Loading...
HomeMy WebLinkAboutDOCUMENT Fire Support System 3501 Fall River RdHOOD 7’0”I I DUCK 10”X14”I GAS VALVE 4r e SIreeezi 9•••* e a REMOTE PULL STATION 24”X 24” Griddle 3fi1124 65 Range ANSIJL P102 3 GALLON SYSTEM TOTAL FLOW POINTS 11 MAX COVERAGE NOZZLE FLOW POINTS NOZZLE PLACEMENT Duct 1W 1 Duct Intertace Plenum iN 1 EverylO’ Griddle 1 N 1 35”-40” BSRange 3-iN 3 30”-40” Hill CountryjDella Terra 3501 FaIl River Rd. Estes Park.Co. PIPE:3/*”CLACK SCHEDULE 40 112”EMT CONDUIT—CORNER PULLEY EACH CHANGE OF DIRECTION REMOTE PULL STATION LOCATED IN THE PATH OF EXIT GAS VALVE TO SHUT DOWN GAS SUPPLY UPON ACTIVATION MICRO SWITCH SUPPLIED TO CONTROL ALL ELECTRICAL FUNCTIONS *EXHAUST FAN MUST STAY ON OR COME ONIF OFF MAKE UP AIR MUST SHUT DOWN ALL ELECTRICAL APPLIANCES AND OUTLETS UNDERTHE HOOD MUST SHUTDOWN INTERCONNECT FIRE ALARM PANEL IF EXISTING INSTALLATION DATE: B THIS SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH NFPA 17*, UL 300 STANDARDS,AND ALL MANUFACTURE SPECIFICATIONS INSTALLER (5): DRAWING DATE 07103108 DRAWN BY SILLY RAY HENDERSON Sentry Fire &Safety Inc. 1294 S.Inca St. Denver,Co.80223 [303)294-0708 SYSTEM DESN The ANSUL R 102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli ances and hood and duct configurations ]he design information jisteci )ij this section deals with the.Iimitaltonsandpa r a r n e t è r s of this pa engineered system Those individuals responsible for the desigh of the R-102 ‘stem mutbe trained and hold a current ANSUL cartitteate in an R 102 training programTheFt102andthePIRANHAsystemsusecompatible agents arid components,therefore,thy may b used tbeter icr óookin ••-appliañc,hood,and dUct protctloñ.Th primar’ANSUL AUTOMAN Raleae can be either áh R1O or PIRANHA ANSUL AUTOMANRelease and can actuaIe up to Iwo additional •R1 02 or PIRANI-fARegul a f e d AlUalors.In systehrs ulilizing a .101 remote release,an’combination of the maimuth number of •regulated actuators canba used. .• .Both systems mUst actuató simultaneously.. .:Each system must b’edesgned and installed per its appropri •ate manual. •:-V,Adjacent appliances requiring protection must he protected with the ame pe ofsysIem,either 5-102 o PIRANHA, •- •unless the cenler-to-centec spacing between the adjaôent R-102 and PIRANHA nozzles is no less than 36 inches.When appliances are protectd with R-10?nozzleS,the hood and.connectlng duct abth’e those appJincps cannot be pro tooted with PIRANHA nozzfos.V V V • V Mixing syslems in a common plenum is not allowed. • V VDne.oi tha.keyetements for restauraht fire protection is a correct •‘-.yslem desigt his sac V V —ze’acamertt5equiremen t s , Tank Quantity Requirements,Actu ation and Expetiant Gas Line Requirements,Distribution Piping V RèqUicemenLs Detection System Requirements Mental Pull Sla V lion Requirements,tvtechanicai Gas Jatve quverretrits,EleCtri cal Gas Valve Requirwnents,Electrical Switch Requiraments arid Pressure Switch Requirements.Each of these sections must be completed balore allempling any nsiallation.Sysfam design sketches should be made ci all aspects ol design for reference V V during installation. V •NOZZLE PLACEMENT REQUIREMENTS VVV V This sectIon gives guidelines ton nozzle type,positioning,and uant1ty for ductplenum,and individual appliance pron3ction This •setion must be completed bolore deterrntning tank nilanlily and piping requirements. V Duct Protection —Single Nozzlu All duct protectIon Is UL listed without limliation of maximum duct length (uql!mlted length).This Includes all varieties of ductwcirks both horizontal and vertical Including ducts that run at angles to the horizontal and ducts with dijeclional bends.- V ThaR-102 systóm uses diflerent duct nozzles depençlii-g on the size of duct.bing protected. V • : -: V SECTION IV —SYSTEM DESIGN•UL-EX.34o. V V V ULGCE747 V V V;V Pae4-l 41-OS IREV6 GENERAL INFORMATION 1 Nozzles must be located 2 8 in (5 20 cm)into tite center of the duct opening discharging up Sea Figure 1 m) -- V •V -VVF1GURE1V•.