroom The Museum Annex public restroom mirror is not ADA compliant.The bottom reflective 603.3 High 3 In Medium Remount the mirror so the bottom reflective surface is no higher than 40". T J 0 220 Fourth St. edge of the mirror is 49 3/8"which is over the 40"maximum. 621 ,_.„ Museum- Restrooms Women's The Museum public women's restroom does not have a compliant knee height for the 606.2 High 3 In or Medium Raise counter so the knee height is a minimum of 27". _ 200 Fourth St. counter and sinks.The bottom of the sink basin has a height of 25%"which is less than Out the 27"minimum. 622 Museum- Restrooms Women's The ADA stall in the Museum public women's restroom is not ADA compliant.The door is 604.8.1.2 High 3 In and High Adjust stall door so it is no more than 4"from the side wall.Adjust or replace hinges so door self- 200 Fourth St. 4%"from the side wall which is more than the 4"maximum.The door is not self-closing Out closes completely.Add pull handles to both sides of the door. . and only closes Y."of the way.There are no pull handles. 623 Museum- Restrooms Women's The Museum public women's restroom ADA stall has a non-compliant rear grab bar.The 604.5 Low 3 In Medium Remount the rear grab bar so there is 12"to the closed side and 24"to the open side. 200 Fourth St. bar is 11%"and 24%"to each side of the toilet centerline which is%"to far to the open side. 624 Museum- Restrooms Women's The trashcan in the Museum public women's restroom ADA stall has an outlet distance of 604.7 Medium 3 In Medium Remount trashcan so the outlet is 7-9"from the front edge of the toilet. 200 Fourth St. 16 Y."which is outside the 7-9". 625 Museum- Restrooms Men's The Museum public men's restroom does not have a compliant knee height for the 606.2 High 3 In or Medium Raise counter so the knee height is a minimum of 27". 200 Fourth St. counter and sinks.The bottom of the sink basin has a height of 26%"which is less than Out III the 27"minimum. r 626 s.. Museum- Restrooms Men's The ADA stall in the Museum public men's restroom is not ADA compliant.The door is 606.81.2 High 3 In and High Adjust stall door so it is no more than 4"from the side wall.Adjust or replace hinges so door self- 200 Fourth St. 7/8"from the side wall which is more than the 4"maximum.The door is not self-closing Out closes completely.Add pull handles to both sides of the door Reconfigure the restroom to fix the . and there are no pull handles.The edge of the urinal is 27"from the Ada stall entry maneuvering depth for the ADA stall,may be able to move the door to the middle of the partition 627 which is less than the 48"minimum. wall where the is 56"of depth before the door opening. Museum- Restrooms Men's The Museum public men's restroom toilet centerline is 18Y"from the side wall which is 604.2 High 3 In or High Modify wall or reposition toilet so the toilet centerline is 16-18"from the side wall. 200 Fourth St. over the 18"maximum. Out —- 628 ' Museum- Restrooms Men's The Museum public men's restroom urinal is not ADA compliant The rim height from the 605.2 High 3 In or High Remount or replace urinal so the rim height is less than 17"from the floor. 200 Fourth St. floor is 24%"which is over the 17"maximum. Out 629 Dekker Power and Parking Lot Lower Parking Lot There is one ADA parking space and it is not compliant.The space does not have a 502.3,502.4 High 1 In and High Regrade the ADA parking space and access aisle so the slope is less than 2%in any direction.Mark AM P. Communications- marked access aisle adjoining it and is therefore not connected to the accessible route. Out the access aisle to discourage parking in it. 615 Elm Road The space has a width of 106 Y"The slope of the ADA parking space is 5.77%to 7.69% 2._ 630 which is over the 2%maximum.The cross slope of the space is 8.22%to 12.10%which is over the 2%maximum Dekker Power and Parking Lot Lower Parking Lot The ADA parking space sign is mounted at a height of 37 1/2"which is less than the 60" 502.6 Medium 1 In or Medium Add a pale and raise sign so the bottom height is no less than 60". . Communications- minimum. Out 1 _ 615 Elm Road 631 Dekker Power and Accessible Route South of Building,from The sidewalk along the south side of the P&C building has several spots with vertical 303.2,307.4,403.3 High 1 In and High Repave sidewalk so vertical changes are less than X,"height and the cross slope is less than 2%.Trim .,_ .°—.„._t. _ Communications- lower parking lot changes over%"measuring from 34"to 1 Y"where sections of concrete slab have sunken Out tree so it does not overhang sidewalk. r7.a 615 Elm Road or heaved The sidewalk has a cross slope of42%to857%which is over the 2% Jam , r 632 maximum.Due to the nearby tree,the he height of the route is only 75". �� ,;��r� ' Dekker Power and Accessible Route East of Building by main The sidewalk along the east side of the P&C building has a cross slope of 2.1%to 6.64% 307.4,403.3,405 High 1 In and Medium Regrade sidewalk so the cross slope is no more than 2%.Trim the tree so it does not overhang the .•S Communications- entry door,from lower which is over the 2%maximum.Due to the nearby tree,the height of the route is only Out sidewalk.This section being a ramp will be covered in the ramps section. 615 Elm Road parking lot 67".The slope is 6.47%to 8.22%which makes this section of sidewalk a ramp. 633 Dekker Power and Ramps Southeast of Building, The sidewalk on the east side of P&C is considered a ramp.The cross slope is 2 1%to 405.2,405.7,405.8 High 1 Out High Regrade ramp so the cross slope is less than 2%.Regrade the top and bottom landings so the slope is Communications- from lower parking lot 6.64%which is over the 2%maximum There are no handrails present.The bottom less than 2%in any direction. 615 Elm Road landing has a slope of 4%and cross slope of 2.27%which are over the maximum of 2%. 634 The end of the bottom landing is the top of the flight of stairs.The top landing has a slope of 3.5%and cross slope of 6.12%which are over the 2%maximum. ,'.,� r� Dekker Power and Stairs Southeast of Building, The flight of stairs on the south east side of P&C has non-compliant handrails.The 505.4,505.10 High 1 Out High Redo handrails so the height is 34-38".Add extension at the top of the stairs and on the west �t , ! ' " Communications- from lower parking lot handrails have a height of 45 Y"to48 Y"which is over the 38"maxmum The handrails handrail at the bottom of the stairs.Handrails should extend 12"beyond the first riser at the top and '— —. ' g 615 Elm Road extend 4 IS"beyond the first riser at the top of the stairs which is less than the 12" one treads depth(11")minimum at the bottom g t' 635 minimum.The west handrail s16"short of compliance at the bottom of the stairs. pry"^ �, � ' r - . r. Dekker Power and Entrances Main Entrance for Public The main entrance door is not compliant.The maneuvering clearance on the pull side of 302.2,404.2.4,404.2.5, High 1 Out High Add ADA door openers to both sides of the door.Replace the threshold with an ADA compliant one ' Communications- the door is 16"which is less than the 18"minimum.The maneuvering clearance an the 404.28 that is no more than Y."in height with the top)4"beveled at 1:2.Adjust door closer so door closes in i ^ 615 Elm Road push side of the door is 5%"which is less than the 12"minimum fora door with a latch no less than 5 seconds.Secured rug edges or remove. 4 V ki, , 636 and closer.The thresholds 1)4"high with a'A"vertical change which are over the)4" maximum and%"vertical change maximum The door closes from 90 12°in 4.3 seconds " which is less than the 5 second minimum.Theresa carpeted rug with rubber edges 't,°• present that has unsecured edges. Dekker Power and Entrances Main Entrance for Public The interior door of the main entrance does not have compliant maneuvering space at 5 404.2.4,404.2.8, High 1 Out Medium Add an ADA door opener to both sides of the door.Adjust door closer so door closes in no less than 5 , Y Communications- "en both sides of the door which is less than the 12-18"required.The door closes from 404.2.9 seconds. 615 Elm Road 90-12'in 4 seconds which is less than the 5 second minimum.The doom requires 11.5 a 637 pounds of force to open which is over the 5-pound maximum. 1 ral Dekker Power and Signs Restrooms(Lower Level) The restroom door signs are mounted on the restroom doors at a height of 66''4"which 703.3,703.4,703.6 Low 3 In Low Replace signs with ADA compliant ones that are mounted at an ADA compliant height. Communications- is over the 60"maximum.There is no braille or pictograms. 615 Elm Road 638 Dekker Power and Controls Main Entrance for Public The main entrance has a door bell for guests.The doorbell is located at 51"in height 309.2,309.3 High 2 In and High Regrade and extend concrete surface so there is 30"of width beyond the swing of the door and the in i Communications- which is over the 48"maximum.The clear floor space is 16%"wide which is less than the Out slope is no more than 2%in any direction.Lower the doorbell so the height is 48"maximum. ` 615 Elm Road 30"minimum.The slope is 2.44%which is less than the 2%maximum. , f 639 ,?s 1 Dekker Power and Controls Women's Restroom The light switch for the women's restroom is located at a height of 56".There is a small 309.2,309.3 High 3 Out Medium Lower light switch to 48"maximum or replace with an automatic one with a sensor.Relocate or Communications- table that blocks the clear floor space. remove small table. 615 Elm Road 640 Dekker Power and Controls Men's Restroom The light switch for the men's restroom is located at a height of 56 Y". 309.2,309.3 High 3 Out Medium Lower light switch to 48"maximum or replace with an automatic one with a sensor. Communications- 615 Elm Road 641 Dekker Power and Restrooms Women's The women's restroom does not have compliant turn around space with 51"deep and 603.21 High 3 Out High Reconfigure restroom so there is 60"diameter of turn around space. Communications- 64"wide. 615 Elm Road 642 Dekker Power and Restrooms Women's The door for the women's restroom has 5"of maneuvering space due to a small table. 404.2.4,404.2.7, High 3 Out Medium Replace door with one that has a flat surface on the bottom 10"of the door and ADA compliant door Communications- The door has round knobs for the handle that require grasping.There is a vent screen at 404.2.10 handles. Ili 615 Elm Road the bottom of the door and no kickplate present. 643 Dekker Power and Restrooms Men's The door for the men's restroom requires 10 pounds of force to operate.There is a vent 404.29,404.2.10 High 3 Out Medium Replace door with one that has a flat surface on the bottom 10"of the door.Adjust closer so Communications- screen at the bottom of the door and no kickplate present. maximum force needed to operate the door is 5 pounds 615 Elm Road 644 Dekker Power and Restrooms Women's The women's restroom counter and cabinet do not have ADA compliant knee and toe 606.2 High 3 Out Medium Replace cabinet and counter with and ADA compliant one with compliant knee and toe clearances. Communications- clearances. Insulate exposed drain pipes. 615 Elm Road 645 Dekker Power and Restrooms Women's The toilet seat height in the women's restroom is 1551"which is less than the 17" 604.4 High 3 In Medium Replace with an ADA compliant toilet that has a seat height of 17-19". Communications- minimum. 615 Elm Road 646 Dekker Power and Restrooms Women's The women's restroom does not have a rear grab bar.The side grab bar extends 53%" 604.5 Medium 3 In Medium Add an ADA compliant grab bar on the rear wall with 12"to the closed side and 24"to the open side. Communications- from the rear wall which is less than the 54"minimum.The toilet paper holder is Remount side grab bar so it extends 54"minimum from the rear wall.Move toilet paper holder from 615 Elm Road mounted 4 Y."above side grab bar which is less than the 12"minimum. above bar to below bar with 1%"between top of dispenser and bottom of bar. 647 Dekker Power and Restrooms Women's and Men's The towel dispensers in both restrooms are mounted too high.The women's is 55%"and 604.7 High 3 In Medium Lower towel dispensers so the bottom is no more than 48"in height. Communications- the men's is 57'A"which are over the 48"maximum. 615 Elm Road 648 Dekker Power and Restrooms Men's The men's restroom counter and sinks has knee clearance height of 25 Y."which is less 606.3 High 3 In or Medium Raise counter so the knee height is 27"minimum and insulate drain pipes. Communications- than the 27"minimum.The drain pipes are not insulated. Out 615 Elm Road 649 Dekker Power and Restrooms Men's The stall in the men's restroom is not ADA compliant.The stall width is 4l36"which is 604.8,604.8.1.2 High 3 Out High Reconfigure stall so that it is a minimum of 60"wide.Replace stall door hinges so door is self-closing Communications- less than the 60"required.The door is not self-closing and does not have door handles. and add ADA compliant handles to both sides of the door. 615 Elm Road 650 Dekker Power and Restrooms Men's The toilet in the men's restroom is located 20%"from the side wall which is over thel8" 604.2,604.4 High 3 Out High Replace and remount toilet so it is located 16-18"away from the sidewall and the seat height is 17- Communications- maximum.The toilet seat height is 19%"which is over the 19"maximum. 19". 615 Elm Road 651 Dekker Power and Restrooms Men's The urinal in the men's restroom in not compliant.The stall width is 29%"which is less 605.2,605.3 High 3 Out Medium Reconfigure stall wall so the width is 30'minimum.Lower urinal so the rim height is 17"maximum. Communications- than the 30"minimum.The rim height from the floor is 25%"which is over the 17" 615 Elm Road maximum. 652 Dekker Power and Restrooms Men's The men's restroom stall has a rear grab bar that is 24"long which is less than the 36" 604.5 Medium 3 In Medium Replace rear grab bar with a 36"long one that is mounted with 12"to the closed side and 24"to the Communications- minimum.The height of the grab bars is 36%"and 363/8"which are over the 36" open side with a height of 33"-36".Remount the side grab bar to a height of 33"-36". 615 Elm Road maximum. 653 Dekker Power and Restrooms Men's The toilet paper holder in the men's restroom stall is located 2"from the front of the 604.7 Low 3 In Low Remount toilet paper holder so it is 4-7"from the front of the toilet. Communications- toilet which is less than the 4"minimum 615 Elm Road 654 Water Shop- Parking Lot Upper Lot The ADA parking space is not marked as"Van Accessible".The access aisle and space are 208.2,502.6 Medium 1 In Low Add a"Van Accessible"sign to the post at the front of the ADA parking space. 1360 Brooke Drive of adequate size to be van accessible.The configuration is compliant with the aisle on the driver side since the space is not angled. 655 Water Shop- Parking Lot Upper Lot The back of the ADA space has a slope of 2.44%and an 8.57%slope by the gutter.The 502.4 High 1 Out High Regrade ADA parking space so the slope is less than 2%in any direction. 1360 Brooke Drive rear of the ADA parking space's slope is over the 2%maximum. 656 Water Shop- Accessible Route Near Main Entrance The sidewalk between the main entrance and the water lab entrance has a slope of 3.14%403.3,405 High 1 Out High Regrade with cross slope less than 2%.Will be addressed in ramps section. 1360 Brooke Drive to 16%with a cross slope of 1.92%to 9.28%.The maximum cross slope allowed is 2%. The running slope makes this sidewalk a ramp. 657 Water Shop- Accessible Route Near Water Lab Entrance The sidewalk for the water lab entry has a slope of 9.1%to 16.91%which makes ita 403.3,405 High 1 N/A N/A Will be addressed in ramps section. i ,•r- ?II 1360 Brooke Drive ramp. -- -' 658 Water Shop- Accessible Route Near Main Entrance The sidewalk between the main entrance and the water lab entrance is a ramp The 405.2,405.3,405.7, High 1 Out High Reconfigure the sidewalk/ramp so the maximum running slope is 10%with a maximum cross slope of_ 1360 Brooke Driverunning slope is up to 16%which is over the 10%maximum.The cross slope is 192%to 405.8,405.9 2%Add ADA compliant handrails to both sides of the ramp along with curb banners due to the high . ,m *''=� land%whies is over the 2%maximum There are no handrails present.There is no top of the drop off of the sidewalk. 659 landing present �— • Water Shop- Accessible Route Near Water Lab Entrance The sidewalk for the water lab entry is a ramp.The running slope is up to 16.91%which 405.2,405.8,405.9 High 1 Out High Regrade sidewalk/ramp so the running slope is less than 10%with landings at the top and bottom • , 1360 Brooke Drive is over the 10%maximum.There are no handrails present and a large drop off of several that have a slope less than 2%in all directions.Add ADA compliant handrails to both sides of the - 111 . feet on one side. ramp along with curb barrers. 660 Water Shop- Stairs Main Lobby to Water Lab The stairs from the lobby/reception area to the water lab are not compliant.The riser 504.2 Low 4 Out Medium Redo stairs with uniform riser heights and tread depths. 1360 Brooke Drive heights range from 5%"to 6 A"and there are supposed to be uniform. 661 Water Shop- Entrances Main Entry The main entry doors are not compliant.The threshold for the extenor pair of doors is 302.2,404.2.5,404.2.8 Medium 2 In and Medium Adjust the closer so the doors close m no less than 5 seconds.Bevel the threshold or add a transition 1360 Brooke Drive has a vertical change of 3/8"which is over the Y."maximum.The doors close from 90-12° Out piece so there is no more than a%"vertical change.Remove the entry rugs or secured in place. in 3.1-3.7 seconds which is less than the 5 second minimum.The area is carpeted with 662 secured edges;however,rugs have been added that do not have secured edges but weighted rubber edges. Water Shop- Entrances Water Lab The water lab door has a closer on it and is recessed 9"on the push side with no 404.24 High 2 In and Medium Add an ADA door opener for the door with a button located near the door with compliant clear floor "' a' 1360 Brooke Drive maneuvering space.For a recessed door,12"is required for maneuvering width on the Out space.Secure rug in place. 11; r latch side of the door.There is also a carpeted rug that has unsecured edges. 663 Oilk Water Shop- Signs Conference Room The sign for the conference room is mounted at 605/8"high which is over the maximum 703.4 Low 2 In Low Lower the sign so the text baselines are between 48"and 60". 1360 Brooke Drive of 60"for the height of the highest text baseline. 664 Water Shop- Restrooms Men's and Women's The men's and women's restroom doors are 79 Y."and 79 A"which is less than the 80" 404.23,404.2.4 Medium 3 Out High Replace or adjust doors to an ADA compliant height that is no less than 80".Adjust women's door or 1 1360 Brooke Drive minimum.The women's door has 15"of maneuvering width on the pull side which is less fixtures so there is 18"of maneuvering space width on the pull side of the door. than the 18"minimum. 665 Water Shop- Restrooms Women's The mirror has a bottom reflective edge height of 40 Y."which is over the 40"minimum. 603.3 Low 3 In or Medium Lower the mirror so the bottom reflective edge is no more than 40"high. 1360 Brooke Drive Out 666 44 Water Shop- Restrooms Men's The urinal in the men's restroom is mounted with the rim 17%"from the floor which is 605.2 Medium 3 Out High Lower the urinal so the rim height is no more than 17". 1360 Brooke Drive over the 17"maximum 667 Water Shop- Seating Area Lobby The waiting area seating does not have a configuration that allows for a wheelchair to be 221.2.2 Medium 4 In Low Configure seating so the is a space that is 36"wide and 48"deep minimum and within the main it 1360 Brooke Drive accommodated within the seating. seating area. 668 Water Shop- Reception Counters Lobby The reception counter is not ADA complaint.There is no place for a wheelchair due to 904.4 High 2 In Low Remove one chair to make space for a wheelchair. 1360 Brooke Drive the water department sign and no cut out for the lower counter part.There are chairs on the side counter with no space for a wheelchair. 669 Town Hall- Parking Lots Bond Park(Brick) The north access space slope in the front and middle of the space is 2.6%and 3%while 502.4 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 170 MacGregor Ave. the middle cross slope is 3.9%which are over the 2%maximum 670 Town Hall- Parking Lots Bond Park(Bock) The south access space slope in the front and middle of the space is 2.1%while the cross 502.4 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 170 MacGregor Ave. slope iss measured at 2.6%which are over the 2%maximum. 671 Town Hall- Parking Lots Bond Park(Brick) The access aisle has a slope of 2.6%and a cross of 3%in the middle which are over the 502.4 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 170 MacGregor Ave. 2%maximum 672 �-- Town Hall- Parking Lots Town Hall Rear and The total number of parking spaces is 277 which requires 7 access spaces with 2 being van 208.2 High 1 Out Medium The access space and aisle located in the SW corner of the library lot is the proper size of a van 170 MacGregor Ave. Library Lots accessible spaces.There is only 1 designated van access space.The space is not accessible space.ADD a"Van Accessible"sign to the space.Connect the landing for the curb ramp to connected to the accessible route. the sidewalk along Elkhorn Ave. 673 Town Hall- Parking Lots Town Hall Rear Lot The west access space of the Town Hall rear lot in the southwest corner has a slope of 502.2 High 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. ei 170 MacGregor Ave. 2.1%-4.5%and a cross slope of 2.4%-4.2%which are over the 2%maximum. 674 Town Hall- Parking Lots Town Hall Rear Lot The western access space aisle of the Town Hall rear lot in southwest corner has a slope 502.2 High 1 Out High Level surface of aisle so that there is no more than 2%slope in any direction. 170 MacGregor Ave. of 4.7%and cross slope of 3%.The middle of the aisle has a slope and cross slope of 2.3%,and the rear has a slope of 2.3%.The maximum slope in any direction is 2%. 675 Town Hall- Parking Lots Town Hall Rear Lot The middle west access space of the Town Hall rear lot in southwest corner has a slope of 502.2 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 170 MacGregor Ave. 4.7%and a cross of 2 6%which are over the 2%maximum. .. 676 r s Town Hall- Parking Lots Town Hall Rear Lot The middle east access space of the Town Hall rear lot in the southwest corner has a 502.2,303.2/406 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction.Add a curb cut 170 MacGregor Ave. slope of 9.9%and the rear of the space has a cross slope of 4.5%.The maximum slope in for the access aisle. any direction is 2%.The space is not connected to the accessible route due to no curb cut 677 for the access aisle. Town Hall- Parking Lots Town Hall Rear Lot The east access aisle at rear on Town Hall in the SW corner of rear lot is NOT less than 2%502.3 Medium 1 Out High Level surface of aisle so that there is no more than 2%slope in any direction Add a curb cut for the 170 MacGregor Ave. slope in any direction.The aisle is NOT connected to the accessible route either. access aisle so that the space is connected to the accessible route. 678 Town Hall- Parking Lots Town Hall Rear Lot The east access space ofthe Town Hall rear lot in the southwest corner has a slope of 502.4,303.2/406 Medium 1 Out High Level parking surface so that access space is no more than 2%slope in any direction.Add a curb cut 170 MacGregor Ave. 7.2%and a cross slope of 2.4%which are over the 2%maximum.The space is not for the access aisle so that the space is connected to the accessible route. connected to the accessible route. 679 Town Hall- Parking Lots Town Hall Rear Lot The ADA parking space in the northeast corner of the Town Hall rear lot has a slope of 502.2,502.3 High 1 In Low There are 3 extra ADA spaces.The recommendation is to remove the ADA markings and sign,and " 170 MacGregor Ave. 2.8%which is over the 2%maximum The space is not connected to an accessible route, make this space a normal parking space.That would reduce the total number of ADA parking spaces and the space does not have a compliant access aisle to 9,which is 2 more than needed.Additionally,this ADA parking space is not located nearest to 680 anything such as the buildings the parking lot servers,the library and town hall. Town Hall- Parking Lots Library Lot The east ADA parking space in the northwest corner of the library lot has a slope of 2.8% 502.3,502.4 High 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 49 170 MacGregor Ave. and cross slopes of 2.3%and 3.1%.The maximum slope in any direction is 2%.The space .i is not connected to an accessible route. �� \ 681 Town Hall- Parking Lots Library Lot The access aisle between the east and middle ADA parking spaces in the northwest corner 502.3,502.4 High 1 In and High Level surface of aisle so that there is no more than 2%slope in any direction Restripe middle and 170 MacGregor Ave. of the library lot is not wide enough.It has a cross slope in the front and middle ofthe Out east ADA parking spaces along with the access aisle.There should be adequate space to fit a 96"wid aisle that is 3%and 2.5%which are over the 2%maximum.The access aisle is not ADA parking space,a 60"wide access aisle,and a 96"wide ADA parking space.Add a curb cut to 682 connected to the accessible route. connect the access aisle with the accessible route. Town Hall- Parking Lots Library Lot The middle ADA parking space in the northwest corner of the library lot has a 2.1-3.3% 502.3,502.4 High 1 Out High Level parking surface so that access space is no more than 2%slope in any direction.Add a curb cut 170 MacGregor Ave. cross slope which is over the 2%maximum.The space is not connected to an accessible to the access aisle on the passenger side. route.There is an access aisle on the driver side of the ADA space,however rt is not 683 compliant in width due to being in a triangle shape. Town Hall- Parking Lots Library Lot The west/south ADA parking space in thenorthwest corner of the library lot has a slope of 502.3,502.4 High 1 In and High Level parking surface so that access space is no more than 2%slope in any direction.Restripe parking 170 MacGregor Ave. 4%-5.2%which is over the 2%maximum.The space is not connected to an accessible Out space so that there is an ADA parking space with a width of 96"minimum and an access aisle with a route due to a non-compliant access aisle. width of 60"minimum 684 Town Hall- Parking Lots Library Lot The sign for the west/south ADA parking space in the northwest corner of the library is 502.6 Medium 1 In Low Raise the sign so that the bottom edge is 60"minimum. 170 MacGregor Ave. lower than the minimum height and was measured at 57%". 685 Town Hall- Parking Lots Library Lot The triangle shaped access aisle in the northwest corner of the library lot has a slope of 502.3,502.4 High 1 In and High Level parking surface so that access space is no more than 2%slope in any direction.Restripe to 170 MacGregor Ave. 4.37%and a cross slope of 4.37%on the front which are over the 2%maximum.The aisle Out make a compliant access aisle for the west/south ADA parking space while also marking out the entire width at the front in 58"from centerline to centerline. area to discourage parking. 686 Town Hall- Parking Lots Library Lot The ADA parking space in the southwest corner of the library lot has a slope of 4.9%and 502.4 High 1 Out High Level parking surface so that access space is no more than 2%slope in any direction. 170 MacGregor Ave. a cross slope of 2.8%which are over the 2%maximum. 687 Town Hall- Parking Lots Library Lot The ADA access aisle in the southwest corner of the library lot has a slope of 3%and a 502.3,502.4 High 1 Out High Level parking surface so that access space is no more than 2%slope in any direction.Connect the 170 MacGregor Ave. cross slope of2.5%which are over the 2%maximum The aisle is not connected to the curb ramp landing to the sidewalk along Elkhorn Ave. accessible route. I 688 Town Hall- Parking Lots Library Lot The ADA parking space in the middle of the south row of the library lot has a slope of 502.3,502.4 High 1 In Low Remove ADA markings and sign and make this a normal parking space.With the previous corrective 170 MacGregor Ave. 5.2%which is over the 2%maximum.There is no dedicated access aisle.The access aisle measure in#11 that would reduce the total number of ADA parking spaces to 8,which is 1 more than is shared with the main crosswalk through the parking lot which can cause issues on required.Additionally,this ADA parking space is not located nearest to anything such as the buildings 689 busier days. the parking lot servers,the library and town hall. Town Hall- Passenger Loading Zone Sidewalk-South side of The access aisle for the passenger loading zone on the south side of Town Hall is non- 503.3,503.4 High 1 In Medium Add an access aisle to the passenger loading zone that is the full length of the loading zone and is 60" 170 MacGregor Ave. Town Hall existent.There is one place in the passenger loading zone where the slope was measured wide minimum.Make sure the loading zone and access aisle have a slope less than 2%in any - _ - at2.8%which is over the 2%maximum. direction 690 Town Hall- Accessible Route Sidewalk-South side of The under-deck sidewalk on the south side of Town Hall has a cross slope of 3%which is 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. `I` ' 170 MacGregor Ave. Town Hall over the 2%maximum. . ...+.- '1 - pig' L• igg 691 Town Hall- Accessible Route Sidewalk-NearAdmin The sidewalk for the admin lobby west vestibule has a cross slope of 2.8%which is over 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. I 0 170 MacGregor Ave. Lobby Entrance the 2%maximum A I U:1' 692 Town Hall- Accessible Route Sidewalk-Near Public The sidewalk to the public restroom has a cross slope of 2.1%which is lust over the 2% 403.3 Low 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. 170 MacGregor Ave. Restroom Entrance maximum. 693 Town Hall- Accessible Route Sidewalk-Northwest The sidewalk on the northwest corner of Town Hall has a dip in it for drainage One side 403.3,405 Medium 1 Out Medium Regrade the concrete slabs so that the running slope is less than 5%and the cross slope is less than - 170 MacGregor Ave. Corner of Town Hall of the dip has a slope of 5.42%which is over the 5%maximum.This is to be considered a 2% II"- ramp unless the slope of change is less than 5%.If the slope is not adjusted,a handrail 694 needs to be added. 111"fr • Town Hall- Accessible Route Sidewalk-Northeast The sidewalk along the north side of Town Hall has a cross slope of 3.9%-4.2%which is 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. _ 170 MacGregor Ave. corner of PD wing over the 2%maximum 695 Town Hall- Accessible Route Sidewalk-East side of PD The sidewalk along the east side of Town Hall(PD)has a cross slope of 4.2%which is over 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. 170 MacGregor Ave. wing the 2%maximum. 4404 696 Town Hall- Accessible Route Sidewalk-Northwest The sidewalks on the northwest corner of Town Hall have spots where the cross slope is 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. MT- 170 MacGregor Ave. Corner of Town Hall 2.3%which is over the 2%maximum �" "' - 697 - • Town Hall- Accessible Route Sidewalk-Near PW entry The rear Town Hall sidewalk by the Public Works entry has a cross slope of 4.2%which is 403.3 High 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. 170 MacGregor Ave. over the 2%maximum. 698 • Town Hall- Accessible Route Sidewalk-North side of The sidewalk on the north side of the library has a cross slope of 8.1%which is well over 403.3 High 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. A 170 MacGregor Ave. Library the 2%maximum Most of the cross-slope issues are located near the dumpster enclosure "- 699 ' Town Hall- Accessible Route Sidewalk-North side of The north library sidewalk near the curb ramp and crosswalk to go north/south across 303.2 High 1 Out Medium Level the sidewalk so that the vertical changes are less than 34"and the slope is less than 2%in any i^-'•- 170 MacGregor Ave. Library main town hall lot has section of concrete that has sunk creating non-compliant direction. • _ __ vertical change.The vertical changes were measured to be%"-%"in height 700 Town Hall- Accessible Route Sidewalks-Between Rear The raised walkways/medians in the library lot and between the library and town hall lots 302.3,402.2,403.3 High 1 In and High Level the sidewalk concrete and flag stone so that the slope is less than 2%in any direction,the gaps ! -., 170 MacGregor Ave. Town Hall and Library are not compliant.There are several areas where trees are in the middle and surrounded Out are less than%",and the vertical changes are less than'h"or%"maximum with the top%"beveled at -� - - Lots by large flagstone pieces.Those pieces have shifted and created gaps of 1"-2"and 12. _ -" 1' • 701 vertical lips of%"-1"There are also areas where the width is only 34-38"wide which is less than the 36"width required.Some spots also have a cross slope over 2%, measured at 2.5%is some spots. Town Hall- Accessible Route Sidewalk-North/South The sidewalk/crosswalk that goes north and south across the library lot has a cross slope 403.3 Medium 1 Out High Level the sidewalk so that the slope is less than 2%in any direction. - 170 MacGregor Ave. across Library lot of 2.3%which is over the 2%maximum. 702 Town Hall- Accessible Route Sidewalk-East of Library Sidewalk along the east side of the library that goes north and south has a running slope 403.3 High 1 Out High Regrade so that the running slope is less than 5%or add a handrail to the sidewalk. 170 MacGregor Ave. of 4.7-7%which is over the 5%maximum. --' s- 'a �- 703 Town Hall- Curb Ramps North side of Bond Park The curb ramp on the west of town hall,across the parking lot to Bond Park has a cross 405.3 High 1 Out Medium Regrade curb ramp so that the cross slope is less than 2%. __ ' 170 MacGregor Ave. Lot slope of 2.8%which is over the maximum cross slope of 2%. 704 Town Hall- Curb Ramps North of Bond Park Lot The curb ramp west of town hall,across MacGregor Ave has a cross slope of 2.1%which 405.3,406.3,406.4 High 1 Out High Regrade curb ramp so that the cross slope is less than 2%.Regrade the ramp flares to be less than 170 MacGregor Ave. is over the 2%maximum.The left ramp flare has a slope of 13.7%which is over the 10% 10%slope.Regrade the landing so that the slope is less than 2%in any direction. maximum.The landing has a slope of 6.8%-7.9%and a cross of 2.8%which are over the 705 2%maximum slope in any direction. Town Hall- Curb Ramps Northwest corner of The curb ramp on the NW corner of town hall,across the PB parking lot entry has a 405.3,406.2,406.3, Medium 1 Out Medium Regrade curb ramp so that the running slope is less than 5%and the cross slope is less than 2%. 170 MacGregor Ave. Town Hall gutter counter-slope of 6.3%-9.1%which is over the 5%maximum.The curb ramp has a 406.4 Regrade the ramp flare so that the maximum slope is 5%.Regrade the landing so that the slope and cross slope of 2.3%-3.3%which is over the 2%maximum.The right ramp flare has a cross slope is less than 2%in any direction. 706 slope of 13.2%which is over the 10%maximum.The landing has a slope of 2 3%which is over the 2%maximum. Town Hall- Curb Ramps Northeast corner of PD The curb ramp on the NE corner of Town Hall near the PD has a counter slope of 6.3%- 405.2,406.2,406.3, High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the cross slope is less than 2%. 170 MacGregor Ave. wing 9.1%which is over the 5%maximum.The slope is 8%-8.75%which is over the maximum 406.4 The ramp flares should be less than 8.33%. Jittor of 8.33%.The left flare has a slope of 8.9%which is over the 8.33%maximum for no 707 landing present at the top of the ramp. Town Hall- Curb Ramps Near PW Entry The curb ramp on the rear of Town Hall that feeds the public works sidewalk has a cross 405.3,406.3,406.4 High 1 Out High Regrade curb ramp so that the cross slope is less than 2%.The right curb flare should have a slope 170 MacGregor Ave. slope of2.4%-3%which is over the 2%maximum The right curb flare was measured at less than 10%.The landing should have a slope less than 2%in all directions. 13.5%which is over the 10%maximum.The ramp landing has a slope of 2 1%-2.3%and 708 a cross slope of 4%which are over the 2%maximum. Town Hall- Curb Ramps Southwest corner of The curb ramp on the SW corner of town hall by the passenger drop-off has a slope of 405.2,405.3,406.4 High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the cross slope is less than 2%. - 170 MacGregor Ave. Town Hall 5.42%to 11.4%which is over the maximum of 8.33%.The cross slope is 5.4%-11.4% The landing should be regraded so that the slope is less than 2%in any direction. which is over the maximum of 2%.The slope of the landing was measured at 2.3%which 709 is over the 2%maximum. Town Hall- Curb Ramps North side of Town Hall The curb ramp on the north end of the main town hall parking lot crosswalk has a slope 405.2,405.3,406.3, High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the cross slope is less than 2% 170 MacGregor Ave. lot by EV chargers-north of8.4%which is over the 8.33%maximum.The cross slope is 2.1%which is over the 2% 406.4 The ramp flare should have a slope less than 10%while the landing should be less than 2%in any side of Town Hall maximum.The left ramp flare has a slope of 133%which is over the 10%maximum.The direction 710 crosswalk landing has a slope of 6.3%-8.1%which is over the 2%maximum. Town Hall- Curb Ramps South side of Town Hall The curb ramp on the south end of the main town hall parking lot crosswalk has a counter 405.2,406.2,406.3, High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the cross slope is less than 2%. 170 MacGregor Ave. lot-south side of Town slope of7%which is over the 5%maximum.The curb ramp has a slope of 5.1%-8.75% 406.4 The ramp flares should have a slope of less than 10%.The landing should have a slope less than 2%in Hall crosswalk which is over the 8.33%maximum.The right ramp flare has a slope of 13.2%which is any direction. 711 over the 10%maximum.The landing has a slope of 2.8%-3.3%and a cross slope of 2.1% -3.3%which are over the 2%maximum. Town Hall- Curb Ramps Northwest corner of The curb ramp on the NW corner of the library parking lot has a slope of 8.75%-9% 405.2,405.3,406.3, High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the cross slope is less than 2% 170 MacGregor Ave. Library Lot which is over the 8.33%maximum.The cross slope is 2.3%-2.5%which is over the 2% 406.4 The ramp flares should have a slope less than 10%.The landing should have a slope less than 2%in maximum. r. The left ramp flare has a slope of 155%which is over the 10%maximum.The any direction. _ \ 712 landing has a cross slope of 3.7%-4.5%which is over the 2%maximum. Town Hall- Curb Ramps Library Lot middle median The curb ramp on the west end of the middle median in the library lot has a counter slope 406.2,406.4 Medium 1 Out Medium Regrade the counter slope to less than 5%.Regrade the curb ramp cross slope to less than 2%. 1-h� 170 MacGregor Ave. west end of6.8%which is over the 5%maximum.The landing has a slope of 3%and a cross slope Regrade the landing so that the slope is less than 2%in any direction.An observation was made that _ - - _ of 2.1%which is over the 2%maximum. the curb ramp width could be reduced significantly due to cars parking and overlapping the curb - - - 713 ramp.The minimum ramp width of 36"appears to still be able to be achieved even with cars parked _ on both sides. -- Town Hall- Curb Ramps Corsswalk in Library Lot The curb ramp on the north end of the library parking lot crosswalk has a slope of 8.6%- 405.2,405.3,406.3, High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%and the ramp flare slope is less than I.---] 170 MacGregor Ave. North End 10.2%which is over the 8.33%maximum.The left ramp flare has a slope of 13.7%and 406.4 10%.The route to the accessible pathway should have a cross slope of less than 2% .. _ the right flare has a slope of 10%which are at or over the 10%maximum.The landing is - - 714 connected to the accessible route via a section of sidewalk that is 52"wide,but has a cross slope of 2.6%which is over the 2%maximum. Town Hall- Curb Ramps Corsswalk in Library Lot The curb ramp on the north side of the crosswalk by the middle median in the library lot 405.3,406.2,406.3 Medium 1 Out High Regrade curb ramp so that the counter slope is less than 5%.Regrade the curb ramp so the cross 170 MacGregor Ave. has a counter slope of 6.1%which is over the 5%maximum.The ramp has a cross slope slope is less than 2%.The ramp flare slope should be less than 10%. , .... of 2.1%which is over the 2%maximum.The right ramp flare has a slope of 13.2%which - 715 is over the 10%maximum. ' _ 1111 Town Hall- Curb Ramps Corsswalk in Library Lot The curb ramp on the south side of the crosswalk by the middle median in the library lot 405.2,406.3,406.4 High 1 Out High Regrade curb ramp so that the running slope is less than 8.33%.The curb ramp flares should have a ' - -- y-/- 170 MacGregor Ave. has a slope of8.75%-9.3%which is over the 8.33%maximum.The left ramp flare has a slope less than 10%The landing should have a slope less than 2%in any direction. IWO slope of 11.75%which is over the 10%maximum.The ramp landing has a slope of 4% 716 and a cross slope of 2.6%-3%which are over the 2%maximum. Town Hall- Curb Ramps Corsswalk in Library Lot The curb ramp on the south side of the library lot by the parking lot cross walk has a 405.2,406.2,406.3, High 1 Out High Regrade counter slope and curb ramp so that the slope is less than 8.33%and the cross slope is less -.wt--/1". , _ ;:'. 170 MacGregor Ave. South End counter slope of 6.3%which is over the 5%maximum.The curb ramp has a slope of 8.2%406.4 than 2%.The ramp flares should have a slope less than 10%.The landing should have a slope less -11.6%which is over the 8.33%maximum.The left ramp flare has a slope of 13.3%and than 2%in any direction. _ -t - - 717 the right one has a slope of 12.3%which are over the 10%maximum.The landing has a slope of 5.6%-7%which is over the 2%maximum. _ Town Hall- Curb Ramps Library Lot Southwest The curb ramp on the SW corner of the library lot has a cross slope of 2.5%which is over 402,405 2,405 5, High 1 Out High Regrade curb ramp so that the cross slope is less than 2%.Reduce the width of the curb ramp to align ' •.- - L+ d, :;'-_ 170 MacGregor Ave. corner by Book drop-off the 2%maximum The landing has a width of 60"which is less than the ramp width.The 406.4 better with the width of the landing Regrade the landing so that the cross slope is less than 2%in an landing has a cross slope of3.2%which is over the 2%maximum.The curb ramp and direction Connect to landing to the sidewalk along the north side of Elkhorn Ave. -. 718 landing are not connected to anything and dead ends at a boulder ----.- - milk Town Hall- Curb Ramps Library Lot west side The curb ramp on the west end of the library lot,south of the library,has a counter slope 405.2,405.3,406.2, High 1 Out High Regrade curb ramp so that the counter slope and running slope are less than 8.33%and the cross ; - 170 MacGregor Ave. of5.4%which is over the 5%maximum.The curb ramp has a slope of 9.3%which is over 406.3,406.4 slope is less than 2%.The ramp flare should have a slope less than 10%.The landing should have a the 8.33%maximum.The cross slope is 2.8%-3.9%which is over the 2%maximum.The slope less than 2%in any direction. .....,. . 719 right ramp flare has a slope of 35.8%which is over the 10%maximum.The landing has a cross slope of 5.8%-6%which is over the 2%maximum. ;6* �' " Town Hall- Ramps Board Room Lobby The ramp to the board room lobby has a partial handrail of 103"on the west side that 405.7,405.8 High 1 Out Medium The ramp has a height greater than 6",so a handrail on each side is required.The top of the handrail .s 170 MacGregor Ave. Entrance has a height of 43`/.".The handrail does not extend past the bottom of the ramp and should have a height of 34-38".The handrail should extend 12"minimum beyond the top and bottom �.� -- extends 6"beyond the top.The bottom landing of the ramp has a slope of 2.5%which is of the ramp.The ramp landings should have a slope less than 2%in any direction. 720 over the 2%maximum Town Hall- Ramps Board Room Lobby The ramp to the board room lobby is heated for the winter.The sidewalk heating has 302.1 Medium 1 Out High Redo the sidewalk heating so that it keeps the ramp clear from snow and ice buildup for the winter. 170 MacGregor Ave. Entrance become degraded to the point of not working very well and allowing ice to build up on it Look at doing the top and bottom landings as well along with the stairs. making it difficult to use for a wheelchair when iced over or heavily covered in ice melt. 721 Town Hall- Ramps Sidewalk-North of Town The ramp on the north side of Town Hall near the rear door of the board room has a 405.3,405.5,405.7, Medium 1 Out High Regrade the ramp and top landing so that the cross slope is less than 2%.The ramp height is 536"and 170 MacGregor Ave. Hall cross slope of2.5%-3.2%which is over the 2%maximum.There are no handrails 405.8 a handrail is required at 6"and greater.The landing width is adequate despite the reduction. present.The top landing width is reduced to 62",which is 4%"less than the ramp width, 722 due to materials(column and stone)attached to the walls.The top landing cross slope is 4.4%which is over the 2%maximum Town Hall- Ramps Southwest corner of The ramp on the SW corner of Town Hall has a height estimated to be 12"and there is 405.7,405.8 Medium 1 Out Medium Add handrails to both sides of the ramp that are ADA compliant.Reduce the ramp width to be more sr.. 170 MacGregor Ave. Town Hall NO handrail.The landing widths are less than the ramp width.The ramp width is 89%" aligned with the widths of the top and bottom landings. while the bottom landing is 41"wide and the top is 59%"wide. 723 Town Hall- Stairs Board Room Lobby The board room lobby stairs at the main entry for Town Hall does not have uniform riser 504.2,505.10 Low 1 Out High Redo stairs so that the tread depths and riser heights are uniform.Redo handrails so that they extend 'k'" - 170 MacGregor Ave. Entrance heights or tread depths.The riser heights range from 5"to 5%"and the tread depths one tread depth beyond the last riser nosing at the bottom and 12"minimum beyond the first nosing -41 1' range from 13`/."to 14%"Additionally,the handrail extends 8"which is 5"less than the at the top. 724 tread depth which is the minimum.At the top of the stairs,the left handrail extends 3" which is less than the 12"depth that is required. Town Hall- Stairs East side of Town Hall The northern section of stairs underneath the dispatch deck has tread depths that are too 504.2,505 Low 1 Out Medium Remove stairs and make area a ramp.This will improve the accessible route around the building. - f,.' 170 MacGregor Ave. Underneath Deck short.The tread depth is 9 fg"while the minimum is 11".There are also no handrails . _, .A(�,---'- 725 present. , Town Hall- Stairs East side of Town Hall The southern section of stairs underneath the dispatch deck has tread depths that are too 504.2,505 Low 1 Out Medium Remove stairs and make area a ramp.This will improve the accessible route around the building. ‘--, WAN � 170 MacGregor Ave. Underneath Deck short and riser heights that are not uniform.The tread depth is 10%"while the minimum is 11"The riser heights are 5"and 5%".There are also no handrails present. k' 726 • 4100 Town Hall- Stairs Stairwell to Deck The rear Town Hall stars need the handrail fixed to be compliant.The top of the handrail 505.3,505.4,505.10 Low 1 Out Medium The handrails need to be corrected so the height is uniform and at a height of 34-38".Both sides f' �!. 170 MacGregor Ave. s too high at 38 f." 39 0"where the maximum is 38" The left handrails not need to be continuous through the entire length of the stairway.The rght handra l bottom w ll not _ ('� •t�i „v„ �'--• ' ,fir:1 continuous and has a break between the flights of stairs.The right rail of the top section be compliant due to not having the physical space to extend the handrail one tread depth beyond the -� 727 extends 3"past the first riser at the bottom where the minimum is one tread depth(11" last riser.Having the handrail continuous should be compliant enough to be considered ok along with ."c min). the right one being continuous as well. _ 1 Town Hall- Stairs Southside of Town Hall The west section of stairs on the south side of Town Hall do not have a uniform riser 504.2,505 Low 1 Out Medium Make riser heights uniform between 4"and 7".Add an ADA compliant handrail to both sides of the 170 MacGregor Ave. heights measured at 5"and 6".There is no handrail present. stairs. f . . 728 ..4. -��' Town Hall- Stairs Southside of Town Hall The east section of stairs on the south side of Town Hall do not have uniform riser height 504.2,505.2 Low 1 Out Medium Make the riser heights and tread depths uniform.Add ADA compliant handrails to both sides of the _'' 170 MacGregor Ave. or tread depths.The riser height was measured at 5 Y."and 6"while the tread depths stairs. were 729 • measured at 18%"and 19"There is one section of handrail in the middle of the stairs Town Hall- Stairs 2nd Floor Emergency Exit The second-floor emergency exit has a raised landing with stairs and does not have a 505 Low 1 Out Medium Add an ADA compliant handrail on each side of the stairs. 170 MacGregor Ave. Door handrail. .Vistoril,11:41114E 730 Town Hall- Entrances Board Room Lobby The board room lobby vestibule exterior doors close too quickly.The left was measured 404.2 8,404.2.10 Medium 1 In Low Adjust closers so that doors close from a 90°to 12°position in 5 seconds minimum.Kickplates are 170 MacGregor Ave. Entrance at 2 seconds and the right was measured at 3.5 seconds which are both less than the 5 required for 0-10"height from the bottom.There are ADA push buttons to open the doors without second minimum.The bottom rail/shoe has an angle of 56.31°which is less than the 60' the need to touch them.Replace the bottom rail/shoe with one that has a 60°angle at a minimum, -' I-' 731 minimum. or replace the glass doors with ADA compliant ones -1 if..L1 6' .! Town Hall- Entrances Public Restrooms The public restroom lobby exterior doors close too quickly.The left was measured at 2.7 404.2.8,404.2.10 Medium 1 In Low Adjust closers so that doors close from a 90°to 12°position in 5 seconds minimum.Kickplates are 170 MacGregor Ave. seconds and the right was measured at 2.5 seconds which are both less than the 5 second required for 0-10"height from the bottom.There are ADA push buttons to open the left door I ��L il' .0y�,,.oCJ4 • minimum.Neither door has a kickplate present.The bottom rail/shoe has an angle of without the need to touch it.Replace the bottom rail/shoe with one that has a 60'angle at a _ F i 732 56.31°which is less than the 60°minimum. minimum, replace the glass doors with ADA compliant ones. " Town Hall- Entrances Admin Lobby Entry West The west admin lobby exterior door has a rubber mat present.The edges are not 302.2 Low 1 In Medium Securely attach edges of mat to the ground. • . 170 MacGregor Ave. securely attached to the ground and the mat could roll up due to a wheelchair. • 733 ill ,+ I. 1 IIII 7 Town Hall- Entrances PD Rear Entry The north exterior door to the PD has a non-compliant maneuvering widths for the pull 404.2.4,404.2.6, Low 1 Out Medium Adjust the maneuvering space so the slope is less than 2%in any direction.Adjust the closer so the 170 MacGregor Ave. side with a slope of 2.6%which is over the 2%maximum.There is an interior door 404.2.8 door closes in 5 seconds minimum. ;4 creating doors in asenes that have 47%"between them which is less than the 48" 734 minimum.The door closed too quickly at 2.4 second which is less than the 5 second minimum. - - Town Hall- Entrances PD Rear Entry The interior door of the north PD entrance is in a series and located too close to the 404.24,404.2.6, Low 1 In Low The doors enter into a secured area.These doors would only be operated by a citizen when — 170 MacGregor Ave. exterior door at 47%"which is under the 48"minimum There is 15"of maneuvering 404.28,404.2.9 accompanied by police department personnel.Adjust closer so the force required is less than 5 ^ i 735 space on the pull side of the door which is less than the 18"required The door closed too pounds and it closes in no less than 5 seconds. .q quickly at 3.5 second which is less than the 5 second minimum.The door requires a force of 13%pounds to operate which is over the 5-pound maximum -- Town Hall- Entrances Admin Lobby Entry East The east admin lobby vestibule exterior door has a maneuvering clearance width of 14" 302.2,404.2.4, Low 1 Out High Move the boot scrap a minimum of 18"away from the doorway.Secured edges of rubber mat. __ _ 170 MacGregor Ave. which is less than the 18"minimum due to the boot scraped.The bottom height of the 404.2.11 Enlarge window so bottom height is 43"maximum or replace door with an ADA compliant one. ,,,-� window in the door is 515/8"which is over the maximum of 43".There is a rubber mat �,10, -I T3 {I 736 present with the edges unsecured that could roll up due to a wheel chair. T"y • Town Hall- Entrances PW Entry The public works door closes too quickly at 3.5 seconds which is less than the 5 second 302.2,404.2.8, Low 1 In and Medium Adjust closer so the door closes from a 90°to 12°position in 5 seconds minimum.Secured edges of - -� 170 MacGregor Ave. minimum.There is a window present with a bottom height of 51''4"which is more than 404.211 Out rubber mat.Enlarge window so bottom height is 43"maximum or replace door with an ADA the 43"maximum There is a rubber mat present with the edges unsecured that could compliant one I k�" 737 roll up due to a wheel chair EI I Town Hall- Entrances 2nd Floor Emergency Exit The 2nd floor emergency exit door has a rubber mat with unsecured edges. 302.2 Low 1 In Low Secure the edges of the mat. 170 MacGregor Ave. Door a 738 �- Town Hall- Entrances Board Room Lobby The interior doors of the board room lobby vestibule close too quickly with the left 302.2,404.2.8,404.2.9, Low 1 In Low Adjust closers so both door close in 5 seconds minimum.The right door force is over the maximum; ',. t.g .bb 9xRb 170 MacGregor Ave. Entrance closing in 3.23 second and the right in 4 8 second which are less than the 5 second 404.210 however,this door is operated with an ADA push button.Add a kickplate to both doors.Secured the j !w'■Ly, minimum.The right door also requires a 6-pound force which is over the 5-pound edges of the carpet/rubber mat.Replace the bottom rail/shoe with one that has a 60°angle at a Fi' P£ EI 739 maximum.There is a carpeted mat with rubber edges that is unsecured.The bottom minimum,or replace the glass doors with ADA compliant ones. ". a 't InP1 77. rail/shoe has an angle of 56.31°which is less than the 60°minimum ' Town Hall- Entrances Admin Lobby Entry West The interior door of the west admin lobby vestibule has a rug with unsecured weighted 302.2 Low 1 In Low Secure the edges of the mat. - 170 MacGregor Ave. edges. ' I, II j • 740 Town Hall- Entrances Admin Lobby Entry East The interior door of the east admin lobby vestibule requires a force of 14 pounds to 404.29,404.2.11 Low 1 In Medium The door is operated with an ADA push button but need to see if closer can be adjusted to reduce 170 MacGregor Ave. operate the door.There is a window in the door with a bottom height of 51"which is force required to open.Enlarge window so bottom height is 43"maximum or replace door with an over the 43"maximum. ADA compliant one. 741 Town Hall- Entrances PW Entry The interior door of the public works vestibule has a maneuvering clearance width of 2 404.2.4,404.2.8 Low 1 In Low Adjust the closer so the door closes from a 90°to 12°position in 5 seconds minimum. " n 170 MacGregor Ave. Y.".The door closes in 4.75 second which is less than the 5 second minimum." `ur.r 4Y 742 Town Hall- Entrances Board Room The entry door to the board room has the pull handle at a height of 31-3636".The 404.27,404.2.8, Low 2 In Medium Adjust the door closer so the door closes from a 90°to 12°position in 5 second minimum and ,�-'�� 170 MacGregor Ave. minimum is 34".The door closes in 3 seconds which is less than the 5 second minimum 404.29,404.2.10, requires 5 pounds of force maximum to operate.Adjust or replace the kickplate so the bottom 10"of '■f 'h The door requires a force of 6 pounds to open.The kickplate is at 9 "which is less than 404.211 the door are protected.Enlarge window so bottom height is 43"maximum or replace door with an 4 743 the 10"minimum.The bottom height of the window in the door is 50"which is over the ADA compliant one. 43"maximum The maneuvering clearance overlaps the Sundance room door Town Hall- Entrances Sundance Room The entry door to the Sundance room has a maneuvering clearance slope that is barely 404.2.8,404.2.10, Low 2 In and Medium Adjust the door closer so the door closes from a 90°to 12°position in 5 second minimum.Replace -'"' 170 MacGregor Ave. compliant at 1.92%with the maximum being 2%.The door closes too quickly at 4.5 404.2.11 Out kickplate so that the height is 10"minimum.Enlarge window so bottom height is 43"maximum or seconds.There is a kickplate on the door that has a height of 9%".There is a window replace door with an ADA compliant one. 744 present in the door that has a bottom height of 50"which is over the 43"maximum.The maneuvering clearance overlaps the Board room door. Town Hall- Entrances Twin Owls Room The Twins Owls door has a maneuvering clearance of 13%"which is less than the 18" 404.24,404.2.8, Low 2 In and Medium Door is typically left open when room is in use.An ADA door opener could be added to make it .gym • 170 MacGregor Ave. minimum.The door closes too quickly at 4.5 seconds which is less than the 5 second 404.2 9,404.2.10, Out compliant.Adjust the door closer so the door closes from a 90°to 12°position in 5 second minimum minimum.The door requires 6 pounds of force to operate which is over the 5-pound 404.2 11 and requires 5 pounds of force maximum to operate.Replace kickplate so that the height is 10" 745 maximum.There is a kickplate that has a height of 9%"which is less than the 10" minimum.Enlarge window so bottom height is 43"maximum or replace door with an ADA compliant minimum.There is a window present in the door that has a bottom height of 50"which one. is over the 43"maximum. Town Hall- Entrances Movable Walls Door The door of the moveable wall in the Twin Owls room requires 8.5 pounds of force to 404.2 9 Low 2 In Low Adjust door so that it can be operated with a 5-pound maximum force. __ 170 MacGregor Ave. Opening operate which is over the 5-pound maximum I ,a 746 Town Hall- Entrances Ramp from board room The door at the bottom of the ramp from the board lobby to the public restroom lobby 404.2.4,404.2.8, Low 2 In and Medium Add an ADA opener for the door to be compliant.Adjust the door closer so the door closes from 170 MacGregor Ave. lobby to public restroom has a maneuvering clearance of 15%"which is less than the 18"minimum.The door 404.2.9 Out 90°to 12°position in 5 second minimum and requires 5 pounds of force maximum to operate. lobby closes too quickly at 4.25 seconds which is less than the 5 second minimum.The door PI I 747 requires 10 pounds of force to operate which is over the 5-pound maximum. Town Hall- Entrances Near Utility Billing Lobby The door separating utility billing from the south half of Town Hall requires a force of 7 404.29 Low 2 In Low Adjust the door closer so the door closes from a 90°to 12°position in 5 second minimum and 170 MacGregor Ave. pounds to operate which is over the 5-pound maximum. requires 5 pounds of force maximum to operate. Lt 748 Town Hall- Entrances Administration The entry into the administration department has two doors in asenes that have a2"gap 404.2.6,404.2.8, Low 2 In Medium The wood door is left open during operating hours so the doors in a series issue is not an ongoing _ 170 MacGregor Ave. between the wood and glass doors and the minimum is 48".The glass door requires 10 404.2.11 issue.Adjust the closer on the glass door so the force required to operate is less than 5 pounds.Add — pounds of force to open which is more than the 5-pound maximum.The bottom a kickplate to both doors.Replace the bottom rail/shoe with one that has a 60°angle at a minimum, 749 rail/shoe of the glass door is flat and not angled to the 60°minimum. or replace the glass doors with ADA compliant ones. Town Hall- Entrances Administration The door to the administration meeting room does not have an ADA compliant door 404.27 Low 2 In Medium Replace the door handle with an ADA compliant one that does not require grasping to operate. 170 MacGregor Ave. handle. 750 Town Hall- Entrances Public Works The door to the Public Works department has the floor surface with a slope of 1.92% N/A Low 2 In Low The door is left open during operating hours. 170 MacGregor Ave. which is just under the 2%maximum limit. -- 751 Town Hall- Entrances Public Works The door to the meeting room in Public Works has a maneuvering clearance of 714"while 404.24,404.2.7 Low 1 In Low Move in room items to create 18"of maneuvering width with 60"of depth.Replace the door handle - 170 MacGregor Ave. the minimum is 18".The slope of the floor surface is 2.1%which is just over the 2% with an ADA compliant one. P. � . 752 maximum.The door handle is not able to be operated without grasping. ""' r�.'II r Town Hall- Entrances Finance The south door of the finance department meeting room has a maneuvering clearance 404.2.4,404.2.8 Low 2 In Low Rearrange items in room so there is 18"wide and 60"deep of maneuvering clearance for the door. 170 MacGregor Ave. depth of 32"which is less than the 60"minimum.The door closes too quickly at 4 Adjust the door closer so the door closes from a 90°to12°position in 5 second minimum. Ft seconds which is less than the 5 second minimum. 753 t Town Hall- Entrances Restorative Justice The entry into Restorative Justice has two doors in a series that are separated by 10'A" 404.24,404.2.6, Low 2 In Medium The wood door is typically left open during operating hours.Adjust the door closer so the door closes Y. . — 170 MacGregor Ave. The wood door does not have any maneuvering clearance due to the doors being in a 404.2 8,404.2.10, from a 90°to 12°position in 5 second minimum.Replace the bottom rail/shoe with one that has a ' — ` ' series.The glass door closes too quickly at 3.5 seconds which is less than the 5 second 404.2 11 60°angle at a minimum,or replace the glass doors with ADA compliant ones. 11 7'� m.The glass door does not have a kickplate present The bottom rail/shoe of the glass door is flat and not angled to the 60°minimum. Town Hall- Entrances Community Development The entry into Community Development has two doors in a series that are separated by 404.2.3,404.2.4, Medium 2 In and Medium The wood door is typically left open during operating hours.Adjust items in hallway so there is 18" 170 MacGregor Ave. 11".The wood door does not have any maneuvering clearance due to the doors being in 404.2.6,404.2.11 Out minimum of maneuvering clearance width.Adjust glass door so there is a width of 32"minimum or while the glass door has 17%"of width which is less than the 18"minimum.The replace glass door.Replace the bottom rail/shoe with one that has a 60°angle at a minimum,or i i - 755 glass door has a width of 31%"which is less than the 32"minimum.The bottom replace the glass doors with ADA compliant ones. rail/shoe of the glass door is flat and not angled to the 60°minimum. Town Hall- Entrances Buildings The entry into the Buildings department has two doors in a series that are separated by 404.2 4,404.2.6, Low 2 In Medium The wood door is typically left open during operating hours.Replace the wood door handle with an 170 MacGregor Ave. 11'''/".The wood door does not have any maneuvering clearance due to the doors being 404.2 7,404.2.11 ADA compliant one.Replace the bottom rail/shoe with one that has a 60°angle at a minimum,or in a es.The wood door does not have an ADA compliant handle.The bottom replace the glass doors with ADA compliant ones. F 756 rail/shoe of the glass door is flat and not angled to the 60"minimum. • Town Hall- Entrances Rooms 201 and 202 The doors to rooms 201 and 202 are located next to each other and have maneuvering 404.2.4 Low 2 In Low The doors to rooms 201-203 are typically left open when public meeting is taking place in the room. 170 MacGregor Ave. clearances that overlap the door swing. Confirm that when room is used by members of the public that the doors remain completely open. 757 Town Hall- Accessible Pathway Board Room In the board Room,when the moveable walls are setup,the walkway between the wall 403.3 Medium 2 N/A N/A None 170 MacGregor Ave. and last row of fixed seating has a cross slope of 1.92%which is just under the 2% maximum. 7 • 758 Town Hall- Accessible Pathway Hallway by Twin Owls The fire extinguisher in the hallway to the Twin Owls room protrudes 5"with a leading 307.2 Medium 2 In Medium Replace cabinet with one the projects less than 4"from the wall or add a bottom portion tothe 1 . Iy14 170 MacGregor Ave. room edge of 34"which are not compliant. cabinet so the leading edge is a maximum of 27"from the ground. fir``,{ 759 Town Hall- Accessible Pathway Police Department Lobby The PD phone in the PD lobby protrudes 5"with a leading-edge height of 38" 307.2 Medium 2 In Medium There is a desk/sitting area next to the phone that limits the protrusion.Add a bottom edge to the i. 170 MacGregor Ave. phone so the leading edge is less than 27". R fill 760 . Town Hall- Accessible Pathway Public Works Hallway The water fountains outside of the Public Works department protrude 19"with a leading-307.2 Medium 2 In Medium Add a surround to the bottom of the water fountain so the leading edge is less than 27"in height. ' 170 MacGregor Ave. edge height of 32%". 761 Town Hall- Ramps Ramp from board room The ramp to the public restrooms from the board room lobby has handrails that extend 405.8 Medium 2 Out Medium Adjust handrails so they extend 12"minimum beyond the end of the ramp.Make sure they do not 170 MacGregor Ave. lobby to public restroom 4"beyond the end of the ramp at the top. protrude more than 4"with a leading edge between 27"and 80".If they do protrude more than 4", 44 lobby make sure the leading edges is less than 27". 1 I j __ 762 Town Hall- Ramps Public Restrooms The ramp in the public restroom area that leads to the utility billing hallway has handrails 405.8 Medium 2 Out Medium Adjust handrails so they extend 12"past the top and bottom of the ramp ends.Make sure they do 411 ` 170 MacGregor Ave. that are not compliant.The north handrail extends 6"beyond the ramp at the bottom not protrude more than 4"with a leading edge between 27"and 80".If they do protrude more than and is 3 5/8"short of the ramp end at the top.The south handrail extends 4 IS"beyond 4",make sure the leading edges is less than 27". —T.763figlifilli*the ramp at the bottom and is 3 M"short of the ramp end at the top. Town Hall Ramps 8ear6-Ream 405.1 Exception-not Medium U Out Medium rr "79-MacGregor-Ave: s--r,-^^'y^6""- •vh-the-n•evea'•Ic.walls a•c sc'••p. required 764 II Town Hall- Ramps 2nd floor hallway by The second-floor hallway ramp has a slope that is too steep at 10.33%which is over the 405.2,405.8 Low 2 Out Medium Add ADA compliant handrails to both sides of the ramp.Make sure they do not protrude more than 11 gt - 170 MacGregor Ave. south stairwell 10%maximum.There are no handrails present. 4"with a leading edge between 27"and 80".If they do protrude more than 4",make sure the leading edges is less than 27". 765 Town Hall- Stairs North stairwell The north stairwell does not have compliant or uniform riser heights,measures from 6" 504.2,505.10 Low 2 Out High The riser heights should be between 4-7".The handrails should extend 12"beyond the first riser J 170 MacGregor Ave. to8"where the height should be between 4"and 7".The handrails are 3-3)1"short of nosing at the top and one tread depth,11"minimum,beyond the last riser nosing at the bottom ( j ' --fie •/// the last riser at the bottom and 1-4"short of the first riser at the top. I / 1 766 Town Hall- Stairs South stairwell The south stairwell does not have uniform riser heights and measure from 6%"to 7". 504.2,505.10 Low 2 Out High Riser heights and tread depths should be uniform with risers 4-7"and treads 11"minimum.The T �_ 170 MacGregor Ave. The tread depths are not uniform and measure 11"to 11'k".The handrails are 4"short handrails should extend 12"beyond the first riser nosing at the top and one tread depth,11" - of the last riser at the bottom and 2"short of the first riser at the top. minimum,beyond the last riser nosing at the bottom. — - --- - Town Hall- Stairs PD lobby and Utility Billing The stairs from the PD lobby to the utility billing area do not have uniform riser height 504.2,5054,505.10 Medium 2 Out High Redo the stairs so that riser heights and tread depths are uniform.Risers should be 4-7"in height and 9 . • .,j 170 MacGregor Ave. lobby Risers measure 6%"-7".The tread depths are to shallow at 10%",which is less than the treads should be 11"minimum in depth The handrails need to be fixed so that the height is 34-38" 11"minimum.The east handrail has a height of 40".The west handrail is 4"short of the and they extend 12"beyond the first riser at the top and one tread depth past the last riser nosing at 768 last riser at the bottom and extends only 9"beyond the first riser at the top which is less the bottom than the 12"minimum. Town Hall- Stairs Board Room The stairs in the board room have non-compliant handrails.The left handrail has a height 505.4,505.10 Low 2 Out Medium Fix both handrails so the height is 34-38"and they extend one tread depth(11"minimum)beyond the - 170 MacGregor Ave. of 39"which is over the 38"maximum.The right handrail extends 9%"past the last riser last riser at the bottom and 12"minimum beyond the first riser at the top. at the bottom and is 4%"beyond the first riser at the top.The left handrail is 4%" 769 beyond the last riser at the bottom and 414"beyond the first riser at the top. Town Hall- Elevator By Admin lobby The elevator is not compliant.The cab dimensions were measured at 60"wide and 39" 407 High 2 Out High The elevator needs to be replaced with an ADA compliant one.This can either be a replacement in 170 MacGregor Ave. deep.The door is offset with a width of 32 Y.".The time between the door stops closing the current location or an elevator added to an exterior wall of town Hall. % ! 't jt and starts closing again is 6 seconds There are no visual signals of the cab arrival and only audio signal comes from inside of the cab and is hard to hear when waiting on the 770 landing for it.The floor designation has a centerline height of 60%".There is only 17)1" of maneuvering clearance width for the 1st floor call buttons and are recessed 16 5/8". I. ill' The in-cab controls have the height of the highest button measured at 52%". Town Hall- Assembly Areas Board Room The board room has 3 ADA seating spaces located in the front row of the fixed seating. 802 High 2 In Medium Adjust seating layout to allow for ADA seating in the moveable seating area.Need to have ADA '�7' 170 MacGregor Ave. There are 2 companion seats that are the nearest fixed seat to the opening for a seating spaces all with companion seats.The ADA seating needs to be dispersed through the seating a 4:ffiYts ,a wheelchair.The east opening is to shallow for a forward approach without blocking the layout,include aisle seating,and have the same line of sight as other seating. I' c / 771 stairs The ADA seating is located only in the first row,and there are no aisle ADA spaces. , ' - � -.,.- , Town Hall- Assembly Areas Board Room The assistive listening devices need to have another set of headphones so all three sets 706 Medium 2 In Low Update theassistive listening device signs with the current international symbol.Add headphones to 170 MacGregor Ave. are working and available.The signage in the room for theassistive listening devices third set of assistive listening devices. al needs to be updated with the current international symbol for assistive listening. 772 r Town Hall- Assembly Areas Board Room The east ADA wheelchair space in the front of the board room is 7%"in depth before the 802.1 High 2 In Low This space is not able to be used as a wheelchair space unless the stairs are blocked off from use. 170 MacGregor Ave. stairs The minimum is 48"for a front approach. 773 r ) Town Hall- Reception Areas Community Development The community development reception seating does not have an ADA wheelchair space. 802.1 High 2 In Medium Configure seating area so there is an ADA wheelchair space that is 36"wide and 48"deep. 170 MacGregor Ave. 774 d1 Town Hall- Reception Areas Public Works The public works reception seating does not have an ADA wheelchair space 802.1 High 2 In Medium Configure seating area so there is an ADA wheelchair space that is 36"wide and 48"deep. 170 MacGregor Ave. 775 Town Hall- Reception Areas Administration The administration reception seating does not have an ADA wheelchair space. 802.1 High 2 In Medium Configure seating area so there is an ADA wheelchair space that is 36"wide and 48"deep. _ �. 170 MacGregor Ave. y 776 Town Hall- Reception Areas PD lobby The police department reception seating does not have an ADA wheelchair space 802.1 High 2 Out High Replace counter so there is enough knee/toe clearance for a wheelchair and remove one of the ' MN 170 MacGregor Ave. chairs. _......,„ N 777 • I Town Hall- Reception Areas Board Room Lobby The board room lobby reception seating does not have an ADA wheelchair space. 802.1 Medium 2 In Medium Configure seating area so there is an ADA wheelchair space that is 36"wide and 48"deep. _ J • 170 MacGregor Ave. • 778 h `Q' _ \ Town Hall- Sales and Service Counters Administration The administration reception counter is not ADA compliant The countertop height is 40 904.4 High 2 Out Medium Replace or add an ADA compliant counter. xir ^ , 170 MacGregor Ave. '/."which is over the 36"maximum.There is no space underneath the counter for a - - forward approach,but there is space fora parallel approach. 779111 Town Hall- Sales and Service Counters Public Works The public works counter is not Ada complaint.The countertop is 431/2"high which is 904.4 High 2 Out Medium Replace part of the counter with an ADA compliant one with a maximum height of 36"and a depth of ' 170 MacGregor Ave. over the 36"maximum which no cutout for a lower counter. 17". 780 Town Hall- Sales and Service Counters Community Development The community development reception counter does not have enough clear floor depth 304 High 2 In High Move reception chair closest to door.Move counter back far enough for complaint depth for the 170 MacGregor Ave. at 36"which is less than the 48"minimum.There is enough room fora parallel approach, counter as well as create an ADA wheelchair reception space. but there is no adequate turn around space. o 781 N. Town Hall- Sales and Service Counters Buildings The buildings department reception counter is not Ada compliant.The left part of the 304 High 2 In High Move the desk back and the side table over so there is a 60"diameter circle for turnaround space ).;It 170 MacGregor Ave. counter does not have any clear floor space underneath the counter.The right part of 'l 11.S 11 , ..� the counter does not have enough depth for a forward approach at 37%"which is less •782 than the 48"minimum.There is no adequate turn around space. Town Hall- Sales and Service Counters PD lobby The PD reception counter is not Ada compliant.The countertop has a height of 411/2" 904.4 High 2 Out Medium Replace counter with an ADA compliant one. I-a " 170 MacGregor Ave. which is over the 36"maximum. I 783 J45°W. Town Hall- Sales and Service Counters Utility Billing The left utility billing window counter is not ADA complaint.The countertop height is 39 904.4,306 High 2 Out High Replace the counter with an ADA compliant one. r '"ate 170 MacGregor Ave. "which is over the 36"maximum.The depth under the counter is 11/2"which is less than the 17"minimum and there is no room for a parrallel approach. ]i - �� Y."784 Town Hall- Sales and Service Counters Utility Billing The middle utility billing window counter is not ADA complaint.The countertop height is 904.4,306 High 2 Out High Replace counter with an ADA compliant one. ' 170 MacGregor Ave. 39 Y."which is over the 36"maximum.The depth under the counter is 1'h"which is less than the 17"minimum and there is no room fora parrallel approach. - �� 785 AIM Town Hall- Sales and Service Counters Utility Billing The right utility billing window counter is not ADA complaint.The countertop bottom 306 High 2 Out High Replace counter with an ADA compliant one. �g ' atcRwuov 170 MacGregor Ave. height is 26%"which is under the 28"minimum.The depth under the counter is 1'A" li a which is less than the 17"minimum and there is no room for a parrallel approach. �� 786 - Town Hall- Signs Town Hall The majority of permanent room signage is not ADA compliant with missing braille and 703 High 2 Out High Replace at Town Hall permanent room signage with signs that have braille,raised characters.Locate 170 MacGregor Ave. raised text being the main issues. on latch side of the door,when possible,at a height of48"minimum for the lowest character and 60" . for the highest character.Pictograms must be 6"in height at a minimum.The letter height should be - 787 5/8"-2"with ADA compliant text("0"is 55-110%the height of"I"). Braille and raised text only for room H-From ADA training-"sign that identify permanent spaces,room numbers or names,floor levels,and exits . d Characters and Braille" • ..4 Signs over door and over the 60"maximum height 1 A I Pictograms too small at 3"instead of the 6"minimum Town Hall- Detention Facilities PD The initial holding and fingerprint area in the PD has a bench with seat height that 403,903 Medium 4 Out High Regrade the flooring so the maximum slope is 5%.Could make bench height compliant if layer of l 170 MacGregor Ave. measures 19''A"-20"which is over then 19"maximum.There is a drain in the northeast flooring adding to make seat height 19"maximum. I corner of the room that creates a slope and cross slope that measures 8.75%-9.63% 788 which is over the 2%maximum for clear floor space and 5%maximum for running slope. V 1 Town Hall- Detention Facilities PD The south holding cell has ADA compliant turn around space unlike the north cell.The 807.2 Medium 4 Out High Replace the bench seat so the seat height is 19"maximum.The toilet seat height needs to be 17-19" • 170 MacGregor Ave. bench in the room has a seat height of 19 1"which is over the 19"maximum.The toilet in height and 16-18"from the sidewall to the toilet centerline.Flush controls should be to the open "l' • is not compliant with a seat height of 15 A"with the flush control located in the middle side of the toilet.The requirement of an ADA cell is contingent on the direction from the Attorney 789 above the toilet and the toilet located 15 X"from the side wall. General. Town Hall- Detention Facilities PD The north holding cell is not ADA compliant The turnaround space is 57"wide which is 807.2 High 4 None None The south cell is closer to compliance with one ADA compliant cell being the minimum.This is 170 MacGregor Ave. less than the 60"minimum.The bench in the room has a seat height of 1900"which is contingent on the Attorney General's direction for this issue. over the 19"maximum The toilet is not compliant with a seat height of 13 00"which is 790 under the 17"min and the flush control is located in the middle of the wall above the toilet and the toilet located 21"from the side wall. Town Hall- Controls Board room lobby The exterior ADA door opener button for the exterior door of the board room lobby 309.2 High 2 Out Medium Regrade concrete clear floor space for the button so the slope is less than 2%in any direction.:' 170 MacGregor Ave. entrance vestibule does not have compliant clear floor space.The cross slope due to the ramp is 2.3%which is over the 2%maximum. 791 Town Hall- Controls Public Restrooms The ADA door opener button located at the bottom of the ramp in the publicrestrooms 309.2 Medium 2 In Low Move the button to a location that has compliant clear floor space. 170 MacGregor Ave. area has a clear floor space with a cross slope of 2.3%which is over the 2%maximum. 792 Town Hall- Controls Admin Lobby Entry East The exterior ADA door button for the exterior door to the east vestibule of the 309.2 Medium 2 In and Medium Move shoe brush so the ADA door button has clear floor space of30"with the button located in the 170 MacGregor Ave. administration lobby is not compliant.The clear floor space extends 2"to the left of the Out middle of the width.Regrade the concrete so the slope is less than 2%in any direction. / button due to a shoe brush and has 30+"to the right.The clear floor space has a slope of - 793 1.9%and a cross slope of 2.5%. Town Hall- Water Fountains Public Restrooms The right,wheelchair,water fountain has a water flow height of 3%" 602.6 Low 4 In Low Adjust the spout so the water flow height is 4"minimum. 170 MacGregor Ave. - 794 Town Hall- Water Fountains 2nd floor hallway The water fountain by dispatch on the 2nd floor does not have ADA complaint knee and 602.2,602.5,602.6, Medium 4 Out High Replace with a wheelchair and standing water fountain combo that are ADA compliant. 170 MacGregor Ave. toe clearances.The spout is 12 Y.."from the rear support which is less than the 15" 602.7 minimum.The water flow is 6 Y."from the front edge which is over the 5"maximum 795 There is not a wheelchair water fountain nearby. Town Hall- Water Fountains 2nd floor hallway The water fountain by dispatch on the 2nd floor does not have ADA complaint knee and 602.2,602.4,602.6, Medium 4 Out High Replace with a wheelchair and standing water fountain combo that are ADA compliant. . 170 MacGregor Ave. toe clearances.The water flow is 8'4"from the front edge which is over the 5" 602.7 maximum.The spout height of 44''A"which is over the 43"maximum.The spout is 12 Y." 796 from the rear support which is less than the 15"minimum.There is not a wheelchair water fountain nearby. Town Hall- Restrooms Women's Public The women's public restroom entry door closes too quickly at 3.25 seconds and requires 404.28,404.2.9 High 2 In Low Adjust door closer so the door closes from a 90°to 12°position in 5 seconds minimum and requires 170 MacGregor Ave. 16 pounds of force to operate less than 5 pounds of force to operate. ' 1,. 797 Town Hall- Restrooms Women's Public The brackets for the counter in the women's public restroom are metal and unprotected 606.5 Low 3 In Low Add protection to the counter brackets. -= ! 170 MacGregor Ave. where wheelchair users could hit knees on them. . 798 Town Hall- Restrooms Women's Public The women's public restroom has 7 stalls and no ambulatory stall. 