HomeMy WebLinkAboutPERMIT B-9599 335 E Elkhorn Ave, Library, upper remod 2014-03-05Received Date
Town of Estes Park office
, „of coo
Received By 4;,41;(:) Commercial Application / Building Permit
Department of Building Safety 170 MacGregor Avenue P.O. Box 1200 Estes Park, CO 80517 Application Expires
General Information (970) 577-3726 • FAX (970) 586-0249 •
Note: Use this form for Non-residential and Mixed -use Buildings
Job Address: 3.3.5 15/44,001.)
Permit Number
Permit Expires
Lot Size: sf/ac
Lot: Block: Subdivision: Parcel it Scagf Z
Owner Name: A-114. 1.4WV Phone: 9;;''in2 2; 45 5649 .
Address: E Elk-1141\Z ikt__
Contractor: Etm
Address:
a a
Town License #: Phone: 970224-3127?.
FM MA 4- PA Dretiv-e_ 6,0
Email Address (REQUIRED):
zikUes-les . a)/71
The Following Applies to New Work Only — Complete all that a
Building Use(sl:
1:INew Building
Existing: Proposed:
VIA1feration
Existing Fire Alarm
121 Yes 0 No
Existing Fire Suppression
0 Yes No
CiAddition
New Fire Suppression
0 Yes 'No
0 Estes Park Sanitation 0 Upper Thompson Sanitation 0 Private Se tic — Requires Applicant to first go to the Health Department.
flurritTHY
fixtures:
0 No 0 Yes —State and Town Lkenses Required
0 Add 0 Relocate 0 Replace 0 Demolish
0 Existing 0 New - # of Meters: Meter Sze:
EMYRED
PERMIT C11„„OREIC
II
vedi
Service:
0 No EVes —State & Town Ucense Required. State Permit 0000 Required. Existing 0 New 0 Overhead 0 Underground; 0 New Afinkl*Slottethline.
# of Meters: ; Meter Size: amps; Temp Meter: 0 No s Phase VoIt
Type of Heat: 0 Gas
0 Electric
Building Height:
Ft.
# Floors
0 Furnace
0 Boiler
Fuel Gas Involved: 0 No 0 Y-. —Qc1lfkatIon,Wdysfem Sizing Required.
Type: 0 Natural Gas
2nd Floor (sf)
Basement (sf) ' Floor sf)
Fin Fin Fin
Unfin Unfin Unfin
Job e cription:
jp44,tvilso P-oo".5
elatsr/69/4
Attached
Detached
eck w/o Roof (sf)
crHFy t apnVicattort is true and c raect and agree to perform the work z cubed accordang to paansispecaricatio uLn1 t ,rev ewed and approved, and comply wlth local
rdanances, state anal federal aaws as well as building codes, a certify that 0 have the property owner's ao amity and permisslon to apply for this perTTA. Addidonany, I UNDERSTAND
THAT 1 AM RESPONSIBLE FOR ANY FEES OR EXPENSES INCURRED FOR PLAN REVIEW, PERMITS, INSPECTIONS AND OTHER FEES ASSOCIATED WITH THIS APPLICATION.
Contractor 0 Owner 0 Owner's Agent 0 Tenant
rom Frwc/S
gnature
Job Description:
Applicable Code(s):
ZOO ;(:1, 0:J;
Occupant Loads):
Variances (attachea
Setbacks
Zoning
Building Of
Date 3
Print Name
7:-?1,172;4/(2ef Ar15,7,07
Type of Const.
142
y 4),
FlootfloadiO:
/
Fire Alarm System
Side Rear
Fire Suppression Syste
Ruver
Hazards Geo Wildfire Flood
Date
Public Works
Water
tJ:ht & Power
_Planning
Building
Plan Review
Coun Tax
Cert. of Occupancy
Other
Tot&
Approved
Disapproved Fees
(47
, (.„),
daaaa;a', aka',f r?ai)Vhr""abai7,aa? 7,-;"7"r-
SaSceveranduildies)ipfdaellMSnoiRefcrences, JhuildingiApplicalkairas\Commerciaa Bundling pernanl(linunercial Building Pernlit 20 1 APPROVFadoc
Revised 9/1912013 - KT
� TA
March 4, 2014
Thorp Associates, P.C.
