HomeMy WebLinkAboutPLANS 725 Castle Mountain Rd PV Solar 2023-01-09Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 VICINITY MAP SCALE: NTS PV SOLAR SYSTEM DETAILS BUILDING INFORMATION: CONSTRUCTION TYPE: V-B OCCUPANCY: R3 ROOF: SYSTEM SIZE: DC STC: 9.250 KW SYSTEM SIZE: AC CEC: 8.437 KW SOLAR MODULES: ( ) SATELLITE VIEW SCALE: NTS 25 Silfab 370 watt Truss: 2 X 4 @ 24'' O.C. ELECTRICAL INFORMATION: NEW UPGRADED SPAN PANEL BUS SIZE: 225A SPAN BREAKER SIZE: 200A MOUNTING SYSTEM:IRONRIDGE XR-100 MAIN 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 5. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. 6. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 7. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 8. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 9. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 10. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK PHOTOVOLTAIC NOTES: 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED BY RECOGNIZED ELECTRICAL TESTING LABORATORY 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 4. SOLAR INVERTER SHALL BE LISTED TO UL1741. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPED WITH INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. 11. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS. 12. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS. GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER ROOF PLAN SINGLE LINE DIAGRAM ATTACHMENT LAYOUT SIGNAGE 1 INDEX 2 3 4 5 6.1 7 8 9 SITE PLAN MODULE DATA SHEET RACKING DATA SHEET THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: NATIONAL ELECTRICAL CODE 2020 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 AS ADOPTED BY THE STATE OF COLORADO ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES COMP SHINGLE GATEWAY DATA SHEET (1) POWERWALL+ PHOTOVOLTAIC (PV) AND BATTERY ENERGY STORAGE SYSTEM (BESS) (1) TESLA POWERWALL BATTERY 6.2 POWERWALL+ DATA SHEET POWERWALL+ DATA SHEET 10 ATTACHMENT DATA SHEET 11 SPAN PANEL DATA SHEET ELEV = 7880 FT Sealed For Existing Roof and Attachment Only Brandon R. Little Digitally signed by Brandon R. Little Date: 2023.01.06 12:35:01 -07'00' SAFEbuilt APPROVED Subject to inspection and compliance to all relevant Adopted Building and Municipal codes. Changes in Plans MUST be approved. D.GRAHAM 01/09/2023 I-CODES 2015 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION INSTALLATION INSTRUCTIONS AND MANUALS MUST BE ON JOB FOR THE INSPECTOR AT THE TIME OF INSPECTION FOR ALL EQUIPMENT. PLAN REVIEW IS FOR STRUCTURAL ONLY NOTES TO BE TYPICAL ON ALL PAGES AND ELEVATIONS Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 ROOF PLAN1 Conduit Solar Module INDEX (N) Junction Box Setback JB Total Roof Area: 1909 Total Module Area: 550 28.81% of Coverage (N) Gateway 2GT (N) PowerWall+PW+ (N) BatteryBT (N) Span PanelSP (N) AC DisconnectAC (N) Main MeterMM 18'' f i r e s e t b a c k 18 ' ' f i r e s e t b a c k Cas t l e M o u n t a i n R d GT SP AC PW+ MM Solar PV Array 1 11 - Silfab 370 W Modules Pitch: 26 Deg Orientation: 205 Deg Solar PV Array 2 14 - Silfab 370W Modules Pitch: 26 Deg Orientation:115 Deg a a a a a a a a a a a c c c b b JB c c c c b b b b b SCALE: 1/8" = 1'-0" S 180 ° E 90 °W 270 ° N 0° 01/06/2023 Sealed For Existing Roof and Attachment Only REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 SINGLE LINE DIAGRAM2 PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 #ITEM DESCRIPTION QTY 1 PV MODULE 2 PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 3 ...1 2 1 String a: (11) Modules AC SYSTEM SIZE CALCULATION Module PTC Rating (W)x NO. of Modules x Average Inverter CEC Efficiency =AC System Size x x 98%= 8.437 kW AC25 WIRE CHART # MODULE QTY x NEC MULT