213.31 Medium 3 Out Medium Modify one stall to be an ambulatory stall. NMI 170 MacGregor Ave. 799 Town Hall- Restrooms Women's Public The ADA compartment toilet in the women's public restroom is 1814"from the side wall 604.2,604.6 Medium 3 In or High Remount toilet or add''A"of wall to make the toilet 16-18"from thesidewall.Adjust the auto flush so .. r 170 MacGregor Ave. which is outside of the 16-18"range for an ADA compartment stall.The flush controls Out the manual button is on the open side. are auto but the manual button is on the closed side. 800 ca Town Hall- Restrooms Men's Public The men's public restroom entry door is recessed 10"and has 8''4"of maneuvering 404.2 4,404.2.8, High 2 In or High The maneuvering clearance for a recessed door is 18"on the pull side.This is not possible due to theli 170 MacGregor Ave. clearance on the pull side of the door.The door closes too quickly at 3 seconds which is 404.29 Out walls and therefore an ADA door opener should be added for the door.The door closer should be under the 5 second minimum.The door requires 15 pounds of force to operate which is adjusted in the meantime so the door closes from a 90°to 12°position in 5 seconds minimum and 801 over the 5 pound maximum. requires less than 5 pounds of force to operate y' Town Hall- Restrooms Men's Public The men's public restroom has 3 stalls and 3 urinals for a total of 6,and no ambulatory 213.3.1 Medium 3 Out Medium Modify one stall to be an ambulatory stall. 1' wall 170 MacGregor Ave. stall. 802 J Town Hall- Restrooms Men's Public The left-hand dryer in the men's public restroom do not have compliant clear floor space.309.2 Medium 3 In or Medium Cut a hole in the left side of the counter for a trashcan to be placed underneath the counter The ,y 170 MacGregor Ave. The hand dryer is partially blocked by the trashcan creating a non-compliant situation. Out right-hand dryer is compliant but has the hand dryer located in the right half of the clear floor space li 1 width. -- 803 Town Hall- Restrooms Men's Public The mirror by the entry of the men's public restroom does not have enough clear floor 603.3 Low 3 In or Medium Move the trashcan to another location. 170 MacGregor Ave. space depth due to the trashcan. Out 804 Town Hall- Restrooms Men's Public The ADA compartment toilet does not have the flush controls mounted to the open side. 604.6 Low 3 In Low Remount flush controls so manual push button is on the open side. 170 MacGregor Ave. The controls are auto,but the manual button is not to the open side. 805 Town Hall- Restrooms Men's Public The toilet paper dispenser in the men's ADA stall needs to be remounted to an ADA 604.7 Low 3 In Low Remount toilet paper dispenser so that the distance is ADA compliant. 170 MacGregor Ave. compliant distance from the toilet.The current distance is 5 M"and 16"which are outside of the 7-9"range. 806 Town Hall- Restrooms Executive Women's The entry door to the executive women's restroom closes too quickly at 3.5 seconds. 404.2.8 Low 2 In Low Adjust closer so the door closes from a 90°to12°position in 5 seconds minimum and requires less 170 MacGregor Ave. than 5 pounds of force to operate. -. 807 Town Hall- Restrooms Executive Women's The drain pipes in the women's executive restroom are unprotected. 606.5 Medium 3 In Low Add drain pipe protection. 170 MacGregor Ave. '11i l,�' 808 .11 Town Hall- Restrooms Executive Women's The executive women's restroom has hand towel dispenser that is manual and requires 309.4 Low 3 In Low Replace with an auto dispensing paper towel holder. 170 MacGregor Ave. grasping of the towels to operate. 809 'lb' Town Hall- Restrooms Executive Women's The executive women's ADA stall was measured to have 59 K"of width which is less than 604.8.1.1 Low 3 In or Medium The stall width should be 60"minimum. 170 MacGregor Ave. the 60"minimum. Out r".. 810 O Town Hall- Restrooms Executive Women's The toilet in the ADA compartment of the women's executive restroom is mounted 604.2 Low 3 In Low Remount toilet so it is 16-18"away from the sidewall. 1�� 170 MacGregor Ave. crooked with the rear 1936"from the side wall and the front 17"from the side wall !, 811 Town Hall- Restrooms Executive Men's The entry to the men's executive restroom in not compliant.The width is 26%"which is 404.23,404.2.4, Medium 2 In and High The closer needs to be adjusted so the door closes from a 90'to 12'position in 5 seconds minimum gm 8 170 MacGregor Ave. less than the 32"minimum.There is a privacy wall present that is 41''A"from the entry 404.28,404.2.9 Out and requires less than 5 pounds of force to operate.Add an ADA door opener since movingthe t door and reduces the maneuvering clearance depth below the 48"minimum.The door privacy wall is not feasible.The door width should be widened to a minimum 32" 011 812 closes in 2.5 seconds and requires 7 pounds of force I 4i Town Hall- Restrooms Executive Men's The men's executive restroom has a cabinet for the base of the counter.There is no 606.2,606.5 Medium 3 In or Medium Replace cabinet/counter with an ADA compliant counter.Add pipe insulation to drain pipes. 170 MacGregor Ave. compliant toe or knee space.The drain pipes are unprotected. Out 813 Town Hall- Restrooms Executive Men's The men's executive restroom has a hand dryer with clear floor space of 22%"wide 309.2 Low 3 In Low The hand dryer is blocked by the trashcan and chair.Remove chair from restroom area. 170 MacGregor Ave. which is less than the 30"minimum. Mir-i a� 814 L— Town Hall- Restrooms Executive Men's The men's executive restroom does not have an ADA compliant stall. 604.8 Medium 3 Out High Reconfigure so there is an ADA complaint stall. 170 MacGregor Ave. 815 Town Hall- Restrooms Executive Men's The men's executive restroom does not have an ADA compliant urinal.The urinal has a 605.2 Medium 3 Out High Replace with an ADA complaint urinal mounted at the proper height. II- 170 MacGregor Ave. rirn height of 23%"which is over the 17"maximum.The depth of the out face is 12 X" which is less than the 133"minimum 816 Town Hall- Restrooms Administration The administration conference room restroom entry door is not ADA compliant.The 404.2.3,404.2.4, Low 3 Out High The restroom will have to be reconfigured to make it ADA compliant. 170 MacGregor Ave. width of the door is 27"which is less than the 32"minimum.The maneuvering clearance 404.2.8,404.2.9 has only 4"of width which is less than the 18"minimum.The door knob is round and 817 requires grasping to operate and there is no kickplate. i Town Hall- Restrooms Women's-2nd floor The 2nd floor north women's restroom(Women's#1)entry door is not compliant.The 404.23,404.2.4, Low 2 In and High The closer needs to be adjusted so the door closes from a 90'to 12'position in 5 seconds minimum 170 MacGregor Ave. north end of hallway width of the door is 28%"wide which is less than the 32"minimum.The maneuvering 404.28,404.2.9 Out and requires less than 5 pounds of force to operate.The door width should be widened to a clearance width is 11%"which is less than the 18"minimum.The door requires 6 pounds minimum 32".Add an ADA door opener if maneuvering clearance can't be made compliant(18"W x 818 of force to operate and closes in 1.9 seconds. 60"D for the pull side). Town Hall- Restrooms Women's-2nd floor The 2nd floor north women's restroom(Women's#1)counter has supports that are 606.5 Low 3 In Low Add protections to the drain pipes and counter supports. 170 MacGregor Ave. north end of hallway unprotected and located 4"from the front of the counter.The pipes are unprotected as well. F 819 Town Hall- Restrooms Women's-2nd floor The towel dispenser in the women's restroom#1 has the clear floor space blocked by a 309.2 Low 3 In Low Move the trashcan to a spot that doesn't block any clear floor or maneuvering spaces. Ertg 170 MacGregor Ave. north end of hallway trashcan mounted on the wall. I. 820 16 Town Hall- Restrooms Women's-2nd floor The women's#1 restroom does not have an ADA compliant stall. 604.8 High 3 Out Medium Reconfigure so there is an ADA complaint stall. 170 MacGregor Ave. north end of hallway 821 Town Hall- Restrooms Women's-2nd floor The 2nd floor south women's restroom(Women's#2)entry door is not compliant.The 404.23,404.2.4, Medium 2 In Medium The closer needs to be adjusted so the door closes from a 90'to 12'position in 5 seconds minimum 170 MacGregor Ave. south end of hallway width of the door is 29"wide which is less than the 32"minimum.There is a second 404.26,404.2.8, and requires less than 5 pounds of force to operate.The interior doorway and privacy wall should be doorway 25%"from the entry door which is less than the 48"minimum.The second 404.29 removed due to the non-compliant issues as well as the wall is not needed.Without the wall,there 822 doorway is 26%"wide which is less than the 32"minimum.The maneuvering clearance would be adequate maneuvering clearance width.The door width should be widened to a minimum width is 10)6"which is less than the 18"minimum.The door requires 10 pounds of force 32" to operate and closes in 2.7 seconds. Town Hall- Restrooms Women's-2nd floor The 2nd floor south women's restroom(Women's#2)has a cabinet for the base of the 606.2,606.3,606.5 Medium 3 In or High Replace cabinet/counter with an ADA compliant counter.Add pipe insulation to drain pipes. Mal 170 MacGregor Ave. south end of hallway counter.There is no compliant toe or knee space and the counter height is 36"which is Out over the 34"maximum The drain pipes are unprotected. 823 Town Hall- Restrooms Women's-2nd floor The sinks and middle soap dispenser do not have enough clear floor space depth due to 309.2,606.2 Medium 3 Out Medium Replace cabinet with counter and these issues should be resolved with clear floor space extending 170 MacGregor Ave. south end of hallway the cabinet and stall walls.The paper towel dispenser also has limited clear floor space under the counter. _ width at 29 IS"where the width reduces due to the wall. 824 Town Hall- Restrooms Women's-2nd floor The women's#2 restroom does not have an ADA compliant stall. 604.8 Medium 3 Out High Reconfigure so there is an ADA complaint stall. 170 MacGregor Ave. south end of hallway 825 Town Hall- Restrooms Men's-2nd floor The 2nd floor men's restroom(Men's#2)entry door is not compliant.The width of the 404.2.3,404.2.4, Medium 2 In and High The closer needs to be adjusted so the door closes from a 90'to 12'position in 5 seconds minimum 170 MacGregor Ave. door is 28%"wide which is less than the 32"minimum.There is a second open doorway 404.2.6,404.2.8, Out and requires less than 5 pounds of force to operate.The interior doorway and privacy wall should be 17"from the entry door which is less than the 48"minimum.The second doorway is 28" 404.2.9 removed due to the non-compliant issues as well as the wall is not needed.Without the wall,there ' 826 wide which is less than the 32"minimum.The maneuvering clearance width is 17"which would be adequate maneuvering clearance width but not enough depth.The door width should be is less than the 18"minimum with 44%"of depth which is less than 60".The door widened to a minimum 32". requires 11 pounds of force to operate and closes in 1.5 seconds.There is also no kickplate present. Town Hall- Restrooms Men's-2nd floor The 2nd floor men's restroom(Men's#2)counter is not ADA compliant.There is an 606.2,606.3,606.5 Medium 3 In Medium Replace middle support with one that creates the proper knee and toe clearances as well as the !! I 170 MacGregor Ave. unprotected middle support located in the middle of the counter and is 4%"from the proper clear floor space. �gi. !e•, ( ( 4 front.This supports creates clear floor space width of 24%"and 27%"for the sinks 827 which is less than the 30"minimum.The drain pipes are unprotected. Town Hall- Restrooms Men's-2nd floor The clear floor space for the sinks and middle soap dispenser are not compliant due to 606.2,606.4 Medium 3 In Medium Remove middle support and replace with an angle bracket that allows for the proper clear floor space -I ' 170 MacGregor Ave. the middle support piece of the counter with widths of 24%"and 27'A"which are less depth and width.Replace faucets with Ada compliant ones. than the 30"minimum.The sinks have round knobs that require grasping to operate. 828 Town Hall- Restrooms Men's-2nd floor The men's 82 restroom does not have an ADA compliant stall. 604.8 Medium 3 Out High Reconfigure so there is an ADA complaint stall. 170 MacGregor Ave. 829 I. Town Hall- Restrooms Men's-2nd floor The men's 82restroom urinals have a rim height of 205/8"which is over the 17" 605.2 Medium 3 Out Medium Replace one of the urinals with an ADA compliant one. 170 MacGregor Ave. maximum. 830 O'Connor Pavilion- Parking See Hydroplant Parking See Hydroplant Parking Sections 502 See Hydroplant Parking Sections 1700 Fish Hatchery Road Sections 831 O'Connor Pavilion- Accessible Route Pavilion Area There is no ADA compliant accessible route connecting the restroom,pavilion,food 402 High 2 Out High Add an ADA compliant route that is 36"wide and made out of concrete or another firm and stable 1700 Fish Hatchery Road serving areas,and the ceremony sites.The ground is gravel and is not considered firm or product that connects the ceremony sites to the reception areas including the restrooms,pavilion, ... stable.There is a steep hill seperating the ceremony sites from the reception areas.The and parking. -- 832 area is also a drainage pathway during rain events. v- O'Connor Pavilion Signage Men's and Women's The slope for the restroom signs are 2.3-2.6%which is over the 2%maximum. 703.4 Medium Low Out High Redo the concrete pad on the outside of the restrooms so that the slope is less than 2%in any M 1700 Fish Hatchery Road Restrooms direction. 1' 833 c � •��� O'Connor Pavilion- Restroom-Entry Women's The entry for the women's restroom is not compliant.The doorway height is 79"and the 404.23,404.2.8, Low Low Out High Replace doorway with one that has a height of 80"and the closer is 78"minimum.Adjust the closer 1700 Fish Hatchery Road closer is at 773/4"which are less than the 80"and 78"minimum.The door closes in 2.2 404.2 9 so the door closes in 5 seconds and requires no more than 5 pounds of force to operate. seconds and requires 7.5 pounds of force to operate which are not compliant. 834 A. O'Connor Pavilion- Restrooms Men's The entry for the men's restroom is not compliant.The doorway height is 79"and the 404.2.3,404.2.8, Low Low Out High Replace doorway with one that has a height of 80"and the closer is 78"minimum.Adjust the closer 1700 Fish Hatchery Road closer is at 773/4"which are less than the 80"and 78"minimum.The door closes in 2.2 404.2.9 so the door closes in 5 seconds and requires no more than 5 pounds of force to operate. and requires 7.5 pounds of force to operate which are not compliant. 835 secondsy O'Connor Pavilion- Restrooms Hand Washing station The base for the hand washing station is not compliant with onity 81/2"of depth under 606.2 High Med In Med Replace hand washing sink base with one that is ADA complaint. - -- 1700 Fish Hatchery Road the counter from the front for proper knee clearance I 836 • O'Connor Pavilion- Restrooms Men's and Women's The coat hooks on the ADA stall doors are mounted to high at 64"+and not ADA 603.4 Low Low In Low Lower the coat hooks so they are a maximum of 48"from the ground. I 1700 Fish Hatchery Road Restrooms complaint. 837 O'Connor Pavilion- Restrooms Women's The women's restroom ADA stall is not complaint.The door is 5"from the side wall and 604.8 Medium Med Out High Remount door so it is a maximum of 4"from the side wall.Replace hinges so door is self closing and 1700 Fish Hatchery Road does not self clode.There are no ADA door handles. add ADA pull handles to both sides of the door. 838 O'Connor Pavilion- Restrooms Women's The toilet is mounted 191/2"from the side wall which is over the 19"maximum. 604.2 Medium Low Out High Need to reposition stall walls or toilet so the toilet is 17-19"from the side wall. 1700 Fish Hatchery Road 839 O'Connor Pavilion- Restrooms Women's The ADA grab bars are not compliant The height of the rear bar is 37"which is over the 609.3,609.4 Medium Med In Med Remount grab bars so the height is 33-36".There needs to be 12"between the grab bar and any 1700 Fish Hatchery Road 36"maximum.The side grab bar has a height of 37"and has the toilet paper dispenser 6" objects above it above it. 840 O'Connor Pavilion- Restrooms Men's The men's restroom ADA stall is not complaint The door is 51/4"from the side wall and 604.8 Medium Med Out High Remount door so it is a maximum of 4"from the side wall.Replace hinges so door is self closing and 1700 Fish Hatchery Road does not self clode.There are no ADA door handles. add ADA pull handles to both sides of the door. 841 O'Connor Pavilion- Restrooms Men's The toilet is mounted 191/2"from the side wall which is over the 19"maximum. 604.2 Medium Low Out High Need to reposition stall walls or toilet so the toilet is 17-19"from the side wall. 1700 Fish Hatchery Road 842 O'Connor Pavilion- Restrooms Men's The urinal in the men's restroom is not ADA complaint.The depth of the urinal stall is 26 605 Medium Low Out High Replace urinal with an ADA compliant one and adjust stall so the depth is 48"minimum. 1700 Fish Hatchery Road 1/4"to 411/4"which is less than the 48"minimum.The depth of the outer face of the urinal is 101/2"which is less than the 131/2"minimum. 843 O'Connor Pavilion- Restrooms Men's The ADA grab bars are not compliant The height of the rear bar is 361/2"which is over 609.3,609.4 Medium Med In Med Remount grab bars so the height is 33-36".There needs to be 12"between the grab bar and any ' j 1700 Fish Hatchery Road the 36"maximum and has the toilet paper dispenser 6"above it.The side grab bar has a objects above it height of 37 3/4". 844 O'Connor Pavilion- Restrooms Men's The toilet paper dispenser in the ADA stall is not ADA complaint.The distance to the 604.7 High High In Low Remount toilet paper dispenser so that on of the openings is in the 7-9"range.Make the other one 1700 Fish Hatchery Road dispenser from the toilet is 24"and 33"which is over the 9"maximum. less than 7".Insure there is 12"between grab bar and dispenser. 845 O'Connor Pavilion- Serving Tables Serving Tables The serving tables are not ADA complaint.The ground surface has slopes and cross slops 904.4 High Med In/Out Med Redo serving tables so the ground surface has a maximum slope and cross slope of 2%There need to 1700 Fish Hatchery Road over the maximums.There is not adequate knee clearances. be knee clearances with 27"of height under serving tables that have a maximum counter height of 36".The depth under the surface should be 17-25". 846 2020 Town of Estes Park ADA Audit Summary Report Severity analysis rating: Created by:Casey PrisMorton 3.toss— whim has no sneer on the WSW or the WHY to=err SOPP pograms and services*.aeon..in whiM there is orris a minor derWon from the requirements or the code. Buildirw Area/W.0m gone/Section P.mwmphm.rt Element Compliance Section Mtge Measr.Mlie ggsrpssseg gyst yrmsrsgsny VIsItor[enter Parking Lot Single Access Space by west Has a mash...one of 5.2.which is over the limlt of 2.502 High Pegrarle parking surface so Mar slope in any direction is< . Pedestrian Bridge rn any direction %O. . • • . • Visitor Center Parking Lot Past side access parking space pair Have a 4.5%slope In the left space and 5..in the right 502 4 High Pegrade parking surface so that slope In any direction is< North space along...Mr the aisle which is over the lima of.6 in any direction jr1111111111111.,_ 4111.111%111102", c1.1--, Visitor Center Parking Lot East sideweess parking space palr Have a slope of 5.in the left space and In the right 502 4 High Pegrade parking surface so that slope In any direction is< South space along svrth 2 116 Mr the aisle which IS over the lima • or 29.1 in any direction 'V A • - - Visitor Center Parking Lot The group of 4 access spaces on NW LetHeast)aisle has a slope of 2.296 along with 2..in the 502 4 Medium Pegrade parking surface so that slope In any direction is< of building right...space which mover the hmit ol 2.in am/ -— directions --. Visitor Center Parking Lot Single A...55ga.by west missing a Drosss We ossssrmusvouurtosso*srsSo,t Medium Ipnos:11,selgyne i‘net,e,rbs,aerisopn.aciesy.mtbzitafthaeocesbottsolb.,111ohn.a Pedestrian Bridge only markings on pavement surface sign is at least 601 ahove the ground _ Visitor Center Lot aSt side access pariong space pair Left space missing a sign wth the inWmational symbol of S02. Medium Install sign with inWmational symbol of accessibility on a — North accessibility,only markings on pavement surface PoW at every accessible space so that the bottom of the sign is at least 60"Wove Me ground Visitor Center ParkIng Lot East Me access parking space pair mIssIng a sign with the InternatIonal symbol of access.111,602 6 Medium 1.011 slgn with international symbol of accessIMIty on a Iv-n9.--. :•", , • Sou. only markings on paveine.surram post at eve,accessible space so that the bottom of the ....-a,.91% - '.% sign Is at lea%MC above the ground 3% Visitor Center parLing Lut The group of 0 access spaces on NW Only one access space has a%an accessible"sign mounted 502 6 Medium Install"Van Accessible"signs on posts with international of building on a post,this sIgn%faded ancl unreadable symbol of accessibility at every access space that an be fe considered van accessible 11/0" a • .- ...- Visitor Center Parklng Lot/AccessIble Po. Exterior of building Sections of the access route cross..ramps from the 403 3 Hlgh Region.access route to 656 maximum runnIng slope Parking areas end cause the running SiOPe%Me access and/or add level landing areas et the top of each curb route to be steeper...e.6 Iiint Cu.ramp by EVHA ramp ai least 36,IdecreatIng a level access route door measured at 12 4%,Curb ramp between the EVHA 9 door and the north entrance was measured at 72%,and ' -- . .curb rallIP bli the 4s a...7••••6r555 w. measured be.een 6,7%-7.7% . . . . VisiMr CeMeL Parking Lot/AccessIble Po. Exterior of building Sections of the access route cross..ramps from the 403 3 HIgh Degrade access route.296 inanImum cross slope and/or 3' I --3 7 7,;..- h'• Parking areas und cause the cross slope or the access route add level landing areas at the top or each cu.ramp et — ' to be steeper than the 2%II.Curb ramp by.port., least 36"wide creating a level access route , .../creates a cross slope or 8 MC curb ramp by EVHA door - m- -.— la creates a cross slope of 7,096,ancl the curb ramps by the ..... ree_,..- group or 4 access spaces cream cross slopes of 7 4.easO and (wes% . . —•444$1111111111EL-. .... .'-- - .:..-... . . . Pr I..1 - . '. - ior • fr - . Visitor Center ParkIng Lot ...naps on East Side Curia ramps on.e east side access parklng space palrs 406 1,..6.2 High Remade curb ramps so that the ramp Is no steeper than \ were both measured at 8.7%whch is overtime 03%limit 8 03% 11 IIII0 Visitor Center ParkIng Lot East Side Access Same P.N.. Does not have a level 36.wide level landlng space at the 406 4 High liegrade landing area at top of ramp to level and remove top or the curb ramp,grass 840"away with angled edge grossiudd pavement so that the Walth is 36" that Prn.landing area width to less than 36"wide and Is .not level,measured at 6.3% _ ......,,. • ' . ' • . ._ Visitor Center Entrances 5550350555555 No signage at non.access entrances,the No.and South 216 6 High Install SI..at the North and South entrances with . k . 4 entra ,wtth directions to the accessible entrance, %mations to the Afterhours entrance I _ Afterhours entrance ...13 . .. • ----- _ Visitor Center EntranCe• North and South Lobby Entrances Thntere Is ndo mandeuve,ring clearance on the pull side of any 404 2A Low Install automatic openers at all entrances '•'., double door configuration Only the VI ,- I- E2 i afte..9 right door has an automatic opener with push button Afterbour cl o h I %Lot •- . does not make It the shortest trip from the parking areas • . __.... . vnAtor center ,ttrancec Afterhours Entrance The left door of the afterhorsento cl.es too Aulckly 404 2.8 Medium Adjust closers so dor closes from 901to 12.p.Ition In at from a 901 to 12°position,'Treasured at 3.5 seconds which least 5 seconds is under the 5 second limit 15 iii; .11111 Visitor Center 9A,AmAces South River Doors The right door closer.°quickly from a 001to Ironton,000 2 8 Medium Adjust closers so door closes from 901 to 12°position in at measured at 3.5 settonds which is under the 5 second Almit least 5 seconds 1 I . 49 L.`g • 1.6 111 Vnitor Center Entrances Ettrances Edges dross are not secured 302 2 Medium Securely attach rug edges to flooring I- g ii 17 — 1•1, • . w _ II .- o Visitor Center Accessible Route-inteor Afterhours Area Cross slope was measured at 2 216 outside of the family .3 3 Low Begrade floor so maximum cross slope is 292 restroorns for approttmately 6'of the access route,Emit Is 18 Medium Belo..Moak Box to area where It does not protrude "1 e'd'nce n''''Vttitor Center Afterhours Area Public Bestrooms Ent,doors Ldepak Box looted on wall between restroom dors 307 2 , protrudes 7"into acms route and the bottom edge is 08 into accessible route 151from the floor 19 It p Visitor Center Afterhours area Near ento doors Bulletin board by main entrance has pamphlet holder with 307 2,307 0 Low Tnm ends to 01 ends that protrude 4 A"into the accessible route and is * above,but below 801 20 ' f lir Visitor Center Main Lobby Gallery Petal!Wall Calendar holder on gallery wall ProttnCes 6'O. 307 2 Low Move olendar holder down so bottom edge is a maximum ..--....7._ accessible route and is looted 31"from the floor of,above floor -.. 1-'Aq' -9.,Zttl --1 21 Visitor-Center Elevator interior buttons The intenor buttons are looted out of reach with Me .8 0 6,007 6 1 nigh Lower buttons hettht to a maximum of Or kill emergency call button Wand the cancel oll button 52 le above the floor 22 Vlsitor Center Elevator MLEB0.19tME BatanS are located 9-13"from.comer of the elevator 408 4.6 Low Move buttons to center of side wall instead of centered on a wall 23 . • • Visitor Center Elevator Aigna,e Sign on doorrams at the floor levels are located with .7 2 3,008 2 3 Low Lower onage so highest character baseline is 601 highest character basellne at BO,which Is over the 601 mattmum loit 20 A Visitor Center Main Lobby Display racks The menu/newspaper display is looted 291 from the 403 5.1 ben.seating m front of Me windows which is less than HO Peloote display so aisles are a minimum AIM"wlde •.: ._. ' , l Art . the 361 minimum i..1%.- 25 i4°' y,i‘widemer Main Lobby Display raclis "delve°displays on the south side of the main area have a 403 5.1 High Relocate display so aisles are a minimum of 36"wide column between them voff not enough clearance for an aisle . 26 Visitor Center Main Lobby Fire alarm Fire alarm pull on south wall is blocked hy trash dn 305 3 Hid Trash can and make sure there is a 30,18"clear space fd i a forward or parallel approach 22 Visitor Center Main Lobby Ambassador Counter The cashier counter has 83,clear Ildr space that extends 306 2.2,306 2 3 Medium Peconflgure counter so that ff ere is clear space for a under the counter which is less than the,minimum forward approach of 123, • i_,_—a' • iv._ Addl..,the counter ff 46)52 wide a.has a staff L - wallevay next to it which does not allow for a 48"mindum ii 28 Parallel approach If.e staff walkway is being used Visitor Center Public Restrooms Men's Front approach of men's door on pull side only has 6 4"of 404 2 4 medium Add automatic door openers maneuvering clearance,lesdhan the 18"minimum,when the unnal closest to ff e dooms being used.Same issue on .= the women's side,howeved is a lavatory instead of a 29 urinal and ff e lavatory edge is 18"from the edge of the i ' door swing 11' Visitor Center Public Pestroorns Me5' Men,door requires 2 Lbs.of force to open which Is over 404 2.9 High Adjust closer or add automatic opener ffe maximum 30 Visitor Center Public Restrooms Entry Doors Women's ond Men's doors close too quickly from a 90.to 404 2 8 High Adjust closer or add automatic opener so door takes at 12.•position least 5 seconds 31 1-• Visitor Center Public Pestroorns Family Pestroorn The family restr.m lavatory has 26 ad of clearance from 306 3.3 liel.lum Alter or replace lavatory so clearance to floor Is at least 27. •T.N. floor which is a 1.1e less than the,minimum -,-.. 32 Vi sitor Center Public Restrooms Family ReStrOOM The family regrown lavatory has pipes insulated to protect 606 5 ta High Add insulation so that bottom of lavatory a protected _ Ilk. againff contad,hut the bottom of the lavatory extends against conct below the edge and is unprotected • i i 33 Visitor Center Public Restroorns .o5.5 The access stall doors do not self close High Add self-closing hinges to access sMil d.rs 34 Visitor Center Public Restrooms women., The access stall doors do not self close 604 3 1.2 High Add self-closing hinges to access stall doors 35 Visitor Center Public Pestroorns Men's The access stall doors,.not have ADA compliant door 604 8.1.2 High Add ADA compliant door pulls to both sides of access stall handles acors ..,--- 36 3 visitor Center rublb Pestroorns Warne. The au:mists,doors,.not have ADA compliant door 604 8.1.1 111811 ..compllant door pulls to leent seles of access stall; handles Woes VIM.Center Public Restrooms Me. Men's access stall has a compartment area elepth of 521M.8 1.1 Ingh Reverse.door some to open out—may be issue slue Co outs.of the door swing when Is less Man the 561 stall door nett to access stall also opening oot nonenum 38 Veltor Center roam Ilestroorns women: Reverse.door sveIng to open out—may In Issue duet°.8.1.1 Me Reverse.door swIng to open opt-may be Issue due to stall door next to access stall also wen.out stall door next to access stall also wen.out 39 Motor Center Afternours Area Water Fountains The Mantling person water WuntamM811Muntain)has 601 Medium Adjust Winking...hmet so Mat Me moot os mra sues pout located at 37 le which Is below Me 381 38,131 above Me floor nonenum 00 2020 Town of Estes Park ADA Audit Summary Report Severity analysis rating: 1.1figb-A condition wit.significantly impedes or prohibits Me ability°idle public to access TOEP programs and services. 2.Moderate—A condition wit.affects Me ability of Me public to access TOEP programs and services in a minor way or a condition...only affects TOEP staff. Created by:Kasey McMorton 3.1.ow—A condition.icfl has no effect on Me ability of Me public to access TOEP programs and services or a condition in...Mere is only a minor deviation from Me requirements of Me code. Building Area/Location Zone/Section Non-compliant Element Compliance Section Seventy Corrective Measure Photo Estimated Cost Timeframe Tregent Park Restroom Exterior Entry Men's Restroom doors require more than the maximum force 404.2.9 High Add an automatic door opener allowed to open,measured at 10Lbs.for Women's ill.." 1 Tregent Park Restroom Exterior Entry Women's Restroom doors require more than the maximum force 404.2.9 High Add an automatic door opener allowed to open,measured at 14Lbs.for Men's IP 2 ll? Tregent Park Restroom Interior On Stall Doors Coat hooks are installed at a height of 58" 603.4 Low Re-install coat hooks at a height of 15-48" 3 Tregent Park Restroom Interior Women's Women's counter height was measured at 35" 606.3 High Alter counter so height is 34"of under with a compliant clearance from the floor 4 Tregent Park Restroom Interior Men's No pipe insulation underneath counters 606.5 High Add pipe insulation underneath counters to protect _,, against contact 3 5 6 Tregent Park Restroom Interior Women's No pipe insulation underneath counters 606.5 High Add pipe insulation underneath counters to protect against contact --41 I V a..., Tregent Park Restroom Interior Women's Toilet centerline is 22 X"from side wall 604.2 High Move or replace toilet so that the centerline is 16-18"from side wall 7 Tregent Park Restroom Interior Women's Toilet centerline is 22 X"from side wall 605.2 High Move or replace toilet so that the centerline is 16-18"from side wall 8 Tregent Park Restroom Interior Men's Width of access stalls were measure at 9535"on the men's 604.3.1 High Replace stone partitions with HDPE partitions that are side reconfigured to allow for the ADA-compliant width of the access stall 9 Tregent Park Restroom Interior Women's Width of access stalls were measure at 45"on the 604.3.1 High Replace stone partitions with HDPE partitions that are women's side and 45 k"on the men's side reconfigured to allow for the ADA-compliant width of the access stall 10 Tregent Park Restroom Interior Men's Toilet height is 20" 604.4 High Adjust or replace toilet so height is 17-19". 11 Tregent Park Restroom Interior Women's Toilet height is 20" 605.4 High Adjust or replace toilet so height is 17-19". 12 Tregent Park Restroom Interior Men's and Women's Clearance between grab bar and toilet paper dispenser 609.4 N/A If built before 3/15/2012,nothing needs to be done was measured at 116"on the women's side and 9%"on the Men's side 13 Tregent Park Restroom Interior Women's Women's access stall does not have a rear grab bar 604.5 High Add a rear grab bar that is 36"long at the compliant height and position 14 Tregent Park Restroom Interior Women's Women's access stall flush control required 8Lbs to 605.4 Medium Adjust or replace Flush control so less than SLbs of force is operate required to operate 15 Tregent Park Restroom Interior Men's and Women's Toilet Paper dispenser is mounted to close to toilet 604.7 N/A If built before 3/15/2012,nothing needs to be done 16 Tregent Park Restroom Interior Women's Access stall doors opening in are blocked from opening the 604.8.1.2 High Reconfigure access stall doors to open out full 90° 17 Tregent Park Restroom Interior Men's Access stall doors opening in are blocked from opening the 604.8.1.3 High Reconfigure access stall doors to open out full 90° 18 Tregent Park Restroom Interior Women's Not enough clear depth for a latch approach to the access 604.8.1.2 High Reconfigure access stall doors to open out stall doors 19 Tregent Park Restroom Interior Men's Not enough clear depth for a latch approach to the access 604.8.1.3 High Reconfigure access stall doors to open out. stall doors 20 Tregent Park Restroom Interior Men's Men's access stall door is not self-closing 604.8.1.2 Medium Install self-closing hinges on Men's access stall door 21 Tregent Park Restroom Interior Men's There are no door pulls on the access stall doors 604.8.1.2 High Install ADA-compliant pulls on both sides on the access stall doors 22 Tregent Park Restroom Interior Women's There are no door pulls on the access stall doors 604.8.1.2 High Install ADA-compliant pulls on both sides on the access stall doors 23 2020 Town of Estes Park ADA Audit Summary Report Severity analysis rating: ',Ugh-A condition which significantly impedes or prohibits the ability of the public to access TOEP programs and services. 2.Moderate—A condilion which eh.Me ability of the public to access TOEP programs and services in a minor way or a condilion which only affects TOEP staff. Created by:Kasey McMorton 3.Low—A condition which has no effect on Me ability of Me public to access TOEP programs and services or a condition in which Mere is only a minor deviation from Me requirements of Me code. Building Area/Location Zone/Section Non-compliant Element Compliance Section Severity Corrective Measure ph,,,, Estimated Cost Timeframe Riverside Restroom Exterior Signage No signage with directions to accessible restrooms 216.8 High Install signage with directions to accessible restrooms 0 .__... Riverside Restroom Entry-Exterior Women's Area on outside of entrance door to women's toilet room 404.2.4 High Regrade area so slope is<2% It too steep,measured at 2.6%slope 2 Riverside Restroom Entry-Exterior Women's Threshold to women's restroom is too tall where 1 Sr 404.2.5;303.2 High Regrade area so threshold is a maximum of%.vertical angle up to a 34"vertical threshold with the top le beveled height and top 34"are beveled OR SS"vertical height with top 3b"beveled 3 Riverside Restroom Entry-Interior Men's Pull handles on inside of doors are mounted too high at 47-404.2.7 Medium Re-mount pull handles so the height is 34-48" 53" . . 4 Riverside Restroom Entry-Interior Women's Pull handles on inside of doors are mounted too high at 47-404.2.8 Medium Re-mount pull handles so the height is 34-48" 53" 5 Riverside Restroom Entry Doors Men's Restroom doors require more than the maximum force 404.2.9 High Add automatic door openers allowed to open,measured at 12Lbs.for Men's 6 Riverside Restroom Entry Doors Women's Restroom doors require more than the maximum force 404.2.9 High Add automatic door openers allowed to open,measured at 12Lbs.for Women's 7 Riverside Restroom Entry Doors Women's Women's entrance door closes too quickly from a 90°to 404.2.8 High Add an automatic door opener 12°position 8 Riverside Restroom Interior Women's The mirrors on the women's side are mounted too high at 603.3 Low Mirrors should be remounted to a proper height of 40" 43 34" maximum for the bottom edge of the reflecting surface 9 Riverside Restroom Interior Men's The coat hooks are mounted too high,measured at 62"in 603.4 Medium Re-mount coat hooks at a height of 15-48" the women's and 61"In the men's 10 Riverside Restroom Interior Women's The coat hooks are mounted too high,measured at 62"in 603.4 Medium Re-mount coat hooks at a height of 15-48" the women's and 61"In the men's 11 Riverside Restroom Interior Men's The clearance height for the counter in the Men's side is 306.3.3 High Adjust counter so that clearance height is a minimum of too low at 26 34" 27" 12 Riverside Restroom Interior Men's There is no pipe insulation under the counters in restroom 306.3.3 High Add pipe insulation -- 13 Riverside Restroom Interior Women's There is no pipe insulation under the counters in restroom 306.3.3 High Add pipe insulation ■ Alllia'... -- 14 Riverside Restroom Interior Men's Toilets are too far from side wall measured at 1915"in the 604.2 High Move toilets so that centerline is 16-18"from side walls 15 Riverside Restroom Interior Men's Toilets are too far from side wall measured at 21"in the 605.2 High Move toilets so that centerline is 16-18"from side walls 16 Riverside Restroom Interior Men's The access stalls in both restrooms are not wide enough, 604.3.1 High Reconfigure partition walls so that access stalls area measuring at 42"in the men's minimum of 60"wide 17 Riverside Restroom Interior Women's The access stalls in both restrooms are not wide enough, 604.3.1 High Reconfigure partition walls so that access stalls area measuring at 4114"In the women's minimum of 60"wide 18 Riverside Restroom Interior Women's Grab bars inrtalled in the access stall on the women's side 604.5.1;609.4 High Re-mount grab bar where the top gripping surface is 33- are ounted too low at 27"and do not extend far enough 36"from the floor and extends 54"from rear wall from the rear wall at 53" 19 Riverside Restroom Interior Men's Grab bars inrtalled in the access stall on the men's side are 604.5.1;609.5 High Re-mount grab bar where the top gripping surface is 33- ounted too low at2614"and do not extend far enough 36"from the floor and extends 54"from rear wall from the rear wall at 51" 20 Riverside Restroom Interior Men's Toilet paper dispenser is mounted too close to the grab 609.3 Medium If built before 3/15/2012,do not need toadress bar in the access stall on the Men's side 21 Riverside Restroom Interior Men's There is no rear grab bar in the access stall of restroom 604.5 High Install a rear grab bar that is 36"long,and extends 12" from centerline of toilet to side wall and 24"to open side, and is 33-36"from the floor in both access stalls 22 Riverside Restroom Interior Women's There is no rear grab bar in the access stall of restroom 604.5 High Install a rear grab bar that is 36"long,and extends 12" from centerline of toilet to side wall and 24"to open side, and is 33-36"from the Floor in both access stalls 23 Riverside Restroom Interior Men's Flush controls require more than the maximum force limit 605.4 High Adjust or replace flush control where maximum force to operate,measuring at 13Lbs in the Men's needed to operate is 5Lbs 24 Riverside Restroom Interior Women's Flush controls require more than the maximum force limit 605.4 High Adjust or replace flush control where maximum force to operate,measuring at 14Lbs in the Women's needed to operate Is 5Lbs 25 Riverside Restroom Interior Men's Flush controls mounted in wall behind toilet in the middle 604.6 High Re-locate flush controls to the open side of the toilet or replace with autoflush 26 Riverside Restroom Interior Women's Flush controls mounted in wall behind toilet in the middle 604.6 High Re-locate flush controls to the open side of the toilet or replace with autoflush 27 Riverside Restroom Interior Men's Toilet paper dispenser is mounted to close to the toilet 604.7 N/A If built before 3/15/2012,do not need toadress 28 Riverside Restroom Interior Women's Toilet paper dispenser is mounted to close to the toilet 604.7 N/A If built before 3/15/2012,do not need toadress 29 Riverside Restroom Interior Men's There is no accessible approach to the access stalls 604.8.1.2 High Reconfigure partition so that there is 18"of maneuvering space on the latch side and 60"of clear depth 30 Riverside Restroom Interior Women's There is no accessible approach to the access stalls 604.8.1.2 High Reconfigure partition so that there is 18"of maneuvering spaco on the latch side and 60"of clear depth 31 Riverside Restroom Interior Men's The access stall doors are not self-dosing 604.8.1.2 Medium Install self-closing hinges on the access stall doors 32 Riverside Restroom Interior Women's The access stall doors are not self-dosing 604.8.1.2 Medium Install self-closing hinges on the access stall doors 33 Riverside Restroom Interior Women's The women's access stall door does not have any handles 604.8.1.2 High Mount ADA-compliant handles on both sides of the access while the access stall door stall doors 34 Riverside Restroom Interior Men's The Men's access stall door has a handle on the inside only 604.8.1.2 High Mount ADA-compliant handles on both sides of the access stall doors 35 2020 Town of Estes Park ADA Audit Summary Report Severity analysis rating: 1.1figh-.condition which significantly impedes or prohibits the ability of the public to access TOEP programs and services. 2.Moderate-A condition...affects the ability of the public to access TOEP programs and services in a minor way or a condition which only affects TOEP staff. Created by:Kasey McMorton 3.1.ow-A condition which has no effect on Me ability of Me public to access TOEP programs and services or a condition in which Mere is only a minor deviation from Me requirements of Me code. Building Area/Location Zone/Section Non-compliant Element Compliance Section Severity Corrective Measure Photo Estimated Cost Timeframe _ Performance Park Amphitheatre and Restroom Parking Lot Access Spaces No Van Accessible Space 208.2.4 High Create a van access space in parking lot Van access space - 1,.'. • - - , should be a total of 16"wide with access space and aisle 1 . ...._, .... Performance Park Amphitheatre and Restroom Parking Lot Access Spaces Access Space in East Lot is Missing Access Aisle 502.3 Medium liieedsutcoe csrpeaecteesweid,ecth(clels'sie6"aicsurrently)to 8'and reconfigure,n . ......„i 1 ir.---- - — 2 Performance Park Amphitheatre and Restroom Parking Lot Access Space Pair by Restrooms Slope of access space by restrooms was measured at 4.2% 502.4 High Regrade parking area with slope of<2%in all directions rialprrl-•"if,..._, .... exceeding the 2%limit 3 .—:.• Performance Park Amphitheatre and Restroom Parking Lot Single Access Space on East side of Slope of access space near south east corner of main lot 502.4 Medium Regrade parking area with slope of<2%in all directions • Parking Lot was measured at 3%exceeding the 2%limit , - 4 Performance Park Amphitheatre and Restroom Parking Lot Access Spaces Access aisles DO NOT adjoin an accessible route 502.3 High Create an accessible route or relocate access spaces so 1(.1 Pr • access space aisles adjoin an accessible route ' 5 . ____ -- ,,, ,,. , • Performance Park Amphitheatre and Restroom Accessible Route Accessible Route-Flagstone Area There are tree grates aong the accessible route that have 302.3 High Replace tree grate with one that has openings less than%," 'i'.. i ‘ __ • , ,a opening width greater than measured close to 1", and may be parallel to travel depending on direction of travel 6 inr Performance Park Amphitheatre and Restroom Accessible Route Accessible Route-Flagstone Area Cross slope of stone walkway was measured at 1%near 403.3 Medium Stone walkway should be regraded so that the max cross ,'—' ---------__ (.11.'— '','.' 'i•.°'•°.- the top of the incline to 4%at the bottom of the incline. slope is 2%and the slope of the run does not exceed the - 400. - i•iiiMill Limit for cross slope is 2% 5%it is at now,which is the running slope limit 4-- 7 . - Performance Park Amphitheatre and Restroom Curb Ramps Main parking lot one next to Curb ramp by restrooms is too steep,running slope 406.1;405.2 High Regrade curb ramp to below the 8.3%limit . restrooms measured at 10.8% 8 . , Performance Park Amphitheatre and Restroom Curb Ramps Main parking lot one next to Landing area for curb ramp by restrooms is not level 406.4 High Regrade landing area so that there is 36"of level landing restrooms area(<2%slope In all directions) _ — 9 Performance Park Amphitheatre and Restroom Curb Ramps Main parking lot one next to Curb ramp flares by restrooms are too steep 406.3 Medium Regrade curb ramp flares to a slope of<8% restrooms Performance Park Amphitheatre and Restroom Curb Ramps Ramp by East Lot Landing area for curb ramp in east lot is not level 406.4 High Regrade landing area so that there is 36"of level landing T area(<2%slope In all directions). p t _ _ al�° 11 — asmi a.....:,_____ Performance Park Amphitheatre and Restroom Curb Ramps Ramp by East Lot Curb ramp flares in east lot are too steep 406.3 Medium Regrade curb ramp flares to a slope of<8%. .. 12 Performance Park Amphitheatre Accessible Route Amphitheatre Stage Drainage grates on stage run parallel with travel and have 302.3 High Replace grates with ones that have an opening of<33"and - --•--• 3'� „.2, gaps that are 33"to>1" run don't run parallel with travel 13 , "y'�Yk Performance Park Amphitheatre Doors Dressing Rooms Doors close too quickly from a 90°to 12°position 404.2.8 Medium Adjust door closers so that doors close from a 90°to 12° position In atleast 5 seconds 14 Performance Park Restroom signage Men's Restroom sign missing raised letters and Braille 703.2;703.3 High Replace restroom signs with ADA compliant ones 15 111V . MEN Performance Park Restroom signage Women's Restroom sign missing raised letters and Braille 703.2;703.4 High Replace restroom signs with ADA compliant ones • 16 t WOMEN Performance Park Restroom Signage Men's Restroom signs mounted in wrong position 703.4.1 Medium Mount restroom signs with highest lettering baseline at 60"and lowest letter at 48" 17 Performance Park Restroom Signage Women's Restroom signs mounted in wrong position 703.4.2 Medium Mount restroom signs with highest lettering baseline at 60"and lowest letter at 48" 18 Performance Park Restroom Entry Men's There is not enough depth for an approach on the pull side 404.2.4 High Add an automatic door opener of the door 19 Performance Park Restroom Entry Women's There is not enough depth for an approach on the pull side 404.2.5 High Add an automatic door opener of the door 20 Performance Park Restroom Entry Door Men's Maximum force limit exceeded to open doors 404.2.9 High Add an automatic door opener 21 Performance Park Restroom Entry Door Women's Maximum force limit exceeded to open doors 404.2.10 High Add an automatic door opener 22 Performance Park Restroom Entry Door Men's Doors close too quickly from a 90°to 12°position 404.2.8 High Adjust door closer or add an automatic door opener 23 Performance Park Restroom Entry Door Women's Doors close too quickly from a 90°to 12°position 404.2.9 High Adjust door closer or add an automatic door opener 24 Performance Park Restroom Access Stall Men's Coat hooks in access stalls are too high 603.4 Medium Move hook to height within compliance,15-48"from floor 25 Performance Park Restroom Access Stall Women's Coat hooks in access stalls are too high 604.4 Medium Move hook to height within compliance,15-48"from floor 26 Performance Park Restroom Lavatory Men's Faucets require too much force to operate 606.4 High Adjust faucet if possible,otherwise replace with automatic type that is compliant 27 Performance Park Restroom Lavatory Women's Faucets require too much force to operate 607.4 High Adjust faucet if possible,otherwise replace with automatic type that Is compliant 28 Performance Park Restroom Access Stall Men's Grab bar in access stall on Men's side is mounted too high 609.4 High Relocate grab bar so that it is in compliance,top of gripping surface between 33-36" 29 Performance Park Restroom Access Stall Men's Flush control in access stall exceeds maximum force limit 605.4 Medium Adjust or change flush control to automatic 30 Performance Park Restroom Access Stall Women's Flush control in access stall exceeds maximum force limit 605.4 Medium Adjust or change flush control to automatic 31 Performance Park Restroom Access Stall Men's and Women's Toilet paper dispensers are mounted in the wrong position 604.7 N/A If built before 3/15/2012 no need to address 32 Performance Park Restroom Access Stall Women's Wall mounted items in Women's access stall reducethe 604.8.1.2 Medium Relocate obstructions from back wall to side wall. clear depth for a front approach to under the minimum limit 33 Performance Park Restroom Access Stall Men's Access stall door is not self-closing 604.8.1.2 Medium Add self-closing hinges to access stall doors 34 Performance Park Restroom Access Stall Women's Access stall door is not self-closing 604.8.1.3 Medium Add self-closing hinges to access stall doors 35 Performance Park Restroom Access Stall Men's Non-ADA pull handles are on inside/pull side of access stall 604.8.1.2 High ADA-compliant handles should be installed on both sides doors only of the access stall door at the proper height 36 Performance Park Restroom Access Stall Women's Non-ADA pull handles are on inside/pull side of access stall 604.8.1.2 High ADA-compliant handles should be installed on both odes doors only of the access stall door at the proper height 37 2020 Town of Estes Park ADA Audit Summary Report Severity analysis rating: LH 411- condition MI.significantly impedes or prohibits the ability of.public to access TOEP programs and services. 2.Moderate—A condition lob.affec.Me ability of the public to access TOEP programs and services in a minor way or a cond....only affects TOEP staff. Created by:Kasey McMorton IL.—A condition.iofl has no effect on Me ability of Me public to access TOEP programs and services or a condition in...Mere is only a minor deviation horn Me requirements of Me code. Building Area/Location Zone/Section Non-compliant Element Compliance Section Seventy Corrective Measure Photo Estimated Cost Timeframe Hydroplant Area Museum Office By Restrooms There is an inadequate amount of floor space beyond the 703.4.2 High Move signage to area that n not in door swing,or change LI arc of the door swing for signage. door swing to swing Into restroom and put sign on outside 2 u of door 1 Hydroplant Area Museum Office By Restrooms There is not enough maneuvering clearance fort front 404.2.4 High Either relocate heater or add an automatic opener 111, approach due to the heater located 7%"from the latch pull side of the door 2 T 2 Hydroplant Area Museum Office Accessible Restroom Doors close too quickly from a 90°to 12°position 404.2.8 High Adjust hinge closers or add an adjustable doter so that door closes In no less than 5 seconds 3 Hydroplant Area Museum Office Accessible Restroom There is an inadequate amount of clear floor space for a 606.2 Medium Either alter lavatory or relocate baseboard heater forward approach to the lavatory due to the baseboard heater installed on the outside wall that limits the depth to 4635" 4 Hydroplant Area Museum Office Accessible Restroom There is an inadequate amount of clearance around that 604.3.1 High Lavatory should be relocated so that there is at least 60" water closet due to the lavatory being located 3914"from from the side wall the wall with the water closet in between 5 Hydroplant Area Museum Office Accessible Restroom The grab bar on the side wall extends 47%"from rear wall 604.5.1 Medium Relocate grab bar where it is no more than 12"from rear instead of 54" wall and extends at least 54 6 Hydroplant Area Museum Office Accessible Restroom The top of the gripping surface for the side wall grab bar is 609.4 Medium Relocate grab bar with the top gripping surface no greater too high at 36 Y4" than 36"from the floor 7 Hydroplant Area Museum Office Accessible Restroom The grab bar on the rear wall extends only 20"from the 604.5.2 Medium Relocate grab bar where it extends 24"from the centerline centerline to the open side of the water closet of the water closet to the open side 8 Hydroplant Area Museum Office Accessible Restroom The top of the gripping surface for the rear wall grab bar is 609.4 Medium Relocate grab bar with the top gripping surface no greater too high at 36 3/8" than 36"from the Floor 9 2020 Town of Estes Park ADA Audit Summary Report severity analysis rating: Leigh-A condition which significantly impedes or prohibits the ability of the public to access TOEP programs and services. efinoderate-A condition which affects the ability of the public to access TOEP programs and services in a minor way or a condilion which only affects TOEP staff. Created by:Kasey McMorton Slow-A condition which has no effect on Me ability of Me public to access TOEP programs and services or a condition in which Mere is only a minor deviation from the requirements of Me code. Building Area/Location Zone/Section Non-compliant Element Compliance Section-Severity Corrective Measure Non-Compliance Photo Estimated Cost Timeframe Town Hall Bond Park Parking Lot Access Parking Space-North The cross slope of the access space is 2.2'and the front to 502.4 Medium Regrade parking surface so that the slope is no greater - - back slope is 1.7°which are both greater than the than 1.2°In any direction. • maxiumum slope of 1.2°in any direction. • • 1 -COM . _ _ . _ Town Hall Bond Park Parking Lot Access Parking Space-Access Aisle The cross slope of the access space is 2.1'and the front to 503.4 High Regrade parking surface so that the slope is no greater back slope is 2.4°which are both greater than the than 1.2°M any direction. maxiumum slope of 1.2°in any direction. 2 .1!— Town Hall Bond Park Parking Lot Access Parking Space-South The cross slope of the access space is 1.7'which is greater 504.4 Low Regrade parking surface so that the slope is no greater than the maxiumum slope of 1.2"In any direction. than 1.2°In any direction. 3 Town Hall Bond Park Parking Lot Access Parking Space-South There is no"Van Accessible"sign for this van accessible 502.6 Low Install a"Vasn Accessible"sign on the access space sign parking space.The space Is van accessible due to the post where the sign Is a minimum of 60"above the access aisle having an 8.13"width and the parking space ground. having a similar width. 4 Town Hall Accessible Route Public Restroom Entry The first section of sidewalk to the public restroom 403.3 Low Regrade walking surface so that the cross slope is no entrance had a cross slope of 1.5"while the maxium cross greater than 1.2°. slope is 1.2°. 5 Town Hall Accessible Route Board Room Lobby Ramp The board room lobby ramp is aproximated to be 15"in 405.8 Medium Add handrails to both side of the ramp where the gripping 'Alt 7,7k`` rise and there are no handrails. surface is 34-38"in height,the gripping surface is continuous,the iaeter of the hanrad is adequate, extend 12"beyond diameter the ends of d the ramp,and have atleast 6 36"between the handrails. Town Hall Accessible Entries Board Room Lobby Interior Doors The non-ADA door closes from a 90°position to a 12°in 3.5 404.2.8 Low Adjust closer so that door closes from a 90°position to a seconds.The left door Is operated by a ADA-compliant 12°position In no less than S seconds. push button. 7 Town Hall Accessible Entnes Public Restroom Entry Doors The non-ADA door closes from a 90°position to a 12°in 2.5 404.2.9 Low Adjust closer so that door closes from a 90°position to a seconds.The left door is operated by a ADA-compliant 12°position in no less than 5 seconds. push button. 8 Town Hall Accessible Entries Public Restroom Entry There is a commercial mat at the public restroom entry 302.2 Low Secure edges of rug to Floor. that does not have the edges secured to the ground.The edges are weighted with rubber to make for an easier transition onto them and is 1/4"thick. 9 Town Hall Rear Parking Lot Access Spaces The van accessible space in the rear is 10'10"wide with an 502.2 Low Restnpe parking space so that the space is 11.wide with a s access aisle that Is 6'4"wide for a total width of 17'2".This 5'wide access aisle or 8'wide parking space with an 8' is more than the required 16'total width but does not fit wide access aisle. "1 with the configuration options allowed. 10 Town Hall Rear Parking Lot Access Spaces-West Access Aisle The aisle is not striped to discourage people from parking 502.3.3 Medium Stripe the access space to discourage people from parking In It. In It. • ° 11 Town Hall Rear Parking Lot Access Spaces-Westernmost The cross slope of the parking space is 1.4-2.1°and the 502.4 High Regrade parking surface so that the slope is no greater 4 slope front to back Is 1.9-2.6°which are greater than the than 1.2°In any direction. 1.2°maxium in any direction. _ 12 Town Hall Rear Parking Lot Access Spaces-Wert Access Aisle The cross slope of the parking space is 0.8-1.7°and the 503.4 High Regrade parking surface so that the slope is no greater slope front to back ist.3-2.7°which are greater than the than 1.2°In any direction. - 1.2°maxium in any direction. 13 Town Hall Rear Parking Lot Access Spaces-Van Accessible Space The cross slope of the parking space is 0.7-1.5°and the 504.4 Medium Regrade parking surface so that the slope is no greater slope front to back Is 0.5-2.7°which are greater than the than 1.2°In any direction. 1.2°maxium in any direction. 14 Town Hall Rear Parking Lot Access Spaces-Middle East Space The cross slope of the parking space is 0.2-2.6°and the 505.4 High Regrade parking surface so that the slope is no greater slope front to back Is 0.6-5.7°which are greater than the than 1.2°In any direction. 1.2°maxium in any direction. 15 Town Hall Rear Parking Lot Access Spaces-East Access Aisle The cross slope of the parking space is 0.7-1.7'and the 506.4 High Regrade parking surface so that the slope is no greater .i°"...6.. - slope front to back ls0.8-3.8°which are greater than the than 1.2°In any direction. 1.2°maxium in any direction. 16 Town Hall Rear Parking Lot Access Spaces-Easternmost The slope front to back is 0.7-4.1°which is greater than 507.4 High Regrade parking surface so that the slope is no greater the 1.2°maxium in any direction. than 1.2°In any direction. 17 ~'! ags"� Town Hall Rear Parking Lot Access Spaces-East Access Aisle Does not connect to the accessible route and requires 502.3 High Add a curb cut to the front of the accessible aisle so that rt<.-"' 'gam going over the curb or going through the parking lot to get Is connected to the accessible route. lip to the accessible route. - 18 Town Hall Rear Parking Lot Curb Ramps-Corner of Town Hall by The running slope of the curb ramp is 4.6-5.0°which is 406.1;405.2 Medium Regrade curb ramp so that the maxium running slope is PD greater than the maxlum of 4.8° 4 8° 19 Town Hall South side of Town Hall-Bus Pullout Curb Ramps-West end of bus The very bottom of the curb ramp has a running slope of 406.1;405.3 Low Regrade curb ramp so that the maxium running slope is pullout 5.4-6.5°while the rest is 3.1-4.6°and the maximum 4.8° running slope is 4.8°. L 20 Town Hall PD Parking Lot Curb ramp-by PD parking lot entry The cross slope of the curb ramp is 1.3-1.9°while the 406.1;405.4 Medium Regrade curb ramp so that the maxium slope in any rw maximum is 1.2°. direction is 1.2° 21 Town Hall Rear Parking Lot Curb ramp-by Access Spaces The cross slope of the curb ramp is 1.4-1.7°while the 406.1;405.5 Medium Regrade curb ramp so that the maxium slope in any maximum is 1.2°. direction is 1.2° 22 Town Hall Bond Park Parking Lot/MacGregor Curb ramp-for crosswalk that The landing area at the top of the curb ramp has a running 406.4 High Curb ramp will need to be reconfigured so that the Ave crosses Macgregor by PD parking lot slope of 3.9-4.5°and the cross slope is 1.0-1.6°.The maximum slope of the landing area Is 1.2°. entrance maximum slope in any direction is 1.2°. 23 Town Hall Bond Park Parking Lot/MacGregor Curb ramp-for crosswalk that The left curb ramp flair slope is 7.8°and is over the 406.4 High Curb ramp will need to be reconfigured so that the Ave crosses Macgregor by PD parking lot maximum of 5.67°. maximum slope of the curb ramp fairs are 5.67°. entrance 24 Town Hall Rear Parking Lot Curb Ramps-Corner of Town Hall by There is no landing for the curb ramp. 406.4 High Reconfigure curb ramp so that there is a landing with slope PD no greater than 1.2°In any directin and is atleast 36'long and as wide as the ramp. 25 Town Hall Rear Parking Lot Curb ramp-by Access Spaces The landing area of the curb ramp has a cross slope of 0.9-406.4 Medium Regrade landing area so that the slope is any direction in P 2.3°which is greater than the maximum of 1.2°. no greater than 1.2°. 26 Town Hall PD Parking Lot Curb ramp-by PD parking lot entry The right curb ramp flare has a slope of 7.5°which is over 406.3 Low Regrade curb ramp flare where the slope is no greater the maximum of 5.67°. than 5.67°. 27 Town Hall Rear Parking Lot Curb Ramps-Corner of Town Hall by The left curb ramp flare has a slope of 5.9°which is over 406.3 High Regrade curb ramp flare where the slope is no greaterI!! PD the maximum of 5.67°.The Issue is of greater concern due than 5.67°. to the curb ramp no having a level landing area. 28 Town Hall Rear Parking Lot Curb ramp-by Access Spaces The curb ramp right flare has a slope of 7.7°which is over 406.3 Medium Regrzde curb ramp flare where the slope is no greater the maximum of 5.67°. than 5.67°. 29 405.7.2405.7.3 Lowof 66" 30 mio Town Hall Town Hall South Sidewalk Ramp-south sidewalk to under South side ramp is 891/2"wide and narrows to 41"at the 405.7.2;405.7.4 Medium Reconfigure the ramp and/or landing areas so that they south deck bottom due to flares.The top narrows to 591/2"due to are atleast 60"long and as wide as the ramp. P �,4La rn the column.Niether are as wide as the ramp r y�, 31 — � Town Hall Town Hall South Sidewalk Ramp-south sidewalk to under The rise of the south side ramp was approximated at 12" 405.8 Medium Add handrails to both side of the ramp where the gripping y:), I` _ ' ;l r, south deck and there is no handrail. surface Is 34-38"In height,the gripping surface is - �'— continuous,the diameter of the handrail is adequate, extend 12"beyond the ends of the ramp,and have atleast - - 32 36"between the handrails. Town Hall Accessible Entres Signage There is no sgnage directing people to the ADA accessible 216.6 Medium Add signs to the west admin lobby entrance directing entries. people to the other ADA accessible entries.Add signs to accessible entries as well in compliance with 216.6. 33 Town Hall Accessible Entries Admin Lobby East Door The front approach to the pull side of the door is only 14" 404.2.4 Medium Move shoes brush so there is 18"of front approach width wide on the exterior due to the shoe brush bolted to beyond the arc of the door.sidewalk.The door does have an ADA push button to operate the door. _ ' 34 Town Hall Accessible Entries PW Entry Door The exterior door closes in 3.5 seconds and the interior 404.2.8 High Adlust closer so that door closes from a 90°position to a door closes In 4.5 seconds which are both under the 12°position In no less than 5 seconds. minimum of 5 seconds. 35 Town Hall Accessible Entries Admin lobby West,Admin lobby Entrances have rugs that are not secured to the goround. 302.2 Low Rugs have rubber edge to hold them down but are East,and PW Entry required to be securly attached to the Floor 36 Town Hall Accessible Route Twin Owls Hallway The FE cabinet protrudes 5"into hallway with a bottom 307.2 Medium Replace cabinet with one the protrudes no more than 4" leading edge at 34"above the ground. from the wall. 37 Town Hall Accessible Route PD Lobby The top of the PD phone in the PD lobby protrudes 5"from 307.2 Low Phone is located in a wide hallway and is not as much of an the wall and Is 38"from the ground. Issue as It would be in a different hallway.The phone should be replaced with one that protrudes no more than 4"from the wall or the phone lowered so that the leading 38 edge is 27"maximum from the ground. Town Hall Ramps Board Room The ramp in the board room does not have enough landing 405.7.2 Medium When walls are up for Surdance and Twin Owls meeting space at the top,46",and is short of the required 60". rooms, ms,the ramp is not ADA-compliant.When the walls are put away,there is 60-0 of space and ramp is compliant. 39 Town Hall Ramps Board room lobby to public The bottom landing area for the ramp is not ADA 405.7.3' High Due to the bumpout being an exterior wall, restrooms ramp/hallway compliant due to the wall bumpout causing the landing reconfiguration is not possible or would be very expensive. area to be411/2"due to the 43/4"wall bumpout. Best solution is to add a push botton to allow the door to S. be opened at the top of the ramp and to stay open for 40 minute minimum. --- — Town Hall Ramps Public Restroom Area The bottom landing area for the ramp is not ADA 405.7.3 High Reconfiguration is not possible or would be very compliant The landing space Is 46"In length and Is less expensive.Best solution is to add a push botton to allow , l-_I than the 60"minimum. the door to be opened at the top of the ramp and to stay — open for 1 minute minimum.This would Increase the 1 41 landing space of the ramp when the door is open. Town Hall Ramps Board Room The ramp in the board room as a rise greated than 6"and 405.8 High The ramp is the only accessible route to the lower portion there Is NO handrail. of the board room and the location of the ADA seating 81111116, spaces.Due to this,the ramp is NOT exepmt from the ' handrail requirement and need a handrail Installed. 42 j • Town Hall Ramps Board room lobby to public The handrail extends 4"beyond the ramp at the top which 405.8 Medium The handrail should be reconfigured so that it extends 12" restrooms ramp/hallway Is less than the 12"minimum. beyond the end of the ramp and return to the wall. 43 Town Hall Ramps Public Restroom Area The north handrail is 33/4"short of the top of the ramp 405.8 High Reconfigure handrails so that extend 12"beyond the and extend 6"beyond the bottom of the ramp.The south bottom of the ramp.The top of the ramp is tricky with the , ' , handrail is 31/4"short of the top of the ramp and extend public restroom entrances and door swings addecent to the L -- 4.5"beyond the bottom of the ramp.All of these top.May need to bring the handrail as close to the ramp 1 4 44 measurements are less than the 12"minimum end as possible. 1 requirement. Town Hall Signs Utility Pay Box Characters are not raised and there is no braille. 703.2;703.3 Low Replace with ADA compliant sign. 45 Town Hall Signs Finance Hall Door Characters are not raised and there is no braille. 703.2;703.4 Low Replace with ADA compliant sign. 46 Town Hall Signs Board Room and room name signs Characters are not raised,there is no braille,sign is 703.3;703.4;703.4.2 High Add signs on walls by doors that are ADA compliant with over entry doors mounted over the door with no other signage. raised charecters and braille. 47 Town Hall Signs Restroom Ramp Characters are not raised,there is no braille,sign is 703.3;703.4;703.4.3 High Add signs on wall by door that are ADA compliant with mounted over the door with no other signage. raised charecters and braille. 48 Town Hall Signs Exit Signs-throughout facility Characters are not raised,there is no braille,sign is 703.3;703.4;703.4.4 High Add ADA compliant exit signs at all exits. mounted from ceiling except for the board room lobby, mounted on wall. 49 Town Hall Signs PD Lobby PD sign is mounted with charecters 58-76 3/4"in height 703.4.1 Medium Mount sign so that the lowest character baseline is 48"and which Is outside of the 48-60"range. highest Is 60". 50 Town Hall Interior Doors Twin Owls Door There is only 133/4"of manuevenng space beyond latch 404.2.4 High Add automatic opening push button to door. which Is less than the 18"required. ILL I 51 1 Town Hall Interior Doors Board room lobby to public There is only 151/2"of manuevering space beyond latch 404.2.4 High Add automatic opening push button to door. restrooms ramp/hallway Door which Is less than the 18"required. • 52 \Town Hall Interior Doors Pubblic RR Door to Utility Billing There is only 171/2"of manuevering space beyond latch 404.2.4 High Add automatic opening push button to door. and 46"deep which is less than the 18"x 60"required. V 53 1I 1 Town Hall Interior Doors Board Room Door Door requires 6 pounds of force to operate which is more 404.2.9 Low Adjust closer or add an automatic opener with push than the 5 pound maximum. button. 54 Town Hall Interior Doors Twin Owls Door Door requires 6 pounds of force to operate which is more 404.2.9 Low Adjust closer or add an automatic opener with push than the 5 pound maximum. button. 55 Town Hall Interior Doors Public RR Door from board room Door requires 10 pounds of force to operate which is more 404.2.9 High Adjust closer or add an automatic opener with push lobby than the 5 pound maximum. button. 56 Town Hall Interior Doors Public RR door to utility billing Door requires 10 pounds of force to operate which is more 404.2.9 High Adjust closer or add an automatic opener with push than the 5 pound maximum. button. 57 Town Hall Interior Doors Finance hallway secured door Door requires 7 pounds of force to operate which is more 404.2.9 Low Adjust closer or add an automatic opener with push than the 5 pound maximum. button. 58 Town Hall Interior Doors Board Room Door The door closes too quickly from a 90°to 12°position, 404.2.8.1 High Adjust closer or add an automatic opener with push measured at 3 seconds which is under the 5 second limit button. 59 Town Hall Interior Doors 5undance Door The door closes too quickly from a 90°to 12°position, 404.2.8.1 Medium Adjust closer or add an automatic opener with push measured at 4.5 seconds which Is under the 5 second limit button. 60 Town Hall Interior Doors Twin Owls Door The door closes too quickly from a 90°to 12°position, 404.2.8.2 Medium Adjust closer or add an automatic opener with push measured at 4.5 seconds which Is under the 5 second limit button. 61 Town Hall Interior Doors Public RR Door from board room The door closes too quickly from a 90°to 12°position, 404.2.8.3 Medium Adjust closer or add an automatic opener with push lobby measured at 4.25 seconds which is under the 5 second button. limit 62 Town Hall Interior Doors Public RR door to utility billing The door closes too quickly from a 90°to 12°position, 404.2.8.4 High Adjust 0100cr or add an automatic opener with push measured at 4 seconds which Is under the 5 second limit button. 63 Town Hall Controls T-stat in board room The t-stat is located at 61"from the ground which is over 309.3;30B Medium Change the height of the control to a maximum height of the 48"maximum. 46". 64 Town Hall Controls T-stat in board room lobby The t-stat is located at 61"from the ground which is over 309.3;308 Medium Change the height of the control to a maximum height of the 48"maximum. 48". 65 Town Hall Controls T-statin Sundance The t-stat is located at 61"from the ground which is over 309.3;308 Medium Change the height of the control to a maximum height of the 48"maximum. 48". 66 Town Hall Controls T-stat in Twin Owls The t-stat is located at 61"from the ground which is over 309.3;308 Medium Change the height of the control to a maximum height of the 48"maximum. 48". 67 Town Hall Controls T-stat in board room lobby T-stat is located over counter and does not have the 305.3 High Move t-stat so that there is adequate clear floor space. _ required 48"x 30"clear space. 68 _ ter 7 Town Hall Controls Board Room lobby,Sundance,and The t-stats have locked covers on the which require 309.4 High Replace t-stat with one that can be programmed and Twin Owl T-stats grasping a key to unlock to operate t-slat. settings locked out. 69 Town Hall Board Room Assembly Seating Wheelchair spaces are located at the very front or back ofr 221.2.3 Medium Reconfigure to disperse wheelchair spaces the seating area and not dispersed. I, 70 Town Hall Board Room Assembly Seating Wheelchair spaces that are located at the very front are 802.1.3 High Reconfigure seating area to allow adequate space for not of adequate size.The spaces on the east side by the wheelchair seating. stairs are only 30"deep before blocking the stairs. 71 Town Hall Board Room lobby computer Accessible Seating The computer workstation is not accessible for a person in 305.3;306.2;306.3 High Replace computer table with an ADA compliant one. a wheelchair.The surface top is 26 1/4"when the required height is 28-34".The dear floor space is 6 1/8"D x 42"W and 11 5/8"D x 27"which is less than the required 17 72 25".The knee space is 25 1/8"in height which is less than the 27"minimum. Town Hall Board room lobby counter Accessible seating The counter in the board room lobby is not accessible for a 306.2 Medium Reconfigure counter so the clear floor space extends 17- -I person In a wheel chair.The clear floor space is only 6 3/4. 25". 11 3/4"D which is less than the 17-25"required. 73 dliki •--- Town Hall Board Room Lobby Bistro Tables Accessible Seating The bistro tables in the board romm lobby are not 305.3;306.2 High Replace bistro tables with ADA compliant ones. ill accessible for a person in a wheelchair.The dear floor - space is 14 1/8"D and the table is 29 3/4"W.This is less than the require 17-25D dear floor space and the table Is 74 not as wide as the 30"W approach required. -VI' ... .—_ Town Hall PD Front Counter Accessible Seating The PD counter is not accessible for a person in a 306.2 High Reconfigure counter so that there is 17-25.clear floor ' . .-7 'I.— wheelchair.The clear floor space Is 5 3/4"D which is less space. - I iWCP - than the 17-25"required. 75 „i10126.' I \ *kr Town Hall Utility Billing Accessible Seating Left window is not accessible to a person in a wheelchair. 306.2 High Reconfigure counter so that there is 17-25 clear floor I The clear floor space Is 1 1/2"D which is less than the 17- space. 25"required. iS I_ ail i76 Town Hall Utility Billing Accessible Seating Middle window is not accessible to a person in a 306.2 High Reconfigure counter so that there is 17-25 clear floor Pr F INFI7R8 wheelchair.The clear floor space Is 1 1/2"D which Is less space. than the 17-25"required. 77 i:.......,0 I! Town Hall Utility Billing Accessible Seating Right window is not accessible to a person in a wheelchair.306.2;306.3 High Reconfigure counter so that there is 17-25 clear floor , ,8:, .ti r • The clear floor space Is B 1/2"D which is less than the 17- space and knee space of 27"minimum. 25"required.The knee space is 26 1/2"which is less than the 27"minimum. 78 Town Hall Board Room Accessible Seating The podium in the board room is not accessible to a 306.2 High Adjust podium so there is clear floor space of 17-25". 11 10--,1 person In a wheel chair.The clear floor space is 9"due to the floor plugs and cords underneath the podium and is less than the 17-25"required. 79 It ..t',.:7.ii..74.. . Town Hall PD Window Service Counter The PD counter is too tall in height at 41 1/2"where the 904.4.1 High Change front counter so that the maxium height is 36"or max is 36". there is a section of the counter that is 36"max In height .. I 111.!,o. and atleast 36"long. 80 Town Hall PD Window Service Counter The PD counter extend level across the entire surface, 904.4 Low May not need any changes? however,there is a fixed glass panel 7 7/8"from the edge. f'- 81 \ \T Town Hall Utility Billing Right Window Service Counter The counter is between 2 walls that are 251/2"deep and 904.4.1 Medium Remove the right wall to allow for a parallel approach ---..W INALICE INEORA TIOR the distance between the two Is 49 1/2". while maintaining privacy from the middle window. r .: ■ ` T 1 82 op an aim Town Hall Utility billing right window Service Counter The right window at utility billing is only 11/2"deep and 306.2.2,306.2.3, High Reconfigure counter so there is 27"minimum between the IN6I[E IM1EDRA TIOR there Is only 26 1/2"In height between Floor and obttom 306.3.1 bottom of the counter and the floor and clear floor space "1 r of counter. that extends 17-25"under counter. • 1 T 1 83 BOAIM Town Hall PD Window Service Counter The PD counter has clear floor space of 5 3/4". 306.2.2,306.2.3 High Reconfigure the counter so that clear floor space extends 17-25"under counter with 27"minimum of height from floor to counter bottom. 84 Town Hall Public Restrooms Men's entry door Door handle is 8 1/2"from left wall and door is set back 404.2.4 High Add automatic opening push button to door. 10"from left wall. A 85 Town Hall Public Restrooms Men's entry door Door requires 15 lbs of force to open 404.2.9 High Add automatic opening push button to door. A 86 Town Hall Public Restrooms Women's entry door Door requires 16 lbs of force to open 404.2.9 High Add automatic opening push button to door. 87 Town Hall Public Restrooms Men's entry door Door closes from a 90°position to a 12°position in 3.0 404.2.8.1 High Adjust closer so that door closes from a 90°position toa seconds. 12°position in no less than 5 seconds.OR Add an automatic opening push button to door. 88 Town Hall Public Restrooms Women's entry door Door closes from a 90°position to a 12°position in 3.25 404.2.8.2 High Adjust closer so that door closes from a 90°position to a seconds. 12°position in no less than 5 seconds.OR Add an automatic opening push button to door. 89 Town Hall Public Restrooms Men's Bottom of mirror edge is 41 7/8". 603.3 Medium Adjust mirror so bottom edge is 40"maoiumum. 90 Town Hall Public Restrooms Women's Bottom of mirror edge is 41 1/2". 603.3 Medium Adjust mirror so bottom edge is 40"maoiumum. 91 Town Hall Public Restrooms Men's and Women's there are metal brackets between the sink basins that are 606.5 Medium add protection to brackets ' —.,_.1 a Lt. 1 -- -..-.......:....., I-.. ;A unprotected .. 92 Town Hall Public Restrooms Women's ADA Toilet centerline is 18 1/2"from wall. 604.2 Medium Adjust toilet/stall so that toilet centerline is 18"from wall. 93 Town Hall Public Restrooms Men's ADA toilet height measured at 19 1/2“. 604.4 High 95 Adjust toilet so height is between 17-19". Town Hall Public Restrooms Women's Flush control on Ada toilet is on closed side of toilet,auto 604.6 Low Reconfigure so fluch control is on open side flush 96 Town Hall Public Restrooms Men's Flush control on Ada toilet is en closed side of toilet,auto 605.6 Low Reconfigure so Ruch control is on open side flush 97 Town Hall Public Restrooms Women's The first TP dispenser roll is not within the proper range 604.7 Low Can't do much due to the dispenser being a doulbe roll. while the second roll is. When one roll Is In limit the other Is not. 98 Town Hall Public Restrooms Men's Neither TP dispenser rool is within the proper limit 604.7 High Adjust TP dispenser so that the second TP roll is within 7- 9'.of the front of the toilet. 99 Town Hall Public Restrooms Women's There are 180"of manuevering space but will be in 604.8.2.1 High Adjust stall configuration or add automatic door doorway of adjacent stall.There Is only 54 3/4"of depth. opener/closer. 100 Town Hall Public Restrooms Men's There is only 42 1/2"of depth to the urinal partition for 604.8.1.2 High Adjust stall configuration or add automatic door the ADA stall. opener/closer. 101 Town Hall Public Restrooms Women's Ada stall door does NOT self close and instead self-open to 604.8.1.2 Medium Adjust door so that it self-closes 80 degrees. 102 Town Hall Public Restrooms Men's ADA stall door is not self-closing. 604.8.1.3 Medium Adjust door so that it self-closes 103 Town Hall Public Restroom Lobby Water Fountain Left water fountain spout is 39"above Floor 602.4 Low The ADA water fountain is compliant. 104 Town Hall Board Lobby Vestibule Town Phone The town phone on the bistro table does not hasve the 704.2.1 Medium Reconfigure vestibule so there is clear Floor space 48 x 30" proper clear floor space due to all the clear floor space minimum. being in the circulation path. 105 Town Hall Board Lobby Vestibule PD Phone The Pd phone has operable parts measured at 53". 704.2.2 High Adjust telephone so that the maximum height of operable parts Is 48" 106 Town Hall Board Lobby Vestibule PD Phone The PD phone does not have a volume control. 704.3 Medium Add volume control to phone. 107 Town Hall PD Lobby PD Lobby Phone The PD lobby phone does not have a volume control. 704.3 Medium Add volume control to phone. 108 Town Hall Board Lobby Vestibule Town Phone The town phone volume control is missing the proper 703.7.2.3 Low Add proper pictogram. pictogram and only has a+and- 109 Town Hall Board Lobby Vestibule PD Phone The TPy is not identified with the international symbol. 703.7.2.2 Medium Add international symbol for TPy 110 Town Hall Board,PD,and Utility billing lobbies Signage There are no directional signage directing to the TTy in the 216.9.2 Medium Add directional signage. board lobby vestiuble. 111 Town Hall PD lobby phone and Town Phone Signage Neither phone has directional signs to the Try. 216.9.2 Medium Add directional signage to all public phones that don't have a Try. 112 Town Hall Parking Lot-Rear Accessible Spaces There are 195 total parking spaces in the rear parking lot of 208.2 Medium Add one additional access space to the rear parking lot. Town Hall.5 of them are accessibles spaces which Is one below the minimum. 123 Town Hall Parking Lot-Rear Accessible Spaces-Van The Van accessible space does not conform to the typical 502.2 low Restnpe parking space to conform with thetypical P van sssible space dimension of 11'with 5'aisle or 8' dimensions. with 8'aisle.The space was measured as 10'10"with a 6'4"aisle. 124 Town Hall Parking Lot-Rear Access Aisle The west access aisle is not striped to discourage drivers 502.3.3 low Add striping to the access aisle similar to the east access from parking in it.It is a contrasting color cement)with aisle the asphalt parking surface. 