• - V --- V -.:•2 In Installations where a UL listed damper assembly is employed,the duct nozla can be Instatlp.d bpyoed tha&in. (20 pin)maximum,tO a point just beyond4ha damper assem bly that will nat lnterterewith the damper.Exceeding the mexi— -.V : mum of 8 in.(20 cm)in this way will no void the ULlistlng of V the systeri,V V V V V ••• V V V3:PrevIously lisled tloi numbCr and 5 (low number duct pro-V tection detailed in earlier published manubl,Part No. 4V 8O87Z=__an also stiII.V DUCT SIZES UPTO 50 IN.(127 cm)• V LPERIMETERI I6V1NV (41 cm)DIAMETER One 1W nozzle (Part No.419336)=one flow number50in.(127 cm>perimeter maximum•16 In.(41 cm)diameter maximum •DUCT SIZES UP TO 100 lN.(254àm)V• V • ••:•-. LR1METERI32 IN (81 3cm)DIAMETERQj2WNozzle(Prt No.419337)two flow numbers•100 in.(254 cm)perimeter maximum -32 in.(81.3cm)diameter maximum ---•A 2WH nozzle (Part No.78078)must be substituted for a 2W •- nozzle for any installation using Option 2 01 the 1.5 gallon sy- tern coverage (duct and plenum protection only).A2WH nozzle islirjilted to a maximum of 75 in.(190 cm)perimeter or rnaxi mum diameter of 24 in.(61 cm)of coverage - V • V The chart below shows,the maximum Pr9tectVion available frorñ - each duct nozzle - Part 3 0 Gallon 1 5 Gallon ttton No System System2WNozzle419337MaxImum Aaximum-100 in (254 cm)100 in 54 cm)Perimeter Perimeter1WNozzle419336Maximum Maximum50in(127 cm)50 in (127 cm) V • .-:.•.Perimeter ..Perimeter • •-V-V.••V ••••VVV •V:• -V • V V • V ••V •‘ C * f •1:i.IANSUi tqca R-102 RESTAURANT SYSTEM V NOZZLE COVERAGEJOVERLAPPING SUMMARY SHEET • V Width Length Multiple Nozzle Multiple Nozzle Mm.Max.•V Nozzle Flow (In)(In)w&Drip Board w/Drip Board Nozzle Hi.Nozzle Hi.Appliance V Type Points Max.Side Max Side Area In2 Area In2 (in)(in)Fryers without drip boards 230/290*2 14 15 ——V 27/13 47/16SplitorNoSplitVat2451290214/14 1)2 15/14 ——20/16-27/27Fryerswithoutdripboards2902191/2 19 —V —13 16Non-Split Vat (ONLY)3N 3 19 1/2 19 ——21 34. V 3N 3 18 18 ——25 35Fryerswithdripboards230/290*2 14 21 210 294 27/13 47/161.0W PFOXZflIt)f Split or No Split Vat’245/290*2 14/14 1/2 21/26 1/2 210/203 -294/384.2 20/16 27/27Fryerswithdripboards’290 2 19.5 25 318 V 370.5 495 13 16Non-Spilt Vat(ONLY)3N 3 19.5 253)8 370.5 495 21 34V 3N 3 18 324 497 25 35VflItSkillet/Braising Pan2 Coverage limitation are based on fiyer sizes including the drip boards.Exception:Tilt Skillets and Braising may exceed the maximum of 6 ft2 1 Longest Side Max.Area Sq.In. V -Range iN 1 12 32 384 —30 -40 •: V Without back shelf iF 1 12 28 336 —30 50V With back shelt iF 1 12 28 V 336 —V VV 4 —V 245 2 24 28 ——40.50VWithoutbackshelf26022432768— V 40WithbackshelF26021232384—30__—V 40_—2x290 4 36 28 1008 —15 20Griddle1N/1NSS 1 36 30 ——35 40•• V V 290 2 30 24 ——30_—50V• 260 2 48 30 ——30 50•V 290 2 48 30 ——20 30 2120 2 48 30 ——10 20ChainBroiler’2 x 1W 2 34 30 ——10 26(Overhead Protection) Chain Broiler 2 x iN 2 31 43 ——V Front edge:1-3 in.(Horizontal Protection) above the chainCharBroilerGas-Radiant iN/i NSS 1 24 36 ——15 40Electric1N/i NSS 1 20 34 ——20 —_50Lava-Rock 1N/1NSS 1 13 24 ——18 35NaturalCharcxrai’1N/1NSS 1 12 24 —18 40Lava-Rock or Natural Char coals 3N 3 24 30 ——14 40WoodFueled’3N 3 24 30 ——14 40UprightBroiler2x1)2N 1 30 32.5 Front edge:Salamander Broiler 2 x 1/2N 1 30 32.5 ——above the grate iN 1 16 — ——j —.iN nozzle location to be on the vertical edge 61012 lfl.in front and 0 to 12 in.above the top of broilerInternalChamber1N11629——6-12 in.above either endWok3.75 to 8 in deep 260 2 14 in.1030 in.diameter ——35 45:31o6 in deep iN/i NSS 1 11 in.1o24 in.diameter ——-30 40 -‘For multiple nozzle protection of single tryers,see detarled information on pages 4-6 to 4-11 of manual. V 2 See Figure 1 for nozzle location. V V Minimum chain broiler exhaust opening —12 in x 12 in (31 cmx 31 cm),and not less than 60%of internal broiler size. V 4 in (102 mm)maximum fuel depth. V ‘6 in (15 cm)maximum fuel depth. -‘Shell can overhang bumer(s)by maximum 0111 in (28 cm)and height limitation 0120 in (51 cia)from bottom of lowest part of shell to the top of burner grateV7Shelfcanoverhangburner(s)by maximum ot 11 in (28 cm)and height limitation 0118 lO (46 cm)from bottom of lowest part of shelf to the ton of h,,ror nrut.