Architects and Planners
Mr. Will Birchfield, Chief Building Official
Town of Estes Park, Division of Building Safety
PO Box 1200
Estes Park, CO 80517
Re: Estes Valley Library
Upper Level Minor Remodel Project
.c.ruii"lt 00 Ora
(") Y l Y;, a :y
Dear Mr. Birchfield,
Thorp Associates has been asked to review the proposed minor remodel for the upper level of the Library. Attached is an
I1x17 plan provided by the Library and contractor of the work to be done. The work includes the construction of two
small Interview Rooms, along the west wall backed up to the west stair well; and the construction of a wall and double
doors across the opening between the west and south "wings" of the upper level. The south wing of the upper level is to
be changed in use from "reading area and stacks" to a "classroom".
We have reviewed this plan with respect the drawings and code analysis we performed for the building originally in 1989
and then for the upper level expansion in 1998. Attached is a copy of the Permit Information from the title sheet of the
1998 drawings. That code analysis was based on the 1997 Uniform Building Code, but is clearly translatable to the
current 2009 International Building Code language.
The Occupancy Classification for the building is Group A-3 "Libraries" (IBC Section 303). The Construction is Type V B
"any material permitted by code" (formerly Type V-N). The work proposed is classified by the International Existing
Building Code as Alteration -Level 2 because it includes "reconfiguration of space (and) the addition (of) door(s)" (IEBC
Section 404.1).
The work proposed does not effect floor area or other building limitations. It does however increase the occupant Toad.
The south wing of the upper level is 560 sf. Used as reading areas and stacks, the occupant load of the space is currently 9
people. When changed to a classroom, the occupant load increases to 28 people (IBC Table 1004.1.1),
The increased occupant load is not enough to require that the new classroom have more than one exit (IBC Table 1015.1),
or that the upper level of building have more than the two exits provided (IBC Section 1015.1.1). Nor are any of the exit
widths provided exceeded by the increased occupant load. With the new construction, previously installed exit signs will
be obscured from some vantages, so the attached plan illustrates two new exit signs. One within the new classroom and
one on the south wall of the west wing pointing toward the west exit stair. These signs are to be self illuminated
complying with IBC Section 1011 and include directional lighting complying with IBC Sections 1006.
The new set of double doors is to be push-pull type with no locking hardware, The doors to the Interview Rooms will be
latching with lever -type handles, but will not be locking. Clearances around doors are adequate for maneuvering space
required for handicap accessibility per ICC"/ANSI A 117.1.
The current total occupant Toad for the building is 267 people, With the change of the upper level south wing to a
classroom, the total will become 286. This is a 7% increase in total, and a 16% increase for the upper
level. Being less than 20%, the number of plumbing fixtures required does not need to be
adjusted (IEBC Section 710).
We believe that the upper level remodel work proposed by the attached drawing and
described herein will be in compliance with the 2009 IEBC and IBC for life safety and
with ANSI A117.1 for accessibility. Please call if you have any questions or concerns.
Respectfully submitted,
Joseph E Calvin, ALA, Vice President
THORP ASSOCIATES, P.C., Architects and Planners
copy: Eric Kilbourn and Byron Francis - B&E Builders
Mark Riffle .. Estes Valley Library District
131 Stanley Ave, Suite 100 PO Box 129 • Estes Park, CO 80517 • 970 586 9528 • Fax 4145
• rww.thorpa s c.conn
Per
1997 Uniform 13u1lis1Ing Gocic Rcvlcw
occupAricy CLASSIFICATION
1. FLOOR AREA
a. Lower Lcvel Arca
b. U_pner Level Arca
c. To--;a1 Arca
2 OCCUPANT LOAD (Tablc 10A)
a. Lower Level
1. Meeting Rooms
ii. Library Reading Arca
iii. Library Stack Arca
iv. Offices
v Total Lower Level
b. Upper Level
Mccting Rooms
II. Library Reading Arca
iii. Library Stack Arca
iv. Off iccs
v. 1Tertal Upper Lcvcl
c. Total Occupart4,oad'i
" 3. o6c.upA,,rit- y imm-ouft
a. k IV; VatlOCCUparilf:iancy:
2-hr Arca SeparatiOn)is required
ACCCSOryn
Library and Municipaiii3uiiding
, , 0140'
137----tyrt-Ittew TION
1. Construction Typci Typc v-
2.
Assembly Rcquircments for 1( ypc
a (Scaring Wails - exterior
b, [Scaring Walls - intcrior
c. Nonbcaring Walls - exterior
d Structural Frame
c. Partitions - Permanent
F. Shaft enclosures
g. rloors and rloor-Gciling5
h. Roofs and Roof-Ccilings
1.extcrior Doors and Windows
Stairway Construct ion
C. LOCATION ON PROPERTY
1. To North Property Linc
2. To east Property Linc
3. South to Curb
4 Wcst to Municipal Building
D. ALLO1A1A1312 FLOOR AREA
1 basic Allowablc Arca (Tab ic 513)
a 8,000 sf For Group
b. 6,000 sf For Group A-3 (01cet(rq Rooms)
6,000 x 0.92 + 6,000 x 0,08 = -7,840 sf
2. Opcn on Thrcc Sidcs (OOY. incrcase. (505) 15,650 sf
3, Spr1nkicr System is not raciMrcd,
4 for more than onc: story, the: arca may b tw this allowable.