125 Town Hall Parking Lot-Rear Accessuble Spaces and Access Aisles All of the accessible spaces and access aisles along the 502.4 High Regrade parking surface so it is no steeper than 1:48 in all sidewalk on the rear of Town Hall do not comply with directions having no part steeper than 1:48.Most issues occur along - curb/gutter portion. 126 Town Hall Parking Lot-Rear Access Aisle The east access aisle does rot haves curb cut to adjoin the 402.2;502.3 High Add curb cut so accessible aisle adjoins the accessible p -' —accessible route. route.'This may create a cross slope Issue with the accessible issue a by th from the library to the rear of Town Hall. Similar issue by the corner of PO. 127 Town Hall Accessible Route Curb Cuts The curb cut on the NE corner of the PD wing is steeper 406.1,405.2 Low Regrade curb ramp so the slope is less than 1:12 or4.8°. than 1.12 or 4.8°.The slope of the curb ramp was measured at 4.6-5.0°. 128 Town Hall Accessible Route Curb Cuts The curb cut for he bus pullout on the south side of Town 406.1;405.2 Low Regrade curb ramp so the slope is less than 1:12 or4.8°. • Hall had a slope of 5.4-6.5°at the very bottom which Is over the 1:12 or 4.8°limit. 129 • Town Hall Accessible Route Curb Cuts The curb cut on the NW corner of Town hall(crossing the 406.1;405.3 Medium Regrade curb ramp so the slope is less than 1:48 or 1.2°. 1 PD parking entrance)has a cross slope of 1.9°which is over _ the 1:48or1.2°limit 130 Town Hall Accessible Route Curb Cuts The curb cut on the rear of Town Hall by the accessible 406.1;405.3 Medium Regrade curb ramp so the slope is less than 1:48 or 1.2°. � parking spaces has a cross slope of 1.7°which Is over the _ 1:48 or 1.2°limit. - - 131 ....1�'✓awe+�... Town Hall Accessible Route Curb Cuts The curb cut west of Town Hall(crosses MacGregor)does 406.4 High Regrade landing area so that the slope is any direction in not have a level landing area and was measure with a slope no greater than 1.48 or 1.2°in all directions. of 3.9-4.5°which is over the 1:48 or 1.2°limit. 132 Town Hall Accessible Route Curb Cuts The curb cut on the NE corner of the PD wing does not 406.4 High Redo curb cut and sidewalk so that there is a compliant have a landing area. curb cut/ramp with a compliant landing area. 133 Town Hall Accessible Route Curb Cuts The curb cut by the bus pullout on the south side of Town 406.4 High Regrade the landing area so that it is level and no steeper Hall has a level landing area that was measured with a than 1:48 or 1.2°In any direction. cross slope of 2.3.which is more than the 1:48 or 1.2° limit. 134 Town Hall Accessible Route Curb Cuts The curb cut west of town Hall(crosses MacGregor)has 406.3 Medium Regrade curb cut so ramp flares have a slope of no more the left ramp Flare with a slope of 7.8°which Is greater than 1:10 or 5.67°. than the 1:10 or 5.67°limit. 135 Town Hall Accessible Route Curb Cuts The curb cut on the NW corner of Town hall(crossing the 406.3 Medium Regrade curb cut so ramp flares have a slope of no more _ _ I,. PD parking entrance)has a right ramp flare with a slope of than 1:10 or 5.67°. 7.5°which is over the 1:10 or 5.67.limit. 136 Town Hall Accessible Route Curb Cuts The curb cut on the NE corner of the PD wing has a left 406.3 Low Regrade curb cut so ramp flares have a slope of no more �11 ramp flare with a slope of 5.9°which is slightly more than than 1:10 or 5.67°. MIER Illl the 1:10 or 5.67°limit 137 Town Hall Accessible Route Curb Cuts The curb cut on the rear of Town Hall by the accessible 406.3 Medium Regrade curb cut so ramp flares have a slope of no more parking spaces has a right ramp flare with a slope of 7.7° than 1:10 or5.67°. which is over the 1:10 or 5.67°limit 138 \` Town Hall Ramps Rear Town Hall Sidewalk(By PD and The faux wood column and stone half wall restrict the 405.7.2 Low Ramp landing width is supposed to be the same as the Rear Board Room Door) ramp landing to 62"from the ramp width of 66'. ramp width.Could add trim to ramp side along wall to make ramp and landing the same width. 139 Town Hall Ramps Ramp on SW corner of TH by The ramp landings are 41"and 591/2"while the ramp 405.7.2;405.7.3 High Ramp landing width is supposed to be the same as the sidewalk covering width is 891/2". ramp width.Could add sides to ramp and restrict ramp width to 41"matching the bottom landing width. .1111111 . 140 • Town Hall Ramps Ramp on SW corner of TH by The ramp has an approximated rise of 12"and there is no 405.8 Low The ramp rise is similar to the ground level rise on either sidewalk covering handrail. side so a handrail may not be necessary. 141 Town Hall Entrances Signage There is no directional signs for the ADA accessible entries.216.6 Low Add signage to entries with directions to ADA accessible Admin lobby west entry not as accessible as admin lobby entries.Or add door openers to non accessible entries east (Adman lobby west)to make all public entries accessible. Would also want to add door opener to both ramp doors 142 in public restroom area. Town Hall Entrances Admm Lobby East Door There is only 14"of clearance due to the brush mounted 404.2.4 Low Move brush to lao"beyond the arc of the door. on the ground. 143 Town Hall Entrances Public Works Door There is only 21/4"of clearance space for the interior door 404.2.4 High Add automatic door opener and/or revers door swing in the vestibule. direction. 144 Town Hall Entrances PW Door Both doors close faster than the recommended 5 seconds.404.2.8 Medium Adjust door closer so doors close after 5 seconds. 145 Town Hall Entrances Admin Lobby West The rugs edges are not secured,only weighted down,and 302.2 Medium Secure edges or replace with an in floor system. could cause a trip hazard. 146 Town Hall Entrances Admin Lobby East The rugs edges are not secured,only weighted down,and 303.2 Medium Secure edges or replace with an in Floor system. could cause a trip hazard. 147 Town Hall Entrances PW Door The rugs edges are not secured,only weighted down,and 304.2 Medium Secure edges or replace with an in Floor system. could cause a trip hazard. 148 Town Hall Accessible Route Protruding Object The PW door handle and lock mechanism protrude 93/4" 307.2 Low May look at way to lessen the protrusion of the door and Into the hallway/door entry from the wall.The door Is at 7 handle to limit the Issues. 1/2"to the handle only protrudes 2"from the door. 1 _ 149 Town Hall Signs Finance South Hall Door Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; 703.4.1 150 Town Hall Signs Staff Breakroom Employees Only sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.2 151 M Town Hall Signs Mayor Office Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; 703.4.3 152 Town Hall Signs Public Restroom Directional from Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign South hallway door to utility billing 703.3;703.4.2, lobby 703.4.4 153 I lk r• Town Hall Signs South Hallway directional by finance Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign meeting room 703.3;703.4.2; 703.4.5 5D 154 Town Hall Signs Admin lobby west information by Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign entry door on glass 703.3;703.4.2, 703.4.6 k 155 Town Hall Signs Admm lobby east information by Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign entry door on glass 703.3;703.4.2; 703.4.7 - a 156 Town Hall Signs Meeting Room 62(Finanace meeting Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign room,door to atlmin lobby) 703.3;703.4.2, 703.4.8 157 Town Hall Signs Public Works entry Door Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign.Move or adjust bike 703.3;703.4.2; rack so that sign floor clearance Is not blocked by bikes. 703.4.9 f 158 ti Town Hall Signs Building Directory in Admin Lobby Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign on column 703.3;703.4.2, 703.4.10 159 • 7 t, Town Hall Signs Admin entry door Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; �.. 703.4.11 , ( F 160 Town Hall Signs PIO Office Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign - `\ 703.3;703.4.2, 703.4.12 I 1 161 f Town Hall Signs ATA Office Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; 703.4.13 162 Town Hall Signs TA ice Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.14 4 163 Town Hall Signs Meeting Room 81 Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.15 164 Town Hall Signs Meeting Room OD-Emergency Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign Exlt/Rear Door 703.3;703.4.2; 703.4.16 165 Town Hall Signs Trustees Office Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.17 166 Town Hall Signs Room 140 Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.18 167 Town Hall Signs Administration Services Sign by Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign Clerk's Window 703.3;703.4.2; C 703.4.19 168 Town Hall Signs Job Posting Sign Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign ,111111!!. 703.3;703.4.2, 703.4.20 169 Town Hall Signs Engineering Entry Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; 703.4.21 170 Town Hall Signs "Employee Only"on sliding gates Sign is not compliant with ADA 216.2;703.5;703.2; Medium ? 'a I 'I 703.3;703.4.2, 703.4.22 171 Town Hall Signs Utilities Coordinator/Project Sign is not compliant with ADA 216.2;703.5;703.2; Low Replace with an ADA compliant sign Manager 703.3;703.4.2, "�� 703.4.23 172 Town Hall Signs Meeting Room 3 Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, 703.4.24 Ii7,1 I MIL 173 Town Hall Signs Director of Public Works Sign is not compliant with ADA 216.2;703.5;703.2; Low Replace with an ADA compliant sign 703.3;703.4.2; 703.4.25 , 174 Town Hall Signs Utilities Director Sign is not compliant with ADA 216.2;703.5;703.2; Low Replace with an ADA compliant sign 703.3;703.4.2, 703.4.26 175 Town Hall Signs Public Works Operations Manager Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, l'� 703.4.27 1ti$1, 11111 17600, �` I Town Hall Signs Facility Manager office Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2; 703.4.28 177 Town Hall Signs Public Works Engineering Manager Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign 703.3;703.4.2, ,4111 703.4.29 178 Town Hall Signs Public Works Emergency Exit Sign is not compliant with ADA 216.2;703.5;703.2; High Replace with an ADA compliant sign EAIi 703.3;703.4.2; 703.4.30 111 179 Town Hall Doorways Administration Entry The wood and glass doorway is not ADA compliant.The 404.2.3 High Replace doorway with an ADA compliant one. latch and push bar restrict the doorway to 30". 180 L. r ' EPI Town Hall Doorways Administration sliding gate The sliding gate next to the front desk in administration is 404.2.3 High Reconfigure or replace sliding gate so that there is 32"for 30"wide and not ADA compliant at 32". the doorway aJ 181 �� Town Hall Door Breakroom The placement of the trashcan in the breakroom restricts 404.2.4 Medium Move trashcan to different location so tha there is ADA the maneuvering clearance to 15 3/4". compliant manuevering space. 182 Town Hall Door Admm entry from the inside of There is only 06"to the half wall instead of the required 404.2.4 High Remove half wall so there is 18"of manuevenng clearance Admin 18". or add an automatic door opener 183 Town Hall Door Meeting room 3 door from inside There is only 71/2"to the trash can instead of the 404.2.4 Medium Reconfigure furniture so there is 18"of manuevenng meeting room 3 required 18" clearance. ., 184 Town Hall Threshold Room 140 The threshold for the doorway is 1"tall with the top 3/4" 404.2.5;303.2 Medium Reconfigure doorway and/or flooring so there is only 3/4" beveled.Max for a threshold is 3/4" threshold Instead of 1". 185 • Town Hall Door Hardware Meeting Room 0 The door knob is round and requires tight grasping to 404.2.7 Medium Replace door knob with an ADA compliant door handle. operate.Not ADA compliant. 186 Town Hall Door Hardware Meeting Room 3 The door knob is round and requires tight grasping to 404.2.8 Medium Replace door knob with an ADA compliant door handle. operate.Not ADA compliant. I'ELI 187 Town Hall Door Admin Entry Door Glass Requires DDlbs of force to open which is over the Sibs for 404.2.9 High Adjust door closer or replace door so there is no more ADA compliance, than 51bs of force required to open the doors. "1 , 188 ,- Town Hall Door Room 140 Requires 7Ibs of force to open which is over the Sibs for 404.2.10 Low Adjust door closer.Room is a personal office so door is ADA compliance, propped open during day. 189 • Town Hall Door Clerk's Door Requires Bibs of force to open which is over the 51bs for 404.2.11 Low Adjust door closer.Office is secured and public is escorted ADA compliance, In and out. 190 Town Hall Door Clerk's Door door closes from 90.to 12.in 2.6 seconds 404.2.8.1 Low Adjust door closer.Office is secured and public is escorted In and out. 191 Town Hall Door Meeting room 2 Door closes from 90°to 12.in 2.6 seconds 404.2.8.1 High Adjust door closer so doors closes after 5 seconds. 192 Town Hall Controls Admin Lobby West Vestibule The light switch is located at 53 1/4"above the floor which 309.3;308 Low Adjust light switch so operable parts are no higher than Is over the 48"limit. 48"fom the ground. 193 Town Hall Controls Admin lobby East Vestibule The light switch is located at 53"above the floor which is 309.3;308 Low Adjust light switch so operable parts are no higher than over the 48"limit. 48"fom the ground. 194 Town Hall Controls Finance Hallway by breakroom. The light switch is located at 53 1/2"above the floor which 309.3;308 Low Adjust light switch so operable parts are no higherthan Is over the 48"limit. 48"fom the ground. 195 Town Hall Controls Breakroom The light switch is located at 53"above the floor which is 309.3;308 Low Adjust light switch so operable parts are no higher than over the 48"limit.There Is also no clear floor space due to 48"fom the ground.Relocate trashcan where It does not the trashcan. block any controls. 196 Town Hall Controls Breakroom The T-stat is located at 51 1/2"above the floor which is 309.3;308 Low Adjust T-stat so operable parts are no higher than 48"fom over the 48"limit.There Is also no clear floor space due to the ground.Relocate trashcan where It does not block any the trashcan, controls. 197 Town Hall Controls Finance Hall by Admin lobby The"Intermatic"switch is located at 54"above the floor 309.3;308 Low Adjust"Intermatic"switch so operable parts are no higher which Is over the 48"limit, than 48"tom the ground. 198 Town Hall Controls Public Works Hallway The light switch is located at 53"above the floor which is 309.3;308 Low Adjust light switch so operable parts are no higher than over the 48"limit. 48"fom the ground. 199 Town Hall Controls Admin Office by Front Door The light switch is located at 593/4"above the floor which 309.3;308 Low Adjust light switch so operable parts are no higherthan Is over the 48"limit.There Is also only 13"wide for clear 48"fom the ground.Relocate light swltc to area where flor space and is et bac from door 51/4" there is adequate floor space. 200 Town Hall Controls Admin Conference Room The light switch is located at 54 1/4"above the floor which 309.3;308 Low Adjust light switch so operable parts are no higher than Is over the 48"limit. 48"fom the ground. 201 Town Hall Controls Admin Conference Room The light switch is located at 53"above the floor which is 309.3;308 Low Adjust light switch so operable parts are no higher than Kitchenette over the 48"limit.There is also a trashcan that limits the 48"fom the ground.Relocate trashcan. clear floor space. 202 Town Hall Controls Admin Conference Room Restroom The light and fan switches are located at 52 3/4"above the 309.3;308 Low Adjust light switch so operable parts are no higherthan ground.The toilet also blcoks all clear floor space. 48"fom the ground and there Is clear floor space. 203 Town Hall Controls Meeting Room 02 Both light switches in the room are located 431/4"which 305.3 Low Adjust items in room to allw for adequate clear floor is compliant with ADA.However there is not adequate space. clear floor space.The switch by the door from finance office is blocked by a trashcan.The light switch by the 204 adman lobby door is limited in clear floor space due to the conference table. Town Hall Controls Meeting Room 82 The A/C controller is mounted at 47 3/4-54"above the 309.3;308 Low Adjust A/C control so operable parts are below 48"from ground with the operable parts above 48". the ground Fik 205 Town Hall Controls Public Works The main light switches at the front of PW are located 52 309.3;308;305.3 Low Adjust light switch so operable parts are no higherthan 1/2"from the ground which is over the 48"limit.There is 48"fom the ground.Adjust chairs so there isadaquate A also no clear floor space due to the chairs. clear floor space. 206 Town Hall Controls Public Works The main office light switch is located 491/4"above the 309.3;308;305.3 Low Adjust light switch so operable parts are no higher than ground which is over the 48"limit. 48"fom the ground. 207 Town Hall Controls Meeting Room 03 The light switch is located 491/4"above the ground which 309.3;308;305.4 Low Adjust light switch so operable parts are no higherthan Is over the 48"limit.The clear floor space is also limited 48"fom the ground.when the meeting room door is open. 208 Town Hall Controls Breakroom The breakroom t-stat is only operable with tight grasping 309.4 Low Replace t-stat with an ADA compliant one. of a knob to adjust t-stat. 209 Town Hall Controls Finance Hall by Admin lobby "Intermabc"switch has very small buttons. 309.4 Low Replace switchwith an ADA compliant one. 210 Town Hall Service Counter Admin The front counter is located at a height of 43"which is over 904.4.1 High Replace counter with an ADA compliant one that is no the 36"limit.The counter Is also made up of two 41"wide more than 36"In height. sections with a 1"gap in between them. 211 Town Hall Service Counter Public Woks The front counters in Public Works for the PW and Utility 904.4.1 High Replace counter with an ADA compliant one that is no _ --'---.r"` -/- side are 43'In height which is over the 36'limit The more than 36"in height. u..7 f punters are also made up of two 35'sections with a 1" I m gap In between the 212 and r Town Hall Service Counter Admin The front counter has clear foor space that extends 8" 306.2.2;306.2.3 High Replace counter with one that has clear Floor space under the counter whlchs less hn the 17-25"rquied. extending 17-25"undereath. 213 Town Hall Service Counter Clerk's The clerk counter has clearfoor space extedning only 12" 306.2.2;306.2.3 High Replace counter with one that has clear Floor space under the counter which Is less than the 17-25"required. extending 17-25"undereath. 214 Town Hall Service Counter Public Works Both front counters in the public works area have clear 306.2.2;306.2.3 High Replace counter with one that has clear Floor space foor space that extends only 8"under the counter which Is extending 17-25"undereath. less than the 17-25"requirement. 215 Town Hall Dispesing Device Breakroom The coffee maker hot water spiggott and levers are 50-51 308.3.1 Medium Replace coffee maker with one that has control levers near 1/4"above the floor which is over the 46-48"limit the bottom of the unit. 1 216 Town Hall Signs Toilet Rooms There are no signs at inaccessible toilet rooms that give 216.8 High Add signs at Inaccessible toilet rooms that give directions directions to the accessibe toilet rooms. to the accessible ones. 217 Town Hall Signs Men's xecutive toilet room The men's executive toilet room sign is o ADA compliant 703.2;703.3;703.4.2 Medium Replace sign with and ADA compliant one that is mounted and Is missing Braille and raised characters and is not on the latch side of the door. mounted on the latch side. 4 218 Town Hall Signs Women's executive toilet room There is no sign for the toilet room 703 Medium Add an ADA compliant sign to the latc side of the door for the toilet room. 219 Town Hall Signs Admin conference toilet room There is no sign for the toilet room 704 Medium Add an ADA compliant sign to the latc side of the door for the toilet room. 220 Town Hall Entry Door Men's executive toilet room The door width is only 263/4"wide. 404.2.3 High Replace door with one that has an opening of 32" minimum. 221 Town Hall Entry Door Admin conference toilet room The door width is only 261/2"wide. 404.2.3 High Replace door with one that has an opening of 32" minimum. 222 Town Hall Entry Door Men's executive toilet room The manuevenng clearance for the entry door is only 39 404.2.4 High Add an automatic door opener to the entry door. 1/2"deep which Is less than the 60"required. 223 Town Hall Entry Door Admin conference toilet room The manuevenng clearance for the entry door is only 4"to 404.2.4 High Add an automatic door opener to the entry door. the right of the door due to the toilet and Is less than the 18"required. 224 Town Hall Entry Door Admin conference toilet room The door knob is round and requires tight grasping to 404.2.7 Medium Replace handle with an ADA compliant one. operate.Not ADA compliant. 225 Town Hall Entry Door Men's executive toilet room The force required to pen the door is 7 lbs which is more 404.2.9 Medium Add an automatic door opener to the entry door. than the 5Ib limit. 226 Town Hall Entry Door Men's Executive toilet room The door closes from a 90°to 12°in 2.5 seconds which is 404.2.8.1 Medium Adjust door closer or add an automatic door less than the 5 second minimum. opener/closer. 227 Town Hall Entry Door Women's Executive Toilet Room The door closes from a 90°to 12°in 3.5 seconds which is 404.2.8.2 Medium Adjust door closer or add an automatic door less than the 5 second minimum. opener/closer. 228 Town Hall Entry Men's executive toilet room The pnvacy wall is 391/2"from the door and the end of 404.2.4 High Reconfigure walls in restroom so there is adaquate room the wall is 57 3/8"from the side wall.There is no 60"of to get Into and out of the toilet room. width to get into the restroom area. 229 Town Hall Clear Floor Space Admin Conference Toilet Room The clear floor space in the single user toilet room is 34"x 603.2.3 High Reconfigure toilet room so there is clear floor space of 30" 391/2"which is less than the 30"x 43"area needed. x 48"and/or Add sign directing to an accessible toilet 230 Town Hall Mirrors Men's executive toilet room The bottom edge of the mirror is 48 1/8"which is over the 603.3 Medium Reposition mirror so that the bottom reflecting edge is no f 40"limit. more than 40"above the Floor. I" 231 Town Hall Mirrors Admin conference toilet room The bottom edge of the mirror is 48"which is over the 40"603.3 Medium Reposition mirror so that the bottom reflecting edge is no limit more than 40"above the floor. 232 Town Hall Coat Hook Men's executive toilet room The coat hook is mounted at 671/4"from the floor on the 603.4 Low Reposition coat hook where it is a maxiumum of 48"from stall door which is over the 48"limit the ground. 233 Town Hall Coat Hook Women's executive toilet room The coat hook is mounted at 52"from the floor on the stall 604.4 Low Reposition coat hook where it is a maxiumum of 48"from door which is over the 48"limit. the ground. 234 Town Hall Coat Hook Admin conference toilet room The coat hook is mounted at 68"from the floor on the stall 605.4 Low Reposition coat hook where it is a maxiumum of 48"from door which is over the 48"limit. the ground. 235 Town Hall Lavatories Women's executive toilet room The forward approch to the lavatory is only 451/2"deep 606.2 Medium Reconfigure stall walls to allow for a forward approach of which Is less than the 48"minimum. 48"to lavatory. 236 Town Hall Lavatories Admm conference toilet room The forward approch to the lavatory is only 34"deep 607.2 Medium Reconfigure stall walls to allow for a forward approach of which Is less than the 48"minimum. 48"to lavatory. 237 Town Hall Lavatories Men's executive toilet room The clear floor space extends only 3/4"under the couner 306.2 High replce cabinet with a counter than allows for 17-25"of f which Is less than the 17-25"required. clear floor space. 238 Town Hall Lavatories Men's executive toilet room The toe clearance is 4"high X 21/2"deep which is less 306.3.3 High replce cabinet with a counter than allows for 17-25"of than the 27"height and 8"deep minimums. clear floor space. 239 Town Hall Lavatories Admin conference toilet room The toe clearance is only 11/4"deep which is less than the 306.3.3 Medium replce cabinet with a lavatory than allows for 17-25"of 8"minimum. clear floor space. 240 Town Hall Lavatories Women's executive toilet room There is no pipe insulation installed. 606.5 High Install pipe insulation. 241 Town Hall Lavatories Admin conference toilet room There is no pipe insulation installed. 606.5 High Install pipe insulation. 242 Town Hall Lavatories Admm conference toilet room The faucet handles are knobs and require tight grasping 606.4 Medium Replace faucet with an ADA compliant one,touch free and gibs of force to operate. wool be best. 243 Town Hall Water Closet Women's executive toilet room The accessible toilet crooked with the rear of the toilet 18 604.2 High Remount water closet so that it is 16-18"from the side 1/2"from th side wall while the front of the toilet is 17"on wall. the front. 244 Town Hall Water Closet Admin conference toilet room The accessible toilet is 143/4"from the side wall while the 605.2 High Remount water closet so that it is 16-18"from the side front of the toilet is 141/4"on the front. wall. 245 Town Hall Access Stall Men's executive toilet room The access stall is 35"W x 56"D which is less than the 56"W 604.3.1 high Reconfigure the stall walls so that the access stall is 5"W x x 60"D requirement. 60"D minimum. 246 Town Hall Water Closet Men's executive toilet room The water closet height is 151/2"which is less than the 17-604.4 High Replace with an ADA compliant water closet. 19"requirement. 247 Town Hall Water Closet Admin conference toilet room The water closet height is 151/2"which is less than the 17-604.4 High Replace with an ADA compliant water closet. 19"requirement. 248 Town Hall Grab Bars Women's executive toilet room The grab bar on the rear wall only extends 23"on the 604.5.2 Low Reconfigure grab bar so thatl2"extend past closed side openside of the water closet. and 24"extend past the open side. 249 Town Hall Flush Handle Admin conference toilet room The Flush handle is mounted on the closed side of the 604.6 Medium Reconfigure flush hande so hat it is on the open side of the toilet water closet. 250 Town Hall Toilet Paper Dispensers Men's and Women's Executive toilet The toilet paper dispensers are double roll dispensers. 604.7 Low Find a dispenser that allows for both rolls to be ADA rooms;Admin Conference toilet They are mounted where one roll is compliant and one roll compliant room is not.If the compliant roll is empty then the TP dispenser withnot be ADA compliant 251 Town Hall Stall Door Men's executive toilet room The stall door for the water closet is only 241/2"wide 604.8.1.2 High Reconfigure stall walls and door so that the door is 32" which Is less than the 32"minimum. wide at a minimum. 252 Town Hall Stall Door Women's executive toilet room The front approach to the stall door is only 453/4"deep 604.8.1.2 High Reconfigure stall walls so that there is 60"minimum which is less than the 60"requirement. frontapproach. 253 Town Hall Stall Door Men's executive toilet room The stall door is not self-closing. 604.8.1.2 Low Install self closing hinge on stall door. 254 Town Hall Door Admm conference toilet room The dor is not self-closing. 604.8.1.2 Low Install a closer on the door. 255 Town Hall Door Hardware Admin conference toilet room The door hardware is a knob and requires grasping to 604.8.1.2 High Replace door knob with a door handle. operate. 256 Town Hall Access Stall Women's executive toilet room The access stall width is 59 1/2"which is slightly less than 604.8.1.1 Low Reconfigure stall walls so that access stall width is 60" the 60"required. 257 Town Hall Water closet rom Admin conference toilet room The room is only 52 1/2"deep which is less than the 59" 604.8.1.1 Medium Reconfigure toilet room so there is 59"of depth. minimum for a floor mounted toilet. 258 Town Hall Accessible Route/Ramp Second floor hallway south end The ramp on the south end of the second floor hallway has 405.2 High Adjust ramp so there is a maxium slope of 5.9° a slope of 5.9.which Is greater than the 4.8.maximum. 259 Town Hall Accessible Route/Ramp Second floor hallway south end The top of the ramp is the same width as the ramp for the 405.7.2;405.7.3 Medium Limit width of ramp to 65"so the top s the same width as first 17"and then is reduced to 65"In width. the ramp. 260 Town Hall Accessible Route/Ramp Second floor hallway south end The ramp has an approximated rise above 6"and is 405.8 Low Add handrails to both side of the ramp where the gripping without handrails surface is 34-38"In height,the grinning surface iS continuous,the diameter of the handrail is adequate, extend 12"beyond the ends of the ramp. 261 Town Hall Signs Aspen Room-201 The sign text is not raised,there is no braille,and the clear 216.2;703.5;703.2; High Replace sign with and ADA compliant one that has floor space In not adequate. 703.3;703.4.2, adequate clear floor space. 703.4.13 262 Town Hall Signs Blue Spruce Room-202 The sign ten is not raised,there is no braille,and the clear 216.2;703.5;703.2; High Replace sign with and ADA compliant one that has floor space In not adequate. 703.3;703.4.2, adequate clear floor space. 703.4.13 263 Town Hall Signs Ponderosa Room-203 The sign text is not raised and there is no braille. 216.2;703.5;703.2; Medium Replace sign with and ADA compliant one. 703.3;703.4.2, 703.4.14 264 ■ Town Hall Signs Restorative Justice-On Glass Sign is a sticker on the glass door that can be difficult to 216.2;703.5;703.2; Low Leave-making sure on wall sign is ADA compliant. read with the glare.The text Is not raised and there Is no 703.3;703.4.2; braille. 703.4.15 �. 265 Town Hall Signs 204-On Glass Sign is a sticker on the glass door that can be difficult to 216.2;703.5;703.2; Low Replace with an ADA compliant room number mounted on read with the glare.The text Is not raised and there Is no 703.3;703.4.2, wall on latch side of the door. - braille. 703.4.15 265 Town Hall Signs Restorative Justice-On Wall The sign text is not raised and there is no braille.The sign 216.2;703.5;703.2; High Replace with an ADA compliant sign that is mounted at an is o setback 5"from door on wall and has 17"of clear 703.3;703.4.2, ADA compliant height(48-60")and has clear floor space -"-- floor space before ramp.Sign is also mounted too high at 703.4.16 67"which is over the 60"maximum. 266 Town Hall Signs Women's RR92 The sign does not have raised text and is mounted on the 216.2;703.5;703.2; High Replacewith an ADA complaint sign that is mounted on the push side of the door. 703.3;703.4.2, wall on the latch side of the door. 703.4.17 267 Town Hall Signs 220-On Glass The room number is mounted on the glass door with no 216.2;703.5;703.2; High Replacewith an ADA complaint room number that is raised text or braille. 703.3;703.4.2, mounted on the wall on the latch side of the door. 703.4.18 268 Town Hall Signs 230-On Glass The room number is mounted on the glass door with no 216.2;703.5;703.2; High Replacewith an ADA complaint room number that is raised text or braille. 703.3;703.4.2, mounted on the wall on the latch side of the door. 703.4.18 I- 269 Town Hall Signs Department of building safety The sign does not have raised text or braille,and part of 216.2;703.5;703.2; High Replace with an ADA compliant sign mounted at the the sign is mounted over the 60"limit at 69 5/8". 703.3;703.4.2; appropriate ADA compliant height. 703.4.19 270 111 I r Town Hall Signs North Stairway doors The sign does not have raised charecters and is mounted 216.2;703.5,703.2; Low Replacewith an ADA complaint sign that is mounted on the on the push ode of the door. 703.3;703.4.2; wall on the latch ode of the door. 703.4.20 271 Town Hall Signs Women's RR 81 The sign does not have raised text and Is mounted on the 216.2;703.5,703.2; High Replacewith an ADA complaint sign that is mounted on the push side of the door. 703.3;703.4.2; wall on the latch side of the door. 703.4.21 272 Town Hall Signs 210-On Glass The room number is a sticker on the glass door with no 216.2;703.5,703.2; High Replacewith an ADA complaint room number that is raised text or braille and can be difficult to read due to 703.3;703.4.2; mounted on the wall on the latch side of the door. glare. 703.4.22 273 Town Hall Signs Community Development The sign text is not raised,there Is no braille,and the sign 216.2;703.5,703.2; High Replacewith an ADA complaint sign that is mounted on the is mounted on the hinge side of the door over the 703.3;703.4.2; wall on the latch side of the door at an ADA compliant maximum height of 60" 703.4.23 height. I P. _ 274 Town Hall Signs Community Development Paper Sign directing building permits to room 230 is printed 216.2;703.5,703.2; High Replace with an ADA compliant sign with raised text and Directional Sign paper with no raised text or braille and is mounted on the 703.3;703.4.2; braille. pull side of the door. 703.4.24 , 275 Town Hall Signs Network Services The sign text is not raised and has no braille.The sign Is 216.2;703.5,703.2; High Replace with an ADA compliant sign that Is located with blocked by IT storage cabinets 703.3;703.4.2; clear floor space. 703.4.25 276 Town Hall Signs Elevator room The sign Is a printed piece of paper with no raised 216.2;703.5,703.2; High charecters or braille and clear floor space. 703.3;703.4.2; 703.4.26 277 Town Hall Signs Community Development director Sign is flat with no braille and is mounted over the 216.2;703.5,703.2; High Replace with an ADA compliant sign on the latch side of doorway. 703.3;703.4.2; the doorway. 703.4.27 !A r 278 1'i Town Hall Signs Men's 82 Sign text is not raised and Is mounted on push side of the 216.2;703.5,703.2; High Replace sign with and Ada complaint one mounted on the door. 703.3;703.4.2; latch side of the door 703.4.28 279 Town Hall Signs Emergency Exit 2nd floor Door There are two signs and neither has raised text or braille. 216.2;703.5;703.2; High Replace with an ADA compliant sign mounted on the latch Both are mounted on the door on the push side.Door 703.3;703.4.2; side of the door. opens out to a large step that leads to deck and stairwell. 703.4.29 280 Town Hall Signs Caution floor Change The sign is mounted on one side of the hall with no raised 216.2;703.5;703.2; High Replace with an ADA compliant sign and mount on both text or braille. 703.3;703.4.2, sides of the hall. 703.4.30 281 Town Hall Signs Community Development Copy Only the 4 has braille the rest of the sign has no raised text 216.2;703.5;703.2; High Replace sign with an ADA compliant one wour- room-"Meeting Room 4" or braille 703.3;703.4.2, 11. 703.4.31 _ 282 n _ Town Hall Signs Elevator Sign-Use stairs in case of Sign has no raised text or braille. 216.2;703.5;703.2; High Replace with ADA compliant sign. fire 703.3;703.4.2; I. 703.4.32 283 Town Hall Doors Community Devlopment Glass door width is 313/4". 404.2.3 High — 284 - .. MI Town Hall Doors Community Development The manuvenng space is 171/2"wide due to the file 404.2.4 High Adjust file cabinets so that the manuevenng space is 18" cabinet. wide - 285 lip I IF Town Hall Doors 201 The manuevenng space is 121/2"wide and only 123/4" 404.2.4 High Add an automatic door opener to the entry door. - 7• deep before getting Into 202 door swing. r C 286 f V Town Hall Doors 202 The manuevenng space is 213/4"wide but only 123/4" 404.2.4 High Add an automatic door opener to the entry door. deep before the door swing from 201. -- I 287 Town Hall Water Fountains second floor hallway-both The clear floor space is only 141/2"deep which is less than 306.2.2;306.2.3; High Replace with ADA compliant water fountains. Pir the 17"-25"recommended range.The depth of the water 308.2;602.4;602.5 _. fountain is 141/2"-14 3/4"which is less than the 20-25" ie range recommended.The spout is located at 441/2"and -'III4"( ' � 288 411/4"which are both higher than the 36"maximum.The ,i ii spout is also 121/4"-121/2"from the rear which is less 1 than the 15"minimum. W /•/ Town of Estes Park Public Works/Facilities 2022 Facilities Worksheet EP Assess Building Address Interior Public Works Parking Structure 691 N. St. Vrain Ave. X Fleet Services (Now Streets Shop) 575 Elm Road X Fish Hatchery 1 1707 Fish Hatchery Rd. X Murray Duplex 1 & 2 231 E. Riverside Dr. Stanley House 179 Stanley Circle Dr. X Parks Shop 600 Big Thompson Ave. X Performance Park RR 417 W. Elkhorn Ave. X Fish Hatchery 2 1703 Fish Hatchery Rd. Tregent Park Restroom 293 W. Elkhorn Ave. X Fish Hatchery 3 1705 Fish Hatchery Rd. X Hydro House 1754 Fish Hatchery Rd. X Moraine Restroom 215 Moraine Ave. X Riverside Restroom 110 E. Riverside Dr. X Picnic Shelter 500 Big Thompson Ave. X Parks Dept-Greenhouse 600 Big Thompson Ave. X Garage/Rental 179 Stanley Circle Dr. x Cabin/Rental 179 Stanley Circle Dr. x Sand/Salt Storage 650 Elm Road Transit Hub Shelter 1209 Manford Ave. General Town Hall 170 MacGregor Ave. X Records Storage 1707 Fish Hatchery Rd. REO Garage/PD 1708 Fish Hatchery Rd. Youth Center Building 300 Community Drive Old Fish Hatchery Park RR 1700 Fish Hatchery Rd. Storage Building 1701 Fish Hatchery Rd. Storage Building 1709/1711 Fish Hatchery Rd. PD Storage Cabin 170 MacGregor Ave. ComServices Conference Center 201 S. St. Vrain Ave. Bond Park 170 MacGregor Ave.? X Event Center 1125 Rooftop Way X Pavilion 1115 Rooftop Way X Fairgrounds/Rodeo Grounds (Grandstands) 1209 Manford Ave. X Visitor Center 500 Big Thompson Ave. X Performance Park 417 W. Elkhorn Ave. X O'Connor Pavilion 1700 Fish Hatchery Rd. not inside r Stable A 1209 Manford Ave. Stable D 1209 Manford Ave. Stable G 1209 Manford Ave. 'Stable K 1209 Manford Ave. Stable L 1209 Manford Ave. 'Stable M 1209 Manford Ave. Stable Tack Stall B 1209 Manford Ave. 'Stable Tack Stall F 1209 Manford Ave. Stable Tack Stall H 1209 Manford Ave. Stable Tack Stall I 1209 Manford Ave. Stable Tack Stall J 1209 Manford Ave. Exhibitor's Office/ Fairs & Events Only 1209 Manford Ave. Announcer Booth C 1209 Manford Ave. Shoeing Barn 1209 Manford Ave. Stable V 1209 Manford Ave. Ticket Booth 1209 Manford Ave. Maintenance Shop 1209 Manford Ave. Tool House 1209 Manford Ave. Chutes& Corrals 1209 Manford Ave. Roping Pens& Chutes 1209 Manford Ave. Stable U 1209 Manford Ave. Portable Judges Stand 1209 Manford Ave. Ticket Booth 1209 Manford Ave. X Announcer's Booth 1209 Manford Ave. Stable T 1209 Manford Ave. Exhibit Building 1209 Manford Ave. X Hay Barn 1209 Manford Ave. Show Office 1209 Manford Ave. X Horse Barn W 1209 Manford Ave. X 'Stable E 1209 Manford Ave. Log Building@EC Entrance-NPS Stanley Park Log Building@EC Entrance-NPS#2 Stanley Park Manager's Office Stanley Park X Stanley Park Fairgrounds-Restrooms 1209 Manford Ave. X CulServices Museum Annex 220 Fourth St. X Museum 200 Fourth St. X Museum Hydroplant 1750 Fish Hatchery Rd. X Museum Workshop 200 4th Street Rocky Mountain NP Museum 200 4th Street X Log Cabin - Museum (Cobb-Macdonald) 200 4th Street X Birch Cabin-Education Building 324 MacGregor Ave. Education 324 MacGregor Ave. Education (Ruins) 324 MacGregor Ave. X Old Fish Hatchery Power Plant-Museum Office 1746 Fish Hatchery Rod. X P&C Dekker Light & Power 615 Elm Rd. X Broadband 1180 Woodstock Dr. x Light & Power Storage 680 Elm Rd. Substation Shop 2009 Mary's Lake Road Lake Estes Substation 875 N. St. Vrain Ave. Electrical Substation Mary's Lake Water Mary's Lake WTF 899 Lakewood Ct. Glacier Creek WTF 480 Caring Lane Glacier Creek Water Plant-Gatehouse/Headworks Mill Creek Road/480 Caring Lane Water Department (Now Fleet Services) 577 Elm Road X Mary's Lake Raw Water Pump Station Mary's Lake New Water Shop 1360 Brook Drive Crystal Water Plant-Chemical Storage Carriage Hills Kiowa Estates Pump House 450 Kiowa Dr. Thunder Mountain Pump House 2 Mile SW on Spur 66 Fall River Estates Pump House 2000 Fall River Road Booster Station Fall River Road & Fall River Court Prospect Estates Pump House 1660 Prospect Estates Dr. Water SCADA/Tank Level Monitoring Site 1001 Prospect Mountain Rd. Big Thompson Filter Building 1065 Prospect Mountain Rd. Municipal &SCADA Base Station Prospect Mountain Road Storage Prospect Mountain Road ments Completed Assessment Survey Dates IExterior I Roof X X 5/26/2020; 8/16/2020 X 1/28/2021 X X 7/1/2020; 12/11/2020 Building Demolished X X 7/16/2019 X 2/26/2020 X X 1/21/2020; 5/26/2020; 7/21/2020; 10/8/2020 X X 1/21/2020; 5/28/2020; 7/21/2020; 10/8/2020 X X 7/7/2020; 12/11/2020 X X 6/24/2020; 1/19/2022 X X 5/26/2020; 7/21/2020; 10/8/2020 X X 1/21/2020; 5/26/2020; 7/21/2020; 10/9/2020 X 5/26/2020; 8/18/2020 Shelter removed, parks working of X 2/26/2020 x x 7/16/2019 x x 7/16/2019 X X 5/26/2020; 9/17/2020 X X 6/23/2020 X X 3/18/2020; 10/9/2020 X X 3/18/2020; 9/30/2020 X X 3/18/2020; 9/30/2020 X X 5/27/2020; 8/26/2020 X X 5/26/2020 X X 6/24/2020 X 3/18/2020 X X 3/18/2020 X X 3/18/2020 X X 3/18/2020; 9/30/2020 X X 3/18/2020 X 3/18/2020 X X 7/1/2020 X X 7/1/2020 X X 6/24/2020 X X 7/1/2020 X X 7/1/2020 X X 7/1/2020 X X 6/16/2020 X X 6/16/2020 X X 6/16/2020 X X 6/24/2020 X X 5/21/2021 x x 7/17/2019 (pre reno) X X 2/3/2021 1 replacement 2/15/22 KM Lena., Fwd. 13.10.104„ Bk010e1011013 1.20 40 3534303 103 333,37 n 202.16,0629123 3333.6_1.00. .30430,0728123 20230416_1.33. 202.36,0746. 201.16_1.5.0 riZ171:71;67:=1:::"'"'""'e'''" :::2744=1419=::6"'" 1 40 3534503 9105 3237737 2.1203 303130645 XIS 2 2035 important 51-500 32. 32.026 weessIblenarkIng 9.20 32.5300 038734 20330416_130646. ::e4ernalneln:rel4TP:=1:1:=1:1=217::Ingtelg:673tH="'"'"''er"h"' SO 0130. 40 3736367 125 3333030 30 3' Oren 3/343023 Play.52.037039 ..16,4157. l'nsek:rgr=le:1=45'"ell'"'"'rn""'""'r'e"""'"'"rn"'"""'"'th""'" 1 40 3736367 303 523303S 1/.025 P.P.9.120 037260 9 Wea 2103103 357860 .3 parks employe„..26.23.W. 3035. 15,0415,43213.0 30333433_1341,100 :n7e=k6::YY9r"t'eP*'re'""' 526==:45:4147s,lem Sur.43.41.010, SO Player, Play. .24,3051 22.12.13.1.3. 40 3736367 :r'n',.7,;:=1.15,1,t=d''''"'—'----"le"'''"""'''""ac''nd "en Play.52.037831 Way..3102 03.3 Play,.5,3.037833 202.16,3945123 202.16_1.19. .30116,4121. syyra,k64..6,,wpg, '2=:::41;17411t7esT6 3 526==1.3 SO 40 3736367 9105 523303S 15. 057. 4 SO W park MO 40 3736367 OPen 8576. :=H=0":;:y4rPrIll=1=0::44=54'472:::67:13====1:7361: .30415_333934,3 5 SO 40 3736367 221.021200 2 4 moms. 057363 20230416,2345120 6 SO 40 3735333 'S Orh2734r79H1=4 117Ikeer'he"'"e"'"'e Oren eakIn Is en the 11.10 1/1/2026 find,857853 FM"'"' 20230416 101732 202204.120.341332 20230416,01626. 1023.6,1519. Spam envy nee they ser., 5=e27::::ZertZe:r$a 40 3774343 305 3203730 S. 52.0 40230415_1157141N 20230.6,15719. Bo.Park Genera!F44404296 NA 40 3774943 103 3303730 Oren $500 5.00 3/343026 Walkways 520.057035 Walkways 6.232 05.5 20230416_1„738. 202.16_11.1. 2430313ark 40 3774343 5130 2300 I/3/2035 Walk:.5261.57256 9 Walkways.10.857352 le.1.0.11,330.3.22,3.113. .3041.35563. 3 Beeni Park 020 40 3,4543 125 3333738 30" Oren 4/4/2025 Wallman Fn..857850 Walkways F..05.0 2023.16,5306. 2023.6,5831. wwwww a 393.3 ,e..w,,....d 991..331,... .. w,n.3 40333037311 �..,..,p.,,.,.b,m..e. �.. 13.11.1153.3.933.11.11.43.31333.11 2033a..93101710 Ha. =,o SILO 33 ou,.,.w.,....d.,.,.,, M.d.,., M.d.,., .331.31.133 734.111.19333.31.93 20 3.8 0000 2.90. NA 403768726 V,520.1 887909• 887109• 202.2.301202018 20200416.621.6 6 26.8.18.0,01 88800.0688„Ing „„888198 Slo„89.88 NA 10 9068726 EIS 520.1 867620 852. 2023602.32.086 ,226116.2312.8 NA 403768726 105 5206284 nonov lamb. Oven 2560 5.0 857221 2,20416.2207266 10 9768,6 .2 5206. „50 867922 852912 =7=;lag:Z=1=7:8:8:=878==n9="' 2023,26,264.8 20260416,2606198 9 8.086 89868„, 0.00016 88960 68.81116.0.10 .0„A. 400,8,6 06en 22 SCC 8576. 202.2.32726288 20 40 3768226 286 5206. 55000 867624 852914 20230126,68202.8 2026021.0882.96 20 NA NA 403768726 Oven 202.6 130646 ma 40 3768,6 6068 025 1.1025 1.800m„ 8879. aonona_084513.8 :=7171:1="::::===7,2':::=ZoTro71::e"' Est„ra.„ Less...604,1w uok 403768726 205 S..40" Oven 25 0, „600 .2026 nestroorm 20.1,084526. 24 1.1 NA 10 MS. .2 5208.22" „, 52 2020012.84538188 68. 25 .6.Du 403768,6 52.6.9„a... 590 275 9.2025 nem.,fintl..81357,20 20.1i3,1526113, °'" "" " °"'"" NA 40 3768226 520826.2" ANG3on z 168M1 2020012.84667188 27 20 Estes ra.„Piavemuntl oisbnce nom Tod, 40 3768726 5206284 2" Oven 2O10..6.17 amon,0846i31. Tc'etr=":17:::=:=Ilhe:71==mte4=7:5==e :==eu':=11n12=e7e=271Z:::42:::::wrtegIZZ:r"'" 3„mi.8 oii.wm,.a .a so mans ,o::,<„ss Faded.. ,.a,psi.o.,�i..uai.ie.ai.✓�.w.aw.a..�,,,ia..,.dii.oa.�a..ai...ae� w.. nem.....,asi.o.wre.,.ii,..d,cces. 2010.n22.50:.33 221 m:o ssoo 90 5180nee ...L. NA 40 37.799 -105 514.5 53" OPen 201.1.502 6 F. . 85.6. 857936. 10130416_1.4.168 202304,1446,128 5 50 $61911.9$5 Lew NA 40.3180790 405 5111165 52" 2010.1502.6 Nigh 50 858000- .80, 7:571===177:17:1=====. 20230616,44820. 102304,1.04. 6 90 CP.. 1.36.6„ 40 37.799 Oren 50 1,62025 Annenstle 651.-0.8 85800, 201.416_14734468 7 50 F.Per..901.1 40.3180790 50 8580. 85.2- 858002- 20230516,45039161 20250416,4520349 2023041,144754. 8 rerr=1:1:""' "n'.'''"'" 40 3.0074 -PM 5217528 9500 5750 858003- 858003- 101.416,494.8 20230416_134945. 101.416,5015468 202.16_13501M. 11.1 1 0.11 ON 611.10161 MUM.ern elMe plan AmeMble Routes Amers1.89. M 1111.„111 40.3760070 516500 5.0 16163037 Acenalle 1.1.510668 A.m.Poute.51.19 A...1.1.510.6 AccessnalePoute..11. O. 8580. 859004- 858004- 85.4- 1‘11===='"'""'''"'"'"''''t"''''''""rn e'e'"e""'"da"''' 20230056,35506.1611 20250416,5513449 20230016,35156.161 20250416,55251108 3 :5==w' ""e"'" F....65.9 40 3760094 -105 5217528 6"sterl OPen 550 $95 858005• 858005. 10130416,35525. 202304,135318-128 10.09.91,11111c„re.and Mtlewants.and publIntransperlann.......50111.1181n9 or.1.1.1 3 . M OlerneMal 40.3760070 50 858006- 20230016,3521.8 spaces Mat am antn„ame. 4 :5==w' "'''''"'e PM.. Ancessible Poute nerpe../ Pope NA 40 3760071 -105 5217528 """'an'"'"'""""'"'"'""2 P'rw"t Oren 91. 51.500 l'2°27'"'''"*.j"'"'" ''''''"'"'1'n""'" 35500n- 858009- .25591.5-15.91168 9$2.619-155515128 5 MM. Pope . 40.3160. -105 5217528 51.500 56500 Me mmm8LopeOnes not me.. 858010- 858010- 20230016,35,50.160 X0330416 235957. 6 rerr's:1:1:7' k"'""n 5' "n-"'"t Ac"'""n' "n''''' ''''''' . 40 3760074 OPm 525 950 855007- 858007. 2023011591355001113 20230416,35403. 7 40.3760070 5750 52. Ance....05 858008- 8590. 10230016,35500161 20250416_155.1. 8 MP 403..15 -105 53.746 VS. 85801, 85801, 858011. 85801, 8580, 858011. 202.416,04520168 20230416_1.52-5-6, 101.416,04635468 20230416 104638428 .230416,047.1113 20230416 104715428 OPP., 1 50 7122 7/2512.2 Garden 740.5 bend 40 37E6915 105 53.746 .17en 858012. 858012 707.416_104808220 2025041.04013.8 SO Gann....ads 20 X. 40 378.15 .105 53.746 aseola a5.013 202.16,4849. 202.16_1.53. 3 40 3786915 105 53.746 04757 5.0 27. 20230426_2049271. .20230416_204927.8 '1=5:::05':177:37:4'571.;n0=0.7:::=1:4:07 9'"h" sh'""""" a p„ 423 3772979 .040 S750 .1027.0.22701202.75.220.13 850015 20230426_1125451. 1 2522.04.51.7 2.0.4.a.. 57.5.85.07 40 3772979 105 5293258 0 0435 The 4.2.0 patn 71.5.47„oss 21.52 7.42."2545 222 570. .800 858016. 858016. 858016. 858016. 707.416_111.827100 20250416_111.128 707.416_11184125.2 202.416_1110.728 .275221015.7552 .020110.775 40 377.79 .040 1147147==07"P ',:r7" " .50 1300 1.026.0.277011.2475.21.1.12 0.52024.0•.278 .0017 858017 2023.26,127542. 1023.6,1711.0% 3 25225.4.5.. 125 40 3772979 105 5293250 26 25" C4757 102.527.2.50.52.5.45.5287.255774770 7010.05.7 2 10.5.02 5.0 075. 70/7026 82.0250.2 fir..858037 202304,„00301. a Sle„nkrn.M14 3772979 iOS 52500 nancl..15,leeprotedwn etc, 707.416_111.1220 20230416_111455128 75.1 5 51.2 40 3772979 105 5293258 SI 500 27000 85801, 858018 70230416_111007258 20230416_111012 128 6 aa 377.79 405 5293. Nen LIAM 84.42115 84752215151.78 20.08 850019 e5.019 1115 crass 215.7 51152.2211715 park!.2151151..5 mess A.m.natexceed 2023.26_1120462. 102.16,..52.114 50 .3772979 105 5293250 2 95% 858020. 858020. 70.0416_1111257. 20230416_211170.8 SO 0084 40 3772979 .105 52.258 440 858021 85.21 2023.16.243.2 10230.116,151. SO Pa.ne Off,reet sccewele awe.A.sie 40 3772979 105 5293250 858023- 858023. 70230416.1227727.2 202.416_111277.8 10 Palm.-Off Street 6644661,14 gala. gaii.s.ace 5.664ge NA 40 3.2979 -109 9293298 No sign 350 S. 1/1/2025 44.66116 ga.iiii-.riding 8580.. 20230416_112148.8 11 . M..= glorie 40 3.2679 105 5293258 SI 500 22.660 .8029- 656025- 2023.16_141n6188 20230416,18614611 12 5ierigee NA 40 3.2979 -109 9293298 No,.sliel.6 S. S. 1/1/2025 44.661,14 ga.rig-.Wine 858026. 20230416_141750.8 13 wail,. . NA 40 3.2679 install new 616,68 that Inc1868616815A symbol, 20104..216 4.10..High ,50 S75 1/1.025 11.1room.86.ing 8.027. Braille 664164.¢...., 7031 20220416_105.4188 Inches 60 10 IziNtory Pim... . NA 40 3222979 -109 9293298 3475" 5290 $300 1/1/2028 Pesinsim-fintli.0560211- 20230416_106422.1. 15 SO 40 3772979 .105 5293.8 10" The toilet paper b n6118.41166 wilAin.e.inplient range 18(.816116st.. 20.00.6430 2 High . 1/1/2025 11.reem.iintling 8.026. 20260416_105998.8 rce:=SriZiresnrM1=6.:Z=Nnscilh0:79==ida'nde====thhes Mi.News.Nell.t.14.1861 belinil grab bars Pipmsers slug WI.da Velhata,n1.ideiNerysis.st .61.-ComparOnent Mars HansiN 40 3.2979 625 $50 1/1/2025 Pestromis-fintli.056030- .23.16_106.1M 17 SO NA 40 3772979 105 5293258 50" 2010,0.316 2 1 High . 1/1/1025 fiestroom.iintling 8.031. 20260416_105536.8 50 NA 40 3.2979 -109 9293298 35. 2010,10.902 6 Huh . 1/1/2025 Remo..-fintli.056032- 20230416_106701.1. 19 wail,. . NA 40 3.2676 install new,ignage.at 1841846.6415A si.biS. 2010A0.216 4.10..High ,50 $75 898234- 707,0016 4046.108 Indy OW, oo 444o( NA NA 40 3.2979 Oven 625 550 1/1/2025 Pemoorim-fintli.656034- 20230.6_1.7581. 21 SO Bab,Changing Sable -roe NINA 66. NA .3222979 .5 52.258 37" Lower the baby changing table 2010 00.912 3 High . 1/1/2025 neslreconi.iintling 8.036. 20260416_105948.8 22 50 CAA 1,01,11NNO1 NA NA NO 3772979 ANS 5293250 5, 45,44 the coal.621, 201040.308 2 1 High SO 1/.2025 Pes..866-fintli.056038- 20230416_10665.61, 23 3288824 212 E.,...8,3,6 HP 64 40_3765547 S.. 57.. 8.608. ass., mem. ass., 3033041.13315. 2023..naasom 30330415_113955. 202304.11295.8 1 T.... 2.25.0.62.5.21 ...le neo. Hantlrell 22122186 NA HP 40 3.547 -I.52...... 512928.2.1.22111.22101.851828.8.8122828.0...1 21.2. .500 51.600 1.2027 pecessiple pocte 21.106 asasos acoama_moloJoa a Tie... 40 3765547 -105 sassese or 575 51. .3 man. 10230415_112.9. 3 .822121181.282 Pa2221102 210015 Clung.212.21. in ANN Or Greater 8225122 40 3768547 .59.9°1. Gri..........112.21.182215 aoloAoAsaoaa.aoloAoAs AaN ANN 51. 1/1.26 Paggelle peute Finelog acoacaNa_musJoa a M SO Tie... 8.8962 NAN .0220.86 UP 40 37.547 -105 5255896 63. . high and.222881221 by.trash to asma. 10330415_113137. 5 i.e.. <6.242.2 2.2.8 3. . . 40 3768547 405.65808 ....0, VV.,P2222611215 peute 21.86 Accessible..-21.8 .3.26,3109. 10230416,3414. 6 Tie... 5.62 . 40 3765547 550 $35 42622116 29.06.00i. ma, 90230415_11.25. 7 SO Par..-Oil Street .2221.55.6 P.n.. 2121.2 . 40 3768547 ....8 trash.5.22.2.2221215 2010.45.2 2.22108 High 50 1/1/1025 222.261168 Parking-21.08 asasaa- .3.26_12.9. a Tie... 29.06-...et 42222116 29.06 29.226102 40 3755547 26222228 the 89.069282 200...emu. MO ADA,.Sr 201.1.,F. $.0 5500 1.22015 422.16..08-1.08 Lot .2.4 sae.. acoama_nasaama A 2521.6•021.222 ...le Pa.. 99.8.. .6 Punning-.mt. . 40 3768547 405.65.8 0.0.5 The running 2.462.21inensioni....9211.5821.22222.42.12214 SI.. 51.000 UV.,2.22611218 Pa..-21.86 .82.12.21.21.03 2023.26_113531. 10230416_21.5.5 10 MEM Tie... gar.-021.802 4222211¢... P... 5.. 40 37.547 -105 5255898 WO 5750 858.. 8886.- 30330415_11.5. 202.16_11.51. 11 50 iregent Park iellat antl.hing 20.2 11.20.2 Sign-Wall 121.216 . . 40 37.547 405.65.8 Nocalmonaoar No 1/1/1025 21.25.2-51.1.88..- aoaaona_ceaus. n.Cantracted 62.1 Braille shallbeine 2521258.1.2.2 a.shell he.8268.1.22.3/81.8.a 12 12162821.1118...2 Tie... 10.1-502986.922 0.2 ... 40 37.547 1010.45.4 6 11 Hi. 525 S. 00250.0 083.61. 13 Trager.<Part Less...0 inme5 NA 40 2265542 yo,„,a,y4,„ 550. 52.500 60 wetn for tne accesa.Ram compartment zonom_oa35351oe ',"."",,,t7:=7:::="'—'-'"'"'`'dem"'"'"""'"°""""'"`"'"" . Tolle tart to Walla Ranttion . NA 10 5755542 105 5505058 52.. Polocatethe to.ro that It Is between 1St 1St.m 2010 SOAS NO 2 important 5520 SI 000 252/5056 postroom.floY.8515675 2023011,055555105 me emedne retne..mun below IS Inch.from the side wall 15 50 iregent Part 40 2265542 105 5555090 06 2010A.5 504 7 Hr55 50 1/155055 Pettroono 5.0thos55.20 202301,0.n log Tetatt:ert:;ren========s1=== ereVZZ=Zetr=rerer:17;erra=necnefs==vrte:erer'" le Lavatory Om Heel . NA 10 57055.17 405 556585S 35 The top.22 orNe Lust,Is Moll. L.=lay:77;that OW,or the slok rho 2012,045 Mb 2 I noorlant 52 502 5.2 COO 1/2/5056 n....Hod.858680 20220115_055625155 :==°::::t°=:='"Tet:Z":0:'''"'"°'''''''"'""°—""''''''' 12 Trager.<Part Lavatory . . 405.5542 550 525 562.65055 PetWooror Hod..055.1 xonom_o..alog la So s.wan . NA 40 3255547 Reboots the restroom alp to Ne latch oltle of the 20156065215 2 Holt Or I/2/2025 nestrocoo Hod.8515686 20250115_0824450.5 2'.75'5'.===17e=r'Y'arr7=1==orl'578V====rs' 10 t5.5.t........' iregent Part Toler c...part,...,t .,,, .. 40 2265542 $55 550 1/155055 Pettroono 5.0.2.5,55,45 zonom_omos log zo Ural Corapartrnent wao, Less than 611incher NA .10 3205542 105 556505S as 5 WOO S7 mo 252/5056 portrooms.ilnY.8515651. 20250115_05552,05 :::`,.=:::=1::::::=7;',7=7.7::217,==="'' 51 iregent Part iodetto wall or Parwon NA NA 40 2265542 105 5255090 52 5500 $5.000 1/155026 Pettroono 5.0.2.5 55.5, the st.vrall or portItion wall 20230252_05323SW 52 50 403765567 405 5565808 O. net,.pa,5 not Insulted Lawn 02e cornount ranae In rront or them. HID POPS NO 2 He SO zoz,ona_c.ao5lps ti......na.b.c.tee belind grab bars Dispeosers slvall not 56 ors ttoregatoontrols tleOreivor that 53 itagent Part Lamy P.o Oro. . NA art 2765542 105 5.555090 3555 O:76.relV'at'''''"'' '''''''''' '""r''' 5,5. S5.000 562.65056 Pertrooror fird...35.01. xonom_oanaslog 5.1 . NA .10 3205542 install plot InsulatIon on the draln and...Hoes 2010.AS Mb 5 5,5 550 S25 I/1/2025 nestrocoo Rodin,8515701 zoz,on,o.asms =7:r7=t:::°„..=====zrr'"'"'"'"'''""'"t 55 50 iregent Part NA 403765512 5°5 5.5.3.''" 2010•13.902 5 Firyn SO 1/155055 itattroorar 5.0thos 555707 zonom_oa.os log ;:::::"'"'''.'"...”....",. ......,,n,,,es.a.............n...,„ ze $0 GeNeoal-Exceeds ON NA 40,627.2 -205 52.52 6. net exceed SA NAM, 85872, 20220426,2741Aos 20220416_2227,128 2762742 .220 2206022 rrect 51,S. 1/1/2026 Acceselpie Route FIndlo2 SulAce 850721- Finding Number evaluation Title croup TV. suhtvpm Subtype3 Latitude Longitude Finding As Built Status Recommendation Barrier Standard Barrier Priority Budget Low Budget High Est Remediation Date Notes Photo 1 photo 2 Photo 3 pnosn n The shared use path is not wide enough sharedSince the use path issig designed for two way travel,is 650s6/ft ive Pedestnan Access Routes The continuous clear width of pedestrian access routes shall be So oft minimum exclus of the width of the mended that the shared use path is at least ldt wide (Cost includes removal and shared Use Path 5g829700- Shared Use Path-Finding 829T00- 2 ADA Evaluation (PAR) Shared Use Path Big Thompson Ave Continuous Width 120 minimum NA NA 0032979 105.5132 curb 96 Open Increase the width of the shared use path 2011 PROWAG R302 3 03 5 5290,000 5360,000 1/1/2033-1/1/2038 replacement of existing ashpah)Fmtling_638o89817111R150 042mg .6,6380898123122 093 mg The cross slope of the curb amp is greater than 2% Pedestnan Access Routes WAh Vield or Mop Perpendicular or Dalton br p to provide a Cross sl pe grade less than Path-Finding819To9- Shared Use Finding829TOT• DA 5 A Evaluation (PAR) Shared Use Path &g TM1ompson Ave Curb Ramp Slope Cross Controls 25 p 603802] 10551 cross slope of curb ramps blended taib nzons and turning spaces shall be 2 percent maximum 550%Open equa to 2%cur 2011 PROWAG R30053 193CR 53,000 53,500 1/1/2033-1/1/2038 Fin g_ 90 08981 _ 89 3.Ipg Finding_63500190995 60Tjpg The 30 inches minimum 1y08 aches minimum clear Rum space required at the pushbutton is consistent with the grade of the adjacent pedestrian access route Accessible Pedestnan Signal Slope-Parallel to the Changes in level are not permitted at required clear floor or ground space except that slopes not steeper than Regade concrete at the accessible pedestrian signal so that the Shared Use Path-Finding 829208- Shared Use Path-Finding 829T08- 6 ADA Evaluation (APS) Shared Use Path Big Thompson ale Clear Floor Space Pedestrian Access Route NA NA 0038025 -105 51 68 shall be permitted 880%Open running and cross slope do not exceed 2% 2011 PROWAG RM02 0.3 5 51,000 51,500 1/1/2033-1/1/2038 Finding_6380898199029]7B.IP5 Finding_6380898200006 5121pg minimum clear flomspace required at the pushbutton is consistent with Me grade of the adracent pedestrian access route (A Slope-Parallel the a rmitted at required clear floor or ground space except Mat slopes not steeper than th gads concrete at e accessible pedestrian signal so that the Path-Finding819T09- Shared Use Path•Finding 029700• 9 ADA Evaluation (PPSS) le Pedestrian Sign to Use Path BigiM1Dmpson Ave tar Floor Space Pedestnan Access Route NA NA 4038031 1055120108 shall be permitted 605%Open running and cross slope do not exceed 2% 2011 FROMM R0002 D35 51,000 51,5001/1/2033-1/1/2038 Fin g_ 089820) _ 31Pg Fin6,6380898208202760 jpg ' ■ The cross slope of the curb amp G greater than 2%. Pedestnan Access Romes With`held or Stop Perpendicular or Diagonal curb ramp to provide a cross slope grade less than or Shared Use Path-Finding 829210- Shared Use Path-Finding 829T10- 8 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Curb Ram, Slope-Crass Controls Ramp 0038029 -105.5123 The cross slope of curb ramps blended tmmtions and turning spaces shall be 2 percent maximum 10%Open equal to 2% 2011 PROW.R3005 3 D3•CR $3,000 $3,500 1/1/2033-1/1/2038 Finding_6380e9821.6159 68T.mg Findmg_6380898216762 022 mg The 30 inches minimum 1,8 an floor space required at the pushbutton is not flat(2%or 1 08 maximum slope)Perpendlcularzto Me Greet Slope•Perpendicular to Accessible Pedestrian Sign Pedestrian Access not in level are n GermAtea at required clear floor or ground space except that slopes not steeper than th gads concrete at e accessible pedestrian signal so that the Path-Finding 819711- Shared Use Path•Finding...1• 9 ADA Evaluation (PPS) Shared Use Path Big Thompson Ave Clear Floor Space Route NA NA 0038031 1055123108 shall be permitted 950%Open running and Cross slope do not exceed 29.6 2011 PRO WAG R0002 D35 51,000 $1,500 1/1/1033-1/1/2038 Fin g_ 98218 _ 11Pg Finding_6380898219306685jpg 1 The cross slope of the pedestrian access route is excessive Pedestnan Access Romes ove and replacethemzting walkway Mat has anexrezzive Shared Use Path-Finding 829212- Shared Use Path-Finding 829T12- 10 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Slope•Cross NA NA NA 0038032 1055123 The crass slope of pedestrian access routes shall be t percent maximum NEEm 696Open cross slope 2011 PROW.R302 6 D35 $1,600 $.00 1/1/2033-1/1/2038 20xe,160sq/ft Finding_6380898220109192mg Finding_638089822092103 mg The surface of Me pedestrian access route has openings greater than 1/2 inch Pedestnan Access Routes Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm(05 in). inulbde loMtianz m Path-Finding 819713- Shared Use Path•Finding 829213 sePath-Finding 829713- Shared Use Path•Findinge29n3.diameter11 ADA Evaluation (PAR) :1 : Big Thpson Ave Surce Horizontal Openings Greater Than l/2Inch NA 0038041 1055121 dmeter te opeW530293 DS5 5250 :::: 2020-1/1/202] Fos g_cong walkway that has an excess ore Sharetl Useth Bg Thompson Ave .1)C.. • NA 0038091 1055111 The crass slope of pedestrian access routes shall be t percent maximum 855%Open cross lope 2011 PROMS R3026 D35 0,600 2033-1/1/2038 120xe,960z6/ft Fnding_6380898239236216.mg Findmg_63808982398621061ps Fin g_ 98200 _ 2.mg Findmg_63808982609006271pg The running slope of pedestrian access route exceeds the general grade of the adjacent street of highway n Access Routes Within Street or Hwy pedestrian within highwayrightrof-w the grade of and replacethe existing walkway that has an excess Path-F Shared Use Finding 829216• ADA Evaluation IPAR)tna Shared Use Path Big Thomoson Ave Slope Running(Grade) R NA 105512 pedestrian access routes shall net exceed the general established for the adjacent street or highway 1385 p running slope D35 50,000 $12,0001/1/2033-1/1/2038 x8,800sq/ft Fm g_ 0898280 95jpg6 F,nding_6380898281738520 jpg 1. The detectable warning G missing at the curb amp '2 ' _]00 Pedestnan Access Rwttes Curb ramps shall have a detectable warning that ertentls the full width of Me curb amp excluding the flared stall an ADA<omDliant detectable warning zurfare that extends Shared Use Path-Finding 829219- 15 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Curb Ramp Detectable Wamingz Mizang NA 0038009 105512 sides 20 inch minimum m the direction of travel South of VMa th Open thefull widthofthe the ztreetcrossng atthe shareduse peth 2011 PROWAG R208] DS CR $350 WO 1/1/2033-1/1/2038 Finding_6380898290359 626mg The s slope of Me Remove and PedestnanAccesx Routes Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0038152 1055009 The pedestrian s slope of pedestriann access access excessive routes Mal l all be 2c percent maximum 025%Open cross slope `place the existing y tM1asanexcesxry 16 ADA Evaluation (PAR) 2011 PROWAG R3026 1535 51,600 52,0001/1/2033-1/1/2038 205e,160 sq/ft Fm g_ 089830193>_912 IP The surface of the pedestrian access route has openings greater than 1/2 inch Pedestnan Access Rwttez openings in gratings and joints shall not permit passage of a sphere more than 13 min(D 5 in)in Shared Use Path-Finding 829720- 18 ADA Evaluation (PAR) Shared Use Path Ng Thompson Ave Surface Horizontal Openings Greater Than 1/3 Inch NA 00 3823 105.5082 diameter Open36 Open Repair the walkway eliminate openings and tripping hazard 2011 PROW.R302 9 3 DS 5 $200 WO 1/1/2020-1/1/2022 Finding_6380e98301386 3T9.mg Pedestnan Access Routes The cross slope of Me pedestrian access route is excessive replace the existing walkway Mathas anexcesxrvShared Use Path•Finding 829721Shared Use Path•Finding 829721• 19 ADA Evaluation (PAR) Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0038210 1055089 The cross slope of petlestnan access routes shall be 2 percent maximum 355%130% Open cross slope 2011 PROWAG R302 6 D35 59,200 $13,800 1/1/2033-1/1/2038 9206F to Hillside Ln Fintlmg_6300898328193_106 mg Fin g_ 0898319 _ mg Fin g_ 0098329 _ LIPS Eind1h6-5350.535n50-535 IFS The surface of the pedestrian access route has openings greater than 1/2 inch Pedestnan Access Ruutez Horizontal openings in gratings and joints shall not m permit passage of a sphere more than 13 in(05 in)in Pa.-hndi ati g829T22- 20 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Surface Horizontal Openings Greater Than 1/3Inch NA 0038251 105 50]9 diameter 12 Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R302 9 3 DS 5 $100 $300 1/1/2020-1/1/2o2T Fin g_ 0 98362 98). The detectable warning is missing at Me curb amp Pedestnan Access Routes have warning that extends Me full width of the curb ramp excluding the flared able warning surface that extends Shared Use Path•Finding 829723• 21 ADA Evaluation (PAR) Shared Sharetl Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038288 •105 507 sides 20 inch mailnmumam the d direction of travel Both sides of driveway Open Me full width of the lthetsneet crossing at the shared use path 2011 PROWAG R208 1 DS•CR MO 5800 1/1/2033-1/1/2038 Finding_6380898396070_5101pg The cross slope of the pedestrian access route is excessive Pedestnan Access Router Remove and replace the costing walkway Mat has an excessive Hillside Ln to Lakeview Storage-Shared Use Path-Fintling819T25- Shared Use Path•Rnding 829220 Use Pa.-hndng829T20- Shared Use Path•Findinge29T20- 22 ADA Evaluation (PAR)) Shared Use Path Bg Thompson Ave Slope•Cross NA NA NA 0038239 105508 The crass slope of pedestdan access routes shall be 2 percent maximum 13%085% Open cross slope 2011 PROW.R302 6 D35 $26,000 $50,0001/1/2033-1/1/2038 0501f,3,601./ft Fin g_ 98363 _ B.mg Fhndmg_6380898360021335 mg Fin g_ 983.1 3T jpg Rndmg_638089832683095 jpg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,6 is our opmmn Mat Me 2 5%cross slope falls withinShared Use Path•Finding 829725• 23 ADA Evaluation (PAR)) Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0038297 Los 5.8 The cross slope of petlestnan access routes shall be 2 percent maximum 2SO%Open conventional construction tolerance No action required 2011 PROWAG R302 6 D35 $ 5 1/1/2033-1/1/2038 Fmding_6300898013765_80 im .M1,6380898012395_163.6 The surface of the pedestrian access route has openings greater than 1/2 inch Pedestnan Access Routes Horizontal openings in gratings and joints shall not th permit passage of a sphere more an 13 min(05 in)In Path-Finding 829726- N. ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Surface Horzontal Openings Greater Than 1/3Inch NA 0038290 1055069 diameter 2 Open Repair Me walkway to eliminate openings and tripping hazard 2011 PROW.R30293 15S5 5100 $1501/1/2020-1/1/2022 Fmtling_6380e98010303_503.Ipg The sartaceofMe pedestrian access route has openings greater than 1/2 inch Pedestnan openings g g j tsMallnotpermtpa geofaspheremorethan13mm105mlin Shared Use Path•Finding 829727• 25 ADA Evaluation (PAR) Shared Sharetl Use Path Big Thompson Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 0038290 1055067 diameter 3 Open Repair..walkway to eliminate openings and tripping hazard 2011 PROWAG R30293 19S5 5100 51501/1/2020-1/1/2027 Finding_6380898020970_510.1pg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes RernOVe and replace the existing walkway that has an excessive Shared Use Path-Flnding819718- Shared Use Path•Rnding 829228 Shared Use Path-Flnding829T28- 26 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Slope•Cross NA NA NA 0038305 105.5066 The crass slope of pedesran access routes shall be 2 percent maximum 121596152% Open cross slope 2011 PROW.R302 6 D35 $1,600 52,000 1/1/2033-1/1/2038 Estes Village Inn-201F,160m/ft Finding_6380e98027990_813.mg Fhndmg_63808980287099971pg Fin g_ 98035 630.mg Pedestnan Access Routes The cross slope of the pedestrian access route is excessive e s nthat the 95%crass slopeute does have an excessive cross fallswthin o Shared Use Path•Finding 829729• 29 ADA Evaluation (PAR) Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0038337 105 5058 The cross slope of petlestnan access routes shall be 2 percent maximum 2 75%Open conventional construction tolerance No action required 2011 PROWAG R302 6 D3•5 5- 5- 1/1/2033-1/1/2038 Fintlml_63008980038T0_9191P6 Fmding_6380898a00082_6901FR The running slope of petlestnan access route exceeds the general grade of the adjacent street of Mghway. Pedestnan Access Routes Within Street arHwy Where pedestrian access routes are contained within a street or highway rightaf-way the grade of ReITIOVe and replace the existing walkway that has an excessive Shared Use Pa.-hndig819730- Shared Use Path•Finding829T30• 28 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave SMPe Running(Grade) ROW NA NA 0038356 105505 pedestrian access routes shall not exceed the general grade establlxhed for the adjacent street or highway 11 10%Open running slope 2011 PROW.R302 5 D3 5 $2,200 $10,800 1/1/2033-1/1/2038 90ue,920mMt Fmtling_638o89805093S 310.IPg Findmg_6380898055912 950 mg The detectable warning a missing at Me curb amp Pedestnan Access Routes have detectable warning that extends Me full width of the curb ramp excluding the flared able warning surface that extends 19 ADA Evaluation (PAR) Shared Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038361 105 Soy sides 20 inch mailnmumam the direction of travel Both sides of driveway Open the full width of Mel Met street crossing at the Shared use path 2011 PROWAG R2081 DSCR 5900 5800 1/1/2033-1/1/2038 Finding_6380898065192_83 jpg The detectable warning G missing at the curb amp Pedestnan Access Routes Curb ramps shall have a detectable warning that ertentls the full width of Me curb ramp excluding the flared InMall an ADA Compliant detectable warning surface that extends Shared Use Path-Finding 829732- 3D ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038362 105.5.8 sides 20 inch manum in the direction of travel Bath sides of driveway Open the full width of the the street crossing at the shared use path 2011 PROWAGR2081 DSCR MO $800 1/1/2033-1/1/2038 Fmding_6380898022551989.mg The detectable warning a missing at Me curb amp Pedestnan Access Routes have detectable warning that extends Me full width of the curb ramp excluding the flared able warning surface that extends Shared Um Path•Finding 829733• 31 ADA Evaluation (PAR) Shared Sharetl Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038295 105 Sob]sides 20 inch mailnmumam the direction of travel Both sides of driveway Open the full width of Mel Met street crossing at the shared use path 2011 PROWAG R2081 DSCR MO 58001/1/2033-1/1/2038 Finding_6380898080262_505Mg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Shared UsePa -hndng819730- Shared Use Path•Findinge29T30• 32 ADA Evaluation (PAR) Shared Use Path Bg Thompson Ave Slope•Cross NA NA NA 0038368 105.50611 The cross slope of pedestdan access routes shall be 2 percent maximum 915%Open cross slope 2011 PROW.R302 6 D3 5 $6,800 $2,200 1/1/2033-1/1/2038 60hdt,080 sq/ft Fin g_ 9808T _ 6.mg Finding_6380890088002 335 mg The detectable warning a missing at Me curb amp Pedestnan Access Routes have detectable warning that extends Me full width of the curb ramp excluding the flared able warning surface that extends 33 ADA Evaluation (PAR) Shared Sharetl Use Path Big TM1ompson Ave Curb Ramp Detectable Warnings Missing NA 0038298 105 5065 sides 20 inch mailnmumam the direction of travel Both sides of driveway Open Me full width of Mel Met street crossing at the shared use path 2011 PROWAG R2081 DSCR 5900 5800 1/1/2033-1/1/2038 Finding_63808985006._316Mg The surface of Me pedestrian access route has openings greater than 1/2 inch Pedestnan Access Routes openings in gratings and tomb shall n permit passage of a sphere more than 13 in(05 in)in Pa.-hndig 829736- 36 ADA Evaluation (PAR) shared Use Pa. Bg Thompson Ave Surface Horizontal Openings Greater Than 1/2Inch NA 0038373 105.5035 diameter l not m Damaged asphalt Open Repair the walkway to eliminate openings and tripping hazard 2011 PROM.f1.2 2 3 DS S 53,600 55,400 1/1/2020-1/1/2022 OSxe,360sq/ft Fin g_ S 98513 _ e.mg The detectable warning is missing at the curb ramp Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829]3]- 35 ADA Evaluation ;438- SharedUePathBigThCurb ampDetectablarnMissinNA :1: ::::E:;T; ; 1 . um m the travel Bah sides ofdriveway P thhtheetcrossingatthesharedth 2011 PROW. 1DSCR $7005000he pedestrute is excve EstaeoHotelEstes- Shared Ue PaM-Finding 829738- Shared Use Path•Finding 829738. Shared Ue PaM-Find98-. .legion Shared Use Path Bps Thompson Ave Slope•Cross NA NA NA . etleMan access routes Mall be 2 percent maximum ]00%Open cross slope 2011 PROWAG R3026 03S $1,600 $2,0001/1/2033-1/1/2038 20LF,160m/ft Fin g_ 9850] _004pg Finding_638089850]]302331Gg FindIng_6380e98521642_ee4.IPg Finding_63808985223I28361pg The detectable warning is missing at the curb amp tna n Access Routes Curb ramps shall have detectable warning thatextends full width of the curb ramp excluding the flared stall an compliant detectablew surface that extends Path-F 37 ADA Evaluation MAR) Shared Um Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 55016 sides 24 inch minimum in the direction of travel ext 4laatians Open Me full width of the the stree rossing at the shared use DS path 2011 PROW.R2081 CR SLAW 51,600 1/1/2033-1/1/2038 Fin g_ 0898559 _ 9dpg 10 The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shallhave a detectable warning that extends the full width of Me curb amp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829740- 38 ...legion (PAR) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA aD 3835 105502 sides 24 inch minimum in the direction of travel Both side of driveway Open the full width of the the street crossing at the shared use path 2011 PROW.R2081 DSCR $700 $8.1/1/2033-1/1/2038 Finding_63808985685304524. The detectable warning is missing at the curb amp Pedez nAcess Routes Curb ramps shall havedetectable warning thatextends full width of the curb ramp excluding the flare tall an compliant detectablew surface that extends Path-F 40 ADA Evaluation MAR) shared Shared Use Path Big Thompson Ave Curb Ramp Detectable Wammgs Missing NA 40 5006 sides 24 inch minimum in the direction of travel ext Bath sides of driveway p the full width of the the stree rossing at the shared use path 2011 PROW.R2081 DSCR $700 :::: ir- and rce the wasting walkway that M1as an excessive ShADA Evaluation IPAR) Shared Ue Path Bq Thompson Ave Slope Cross NA 4038315 105.5003 The cross slope of petlertran access routesshall be 2 percent maximum R3026 D35 $a800 2033-1/1/2038 604e,480 sy/ft FMing_63808985909365464pg Finding_6380898591]95]4e 1pg The detectable warning a missing at the curb amp n Access Routes have detectable warning that extend..full width of the curb ramp excluding the flared able warning surface that extends Shared Use Path-Finding 829740• a2 ADA Evaluation MAR)) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038302 105 4999 side 20 inch minimum inthe direction of travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR $700 5800 1/1/2033-1/1/2038 Flnding_630089859]35]_e4e1pg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedeztnan Access Rwttez However,it s our opinion that the2]5%cross slope falls within PaM-Finding 829]a5- Shared Use Path•Finding 829745. 43 ADA Evaluation MAR) Shared Use Pads Bps Thompson Ave Slope•Cross NA NA NA 4038299 105.99 The crass slope of pedestrian access routes shall be 2 percent maximum 2]5%Open cunvanionalconstruction tolerance No action required 2011 PROW.R302 6 D35 $ $- 1/1/2033-1/1/2038 Fmtling_6380e98603467591.4pg Findmg_63808986001282051pg n Access Routes The cross slope of the pedestrian access route is excessive replace the existing yexcessivethas an Shared Use Path•Finding 829706. 44 ADA Evaluation MAR) Shared e Shared Um Path Big Thompson Ave Slope•Cross NA NA NA 0038267 105 4988 The cross slope of petlestnan access routes shall be 2 percent maximum 635%Open cross slope 2011 PROWAG R3026 D3S 52,400 53,600 1/1/2033-1/1/2038 30xe,20o sq/ft Fmtlag_6300898615205_053.spg Finchng_6380898616145_3 mg The detectable warning is missing at the curb amp Pedestnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829]4]- 45 ...legion MAR)) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038268 105 4987 sides 24 inch minimum in the direction of travel Both sides of driveway Open the full width of the the street crossing at the shared use path 2011 PROWAG R2081 DSCR $700 $800 1/1/2033-1/1/2038 Fmding_6380e98619]]62964. The detectable warning is missing at the curb amp n Access Routes have warning that extend..full width of the curb ramp excluding the flared able warning surface that extends 46 ADA Evaluation MAR) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038269 •1054987 sides 20 inch minimum inthe directionof travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR $700 5800 1/1/2033-1/1/2038 Fintlag_6300898627093_6871pg The detectable warning is missing at the curb amp n Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared stall an ADA compliant detectable warning surface that extends PaM-Finding 829751- 48 ...legion (PAR)) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038249 105A982 sides 24 inch minimum in the direction of travel Both side of driveway Open the full width of the the street crossing at the shared use path 2011 PROW.R2081 DSCR $700 $800 1/1/2033-1/1/2038 Finding_6380898636247_2454. The detectable warning a missing at the curb amp n Access Routes have detectable warning that extend..full width of the curb ramp excluding the flared able warning surface that extends a9 ADA Evaluation MAR)) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038252 105 a92 side 2amh minimum inthe direction of travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR $700 50001/1/2033-1/1/2038 Finding_630089860a _ 8. e The surface of the petlestnan access route has vernal discontinuities greater than 1/2 inch or between 3/0 Inch and 1/2 inch that are not beveled Pedez nAcess Routes al Surfwe al surface discontinuities shall be al surface es betweenShared PaM-Findinge29]53- 50 ...legion (PAR) Shared Shared Use Path Bps Thompson Ave Surface Discontinuities NA NA 4038198 105A969 and U 5 inch shall be beveled with a slope not steeper 50 percent The bevel shall be applied across Me 3 Open Repair the walkway to eliminate the vertical tnpgng hazard 2011 PROW.R3027 2 D55 $300 $5001/1/2024-1/1/2027 Finding_63808986566935924pg The detectable warning is missing at the curb amp n Access Routes have warning that extends the full width of the curb ramp excluding the flared able warning surface that extends Shared Use Path-Finding 829758• 51 ADA Evaluation MAR)) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 403823 105 497e side 20 inch minimum inthe directionof travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR $700 50001/1/2033-1/1/2038 Finding_6300898672160332.1pg The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829755- 52 ...legion (PAR) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038184 105 4964 sides 24 inch minimum in the direction of travel Bath side of driveway Open the full width of the the street crossing at the shared use path 2011 PROW.R2081 DSCR $700 $800 1/1/2033-1/1/2038 Fmding_6380898680009397.IPg The detectable warning is missing at the curb amp n Access Routes have detectable warning that extends the full width of the curb ramp excluding the flared able warning surface that extends 53 ADA Evaluation MAR)) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038123 105 4951 side 20 inch minimum inthe direction of travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR 5700 50001/1/2033-1/1/2038 Finding_6380898700659_721. The cross slope of the pedestrian access route is excessive petlestnan Access Routes Remove and replace the wasting walkway that has an excessive 1560 parking lot to Murphy Shared UsePaM-Finding 829]5]- Shared Use Path•Finding 829757 Shared Use PaM-Finding 829]5]- Shared Use Path•Finding 829]5]- 5a ADA Evaluation (PAR) Shared Use Path Bps Thompson Ave Slope•Crow NA NA NA 4038155 105A959 The cross slope of pedestrian access routes.Mall be 2 percent maximum 5 90%Open vow lope 2011 PROWAGR3026 D35 $4,800 $7,200 1/1/2033-1/1/2038 resort•6DLF 080s6/ft Fmding_638089868689174tpg Rnding_638089868755035 jpg Fm g_ 98696 _ 6spg Finding_63808986969I97e jpg The detectable warning a missing at the curb amp n Access Routes have detectable warning that extends the full width of the curb ramp excluding the flared able warning surface that extends Shared Um Path•Finding 829758• 55 ADA Evaluation MAR)) Shared Use Path Big Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038076 105 4942 side 20 inch minimum inthe direction of travel Both sides of driveway Open the full width of the lthe tsneet crossing at the shared use path 2011 PROWAG R2081 DSCR $700 50001/1/2033-1/1/2038 Finding_638089872.5461_970. The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829]60- 5] ...legion (PAR) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038131 105A953 sides 20 inch nummum in the direction of travel Bath side of driveway Open the full width of the the street crossing at the shared tee path 2011 PROW.R2081 DSCR $700 $8001/1/2033-1/1/2038 fmding_6300898705066353.mg n Access Routes The cross slope of the pedestrian access route is excessive s However,6 is our opprson that the 2 75%cross so within Shared Use PatM1•Hntling 829761 • 50 ADA Evaluation (PAR) sive cross slope Pede) Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0038022 1054929 The cross slope of petlestnan access routes shall be 2 percent maximum 2]5%Open conventional construction tolerance No action required 2011 PROWAG R3026 113S 5- 5- 1/1/2033-1/1/2038 Fm g_ 0898751 _ 6mg Fin g_ 0890]52 _ 138 The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use PaM-Finding 829762- 59 ADA Evaluation (PAR) Shared Use Path Bps Thompson Ave Curb Ramp Detectable Warnings Missing NA 0038065 105 4926 sides 20 inch minimum in the direction of travel Both sides of driveway Open the full width of the the street crossing at the shared tee path 2011 PROW.R2081 DSCR $700 WO 1/1/2033-1/1/2038 Fmding_6380e98]59529]O4.mg n Access Routes The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excess's.However,n is our n that the 2 5%cross slope falls swithin Shared Use Path•Finding 829763 60 ADA Evaluation (PAR) s slope Pede) Shared Use Path Big Thompson Ave Slope•Cross NA NA NA 0037996 1054922 The cross slope of petlestnan access routes shall be 2 percent maximum 2S0%Open conventional construction tolerance No ashen required 2011 PROWAG R302 6 D3S 5- 5- 1/1/2033-1/1/2038 Fm g_ 0898765 _ ]ipg Einsling_.80.8.3333-33 I. The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal openings in gratings and loin m s shall not permit passage of a sphere more than 13 in 105 m)in Sidewalks-Finding 829768- Findmdiameterg829]08- 64 ADA Evaluation (PAR) Sidewalks Visitor Center Surface Horizontal Openings Greater Than 1/21n. NA 0037839 1055158 diameter 3]"2locations Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 135S $2AO0 $3,0001/1/2024-1/1/2027 308e,200501 FindIng_6380e98978015333spg Fndmg_638089097e780374lpg n Access Routes The cross slope of the pedestrian access route is excessive PedestnaRemove and eplae the existing walkway thathas an excessive Sidewalks•Finding 829769 Sidewalks•Finding 829769 65 ADA Evaluation (PAR)) Sidewalks Visitor Center Slope•Cross NA NA NA 0037839 •1055159 The cross slope of petlestnan access routes shall be 2 percent maximum 46%-33% open cross slope 2011 PROWAG R3026 B3S $14A00 $21,6001/1/2027-1/1/2033 180x8,1,040zq/ft Fm g_ 0898989 _ 8mg Fin g_ 089099 _ Ipg Fm g_ 0898395 _ eWE 7...-3333.33.3.