•I nuj Prnvi,,,t. R-102 RESTAURANT SYSTEMNOZZLECOVERAGE/OVERLAPPING SUMMARY SHEET Width Length Nozzle Placement Mm.Nozzle Flow (In)(In)(See Manual HeightPlenumTypePointsMaxSideMax.Side for More Detail)(In)Horizontal Protection Single Bank iN 1 48 120 0 in—S in from end of plenum 2PerpendicularProtectionSingleBank1W14848SeeManualformoredetailIHorizontalProtectionV-Bank 2 x 1N 2 48 120 0 in—S in from end of plenum 2HorizontalProtectionV-Bank 1W 1 48 72 0 in—S in from erd of plenum 1/3PerpendicularProtectionV-Bank 1W 1 48 48 See Manual for more detail Nozzle Placement DuctNozzleFlowPerimeterDiameter(See Manual LengthDuctTypePoints(In)(In)for More Detail)(In)Single Nozzle 1 Flow Nozzle 1W 1 50 16 See Manual for more detail UnlimitedSingleNozzle2FlowNozzle2W2100317/8 See Manual for more detail UnlimitedMultipleNozzle2W+1W 3 135 48 See Manual for more detail UnlimitedMultiple2WNozzle2W—>135 >135 See Manual for more detail Unlimited :LIANSUL1 } tqcu R-102 OVERLAPPING PROTECTION The 245 nozzle,Part No.419340,must be used for “end of zone”protection,‘and the 260 nozzle,Part No.419341,must be used for “zone”protection. COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN Appliance Type Fryer Griddle Range Wok,Maximum Wok,Minimum Braising Pan/Tilt Skillet Lava Rock Char-Broiler Charcoal Broiler Mesquite Wood Broiler Gas Radiant Char-Broiler Electric Char-Broiler Maximum Cooking Hazard 34 in (864 mm)Deep x 5.8 ft2 (.54 sq2) 30 in (762 mm)Deep x Unlimited Length 30 in (762 mm)Deep x Unlimited Length 30 in (762 mm)Diameter x 8 in (203 mm)Deep 11 in (279 mm)Diameter x 3 in (76 mm)Deep 34 in (864 mm)Deep x Unlimited Length 26 in (660 mm)Deep x Unlimited Length 30 in (762 mm)Deep x Unlimited Length (4 in (102 mm)Maximum Fuel Depth) 30 in.(762 mm)Deep x Unlimited Length (6 in (152 mm)Maximum Fuel Depth) 36 in (914 mm)Deep x Unlimited Length 34 in (864 mm)Deep x Unlimited Length Illi4_.4 0-12 IN I 10-305 mm)I’ 40-45 IN I (1.1.lm) 006521 FIGURE 1 ZONE CENTER LINE See Figure 1 for noz.zle location. Note:Group protection option is required for appliances on either side of an appliance(s)using dedicated protection —see manual br details. Overlapping System Piping Limitations Total Max.3/8 in Max.MaximumSystemFlowPipeNo.of Elevation CartridgeSizeNumbersLengthElbowsReSize3Gallon675ft2510ItLT-30-R(22.9 m)(3.1 m) 6 Gallon 12 75 ft 25 10 ft DoubleManifolded(22.9 m)(3.1 m)Tank 50 ft (15.2 m)maximum pipe from first to last nozzle. 50 ft (15.2 m)maximum pipe after the split on a split system. DETECTION SYSTEM REQUIREMENTS SECTION IV —SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-53 4-1-06 REV.3 Once the fire suppression system design has been determined,adetectionsystemdesignmustbecompleted.This section containsguidelinesandlimitationsfordetectionsysteminstallation. Detector Identification The two types of detectors are distinguished from each other bytheirlocationinthedetectionsystem. 1.The Terminal Detector (Part No.56838,15375,or 417368)isthelastinaseriesofdetectors,or the only detector used in asingle-detector system.This detector is thus named becauseitisatthepointatwhichthewireropeends,or ‘erminates’ 2.A Series Detector (Part No.56837,15373,or 417369)is anydetectorlocatedin-line between the regulated release mechanismandtheterminaldetector. Detector/Pulley Elbow Quantity The quantity of detectors used in the system will vary dependingonthestyleofdetectorused. 