Hcia-i'T Arto NUMER or STORIES (Table 513)
Na>linurr (ht40i 0"
2Max Ournbcr oF 'f.itork:5 2 for Group
11,110 sf
7,415 sf
18,525 sf
15 sf
50 sf
100 sf
100 sF
15 sf
50 sF
100 sF
100 sF
/
person
person
person
person
person
person
person
person
6
A-3 (For
between
V-N (Table
Mont
[lore
None
None
Nonc
1-hr
Nonc
Mont
900 sf
1235 sf
5,157 sF
1,320 sf
652 sf
800 sf
1592 sF
2,450 sf
n
60 occupants
25
52
14
151
29 occupants
57
16
(6
116
267
Meeting Rooms)
6-A)
Not permitted wftNn 5', protected
Icss than i01 11/A (Table 5A)
ron-combustibtc
>20° Or"
55'-0's
aterials Aft gend
AOO Co
A01 Coc
A1O Mai
All Up:
Der
Al2 Mai
A13 Upr
A14 Mai
• Equ
A15 Up:
Equ
A16 Mai
A17 Upi
A18 Roc
A20 Roc
Sch
A30 Ext€
A31 Exte
A40 Buil(
A41 Wal
A42 Wal
A50 Det
A60 lnte
Res
SI
S2
S3
Sec
Roc
M0.1 Me(
Not
MC).2 Me(
Undlistt„,,o-br d
COMMERCIAL PERMIT INSPECTION RECORD
JOB ADDRESS ,33.E _- . 8-4XHO/r E PERMIT # 6+ 93-9
CONST. TYPEV 6 OCCUPANCY LOAD24 7 SPRINKLER._ At
CONTRACTOR €Y', - Qt//L DEELS PHONE 9 70 - Z Z7
OCCUPANCY GROUP ,4 ` 3
OWNER ZI itga,K Y
DESCRIPTION OF WORK
THIS CARD MUST BE POSTED AND VISIBLE FROM THE FRONT OF JOBSITE AND MUST BE PROTECTED WITH
PLASTIC OR OTHER WATERPROOF MATERIAL.
SETBACKS
FOOTING
FOUNDATION
UFFER GROUND
DRAIN PIPE/RADON
DAMP PROOFING/WATER PROOFING (FOUNDATION BASEMENT WALLS)
PLUMBING UNDERGROUND (INSIDE BUILDING)
SEWER SERVICE & UNDERGROUND OUTSIDE OF BUILDING (SAN DIST,,,,,_
WATER SERVICE
ROUGH MECHANICAL
ROUGH PLUMBING
ROUGH GAS
FIREPLACE
ROUGH ELECTRIC (STATE INSP.
ROUGH BUILDNG
ROOF IN PROGRESS
ROUGH INSULATION
DRYWALL
FINAL
EXT WALLS VENEER & OPENINGS
COUNTY HEALTH INSP (SEPTICFOOD/ALCOHOL SERVICE. DAYCARE)
PLANNING DEPT
PUBLIC WORKS DEPT
FIRE DEPARTMENT
ELEVATOR,STATE CERT INSP.)_.._.,
SPRINKLER (STATE CERTIINSP)......
ACCESSIBILITY (HANDICAP)
FINAL ELECTRIC (STATE INSP.')
FINAL TOWN WATER DEPT. METERTALL"
FINAL JOB COMPLETED
ALL INSPECTIONS MUST BE "%EQUI ST RY CALLINfi 577-3731 Y 4:00 P.Ni. T E
PRECEDING WO K DAY. INSPECTIONS CAN ONL. 11IE °' UES t ;t;`; 11IY T :l C NT ACT
ORMI T E WO TO ;; INS 1' CTEALL INSP C `11O.N RE U STS ;%t IST INC E
THE CNTU CT !%'S NAME AN T , N LICENSEEr , , CID A ESS,
SPECTION(S), AND PEIT NU ! 11I,El .. FAILURE T COMPLY WIT; A" ' OF
EQUI ;(M:E"NTS MAY LAY IN PECTIN'S.
'siai-ver 6tduwuiklimsgrtdu,p04tAdmwspetauon forms.„ etc\corn
rd dor