-733.3 The detectable warning is missing at the curb amp Pedestrian Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared InWall an ADA compliant detectable warning surface that extends Sidewalks-Finding 829770- 66 ADA Evaluation (PAR) Shared Use Path Visitor Center Curb Ramp Detectable Warnings Missing NA 4037872 1055153 sides 24 inch minimum in the direction of travel Open the full width of the the street crossing at the shared use path 2011 PROW.R2081 BSCR $350 saw 1/1/2027-1/1/2033 Finding_6380899002756834.ing Pedestnan Access Routes The cross slope of the pedestrian access route is excessive replaceRemove and the existing walkway thathas an excessive Add turning spaceat the top of Sidewalks•Finding 830025 75 ADA Evaluation (PAR)) Sidewalks Visitor Center Slope•Cross NA NA NA 0037898 1055143 The crass slope of petlestnan access routes shall be 2 percent maximum 555%Open cross slope 2011 PROWAG R3026 133S $1,000 $1,5001/1/2027-1/1/2033 curb r p Fm g_ 090]O68 _ 31Pg Fin g_ 0003069 _ Ipg The cross slope of the pedestrian access route is excessive petlestnan Access Routes Remove and Clreplathe wasting walkway that has anexezxrve Add turning space at top of curb Sidewalks-Finding 03002]- ewalks•Hnding83002] 'jZ ADA Evaluation IPAR) Sidewalks Visitor Center Slope-Cross NA N 4037909 10551a1 The cross slope of pedestrian access routes shall be 2 percent maximum ]]5%Open cross slope 2011 PROWAGR3026 B35 $1,000 $1,5001/1/2027-1/1/2033 amp Finding_6380907O84e01813.mg Finding_63809070e56268021pg The surface of the pedestrian access mate has openings greater than 1/2 in. n Access Router openings in gratings I is shall not permit passage of a sphere more than 13 min 105 in)In Sidewalks-Finding ADA Evaluation MAR)) Sidewalks Visitor Center Surface Horizontal Openings Greater Than 1/2 Inch NA 40 3777 1055163 diameter sip a Open Repair the walkway to eliminate openings and tripping hazard 2011 PROWAG R30273 355 $100 $1501/1/2024-1/1/2027 Fin g_ O]09a _ 6ins The crop slope of Me pedestrian apes,route is excessive The pedestrian access route does have an excess.cross slope Pedestnan Access Routes Howevep it is our opinion That Me 2 696 cross slope falls within Sidewalks-Finding 830029- Sidewalks•Finding 830029• 79 am Evaluation (PAR) Sidewalks Visitor Center Slope•Cross NA NA NA 40 37871 -105 5141 The cross slope of pedestdan access routes shall be 2 percent maxlmurn 2 60%Open conventional construction tolerance Re action required 2011 PROWAG R302 6 133.5 $O $0 1/1/2027-1/1/2033 Fm2i2g_6380907101171_468spg Finding_6380907101911_564,pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/0 in.a.1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface Vertical surface discontinuities shall be 0 S mch maximum Vertical surface discontinuities between 0 2S inch Grind down the vertical surface discontinuities to eliminate Me Sidewalks•Finding 830030• 80 ADA Evaluation MAR) Sidewalks Visitor Center Surface Discontinuities NA NA 00 37873 •105 S142 and 0 S inch shall be beveled with a slope not steeper than SO percent The bevel shall be applied across the 1.' °Pe" MPPing hazard 2011 PROWAG R302 7 2 135.S $75 $150 1/1/2024-1/1/2027 Find54g_6380907105771_908 mg The handrail does not extend past the ramp 1.2 Inches. Handralls must be between 34 inches and 38 mches Wove the ramp surhce must extend beyond the top and Pedestnan Access Routes bottom of the rarnp 12 inches horizontally be parallel to Me floor or ground surface and be in the same Install handrail extensions that Wend 12"at the level surhce of 2011 PROW. Sidewalks-Finding 830031- Sidewalks•.M11030031• Sidewalks-Finding 830031- 81 ADA Evaluation (PAR) Sidewalks Visitor Center ReMP(NOI Curb Ramp) Handm ..e.l.'. Length 40 37864 -105 5144 directIon as he ramp runs The],inches must be level and does not include the mdius at The top of round 6 25%at extentions Open the mrnp landing 5404 10 1 $250 $500 1/1/2024-1/1/2027 Fmdlng_6380907117985_642spg D.1,6380907118850_302. FindIng_6380907119610_839.mg The ramp run has not been prowded with edge protechon The floor or ground surface of the rarnp run or landing shall extend 12 inches minimum beyond Me inspcle 2011 PROW.R407 9 Pedestrian Access Routes face of a handrail or a curb or barrier shall be provided that prevents the passage of a 4 inch dpameter sphere 2011 PROWAG R407 9 1 Sidewalks•Finding 830032• Sidewalks•Finding 830032• 82 ADA Evaluation (PAR) Sidewalks Visitor Center Ramp Not Curb Ramp) Edge Protection NA NA 40 37857 .105 5147 where anv portion of the sphere is Whin 4 inches of Me finish floor or ground surface D'g10 Open Install edge protection to the handrail 2011 PROWAG R407 9 2 13S•S $300 $500 1/1/2024-1/1/2027 Fmding_6380907124936_4891. Einding_638090712E742-336 loO The rlse of the nmp run is too great Pedestrian Access Routes Redesign the ramp so that the inwirmirn rise WON ramp does Sidewalks-Finding 830033- Sidewalks•Finding 830033. 83 am Evaluation MAR) Sidewalks Visitor Center ..MP(D.C..6am4/ Maximum 30 Inches Rise NA NA 40 37856 -105.5148 The.e Mr any ramp run shall be 30 inches maximum Open not exceed 30. 2011 PR0WAGR447 5 133.5 $7,500 .0,000 1/1/2027-1/1/2033 Finding_6380907133901_65300g Finding_6380907135935_754,pg The surhu of the pedestrian um31 route has openings greater than 1/2 inch Pedestnan Access Routes Horizontal openings in gratings and mi.Mall not permit passage of a sphere more Man 13 rnm 10 5 ml in Sidewalks-Finding 830035• 85 ADA 5 mluation MAR) Sidewalks Visitor Center Surface Horizontal Openings Greater Than 1/2 Inch NA 40 37827 .105 5148 diameter 1. Open Repair the wallway to eliminate openings and trippm6 has.Fd 2011 PFIC,WAG R302 7 3 83-S $100 $150 1/1/2024-1/1/2027 Find09g_6380907153716_288.1.9 The ramp run has a running slope greater than 8 396. Pedestrian Access RoWes Rgerade the ramp so Mat the running slope does not exceed Sidewalks-Finding 830036- sidewalW-Finding 830036. as ADA EvaluWon (PAR) Sidewalks Visitor Center ..mn Not Curb Ramp) Rennm.sh, NA NA 40 37826 -105.5148 Rarnp runs shall have a running slope between 5 percent minimum and 8 3 percent maximum 0 1596 Open 8 396 2011 PR0WAG11407 2 8.3•S $3,500 $5,000 1/1/2027-1/1/2033 Finding_6380907158278_54). Finding_63809071.58958_628 jpg The handml does not extend past the nrnp 12 in... Handrails must be between 34 inches and 38 inches above the ramp surface must extend beyond Me top and Pedestnan Access Routes bottom of the ramp 12 inches horizontally be parallel to Me floor or ground surface and be in Me same 9 S%slope top and Install handrail extensions that extend 12"at the level surface of 2011 PROW. Sidewalks-Finding 830037• Sidewalks•.M11030037• Sidewalks-Finding 830037• Sidewalks•.M11030037• 87 ADA Evaluation MAR) Sidewalks Visitor Center Ramp Not Curb Ramp) Handrail Extensions Length 00 37823 •105 S148 direction as he ramp runs The 12 mches must be level a74 does not include the rack at the top of round bottom Open the nrnp landing R009 10 1 $250 5500 1/1/2024-1/1/2027 Fmding_6380907164326_7731. Find1^6_63800075.S...-..iP8 ."din8-°38.3.71.672-677. F..."3.°9°7'672'-'6 j. The surhce of the pedestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 Inch and 1/2 inch that are not beveled Pedestnan Access RoPes Vertical Surface Vertdalsurface Mscontinuites shall be 0 5 inch maximum Vertwl surface discontinuities between 0 25 inch GrMd down the vertical surhce ascontinuines to elinnate the Sidewalks-Finding 830038- 88 ADA EvaluMon WAR) Ddevialks Visitor Center Surface Discontinuities Na NA 40 3782 -105 5148 and 0 5 inch shall he beveled with a slope not steeper Than 50 percent The bevel shall I.applied across The 1" Open tnpping hazard 2011 PROW.R302 7 2 85.5 675 $150 1/1/2024-1/1/2027 FindIng_6380907170753_129.mg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessNe Sidewalks•Finding 830039• Sidewalks•.M11030039• 89 ADA Evaluation MAR) Sidewalks Visitor Center Slope•Cross NA NA NA 40 37807 .105 5146 The cross slope of pedestnan access routes shall be 2 percent maximum 8 45%Open cross slope 2011 PROWAG R302 6 133.S $1,500 $2,250 1/1/2027-1/1/2033 30.1/,150m/ft D04i5g_6380907180000_908 gm Fin20g_6380907180771_251 ill The ramp does not have compliant handrails Handrails are reguired on both sides of all surfaces that are sloped greater than 5 percent(1 201 Handrails Pedestnan Access RoPes rnust be between 34 inches and 38 inches above the mrnp surface must extend beyond the top and bottorn The other side is accessible, Sidewalks-Finding 830042- sidewalks-Finding 830042- Sidewalks-Finding 830042- sidewalks-Finding 830042. 62 ADA EvaluMon WAR) Ddevialks Visitor Center Ramp Not Curb Ramp) Handree missew NA 40 3783 -105 5143 of Me ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails must be 8 496 running slope Open Install ADA drrechonal pgnage to the walkway that is compliant 2011 PROW.R409 1 85.5 $150 6300 1/1/2024-1/1/2027 install signage FindIng_6380907216560_45 spg 5ndi75_6380907218061_29 jpg FindIng_6380907223648_4740pg .6046380907225415_88 jpg The cross slope of the pedestrian Pews route d excessive Pedestnan Access Routes Remove and replace Me existing walkway that has an excessive Sidewalk-Finding 803652• Sidewalk•Finding 803652- PI ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 3809 •105 5228 The cross slope of pedestrian access routes shall be 2 percent maximum 4%Open cross slope 2011 PROWAG R302 6 133.S $800 $1100 1/1/2027-1/1/2033 10,13',80sq/ft Pm2i5g_6380543974663_4531pg Find1^6_6380,....S...-7.2 iP8 The cross slope of*pedestrian puss route Is excessive Pedestnan Access RoPes Remove and replace the wasting walkway that has an excessive Sidewalk-Finding 803653• sidewalk-Finding803653- IS ADA EvaluMon MAR) Sidewalk Mac...,fix. Slope•Cross NA NA NA 40 38104 -105 5227 The cross slope Al pedestrian access routes Thall be 2 percent maximum 12 80%Open crop slope 2011 PROW.R302 6 83.5 $640 $960 1/1/2027-1/1/2033 848%64s3ift FindIng_6380543984382_939.mg Finding_6380543985354_64 jpg The cross slope of the pedestrian awss route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalk-Finding 803654. Sidewalk•Finding 803654- 96 ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 38107 .105 5228 The cross slope of pedestnan access routes shall be 2 percent maximum 4%Open cross slope 2011 PROWAG R302 6 133.S $O SO 1/1/2027-1/1/2033 Fm2i5g_6380544001034_9881. Find1^6_6380,..005...-060 i. The cross slope Al the pedestrian access route Is excessive Pedestnan Access RoPes Remove and replace the wasting walkway that has an excessive Sidewalk-Finding 803662• sidewalk-Finding 803662- 104 am Evaluation (PAR/ Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 38527 -105 524 The cross slope of pedestdan access routes shall be 2 percent maximum 4 80%Open crop slope 2011 PROW.R302 6 83.5 6480 $720 1/1/2027-1/1/2033 VW',48m/ft FindIng_6380544091088_5760pg Fin2ng_63813544062068_529 jpg The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessNe Sidewalk•Finding 803663• Sidewalk•Finding 803663- 105 ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 38536 .105 5239 The cross slope of pedestnan access routes shall be 2 percent maximum 4 25%Open cross slope 2011 PROWAG R302 6 133.S $720 $1,080 1/1/2027-1/1/2033 no,7223 ft D04ing_6380544100412_249 gag Finding_6380544101109_973 in& The naming slope of pedestrian access route exceeds the general grade of the adwcent street of highway. Pedestnan Access Routes Within Street or Hwy Where pedestrian access routes are contained wlthin a street or hIghwas right.of-way the grade of Remove and replace the wasting walkway that has an excessive Sidewalk-Finding 803670. sidewalk-Finding 803670- 112 am Evaluation (PAR) Sidewalk MacGregor Ave DoPe•Rmning{Grade) ROW NA NA 40 37785 -105 5208 pedestrian access routes shall not exceed the general grade establdhed for the addcent street or highway 9 50%Open running slope 2011 PROW.R302 5 83.5 PAO° $3,600 1/1/2027-1/1/2033 301681,240s0/N FindIng_6380541350480_90900g Finding_6380544360526_140 mg The crop slope of the pedestrian awss route is excessive Pedestnan Access Routes Remove and replace the existing walkway that hp an excessive Curb ramp located in path of Sidewalk-Finding 803672• Sidewalk•Finding 803672- led ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 37836 .105 5214 The cross slope of pedestnan access routes shall be 2 percent maximum 6 45%Open cross slope 2011 PROWAG R302 6 133.S $O SO 1/1/2027-1/1/2033 travel Pm4i5g_6380544388773_5231pg Einding_6330.4333704-730 lox The detectable wamIng d missing at the curb ramp I Pedestnan Access RoPes Curb ramps shall have a detectable warning that Wends the full width of the curb ramp excluding the flared InPall an ADA compliant detectable warning surface th.extends Sidewalk-Finding 803673• 115 ADA EvaluWon IPAR) Sidewalk MacGregor Ave Curb Ramp Mectable Warnings Missing NA 40 37856 -105 5212 sides 24 inch nfinimurn m the direction of Wvel Mdsmg Open the full malt of the curb ramp 2011 PROW.R.208 1 8.5•CR $350 $400 1/1/2027-1/1/2033 F2tdIng_6380544396495_301.00g The crop slope of Me pedestrian awss route is excessive The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that Me 2 25.16 cross slope falls within Sidewalk-Finding 803674• Sidewalk•Finding 803674- 116 ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 37878 .105 5214 The cross slope of pedestrian access routes shall be 2 percent maximum 2 25%Open conventional construction tolerance No action required 2011 PROWAG R302 6 133.S SO SO 1/1/2027-1/1/2033 Fin4i5g_6380544406650_802 mg Finding_638054,1407528_327 Mg The cross slope of the pedestrian puss route Is excessive The pedestnan access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that the 2 95%cross slope hIls within Sidewalk-Finding 803680. Sidewalk-Eddins 803680- 122 ADA EvaluWon WAR) Sidewalk MacGregor.. Slope•Cross NA NA NA 40 37843 -105 5213 The cross slope Al pedestrian access routes shall be 2 percent maximum 2 9596 Open conventional constructIon tolerance Re action required 2011 PROW.R302 6 83.5 $0 $0 1/1/2027-1/1/2033 FindIng_63805.486433_369.00g Findm656380544487180_721 mg The surface of the pedesThan access route has ve.cal discontinuities greater than 1/2 inch or between 1/4 in.a.1/2 inch that are not beveled Pedestnan Access Routes Vertwl Surface VertIcal surface discontinuities shall!.0 5 mch maximum Vertwl surface discontinuities between 0 25 inch Grind down Me vertical pm,.discontinuities to eliminate the Sidewalk-Finding 803681• 123 ADA Evaluation MAR) Sidewalk MacGregor Ave Surface Discontinuities NA Al 40 37872 .105 5215 and 0 5 inch shall be beveled with a slope not steeper than 50 percent The bevel shall.applied across the 4. .... MPPing hazard 2011 PROWAS R302 7 2 13S•S $7S $1S0 1/1/2024-1/1/2027 Fin440g_6380544493985_543fog The surface of the pedestrian access route has openings greater than 5/2 Inch Pedestnan Access Routes Horizontal openings in gratIngs and soints shall not permit passage of a sphere more than 13 mm(0 5 in)in Sidewalk-Finding 803682• 124 am 242i424.04 IPAR) Sidewalk MacGregor Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 40 378. -105 5214 diameter 10" Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R302 7 3 85.5 $100 $150 1/1/2024-1/1/2027 FindIng_63805.499233_264.mg The crop slope of Me pedestrian apess route is excessive The pedestrian access route does have an excess.cross slope Pedestnan Access Routes However,it is our ownwn that Me 3,cross slope falls within Sidewalk-Finding 803683• Sidewalk•Finding 803683- 125 ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross NA NA NA 40 3787 •10S S213 The cross slope of pedestnan access routes shall.2 percent maximum 3 On Open conventional construction tolerance No acbon required 2011 PROWAG R302 6 133.S SO $0 1/1/2027-1/1/2033 20,8/ Fin44ng_6380544500608_14500g Fin25g_6380.544510255_671 ins The surhce of the pedestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 Inch and 1/2 inch that are not beveled Pedestnan Access Routes Vertwl Surface Vertdalsurface dwortmuites shall be 0 5 inch maximum Vertwl surface discontinuities between 0 25 inch erMd down the vertical surhce ascontinuMes to eliminate Me Sidewalk-Finding 803684. 126 ADA Evaluation WAR) Sidewalk MacGregor.. Surface Discontinuities NA NA 40 37835 -105 5214 NW 0 5 inch shall be beveled with a slope not steeper than 50 percent The bevel shall I.applied across Me 1 5" Open tnpping hazard 2011 PROW.R302 7 2 85.5 575 5850 1/1/2024-1/1/2027 FindIng_6380544514916_663.mg The crop slope of the pedestrian apes,route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalk-Finding 803685• Sidewalk•Finding 803685- 127 ADA Evaluation MAR) Sidewalk MacGregor Ave Slope•Cross Al NA NA 40 3783 •105 S213 The cross slope of pedestnan access routes shall.2 percent maximum 6 2S%Open cross slope 2011 PROWAG R302 6 83•S $3,200 $8,800 1/1/2027-1/1/2033 POW 320sq/ft Fin2i5g_6380544521857_28900g Finding_6380.544.522.528_574 jpg The running slope of pedestrian access route exceeds the general grade of the ad,acent street of highway. Pedestnan Access Routes Within Street or Hwy Where pedestrian access routes are contained within a street or hIghwas rIgMmaf-way the grade of Remove and replace the wasting walkway Mat has an excessive Sidewalk-Finding 803686. sidewalk-FMding 803686- 128 ADA EvaluMon IPAR) Sidewalk MacGregor Ave SM.-Running{Grade) ROW NA NA 40 37835 -105.5211 pedestrian access routes shall not exceed the general grade establdhed for the aMacent street or highway 8%Open running slope 2011 PROW.R302 5 83.5 $800 $1,200 1/1/2027-1/1/2033 101681,80sp/ft FindIng_6380544529111_233.00g .606563805.529950_551 mg The surface of Me pedestrian access route has openings greater than 1/2 in. Pedestnan Access RoWes Horizontal openings in gratings and soints shall not permit passage of a sphere more Man 13 mm 10 5 in)in Sidewalk-Finding 803687. Sidewalk•Finding 803687- 129 am Evaluation (PAR) Sidewalk MacGregor Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 40 3782 .105 5213 diameter Open Repair the walkway to eliminate openings and Mew.hes.rd 2011 PFOWPG.05 7 3 6S, 5100 $150 1/1/2024-1/1/2027 Fmding_6380544539500_336.1. Find1^6_63.0,..,....-..iP. The cross slope of the pedestrian awss route is excessive II. The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that Me 2 25N cross slope hlis within Sidewalks-Finding 803691- sidewalks-Finding 803691. 133 am Evaluation (PAR) Sidewalks Park In Slope•Cross NA NA NA 40 37819 -105.5213 The cmss slope of petlestdan access routes shall be 2 percent maximum 2 25N Open conventional constructIon tolerance Re action required. 2011 PROWAG R302 6 83.5 $0 $0 1/1/2027-1/1/2033 Finding_6380544568408_725mg Findms_6380544569278_236,m The running slope of the curb ramp is excessive The curb mina does have an excessive running slopHowever, Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curbnmp shall be 5 percent minimum and 83 percent maximum b.shall not is our at the running slope 305%hllswth Sidewalks-Frnding003692- Frndrng803692. 134 ADA Evaluation (PAP) Sidewalks Park Ln Curb Ramp Slope-...mg(Grade) Ramp NA 4037810 10552 50ft 855 p conventional construction tolerance No arnon required S 5 UU202]-1/1/2033 Fin g_ 05445]6 _ 2mg Frndmg_6380.445]]322C63 jag 13 require slope l of Me turning space at the tap of the curb ramp exceeds 294 maximum 2011_CR The curb ramp turning space does have an excessive running The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall slope However,t is our opinion that the 235%running slope Pedesman Access Rotes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp falls within conventional construction tolerance No action Sidewalks-Finding 803693- sidewalks-Finding 803693- 135 ADA Evaluation (PAP) Sidewalks ParkN Curb Ramp Turtling Space Slope-Punning Perpendicular Ramp 4037812 1055214 shall be Si percent minimum and 83 pervert maximum but Mall not require the ramp length to exceed 15ft 235%Open required 2011 PROW.030422 04CR $- $- 1/1/2027-1/1/2033 Frnding_6300544504073348.IPg Fndrng_63805N5852012439pg slopeThe running slope of Me turning space at the top of the curb ramp exceeds 2rt maximum The running of the curb ramp Mall cut through or shall be built up to the curb at right angles or shall Pedez nAccess Routes gutter grad t right a The running slope of the curb rampgrade the turning space of the curb ramp,so that the running Sidewalks- 0430433695- Frndrng 137 ADA Evaluation (PAP) Sidewalks Sidewalks Virginia Dr Curb Pamp Turning Space Slope-Running Perantlrcular Pamp 055214 shall be Si percent mnmum and 83 percent mammumcbutshall of require the ramplength to exceed 15ft 660 p slope does not exceed 2% AG P30422 04CR $1,000 51,5001/1/202]-1/1/2033 Fin g_ 0544604 5jag Frndmg_6380544605]]0980]jpg 1 The detectable warning is missing at the curb ramp en -POW tlln 630 342 Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of Me curb ramp excluding the flared Inrtall an ADA compliant detectable warning surface that extendsil Sidewalks-Finding 803696- 138 ADA Evaluation (PAP) Sidewalks Virginia Dr Curb Ramp Detectable Wamings Missing NA 4D.3T19 1055214 sides 24 inch minimum m the direction of travel Missing Open the full width of the curb ramp 2011 PROW.02081 95CR $350 $4001/1/2027-1/1/2033 Fmding_6300544609264_361.)pg The cross slope of the petlertnan access route is excessive Pedeztnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding 803697- Frndrng803697. Sidewalks-Finding 803697- Frndrng80369]. 139 ADA Evaluation (PAP) Sidewalks Virginia Dr Slope•Cross NA NA NA 4037697 105 5218 The cross pedestrianslope of routes shall be 2 percent maximum 4SO p cross 30 ss slope BSch 86,000 $10,2001/1/202]-1/1/2033 600zq/ft Fin g_ 0544615 _4)pg Findmg_6380,14615894711Pg Fin g_ 544621 _ e)pg Frndm 54 g_63804622094519 jag The running slope of the turning space at the top of the curb ramp exceeds 2%maximum ■ InuitThe running slope of the curb ramp shall cut through or shall be up to the curb at right angles or shall Peden nAccess Rotes The running slope of the curb ramp Pegnde the turning space of Me curb ramp,so that the running Sidewalks-Finding 830261- walks-Finding 830261- 140 ADA Evalurtron (PAR)ma Sidewalks Virginia Dr Curb Ramp Tumrng Space Slope-Punning Perpendicular Ramp 403]] 105522 shall be Si percentgrade and 83t percent maximum butnot requirethe ramplength to exceed 15ft 985%Open slope does not exceed 2% 2011 PROWAG 030422 011A $1,000 $1,500 1/1/2027-1/1/2033 Frnding_6300914868311431.IPg Fndrng_63809148691]8542)pg n Access Routes The cross slope of the petlertnan access route is excessive replaceRemove and the existing walkway thathas an excessive Sidewalks•Fending 830262 141 ADA Evaluation (PAR)) Sidewalks Virginia Or Slope•Cross NA NA NA 0037706 10S S22 The cross slope of pedestrian access routes shall be 2 percent maximum 445%Open cross slope 2011 PR0WAG R3026 03S 54,000 56,000 1/1/2027-1/1/2033 40x109400s9/ft Frntlmg_63009148720 _54.)pg Frntlmg_6380914872 _ Mg The running slope of the curb ramp is excessive Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curbnmp shall be 5 percent minimum and 8.3 percent mamma.but Mall not Reconstruct curb ramp to provide a running slope grade less Man 2011 PR0WAG 030422 Sidewalks-Finding 830263- sidewalks-Finding 830263- 142 ADA Evaluation (PAP) Sidewalks Virginia Dr Curb Ramp Slap.-Punnrng(Grade) Ramp NA 403]]06 1055219 require Me ramp length to exceed 15.0ft 1465%Open or equalto 8 394 2011 PROWAG R30432 02CR $3,000 $3,500 1/1/2027-1/1/2033 Frnding_6300914880176212.IPg Fndrng_638091488105010 jag The surface ofMM1epedertron access route has openings greater than 1/2 inch na n Access Routes Sidewalks.Fending 830264• 143 ADA Evaluation (PAR) Sidewalks Virginia Or Surface Horizontal Openings Greater Than 1/2Inch NA 003n0] 1055221 diameteroput openings gratings ) is shall not permtw passage of a sphere more than 13 ham 105 in)in ] Open Repair the walkway to eliminate openings a tripping hazard 2011 PR0WAG R3027 3 e5S $100 $1501W2024-1/1/2027 Frna.g_6380914883404_5551pg The cross slope of the pedestrian access route is excessive The pedertan access route does have an excessrve cross slope tna n Access Routes However,it is r opinion that the 27%cross slope falls within Sidewalks-Frnding030267- Frndrng83026]- 146 ADA Evaluation (PAP) Sidewalks Virginia Dr Slope•Cross NA NA NA 403]]53 105522 The cross slope of pedestrian access routes shall be 2 percent madmum 270.Open conventional construction tolerance No action required 2011 PROWAG R302 6 935 SO So 1/1/2027-1/1/2033 Frnding_6300914900257463.IPg Frndmg_6380914901048]83)pg n Access Routes The cross slope of Me petlertnan access route is excessivePede replaceRemove and the existing y Mat has an excessive Sidewalks•Frntlrng 830268 147 ADA Evaluanon (PAP) Sidewalks Virginia Or Slope•Cross NA NA NA 0037735 1055221 The cross slope of pedestnan access routes shall be 2 percent maximum 11%Open cross slope 2011 PR0WAG R3026 03S $1,O00 51,500 1/1/2027-1/1/2033 20x5,1004q/ft Frntl.g_6300314908995_199.)pg F.tmg_6380914909855_67 Mg The cross slope of the pedestrian access route is excessive The Pedeztnan access route does have an excessrv.cross slope n Access Routes MM1 z our that e2]%cross slope falls within Sidewalks-Finding 803690- Frndrnge03698- US ADA Evaluation (PAP)) Sidewalks WElkhom Ave Slope•Cross NA NA NA 40 3842 1055474 The cross slope of pedestrian access routes shall be 2 percent madmum 270%Open conventional construction tolerance No action required 2011 PROWAG R302 6 A35 SD So 1/1/2027-1/1/2033 Fin g_ 551011 _ 9aps Frndmg_638055101322]801)pg The cross slope of Me petlertnan access routers excessive The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that the 2 85%crass slope falls within Sidewalks•Fending 803699 149 ADA Evaluation (PAP)) Sidewalks WElkhorn Ave Slope•Cross NA NA NA 0038013 1055074 The cross slope of petlertnan access routes Mall be 2 percent maximum 285%Open conventional construction tolerance No action required 2011 PROWAG R3026 A35 $0 50 1/1/2027-1/1/2033 Fin g_ 0551019186_655 mg Findmg_6380SS1019837_373)pg The cross slope of the pedestrian access route is excessive The pedenran access route does have an excess.cross slope Pedeztnan Access Routes However,it z r opinion that the 26%cross slope falls within Sid.walks-Frndrng803700- Finding 803]DO- ISO ADA Evaluation (PAP) Sidewalks WElkhom Ave Slope•Cross NA NA NA 4038397 105.5483 The cross slope of pedestrian access routes shall be 2 percent madmum 260%Open conventional construction tolerance No action required 2011 PROWAG R302 6 A35 SO SO 1/1/2027-1/1/2033 Frnding_6300551026747436.)ps Frndmg_638055102]448]58 Ng n Access Routes The cross slope of the pedestrian access route is excessive h pedestrians route does have an excessive cross slope Pedestnaver,it is our slope falls withinSidewalks•Finding 8037O1 151 ADA Evaluation (PAR)) Sidewalks WEIkhorn Ave Slope•Cross NA NA NA 0038009 •1055078 The cross slope of petlertnan access routes shall be 2 percent maximum 225%Open conventional construction tolerance No action required 2011 PROWAG R3026 A35 $0 50 1/1/2027-1/1/2033 Pm g_ 0551033441686)pg Fincang_6380351034124_553)pg The cross slope of the pedestrian access route is excessive The Pedeztnan access route does have an excessive cross slope Pedeztnan Access Routes However,it z our opinion that the 215%cross slope falls within Sidewalks-Finding 803704- Frndrnge03]04- 154 ADA Evaluation (PAP) Sidewalks WElkhom Ave Slope•Cross Na NA NA 4038386 1055486 The cross slope of pedestrian access routes shall be 2 percent madmum %215Open conventional construction tolerance No action required. 2011 PROWAG R302 6 A35 SO SO 1/1/2027-1/1/2033 Frnding_6300551065561661.)ps Fndmg_6380551066161388)pg n Access Routes The cross slope of the petlertnan access route is excessivePede replaceRemove and the existing y that has an excessive Sidewalks•Fending 803709 Sidewalks-Frntlrng 803709 159 ADA Evaluation (PAR)) Sidewalks WElkhorn Ave Slope•Cross NA NA NA 0038235 1055531 The cross slope of pedestnan access routes shall be 2 percent maximum 385%Open cross slope 2011 PR0WAS R3026 A35 $14,400 $21,6001/1/1027-1/1/2033 40sq/ft Fin g_ 00$1121 _ 2.)pg Fntlmg_6380551122362o361 jag Fin g_ 0551132 _94)pg Findirg_6330SS/133135_42E Mg APprox 4,900LP 9,e004ft The shared use path is not wide enough (Cost mcludes adding an Since the shared use is dezrgned for two way travel,is additionalft of concrete to the PedeztnanAccess Routes w access The continuous clear width of petlertnan routes Mall be 100ft minimum exclusive of the width of the recommended thatthes red use paths at least lDR rag wrde concrete shared use PaM-F ding803]24- Shared Use Frndrng803724. 160 ADA Evaluation (PAR) Shared Uce Path Fall River Rd Continuous Width 120 minimum Na NA 4038296 1055418 curb 96 Open Increase the width of the shared use path 2011 PROWAG R302 3 D35 $98,000 $147,000 1/1/2033-1/1/2038 path Fm g_ 551I9] _ 3.)ps Frndrng_6380551799843152 mg n Access Routes The cross slope of the pedestrian access route is excessive h pedestrians ssive cross slope Pedestnaver,it is our opmpon that the 2 6%cross slope falls within tared Use Path•Finding e03725 • 161 ADA Evaluation (PAR)) Shared Use Path WElkhorn Ave Slope•Cross NA NA NA 0038266 1055008 The cross slope ofpedestnan access routes shall be 2 percent maximum 260%Open conventional construction tolerance No action required 2011PROWAS R302 6 A35 $0 $01/1/2027-1/1/2033 Fm g_ 0551803 _ Odpg Frntlmg_6330551e04 _ )pg The detectable warning is missing at the curb ramp Pedeztnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Inrtall an ADA compliant detectable warning surface that extends Shared Use Pa518388ng 803729- Shared Use 336451Rndrng803]29- 165 ADA Evaluation (PAP) Shared Uce Path WElkhom Ave Curb Ramp Detectable Warnings Missing NA 4038158 105.5396 sides 24 inch minimum in the direction of travel Guth side Open Me full width of the the street crossing at the shared use path 2011 PROWAG 02081 ASCR $700 $8001/1/2027-1/1/2033 fmdtag_630o551838046_664.)ps Frndrng_6380551841]]6534 As Re running slope of the curb nmp Ps excessive Pedestnan Access Routes Perpendicular or Diagonal The running slopeof the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not Reconstruct curb ramp to provide a running slope grade less than 20Shared Use Path•Finding 803730. 166 ADA Evaluation (PAR)) Shared Use Path WElkhorn Ave Curb Ramp Slap.Runmg(Grade) Pamp NA 4038155 1055395 require the ramp length to exceed 150 ft 1050%Open or equal to 83% 2011 PR0WAG R30432 A2CP $3,000 $3,500 1/1/2027-1/1/2033 Fin g_ 0551844 _ 2dpg Eindir4_6330,51.5,5).-332)pg The detectable warning is missing at the curb ramp Pedeztnan Access Rortes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Inrtall an ADA compliant detectable warning surface that extends Shared Use PaM 3g 803733- 169 ADA Evaluation (PAP) Shared Uce Path WElkhom Ave Curb Ramp Detectable Warnings Missing NA 4037887 105535 sides 24 inch minimum m the direction of travel Open the full width of the the street crossing at the shared use path 2011 PROWAG 02081 ASCR $350 $4001/1/2027-1/1/2033 Fmding_630o5518817881]3551)pg The cross slope of Me turning space exceeds the street or highway gmde. The cross slope of curb ramps hall be 2 percent maximum At n Access Routes t streettm rt rdblock petlenan rtreet«o g the cross space of the curb ramp,so that the cross Shared Use Path•Finding 803734. 170 ADA Evaluation (PAP)) Shared Use Path WElkhorn Ave Curb Ramp Turning pace Slap.Cross controls or Mrtlblock 40378]] 1055364 slope shall be permitted to equal the street or highway gnde 350%Open slope does not exceed 2% 2011 PROWAG R30453 A4CP $1,000 51,500 1/1/2027-1/1/2033 Fin g_ 0551886 _ 3dpg Eindir4_6330351.7243-071)pg The detectable warning is missing at the curb ramp Pedeztnan Access Rortes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends shared Use Pa0ng 803736- Shared Use Path•Rndmg 803736. 172 ADA Evaluation (PAP) shared U.e Path WElkhom Ave Curb Ramp Detectable Warnings Missing NA 4037886 1055352 sides 24 inch minimum in the direction of travel Guth sides Open the full width of the the street crossing at the shared use path 2011 PROWAG 02081 ASCR $700 $8001/1/2027-1/1/2033 Frnding_630o551890518962]03]9.)ps Frndmg_6380551899484103 mg The surface of the petlertnan access routers not firm stable and slip resistant Pedestnan Access Routes Min Stable And Slip The surfaces of pedestrian access routes and elements and spaces along the petlertnan access route that are 174 ADA Evaluation (PAP)) Shared Use Path WElkhorn Ave Surface Resistant NA NA 40378]] 105535 required to be accessible that connect to pedestrian access routes Mall be firm stable and slip resistant Grass to bus shuttle Open Provide an accessible rote to the bus shuttle 2011 PROWAG R3027 A55 $500 $750 1/1/2024-1/1/2027 Fin g_ 0551910 _94 Mg The detectable warning is missing at the curb ramp Pedeztnan Access Rortes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends shared Use PaM 905553g 803739- Shared Use 334451Rndrng803]39- 1]5 ADA Evalumon (PAP) Shared Uce Path WElkhom Ave Curb Ramp Detectable Warnings Missing NA 4037869 1055347 sides 24 inch minimum in the direction of travel Guth sides Open the full width of the the street crossing at the shared use path 2011 PROWAG P2081 ASCR $700 5800 1/1/2027-1/1/2033 Frnding_630o551915553115.)ps Frndrng_638055191]830]16)pg n Access Routes The cross slope of the petlertnan access route is excessivePedestna replaceRemove and the existing walkwayexcessivethas an Shared Use Path•Finding 803741• 177 ADA Evaluation (PAR)) Shared Use Path WElkhom Ave Slope•Cross NA NA NA 4037854 1055341 The cross slope ofpedestnan access routes shall be 2 percent maximum ass%Open cross slope 2011 PROWAG R3026 A35 $0 AO 1/1/2027-1/1/2033 Fm g_ 0551926103161)08_ fin g_ _ )pg The surface of the pedestrian access route has openings greater than 1/2 in. tlin638055192]0198D1 Pedeztnan Access Rortes HomoMa enings in gratings andpints all not permit passage of a sphere more than l3 m(o 5 in)ur multiple damaged Shared Use Path-Frntling e03743- Shared Use Path Hndrngeo3]AS 58 84 Path-Flntlingeo3]43- 179 ADA Evalumon (PAP) Shared Use Path WElkhomA Surface Horizontal Openings Greater Than 1/2Inch NA 4037837 1055332 dra.rter lop M ha areas on Midge Open Repair the walkway M eliminate openings and tripping hazard 2011 PROWAG P3027 3 A55 $250 5300 1/1/2024-1/1/2027 Fmtling_6300551941456164.)ps Frndrng_6380551942154909 mg Fmtling_6300551942I77_886.)pg The running slope of pedestrian access route exceeds the general grade of the ad)acent street of highway n Access Routes Within Street or Hwy pedestrian access routes are contained within a street or highway rightaf-way the grade of per than and replace the existing walkway that has an excessive Path-Finding 803]44- Shared Use Path•Finding 803744 Path 9N439Ageo3]44- Shared Use Path•Finding e03]44• 180 ADA Evaluation (PAR) shared SM1aretl Uce PaM WElkhom Ave Slope•...Ina{Grade) ROW Na NA 40 3783 10553 pedestrian access routes shall not exceed the general grade established for the ad)acent street or highway grade site. Open running slope 2011 PROWAG R302 5 A35 $5,000 $75001/1/2027-1/1/2033 SOx10,500sq/ft Fm g_ 551950 _80 ins Frndrng_638055195163123o jag Fm g_ 551954 41 jag Pndrng_63805519549]435)pg The detectable warning 0 missing at the curb ramp Pedestrian Access Routes Curb ramps shall have detectable worming thatends the full width of the curb ramp excluding the flared tall an compliant detectablew surface that extends Shared Path-Finding803745- Shared Use Finding 803]40• 181 ADA Evaluation (PAR) Shared Use Path WElkhom Ave Curb Ramp Detectable Warnings Missing NA 4037804 1055325 sides 20 inch minimum in the direction of trave one side Open the full width of the the street crossing at the shared use path 2011 PR0W.R2081 ASCR $350 $4001/1/2027-1/1/3033 Fmding_6300551957472671.IPg Findmg_6380551960000837 Ipg The cross slope of the pedestrian access route is excessive The pedestrian n Access Routes s it s opinion the 25%cross slope falls Shared Use Path•Finding 803746• 182 ADA Evaluation (PAR)) Shared Um Path WElkham Ave Slope•Cross NA NA NA 0037717 1055314 The cross slope of pedestrian access routes shall be 2 percent maximum 250%Open conventional construction tolerance No action required 2011 PR0WAG R3026 A35 50 SO 1/1/2027-1/1/2033 Fin g_ 0552860 _04Ipg Fin g_ 0552861 _Ipg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes cross slope falls within Path-Finding 803740- Shared Use Path•Finding 803748• 180 ADA Evaluation (PAR) Shared Use Path WElkhorn Ave Slope-Cross NA NA NA 003]]26 1055315 The crass slope of pedestrian access routes shall be 2 percent maximum 3%Open conventional constructiontoleranceN No required 2011 PR0WAGR3026 A35 SO SO 1/1/2027-1/1/2033 Fin g_ 05528]3 _ e.ips Finding_6380552871830118 Ipg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Vertical Surface Vertical surface discontinuities shall be 05 inch maximum Vertical surface discontinuities between 025 inch vertical surface discontinuities to eliminate the Shared Use Path•Finding 803749• 185 ADA Evaluation (PAR) Pedestrian Access Routes)) Shared Use Path WElkhorn Ave Surface Discontinuities NA NA 403]]32 1055313 The s 5 inch hall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 75 Open pp g hazard 2011 PR0WAG R3027 2 A55 $75 8150 1/1/2024-1/1/2027 Fin g_ 05528]] _ 60pg surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/6 Inch and 1/2 inch that are not beveled Pedestrian Routes al Surface surface discontinuitiesshall be al surface discontinuities between rind down the vertical surface discontinuities to eliminate the Path-F 186 ADA Evaluation (PAR) Shared SM1aretl Use Path WElkhorn Ave Surface Discontinuities Na NA 003]RS 105.532 an 05 inch shall be bevele with a slope not steeper 50 percent The bevel shall be applied across the 1 Open Aping hazard 2011 PR0W.R3027 2 A55 575 $1501/1/2020-1/1/2027 Fm g_ 552803 _ 60pg 1 The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled n Access Routes surface nuities shall be 05 inch maximum Vertical surface discontinuities between 025 inch Grind down the surface discontinuities to eliminate the Path•Finding 803751• 187 ADA Evaluation (PAR)) Shared Use Path WElkhorn Ave Surface DixoMmuites NA NA 403]]21 1055309 and 05 inch shall11 18 be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 3 Open pp g hazard 2011 PR0WAG R3027 2 A55 $75 5150 1/1/2024-1/1/2027 Finding_6380552887572_479lpg The grade of the pedestrian access route is too step. Pedestrian Access Routes Not Within Street or Hwy Where pedestrian access routes are not contained within a street or highway right-of•way the grade of Remove and replace the wasting walkway that has an excessive Shared Use Path-Finding 803752- Shared Use Path-Finding e03]52- 188 ADA Evaluation (PAR) Shared Use Path WElkhom Ave Slope•Running{Grade) ROW NA NA 403]]33 105.1 p 8 surface of routes shall be 5 percent maximum 830%Open running slope 2011 PR0W.R302 5 A35 $2,400 $3,6001/1/2027-1/1/3033 3068,MOWN Finding_638o5528909W930.IPg 6inding_6380552891931522 mg surface aftM1e pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 Th inch and 1/2 inch that are not beveled Pedestrian Access Router Vertical Surface Vertical surface shall shall be 05 inch maximum Vertical surface discontinuities between 025 inch Grind down the vertical surface discontinuities to eliminate the Shared Use Path-Finding 803753• 109 ADA Evaluation (PAR) Shared Use Path WElkhorn Ave Surface Dixonnmm�es NA NA 403]]38 10553hall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 15 Open pp a hazard 2011 PR0WAG R3027 2 A55 $75 5150 1/1/2024-1/1/2027 Fin g_ 0552890 _ 20pg OB The 0urface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/0 Inch and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface Vertical surface disannnuines shall be 05 inch maximum Vertical surface discontinuities between 025 inch Grind down the vertical surface discontinuities to eliminate the shared Use Path-Finding 803]54- DO .A Evaluation (PAR) Shared Use Path WElkhom Ave Surface Discontinuities NA NA 403]]18 10,5308 and 05 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 1 Open topping hazard 2011 PR0W.R302 7 2 A55 575 $1001/1/2034-1/1/2027 Find1ng_6300552901399_960.Ipg The grade of the pedestrian access route is too step Pedestnan Access Routes Not Within street or Hwy pedestrian access routes are not contained within a street or highway right-of•way the grade of Remove and replace the existing walkway that has an excessive Shared Use Path•Finding 803750 Path-Finding 803755- Shared Use Path•Finding 803750. 191 ADA Evaluation (PAR)) Shared Use Path WElkhorn Ave Slope•Running(Grade) ROW NA NA 403]]2 10S 5306 pedestrian access routes shall be 5 percent maximum ]60%Open running slope 2011 PR0WAG R302 5 A35 $4,000 $6,0001/1/2027-1/1/3033 00 x10,400sq/ft Fin g_ 055290] _ 3mg 6mdmg_6380552900060971 jpg Fin g_ 0552908 _ 8mg 6inding_6380552911280460114 The surface of the pedestrian access route has openings greater than 1/2 in. Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Shared U Path-Finding 803756- 192 ADA Evaluation (PAR) Shared Use PathdiameterWElkhom Ave Surface Horizontal Openings Greater Than 1/3Inch Na 403]]24 10S 5303 diameter ]OO Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0W.R302 7 3 A55 $100 $1001/1/3034-1/1/3037 Find1ng_6380552920555599.Ipg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 in.or between 1/4 inch antl 1/2 inch that are not beveled Pedestnan Access Routes Vertml Surface VeMcal surface discontinuities shall be O S inch maximum Vertml surface discontinuities between 025 inch Grind down the vertical surface discontinuities to eliminate the Shared Use Path-Finding 803757• 193 ADA Ewluanon (PAR) Shared Use Path WElkhorn Ave Surface Discontinuities NA NA 403]]3 1055304 and 05 inch shall be beveled aim a slope not steeper than 50 percent The bevel shall be applied across the 1 open ppg hazard 2011 PR0WAG R3027 2 A55 575 51501/1/2024-1/1/2027 Finding_6380SS293SS7S_915pg The gross slope of the pedestrian access route Is excessive Pedeztnan Access Roirtez Remove and replace the existing walkway that has an excessive shared Use Path-Finding 803758- Shared Use Path-Finding 803]58- DO .A Evaluation (PAR) shared Use Pam WElkhom Ave Slope•from NA NA NA 403]]31 105.5301 The crass slope of pedestrian access routes shall be 2 percent maximum 305%Open crass slope 2011 PR0W.R302 6 A35 $2,000 S3,0001/1/2027-1/1/2033 20x10,200sq/ft Find1ng_6300552938452116.0eg Findmg_6380552939354372Jpg The surface of Me pedestrian acre..route has pe gs greater than 1/2 inch Pedestrian Access Router Path Shared Use Path•Finding 803759• 195 ADA Evaluation (PAR) Shared Use Path WElkhorn Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 403]]3 3055301 lord 'al openings in gratings and Joints shall not permit passage of a sphere more than l3 mm(05 in)In 59 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PR0WAG R3027 3 A55 $100 5150 1/1/2024-1/1/2027 Fin g_ 055294 _ Olpg Finding_638055294432084 Ipg The cross slope of the pedestrian access route Is nice.. Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalk Downtown•Finding 803760-sidewalk Downtown-Finding 803700-Sidewalk Downtown•Finding 803I60- 199 .A Evaluation (PAR) Sidewalk Downtown W Ave Slope•from NA NA NA 4037608 10S S361 The crass slope of pedestrian access routes shall be 2 percent maximum 456Open grass slope 2011 PR0W.R302 6 A35 SO SD 1/1/2027-1/1/2033 Finmg_6380559605308_27S5pg Findirg_638055962366417 Ipg FindIng_6300559624511387.Ipg The detectable warning is missing at the curb amp Pedestrian Access Routes Curb ramps shall have a detectable wanting that extends Me full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalk Downtown•Finding 803I61- ZOO ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Curb Ramp Detectable Wammgs Missing NA 4037619 •1055259 sides 20 inch minimum m the direction of travel Open me full width of the curb ramp 2011 PR0WAG R2081 ASCR 8350 $400 1/1/2027-1/1/2033 Finding_6380559633985_133.04 The running slope of the turning space at the tap of the curb ramp exceeds 2%maximum - The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regnde the turning space of the curb ramp,so that the running Sidewalk Downtown•Finding 803]62-sidewalk Downtown-Finding 803762- 301 .A Evaluation (PAR) Sidewalk Downtown WElkhom Ave Curb Ramp Turning Space Slope-Running Perpendicular Ramp 4037633 10S S26 shall be S perm.minimum and 83 perm.maximum but mall not require the ramp length to exceed 15ft 330%Open slope does not exceed 2% 2011 PR0W.R30022 AO-CR $1,000 S1,5001/1/2027-1/1/2033 FiMing_6380559638794_8305pg Findmg_6380559640364807 Ipg The cross slope of the pedestrian access route is excessive Pedestnan Access Router Remove and replace the existing walkway that has an excessive Sidewalk Downtown•Finding 803763-Sidewalk Downtown-Finding 803763• 202 ADA Evaluation (PAR)) Sidewalk Downtown WElkhorn Ave Slope•Cross NA NA NA 0037617 1055261 The cross slope of pedestrian access routes shall be 2 percent maximum 390%Open cross slope 2011 PR0WAG R302 6 A35 $4,200 56,300 1/1/2027-1/1/2033 30x12,420sq/ft Fin g_ 0559656 _ 3mg 6inding_638055965I255203 jpg The gross slope of the pedestrian amen route Is excessive Pedeztnan Access Routes acre and replacethe wasting walkwaythx has an excessive Sidewalk Downtown•Finding 803IE4-Sidewalk Downtown-Finding 803]64- IS .A Evaluation (PAR) Sidewalk Downtown WElkhom Ave Slope•from NA NA NA 4037632 10S S3S9 The crass slope of pedestrian access routes Mall be 2 percent maximum111111 390%Open crass slope 2011 PR0W.R302 6 A35 $1000 $20001/1/2027-1/1/2033 14 0,140sq/ft Finding_6380559673677_7OJPg Findmg_6380559673845240 Ipg The surface of Me pedestrian access route has pe gs greater than 1/2 inch Pedestrian Router openings ing g Joints shall not permit passage of a sphere more than l3 mm(05 in)In Sidewalk Dow Finding 80376S. 200 ADA Evaluation (PAR) Sidewalk Sidewalk Downtown WElkhorn Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 4037614 1055209 diameter ap Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0Was R30273 A55 $100 $150 1/1/2024-1/1/2027 Finding_638055908,07S_3335pg The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 ham(D s in)in Sidewalk Downtown•Finding 803I66- 300 .A Evaluation (PAR) Sidewalk Downtown WElkhom Ave Surface Horizontal Openings Greater Than 1/3Inch NA 0037629 1055208 diameter ] Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0W.R3027 3 A55 $100 $1001/1/3034-1/1/3037 Finding_63005596908078660pg The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excesslve Sidewalk Downtown•Finding 80376]-Sidewalk Downtown-Finding 803]6]• 306 ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Slope•Cross NA NA NA 0037616 1055257 The cross slope of cedestnan access routes shall be 2 percent maximum 380%Open cross slope 2011 PR0WAG R3026 A35 $700 $1,0501/1/2027-1/1/3033 10x],0sq/ft Fin g_ 055969] _ ]IPg F 6,4_63305.690393130 log The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the wasting walkway that has an excessive Sidewalk Downtown•Finding 803768-Sidewalk Downtown-Finding 803768-Sidewalk Downtown•Finding 803768-sidewalk Downtown-Fining 803]68- 20] .A Evaluation (PAR) Sidewalk Downtown WElkhom Ave Slope.Gross NA NA NA 403762 10S S3S0 The crass slope of pedestrian access routesshall be 2 percent maximum 385%Open crass slope 2011 PR0W.R302 6 A35 $3,500 $5,2.1/1/2027-1/1/2033 35 x10,350sq/ft Finding_63005597172197910pg 6inding_6380559718342930 mg FindIng_6300559719602_20 mg Rndmg_6380559721036959 Ipg The cross slope of me pedestrian access route II excessive tnz n Access RoMez Remove and replace the existing walkway that has an excessive Sidewalk Downtown•Finding 803769-Sidewalk Downtown-Finding 803769•Sidewalk Downtown•Finding 803769-Sidewalk Downtown-Finding 803769• US ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Slope•Cross NA NA NA 4037627 1055254 The cross slope of pedestrian access routes shall be 2 percent maximum 410%Open cross slope 2011 PR0WAG R3026 A35 52,400 $3,6001/1/2027-1/1/3033 24 x10,240 sq/ft Fin g_ 0559I09 _ Smg 6inding_6380559]50080]S4 Mg Fin g_ 0559I5 _ 8neg Finding_6380559754032132 jpg The cross slope of the pedestrian access route II excessive Pedestrian Access Routes Remove and replace the casting walkway that has an excessive Sidewalk Downtown•Finding 803]]0-Sidewalk Downtown-Finding 803]]0-Sidewalk Downtown•Finding 803]]0-sidewalk Downtown-Fining 803]]0- 209 .A Evaluation (PAR) Sidewalk Downtown W Ave Slope•from NA NA NA 4037637 1055208 The crass slope of pedestrian access routes shall be 2 percent maximum 305%Open crass slope 2011 PR0W.R302 6 A35 $1,000 $1,500 1/1/3037-1/1/3033 10 0,]00sq/ft Find1ng_63005598]63]54010pg Findmg_63805598]]385863 Ipg Finding_6300559882954_9080pg Findmg_6380559880028823 Ipg The running slope of Me curb ramp is excemve Pedestrian Access Routes Perpendicular or Diagonal The running slope ofthe curb ramp mall be 5 percent minimum and 83 percent maximum but shall not p provide a running slope grade less than 20 Sidewalk Downtown•Finding 803]]3-Sidewalk Downtown-Finding 803]]3• 310 ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Curb Ramp Slope Runnmg(Grade) Ramp NA 4037611 10552 50ft 1445%Open or equal rto c3%a 2011 PR0WAG R30432 A2CR $3,000 $3,500 1/1/2027-1/1/2033 Fin g_ 0559888 _e4 mg Finding_63805598901I9]06 log 02 require slope ofthe turning space at the tap of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall The curb ramp turning space does have an excessive running Pedestrian Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp slope However,it is our opinion that the 3%running slope falls Sidewalk Downtown•Finding 803I72-Sidewalk Downtown-Finding 803]]2- Ill ADA Evaluation (PAR) Sidewalk Downtown WElkhom Ave Curb Ramp Turning Space Slope-Running Perpendicular Ramp 4037632 10S S3S3 shall be Si perm.minimum and 83 perm.maximum but mall not require the ramp length to exceed 1Sft 3%Open within conventional censtroction tolerance No action required 3011 PR0W.R30022 AO-CR $ 5- W/2027-1/1/2033 Finding_63005598944333250pg 6inding_6380559895890139 mg The running slope of Me curb ramp IS excessive Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not Reconstructcurb ramp to provide a running slope grade less than 20 Sidewalk Downtown•Finding 803]]3-Sidewalk Downtown-Finding 803]]3• 312 ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Curb Ramp Slope 35 u Running(Grade) Ramp NA 4037623 1055 length 50ft 1290%Open or equal 83% F 2011 PR0WAG R30432 A2CR 53,000 $3,5001/1/202]-1/1/3033 g_ 0559913 _ Jpg Finding_6380559910220300 log The running slope of the turning space at the tap of the curb ramp exceeds 2%maximum ■ The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedeztnan Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regnde the turning space of the curb ramp,so that the running Sidewalk Downtown•Finding 803]]6-sidewalk Downtown-Finding 803]]6- 30s am Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Curb Ramp Turning Space Slope-Running Perpendicular Ramp 4037619 10S 5343 shall be Si perm.minimum and 83 perm.maximum but mall not require the ramp length to exceed 1Sft 3OS%Open slope does not exceed 256 3011 PR0W.R30432 AO-CR $1,000 $1,5001/1/2027-1/1/3033 Finding_6300559900e]]5320pg Findmg_6380559982091658 Ipg The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of Me curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes meet the gutter grade break at right angles where the curb 0 curved The running slope of the curb ramp Regrade the turning space of the curb Rmp,so that the runnlng 216 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP Turning Space Slope-Running Perpendicular Ramp 40 37619 .105 5242 shall be 5 percent minimum and 8 3 percent maximum but shall not require the ramp length to exceed 15ft 3 45%Open slope does not exceed 29.6 2011 PROWAG R304 2 2 A4-CR $1,000 $1,500 1/1/2027-1/1/2033 The Rnnmg slope of the cwla ramp is excessive Pedestnan Access Routes Perpenduular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 03 percent mammurn but shall not Reconstruct curb ramp to provide a runnIng slope grade less Man 2011 PROW.R304 2 2 Sidewalk Downtown•Finding 803779-Sidewalk Downtown-Finding 8,03779- 218 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp 3,e-Runmng(Grade) Ramp NA 40 37619 -105 5241 require the ramp length to exceed 15,0 ft 10 30%Open or equal to 8 3% 2011 PROMS R304 3 2 A.2-CR $3,000 $3,500 1/1/2027-1/1/2033 FindIng_6380560005624_2470pg Findmg_6380560006508_716)p4 The running slope of Me curb rarnp is excessive Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8 3 percent maximum but shall not Reconstruct Curb ramp to provide a running slope grade less Man 2011 PROW.R304 2 2 Sidewalk Downtown•Finding 803780-Sidewalk Downtown-Finding 803780. 219 Am.-al.-Lion (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP SloPe-Runnmg(Grade) RI MP NA 40 37659 -105 5219 require Me ramp leng.to exceed 15 0 ft 12 60%Open or equal to 8 3% 2011 PROMS R3043 2 A2-CR $3,000 $3,500 1/1/2027-1/1/2033 pinding_6380560078591_748)pg Finding_6380560079488_212)08 11111. The rtmn,slope of Me turning space at the top of the curb ramp exceeds 2%ma.nuin The running slope of the curb ramp Mall cut through or shall be built up to Me curb at right angles or shall Pedestrian Access Routes rneet Me gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regrade the turning space of Me curb ramp,so that Me running Sidewalk Downtown•Finding 803781-Sidewalk Downtown-Finding 8,03781- 220 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Tomo.Space Slope-Running Perpendicular Ramp 40 37661 -105 5219 shall be 5 perce.minimum and 8 3 perce.maximum but shall not require the ramp length to exceed 15ft 4 70%Open slope does not exceed 296 2011 PROWAG R304 2 2 AO-CR $1,000 %,500 1/1/2027-1/1/2033 FindIng_6380560085410_53 jpg Findmg_6380560086576_6741pg The surface of Me pedestrian access route has openings greater than 1/2 in. Pedestrian Access Routes Horizontal openings in gratings and Joints shall not per,passage of a sphere more Man 13 rnm(0 5 m)In Sidewalk Downtown•Finding 803782-Sidewalk Downtown-Finding 803782• 221 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 40 37658 -105 522 diameter 9.'recessed bri. Open Repair the walkway to eliminate openings and tripping hazard 301.1 PROW.R303 7 3 A3-3 8500 8750 1/1/2024-1/1/2027 Fmding_6380560093463_1701pg 3lnding_6330330003373-33)38 . I I The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the wasting walkway that has an excessive Sidewalk Downtown•Finding 803783-Sidewalk Downtown-Finding 803783•Sidewalk Downtown•Finding 803783-Sidewalk Downtown-Finding 8,03783 222 am ErMuation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 40 37659 -105 5219 The cross slope of pedestrian access routes shall be 2 percent maximum 4 10%Open cross slope 2011 PROWAG R302 6 A3, $1,600 $2,400 1/1/2027-1/1/2033 8,20),160501 FindIng_638056010408234). Finding_6380560105489_957)pg FindIng_6380560107003_9520pg Findmg_6380560107689_729)pg The running slope of Me curb nmp is excessive The curb rarnp does have an excessive running slope However,it Pedessnan Access Routes Perpendicular or Diagonal The running slope of the Curb Rum shall be 5 percent minimum and 8 3 percent maximum but shall not is our opinion Mat Me running slope of 9 25%falls within 2011 PROWAG R304 2 2 Sidewalk Downtown•Finding 804554•Sidewalk Downtown-Finding 804554• 223 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP Slope-Runnmg(Grade) R0mP NA 40 37664 •105 5221 require the ramp length to exceed 15 0 ft 9 25%Open conventional construction tolerance No action required 2011 PROWAG R304 3 2 Al-CR 1/1/2027-1/1/2033 Fmding_6380560123383_197 flag 3mdm3-3330350333433-373)P8 RR ronning slope of Me turning space at the top of the curb ramp exceeds 2%maximum The running slope of the cuM ramp Mall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes meet Me gutter grade break at right angles where the curb is curved The running slope of the curb rarnp Regrade Me turning space of the curb ramp,so that Me runnIng Sidewalk Downtown•Finding 804555-Sidewalk Downtown-Finding 8,0455S- 224 am Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Tomo.Space Slope-Running Perpendicular Ramp 40 37661 -105 522 shall be 5 perce.minimum and 8 3 perce.maximum but shall not require the ramp length to exceed 15ft 3 90%Open slope does not exceed 296 2011 PROW.R304 2 2 AO-CR $1,000 $1,500 1/1/2027-1/1/2033 FindIng_6380560129662_836.wg Fin71ng_6380560130716_915.144 The detectable warning is inissing at Me curb nmp Pedessnan Access Routes Curb ramps Mall have a detectable warning that extends Me full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface Mat extends Sidewalk Downtown•Finding 804556. 225 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP Detectable Warnings Missing NA 40 37661 -105 522 sides 20 inch minimum m the direction of travel Open Me full width of Me curb ramp 2011 PROWAG R208 1 AS-CR 8350 5400 1/1/2027-1/1/2033 Fin4i6g_6380560133807_1911pg R.detectable wamIng 0 missing at the curb ramp Pedessnan Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surhce that extends Sidewalk Downtown•Finding 804599- 226 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Medal.Waminm Missing NA 40 37753 -105 5198 odes 24 etch nonimurn m Me direction of travel Both sig. Open Me full malt of de curb ramp 2011 PROWAG R208 1 A5-CR $700 $800 1/1/2027-1/1/2033 FindIng_6380560846421_6760pg The cross slope of Me pedestrian access route is excessive Pedestnan Access Routes Remove and replace Me existing walkway Mat has an excessNe Sidewalk Downtown•Finding 804600•Sidewalk Downtown-Finding 804600.Sidewalk Downtown•Finding 804600•Sidewalk Downtown-Finding 804600. 227 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 40 3776 .105 5199 The cross slope of pedestrian access routes shall be 2 percent maximum 3 3,3. Open cross slope 2011 PROWAG R302 6 A3-5 $10,000 $15,000 1/1/2027-1/1/2033 100,10,1,000sq/ft Sm4i6g_6380560864001_6599pg Fin271g_6380560864696_501 jog 3m4i6g_6380530833334_438IPg 3761773-3330330333333-333 148 The Rnning slope of Me cwla ramp is excessive Pedessnan Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8,3 percent maximum but.all not Reconstruct Curb ramp to provide a running slope grade less Man 2011 PROW.R304 2 2 Sidewalk Downtown•Finding 804601-Sidewalk Downtown-Finding 804601- 228 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp %Wm-Running(Grade) Ramp NA 40 37773 -105 5196 require the mrnp length to exceed 15.011 9 80%Open or equal to 8 396 2011 PROW.R304 3 2 A.2-CR $36900 $3,500 1/1/2027-1/1/2033 FindIng_6380560880079_8260pg Findmg_6380560881074_271 jpg The slope of Me right Oare is greater than 10% Pedessnan Access Routes Where a pedestrian circulation path crosses the curb ramp flared sides shall be sloped 10 percent maximum Replace flared side with eMer a return curb or a slope less Man Sidewalk Downtown•Finding 804602.Sidewalk Downtown-Finding 804602• 229 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb Ramp Flared Sdes Right Slope NA 40 37773 -105 5196 measured parallel to Me curb line 12 85%Open or equal to 10% 2011 PROWAG R304 2 3 Al-CR $500 5750 1/1/2027-1/1/2033 p7n4i6g_6380560886268_830)pg Fin277g_6380560887940_356 in The surface of the pedestnan access route has vertical discontimaties greater than 1/2 inch or between 1/4 In.and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface Vertical surface Mscontmuites shall be 0 S inch maximum Vertical surface discontinuities between 0 25 inch GrMd down the veMcal.1-Roe discontinuities to eliminate Me Sidewalk Downtown•Finding 804604- 231 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Surface Discontinuities NA NA 40 377. -105 5196 and 0 5 inch Mall 19e beveled well a slope not steeper than 50 percent The bevel shall.applied across Me 1 5" Open Moping hazard 2011 PROW.R302 7 2 A5, $78 $150 1/1/2024-1/1/2027 FindIng_6380560900842_8250pg The running slope of Me turning space at the top of the curb ramp exceeds 296 maxim). The running slope of the curb Rum shall cut through or shall be built up to Me curb at right angles or shall Pedessnan Access Routes meet Me gutter grade break at right angles where Me curb is curved The running slope of the curb ramp Regrade Me turning space of the curb ramp,so that the running Sidewalk Downtown•Finding 804605•Sidewalk Downtown-Finding 804605• 232 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP Turning Space Slope-Running Perpendicular Ramp 40 37763 .105 5198 shall be 5 percent minimum and 8 3 percent maximum but Mall not require the ramp length to exceed 15ft 7%Open slope does not exceed 2% 2011 PROWAG R304 2 2 Al-CR 81,000 $1,500 1/1/2027-1/1/2033 8,ar pin4i6g_6380560910296_845)pg Finding_6380560911253_699)P8 The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes meet Me gutter grade break at right angles where Me curb 0 curved The running slope of the curb ramp Regrade the turning space of the curb Rmp,so that the runnIng Sidewalk Downtown•Finding 804606-Sidewalk Downtown-Finding 804606- 233 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Tomo.Space Slope-Running Perpendicular Ramp 40 37757 -105 5198 shall be 5 percent minimum and 8 3 perce71 maximum but shall not require the ramp length to exceed 15ft 6 35%Open slope does not exceed 296 2011 PROW.R304 2 2 AO-CR $1,000 $1,500 1/1/2027-1/1/2033 FindIng_6380560917121_34). F0dmg_63805609.18069_6771p8 The detectable warning is inissing at Me curb nmp Pedessnan Access Routes Curb ramps Mall have a detectable warning that extends Me full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface Mat extends Sidewalk Downtown•Finding 804608• 235 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Curb RamP Detectable Warnings Missing NA 40 37759 •105 5198 sides 20 inch minimum m the direction of travel Open Me full width of Me curb ramp 2011 PROWAG R208 1 AS-CR 8350 5400 1/1/2027-1/1/2033 Fin4i6g_6380560927590_633. The detectable wamIng o missing at de curb ramp ...an Access Routes Curb ran.shall Pave a detectable gram.Mat eMencls de full weld of the curb ramp excluding Me flared Install an ADA compliant detectable warning surhce that extends Sidewalk Downtown•Finding 804609- 236 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Detectable Wamings Missing NA 40 37756 -105 5197 sides 24 inch onnimurn m the direction of travel Open the full wulth of the curb ramp 2011 PROW.0.208 1 AS-CR $350 Soo 1/1/2027-1/1/2033 Find13366380560933499_6050pg The cross slope of Me pedestrian access route is excessive Pedestnan Access Routes Remove and replace Me existing walkway Mat has an excessNe Sidewalk Downtown•Finding 804610.Sidewalk Downtown-Finding 804610.Sidewalk Downtown•Finding 804610.Sidewalk Downtown-Finding 804610. 237 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 00 37757 .105 5197 The cross slope of pedestnan access routes Mall be 2 percent maximum 3 496-4 25% Open cross slope 2011 PROWAG R302 6 A3, 81,820 82,280 1/1/2027-1/1/2033 2468),19245/ft F7716g_6380560939025_907.7pg Fin277g_6380560939868_95)pg F174i6g_6380560942260_91 jpg Fin117g_6380560943148_800 jpg The detectable waming is missing at Me curla rarnp Pedestnan Access Routes Curb ramps shall have a detectable wammg that extends the full wid.of the curb ramp excluding the flared Install an ADA compliant detectable warning surhce that extends Sidewalk Downtown•Finding 804611- 238 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Detectable Warnings Missing NA 40 37756 -105 5196 sides 24 inch onnimurn m the direction of travel Both Sides Open the full malt of the curb ramp 2011 PROW.0.208 1 AS-CR $700 WO 1/1/2027-1/1/2033 Find13366380560948461_6720pg The cross slope of Me pedestrian access route is excessive Pedestnan Access Routes Remove and replace Me existing walkway Mat has an excessNe Sidewalk Downtown•Finding 804612.Sidewalk Downtown-Finding 804612•Sidewalk Downtown•Finding 804612.Sidewalk Downtown-Finding 804612• 239 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 00 37758 .105 5195 The cross slope of pedestnan access routes shall be 2 percent maximum 6 8,3% Open cross slope 2011 PROWAG R302 6 A3, $9,000 $13,500 1/1/2027-1/1/2033 906109 900sq/ft p)cding_03.066096723,“7,)pg pinding_6330.0958031_649 jpg Fmding_6380560962878_6701pg 3lncling-3330360063303_1230)8 The detectable wamIng 0 missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalk Downtown•Finding 804613- NO ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Detectable Warnings Missing NA 40 37762 -105 5182 sides 24 inch rmnimurn m the direction of travel Both sides Open de full width of the curls ramp 2011 PROW.0.208 1 AS-CR $700 WO 1/1/2027-1/1/2033 FindIng_6380560968737_6430pg The cross slope of Me pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedessnan Access Routes However,0 is our opinion that Me 2 6%cross slope falls within Sidewalk Downtown•Finding 804614•Sidewalk Downtown-Finding 804614• III ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 00 37756 -105 518 The cross slope of pedestnan access routes shall be 2 percent maximum 2 60%Open conventional construction tolerance No action required 2011 PROWAG R302 6 A3, SO 80 1/1/2027-1/1/2033 Smtling_6380560973592_426.1pg 3lncling_6330330373330-733)P8 The runnrng slope of Me curb rarnp is excessive The curb rarnp does have an excessive running slope However,it Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8,3 percent mammal but shall not is our opinion Mat the running slope of 8 89.6falls within 2011 PROW.R304 2 2 Sidewalk Downtown•Finding 804616-Sidewalk Downtown-Finding 804616- 243 ADA Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Shalae-Runmng(Grade) Ramp NA 40 37785 -105 5175 require the ramp length to exceed 15,0 ft 8 80%Open conventional construction tolerance Na action required 2011 PROW.R304 3 2 A.2-CR $- 3- 1/1/2027-1/1/2033 Fi7dIng_6380560988620_5360pg Finding_6380560989535_622)pg The cross slope of Me pedestrian access route is excessive Pedessnan Access Routes Remove and replace Me existing walkway Mat has an excessNe Sidewalk Downtown•Finding 804617.Sidewalk Downtown-Finding 804617• 240 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 00 37782 .105 5175 The cross slope of pedestrian access routes Mall be 2 percent maximum 3 80%Open cross slope 2011 PROWAG R302 6 A3, 5800 81,200 1/1/2027-1/1/2033 10,3),80so/ft Fm2i6g_6380560992571_919.148 37n217g_6330330503333-334138 The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of the cuM ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes rneet Me gutter grade break at right angles where the curb 0 curved The running slope of the curb ramp Regrade the turning space of the curb Rmp,so that the runnms Sidewalk Downtown•Finding 804618-Sidewalk Downtown-Finding 804618- us am Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Curb Ramp Tuming Space Slope-Running Perpendicular Ramp 40 37806 -105 5173 shall be 5 perce.minimum and 8 3 perce.maximum but shall not require the ramp length to exceed 15ft 7%Open slope does not exceed 29.6 2011 PROW.R304 2 2 A4-CR $1,000 $1,500 1/1/2027-1/1/2033 Fi6dIng_6380561002729_1490pg Finding_6380561004795_498)pg The cross slope of Me pedertnan access route is excessive Pedessnan Access Routes Remove and replace Me existing walkway Mat has an excessNe Sidewalk Downtown•Finding 804619.Sidewalk Downtown-Finding 804619•Sidewalk Downtown•Finding 804619.Sidewalk Downtown-Finding 804619• 246 ADA Evaluation (PAR) Sidewalk Downtown W Elkhorn Ave Slope•Cross NA NA NA 00 37659 •105 5219 The cross slope of pedestnan access routes shall be 2 percent maximum 4 10%Open cross slope 2011 PROWAG R302 6 A3, $1,600 82,400 1/1/2027-1/1/2033 8,0',160sq/ft Fmding_6380560104082_34 jpg Finding_6380560105089_957 jog Finding_6380560107003_952 fpg 3..6_6330360107633_729 in The cross slope of Me pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes Howevec it is our opinion that Me 2 6%cross slope falls within Sidewalk Downtown•Finding 827615-Sidewalk Downtown-Finding 82761, 247 ADA Evaluation (PAM Sidewalk Downtown W Elkhom A Slope-Crow NA NA NA 40 37666 -105 5274 The cross slope or pedestrian access routes Mall be 2 percent maximum 2 70%Open conventional constructen tolerance No action required 2011 PROWAG R302 A3, $0 $0 1/1/2027-1/1/2033 FindIng_6380890433538501.9pg Fincling_63808,0434365_188 mg The cross slope of de pedestrian access route is excessive Pedessnan Access Routes Remove and replace Me existing walkway that has an excessive Sidewalk Downtown•Finding 827616-Sidewalk DoentOwn-Pinging 827616-Sidewalk Downtown•Finding 827616-Sidewalk Downtown-Pinging 827616- 203 am Evaluation (PAR) Sidewalk Downtown W Elkhom Ave Slope•Crow NA NA NA 4137332 -105 5286 The 01162 slope of peclestnan 111216 routes shall 022 percent maxlmurn 6 35%Open cross slope 2011 PROWAG 83426 A3, $9,600 S.A.1/1/2027-1/1/2033 120'88.,960sq/ft F1721ng_6380890437798_119904 Findmg_6380890438653_64 mg Fi72i6g_6380890440693_971904 Findmg_6380890441330_146 Jpg The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalk Downtown•Finding 827617-Sidewalk Downtown-Finding 82]61]•Sidewalk Downtown•Finding 827617-Sidewalk Downtown-Finding 82]61]• 2a9 ADA Evaluation (PAR) Sidewalk Downtown WElkhom Ave Slope•Cross NA NA NA 0037642 105 SOS The cross slope of pedestrian access routes shall be 2 percent maxlmum 375%Open cross slope 2011 PROM R302 6 A35 $0,000 $6,000 1/1/2027-1/1/2033 50xe,400sq/ft Fin g_ 90050 _ 14pg Finding_638089005094e4e0lpg FindIng_6300890458432_8924pg Finding_6380890059109407Ipg The cross slope of the pedestrian access route a excessive n Access Routes replace Me existing walkway that has an excessry Sidewalk Downtown•Finding 827618.Sidewalk Downtown-Fintlmg 827610• 250 ADA Evaluation (PAR)) Sidewalk Downtown WElkhorn Ave Slope•Cross NA NA NA 0037609 •105 5278 The cross slope of pedestrian access routes shall be z percent maximum 555%75% Open cross slope 2011 PR0WAG R302 6 A35 $8,000 $12,000 UU202]-1/1/2033 100xe,800sq/ft Fxn g_ 0890a60 _ 98p6618 Fin g_ 0890065 _ Ipg Fin g_ 0890069 _OIPB Fin g_ 0890069 _ Ipg The detectable warning is missing at the curb ramp tna n Access Routes Curb ramps shall have a detectable warning thatends the full wxdsh of the curb ramp excluding the flare tall an compliant detectable warning surface that extends Sidewalk Dow Finding e3]619- 251 ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Curb Ramp Detectable Warnings Missing NA 4037651 105520 sides 20 inch minimumm the direction of travel ex Bath Wes of Spruce Dr Open the full width of the curb ramp 2011 PR0W.R2081 AS-CR $700 $800 1/1/2027-1/1/2033 Finding_6380890474351_167,pg The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes r The running slope of the curb ramp the curb ramp,so that the run Sidewalk Downtown•Finding 827620 252 ADA Evaluation PAP Sidewalk Downtown W Elkhorn Ave Curb Ram Turning ace Slope Run Perpendicular Ram 003]653 10552]2 shall be percent minimum and 83 percent maximum but shall not the ram le to 15ft 855%and 36 Open sloe does not exceed 2% 2011 PR0WAG R30022 Aa CR $1000 $15001 202]112033 Fln 0890082 Fin 0890083 Fln o890aes (PAR) p g p p g ce p p ce q p length p p p /U -// L _ IPB e_ _ Ipg L _ Iv6 The cross slope of the pedestrian access route II excessive Pedestrian Access Routes Remove and replace the exiting walkway that has an excess Sidewalk Dow Finding 82]622-Sidewalk ding 827622• 250 ADA Evaluation (PAR) Sidewalk Downtown WElkhorn Ave Slope•Cross NA NA NA 0037657 1055271 The crass slope of pedestrian access routes shall be 2 percent maxlmum 6SO%Open cross slope 2011 PR0W.R3026 A35 $0 $0 1/1/2027-1/1/2033 Fin g_ 90500 _D.ips Findmg_63808905015833001pg The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of the Curb wrnp shall us through or shall be built up to the curb at right angles or shall n Access Routes r The running slope of the curb ramp space of the curb ramp,so that the running ding 804558-Town Hall Sidewalks-Finding 800558• 257 ADA Evaluation (PAR)) Town Hall Sidewalks WElkhorn Ave Curb Ramp Turning pace Slope Running Perpendicular Ramp 003]]69 •1055209 shall be 5 percent minimum and 83 percent maximum but shall.[require the ramp length to exceed 15ft ]%Open slope does not exceed 2% 2011 PR0WAG R30022 Al-CR $1,000 $1,500 1/1/2027-1/1/2033 Fin g_ 0560306 _ 2mg Fin g_ 05603oe _ Ipg The cross slope of the pedestrian access route Is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes However,it s our opinion that the z 15%cross slope falls within Han Sidewalks-Finding 804559-Town Hall Sidewalks-Finding 800559• 258 ADA Evaluation (PAR) Town Hall Sidewalks W Ave Slope•Cross NA NA NA 003]]61 1055209 The cross slope of pedestrian access routes shall be 2 percent maximum 2]5%Open conventional construction tolerance No action required 2011 PR0W.R302 6 A35 $0 $D 1/1/2027-1/1/2033 Finding_63805603]98535]2.lpg Finding_638056032075086jpg Re grade of the pedestrian access route is too steep The pedestrianroue runningdoes have excesswe slope er, at the n585%running slope Pedeztnan Access Routes Not Within Street or Hwy ins•within a street or highway right-of•way the grade of falls within conventional construction tolerance No action Town Hall Sidewalks•Finding 000566-Town Hall Sidewalks-Finding 800566. 265 ADA Evaluation (PAR) Town Hall Sidewalks WElkhorn Ave Slope Run.618ra.) ROW NA NA 003]]45 1055207 petleztnan access routes shall be 5 percent maximum 585%Open required 2011 PR0WAG R3025 A35 $800 $1,200 1/1/2027-1/1/2033 Fin g_ 0560385 _ 1.Ip6 Finding_6380560386881957 54 The detectable warnings missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wanting that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Town Hall Sidewalks-Finding 800567- M6 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Detectable Warnings Missing NA 003]]36 105.5206 sides 20 inch minimum in the direction of Oavel Open the full width of the curb ramp 2011 PR0W.R2081 ASCR $350 $000 1/1/2027-1/1/2033 Finding_6380560390884_e57.Ipg The cross slope of the pedestrian access route is excersrve The pedestrian ss slope n Access Routes s our opinion that the 2 a%cross slope falls within Finding Sidewalks�Finding 804569-Town Hall Sidewalks-Finding 800560• 268 ADA Evaluation (PAR)) Town Hall Sidewalks WElkhorn Ave Slope•Cross NA NA NA 003]]31 1055206 The cross slope of petleztnan access routes shall be z percent maximum 200%Open conventional construction tolerance No arnon required 2011 PR0WAG R302 6 A35 50 SO 1/1/2027-1/1/2033 pinding_6360560006836_2 Ipg Finding_638056000I6I6100 jpg The surface of the pedestrian access route has openings greater than 1/2 ind1 Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Hall Sidewalks-Finding 800570- 269 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Surface Honzonal Openings Greater Than 1/2 Inch NA 003]R diameter 10,5200 dmeter 0 Open Repair the walkway to eliminate Openings and tripping hazard 2011 PR0WAG R3027 3 A55 $100 $150 1/1/2020-1/1/2027 Finding_6300560013188_590.Ipg The running slope of pedestrian access route exceeds the general grade of the adacent street of highway n Access Router Street or Hwy pedestrian access routes are contained within a street or highway rightrof-way the grade of e p provide a running slope grade less than Hall Sidewalks•Finding e0a5]1- NO ADA Evaluation (PAR)) Town Hall Sidewalks WElkhorn Ave Slope•Running lends•) ROW NA NA 003]]2 1055203 pedestrian access routes shall not exceed the general grade established for the adacent street or highway 1015%Open or equal to c3%a 2011 PR0WAG R3025 A35 53,000 53,500 1/1/2027-1/1/2033 Finding_6380560071106_568.1p6 The detectable warning is missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wanting that extends the full width of Me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Hall Sidewalks-Finding 8005]2- 2]3 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Detectable Warnings Missing NA 00 3IR3 1055202 sides 20 inch minimum m the direction of tavel Open the full width of the curb ramp 2011 PR0W.R2081 ASCR $350 $000 UU202]-1/1/2033 Fin g_638o5600]0IA030.Ipg The counter slope att gutter exceeds 5% Pedestrian Access Routes The counter slope of the gutter or street at the foot of curb ramp runs blended transitions and turning spaces Regwde the gutter/street so that the counter slope does not Town Hall Sidewalks•Finding 804573-Town Hall Sidewalks-Finding 800573• 272 ADA Ealanon (PAR) Town Hall Sidewalks WElkhorn Ave Cum Ramp Slope at Gutter or street NA NA 0037722 1055203 shall e 5 percent maximum ]25%Open exceed 5%in Me direction of the curb ramp run 2011 PR0WAG R300 5 a Al-CR $5,000 57,000 1/1/2027-1/1/2033 Fm g_ 0560080 _ Jog Finding_6380560082360802 jpg The running slope of the turning space at the top of the cum ramp exceeds 2%maximum The running slope of he curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes e r re the curb s curved The running slope of the curb ramp Regrade the turning space of Me curb ramp,so that the running Hall Sidewalks-Finding 800570-Town Hall Sidewalks-Finding8005]0. 273 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Timing Space Slope-Running Perpendicular Ramp OD 3]]2 1055202 shall be 5 percent minimum and 83spercent maximum but shall not require the ramp length to exceed 15ft 305%Open slope does not exceed 2% 2011 PR0W.R30022 AO-CR $1,000 $1,500 UU202]-1/1/2033 FindIng_630o56008801]9674pg Fxndxng_638056008320337 jpg The detectable warning is missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a deteCtable wanting that extends the full width of the curb ramp excluding the flared tall an ADA compliant detectable warning surface that extends Hall Sidewalks•finding 00057$- 274 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Detectable Warnings Missing NA 0037699 •1055205 sides 20 inch minimum in,the direction of travel Open Me full width of the curb ramp 2011 PR0WAG R2081 AS-CR $350 saw 1/U202]-1/1/z033 Finding_6380560497695_1094Pg The cross slope of the curb ramp is greater Man the grade of Me meet Pedestrian Access Routes Without Yield or Stop Perpendicular or Diagonal The crass slope of curb ramp at the pedestrian street crossings without a yield or stop control shall be Reconstrvut curb ramp to provide a cross slope grade less than or Town Hall Sidewalks-Finding 800576-Town Hall Sidewalks-Finding 800576. 275 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Slope-Cross Controls Ramp 003]]02 105.5206 pemntted to equal the street or highway grade ]3011 Open equal to 2% 2011 PR0W.R30053 A2CR $3,000 $3,500 1/1/2027-1/1/2033 Finding_6300560508263_3394pg Findmg_6380560509265291 jpg The detectable warning is missing at the curb ramp Pedestnan Access Routes Curb ramps shall have a de...61e wanting that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Town Hall Sidewalks•Finding 80057e- 277 ADA Evaluation (PAR)) Town Hall Sidewalks WElkhorn Ave Curb Ramp Detectable Warnings Missing NA 003]] 1055202 sides 20 inch minimum in the direction of travel Open Me full width of Me curb ramp 2011 PR0WAG R2081 AS-CR $350 saw 1/1/2027-1/1/2033 Fin g_ 0560528 _ 1.ipg The grade of the pedestrian access route is too steep. The pedestrian access rode does have an excersrve running slope However,R A our opinion that the 585%running slope Pedestrian Access Routes Not Within Street or Hwy Where pedestrian access routes are not contained wrthxn a street or highway right-of.way Me grade of falls within conventional construction tolerance No action Town Hall Sidewalks-Finding 800580-Town Hall Sidewalks-Finding 800580• 279 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Slope Running{Grade) ROW NA NA 003]]23 1055199 pedesaan access routes shall be 5 percent maximum 585%Open required 2011 PR0WAG R302 5 A35 $6,000 $6,000 1/1/2027-1/1/2033 Finding_63005605653976260pg Findmg_63805605663038721pg Re grade of Me pedestrian access route is too steep pedestrian roue n rung The does have Pedestrian Access Router In Street or Hwy pedestrian access routes are not contained within a street or highway right-of•way the grade of a that the6%running slope falls Town Hall Sidewalks Finding 000581-Town Hall Sidewalks-Finding 800501• 200 ADA Evaluation (PAR) Town Hall Sidewalks WElkhorn Ave Slope•Runinglerade) ROW NA NA 003]]33 10552 petleztnan access routes shall be 5 percent maximum 6%Open within conventional construction tolerance No action required 2011 PR0WAG R3025 A35 $1,200 $1,0001/1/2027-1/1/2033 Fin g_ 05605]2 _O.Ipg Findin6_63805605I3]0631]jpg The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access ROMes Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 min(05 in)in Hall Sidewalks-Finding 800582- 281 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 003]]35 10552 diameter 2 Open Repair the walkway..eliminate openings and tripping hazard 2011 PR0W.R3027 3 A55 $1,200 $1,800 1/1/2020-1/1/2027 10 2,]Osq/ft Finding_63005605]]]33]000pg The cross slope of Me pedestrian access route is excersrve The pedestrian access route does have an excersrve cross slope tnz n Access Routes s our opinion that the 2 a%cross slope falls within walks•Finding 800583-Town Hall Sidewalks-Finding 800503• 282 ADA Evaluation (PAR) Town Hall Sidewalks WElkhorn Ave Slope•Cross NA NA NA 003]]33 1055201 The crass slope of petleztnan access routes shall be z percent maximum 200%Open conventional constructiontolerance No acton required 2011 PR0WAG R302 6 A35 $0 se 1/1/2027-1/1/2033 Fintlag_63005605 _ 9.Ipg Finding_6380560585563658.i. The slope of the right flare is greater than 10% Pedestrian Access Routes Where a pedestrian circulation path crosses the curb ramp flared sides shall be sloped 10 percent maxmum Replace flared title with either a return curb or slope less than Town Hall Sidewalks-Finding 804584-Town Hall Sidewalks-Finding 800580 283 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Flared SW. Right Slope NA 003]]03 10552 measured parallel to Me curb line 15%Open or equal to UM 2011 PR0W.R30023 AO-CR $500 $750 1/1/2027-1/1/2033 Finding_630056059657991pg Findmg_6380560597506932 jpg The cross slope of the pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the existing walkway that has an excersrve Town Hall Sidewalks-Finding 800585-Town Hall Sidewalks-Finding 800585•Town Hall Sidewalks•Finding 804585-Town Hall Sidewalks-Finding 800583• 200 ADA Evaluation (PAR) Town Hall Sidewalks WElkhorn Ave Slope•Cross NA NA NA 003]]03 1055103 The crass slope of petleztnan access routes shall be z percent maximum 925%35% Open cross slope 2011 PR0WAG R302 6 A35 $0,e00 51,2001/1/2027-1/1/2033 80x6,080m/ft Fin g_ 0560600 _ 6mg Finding_6380560605285306 jig Fin g_ 0560612 _ .P8 Finding_63805606130029a9jpg The cross slope of the curb ramp s greater than 216 to provide a cross slope grade less than or Pedestrian Access Routes Perpendicular or Diagonal and 3OS% equal tot%Regrade the turning space so that the running and Hall Sidewalks-Finding 800586-Town Hall Sidewalks-Finding 800586.Town Hall Sidewalks-Finding 800586-Town Hall sidewalks-Finding 800586• 285 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Curb Ramp Slope-Cross Onote Ramp 003]]53 1055201 The crass slope of curb ramps blended tnnsltions and turning spaces shall be 2 percent maximum landing to Open cross slopes do not exceed 2% 2011 PR0W.R30053 A2CR $3500 $0,000 1/1/2027-1/1/2033 Finding_6300560627030399,pg Findmg_63805606281091711pg FindIng_63005606312374128pg Findmg_6380560632255112 fps The cross slope.(the pedestrian access route is excessive tnz n Access Routes Remove and replace the existing walkway that has an excessive Town Hall Sidewalks•Fading 804587-Town Hall Sidewalks-Finding 800587 206 ADA Evaluation (PAR) Town Hall Sidewalks WElkhorn Ave Slope 52 cross slope of pedestrian access routes shall be z percent maximum 415%Open cross slope 2011 PR0WAG R302 6 A35 $2,000 $3,0001/U202]-1/1/2033 10x20,200sq/fs Fin g_ 0560636 _O.IPg Rnding_6380560636936550 jig I Cross NA NA NA 003]]09 105 02 The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/6 inch and 1/2 inch that are not beveled Pedeztnan Access Raltez Vertical Surface Vertwi surface diswntinwbes shall be 05 inch maximum Veinal surface discontinuities between 0 25 inch Stain to police Town Hall sidewalks-Finding o0580-Town Hall Sidewalks-Finding 800586•Town Hall Sidewalks-Finding 800588-Town Hall Sidewalks-Finding 800588• 287 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Surface Discontinuities NA NA 003]]51 105 5201 and 0 5 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across Me department Open Provide an accessible rote to the Police Department entrance 2011 PR0W.R3027 2 A55 $3,500 SSA.1/1/2020-1/1/2027 Finding_6300560605622_7384pg Findmg_63805606490069911pg FindIng_63005606500906008pg Findmg_638056065099927 jog The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope m of she curb rap shall cut through or shall be built up to the curb at right angles or shall Pedestnan Access Routes rneet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regnde the turning space of the curb ramp,so that the running Town Hall Sidewalks•Finding 804583-Town Hall Sidewalks-Finding 800589• 208 ADA Evaluation (PAR) Town Hall Sidewalks W Elkhorn Ave Curb Ramp Turning Space Slope Running Perpendicular Ramp 003]]60 1055201 shall be 5 percent minimum and 83 percent maximum but shall not require the ramp length to exceed 15ft 845%Open slope does not exceed 2% 2011 PR0WAG R30422 Al-CR 51,000 $1,500 1/1/2027-1/1/2033 Fin g_ 0560656 _OIp6 Rnding_638056065n59282 jpg I The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway Mat has an excessive Town Hall Sidewalks•Finding 804590-Town Hall Sidewalks-Finding 800590 289 ADA.