x MICROINV. OUTPUT AMPS = DESIGN AMPS BREAKER SIZE (A)WIRE TYPE EGC WIRE RATING X TEMP DERATE X CONDUCTOR DERATE = DERATED WIRE CONDUIT SIZE 1 32 X 1.25 = 40A 503 344.4 10.33 X 1.25 = 12.91A 20 (2) #10 PV-WIRE (1) #6 BARE SOLID COPPER GEC 40 X .71 X 1 = 28.4 >= 12.91 FREE IN THE AIR 20 (6) #10 AWG, CU-THWN-2 40 X .71 X .8 =12.72>=12.91 3/4" EMT2(1) #8 AWG, CU-THWN-2 25 600V CALCULATION MAX NUMBER MODULES PER STRING: 11 Voc:44.76 V CORRECTION FACTOR:1.12 MAX SYSTEM VOLTAGE 11 x 44.76x 1.12 = 551.4V 4 INVERTER 10.33 X 1.25 = 12.91A 1 SILFAB 370 WATT SIL-370 BK Voc =44.76V, Vmp = 38.34V Isc = 10.33A, Imp = 9.69A ...1 1 String b: (7) Modules ...1 1 String c: (7) Modules 2 3 6 50A 4 AC DISCONNECT 60A 2P BLADE TYPE 240V NON-FUSIBLE AC DISCONNECT 15 6 7 1BACKUP GATEWAY 200A TESLA BACKUP GATEWAY 2 (1) #4 AWG, CU-THWN-2200(3) #3/0 AWG, CU-THWN-2 225 X .91 X 1= 204.75>=200 NOTE:AC DISCONNECT VISIBLE AND LOCKABLE ALL DC CONNECTORS TO MODULES OR INVERTERS MUST BE OF MATCHING MANUFACTURE BRAND AND STYLE. DO NOT USE 'COMPATIBLE' CONNECTORS WHICH HAVE NOT BEEN UL TESTED FOR COMPATIBILITY.PERFORMANCE AND FIRE DAMAGE MAY RESULT FROM MIS-MATCHED CONNECTOR USEAGE 7 1MAIN METER UTILITY METER 4 KEY NOTES: ·SOLID BARE G.E.C (FREE-AIR) MOUNTED UNDER ARRAY ·PER NEC 250.120(C): WHERE CONDUCTORS & GROUND WIRE ARE RUN EXPOSED ON FROM ARRAY TO J-BOX, CONDUCTORS & BARE GROUND WIRE SHALL BE CONCEALED INSTALL IN CONDUIT ·PER NEC ARTICLE 690.35 INVERTER GROUND FAULT PROTECTION PROVIDED ·ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR W/IRREVERSIBLE CRIP CONNECTOR, ·BACKFED BREAKERS MUST BE LOCATED @ OPPOSITE END OF BUS BAR FROM MAIN BREAKER OR MAIN LUG ON GRID SIDE. WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ ' LINE OR LOAD'. ·PER CEC 250.65(C): CONDUCTOR SPLICES ONLY ALLOWED WITH COMPRESSION CONNECTORS OR EXOTHERMIC WELDING ·ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR W/IRREVERSIBLE CRIP CONNECTOR, ·VERIFY (E) UFER GROUND NEAR MSP. IF (E) UFER IS NOT ACCESSIBLE 259(5,),$%/(,167$//$1(:‘; /21**5281',1*52'$1' BOND SOLAR SYSTEM EQUIPMENT GROUNDING ACCORDINGLY. TESLA POWERWALL + Model 1850000-xx-y 98% CEC EFFICIENCY NOMINAL BATTERY ENERGY 13.5 KW MAXIMUM CONTINUOUS POWER 7.6 KW MAX OUTPUT CURRENT 32Aac MAX INPUT VOLTAGE 600VDC MPPT TRACKERS: 4 SPAN PANEL SPAN 01-00200 MAX MAIN OCPD, 225A BUSSING, 200 FED THROUGH RATED NEMA 3R Communication wire 5 3 20 0 A 3 SPAN 01-00200 Max Main OCPD, 225A Bussing, 200 Fed Through Rated NEMA 3R TO (E) HOME LOADS 3/4" EMT 2" EMT (3) #8 AWG, CU-THWN-2 (1) #8 AWG, CU-THWN-2 55 X .91 X 1= 50.05>=50 4 4 THIS ELECTRICAL INSTALLATION MUST CONFORM TO THE 2020 NEC NEW SERVICE CHANGE REVIEWED BY SAFEBUILT 01/09/2023 INSPECTION PER THE STATE OF COLORADO Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 SIGNAGE3 Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. 3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated 1 2 (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) 3 4 5 (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) 6 7 8 9 (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) 10 (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV ARRAY J BOX INVERTER INTEGRATED DC DISCONNECT PV SUB-PANEL * if applicable SUB-PANEL * if applicable AC DISCONNECT * if applicable METER MAIN SERVICE PANEL 2 1 3 4 5 6 7 9 8 10 7 9 8 10 7 7 9 8 10 *if applicable 11 (STICKER LOCATED ON THE PV SUB PANEL) 11 12 (STICKER LOCATED ON THE MAIN SERVICE PANEL) 12 CAUTION AUTHORIZED SOLAR PERSONNAL ONLY! CAUTION SOLAR DC CURRENT PRESENT DURING DAYLIGHT HOURS WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE RATED MAX POWER POINT CURRENT- AMPS RATED MAX POWER POINT VOLTAGE- VOLTS MAXIMUM SYSTEM VOLTAGE- VOLTS SHORT CIRCUIT CURRENT- AMPS WARNING! ELECTRIC SHOCK HAZARD. DO NOT TOUCH THE TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. PV SUB-PANEL ONLY AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac THIS PANEL FED BY MULTIPLE SOURCES (UTILITY & SOLAR) SOLAR WARNING! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUT DOWN 40 13 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS REVIEWED BY SAFEBUILT 01/09/2023 INSPECTION PER THE STATE OF COLORADO Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 SITE PLAN4 Solar Module INDEX (N) Gateway 2GT (N) PowerWall+PW+ (N) BatteryBT (N) Span PanelSP (N) AC DisconnectAC (N) Main MeterMM Cas t l e M o u n t a i n R d GT SP AC PW+ MM 384'-1" 155'-3" 57'-6" 193'-10" 228'-9" 707'-7" 203'-8" 389'-4" D R I V E W A Y PROPERTY LINE 96'-11" 67'-9" SCALE: 1/64" = 1'-0" S 180 ° E 90 °W 270 ° N 0° REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 ATTACHMENT LAYOUT5 MODULE WEIGHT (lbs) # OF MODULES TOTAL MODULE WEIGHT (lbs) RACK WEIGHT (lbs) TOTAL SYSTEM WEIGHT (lbs) # OF STANDOFFS MAX SPAN BETWEEN STANDOFFS (in) LOADING PER STANDOFF (lbs) TOTAL AREA (sq.ft.) LOADING (PSF) 1047.5 209.5 1257 88 24 14.28 2.28 550 25 41.9 SOLAR MODULE BlockingMaximum 6" Truss: 2 X 4 @ 24'' O.C. 1. 2. 3. Roof attachment hardware to be mounted to existing structure ( ) with 24" O.C. rail spans or less. 4. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the center of the roof 5. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper. Finished roof surface is One layer of . Truss: 2 X 4 @ 24'' O.C. COMP SHINGLE IronRidge FlashFoot 2 Attachments IronRidge XR-100 Racking System RAIL ATTACHMENT TRUSS PV MODULE FRAME IRONRIDGE RAIL DETAIL, END CLAMP FRONTB IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL FASTENING OBJECTPV MODULE FRAME IRONRIDGE RAIL DETAIL, END CLAMP PLANB IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL FASTENING OBJECT PV MODULE FRAME IRONRIDGE RAIL DETAIL, MID CLAMP FRONTC IRONRIDGE UNIVERSAL FASTENING OBJECTPV MODULE FRAME DETAIL, MID CLAMP PLANC IRONRIDGE UNIVERSAL FASTENING OBJECT IRONRIDGE RAIL IRONRIDGE FLASHFOOT2 A IRONRIDGE RAIL PV MODULE 0.4xL MAX. CB D IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL FASTENING OBJECT IRONRIDGE FLASHFOOT2 IRONRIDGE UNIVERSAL FASTENING OBJECT (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 IRONRIDGE RAIL PV MODULE, BY OTHERS (E) BUILDING STRUCTURE (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 IRONRIDGE RAIL PV MODULE, BY OTHERS (E) BUILDING STRUCTURE DETAIL, FLASHFOOT2 SIDEA DETAIL, FLASHFOOT2 FRONTD 5/16" STAINLESS STEEL LAG SCREW MIN. 2.5" EMBED INTO FRAMING MEMBER FRONT VIEW SIDE VIEW (E) Truss 3.0 12.0 4.50 9.0 3.67 3.56 1.02 IRONRIDGE ATTACHMENT AND RACKING DETAILS 01/06/2023 Sealed For Existing Roof and Attachment Only REVIEWED BY SAFEBUILT 01/09/2023 PROVIDE ALL RACKING INSTALLATION INSTRUCTIONS AND DOCUMENTATION TO THE INSPECTOR AT THE TIME OF INSPECTION Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 6.1 POWERWALL+ DATA SHEET REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 POWERWALL+ DATA SHEET6.2 REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 MODULE DATA SHEET7 REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 8 GATEWAY DATA SHEET REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 9 RACKING DATA SHEET REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 10 ATTACHMENT DATA SHEET REVIEWED BY SAFEBUILT 01/09/2023 Project Name: Terry Caldwell - Summit Property address: 725 Castle Mountain Rd Estes Park, CO 80517 DATE: 12/15/2022 Elevated Independent Energy Address:7000 Broadway #104 Denver, CO 80221 License Number:EC.0101394 Phone:970-460-4970 SPAN PANEL DATA SHEET11 REVIEWED BY SAFEBUILT 01/09/2023