1.Conduit runs,pulley elbows,and number of detectors per systemmustbewithintheapprovedsystemguidelines.The followingrequirementsmustnotbeexceeded: Clip on Style 12 18Detector Hinge Style 5 Detector Scissors Style 15 20Detector 2.If hinge style detectors are mixed in a system with either clip-on or scissor style,4 series and 1 terminal is the maximumnumberallowed.If clip-on style are mixed with scissor style,the maximum allowed is 11 series and 1 terminal. NOTICE When using the “clip-on”style detector,the terminaldetectormayusethe‘hinged”stylemountingbracketwiththe“clip-on”style linkage.This is only allowed with the terminal detector. No other linkages are allowed to be mixedwithotherbrackets.When using this option,the total number of “clip-on”style detectors (11seriesand1terminal)is still allowed. 3.If hinge style detectors are mixed in a system with either clip-on or scissor style,the maximum length of wire rope must notexceed103ft.(31.4 m)and the maximum number of pulleyelbowsmustnotexceed8.If clip-on style are mixed with scissorstyle,the maximum length of wire rope must not exceed125ft.(3.81 m)and the maximum number of pulley elbowsmustnotexceed18. 4.If the hazard requires more than 15 detectors,up to five 101RemoteReleases(Part No.32381)can be used for systemactuation.Each 101 remote release allows the use of a maximumof15“scissor”style detectors (14 series and 1 terminal)for a total of 75 detectors if needed. Detector Placement Requirements EXHAUST DUCTS Each exhaust duct must have at least one detector installed in theductentrance,located in the airstream of the cooking vapors,or atamaximumof20ft.(6.1 m)into the duct opening.See Figure 98. NOTICE When gas appliances are used and the fluegasesfromtheburnerareexhaustedintothe dLict,the detector must be kept out of the airstreamoftheseexhaustgases.These gasescanbeveryhotandcouldactuatethesystemunnecessarily. Duct openings that are long and narrow or largeenoughtorequiremultipleductnozzlesmayrequireadditionaldetectors. ELECTROSTATIC PRECIPITATOR If an electrostatic precipitator is located at or near the base of theexhaustduct,it is necessary to locate a detector below the precipitator,at the base of the duct,and also locate one in the duct,lust above the precipitator.See Figure 99. When installing the detector bracket and system conduit,makecertaintheydonotinterferewiththeoperationoftheprecipitator. Maximum Number of Detectors per System Maximum Number of Elbows per System Maximum Length of 1/2 in.Conduit per System 125 ft.(38.1 m) 103 ft.(31.3 m) 150 ft.(45.7 m) 8 FIGURE 98 00027; Note:On secondary filtration units utilizing multiple filterstages/media,contact Ansul Technical Services tor instructions. FIGURE 99 -I 2.The total Jengihof all branch lines must not exced 36 It.(10.9 ni).Sea Fiure 93. 3.Usa a 3/S in.union to connect the lank adaptor to.the 318 In.supply line. Pipe Size 3)8 ill.Lrnmiog.ll1 40 lt. •.(l2V2m) Maximum Rise a h. (1.8m) Maximum 90 9Elbows Maximum Tees Maximum Flow 11Numbers 3/8 in.3/8 in. •VV •V 311.V Zft.._VV V(2.1 n-f)(I .2 m) 411 2tt.(12 in)(.6 in) 4 4 2 2 4 2 Appliance EraacliiJne 3/8 in...V.. V 12 ft. (3.7 in) 2 It. (.6 m) 6 4 4 ‘EXcpiiana: .... V 1.IWUIVfr (12)&w ala aliowad in any cna iaik kx Iii ad lo0lin l(OlbL.-IlOn o(1i5 ••• V • 2.Twuivu (12)Ilow iaers ale allowed with any ono lank uawaj aofy lwOVffan,appannce nthjoa.-. 