-aluaion (PAR) Town Hall Sidewalks WElkhorn Ave Slope•Cross NA NA NA 0037757 1055202 The crass slope of pedestrian access routes shall be 2 percent maximum 330%Open cross slope 2011 PR0W.R302 6 A35 $960 51p00 1/1/2027-1/1/2033 Is.',6zq/ft Fin g_ 560665 _ 21pg Rnding_6380560666606712 jig The grade of the pedestrian access route is too steep Pedeztnan Access Routes Not Well.Street or Hwy esnan contained wit.a street or highway right-of.waythe grade of and replace the existing walkway that has an excessive Hall Sidewalks•.M81304591-Town Hall Sidewalks-Finding 800591• 290 ADA Evaluation (PAR) Hall Sidewalks WEIkM1om Ave S Na NA 403777 10552 pedestrian access routes shall bea5 percent mammon 830 p running slope P3025 A35 5320 50801/1/202]-1/1/3033 ex air Fin g_ 05606]3 _ 2 Jog Finding_6380560673991325 jpg 05 The surface of the petlestnan access route has vertical docontinumes greater than 1/3 inch or between 1/4 AG 0', inch antl 1/3 inch that are not beveled Pedesman Acresz Rau[ezVertical Surface Vertical surface discontinuities shallbe 05 mc0 maximum Venial surface discontinuities between 035 inch Town Hall Sidewalks•Finding ea592- 391 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Surface Discontinuities NA NA PO 37773 105.5199 and 05 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be aPphed across the Step to parking fee Open ttO the amenity 3011 PROWAG R302 7 2 A55 $750 $10001/1/2034-1/1/3027 Finding_6380560688563_337epg The cross slope of the pedestrian access route is excessive The pedestrian slope Pedestrian Access Routes so within Hall Sidewalks•Finding 800593-Town Hall Sidewalks-Finding 800593• 292 ADA Evaluation (PAP) Town Hall Sidewalks WElkhorn Ave Slope•Cross NA NA NA 55206 Thecrozz slope of petlestnanaccers routes shall be2Dercent maximum 2 wnvennonailaconmuctiontole alma 3Noactionreguiretla A35 50 501/1/202]-1/1/3033 Fin g_ 0560I9] _ 7.)pg Finding_6380560]9I00]251 jpg 1U The cross slope of the pedestrian access route is exceszrve 35'Pen26 630 009 E5 Pedeztnan Access RPtitea Remove and replace the existing walkway that has an excessive Town Hall Sidewalks-Finding 804595-Town Hall Sidewalks-Finding 800595.Town Hall Sidewalks-Finding 804595-Town Hall sidewalks-Finding 800595 290 ADA Evaluation (PAR) Town Hall Sidewalks W Elkhom Ave Slope•Crow NA NA NA 003]]62 ]055205 ThecrozxzloPe at petlesmanaccess routershall bet Dercent madmum 425%0 8511 Open a..slope 3011 PROWAG R3026 A3S $3,300 $3,8001/1/3037-1/1/3033 006e.320ser/N Finaing_6380560813150726eps Findms_63805608103025221pe Finding_63805E08181E8_762.IPg Findms_63805608188650011pe The cross slope of the pedestrian access route is excessive The pedestrian excessive o e wn hin I Sidewalks•Finding 800596-Town Hall Sidewalks-Finding 800596. DA as A Evaluation (PAP)tnan Access Routes Town Hall Sidewalks WElkhorn Ave Slope ]� Cross NA NA NA 603 055303 The crass slope of petlestnan access routes shall be 2 percent maximum 270 p conventionaHowever,it l sconstruction tolea our opimon that hnce e 2]No action required 3011 PR0W.R3026 A35 $0 $01/1/2027-1/1/2033 Fin g_ 056082] _ 8$pg Finding_6380560820288909 jpg MEI 1 The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the wasting walkway that has an excessive Town Hall Sidewalks-Finding 804597-Town Hall Sidewalks-Finding 800597.Town Hall Sidewalks-Finding 804597-Town Hall Sidewalks-Finding 800597 296 ADA Evaluation (PAR) Town Hall Sidewalks WElkhom Ave Slope•Cross NA NA NA 003]]e6 1055301 The cross slope of pedestrian access routes shall be 2 percent maximum 30,6.8% Open a..slope 3011 PROWAG R302 6 A35 $2,400 53,6001/1/2027-1/1/2033 306e,300.0) Finding_6380560831090311eps Findmg_6380560832198250 jog Finaing_6380560830056500.IPg Rndmg_63805608367215361pg The running slope of pedestrian access route exceeds the general gade of the atlacent street of highway ztna n Access RoutesStreet or Hwy Where pedearign access routes are contained within trof-way the grade of 7 75%(step w than r o replace the existing walkway that has an excessiveShared Use Path•Finding 803711Shared Use Path•Finding 803711• 299 ADA Evaluation (PAR) Shared Use Path Fall River Rd slope Pun n IGraael OW NA NA 0o 380oa 10550I3 pedestrian access routes shall not exceed the general grade established for the atlacent street ay grade) Open run slope 2011 PR0WAG 83025 D35 53,000 53,6001/U2033-1/1/3038 Kra',200sq/h Findng_63005516585]26291pg Findmg_63s055165538e_s]Ipg Fin 0551662 Iv Fin 0551663 IP e g e g e_ _ B e_ _ e The shared use path is not wide enough Pedeztnan Access Rattez The continuous clear width of pedestrian access routes shall be to oh minimum exclusive of the width of the shared Use Path-Finding 803713- Shared Use Finding eo3n2- 300 ADA EvaluWon (PAR) Shared UsePath Fall River Rd Continuous Width 120r minimum NA NA 0038015 1055069 curb 96 Open Refer to Record 160 for Reccomendatlan and Pnang 3011 PROW.R302 3 D35 $ $- 1/1/2033-1/1/3038 Finding_638055166710e_883eps Findmg_6ssoSsl38055166]9]2123 jog n Access Routes The cross slope of the pedestrian access route is excessive h pedestrians route does have an excessive cross slope ztna slope falls withinShared Use Path•Finding e03733 301 ADA Evaluation (PAR) Shared D.P. Fall River Ptl Slope•Cross NA NA NA 0038019 •1055072 The cross slope of pedestrian access routes shall be 2 percent maximum 225%Open conventional construction tolerance No action required 2011 PR0WAG 83026 1)35 50 SO 1/1/2033-1/1/2038 Findng_6300551673658_97 jpg Nndmg_6380551670310_5361pg The running slope of petlestnan access route exceeds the general grade of the atlacent street of highwry. n Access Routes Wahln Street or Hwy Wherepedestriancontained within Highway rights!-way the grade of %(steeper than streetand re replace the eating walkway that has an excess Path-F ding803716- Shared Use Findmg803716 Path-Finding803716- Shared Use Findmg803]36- SOO ADA Evaluation (PAR) Shared Shared Use Path Fall River Rd Slope.Roming(Gade) ROW NA NA 0038001 1055063 pedestrian accss routes shall not exceed the general grade established for the atlacent street or highway grade) Open running slope Fl 3011 PROW.R302 5 035 $18A00 $37,6001/1/2033-1/1/3038 230'69',1,e40zq/ft Fnding_6380551692291229eps Findmg_6380551]0220015]jpg Fnaing_6380551I0289]86). Findmg_6380551]10130]051pg n Access Routes The cross slope of the pedestrian access route is excessive ztna replace the existing walkway thathas an excessrvShared Use Path•Finding 803738. 306 ADA Evaluation (PAP) Shared D.P. Fall River Ptl Slope•Cross NA NA NA 0038261 105502s The cross slope of petlestnan access routes shall be 2 percent maximum 320%Open cross slope 2011 PROWAG 83026 D35 51,600 53,400 1/1/2033-1/1/2038 20xe,llosq/h 6mdng_630055173 _aap6 Fnamg_63805517362a9_3521pg The cross slope of the pedestrian access route is excessive Pedeztnan Access Routes PPIPOVe and replace the westing walkway that has an exceszrve Shared Use Path-Finding 803719- Shared Use Path•Rndmg8o3]39- 3D] ADA Evaluation (PAP) Shared Use Path Fall River Rd Slope•Cross NA NA NA 0038318 1055024 The cross slope of pedestrian access routes shall be 2 percent madmen 3SO.Open cross slope 3011 PROW.R302 6 D35 $800 $1,3001/1/2033-1/1/3038 106e,80N/ft Fnding_6380551I01]]8503eps Findmg_6380551743035939 Ipg The running slope of pedestrian access route exceeds the general grade of the atlacent street of highway The pedestrian access route does have an excessive running slope er, running slope ztna n Access RoutesStreet or Hwy Where pedestrian access routes are contained within tiro!-way the grade of falls within conventional construction tolerance No actionShared Use Path•Finding 803721• 309 ADA Evaluation (PAP) Shared Use Path Fall River Ptl Slope Punine IGraael ROW NA NA 0038318 1055021 pedestrian access routes shall not exceed the general grade established for the atlacent street or g ay 585%Open required 2011 PR0WAG 83025 1)35 50 50 1/1/2033-1/1/3038 6mdng_6300551I59 _9a Ipg Finamg_6380551760 _ Ipg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes it a our opinion that the 225%cross slope falls within shared UUsePa.-Finding 803723- Shared Use Path-Finding 8o3R3- 310 ADA Evaluatnn (PAR) Shared UUsePath Fall River Rd Slope•Cross NA NA NA 0038316 1055031 The cross slope of pedestrian access routes shall be 2 percent maximum 225%Open conventional construction tolerance No action required 2011 PROWAG113026 035 Sim So 1/1/2033-1/1/3038 Finamg_638055176647313). N1dng_638055176729029 jpg The surface of the pedestrian access route has openings greater than 1/2 in. ztna n Access Romeo Shared Use Path.Finding 837440. 315 ADA Evaluation (PAP) Shared Use Path Fish Creek Trail Surface Horizontal Openings Greater Than l/21nch NA 4036.8 105 4934 diameter openings gratings Join.shall not perms passage of a sphere more than l3 min(05 m)In 3 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PR0WAG 83027 3 1$55 5100 5150 1/1/2020-1/1/2027 Finang_6300888159292_75.06 Finamg_6380880159951_816)P6 The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 mUsem(05 m)in shared U Path-Finding 837043- Shared Use Path•Finding 827443. 318 ADA Evaluation (PAP) Shared UUsePath Fish Creek Trail Surface Horizontal Openings Greater Than l/21nch NA 0036517 105 4903 diameter 1 Open Repair the walkway to eliminate openings and tripping hazard 3011 PROW.R302 7 3 D55 $2,400 53,600 1/1/2034-1/1/3037 306e,200ser/N Finding_63808882e012084ag Findmg_6380888200e73496 Ipg The gode of the pedestrian access route is too steep n Access Routes in Street or Hw containedwi ma street or highway right-of.way the grade of o replace the existing walkway that has an excessive Shared Use Path•Finding 837440 Shared Use Path•Finding 827440. 319 ADA Evaluation (PAP) Shared SM1aretl Use Path Fish Creek Trail Slope•Punning leraae) POW NA NA 40360]] 105 4902 pedestrian access routes shall bees percent 9, Open running slope 2011 PR0WAG 83025 1)35 $13,500 520,250 1/1/2033-1/1/2038 135x10',1,3504ft Fin g_ 0808218 _Oa 1p6 Fin g_ 088822 _ Ipg Fin g_ 0888220 _1pe Fin g_ 0888222 _ Ipg The grade of the pedestrian access route is too steep The pedestrianroute does have an excessive running slope ver, our that the 5running slop n Access Routes in Street or Hwy pedestrian contained within a street o highway right-of.waythe grade of fall conventional construction tolerance No action Path-F ding e37046- Shared Use Finding82]a46. 321 ADA EvaluWon (PAP)tna Shared Use Path Fish Creek Trail Slope•Running(Grade) ROW NA NA 0036337 105 4906 pedestrian access routes shall be 5 percent M1n 585%Open required ti 3011 PROW.R302 5 035 $0 50 1/1/2033-1/1/3038 Fnding_6380e88258919275.IPg Findmg_63808882595100311pg The grade of the pedestrian access route is too steep ztna n Access Routes Not Within Street or HMO contained withma street or g ayright-of.way the grade of Remove and replace me existing walkway that has an excessiveShared Use Path•Finding 82]40] Shared Use Path•Finding 82]40]. 322 ADA Evaluation (PAP) Shared Use Path Fish Creek Trail Slope Puning leraae) POW NA NA 4036328 105 4908 peaeztrian access routes shall be 5 percent maximum 950%Open running slope 2011 PR0WAG 83025 1)35 50,000 56,000 1/1/2033-1/1/3038 00 0,000sq/ft Fin g_ 08082 _eC a6 Fin g_ 088026] _ jpg Fin g_ 08882]3 _ SIp6 Fmclin6_6360668273752-63 Ipg The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal mUse openings in gratings and Joints shall not permit passage of a sphere more than 13 in(05 in)in shared U Path-Finding 837051- 326 ADA Evaluation (PAP) Shared UUsePath Fish Creek Trail Surface Horizontal Openings Greater Than 1/21nch NA 0036007 105 4959 dumater Damaged concrete Open Repair the walkway to eliminate openings and tripping hazard 3011 PROW.R302 7 3 D55 $6,000 %NO 1/1/3034-1/1/3027 5panels,Case/ft Finding_6380888335a1083.4epg sidewalk starts at Johnsen Ln The shared use path is not wide enough hkkdmg South ApProx 1,5000 dice the shared use path is designed for two way travel,6 iz L.0 sq/ft(Cost mcludw Pedestnan Access Routes width continuous clear width of pedestrian access routes shall be 10 oh minimum exclusive of of the s least 10ft wide adding an adalbonal lft of Shared Use Path•Finding 82I453 Eva 328 ADA luation (PAP) Useidth Shared U Path Fish Creek Trail Continuous W 120 minimum Na NA 4035886 105096 curb 9shared use pa. Open Increase the width that the shoed use path 2011 PR0WAG 83023 1)25 $15,000 $22,500 1/1/2033-1/1/2038 concrete to the ea g Fin g_ 08883]0 _ 21p6 Fin g_ 08803n _ Ipg The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal m openings in gratings and Joints shall not permit passage of a sphere more than 13 m(05 in)in Path-Finding e37055- Shared Use Path•Finding 827455. 330 ADA Evaluation (PAP) shared UUsePath Fish Creek Trail Surface Horizontal Openings Greater Than 1/21nch NA 0035665 105 4967 diameter Damaged concrete Open Repair the walkway to eliminate openings and tripping hazard 3011 PROW.R302 7 3 055 $5A00 $8,100 1/1/2034-1/1/3037 60i6,500se/N Fnding_6380e08412139153eps Findmg_638088801293801 jpg The shared use path is not wide enough ztna n Access Routes The continuous clear width of pedestrian access routes shall be 30 oh width minimum exclusive of the of theShared Use Path•Finning 82I456 331 ADA Evaluation (PAP) Shared Use Path Fish Creek Trail Continuous Width 1206 minimum NA NA 4035658 105097 curb a Open Refer to Record 328 for Peccomenaation and P g 2011 PR0WAG 83023 0.25 5 $- 1/1/2033-1/1/2038 Fin g_ 0888a25 _ ]Ipg Fin g_ 0ee803e _ IPe The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedeztnan Access Routes However,it s our opinion that the 285%crass slope falls within shared UUsePath-Finding 837057- Shared Use Path•Finding 82]45]. 332 ADA Evaluation (PAP) shared UUsePath Fish Creek Trail Slope-Cross NA Na NA 0035643 105 4973 The crass slope of pedestrian access routes shall be 2 percent madmen 285%Open conventional construction tolerance No action required. 3011 PROW.R302 6 035 $0 $D 1/1/2033-1/1/3038 Finding_6380888429523680epg Finding_63808800301398161pg There are vertical surface discontinuities greater than lk or between l/a'nch and 1/2'nch that are not beveled n Access Routes Surface e1/2m Vertical surface discontinuities between 1H'mch and weal surface discontmuMes to eliminate the Shared Use Path-Finding 333 ADA Evaluation (PAP) Shared SM1aretl Ue Path Fish Creek Trail Curb Pamp Discontinuities Na NA 4035551 1050981/2 inch shall cbe beveled wihsaaslope not steeper than 50 percent The bevel shall be applied across the 1 Open Pp g hazard 2011 PR0WAG 83027 2 D6CR $50 5100 1/1/2033-1/1/3038 Country b•North Fm g_ 0888a03 _3a0jp6 The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the wasting walkway that has an excessive shared,e Pa.-Finding e3]0]3- Shared Use Finding 82]a]3- 336 ADA EvaIuWon (PAP) Shared Ue Path Fish Creek Trail Slope-Cross NA NA NA 0035524 105098 The crass slope of pedestrian access routes shall be 2 percent madmen 950%Open cross slope 3011 PR0W.R302 6 D35 $0 $0 1/1/2033-1/1/3038 Finding_6380888466983_265epg Findmg_65506583808880680]0a85 Ipg The surface of the pedestrian access route has openings greater than 1/2 inch ztna n Access Routes Shared Use Path.Finding 82]4]5• 338 ADA Evaluation (PAP) Shared Use Path Fish Creek Trail Surface Horizontal Openings Greater Than l/21nch NA 4035501 105 4979 diameter openings gratings 1 .shall not perms passage of a sphere more than l3 dim(05 m)'in 3 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PR0WAG 83027 3 1$55 $700 51,050 1/1/2024-1/1/3037 7,0,70zq/ft Fin g_ 0888a9 _ jpg Finding_6380888095394_850.1pg The grade of the pedestrian access route is too steep. Pedeztnan Access Routes Not WrtInn Street or Hwy Where pedestrian access routes are not contained within a street or highway right-of.waythe grade of Remove and replace the wasting walkway that has an excessive Shared Use Path-Finding e2]0]6- Shared Use Path•Finding 82]4]6. 339 ADA Evaluation (PAP) Shared Ue Path Fish Creek Trail slope.Running(Grade) ROW NA NA 0035514 105 4979 petlestnan access routes shall be 5 percent maximum 695%Open running slope 3011 PROWAG113035 D35 $4,000 $6,000 1/1/2033-1/1/3038 00 0,000se/ft Fna1ng_6380888505863_236.IPg Findmg_63808805067655021pe The cross slope of.e pedestrian access route is excessive tna n Access Routes Remove and replace the existing walkway that has an excessive Shared Use Path-Finding 8270]]- Shared Use Path•Finding 837477. 340 ADA Evaluation (PAP) shared Ue Path Fish Creek Trail slope•Cross NA NA NA 0035503 105 4979 The crass slope of petlestnan access routes shall be 2 percent maximum 13%Open cross slope 3011 PROW.R3026 D35 $3,000 $05001/1/2033-1/1/3038 30 0,300se/ft Finaing_6380e885179362001Pg Findmg_6380888510040108 jpg Me cross slope of Me pedestrian access route is excessive Me pedestrron access route does have an excessive cross slope Pedestnan Access Routes However,it PS our opmon Mat Me 2 5,cross slope falls mt. Shared Use Path-Fatting 827078- Shared Use Path•Findmg 827478. 301 am Evaluation (PAR) shared Use PaM FiM Creek Trak Slope•Cross NA NA NA 40 35509 -105 4579 The cross slope of pedestrian access routes shall be 2 percent madinurn 2 50%Open conventional construction tolerance No aroon required 2011 PROWAG11302 6 DMS 80 $0 1/1/2033-1/1/2038 F8dI3g_6380888529359_218km Findmg_63805.88529959_318 mg Me cross slope of Me turning space exceeds 20 maximum Me cross slope of curb ramps blended transitions and turning spaces shall be 2 percent maximum At Pedestnan Access Routes With Weld or Stop pederonan street crossings without weld or stop cottrol and at inidblock pedestnan street crossmgs Me cross 3 50 tunrog space Regrade Me turning space of the curb ramp,so that the cross Shared Um Path•Finding 827480• Shared Use Path•Finding 827480• Shared Um Path•Fmrong 827080• 343 ADA Evaluation (PAR) Shared Um Path Fish Creek Trail Curb RamP Turning Space Slope-Cross Controls 40 352M -105 499 slope shall be penzotted to equal the street or highwaS gmde everything else compliant Open slope does not exceed 20 2011 PROWS.R304 5 3 DMCR $1,000 81,500 1/1/2033-1/1/2038 Fmding_6380888564006_1061pg F11.11,6330.6.3737-531M3 ...-......3-.4. The surface of the pedestrian access route has openings greater than 1/2 in. Pedestnan Access Routes Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 rnm(0 5 in)in Shared Use Pa.-Fmding 827481- Shared Use Path•Findmg 827481• 344 am Evaluation (PAR) Shared Use Path Fish Creek Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 40 35119 -105 5001 diameter Open Repair the walkway to eliminate openings.a tr0p.08.... 2011 PROWAS.07 7 3 ..3 $100 $150 1/1/2024-1/1/2027 Fin2ing_638088857984.3_219km Finding_6380888.580419_604 mg Mere are vertu!surface discontinuities greater Man 1/2 or between 1/4 inch and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface Wrocal surface discontinuities shall be 1/2 maximum Vertiml surface discontinuities between 1/4 inch and Grind clown Me veNical surface discontinuities to eliminate the Shared Um Path-Finding 827083• 346 ADA Evaluation (PAR) Shared Use Path Fish Creek Trail Curb RamP Mrooronuites NA NA 40 35039 •105 5007 1/2 inch Mall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the I, 03" MProng hazard 2011 PROWAG R302 7 2 D6•CR 55.0 8100 1/1/2033-1/1/2038 Findi8g_6380888598377_477.1. Mere are vertical surface romontinuMes greater than 1/2 or between 1/4 inch and 1/21nch that are not beveled. Pedestnan Access Routes Veroml Surface Vertmal surface Mscoronuites shall be 1/2 maronum Vertml surface romontinurtiro between 1/4 inch and Grind down the vertical surface droontmuibes to eliminate the Shared Use Path-Fatting 827484- 307 am Evaluation (PAR) Shared Use Path Fish Creek Trak Curb Ramp Dpscontinutes NA NA 40 35043 -105.5007 1/2 inch roall be beveled with a dope not steeper than 50 percent The bevel shall be applied across the 1 V' Open tnpping hazard 2011 PROW.R302 7 2 D6•CR $50 $100 1/1/2033-1/1/2038 F8dI3g_6380888605813_05 mg Me running slope of pedestrian access route exceeds the general grade of the attacent street of highway The pedestrian access route does have an excesswe running Pedestrian Access Routes WMin Street or Hwy Where pedestrian access routes are contained within a street or highway right.of-way Me grade of slope HOWE'Ver,II is our opinion that the 5 0%runMng slope falls Shared Use Path-Finding 827480- Shared Use Path•Finding 827488• 351 ADA Evaluation (PAR) Shared Um Path Firo Creek Trail 3...num,.lerade) ROW NA NA 00 34399 •105 5012 pedestrian access routes shall not exceed the general grade established for the attacent street or highway 5 40%Open within conventional construction tolerance No action required 2011 PROWAG R302 5 D3•S 80 80 1/1/2033-1/1/2038 Fmding_6380888600001_330mg F11.11,6330.5.10.-353M2 Starting at Scott Ave APP.. Me shared use path is not wide enough 3.,1,500sq/0(Cost includes Since the shared use path is designed for two way travelM is adding an addltional 2frof Pedestnan Access Routes Me continuous clear width of pedeMnan aroess routes shall be 10 Oft minimum exclusive of the width of the recommended that the shared use path is at least 10frowde concrete to the existMg Shared Use Path-Finding 827491- Shared Use Path-Finding 827491. Shared Use Pa.-Finding 827491- 355 ADA Evaluation (PAR) shared Use Path Lakeshore Or Trail Continuous Width 120.minimum NA NA 40 34858 -105 5029 curb Open Increase the width of the shared use path 2011 PROW.R302 3 200 $18,000 $27,000 1/1/2033-1/1/2038 °nor.shared use path) FmdIng_6380888669522_893km Finding_6380888671311_354 jpg FmdIng_6380888672571_249.4 Me surfam of Me pedestrian access route has openings greater than 1/2 inch Pedestnan Access Routes HorpoMal openings in gratings and Joints shall not permit passage of a sphere more Man 13 mm(0 Sin)in Shared Use Path•Fmrong 827092• 356 ADA Evaluation (PAR) Shared Um Path Lake Shore Dr Tr. Surface Horizontal Openings Greater Than 1/2 Inch NA 40 34868 .105 5026 diameter Open Repair the wallemay to eliminate openings and tripping hazard 2011 PROWAG R302 7 3 135.S $100 $150 1/1/2024-1/1/2027 Fin4ing_6380888682878_8921. Me running slope of pedestrian um.route exceeds the general grade of the attacent street of highway. Pedestnan Access Routes Within Street or Hwy Where pedestrian access routes are contained wlthin a street or highway right.of-way the grade of Remove and replace the wasting walkway that has an excessive shared Use Pa.-Finding 827493- Shared Use Path-Finding 827493. shared Use Pa.-Finding 827493- Shared Use Path-Finding 827493- 357 ADA Evaluation (PAR) Shared Use MIL Lakeshore Or Trail Slope•Running{Grade) ROW NA NA 40 34822 -105.5034 pedestnan attem routes shall not exceed Me general grade established for the attacent street or highway 10,5 5% Open running slope 2011 PROW.R302 5 0.30 $2,160 $3,240 1/1/2033-1/1/2038 2738',216s.qh FindIng_6380888690407_609km Finding_63808.88601030_840 jpg Fin2I3g_6380888652324_608,2 Findmg_63808.88602979_167.rog The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace Me existing walkway Mat has an excessive Shared Um Path-Finding 827094• Shared Use Path•Finding 827494. 358 ADA Evaluation (PAR) Shared Um Path Lake Shore Dr Trad Slope•Cross NA NA NA 40 34732 .105 5048 Me cross slope of pedestnan access routts Mall be 2 percent maximum 4 70%Open cross slope 2011 PROWAG R302 6 DMS 83,200 $4,800 1/1/2033-1/1/2038 POW,320m/ft Fm2i3g_6380888711771_486 1pg F1nd1^3_6330.67.573-530M3 Me required addifional maneuvering space is not provided Mr a parallel approach Where a clear space is confined on all or part of three fidro addifional maneuvering space shall be provided Pedestnan Access RoMes Confined Greater than 15 Relocate the dog waste Wpm they are accessible frorn the 2011 PROW.R404 7 shared Use PaM-Finding 827495- 359 ADA Evaluroon (PAR) Shared Use Path Lake Shore Or Trail Clear Floor Space Parallel Approach Inches Maneuvering Space 40 34737 -105 5049 Me clear space and attroonal maneuvering space shall 1m 5 Oft wide minimum where the depth exceeds 15 At dog bags Open shared use path 2011 PROW.R404 7 2 1330 $50 $100 1/1/2033-1/1/2038 Find1,6380888723366_628km Me grade of Me pedestrian access route is too steep Pedestnan Access Routes NM Within Street or Hwy Where pedestrian access routes are not contained withal a street or highway right-ohway Me grade of Remove and replace the existing walkway that has an excessive Shared Um Path-Finding 827496- Shared Use Path•Finding 827436. Shared Use Path-Fmrong 827496- Shared Use Path•Finding 827436. 360 ADA Froluaron (PAR) Shared Use Path Lake Shore Dr Trail Slope•Running(Grade) ROW NA NA 40 34848 .105 503 pedestrian access roMes shall be 5 percent maxmum 9 25,8 55% Open running slope 2011 PROWS.R302 5 DMS $5,000 $7,500 1/1/2033-1/1/2038 SOMO.500sq/ft F.nding_6380888730823_45.2 im Finding_6380880731085_656 jpg Finding_6300888734808_46 jpg .6,6380888735097_875 Mg Me surhu of the pedestrian access route has openings greater than 1/2 ill. Pedestnan Access RoMes Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 rnm(0 5 m)in shared Use PaM-Finding 82707- Shared Use Path-Finding 827497- 361 ADA Fvaluroon (PAR) shared Use Path Lakeshore Or Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 40 34679 -105 507 diameter Damaged concrete Open Repair the walkway to eliminate openings and romfing hazard 2011 PROWAGR302 7 3 0.50 $3,000 54,500 1/1/2024-1/1/2027 30,0,300sq/ft FindIng_638088875435.5_8874. Findi0g_63808887.55110_72 jpg Me grade of Me pedestrian access route is too steep The pedestrian access route does have an excesswe running Pedestnan Access Routes NM Withln Street or Hwy Where pedestrian access routes are not contained withal a street or highway right-dm,Me grade of slope However,A is our oproon that the 6%running slope falls Shared Use Path-Finding 827490- Shared Use Path•Finding 827498. 362 ADA Froluaron (PAR) Shared Um Path Lake Shore Dr Tod Slope•Running leradel ROW NA NA 40 34675 .105 507 pedestrian access roMes shall be 5 percent maxmum 60 Open within conventional construction tolerance No action required 2011 PROWS.R302 5 DMS $0 SO 1/1/2033-1/1/2038 Fmding_6380888762302_759mg F1nd11,6330.6737070-361M3 The surface of the pedestrian access route has openings greater than 1/2 irldl Pedestnan Access RCN. Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mm(0 5 in)in shared Use PaM-Finding 827499- 363 ADA Evaluroon (PAR) shared Use Path Lakeshore Or Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 40 34673 -105.5073 diameter Open Repair the walkway to eliminate opeifings aro trop1n3 hazard 2011.0WA613307 7 3 03.3 $100 $150 1/1/2024-1/1/2027 FindIng_638088877074.5_508km Me surface of Me pedestrian access route has openings greater than 1/2 inro Pedeanan Access Routes Horizontal openings in gratings a.m.Mall not permit passage of a sphere more than 13 mm(0 5 in)In Shared Use Path-Finding 827501- Shared Use Path•Finding 827501• 365 ADA Froluaron (PAR) Shared Use Path Lake Shore Dr Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 00 34665 -105 509 diameter Damaged concrete Open Repair the wallmay to eliminate openings and tripp1ng hazard 70..0..R307 7 3 ..3 $3,000 54,500 1/1/2024-1/1/2027 30,0.300sq/ft Finding_6380888813104_50 jpg Finding_6380680814059_100 Mg WI Me cross slope of the pedestrian mum route Is excess. Pedestnan Access R.I. Remove and replace the wasting walkway that has an excessive Shared Use PaM-Finding 827502- Shared Use Path-Finding 827502- 366 ADA Evaluroon (PAR) Shared Use Path Lake Shore Or Trail Slope•Cross NA NA NA 40 34663 -105 5089 Me cross slope of pedtttrlan access routroMall be 2 percent maximum 6 0596 Open cross slope 2011 PROWAGR302 6 20.5 $5,000 $7,500 1/1/2033-1/1/2038 50,0%50aq/ft Find1,6380804821043_8564. Finding_63808.88821949_618 mg The required addironal maneuvering space is not prowded for a parallel approach Where a clear space is confined on all or part of three sroro additional maneuvering space shall be provided Pedestnan Access Routes Confined Greater than 15 Relomte the dog waste bop so they are accessible Worn the 2011 PROWAG R404 7 Shared Use Path-Fmrong 827504- Shared Use Path•Finding 827504• 368 ADA Froluaron (PAR) Shared Um Path Lake Shore Dr Trail Clear Floor Smce Parallel Approach Inches Maneuvering Space 40 34679 •105 5117 Me clear space and adchronal maneuvering space shall be 5 Oft wide minimum where Me dep.exceeds 15 27. Open shared use path 2011 PROWAG R404 7 2 DMS 55.0 5100 1/1/2033-1/1/2038 Fmding_6380888843404_5901pg F110111,6330.6"3330-133-4.3 Me surface of the pedestrian access route has openings greater than 1/2 irldl Pedestnan Access 1.1.1.5 Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mm(0 5 in)in Shared Use PaM-Finding 827505- Shared Use Path-Finding 827505- shared Use Pa.-Finding 827505- 369 ADA Evaluroon (PAR) shared Use Path St Vrain Ave Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 40 34683 -105 5119 drorntter Open Repair Me walkway to eliminate openings and tripping hazard 2011 PROWAGR302 7 3 12.50 $100 $130 1/1/2024-1/1/2027 FindIng_6380888858864_504km Finding_63808.88862240_947 mg FindIng_6380888863182_289,2 Me shared use path is not wide enough Since the shared use path is designed for two way travel,is Approx 8,5001F 85,000sq/ft Pedestnan Access Routes Me continuous clear width of pedestrian access routes shall be 10 Oft minimum exclusive of Me mdth M the remmmended that the shared use path is at least 1011 wide (Cost mcludro removal and Shared Um Path•Fmrong 827506- Shared Use Path•Finding 827506• Shared Use Path-Fmrong 827506• 370 ADA Froluaron (PAR) Shared Use Path St,Main Ave Trail Continuous Width 120.minimum NA NA 40 34678 .105 5118 curb Open Incream the width of the shared use path 2011 PROWAG R302 3 D2•5 5680,000 $050,000 1/1/2033-1/1/2038 replacement of existing ashpalt)Finding_6380888866812_3681pg .M2_6380880860340_711 Mg Finding_6300888868885_280 wg I Me surhu of the pedestrian access route has openings greater than 1/2 irldl Pedestnan Access 1.1.1.5 Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mrn(0 5 in)in Multiple gaps in asphalt shared Use PaM-Finding 827507- Shared Use Path-Finding 827507- 371 ADA Evaluroon (PAR) shared Use PaM St Vrain Ave Trail Surface Horizontal Openings Greater Than 1/2 Inch NA 40 34695 -105 5118 Marntter along entro trail Open Repair the walkway to eliminate openings and ropping hazard 2011 PROWAGR302 7 3 12.50 $100 $100 1/1/2024-1/1/2027 Per lomtion FindIng_6380888872.17_285,2 Findmg_63808.88879120_867 km Me cross slope of the pedestrian access route is excesfive The pedestrian access route does have an excesswe cross slope Pedestnan Access RoMes However,rt is our mmon that Me 2 250 cross slope falls within Shared Use Path-Finding 827500- Shared Use Path•Finding 827508• 372 ADA Froluaron (PAR) Shared Um Path St,Main Ave Trail Slope•Cross NA NA NA 00 34702 .105 5118 The cross slope of pedestnan access routts shall be 2 percent maximum 2 25 Open conventional construction tolerance No aroon required 2011 PROWAG R302 6 DMS 50 Se 1/1/2033-1/1/2038 Fmding_6380888882530_876mg F1nd10086330666333033-030M3 IMe grade of the pedestrian access route is too amp. Pedestnan Access 1.1.1.5 Not Within Street or Hwy Where pedestrian access routes are not contained within a street or highway nght-ofmay Me grade of Remove and replace the wasting walkway that has an excessive shared Use PaM-Finding 827509- Shared Use Path-Finding 827503- 373 ADA Evaluroon (PAR) shared Use Path St Vrain Ave Trail Slope•Running{Grade) ROW NA NA 4D 3475 -105 5116 pedestrian access routes shall be 5 percent maronum 1011 Open running slope 2011 PROWAGR302 5 0.30 $15,000 $22,500 1/1/2033-1/1/2038 1501)10',1,500m/ft FindIng_6380888893588_790.4 Findmg_63808.88890913_764 mg The cross slope of Me pedestrian access route is excessive Pedestnan Access RoMes Remove and replace the existing walkway that has an excessive Shared Use Path-Finding 827510• Shared Use Path•Finding 827510. 370 ADA Froluaron (PAR) Shared Use Path St,Main Ave Trail Slope•Cross NA NA NA 00 34713 .105 5118 Me cross slope of pedestnan access routts shall be 2 percent maximum 10%Open cross slope 2011 PROWS.R302 6 DMS 83,200 54,800 1/1/2033-1/1/2038 4088',320m/ft Finding_6380888900926_951 mg Finding_6380680311791_862 Mg M. Me surface of the podestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 In.and 1/2 inch that are rot beveled Pedestnan Access 1.1.1.5 Vertml Surface Vertmal surfam Mscoronuites shall be 0 5 inch maronum Vertml surface discontinuities between 0 25 inch Shared Use Path-Finding 827511- Shared Use Path-Finding 827511- shared Use Pa.-Finding 827511- 375 ADA Evaluroon (PAR) shared Use Path St Vrain Ave Wad Surface Discoromulties NA NA 40 34736 -105.5117 and 0 5 inch shall be beveled wiro a slope not steeper than 50 percent The bevel shall be applied across Me 3.for 4.of asphalt Open Repair the walkway to elinntte openings and tripping hazard 2011 PROWAGR302 7 2 D50 $100 $102 1/1/2024-1/1/2027 Fin0Ing_6380888924424_646,2 Findmg_63805.88925119_673 mg FindIng_6380888928080_552,2 Me grade of Me pedestrian access route is too steep Pedestnan Access RoMes NM Withln Street or Hwy Where pedestrian access routes are not contained withal a street or highway right-dm/ay Me grade of Remove and replace the existing walkway that has an excessIve Shared Use Path-Fmrong 827512- Shared Use Path•Finding 827512• 376 ADA Evaluation (PAR) Shared Use Path St,Main Ave Trak Slope•Running(Grade) ROW NA NA 40 3494 .105 5103 pedestrian access roMes shall be 5 percent maximum 10 950.Open running slope 2011 PROWAG R302 5 DMS Szaoo 83,600 1/1/2033-1/1/2038 30,8',240m/ft Findi8g_6380888935937_809 mg .6,6380888937006_125 jpg Me detectable wamIng is missing at the curb ramp Pedestnan Access 1.1.1.5 Curb ramps shall have a detectable warning that extends the full width of Me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use Pa.-Finding 827513- 377 ADA Evaluroon (PAR) shared Use Path St Vrain Ave Trail Curb 118111p Detectable Warnings Missing NA 4D 3494 -105 5103 fides 24 inch rnInimurn m the direction of travel Both sides of Scott Ave Open the full wdth of the the streerormfing at the shared use path 2011 PROW.R208 1 D.S.CR $700 $800 1/1/2033-1/1/2038 Fin2Ing_638088894.5081_562,2 Me cross slope of Me pedestrian access route Ls excessive Proestnan Access RoMes Remove and replace the existing walkway that has an excessIve Shared Um Path-Finding 827514- Shared Use Path•Finding 827514. Shared Um Path-Fmrong 827514- Shared Use Path•Finding 827514. 378 am Evaluation (PAR) Shared Use Path St,Main Ave Trak Mope•Cross NA NA NA 40 34771 .105 5115 Me cross slope of pedestnan access routes shall be 2 percent maximum 10%.8% Open cross slope 2011 PROWAG R302 6 DMS So 1/1/2033-1/1/2038 Scott Ave I.Ammo Fmding_6380888955057_555 mg Finding_6380880556014_818 jpg Fmding_6300888956858_384 wg Findmg_6380888361441_415 Mg Me detectable warning is missing at the curb ramp Pedestnan Access 1.1.1.5 Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared InMall an ADA compliant detectable warning surface that extends shared Use PaM-Fmding 827515- 373 ADA Fvaluroon (PAR) 301722 Use PaM St Vrain Ave Trail 01rb Ramp Detectable Wanrogs Missing NA 40 35104 -105 5087 fides 24 inch minimum in the direction of travel 5210 sides of Acacia Open Me full mall of the the streerormfing at the shared use path 2011 PROW.R208 1 125.CR $700 $800 1/1/2033-1/1/2038 FindIng_6380888982.691_938,2 The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excess. Shared Use Pan-Finding 827516- Snared Use Path•Finding 827516 Use Pan-Finding 827516- Snared Use Path•Finding 827516. 300 ADA Evaluation (PAR) snared Use Pan St Pram Ave Trail Slope•Cross NA NA NA 0035081 305 SOBS Thecrazz slope of cetletnanaaers routes nail bets percent maximum %Open wssslape D35 50,000 : W : : ;I: 03 : g_6380888.an a cend Use Path-Fi4035132 105508cce 1030%0pen cro0WR30 $D Pndmg_63808890158911681og The detectable warning is missing at the curb vamp Pedestnan Routes Curb ramps shall hair detectablew mmg to extends the full width of the curb ramp excluding the flare stall an...compliant detectablew surfate that extends Pan-Finding82J510- 3B2 ADA Evaluation (PAR)tna Snared Ue Pan St Vrain Ave frail Curb Ramp Detectable Warnings Missing NA 50a9 sides 2a inch minimum in the direction of travel eat Bath sides of Avalon p the full width of the the stree rossing at the snared use pan 2011 PR0W.R2081 DSCR 5700 5800 1/1/2033-1/1/2038 Fin g_ 0889091 _ erns MI �305 The detectable warning is missing at the curb amp Pedestnan Access Routes Curb ramps shall have a detectable warning that extends the full width of Me curb amp excluding the flared Install an ADA compliant detectable warning surface that extends Snared Use Pan-Finding82J519- 383 ADA Evaluation (PAR) Snared UsePan St Vrain Ave Trail Curb Ramp Detectable Warnings Missing NA 4035522 105.5047 sides MI inch minimum m the direction Memel Bath sides of Country Club Open the full width of the the street crossing at the shared use _path 2011 PR0WAG R2081 DSCR $700 $800 1/1/2033-1/1/2038 Fin g_ 89099 _ 2.Ipg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessbre Shared Use Path-Finding827520- Shared Use Path•Finding 827520 Shared Use Pan-Finding 82J520- 304 ADA Evaluation (PAR) Snared Use Pan St Pram Ave Trail Slope•Crass NA NA NA The crass slope of pedestrian access routes shall be 2 percent maximum 435% pet cuss slope 51,600 52,400 1/1/2033-1/1/2038 N Fin g_ 088910J _ Finding_Dipg 6380889100095504jpp Fin g_ 0089112 _ 61pg 003lir-OS 504J The grade of the pedestrian access route is too step. Pedestnan Access Wanes Not Wan Street or Hwy Where pedestrian access routes are not contained wrtnin a street or highway ngnohway the grade of and replacethe wasting walkwaythat has anexreszrre Shared Use Pan-Finding 827521- Shared Use Path-Finding 827521- shared Use Pan-Finding 827521- Shared Use Path-Finding 82J521- 385 ADA Evaluation (PAR) Snared Use Pan St Vrain Ave Trail Slope-Running{Gade) ROW NA NA 00355a7 1055047 pedesnan access routes shall be 5 percent maximum 1385%565% Open running slope 2011 PR0WAG R3025 D35 $8,000 $12,000 1/1/2033-1/1/2038 100 ),BOOsq/N Findes_6380e89121024_328.). Findmg_63808891216042061ps FindIng_6380889128260850.). Findmg_63808891289978681pg Pedestnan Access Routes The cross slope of the pedestrian access route is excessive replace the existing walkway Mathas an excessShared Use Path•Finding 837522Shared Use Path•Finding 827522• 386 ADA Evaluation (PAR) Shared Use Path St Vrain Ave Trail Slope•Cross NA NA NA 4035577 105 SOAR The cross slope of oeaestnan access routes shall be 2 percent maximum 785%33% Open cross slope 2011 PR0WAG R302 6 D35 58,800 $13,1001/1/2033-1/1/2038 110xe,ee0sq/N Finang_6300ee9104450_307 in Fin g_ 08891aa _ Tog Rm g_ 0809150 _ 11Pg Fin g_ 0809151 _ log The detectable warning is missing at the curb amp Pedestnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Bath side of sixth Green Install an ADA compliant detectable warning surface that extends snared Use Pan-Finding82J523- 38] ADA Evaluation (PAR) Snared Use Pan St Vrain Ave Trail Curb Ramp Detectable Warnings Missing NA 0035741 1055039 sides MI inch minimum in the direction of travel Ln Open Mefull width of Me the street crossing at the shared use path 2011 PR0W.R2081 DSCR 5700 $800 1/1/2033-1/1/2038 Finding_6380889171741913.ipg Pedestnan Access Routes The cross slope of the pedestrian access route is excessive replace the existing walkwayexcessivethas an Shared Use Path•Finding 837524Shared Use Path•Finding 837524. 388 ADA Evaluation (PAR) Snared Use Path St Vrain Ave Trail Slope•Cross NA NA NA 4035685 105 50a2 The cross slope of oeaestnan access routes shall be 2 percent maximum 38%111% Open cross slope 2011 PR0WAG R3026 D35 50 50 1/1/2033-1/1/2038 Finang_6300889195453_7411pg Fin g_ 0889196 _ ipg Rmding_638080920761M721Pg Frn._6580.5.08,54-5FA in The detectable warning is missing at the curb amp Pedestnan Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use Pan-Finding 817525- .9 ADA Evaluation (PAR)) snared Use Pan St Vrain Ave Trail Curb Ramp Detectable Warnings Missing NA 4035823 1055039 sides 2a inch minimum in the direction of Oeel Both side of Holiday Open the full width of the the street crossing at the shared use path 2011 PR0W.R2081 DSCR $700 $800 1/1/2033-1/1/2038 Fnding_6380889212797_468.1pg The grade of the pedestrian access route is too steep Pedes tnan Access Routes Not Within Street or Hwy net within a street or g ayright-ohway the grade of Remove and replace the existing walkway that has an excessiveShared Use Path•Finding 837526Shared Use Path•Finding 837526. 390 ADA Evaluation (PAR) Snared Use Path St Vrain Ave Trail Slope•Running(Grade) ROW NA NA 4035823 1055039 pedestrian access routes shall be 5 percent maximum 119%88% Open running slope 2011 PR0WAG R3025 D35 50,000 $12,000 1/1/2033-1/1/2038 10oxe,800sq/N Fmdng_6300889221280_145 mg Fmdmg_638088922197321 rim Rm g_ oee92z]a53_3321Pg Findmg_6380889220 _ mg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes a and replace the existing walkway that has an excessive ePan-Finding 827527- Shared Use Path•Finding 02J52J ePan-Finding 827527- FShared,3208U333108FindingezJSZJ- 391 ADA Evaluation (PAR)) Snared Use Pan St Vrain Ave Trail Slope•Cross NA NA NA 4035913 1055038 The cross slope of pedestrian access routes shall be 2 percent maximum 695,3 75% Open cross slope 2011 PR0W.R3026 D35 SO SO 1/1/2033-1/1/2038 Holiday to Golf Course Rd Fin g_ 89239 _ 6z. Findmg_63808892402293361pg Fin g_ 89251 _ea.mg Findmg_63808B9z519866]61pg The detectable warning is missing at the curb ramp Pedestnan Access Routes have detectable warning that extends[.full width of the curb ramp excluding the flared Bo ides of Golf Course able warning surface Mat extends Shared Use Path-Finding 827528• 392 ADA Evaluation (PAR) Shared Snaretl Use Path St Vrain Ave Trail Curb Ramp Detectable Wammgs Missing NA 4036166 1055036 side 34 inch miinM1mumam the direction of travel Rd Open the full width of Mel Met street crossing at the snared use path 2011 PR0WAG R2081 DSCR 5700 50001/1/2033-1/1/2038 Finang_63008 8 9 2 9 9110_39a.1pg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Removeand replace[.existing walkway that has an excessive snared Use Pan-Finding827529- Shared Use Path•0g02J529• shared Use Pan-Finding82J529- 393 ADA Evaluation (PAR) Snared Use Pan St Vrain Ave Trail Slope•Cross NA NA NA 0036179 105.5036 The cross slope of pedestrian access routes shall be z percent maximum 520%Open cross slope 2011 PR0W.R302 6 D35 $1,600 $2,0001/1/2033-1/1/2038 20xe,160sq/N Findes_6380889307287_314.). Findmg_63808893080128otza95). FindIng_6380889309018835.1pg The shared use path is not wide enough Pedes tnan Access Routes The continuous clear width of pedestrian access routes shall be 100N minimum exclusive of the width of theShared Use Path•Finding 827530 394 ADA Evaluation (PAR) Snared Use Path St Vrain Ave Trail Continuous Width 120 minimum NA NA 4036295 1055035 curb 60 Open Refer to Record 370 for Reccomendahon and P g 2011 PR0WAG R3023 D25 5 $- 1/1/2033-1/1/2038 Finang_63008893380 _ 21pg Findmg_6380889330807 53 jog Finang_6300ee9339 _ nag The cross slope of the pedestrian access route is excessive Pedestnan Access Routes a and replace the wasting walkway that has an excessive shared Use Pan-Finding 827531- Shared Use Path•Hnding02J531 Shared Use Pan-Finding 827531- Shared Use Hndinge2J531- 395 ADA Evaluation (PAR) Snared UsePan St Vrain Ave Trail Slope•Cross NA NA NA 0036201 1055036 The cross slope of pedestrian access routes shall be z percent maximum 550%Open cross slope 2011 PR0W.R302 6 035 50 SO 1/1/2033-1/1/2038 Finding_6380889326266313.). Findmg_6380889327O8924e1pg Fin g_ 8933 _ e.mg Finding_638012838088933530a3061pg The shared use pa.is not wicle enough Pedes tnan Access Routes The continuous clear width of pedestrian access routes shall be 100N minimum exclusive of the width of tShared Use Path•Finding 827532• 396 ADA Evaluation (PAR) Shared Use Path St Vrain Ave Trail Continuous Width 120 minimum NA NA 0036362 105535 curb Open Refer to Record 370 for Reccomendahon and P g 2011 PR0WAG R3023 D25 5 $ 1/1/2033-1/1/2038 Fin g_ 0089360 _ 51pg Fin g_ 93 08062 _ mgThe surface of the pedestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 Inch and 1/2 inch that are not heeled Pedestnan Routes al Surface surface disco :shall be al surface discontinuities betweenrind down the vertical surface aisantinuities to eliminate the Pan-Finding82J533- 39] ADA Evaluation (PAR)tna Snared Use Pan St Vrain Ave Trail Surface Discontinuities NA NA aD 3632 1055035 and 05 inch shall be beveled with a slope not steeper50 percent The bevel shall be applied across the 15 Open topping hazard 2011 PR0W.R302 7 2 D55 $75 $1501/1/2024-1/1/2027 Fnding_6380e89380685_502.1pg n Access Routes The cross slope of the pedestrian access route is excessive stna replace the existing walkwayexcessivethas an Condos toShared Use Path•Finding 827530Shared Use Path•Finding 827534. 398 ADAEvaluabon (PAR) Snared Use Path St Vrain Ave Trail Slope•Cross NA NA NA 40362e 1055036 The cross slope of pedestnan access routes shall be 2 percent maximum J%Open cross slope 2011 PR0WAG R3026 D35 50 50 1/1/2033-1/1/2038 Community Dr Fin g_ 088935J _ Ipg Fin g_ 0889350 _ rim Fin g_ 088936J _rag Fin g_ 080936e _ in The cross slope of the pedestrian access route is excessive Pede stnan Access Routes Remove and replace the existing walkway that has an excesexcessive From munity Dr to 860 shared Use Pan-Finding 827624- Shared Use Path•Finding027624 a Pan-Finding 82J62a- S. ADA Evaluation (PAR) Snared Use Pan St Vrain Ave Trail Slope•Cross NA NA NA 003655g 1055033 The crass slope of pedestrian access routes shall be z percent maximum 115%3 a% Open cross slope 2011 PR0WAG R302 6 035 SO $D 1/1/2033-1/1/2038 mbar Fin g_ 96ae1 _ J.mg Findmg_63808964e25532261pg Fin g_ 96ae3 _ 5.1pg The cross slope of the pedestrian access route is excessive Petlestnan Access Routes Remove and replace the existing y excessive 6 [has an excess Shared Use Path•Finding 827625• 400 ADA Evaluation (PAR) Snared Use Path St Vrain Ave Trail Slope•Cross NA NA NA 0036598 1055034 The cross slope ofoeaestnan access routes shall be 2 percent maximum 10%Open cross slope 2011 PR0WAG R302 6 D35 53,200 50,8W 1/1/2033-1/1/2038 nose at driveway...Mk Fm g_ 0896a95 _ 9jpg Fin g_ 0303203 _ 1P8 The grade of the pedestrian access route is too step. Pedestnan Access Routes Not WrthinStreet or Hwy Where pedestrian access routes are not contained within a street or highway right-ohwayne grade of and replace.wasting walkway that has an excessive Pan-Finding 827626- Shared Use Path•Finding02J626 Pan-Finding 827626- Shared Use 350933FindingezJ6z6- am ADA Evaluation (PAR) shared Use Pan St Vrain Ave Trail Slope•Running{Grade) ROW NA NA 4036559 1055033 pedestrian access routes shall be 5 percent maximum 12 25%Open running slope 2011 PR0W.R302 5 D35 $4,800 $7,200 1/1/2033-1/1/2038 60xe,480sq/N Fnding_638o89650JJze5J0.). Findmg_63808965005983461pg Fin g_ 96509 _ 2.Ipg Findmg_6380896516335561 ipg Fin The cross slope of the pedestrian access route is excessive Petlestnan Access Routes th replace e existing y excessive 6 Mat an excess Shared Use Path•Finding 837627 6 Shared Use Path•Finding 837627. 402 ADA Evaluation (PAR) Shared U Path St Vrain Ave Trail Slope 33 Cross NA NA NA 0036666 1055 s shall be 2 percent maximum 825%365% Open cross slope 2011 PR0WAG R302 6 D35 $0 50 1/1/2033-1/1/2038 Address760.720 Fin g_ 009652a _ 6jpg Fin g_ 0896525 _ mg g_ 0096532 _ 2jpg Fin g_ 0896533 _ mg The surface of the pedestnan access route haser al diz ont nurties greater than 1/2 inch or between 1/a Inch and 1/2 inch that are not heeled Pedestnan Access Routes Verbmi Surface Vertical surface discontinuities shall be 05 inn maximum Vert.I surface discontinuities between 025 inn shared Use Pan-Finding 82762B- Shared Use Path•Finding027628 Pan-Finding 82J62B- aD3 ADA Evaluation (PAR) shared Use Path St Vrain Ave Trail Surface Dismntinulties NA NA 4036726 1055034 and U S inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 23 multiple locations Open Repair the walkway to eliminate the venal trippers hazard 2011 PR0W.R3027 2 1055 $2,000 $3,0001/1/2024-1/1/2027 25xe,300sq/N Finding_6380896553613667.). Finding_6380896556oB3J1z ipg Fincling_638089655.7600_101.jpg The detectable warning is missing at the curb ramp n Access Routes have detectable warning that extentlsthe full width of the curb ramp excluding the flared able warning surface that extends Shared Use Path•Finding 827620• a. ADA Evaluation (PAR) Shared Shared Use Path St Vrain Ave Trail Curb Ramp Detectable Warnings Missing NA 0036627 1055034 side 24 inch miinimumam the direction of travel Both sides Open the fullawdth of Mel Met street crossing at the snared use pan 2011 PR0WAG R2081 DSCR 5]00 50001/1/2033-1/1/2038 Fin g_ 00965]6 _ Ipg Finding_6380896577590_221 ipg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive snared Use Pan-Finding827630- Shared Use Path•000352g02J630• shared Use Pan-Finding827630- Shared Use 550935 Finding 8zJ630- a05 ADA Evaluation (PAR) Shared Use Pan St Vrain Ave Trail Slope-Goss NA NA NA 4036802 1055036 The crass slope of pedestrian access routes shall be 2 percent maximum 7,3.3% Open cross slope 2011 PR0W.R3026 D35 SO SO 1/1/2033-1/1/2038 650 to Graves Finding_6380896579752853.). Findmg_638089658033z J06ips FindIng_6380896585930307.Ipg Findin0_63808965866839.ipg The cross slope of the pedestrian access route is excessive (PAReR) replace Me existing Access Routes Walkways Performance Park Slope 39 Cross NA NA NA 0037719 105 cross slope of pedestrian access routes shall be 2 percent maximum 7%Open cross slope y tM1as an excessive 2011 PR0WAG R3026 B35 54,000 56,0001/1/202J-1/1/2033 00x10,3Wsq/N Fin g_ 0890038 _ 1.mg Findmg_6380890o392a0ays-Finding 3 a06 ADA Evaluation 243 jpg Fin g_ 00 009ae _ ms e Fin g_ 89 000a9 _ me The surface of the pedestnan access route has vernal discontinuities greater than 1/2 inch or between 1/4 Inch and 1/2 inch that are not heeled Pedestnan Access Routes Vertml Surface Vertical surface discontinuities shall be al surface es betweenrind down the vertical surface discontinuities to eliminate the Walkways•Finding 827536- Walkways 407 ADA Evaluation WAR) Walkways Performance Park Surface Dieannnulhes NA NA 0037733 105529 and U 5 inch shall be beveled with a slope not steeper 50 percent The bevel shall be applied across the 2"multiple locations Open topping hazard 2011 PR0W.R302]2 B55 $75 $1501/1/20b-1/1/2027 Findes_6380890050614_790.Ipg Finding_63808900521J83852 r. The cross slope of the pedestrian access route is excessive The pedestrian Pedestnan Access Router s our that the 2 a%cross slope falls within Walkways•Finding 827537- Walkways-Finding 827537• 408 ADA Evaluation (PAR) Walkways Performance Park Slope•Goss NA NA NA 003]R2 1055289 The crass slope of cedetnan access routes shall be 2 percent maximum 2a0%Open conventional construction tolerance No arnon required 2011 PR0WAG R3026 B35 $0 $D 1/1/2027-1/1/2033 Fin g_ 90063 Boa ipg Findmg_6380890064571575 jpg The surface of the pedestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface ,krtualsorface diuontinutes shall be 0 3 inch maximum Vertical surface discontinuities between 0 2S inch Grind clown.e vertical surface discontinuities to eliminate the Walkways•Finding 827538- 409 ADA Evaluation (PAR) Walkways Performance Park Surface Discontinuities NA NA 40 37713 -105 5289 and 0 5 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the V' Open Mop,hazard 2011 PROMS R302 7 2 8.5.5 $75 $130 1/1/2024-1/1/2027 FindIng_6380890069080_132..ips The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Walkways•Finding 827539• Walkways-Finding 827539• 410 ADA Efaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 00 37705 .105 5288 The cross slope of pedestrian access routes shall be 2 percent maximum 3 30%Open cross slope 2011 PROWAG R302 6 8.3.3 5330 5525 1/1/2027-1/1/2033 715',352q/ft Pmding_6380890074891_576.1pg Rinding_633080007S681-791 in8 The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface ,krtualsorface diuontinutes shall be 0 S inch maximum Vertical surface discontinuities between 0 23 inch Grind clown.e vertical surface discontinuities to eliminate the Walkways•Finding 827540- 433 ADA Evaluation IPAR) Walkways Performance Park Surface Discontinuities NA NA 40 37704 -105.5288 and 0 5 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the V' °Pen InppIng hazard 2011 PROMS R302 7 2 8.5.5 575 $130 1/1/2024-1/1/2027 FindIng_6380890081965_316,pg The cross slope of Me pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Walkways•Finding 827541• Walkways-Finding 827541• Walkways•Finding 827541. Walkways-Finding 827541• 412 ADA Evaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 00 37712 .105 5286 The cross.slope of pedestrian access routes shall be 2 percent maximum 5 65%Open cross slope 2011 PROWAG R302 6 8.3.3 50 50 1/1/2027-1/1/2033 35,7.Flagstone r.,ding_63goggoogg03,g7g,pg Finding_6380,390088843_775 jpg Pmding_6380890092459_6721pg Rindin3_633089000.9.-0e.in8 The cross slope of Me pedestrian access route is dcesswe Pedestrian Access Routes R...3,em:v3,eopareld replace the existing walkway that has an excessive Walkways•Finding 827542- Walkways-Finding 827542• Walkways•Finding 827502- 413 ADA Evaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 00 37719 -105 5286 The cross slope of pedestrian access routesshall be 2 percent madmen 3 33%°per, 2011 PROW.R302 6 8.3.5 50 50 1/1/2027-1/1/2033 20,'to accessible picnic table F2)dIng_6380890102474_990,pg Finding_6380890106163_433,23 Fi02i48_6380890106805_560,,pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface Vertical surface diuontinuites shall be 0.5 inch maximum Vertical surface discontinuities between 0 2.5 inch Multiple Inning hazards at Remove existing flagstone,level surface and re-install flagstone Walkways•Finding 827543. Walkways-Finding 827543• 410 ADA Evaluation (PAR) Walkways Performance Park Surface Discontinuities NA NA 40 37714 .105 5287 and OR inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the flagstone Open to eliminate tripping hazard 2011 PROWAG R302 7 2 85.3 5130 5300 1/1/2024-1/1/2027 Sm2i9g_6380890113079_377mg 50170g_6330600114650-683 ing The grade of the pedestrian access route is too steep. Pedestrian Access Routes Not Within Street or Hwy Where pedestrian access routes are not contained within a street or highway righeof•way Me grade of Remove and replace the.sting walkway that has an excessive Walkways•Finding 827541- Walkways-Finding 827S44- 410 ADA Evaluation (PAR) Walkways Performance Park slope•Running{Grade) ROW NA NA 40 37708 -105 5284 pedmtnan access 740030 shall be 5 percent maximum 8 35%at flagstone Open running slope 2011 PROWAG 5342 5 8.3.5 51,920 $2,400 1/1/2027-1/1/2033 8112,96sq/ft FindIng_6380890130319_890,pg Find2t63808901.31175_533 jpg The cross slope of the pedestrian moms route is ewesswe Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Walkways•Finding 827505- Walkways-Finding 827545• 416 ADA Evaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 00 37708 .105 5284 The cross slope of pedestnan access routes shall be 2 percent maximum ill Open cross slope 2011 PROWAG R302 6 83.3 51,000 51,500 1/1/2027-1/1/2033 2045',1000q/ft Finding_6380890136203_1351pg Rindin3_6330800137037-301 in8 The surface of the pedestnan access route has vertIcal discontinuities greater than 1/2 inch or between 1/4 In.and 1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface Vertual surface dIscontmuites shall be 0 S inch maximum Vertical surface discontinuities between 0 23 inch Walkways•Finding 827547- Walkways-Finding 827S47• Walkways•Finding 827547- 418 ADA Evaluation (PAR) Walkways Performance Park Surface Discontinulties NA NA 00 37689 -105 5286 and 0 5 in.shall be beveled with a slope not steeper than 50 percent The bevel shall I.applied across the V'and damaged concrete Open Remove and rep...sting walkway 2011 PROWAG 5342 7 2 8.5.5 51,680 $2,520 1/1/2024-1/1/2027 14,2%16aq/ft FindIng_6380890167769_931.jpg Finding_6380890148940_140,pg Fin2I3g_6380890152466_5864pg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that the 2 4%cross slope falls within Walkways•Finding 827549. Walkways-Finding 827.549• 420 ADA Evaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 00 37707 .105 5283 The cross slope of pedestnan access routes shall be 2 percent maximum 2 40%Open conventional construction tolerance No action required 2011 PROWAG R302 6 83.3 50 50 1/1/2027-1/1/2033 Fmdi4g_6380890170034_943mg Rinding_638060017062e-137 in8 The surhu of the 734810010 access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mm(0 5 in)in Walkways•Finding 827550- 421 ADA Evaluation (PAR) Walkways Performance Park Surface Horizontal Openings Greater Than 1/2 Inch NA 00 37717 -105.5279 diameter Open Repair the walkway to eliminate openIngs and Inpping hazard 2011 PROW.R302 7 3 8.5.5 5100 $150 1/1/2024-1/1/2027 FindIng_6380890172874_4160pg Ifie crow slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Walkways•Finding 827551- Walkways-Finding 827551• Walkways•Finding 827551- Walkways-Finding 827331• 422 ADA Mluation (PAP) Walkways Performance Park Slope•Cross NA NA NA 00 37714 -105 528 The cross slope of pedestnan access routes shall be 2 percent maximum 3 55,3 3% Open cross slope 2011 PROWAS 8302 6 83.6 81,920 $2,880 1/1/2027-1/1/2033 2448',192sq/ft Fm2i4g_6380890179234_317rpg .0,4_6380890179920_551 ips Finding_6380690164511_31 08 Findi,6380690165067_717 in The crow slope of Me curb ramp is greater than Me grade of Me street Pedestrian Access Routes Perpendicular or Diagonal The cross slope of curb ramp at the pedestrlan street crossings without a yield or stop control shall be 3 05%wlthin sste not Reconstruct curb ramp to provide a cross slope grade less than or 423 ADA Evaluation (PAR) Walkways Performance Park Curb Ramp Slope-Cross Onene Ramp ma P693 -105 5282 permitted to equal the street or highway gmde PROW Open equal to 2% 2011 PROW.R300 5 3 8.2.CR $3,000 $3,500 1/1/2027-1/1/2033 The cross slope of Me turning space exceeds 2%maximum The cross slope of curb ramps blended transitions and turning spaces shall be 2 percent maximum At Pedestrian Access Routes WM Yield or Stop pedestrian street crossings without yield or stop control and at inidblock pedestnan street crossings the cross 3 06 within site not Regnde the turning space of the curb nmp,so that the cross Walkways•Finding 827553- Walkways-Finding 827353• 420 ADA Evaluation (PAR) Walkways Performance Park Curb Ramp Turning Space Slope-Cross Controls 40 37693 .105 5282 slope shall be pennitted to equal the street or highway grade PROW Open slope does not exceed 2% 2011 PROWAG R304 5 3 84.CR 51,000 51,500 1/1/2027-1/1/2033 Pmding_6380890206046_676.1pg Fleding_633060020eS1,-S,,%0 The running slope of the turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regrade the turning space of the curb ramp,so that Me running Walkways•Finding 82755S- Walkways-Finding 827SS5- Qs am Evaluation (PAR/ Walkways Performance Park Curb Ramp Turtling Space Slope-Running Perpendicular Rarnp 40 37675 -105.5279 shall be S.percent minimum and 8 3 perce.maximum but shall not require the ramp length to exceed 15ft 3 4511 Open slope does not exceed 2% 2011 PROW.R300 2 2 134.CR $1,000 $1,500 1/1/2027-1/1/2033 FindIng_6380890217830_121,pg Finding_6380890218488_859 mg Ifie cross slope of the pedestrian moms route is excessive Pedestrian Access Routes Remove and replace.existing walkway that has an excessive Walkways•Finding 827556- Walkways-Finding 827.536• 427 ADA Evaluation (PAR) Walkways Performance Park Slope•Cross NA NA NA 40 37694 .105 5283 The cross slope of pedwtnan access routes shall 342 percent maximum 4 70%Open crow slope 2011 PROWAG R302 6 113, 52,030 53,000 1/1/2027-1/1/2033 2348',200sq/ft Fin2i4g_6380890229730_909r7g Finding_6380890230628_313 ins The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excess. Sidewalk-Finding 827357. Sidewalk-Ending 827537- Sidewalk-Finding 827357. Sidewalk•Finding 827537- 428 ADA Evaluation (PAR) Sidewalk Spruce Or Slope•Cross NA NA NA 00 37691 .105 5273 The cross slope of pedestrian access routes shall be 2 percent maximum 5 15%at Curb ramp Open cross slope 2011 PROWAG R302 6 0.5 $4,000 56,000 1/1/2033-1/1/2038 50,8',400sq/ft Fin04g_6380890250902_18103 F0ding_6380890252067_8161pg Fin 290g_6380890254214_1414pg Finding_63808902.56086_68 jpg The running slope of pedestrian access route exceeds the general grade of the ad,acent street of highway Pedestnan Access Routes Withln Street or Hwy Where pedestrian access routes are contained within a street or highway right.of-way the grade of Reconstruct curb ramp to provide a runnIng slope grade less Man Sidewalk-Finding 827558• Sidewalk•Finding 827538- 429 ADA Evaluation (PAR) Sidewalk Spruce Or SloPe•Running{Grade) ROW NA NA 40 37686 -105 5273 pedestrian access routes shall not exceed the general grade established for the adiacent street or highway 9%Open or equal to 8 3% 2011 PROW.R302 5 CO-S $3,000 $3,500 1/1/2033-1/1/2038 Fin2i4g_638089026.3332_53.35..ips Fin10ng_6380890266173_283 jpg The running slope of the curb ramp is excessive Pedestrian Access Routes Perpenduular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent rnaminum but shall not Reconstruct curb ramp to provide a runnIng slope grade less Man 2011 PROWAG R304 2 2 Sidewalk-Finding 827S62• Sidewalk-Ending 827562- 431 ADA Evaluation IPAR) Sidewalk Spruce Dr Curb Ramp McRae-Runmng(Grade) Rarnp NA 00 37723 -105 527 require the rarnp length to exceed 15.0 ft 11 90%Open or equal to 8 3% 2011 PROWAG R300 3 2 62.CR $3,000 $3,500 1/1/2033-1/1/2038 Fin2i4g_638089028.300.3_331..ips Find0g_6380890283976_3451pg The running slope of Me turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or shall he built up to the curb at right angles or shall Pedestnan Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regrade the turning space of the curb ramp,so that the running Sidewalk-Finding 827S63• Sidewalk•Finding 827563- 432 ADA Efaluation (PAR) Sidewalk Spruce Dr Curb Ramp Turning Space Slope-Running Perpendicular Ramp 00 37725 -103 S27 shall he S.percent minimum and 8 3 percent maximum but shall not require the ramp length to exceed 15ft 3 90%Open slope does not exceed 2% 2011 PROWAG R304 2 2 COCK 51,000 $1,500 1/1/2033-1/1/2038 002i9g_6380890287263_4051pg Pindin3_63308002..8e-08.in. 1.naming slope of pedestnan access route exceeds the general grade of the adjacent street of highway. Pedestnan Access RoMes Within Street or Hwy Where pedestrian access routes are contained wIthin a street or hIghway rIghtmferray the grade of Remo.and replace the.sting watkway Mat has an excessive Sidewalk-Finding 8275.. Sidewalk-Ending 827564- 433 ADA Evaluation WAR) Sidewalk Spruce Or SloPe•...ins{Grade) ROW NA NA 40 37711 -105 5281 pedestrian access routes shall not exceed the general grade establehed for the adiacent street or highway 1030%Open running slope 2011 PROW.R302 5 CO-S $800 $1,200 1/1/2033-1/1/2038 1033b 80sq/ft FindIng_6380890293314_3574pg Find0g_6380890294055_427 pg The surface of the pedestrian access route has vertical discontinuities greater.an 1/2 inch or between 1/4 in.a.1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface Vertical surface diuontinuMes shall be 0 3 mch maximum Vertical surface discontinuities between 0 2.5 inch Grind down.e vertical surface discontinuities to eliminate the Sidewalk-Finding 827S66• 435 ADA Efaluation (PAR) Sidewalk Spruce Dr Surface Discontinuities NA NA 40 37693 .105 5272 a.0 5 inch shall be beveled w.a slope not steeper than 50 percent The bevel shall.apphed across the 1. C." tOPPing hazard 2011 PROWAG 8302 7 2 CO-S $75 $150 1/1/2024-1/1/2027 Fin2i4g_638089030.3401_989.1pg The cross slope of the pedestrian access route Is excessive Pedestnan Access Routes Remove and replace the existing walkway Mat has an excessive Sidewalk-Finding 827567. Sidewalk-Finding 827567- 436 ADA Evaluation IPAR) Sidewalk Spruce Or Slope•Crow NA NA NA 00 37693 -105.5272 The cross slope of pedestrian access routes shall be 2 percent maximum 6 70%Open cross slope 2011 PROWAG R302 6 0.5 50 $0 1/1/2033-1/1/2038 FindIng_6380890310010_7124pg Findmg_6380890311141_529 jpg The running slope of the turning space at the top of the curb ramp exceeds 2%.mammon The running slope of the curb ramp shall cut through or shall he built up to the curb at right angles or.11 Pedestrian Access Routes meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Regrade the turning space of the curb nmp,so that the running Sidewalk-Finding 827568. Sidewalk•Finding 827568- 437 ADA Efaluation (PAR) Sidewalk Spruce Dr Curb riamP Turning SP.,. Slope-Running Perpendicular Ramp 40 37675 .105 5272 shall be S.percent ininimurn and 8 3 percent maximum but shall not require the ramp length to exceed 15ft 5 90%Open slope does not exceed 2% 2011 PROWAG R304 2 2 COCK 51,000 51,500 1/1/2033-1/1/2038 Fin2i9g_6380890320180_932 mg Finding_6380890321275_637 jpg . The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway Mat has an excessive Sidewalks-Finding 827570- Sidewalks-Finding 827570- 440 am Evaluation IPAR) Sidewalks Spruce Parking Sop.-Crow NA NA NA 00 37676 -105 5271 The cross slope of pedestrian access routes shall be 2 percent maximum 3 4%damage from tree Open vow slope 2011 PROW.R302 6 8.3.5 $1,800 $2,700 1/1/2027-1/1/2033 3030',180sq/ft FindIng_6380890340512_88507g Find03_6380890341369_959 mg The surface of the pedestdan access route has veMcal discontinuities greater than 1/2 inch or between 1/4 inch a.1/2 inch that are not beveled Pedestnan Access RoMes Vertical Surface Vertical surface discontinuities shall be 0 5 inch maximum Vertical surface discontinuities between 0 25 inch Grind down Me veMcal so..discontmuMes to eliminate the Sidewalks-Finding 827571- 441 ADA Evaluation (PAR) Sidewalks Spruce Parking Surface Deco.nuibes NA NA 40 37671 .105 5269 and 0 5 inch shall be beveled w.a slope not steeper than 50 percent The bevel Mall be applied across the 1. C." 10POng hazard 2011 PROW.R302 7 2 135, $75 0170 1/1/2024-1/1/2027 Fi02i9g_6380890307653_714.34 The grade of the pedestrian access route is too steep. Pedestnan Access Routes Not Within Street or Nwy Where pedestrian access routes are not conMned wrtIon a street or highway ogheof•way Me grade of Remove and replace the existing walkway Mat has an excessive Sidewalks-Finding 827609- sidewalks-Finding 827609- .2 ACM Evaluation (PAR) Sidewalks Spruce Parking SloPe•Running{Grade) ROW NA NA 00 37685 -105.5267 pedestrian access routes shall be S percent maximum 12%Open running slope 2011 PROW.5304 5 8.3.5 51,200 Stew 1/1/2027-1/1/2033 12930%120sqfft FindIng_6380890367488_8824pg .603_6380890368867_560 jpg The cross slope of Me pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excess. Sidewalks-Finding 827610- Sidewalks•Finding 827610. 443 ADA Evaluation (PAR) Sidewalks Spruce Parking Slope•Cross NA NA NA 40 37683 .105 5266 The cross slope of pedestnan access routes shall be 2 percent maximum 6%Open cross slope 2011 PROWAG 8302 6 83.5 $0 50 1/1/2027-1/1/2033 Pm2i9g_6380890374189_206 log Finding_633060.74935-7/P8 The crow slope of the usrb ramp is greater than the grade of Me street The curb mrnp does have an excessive cross slope However,a is Pedestrian Access Routes Wrthout Meld or Stop Perpendicular.'Diagonal The cross slope of curb ramp at the pedestrlan street crossings without a Geld or stop control shall be our minion that the cross slope of 2 6%falls within conve.ional Sidewalks-Finding 827611- sidewalks-Finding 827611- 444 ACM Evaluation (PAR) Sidewalks Spruce Parking Curb Ramp Slope Cross Controls Ramp 4047071 -105.5267 permitted to epual the street or highway grade 2 60%Open construction tolerance No action required 2011 PROMS R300 5 3 8.2.CR 1/1/1327-1/1/2033 Fin2i9g_6380890380153_4124pg 61.1,6380890381201_27S. The running slope of the turning space at the top of the curb amp exceeds 2%maximum The running slope of the ramp shall cut through or shall be built up to the curb at right angles or shall Pedeztnan Access Routes meet the gutter grade break t right angles where the curbs cured The running slope of the curb ramp Regrode the turning space of the curb ramp,so that the running Sidewalks !nano827612- 6inding827612. 443 ADA Evaluation (PAR) SidewalksSprucePar g Curb Ramp Turning Space Slope-Running Perpendicular Ramp 0037692 1055267 shall be 5 percent minimum and 83 percent maximum but shall not require the ramp length to exceed 15ft 5 90%Open slope does not exceed 2% PROWAG R30022 Ba•CR $1,000 51,5001/1/2027-1/1/2033 Fin 8 g_ 08303 _ 1IPg Findng_6380890387238101 jpg IMMIIIII The cross slope of the pedestrian across route is excess. Pedeztnan Access Routes Remove and replace the casting walkway that has an excessive Sidewalks-F!nano 827613- sidewalks-finding 82]613- Sidewalks-F!nano 82]613- .6 ADA Evaluation (PAR) Sidewalks Spruce Parking Slope•Cross NA NA NA aD 3768 1055267 The cross slope of pedestrian access routes shall be 2 percent maximum 500%Open cross slope 2011 PROW.R302 6 B35 $1,200 $1,800 1/1/2027-1/1/2033 ]Sate,120sq/h Finding_6300890390198_398.IPg Fnding_63808903913261321pg Fintling_6300890392021998.ipg The surface of the pedestrian access route has vertical discontinumes greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Pedez nAccess Routes cel Surface al surface hall be gal surface sbetwe rind down the vertical surface disonnunies to elinnate the Sidewalks- ang830363- a08 ADA Evaluation (PAR) Sidewalks SidewalksSprucePar g Surface Dnc.ntinutes NA NA 52 slope maximum 50 percent The bevel shall be applied across Me 1 Open pp a hazard 2011 $75 51301/1/2024-1/1/2027 Fin g_ 089030] _amg Ilr 5 69 The3Umche moinbmum14,8ticheslmmimumtclearfloor space required at Me pushbutton is consistent PROW. wrtM1 Me gatle of Me adlace pe rtran access route Accessible PedestnanSignal Slope-Parallel to the Changes in level are not permitted at required 118233oor or ground space except that slopes not steeper than Regnde concrete at We accessible pedestrian signal so that We East Sidewalk-Finding 827633- Eastsidewalk•finding 82]633- .52 .A Evaluation (AP3) East Sidewalk SSt Vrain Ave Clear Floor Space Pedestrian Access Route NA NA 4036919 -105.5043 1 08 shall be permitted 715%Open running and cross slope do not exceed 2% 2011 PROWAGR0002 A35 $1,000 $1,5001/1/2027-1/1/2033 FindIng_638089667716164Ipg Fndmg_63808966785008621pg The running slope of Me turning space at the top of the curb amp exceeds 2%maximum The running slope of the Curb minp shall cut through or shall be built up to the curb at right angles or shall Pedestrian Access Routes r The running slope of the curb ramp grade the turning space of the curb amp,so that the running stSidewalk-Fnding82]63] 333333indmg82]63]- Ws ADA Evaluation (PAR) East Sidewalk SSt grain Ave Curb Ramp Turning Space Slope-Running Percentleular Ramp 550.shall be 5 percent minimum and 83 percent maximum but shall otreguire the ramp length to exceed 15ft 13% p slope does not exceed 2% .R30022 AOCR $1,000 51,5001/1/2027-1/1/2033 Pmdng_6300896I15835_3a]I. Fndng_638089e]1e373-.9jP8 illa1 The running slope of pedestrian access route exceeds the general grade of the adlacent street of hghway. -ROW Pedeztnan Access Rauas Within Street ex Hwy Where pedestrian access routes are contained within a street s highway right-of-way the grade of Remove and replace the wasting walkway that has an excessive East Sttlewalk-Finding 827638 East Sidewalk•finding 82]638- .6 ...legion (PAR) East Sidewalk SSt grain Ave Slope Renning{Grade) ROW NA NA 4037001 1055047 pedesrian access routes shall net exceed the general grade established for the adlacent street or highway 1440%Open running slope 2011 PROW.R302 5 A35 $6,500 $6,]301/1/202]-1/1/2033 75Sp50sq/ft Fin g_ 96I21 _ 1.IPg Findmg_63808967223096091pg n Access Routes The cross slope of the pedestrian access route is excessive replaceRemove and the existing walkwayexcessiveChas an ewalk-Finding 827640 Finding 827600. 458 ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Slope•Cross NA NA NA 0036956 105500a The crass slope of pedestrian access routes shall be 2 percent maximum 320%Open cross slope 2011 PROWAG R3026 A35 $1,000 51,500 1/1/2027-1/1/2033 2033,100zg/ft Flndng_6300896I05338_909I14 Findmg_6380896745 _ Ipg The running slope of the right curb ramp is excessive Pedeztnan Access Rgttes The running slope of the curb amp shall be 5 percent minimum and 0.3 percent maximum but Wall not Reconstruct curb rap to provide a running slope grade less Man 2011 PROW.R30022 EastSidewalk-Finding 82]W3- East Sidewalk•Finding 827641- EastSidewalk-Finding 82]W3- .9 .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Curb Ramp Slope-Runnmg(erade) Parallel Ramp Right Ramp 4036960 1055046 require the ramp length to exceed 15.0ft 1130%Open or equalto 8 3% 2011 PROW.R30032 A3CR $3,000 $3,5001/1/2027-1/1/2033 FindIng_6300e96]636]5811.IPg Fndmg_63808967607087961pg Finding_6380896766075_738ttag n Access Routes The cross slope of roe pedestrian access route is excessivePedessna replaceRemove and Me existing walkway Mathas an excessive East Sidewalk-Finding 827643 Finding 827603 ewalk-Finding 827643 Finding 827643• ae1 ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Slope•Cross NA NA NA 00370]a 105 5034 The cross slope of pedestrian access routes Wall be 2 percent maximum 15%33% Open cross slope 2011 PROWAG 33026 A35 $7,500 $11,2501/1/2027-1/1/2033 150%5,730sq/ft Findn_6300896I8900930 mg Rn g_ 0896]89 _ 1pg Fin g_ 0896800 _ 9 Ill Fin g_ 0896801 _ 1P8 The surface of the pedestrian access route has vertical m l discontinues greater than 1/2 inch or between 1/0 a inch and 1/2 inch that are not beveled Pedez nAccess Routes cel Surface nil surface shall be cel surface rind down the vertical surface discontinuities to eliminate the .walk-F Finding 462 ADA Evaluation (PAR) East East Sidewalk 5St Vradn Ave Surface Disconmulties Na Na 0037158 1055061 and 05 inch shall be beveled with a slope enot steper1than 50 percent The bevel shall be apped across We 1 Open mppdng hazard 2011 PROW.R3027 2 A55 $75 $1301/1/2024-1/1/2027 Finding_6380896817678_974,. The running slope of Me right curb ramp is excessive n Access Routes slope of the curb amp shall be 5 percent minimum and 83 percent maximum but shall not e p provide a running p th grade less an 20 ewalk-Finding 829623 Finding829623S ewalk-Fning829623• 463 ADA Evaluation MAR) East Sidewalk 5St grain Ave Curb Ramp Slope Runing(Grade) Parallel Ramp Right.11, ao 37169 •1055061 require the ramp length to exceed 150 ft 10%Open or equal to 83% 2011 PROWAG R304 32 A2CR $3,000 53,500 1/1/2027-1/1/2033 Pmdng_6300896837451864 Ipg Fntlmg_63808968306]0_ mg Dittin8_6380895839207_336 WC The cross slope of roe pedestrian across route is excessive n Access Routes a and replace the wasting walkway that has an excessive stSidewalk-Fndng82962l Sidewalk•Finding 829625- stSidewalk-Fndng82962l ewalk•Findmg829625- a65 ADA Evaluation (PAR)) East Sidewalk SSt Vradn Ave Slope•Cross Na NA Na 4037173 1055063 The cross...of pedeMan access routes shall be 2 percent maximum 365%Open cross slope 2011 PROW.R302 6 A35 $2,500 $3,]301/1/202]-1/1/2033 SOS,250sq/ft Fin g_ 96853 _ ].IPg Fndg_638089685003D5561pg Fin g_ 9685] _SD.IPg Fndmg_6380896850a92a081pg The running slope of Me nght curb ramp is excessive Pedestnan Access Routes The running slopeof the curb amp shall be 5 percent minimum and 83 percent maximum but shall not Reconstruct curb ramp to provide a running slope grade less than 2011 PROWAG R304 2 2 East Sidewalk-Finding 829626 ass ADA Evaluation (PAR)) East Sidewalk 5St grain Ave Curb Ramp Slope Run Illg(Grade) Paallel Ramp Right Ramp 0037187 1055064 require the ramp length to exceed 150 ft 1130%Open or equal to 83% 2011 PFOWAG R30432 A2CR $3,000 $3,500 1/1/2027-1/1/2033 Pmdng_630089686389]_]18 IJ. Fntlmg_6380896860959_5I91P8 The cross slope of the turning space exceeds 2%maximum The c sslope of curb ra sblen s hall bet percent mximum At Pedeztnan Access Routes With Yield or Stop pedestrian street crossings without weld or stop control and at matlblock pedestrian street crsxngs the cross gade the turning space of Me curb amp,so that the cross stSidewalk-Fndng82962I 333353indmg82962]- a6] .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Curb Ramp Turning Space Slope-Cross Controls 4037197 1055 5 slope shall be permitted to equal Me street.'highway grade 635%Open slope does not exceed 2% 2011 PROW.R30053 AO-CR $1,000 $1,5001/1/2027-1/1/2033 Fin g_ 968]3 _ ].IPg Fndn'g_63808968]0]262151pg The 30 inches minimum by 48 i minimumclear floor space required at the pushbutton is consistent with t g e of Me adlacen pedegan access route Accessible Pedestrian gnal Slope-Parallel to the Changes in level are not perrotted at q th required floor or ground space except roar slopes not steeper Regrode concrete at the accessible pedestrian signalso that the Sidewalk ding 829620 finding829628. 468 ADA Evaluation (APS) East Sidewalk 5St grain Ave Clear Floor Space Pedestrian Access Route NA NA ao 3719e 1055054 108 shall be permitted ]85%Open running and cross slope do not exceed. 2011 PROWAG R404 2 A35 51,000 51,500 1/1/2027-1/1/2033 F0dng_63808358008968]9 _ 2lpg Fin g_ 06968]9]S7-Sa61Pg The naming slope of the right curb ramp is excessive Pedeztnan Access Routes The running slope of the curb amp shall be 5 percent...urn and 8.3 percent maximum but Wall not p to provide a running slope grade less Man 2011 PROW.R30022 stSidewalk-Fndng829630 tSidewalk•Findmg829630- a]0 .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Curb Ramp Slope-Runnmg(erade) Parallel Ramp Right Ramp 0037204 1055066 require We ramp length to exceed 100 ft 10 55%Open or equal rto c3%ra 2011 PROW.R30032 A2CR $3,000 $3,5001/1/2027-1/1/2033 Fin g_ 96899 _ ].IPg Fndmg_63808969088132751pg The cross slope of roe turning space exceeds 2%maximum The cross slope of curb ons and n Access Routes or Stop sings ramps loutyeld or stop turning maximum op control and at miitlblock petlestrian streetcrossings Me cross Regrade Me turning space of the curb ramp,so that the cross East Sidewalk-Finding 82963] Finding82963]. 471 ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Curb Ramp Turning Space Slope Cross Controls 0037233 1055068 slope shall be pen.to equal the street o highway gatle 9%Open slope does not exceed 2% 2011 PROW.330053 AOCP $1,000 51,5001/1/2027-1/1/2033 Fn g_ 089690a _ Olpg f1.1^6_636060S305.5-3.1P8 The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessrv.cross slope Pedeztnan Access Routes ropinmn that the 26%cross slope falls within stSidewalk-Fndng82963I 333353indmg829639- a]3 .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Slope•Cross NA Na NA 0037291 1055073 The cross slope of pedeMan access routes shall be 2 percent maximum 2 60%Open conventional constructiontolerance No anon required 2011 PROWAG 33026 A35 50 $01/1/2027-1/1/2033 Fin g_ 9692 _ 6.IPg Fndmg_63808969296869921pg n Access Routes The cross slope of Me pedestrian access route is excessivePede replaceRemove and Me existing y Mat has an excessive Finding 829600• 470 ADA Evaluation (PAR)) East Sidewalk 5St grain Ave Slope•Cross NA NA NA 0037288 1055073 The cross slope of pedestrian access routes shall be 2 percent maximum 91%drive pan Open cross slope 2011 PROWAG 33026 A35 $1,500 $2,250 1/1/2027-1/1/2033 305,150sg/ft Fn g_ 089690 _63opg Fin g_ 08969a62]9_9581P8 The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessrv.cross slope Pedeztnan Access Routes However,it s ropinmn that MM1e26%cross slope falls within ewalk-Fndng8296a1Sidewalk finding a75 .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Slope•Cross NA Na NA 4037312 105507S The cross slope of pedeMan access routes shall be 2 percent maximum 260%Open conventional construction tolerance No anon required 2011 PROW.R3026 A35 $D $D 1/1/2027-1/1/2033 Fin g_ 96961 _ 3.IPg Fndng_33338363808969623153]51pg The cross slope of Me pedestrian access route is excessive The pedestrian access route does have an excessive cross slope tna n Access Routes However,it is our opinion that the 2]%cross slope falls within Finding 829605 478 ADA Evaluation IMP) East Sidewalk 5St grain Ave Slope•Cross NA NA NA 0037323 1055 maximum 2]0%Open conventional construction tolerance No action required 2011 PROWAG 33026 A35 $0 $01/1/2027-1/1/2033 Fin g_ 0896990 _ Olpg Fin g_ 0696991 _ 1P8 ]6 The cross slope of the turning space exceeds s2%maximum ent The c sslope of curb ra sblended to hall bet percent mximum At Pedeztnan Access Routes With Yield or Stop pedestrian street risings without weld or stop control and at roadblock pedestrian greet crssngs the crass Regale the turning space of Me curb ramp,so that the cross East Sttlewalk-Finding 8296a] 333313inding8296a]- a80 .A Evaluation (PAR) East Sidewalk SSt Vradn Ave Curb Ramp Turning Space Slope-Cross Controls 003I0 1055083 slope shall be pennted to equal the street or highway grade 070%Open slope does not deed 2% 2011 PROW.R30053 AO-CR $1,000 $1.01/1/2027-1/1/2033 Fin g_ 9]019 _a.IPg Fndn'g_638089I0199a16201pg The surface of the pedestrian access route has openings greater Wan 1/2 inch n Access Routes ewalk-Fnding829648• an ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 403I002 1055084 diameter openings gratings pints Wall vas permitw passage of a sphere more than 13 min 105 n)in 15 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PROWAG R3027 3 A55 $100 $1301/1/2024-1/1/2027 Finding_6380897022336_9451. The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedez nAccess Routes ropro nMat s slope falls within Sidewalk-Finding 8296a9 333353inding8296a9- ae2 ...legion (PAR) East East Sidewalk SSt Vradn Ave Slope-Cross Na NA NA 0037417 105.5086 The crass slope.(pedestrian access routes shall be 2 percent maximum 225%Open conventional constructiontolerance 2No anon required. 2011 PROW.R3026 A35 $0 $D 1/1/2027-1/1/2033 Fin g_ 9]02 _ 3.IPg Fndmg_638089I0301]]e]91pg The running slope of pedestrian access route exceeds Me geneml grade of Me azbacent street.(highway n Access Routes Street or Hwy withintrot-way Me grade of . replace Me existing walkway Mat has an excessive ewalk-Finding 829650 4e3 ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Slope Run ing decade) ROW NA NA 403I037 1055087 pedestrian access routes shall not exceed the general grade street for theadjacent street or highway 12 25%Open running slope 2011 PROWAG 33025 A35 $1,000 $1,5001/1/2027-1/1/2033 10%10,100sq/ft Fin g_ 089]038 _ 2lpg Fin g_ 089I039 _ 1P8 The cross slope of the curb amp n greater than 2%. Pedeztnan Access Routes Wrth yield or Stop Perpendicular or Dag.nal curbr p to provide a cross slope grade less than or stSidewalk-Fndng829651 333355inding829651- a04 ADA Evaluation (PAR) East Sidewalk SSt Vradn Ave Curb Ramp Slope-Cross Controls p 403I069 105.5089 The cross slope.