Loading...
HomeMy WebLinkAboutPLAN 10 Wagener Rd Pennington PV System As Built 2019-06-26REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 TITLE SHEET N/A 11" X 17" 001 JMM T101 SHEET INDEX PROJECT PROJECT CONTACTS PROJECT DISCRIPTION OWNER&217$&7 CONTRACTOR DESIGN PROJECT SPECIFICATIONS M4 INDUSTRIES 970.685.1136 02'8/(0$.( 02'(/ 47< ,19(57(50$.(02'(/ 47< :$7767,/7$=,087+.:+<5 $55$< $55$< 727$/ $55$< $55$< PENNINGTON PV SYSTEM 308490480 10 WAGENER ROAD ALLENSPARK CO 80510 CHERYL PENNINGTON 303.747.2761 A.ADKISSON ELECTRIC INC 970.412.1988 2.88 kW GRID TIED, FLUSH, ROOF MOUNTED PV SYSTEM PEIMAR SG360 8 AP SYSTEM YC600 4 2880 26.57 228 3979 2880 3979 03.03.19 30849048PENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 80510 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00PENNINGTON PV SYSTEM10 WAGENER RDALLENSPARK, CO 80510SITE PLAN 1" = 40' 11" X 17" 001 JMM C102 1823 02.15.19 SITE PLAN N UTILITY METER MDP PV AC DISCONNECT PV ARRAY REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 002 ASBUILT 06.26.19PENNINGTON PV SYSTEM10 WAGENER RDALLENSPARK, CO 80510ARRAY LAYOUT 1/8" = 1'-0" 11" X 17" 001 JMM PV103 03.03.19 ARRAY LAYOUT ARRAY NOTES 1. EACH MODULE SHALL BE BONDED TO RACKING IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 2. MODULES SHALL BE INSTALLED IN ACCORDANCE WITH MODULE AND RACKING MANUFACTURER INSTALLATION MANUALS. 3. ARRAY SHALL BE INSTALLED SO NO MODULES ARE ABOVE THE RIDGE LINE ELEVATION. 4. ALL WIRES SHALL BE SECURED AND NOT IN CONTACT WITH THE ROOF SURFACE. A1 A2 A3 A4 A5 A6 A7 A8 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 002 AS BUILT 06.26.19PENNINGTON PV SYSTEM10 WAGENER RDALLENSPARK, CO 80510RACKING LAYOUT 1/8" = 1'-0" 11" X 17" 001 JMM PV204 03.03.19 SHEATHING ROOFING TRUSS PV MODULE ASTM F594 3/8" SERRATED FLANGE NUT 5/16" X 3-1/2 S.S. LAGBOLT STEEL WASHER 3/8 X 1-1/2 STAINLESS UNIRAC 304000C L-FOOT ASTM F593 3/8" - 16 HEX HEAD BOLT UNIRAC SOLARMOUNT BEAM UNIRAC END CLAMP OR MIDCLAMP UNIRAC 1/4"-20 T-BOLT W/ 1/4"-20 ASTM F594 SERRATED FLANGE NUT UNIRAC FLAT FLASHING ATTACHMENT DETAIL WILEY ELECTRONICS WEEB BONDING JUMBER 6.7 UNIRAC SPLICEBAR 303001C (4) #10 X 3/4" STAINLESS STEEL SELF DRILLING SCREWS STANDARD SPLICE DETAIL RIDGE LINE DETAIL RIDGE LINE ELEVATION INSTALLED MODULE (TYP) RACKING LAYOUT RACKING NOTES 1. BONDING IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 2. ALL RACKING COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUAL. 3. ATTACHMENT LOCATIONS ON THIS DRAWING ARE APPROXIMATE. FINAL ADJUSTMENT OF LOCATION MAY BE NECESSARY DEPENDING ON FIELD CONDITIONS. UNIRAC LFOOT/FLASHING (TYP) UNIRAC SM RAIL (TYP) UNIRAC SPLICE (TYP) 2X6 RAFTER (TYP) REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00 002 AS BUILT 06.26.19PENNINGTON PV SYSTEM10 WAGENER RDALLENSPARK, CO 80510ONE LINE 1/8" = 1'-0" 11" X 17" 002 JMM E105 03.03.19 +-+-+- 3 1 4 5 7 1 2 3 4 5 8 YELLOW PLACARD, BLACK LETTERING AT EXISTING METER - "PHOTOVOLTAIC SYSTEM CONNECTED". YELLOW PLACARD, BLACK LETTERING ON FRONT COVER OF MAIN SERVICE PANEL "WARNING: OUTDOOR JUNCTION BOX PANEL BACKFED WITH 20A" PROVIDE 240V, 30A NEMA 3R DISCONNECT. SHALL BE VISIBLE, ACCESSIBLE, LOCKABLE AND LABELED "PV AC DISCONNECT", LOCATED WITHIN 10' OF UTILITY BILLING METER. MICRO INVERTER, SEE TITLE BLOCK FOR SPECIFICATIONS NOTES: FEEDER SCHEDULE #6 BARE AWG GROUND1 APS AC CONNECTOR CABLE 12/2 ROMEX IN ATTIC SPACE 2 3 4 (2) #12 THWN, (1) #12 THWN GRND IN CONDUIT GENERAL NOTES: EXISTING METER 7 SOLAR MODULE, SEE TITLE BLOCK FOR SPECIFICATIONS 8 1 2 3 4 10 EXISTING MDP, 100A BUSS, 100A MAIN BREAKER.10 (1) EQUIPMENT SHALL BE INSTALLED AND LABELED IN ACCORDANCE WITH NEC 690 AND ALL APPLICABLE REQUIREMENTS BY ESTES PARK UTILITIES AND LOCAL AUTHORITY HAVING JURISDICTION. +- STRING A +-+-+- 20A BACK FEED BREAKER, LABELED: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 2 +- REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE 001 PRELIMINARY 00.00.00PENNINGTON PV SYSTEM10 WAGENER RDALLENSPARK, CO 80510BOM PLACARDS 1/8" = 1'-0" 11" X 17" 001 JMM E206 03.03.19 PV AC DISCONNECT 240 VOLTS 30 AMPS WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC SYSTEM CONNECTED AC DISCONNECT BILLING METER 1 4 BACKFEED BREAKER 2 SOLAR BACKFEED INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE THIS PANEL BACKFED 240V 20A MDP 3 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC DISCONNECT (LABEL)4 PLACARDSBILL OF MATERIALS REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D107PENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 8051030849048 03.03.19 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM DPENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 8051030849048 03.03.19 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D309PENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 8051030849048 03.03.19 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D410PENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 8051030849048 03.03.19 REV. NO.DESCRIPTION DATE SHEET NO. DRAWING NAME SCALE REVISIONS M4 INDUSTRIES LLC 938 TAIL WATER DRIVE WINDSOR, CO 80550 970.685.1136 PAPER SIZE REVISION DRAWN BY PROJECT NO. DATE DATASHEET 1/8" = 1'-0" 11" X 17" 001 JMM D511PENNINGTON PV SYSTEM10 WAGENER ROADALLENSPARK CO 8051030849048 03.03.19