3V Twtalve (12)ilow iund>cn osu allowed wiu any iwin I,uiwg ordy ltuaaIIc.w a diar.ce noala. SpuciaJ irialouceons: . V1.Twwivu (12)151w urAaara ala a&rnud wIran but (.1)Da.ar IlJuakwa Gil Ga-i Fryut ara proieoiecj al low p(aalrnily 5$&3XJW11 h F)9u18 S.041 Pa.e 4-32.The dIoiarge y44-ig mul as shown Si Fejuio 59 oi PNIO 432. V .Fut certain McDonalds appficiuu,is.II 5 flow o Ihars ass aluweri when aals a conl lruaIion of one (1)2W duct nozzle one (I)112N lacfrslali p lpilalor nozzia one (I)IN plenusa izzala.el oLe f4f lw-flow pILaaics,ns.jaa Cosriazi Ansi Appitaij.Esisjireerfrv5 Depall.i.i Si.aaldiwsel Ink mafia.. V V V V VV ;‘VV •V•:..VSECTIONVIV SYSTEMbEsiGNULEX347(J ULC CEx747 PaQG 4 4941O6REV4DtiRIBUTl0NPIPINGREQUIREMENTS(Continued)Distribution Piping tequlrements —3 0 Galio SystemIThemaximumlengthbetweenthehiarlohthefirstbranch lIne suppLy and the start of the last branch line must no(eceed 24 ft TCE V - -(7.3 m).When the supply,line 1$split,(he combined total of V -•• VV --•__.. .-•--.-: both lags of the supply one (from the stafl oh the first branchlineIdthestartofthelastbranchtine)must riot exceed 24 11 (73 m)Sea Figure 93 i:T ç \V LlEMUSrNor -EXCEED 24 FT (7 3 m) - .4.A naxlmum of two nozzle re lhow&i per duct branch line. V V V V.: V V V 5.The requlrements.oi (he following table must not ba exceeded: V .V V VVV 2WNO.E - IN 4022LE 230 NO/ 1N NOLZLE(EflR&NrH LINE INBOLD)CUMIJ1j4ED i.ENOflI 1)31ST 00102 V • V NOT ExcEBo 3a Fr.(lOOse)V V VJ FiGURE 93 Duct Plenum dLd110h .L(nrt &anch.Lini SECTION IV —SYSTEM DESIGNUI..EX 347o ULC C2x747 Page 4 13 —4106 REV5mangeProt1FlowNozzle When this type of hazard is equipped with a back shelf located The R io system uses five dierent nOzle5 for tne protect;00 above the range top o protection Options are available ranges Two of the design Opliofl require a one flow nozzle and requires a IF nozzle Part No 419333 and the other option three of the design options require O flow nozzles requires a 260 nozzle Pafl No 419341Option1lFNozzjeWhenUSingthalFnoe for range profe A 13 in (33 cm)diameter wok pan is the largest tion with or without back Shell the maximum length of wok Size that can be Protected on ranges the burner grates being protecl must not exceed en Protecting hot t ranges the ntire :,.“28 (7t.cm)and the makimum area,of the urner cocking sudace must be protected grates must not exceed 336 sq Ia (2i68 sq cm)SeaFigure27.for nozzle Iocabon detls .. Range Protectjo0 (1 Flow Nozzle)- Single and multiple burner ranges can be profec ted using a IN SHELF BURNE flOZa Part No 419335 The nozzle tip is stamped with IN OVA XiMuM OF i cating that this is a one-flow nozzle and must be counted as one ,.......:.‘ flow number jenusInthisnozzleforrangeprotectithemaximumlength I of the burnarates being proTected with a single nozzle must not 40 48 IN (Si ) In.(81 cm)and the maxjrnu area of The.Jrne?grates .(102. kliNiUiJM . must not exceed 384 sq.In.(247 sq.cm)per nozzleWhenProtectingarange,the 1Nnozzje must be located a majc :‘ mum of 10 in.(25.4 cm)from each burner grate centerline andmustbeimedatthecenterofthecookingsurfaceSeeFigue26..14 iN. i35.s cm)‘ FIGURE 26 IZiN. MAXiMU cENrmUNeIFNOZ2LELOCATEDERFHOEDGE OF BURN GRATE AND 50 NOZ flP AR PARALLEL Wi 8UR GRATE FRONT TO REcTERLiNEANOSHAUBEAiMEDATTHCENTEROFThCDOK)Nn SUflF FIGURE27 tO022Option2:260 Nozzle:When using the 260 nozzle for range protectionwithorwithoutbacksheEtthemaximumlengthofburnergratesbeingprotectedmustnotexceed32in.(81 cm)and the maximum area of the burnergratesmustnotexceed384sq.In.(2477 sq.cm).Nozzle must be located on the front edge of the burnergratesandaimedatapoint10in.(25 cm)from thebackedgeoftheburnergratesNozzlemustbemount.ad 30 to 40 in.(76 to 102 cm)above the hazard Surface.See Figure 28. 250 NOLE SHELF CAN OVEIjIANG A MAXIMUM OF II IN.(28 cm; AiMIt4G POINT .,.‘.‘ , FIGURE 28 Griddle Protection 1-Flow Nozzle The IR-102 system uses four different nozzles for the protection ofgrlddles.One of the applications requires a i-flow nozzle andthreeoftheapplicationsrequirea2-flow nozzle,High Proximity Appllcatiom 35 In.to 40 In.(89 In 102 cm)abovethecookingsurface. This high Proximity application uses lIie IN nDzle,Part No.419335. The nozzle tip is stamped with 1N indicating this is a erie-flow nozzleandmustbecountedasoneflownumber. One IN nozzle will protect a maximum cooking area of 1080 sq.in.