(curb ramps blended transitions and turning spaces shall be 2 percent maximum 655%Open equal to 2% 2011 PROW.R304 53 A2CR $3,000 $3,500 1/1/2027-1/1/2033 Fin g_ 9]005 _ 7,6 Fndmg_638089]oa6]123691pg The cross slope of Me turning space exceeds 2%maximum The cross slope of curb ramps blended transitions and turning spaces shall be 2 percent maximum A n Access Routes or Stop a itlblock pedestrian street . g Me cross space of the curb ramp,so that the cross ewalk-Fning829652 finding 829652• am ADA Evaluation (PAR)) East Sidewalk SSt grain Ave Curb Ramp Turning Space Slope Cross Controls 00370]a 105509 slope shall be permitted to equal the street o g V essdv 935%Open slope does not exceed. 2011 PROWAG R30453 AOCR $1,000 $1,5001/1/2027-1/1/2033 Fin g_ 089]0d9 _ Olpg f1.1^6_63606570,0570-535 1P8 The cross slope of Me pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedeztnan Access Routes r opinion that roe 283%crass slope falls within .walk-Fndng829653 333383inding829653- a86 ADA Evaluation (PAR) East Sidewalk SSt Vradn Ave Slope•Cross NA NA NA 0037485 1055091 The cross slope of pedestrian access routes shall be 2 percent maximum 285%Open conventional constructiontolerance No arnon required. 2011 PROW.R3026 A35 $0 $01/1/2027-1/1/2033 Fin g_ 9]O60 890.Ipg Fndn'g_638089]0609a92031pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/0 inch and 1/2 inch that are not beveled tna n Access Router Vertical Surface Vertical surface dlsontmu es shall be 05 inch maximum V iced surface discontinuities between 023 inch he cen al surface dlsnunies to elinnate the East Sidewalk-Finding 830365• ae9 ADA Evaluation (PAR) East Sidewalk SSt grain Ave Surface Disconnulties NA NA 003I158 1055061 and 05 inch Wall be beveled wro a slope not steeper than 50 percent The bevel shall be applied across the 1 Open tnppinghazard 2011 PROW.R30272 A55 $75 $1301/1/2024-1/1/2027 Fin g_ 9681] _alpg The running slope of the right curb amp is excessive Pedeztnan Access Routes The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but Mall not p to provide a running slope gads less than 2011 PROWAG R30422 ewalk-Finding 89452530366 ,15821Finding830366- MO ADA Evaluation (PAR) East Sidewalk SSt Vrain Ave Curb Ramp Slope-Runnel(Grade) Paallel Ramp Right Ramp 4037204 1055066 require me ramp length to exceed 15,0ft 1055 p or equal rto c3%ra 2011 PROW.R30432 A2CR $3,000 $3,5001/1/2027-1/1/2033 Fin g_ 96899 _ Ttpg Fndmg_63808969008132]Slpg The Doss slope of Me pedestrian access route is excessive Ped Remove and West Sidewalk-Finding 829657• West Sidewalk•Finclmg 829.7- 493 ADA Evaluation (PAR) )stnan Access Routes West Sidewalk SSt Vrain Ave Slope•CroD NA NA NA 4037561 1055101 The cross slope of petlestnan access routes shall be 2 percent maximum 495%damaged concrete Open cross slope replace the misting y Mat has an excessive 2011 PROWAG P3026 A35 $1,500 $2,2501/1/2027-1/1/2033 30x5,150sq/N Fin g_ 089T149 _ 51pg 6lndlng_6330008850,58-688 1pg The Dots slope of the pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the muting walkway that has an excessive WestSidewalk-Finding 829658Sidewalk•Finding e29668- mo ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037511 1055096 The cross slope of petlestnan access routes shall be 2 percent maximum 330%Open Doss slope 2011 PROW.P3026 A35 $500 $76O 1/1/2027-1/1/2033 10a,osq/N Fnd1ng_6300897160207285.IPg dmg_655583738089T160895A08 6 The counter slope at Me gutter exceeds 5% n Access Routes The counter slope oft he gutter or street at Me Mot of curb ramp runs blended transitions and turning spaces a gutter/street s counter the ope does not West Sidewalk-Finding 8296.• West Sidewalk•Finclmg 829.9- 495 ADA Evaluation (PAR)) West Sidewalk SSt Vrain Ave Curb Ramp Slope at Gutter or Street NA NA 403751 1055.6 shall be 5 percent maximum 925%Open exceed 5%in the direction of the curb ramp run 2011 PROWAG P30454 A2CR $5,000 57,000 1/1/2027-1/1/2033 ern g_ 089T166 _ 01. 6lndlng_6330008868105-P0k 1pg The running slope of the curb amp is excessive Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curb amp shall be 5 percent minimum and 8.3 percent maximum but Mall not p to provide a running slope gads less than 2011 PROWAG P30422 stSidewalk-Finding 829662 530157indinge29662- Ms ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Slope-Runnmg(Grade) Ramp NA 4037482 1055092 require Me ramp length to exceed 1S.ON SD 55%Open or equal rto c3%ra 2011 PROW.R30432 A2CR $3,000 $3,5001/1/2027-1/1/2033 Fin g_ 9T18T _ e.IPg dmg_638089T18856D108Jpg There w no turning space at the tap of the curb amp If there is enough space provided to increase the length of the turning tall a turning space with the correct length ping space s minimum wide by4 in the direction of trael Mall be provided at (Refer "Finding.Mr dim ns)If there is not Me p a Me curb mpandshall be permitted to overlap oMerturnng spaces and dear spaces tall a turning space at Me top of the curb Finding 829663- 499 ADA Evaluation (PAR) Pedestrian Access Routes)) West Sidewalk SSt Vrain Ave Curb Ramp Turning Space Missing Perpendicular/Diagonal 4037468 1055092 06e0 amp,comet Memrsting Perpendicular curb ramp into a 2011 PROWAG P30421 A4CR 5500 51,0001/1/2027-1/1/2033 Fin g_ 089T196 _ 71. F ding_638089T19n2o258 ipg The running slope of the curb amp is excessive Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curb amp shall be 5 percent minimum and 8.3 percent maximum but Mall not Couldn't evaluate due to 2011 PROW.R304 2 2 WestSidewalk-Finding 829664. 500 ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Slope-Runnmg(Grade) Ramp NA 4037451 1055091 require me ramp length to exceed 15.0N snow Open 2011 PP0WAG R30432 A2CR TBD TBD 1/1/2027-1/1/2033 FindIng_638089720587547e.wg The Doss slope of Me curb ramp is greater than 2% Pedeztnan Access Router Wrth Yield or Stop Perpendicular or Dagonal curb p provide a cross slope gratle less than or Finding 829666- 502 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Curb Ramp Slope Cross Controls p 4037455 1055089 The cross slope of curb ramps blended tansibonz and turning spaces shall be 2 percent maximum 3T5%Open equal to 2%cur 2011 PROWAG 030453 A2CP 53,000 $3,5001/1/2027-1/1/2033 Fin g_ 089T218 _44.ipg F ding_638089T220201485jpg The cross slope of the curb amp is greater than 2%. The curb amp does have an excessive cross slope However,n is Pedeztnan Access Routes With Yield or Stop Perpendicular or Diagonal our minion that the crass slope of 2A96falls within conarnonal WestSidewalk-Finding 82966T West Sidewalk•Finding 82966T- NB ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Slope-Cross Controls Ramp 4037420 105.5058 The cross slope of curb ramps blended transitions and turning spaces shall be 2 percem maximum 240%Open construction tolerance No action required 2011 PP0WAG R30453 A2CR $ 5- 1/1/2027-1/1/2033 Finding_6380897226720649.IPg drrg_638089722750493 jpg The Doss slope of the pedestrian access route w excessive The pedestrian n Access Routes th s nthat e 26%cross slope falls withinstSidewalk-Fintling 829668 68 s slope Finding 504 ADA Evaluation (PAR)) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037411 1055088 The cross slope of petlestnan access routes shall be 2 percent maximum 260%Open conventionalcon1ruction tolerance No action required 2011 PROWAGR3026 A35 $0 $01/1/2027-1/1/2033 Fin g_ 089T231 _ ,PE 6,ntl,ng_6380898232184566jpg The cross slope of Its pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the muting walkway that has an excessrre WestSidewalk-Finding 829669Sidewalk•Finding e29669- so ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037402 1055086 The cross slope of pedestrian access routes shall be 2 percent madmen 82%at dmeway Open Doss slope 2011 PR0W.R302 6 A35 $1,500 $2,2501/1/2027-1/1/2033 301i5,150sq/N Fintling_6300897238239729.IPg dmg_653315738089T2388B3402 mg The detectable warning is missing at Me curb ramp Pedestnan Access Routes Curb ramps shall have a detectable Warning..extends Me full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends West Sidewalk-Finding 829670 506 ADA Evaluation (PAR)) West Sidewalk SSt Vrain Ave Curb Ramp Detectable Warnings Missing NA 4037366 1055083 sides 24 inch minimum m the direction of travel Both sides of driveway Open the full width of the curb ramp 2011 PROWAG P2081 ASCP $700 50001/1/2027-1/1/2033 Finding_6380897244860_778.1196 The cross slope of the pedestrian access route Is excessive Pedeztnan Access ROtnes RerTIOVe and replace the wasting walkway that has an excessrre West8,,038Sidewalk-Finding8296T1 walk•Finding 829671- stSidewalk-Finding 8296T] 554157indinge296T1- SW ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037366 105.5082 The cross slope of petlestnan access routes Mall be 2 percent madmen 4696i.35% Open Doss slope 2011 PR0W.R3026 A35 56,400 $9,6001/1/2027-1/1/2033 80xe,64osq/N Finding_630089T250465_401.4 dmg_638089T251358341 cog Fnding_630o89T252215261.4 dmg_638089T25418]Maxes The Doss slope of the pedestrian access route w excessive Pedeztnan Access Routes Remove and replace the existing walkway that has an excessive WestSidewalk-Finding 829672Sidewalk•inding8296T2- SDP ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope routes Cross NA NA NA 403T34 1055081 The cross slope of petlestnan access shall be 2 percent maximum 915%at driveway Open cross slope 2011 PROWAG 03026 A35 52,400 $3,600 1/1/2027-1/1/2033 30xe,240sq/N Fin g_ 089T260 _ 21Pg Fin 55 g_ 0337 089T26 _ 1pg The detectable warning is missing at the curb ramp Pedeztnan Access Rwttes Curb ramps Mall have a detectable wammg that extends the full widm of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that ertendx West Sidewalk-Fintling 829673• 509 ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Ramp Detectable Wamrngs Missing NA 4037337 1055081 sides 24 inch minimum m the direction of travel Both sides of driveway Open the Pull widen of the curb ramp 2011 PR0W.52081 ASCR $700 Sew 1/1/2027-1/1/2033 FindIng_6380897364806_274.4 The Doss slope of the pedestrian access route is excessive Pedeztnan Access Router Remove and replace Me existing walkway that has an excessive WestSidewalk-Finding 8296]4 West Sidewalk•Finding 8296T4- 530 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037343 105508 The cross slope of petlestnan access routes shall be 2 percent maximum 445%Open cross slope 2011 PROWAG 03026 A35 54,000 $6,000 1/1/2027-1/1/2033 50xe,400m/N Fin g_ 089T269 _ T.IPg F dmg_638089T2T04036TOjpg The cross slope of the curb ramp is greater than 2%. The curb amp does have an excessive cross slope However,n is Pedeztnan Access Rwttes With Yield or Stop Perpendicular or Diagonal our opinion that the cross slope of 26%falls wrtnnnnarmonal West Sidewalk-Finding 829675 West Sidewalk•Finding 8296T5- 511 ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Slope-Cross Controls Ramp 4037325 105 SOB The crass slope of curb ramps blended tansitions and turning spaces shall be 2 percent maximum 111.11 260%Open construction tolerance No action required 2011 PR0W.R30453 A2CR $ 5- 1/1/2027-1/1/2033 Finding_6300897277357275.IPg dmg_6380897278223367Ipg The surface of Me pedestrian acre3S route has pe g greater than In inch Pedeztnan Access Routes openings gratings Joints Mall not permit passage of a sphere more than l3 mm(05 nil in stSidewalk-Finding 8296T6. 512 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Surface Horizontal Openings Greater Than l/21nch NA 4037323 1055079 diameter cup Open Repair the walkway to eliminate openings tl tripping hazard 2011 PROWAG R302 T 3 A55 $100 Mar 1/1/2024-1/1/2027 Fin g_ 089T20o _ 61. The cross slope of the curb ramp is greater than 2%. Pedeztnan Access Rwttes With Yield or Stop Perpendicular or Diagonal br p to provide a cross slope grade less than or stSidewalk-Finding 8296TT walk•Finding 8296TT- 513 ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Slope-Cross Controls Ramp 4037294 1055076 The cross slope of curb ramps blended tansitions and taming spaces shall be 2 percent maximum 435%Open equal to 2%cur 2011 PR0W.R30453 A2CR $3,000 $3,5001/1/2027-1/1/2033 Fnding_6300897208832_006.4 dmg_638089728938380mg The Dots slope of the pedestrian access route is excessive Pedeztnan Access Routes Remove and replace Me existing walkway that has an excessive WestSidewalk-Finding 8296Te Finding 8296Te- WestSidewalk-Finding 829678Sidewalk•Finding 8296T8- 514 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037299 •105577 The cross slope of petlestnan access routes shall be 2 percent maximum 4696-34% Open cross slope 2011 PROWAG 03026 A35 57,200 110,800 1/1/2027-1/1/2033 90xe,720sq/N Fin g_ _089T292 T1pg Fn g_ 089T293 _ 1pg Fin g_ 089T29T _ 2IP, F ding_653080738089T29854362 MP There Is no turning space at the tap of the curb ramp If there is enough space provided to increase the length of the turning spaceinstall correct length arming space.inches minimum wide by 48 inches minimum in the direction of ravel Mall be provided at (Refer to Column N"Findingr"for dimensions)If there is next Pedeztnan Access Rwttes the top of Me curb ramp and shall be permitted to ovedap mMr turning spaces and clear spaces 696curb ramp..no enough space to Install a turning space at the top of the curb WestSidewalk-Finding 8296T9 West sidewalk•Finding e296T9- MS ADA Evaluamn (PAP) West Sidewalk SSt Vrain Ave Curb Pamp Taming Space Missing Perpendicular/Diagonal 4037270 1055074 landing Open ramp,convert the eximng perpendicular curb ramp Into a 2011 PR0WAGR30421 AO-CR $500 $1,0001/1/2027-1/1/2033 Fnding_6300897305022604mg dirg_6380897305921746 mg The counter slope att gutter exceeds 5% Pedeztna nAccess Routes w r The r slope of the gutter or street at the foot of curb r p runs blended transitions and turning spaces Remade the gutter/street s t the counter a does not rslop Sidewalk-F Finding 829680- 516 ADA Evaluation (PAR) West Sidewalk SSt Vrain Ave Curb Ramp Slope at Gutter or Street NA NA 4037262 1055074 shall be 5 percent maximum T%Open exceed 5%in Me direction of the curb ramp run 2011 PROWAG 030454 A2CP $5,000 57,0001/1/2027-1/1/2033 Fin g_ 089T313 830 mg Fincling_6380897314019_74,M8 I The Dots slope of the pedestrian access route is excessive Pedeztnan Access RwBez Remove and replace the wasting walkway that has an excessive West Sidewalk-Finning 829681 West Sidewalk•Ending 029681- stSidewalk-Fintling 829681 West sidewalk•Fnding029681- 51T ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037262 1055074 The crass slope of petlestnan access routes shall be 2 percent madmen 96-T.6% Open Doss slope 2011 PR0W.R302 6 A35 512,000 $18,0001/1/2027-1/1/2033 150,8%1,200sq/N F ding_630oe9T32138T41 cog dirg_6380897322216787 mg Fin g_ 9T33 _ e.4 dmg_6380897330950241 mg The surface of Me pedestrian access route has openings greater than 1/2in. n Access Routes openings in gratings and Joints shall not permit passage of a sphere more man 13 min(05 ill In West Sidewalk-Finding 829682• 518 ADA Evaluation (PAR) West West Sidewalk SSt Vrain Ave surface Horizontal Openings Greater Than 1/21nch NA 4037217 10S SOT diameteral op open Repair the walkway to eliminate openings and tripping hazard 2011 PROWAG R302 T 3 Ass $300 54o01/1/2024-1/1/202T Fir g_ 089T352 _ Joe . The Dots slope of the pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the wasting walkway that has an excessive WestSidewalk-Finding829683 West Sidewalk•Finding 829683- 519 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 40 3721 1055069 The crass slope of petlestnan access routes shall be 2 percent madmen 530%Open Doss slope 2011 PR0W.R302 6 A35 $4,800 $7,2001/1/2027-1/1/2033 601i8,480sq/N Fnd1ng_6380897355245_183.4 dirg_63808973559319281p6 The Dots slope of the curb ramp is greater than 2% Pedeztnan Access Routes WMVield or Stop Perpendicular or Diagonal Reconstruct Curb r p to provide a cross slope grade less than or WestSidewalk-Finding 829684 West Finding 829684- 520 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Curb Ramp Slope Cross Controls Ramp 4037184 •1055067 The cross slope of curb ramps blended transitions and taming spaces Mall be 2 percent maximum 530%Open equal to 2% 2011 PROWAG R30453 A2CR $3,000 53,5001/1/2027-1/1/2033 Fin g_ 089T3T0 _ 21Pg F dmg_6550807380897371148801 ill . The Dots slope of the pedestrian access route is excessive Pedeztnan Access RwBez Remote and replace the wasting walkway mat has an excessive WestSidewalk-Finding 829685 West sidewalk•Finding 829685- 521 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037186 1055067 The crass slope of petlestnan access routes shall be 2 percent madmen 655%Open Doss slope 2011 PR0W.R302 6 A35 $1,600 PA001/1/202T-1/1/2033 20xe,160sq/N Fnding_6380897375925708.4 dmg_638089737738677elpg The cross slope of Me pedestrian access route is excessive The pedestrianslope Pedez nAccess Routes opinion that s slopechlls within Sidewalk-F Finding 829686- 522 ADA Evaluation (PAR) West West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037355 1055065 The Doss slope of petlestnan access routes shall be 2 percent maximum 235%Open conventional constructiontolerance 3No arnon required 2011 PROM.03026 A35 SO 50 1/1/2027-1/1/2033 Fin g_ 089T383 _ 08pg 6.616,63300086.6,06-P.l6P ■ 1 The Dots slope of the pedestrian access route is excessive Pedeztnan Accezz RwttezRemove and replace the wasting walkway that has an excessive WestSidewalk-Finding 82968TSidewalk•Finding e2968T- 523 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 4037157 1055064 The crass slope of petlestnan access routes shall be 2 percent madmen 696at driveway Open Doss slope 2011 PP0WAG R302 6 A35 Szaoo $3,600 1/1/2027-1/1/2033 30xe,240sq/N Fin g_ 9T39 _ 3.4 dmg_655415738089T391115251 mg The detectable warning is missing at the curb ramp Pedeztnan Access Roirtes Curb ramps shall have a detectable vnmmg that extends the full width of the curb ramp excluding the flared Throe an...compliant detectable warning surface that extends West Sidewalk-Finding 339688. ADA Evaluation (PAP) rtSidewalk Curb Pamp Detectable Warnings Missing NA 403I153 1055065 sides 34 inch minimum in the direction of travel IoM sides of driveway p the full width of the curb ramp 011 PROWAG R3081 ASCP $700 50001/1/3037-1/1/3033 Fin g_ 089]404 _ 11Dg ' _ 2 The cross slope of the pedestrian access route is excessive Pedeman Aaesz Rau[ez antl replacetheewzting walkwaymat M1aa anexrezzrreWestSidewalk-Finding 339690 walk•Finding 8296W- 535 ADA Evaluation (PAP) West Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 40 3713 1055063 The crass slope of pedestrian access routes shall be 2 percent madman 330%Open cross slope 3011 PROW.R303 6 A35 $2p00 $3,6001/1/2037-1/1/3033 30a,MOWN Fin g_ 9]4 _ e.ro dmg_638089]444618239). The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excess). WestSidewalk-Fintling 339691 Finding 839691- 536 ADA Evaluation (PAP) WestSidewalk S St Vraln Ave Slope•Cross NA NA NA 403I133 1055W3 The crass slope of cedetnan access routes shall be 3 percent maximum wsszlope3011 PROW.R xe 3036 A35 82,400 53,6001/1/3037-1/1/3033 30 ,340zq/N Fin g_ 56 089]4 _ mg_ ]IPg d633089I45]]]35311es 1.1 _ The cross slope of the curb ramp is greater than 3%. Pedeztnan Access Routes WBM1 yield or Stop Perpendicular or Dagonal ReCOnStIliCt curb ramp to provide a cross slope grade less than or stSidewalk-Finding 829693 t5idewalk•Finding e29692- 537 ADA Evluenon (PAP) West Sidewalk SSt Vrain Ave Curb Pam, Slope-Cross Controls p 403I0]] 105.5057 The cross slope of curb ramps blended tnwtions and taming spaces Mall be 2 percen maximum 380%Open equal to 3% 3011 PROW.R30453 A3CR $3,000 $3,SW 1/1/3037-1/1/3033 Findng_6300897466099_328.Ipg dmg_638089]466830699). Therms no turning space at the top of Me curb romp If mere is enough space prowtled to increase the length of the ace wro the correct ping Space.inches minimum wide by.inches minimum in Me direction of travel shall be provided at (Refer turning Column Nl"Finding.for dimensions)If mere length not Pedez nAccess Routes that p of the curb ramp and Mall be permitted to overlap other turning space and clear spaces running slope curb enough space installa tMe top oftM1 curb Sidewalk-F walk•Finding 839693- 538 ADA Evaluation (PAR) West Wert Sidewalk SSt Vrain Ave Curb Pamp Turning Space Missing Perpendicular/Diagonal 5055 r p planding p romp,convert the...mguPerpenticular curb ramp into a 3011 PROW.R30431 A4CP $500 51,0001/1/3037-1/1/3033 Fin g_ 089]4]] _ 591Pg dmg_638089747845]834 jpg M10 The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedeztnan Access RaBez However,it s our opinion that the 34%cross slope falls within stSidewalk-Finding 829694 t5idewalk•Finding e29694- 539 ADA Evluenon (PAP) Wert Sidewalk SSt Vrain Ave Slope•Cross NA NA NA 40 3705 1055054 The cross slope of pedestrian access routes shall be 2 percent madman 240%Open conanionalconrtrection tolerance No action required 3011 PROW.R3036 A35 $0 $0 1/1/3037-1/1/3033 Fnding_6380e97404336493.IPg ding_638089]485225523). The s slope of Me pedestrian Pedestn nAccesx Routes Remove and Wert Sidewalk SSt Vrain Ave Slope•Cross NA NA Na4037041 los 5054 The cross slope of pedestrian access access `place the existing y thasanexcesxry routes percent 5% West Sidewalk-Finding 329695• West Sidewalk•Finding 839695- tes shall be 2peent maximum 55 at driveway Open Thou slope 530 ADA Evaluation (PAR) 3011 PROWAG R3036 A35 50 50 1/1/2037-1/1/3033 Finding_63008974909I9_90leg fin g_ 089I491 _ Ipg The detectable warning is missing at the curb ramp Pedestrian Access Ruutez Curb ramps shall have a detectable wammg that extends the full widen of me curb ramp excluding the flared Inroll an ADA compliant detectable warning surface that extends West Sidewalk-Finding 339696 531 ADA Evaluation (PAP) S Ave Curb Ramp Detectable Warnings Missing NA 403I014 105503 Wes 34 inch minimum in the direction of travel Bath sides of driveway Open the full width of me curb ramp 3011 PROWAGP2081 ASCR 5700 $8001/1/2027-1/1/2033 FindIng_6380e97494I01591pg rampsThe cross slope of Me turning space exceeds.rnaximurn The cross slope of curb Pedessnan Access Routes WM Yield or Stop pedestrian streetitlblock pedestrian street crossings Me cross Regrade Me turning space of the curb ramp,so that the cross West Sidewalk-Finding 329698. West Sidewalk•Finding 839693- 533 ADA Evaluation (PAR)) Wert Sidewalk SSt Vrain Ave Curb Pamp Turning Space Slope 9Cmss Controls 4036.9 •1055051 slope shall be permitted to equal the street or highway grade 555%Open slope does not exceed 3% 2011 PROWAG R30053 A4CP 51,000 $1,5001/1/2037-1/1/3033 Froing_6300897506I65_560mg Fin g_ 089I50] _ Ipg The running slope of Me right curb ramp is excessive The curb amp does have an excessive running slope However, Pedessnan Access Routes The running slope of the curb amp shall be 5 percent minimum and 8.3 percent maximum but Mall not r opinion that the running slope of9%falls within Couldn't evaluate rest of curb WestSidewalk-Finding 339699 West sidewalk•Finding 839699- 534 ADA Evluenon (PAP)) West Sidewalk SSt Vrain Ave Curb Ramp Slope-Rumeng(Rade) Parallel Pamp Right Ramp 403I109 1055059 require the ramp length to exceed 15.ON 996Open conventional construction tolerance No action required 3011 PROW.R30432 A2CR $ $- 1/1/2027-1/1/2033 amp due to snow Fin g_ 9]518 _ 1.IPg dmg_6380897519587e79 jets The cross slope of the curb ramp is greater than 2% Pedessnan Access Routes or Stop Perpendicular or DiagonalReconstruct curbat p to provide a cross slope grade less than or West Sidewalk-Finding 829701• West Sidewalk•Finding 839701- 536 ADA Evaluation (PAR)) West Sidewalk SSt Vrain Ave Curb Pamp Slope Cross Controls Ramp 4037008 4055059 The cross slope of curb ramps blended transin0.and turning spaces shall be 2 percent maximum 865%Open equal to 3% 2011 PROWAG R30453 ASCP $3,000 53,500 1/1/2027-1/1/2033 Pin g_ 089]53386310Ipg Findmg_6380897533655_931pg The cross slope of the curb ramp is greater than 2%. Pedestrian Access Routes Wrth yield or Stop Perpendicular or Diagonal bat p to provide a cross slope grade less than or stSidewalk-Finding 339]03 walk•Finding 839]02- 53] ADA Evluenon (PAP) West Sidewalk SSt Vrain Ave Curb Ramp Slope-Cross Controls ampnd 4036923 105.5045 The cross slope of curb ramps blended tarwtions and taming spaces Mall be 2 percent maximum 485%Open equal to 3%cur 3011 PROW.R30453 A3CR $3,O00 $35001/1/3037-1/1/3033 Fintling_6380e9]541372_5]3zps dmg_6380897543045193Ipg The 3ronches minimum 1.48 i minimum clear floor space required at the pushbutton is consistent with t grade of the admcen pedertan access route Accessible Pedestrian g rain/Big Thompson Slope-Parallel to the Changes in levelrmeted at q th required clear floor or ground space except at slopes not steeper than Remade concrete at the accessible pedestrian signalso that the 500 ADA Evaluation (APS) Intersection Ave Clear Floor Space Pedestrian Access Route NA NA 403I807 105 5165 1 48 shall be permitted 5%at push button Open running and cross slope do not exceed 2% 2011 PROW.R404 2 A35 $1,000 $1,5001/1/2037-1/1/3033 Fin g_ O9o]3]]36>_545 mg F1nd118_6380$0I27e _ Ipg The cross slope of the curb ramp is greater than 3%. Peden nAccess Routes in/Big Thompson WBM1 yield or top Perpendicular or Diagon bat p to provide a cross slope grade less than Finding33000g Finding 830048- 544 ADA Evaluation (PAR) Intersection Intersection Ave Curb Ramp Slope-Cross Controls amp 403]]86 1W SS]The cross slope of curb ramps blended tansltions and turning spaces Mall be 2 percent maximum 435%Open equal to 3%cur 3011 PROW.R30453 A2CR $3,000 $3,5001/1/3037-1/1/3033 Fndng_638090]31308]400zps Fndmg_6380907315159916 roe The 3ronches minimum 1.48 inches minimum clear floor space required at the pushbutton is consistent with Me grade of the adpcen pedestrian access route Accessible Pedestrian g rain/Big Thompson Slope-Parallel to the Changes in levelrmetetl at q th required clear floor or ground space except at slopes not steeper Man Regncle concrete at Me accessible pedestrian signalso that the 505 ADA Evaluation (APS) Intersection Ave Clear Floor Space Pedestrian Access Route NA NA 403I803 .105 5173 1 48 shall be permitted 93%at push button Open running 2%d cross slope do not exceed 2011 PROWAG R000 2 A35 $1,000 $1,5001/1/2037-1/1/3033 Fin g_ Wo]319 _ 1leg Fin g_ 32 090I0 _ Ipg The 30 inches minimum 48 inches minimum floe p required at me pushbutton is consistent with the grade of the adpcen pedestrian access route Accessible Pedeztnan Signal St Vram/Big Thompson Slope-Parallel to the Changes in level are not permitted at required clear floor or ground space except that slopes not steeper than Regade concrete at the accessible pedestrian signal so that theFinding 830051 Finding 830051- 547 ADA Evaluenon (APS) Intersection Ave Clear Floor Space Pedestrian Access Route NA NA 403I007 10551 49 Mall be permitted 5%Open running and cross slope do not exceed 2% 3011 PR0WAG R4043 A35 $1,O00 $1,5001/1/3037-1/1/3033 Findng_6380907345346_]]Ipg Fmdmg_638090]34603]]541pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch antl 1/2 inch that are not beveled n Access Routes rain/Big Thompsonsurfacesh all all be 05 inch maximum V ial surface discontinuities between 025 inch th vertical surface discontinuities to eliminate e 508 ADA Evaluation (PAP)) Intersection Ave Surface Discontinuities NA NA 003I823 3055169 and 05 inch shall5111 be beveled with a slope not steeper than 50 percent The bevel shall be applied across Me 3 Open pp g hazard 2011 PROWAG R3027 2 A55 $75 5150 1/1/2024-1/1/2027 Finding_6380907351243_833.ro The surface of the pedestrian access route has openings greater than 1/3 inch Pedeztnan Access Routes m T1 al openings in gratings and mints shall not permit passage of a sphere more than 13 m(0S in) Sidewalks-Fmding839 ]- di Finng839]]]- 551 ADA Evluenon (PAP) Sidewalks 6EIkhom Ave Surface Horizontal Openings Greater Than 1/31nch NA 40 3]]3 105.5175 diameter 4'at drain Open Repair me walkway to eliminate openings and topping hazard 3011 PROW.0.3027 3 A55 $300 $5001/1/3034-1/1/3037 Finding_638090544]303]61.I,g Findmg_63809054481462361pg n Access Routes The cross slope of Me pedestrian access route is excessivePedestna replaceRemove and the existing walkway Mathas an excessive Sidewalks•Finding 839]]9 553 ADA Evaluation (PAR)) Sidewalks E Elkhorn Ave Slope•Cross NA NA NA 4037744 105517e Mall cross slope of pedestrian access routes all be 3 percent maximum 3 45%33% Open cross slope 2011 PROWAG R302 6 A35 54,500 $6,I501/1/2027-1/1/2033 05x10,450sq/ft Fin g_ 0305463 _ 3.IDg Fin g_ 05 09463 _ Ipg The surface of the pedestrian access route has vertical discontinuities greater than 1/3 inch or between 1/4 Inch and 1/2 inch that are not heeled Pedestrian Route Venice Surface surface disco shall be al surface discontinuities between rind down the vertical surface discontinuities to eliminate the Sidewalks-Finding829]81- MO ADA Evaluation WAR) Sidewalks Sidewalks 6EIkhom Ave Surface Discontmelhes NA NA 403]]53 SW S18 and 05 inch shall be beveled valet a slope not steeper50 percent The bevel shall be applied across Me 19 Open nipping hazard 3011 PROW.R3037 2 A55 $75 $150 1/1/3034-1/1/3037 Finding_6380905480I03853zpg n Access Routes The cross slope of Me pedestrian access route is excessivePede replaceRemove and e existing y Mat has an excessive Sidewalks•Finding 839783 • Sidewalks•Finding 556 ADA Cross NA NA NA 403773] 1055133 The slope of petlestrian access routes shall be 3 percent maximum 560%Open cross slope 3011 PROWAG R303 6 A35 52,600 $3,900 1/1/2027-1/1/2033 26x10,260sq/ft Fin g_ 0305494 _ 1.IDg Fntlm 05 g_6330940S1390 Evaluation (PAR)) Sidewalks EElkharn Ave Slope th 135 ill The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope PedeztnanAccess Routes opini n that h our... 3516 cross slope 0lls within Sidewalks-Finding8E9]84- di Finng 557 ADA Evaluation (PAP) Sidewalks 6EIkhom Ave Slope•Cross NA NA NA 403]]33 105 SIM The cross slope of pedestrian access routes shall be 2 percent madman 235%Open conanionalconrtrua on tolerance No action required 3011 PROW.R303 6 A35 $0 $0 1/1/3037-1/1/3033 FindIng_6380905505980_569.IPg Findmg_638090550661086921pg The detectable warning is missing at the curb ramp n Access Routes have detectable warning that extend..full width of the curb ramp excluding the flared cable warning surface that extends Sidewalks•Finding 829785• 558 ADA Evaluation (PAP)) Sidewalks EElkharn Ave Curb Pamp Detectable Warnings Missing NA 003]]24 3055185 side 34 inch maiinrmumam the direction of travel Open the full width of Mel curb rmept 2011 PROWAG R2081 ASCP $350 $400 1/1/2027-1/1/3033 Finding_6380905515780_6471pg The cross slope of the pedestrian access route II excessive Pedestrian Access Routes Remove and replace the westing walkway that has an excessive Sidewalks-Finding e29]e]- Findinge39]8]- 560 ...legion (PAP) Sidewalks 6EIkhom Ave Slope-Cross NA NA NA 403]]21 105.5184 The crass slope of pedestrian access routes shall be 3 percent maximum ]95%Open cross slope 3011 PROW.R303 6 A35 $2A00 $3,600 1/1/3037-1/1/3033 30118,MOWN Finding_6380905525584_450.IPg Findmg_63809055264344481pg The detectable warning is missing at the curb ramp n Access Routes have detectable warning that extends the full width of the curb ramp excluding the flared detectable warning mace that extends Sidewalks•Finding 829788• 561 ADA Evaluation (PAP)) Sidewalks EElkharn Ave Curb Ramp Detectable Warnings Missing NA 003]]22 3055188 side 34 inch maiinrmumam the direction of travel Bath sides of driveway Open the full wdthof Mee curb ramp 2011 2011 PROWAG R2081 ASCP 5100 $BW 1/1/2027-1/1/3033 Finding_6380905531013_55 Ipg The running slope of the curb ramp is excessive Pedeztnan Access Roirtez Perpendicular or Diagonal curb amp shall be 5 percent minimum and 8.3 percent minmum 19.Mall not p to provide a running slope gads less man 3011 PROWAG R30422 Sidewalks-Finding 839790- Finding839790. 563 ADA Evluenon (PAP) Sidewalks 6EIkhom Ave Curb Ramp Slope-Rumeng(Rade) Pamp NA 403]]36 10551 re the ramp length to exceed 15.0 N SD 55%0pen or equal rto c3%ra 3011 PROW.1130432 A3CR $3,O00 $3,5001/1/3037-1/1/3033 Finding_6380905557322173rog Findmg_63809055603I99631pg Re running slope ofMe turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb ramp shall cut through or Mall be built up to the curb at right angles or shall n Access Routes r The running slope of the curb ramp space of the curb ramp,so that the running Sidewalks•Finding 839791 564 ADA Evaluation (PAP)) Sidewalks 6Elkhorn Ave Curb Pamp Turning pace Slope Running Perpendicular Ramp 403I698 1055194 shall be 5 percent minimum and 83 percent maximum but shall of require the ramp length to exceed 1SN 415%Open slope does not exceed 3% 3011 PROW.R30422 AS-CR $1,000 $ySW 1/1/2027-1/1/3033 Fin g_ 0905565 _ 0mg 11nd1ne_6330905.7153_3 Ipg The cross slope of the pedestrian access route is excessive Pedeztnan Access Roirtez Remove and replace the westing walkway that has an excessive Sidewalks-Finding 839]93- Finding839793• 565 ADA Evaluation (PAP) Sidewalks 6EIkhom Ave Slope-Cross NA NA NA 403I699 1055195 The cross slope of petlestrian access routes shall be 3 percent maximum 6 Oro Open cross slope 3011 PROW.R303 6 A35 $2A00 $3,6001/1/2037-1/1/3033 30118,MOWN FindIng_6380905570619454gpg Findmg_6380905573843202,mg The turning space at the nip of the ramp is not the correct length tna n Access Routes endm r ular/Diagonal-Length in the Direction of erne turning space is constrained at the back.of-sidewalk theturmng space shall be 48 Inches minimum m Provide a turning space that is 48"by6o and does not exceed a Sidewalks-Finding829]93- 5W ADA Evaluation (PAR) Sidewalks 6EIk1om Ave Curb Ramp Turning Space Constrained Ramp Run 0037703 1055195 rodeby601nc/es minimum in the direct,on of the ramp run 36 Open 3%slope in amidention 3011 PR0WAG R30431 AO-CR WO $750 1/1/3037-1/1/3033 Fintling_6300905500024_607 jpg Findmg_6380905580813_1041pg The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding 829]95- Finding829I95. Sidewalks-Finding 829]95- Finding829I95. sse ADA Evaluation (PAR) Sidewalks 6Elkham Ave Slope.Cross NA NA NA 4037I3 1055188 The cross slope of pedeMan access routes shall bet percent maximum 596 Opencross slope 2011 PR0W.R3026 A35 $4,000 $7,200 1/1/202I-1/1/2033 60x0,480sq/h Fm g_ 05595 _ 84pg Findng_636090559612058 jpg Fm g_ 0559I _ 34pg Findng_63609055907103101pg III cross slope of the pedestrian access route is excessive Ped Remove and Sidewalks•Finding 829797• Sidewalks•Finding 829797. 5I0 ADA Evaluation (PAR) )stnan Access Routes Sidewalks EElkham Ave Slope•Cross NA NA NA 403I693 10552 The cross slope of petlestnan access routes shall bet percent maximum 6]0%Open cross slope replace the existing walkway that has an excessry 2011 PR0WAG R302 6 A35 52,400 $3,6001/1/202I-1/1/2033 30x0,240sg/ft Fin g_ 0905622 _ 11p6 Finding_6380905623638_397 Ipg The detectable warning is missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 829]98- 5]1 ADA Evaluation (PAR) Sidewalks EElkham Ave Curb Ramp Detectable Warnings Missing NA 403I702 105 5191 sides 20 inchmmnum in the direction of travel Both sides of driveway Open the full width of the curb ramp 2011 PR0WAG R2081 ASCR $700 5800 1/1/202I-1/1/2033 Finding_63809056261579I1.0g lbe surface of the pedestrian access route has vertical discontinuities greater.an 1/2 inch or between 1/4 inch antl 1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface VeMcal surface discontinuities shall be 05 inch maximum Vertical surface discontinuities between 025 inch Grind clown the vertical surface discontinuities to eliminate the Sidewalks•Finding 829800• 573 ADA Evaluation (PAR)) Sidewalks EElkhorn Ave Surface Discontinuities NA NA 403I684 •1055199 and 05 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across Me 1 OPPOIIPPIPSNSPAOA 2011 PR0WAG R3027 2 A55 $IS $1201/1/2024-1/1/2027 Finding_6380902639191_391.1pg The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratings and joints shall not permpermitai passage of a sphere more than 13 m(05 in)in Sidewalks-Fmtlmg 829801- 570 ADA Evaluation (PAR) Sidewalks EElkhorn Ave Surface Horizontal Openings Greater Than l/2Inch NA 403I6I5 105.5199 diameter Open Repair the walkway to eliminate Openings and tripping hazard 2011 PR0W.R3027 3 A55 $100 $150 1/1/2024-1/1/2027 Finding_6380905603I39311.Ipg The cross slope of the pedestrian access route is excessive replaceRemove and the existing walkway that has an excessive Sidewalks-Fmmg tl 829803 576 ADA Evaluation (PARPedestrian Access Routes)) Sidewalks EElkhorn Ave Slope•Cross NA NA NA 003I685 1055201 The cross slope of pedestrian access routes shall be 2 percent maximum 6 10%Open cross slope 2011 PR0WAG R302 6 A35 $1,600 $2,400 1/02027-1/1/2033 2003,160w/ft Fm g_ 0905658 _ 21. Fntln6_6380905650696o4000g The detectable warning a missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 829804- 5]] ADA Evaluation (PAR) Sidewalks 6Elkham Ave Curb Ramp Detectable Warnings Missing NA 003I685 1055203 sides 24 inch minimum in the direction of ewe! Bath sides of driveway Open the full width of Me curb ramp 2011 PR0W.R2081 ASCR $700 58001/1/2027-1/1/2033 Finding_638090566SSIN33]1_N690pg The cross slope of the pedestrian access route is excessive n Access Routes and replace the existing walkway that has an excessive Sidewalks-Finding 829806 Sidewalks-Finding 829806 578 ADA Evaluation (PAR)) Sidewalks EElkham Ave Slope•Cross NA NA NA 003I685 10552 cross slope of petlestnan access routes shall bet percent maximum 635%375% Open cuss slope 2011 PR0WAG R3026 A35 $11,500 $1I,2501/1/2027-1/1/2033 115x10,1,10sq/ft Fin g_ 0905666 _ 11p6 Findng_636090566I089a609 jpg Fm g_ 0905669 _ 1wg Fin g_ 0905628 _ 168 03 The required additional maneuvering space is not provided fora parallel approach Where a clear space is confined on all or part of three sides additional maneuvering space shall be provided Pedestrian Access Routes Confined Greater than 15 Remove section of curb at the push button to provide the 2011 PROW.RON 7 Sidewalks-Finding 829811- sidewalks-Rndmg629811- S83 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Clear Floor Space Parallel Approach Inches Maneuvering Space 403]6] 105 S213 The clear space arrd atldmonal maneuvering space shall.5Oft wide minimum where the depth exceeds 1537 Open required maneuvering clearance 2011 PR0W.R0007 2 A3S $250 MO 1/1/2027-1/1/2033 Fmding_6380905I51805_625,pg Fndng_6360905753174147 Ipg The cross slope of the pedestrian access route exceeds 296 The pedestrian n Access Routes Pedestrian n that the 2 75%crass slope cfalls within Sidewalks-Fmtlmg 829812 Sidewalks•Finding- 500 ADA Evaluation (PAR)) pe Sidewalks EElkhorn Ave Refuge Islands Slope Cross Yield or Stop Controls NA 403I65I 1055214 The cross slope of petlestnan access routes shall bet percent maximum 2]0%Open conventional constructiontolerance No action required 2011 PR0WAG R3026 A35 Al AO 1/02027-1/1/2033 Fm g_ 0905I61 _ 2.06 Findng_6360905]6 2 5101 2 01jpg The running slope of the curb ramp is excessive The curb ramp doe have an excessive running slope However, Pedestrian Access Routes Perpendicular or Diagonal Re running slope of the curb ramp shall be 5 percent minimum and 8,3 percent maximum but shall not Is our opinion Mat the running slope of 9206fazwithin 2011 PROW.R300 2 2 Sidewalks- N829814- walks-Finding 829810- 586 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Curb Ramp Slope-Runneig(Grade) Ramp NA 003I661 1055215 require Me ramp length to exceed 1S.OR 9Mt Open conventional construction tolerance Na action required. 2011 PR0W.R30032 A2CR 5- 5- 1/1/202I-1/1/2033 Finding_638AS090A75]]6298164.IPg Fndmg_6380905777330976 jpg Re running slope of Me turning space at the top of the curb ramp exceeds 2%maximum The running slope of the curb nrnp shall cut through or shall be built up to the curb at right angles or shall n Access Routes r re The running slope of the curb ramp space of the curb ramp,so that the running Sidewalks-Finding 829815 507 ADA Evaluation (PAR)) Sidewalks EElkhorn Ave Curb Ramp Turning pace Slope Running Perpendicular Ramp 403I656 1055215 shall be 5 percent minimum antl 63 percent maximum but shall not require the ramp length to exceed 15ft 300%Open slope does not exceed 2% 2011 PR0WAG R30422 A4CR $1,000 0,500 1/02027-1/1/2033 Fm g_ 0905I82 _ 11p6 Findn6_63809052832661232 jpg The detectable warning is missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable warning that extends the full width of Me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 829816- 580 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Curb Ramp Detectable Warnings Missing NA 003I654 105521I sides 20 inch mmnum m the direction of travel Open the full width of the curb ramp 2011 PR0W.R2081 AS-CR $350 $4001/1/2027-1/1/2033 Finding_6380905I0623635jpg The running slope of the curb ramp rs excessive The curb ramp does e an ring slopHowever, n Access Router icular or Dagonal The running slope of the curbramp shall be 5 percent minimum antl 83 percent maximum but shall not r opinion Mat the ru ning slope ofne9%fallswth Sidewalks-Finding82981I Sidewalks•Finding- 509 ADA Evaluation (PAR)) Sidewalks EElkhorn Ave Curb Ramp Slope Run mg(Grade) Ramp NA 403I656 10552 re the ramp length to exceed 150 ft 8SO%Open conventional construction tolerance No action required 2011 PR0WAG R30432 A2CR S 5 1/1/202I-1/1/2033 Pm g_ 0905I89 _ 31p6 Findng_6360905]899I0164]jpg 16 Re cross slope of the turning space exceeds 2%maximum The crass slope of curb ramps blended transitions and turning spaces shall be 2 percent maximum At Pedestrian Access Routes With Yield or Stop pedestrian street crossings without yield or stop control and at mitlblock petlestnan street crossings the cross Regnde the turning space of the curb ramp,so that Me cross Sidewalks-Finding 829818- walks-Finding - SOO ADA Evaluation (PAR) Sidewalks 6Elkham Ave Curb Ramp Turning Space Slope-Cross Controls 003I656 105.5217 slope shall be penned to equal the street or highway grade 390%Open slope does not exceed 2% 2011 PR0W.R30053 AO-CR $1,000 $1500 1/1/2027-1/1/2033 Finding_6380905I9583621Swg Fnding_6360905]9SNSS6925_S]2 jpg The detectable warning is missing at the curb ramp Pedestnan Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Fmtlmg 829819- 591 ADA Evaluation (PAR)) Sidewalks EElkhorn Ave Curb Ramp Detectable Warnings Missing NA 403I661 1055216 sides 20 inch minimum m the direction of travel Open the full width of the curb ramp 2011 PR0WAG R2081 AN-CR $350 54001/1/2027-1/1/2033 Fincling_638090279998S_97006 111111 The cross slope of the pedestrian access route Is excessive Pedestrian Access Rotes Remove and replace the wasting walkway Mat has an excessive Sidewalks-Finding 829822- sidewalks-Finding 829822. Sidewalks-Finding 829822- sidewalks-Finding 829822- s84 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Slope•Cross NA NA NA 003I651 105521I Re cross slope of pedestdan access routes shall be 2 percent maximum 52%-3.e% Open cross slope 2011 PR0WAG R302 6 A3S $3500 $5,2501/1/2027-1/1/2033 35 x10,350se/ft Find1ng_6380905821904_7240pg Fnding_63609050225076201p8 Finding_638030582512199). Fnding_6380905025099956 jpg There re vemcal surface discontinuities greater than 1/2 Al between 1/4 inch and 1/2 inch that are not beveled PedeztnznAccess Routes Vertical Surface Ve.cal surface discontinuities shall be 1/2 maximum al surface d es between inch an rind downt il vertical airhedi5CIOtlnmes to eliminate the Sidewalks- SIINNN9825- 597 ADA Evaluation (PAR) Sidewalks E Elkhorn Ave Curb Ramp Discontinuities NA NA 403I619 10552341/2 inch shall be beveled with a slope not steeper than 50 percent INS bevel shall be applied across the 1 OpenMPPing hazard 2011 PR0WAG R3027 2 A6CR $50 5100 1/1/2027-1/1/2033 Finding_63809028S1933_61106 The detectable warning a missing at the curb ramp Pedestrian Access Rotes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 829826- 590 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Curb Ramp Detectable Warnings Missing NA 003I606 105.5235 sides 20 inch mmnum in the direction of travel Open the full width of the curb ramp 2011 PR0W.R2081 ASCR $350 WO 1/1/2027-1/1/2033 FindIng_63809058576258040pg Re surface of Me pedestrian access route has ope g greater than 1/2inch Pedestrian Access Routes openings in gratings and joints shall not permit passage of a sphere more than 13 min(05 m)In Sidewalks-Finding 829830 SNSI_I- 602 ADA Evaluation (PAR) Sidewalks EElkham Ave Surface Horizontal Openings Greater Than l/2Inch NA 403I624 105524 diameter A Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0W.R2027 3 A55 $100 $1201/U2024-1/1/2027 Fin g_ 0905882 _641P6 The surface of the pedestrian access route has venal disconti%Mes greater than 1/2 inch or between 1/4 inch and 1/2 inch that are not beveled Pedestrian Access Rotes Vertical Surface Vertical surface discontinuities shall be 05 inch maximum Veinal surface discontinuities between 022 inch Grind down the credal surface discontinuities to eliminate the Sidewalks-Finding 829831- 603 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Surface Discontmultiez NA NA 003I625 105524 and 05 in.shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across Me 1 Open tripping hazard 2011 PR0W.R3027 2 ASS $75 $1501/1/2024-1/1/2027 FindIng_6380905889901163.0g The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes However,it z our n that %crass slope hits within Sidewalks-Finding 829835- Sidewalks•Finding 607 ADA Evaluation (PAR) Sidewalks EElkham Ave Slope•Cross NA NA NA 003I598 1055254 The crass slope of petlestnan access routes shall bet percent maximum 225%Open conventional construction toleranceIAISS S No action required 2011 PR0WAG R302 6 A35 50 So 1/U202I-1/1/2033 Fm g_ 090591I _ 21p6 Findng_636090591I0233819jpg The naming slope of pedestrian access route exceeds the general grade of the adjacent street of highway. Pedestrian Access Rotes Within Street or Hwy Where pedestrian access routes are contained within a street or highway rightaf-way the grade of Remove and replace the wasting walkway that has an excessive Sidewalks-Finding 829836- Sidewalks-Finding 829836- 608 ADA Evaluation (PAR) Sidewalks 6Elkham Ave Slope-Running{Grade) ROW NA NA 403I612 10S S25I pedestrian access routes shall not exceed the general grade established for the adjacent street or highway 970%Open coning slope 2011 PR0WAGR3025 A3S $3500 $5,2501/1/2027-1/1/2033 35x10,350se/ft Finding_63809059243798960pg Findmg_63609059251617S jpg The cross slope of the pedestrian access route II excessive Pedestrian Access Routes Remove and replace the exiting walkway that has an excessIve Sidewalks-Finding 829838- Sidewalks•Finding 630 ADA Evaluation (PAR) m Sidewalks EElkha Ave Slope 26 Cross NA NA NA 003I609 105 ce cross slope of access routes shall be 2 percent maximum 11%Open cross slope 2011 PROW.R3026 A35 50 So 1/0202I-1/1/2033 Fm g_ 0905942 _ 1pg Findm S6 6_6360905943439ejp6 The ramp nun has not been provided with edge prtechon The floor or ground surfate of the ramp run or landing shall extend 12 inches minimum beyond the inside Pedestrian Access Routes face ofa handrail aria curb or burner shall be provided that prevents the passage ofa4inch diameter sphere Sidewalks-Finding 829840- Sidewalks-Finding 829840- Sidewalks-Finding 829840- 612 ADA Evaluation (PAR) Sidewalks EElkham Ave Ramp(Not Curb Ramp) Edge rotettmn NA A NA 003I603 105525I where any potion of the sphere is within 4 inches of the finish floor or ground surface. 6 Open Install edge protection to the handrail 2011 PR0WAG P407 92 A55 $300 WO 1/1/2024-1/1/2027 Flndag_6380905955304_705.Ipg Finding_6360905956280342Ips FindIng_6380905956862_8530pg The surface of Me pedestrian access route has openings greatertM1an 1/2 inch Pedestrian Access RouterHorizontal sip nings in gratings Joints shall not permit passage of a sphere more than 13 mm(05 in)In WalkwayFindi ng 613 ADA Evaluation (PAR) walkway Rrverwalk Surface Horizontal Openings Greater Than l/21ncM1 NA 403I584 305 5228 diameter Open Repair limin the walkwayta eateoce zartl openings and 2011 PR0WAG R30273 BSS $300 51501/1/2024-1/1/202I Fin g_ 1 0906638 __6 2.Ipg The surace of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 aim(D S in)in Walkway-Finding 829905- 610 ADA Evaluation (PAR) Walkway Rnzrwalk Surface Horizontal Openings Greater Than 1/2 Inch NA 003I595 105,5224 diameter Open Repair the walkway to eliminate Openings and tripping hazard 2011 PR0WAG R3027 3 955 $250 $4001/1/2024-1/1/2027 Finding_6380906660281564.Ipg lbe surface of the pedestrian access route has vertical discontinuities greatertM1an 1/2 inch or between 1/4 inch antl 1/2 inch that are not beveled PedestrianAccess Routes al Surface surface sshall be al surface es betweenexisting flagstone,level surface andremstall flagstoneWalkwayFindmge]9848- Ks ADA Evaluation (PAR) Walkway Rrverwalk Surface Discontinuities NA NA 403I588 105 inch shall be beveled with a slope notsteeper 50 percent The bevel shall be applied across Me Open to eliminate tripping hoard 2011 PR0WAG R3027 2 B5S $150 $300 U1/2024-1/1/2027 Fin g_ 0906019 _ 06 25 The surface of the petlestnan access route has vertical discontinuities greater than 1/2 inch or between 1/4 ■ inch and 1/2 inch that are not beveled Pedestrian Routes al Surface surface disca sshall be al surface es betweenWalkway•Finding 829904- 616 ADA.-aluation (PAR) Walkway Walkway Rnzrwalk Surface Discontmulnes NA NA 403I606 105,224 and 05 inch shall be beveled with a slope not steeper 50 percent The bevel shall be applied across Me 1 Open Reinstall grate M eliminate hipping hazard 2011 PR0WAG R3027 2 955 $250 $300 1/1/2024-1/1/2027 Fin g_ 0665 _ ].Ipg The surface of the pedestrian access route has ve Alta I discontinuities greater than 1/2 inch or between 1/0 inch and 1/2 inch Mat are not beveled Pedeztnan Access Routes Vertwl000 Surface surface discontinuities shall be 05 inch maximum V ial surface discontinuities between 025 inch sting flagstone,level surface and re-mstall flagstone Walkway•Finding 829803- Walkway-Finding 829803• 619 am Evaluation (PAP) Walkway Rrverwalk Surface Disconhnmbez NA NA 0037505 1055255 and 0 s inch shall be beveled with a slope not steeper than so percent The bevel shall be applied across the Multiple at flagstone Open to eliminate tripping hazard 2011 FROWNS R3027 2 B55 $150 $3001/1/2020-1/1/2027 Fin g_ 0905980 _ s.IPg Finding_6380905986189573 jpg The running slope of the curb amp is excessive. Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curb amp shall be s percent minimum and 8.3 percent maxmum but shall not curb ramp to provide a running slope gads less Man 2011 PROW.R3022 Walkway•Finding 029805- Walkway-Finding 829805• 621 am Evaluation (PAP) Walkway Riverwalk Curb Ramp gape-N.M.,(Grade) Ramp NA 0037508 1055253 require the ramp length to exceed 15.0 ft 1050%Open o equal ro 83% 2011 FROWNS R32032 02CR $3,000 $3,5001/1/2027-1/1/2033 Finding_638090600020780I.9 Findms_63809060013I33601pg The surface of the pedestrian access route has openings greater than 1/2 inch Pedez nAccess Routes nmgz in gratings J .shall not permit passage of a sphere more than l3 mm(05 in)In WalkwayFinding 829909- ADA Evaluation (PAP)tna Walkway Rlverwalk Surface Horizontal Openings Greater Than 1/2 Inch NA 003 05521 diameter op s p pan the walkway to eliminate openings and tripping hazard 2011 PROWNG 33027 3 B55 $100 $1501/1/2020-1/1/2027 Fin g_ 0906]80 _ 1mg ]61s1-1 The pedestrian access route is not wide enough APprox 100E6 560sq/11(Cost includes removal and Pedeztnan Access Rages The continuous clear width of pedestnan access routes shall be 0.O ft minimum exclusive of the width of Me Remove and replace the ensitng sidewalk Install new sidewalk replacemem of existing Walkway•Finding 029009- Walkway-Finding 829809• 625 am Evaluation (PAP) Walkway Riverwalk Continuous Width 08 Inches Minimum Fir . NA 0037588 105525 curb 29 Open that z Ofl wide 2011 FROWNS R3023 825 $5,600 $BpW 1/1/2027-1/1/2033 sidewalk) Fin g_ W023 0506pg Findms_63809060231667Oe jpg The surface of the pedestrian access route has openings greater Man 1/2 inch Pedeztnan Access Routes openings in gratings a.m.shall not permit passage of a sphere more Man l3 min m)In Walkway•Finding 829851- Walkway-Finding 829851• 626 ADA Evaluation (PAP) Walkway Rrverwalk Surface Horizontal Openings Greater Than 1/2 Inch NA 003 Os 5252 diameter op multiple locations p pair the walkway to eliminate openings and tripping hazard 301.1 PROWNS R302]3 355 $200 $3001/1/2020-1/1/2027 Fin g_ 09W032 _ sips Finding_6380906032833558 jpg ]5921 The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access RaBez al openings rim gradngz and Joina shall no[permrc passage ofazphere more Man 13 mm105inl in Walkway•Finding 829852- Walkway-Finding 829852• 627 am Evaluation (PAP) Walkway Riverwalk surface Horizontal Openings Greater Than 1/2 Inch NA 0037507 105525 diameter 2 Open Repair the walkway to eliminate openings and tripping hazard 2011 FROWNS R30273 BSs $100 $1501/1/2020-1/1/2027 Finding_63809060392259506m6 Fin6ng_6380906000006105ms The running slope of Me turning space at the top of the curb amp exceeds 2%maximum The running slope of the curb nrnp shall cut through or shall be built up o stna e t right angles or shall n Access Routes meet.gutter grade breakThe running slope of the curb ramp Regrade the turning space of the curb ramp,so..the running Walkway•Finding 829853- Walkway•Finding 829853• 628 ADA Evaluation (PAP) Walkway Riverwalk Curb Ramp Turning Space Slope Running Perpendicular Ramp 0037552 105 5251 shall be 5 percent minimum and 83 percent maximum but shall not require the ramp length to exceed 15ft 520%Open slope does not exceed 2% 2011 PRAWNS R30022 BOCK $1,000 $1,500 1/1/2027-1/1/2033 Fintlmg_630090600I819_902.1pg Finding_6380906049069_111 jpg The grade of the pedestrian access route is too steep Pedeztnan Access RaBez Not Wallin Street or Hwy Where pedestrian access routes are not conned within a street or highway rigM1t-ofway Me grade of Remove and replace the existing walkway that has an exceszrre Walkway•Finding 829856- Walkway-Finding 829856• Walkway•Finding 029856- Walkway-Finding 829856• 631 ADA Evaluation (PAP) Walkway Riverwalk slope Running(Grade) ROW NA NA 0037535 1055207 pedesman access routes shall be 5 percent maximum 91,61% Open tuning slope 2011 FROWNS R302 5 B3s TBD TBD 1/1/2027-1/1/2033 Wee'look for alternative route Finding_638090606091511 mg Pn6ng_63809060660]9]92 jpg Fmtling_638090606]9]030I.9 Fin6ng_63809060705029N jpg The gmde of the pedestrian access route is too steep stna n Access Routes Not Within Street or Hwy contained psi in a street or g ayright-ofway the grade of Remove and replace Me existing walkway Mat has an excessiveWalkway Finding e2985]- Walkway•Finding 829857. 632 ADA Evaluation MAR) Walkway Piverwalk Slope r Peening(Grade) POW NA NA 0037505 1055247 pedestrian access routes shall be 5 percent maximum 915%Open running slope 2011 PROM.P3025 835 $75 $1001/1/2027-1/1/2033 Add menageaccessible route Finamg_6300906085215_99 fps Findmg_6380906086199_10 M6 The surface of the pedestrian access route has openings greater than 1/2 inch stna n Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 mm(OS in)in Walkway•Finding 829859- Walkway-Finding 829859• 630 ADA Evaluation (PAP) Walkway Riverwalk surface Horizontal Openings Greater Than 1/2 Inch NA 0037550 105525 diameter 13 Open Repair the walkway to eliminate openings and tripping hazard 2011 FROWNS R3027 3 855 $100 $1501/1/2024-1/1/2027 Finding_63809061000576106pg Finding_6380906100608768 mg The surface of the pedestrian access route has openings greater Man 1/2 inch Pedestnan Access Routed 636 ADA Evaluation (PAR) Walkway Piverwalk Surface Horizontal Openings Greater Than l/2Inch NA 0037545 1055246 diameter openings gratings mall not permdw passage of a sphere more than 13 mm(O s nil in 9 Open Repair the walkway to eliminate openings and tripping hazard 3011 PRAWN.Pion 3 BSS $100 $1501W2024-1/1/2027 Finding_6380906112633_8671pg The cross slope of the pedestrian access route is excessive The pedestran access route does have an excessive cross slope Pedeztnan Access Routes Howevem it s r opinion that the 205%cross slope fills within Walkway Finding 829862- Walkway-Finding 829862• 637 am Evaluation (PAP) Walkway Riverwalk slope•Cross NA NA NA 0037530 105.5203 The cross slope of pedestrian access routes shall be 2 percent maximum 285%Open conventional construction tolerance...Non required. 2011 FROWNS R302 6 835 SO So 1/1/2027-1/1/2033 Finding_638033509W118s0]068.IPg Fin6ng_6380906119096525 mg The surface of the pedestrian access route has openings greater than 1/2 inch stna n Access Routes Findinge29963- 638 ADA Evaluation (PAR) Walkway Riverwalk Surface Horizontal Openings Greater Than l/21nch NA 0037688 1055183 diameter openings gratings 1 .Mall not permitw passage of a sphere more than 13 mm(O s in)In g0 Open Repair the walkway to eliminate openings and tri,e6 harm, 2011 FROWNS R3027 3 Bss $100 $1501/1/2024-1/1/2027 Finding_6380906899986_0181pg The cross slope of the pedestrian access route is excessive Pedeztnan Access Routes and replace the Ousting walkway that has an excessive Walkway•Finding 829863- Walkway-Finding 829863• 639 am Evaluation (PAP) Walkway Riverwalk Slope•from NA NA NA 0037551 1055206 The crass slope of pedestrian access routesshall be 2 percent maximum Due to flagstone Open cross slope 2011 FROWNS R302 6 835 SO So 1/1/2027-1/1/2033 Fin g_ 06120 _ 9.wg Find1ng_6380906125563207. n Access Routes The cross slope of the pedestrian access route is excessive stna replace Me existing walkway Mathas an excessive Walkway•Finding 829860- Walkway•Finding 829864. 600 ADA Evaluation (PAP) Walkway Riverwalk slope•Cross NA NA NA 0037547 105520 The cross slope of pedestrian access routes shall be 2 percent maximum 7%-31% Open cross slope 2011 PRAWNS R3026 836 $0,200 56,300 1/1/2027-1/1/2033 35x12,020zq/ft Fin g_ 0906129 _ 2mg Findmg_6380906130190_63 jpg Finding_6380906134803099 fag Findmg_6380906137 _ M6 The cross slope of die pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the Ousting walkway that has an excessive Walkway•Finding 829867- Walkway-Finding 829867. Walkway•Finding 829867- Walkway-Finding 829867. 603 AOA Evaluation (PAP) Walkway Riverwalk Slope•from NA NA NA 0037563 105 5237 The cross slope of pedestrian access routes shall be 2 percent maximum 0%Open cross slope 2011 FROWNS R302 6 835 SO SO 1/1/2027-1/1/2033 Findlns_6380906151316259.IPg Find1ng_638090615786170 mg Fin g_ 06162 _ 6.IPg Fin6ng_6380906163011390 mg The gmde of Me pedestrian access route is too steep stna n Access Routes Not Within Street or NOG contained psi in a street or g ayright-ofway the grade of Remove and replace Me existing walkway that has an excessive Walkway•Finding 829881- Walkway•Finding 829881• 606 ADA Evaluation (PAP) Walkway Piverwalk Slope r Peening(Grade) POW NA NA 0037568 1055232 petleOrlan access routes shall be 5 percent maximum 1290%Open running slope 2011 PP0WAG P302 s 835 $2,800 50,2001/1/2027-1/1/2033 35xe,28059/ft Fln g_ 090661] _ 1.mg Finding_6380906618620_350 jpg The amp run has a running slope greater than 83%. PedezJima nAccess Routes m Rgeade Me mine so Mat Me runiinngslop oes not exceed Walkway Finding05065e29883- .7 am Evaluation (PAR) Walkway Riverwalk ampa(N CUT Pamp) Running Slope NA NA 0037552 1055227 amp runs shall have a running slope between s percent minimum and 83 percent maximum Open 83% 2011 FROWNS R0U]2 835 $3,500 $5,0001/1/2027-1/1/2033 Finding_6380906632020168.mg The cross slope of the pedestrian access route is excessive Remove and Walkway•Finding 829886- Walkway•Finding 829886. 609 ADA Evaluation (PAP) lstnan Access Routes Walkway Riverwalk Slope•Cross NA NA NA 0037586 1055228 The cross slope of pedestnan access routes shall be 2 percent maximum 530%Open cross slope `place the existing y than an excessive 2011 PP0WAG P3026 835 50 $01/1/2027-1/1/2033 Pm g_ 0906606 _ jpg Fin g_ 0303303 _ jpg The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal ha openings in gratings and Joints shall not permit passage of a sphere more than 13 m(05 in)In Walkway-Fading 829906- 651 am Evaluation (PAP) Walkway Riverwalk surface Horizontal Openings Greater Than 1/2 Inch NA 0037582 1055223 diameter 0 Open Repair the walkway to eliminate openings and tripping hazard 2011 FROWNS 0.3027 3 855 5100 $1501/1/2024-1/1/2027 Findlns_6380906663]71]86.mg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope 652 ADA Evaluation (PAP) )stnan Access Routes Walkway Riverwalk Slope•Cross NA NA NA 0037592 1055221 The cross p of pedestnan access routes shall be 2 percent maximum 2]5%Open conventional construction tolerance No action required within 2011 PROWAG R3026 835 50 $01/1/2027-1/1/2033 Fin g_ 0906668 _ Omg Finding_6380906668957_379 Ip5 The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal ha openings in gratings and Joints shall not permit passage of a sphere more than 13 m(05 in)In Walkway•Finding 829910- 655 am Evaluation (PAP) Walkway Riverwalk surface Horizontal Openings Greater Than 1/2 Inch NA 0037623 1055223 diameter 0 Open Repair the walkway to eliminate openings and tripping hard 2011 FROWNS R3027 3 855 $100 $1501/1/2024-1/1/2027 Finding_6380906686469_560.1PS The running slope of Me curb amp is excessive Pedestnan Access Routes Perpendicular or g slope of the curb amp shall be s percent minimum and 83 percent maximum but shall not e p provide a running p grade less than 20 658 ADA Evaluation (WA) Walkway Riverwalk Curb Ramp Slope Runmg(Grade) Ramp NA 0037592 1055213 require the ramp mp length to exceed 150 ft 1120%Open or equal to 83% 2011 FROWNS R30032 B2CR $3,000 $3,5001/1/2027-1/1/2033 Pm g_ 0906]06 _ 9mg Pieding_6330303,03333-33 mg The detectable warning m missing at the curb amp Pedeztnan Access Routes Curb ramps mall have a detectable warning that extends the full paid.of Me curb ramp excluding the flared InMall an ADA compliant detectable warning surface that extends Walkway•Finding 029914- 659 ADA Evaluation (PAP) Walkway Riverwalk Curb NI, Detectable Warnings Missing NA 003759 1055210 sides 20 inch minimum in the direction of travel Open Me full width of the curb amp 2011 PROW.0.2081 BSCR $350 WO 1/1/2027-1/1/2033 Finding_6380906I098217106pg The surface of the pedestrian access route has vertical discontinuities greater Man 1/2 inch or between 1/0 inch antl 1/2 inch that are not beveled stna n Access Routes nt surface dishall.es shall 05 i maximum V ial surface discontinuities between 025 inch existing flagstone,level surface and re-mstall flagstone .1 ADA Evaluation (PAP) Walkway Riverwalk Surface Discontinuities NA NA 0037595 1055218 and 0 s inch shall be beveled with a slope not01 steeper than so percent The bevel shall be applied across the 1 Open to eliminate seeping hamrd 2011 FROWNS R3027 2 B55 $150 83001/1/2020-1/1/2027 Finding_6380906716060_6481P6 The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes openings in gratings and Join.shall not permit passage of a sphere more than 13 ham(05 in)In Walkway•Finding 029923- OS ADA Evaluation (PAP) Walkway Riverwalk surface Horizontal Openings Greater Than 1/2 Inch NA 0037606 105.5216 diameter tap 2y Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 BSs $200 $3001/1/2020-1/1/2027 Finding_6380906]2]305_350.mg The cross slope of Me pedertran access route is excessive The pedestrian excessive nthat the 26%cross slope falls swithpe Walkway stnan Access Routes However,it 665 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA NA 0037605 1055210 The cross p0% of pedestnan access routes shall be 2 percent maximum 26Open conventional sconstruction tolerance No action required 2011 PROWAG R3026 835 $0 $01/1/2027-1/1/2033 Fin g_ W 09722 _ jpg Fiedg_6380306703630_080 jpg The surface of the pedestrian access route has openings greater than 1/2 inch PedeztnanAccess Routes openings in gratings Joints shall not permit passage of a sphere more than 13 min(05 in)In WalkwayFndinge29926- 666 ADA Evaluation (PAP) Walkway Rrverwalk surface Horlmnal Openings Greater Than l/21nch NA 003760 1055210 diameter 5 Open Repair the walkway to eliminate openings and tripping hazard 2011 FROWNS R30273 BSs $100 $1501/1/2020-1/1/2027 Findlns_6380906708205_122.pg The running slope of the curb amp is excessive The curb mine does have n excessAe running slope However, Pedmtnan Access Router Perpendicular or Diagonal The running slope of the curb amp shall be s percent minimum and 83 percent maximum but shall not n Mat the ru mg slope of925%falls within Walkway•Finding 829927- Walkway-Finding 829927. 667 ADA Evaluation MAP) Walkway Riverwalk Curb NI, Slope-Rummng(Grade) Pamp NA 0037619 1055212 require the ramp length to exceed 15 0ft 925%Open conventional construction tolerance No action required 2011 FROWNS R30032 02CR $ S- 1/1/2027-1/1/2033 Fin g_ WI53 0391Pg Findms_63809061505]95]0j06 Rere is no turning space at the top of the corb ramp If there is enough space provided to increase the length of the turning space,install a turning space witll the correct length A turning space.inches minimum wide by.inches minimum in the..bon of travel shall be provided at (Refer to Column N P'Fincling.for dimensions).If there is not Pedestrian Access Routes the top of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces enough space to install a turning space at the top of the curb Walkway•Finding 829945- Walkway-Finding 829945• 668 am Evaluation (PAR) Wel°. Rwenvalk Curb Ramp Turning Space Mosmg Perpendicular/Diagonal 40 37622 -105 5211 Open remP,convert the existing Perpendicular curb ramp into a 2011 PROW.R304 2 1 84.CR 5500 $1,000 1/1/2027-1/1/2033 FindIng_6380906756668_871,pg Finding_6380906757445_753,pg Re cross slope of the pedestrian acre.route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Walkway•Finding 829946- Walkway•Finding 8299.. 669 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA NA 40 37627 .105 5211 The cross slope of pedestrian access routes shall.2 percent maximum 3 45%Open cross slope 2011 PROWAG R302 6 83.5 53,600 55,400 1/1/2027-1/1/2033 0533',360./71 p.m._638.3.761807_144,pg Fin0ing_6380906762913_349.i. Re cross slope of the pedestrian access route is.cessive Re pedestrian access route does have an excessive cross slope Pedestrian Access Routes HoweveG it PS our ommon Mat Me 2 25%cross slope hIls within Walkway•Finding 829947- Walkway-Finding 829947. 670 am Evaluation (PAR) Wall.. Rwerwalk Slope•Cross NA NA Na 40 37615 -105 521 The cross slope of pedestrian access routes shall be 2 percent maxlmurn 2 25%Open conventional construction tolerance No action required. 2011 PROW.R302 6 83.5 50 $0 1/1/2027-1/1/2033 Fin2i4g_6380906769800_264gps .683,,6380906770777_710 mg The vow slope of Me pedestrian access route is excessive The pedestrian access route does have an excesove cross slope Pad...an Access Routes However,0 is our...Chat Me 2 76%cross slope falls within Walkway•Finding 829951- Walkway•Finding 829951• 673 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA Na 00 37626 .105 5204 The cross slope of pedestnan access routes shall 042 percent maximum 2 75%Open conventional construction tolerance No action required 2011 PROWAG R302 6 83.5 $0 80 1/1/2027-1/1/2033 Finding_6380906795052_9061pg Rinding_633090C705772_634.i. Re cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the wasting walkway that has an excessive Walkway•Finding 829952- Walkway-Finding 829952• Walkway•Finding 829952- Walkway-Finding 829952• 674 am Evaluation (PAM Wall.. Rwerwalk Slope•Cross NA NA Na 40 37624 -105 5203 The cross slope of pedestdan access routes shall be 2 percent maximum 4%Open cross slope 2011 PROWAG R302 6 83.5 54,400 56,600 1/1/2027-1/1/2033 55,03k 440./h Finding_6380906803023_5 tpg Finding_63809068,03630_540,pg FindIng_6380906805092_634..g Finding_6380906335817_928.3 Re cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestnan Access Routes However,it is our opinion that the 2 85%cross slope falls within Walkway•Finding 829954- Walkway•Finding 829954. 676 ADA F.luation (PAR) Walkway Riverwalk Slope•Cross NA NA NA 40 37.6 .105 5198 The cross slope of pedestnan access routes shall 022 percent maximum 2 85%Open conventional construction tolerance No action required 2011 PROWAG R302 6 83.5 $0 50 1/1/2027-1/1/2033 Pmding_6380906815759_826mg FIndin0_633090S.ke33-3101P0 Re cross slope of the pedestrian access route is.cessive Pedestrian Access Routes Remove and replace the existing walkway that h.an.cesswe Walkway•Finding 829955- Walkway-FindIng 829953. 677 am Evaluation (PAM Walkway Riverwalk Slope•Cross NA NA NA 40 37655 -105.5196 The cross slope of pedestdan access routes shall be 2 percent rnadmurn 3 90%Open cross slope 2011 PROWAG R302 6 83.5 $1,200 $1,800 1/1/2027-1/1/2033 20,6',120501 FindIng_6380906823756_904,pg Findin086380906824672_68315g The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 in.a.1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface ..cal surface diuontinuities shall.0 5 inch maximum Vertical surface discontinuities between 0 25 inch Remove existing flagstone,level surface and re-install flagstone Walkway•Finding 829956- 678 ADA Evaluation (PAR) Walkway Riverwalk Surface Discontinuities NA NA 40 37667 .105 5193 and 0 5 inch shall be beveled.01 a slope not steeper than 50 percent The bevel shall be applied across the 1.'multiple locations Open to eliminate topping hazard 2011 PROWAG R302 7 2 85.5 $150 8300 1/1/2024-1/1/2027 Finding_6380906836455_3341Pg Re cross slope of the pedestnan access route Is exceuive The pedestrian access route does Pave an excessive cross slope Pedeanan Access Ro.es However,it is our ommon Mat Me 2 75%cross slope falls within Walkway•Finding 829957- Walkway-Fincfing 829957. 679 ADA Evaluation (PAR) Walkway Rwenoalk Slope•Cross NA NA NA 40 37628 -105.5209 The cross slope of ped.trlan access routes shall be 2 percent maximum 2 75%Open conventional construction'tolerance No action required. 2011 PROWAG R302 6 83.5 II SO 1/1/2027-1/1/2033 FindIng_6380906842052_230.mg Finding_6380906842672_903 mg The crow slope of the pedestrian access route is.cessive Pedestnan Access Routes Remove and replace the existing walkway..has an excessive Walkway•Finding 829958- Walkway-Finding 829958• Walkway•Finding 829958- Walkway•Finding 829958• 680 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA Na 00 37692 .105 5193 The cross slope of pedestnan access routes shall.2 percent maximum 3 40%Open cross slope 2011 PROWAG R302 6 83.5 CO 50 2/2/2027-1/1/2022 Finding_6380906846801_676.g Rinding_6280.C.7052-C32jR2 Clc2in2-632°3.3433.-S21.22 F..."''''''-'8'jP2 The cross slope of the pedestrian access route Is exceuive Pedestrian Access Routes Remove and replace the wasting walkway that M1as an excessive Walkway-Finding 829959- Walkway-Fincfing 829959• 681 ADA Evaluation (PAM Walkway Rwerwalk Slope•Cross NA NA Na 40 37693 -105 5194 The cross slope of ped.trlan access routes shall be 2 percent maximum 3 30%Open vow slope 2011 PROWAG R302 6 0.3.1 MO 51,350 1/1/2027-1/1/2033 15.6k 9033/5 FindIng_6380906863946_881.g Findi5086380906865483_274 jpg Re cross slope of the pedestrian acre.route is excessive The pedestrian access route does have an excess.cross slope Pedestnan Access Routes However,it is our opinion that the 2 4,cross slope falls within Walkway•Finding 829960- Walkway•Finding 829960. 682 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA Na 00 37674 .105 5193 The cross slope of pedestnan access routes shall 132 percent maximum 2 40%Open conventional construction tolerance No action required 2011 PROWAG R302 6 83.5 $0 SO 1/1/2027-1/1/2033 Pm0i8g_6380906870906_896 gag Rinding_6280902271241-156j42 The ramp does n.have compliant handrails Handralls are repuired on both sides of all surfaces that are sloped greater than 5 percent(1 20)Handrails Pedestrian Access Routes most be between 34 inches and 38 inches above the rarnp surface must extend beyond the top and bottom Oue to the eosnng slope on the walkway,we recommend Walkway-Finding 829961- Walkway-Fincfing 829961• 683 ADA Evaluation (PAM Walkway Riverwalk HkmP MIM Curb Ramp) Handroa mwong Na 40 37685 -105 5188 of Me ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails must be 7 3%running slope Open Installing ADA handrails on lan.odes of the walkway 2011 PROWAG R409 1 8.5.1 $1,500 53,000 1/1/2024-1/1/2027 FindIng_6380906879819_9484pg Findin086380906880673_843158 Re cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Walkway•Finding 829962- Walkway-Finding 829962• Walkway•Finding 829962- Walkway-Finding 829962• 684 ADA Evaluation (PAR) Walkway Riverwalk Slope•Cross NA NA Na 40 3769 •105 5187 The cross slope of pedestnan access routes shall 022 percent maximum 4,5% Open cross slope 2011 PROWAG R302 6 83.5 52,800 52,700 2/2/2027-1/1/2022 3081',180./ft g.rding_63809.889284_471 tpg Finding_6380906890534_330 ipg Finding_62803.322512-6221122 F..."2-633.92e224n2-3.2iP2 The surface of the pedestrian acre.route has openings greater than 5/2 ill. Pedestrian Access RCN. Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mm(0 5 in)in Walkway-Finding 829964- 685 am Evaluation (PAM Walkway Rivemalk anTace Horlaontal Openings Greater Than 1/2 In. Na 40 377 -105 5183 diameter Open Repair the walkway00 elinnate openings and tripping hazard 2011 PROWAG R302 7 3 85.5 $100 $150 1/1/2024-1/1/2027 FindIng_6380906904358_5354pg The crow slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that h.an excessive Walkway•Finding 830008- Walkway-Finding 830008• 687 ADA F.luation (PAR) Walkway Riverwalk Slope•Cross NA NA Na 00 37695 .105 5184 The cross slope of pedestnan access routes shall 082 percent maximum 4 45%Open cross slope 2011 PROWAG R302 6 83.5 8900 51,350 1/1/2027-1/1/2033 1586',90./ft Pmdi8g_6380906910723_362mg FIndin0_6330502311355-112-GP The cross slope of the pedestrian acre.route Is exceuive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Walkway-Finding 830011- Walkway-Fincfing 830011• Walkway-Finding 830011- °so am Evaluation (PAM Walkway Rwerwalk Slope•Cross NA NA NA 40 37714 -105 5171 The cross slope of pedestdan access routes...MI.2 percent maximum 4 25%Open cross slope 2011 PROWAG R302 6 0.3.1 $4,500 $6,750 1/1/2027-1/1/2033 75I5ek 450s01N FindIng_638090693.3341158.mg Findin806380906935804848 jpg FindIng_6380306936454_459.ips Re ramp does not have compliant handrails Handrails are required on both sides of all surfaces that are sloped greater than 5 percent(1 20)Handrails Pedestrian Access Routes most be between 34 inches and 38 inches above the ramp surface must extend beyond the top and bottom Due to the existing slope on the walkway,we recommend Walkway•Finding 830014- Walkway-Finding 830014. 693 ADA F.luation (PAR) Walkway Riverwalk Ramp(Not Curb Ram. Handrail Missing NA 40 37755 .105 5167 of the ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails rnost be .8 2%running slope Open installing ADA handnils on both sides of the walkway 2011 PROWAG R409 1 135.CR 81,500 53,000 1/1/2027-1/1/2033 Rindi4g_638.06956475_561 tog Finding_6380906957520_686 ipg The ramp does not have compliant handrails Handralls are remared on both sides of all surf.%that are sloped greater than 5 percent(1 20)Handrails Pedestrian Access Routes most be between 34 inches and 38 inches above the ramp surface must extend beyond the top and bottom 0.to the eosnng slope on the walkway,we recommend Walkway-Finding 830016- Walkway-Fincfing 830016. Walkway-Finding 830016- Walkway-R..830016• sos am Evaluation (PAR) Walkway Rwerwalk HkmP MIOI Curb Ramp) Handroa mwong NA 40 3775 -105 5166 of the ra.12 inches and be parallel to the floor or ground surface The diameter of the handrails must be 7 2%running slope Open Installing ADA handrails on bo.sides of the walkway 2011 PROWAG R409 1 85.CR $3,000 $5,000 1/1/2027-1/1/2033 110' FindIng_6380906969944_428.g Finding_6380906970819_136,1pg FindIng_6380906974112_5.g Finding_6380906975207_122 jpg Re ramp does not have compliant handrails Handrails are required on both sides of all surfaces that are sloped greater than 5 percent(1 20)Handrails Pedestnan Access Routes most be between 34 inches and 38 inches above the ramp surface must extend beyond the top and bottom Due to the existing slope on the walkway,we recommend Walkway•Finding 830017- Walkway-Finding 830017. 696 ADA F.luation (PAR) Walkway Rivenvalk Rarnp 1501 Curb Ram. Handrail Missing NA 40 3773 .105 5171 of the ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails most be 6 7%running slope Open installing ADA handnils on both sides of the walkway 2011 PROWAG R409 1 135.CR $1,000 81,500 1/1/2027-1/1/2033 20' Pmding_6380906990820_7721. Rinding_628090C",e31-252jR2 The ramp does not have compliant handrails Handralls are required on both sides of all surf.%that are sloped greater than 5 percent(1 20)Handrails Pedeanan Access R.. most be between 34 inches and 38 inches above the mrnp surface must extend beyond the top and bottom 0.to the eosnng slope on the walkway,we recommend Walkway-Finding 830018- Walkway-Fincfing 830018• 697 ADA Evaluation (PAR) Walkway Rwerwalk HkmP MIOI Curb Ramp) Handroa mwong NA 40 37801 -105 5162 of the ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails must be 8 3%running slope Open Installing ADA handrails on both sides of the walkway 2011 PROWAG R409 1 8.5.CR $2,500 $3,500 1/1/2027-1/1/2033 80. FindIng_6380907003896_982.g Finding_6380907004634_4381pg Re cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that h.an excessIve Walkway•Finding 830367- Walkway-Finding 830367. Walkway•Finding 830367- Walkway-Finding 830367. 699 ADA F.luation (PAR) Walkway Riverwalk Slope•Cross NA NA NA 00 37563 .105 5237 The cross slope of pedestnan access routes shall 132 percent maximum .Open cross slope 2011 PROWAG R302 6 83.5 $0 50 2/2/2027-1/1/2022 Taming_63809.167316_259.mg Finding_6380906157861_705 Mg Tinding_63803.1.4.-,P6 IP0 F.nd."0-63....e..-3.-iR The surface of the pedestnan access mute M1as vertmal docontinurbes greater than 1/2 inch or between 1/4 In.and 1/2 inch that are not beveled Pedeanan Access RCN. Vertical Surface Verbral surface dIscontinuities shall be 0 5 inch maximum Vertical surface discontinuities between 0 25 inch Remo....flagstone,level surface and re-install flagstone Walkway-Finding 830369- 701 ADA Evaluation (PAM Walkway Rwerwalk SuHace DiscontmuMes NA NA 40 37595 -105 5218 and 0 5 inch shall be beveled waM1 a slope not steeper than 50 percent The bevel shall.applied across the 1" Open to eliminate tripping hazard 2011 PROWAG R302 7 2 85.5 $150 $300 1/1/2024-1/1/2027 FindIng_6380906716060_648.1pg The surface of the pedwtrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 in.a.1/2 inch that are not beveled Pedestnan Access Routes Vertical Surface VertIcal surn.di...notes shall!.0 5 inch maximum Vertical surface discontinuities between 0 25 inch Remove...flagstone,level surface and re-mstall flagstone Walkway•Finding 830370- 'Oa ADA Evaluation (PAM Walkway Riverwalk Surface Discontinuities NA NA 40 37622 -105 521 and 0 5 inch shall be beveled witll a slope not steeper than 50 percent The bevel shall be applied across the 1" Open to eliminate tripping ha.. 2011 PROWAG R302 7 2 85.5 8150 5200 2/2/2025-1/1/2027 7in0i8g_6380906777919_31911g The surface of the pedmtnan access route has vertical docontInurties greater than 1/2 mcM1 or between 1/4 In.and 1/2 inch that are not beveled Pedealnan Access ROY. Vertical Surf.e Verbral surface dIscontinuities shall!.0 5 inch maximum Vertical sorra...on...es between 0 25 inch GrInd down the vertical surn.dIscontinolhes to eliminate the Walkway-Finding 830371- 703 ADA Evaluation (PAR) Walkway Riverwalk SuHace Discontinulties NA NA 40 3765 -105.5198 and 0 5 in.shall be beveled with a slope not steeper than 50 percent The bevel shall.applied across the 1" Open tnpping hazard 2011 PROWAG R302 7 2 85.5 $75 $1$0 1/1/2024-1/1/2027 FindIng_6380906819615_713.g The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 in.a.1/2 inch that are not beveled Pedestrian Access Routes Vertical Surface Vertical surface di...Rites shall!.0 5 inch maximum Vertical surface discontinuities between 0 25 inch Grind down the vertical surn.discontinuities..eliminate the Walkway•Finding 830372- 7. am Evaluation (PAR) Walkway Riverwalk Surface Discontinuities NA NA 40 37656 .105 5196 and 0 5 inch shall be beveled witll a slope not steeper than 50 percent The bevel shall.applied across the 1. 2.e" tnPPing hazard 2011 PROWAG R302 7 2 85.5 $75 $150 1/1/2024-1/1/2027 Fi00i8g_6380906831839_255.6 . The surface of the pedmtnan access route M1as verMal discontinuities greater than 1/2 in.or between 1/4 ill.and 1/2 inch that are not beveled Pedealnan Access 1.1.1.5 Vertical Surface Verbral surface dIscontinuities shall!.0 5 inch maximum Vertical surface discontinuities between 0 25 inch GrInd down the vertical surfa.discontinolhes to eliminate the Walkway-Finding 830373- 705 am Evaluation (PAR) Walkway Rwerwalk SuHace Docontmulties NA NA 40 37688 -105 5194 and 0 5 inch shall be beveled waM1 a slope not steeper than 50 percent The bevel shall Ix applied across the 1" Open Inpping hazard 2011 PROWAG R302 7 2 85.5 $75 $1$0 1/1/2024-1/1/2027 FindIng_6380906855410_688.g Re running slope of the curb nrnp IS excessive The curb ramp does have an excessive running slope However,it Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb nrnp shall be 5 percent minimum and 8 3 percent maximum b.shall not is our opinion that the running slope of 9 25,falls within 2011 PROWAG R304 2 2 Walkway•Finding 830374- Walkway-Finding 830374. 706 ADA Evaluation (PAR) Walkway Riverwalk Curb RamP Slope-Running(Grade) Ild, NA 40 37619 .105 5212 require the ramp length to exceed 15 0 ft 9 25%Open conventional construction tolerance No action required 2011 PROWAG R304 3 2 82.CR $. 5- 1/1/2027-1/1/2033 Finding_6380906753504_439.g Finding_6380906754579_574 jpg The such.of the pedestrian access route has openings greater than 1/2 in. I Pedeanan Access 1.1.1.5 Horizontal openings in gratIngs and Joints shall not permit passage of a sphere more than 13 mm(0 5 in),0 Walkway•Finding 830375- 707 ADA Evaluation (PAR) Walkway Rwerwalk Surface Horlzontal Openings Greater Than 1/2 Inch NA 40 377 -105 5183 diameter Open Repair the walkway.eliminate openings a.t1ipp.08... 2011 PROW.R202 7 3 25'5 5100 $150 1/1/2024-1/1/2027 Fin2ing_6380906904358_535,. The running slope of the curb ramp A excessive Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not p to provide a running slope grade less than 2011 PROWAG R300 zz Sidewalk-Finding 830053 Flndmg030053- ]06 ADaEvaluation (PAP) Sidewalk Curb Ramp Slope-Running(Grade) Pamp NA 0037500 .1055 re the ramp length to exceed 150 h 9 SO p o qualto c3%ra z011 PPO 53,Oo0 $3,5001/1/2027-1/1/2033 Fm g_ 090I5555 _ 9ins Findmg_638090I5562I5861pg Ave091 The runningslope of the turning space at the tap of the curb ramp exceeds 2%maximum MEM WAG_CP The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall Pedesman Access Routes meet the gutter grade break at right angles where the curb a curved The running slope of the curb ramp Regndemeturning space of me cuT ramp.somatmerunning Sidewalk-Finding 830050 am Findin 830054 g ]D9 A Evaluation (PAP) Sidewalk NSt Vrain Ave Curb Ramp Turning Space Slope-Running Perpendicular Pamp Oo 37568 105.5091 shall be 5 percent minimum and 63 percent maximum but shall not require the ramp length to exceed 15ft 515%Open slope does not exceed 2% 2011 PROW.R30022 AO-CR $1,000 $1,5.1/1/2027-1/1/2033 Finding_630o90]560855828.IP8 Fndmg_636090]56138911 jp6 The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Routes openings in gratings Joints shall not permit passage of a sphere more than l3 mm(05 in)In Sidewalk-F 710 Evaluation (PAR) Sidewalk Sidewalk Surface Horizontal Openings Greater Than 1/2 Inch NA 55092 diameter op p panthe walkwayto eliminateocenings antltrippmg M1azartl 2011 PPO 3 A55 $100 $1501/1/2020-1/1/2027 Fin : : : 0]5 _ JCg OW A 30 The cross slope of the pedestrian access route is excessive en The pedestrian access route does have an excessive cross slope wAG'z] tlln63 21' Pedestrian Access ROttez g ourop�nion that[M1as s%crosszlope falls wgbn ADvaluation (PAP) Sidewalk NSt Vrain Ave Slope Cross NA NANA OD 3]5] 1055093 The cross slope ofpedestrian access routes shall be 2 percent maximum 2SO%0pen Hcnvennalc ]58.IPg The running slope of the curb rainp is excessive Pedestrian Access Routes Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not p to provide a running slope grade less than 2011 PROWAG R300 zz Sidewalk-Finding 830057 Flndmg03005]- ]32 ADA EAluatlon (PAP) Sidewalk Curb Ramp Slope-Runnmg(Grade) Ramp NA 5 re the ramp length to exceed 150 h 12% p o qualto c3%ra 2011 P $3,000 $3,5001/1/2027-1/1/2033 Fm g_ 090]5]2 _ 31pg Findmg_636090I5I330]55]jpg 11 5 090 Theu30mdasmgntmum6VOemcnezmmimumclearfloor space required at Me pushbutton is consistent O- w8M1 me gratle of me adlacent pedertran access route Accessible PedestnanSignal Slope-Parallel to the Changes m level are not permitted at required clear floor or ground space except that slopes not steeper than Regnde concrete at*accessible pedestrian signal so that the Sidewalk-Finding 630058 Sidewalk-Ending 830058- ]33 ADA Evaluation IAN) Sidewalk NSt Vain Ave Clear Floor Space Pedestrian Access Route NA NA 003]5]e 105 5096 1 08 shall be permitted 6%Open running and cross slope do not exceed 2% 2011 PROW.RON2 A35 $1,000 $1,5001/1/2027-1/1/2033 Finding_630090]5]6396110.IPg Fndmg_636090]5]]03]]s2 inn n Access Routes The cross slope of the pedestrian access route is excessive PedessnaRemove and eplace the existing walkway thathas an excessNe Sidewalk•Finding 830059 Sidewalk Finding 030059- 710 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037579 •1055o96 The cross slope of pedestrian access routes shall be 2 percent maximum 005%Open cross slope 2011 PROWAG R3026 A35 50 $0 1/1/2027-1/1/2033 P,n g_ 090I582108_010 inn Rntlmg_6380907582809_26194 The running slope of the curb ramp is excessive The curb ramp does have an excessive running slope However, Pedestrian Access Rntttez Perpendnular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but shall not Is our opinion that the running slope of 805%falls within Sidewalk-Finding 830060 Sidewalk-Ending 830060- ]15 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Curb Ramp Slope-Rii,ng(Grade) Ramp NA 0037576 1055098 require the ramp length to exceed 15.0ft 805%Open conventional construction tolerance No anon required 2011 PROW.R30032 AZCR $ $- 1/1/2027-1/1/2033 Finding_630090]5930]3625.IP8 Fndmg_636090]5901]5ee0 ins n Access Routes The cross slope of the pedestrian access route is excessive PedeRemove and eplace the existing y that has an excessry Sidewalk•Finding 630060 ding 030060- Sidewalk-Finding 630060 Finding030060- 719 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 003750 1055099 The cross slope of petlestnan access routes shall be 2 percent maximum 305%Open cross slope 2011 PROWAG R3026 A35 $3,850 $5,7751/1/2027-1/1/2033 55x7,3e5sq/h Fm g_ 090]6202 _ 01pg Fin g_ 090I620 _ 1PR Fin g_ 090]629 _ 01p6 F'...-...°763'rn2-28S1pg The cross slope of the pedestrian access route is excessive Pedessnan Access Router Remove and replace the wasting walkway that has an excessive Sidewalk-Finding 830065 Ending 830065- Sidewalk-Finding 830065 Finding 030065- 720 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037605 1055106 The cross slope of pedestrian access routes shall be 2 percent maximum 300%Open cross slope 2011 PROWAG R3026 A35 $5,200 $7,8001/1/2027-1/1/2033 65xe,520.01 Finding_6300907639803_565.IPg Fndmg_6360907640030509 ins Fin g_ 0]651 _D.IPg Findmg_636090I60092862e ins The cross slope of the curb rampIS greater than 2% Pedessnan Access Routes With Yield or Stop Perpendicular or Diagonal curb ramp to provide a cross slope grade less than or Sidewalk•Finding 630066 Sidewalk Finding 830066- 721 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Curb Pamp Slope Cross Controls Ramp 0037616 10551 maximum 320%Open equal to 2% 2011 PROWAG R30053 Al-CR $3,000 $3,500 1/1/2027-1/1/2033 P,naing_6380907650 _ Ipg Fntlmg_63a090]650]1355]jpg 0]The running slope of the turning space at the tops of the curb ramp exceeds 2%maximum The running pshall cut through or hall be built a curb at right angles hall Pedestrian Access Routes et the gutter grade breaks right angles where the curb a curved The running slope of the curb ramp Regrade the turning space of the curb ramp,so that the running Sidewalk-Finding 830067 Finding 030W]- 722 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Curb NI, Turning Space Slope-Running Perpendicular Ramp 0037619 1055107 shall be 5 percent minimum and 63 percent maximum but shall not require the ramp length to exceed 15ft 5%Open slope does not exceed 256 2011 PROW.R30022 AO-CR $1,000 $1,5001/1/2027-1/1/2033 FindIng_630090]65]509010.IP8 Findmg_636090765820315 jp6 The detectable warning a missing at the curb ramp n Access Routes have stable warning that ertentlstM1e full width of the curb ramp excluding the flared cable warning surface that extends Sidewalk•Finding 630068. 723 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Curb Pamp Detectable warnings Missing NA 0037637 1055107 sides 24 inch minimum in the direction of travel Open the full width of the compliant detectable 2011 PROWAG R2081 AN-CR $350 $000 1/1/2027-1/1/2033 Finaag_6300907659 _ 9.1Pg The detectable warning A missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADa compliant detectable warning surface that extends Sidewalk-Finding 830069• 720 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Curb Pamp Detectable Warnings Missing NA 0037591 105.5102 sides 20 inch minimum m the direction of travel Open the full widen of the curb ramp 2011 PROW.R2081 ASCR $350 $0001/1/2027-1/1/2033 FindIng_630090]66]120_616.Ipg ross slope Pedessnan Access Routes The cross slope of the pedestrian access route is excessive o w ver,0 is our nthat then 25%cross slope ute does have an excessive cfalls within Sidewalk•Finding 630071 Sidewalk Finding 0300]3- ]26 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037639 •1055111 The cross slope of pedestrian access routes shall be 2 percent maximum 225%Open conventional construction tolerance No action required 2011 PROWAG R302 6 A35 50 $0 1/1/2027-1/1/2033 Fm g_ 090]6]e _ 91p6 Rinding_6330907679592-472,pR The snared use path is not wide enough Pedestrian Access Routes The continuous clear width of pedestrian access routes shall be to oh minimum exclusive of the width of the Sidewalk-Finding 830072 Sidewalk-Ending 8300]2- ]z] ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Continuous Width 120i minimum NA NA 0037669 1055115 curb a Open Refer to Record 370 for ReccomendaHan and Pricing 2011 PROW.R302 3 Az5 $ 5- 1/1/2027-1/1/2033 Finding_6300907680389660.IPg Fndmg_636090768102D1501pg The surface of the pedestrian access route has openings greater than 1/2 inch n Access Routes Sidewalk.Finding 630075• 730 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Surface Horizontal Openings Greater Than l/21nch NA 003]]32 1055126 diameter openings gratings Joints shall not permit passage of a sphere more man 13 min(05 m)'in 26 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PROWAG P3027 3 A55 MO $3001/1/2020-1/1/2027 Finding_6380907711671_652Inn The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalk-Finding 6300]e Sidewalk-Ending 8300]e- ]33 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037774 1055155 The cross slope of pedestrian access routes shall be 2 percent maximum 010%Open cross slope 2011 PROW.R3026 A35 $6,000 $9,6001/1/2027-1/1/2033 Bore,600501 Finding_630090]]36950215.IPg Fndmg_636090773757762elpg n Access Routes The cross slope of the pedestrian access route is excessive PedessnaRemove and eplace the existing walkway thathas an excessNe Sidewalk•Finding 630079 ding 830079- Sidewalk-Finding 630079 Sidewalk Finding 0300]9- 734 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037775 1055156 The cross slope of petlestnan access routes shall be 2 percent maximum 050%Open cross slope 2011 PROWAG R3026 A35 $7,200 $10,8001/1/2027-1/1/2033 90x6,720sq/h Fm g_ 090]]50 _ 11pg Fin g_ 090]]51 _ Ipg Fin g_ 090]]53 _ 61pg Fin g_ 090]]50 _ 1pg The surface of the pedestrian access route has openings greater than 1/2 inch Pedestnan Access Routes openings in gratings Joints shall not permit passage of a sphere more than 13 min(05 m)In Sidewalk-Finding 31 735 ADA Evaluation WAR) Sidewalk NSt Vrain Ave Surface Horizontal Openings Greater Than 1/2In. NA 0037772 1055160 diameter l 00" Open Repair e walkway to eliminate openings and tripping hazard 2011 PROW.R3 b 0z]3 A55 5200 $3.1/1/20 -1/1/2027 Finding_630090]]596163.Ipg n Access Routes The cross slope of the pedestrian access route is excessive PedessnaRemove and eplace the existing walkway thathas an excessNe Sidewalk•Finding 630082 Sidewalk Finding 030062- 737 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Slope•Cross NA NA NA 0037767 105 5167 The cross slope of petlestnan access routes shall be 2 percent maximum 6%Open cross slope 2011 PROWAG R3026 A35 $0 $01/1/2027-1/1/2033 Fm g_ 090]]] _ 6.1p6 Rinding_6330907771480-124IPR The cross slope of the pedestrian access route is excessive Pedestrian Access Routes RernOVP and replace the existing walkway that has an excessive Sidewalk-Finding 830083 Finding 030063- ]38 ADA Evaluation (PAP) Sidewalk NSt Vrain Ave Slope-Cross NA NA NA Oo 3]]60 105.5167 The cross slope of pedestrian access routes shall be z percent maximum Open cross slope 2011 PROW.R302 6 A35 $0 $D 1/1/2027-1/1/2033 Finding_6300907776223822.IPg Findmg_63609077790e0e77Ipg The detectable warning a missing at the curb ramp n Access Routes have stable warning that ertentlstM1e full width of the curb ramp excluding the flared cable warning surface that extends Sidewalk•Finding 630080. 739 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Curb Pamp Detectable warnings Missing NA 003]]56 1055175 sides 24 inch maiinmumam the direction of travel Both sides of driveway Open the full width of thelcurb rmept 2011 PROWAG R2081 AS-CR $700 $8001/1/2027-1/1/2033 Finding_638090778.3609_627Inn The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalk-Finding 830085• ]Oo ADA Evaluation (PAP) Sidewalk NSt Vain Ave Surface Horizontal Openings Greater Than 1/2In. NA 003]]51 1055170 diameter 1 Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 A55 $100 $1501/1/2024-1/1/2027 FindIn6_630090]]86006_050.Ipg The detectable warning is missing at the curb ramp n Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared detectable warning surface that extends Sidewalk•Finding 630086 701 ADA Evaluation (PAR)) Sidewalk NSt Vrain Ave Curb Pamp Detectable warnings Missing NA 003]]50 1055175 sides 20 inch minimum m the direction of travel Both sides of driveway Open the full widthof thelcurb rmept 2011 PROWAG R2081 AN-CR $700 $8001/1/2027-1/1/2033 Finding_6380907789897_766.1Pg The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)In Sidewalks-Finding 830100- 702 ADA Evaluation (PAP) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than l/2Inch NA 0037073 1055238 diameter 2 Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 A55 $100 51501/1/2024-1/1/2027 FnMing_6300913910002_13I.Ipg The running slope of the curb ramp is excessive n Access Routes Perpendicular or g slope of the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not e p provide a running p grade less than 20 Sidewalks•Finding 830097 703 ADA Evaluation (PAR)) Sidewalks Moraine Ave Curb Pamp Slope Run mg(Grade) Ramp NA 0037531 1055231 require the ramp length to exceed 150 h 12%Open or equal rt 8c3%ram 2011 PROWAG R30032 A2CP $3,000 $3,5001/1/2027-1/1/2033 Fin g_ 0913801 _ Jpg Finding_6380913203045_509 ins The detectable warning A missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that ertentlstM1e full width of me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends I Sidewalks-Finding 030068- 744 ADA Evaluation (PAP) Sidewalks Moraine Ave Curb Ramp Detectable Warnings Missing NA 4037530 105.5236 sides 20 inch minimum in the direction of travel Open the full width of the curb ramp 2011 PROWAG R2081 ASCR 5350 50001/1/2027-1/1/2033 FindIng_6300913805500_76I.Ipg IwilM The cross slope of the pedestrian access route is excessive Pedessnan Access Router Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830089- Sidewalks-Finding 830089- Sidewalks-Finding e30069- Sidewalks-Finding 83o089- 745 ADA Evaluation (PAR)) Sidewalks Moraine Ave Slope•Cross NA NA NA Oo 37535 1055236 The cross slope of petlestnan access routes shall be 2 percent maximum 3,5% Open cross slope 2011 PROW.R302 6 A35 $3,000 AS.1/1/2027-1/1/2033 30 x10,3005g/ft Finding_638091.3809766,147IPs Findmg_6360913810682 2D inn FindIng_6300913 813 8 9 2_z50 ins Fndmg_6360913810553 e0]jpg The cross slope of Me pedestrian access route is excessive PeaeztnanAccess Routes Remove and replace the eunng walkway that has an excessive Sidewalks-Finding830091- Finding 0 70I ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Crass Na NA NA 003I571 1055235 The crass slope of pedestrian access routes shall be 2 percent maximum 380 p cross slope 2011 PR0WAG R3026 A35 51,200 61,0001/1/2027-1/1/2033 12x10,]Osq/ft Fin g_ 1382I _ S.Ipg Findng_6380913820)3191201pg The cross slope of the pedestrian access route is excessive The pedestrian ross n Access Routes th s nthat e225%crass slope efalls within Sidewalks•Finding 830093• Sidewalks•Finding 830093• 749 ADA Evaluation (PAR)) pe Sidewalks Moraine Ave Slope•Cross NA NA NA 003I582 1055230 The cross slope of aeaestnan access routes shall be 2 percent maximum 225 p conventional construction tolerance No anon required 2011 PR0WAG R3026 A35 $0 601/1/202I-1/1/2033 Fin g_ 0913002 _ 1mg Findin6_0330913843,03-830 lag The surface of the pedestrian access route has openings greater than 1/2 isdi peaeztnan Access Routes Horizontal openings n gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)In Sidewalks-Finding 030090- MO ADA Evaluation (PAR) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than l/21nch NA 003I6 1055230 diameter Open Repair the walkway to eliminate openings and tripping M1azard 8011 PR0W"8888 13 655 $100 $150 1/1/2020-1/1/2027 Finding_638091.3807737_113.ips The cross slope of the pedestrian access route is excessive n Access Routes replace the existing walkway that has an excessry Sidewalks•Finding 830095 Sidewalks•Finding 830095 751 ADA Evaluation Pedestrian Sidewalks Morane Ave Slope•Cross NA NA NA 003I593 1055237 The«oss slope of pedestrian access routes shall be 2 percent maximum 035%6% Open cross slope 2011 PR0WAG R3026 A35 55,600 50,0001/1/202I-1/1/2033 e0x7,560m/ft Fin g_ 0913050 _ 11pg Pndng_0380913851710_163 jag Fin g_ a13855 _ 91pg Fin g_ 0913856 _ lag The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excersrve cross slope peaeztnan Access Routes slope falls within Sidewalks-Finding 830096- Finding830096. 752 ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Cross NA Na NA 003I566 1055230 The cross slope of pedestrian access routes shall be 2 percent maximum 200 p conventional constructiontolerance No action required. 2011 PR0WAG R3026 A35 $0 $01/1/2027-1/1/2033 Findng_6300913865I00_585.Ips Findng_63809138665188001pg The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalks•Finding 83009I Sidewalks-Finding 83009I 753 ADA Evaluation (PAR)) Sidewalks Morane Ave Slope•Cross NA NA NA 003I50 1055230 The cross slope of pedestrian access routes shall be 2 percent maximum 340%Open cross slave 2011 PR0WAG R3026 A35 50,000 56,0001/1/202I-1/1/2033 SOxe,000m/ft Fin g_ 09130]0 _ Oipg Pit g_ 09138n _ lag Fin g_ a138)3 _ 2696 Fin g_ 09138I0 _ 1pg The surface of the pedestrian access route has openings greater than 1/2 inch peaeztnan Access Ronez Horizontal openings ingratings and fonts shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Fndn am 830098- I50 A Evaluation (PAR) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than 1/21nch NaNA 003I519 1055230 diameter 6 Open Repair Me walkway to eliminate Openings and tripping hazard 2011 PR0WAG R302]3 AS5 $100 $1501/1/2020-1/1/202] Findng_63009]38I89I5921.1pg The cross slope of the pedestrian access route is excessive The pedestrian n Access Routes n that the 2 4%cross slope falls swithin Sidewalks-Finding 830099 ISS ADA Ealanon (PAR)rid Sidewalks Moraine Ave Slope•Cross NA NA Na 0037511 1055237 The cross slope of aeaeztan access routes shall be 2 percent maximum 200%Open conventional constructiontolerance No anion required 2011 PPOWAG R302 6 A35 50 601/1/202I-1/1/2033 Fin g_ 0913885 _ ipg Findng_63805138065029Rz jag The cross slope of the pedestrian access route is excemve peaeztnan Access Ronez Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830100- Sidewalks-Finding 830100- Sidewalks-Finding 830100- Sidewalks-Finding 8301o0- I56 ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Cross NA NA NA 003I097 105523I The cross slope of pedestrian amen routes shall be 2 percent maximum 0 85,3 396 Open cross slope 2011 PR0WAG R302 6 A35 $3,600 $5,400 1/1/2027-1/1/2033 6046,360sq/ft Finaing_630091309108)0)O.IPg FnM1,03809138920090491pg FindIng_6300913095102_050.IPg Fndng_6380913895II38031pg The surface of Mepedestrian access route has penings greater than 1/2 inch n Access Routes Sidewalks-Finding 830101• 757 ADA Evaluation (PAR)) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than 1/2 MI Na 403I709 •10552a lord al openings gratings unpins not permita passage of a sphere more than 13 mm(05 col In 0 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PR0WAG R302 13 A55 $100 51501/1/2020-1/1/202I Finding_6380913900813_9721. The surface of the pedestrian amen route has openings greater than 1/2 inch peaeztnan Access Ronez Horizontal in openings gratings and Joins shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding 830102- 758 ADA Evaluation (PAR) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than 1/2 inn Na 003I0I7 105523I diameter 6 Open Repair Me walkway to eliminate Openings and tripping hazard 2011 PR0WAG R302 13 AS5 $100 $1501/1/2020-1/1/202I Finaing_6300913900333863.1pg The detectable warning%missing at the orb amp Pedeztnan Access Routes Curb ramps shall have a detectable waning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830103• 759 ADA Evaluation (PAR)) Sidewalks Morane Ave Curb Ramp Detectable Warnings Missing NA 403I0I5 105523I sides 20 inch minimum m the direction of travel Both sides of driveway Open Me full width of the curb ramp 2011 PR0WAG R2081 ASCR 6700 50001/1/202I-1/1/2033 Fin g_ 091390I _ 1pg The detectable warning%missing at the curb ramp peaeztnan Access Roues Curb ramps shall have a detectable waning that extends the full width of Me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830105- I60 ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Detectable Warnings Missing NA 003705I 105523I sides 20 inch minimum m the direction of travel Both sides of driveway Open the full width of Me curb ramp 2011 PR0WAG 82081 ASCR $700 $8001/1/202I-1/1/2033 Finaing_63009139])02]]25.1pg The cross slope of the pedestrian access route is excessive The pedestrian peaeztnan Access Router n that the 2 4%cross slope falls swithin Sidewalks-Finding 830100• Sidewalks•Finding 761 ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Cross NA NA NA 003705I 10552 200%Open conventional constructiontolerance No action required 2011 PR0WAG R302 6 A35 50 501/1/202I-1/1/2033 Fin g_ 0913922 _ 6.lpg Findng_638091358286IW4I2 jag 31 The surha of the pedes teshas averaldizontinurtes greater than 1/2 inch or between 1/0 Inch and 1/2 inch that are not beveled u peaeztnan Access Rattes Venni Surface Vertical surface dlsannnuoes shall be 05 inch maximum Venal surface discontinuities between 025 inch Grind down the vertlal surface discontinuities to eliminate the Sidewalks-Finding 830108- I63 ADA Evaluation (PAR) Sidewalks Moraine Ave Surface Discontmulnez NA NA 003I009 105523I and 05 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across Me Damaged asphah Open tripping hazard 2011 PR0WAG R302 12 AS5 $75 $1501/1/2020-1/1/202I Finang_6300913930006_166.1pg The detectable warning is missing at the con amp PeaeztnznAccess Router Curb rut have ectablewrning. ends tall an compliant detectable warning surface that extendsSidewalks-Finding830109- 760 ADA Evaluation (PAR) Sidewalks Morane Ave Curb Ramp Detectable Warnings Missing NA 403I394 105523I sides 20 inch minM1mumm the direction of travel extends Me width of Me curb ramp excluding the flared Open Me full width of the curb ramp 2011 PR0WAG R2081 AN-CR $350 50001/1/202I-1/1/2033 Fin g_ 091393I 6001. The cross slope of the con ramp is greater than 2%. peaeztnan Access Roues WAh Yield or Stop Perpendicular or Diagonal Reconstnict curb ramp to provide a cross slope grade less than or Sidewalks-Finding 830110- Sidewalks-Finding 830130- WS ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Slope-Cross Controls Ramp 003I392 105.5237 The cross slope of curb ramps blended transitions and turning spares shall be 2 percem maximum 880%Open equal to 2% 2011 PR0WAG R30053 A2CR $3,000 $3,5001/1/202I-1/1/2033 FnMing_6300913901I38000.1ps Fndng_63809139023I83931pg The cross slope of the pedestrian access route is excessive peaeztnan Access Router Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830111- Sidewalks-Finding 830111- I66 ADA Evaluation (PAR) Sidewalks Morane Ave Slope•Cross NA NA NA 003I381 105 5237 The cross slope of peaeztnan access routes shall be 2 percent maximum 60,3% Open cross slope 2011 PR0WAG R302 6 A35 62,000 $4,2001/1/202I-1/1/2033 35xe,280m/ft Fin g_ 09139a5 _ 61pg Findng_63809139058921313 jpg Finding_638091.3943428_7131pg The running slope of the curb ramp%excessive The curb ramp does have an excessive running slope However, peaeztnan Access Roues Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but Mall not r opinion that the running slope of 9l%falls within2011 PROWAG R300 2 2 Sidewalks-Finding 830112- Sidewalks-Finding 830112- ]6I ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Slope-Runnng(Grade) Ramp NA 00373I1 105 5237 require the ramp length M exceed 15.0 ft 9]0%Open conventional construction tolerance No action required 2011 PR0WAG R30032 A2CR $ 5- 1/1/202I-1/1/2033 Finaing_6300913955220500.1ps Findng_63809139560917I61pg The detectable warning%missing at the con ramp peaeztnan Access Routes Curb ramps shall have a detectable waning that extends the full width of Me curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends ding 830113- I68 ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Detectable Warnings Missing NA 403I303 105523I sides 20 inch minimum m the direction of travel Open Me full width of the curb ramp 2011 PR0WAG R2081 AN-CR $350 64001/1/202I-1/1/2033 Finding_6380913958123_917.1. The cross slope of the pedestrian access route is excessive peaeztnan Access Ranez Remove and replace the wasting walkway Mat has an excessive Sidewalks-Finding 830116- Sidewalks-Finding 830116. Sidewalks-Finding 830116- II3 ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Cross NA NA NA 003I5 105.5230 The cross slope of pedestrian access nouns shall be 2 percent maximum 635%Open cross slope 2011 PR0WAG R302 6 A35 52,000 $3,0001/1/202I-1/1/2033 5040,2009,ft Finaing_6300913981133810.Ips Fnding_0380913901819789..8 Finaing_6300913900272_3I6.lpg The surface of Me pedestrian access route has openings greater than 1/2 inch n Access Ronez openings in gratings aedloints shall not permit passage of a sphere more than 13 ram(05 inl In Sidewalks-Finding 83011I Sidewalks•Finding- II2 ADA Evaluation (PAR)) Sidewalks Morane Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 403I020 1055235 diameter cep 6•3loations Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0M.8302 13 A55 $300 54501/1/2020-1/1/202I Fin g_ 0913991 _ elpg Findng_63809139928131923 jpg The surface of Me pedestrian access route has openings greater than 1/2 inch peaeztnan Access Ranez Horizontal in openings gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Fn am ding 830118- 773 A Evaluation (PAR) Sidewalks Moraine Ave Surface Horizontal Openings Greater Than l/21nch NA 003I092 1055235 diameter 0 Open Repair the walkway to eliminate Openings and tripping hazard 2011 PR0WAG R302 13 AS5 $100 $1501/1/2020-1/1/202I Finaing_6300910000315200.1pg The cross slope of the pedestrian access route is excessive peaeztnan Access Router Remove and replace the existing walkway that has an excersrve Sidewalks•Finding 830119 Sidewalks-Finding 830119- 'DR ADA Evaluation (PAR) Sidewalks Moraine Ave Slope•Cross NA NA NA 003709 1055235 The cross slope of peaeztnan access routes shall be 2 percent maximum 0%Open cross slope 2011 PR0WAG R3026 A35 $0,200 56,3001/1/202I-1/1/2033 60x7,020m/ft Fin g_ 0930003 _ 1mg Findng_638091000030a16a5 jpg Findin8_6380586008707-8,2896 The detectable warning%missing at the curb ramp peaeztnan Access Rwttes Curb ramps shall have a detectable wamng that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Fnding 830120- II5 ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Detectable Warnings Missing III NA 003I511 1055235 sides 20 inch minimum m the direction of travel Open the full width of the curb ramp 2011 PR0WAG 82081 ASCR $350 $0001/1/202I-1/1/2033 Finaing_6300910009596_2I0.lpg The surface of Me pedestrian access route has openings greater than 1/2 inch Peaez nAccess Ronez openings ing g 1 is shall not permit passage of a sphere more than l3 mm(05 in)In Sidewalks-Finding830121• 776 ADA Evaluation (PAR) Sidewalks Sidewalks Moraine Ave Surface Horizontal Openings Greater Than l/21nch NA 003I522 1055230 diameter cep 0 Open Repair the walkway,eliminate ope g and tripping hazard 8011 PR0W6G R308 13 A55 $200 Soo 1/1/2020-1/1/202I Fin g_ 0910020230_05llpg The naming slope of the wrb amp is excessive peaeztnan Access Rattes Perpendicular or Diagonal The running slope of the curb ramp fiall be 5 percent minimum and 8.3 percent maxmum biz[shall not curb ramp to provide a running slope grade less Man 2011 PROWAG R3002 2 Sidewalks-Fnding 830122- III ADA Evaluation (PAR) Sidewalks Moraine Ave Curb Ramp Slope-Running(Made) Ramp NA 003I521 1055230 require the ramp length M exceed 15.0 ft UM Open or equal nto 3% 2011 PR0WAG R30032 A2CR $3,000 $3,5001/1/202I-1/1/2033 Finaing_6300910028035209.1pg The turning space at the top of the ramp is not the correct length mutingOm to layout,we Peaez nAccess Router Perpendicular/Diagonal-Length in Direction of Where the, space ackaf-sidewalk the turning p shall be 00 inches minimmistingperpendicular curb r p parallel curb end converting thisSidewalks- ding830123 Sidewalks•Finding- IIe ADA Evaluation (PAR) Sidewalks Sidewalks Moraine Ave Curb Ramp Turning pace Constrained p n 003I51I 1055235 wideby60 inches in direction ofMe ramp run 25 Open %arm 2011 PR0WAG R30421 AOCR 53,000 $3,5001/1/202I-1/1/2033 amp into parallel curb ramp b Fin g_ 0910032 _ elpg Findng_6380910033696�261pg The surface of the pedestrian amen route has openings greater than 1/2 inch Pedestrian Access Ranez Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding 830120- 779 ADA Evaluation (PAP) Sidewalks Moraine Ave Surface Harizonal Openings Greater Than 1/2 Inch NA 003I520 1055235 diameter 5 Open Repair the walkway to eliminate Openings and tripping hazard 8011 PR0W"8808 73 685 $500 $1,0001/1/2020-1/1/202I Fin g_ 10036 _ 3.lpg The ores slope of the pedestrian access route is ertesoe Pedestrian Access Routes Remove and replace the existing walkway that has an excess. Sidewalks-Frndmg830125- Frndrng830125. Sidewalks-Finding 830125- ]00 Am.-al.-Lion (PAP) Sidewalks Moraine Ave Slo e•Cross NA NA NA 0037526 1055235 The crass slope of pedestrian access routes shall be 2 percent maximum 1130%Open cross slope 2011 PROW.830 26 A35 $4,000 57,2001/1/2027-1/1/2033 60x6,480m/ft tl Fin g_ 0914039 _ 0.)pg Findmg_6360914040116395 jpg On g_ 14052 _ 6)pg ce e surfa of the pedestrian access route has openings greater than 1/2 in. ' Pedestrian Access ROM. Horizontalopenings in gratings and Joints shall net permit passage of a sphere more than 13 mm(05 in) Sid N Sidewalks 8303763 ]el ADA Evaluation (PAP) Sidewalks Moraine Ave Su Horizontal Openings Greater Than 1/2 NA 40 3752 1055235 diameter op 2 Open Repair the walkway to eliminate openings and tnppmg hazard 2011 PPOWAG1130273 A55 $100 $150 1/1/2024-1/1/2027 I FindIng_6380914019851947.IPg The cross slope of the pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding 8303]]- Finding 8303]]. Sidewalks-Finding 830377- 702 ADA Evaluation (PAP) Sidewalks Moraine Ave SI NA NA NA 40 37381 305523]mecross slope of cetlestnanacoers routes shall bet percent maximum 6696-3% P wsszlaPeIIIM A35 82,000 54,2001/1/2027-1/1/2033 Bo N On e_ 0913905 _ 6)Pg Findmg_6360913945692313 jpg Fin e_ 139 _ 3wg e surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access RwBes Horizontalopenings in gratings and Joints shall net permit passage of a sphere more than l3 mm(05 in) Sidewalks-Finding 830126- 783 ADA Evaluation (PAP) Sidewalks Post Office Parking lot Surface Horizontal Openings Greater Than 1/2 Inch NA 0037531 1055231 diameter op ] Open Repanthe walkwryto eliminateOceningz and[upping M1azard 2011 PPOWAG P302]3 B55 $100 $1501/1/2024-1/1/2027 Finding_6380914057507741.Ip0 The surface of Me pedestrian access route has openings greater than lninch Pedestrian Access Routes openings in gratings and Joints shall not permit passage of a sphere more than l3 mm(05 m)In Sidewalks-fwank 830127- Finding 830127. ADAEvaluation (PAP) Sidewalks Post Office Parking lot Surface Horizontal Openings Greater Than l/21ncM1 40 5231 darmet'al op 4 multiple locations p pair the walkway to eliminate openings and tripping hazard 2011 PRO $300 5450 1/1/2024-1/1/2027 Fin g_ 0914062 _ 3)pg Findmg_6360914063958303 jpg I I 3]50Ir The cross slope of the pedestrian access route is e<esoe WAG Pedeztnan Access Rages Remove and replace the ousting walkway that has an excessive Sidewalks-Finding 830128- Sidewalks-finding 830128- Sidewalks-Finding 830128- ]85 ADA Evaluation (PAP) Sidewalks Post Office Parking lot Slope•Cross NA NA NA 0037534 105.5228 The cross slope of petleMan access routes shall be 2 percent maximum 3OM Open cross slope 2011 PPOWAGP3026 B35 $0,000 56,0001/1/2027-1/1/2033 00 0,0o0zq/ft Finding_63809140]129]811.IPg Fndmg_6380914072571249)pg FindIng_63809140]4229818.)pg Re cross slope of the curb ramp greater than 2% Pedestnan Access Routes or Stop Perpendicular or Diagonal curb ramp to provide a cross slope gratle less than or Sidewalks•Finding 830129 Sidewalks•Finding 830129• 706 ADA Evaluation (PAP)) Sidewalks Post Office Parking Lot Curb Ramp Slope Cross Controls Ramp 0037535 1055224 The cross slope of curb ramps blended transitions and turning spaces shall be 2 percent maximum ass%Open equal to 2% 2011 PPOWAG 830053 82CR 83,000 53,500 1/1/2027-1/1/2033 Ontlag_6300914081976_609.fpg Hntlmg_6380514003 _ leg Findin8_6380814084392_2181P8 The counter slope at the gutter exceeds 5% Pedestrian Access Rwoez The counter slope of the gutter or street at the Mot of curb ramp cons blended transitions and turning spaces ftegmde the gutter/street so that the counter slope does not Sidewalks-Finding 830130- Sidewalks-Finding 83o130- ]8] ADA Evaluation (PAP) Sidewalks Post Office Parking lot Curb Ramp Slope at Gutter or Street NA NA 4037527 1055225 shall be 5 percent maximum 930%Open exceed 5%in the direction of the curb ramp run 2011 PPOWAG1130050 B2CR 55,000 $7,0001/1/2027-1/1/2033 Finding_6380914096429700.IPg Fndmg_638091409]050]31Jpg n Access Routes or Stop Perpendicular or Diagonal Re cross slope of the curb ramp greater than 2% o e u haven T6fall slopee cross swithin conventional Sidewalks•Finding 830131 786 ADA Evaluation (PAR) Sidewalks Post Office Parking Lot Curb Ramp Slope Cross Controls Ramp 0037527 1055224 The cross slope of curb ramps blended tnnsinons and timing spaces shall be 2 percent maximum 2]0%Open wnstrurnon tolerance No action required 2011 PPOWAG 830053 82CR 5 5 1/1/2027-1/1/2033 Ontlag_6300914103076_287.1pg Fintlmg_6380914103 _ .IPS The running slope of Me curb amp is exassie n Access Router rampm pendlalar or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but shall not rap to provide a running slope grade less Man 2011 PROW.830022 Sidewalks-Finding 830132- Finding 83o132- 789 ADA Evaluation (PAP)) Sidewalks Post Office Parking lot Curb Ramp Slope-Rummng(Grade) Ramp NA 40 3752 1055223 require the ramp length to exceed 15.0ft 11%Open or equal t 8[3% 2011 PROW.830032 82CR $3,000 $3,5001/1/2027-1/1/2033 Finding_6380914109570503.IPg Findmg_6 3 6 0 91411D]06235)pg Re surface of Me pedestrian access route has openings greater than lninch n Access Routes openings g g 1 is shall not permit passage of a sphere are man 13 non m)In Sidewalks Finding 830135 792 ADA Evaluation (PAR) Sidewalks Post Office Parking Lot Surface Horizontal Openings Greater Than 1/2 Inch NA 0037088 1055223 diameter4•2locations Open Repair the walkway.eliminate openings and tripping hazard 2011 PROWAG P5027 3 Bs5 5200 5300 1/1/2024-1/1/2027 Fin g_ 0914134063_547.mg Findmg_6380914138191_387 ips The cross slope of the pedestrian access route is excessive Pedestnan Access Routes Remove and replace the ousting walkway that has an excessiveSidewalks-Finding 830136- Finding 830136- Sidewalks-Finding 830136- Finding 830136. 793 ADA Evaluation (PAP)) Sidewalks Post Office Parking lot Slope•Cross NA NA NA 003]0]e 105.5224 The cross slope of pedestrian access routes shall be 2 percent maximum 380%Open cross slope 2011 PPOWAG113026 B35 $8p00 $12,6001/1/2027-1/1/2033 120,7.,040zq/ft Flnding_6300910151100_390.)Pg Fndmg_6360914142015520 jpg FindIng_6380910104156971.IPg Fndmg_6 3 6 0 91414 4]]85]0)pg The surface of Me pedestrian access route has openings greater than lninch n Access Routes openings g g 1 is shall not permit passage of a sphere are man 13 mm(05 m)In Sidewalks Finding 83013]•790 ADA Evaluation (PAP]) Sidewalks Post Office Parking Lot Surface Horizontal Openings Greater man 1/2 Inch NA 40 37011 1055222 diameter402loations Open Repair the walkway to eliminate openingsand tripping hazard 2011 PROWAG 83027 3 855 $200 5400 1/1/2024-1/1/2027 Fin g_ W14sse403_818fpg FnEngk638091<D31C3360)P0 The running slope of pedestrian access route exceeds the general grade of the adwrent street of highway. Pedeztnan Access Route Wrthln Street or Hwy Where pedestrian access route are contained wlmin a street or highway right.of-ay the grade of and replace the ousting walkway that has an excessive Sidewalks-Finding 830138- Rnding83o136- ]95 ADA Evaluation (PAP) Sidewalks Post Office Parking lot Slope•limning(Grade) ROW NA NA 0037074 105.5223 pedesman access routes shall not exceed the general grade established far the ad)acent street or highway 1340%Open running slope 2011 PROW.83025 855 $400 $600 1/1/2024-1/1/2027 8%5,40zq/ft Finding_6380914176I33904.IPg Fndmg_63609141804634]e)pg The surface of the pedestrian access route has openings greater than 1/2 in. n Access Routes Sidewalks•Finding 830139• 796 ADA Evaluation (PAP)) Sidewalks Post Office Parking Lot Surface Horizontal Openings Greater Than 1/2 Inch NA 0037033 1055223 diameter openings gratings Joints shall not permitw passage of a sphere more than 13 mm(05 m)in 20 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PPOWAG 83027 3 855 $300 5500 1/1/2024-1/1/2027 Onding_638091418.3502_223.1pg The detectable warning o missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830140- ]9] ADA Evaluation (PAP) Sidewalks Post Office Parking lot Curb Ramp Detectable Warnings Missing NA 4037433 105.5224 odes 20 inch mmmum inthe direction of travel Open the Tull width of the curb nmp 2011 PPOWAG112081 BSCR $350 54001/1/2027-1/1/2033 Finding_638091418]60036I.)pg The detectable warning a missing at the curb ramp n Access Routes have detectable warning that ertentls the full width of the curb ramp excluding the flared cable warning surface mat extends Sidewalks•Finding 830142• 799 ADA Evaluation (PAP)) Sidewalks Post Office Parking Lot Curb Ramp Detectable Wammgs Missing NA 4037056 105526 side 34 inch minimum in the direction of travel Open me full width of Mel curb rmept 2011 PPOWAG P2081 BSCR 5350 54001/1/2027-1/1/2033 Fin g_ 091420 _ 5.1. 2 The ramp does not have compliant handrails Handrails are required an both sides of all surfaces that are sloped greater than 5 percent(120)Handrails Pedestrian Access Routes must be between 30 ruche and 36 inches above the nmp surface must extend beyond the top and bottom on the walkway,we recommend Sidewalks-Fining 830143- Finding 83o103- 80o ADA Evaluation (PAP) Sidewalks W Riverside Parking lot amp(Not Curb Ramp) Handrail Missing NA 0037063 105.5225 of the ramp 12 inches and be parallel to the floor or ground surface The diameter of the handrails must be 8%running slope Open installing ADA handnillsn both odes of the walkway 2011 PPOWAG110091 B55 $1,500 $3,000 1/1/2024-1/1/2027 Finding_6380914219656913.)Pg Fn6mg_6380914220516514)pg n Access Routes Re cross slope of Me petlertrian access route is excessive replace the existing y Mat has an excessive n Remove and Sidewalks�Fiing 830144 801 ADA Evaluation (PAP)) Sidewalks WRiversitle Parking Lot Slope•Cross NA NA NA 0037389 •1055229 The cross slope of cetlestnan access routes shall be 2 percent maximum 52o%Open cross slope 2011 PPOWAG 83026 835 51,750 52,6251/1/2027-1/1/2033 25x7,175sq/ft Fin g_ 0914223 _ ].)pg Fntlmg_63809142nP30a126j00 The grade of me pedestrian access route is too step. Pedez nAccess Routes in Street or Hwy pedestriana street or highway right-ohway Me grade of replaceand the outing walkway that has an excess Sidewalks- ding 830147- Finding BDO ADA Evaluation (PAP) Sidewalks Sidewalks W Riverside Parking lot Slope•limning(Grade) ROW NA NA 0037328 1055228 pedestrian access routes shall be 5 percent maximum 925%Open running slope 2011 PPOWAG113025 B35 $060 $1,4401/1/2027-1/1/2033 166,964q/R Finding_6380914208574_944,0 Fn6mg_6380914249607_939)pg n Access Routes The cross slope of Me peexcess,.an access route is exces replace the existing y Mat has an excessive n Remove and Sidewalks�Fiing 830148 ]-805 ADA Evaluation (PAP)) Sidewalks WRiversitle Parking Slope 9 Cross NA NA NA 0037296 10552 s shall 3]5% x1 Open cross slope 2011 PPOWAG 83026 B35 51,800 52,7001/1/202]-1/1/2033 152,160sq/ft Fin g_ 0914256 _ 2)pg Fntlmg_63b091425]123I3 jpg The surface of the pedes utehasvertlal discontinuities greater than inch or between 1/0 In.and 1/2 mch that are not heeled Pedestrian Routes Vertical surface disco sshall be al surface discontinuities between rind down the vertical surface tliswnhnuities to eliminate the Sidewalks-Finding830150- Mr ADA Evaluation (PAP) Sidewalks Sidewalks W Rarside Parking lot Surface Discantinulnez NA NA 4037244 105523 an 05 inch shall be beveled with a slope 5not steperithan 50 percent The bevel shall be applied across the 1 Open topping hazard 2011 PROW.83027 2 855 $75 $150 1/1/2024-1/1/2027 Finding_63809142]6091555.)p0 The gmde of Me pedestrian access route is too steep n Access Routes Within Street or Hwycontainedwi in a street or highway right-ohway me grade of a place the existing walkway mat has an excessive e Sidewalks•Finding 830151 Sidewalks•Finding 830151 800 ADA Evaluation (PAP)) Sidewalks WRiversitle Parking Slope•Punning(Grade) POW NA NA 0037335 105523 pedestrian access rods shall be 5 percent maximum along tire walkway Open running slope 2011 PPOWAG 83025 835 53,200 540001/1/2027-1/1/2033 130x4,320m/ft Fin g_ 0914300 _ 8wg Fin g_ 0914301 _ leg Fin g_ 0914305 _ 2)pg Fin g_ 0914306 _ )pg The detectable warning o missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830152- 809 ADA Evaluation (PAP) Sidewalks ERiverside Dr Curb Ramp Detectable Wamrngs Missing NA 4037365 1055229 odes 20 inch mono=inthe direction of travel Both side of drive lane Open the full width of the curb nmp 2011 PROW.112081 BSCR $700 WO 1/1/2027-1/1/2033 Frning_6380914329233838.)pg n Access Routes Re cross slope of the pedestrian access route is exces curbramp in replace the existing y Mat has an excessive Sidewalks•Finding 830153 810 ADA Evaluation (PAP))Pede Sidewalks ERiverside Dr Slope•Cross NA NA NA 0037035 1055223 The crass p f cetlestnan access routes shall be 2 percent maximum walkway Open cross slope 2011 PPOWAG 83026 835 $0 501/1/2027-1/1/2033 Fin g_ 0914333 _ 1)pg Fntlmg_63809143305835193jpg The running slope of the curb ramp o e essre Pedestrian Access Routes Perpendicular or Diagonal curb nmp shall be 5 percent minimum and 8.3 percent maximum but shall not p to provide a running slope grade less than 2011 PROW.830022 Sidewalks-Finding 830154- finding 83o150- 811 ADA Fvalumon (PAP) Sidewalks 6Riverside Dr Curb Ramp Slope-Runnrng(Grade) Ramp NA 4037437 105.5222 require the ramp length to exceed 15.0 ft 1130%Open or equal rto c3%era 2011 PROW.830032 82CR 53,000 $3,5001/1/2027-1/1/2033 Frnding_63809143368]4_331.)Pg Fn6mg_638091433]]65236 Jpg The surface of me pedestrian access route has openings greater than 1/2 inch n Access Routes openings gratings Joints shall not perm[passage of a sphere are man 13 mm(05 m)'in Sidewalks Finding 830155• 812 ADA Evaluation (PAP)) Sidewalks ERiverside Dr Surface Horizontal Openings Greater Than 1/2 Inch NA 0037044 1055222 Horizontal oP 5 Open Repair the walkway to eliminate openings antl tripping hazard 2011 PPOWAG 83027 3 855 $100 5150 1/1/2024-1/1/2027 Onding_6380914300100_8041pg The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830156- Frndag830156- 813 ADA Evaluation (PAP) Sidewalks 6Rarside Dr. Slope-Cross NA NA NA 0037042 105.5222 The cross slope of pedestrian access routes shall be 2 percent maximum 750%Open cross slope 2011 PPOWAG113026 B35 8000 $1,2001/1/2027-1/1/2033 20M,eosq/ft Frnding_63809143030610)pg Frndmg_6360914343]28505)pg The surface of the pedestrian access route has openings greater than 1/2 inch n Access Router openings in gratings Joints shall not permit passage of a sphere more than l3 mm(05ern)In Sidewalks- an683015]- MO ADA Evaluation (PAP)) Sidewalks 6Riverside Dr Surface Horizontal Openings Greater Than 1/2 Inch NA 4037454 1055221 diameter sip 38 Open Repair the walkway to eliminate openings and tripping hazard 202.1 PPOWAG.02]3 B55 $200 $300 1/1/2024-1/1/2027 On g_ 14309 _ e.)pg The cross slope of roe pa rtron access route is excessive Pedeztnan Access Route Remove and replace the westing walkway that has an excessive Sidewalks-Rndmg830159- Findmg830159• 815 ADA Evaluation (PAR) Sidewalks 2Riverside Or Slope•Cross NA NA NA 4037461 1055221 The crass slope of pedestrian access routershall be 2 percent maximum ]40%Open cross slope 2011 PR0W,P3026 835 $400 $6001/1/2027-1/1/2033 10 x4,Mq/N Fin g_ 14353 _ 80pg Findmg_63809143541324]]1pg The cross slope of roe pedestrian access route is excessive Ped Remove and 816 ADA Evaluation (PPAPejstnan access Routes Sidewalks ERwersele Dr Slope•Cross NA NA NA 403]462 105522 The cross slope of pedestrian access routes shall be 2 percent maximum 960%Open crow slope replace the existing y than an excesxry 2011 PPOWAG R3026 83.3 52,000 53,0001/U2027-1/1/2033 50x4,2005g/N Finding_6380914360349_3441PP The surface of the pedestrian access route has openings greater than 5/2 inch Pedeztnan Access Routes Horizontal openings in gratings arr..,shall not m permit passage of a sphere more than l3 m(05 m)in Sidewalks-Finding 830174- Hndmg830174. Sidewalks-Finding 8301]4- 817 ADA Evaluation (PAR) Sidewalks 2Riverside Or Surface Horizontal Openings Greater Than l/21nch NA 40374]] 1055219 diameter 49.101 munple locations Open Pepaw the walkway to eliminate openings men.,haze. 2011 PR0WAG P3027 3 BSS $400 $600 1/1/2024-1/1/2027 Finding_638091436]343_]16., Find ng_63809143680645301pg FindIng_6380914368I33]]6.Ipg The cross slope of roe pedestrian access route is excessive n Access Routes replace the existing walkway that has an excessry Sidewalks•Finding 830181 Sidewalks•Finding 830181• 818 ADA Evaluation Pedestrian Sidewalks ERiverside Dr Slope•Cross NA NA NA 4037494 1055219 The cross slope of petlestnen access routes shall be 2 percent maximum 30%Open cross slope 2011 PR0WAG P302 6 83.3 5000 51,200 1,2027-1/1/2033 20x4,e0se, Fin g_ 09143]1 _ 0, Findng_63809143]32350]3]jpg Fin g_ 09143]3 _ Ipg The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shall have a detectable wammg that,ends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends 819 ADA Evaluation (PAR) Sidewalks 2Riverside Or Curb Ramp Detectable Warnings Missing NA 4037506 1055218 sides 24 inch minimum m the direction of travel Both sides of drive lane Open the full width of the curb amp 2011 PR0W,112081 85CR $700 $0001/1/2027-1/1/2033 The running slope of the curb rarnp is excessive n Access Routes Perpendicular or Diagonal slope of the curb amp shall be 5 percent minimum and 83 percent maximum but shall not a ramp to prowtle a running slope grade less thanSidewalks 803143830195 Sidewalks 803143830195• 820 ADA Evaluation (PAP) Sidewalks Sidewalks ERiverside Dr Curb Ramp Slope Run,(Grade) Ramp NA 4037506 5218105length to exceed 150 N 985%Open 2011 PR0WAG P30432 82CP 53,000 53,5001/1/2027-1/1/2033 ern g_ 0914382 _ 1.1pg Fntlng_63809143858369801R3 Fin g_ 0334386 _ 3.3 rewire stno turning space at the tap of the curb amp If there is enough space provided to increase the length of the turning space,install a turning space with the correct length tumors space48 inches minimum wide by48 inches minimum in the direction of travel shall be provided at (Peferto Column N"Finding"for dimensions)If there is not Pedeztnan Access Routes the top of the curb amp and shall be permitad to overlap other turning spaces and clear spaces enough spec,install a turning space at the top of the curb Sidewalks-Finding 830202- 821 ADA Evaluation (PART Sidewalks 2Riverside Or Curb Ramp Turning Space Missing Perpendicular/Diagonal 4037504 -105.5218 Open amp,convert the ex,ng perpendicular curb ramp into a 2011 PR0W,R30421 134CR WO $1,0001/1/2027-1/1/2033 FMing_63809143892177200pg There is no turning space at the top of the curb amp If there is enough space prowtled to increase the length of the turning smce, tall a turning space wnh the correct length ping space48 inches minimum wide by48 inches minimum in the direction of travel shall be provided at (Refer to Column N 9.6,9 for dimensions)If there is not mining layout,we n Access Routes p of the curb amp and shall be permitted to overlap other turning spaces and tlearspacex tall a turning space at the top of the curb and converting this curb Sidewalks-ronding830209 • - 822 ADA Evaluation (PAP) Sidewalks Sidewalks ERiverside Dr Curb Ramp Turning pace Missing Perpendicular/Diagonal 4037505 1055217 Open amp.convert Menens,Perpendicular curb ramp into a 2011 PR0WAG P30421 84CR 53,000 53,500 1,2027-1/1/2033 amp intoparallel curb ramp Fin g_ 0914392 _ ]Ipg Findng_6380914393495o5]4 jpg The cross slope of the curb amp is greater than 2%. Pedeztnan Access Routes Wrth yield or Stop Perpendicular,DiagonalIIIII Reconstruct cure br ,pro provide slope grade less than or Sidewalks-Finding 830215- ewalks-Finding 830215- 823 ADA Evaluation (PART Sidewalks 2Riverside Or Curb Ramp Slope-Cross Controls amp 403I519 105.5218 The cross slope of curb ramps blended...bons and turning spaces shall be 2percen[maximum. 565%Open wequal to 2% 2011 PR0W,1130453 82CR $3,000 $3,5001/1/2027-1/1/2033 Fnding_638091439639731, Fndmg_638091439]]285911pg The surface of the pe rtnan access route has omnings greater than 1/2 inch n Access Routes openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 nit In Sidewalks-Finding 830216• 824 ADA Evaluation (PAP) Sidewalks Sidewalks ERiverside Dr Surface Horizontal Openings Greater Than l/21nch NA 4037525 1055217 diameter op 12 Open Repair the walkway to ebmmate opening,.tripp1ne hazard 20.PR0WAG P3027 3 3,3 5250 5400 1,2024-1/1/2027 Fin g_ 0914403 _ Jpg The cross slope of the pedestrian access route Is excessive Pedeztnan Access Routes ' Pernove and replace the,sting walkway that has an excessive Sidewalks-Finding _7- ewalks-Finding 83021]- 825 ADA Evaluation IPA. Sidewalks 2Riverside Or Slope pedestriantez Cross NA NA NA 4037537 105.5215 The cross slope of pedestrian access roushall be 2 percent maximum 425%Open cross slope 2011 PR0W,P302 6 835 $1A00 $2,1001/1/2027-1/1/2033 200%140w, Finding_63809144SOS38]0538064., Fndmg_63809144111]]50 roe The cross slope of the padertnan access route is excessive Pedestnan Access Routes th and replace e existing walkway that has an excessive Sidewalks•Finding 830218 826 ADA Evaluation (PAP) Sidewalks ERiverside Dr Slope•Cross NA NA NA 4037576 1055212 The crass slope of petlestnen access routes shall be 2 percent maximum 640%Open cross slope 2011 PR0WAG P302 6 83.3 52,800 54,200 1,2027-1/1/2033 40x7,2805g/N Fln g_ 0934419 _ 8.1ng Findng_63809144198311798 in The surface of the pedestrian access route has openings greater than 5/2 inch Pedeztnan Access Routes Horizontal one.,in gratings arc..z shall not ampermit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding830219- 827 A Evaluation IPAR7 Sidewalks 2Riverside Dr Surface Horizontal Openings Greater Than l/21, NA 4037569 -1055212 diameter ] Open Repair the walkway to eliminate openings and tripping hazard 2011 PR0W,P3027 3 855 $100 $150 1/1/2024-1,2027 Fnding_63809144234894180pg There is no turning pace at the top of the curb amp If there rs enough space proveledo increase Me length of the tur ing space,install a ace WI.the correct ping space48 inches minimum wide by48 inches minimum in the direction of travel shall be provided at (Ren dingy"for dimensions)I&there length not h rig layout,we Pedeztnan Access Routes the top of the curb amp and shall be permitted to overlap other turning spaces and clear spaces enoughs top of the curb and converting this curb Sidewalks 1ng830220- 1 828 ADA Evaluation (PAR) Sidewalks ERiverside Dr Curb Remp Turning pace Mi g Perpendicular/Diagonal 4037584 3055212 Open ramp,convert the ens,Perpendicular curb ramp into a 2011 PR0WAG P30421 84CR 53,000 53,5001/1/2027-1/1/2033 amp intoparallel curb ramp ern g_55803 0934428 _841pg Findng_638091442924_323jpg The detectable warning is missing at the curb amp Pedeztnan Access Ruittes Curb ramps shall have a detectable warning that,ends the full width of the curb amp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830221- 829 ADA Evaluation (PAP) Sidewalks 2Riverside Or Curb Ramp Detectable Warnings Missing NA 4037602 105523 sides 24 inch minimum m the direction of travel Open the full width of the curb amp 2011 PR0W,112081 85CR $330 $4001/1/2027-1/1/2033 Fnding_638091.4431516203.1pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch antl 1/2 inch that are not beveled Pedeztiro nAccess Routes Vert,I.Mace VeMcal surface discontmuites shall be cel surface esbetwe rind downvertical surface tliscenbnumes to eliminate the Sidewalks-Finding830222- 830 ADA Evaluation (PA. Sidewalks ERiverside Dr Surface Dixontinuibes NA NA 4037521 1055217an,5 inch shall be beveled with a slope nutsteeper 1than 50 percent The bevel shall be applied across the 3 Open Prong hazard 2011 PR0WAG P3027 2 853 $75 5150 1/1/2024-1/1/2027 Finding_638091,13359_374I, The running slope of the curb amp is excessive Pedeztnan Access Ruittes Perpendicular or Diagonal The running slope of the curb amp shall be 5 percent minimum and 8.3 percent,,mum but Mall not curb ramp to provide a running slope grade less Man 2011 PROW,R30422 Sidewalks-Finding 830223- walks-Finding 830223- 831 ADA Evaluation (PAP) Sidewalks 2Riverside Or Curb Ramp gone-Runnmg(Grade) Ramp NA 4037607 1055213 require Me ramp length to exceed 15.0ft 13%Open orequall to 8.3% 2011 PR0W,1130432 82CR $3,000 $35001/1/2027-1/1/2033 Finding_6380914451I63_7190pg Fndmg_6380914452437182Jpg The detectable warning is missing at the curb amp Pedeztnan Access Routes Curb ramps shall have a detectable wam111.01 tP.n.the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks•Finding 830224• 832 ADA Evaluation (PAP) Sidewalks ERrverside Dr Curb Ramp Detectable Warnings Missing NA 403759 GO55213 sides 24 inch minimum m the direction of travel Open the full width of the curb ramp 2011 PR0WAG P2081 85CR 5350 5400 1/1/2027-1/1/2033 Finding_6380914454437_740, The surface of the pedestrian access route has openings greater than 1/2 inch Pedeztnan Access Routes Horizontal openings in gratings arr..,shall not DApermit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding 830226- 834 A Evaluation (PAP) Sidewalks Rrversitle Parking Lot Surface Horizontal Openings Greater Than 1/21nch NA 403]]49 1055204 darnWer 4 Open Repair Me walkway to eliminate openings and tripping hazard 2011 PR0W,P3027 3 855 $100 WO 1/1/2024-1,2027 Finding_63809144]9404_]680, slopeThe cross slope of the turning space exceeds,maximum The cross of curb ramps blen hall bet percent maximum At Pedez nAccess Routes With Yield or Stop crossings without yald or and luan midblock pedestrian street cro g the crow Mader space of the curb amp,so that the cross Sidewalks 835 ADA Evaluation (PAP)tna Sidewalks Riverside Perking Lot Curb Ramp Turningpace Slope Cross Controls 4037525 105522 slope shall be permitted to equal the street or highway ender 13%Open slope does not exceed 2% 2011 PR0WAG P30453 B4CR 51,000 51,500 1,2027-1/1/2033 Fin g_ 09144895523]jpg Findng_6380914490426_493 jpg The cross slope of the pedestrian access route Is excessive Pedeztnan Access RD,ls Pernove and replace the,sting walkway Mat has an excessive Sidewalks-Finding 830228- sidewalks-Finding 830228- Sidewalks-Finding 830228- sidewalks-Finding 830228. 836 ADA Evaluation (PAR) Sidewalks Riverside Parking Lot Slope•Cross NA NA NA 4037529 1055219 The cross slope of pedestrian access routes shall be 2 percent maximum 10,3% Open cross slope 2011 PR0WAG P3026 835 $2,800 $4,2001/1/2027-1/1/2033 35xe,280sq/N Finding_6380914492I50466.IPg Fndmg_63809144933695951pg Fintling_6380914495985_866.IPg Hn6mg_63809144967538421pe The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 inch antl 1/2 inch that are not beveled PedestnanAccess Routes Vert,I.Mace surface discontinuities shall be cel surface discontinuities between Sidewalks-Finding830230- 838 ADA Evaluation (PA. Sidewalks Riverside Perking Lot Surface Dixontinuiees NA NA 4037553 10552 5,551 shall be beveled with a slope not steeper 50 percent The bevel shall be applied across Me 6to g Open Provide an accessible rote to Me bridge 2011 PR0WAG P3027 2 853 52,000 53,000 1,2024-1/1/2027 Fin g_ 0914506 _ 1Pg 1]The running slope of the turning space at the tap of the curb amp exceeds 2%maximum The running slope of the curb amp shall cut through or shall be built unto the curb at right angles or shall Pedeztnan Access Ruittez meet the gutter grade break at right angles where the curb is curved The running slope of the curb ramp Remade the turning space of Me curb amp,so that the running Sidewalks-Finding 830231- sidewalks-Finding 830231- 839 ADA Evaluation (PAR) Sidewalks Rierslde Parking Lot Curb Ramp Turning Space Slope-Running Perpendicular Ramp 4037549 1055222 shall be 5 percent minimum and 83 percent maximum but Mall not require the ramp length to exceed 15N 6%Open slope does not exceed 2% 2011 PR0W,1130422 134CR $1,000 SAS.1/1/2027-1/1/2033 Finding_63809145289733100pg Fndmg_6380914529854182Jpg The cross slope of Me pedestrian access route is excessive Pedeztnan Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830232• Sidewalks•Finding 840 ADA Evaluation (PAP) Sidewalks Riverside Pang Lot Slope•Cross NA NA NA 4037582 1055226 The cross slope of petlestnen access routes shall be 2 percent maximum 6]0%Open cuss slope 2011 PR0WAG P302 6 833 51,000 52,700 1,2027-1/1/2033 30x6,1805g/N Fin g_ 0914534563_141pg Fntlng_63809145355853613 ins The cross slope of the pedestrian access route is excessive Pedeztnan Access Ruittez Pemove and replace the,snng walkway Mat has an excessive Sidewalks-Finding 830234- walks-Finding 830234- MU ADA Evaluation IPAR7 Sidewalks Rierslde Parking Lot Slope•Cross NA NA NA 4037539 105523 The crass slope of pedestrian access routes shall be 2 percent maximum 460%Open cross slope 2011 PR0W,P3026 835 $1,250 $1,8751/1/2027-1/1/2033 256,125sq/N Finding_6380914552340_61I.IPg Fndmg_63809145530483001pg The turning space at the top of the amp is not the correct lengthen the direction of the amp run Pedeztnan Access RoutesPerpendicular/Diagonal-Length in the Direction of m by 48 inches minimum shall be provided at the top of the curb ramp and ode a turning space that is 48"by48"and does not exceed a Sidewalks-Finding830235 Sidewalks•Finding- 843 ADA Evaluation (PAR) Sidewalks Riverside Perking Lot Curb Ramp Turningpace Unconstrained p n 4037534 1055222 shall be permitted tooerlaporoer turning spaces and clear spaces 29 Open 2%slope s y ectlon 2011PR0WAG P30421 B4CR $500 $750 1/1/2027-1/1/2033 Fin g_ 0914568 644.Ing Findng_6380914569816_733 jpg The turning space at the tap of the amp is not the correct length m the direuon of the amp run Pedeztnan Access Ruittes Perpendicular/Diagonal-Length in the Direction of A turning space 48 inches minimum by 48 inches minimum shall be provided at the top of the curb ramp and Prowde a turning space that Is 48"by48"and does not exceed a Sidewalks-Finding 830236- Sidewalks-Finding 830236- 844 ADA Evaluation (PAR) Sidewalks !Riverside Parking Lot Curb Ramp Turning Space Unconstrained Ramp Run 4037538 1055224 shall be permitted to overlap other turning spaces and clear spaces 2] Open 2%slope in any direction 2011 PR0WAG 1130421 134CR $500 $750 1/1/2027-1/1/2033 Finding_63809145]8645_]340pg Pndmg_63809145798254951pg The running slope of roe curb ramp IS excessive Pedeztnan Access Routes Perpendicular or Diagonal The running slope of the curb amp shall be 5 percent minimum and 8 3 percent maximum hurt shall not p to provide a running slope grade less than 20 Sidewalks-Finding 830237 845 ADA Evaluation (PAP) Sidewalks Riverside Perking Lot Curb Ramp Slope Punning(Grade) Ramp NA 4037527 1055223 require the ramp length to exceed 150ft 12 25%Open or egualrto c3%ra 2011 PR0WAG P30432 82CR 53,000 53,500 1/1/2027-1/1/2033 g_ 0914584083_2]91pg Findng_638091458481]3938 jpg The running slope of the curb amp is excessive I I _F Pedeztnan Access Ruittes Perpendicular or Diagonal The running slope of the curb amp shall be 5 percent minimum and 8.3 percent,,mum but shall not curb ramp to provide a running slope grade less Man 2011 PR0WAG R30422 Sidewalk-Finding 830238 walk335544ge30238- 846 ADA Evalumon (PAR) Sidewalk Big Horn Parking Lot Curb Ramp gone-Runm,(Grade) Ramp NA 4037664 105.5245 require the ramp length to exceed 15.0ft 1020%Open or equal rto 3% 2011 PR0W,R30432 82CR $3,000 $3,5001/1/2027-1/1/2033 Finding_63809146493]e]160pg Fndmg_63809146501046921pg The detectable warning 9 missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flare stall an compliant detectable warning surface that extends Sidewalk-F 847 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Curb Ramp Detectable Warnings Missing NA 403J665 1055241 sides 24 inch minimumm the direction of travel Both sides of driveway Open the full width of the curb ramp 2011 PROW.R2081 BSCR $700 $BW 1/1/2027-1/1/2033 Finding_6380914653249_382, The detectable warning 9 missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extendsthe full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalk-Finding 830241• 849 ADA Evaluation (PAR) Sidewalk Mg Horn Parking Lot Curb Ramp Detectable Warnings Missing NA . i637661 105.5242 sides 24 inch minimum m the direction of travel Both sides of driveway Open the full width of the curb ramp 2011 PROW.R2081 BSCR $700 $eW 1/1/2027-1/1/2033 Find1ng_6380914661700_474spg The detectable warning a missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable wammg that extendsthe full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalk-Finding 830242• 850 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Curb Ramp Detectable Warnings Missing NA -105 5241 sides 24 inch minimum in the direction of travel open the full width of the curb ramp 2011 PROWAG R2081 BSCR $350 $4001/1/2027-1/1/2033 Fin g_ 14666 _ elpg WThes,rfaceofthiepedestnanaceessroute has vertical discontinuities greater than 1/2 inch or between 1/4 inch aria 1/2 incM1 that are not beveled Pedestrian Access Routes Vertical Surfxe Verbcalsurface dlscanonumes shall be o S inch maximum Vertical surface discontinuities between 025 inch Grind down the vertical surface diswntinules to eliminate the 851 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Surface Discarmnulnez NA NA 40.3766 105.5238 an 05 inch shall be beveled with a slope not steeper than 50 percent The bevel shall be applied across the 1 Open tripping hazard 2011 PROWAG R3027 2 855 550 $1001/1/2024-1/1/2027 The cross slope of the curb ramp is greater than 2% Pedestrian Access Routes With`held or Stop Perpendicular or Diagonal curb p provide a cross slopes..less than or Sidewalk-Finding 830245 Finding 030245- .3 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Curb Ramp Slope-Cross Controls Ramp 4037 105524 The crass slope of curb ramps blended transitions and fuming spaces shall be 2 percent maximum 570 p equal to 2%cur 2011 PROMS R30453 82CR $3,000 $3,5001/1/2027-1/1/2033 Fin g_ 0914681 _ 11Pg Findmg_6380914602068361 jpg The turning space at the top of the ramp is not the correct length. Pedestrian Access Routes pendlcular/Dagonal-Length in the Direction of Where the turning space is constrained at the back-of-sidewalk the turning spate shall be 48 inches minimum Provide a taming space that Is WI,60"and does not exceed a Sidewalk-Finding 830246. 854 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Curb Ramp Taming Space Constrained Ramp Run 4037655 105.5238 wideby60 inches minimum in the direction of the ramp run 24 Open 2%slope in any direction 2011 PROWAG R30421 134CR $500 $7501/1/2027-1/1/2033 Finaing_6380914604990183spg The detectable warning a missing at the curb ramp n Access Routes have detectable warning that ertentls to full width of the curb ramp excluding the flared cable warning surface that extends Sidewalk•Finding 830247. 855 ADA Evaluation (PAR)) Sidewalk Big Horn Parking Lot Curb Ramp Detectable Warnings Missing NA 4037653 1055238 side 24 inch maiinM1mumam Me direction of travel open the full width of the lcurb rmept 2011 PROWAG R2081 BSCR $350 $400 1/1/2027-1/1/2033 Fin g_ 091468JOW562.Ipg The cross slope of the pedestrian access route is acessive The pedestrian access route does have an excessive cross slope Pedestrian Access Rniltez However,it s our opinion that the 28%cross slope falls wrtM1rn Sidewalk-Finding 830240 walk-Flndi48- 856 ADA Evaluation (PAR) Sidewalk Big Horn Parking Lot Slope•Cross NA NA NA 4037648 105.5238 The crass slope of pedestrian access routes shall be 2 percent maximum 280%Open convetionalconstruttlon tolerance No action required. 2011 PROW.R302 6 835 $ $- 1/1/2027-1/1/2033 Finding_6300914689464_443.Ipg Fndig_6380914SSC2046912041699g n Access Routes The cross slope of the pedestrian access route is excessivePedestna replaceRemove and Me existing walkway Mathas an excessive Sidewalks•Finding 830250 Sidewalks-Finding 830250• 858 ADA Evaluation (PAR)) Sidewalks Town Hall Plaza Slope•Cross NA NA NA 403I660 1055234 The cross slope of pedestrian access routes shall be 2 percent maximum 15%open cross slope 2011 PROWAG R3026 52S $5,200 $7,800 1/1/2027-1/1/2033 65xe,520zq/ft Findag_6300314732 _ 51pB Fintlmg_6330914]33 _ Ipg Fin g_ 0914J35 _ Ipg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Router However,it s our opinion that the 275%cross slope falls within Sidewalks-Finding 830256- Finding amg830256- 864 A Evaluation (PAR) Sidewalks Town Hall Plaza Slope NA NA NA 403] ] 1055209 The crass slope ofpedestrian access routes shall be 2 percent maximum 2J5%Open conventional tolerance No action required. 2011 PROW.R3026 B25 $o $01/1/202J-1/1/2033 Finding_6300914J6J546_666spg Findmg_6380914]68259692/pg n Access Routes The cross slope of the pedestrian guess route is excessivePedestna replaceRemove and Me existing walkway Mathas an excessive Sidewalks•Finding 830259 867 ADA Evaluation (PAR)) Sidewalks Virginia 0r Slope•Cross NA NA NA 4037733 1055 655%Open cross slope 2011 PROWAG R302 6 B35 50 101/1/2027-1/1/2033 Ron g_ 0914J9J Fi_ .Ipg ntlmg_6380914]9914]264jpg 32Thhsurfaceand inc teshas avamcaldiz ontinurt ez greater than 1/2 inch or between 1/4 Inch and 1/2 inch that are not beveled u Pedestrian Routes cal Surfae surface discontinuities shall be cal surface rind down the vertical surface discontinuities to eliminate the Sidewalks-Finding 830260- 868 ADA Evaluation (PAR) Sidewalks Sidewalks Virginia Dr Surface Discaenulnez NA NA 40.3776 105522 and 05 inch shall beo beveled with a slope not steeper50 percent The bevel shall be applied across the 1 Open topping hazard 2011 PROW.R3027 2 8.59 $75 $150 1/1/2024-1/1/2027 Finding_6380914805360_510.Ipg n Access Routes The cross slope of the pedestrian guess route is excessivePedestna replaceRemove and Me existing walkway Mathas an excessive Sidewalks•Finding 830270 870 ADA Evaluation (PAR)) Sidewalks Stanley Ave Slope•Cross NA NA NA 4037622 1055111 The cross slope of peaestnan access routes shall be 2 percent maximum 680%Open cross slope 2011 PROWAG R3026 52S $2,000 $3,OW 1/1/2027-1/1/2033 20x10,200sq/ft Fin g_ 0915599054_991pg Fntlmg_6380915599892_697 jpg The surface of the pedestrian access route has openings greater than 1/2 inch Pedestrian Access Routes al openings in gratings and loin m n s shall not permit passage of a sphere more than 13 in(05 nil In Sidewalks 830273- e73 ADA Evaluation (PAR) Sidewalks Stanley Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 4037607 105.5111 diameter 20" Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 8.59 $300 $5001/1/2024-1/1/2027 Find1ng_6 3 8 0 915 6 03113]e Jpg The detectable warning is missing at the curb ramp n Access Routes have detectable warning that extentlsthe full width of the curb ramp excluding the flared cable warning surface that extends Sidewalks•Finding 830272• 872 ADA Evaluation (PAR) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 4037611 1055111 side 24 inch maiinM1mumam the direction of travel Both sides of driveway open the full width of Mel curb rmept 2011 PROWAG R2081 BSCR $JW $BW 1/1/2027-1/1/2033 Finding_6380915608066_127 Ipg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessive cross slope Pedestrian Access Routes However,it s our opinion that the 285%cross slope falls within Sidewalks-Finding 830273- Finding 8302]3- e73 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope•Cross NA NA NA 4037611 1055111 The crass slope of pedestrian access routes shall be 2 percent maximum 285%Open conventionalconstruttion tolerance No action required 2011 PROW.R302 6 8.39 $0 $01/1/2027-1/1/2033 Finding_6380915613537295.IP8 Fn6mg_6380915614176242., sive cross slope Pedestnan Access Routes The cross slope of the pedestrian access route is excessive h pedestrianaccess slope falls withinSidewalks•Finding 830275 ver,it is our opinion Mat Me 2 75%cross 875 ADA Evaluation (PAR)) Sidewalks Stanley Ave Slope•Cross NA NA NA 4037556 1055111 The cross slope of pedestrian access routes shall be 2 percent maximum 275%Open conventional construction tolerance No action required 2011 PROWAG R3026 1335 50 $01/1/2027-1/1/2033 Fin g_ 0915626 _4.Ip6 Fntlmg_6300915627192_044 jpg The detectable warning 9 missing at the curb ramp Pedestrian Access Routes Curb ramps shall have a detectable warning that extendsthe full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 8302J6- e]6 ADA Evaluation (PAR) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 4037516 1055111 sides 24 inch minimum in the direction of travel Open the full width of the curb ramp 2011 PROW.R2081 BSCR $350 $4001/1/2027-1/1/2033 Finding_6380915629019655.Ipg The surface of Me pedestrian access route has openings greater than 1/2 inch n Access Routed Sidewalks.Finding 8302JJ• 877 ADA Evaluation (PAR)) Sidewalks Stanley Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 4037578 1055111 diameter openings gratings Joints sell not permit passage of a sphere more than 13 mrn(05 m)'in 6 open Repair the walkway to eliminate openings antl tripping has.. 2011 PROWAG R3027 3 R55 $100 $150 1/1/2024-1/1/2027 Finding_6380915635991_239, The cross slope of the pedestrian access route is excessive Pedestrian Access Routes Remove and replace the exiting walkway that has an excessive Sidewalks-Finding 830278- Finding e]e ADA Evaluation (PAR) Sidewalks Stanley Ave Slope•Cross NA NA NA 4037502 105.5111 The cross slope of pedestrian access routes shall be 2 percent maximum 4%Open cross slope 2011 PROW.R302 6 8.39 $1,050 $1,5751/1/2027-1/1/2033 15 xJ,105501 Finding_6380915639062_796.IP8 Fndmg_6380915639629_71 jpg The surface of Me pedestrian access route has openings greater than 1/2 inch n Access Routed openings g g 1 is sell not permit passage of a sphere more than 13 mm(05 mliin Sidewalks.Finding 830281• 881 ADA Evaluation (PeAtle)) Sidewalks Stanley Ave Surface Horizontal Openings Greer Than l/2Inch NA 4037389 •1055111 Horizontal 3 open Repair the walkway o eliminate openings a tripping has.. 2011 PROWAG R3027 3 R55 $100 $150 1/1/2024-1/1/2027 Finding_6380915662285_187.1pg The cross slope of the pedestrian access route is excessive Pedestrian Access Routed Rernove and replace the wasting walkway that has an excessive Sidewalks-Finding 030283- Finding 830203• 883 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope-Cross NA NA NA 4037333 105511 Re cross slope of pedestrian access routes shall be 2 percent maximum 5 85%Open cross slope 2011 PROW.R302 6 8.39 $1,600 $2,469 1/1/2027-1/1/2033 20xe,160501 Find1ng_6380915675518214.IP6 Findmg_63809156762658369g The detectable warning a missing at the curb ramp n Access Routes have detectable warning that extends the full width of the curb ramp excluding the flared cable warning surface that extends Sidewalks•Finding 830284• 804 ADA Evaluation (PAR)) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 4037304 •1055108 side 24 inch maiinM1mumam the direction of travel open the full width of Mel curb rmept 2011 PROWAG R2081 BSCR $350 $4001/1/2027-1/1/2033 Finding_6380915680781_150, The surface of the pedestrian assess route has openings greater than 1/2 inch Pedestrian Access Routes al openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 nil In Sidewalks-Finding 830286 1230_3- 886 ADA Evaluation (PAR) Sidewalks Stanley Ave Surface Horizontal Openings Greater Than 1/2 Inch NA 4037273 1055107 diameter 5 Open Repair the walkway to eliminate openings and tripping hazard 2011 PROW.R3027 3 859 5100 $150 1/1/2024-1/1/2027 Fining_6380915691930345spg n Access Routes Re cross slope of the pedestrian access route is excessivePedestna replaceRemove and Me existing walkway Mathas an excessive Sidewalks•Finding 830287• 887 ADA Evaluation (PAR)) Sidewalks Stanley Ave Slope•Cross NA NA NA 4037260 1055107 The crass slope of peaestnan access routes shall be 2 percent maximum 450%Open cross slope 2011 PROWAG R3026 133S $1,600 $2,4W 1/1/2027-1/1/2033 20xe,160sq/ft Findin g_6300915695 _ 2.ip6 The cross slope of the pedestrian access route is excessive 2635J Pedestrian Access Routes Rernove and replace the westing walkway that has an excessive Sidewalks-Finding 830288- Sidewalks•Finding 830288- -I 888 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope-Cross NA NA NA 4037234 105.5104 The crass slope of pedestrian access routes shall be 2 percent maximum J%curb ramp in walkway Open crossslope 2011 PROWAG R3026 8.39 $0 $0 1/1/2027-1/1/2033 Finding_6380915705690981spg Fin6ng_638091570641087 jpg There is no turning space at the top of the curb ramp If there is enough space provided to increase the length of the tall a turning space with the correct length ping spa..inch.minimum wide by 48 inches minimum in the direction of travel shall be provided at (Refer to Column N"Finding"for dimensions)If there is not n Access Routes p of the curb ramp and Mall be permitted to overlap other turning seces and clear spacesinstall turning p of the curb Sidewalks•Finding 830289 809 ADA Evaluation (PAR)) Sidewalks Stanley Ave Curb Ramp Turning pace Mi g Perpendicular/Diagonal 4037233 1055104 J85%running slope open ramp.convert Meexstingperpendicular curb ramp ins a 2011 PROWAG R30421 8403 $500 $1,000 1/1/2027-1/1/2033 Fin g_ 0915J11 Fin g_ 0915J11 Ipg _ IDB _ The detectable warning 9 missing at the curb ramp 1 Pedestrian Access Routes Curb ramps shall have a detectable warning that ertendzthe full width of the curb ramp excluding the flared Install an ADA Compliant detectable warning surface that extends Sidewalks-Finding 830290- 890 ADA Evaluation (PAR) 9wal� Stanley Ave Curb Ramp Detectable Warnings Missing NA 403J229 1055104 sides 24 inch m m wiwill inimu in the direction of travel Both aides of drive lane Open the full dth of the curb ramp 2011 PROWAG R2U81 BSCR $JW W SB 1/1/2027-1/1/2033 Fmding_6380915J18365_29 Jpg 1 de The cross slope of Me pedestrian access route is excessive PetleStnan Access Router Remove and replace Me existing walkway that has an excessive Sidewalks-Finding 830291- Sidewalks-Finding 830291- Sidewa11,5-Fmtlmg830291- 891 ADA Evaluation (PAR)) Sidewalks Stanley AVe Slope•Cross NA NA NA 40 3721 10551 The crass slope of peaetnan access routes shall be 2 percent maximum 430%Open cross slope 2011 PROW.R302 6 839 $3,200 $49W 1/1/2027-1/1/2033 40iie,320501 Fxnaing_63809157284358291P8 Fndmg_6380915729159661Pg Fxnding_6380915731741418.ipg The cross slope of me pedestrian acres,route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding830292- Finding 830292• 892 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope•Cross NA NA NA 0037185 1055096 The crass slope of pedestrian access routes shall be 2 percent maximum ]50%Open cross slope 2011 PROW.R3026 835 $960 51,0001/1/2037-1/1/3033 12x8,OWN Fin g_ 15I3] _ 90pg Findmg_6380915]30395539)pg The detectable warning is missing at We curb ramp n Access Routes ramps shall have a detectable warning that extends We full width of the curb ramp excluding the flared detectable warning surface that extends 893 ADA Evaluation (PAR)) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 003730 1055VN sides 20 inch minimum m the direction of travel Both sides Open We full aWdthof We curbramptE 2011 PROWAG R2081 BSCR 5700 $8001/1/2037-1/1/3033 Finding_6300915701098_1501pg The cross slope of the pedestrian acres,route is excessive Pedestrian Access Routes Remove and replace the existing walkway that has an excessive Sidewalks-Finding030290- Sidewalks-Finding830290- Finding830290. 890 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope•Cross NA NA NA 0037181 105.5090 The crass slope of pedestrian access routes Wall be 2 percent maximum 0 p cuss slope 2011 PROW.R3026 833 $7,200 $10,8001/1/2037-1/1/3033 110x6,]0m/ft Finding_6300915I500o]35tpg Findmg_6380915]5803]98311pg Fmding_6300915I52072920.IPg Findmg_6380915]538511]3.3 The running slope of pedestrian acres,route exceeds the general grade of the ad tit street of highway Pedestnan Access Routes WWin Street or Hwy Where pedestrian access routes are contained within a street or highway right.of-way the grade of Remove and replace the existing walkway that has an excessive Sidewalks•8nd1nge30295 895 ADA Evaluation (PAR)) Sidewalks Stanley Ave Slope Pun Ing(Grade) ROW NA NA 4037181 1055093 pedestrian access routes shall not exceed the general grade established for the adjacent street or highway 12%Open running slope 2011 PROWAG R3025 833 5500 51501/1/2037-1/1/3033 5,0,SOaq/ft Fin g_ 0915I60 _ 3gag Finding_6380915765601_529 in The cross slope of the pedestrian acres,route is excessive Pedestrian Access Routes Remove and replace the eating walkway that has an excessive Sidewalks-F inding830298- Finding 8328. 898 ADA Evaluation (PAR) Sidewalks Stanley Ave Slope•Cross NA NA NA 0037062 105,5065 The cross slope of pedestrian accessr..Wall be 2 percent maximum 950%Open cross slope 2011 PROW.R3026 83S 51,300 51,0001/1/2037-1/1/3033 30x6,130m/ft Finding_6300915I919823130pg Findmg_63809157900159153 fps The running slope of pedestrian access route exceeds the general grade of the adjacent street of highway StreetWithin or Hwy th pedestrian access routes are contained within a street or highway right.of-way e grade of and replace the existing walkway that has an excessive 900 ADA Evaluation (PAR) Pedestrian Access Routes)) Sidewalks Stanley Ave Slope Pun Ing(Grade) ROW NA NA 003700 1055061 pedestrian access routes shall not exceed the general grade established for the adjacent street or highway 12%Open ru ning slope 2011 PROWAG R302 5 835 $500 $1501/1/2027-1/1/2033 5,0,50aq/ft Fin g_ 0915805 _ 91pg Pinflice_533095SPOPOP5-2P2 ipg The detectable warning is missing at the curb ramp Pedestrian Access Roues Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830301- 901 ADA Evaluation (PAP) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 0037003 105506 sides 30 inch minimum in the direction of travel Open thefull width of the curb ramp 2011 PROWAG 0.2081 BSCR $350 8400 1/1/3037-1/1/3033 Findmg_630091580]9]8268.1pg The running slope of pedestrian access route exceeds the general grade of the adjacent street of highway n Access Routes Street or Hwy th pedestrian access routes are contained within a street or highway right.of-way e grade of th and replace e existing walkway that has an excessive Sidewalks-Finding 830302 902 ADA Evaluation (PAR)) Sidewalks Stanley Ave Slope Pun Ing(Grade) ROW NA NA 0037036 105506 pedestrian access routes shall not exceed We general grade established for the adjacent street or highway 1350%Open running slope 2011 PROWAG R302 5 835 $1,000 51,5001/1/2037-1/1/3033 5,0,100m/ft Fin g_ 0915812 _ 21pg Findmg_6380915813809o506iP8 The detectable warning is missing at the curb ramp Pedestrian Access Roues Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830303- NM ADA Evaluation (PAP) Sidewalks Stanley Ave Curb Ramp Detectable Warnings Missing NA 0037039 1055050 sides 20 inch minimum in the direction of travel Open the full width of the curb ramp 2011 PROW.0.2081 BSCR $350 WO 1/1/2027-1/1/2033 Finding_6300915810896_010.1pg The cross slope of the pedestrian acres,route is excessive The pedestrian n Access Routes n that the 2 5%cross slope falls swithin Sidewalks•Finding 830307 907 ADA Evaluation (PAR)ria Sidewalks Manfortl Slope•Cross NA NA NA 0037200 1055051 The cross slope of pedestrian access routes shall be 2 percent maximum 250%Open conventional constructiontolerance No action required 2011 PROWAG R3026 C33 $0 $0 1/1/2033-1/1/2038 Fin g_ 0915908 _ 1pg Findmg_538055SPAP010o625ipg The surface of the pedestrian acres,route has openings greater than 1/2 i510 Pedestrian Access Roinez Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Fa walks ding 8303oe- 908 ADA Evaluation (PAP) Side Manfortl Surface Horizontal Openings Greater Than l/31nch NA 003Io]] 10S S011 diameter 6 Open Repair We walkway..eliminate openings and tripping hazard 2011 PROW.R302]3 C55 $250 $3001/1/2ub-1/1/2027 Finding_6380915958806_009.1pg The turning space at the tap of the ramp is not the correct length in the direction of the ramp run Pedestnan Access RoutesPerpendicular/Diagonal Length in the Direction of A turning Space.inches minimum by 4E inches minimum shall be provided at the top of the curb ramp and Provide a turning space that is OB"by OB and does not exceed a Sidewalks-Finding 830309 909 ADA Evaluation (PAR)) Sidewalks Manfortl Curb Ramp Turning Space Unconstrained Rill,Pun 4037025 1055001 shall be permitted to overlap other turning spaces and clear spaces 32 Open 2%slope s y direction 2011 PROWAG R30421 CACR $500 $750 1/1/2033-1/1/3038 Fin g_ 09159]0 _ 01pg Pinflice_533095SP752P0-P.M8 The detectable warning is missing at the curb ramp Pedestrian Access Roues Curb ramps shall have a detectable wammg that extends the full widd)of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding830310- NO ADA Evaluation (PAP) Sidewalks Manfortl Curb Pamp Detectable Warnings Missing NA 0037051 1055 sides 30 inch minimum m the direction of travel Open the full width of the curb ramp 2011 PROW.0.2081 CSCR $350 54001/1/2033-1/1/2038 Finding_6300915973063_3620pg The cross slope of We curb ramp is greater than 2% Pedestrian Access Routes With yield or.. Perpendicular or Diagonal u br tle p to provide a cross slope gra less than or Sidewalks-Finding830311 s 911 ADA Evaluation (PAR) Sidewalks Hanford Curb Ramp Slope Cass Controls p 4037049 •105 n95 The cross slope of curb a blended ramps blenderansieons and turning spaces shall 2 percent maximum 565%Open galto2% 2011 PROWAG R30053 C2CR $3,000 $3,500 1/1/2033-1/1/3038 Fin g_ 0915985 _ ipg Finamg_6380915e60191931 ipg The detectable warning is missing at the curb ramp Pedestrian Access Rottes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830312- 912 ADA Evaluation (PAR) Sidewalks Manfortl Curb Ramp Detectable Warnings Missing NA 003I049 10S 0991 sides 30 inch minrmum m the direction of Navel Open the full width of the curb ramp 2011 PROW.R2081 CSCR $350 8400 1/1/2033-1/1/2038 Findtag_6300915988566161.1pg The cross slope of the pedestrian access route is excessive The pedestrian access route does have an excessrv.cross slope Pedestrian Access Roinez However,0 s our opinion that the235%crass slope falls within Sidewalks-Finding830313- Finding830313. 913 ADA Evaluation (PAR) Sidewalks Manfortl Slope•Cross NA NA NA 0037038 105 497 The crass slope of petleztran access routes shall be 2 percent maximum 235%Open conventional construction tolerance No action required 2011 PROWAG R3026 C33 $0 60 1/1/2033-1/1/2038 Fin g_ 091601] _801pg Findmg_6380916010090915 in The surface of the pedestrian acres,route has openings greater than 5/2 incli Pedestrian Access Routes Horizontal openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding 830319- 919 ADA Evaluation (PAP) Sidewalks Commun Dr Surface Horizontal Openings Greater Than 1/21n. NA 0037008 1055 diameter 50'damaged asphalt Open Repair the walkway..eliminate openings and tripping hazard 2011 PROW.R3027 3 855 54,000 56,0001/1/2024-1/1/2027 50,03),O00sq/N Finding_63009160915769330pg The running slope of We curb ramp IS excessive Pedestrian Access Router Perpendicular or Diagonal The running slope of the curb ramp shall be 5 percent minimum and 83 percent maximum but shall not Reconstruct cu.ramp to provide a running slope grade less than 2011 PROWAG R304 2 2 Sidewalks-Finding830321- Finding 830321• 921 ADA Evaluation (PAR) Sidewalks Community Dr Curb Ramp Slope Running(Grade) Pamp NA 4036745 1055002 require the ramp length to exceed 150ft 1350%Open or equal to 83% 2011 PROWAG R30432 C3CR $3,000 63,500 1/1/2033-1/1/2038 Fin g_ 0916108 _Olpg Findmg_6380916100953631pg The detectable warning is missing at the curb ramp Pedestrian Access Roines Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830322- 922 ADA Evaluation (PAP) Sidewalks Community Dr Curb Ramp Detectable Warnings Missing NA 0036723 1055 sides 20 inch minimum in the direction of travel Both sides Open the full width of the the street crossing at the shared use path 2011 PROW.R2081 CSCR $700 WO 1/1/2033-1/1/2038 Finding_63009161333891000pg The detectable warning is missing at We curb ramp Pedestrian Routes Curb rampshave the direction ends We full width of the curb ramp excluding the flare tall an detectable warning surface that Sidewalks- 920 ADA Evaluation (PAR) Sidewalks Sidewalks Community Dr Curb Ramp Detectable Warnings Missing NA 4036702 1055001 sides 20 inch minmumm the direction of travel extends Both sides Open the full width of the lthe lstreet crossing at the shared use path nds 2011 PROWAG R2081 CSCR $700 $800 1/1/2033-1/1/2038 Finding_6300916134294_1561ug The surface of the pedestrian acres,route has openings greater than 1/2 Inch Pedestrian Access RW.es openings in gratings and Joints shall not permit passage of a sphere more than 13 min(u S in)in Sidewalks-Finding 830325- 925 ADA Evaluation (PAP) Sidewalks Community Dr Surface Horizontal Openings Greater Than 1/31nch NA 0036653 105.5001 diameter ] Open Repair the walkway..eliminate openings antl tripping hazard 2011 PROWAG 63027 3 C55 $100 $1501/1/2020-1/1/2027 Finding_6300916100003983.1pg The surface of the pedestrian access route has vertical discontinuities greater than 1/2 inch or between 1/4 in.antl 1/2 inch that are not beveled Pedestrian Access Routes VerticalSurface Ve.cal surface discontinuities shall!.05 inM1 maximum Vertiwi surface discontinuities between 025 inch Sidewalks•Finding830327 Finding830337. 