(6968 sq.cm)with the maximum longest skte of 36 in.(91 cm).When using this nozzle for griddle protection,the nozzle must bepositionedalongthecookingsurfaceperimeterto.a maximum of2in.(5 cm)inside the penimetal,and aimed to the midpoint of the-cooking surface.See Figure 35 and 36. NOTICE When using this type of griddle protection,only5flownumbersareallowedona1.5 gallon systemandonly11flownumbersareallowedona3gallonsystem. SECTION IV —SYSTEM DESIGNULEX.3470 ULC CEx747 Page 4-17 10-1-02 REV5 NOZZLE LOCATION Li —2 IN.(0 —5 cn) INSIDE PERIMETER OF COOKING SURFACE /q1+40 IN. (102 Liin( MAXIMuM hEIGhT /4IN.i ETlP cmii f.4INIMU I hIEIGIIT OFIN NOZZLE Ti / EDGE OF — cO0KINI sUAFACI 4 FIGURE 36 LiOC24 4- COOKING SURFACE r——,I..L_Lj iN NOZZLE LOCAFED ALONG ANY SIDE OF GRIUDI.E SURFACEWIThIN0—2 IN.10-5 cnII OFCOOKINGSURFACEEDGENUZZL.EMUSTEAIMEDArMIDPOINTOPCOOKINGSURFACE I COOKING SURFACE KUGE FIGURE 35 U’4’4, TOTAL SYSTEM SECTION II—SYSTEM DESCRIPTION UL EX.3470 ULC CEx747 Page 2-1 3-1-04 REV.3 There are three types of R-102 Restaurant Fire SuppressionSystems: 1.Single-tank System 2.Double-tank System 3.Multiple-tank System The type of system required for the particular installation will bedeterminedthroughtheguidelinescoveredinSystemDesign.”Additional equipment which may be required to complete the systemdesignisexplainedinthe“System Components”section.Additional devices covered are:remote manual pull stations,mechanical and electrical gas shut-off valves,electrical switches,and pressure switches. Single-Tank System The R-102 single-tank system is available with a stainless steelenclosureandconsistsof: 1.ANSUL AUTOMAN Regulated Release Assembly (ElectricalorMechanical) 2.Nitrogen Cartridge and/or Carbon Dioxide Cartridge 3.ANSULEX Low pH Liquid Fire Suppressant 4.Discharge Nozzles 5.Detection Components 6.Additional Devices (As Required) The regulated release assembly contains the regulated releasemechanism,agent tank,expellant gas hose for agent tank hookup,and enclosure knockouts to facilitate installing detection systemandadditionalequipment.Refer to “System Components”sectionforindividualcomponentdescriptions. Double-Tank System The R-102 double-tank system is available with a stainless steelenclosureandconsistsof: 1.ANSUL AUTOMAN Regulated Release Assembly (ElectricalorMechanical) 2.Nitrogen Cartridge and/or Carbon Dioxide Cartridge 3.ANSULEX Low pH Liquid Fire Suppressant 4.Enclosure or Bracket Assembly 5.Discharge Nozzles 6.Detection Components 7.Additional Devices (As Required) The regulated release assembly contains the regulated releasemechanism,agent tank,expellant gas hose for agent tank hookup,and enclosure knockouts to facilitate installing expellant piping,detection system,and additional equipment. The enclosure or bracket assembly is mounted separately butwithintheguidelinesoftheregulatedreleaseassemblyexpellantgaspipingrequirementstoensuresimultaneousactuationofthesystem.Refer to “System Components”section for individual componentdescriptions. FIGURE 2 Oc’13” FIGURE 1 000133 SECTION I —GENERAL )NIORMATIONLJLEX3470ULCCEx747Page114106REV4 DESIGN AND APP1JCATION £EFlNrnON OF TERMS The ANSUL R 102 Restaurant Fire Suppression System is Actuation Gas Line Piping froni the ANSUL AtJTOMAN designed to provide fire protection for restaurant cooking appii Flegulated Riease Assembly which supplies nitrogen or carbon aneas,hoods and ducts it is a pre engineered group of mechan d1oxde k the Regulated Actuator Assembly for multiple tank sys Ical and electrical components for installation by an authorized tern actollonAUTOMANregulatedreleaseassemblyAgentTanLA pressure vessel containing the liquid agent ad release mechanism and a liquid agent storage tank housed ANSUL AUTOMAN Regulated Release Assembly (Electrical) within a single enclosure Nozzles detectors rarlr1dges liquid An assembly which contains the regulated release mechanism, agent fusible links pulley teas and pulley elbows are spplied ajent lank (ordered separately)expeitint gas hose solenoid and separate packages in the quantities needed for each fire suppres electric switc.h within a metal enclosure The enclosure contains ston system arrangement knockouts to facilitate component hookups The system provides automatic actuation or it can be actuated ANSUL AUTOMAN Regulated Release Assembly (Mechani manually through a remote manual pull station The system is also cat)An assembly which contains the regulated release macha capable of shutting down appitanres at system actuaop,For psm agent tank (ordered separately)and expeilarit gas hose appliance shutdown requirements refer to the current yesfpi p1 wdhfri metal enclosure The enclosure contaIns knockouts to NFPA 17A Standard For Wet Chemical Extlngulshiiig sysfns”1bihtataeomponent hookup’ and NFPA 96 Standard For Ventilation Control iro Authority Having JurisdictIon The authority having Jurisdiction Protection of Commercial Cooking Operations organization office or Individual responsible for approving Additional equipment includes remote manual pull tallon equipment an installation or a procedure The phrase Authority mechanical and electrical gas valves,pressure switches ani elec I-laying Jurisdiction is used in a broad manner since jurisdictions trical switches for automatic equipment and gas me shut off and ‘approval agencies vary as do their responsibilities Where Accessones can be added such as alarms warning lights,to public safety is primary the authority having jurisdiction may be installations where required a federal state local or other regional department or individual The R 102 system suppresses tire by spraying the pienur area such as a fire chief fire marshal chief of a fire prevention bureau Thhe filters,cooking surfaces,and the exhaust duct systrvitha labor department,health department,building official,electrical predetemined flow rate of ANSULEX Low pH Liquid Fire trjspeclor,Vor others having statutory authority.For insurance pur-. Sdppressant.When the liquid agent is discharged onto’a cooking poses,an insurance company representative may be the author- appliance fire,it coois the grease surface,and reacts whh the lot ity having jurisdiction.in many circumstances the property owner grease (saponification)torming a layer of soap-like iodm on the or his designated agent assumes the rote of the aulhoiity having surface of the tat This layer acts as insulation between the hot (unscliction;at government instaiialtons,the commanding officer grease and the atmosphere,thus helping to prevent the escape of or.departmental official may be the authority having Jurisdiction. combustible vapors. V V slow-Off Cap:A cap which covers the end of the nozzle tip and Exhaust fans in the ventilating system should be tell on.Theforcnd prevents’rease from plugging the nozzle orifice. draft of these tans assists the movement of the liquid eri Branch,Une:The agent distribution piping which extends from the V V through the ventilating system,thus aiding in the fire su r SU I —process— r s a so prov a a cooling ettect In the plenum Bursting Disc A disc installed In the tank adaptor which elimi and duct after the tire suppression system has been discharged.hates thè.siphoning ot the agent up the pipe during extreme tern- The system is UL fisted with or without fan operation. peralurevariations. Cartridge:A sealed,steel pressure vessel containing nitrogen orcarbondioxidegasusedtopressurizetheagenttank.Cooking Appliance:Includes fryers,griddles,ranges,uprightbroilers,chain broilers,natural charcoal brOilers,or char-broilers(electric,,lava rock,gas-radiant,or mesquite). Cooking..Area:Cooking