937 ADA Evaluation (PAR) Sidewalks Community Dr Surface Discontinuities NA NA 4036691 1055000 an.5 inch shall be beveled witM1 a slope not steeper than 50 percent The bevel shall be applied across the 3 multiple locations Open Repair the walkway to eliminate the vertical tripping hazard 2011 PROWAG R302]2 C5S $300 $5001/1/2020-1/1/2027 Finding_638091615808625 Jpg Findmg_6380916150915153 ipg The surface of the pedestrian acres,route has openings greater than 1/2 in. Pedestrian Access RW.es Horizontal DA openings in gratings and Joints shall not permit passage of a sphere more than 13 min(05 in)in Sidewalks-Finding 830329- 929 A Evaluation (PAR) Sidewalks Community Dr Surfadiameter Horizontal Openings Greater Than 1/31nch NA 0036591 1055008 dmeter 9 Open Repair the walkway..eliminate openings and tripping hazard 2011 PROW.R3027 3 85.5 $100 $1501/1/2020-1/1/2027 Finding_63009161]903]1260pg The cross slope of We pedestrian.cress route is excessive Pedestrian Access Routes Remove and replace the exiting walkway that has an excessive Sidewalks-F inding830330- MO ADA Evaluation (PAR) Sidewalks Community Dr Slope•Cross NA NA NA 0036045 1055028 The crass slope of petleztran access routes shall be 2 percent maximum 590%Open cross slope 2011 PROWAG R302 6 C33 $2,000 $3,600 1/1/2033-1/1/2038 30x8,200sq/ft Finding_6380916182179_689.1pg The detectable warning is missing at the curb ramp Pedestrian Access RW.es Curb ramps shall have a detectable wammg that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Sidewalks-Finding 830331- 931 ADA Evaluation (PAM Sidewalks CommunnyOr A Curb Ramp Detectable Warnings Missing NA 003659 105.5012 sides 20 inch minimum m the direction of travel Open the full width of the the street crossing at the shared taw path 2011 PROMS R2081 COCR $350 WO 1/1/2033-1/1/2038 FindIng_6300916191I30891.0pg Approx es OOsq/h The shared p is not wide. g (Co adding an nice the shared use path is designed for two way travel,n is additional 2f)of concrete to the Pedestrian Access Roines continuous inuous clear width of pedestrian access routes shall be 10 oft minimum exclusive of the width of the recommended thatthe shared use path 0 at least 1011.de concrete shared use Path-F 930 ADA Evaluation (PAR) Shared Use Path Moraine Trail Continuous Width 120 minimum NA NA 4036760 •1055350 curb a Open Increase the widW of the shared use path 2011 PROWAG R3023 D25 $00,000 $66,000 1/1/2033-1/1/2038 path)g Finding_6380921959314_1011pg The detectable warning is missing at the curb ramp ■ I Pedestrian Access Rwttes Curb ramps shall have a detectable warning that extends the full width of the curb ramp excluding the flared Install an ADA compliant detectable warning surface that extends Shared Use Pad)-Finding 830300- 937 ADA Evaluation (PAR) Shared Use Pad) Moraine Trail Curb Pamp Detectable Warnings Missing NA 0036899 1055319 sides 20 inch minimum m the direction of travel Both sides Open the full width of the the street crossing at the shared use path 2011 PROW.0.2081 DSCR $700 $8001/1/2033-1/1/3038 Finding_63809319880393200pg The surface of We pedestrian access route is not firm stable and slip resistant Pedestrian Access Roues Firm Stable And Slip The surfaces of pedestrian access routes and elements and spaces along the pedestrian access route that are shared Use Path-Finding 830301• 938 ADA Evaluation (PAR) Shared Use Path Moraine Trail Surface Resistant NA NA 4036901 1055316 required to be accessible that connect to pedestrian access routes shall be firm stable and slip resistant Trails turns to gravel Open Need additional information to where this trail leadsm 2011 PROWAG R3027 D53 50 SO 1/1/2020-1/1/2027 Finding_6300921997305_466.1pg The shared use path is not wide enough III Pedestrian Access Routes The continuous dear width of pedestrian access routes shall be 10 oft minimum exclusive of the width of the Shared Use Pa.-Finding 830376- 939 ADA Evaluation (PAR) Shared Use Pad) Moraine Tun Continuous width 120 minimum NA NA 0036760 105,5354 curb a Open Refer to Record 930 for Reccomendatln and Pricing 2011 PROW.R302 3 ors 6- $- 1/1/xo33-1/1/2038 Finamg_63009219593141010pg The detectable warning is missing at the curb ramp Pedestnan Access RoMes Curb ramps shall have a detestable wammg that extends the full wrdth of the curb ramp excluding the flared InMall an ADA compliant detectable wamIng surface that extends Sidewalks-Finding 830345- 943 Am.-al.-Lion (PAR) Sidewalks Fourth St curb Ramp Detectable Warnings Missing NA 40 37321 .105 5057 sides 24 inch minimum m the direction of travel Open the full width of the curb nmp 2011 PROW.R208 1 OS-CR 5350 5400 1/1/2033-1/1/2038 Fin20g_6380922220233_902 Mg The detectable warning is missing at the curb ramp .1 Pedestnan Assess Routes Curb ramps shall have a detestable wammg that extends the full width of Me curb ramp excluding the flared InMall an ADA compliant detestable warning surface that extends Sidewalks-Frnding 830347- 945 ADA Evaluation (PAR) SidewalIG Fourth St Curb Ramp Detestable Warnings Missing NA . 1.0.37.36 -105 5053 sides 24 inch minimum m the direction of tmvel Open Me full width of the curb ramp 2011 PROWAG 8208 1 OS-CR $350 $400 1/1/2033-1/1/2038 FindIng_6380922.241409_734.1p3 The detestable warning is missing at Me curb ramp Pedestnan Access Routes Curb ramps shall have a detestable wammg that extends the full wrdth of the curb ramp excluding the flared InMall an ADA compliant detectable wamIng surface that extends Sidewalks-Finding 830349- 947 ADA Evaluation WAN) Sidewalks Fourth St Curb RamP Detectable Warnings Missing NA 40 37426 -CON 5048 sides 24inch minimum ill the direction of travel Open the full width of the curb ramp 2011 PROW.R208 1 OS-CR 8350 5400 1/1/2033-1/1/2038 Finding_6380922248559_632 mg 1.111 The detectable warning is missing at the curb ramp Pedestnan Access Routes Curb ramps shall have a detestable wammg that extends the full width of Me curb ramp excluding the flared InMall an ADA compliant detestable warning surface that eMends Sidewalks-Finding 830350- 948 ADA EvaluMion (PAR) SidewalIG Fourth St Curb Ramp Detestable Wamings Missing NA 40 37386 -105 505 sides 24 inch minimum in the direction of tmvel Open the full width of the curb ramp 2011 PROW.8208 1 OS-CR $380 $400 1/1/2033-1/1/2038 FindIng_6380922257167_866.ips The running slope of pedestrian access route exceeds the general grade of the adtacent street of highway Pedestrian Access Routes With.Street.'Hwy Where pedestrian access routes are contained within a street or highway right•of-way the grade of Remove and replace the existing walkway that has an excessive Sidewalks-Finding 830352- Sidewalks•Findrng 830352• 950 ADA Evaluation (PAR) SidewalIG Fourth St SlOPe-Running(Grade) ROW NA 40 37497 -105 5045 pedeStrian access routes shall not exceed the general grade established for the adtacent Street or highway 13 6096 Open running slope 2011 PROWAG R302 5 133.3 31,000 $1,500 1/1/2033-1/1/2038 5,20',100 ft Fincling_6380922296387_957 log Fl96,66-63.09z2287163_582 i06 Mil I The naming slope of the MR DA)ramp is excessive I Pedestnan Assess Routes The running slope of the curb mmp shall be 5 percent minimum and 8.3 percent magrnum but Mall not Reconstruct GA rarnp to provide a running slope grade less than 2011 PROW.R304 2 2 Sidewalks-Finding 830354- Sidewalks-Finding 830354- 952 ADA EvaluMion (PAR) Sidewallg Fourth St Curb Ramp %Give-Running(Wade) Parallel Ramp Left Ramp 40 37343 -105 5056 require Me ramp length to exceed 15.0 ft 11 DA Open or equal to 8 3% 2011 PROW.R304 3 2 D.2.CR 53,000 $3,500 1/1/2033-1/1/2038 FindIng_6380922311178_565.ips F1nding_6380922312541_837 tpg The pedestrian access route is not wide enough Approx 760LF 3,040..(Cost includes removal and Pedestnan Access Routes The continuous clear width of pedestrian access routes shall be 4 0 ft minimum exclusive of the width of the Remove and replace Me exisitng sidewalk.Install new sidewalk replacement of existing Sidewalks•Finding 830356• Sidewalks•Finding 830356• Sidewalks-Finding 830356• 954 ADA Evaluation (PAR) Sidewalks South Court Continuous.Width 48 Inches Minimum NA NA 40 37749 •105 5204 curb Open that is 411 wide 2011 PROWAG R302 3 132.3 $30,400 $45,600 1/1/2033-1/1/2038 sidewalk) Finding_6380922333228_768 ipg Finding_6380922333837_291 Mg Fmdi46_65808223368.-.,/99 The pedestrian assess route is not wide enough Approx 1,750LF 7,000sq/ft (Cost includes removal and Pedestnan Assess Routes The continuous clear width of pedestrian access routes shall 1.4.0 ft minimum occlusive of the width of Me Remove and replace the egsitng sidewalk.InMall new sidewalk replacer..of exiMing Sidewalk-Finding 830357. Sidewalk-Finding 830357- Sidewalk-Finding 830357. Sidewalk•Finding 830357- 955 ADA EvaluMion (PAR) Sidewalk Third St Continuous Width 48 Inches Minimum NA NA 40 37749 -105 5204 curb Open that is 4.ft wide 2011 PROW.R302 3 02.S $70,000 $105,000 1/1/2033-1/1/2038 sidewalk) F,5013S..6380922347660_110,pg .6,6380922348263_207 jpg FindIng_6380922303726_652,pg Findmg_6380922349849_478 ipg The pedeStron access route is not wide enough Approx 760LF 3,040..(Cost includes removal and Pedestnan Access Routes The continuous clear width of pedestrian access routes shall be 4 0 ft minimum exclusive of the width of the Remove and replace the exisitng sidewalk.Install new sidewalk replacement of existing Sidewalk-Finding 630358• Sidewalk•Finding 830358- AND ADA Evaluation (PAR) Sidewalk NoTh Couq Continuous Width 48 Inches Minimum NA NA 40 37448 .105 5.3 curb Open Mat rs rift wide 2011 PROWAG R302 3 62..S 545,600 $45,600 1/1/2027-1/1/2033 sidewalk) Fin441g_6380922360353_949 mg Findi7g_6380922361090_380 IPS The pedestrian assess route is not wide enough Approx 1,300LF 5,200sq/ft (Cost includes removal and Pedestnan Access Routes The continuous clear width,pedeMnan access routes shall 1.40 ft minimum e.lusive of the Imdth of the Remove and replace the exisitng sidewalk.Install new sidewalk replacer..of misting Sidewalk-Finding 830359. Sidewalk•Finding 830359- 957 ADA EvaluMion (PAR) Sidewalk Second St Continuous Width 48 Inches Minimum NA NA 40 37401 -105 5079 curb Open that is 4ft wide 2011 PROW.R302 3 02.5 $52,000 578,000 1/1/2033-1/1/2038 sidewalk) Fin2Ing_638092237876.3_973.105 Findmg_6380922379693_352 mg The Fwd.-Man assess route is not wide enough APProx 7601F 3,040m/ft(Cost imludes removal and Pedestnan Access RoMes The contrnuous clear width of pedestrian access routes shall be 4 0 ft minimum emlusive of the width of the Remove and replace the exIsItng sidewalk.Install new sidewalk replacement of existing Sidewalk-Finding 830360. ese am Evaluation (PAR) Sidewalk First St Continuous Width 48 Inches Minimum NA NA 40 37478 -105 5088 curb Open Mat is sift wide 2011 PROW.R302 3 D2, OARS® $45,600 1/1/2033-1/1/2038 sidewalk) Finding_6380922399092_92.3 mg Site Accessibility Evaluation On Street Parking and Transit Stops PU23-002206 170 MacGregor Ave Prepared By Estes Park, CO 80517 Public Right of Way MILE NIGH Inspection Date: 10/24/2023 ACCESSIBILITY CONSULTANTS Inspector: Ryan Kelley (719) 205 - 7753 Powered by&BIueDAG Table of Contents Findings 3 Transit Stops and On-Street Parking 3 Red Route 3 Gold Route 21 Silver Route 36 Brown Route 46 Blue Route 68 Macgregor Ave - On Street Parking 92 Park Lane - On Street Parking 99 W Elkhorn Ave - On Street Parking 103 Big Horn Dr- On Street Parking 106 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37624, -105.5244] Finding: 1 - #3 Ore Cart Rock Shop The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.25% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.25% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A A •-/- al- Mile High Accessibility 3 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 1 Additional Finding Photos • pp 4 ti _ • R _ 1♦ • • )1a:r Mile High Accessibility 4 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37636, -105.5243] Finding: 2 - #3 Ore Cart Rock Shop Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 8'x5' Budgeting Range: R308.1.1.1 $0 - $0.00 Recommendation: N/A- Refer to Finding Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A 60"min 4\ !1- E ? rn curb or vehicle roadway edge l + , A, , _ BUS-2112 Mile High Accessibility 5 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 2 Additional Finding Photos )l� at PO : .I iiiiiik , .- ; - Mile High Accessibility 6 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.3764, -105.5268] Finding: 3 - #4 Tregent Park The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.1% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Mile High Accessibility 7 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 3 Additional Finding Photos -.-- `!"4, �.�lf, .. 1 ''. •: } tr itorkASUC • ‘-ira• , %. `..- .,447. `t:' aV` � `t ea •,.. Mile High Accessibility 8 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37642, -105.5295] Finding: 4 - #5 West Park Center The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Damaged asphalt with excessive Budgeting Range: slopes of 4.8% $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A s r ft • r„ � 'ft Mile High Accessibility 9 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 4 Additional Finding Photos W.' 1li +1k 7: !T !AIeir $ A 1 ♦milt •70.`'I 40 r I,,, IP,:t:k. „c ilVt- 7 4C:fP:-:',. r� a1 . a1< it. Mile High Accessibility 10 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.3786, -105.5335] Finding: 5 - #6 West of Maxwell Inn The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Gravel with 11.55% slope Budgeting Range: $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A • Mile High Accessibility 11 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 5 Additional Finding Photos .4 1 , 4. .. • -- '',}4.1�.+5 R+'!�'. `" ~-.1 ;• n`--ems`._ i ii,.• I il ¢tom r •, '_,,% ,,,, "'IE.*, -4 c . s • Att itt. i — sp • �' 'c w11til,. ,� `tea w i'•. 11.. '' ,.2 1 Mile High Accessibility 12 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.3762, -105.528] Finding: 6 - #7 Mrs Walshs Garden The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 90" Budgeting Range: R308.1.1.1 $500 - $800.00 Recommendation: Increase the length of the boarding and alighting area to 8' minimum. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A s j 60"min r f so '' :) fir / C_ �o curb or vehicle t 4 1 roadway edge l jot - -= BUS 2112 k II .. Mile High Accessibility 13 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 6 Additional Finding Photos AO r 4. • Mile High Accessibility 14 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37624, -105.5281] Finding: 7 - #7 Mrs Walshs Garden The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.7% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.7% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A 4 1t 4,' ., , .PIS , _ pi \\',167. Mile High Accessibility 15 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 7 Additional Finding Photos _• • • • • • I • •• • _• - �„ ti ~• r• Mile High Accessibility 16 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37612, -105.5246] Finding: 8 - #8 Grubsteak The transit stop contains changes level greater than 1/2 inch. Vertical surface discontinuities shall be 1/2 inch maximum. Vertical surface discontinuities between 1/4 inch and 1/2 inch shall be beveled with a slope not steeper than 50 percent. The bevel shall be applied across the entire vertical surface discontinuity. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 1" at curb Budgeting Range: R302.7.2, R308.1.3.1 $250 - $500.00 Recommendation: Remove and regrade the pavers at the boarding and alighting area of the transit stop to eliminate the vertical surface discontinuity. Barrier Priority: Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Estimated Remediation Date: 01/01/2025 Notes: [11/03/2023] Regrade pavers _ . r� 1;q.. 1;-1..to 1;2 max 411 . ___ ,1 Ji rad i , ,..,.., I .f 1 1ft -I Mile High Accessibility 17 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 8 Additional Finding Photos Iliiir,..,.iiitlif: 7, 1;74. I',r . Mile High Accessibility 18 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Red Route Lat/Long: [40.37727, -105.5184] Finding: 9 - #10 Thirty Below Leather The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 10.5% at pavers Budgeting Range: R308.1.1.2 $250 - $500.00 Recommendation: Remove and regrade the pavers at the boarding and alighting area of the transit stop to eliminate the excessive cross slope. Barrier Priority: Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Estimated Remediation Date: 01/01/2025 Notes: N/A ,, _ 'CS Ir N.Iii .416 Mile High Accessibility 19 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 9 Additional Finding Photos / - • IAMB Mile High Accessibility 20 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.37749, -105.5204] Finding: 10 - #2 The Aspire at Steamer Pkwy The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 OxO Budgeting Range: $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A Mile High Accessibility 21 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 10 Additional Finding Photos Mile High Accessibility 22 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.38197, -105.5167] Finding: 11 - #2 The Aspire at Steamer Pkwy The pedestrian access route is missing between the boarding and alighting area or boarding platform and the street, sidewalk, or pedestrian circulation path. Boarding and alighting areas and boarding platforms shall be connected to streets, sidewalks, or pedestrian circulation paths by pedestrian access routes. Boarding platforms shall not exceed a slope of 2 percent in any direction. Where boarding platforms serve vehicles operating on existing track or existing street or highway, the slope of the platform parallel to the track or the street or highway is permitted to be equal to the grade of the track or street or highway. Citation: As Built: Conceptual Cost/ Budgeting Range: 2011 PROWAG Section: Not connected to right of way R308.1.3.2 $3,500 - $5,000.00 Recommendation: Connect the transit stop to the public right of way. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Mile High Accessibility 23 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 11 (Continued) bus • - shelter boarding • el' and alighting area pedesVian curb or vehicle roadway l pn4 accessible route edge 1 Lr Y of BUS 2112 Witir-4.3 -..„,„4,44.... A Mile High Accessibility 24 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 11 Additional Finding Photos .+sue-+�— =r - Mile High Accessibility 25 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.39089, -105.5619] Finding: 12 - #3 Timber Creek Chalets The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 1.7% in driveway, adjacent area Budgeting Range: is gravel $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A • • ' Y4 's:.: 1 IMP �i pp} Mile High Accessibility 26 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 12 Additional Finding Photos "a : 17;-em . ad K. w Li { T+rrR4�M • - -Add lift y 1 -is v 7.1 t ' .; sati:N -« Mile High Accessibility 27 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.39956, -105.5748] Finding: 13 - #4 McGregor Mtn Lodge The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 8x5 in driveway, gravel adjacent Budgeting Range: to driveway $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A • 1 - T t Mile High Accessibility 28 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 13 Additional Finding Photos 1111,111111111111111111111. iiiiitit. • ,.• ,e4•Naii:!-(:4 ' ..4 , . ' e• . A via Mile High Accessibility 29 of 108 Consultants, Inc. Powered by LkBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.40203, -105.5866] Finding: 14 - #5 Fall River Vistor Center The transit stop contains changes level greater than 1/2 inch. Vertical surface discontinuities shall be 1/2 inch maximum. Vertical surface discontinuities between 1/4 inch and 1/2 inch shall be beveled with a slope not steeper than 50 percent. The bevel shall be applied across the entire vertical surface discontinuity. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 1" Budgeting Range: R302.7.2, R308.1.3.1 $75 - $150.00 Recommendation: Grind down the concrete to eliminate the tripping hazard. Barrier Priority: Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Estimated Remediation Date: 01/01/2025 Notes: N/A 41, 4 .v t ,°r 1 4 to 1;2 max 1 r;1.. t • ----»- -- • Mile High Accessibility 30 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.39505, -105.5644] Finding: 15 - #6 Estes Park Condos The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Gravel Budgeting Range: $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A • • Mile High Accessibility 31 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.38968, -105.5612] Finding: 16 - #7 Aspen Winds The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 8.3% on gravel Budgeting Range: $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A w�• ;• • 41111, r1 a - • Mile High Accessibility 32 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 16 Additional Finding Photos ' ►yeti! rCu�•,, 4, • +?a! '!z .�.4�:r+; , 'tiro" . .... •P . t.7.,‘ / ''',1.•. :4' I . ,t, ia � 44.,..1,*31;i0.f 7 ..,..7..„,•„fi 4 .5 s4 i t:.,,,e:A. 3;,;,r.%4.- ).,10 'F 4 f '''s.rrk"!?4;Zok,..t-Wt 1; :4 4, Mile High Accessibility 33 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Gold Route Lat/Long: [40.38402, -105.5474] Finding: 17 - #10 The Wapiti The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.2% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A "0 ,111146 Mile High Accessibility 34 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 17 Additional Finding Photos L• .-I • c O Z' ' i i .a -• ^'fir. • {- A ll ror4 ' • '...iiiiiikAalL104.-:--r Ze, ..- .J1 ,. is ...rw .. , . _ _ _, . .. ,_ , _ . . _. i 411 riiiill...-- • . _ ... • , , .\ - , ... ,..„, . . Mile High Accessibility 35 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Silver Route Lat/Long: [40.37215, -105.5151] Finding: 18 - #3 EP Health The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 16.45% boarding located at curb Budgeting Range: R308.1.1.2 ramp $800 - $1,200.00 Recommendation: The transit stop is located at a curb ramp. Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Mile High Accessibility 36 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 18 (Continued) I I • Mile High Accessibility 37 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 18 Additional Finding Photos "X IIIIIIIII • �:. y =v; �`;;i.. Mile High Accessibility 38 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Silver Route Lat/Long: [40.37039, -105.5061] Finding: 19 - #4 Ziggis Coffee The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 64" Budgeting Range: R308.1.1.1 $500 - $800.00 Recommendation: Increase the length of the boarding and alighting area to 8' minimum. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A 60"min ,f - :. .. r rT"... r �f� C E rn curb or vehicle . #► ti roadway edge ..111111 BUS 2112 Mile High Accessibility 39 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 19 Additional Finding Photos 111044 r ... 11 al.i ' • Y.N IP• Mile High Accessibility 40 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Silver Route Lat/Long: [40.36823, -105.4928] Finding: 20 - #6 Solitude Cabins The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 6' due to parking stall. Need to Budgeting Range: R308.1.1.1 block off 2 stalls to provide $200 - $300.00 access to the facility and ramp. Recommendation: Install angled striping at the 2 parking stalls to prevent people from parking in them. Barrier Priority: Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Estimated Remediation Date: 01/01/2025 Notes: N/A 60"min "'M quit, 6,�' -� �hr -ems ' a.- 9 _ --^ c _ • = : curb or vehicle roadway edge J r BUS-2112 Mile High Accessibility 41 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 20 Additional Finding Photos - � .11 -3 lit - ' jrli -. ‘'..' - ---- * • l' ;, ":A '11F- ._ 1111.1 . ' ' .I. ' I" lir .7- 1111111111, Mile High Accessibility 42 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Silver Route Lat/Long: [40.36823, -105.4928] Finding: 21 - #6 Solitude Cabins The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 6.95% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Ilmorw I. 1:11; Jo i ■ • Mile High Accessibility 43 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 21 Additional Finding Photos ,t s. • • . , ' • l £I • • . • / • Mile High Accessibility 44 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Silver Route Lat/Long: [40.36935, -105.4991] Finding: 22 - #7 EV Community Center The transit stop contains changes level between 1/4 inch and 1/2 inch that are not beveled. Vertical surface discontinuities shall be 1/2 inch maximum. Vertical surface discontinuities between 1/4 inch and 1/2 inch shall be beveled with a slope not steeper than 50 percent. The bevel shall be applied across the entire vertical surface discontinuity. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 1" Budgeting Range: R302.7.2, R308.1.3.1 $75 - $150.00 Recommendation: Grind down the concrete to eliminate the tripping hazard. Barrier Priority: Priority 1 — High: Should be completed within 12 months. Includes findings that have little or no cost, were in violation of the codes at the time of construction, pose an imminent safety threat, or would remove barriers to the greatest number of people to the Town's programs and services. Estimated Remediation Date: 01/01/2025 Notes: N/A ' " -- _ 1q.. 1,4 to 1;2-max y. 421 Mile High Accessibility 45 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.37478, -105.5218] Finding: 23 - #2 East Riverside and Rockwell Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: Under construction Budgeting Range: R308.1.1.1 $0 - $0.00 Recommendation: N/A- Refer to Finding Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A Pilliiiiii.... 1 60"min I curb or vehicle roadway edge ICI BUS-21 12 t ill Mile High Accessibility 46 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 23 Additional Finding Photos , _ Mile High Accessibility 47 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.37749, -105.5204] Finding: 24 - #3 Estes Park Brewery/Fun City The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: Under Construction Budgeting Range: R308.1.1.1 $0 - $0.00 Recommendation: N/A- Refer to Finding Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A t 60"min .06.64.040 curb or vehicle roadway edge _ • u T it r r Atir BUS 2112 Mile High Accessibility 48 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.36639, -105.5375] Finding: 25 - #4 Worldmark The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.95% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.95% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A Mile High Accessibility 49 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 25 Additional Finding Photos ��* .• ' • irt'4,400 . • • t, • . 'It 4S • 1. ' 1�i• I •4.! 1 • ; ".i. " ....c' 't v 1 ,1W. t,i,$' : .M. :J,i.4ih'y3l„ Mile High Accessibility 50 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.36152, -105.538] Finding: 26 - #5 Manor RV The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 0" Budgeting Range: R308.1.1.1 $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A 60 min * ; r it t,...-=. .• , _ o - rn curb or vehicle swi roadway edge L jg + I r t -' � BUS-2112 Mile High Accessibility 51 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 26 Additional Finding Photos 1 • W. - i - - �4 —. MANOR r1 R/V Aum 41141144, !Palk h Mile High Accessibility 52 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.36357, -105.5437] Finding: 27 - #6 National Park Village Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 5.9% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A �a ' i:Iii.-161Z:-:1' -4444 4 , r Mile High Accessibility 53 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 27 Additional Finding Photos goit r. • ::.=- SYt Yam. fi La... -•-.. 1111111111 I Mile High Accessibility 54 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.36407, -105.5458] Finding: 28 - #7 Alpine Trail Ridge Inn The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 4.85% uneven asphalt Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A A ,4441 3 i N .,...,.__.3t _..M..r...e. %Ili:•;i 0.*1111 Mile High Accessibility 55 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 28 Additional Finding Photos ' 3c , .A. kt,,,',A . .-'1'.4 i ';,,,. • + J i .4 ` ' ' •/� r•. • I Y Mile High Accessibility 56 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.36205, -105.553] Finding: 29 - #8 Elk Meadow RV The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.4% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A • Mile High Accessibility 57 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 29 Additional Finding Photos _, ., „,..,A,A t-? C.'•S r a mow— l 4 - - mil i t t'..,, •. .1 . • A k„ ,..,, •. . ,.. , r ,� ,_ I . . .. .01011. ..K�, „,' ;AN'.• 'r,, .6 1 :,i ...sr ''•',',,,••44•1 'r, •,.it l't "14k4k.o.4. ., 4. . .: , , ,..., dr" Mile High Accessibility 58 of 108 Consultants, Inc. Powered by cdik B1ueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.34948, -105.568] Finding: 30 - #10 Swiftcurrent Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2%, uneven and damaged Budgeting Range: R308.1.1.2 asphalt $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A y i Alb Mile High Accessibility 59 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 30 Additional Finding Photos 9 :`.',ice. , 'd 'y, . • -..' :N, 3 ...s,'+ _ . -.. . _. , •`• ',•lam :, .. ! �_-.'.. - -). ,i• • ' il Y'vu r . .. . • 1 •.I L - � . • - . • * A.• caw X r' , I Mile High Accessibility 60 of 108 Consultants, Inc. Powered by GR.BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.34024, -105.5728] Finding: 31 - #11 YMCA Admin The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.65% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A -7 ,,; Yr_y ,i�' .ice'. 34 ;. ,.' Oar S \ \rillillk Mile High Accessibility 61 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 31 Additional Finding Photos ; APPr -11,1 I - ,r • Mile High Accessibility 62 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.35418, -105.5623] Finding: 32 - #12 Glacier Lodge The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 6.1% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A • Glacijodge Mile High Accessibility 63 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 32 Additional Finding Photos -+: Fx ,.• • r r- r� yS_ r _ , � . � . - 44 -.-n- yl,...N 41-4 , ..eipj.„Ar„ ' ` ' .•fit ilik j l ,..tom �' .—Pk "T •s'_ �...._,.�.yw*tj y iwr ti•.l r Mile High Accessibility 64 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.35838, -105.5569] Finding: 33 - #13 Rockmount Cottages The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 6.35% in driveway adjacent area Budgeting Range: is gravel $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A 'ohNljoill Mile High Accessibility 65 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 33 Additional Finding Photos ' t' �'i . 'l. :' •Ate. :. ;!:, ?J .:Yc•... ., ' '• •�°` ' .- r -t •=.fit.•• � •�. •i .N ,,::, .4. , M A, .f • 1. t 1)4 a Mile High Accessibility 66 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Brown Route Lat/Long: [40.37749, -105.5204] Finding: 34 - #14 East Riverside and Rockwell The length of the boarding and alighting area is less than 8 feet. Boarding and alighting areas shall provide a clear length of 8 feet minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 5 feet minimum, measured parallel to the street or highway. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: Under construction Budgeting Range: R308.1.1.1 $0 - $0.00 Recommendation: N/A- Refer to Finding Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A 60"min F 1- E curb or vehicle l roadway edge T i i r BUS 2112 Mile High Accessibility 67 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.37749, -105.5204] Finding: 35 - #1 Visitor Center for all routes The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.75% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.75% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A 4 c r Mile High Accessibility 68 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 35 Additional Finding Photos CAN 1101,110.Pimpip -vor, ' Mile High Accessibility 69 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38255, -105.4981] Finding: 36 - #4 Quality Inn The transit stop contains horizontal openings greater than 1/2 inch. Horizontal openings in gratings and joints shall not permit passage of a sphere more than 1/2 inch in diameter. Elongated openings in gratings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: Multiple openings Budgeting Range: R302.7.3, R308.1.3.1 $800 - $1,200.00 Recommendation: Regrade the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A A • Mile High Accessibility 70 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 36 Additional Finding Photos « , ~ 11W 4, J r. r Y :F 7 �iT .1.s.. •--ti tea. . 404, KS.* ,. 'r r'YJ' r 1.'x. ' iTit''''1. l r t PiXi s;r to / i. .t '� Mile High Accessibility 71 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38144, -105.4955] Finding: 37 - #5 Antonio's Pizza The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 4% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A S - • 4 Nnrn- . I If. Mile High Accessibility 72 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 37 Additional Finding Photos ► i '' ASS •••r''-1, , t 4 .v.ty....,4%,r. . -, Az... 4. , .. t,�L.-T:1 . , f ?.,,,,..),. i, %.,t, ..;.1.1„ AI, .'_Z,-i s::\` r,11 1• -- �fyi. 4... t -....ii / i. th' .lam. 1 '_ Tip 'S 14.l:04A"e ?'-: 1 ' +,•.in0 Mile High Accessibility 73 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.37872, -105.4922] Finding: 38 - #6 Estes Park Marina The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Loose gravel Budgeting Range: $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A VFITI NO PARKING Fr Mile High Accessibility 74 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 38 Additional Finding Photos '" l � - Mile High Accessibility 75 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.37785, -105.487] Finding: 39 - #7 KOA The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.35% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.35% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A K � L ! 'ter .r .. . Mile High Accessibility 76 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 39 Additional Finding Photos 4y3.7.4. Wi .4Se - •, „ ' f, ,4.io•Art• e,k,4 ,+ . ,, - • • f'4•!`1•"`•.,V., . -•..r.- Iri,T 41"1:ity, 'Z:3%7( 0 • '' l'c v1::;..„. 1,•� �,- :1: lt. fr"l Mile High Accessibility 77 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.39116, -105.4904] Finding: 40 - #8 Good Samaritan Village The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 2.35% Budgeting Range: R308.1.1.2 $0 - $0.00 Recommendation: It is our opinion that the 2.35% cross slopes falls within conventional construction tolerance. No action required. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A Sz o r Mile High Accessibility 78 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 40 Additional Finding Photos 3 , •• OMNI Mile High Accessibility 79 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.39005, -105.4931] Finding: 41 - #9 Talons Point Apartments The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.65% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: [10/24/2023] Depends where the bust stops 404014 Y. Mile High Accessibility 80 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 41 Additional Finding Photos plc r...k.,....s ' w.r � aft?IL • t j j 1111,410111.911171111 . '`' ,� • opi tr 1� L - w • [[0-4 44,111010 61 • ry A Mile High Accessibility 81 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38898, -105.4894] Finding: 42 - #10 Salud Medical Health Center The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 9% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: [10/24/2023] Angled at curb 44 4lit I Mile High Accessibility 82 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 42 Additional Finding Photos . 1111/ A - i ' .. IIN it7r itio=.#..e..4,1 1111• :_.,..4vio.-4,'' .'r•r'l.r.og 4. . .. .7_,.„1,4,..... , _ ... ., .. _......„Nst45 . ..:,,,--.:71.,.-4-7....,, • . . .. . :i.• • . 41:17: 4' Mile High Accessibility 83 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38755, -105.4926] Finding: 43 - #11 Crossroads Ministry The slope of the boarding or alighting area is greater than 2%. Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable. Perpendicular to the street or highway, the grade of boarding and alighting areas shall not be steeper than 2 percent. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: 3.4% Budgeting Range: R308.1.1.2 $800 - $1,200.00 Recommendation: Regrade the walkway where the boarding and alighting area is located for the transit stop. The slope perpendicular to the street cannot exceed 2.1%. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A 4 - i Mile High Accessibility 84 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 43 Additional Finding Photos "I'll" • Mile High Accessibility 85 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38282, -105.4939] Finding: 44 - #13 Raven Ave and Lone Pine Dr The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 5.65% at street, adjacent surface Budgeting Range: is grass $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A kt d" -.57 \ _ _r• _ _ „ ,_ iiionsti n i , Mile High Accessibility 86 of 108 Consultants, Inc. Powered by L�BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 44 Additional Finding Photos • 10 k•t. , • • . $ .,r Mile High Accessibility 87 of 108 Consultants, Inc. Powered by Ld,BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.38291, -105.4981] Finding: 45 - #14 Lakefront at Ranch Meadow The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Ox0, bust stop located in turning Budgeting Range: lane $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A r i .a- a Mile High Accessibility 88 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 45 Additional Finding Photos ,s S .trY"t ,),. Mile High Accessibility 89 of 108 Consultants, Inc. Powered by a BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Blue Route Lat/Long: [40.37984, -105.5153] Finding: 46 - #15 Lower Stanley Village The surface of the boarding and alighting area for the transit stop is not firm, stable and slip resistant. The surfaces of boarding and alighting area and elements and spaces along the pedestrian access route that are required to be accessible that connect to pedestrian access routes shall be firm, stable, and slip resistant. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R302.7 Ox0 bus stop in drive lane or on Budgeting Range: grass. $750 - $1,000.00 Recommendation: Install a boarding and alighting area at the transit stop that is a minimum of 8'x5'. We recommend installing concrete for the boarding and alighting area. Ensure the slope that is perpendicular to the street does not exceed 2.1 Barrier Priority: Priority 2— Important: Should be completed within 24 months. Includes barriers that have a lower budgetary impact on the entity in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities. Estimated Remediation Date: 01/01/2026 Notes: N/A Mile High Accessibility 90 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 46 Additional Finding Photos : .''. IP:--.. - - • ,-4; is.i6 ajar oer I ' : i - MR& It $ _ k r i - j I Mile High Accessibility 91 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Macgregor Ave - On Street Parking Lat/Long: [40.37997, -105.5221] Finding: 47 There are no on-street accessible parking stalls. Where on-street parking is provided on the block perimeter and the parking is marked or metered, accessible parking spaces shall be provided. There is a total of 84 marked or metered parking stalls on the block perimeter. There should be a minimum of 4 accessible stalls designed as van accessible. Advisory R214 On-Street Parking Spaces. The MUTCD contains provisions for marking on-street parking spaces (see Section 3B.19). Metered parking includes parking metered by parking pay stations. Where parking on part of the block perimeter is altered, the minimum number of accessible parking spaces required is based on the total number of marked or metered parking spaces on the block perimeter. Citation: As Built: Conceptual Cost/ Budgeting Range: 2011 PROWAG Section: R214 0 ADA on-street parking stalls $10,000 - $15,000.00 Recommendation: 4 angled ADA on street parking stalls need to be provided on Macgregor Ave. We recommend dispersing the ADA parking stalls throughout the street to provide the most access to services provided by the Town. Each angled ADA parking stall will need to be a minimum of 132" with a 60" access aisle located on the passenger side of the parking stall. A curb ramp will need to be installed at the head of each access aisle and connect to the pedestrian access route. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Mile High Accessibility 92 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 47 (Continued) Table R214 On-Street Parking Spaces . Total Number of Marked or Metered Minimum Required Number of Parking Spaces on the Block Perimeter Accessible Parking Spaces 1 to 25 2610 50 2 116. 511075 3 761.2 100 4 101 to150 5 151 10200 6 201 end aver 4 percent of total Mile High Accessibility 93 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 47 Additional Finding Photos t ,0731n . r Mile High Accessibility 94 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Macgregor Ave - On Street Parking Lat/Long: [40.38015, -105.5221] Finding: 48 Where perpendicular or angled parking is provided, an access aisle 8 feet wide minimum shall be provided at street level the full length of the parking space and shall connect to a pedestrian access route. The access aisle shall comply and shall be marked so as to discourage parking in the access aisle. Two parking spaces are permitted to share a common access aisle. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R309.3 N/A Budgeting Range: $0 - $0.00 Recommendation: This is one of the locations we recommend converting to an accessible angled parking stall. Refer to Record #94 for recommendations and pricing. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A k'__,,,,_:74_-;:iiii. - .- Y311' - . 'Ar \:_.. i — *1 1 ------------ soft Mile High Accessibility 95 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Macgregor Ave - On Street Parking Lat/Long: [40.37749, -105.5204] Finding: 49 The access aisle does not connect to the pedestrian access route. Where perpendicular or angled parking is provided, an access aisle 8 feet wide minimum shall be provided at street level the full length of the parking space and shall connect to a pedestrian access route. The access aisle shall comply and shall be marked so as to discourage parking in the access aisle. Two parking spaces are permitted to share a common access aisle. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R309.3 N/A Budgeting Range: $0 - $0.00 Recommendation: This is one of the locations we recommend converting to an accessible angled parking stall. Refer to Record #94 for recommendations and pricing. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A 1 80 ft Mile High Accessibility 96 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Macgregor Ave - On Street Parking Lat/Long: [40.37798, -105.521] Finding: 50 The access aisle does not connect to the pedestrian access route. Where perpendicular or angled parking is provided, an access aisle 8 feet wide minimum shall be provided at street level the full length of the parking space and shall connect to a pedestrian access route. The access aisle shall comply and shall be marked so as to discourage parking in the access aisle. Two parking spaces are permitted to share a common access aisle. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R309.3 N/A Budgeting Range: $0 - $0.00 Recommendation: This is one of the locations we recommend converting to an accessible angled parking stall. Refer to Record #94 for recommendations and pricing. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A i r 4. 8.0fl Mile High Accessibility 97 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 50 Additional Finding Photos '11 ,, lik • a• 4110)04 • imp ; • ...• . t _ • • ti Mile High Accessibility 98 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Park Lane - On Street Parking Lat/Long: [40.37724, -105.5219] Finding: 51 There are not enough on-street accessible parking stalls. Where on-street parking is provided on the block perimeter and the parking is marked or metered, accessible parking spaces shall be provided. There is a total of 38 marked or metered parking stalls on the block perimeter. There should be a minimum of 2 accessible stalls designed as van accessible. Advisory R214 On-Street Parking Spaces. The MUTCD contains provisions for marking on-street parking spaces (see Section 3B.19). Metered parking includes parking metered by parking pay stations. Where parking on part of the block perimeter is altered, the minimum number of accessible parking spaces required is based on the total number of marked or metered parking spaces on the block perimeter. Citation: As Built: Conceptual Cost/ Budgeting Range: 2011 PROWAG Section: R214 There is 1 on-street accessible parking stall. There needs to be $2,500 - $3,750.00 1 more accessible parking stall on this street. Recommendation: 1 additional angled ADA on street parking stall needs to be provided on Park Lane. We recommend dispersing the ADA parking stalls throughout the street to provide the most access to services provided by the Town. Each angled ADA parking stall will need to be a minimum of 132" with a 60" access aisle located on the passenger side of the parking stall. A curb ramp will need to be installed at the head of each access aisle and connect to the pedestrian access route. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Estimated Remediation Date: 01/01/2027 Notes: N/A Mile High Accessibility 99 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 51 (Continued) IllTable R214 On Street Parking Spaces Total Number of Marked or Metered Minimum Required Number of Parking Spaces on the Block Perimeter Accessible Parking Spaces t to 25 26to50 51 to 75 3 7131.2 100 4 101k150 5 151 lb 200 8 ZOt end over 4 percent of total 1* Th i i cr .as 1111111 t1.: Mile High Accessibility 100 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Park Lane - On Street Parking Lat/Long: [40.37749, -105.5204] Finding: 52 Where perpendicular or angled parking is provided, an access aisle 8 feet wide minimum shall be provided at street level the full length of the parking space and shall connect to a pedestrian access route. The access aisle shall comply and shall be marked so as to discourage parking in the access aisle. Two parking spaces are permitted to share a common access aisle. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R309.3 Yes Budgeting Range: $0 - $0.00 Recommendation: This is the location we recommend converting to an accessible angled parking stall. Refer to Record #98 for recommendations and pricing. Barrier Priority: N/A Estimated Remediation Date: N/A Notes: N/A o- r Itia. ;1,1; rst • o 80ft J Mile High Accessibility 101 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 52 Additional Finding Photos Mile High Accessibility 102 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: W Elkhorn Ave - On Street Parking Lat/Long: [40.37618, -105.5255] Finding: 53 There are not enough on-street accessible parking stalls. Where on-street parking is provided on the block perimeter and the parking is marked or metered, accessible parking spaces shall be provided. There is a total of 11 marked or metered parking stalls on the block perimeter. There should be a minimum of 1 accessible stalls designed as van accessible. Advisory R214 On-Street Parking Spaces. The MUTCD contains provisions for marking on-street parking spaces (see Section 3B.19). Metered parking includes parking metered by parking pay stations. Where parking on part of the block perimeter is altered, the minimum number of accessible parking spaces required is based on the total number of marked or metered parking spaces on the block perimeter. Parallel on-street parking spaces shall be 24 feet (7.3 m) long minimum and 13 feet (4.0 m) wide minimum. Parallel on-street parking spaces shall not encroach on the traveled way. EXCEPTIONS: 1. Where parallel on-street parking spaces are altered but the adjacent pedestrian circulation path is not, any accessible parallel on-street parking spaces provided may have the same dimensions as the adjacent parallel on-street parking spaces if they are provided nearest the crosswalk at the end of the block face or nearest a midblock crosswalk, and a curb ramp or blended transition is provided serving the crosswalk. 2. In alterations, where providing parallel on-street parking spaces with the dimensions specified in R310.2.1 would result in an available right-of-way width less than or equal to 9 feet (2.7 m), measured from the curb line to the right-of-way line, the accessible parallel on-street parking spaces may have the same dimensions as the adjacent parallel on-street parking spaces if they are provided nearest the crosswalk at the end of the block face or nearest a midblock crosswalk, and a curb ramp or blended transition is provided serving the crosswalk. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R214 1 accessible on street parking Budgeting Range: stall is needed $4,500 -$6,000.00 Recommendation: 1 parallel ADA on street parking stall needs to be provided on W. Elkhorn Ave. The accessible parallel parking stall will need be a minimum of 24' long and 13' wide.. A curb ramp will need to be installed and connect to the pedestrian access route. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Mile High Accessibility 103 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Estimated Remediation Date: 01/01/2027 Notes: N/A fi" r 5L4 + , n'-1y li ( G-- Table R31<On-Street Parking Spaces F al k�� s r -s-//'i1 Total Number of Marked or Meteretl Minimum Bewared Number of '',� F�1 F ,, � �` # � { "� f Parking Spaces on the Block Perimeter Accessible Parking Spaces 11 A. .'' •i ' i r. .-, yi,,t,{�ti �'es _ 1 to25 I `?.,, x �_ ..1U1.$ 01, 4 26 to 50 2 T 1. 'i.l� b 4 _ - 1.4 . r 5163 75 S .�� 6 . rj 76 to 100 4 101 to 150 5 -- - 151 to200 6 201 antl over 4 percent of total Mile High Accessibility 104 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 53 Additional Finding Photos Y 1„ - ' A.. ,7,k„'' :,:i j r. . E • . •f I Ili A II ...... 1117. iii #4),it i' y + f .' ` 1 pir ' A 0. • Mile High Accessibility 105 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Transit Stops and On-Street Parking: Big Horn Dr - On Street Parking Lat/Long: [40.37684, -105.5242] Finding: 54 There are no on-street accessible parking stalls. Where on-street parking is provided on the block perimeter and the parking is marked or metered, accessible parking spaces shall be provided. There is a total of 30 marked or metered parking stalls on the block perimeter. There should be a minimum of 2 accessible stalls designed as van accessible. Advisory R214 On-Street Parking Spaces. The MUTCD contains provisions for marking on-street parking spaces (see Section 3B.19). Metered parking includes parking metered by parking pay stations. Where parking on part of the block perimeter is altered, the minimum number of accessible parking spaces required is based on the total number of marked or metered parking spaces on the block perimeter. Parallel on-street parking spaces shall be 24 feet (7.3 m) long minimum and 13 feet (4.0 m) wide minimum. Parallel on-street parking spaces shall not encroach on the traveled way. EXCEPTIONS: 1. Where parallel on-street parking spaces are altered but the adjacent pedestrian circulation path is not, any accessible parallel on-street parking spaces provided may have the same dimensions as the adjacent parallel on-street parking spaces if they are provided nearest the crosswalk at the end of the block face or nearest a midblock crosswalk, and a curb ramp or blended transition is provided serving the crosswalk. 2. In alterations, where providing parallel on-street parking spaces with the dimensions specified in R310.2.1 would result in an available right-of-way width less than or equal to 9 feet (2.7 m), measured from the curb line to the right-of-way line, the accessible parallel on-street parking spaces may have the same dimensions as the adjacent parallel on-street parking spaces if they are provided nearest the crosswalk at the end of the block face or nearest a midblock crosswalk, and a curb ramp or blended transition is provided serving the crosswalk. Citation: As Built: Conceptual Cost/ 2011 PROWAG Section: R214 1 accessible on street parking Budgeting Range: stall is needed $4,500 -$6,000.00 Recommendation: 1 parallel ADA on street parking stall needs to be provided on Big Horn Dr. The accessible parallel parking stall will need be a minimum of 24' long and 13' wide.. A curb ramp will need to be installed and connect to the pedestrian access route. Barrier Priority: Priority 3 — Moderate: Should be completed within 36 months due to a technical violation that is difficult and costly to re-mediate. Includes findings that create a moderate impact on accessibility compared to the cost of the remediation. Mile High Accessibility 106 of 108 Consultants, Inc. Powered by&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Estimated Remediation Date: 01/01/2027 Notes: N/A Table R214 On-Street Parking Spaces Total Number of Marked or Metered Minimum Required Number of Parking Spaces on the Block Perimeter Accessible Parking Spaces 1 to 25 t 26 to50 2 51 to 75 S 76 to 100 4 101 to 150 5 151 to 200 6 /. i9 201 anct over 4 percent of total ht 7.4 • IA i • Mile High Accessibility 107 of 108 Consultants, Inc. Powered by L&BIueDAG (719) 205- 7753 On Street Parking and Transit Stops - 170 MacGregor Ave Estes Park, CO 80517 Finding: 54 Additional Finding Photos Mile High Accessibility 108 of 108 Consultants, Inc. Powered by aBIueDAG (719) 205- 7753 Town of Estes Park ADA Self-evaluation and Transition Plan January 23, 2024 STESEP PAR F/lLEIIGII ACCESSIBILITY CONSULTANTS Presentation Outline • ADA Title II Requirements • ADA Transition Plan Requirements • Project Scope • Self-evaluation Overview • Facility Snmmary--RepQrts------------ • Public Right-of-w == ports • Next Stepp ADA Title II Requirements • Develop an ADA grievance procedure • Designate an ADA Coordinator to oversee Title II compliance • Make ADA Coordinator's name and number availableo public • Perform and retain a self-evaluation for 3 years • Develop a Transition-Plan-for structural c i -----_ MornTt1repuh1kIf1the ri hts and pro ' .ins under the ADA ---------- __--- • Seek public input on the draft Transilion Plan Public Outreach • Public input is essential for the Self-evaluation and Transition Plan process. • The ADA regulation requires that state and local government provide an opportunity for people with disabilities, and interested individuals or organizations, to review and nt on the self-evaluation and transition plan. This allows for peoplewith ddisabilities and organizations contribute to theprocess of-gener-at1 cc may b e more effective and creative /// ADA Title II Requirements • Ensure that individuals with disabilities are not excluded/ from programs, services, and activities • New construction and altered facilities must not e any architectural and communication barriers -------------------- " Every-fac itt is-not r-equ 1ii be ompletely accessibl erraccess l oindivithiaIprogra s  •£ v rties, and --------- -------- services is provided in an alternate anner. Recommended ADA Documents Mile High Accessibility has provided the following ADA document templates that should be implemented by the Town. Town staff should be trained on all ADA policies adopted he Town: ADA Grievance Procedure ADA Public Notice Eligibility Criteria Policy ADA Coordinator Nntiee ADA Self-Evaluation/TP Policy Service Animal Policy Effective Communications PolicyEmer enc M _ g Y y enerat P1'ogram-Access-Polly -- -- Reasonable . cc cy -- ------------------- oP qual Emp1omentFolc _A Contra-7= g Policy Mobility Device Polic - -_ =-Town W site Accessibility Policy Transition Plan Requirements • The designation of the ADA Coordinator with name, phone number, and email address. • An adopted ADA Grievance Procedure. • ADA Public notice. • —A list of barriers that limit the accessibility ms activities or services. � = =--- --- • Proposed methods to remove bar iers to accessibility. • _'The schedule to get the barrier moval work completed. Project Scope Held kick-off meeting with Town staff Completed Self-evaluation: • Evaluated programs, services, policies, and procedures • Submitted draft ADA Public Notice • Submitted-draft-Grievance Procedure %! '%ALAI— • Performed-ADA-audits-of Town-aci1 - 1 Town parks • Performed-PROWAG audits of 35 Estes Park streets and lots • Performed ADA audits on 53 trao/(stops and street parking Project Scope • Developed Draft Transition Plan • Created prioritized plan for barrier removal in facilities( • Produced prioritized plan for barrier removal in right-of-way • Conduct public meeting to solicit input from t ---communitY and Town staff (November 9, • Document public input er-Novern e c • Finalize Transition Plan -- Estes Park SurveySummary Priority 1—High: Should be completed within 12 months.Includes findings that have little or no cost,were in violation of the codes at the time of construction,pose an imminent safety threat,or would remove barriers to the greatest number of people to the Town's programs and services. Priority 2—Medium: Should be completed within 24 months to 36 months.Includes barriers that have a lower budgetary impact on the Town in relationship to the degree of access provided and that impede access to higher numbers of people with disabilities.It also includes barriers that are a technical violation that is difficult and costly to remediate and may not result in providing greater access to people with disabilities.Includes findings that create a moderate to minimal impact on accessibility compared to the cost of the remediation. Priority 3—Low: Includes accessibility barriers in employee only spaces.These barriers should be addressed when any employee with a disability requests reasonable accommodations within the employee only — space. L Estes Park SurveySummary TOTAL ADA FINDINGS (High-Cost Estimates in 2023 Dollars) Location Type High Priority Medium Priority Low Priority Findings Cost Findings Cost Findings Cost Facilities 199 $23,995 255 $438,870 20 $13,150 Parks 62 $8,050 39 $110,650 0 $0 Right-of-way 282 $876,745 392 $2.358,010 4 $400 Transit Stops 5 $1,600 25 S37,600 0 $0 On-street Parking 0 $0 4 S21,500 0 $0 Totals 548 $910,390 715 $2.966,630 24 $13,550 i Facilities Findings Totals FACILITIES ADA FINDINGS SUMMARY 1 ADA HIGH MED LOW LOCATION FINDINGS PRIORITY PRIORITY PRIORITY I Broadband Building-1180 Woodstock Drive 14 9 5 0 Dekker Power-615 Elm Rd 29 13 16 0 Fairgrounds-1125 Rooftop 160 72 85 3 Hydroplant Museum-1750 Fish Hatchery Rd 21 8 10 3 �j Moraine Ave Restroom-215 Moraine Ave 17 5 12 0 �� Museum-20041'St 33 14 18 Museum Annex-220 4°St 14 8 6 0 O'Connor Pavilion-1700 Fish Hatchery Rd 11 4 7 0 Parking Structure 1-691 North St.Vrain Ave 8 7 1 0 Town Hall-170 MacGregor Ave 103 29 62 12 - _— Transit Hub Shelter-1209 Manford Ave 12 4 8 0 Visitor Center-500 Big Thompson Ave 47 23 1 Water Shop-1360 Brooke Dr 5 3 0 TOTAL FINDINGS 474 199 255 20 2023 Dollars Cost Estimates $23,995 3438.870 $13,150 Estes Park Parks Surveyed Birch Cabin Bond Park Baldwin Park Centennial Open Space at I( illows Estes Park Playground round & R7enst°r101-0Wms GeorgeHixMemoria1 Mrs ova s_ ar en Estes Park Parks Surveyed Performance Park & Restrooms Thumb Open Space Tregent Park & Restrooms Women's Heritage Plaza --------- ------ _.-- Parks Findings Totals PARKS ADA FINDINGS SUMMARY ADA HIGH MED LOCATION FINDINGS PRIORITY PRIORITY Birch Cabin—355 MacGregor Avenue 0 0 0 Bond Park—170 MacGregor Avenue 5 3 2 Baldwin Park—271 Ivy Street 4 4 0 Centennial Open Space—East Wonderview Ave 7 5 2 Estes Park Playground—East Riverside Drive 25 17 8 George Hix Memorial—111 East Riverside Drive 8 4 4 Mrs.Walsh's Garden—West Elkhom Avenue 3 2 1 Performance Park—435 West Elkhom Avenue 20 11 9 Thumb Open Space 2 1 1 ==-----_----- Tregent Park—219 West Elkhorn Avenue 25 14 11 omen's Heritage Plaza—Riverside Drive 2 1 1 TOTALS 101 62 39 2023 Dollars Cost Estimates $6.050 $110.650 Estes Park Streets/Lots Surveyed , /Big Horn Parking Lot North Court Town Hall Plaza Big Thompson Ave Park Ln Virginia Dr Community Dr Performance Park Visitor Center E Elkhorn Ave Post Office Parking Lot W Elkhorn A E Riverside Dr Riverside Parking Lot W Riverside Fall River Rd Riverwalk First St S St. Vrain Ave Fish Creek Trail Second St -------------- %%= Fourth-St---------------------------------- South Court rake-Shored Trail Spruce-Dr ---- ------- -' _ acGreg Ave -Spruce arcing-14a ==_______=_ ------------ —-Manford Ave----- St. Vrain /Big Thom Moraine Ave-- St.Vrain Ave Trail Moraine Ave Trail Stanley ye; N St.Vrain Ave Third Street ... ../ . ..., .., Public Right-of-wayFindin s Totals :::::// . /// / ,... ,. / / Street Curb Ramp Curb Ranry Sidewalk Sidewalk Street Street Total-Low Total-high Total-Low Total-high Totals Low Totals lligh $9,600 $10,150 .'a 51D8 $8,650 $10,250 . , • . . , / . Big Thompson Ave $21,050 $24,200 $390,850 $511,700 $411,900 $535,900 $4.750 $5,500 $6,900 $10,400 $11,650 $15,900 $10,050 $12,850 $411,475 $a61�050� $50,525 $73,900 ECIEEZI ..'..00 24." $121,200 $181,800 $121,200 $181,800 CEEMI $0 $0 $45,600 $45,600 $95,600 $45,600 $1.I50 $1,800 $52,200 $79.3W $53.350 SB0,1Da / ® $1,000 $1,500 $4,400 $5,100 $5,400 $3,600 $350 $400 • /i ' .. $4,200 $5,D50 $250 $3W=EliEMEZSEI $14,800 $17,200®" '' ' '®' • $700 $800 $44,000 $66,000 $44,700 $66,800 $13100 $15,900®' $32,350 $52,225 % 121=1 2..: :1 $45,600 $45,600 $45,600 $45,e3r i/ �� 1 $0 So �� Performance Park $5,000 $6,500 MMEWEell $18,345 $26,225 // % ,, Post Office Parking Lot $11,700 $14,300 $13,900 $21,000 $25,600 $35,300 ��� Riverside Parking Lot $6,000 $8,000 ''®' ,®' / /��/� 07,850 $9,900 $46,100 $71,150 $53,950 $81,050 �/% ,, $59,300 $74,700 169,750 $104,650 $129,050 $179,350 / /� -- ® , $52,000 $73,000 $52,000 $78,000 % _ _ Sault Court $30,400 $45,600 $30,400 $95,600 /r1 �__-_---- Spruce Dr $5,000 $11500�� ---------------- Spruce Parking Lot $1,000 $1,500 $4,350 $6,600 $5,350 $8,100 St.Vrain/Big Thompson $3,000 $3,500 '®'' ' '.'o ' St.Vrain Ave Trail $5,600 $6,400 Stanley Ave $4,000 $5,000 '®. ® , 1, $70,000 5105,000 $70,000 $10.5,000 $0 $0 $5,200 $7,800 $5,200 $7,800 Virginia Dr $5,350 $6,900 $11,975 $18,000 Visitor Center $350 $400 $32,600 $47,850 '®"' ' W Elkhorn Ave $5150° $66,20° W Riverside Parld Lot '. STREET TOTALS 2023 Dollars $266,400 $329,950 $2,130,840 $2,905,205 $2,397,240 $3,235,155 Right of WayFindings Totals ,... _ PRIORITIZED PUBLIC RIGHT-OF-WAY FINDINGS IN 2023 DOLLARS Priori Level Findings Total - Low Total - High SIDEWALKS AND CURB RAMPS , Al-A3(High) 164 $382,900 $542,725 B1-B3(High) 118 $248,375 $334,020 Cl-C5(Medium) 24 $28,975 $38,600 D1-D5(Medium) 142 $1,623,435 $2,157,740 / A4-A5(Medium) 115 $60,450 $83,900 B4-B5(Medium) 111 $52,905 $78,770 E1-E7(Law) 0 $0 $0 A,B,C,D 6-7(Low) 4 $200 $400 -------------- TRANSIT STOPS High 5 $850 $1,600 Medium 25 $2,650 $37,600 Low 0 $0 $0 ON-STREET PARKING High 0 $0 $0 -- ------- Medium 4 $21,500 $30,750 --- Low 0 $0 $0 Totals 712 $2,422,240 $3,305,105 Estes Park Transit Stops Surveyed Blue Route Red Route Brown Route Gold Route Silver - / 1 /7, Transit Stops Totals TRANSIT STOPS Cost Estimate Range # of Findings Low High Priority: High 5 S850 $1,600 Medium 25 $26,250 $37,600 Low 0 $0 $0 TOTAL FINDINGS 30 $27,100 $39,200 ---------- / j; Estes Park On-street ParkingSurveyed Big Horn Drive McGregor Avenue Park Lane W. Elkhorn Avenue -------------- AlA On-street Parking Totals ON-STREET PARKING Cost Estimate Range # of Findings Low High Priority: High 0 $0 $0 Medium 4 $21,500 $30,750 Low 0 $0 $0 TOTAL FINDINGS 4 $21,500 $30,750 /7,,,-7/ / j; Next Steps • Town Council approval and adoption • Complete ADA policy development • Identify funding for barrier relllovai 41 A AAAA Questions / Comments? AA ///, Page 10 A IP TOWN OF ESTES PARIc, Report TOWN ADMINISTRATOR'S OFFICE To: Honorable Mayor Koenig Board of Trustees From: Town Administrator Machalek Date: January 23, 2024 RE: Property Tax Work-Off Program Purpose of Study Session Item: Discuss a program that would allow eligible individuals to work off a portion of their Town property taxes. Present Situation: The Board expressed interest in learning more about property tax work-off programs at the November 14, 2023 Town Board Study Session. Proposal: Colorado law allows taxing entities within the state of Colorado to establish property tax work-off programs for taxpayers who are 60 years of age or older or who are living with a disability (C.R.S. 39-3.7-102). In order to qualify for a property tax work-off program, taxpayers must own and reside at the property for which taxes are due, and the property must not be income-producing. While numerous county governments in Colorado use or have used this provision of state law to offer property tax work-off programs (e.g. Boulder County, Douglas County, and Pueblo County), staff's cursory review did not identify any municipality that offered such a program in the region. Larimer County used to have a senior tax work-off program, but eliminated it in 2023 due to the difficulty of administering the program and cost escalation in acquiring a worker's compensation policy to cover the work-off participants. Additionally, the County had a hard time finding low-risk jobs that were a good fit for the program. Staff would not recommend that the Board consider the creation of a property tax work- off program for Estes Park. Due to the Town's low mill levy, it is unlikely that the benefits of a program to individuals would outweigh the administrative costs of running a program. Additionally, finding jobs that are a good fit would likely be difficult given the size of Town operations. Finance/Resource Impact: Property tax makes up $445,314 in the 2024 budget. A property tax work-off program would reduce these revenues proportionate to the amount of people who would participate in the program. Based on Larimer County's experience, Staff expects that the financial impact would be minimal. Page 11 Level of Public Interest Medium Attachments • None Page 12 ift s sta . nab . i . ty Visit Estes Park , _ • ilk 1- t. 406. r AR . . . ... ..,. ..., 2414,1, , . 'Ls. •.._ 4 _ _ . I 1 0 1 Dana Paiement & Rachel Ward Oppermann � ,: , - - ., 4' . -_� • • ar. ge.-• •- .'•--er %.10."Apistir 4 `1001-71:1 - •.44:i A itleAt Lt, �••_ ; r i 46 f , ESTES PARKItCOLORADO F 4 . A • Pd\411111%. i II- Page 13• Dedicated it . ustainabilitlf Destination Stewardship is Our Cornerstone Destination stewardship guides the development of our strategies and informs our daily -11k ;„�� decisions. It allows us to work toward striking the right balance between enhancing the visitor experience, promoting economic vitality and preserving the quality of life in the Estes Valley. i _ - - "�',._ It necessitates the careful consideration of our work's economic, social and environmental impacts and implementing strategies that ensure they are positive. The long-term sustainability of our destination depends on this balance found through destination stewardship, both as a PA place for our guests to visit and as a thriving, vibrant community. Ilk . , s � .. ,. 01,44is • -'I") , Page 14 *From Visit Estes Park's 2024 Operating Plan ............... ,w GOAL . „.,.. A...4:4 - Develop exisiting and build new .. . that contraBute to theprograms - r1,4 pillars of sustainable tourism and �: � =. ;�� S 4i �' 1 L r H' , 4 . ,,, v .� _ r. j i Ii�if'y tourism advocacy within our -�- -�- = 1.�c i.a I ' � ., : ddestination r,. r . ,1 :„ ic-- Page 15 arth Week in Estes Park April 21 - 28 , 2024 GOALS • Educate and inspire visitors and4 . residents who are environmentally- conscious while providing events �. around sustainability for them to enjoy ( • Drive visitors into businesses �-� ` ■ n rn nal Dar Protects Saves CommunitynWildlife EnerJy Astro Tourism is becomingincreasingly with individuals Darkpopular, visiting Enhances Promotes Skylocations to esca e lightpollution pHealth Astronomy and reconnect with the natural world . I- r. . Boosts Tourism • ,* tr `.. � ' Fes, . `� � .• 4 Page 17 4.04, „... ,...e," Dark Sky Mentor Program through OEDIT and Dark Sky Colorado C 0 LO R A D O Office of Economic Development & International Trade Steps for Certification • . 1 . Convene a Coalition for the Stars 2 . Conduct a Sky Brightness Measurement Program 3 . Engage the Community with Dark-Sky Education & '{ "t. ' - . .0. , . Outreach _ 4 . , . . - 4. Develop a lighting Management Plan 5 . Set up a Policy Planning Framework i 6 . Inventory Outdoor Lighting A , z*,_______ \ Page 18 0. _ . .. ero i aste Events ..!....,. ___ aF \\M� ... .., , , .. . . „, , ,, ..i.....4,.. , _„.. ..,.. .„„.. •.. ..... r� ... _ .. N ti` _. ....i. i s ._ i ,.. ./....._. - - _u_ _ I,• We are workin with the Events Center =� ii T , . 7 i' , lid `.. }-a, � to see if this is an option for Frozen ��� � =T =. I Dead GuyDays , _ . . i . ...• This could be a model for other events _ -'----------,----------(-,--,----;-'.-.-.,-- "--,."7I..•.,•-...7._.'.'-:-.-.-...•-...i,.." =.. 7...,:--;i-_„_,q:.:_-e.0•.:,e.1.4Z.' _.1-.1,,i.-.A„7-.,i....,;•..,-,:...„.'It:„'d.i... .. .. ,0...5. i i:'a _.RTC f _.� t' i1��a--- n Estes Park : (k �� :-A"i 1",..V ti a „_- _ ........141,11P' '')11w_ Pi,,.;„ r.,.,,,,„... 6r- pliC .., ,... ._. , 4.4144 a .! ' ---- . ., — Page 19 _ _ I . GOAL . .... ■ •. , C _ •�'it . de. . f_ -",' n� -..„1•,. .00/0..s. , _ -• 4,, Present Estes Park as a '44, , .�. •. : " . T�`, Ifs t 1• C t ,4 .1i :- • r welcoming destination by -... ; ; j-.. - . integrating messages of inclusion � ' � -� 4. g g g _ _ ...- Apt A id. _t and sustainabilityat all levels of = = • = - -__- - = guest communiations .• • = = .._ —. = - - _ ....r... . __ __ _ --- ..- Page 20 t I I:; r.` •: It ! $ • r •17 . wheel • theworld • com . , , . , . .. „010 • • , ir - -.- .._ , ... ..,,, , .,.. ,,.. ,..... ..411 . . ., bi(e,„Aqt,, , t ••I, .. • •t 4 • • jokil$# ......,--"-- . ' • '4. , irivAdv.z.,: An accessible travel booking pplatform with _,....... . 4 , . /1(1 40 �,. _ P•"wt.'s- detailed and verified accessibility , .. . • •�j- �J = ,,,, „dr information , designed for people with � �� I. '�' .r ~-�� accessibilityneeds to travel . , .....r .: . \. .:�T - .tr1p -. -w - 14�t ' r i i _ • .' ah� 0 a, ,...c) t,, timnr:... tivil _44.111111111M14 ..7... ,,, • t.i,.., . ; • ,N ..\, , ,,,,.....,. . . . ,, , .. ,,r .: - THE WORLD'S LEADING SOLUTION r_ , ., ,.. • , , i . „JAN.; - _ , , . de k _ FORACCESSIBLE TRAVEL 114 • f I1, TRAVEL+ c1 'i'_., . --""�•�•-•. - ` lonely planet 1 ,, ----�-- LEISURE 4111, UMNTO • 14_, W - _ w i�_«1. ..w. 4 ` v. • M. N Page 21 111 - _ - •., s INCLUSIVITY & SUSTAINABILITY We exist to inspire reverence for Estes Park and the lands that s,,rround us We wish to share this beautiful place with everyone and strive to ensure that every single person feels welcomed and valued in our community whole being thoughtful of those who came before us I ■ We pledge to be good stewards of our destination by helping our guests Do Estes Right,including respect for our wildlife We're a community-first organization dedicated to practicing responsible tourism and supporting our workbroe, We acknowledge that we are marketing a destination operating on the Native Lands of the Arapaho Uta and Cheyenne tribes. htlps:llhativrMnd-d/ Sustainability 11,1*- ..........,teteutxcete . ri.-.-iprztv...:, _. .. . ., . 0, 4._ ., . .. . , . .. . .. . . .. . .%. 1 Pages • • i y • x,; j 1.• it i•d%-p le f 7.00i• IVI 77 :• .r.i.4A,I d r g.em ice AI +_ 4 : LIT t a . i ~V /' • i • _ ;* di 1e Page 22 Accessibility: with • W visitestespark.com It Q ` 1 WEDDINGS GROUPS PRESS _ BLOG SEARCH THIS SITE... Q Setting e a n afor CHECK RATES LODGING RESTAURANTS THINGS TO DO EVENTS PLAN ROCKY MC Reset A �Z' w�' 0 Show shortcuts(d) MEI aAccessibility _PARK— COLORADO Focus Cursor Highlight AudioEyeos industry-defining digital accessibility hybrid _, ,. O ODAr offering helps deliver website remediations efficiently and _ Contrast Color Shift Animation affordably for organizations of all sizes. Our platform I :.����. . , J.: Text Size Spacing Font leverages a decade of investment in advanced %= . . '' A i technology supported and informed by our team of V Guide Window Images dedicated IAAP-certifiedprofessionals to helpdeliver 4:. . ,. s: ., r - pa ,l 1. -, o 4 tiMe ,,.- h. Settings C. Help O improved access to the web. � s{ ±� `' +�+ '� li r, i'► 4 y W 1 1 audioeye Page 23 41111114116 sr qiir It thilto--""Iniii7041116mhilmv_ • 406‘"' GOAL . .i. ",.• ,.. Aj ¢ » ' 1 {r t \i,ti , t ' , ' t. , Use storytelling to showcase the - � �''" ran a of activities and businesses44t , r ,offered in Estes Park and educate .>. . . Ilk 1,14 it NI 1 h guests on how to do Estes right . t . Y r r -a 4 i r j ; • >i ., Page 24 ESTES RIGHT= Do Estes Right ► Play all ` . , .-.1 * '�7iR ,, . " • _,ice. ` 1 �' At , , ' - - ..it4 .4...'. - ':''' tail �—` PAi AND T1MED-ENTRYbit w • y. f ;• , • , � ,400 s NO TRA StWUTTIE SERVICE PE AIT SYSTEM y ,. .',ti Ti n 115I1F'E OLD -1 1:17 1:15 • an s '' 1:15 > - 1:08 1:36 Do Estes Right: Parking and Do Estes Right: Timed Entry Do Estes Right: Know Before Do Estes Right: Leave No Do Estes Right: Be Careful Do Estes Right: Keep Wildlife Shuttle Service Permit System 2023 You Go Trace With Fire Wild Estes Park, Colorado Estes Park, Colorado Estes Park, Colorado Estes Park, Colorado Estes Park, Colorado Estes Park, Colorado 3.3K views • 6 months ago 6.6K views • 6 months ago 82K views • 1 year ago 46K views • 1 year ago 87K views • 1 year ago 80K views • 1 year ago VisitEstesPark. com/ DoEstesRig ht Page 25 _... Earth Week: ilk .:, .. 4,.... , , ; 0 . , .. . t . r Is _. . . - . . .., . . .z, - • .,. Working =� - . 'qir r j T -,-i. -- . -,',' to build out events to support the topic of sustainability ...,, 1T- . - _ - -Itil ..e _ �y . a t7' ' .:'*‘: ‘4L*I'' 7P' '4, i: : tg . ,.;,•:: 4 . ai, 41,11i.--, imbs - ' --* .%. .4-,.";' .:7'' .L.,* 1%., FestivalNick Molle . , � : � " .1 i _ V � •- y. am - _ , = , - .; .. * •, ., • ' 1! -74 • Environmental Film 4 � 1 • • { ! *kW. .� ,1 1 , ; g 4 �,,� . ,„ �:Productions/Rocky Mountain Channel & The Estes ' - - . - < < •.,%' " 4� '`- - L Mil 4 ‘ • Lalilt �*- --It, r . Nter; :. ..r. c____ r E 4ie Valley Watershed Coalition • Student-led film Environmental Film festival : Estes Visit Estes Park: Park High School & Estes Valley Land Trust. • Sustainable Storytelling Event with the Fine Arts Guild Community Roundtable • The Estes Valley Watershed Coalition Symposium • Clean Up Daywith the Rotary • Sustainability in • Leave No Trace Event our community Page 26 r Environmental Film Festival with Nick Molle Productions/RockyMountain Channel ----,(°e-2;---- , , .k_f;44 .,,V P V ...ow •••'' .....wo - Friday, April 27 & Saturday, April 28 ..... alP11010. Ma Ma IMOOa ■■ ■ ■■. •■ if ::::: is , siii Minn is ■ urn: II Miill.1 r I ■ilUU■ as imi moon se - _ NI IIIIIIIIIIIIII IIIII gil 111,‘ ,,,‘44 liw. ,...... , . III 11111111111111 II P ,.. ._ •—07 ' ' 70:1:: -*-:'4,. 1:-JAI in .4. ;4• ilt 4. _ - Min ___u glial Z. r, • t . ►ill E11BitElril,iita1/. ' • ; ' - .t !, , • .., !00 HISTORrCPARKTHEATRE CaM 2D 730 PM 3D . 4 ,:i; c , .: ) It I , . 2. -2 _ ' D li M MI . ., .. .... . .....6, , ... :igilli r. • ,... •-r .........- 44 - ^i ':'e, r _ _ _ , _ _. ___ _ _ ,- . ttlet J i II4, I°� .. 'I; IN a -N.. ' . ... ... • II IIP r:- 11! .111 .. 4i ■•■ ROC KY MOUNTAIN , --- CHANNEL , . , . . , ....i...______ • \tt,. -. - . , .. . , _, .. . . e27 Student- led Environmental 410 t S Film Festival ESTES PARK _�_ School District R- 3 — -- Thursday, April 26 Estes Valley Land Trust Estes Park High School Topics include: • Climate Change / � � • Wildlife (L t • � , �14 - .- - • Equity, Justice & Inclusion • • Adventure & Explorers �'~ I ---�' i fr 41 ': ,,, • Conservation & Restoration � � a�° A `„ (144- , r '' • Art & the Environment '`�X • Our Connection with Nature , 2=, �,, , .. rt: . ' :-/ Page 28 stes Valley Watershed Symposium atu r ay7 p 4 _, . 1, r + ' A `.. 3 I .. 0 4, `r i• Ili . 11 • �±, * ,, r �2: •'. it * t • :31 : 1111 1 •. ;� . ' .• fk t t • ' il 1 1. II • 1. • . , • ifiatitio. o' 4/' •. • • ' ........4......"‘ s 3,40 , r ,.0410� \ `.•I .•yyyy w� ,i. w t ,�+A. _'- 4 •♦ t - 4-r _ v y�• ,;.." 0- �, _ . . .�- j - , rr;. : . , .tom - ESTES VALLEY 1. • 4 • .Y .. �k" _ _ ;�i r - 'f A fir^ .•: ; _ ,, ?•. . 4. �..�� WATERSHED k . • t ... , ..._ ti - Ai , • _ ��.• '`,L• ' -\`• y`'.per-� ` •�- - •_�,, ..� � •l• c 7P�� •4 'NA {" .. 411'. �. L 4.� "� ' �,l , rt` , - C 0ALITI 0 N ... .4 ` 777 4 . ,� ,� • . �.- ...... Water Forests • Wildlife • .7'. it -,.. p•r A A• "0" '7"- ,, - anr:411rP: it, . „ P • .. ,�•^ 1 . • ter j =r ttr th . ►.:: �� ,. �+ `,� riw ,,�:t i. <, -.+�. Page 29 3 +� r .l 3 -to 1 —ASustainable Cit. 1 1 LCI gprkies o the k \,,. ‘ ‘ ,,,,.. \ ing Even . _ , _ _ . • • ... ... .... ,. ' ! ► •, ii ... . . , ...A . . • 1 . 1,45:: , . . L' iiiiiI 'i • « : --11( .: IL l .4. A r 1 r Z 7i ir 'I III // uuu MI '� �. tilt II IIIIII II ' di . // ■ .." MI � ' II ! THE MOTH StorySLAM •1 Tiling•story torrgM' ...misird;Z:?.•2=''o. I. WO HIST0R1CPARXT1EATRE C0M 20 730 PM 30 445 PM I`ao _ ).11211E0BaliliiiIiiMiriBIR I . 0 I ,4* \I is DUMBO \ Page 30 Visit EstesrCommunity s t ib . i . ity in ou community 1 . .041_, ark .,. ..J if OF i sr lYi'illir)t- is .• 49 a Ala •'''Ar li.-g 'r• '.; , di- -• —I.--....- • ! ! • '� V ..• t 4 — r� - lkev� ! - -----, 1%.33.7 .Y:1:1 -111W__ ., , ... ... • _ _. ....., • . - .. ..114k-n? A= • .r um: ,f, 4,, AVAILABLE , ., , -. 4,i ILI so- 4* ...ii:'' le i 1 _ ...... ....._._ - :110. r_ IP ler.- -Ilk • Nib SPX"' - \Will I ••• -* . C011161.0RADO i _fre, '. .. ..1 .0.1.•••• , , ,, 0" • • u111 fir, - • Wilr. PPP- / % '_ i ger. _' l/ ♦L}: sr z.t I t w 1.� rr µ J. t -1 _ `"f`, .r \' 'e f / 4+ 14i'<; •'`• / l / J 1 "A�a i rr� , ! yl d� ' �i .. f • �! �y [ "• • ) � J� 1 { / fit a�i� . �114, • !1C f if .T 'S 014 110.t 1 •\v t - R i �• '' ��r�� • • • - , :.11:: .�� jj . . i if ., s -•� S t fit. . ✓ AN 7r _ ( • 1 • :• ID I ir♦ • Page 31 Discussion 1.11111111 Speaker Ideas for Community Roundtable? LE1 AGUE OF WOMEN VOTERS ___ .11r11-7 Oh ES I ES PARK �• r I DISCOVERY LODGE - I '"• ;.'_ l'i : : vii ..• . . . ESTES movingtoward zero waste RECYCLESNi. . 1 Y.A. f 1 ESTES VALLEY , . .7„,„ -, --- WATERSHED .. ,•_ . , `�•_ � _. �." .. . - -. •. . COALITION LEAVE NO TRACE .11. N AO -�- - �1 Water • Forests • Wildlife Vanessa Solesbee . .. .. . . . 1 ..: _ . ,,, . .,.- ::..._. -i . i„ . , - Estes Valley Land Trust ' 4 (.4(SN41111:4.4.0*-'),:j;i s .. . . AO - , . �, i t• 4 btio. _ "PP . . ,,4 ' . i 44 4. if . 4 1%. 0.$11kri'. ,, PI): 41... ti i i'V.4e`i.!Orli • . ti *)ttttilstsc 4 S. Illit..4. .ir tir.r 4:4Pier:-.4‘. ‘ 4k r,-••••t.4,4 t.;4#. , ,)I4 t..ft..'•. tSti.ll'1,. 0'4'4, • : ..,.4,k4 -. 4 4I,.4-t.' . ieril.s's. . .� •" .6 11•11.C,.1 i•t‘i I)i:4 44-,,f.,l• li 8. '. .... , 4 •, • y_i. . i i•:11 11IP• 1A1... •,' ,_Z_I.,. Pi l.,le , , iV, ,'.11 . '1 \,h..,, , . ) '.f,,,'_', ., •• •I •.. :•. ilir,1, •..: • ,1il • N..%1•1ik 1411.4 r41. .V •'•74 .4ir • 1114 1. _ 1 1 •' l ' _ii ' • ,4 ‘4• !k..it,t 4)... 4 t _ R' 4a } 1 t itt' • •••-'" • 4 ,..,.. . . .,„, A .. i 3, it .. . t -0 • °A-' rb i e 4! a. ' - . - k l' t. ii k a k , . i % , IF ill) . , A4 ., ,11, . _ . - , , ‘ 1$ 4 , , , • , ,... , . . . . , , . , . . A. _. , . , ., 1 t 44.,1 i . 4r, . • • , i t 1 ' .. . .i ,s .. V 1 „ 11. , , "it - 4 itio. , ,A ; .-,r A.4. 1, la • : 0, ). 'i C , . . . 1 )1- . . iiiki: . . 4 •11 .• % I' A . • • L 7 , ca i , i tk ...... 4,. 6,- Ilk , _ , . . • • 4 3° • 4 )4tAlt13. 4 . s ,� i r •• i •ibt. -ill; r' , . yr - . It ..i _ . ,,. _. ,. . ,.... .. .. t . . I. 1 , tr- 41 l '."1164.-41,%3.. rii.4% .... - y! s ; t ,,,,)it. • k ' A14.1't 4 ,._ f .; ' ...t.• '.iL. . i 7; :. ) :1,- -, . ,, A t . 0 . .t- . • . . 1.4 3 . it, 11,41' . . , , 1•••• 1", . I. ). 411, . ..0' 1 l' mie. ;... •ill)lo • ' . 1314 '' %- , ti., .- , - . - - ...1, . .,. 4 .- , .e-st. - -‘• ..: .4,-?., A1, _ . -- - -. • _ a ,.. 1 . :st . , v. . :11 1 ,. is., .. , ... • . , : . , +, .. . .. . t _ . . • . 7 . 1 ..4 .. .•#4 kk 4 Ili I'll - - ir. : , tr i 4 , 1 i� a . / � j".1.4. ,. 4; . . 4.1 :b sr. 4t 4 4. ,; ,%‘ ! .t • 1 • ''• • j;- . ' 1 .f. " , . 4.. - - . , . . ! . R • - ••• 1'• C "6 e 4b- • At w , /.1 .- '; \' .1/ ' i - . - It! lot . . . - * Jo.' if, 0 . it. . ...'i i •-iiw..-` ililiPP11.1"111111111111te ..... . 1 - 4-1...51 - •• III Ilt 'I.". • . . MI. 44 'Pilitilli 4 • it 4 1 % ‘-4'. . * .- . . - . 4. , . •-• 4 1.40r -. fAir,)--, .1 - 1 -I64: . - - 1 .4%.4.''° 0, . . 1 ..."1 : • 0 %• it • X. ... 4 t IV .. Ir..• _ 7,..4:el• a . • - 1 ‘ 4 1:21k, • ..)14.1 '. 4. itt: 1111)k illi . : . • ..j 4- V. • 4'll• i. . . . t"" - ' li. 'a". •a is • „ , ' - 0 • .. .. .•-• \A . ` 110 �,•1 . ti-;)1 ' • - ..,. ...* .' - . "I . ' • � +/ � 1 e..14‘• ‘ ,)it: . . 4 . 1 . A .... .... 6: ' iit ♦• w • `_ ice• • �t-4°1... . Ile :4 IkP.'ft: 1141. Its .„:11•Altlit.14:1' . '+! .�- . , • ' 4:... • ,,•: ...::,_ .4,.,._ ....t, . ,. . 4 — I t ' ir.... . ; ti 4° •'. ' -- ,1°. - .0*i.. ,' .1 ' % of • -. •11 i .Iii.110 4 '• % 3 Page 34 EP AL TOWN OF ESTES PARK Future Town Board Study Session Agenda Ite January 23, 2024 February 13, 2024 Items Approved — Unscheduled: • Joint Study Session with Estes Park • Power Outage Overview Planning Commission • Future Use of Town-Owned Property at • HR Strategic Plan and Organizational Elm Road and Moraine Avenue Culture Update • Hosted Short Term Rentals • Bed and Breakfast Code Revisions February 27, 2024 • Governing Policies Updates • Draft Arts Master Plan (continued from • Stanley Park Master Plan 12-12-2023) Implementation • Substandard Rental Housing • Downtown Loop Updates as Necessary • Seasonal RV Housing on Commercial Sites Pilot Program Items for Town Board Consideration: • Electric Rate Study March 12, 2024 • 2024 Street Improvement Program • Encore Arts and Fairgrounds Facility Overview Relocation Costs May 14, 2024 • CIRSA Liability and Risk as an Elected Official Page 35 f