area is defined as the maximum surfacethatrequiresprotection.Each type of appliance has a defined V pking aee.ForV V:pof for a fryer without a dripboard and the maximum cooking area V is the combined Irypot and dripboard for a fryer with a drtpboard. The R-102 Restaurant Fire Suppression System has been tested V V and is listed by Underwriters Laboratories,Inc.as a pre-enginearedsystem.The system is In compliance with ULTestStandard300.These tests require extinguishment of fires whichareInitiatedindeeptatfryers,ranges,griddies,chdr-hroliers,woks,upright broilers,chain-broilers,filters,plenum chambers,hoods,and ducts after pre-toading each appliance with a proscribedamountofcookinggrease.Each fire is allowed to progresstomaximumintensityhetorathefiresuppressionsystemisactuated. V ,V V -Make up or supply air fans,Integral to the exhaust hood(s)being.protected,shall be shut down upon system actuation. ‘V Along with the fire suppression system,the total system designmustIncludehandportablefireextinguisher(s)located within the V cooking/restaurant area that can be used to manually suppres a V fire that may be burning In an unprotected area.Refer to NFPA 10,“Standard For Portable Fire Extingulsher,for additionalinformation. VV•Vj V Conduit Offset Assembly:A pro-formed piece of conduit whichcanbelhstalledbetweentheANSULregulatedreleaseandtheconduit(a allow the wire rope for the detection,gas valve andremotemanualputtstationtobeinstalledinamoreconvenientmanner.V ,,V V -,V Depth:When referring in depth as a linear dimension,it is thehorizontaldimensionmeasuredfromfronttobackoftheapplianceorplenum. 20 iN 15)cm( MAiiMiJM I IN (25cm) MINIMU1A El AS (1.2 m) MAXIMUM VV: SECTION IV —SYSTEM DESIGNULEX3470ULCCEx747Page454-1-06.REV.4PlenumProtection The R-102 system uses the 1W Nozzle (Part No.419336)or the. 1N Nozzle (Part No.419335)for plenum protechon..The 1Wnozzlelipisstampedwith1WandtheiNnozzletipIsstarnped.withIN,Indicating they are one-flow nozzles and must becountél as one flow,number each.When protecting e plenum cha?nber,theentirechamber’must be protected regardless of Iilte length.V....VERTICAL PROTECTION -GENERAL V •Ono 1W flozzle will protect 4 linear feet (1.2 m)at plenum.Themaximum.distance from the end of the hood to the first and last nozzle must be no more than 2 ft.(.6 rn).After the first nozzle any •additional nozzles must be positioned at a maximum of 4 ft.(I .2 rn) •apart down the entire length otth plenurn.Tha plenuñiWidth must .not exceed 4 ft.(1.2 m).(The 1W nozzle can be used on single or V-bank filter arrangements.)See FIgure 6. V V V V 2FT.(V6rn) V V V V V V V MAXIMUM .•. VV V V 4FT.(lV2m)_4.A V V V •.Option 2:Tha lW nozzle must be placed perpendIcular,8-12 in. V (20-30 Cm)from the face of the filter and angled to theV V center at the filter.The’nozzle tIp must be wIthin 2 in.V V (5 cm)from the perpendicular canter line of thatiltar. V V:V•. V See Figure 8. V V V V V V V V V :VV V12)4(3o) V.. V V V VV:.V V /XIMU// BIN.f2ocm) MLN)MUM NOZZLE TIP MusTes WITHIN THIS ANSA V ‘qy HORIZONTAL PROTECTION OPTiON 1 .VVYFIQURE8 V . V fr I— IN NOZZLE—PARt PO.419335—SINGLE BANK PROTECTION VOneiNnozztewllt protect 10 linear feat (3.1 m)of single filter bank plenum.The nozzle(s)must be mounted In the plenum 2 to 4 in. (5 to 10 cm)from the face of the filter,Centered between the filter height dimension,and aimed down the length.The nozzle must be positklned 0-6 in.(0-15 cm)from the end of the hor,d to the tip of the nozzle.See Figure 9 FIGURE 6 OD,flWhenprotectingptenumswiththe1Wnozzle,Iwo options of coverageareavailable: Option 1:The 1W nozzle rhust he on the center line of the singleorbankhirerandpositionedwithin1-20 in.(2.5-51 cm)above the top edge of the filter.SeeFigure7. I FIGURE 9 VVf Z0 IN.(51 cm) NAXIUIJM +VVV. I IN (2 5 cm) MINIMUM FIGURE7.V V V V V V• V V V V V V ,,V :V V